Loading...
HomeMy WebLinkAboutPermit B96-0108 - BOEING #21-03 - SHOP FENCE AND CONCRETE PADCity of Tukwila L. (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: B96 -0108 Type: B -BLDG Category: ACOM Address: 3417 S 120 PL Location: Parcel #: 102304 -9068 Zoning: M1 M2 CM Type Const: V -N Gas /Elec: Wetlands: Water: 125 Contractor License No.: BOEING *294ML Status: ISSUED Issued: 05/06/1996 Expires: 11/02/1996 Type of Occupancy: WAREHOUSE Slopes: N Sewer: VAL VUE TENANT BOEING #21 -03 3417 S 120 PL, SEATTLE, WA 98124 OWNER SABEY CORPORATION 201 ELLIOTT AVE.. WEST, SUITE 400, SEATTLE WA 98119 CONTRACTOR BOEING COMPANY P.O. BOX 3707, M/S IF -09, SEATTLE, WA 98124 CONTACT TERRY ,.BENNETT Phone: 206 544 -2975 P.O.'BOX 3707, M/S 46 -87, SEATTLE, WA 98124 k *:t k * *•k•k * *"k�kik* **"k** **' kilo* k •k ** ** *•k * *.* *•k•k *" *•k*"k" *•k* k k"k•k* k k *•k*** * ** ** k * * *'* ** ***** Permit Description: CONSTRUCT SHOP FENCE AND CONCRETE PAD. SETBACKS Units: 001 Front: .0 Back: Buildirigs: 001 Left: .0 Right: Fire Protection: SPRINKLERED UBC Edition: 1994 Valuation: 4,200.00 Total Permit Fee: 169.09 * ** * *** *!k* k ** ** * * **** ** *• ****•k ** *** ** * * ** ** **** *** **** * * *-k * * ** * * *. **•* * * * ** ** Permit Center Authorized Signature.. Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the p.erf�iance of work. I am authorized to sign for and obtain this burg per lift Signature: Date: 5_ -6- 6 Print Name: Title: This permit shall become null and void if the work is not commenced within 130 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. DEPARTMENT D ATE IN ' ; DATE ; , .AP„P.ROVED R EGIUI REM ENTS /.`COMMENTS Plan Review Meeting Q31b q -d-11- I 0 NIT: Ka P V BUILDING - initial review ti, d 4 - f4_ fd /C ONSULTANT: `I �C� (ROUTED) Date Sent - Date Approved - ig FIREPROTECTION: FIRE /4, yI / S' - O Sprinklers 0 Detectors O WA 'IREDEPT.LETTERDATED: AJ C.,. INSPECTOR: $' // NIT: 4—W1 O PLANNING /�t '� NO ZONING: PAR /LANDUSECONDITIONS? ayes 0 N lEFERENCEFILENOS.: INIT: MINIMUMSETBACKS: N- S- E- W- O PUBLIC WORKS NA )a JTILITYPERMITSREQUIRED? O Yes Orb PUBLIC WORKSLETTER DATED: INIT: BUILDING - final review ' kBUILDING F-2-ci TYPEOFCONSTRUCTION: — g — I Y CERT.OFOCCUPANCY? Oyes (✓1 No �"` UBC rDITION (year): t GZ l Gf `f INIT: f� ��. OFFICIAL � =Z- G l ( G 7�3/ `' INIT: AMOUNT OWING: CONTACTED •' \- �-C2_ � .� 0 � • IF Q(� DATE NOTIFIED 3 �. BY: (init.) 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) PLAN CHECK NUMBER CITY OF TUKWILA Department of Commv,,,ty Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PROJECT NAME 130-690 Qi -o3 oLin lao Pl SITE ADDRESS SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N/A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. REVIEW COMPLETED 02/15/96 SITE ADDRESS SUITE # 7 4 43o ,� ���� 6,2/e--e. S VALUE OF CONSTRUCTION - $ - j; ao . ASSESSOR ACCOUNT #/o,„2 3D 5/ - 90 lob ;; .3 P ROJECT NAMEfTENANT BOEING DEFENSE /ND SPACE GROUP TYPE OF 0 New Building El Addition M Tenant Improvement (commercial) 0 Demolition (building) WORK: 0 Rack Storage O Reroof Remodel (residential) O Other DESCRIBE WORK TO BE DONE: BUI� G�ffi� "ehouse, :tc.) NATURE OF BUSINESS: AtRPLAuFS requirements may need to be mitt' Please explain: WILL THERE BE A CHAN(iE IN fist? ' 0 Yes If Yes, new building SQUARE FOOTAGE - Building:,35._ 947 Tenant Space: Area of Construction: WILL THERE BE STORAGE OR USE OF LAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? )yf No 0 Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: Jg( Sprinklers Z Automatic Fire Alarm System PROPERTY OWNER BOEING DEFENSE AND SPACE GROUP PHONE ADDRESS P.O. BOX 3707 M/S 46 -87 SEATTLE, WA. PHONE ZIP 98124 -2201 CONTRACTOR SAME ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # BOEING -294ML EXP. DATE / — D/ _91 ARCHITECT PHONE ADDRESS ZIP J bourncenrer t ourevara, I uxwr►a vvH Val VC, 1 431 -3670 7 g 710 29.3 -a 9 DESCRIPTION ' AMOUNT.. RCPT 0 DATE BUILDING PERMIT FEE . PLAN CHECK FEE :'"1 (Q N CHECK JMBER / /11 I!' i1 f H' N f, l (! ; T H F z T 11 I E n OUT T C c r, 7P1 f FL 1- Y BUILDING SURCHARGE OTHER: TOTAL • I (()1.CO , PL ! N CITY OF TUKWILA Department of Community Development - Building Division 630 (20 BUILDIt PERMIT APPLICATION I:HEREBY CERTIFY TH BETRUE 'AND;CARRE SIGNATURE VE BUILDING OWNER OR PRINT NAME AUTHORIZED TERRY BENNETT D EXAMINED .T IS. APPLICA . K DATE SI PHONE 544 -2975 AGENT ADDRESS PO BOX 3707 M/S 46 -87 SEATTLE, WA, CONTACT PERSON TERRY BENNETT CITY/ZIP 98124 -2207 PHONE 544 -2975 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architectengineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES 0- g(fi 10/2207 COMMERCIAL NEW COMMERCIAL BUILDiNGS/ADDITIONS : n Completed building permit application (ono for each structure) Il Two sets (2) of the following: n Specifications [1 Structural calculations stamped by a Washington State !leeriest) engineer l i Soils report stamped by a Washington State licensed engineer n Topographical survey U Energy calculations stamped by a Washington State licensed engineer or architect Li Legal description I1 Working drawings, stamped by a Washington State licensed architect, which include: • Site plan • Architectural drawings • Structural drawings • Mechanical drawings • Elevations • Civil drawings • Landscape plan U Completed utility permit application (one for entire project) 11 Six (6) sets of civil drawings NOTE: See utility permit application and checklist for specific utility submittal requirements. RACK STORAGE n Completed building permit application II I II Assessor Account Number Assessor Account Number Legal description I I I iI Assessor Account Number SUBMITTAL CHECKLIST Two (2) sets of plans, which include: n Building floor plan showing: • Entire space where racks will be located • Exit doors • Dimensions of all aisles Tenant space floor plan showing rack storage layout, aisles an exits. NOTE: Include dimensions of racks (height, width and length), aisles and exit ways on plan. Structural calculations stamped by a Washington State licensed ••• engineer (rack storage. 8' and over). • RESIDENTIAL Two sets (2) of working drawings, which include:: • Site plan (Ch plan, show cOsist hydrant location. • Foundation plan include access td butte, showing • Floor plan ` width and langih of wroess j • fool plan • Building elevations (all views) • Building cross - section .. • Structural framing plans Washington State Energy Code data n Completed utility permit application n Six (6) sets of site plane showing utilities NEW SINGLE- FAMILY DWELLINGS /ADDITIONS : Completed building permit application (one for each structure) NOTE: Bulking s i t e plan and u til ity s i t e plan maybe aomblneii. See Utility permit application and checklist *specific submittal regQhw►ronfa Adchtlonal topographical and soils information may be required if unique :: site conditions. Location of tenant • Existing and proporih! parking Lisindscape plan (if applicable, i.e., change of ire) • Overall building plan Tenant iodation ' • Use of adjacent (Common wall) tenant •.Overall dimensions of building or. square footage : Floor plan. of proposed tenant space :••• Tenant space plan with use of each room labeled. • Exit doors, egrets; patterns. • New welts, existing Wall, and walls to be demolished. U Construction details Cross sections showing will constriction and Method of attachment for floor and ceiling.; Structural calculations;strmped by a Washington Stale licensed engineer may tie required If structural work is to be dens (2 sate) NOTE: If any utility work is to be done, submit separate ut ty permit application and plans. REROOF Li Completed building permit application (one for each structure) .. n Assessor Account Nun** n Narrative describing existing rob!, Material being removed, rid material being Instilled; • NOTE: A certification letter is required prior to final inspection and sign - off of the permit. ANTENNA/SATELLITE DISHES n Completed buildin Assessor Account Number Two (2) sets of plans, which include: Site Plan (showing building and location of antenna/satellite dish) . • RESIDENTIAL REMODELS mpleted building permit application Assessor Account Nu rser: (2) sets, of • Ito. > < >. .Pian oundation oor p oof i ldind eiwatione ik!m . croes= ae� :. . • RER • Wind nett d of attachment • Structural calculations ' stamped by a Washington state licensed ;engineer may he required one for each stricture) icatl uctu (one for each st re) Address: 3417 S 120 PL Suite: lenant: BOEING 421-03 .Type: B-BLDG Parcel #: 102304-9068 •.;c: CITY Of. 1UKWILA Permit No: B96-0103 . Status: ISSUED Applied: 04/23/1996 Issued: 05/06/1996 *k*4 4 44444 *4***A*44'444 **444k444444 4 k 4 40k* 4 4 4 41 44444444.44444 * 4441, Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and the Tukwi)a Building Di!..ision. 2 Electrical permits shafTecb.taj1ned.:through the Washington State Division of Industries 'and :*-11 electrical work will be inspeCted by that agency (24a-6630),. I. All per)its,,jpSpectionrecerds,:and approved plans shall be available at the iob Sitorwii.tr staM of an-t ; con- structionhese:doCuments are,to he maintained and able until final Wspection approVal is granted„ 4. All conWuction,to be conformance with approved olans/and regOrements of the06,1form Building 'Code (195!4' EditOn as amended UnifOrm Mechanical Code t19,j4'Edltio0, and f WaAhington State Ener9 yCode Editio10.. ValAd)ty:of,),Permit. The issuance of a permit or approvaLcif Dlans SOlicifiCationSi,. and computation s shall not :,be straed to be a permit an approval of, any .violation of any of the proviS:iOns, of the builAing-code c of any... o0er ordinaOce, No permit presuMing to give autho'rity':to 6an6e1 the provisions or this H: code shall be Valid. 0, l -,r *• .A 4 Ak*• AA***** A* AkA kA.* Ak*A* A• k'.**#*• k *A * *Ak•A•Ak *A'Ak3:** * * #:* *•l.*a /• *ki ?. Permit No: 1196-•0109 Type: 11 ••BLDG BUILDING PEPMIT Parcel No: 102304-9068 Site Addr sls -s: 3417 9 120 PL. Total Feo.i: 169.09 This PE,vin r.t 169.09 Total ALL Pmt:,: 169.09 Balance: .00 AA AA *;.hA*iA *A *A*A *k•k•,F *A *AA *AA AAAA *A kA **Ak *At *AAA'*:F *A• **A*A ** Account Code DeEoriution Amount 000/322.100 BUILDING - NC'r1RES 99 „ 75 1;00 34`,.800 PLAN CHECK 14QN12E1 64.,84 000 /396.904 STATE BU1 :I..D1:NG SURCHARGE 4.50 GENERA 99.75 GENERA 64.84 0 Q GENERA 4.50 CITY OF r x �� 11. ra , l ra f �� :ash a M I 'r TOTAL 169.09 ** *AAA *Ak*4 * *A** * * * ** vt * * *k * ** i•i *•! A* k *:F ** * *•A *A,*Ak * ** r 4 � t a CASH 180.10 TRANSMIT Number: 960040'36 Amoun..: 16 ?.09 04/2J/9E 13:12 CHANGE 11.01 Pt,vme:nt Method. CASH NctEttiari. BOEING 1r1 1) »3I'` & 123 4862 A000 12. _.. _._.. .._..._..._._..___._._.._...... _._.. _._ ...._._ _..._ _.__ ............. _..._.. __.._.._. _ . _._._.. 2; 14 FINALAPP.FRM City of Tukwila Fire Department Project Name U; Address ..��y /D S /LC) ,PL Retain current inspection schedule Needs shift inspection Approved with correction notice issued Approved without correction notice Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM { Date T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. ?c- c f0 O8 Suite # 6.) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575•4404 • Fax (206) 5754439 Project: 5 7.1 —03 , Type of inspe Address i (26 0 . Date called: Special instructions: , Date wanted _ a. Requester: Phone No.: r. INSPE ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable codes. COMMENTS: I I Inspecto INSPECTION RECORD Retain a copy with permit [ - PERMIT NO. Corrections required prior to approval. Date: 5 4, $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ( 0 i •-**1•••••■•••••••••••4.-•••••••••••••••••••••••• • THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A DEPARTMENT OF LABOR AND INDUSTRIES • .... STATE OF WASHINGTON ISSUED BY DEPARTMENT OF LABOR AND INDUSTRIES F625-052-000 (3-92) VICINITY MAP AREA MAP . / / \, FROM DOWNTOWN SEATTLE f KING BLDG. 21 -03 ADDRESS 3417 S0. 120TH PLACE SEATTLE, WA (EAST MARGINAL WAY CORPORATE PARK) PROJECT SITE COUNTY AIRPORT OFFICE 900 CENTER (FAA) s g �% 9' ��' ° O U � ° � `� \a _ o° gg — a EXIT :� IX 158 158 moll 1oT • d �s Cy ACCE$ � , Q V $ BOEING Q� ' ' f 21 -02 21 -01 21 -03 I — � 21 -05 PROJECT SITE NIT \ �4 157 \T 900 5 1� �/ I, 1 \ / % T i- \ Topr ` -ire, AY 599 EAST MARGINAL WAY TUKWILA FROM KEN T\\ & AUBURN CORPORATE PARK 99 FROM SEATTLE- TACOMA AIRPORT NOISCALE DEVELOPMENTAL CENTER — _ _ _ 1 -- - N NO I SCALE EAST MARGINAL WAY CORPORATE PARK sru REMAON BY AMMO DATE sn% 3C� C2 ?a0oG REVINON NG BY RAM SHOP AREA (J#787293-00) BOEI\G DEVELOPIV 9725 EAST VARGIN TU '<WILA, WASHI\ APPROVED DATE JEFENSE AND SP AWEA SAG FACILITIES DEPARTMENT E \TAL CENTER AL WAY SOUTH GTON 98108 GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO TERRY BENNET AT BLDG. 9 -51 COL N /1, AFTER COMPLETION OF THIS CONSTRUCTION. PROJECT CHECKLIST CHECK BOX ® THESE DRAWINGS CONFORM TO THE 1994 U.B.C., U.F.C., U.P.C., AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ® ENGINEERING CALCULATIONS ( IF APPLICABLE ) ® ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 10 -A. ® BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. ❑ NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: 1. GENERAL PERMIT (SHELL & CORE) 6 SETS OF ENERGY CALCULATIONS 2 SETS OF CIVIL DRAWINGS WITH UTILITIES 2 SETS SOILS REPORTS, STAMPED BY GEOTECHNICAL ENGINEER 2 SETS STRUCTURAL CALCULATIONS 2 SETS PROJECT CONSTRUCTION SPECIFICATIONS 2 SETS TOPOGRAPHICAL SURVEY 2 COPIES OF LEGAL DESCRIPTION 2 SETS OF WORKING DRAWINGS ® 2. TENANT IMPROVEMENTS, 2 COMPLETE SETS ❑ 3. MECHANICAL 2 COMPLETE SETS ❑ 4, FIRE PROTECTION /SPRINKLERS, 2 COMPLETE SETS ® BRIEF PROJECT NARRATIVE PROVIDE APPROXIMATELY SEVENTY (70) LINEAR FEET OF SHOP FENCE (8' -0" HIGH) WITH SLIDING GATE AND MAN DOOR. PROVIDE FOUR (4) PALLET RACKS (14' -0" HIGH). PROVIDE EIGHT 8) SECTIONS OF 36" x 36" SHELVING WITH SIX (6) SHELVES PER SECTION (EVENLY SPACED). PROVIDE SIX (6) 4' -0 x 8' -0" x 1" STEEL PLATES. PROVIDE CONCRETE SLAB AND STRUCTURAL STEEL STRUCTURE FOR HVAC UNIT. 15%---- DI Ot ❑ AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 • SEATTLE, WA. 98124 ° CE GROUP) ACCEPT/OLIN P x AP PROWD BY CHILLER CHECKED DATE CHILLER DRAWING INDEX DRAWING NUMBER 21 -03 -A1 21- 03 -1A01 21- 03 -1A13 21- 03 -A501 SHEET NUMBER Al 1A01 1A13 A501 TITLE TITLE SHEET FIRST FLOOR PLAN FLOOR PLAN SECTIONS AND DETAILS REVISION NUMBER ORIG B A ORIG DATE 04.04.96 04.04.96 04.04.96 04.04.96 CODE SUMMARY LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS AREA /EXIT CALCULATIONS 1ST FLOOR TOTAL: 36,000 SF OFFICE: 21,436 SF /I00 = 215 OCCUPANTS COMPUTER ROOM: 12,318 SF /300 = 41 OCCUPANTS TOTAL: 256 OCCUPANTS 2ND FLOOR OFFICE: STORAGE: TOTAL: BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION EXTERIOR NON- BEARING WALL STRUCTURAL FRAME ROOF SEISMIC ZONE WIND LOAD SNOW LOAD TUKWILA 1994 U.B.C., U.F.C., U.P.C., WASHINGTON STATE ENERGY CODE AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA ZONING GROUP B TYPE V -N (SPRINKLERED) 236,530 SF 256,948 SF TOTAL: 36,000 SF 32,647 SF /100 = 327 OCCUPANTS 1,020 SF /300 = 4 OCCUPANTS 331 OCCUPANTS GRAND TOTAL: 587 OCCUPANTS /50 = 11.74 LF REQUIRED EXIT WIDTH 12,00 LF PROVIDED EXIT WIDTH 30' -5' 2 1,274 BARRIER FREE S PR IN KLER ED UNPROTECTED 1 -HOUR AT OFFICE; V -N AT WAREHOUSE AREA RECENED 1 -HOUR AT OFFICE; V -N AT WAREHOUSE AREA C."' °FTUKWRA 3 APR 2 3 1996 80 MPH EXPOSURE C 25 PSF PERMIT CENTER DATE 04.04.96 k -4 -9 SUPDTLE FILE COY ea:Isere derHtand that the RICH Chao' t1. 110 otrors and " ke as does not son. t 1 T r V Se ,oA ofi,tapprot Date._ - 77 —?3-9 ,(J2—°1° ' TITLE SHEET SA ,3]C O MECI{ASdIC,G v'ELEC (11,00 H 0 GAS PW6N A CITN 0P Ip311 1015 l$11.0 ARCHITECTURAL MASTER BUILDING 21 -03.1 D.C. LAST RESIGN I Srusa DAR SHEET Al 767293 -00 onm 21-03-Al STM RENSION BY A ?PROVED DA IE BrM s� B. APPa °WB DA ®®L®AW FACILITIES DEPARTMENT ❑AUBURN, WA. ❑ EVERETT, WA. ❑ KENT, WA. 0 PORTLAND, OR. ❑RENTON, WA. ■SEATTLE, WA. 98002 98201 98031 97220 98055 98124 ACCEP1A µLN BPEDRU°BN IS AP(ROVED EDDE DUARiE 12 -18 -90 suan FIRST FLOOR PLAN usr Igygpp, BArz 1 A A 05720147 INSTALL PALLET RACK REV. 1 (SIDE BY SIDE) J. BURKS _ E° 1 A01 B C2 PROGRAM SHOP AREA (4767293 -00) GMM 04.04.96 APPav ° BY °En.. °A� _ _ " RE B UILDING 21 -03.1 ARCHITECTURAL MASTER ALL CORP. PARK E ° m � 910738 -02 . PRxiR 00 -4A) , 21- 03 —SA01 8 OP PROJECT AREA I IIIIIIIIIIIII oi o FLOOR PLAN SCALE: 1 "= 30' -0" LEGEND: GENERAL NOTES: 1. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE AREA HAS BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE AREA OF CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THIS WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. THE FOLLOWING MATERIALS IN THE AREAS ADJACENT TO THIS JOB ARE ASSUMED TO BE POSITIVE FOR ASBESTOS: A. FLOOR TILE B. SHEET VINYL C. VIBRATION JOINT CPONNECTOR CONSTRUCTION NOTES: RECEIVED CRY OF TUKWRA APR 2 3 1996 FEWAT CENTER J \ ` `,`1 (2 ) 1 LEGEND: — I t e... ■ - - -- — o 0 GENERAL NOTES: 1. ASBESTOS NOTIFICATION: A GOOD FAIN SURVEY OF THE AREA HAS BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED NAT WOULD BE INVOLVED IN THE AREA OF CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THIS WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. THE FOLLOWING MATERIALS IN NE AREAS ADJACENT TO THIS JOB ARE ASSUMED TO BE POSITIVE FOR ASBESTOS: A. FLOOR TILE Et SHEET O C. VIBRATION J CONNECTOR CONSTRUCTION NOTES: .. I ■ 0 •• �� 7 UP , 1 HI II it INSTALL FOUR (4) SECTIONS OF PALLET RACK (14' -0 "L x 3' -4 W x 14' -0 "H). INSTALL THREE (3) SHELVES PER PALLET RACK (4' 4, 8' -4" AND 12' -8" ABOVE FINISHED FLOOR). INSTALL TWO (2) ANCHOR BOLTS PER BASEPLATE I N S OI TALLTWELVE (12) L MINIMUM SIGNS EMBEDMENT). E TO READ "MAXIMUM SHELF LOAD 5,000 LBS UNIFORMLY DISTRIBUTED ". 2 - INSTALL EIGHT SECTIONS OF METAL SHELVING I II — — Q w � _ ' (8) (36 "W x 36"L). INSTALL SIX (6) SHELVES PER SECTION. INSTALL WITH 6' MINIMUM BACK `_ TO BACK DIMENSION - rr� iii INSTALL FIVE (5) SECTIONS OF WELDING SCREEN WITH CONNECTION KITS. fil r>" INSTALL SIXTEEN (16) SECTIONS OF METAL SHOP FENCING (8' -0" HIGH). AI U.!, 1!J -` t AI 3 A of INSTALL ONE (1) 8' -0 "W SLIDING GATE WITH 12' -0" HIGH TRACK WITH TWO (2) PULL HANDLES, HASP AND PADLOCK. 1613 A 01 INSTALL ONE (1) 4' -0 "W SWINGING DOOR WITH LOCKSET BOX AND UNICAN LOCKSET. PAINT ALL SHOP FENCING BDCT. Q A At 5. PROVIDE SIX (6) STEEL PLATES (4' -0" x 6' -0' z 1" x A36 STEEL). EXISTING PALLET RACK, NO WORK. i> INSTALL 5' x 3' x 6" THICK CONCRETE PAD AND 48" HIGH STEEL FRAME TO SUPPORT A NEW FAN UNIT. U FIRE EXTINGUISHER AND SIGN. � NKW\U* D 1613 6501 41.16, 42 -U i - I r1A A5 1 2'-6" -61- 1613 A501 1 / O ` \ / b • - I' =" 8' -O" I A- - { ,, CpeQgpV 2 \956 t'\ � ��.. GATE W (; 01$ o o ,, o 1 D . SLIDING Ms Ms us us UP MS MS MS MS a ■■ r 1A13 A501 D D = I ® MUM == == PR sexaQ PR sBxao . �O I O 4D ® 1111111111111 1611, 1 1812 1111111111111 DP � IBIS 1814 r MI -- — ,,, 1616 I 1815 i W3 III PLAN KEY ® I e) (IC) OZ SCALE: 1/8 "= 1' -0" PLAN CD REC EIVED W CRV OF TUMM APR 2 3 1996 PERMIT CENTER DOM A C2 PROGRAM SHOP AREA J1767293 -00 at WPM drt ®_03.08.9.- li BY MFPJRO drt aac E aM SPffG1°"M"° E EP. DU ARTE V11 -90 sunnnE FLOOR PLAN 115.0I UST . SIM drt ___ BoEZAW CHEM >«m 1A1 3 d DEFT. max. - BUILDING 21-03.1 ARCHITECTURAL MASTER N - U/1 - 4.5 CORP. PARK _ FACILITIES DEPARTMENT --- DISC. --M e— we 21- 03 -IA13 - _ __- ___ 4 -� ? D nP. ' / C6x13, TYP. GENERAL NOTES FOR SECTIONS: A, B. D AND E C6x13, TYP. A STEEL SHAPES AND PLATES ARE ASTM A36. 1 1/2" SQUARE GA. COLD TYPICAL ROLLED STEEL TUBE A501 1 / 8 1 L2x2x1/4 COLUMN, TIP. L2x2x7 /4 BRACE 1. ALL 2. ALL WELDING TO BE DONE BY WABO CERTIFIED WELDERS USING E70XX ELECTRODES. 3. MECHANICAL UNIT MAX. WT.= 500 LBS. 4, CONCRETE: Pc= 3000 PSI, W/C =0.55. 5. REINFORCING STEEL: Fy= 60 K51. TYP. 6 YELLOW. J 1 BRACE / 9/32' THRU H E BEVEL CORNERS , r = I __ HTAL L TD S - 1 "x TYP. J 6 I 3/16 I 8" 28" ; 5 / '/ FROM GROUND ASPHALT CLEAR FROM GROUND EXISTING ASPHALT 1 i/4SOUARE � STEEL TUBE SLEEVE PLUG WELD (2) SIDES �� STEEL 1 BASE P ° 9/16" HOLES TYPICAL (4) LOCATIONS TO CONCRETE FLOORS A�Oi TYPICAL 4 PLACES, EACH SIDE WELD A TO AT ASIDE Ef AL FRAME 6" O.. 1 "x1 "x1 /8" "C' � 1 EXISTING PAVEMENT � PAVEMENT 96" ROUGHEN AND CLEAN EXIST. ROUGHEN AND CLEAN EXIST. ASPHALT SURFACE PRIOR TO ASPHALT SURFACE PRIOR TO - PLACING NEW CONCRETE PAD SIDE ELEV. MECH. UNIT SUPPORT A PLACING NEW CONCRETE PAD END ELEV MECH UNIT SUPPORT "r WITH 1/2" BOLTS & EXPANSIONS SHIELDS. � � NOTE: 100% WELD TUBE & SLEEVE 12 AT 4' -0" 1 AT 2' -8" SCALE: 1 " =1' -0 1A131 TO BASE PLATE. SCALE: 1 " =1' -0 1A A501 : iv CONTINUOUS WHEEL TRACK FOR GATE. WELD TO "L" // C 1 8 I / l___ WI 3 "xi 1/2 "xi /4" "L' SUPPORT FOR TRACK. WELD TO TUBES 1 1/2 "x1 1/2" STEEL "L" FRAME WITH TWO (2) INTERMEDIATE VERTICALS POST X 1/2" COLUMN TOP PLATE 1 AT 2' -6" 2 AT 2' - ) 1 AT 4' -0' (SWINGING DOOR ELEVATION � . WI 1111 L2x2x1/4 COLUMN BELOW 3/16 I DETAIL DETAIL NONE 1A13 A501 1 "xi "x1/8" "L" H' I ® L2x2x1/4 SCALE: 3/16 I SCALE: NONE 1A13 A501 WELD ANGLE TO TOP OF GATE 1 1/2 "x1 1/2' STEEL TUBE BEYOND 76 GA SHEET METAL , • I • ® 1/2 "9x4" MIN. EMBED. "HILTI" SHOP FENCE GATE MADE OF I I/ b STD SHOP FENCE PANELS WITH 1/2 "01 1/2" STEEL "C' AT ALL EDGES ` MK 1/2 "9 A307 BOLT, K BOLT, TYP. TOP COL. 2 i1P. -RASE PL1/2x4x0' -4" - _-IV 9 3 "- TOP PL. COL. BASE PL. a "` /Z'\,- _' 16 GA. SHEET METAL WELDED TO INSIDE FRAME ALL 6" O.C. 1 "x 1'x1/8' "C' SHOP FENCE GATE MADE OF STANDARD SHOP FENCE PANELS '' I1 r I� 'i _,1:, SCALE: 3"= 1' -0' A501 SCALE: 3'= 1' -0' A501 '�. 16 GA. SHEET METAL WELDED TO INSIDE OF FRAME AT 6" O.C. 1 xt x1/8 L 1 i/2" UBE BEYOND 16 GA. WELDED TO INSIDE O.C. ,/.� A501 4„ 2 PLACES, ;' T 1 ,„ 2 1/4" 1/8 V 1" 3 SIDES 1100%\ DETAIL n DETAIL n INTERMEDIATE 1 "x1 "x1: DGE ma 16 GA EXPANDED METAL 1 „ xi„ 111 �\ 1111111111111) 1L Ilk 1 11 ��1 16 GA SHE 1 \ L 1 „x1 „x1 /8” 1 SCALE: NONE A501 SCALE: NONE A501 2 "x2 STEEL ANGLE GUTTER FOR GATE AT SOLID FENCE PANELS. WELD TO DE OF FRAME AT 6' O.C. j _ N%I- �� t "xi „x1/8„ L' 12 %12 %1/4" STEEL BASE PLATE _MI BOLTS 3" U M ENT — �� , ” 111111 �';, " " " "j" I U �� !'111111111� 111 ^ ^ 11, 1,1�� ^ ' ^ ` 11� FOR LOCKSET WITH 1 HICK �1 `, �� - �-- 1 3/4" ' -- ” ,,,.,...._. / 8 D � ' p1t \I ( ) I NOTCH EACH SIDE - 4 0 O - 1 „ „ x1/8 „ „L” 1996 D METAL 1 BOX ( ET STEEL) BOX IS OPEN AT v 111 'x1/8” "C' STIFFENER 1 \1� f �/4 /B" THICK 111111111111� ) R .� IS OPEN AT ENDS) „ , I SHOP FENCE PANEL LOCKSET EBOX PANEL AT WELDAT011NSIDE FRAME AT G' O.C. 1 "xi "x1/8" "T FRAMETAT1651Dp C \N \ON 1"xrxi O11 76 GA EXPANDED METAL TINSIDE FRAME AT 6" O.C. BASE PLATES AND TUBES ii - -- -- L SHE 1 0, •: \111' CES 1/g I \111\ �� CUT ` NEL 11i11A�1111111 LOCKSET • `1i1 flECENED CT' OF TIIxWRA APR 2 3 1996 PEPMR CENTEfl DETAIL DETAIL n BASE 1/8 I DETAIL (FROM INSIDE) n SECTION n SECTION SCALE: NONE t A13 A501 SCALE 6"= 1' -0 1A13 A501 SCALE 6"= 1' -0" A501 SCALE NONE A501 SCALE NONE Av07 APPROVED DA. sw REVISION BY APPROVED DATE 111 AUBURN, WA. 98002 ❑EVERETT, WA. 98201 81WArAci7 ❑ KENT, WA. 98031 FACILITIES DEPARTMENT III PORTLAND, OR. 97220 ❑RENTON, WA. 98055 • SEATTLE, WA. 98124 ACCEPTAB LIP( D ° ° ' A " D ° DR .B TaPRDaD &. M I LL ER sue" SECTIONS AND DETAILS , X BUILDING • 21 -03.1 ARCHITECTURAL MASTER - DC . � IB+>+BO� ogre yTM REVISION BY °'B°°° ogre seEr A501 APPR...., ^ .T• ogre MILLER .G. MILLER CH D .1C'"' 767243 -00 oa RD 21- 03 —A501 . rm 4h-'+e APPROVED