Loading...
HomeMy WebLinkAboutPermit B96-0105 - KALCHIK RESIDENCE - GARAGECity of Tukwila C (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: B96 -0105 Type: B -BLDG Category: ASFR Address: 14261 53 AV S Location: Parcel #: 725520 -0215 Zoning: R1.72 Type Const: V -N Gas /Elec: Wetlands: Water: N/A Contractor License No.: TENANT OWNER CONTACT Status: ISSUED Issued: 05/03/1996 Expires: 10/30/1996 Type of Occupancy: PRIVATE GARAGE Slopes: Y Sewer: N/A KALCHIK STANISLAV & LYUDMILA 14261 53 AV S, TUKWILA, WA 98168 KALCHIK STANISLAV & LYUDMILA 14261 53RD AVE St. TUKWILA WA 981684423 LYUDMILA KALCHIK 14261 53 AV S, TUKWILA, WA 98168 *•**•***********, * * * * * * * * * * * * * * * * * * * * * * * * * * * * **fir * *** * * *"* * *. * * *• * * * * * * * * * * * * * *'* ** Permit Description: Phone: 206 243 -8004 Phone: 206 243 -8004 Phone: 206 243 -8004 CONSTRUCT NEW GARAGE. Units: 001' Buildings 001 Fire Protection: N/A UBC Edition: 1994 Front: Left: SETBACKS-. .0 Back: .0 Right: Valuation: 15,519.28 Total Permit Fee: 395.96 **•*******************'** * * ** * *' * * * * * * * * * * * * * * * * * * *•* *'k ** *** ** * * ** * ** * *•* ** *• * ** Permit Center Authorized Signature Date I hereby'certify that I "have read and examined this permit and know the same to be true_ and correct. All provisions of law and ordinances governing; this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construe ion o' the perf•r lame of work. I ain ~authorized to sign for and obtain t bui \di) erm Date: t5 _ 3 ct lJ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. DEPARTMENT D ATE IN "DATE AP REQUIREMENTS / COMMENTS • ti Plan Review Meeting (-1-02D.-q0 1 4 L1 q BY: (init.) NIT: P YQ BUILDING - initial review q Wycva (ROUTED) C ONSULTANT: Date Sent - Date Approved - 3RD NOTIFICATION O FIRE BY: (init.) IREPROTECTION: ❑ Sprinklers 0 Detectors O WA FIRE DEPT. LETTER DATED: INSPECTOR: INIT: 0 PLANNING ,A t4 L , ZONING: PAR /LANDUSECONDITIONS? OYes 0 N REFERENCE FILENOS.: INIT: MINIMUMSETBACKS: N- S- E- W- PUBLIC WORKS UTILITY PERMITS REQUIRED? Oyes OW PUBLIC WORKSLETTEER DATED: — INIT: -17) (i, J L . C1 t U-rl ( { J7Y ,nC13, > Xf BUILDING - final review 5/3/94, r 9G, ION n'PEOFCt�I(STR C : Vi\I CERT.OFCr'C CY? Dyes XND UBC EDITION (year): 1 99 (p INIT: .46 4BUILDING OFFICIAL 1V3/�t6, INIT: AMOUNT OWING: cks CONTACTED I L N d rY11 l CA-- DATE NOTIFIED ") BY: (init.) -- - ' *1� 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) PLAN CHECK NUMBER FA (0 CITY OF TUKWILA Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PROJECT NAME ulch� o�ni�l�v LuoiMi(Ck SUITE NO. SITE ADDRESS INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N/A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. REVIEW COMPLETED 02)15/96 SITE ADDRESS SUITE # 1 L 1( ')1 5?- Cu) e, S VALUE OF CONSTRUCTION - $ \5 5\R , IS PROJECT NAME/TENANT 'CX‘A s \o`� pct \c� 1 , ASSESSOR ACCOUNT # 1 1,55 ' ` J - O S - -0 Lk (commercial) U Demolition (building) 0 Other TYPE OF New Building U Addition U Tenant Improvement WORK Rack Storage 0 Reroof 0 Remodel (residential) DESCRIBE WORK TO BE DONE: .\ \CA vw 9- Cie-, BUILDING USE (office, warehouse, etc.) 9 CkA — 0.--B . NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? No 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: 'B5 c Tenant Space: Area of Construction: %5 (,) WI LL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING. No 0 Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: 0 Sprinklers 0 Automatic Fire Alarm System PROPERTY OWNER S.V i\A \ clk.\) lcV \ c PHON `d.06 9 y3 — SOD ADDRESS 141 () CU e, 1(Ax„W1‘5k. vi , ZIP()g4( CONTRACTOR 1 PHONE ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT PHONE ADDRESS ZIP I HEREBY CERTIFYTHAT lI HAVE READ AND:EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE: AND CORRECT; . AND :I 'AM. AUTHORIZED`T.O : FOR THIS; PERMIT BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE DATE C PRINT NAME S' A"0`.v\ \5 \0 tom.\ •14._, PHONE p_i 7 — $GU 4 CITY/ZIP ' N cf S \6g PHONE y� _ go 04 ADDRESS L4 93 s.) CU\}� ,- CONTACT PERSON L \I \) ` i � ^ \ CL. � C. \ An , ( CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 p f ,, - c-�(� 3 (,{ (PLAN CHECK /^ S APPLICATION MUST BE FILLED OUT COMPLETELY NUMB ER BUILDING.. PERMIT APPLICATION DESCRIPTION BUILDING PERMIT FEE PLAN CHECK FEE BUILDING SURCHARGE OTHER: TOTAL AMOUNT Nk" , '3‘15q (0 RCPT # DATE:` APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED La-ci( DATE APPLICATION EXPIRES 'OMMERCIAL • : n Completed utility permit application (one for entire project) RACK STORAGE . I Completed building permit application n Assessor Account Number Two (2) sets of plans, which include: Building floor plan showing: RESIDENTIAL l Legal description } Assessor Account Number { Two sets (2) of working drawings, which include: I Completed utility permit application BMITTAL H SU C EC KLIST IEW COMMERCIAL BUILDINGS /ADDITIONS - I Completed building permit application (ono for each structure) 1 Assessor Account Number Two sots (2) of the following: Specifications. Structural calculations stamped by a Washington State licensed engineer ; - Soils report stamped by a Washington State licensed engineer - 1 Topographical survey Energy calculations stamped by a Washington State licensed engineer or architect Legal description 7 Working drawings, stamped by a Washington State licensed architect, which include:. • Site plan • Architectural drawings, • Structural drawings • Mechanical drawings • Elevations • Civil drawings •.Landscape plan Six (6) sets of civil drawings NOTE: See'utility permit application and checklist for specific utility submittal requirements.. • Entire space where racks will be located • Exit doors • Dimensions of all aisles Tenant space floor plan showing rack storage layout, aisles and exits. NOTE: Include dimensions of racks (height, width and length), aisles and exit ways on plan. Structural calculations stamped by a Washington State licensed engineer (rack storage 8' and over). . NEW SINGLE - FAMILY DWELLINGS /ADDITIONS Gar Completed building permit application. (one for each structure) • Site plan - (On plan, show closest hydrant location. • Foundation plan Include access to building, showing • Floor plan . width and length of access.) • Root plan •Building elevations (all views) • Building cross - section • Structural framing plans ash ingt i� Li Six (6) sets of site plans showing utilities NOTE: Building site plan and utility site plan may be combined. See . utility permit application and checklist for specific submittal requirements. Additional topographical and soils information may be required if unique site conaitions. COMMERCIAL TENANT IMPROVEMENTS Completed building permit application (one for each structure or tenant) Assessor Account Number Two (2) sets of construction plans, which include: n Site plan • Location of tenant space . • Existing and proposed parking • Landscape plan (if applicable, i.e.,' change ,of use E Overall bulleiny plan ..Tenant location • Use of adjacent (common wall) tenant • Overall dimensions of building or square footage I . Floor plan of proposed tenant space • Tenant space plan with use of each room labelled. • Exit doors, egress patterns. • New walls, existing wall, and walls to be demolished. n Construction details • Cross sections showing wall construction and method of attachment for floor and ceiling. Structural calculations stamped by. a Washington State licensed engineer may be required if structural work is to be done (2 sets) NOTE: If any utility work Is to be done; submit separate utility permit' application and plans. REROOF .. n Completed building permit application (one for each structure) I Assessor Account Number Narrative describing existing roof, material being removed, and material being installed. NOTE: A certification letter is required prior to final inspection and sign= off of the permit. ANTENNA/SATELLITE DISHES I1 L Completed building permit application 11 Assessor Account Number Two (2) sets of plans, which include: n Site Plan (showing building and location of antenna/satellite dish) Details antenna/satellite dish and method of attachment'• Structural calculations stamped by a Washington State licensed • engineer may be required RESIDENTIAL REMODELS Completed building permit application (one for each structure) Assessor Account Number Two (2) sets of working drawings, which include: • Site plan • Foundation plan •. Floor plan • Roof plan • Building elevations (all views) Building cross - section • Structural framing. plans:' NOTE: If any utility work is to be done provide utility permit. application: and plans must be submitted. building permit application (one for each structure) REROOFS Assessor Account Number Narrative describing existing roof, material being removed, and material being installed. NOTE: A certification letter is required prior to final inspection and sign off of the permit. t...fry OF TUKWILA • Address: 14261 53 AV S Suite: Tenant: KALCHIK STANISLAV Z1 LYUDMILA Type: B-BLDG Parcel #: 725520-0215 Permit No: 196-01ff Status: ISSUED Applied: 04/22/3996 Issued: 05/01:1996 A.**k*****.A***4 Permit Conditions: 1. NC' changes will be made to the plans unless Approved by the 1'01'; w i la Building Di v is i mi. 2. Electrical permits shap:6e:: the Washington State Division of,,Labor-and IndustrieS andall electrical work will be isPeotiid by agency (248=6630) All permits,,. aPP Olailt4 'Z 11611 he available at the fr stat‘t of any c 406ume7ts are to be maintained and-Avail- able un0 AnSpect.ion' approval is granted....,. 4. nee 0:'tisSdrawings and calculations she'll be on.,Site and aValAabie'to the building 'inspector for..inspection purpOses... Documents 174 r bea the seal and signalure of WashA Eniner age. 5. Anv,:jeipoS4W,,inStilations backAnq'material shall havea Flame' „,. Spi: of 25 ori less;::and‘material shall bear ident fiation,showing thefire-pei-formancerating thereof..7,,,: 6. Alit!tonstruction . .t6:-$e . ;donef fp conforiOnce with approed piens andreOuirementSo'f ti.he:140.form.8.0.1.ding Code (19941, Edltion) as amentied,'Piiim MeAaniCal Code (1994 lEdition),, -.,,..4 anAiNashingeoW-5tafe Energ,\Code.t1j'94'.Edition). 2. Al*wopdito 1, be treateW6od 3 . Nt.itilfy tbe l C't t V 'Of Thl..ie:i'la EN il ding: Div t'S on pr t c i or ('‘o:-. ' .,. plae,incl arry concrete';. pir•6cedir:70 .inadditioncien.,: .., . ,. „. retliOrepents for speoal inspeotlow.:_, 9. THER(SHAL1nBE,A FINAL INSPECTfON'AND'APPROVAL OE-ALL:BUILDL. NCIS'SANIJ STRUCTURES WHEN COMPLETED AND PEAD'i FCtl:! OCCOPANC.% 'AND USE. U.B.C::.'SECTJON 108.4 10. Valid);ty of Permit. The issuance 61a bermit:or approvarof plans:,1s1Jecifications, and computations not be con- •ztrued't6„ a'permit or an approval-of. any v;olation of any o the provisions of the building code or. of any other ordinance of the iurisdiction. No permit presuming to give authoritvto violate or .cancel the provisions'of this code shall be va!iti. -- , h+++A+*+»h»*+*****+*+ ^CIT\ OF TUKNIiA. NA ++++++4* TRANSMIT Number: 9600 - P-a`ment Method: CH[C Permit No 096- Parcel No: 7255 Site Address: 1426 This Pavmect A*a*+ak**+L*4;axsk Account Code 000/322.100 000/345.830 000/3O6.904 +*:rA+x+**k+A` � 2 L. ���4+* 4023 Amount: K Notation: 0105 Type: 20-0215 1 53 AV S A++a*IrVe*++*A**++»++h**:1 JWWSOT' +«+^** 395.96 04/22/96, 10:59 LYUDMILA KAiCHIK InitrSL8 B-OL08 BUILDING PERMIT Total Faes: 395.96 Total ALL Pmts: Balance: hA***&4**+^***ith+WA*A**+**++++M+ Dcncription BUILDING - RES PLAN CHECK - HES STATE BUILDING SURCHARCE 395.96 3J5.96 .0O AP.**Ai.*A*.1% Amount 237.25 154.21 4.50 + GENERA GENERA GENERA TOTAL CHECK CHANGE 4844A000 237.25 154.21 4.50 395.96 395.96 0.00 15:O1 Project: // C Type of inspe '• Address "-/ Date called: Special instr ions: Date wanted: 7 3045 0. Requester: Phone No.: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 I I Approved per applicable codes. COMMENTS: Inspector: INSPECTION RECORD Retain a copy with pernL -- I I PERMIT NO. (206 43 1 -3670 Corrections required prior to approval. 1 1, 1 / V J ,4 a 1 Date: 7 $42.00 fi EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection: Receipt No.: Date: Project: / IC/1:k_ Type of inspections CA7 Address Date called: Special instructions: 2' 0 / , a.m. Date wanted: ?-/a-77 m. Requester: Phone No.: MAN INS ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. C MMENTS: Inspecto INSPECTION RECOR Retain a copy with permit GCv,�S u / sv Date: (206) 431 -3670 Corrections required prior to approval. - 2-14-612 $42.00 REINSPECT '• N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Soelthcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: Type of inspection: 1,--, /) Date called: %, i Date wanted: 9P 41 'A ____eieb.,ed1_____— 0 Of gite 4 n ya f a,t_g.tA. - 1 , - / 5 c,‘ 4..."(..... 2 - M ,,t.. / ■ .• .....-,... 5ai4____d 4 . 19 5 live . / e / i-A 7 5 d'• 0 L 7 ( '' , .,. I Project: kq /r. 4 isk Type of inspection: 1,--, Address: M26/ -3 Date called: %, i Date wanted: 9P 41 Special instructions: - 1 00 Requester: Phone No.: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector: I I INSPECT NO. et,e_ INSPECTION RECOR Retain a copy with permit Orr- c7/ PERMIT NO. / (206) 431-3670 Approved per applicable codes. TI(Corrections required prior to approval. Date: $42.00 REINSPEC ION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • - . Project: L. Ch4 -" Type of ins ec�on: Kf. N1gi IhIC� Address: ' 4 2,61 e) 3 S Date called: ( 3 Special instructions: Date wanted: / ?/ T f a.m. �m. Requester: Phone No.: INSPECTION RECORD""' Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: Inspector: (-) Date: 01 /3J Approved per applicable codes. btG - aa5 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date; Project: k � (1/ [ /�. Type of inspection: f /� j Address: / 26:./...s S Date called: s.j Special instructions: Q 60 Date wanted: 3 „ Requester: Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 [1 Approved per applicable codes. .4 ". INSPECTION RECORD Retain a copy with permit PERMIT NO. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No.: (206) 431 -3670 Corrections req "wired prior to approval. COMMENTS: Inspector: Date: q, ) 3 �� Date: Project: ' A I C k 1 Type oe n n Address: 14 Z(Q 1 53 /1 , Date called: 1 —lel _ 4 Special instructions: Date wanted: 1/30m � Requester: + �YVf t Phone No.: S6D j ■3.Y`..!NPreAtCiiSK.'[Y'Y6t' unzfartsvomtvmate Reczn l t mzer X3o.m, 5131 %k!'meotamustrirm,o vesow. ^ INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable codes. COMMENTS: 114 77 $42.00 REINSPEC ' N FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: INSPECTION RECOR Retain a copy with permit D to cq 05 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: __fit! "."S "`COPY i:.r'^ su'.:;��t pla ;;o Coco ac :c:1 ccpy of By + h �T3f'T to crrom and omission3 not authorim codo or ordinate*. approved Cn u Check r_7 .._.`; aro ar.0 c.::::::::.:.1 of the violation of any Receipt of contractor's iU I °1/4- �IC i Ic Date Parr 5 3 — R lD lit No. fig(0-01 a5 ......��< • . rc s ry. rnr.. xnxrrs+ Pasusc, amn,.:. v, wv�nrxxre. er.. orv». wuwvr«. u-, rnnm.. aw,. r ...K.Mrwuw»xr..w..,vrrw4-anm« awn. xr. n...... mr.. m�vw: v<.,.. w. w.. m.. vn.a c... nay.« w�mn+ euvwr wxrra�+ vw+. orw.+ a� e. n... .. +..�....v.:.......... N SEPARATE PERMIT ... REQUIRED HANICAL ELECTRICAL El PLUMBING rJ L .3 PIPING C: m" OF T UI''WILA 1.,2:!..1 )::.:3 DIVISION Go' H DECK I 60' I 9 I I I I I 5 ,lo • 2.0 30 40 - so bo SGALZ. 4 ?-0' 0" CHA T o SCOP PPROVAL 0 NOTE: REVI:;IOI A D MAY IN( /5 —C 7 t 1 rS SHI,''ALL BE MADE TO F TUKWILA BUILDING DIVIJON. S WILL REQUIRE A NEW PLAN SUBMI L LUDE ADDITIONAL PLAN REVIEW FEES. OF WORK WITHOUT PRI' R CITY OF TUKWILA APPROVED MAY 0 2 1996 AS NU1 E.D BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 2 1a9 PERMIT CENTER SITE LkN 5 3 ay.e, N tv O 18'0" 2G'O" itil 'nM`;Vra:SA,Alnfa2`.rri;ar1TI:W OU s'Ter,4C in'AVW0.1g4+s:'nvnvn++tn'NA: .4 4. 0Ntt rY0ter7f nOR /Yc0.2P 3 ° rlPIt t-XB.t 3O`IoHV o� EiJGIN,zy.'R,E � - musss IV 'BRAWL& 'vz LAC 2326,, tt.3 W c W MOOED 0.---"A-ite- L.ac4Tto N t OF MN. 4 Wtbt 13 Gp 14)4u- pANL OF K..` nti m.wAu -sc ¢p• Owt L R-D 41c SE. lac :64 644a-13)e-1 N�c-0 &/ y C orte: & /J 5 DI2 5� " CV4LL NA-14s G 7" e/G )p � S go " FOUNDATION PL .NN SCALE %g = 0 n CITY OF TUKWILA APPROVED MAY 0 2 1996 AS rUIED BUILDING DIVtSION RECEIVED CITY OF TUKWILA APR 2 21996 PERMIT CENTER �C�;tiiL.YattCS :iy:v�t:z. ",r�r. <:.; art:. v: �.. �s���1: x,'..; c.^ r. �,: vsi���M.: r�' �s. ��' kr ;,:ziu:�w�a;ucn•�.t:��; Y1, ye 1 QT N G- MoNoL(T1-k rtWct -re 12I SE LDc4T6o r2. "/t1I!1J1 BECory FINISH 6n-40E ec tiu R 15 ] 1I S_ILLA 1 01\1 \20c14 STS) n S 1 G" f7 C wrstt;:rrraYV -1... ir:sr:;.er. „.udlinIrMfrk:mrrtcigutw:, nr.n.4vr..nv`reraw.w? \A/ALL EN GINEEtt.© TRUSSES 4.LI CITY OF TUKWILA APPROVED MAY 0 2 1996 AS rUiLD BUILDING DIVISI N i 6 I0" ANC,VIfl 0LTS si'AcEo Co. � % 4 - r c4' n,4T -y °oily M000k-1T1 SLAPD �W /W W M R��N F(�R,C, CITY OF TU EIVED KWILA GPPuEI___ APR 2 21996 IZ. Fe:JO /NO, w /(z) 4. Go KT• a Bar PERMIT CENTER