Loading...
HomeMy WebLinkAboutPermit B96-0111 - DETROIT AUTOMATED SYSTEMS - OFFICES, CONFERENCE ROOM AND STOREFRONTCity of Tukwila l_. L,! (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: B96 -0111 Type: B -BLDG Category: ACOM Address: 10841 EAST MARGINAL WY S Location: Parcel #: 032304 -9172 Zoning: M2 -L Type Const: V -N Gas /Elec: Wetlands: Water: SEATTLE Contractor License No.: AUTOMEC055MJ Status: ISSUED Issued: 05/15/1996 Expires: 11/11/1996 Type of Occupancy: OFFICE Slopes: N Sewer: VAL VUE TENANT DETROIT AUTOMATED SYSTEMS 10841 EAST MARGINAL WY S, SEATTLE WA OWNER DIAMOND PARKING INC DEPT *0909, 3161.ELLIOTT AV, SEATTLE ,WA,98121 CONTACT RON WRIGHT Phone: 206 728 -4248 1932 FIRST AV #616, SEATTLE WA 98101 CONTRACTOR AUTOMATED EQUIPMENT COMPANY INC Phone: 624 -4660 904. 1 AV S, SEATTLE WA 98134 ********************************************* * * * * *** * * * * * * * * * * * * * * * * * * * * * ** Permit Description: CONSTRUCT OFFICES, CONFERENCE ROOM AND REPLACE EXISTING STOREFRONT. SETBACKS Units: 001 Front: .0 Back: Buildings: 001 Left: ::0. Right: Fire Protection: SPRINKLERED UBC Edition: 1994 Valuation: 50,0.00.00 Total Permit Fee: .952.84 k k k k k* k * * * ** it* k* k* k * * * * * ** k*** * ** * * ** * * * * * * * * * ** * ***•k * ** *tit * *** * * * * * * * * *•k ** Per Center Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Signature:�l��v Date =. 1 910 Print Name:, r � #-: Title: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. >: DEPARTMEN ; D A T 4. .. EtIN. t . :DATE i ; ' ' ' APPROVED REQUIREMENTS /,.:COM Cg Plan Review Meeting y ay-gb • a cp- q K, 2nd NOTIFICATION INIT:P BUILDING - initial review 3RD NOTIFICATION r. ` ONSULTANT: Date Sent - Date Approved - 5 2 � 6 (ROUTED) FIRE 2 -c , L IREPROTECTION: Sprinklers O Detectors OwA — IRE DEPT.LETTER DATE : 1, /n INSPECTOR: S7,2 NIT. IL J ' / -/ Q PLANNING ! ,lc) //'/' 6- �/� /r ` ZONING: Mi [, /..{_ pAR /LANDUSECONDITIONS? 0Yes EZNo 'REFERENCE FILE NOS.: NIT: /`l (: MINIMUMSETBACKS: N- s- E- W- PUBLIC WORKS �I�L'�( `` r� I, I t(p V !1/ UTILITYPERMITSREQUIRED? OYes tab I'UBLICWORKSLETTERDATED: !NIT: U4-i )i.-1 (mit A BUILDING - final review 5_1.3_9 TYPEOFC NSTRUCTION: — f - - 1 ( '4-j CERT.OF000UPANCY? Oyes ,Q Nb L:_E. EDITIO.t' (year): 1,541 NIT-cr..-L_ 0,BUILDING OFFICIAL S C3 - i t o IL) INIT: AM citiNrk, O NG:(i � 0 �J ST II 1, e�"I CONTACTED K on DATE NOTIFIED 5-1 j _ �J BY: (init.) ...415 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) CITY OF TUKWILA Department of Comm ry Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 P% . co37 Building Permit Application Tracking PLAN CHECK NUMBER "59b I I PROJECT NAME D-e*rc maf / 5 SITE ADDRESS SUITE NO. t - _p q m000al V / s INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N/A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. REVIEW - EQMPLETED Oa/15/96 owu Ouumcenrer rsourevara, I myna VVH VO I 00 (206) 431 -3670 p q _ 003 DESCRIPTION AMOUNT RCPT # DATE > BUILDING PERMIT FEE • 5 �r'1 PLAN CHECK /_ � NUMBER L 'P ( APPI ICA TION IllLJS T HE FILLED OUT COIIIPLETEI Y PLAN CHECK FEE. •` . 31 .:59 BUILDING SURCHARGE ' •'I: •SO• OTHER: ` TOTAL-' :... `-q:6a : gy SITE ADDRESS j 0 ,( "1 SUITE # - 7 EAsr MAF NAL. kx/ / 5tUTH VALUE OF CONSTRUCTION - $ 50000 PROJECT NAME/TENANT re rgoi r AUTOMATED 6Y57 6M 9 ASSESSOR ACCOUNT # an: -1112 -0 TYPE OF U New Building U Addition LeTenant Improvement (commercial) U Demolition (building) WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) U Other: DESCRIBE WORK TO BE DONE: 7 o r /o1P ovEmeA/7 , i egrEiveng. 5TageFRasir - BUILDING USE (office, warehouse, etc.) ? ' 1 4L P A l b O C C A 7 7 b /I uHaP / eprAio0$ if 7A /L., NATURE OF BUSINESS: METAL FAaRICArows WILL THERE BE A CHANGE IN USE? MNo 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: 1 8$0 Tenant Space: III 880 Area of Construction: 2754 WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 0 No MYes IF YES, EXPLAIN: / FIRE PROTECTION FEATURES: CVSprinklers 0 Automatic Fire Alarm System PROPERTY OWNER Ly /AMM/ 0 pA go 046. PHONE 28 ADDRESS % e7f I Ava. sai nt cmA . E lior ZiPala1 CONTRACTOR E,E, pargizAwsigr, I ~ u J tA -M t > eu � �.1( � PHONE ( �y _ ADDRESS `o 1 4, A,\ fAN j rk ZIF \3 LI WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT / V1iig1Cr1. 7" ii Aro.�l. lk7es /Altai TvGrs es, PHONE 12,8 0 4246 ADDRESS Z Rigsr Av6,Ajug SU17 teg4 govrtg WA ZlPcgiB in 1 CITY OF TUKWILA Department of Community Development - Building Division I OR BUILDING OWNER • PRINT NAME c.58/1lv,it L ii 'Svi+/ BUILDINfl PERMIT APPLICATION I .HEREBY CERTIFY I HAVE :READ AND EXAMINED THIS APPLICATION AN KNOW; THE SAME: • BE TRUE AND: >CO AND I A THORI > O A'. FOR : T HIS !:PERMIT SIGNATURE ---------------- - AUTHORIZED AGENT ADDRESS cr - � e CONTACT PERSON goo wJ /r 1132. I,7' Avg #;.0(O sMTrte q8)O/ DATE ? PHONE G 6j' - 6/660 CITY/ZI P S ca� f/ C G 7,,c,( 9 PHONE '728 -424 i APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of CITY velopment Building Division at 431 -3670. DATE APPLICATION ACCEPTED "7 _d 96 APR 2 Li 199 PERMIT LbNJ J- DATE APPLICATION EXPIRES 10/22/01 COMMERCIAL NEW COMMERCIAL BUILD$NGBIADDITIONS Completed building permit application .. . .. . Assessor ACcOunt Nurnher•:......••••..••• • •••••.•••• ••••:••••••• • • :::•••":••••••••••••::::. ••••• •••••••••••.::•:•••.::: :.••••••:•:. Two sets (2) of thefollOwing: :•.' ••• ••-• --•-• • Li • ..• ... „ .• :...SpeCifiCations • • ::•:•• Structural calculations stamped by Washingtort•State' licensed • • •••• • • •-•. • • • • • •••"••••• ...• 1:1Energy.'Calculations'starnped by a WashingtonStatelticensed;'p,••••••.::: engineer :•••••••;••••••••:•••' •••••••••'.:•••••••„:.:-•:•-• ".•-••••':',"'•••••:••••:••.•••••,-:::•:-.•••••••-.:••••••:::•••:•:•••,•••••::::::••••••••.•• .. •••••••: .••• • • ••'•• •• •• { Legal description • • : • E Working drawings, stamped by a Washington State licensed architect, which include: . • . . • . ••••••••• ::••••••'••••• ',Architectural drawings•., ••• •••• •.• -••• :•••• •:•• ••.- ....• •• •••:•••••••••••:••••••••:•.•••••••••••• • Structural drawings-,...••••• • .• .. . .. •• • .. .... • Mechanical drawings ••••• •••• •••:•:'‘''':•• • Elevations'. .•:•..•••••••••••••:•••.•••••••••••••::::••,:•••••:::. :••••.• . , • .. • :•••••:••••••••••••:•••••••••••:•••••••••:••••••.‘•"•••:<• Civil drawings ••,--,••••••••••• •••••• • ••••••• •-•••••• • •-.••• • • ••.•,' 1 Completed utility permit application (onefor:entire' project) ,Slx (6) sets of civil drawings NOTE $eo utility permit application and checklist forapec//icutilry 'submittal requirements. . . : . . .. .. . . .. . , , • • :: • RACK STORAGE ; Completed building permit application • , ••• . • •••.• Assessor Account Number Two (2) sets of plans, which include: •.: . . • •• • • • • . . • . Building floor plan shOwing: • • Entire space where racks will be locat Exit doors . . • Dimensions of all aisles . []Tenant space floor plan showing rack storage layout, aisles and exits, • • • : NOTE Include dimensions of racks (height, width and length), aisles and exit ways on plan, . , Structural calculations stamped by a Washington State' licensed .• . engineer (rack storage 8' and over), • .. ' • RESIDENTIAL • NEW SINGLE FAMILY DWLUNGS/ADDIT1ONS • • .•..,•. •:••...-: • ••• .. . •••„•:.•• • • • Soils report storpeo !3y:e1Plashintitciii•State:liCenied engineer .To SUBMITTAL CHECKLIST FI applicationlone fereach:iStructure) : • ..•:••••::•...• • •••,,. •• Legal •-•::•.•••••: Assessor Account Number • LI ••• • • • • ••••• ••••• ••••. •• •.• . • ..•• . Two sets (2) of working drewings, which include:. ••.„ •• •••• H • Site plan (on plAn; show closesi hydrant • • Foundation plan 'Include access to building, showing • Floor . plan': ••••• •••••„":;••• and length of acc ..• " .-• ..... ....... Roof plan:, ; ::::::••••••• • ••,:•••• •••.:,•••. Building elevations' (all ••••• •• Building Croaa-aection.••••••••••-•....::•••'•:,:,...:.•:::::::::::••;..''.::::••'•••••••:: • . . . ........... . • . . . ............ ••••:•••••• .••••••••.• •.'• Structural framing plans • Washington,State.Energy . ...,..... ri Completed utility permit application .••••••• . . • .• 1 - 1 Six (6) sets of site plans showing utilities • • • • . : • • • . NOTE: Building site plan and utility site plan may be combined. See utility permit application and checklist for specific submittal requirements Adational topographical and soils information may be required if unique . site conditions. • . . . COMMERCIAL ;Com p leted IxotOrig jo.erniit'applfcatfens(one.., for each itruoture or tenant) :Astieisot Two;(2) . (;s'ofcOostrOotfon plans, which include . , Site plan :•.:•:,;•:• of tenant .,..,:.,.. • Existing and proposed parfdng Overali building plan • Landscape plan (if applicable, le change of use) . . „:„ .. • Tenant location • Use of •• adjacent (CernMonwell)tenae .•••••■••.0Verell sciu„ Floor plan of proposed tenant• : • .• ••Tenent space use of each roo ,••••••••'::•' Exit.doors, egress patterns '• •••::.• New walls, existing wall, and Walls to be demolished [I] .Construction details-. • „•• ••••,• • .- , • Cr sections showing wall construction and method of acalculations • • - ••• ..• tbachment for floor and • Stru ctat :starnped by, a'Washington State licensed . engineer may be required if structural work is to be done (2 ••• if any utility work Is to be done, submit separateudilty permit • . application and plans. . . RE ROOF I Completed building permit application (one for each structure) r -1 Assessor Account Number Fl describing existing roof, material being removed, and " material being installed. NOTE: A certification letter is required prior to final inspection and sign • : :.•••• .• ••••.• •".- • • . . ANTENNNSATELLITE DISHES F7 Completed building permit application n Assessor Account Number Two (2) sets of plans, which include: E Site Plan (showing building and location of antenna/satellite dish) Details antenna/satellite dish and method of attachment Structural calculations stamped by a Washington State licensed engineer may be required • • • • : • • . RESIDENTIAL REMODELS Completed building permit application (one for each structure) Assessor Account Number . . • . Two (2) sets of working drawings which Inc! ude. S te plan plans Foundation o ian • Floor plan • . Building • fplan elevations(all views) NOTE If any framing utility work is to be done provide utility permit application and plans must be submitted ri Assessor Account Number . • • . R :•••••.: [1 Completed permit application (one for each structure) • • • •• •• • •• • • • • :•.• • •••• ••••. • •• • •••••• ••• •-• . . •••.: . . • . • . -•••• . . ••:: • .:: • :•••• • • •.•• :.• • •• •:.: .• .• : • • ••• •.:.:••••:•••• • ••• • • •••:••• :••• •..:.„ „. Narrative describing existing roof material being removed, and . • • material being •,... • : •:•.. .••.. •,:::..:• •.• •:•••: NOTE A certification Jotter required prior to final Inspection and sign7 off of the permit ' loS41 Address: 1-e&mt EAST MARGINAL WY Suite: Tenant: DETROIT AUTOMATED SYSTEMS Type: B-BL' Parcel #: 032304-9172 CI T';! OF TUKWILA Perm : B96-0111 StatOS ISSUED Applied 04:14/1996 Issued: 05/15/1996 .4 4,4 4*4 441,44,04.44 44*****4'4 1,444-6-44 44,444.44*..**4 ,,,, kkk444 , k444.41.4k*kk4 l. Permit Conditions: 1. PRIOR TO FINAL SIGNOFF APPLICANT SHALL RETURN METRO SEWER ' USE CEPTIFICAlION 10 PUBLIC WORKS fOR PROCESSING AND MAIL METRO BUSINESS 1*ECLARATION:1'0 METRO.- 2. No changes will be made to the plans unless approved by the Architect or Engineer and.:theTukioilla Building Division. 3. Plumbing permits Shall be •obtained throughthe Seattle-King County DepartMentof Public:Health. Plumbing will be inspectett:by'that agency, including all gas piping (296-472 4. Electrl:Cal permits shall be obtained through the Washington StatejiAvislon of Labor and IndOstries and a electrical work:wAll,be inspected by :that agency (243-6630). 5. All work ha he under sepaate permit issued by the;:City:of Tukwila. , • • 6. AlL inspection records, and approved plas shall be availableat the jobsite prior to the start of any et truction These dbOuments'are to be maintained and avail- able until fina) AnspeOtion appr ls. granted. 7, Any ceiling gridand light fIxturetnstailation is redOired to meet Aateraltwacing requirements for Seismic Zone . O. Partitibn-walls attached to ceiling grid'must be laterally braced it Ovey eight-(8):feet in length'. 9. exbosed insulations backing Shall have a Flame: Spread Rating of 25 or iess, and mate'rial• shall bear ide ficationshowing the fire performance rating thereof. 10. All 'construction to be done in conformance . with approved p1anS,and requirements of the Uniform Building Code (1994 EditionT.as amended.Uniform Mechanical Cede (1994 Editio and Washington:State Energy Code (1994 Edition). 11. Validity:of Permit. The issuance u t a permit or approval of plans, specifications, and computations shall nOt Pe con- strued to ba . a permit for „or an approval of, any violation of any of theprovisions of the butlding cede or of any other ordinance :of :the jurisdiction, No permit presuming to give authority to'violte or cancel che provisions of this code shall be valid. ' 11. VENTILATION IS REOUIRED FOR NEW ROOMS AND SPACES OF NEW 01 EXISTING BUILDINGS IN CONFORMANCE WITH THE UNIFORM BUILDING '.0[;E' AND THE WASHINGTON STATE VENTILAlION AND 1 NDOOR A.11: OUALITY CODE, CHAPTER 51 -13 WAC. 44444,4 3ti :S5,�.Aii'.4�a4`i>'tY,�?Yxt*� c: `,�r�twruuKeyunws5�www`.oa JJS /jjs Attachments a/s C, City of Tukwila Department of Public Works NOTIFICATION OF UTILITY PERMIT ACTION TO: PERMIT CENTER FROM: PUBLIC WORKS ENGINEERING DATE: JULY 26, 1996 SUBJECT: DETROIT AUTOMATED SYSTEMS 10847 East Marginal Way S Project No. P96 -0037 Activity No. PW96 -0200 Contact Person: Ron Wright Phone No. (206) 728 -4248 cf: PW Utilities Inspector (w /copy of application /plans) Development File (w /copy of application /plans) b 1 John W. Rants, Mayor Ross A. Eamst, P. E., Director THE FOLLOWING PUBLIC WORKS PERMIT HAS BEEN APPROVED FOR ISSUANCE IN ACCORDANCE WITH THE PLANS APPROVED ON July 26, 1996: Permit Fee Street Use $ 25.00 Two copies of the confirmed Utility Permit Application Form and approved plans are attached for inclusion in the permit files. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Prone: (206) 433-0179 • Fax (206) 4313665 I ;HEREBY:CERTIF .T A H VE AD TNlS APPLICATION:AND;:KNOW :THE SAME TO BE:;TRUE :AND :CORRECT Applicant/Authorize. iff Agent Signature: !ii ` Contact Person ( name): R W� )GNTT Print Name: / W' ) / /S7' A& . St)ITt &I Date: 4)z4 V P • RECEi V EUddress: : ; 128 - 4243TY OF r , inf#771Z i V✓A• 1810 1 Phone: 1Z? • 424f) Date Application Accepted: 4-1" a q , q 0 APR 2 rt d9a6Application Expires: /D • ,&, , 7 PERMIT CENTER INF RMIIATION Name of Project: P7 iT AW7?J tATEO Symms Property Owner: Mit>War, PARKjAkr, , J1 . Street Address: a n , `rD# is - r AVE $ . 5fAT7LE , WA Engineer: Street Address: Contractor: 7b DL7eIQ wer) Street Address: King Cty Assessor Acct #: 032 4172.0 Contractor's License #: ERVIC IIIsLINC TE R'' ME PO T << FUND/BILL 0 0 ❑ 0 0 ❑ Water ESCRIPTION OFPRO1. ❑ Multiple - Family Dwelling No. of Units: g Commercial/Industrial `INI .CELI4ANE King County Assessor; • City of Tw,,✓ila Central Permit System – Engineering Division 6300 Southcenter Blvd., Suite #100, Tukwila, WA 98188 Site Address: 16841 54 'T MAIR(r1NAL. WAY &A/T./ Channelization/Striping /Signing Curb Cut/Access/Sidewalk Fire Loop /Hydr. (main to vault) – No.: Sizes: Flood Zone Control Hauling Land Altering cubic yards Landscape Irrigation Moving an Oversized Load Est. start/end times: Date: ❑ Sanitary Side Sewer – No.: Name: Street Address: Name: Street Address: ❑ Sewer ❑ New Building Square Fgp tage: UTILITY PERMIT APPLICATION ❑ Hotel ❑ Motel ❑ Office ❑ Retail ❑ Metro ❑ Standby ❑ Single - Family Residential ❑ Duplex ❑ Apartments ❑ Other: ❑ Triplex ❑ Condominiums ❑ Warehouse ❑ Church Igt Manufacturing ❑ Hospital ❑ Other: Iu$t of existing structures: $ /601 ?,DO Appf,.,, on # Phone: (206) 433 -0179 Phone No.: 2.8) -9465' City /State/Zip: 18134 Phone No.: City /State/Zip: Phone No.: City /State/Zip: Exp. Date: 1 - 00 3 r1 ❑ Sewer Main Extension ❑ Private ❑ Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑Private ❑ Public ❑ Water Meter / Exempt: – No.: S • Deduct ❑ Water Only ❑ ❑ Water Meter / Permanent – No.: — Sizes• ❑ Water Meter / Temporary: – No.: Sizes• Estimated quantity' Schedule: ❑ Other: Phone No.: City /State/Zip: Phone No.: City /State/Zip: ❑ School /College /University Remodel/ Square footage of original building space: H/, 880 Addition Square footage of additional building space: 0 Valuation of work to be done: $ Pro ect melT nA: 7s, , ysre � 5 Val Qi oa S, iti d` T M i AL WAY SOUTH City State/Zip: T8 sZ I_ yin i , ?2' O a ��•� Property Owner P / PARAING -, /NG, Ph Ag -b100 Street Address: City State/Zip: 3/e#/ /or AvJ AVA, 11Z 16121 — Fax #: COLA Person x60 r i PhOne7 Zf , f , Fax t .. 4•27 Ci St 341dre +s' votive. / so ye a!!0 tsbostGC St :r ipo Contractor 7e AO POWS/ 4104 Phone: Street Address: City State/Zip: Fax 1: A hits t: �� ionic ! miso/i#,7s, ttGIGT es Pho St 2drxesrAvirma c Sl � /� l// l s rl�iL toa �i� Fa 28. 4272. Engineer: Phone: Street Address: City State/Zip: Fax 1: .', .MISCELLANEOUS` PERMIT REVIEW: AND APPROVAI REQUESTED ( BE FILLED OUTBWAPPL!ICANT) Descri fon of work to be dons: Me/Vera 4/415 WSTH/A) STEor PIC'h'T - DF -WAy Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ❑ no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantifies & Material Safety Data Sheets ❑ Above Ground Tanks ❑ Antennas/Satellite Dishes ❑ Bulkhead/Docks ❑ Commercial Reroof ❑ Demolition ❑ Fence ❑ Mechanical ❑ Manufactured Housing - Replacement onl ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection/Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLYSERVICE'BILLINGS.TO: . :, er RECEIVED Name: N �� I Phone: MY C "woo Address: City /State/Zip: JUL 1 2 199 0 Water 0 Sewer 0 Metro 0 Standby PERMIT CENTEF CITY OF TUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 ProjeotiNumber:, Permit Numberi Miscellaneous Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. < >< `. ":APPLICANT= REQUEST' FOR" MISCELLANEOUSPUBLIC :.WORKS.PERMITS ❑ Channelization/Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage Cl Curb cut/Access/Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading/clearing R anitary Side Sewer #: C71 Sewer Main Extension 0 Private 0 Public treet Use C3 Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt # Size(s): ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous ❑ Moving Oversized Load/Hauling 0 Deduct 0 Water Only WATER' METER: DEPOSIT /REFUND'BILLING Name: NYC Address: Phone: City /State /Zip: RECE JUL 12199 Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure wlIW6WILA reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. PUBLIC WORMS Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: iV►>)1J 12, I0‘94, MISCPMT.DOC 7/8/96 Date application expires: \IM•hriR R:y I2, t' 1 Application taken by: (Initials) N►tt� BUILDIN O : • ' • • 4 HORIZED AGENT: . Signatur= , Antennas /Satellite Dishes Date: i7 f�1 Print na ad • , dor Phone:.1 4 z8- 2 46 Fax,: 1 42'7Z� Address: I 3Z Pl iesr 4MNE . 440 Ciryit a WA 'tait) f ❑ SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground,Tanks/Water -Supported directly.upon grade ; exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2 :1' . PERMIT REVIEW : Submit' checklist' No M ❑ Antennas /Satellite Dishes Submit checklist .. No: M -1.. ❑ Awnings /Canopies - No signage Commercial .Tenant Improvement Permit : .. ❑ . Bulkhead/Dock , , ,Submit checklist v No: M -10:' ❑ • Commercial Reroof Submit checklist , No: M 6 ❑ Demolition. , , ; 'Submit checkiist; .• N 0:,.M - 3;'.:M - 3a ❑ Fences -,Over 6 feet in.Height• ' . Submit'checkiist INo :• : M =9:' '; ❑ Land Altering/Grading/Preloads Submit checklist No: M -2 ❑ Loading Docks Commercial Tenant Improvement Permit. Submitchecklist No: H -17 ❑ Mechanical:(Residential & Commercial) Submit checklist. ~• No. M -8; H -6, H -16 • . . ❑ ' Miscellaneous Public: Works,Permits.., See Public,Works Submittal Checklist. .H -9: i� . ❑ , :ManufacturedUHousing :(RED INSIGNIA ONLY) • Submit checkiist ? N o, : >M -S • ... ❑ Moving Oversized;Load/Hauling Submit checklist; No:.:,' M 5 . ❑ ParkingiLots ,Submit checklist No: M-4 : ❑ • Residential ::Reroof.,- ;Exempt.with following exception : -1f roof structure to be repaired or replaced: • . Residential•Building Submitchecklist No: M -6 ❑ Retaining. :Walls - Over .4 feet in height Submit checklist No:. M -1 • ❑ Temporary . Facilities:: Submit checklist:. No.; M -7.. ❑ Temporary:Pedest`rian Protection/Eitit Systems ;Submit checklist; Noz M 4 Cl Tree: Cutting . " Submit checklist: °.No: M -2.. ALL MISCELLANEOUS PER APPLICATIONS MUST BE SUBMI D WITH THE FOLLOWING: • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN > BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED > ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT • STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER • CIViL/SITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder. OR submit Form 1 "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architeci/engineer, or contractor licensed by the. State of•Washington, .a.notarized.letter from the property owner authorizing the agent to submit this permit application and obtain the . permit will be required as part, of thls submittal. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY O ER URY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. / 11 1 MISCPMT.DOC 7/9/96 PW9c:.02W.'d i;tPtut; Pi'oi.t,st: DETROIT i1. 8,Y8 o '; 10N7 01 IN FRONI OF 10842 ' 'f r 0 11.1. Farce:I 0 d:12:J04-9172 Nt VAL VOL L Contri,ctQY TrA4101 60VOI1 AUTOMAILD L084 EAST 11140AL kY fliOaifi OWOEV D1W)OHT! PHFV.INt 1,0C 0161. ELLIOrt f:!VE. DP7.4909, ROP,. Of4NC. REVIP APCHifnT PO'r: wrlow 1932 FIR AV-8UtIE 616, ::Ekl NA COKIACT no W11131-11 Phcine: FIRS AVE 8 611,— '..3Er,rfLE kt; 1 :'. Add POPOit De OF FiGki OF NAV TO CPEOL OF EXISTING BUSINESS. Existing Square Feet: Additional Squal'e Feet: New Square Feet: Inspection Fee: Plan Check - Fee: TOTAL FEES: ucH, King County'Valuation: Value of Constuction: .00 **k**44.4,Ak**,44*k***4,*k***,4**4 , *44*4 k*4 44.44.*A****.4 444,0444 444k44444.4444.44,4A444.-44,44 I hereby accept this permit and agree to abide all applicable sections of the City of Tukwila Municipal Code. We agree that the City of Tukwila shall be held harmless for all or any claims arising as a result of this project. 'Permits which have :lapsed beyond the expiration date shall require re-application and re issuance of the permit through the City at an additional T ee. THE APPLICANT MUST NOTIFY THE cIn INSPECTOR OF COMMENCEMENT AND COMPLETION OF WORK AT LEAST 24 HOUR; IN ADVANCE. TO SCHEDULE AN INSPECTION CALL 433-0179. 15.00 10.00 25.00 Signature Date: `1.(D A**A*AA4 44 **4 .44*4 4 i k*k le4***kwA*4*AA**10;r41 4 *44 'i,44**444*444,444,4.4kk*'4 APPROVED FOR ISUANCE BY: JJS Issued Ev: Authorized Permit Center Signature AA*4444444,4 4 4 4,44444*****444**4 4 x4 AA444, -4 k4 ,44 I hereby certify that the permit holder whose name and address appears on this record has satisfactorily met the standards and conditions for the project approved herein. Final Inspection Approved: Acct Nc: 000/342.400 Acct No: 000/345.830 Inspector Signature Date CITY OF TUKWlLA Address.: 10847 EAST MARGINAL 0Y S St: 01 Permit No: PW96-0200 Suite: Tenant: DETROIT AUTOMATED SYSTEMS Status: ISSUED Type: 9W-5U Applied: 07/12/1996 Parcel #: 032304-9172 Issued: 09/09/1996 +*AA^w++**+*+^a*+**w+****+�*+w^**+*****+*4-0,**++*kw^**+4^^*+^+***^^+^**^°^ Permit Conditions: l Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation off- site or into existing drainage facilities. 2. Work affecting troffYcf7Ows shall be closely coordinated with the City Uti].ities InsPectnr' Traffic Control Plans shall be sub tted to the Inspector for prior approval. 3, NEW LANDSCAPE ' A/EA.SHALL BE REMOVED AT OWNERS EXPENSE WHEN CITY.STREET IMPROVEMENT PR0JECT COMES ALONG. 4. AREA BETWEEN THE PROPOSED LANDSCAPING STRIP & EDGE OF EXIS- TING ROADWAY' SHALL BE DESIGNATED AS NO PARKING AND 'NO PAR- KING SIGNS PROVIDED AT DEVELOPER'S EXPENSE. 44, * *A *A* k•A *k *•k k:k *k * *k•A kAk* 14*4 k *••5 k-A l*•kk:4•kkkk A 4 DLL CITY OF TUKWILA. WA TRANSMIT •. k**•** A*# k*****• kk• A.k k*h******* kAk* k*• k+ r)• hk• t*** A* sk•k.4•k*i **k•Ak TRANSMIT Number: R96 00475 Amount: 25.00 09/09/96 00 :35 Payment Method:' CHECK Notation: AUTOMATED EQUIP Init: MEV Permit No: PW96•-020() Type: PW -SU STREET USE Parcel No: 032304.9.72 Site Address: 10847 EAST MARO[NAL WY S St: 01 F1: Uri: Location: IN FRONT OF,10847 EAST MARGINAL WY f3 PARTLY IN This Payment 25.00 Total Fti'es: Total ALL Pmts: Balance: *%**frklt4**A*A *•k*. * * *►.:4k*A* A***•A*•A*A*A* •**Alik.A **•A ** *•-!r k• Account Code Description Amount 000/343.830 PLAN CHECK - UTILITY 10.00 000/342.400 INSP FEE - UTILITY 15.00 2'5.00 25.00 25 �.r .00 2993 09/09 9617 , TOTAL 25.00 y GENERA 375.00 1. AA*fi A * A* A* A, 4* A**** A,Ak: 1*• k* r** k •Ai : #• *►• *A?4* *AAivk - A - *A.Atr* 1rAiA).4*i,A.*A TOTAL 375.00 O �:1/ OF TUKWILA. !v t3 �, — Ak f� I TRANSMIT I l CHECK 375.00 , � j k '�itAN CHANGE 0.00 • AA k• 1 : * *41•*•:*itivIkit4:ic**4#•A *.1 *•Ak A •k ••A* • * *k # !•.•*Aitic. *A•'A *•* rpNldS14I•f Number: 96004039 Amount: 3 04/24/ 5 1 : 4 `� A000 I5.14 Payment Method: CHECK Notation: AUTCth( -YiED EOUP Init: KOP Permit Na: 896-0111 Type: 4)- -k 1J)G BUILDING PERMIT Parcel No: 032304- -9172 Site Address: 1 0C4q' EA T MARGINAL WY S 10t47 Total Fees:: 932A4 This Payment 3Y5.00 Total CALL Pmt:.. 373.00 Balance: 37 7 ,. 84 k**•**:*. A*** kA?** k *1.** *:*•k ** * *htsck*k—AA *1.*:;k 4**k4***4* ** * *A *4* **1:*4h* • Account Code Description Amount 000/345.830 PLAN CHECK -• NOIRES 3 *?5.00 0 Account Cod* Deocription 000/345.830 PLAN CHECK - NONPES 000/322.100 BUILDING - NONRES 000/386.904 STATE BUILDING SURCHARGE 0 *^k^*A+A**+a461, ITY OF TUKNILA, NA TRANSMIT .*^*):+*4.**.,%;+^*4+�a**+*+****ka*ah+k+*A+*«++ TRANSMIT ��mber: 96004147 Amount: 577.84 05/15/9 3 123 Pavmmnt Method: CHECK Notation: AUTOMATED EQUIP ]nit: SNC Permit No: G96'0111 Type: D-8LDG 8U1iDING Pf:kMIT Parcal No: 032304-9172 Site Address: [AST hARG%hAL WY S iac-{/ Total Fees: 952.84 This Puyment ':;77.84 Total ALL Pmts: 952.G4 Ualdnce: .00 ,/++A~*^++**^}*A*+*0.+*^*^�klk* Amount -1.41 574.75 4.50 GENERA 577.84 TOTAL 577.84 CHECK 577.84 CHANGE 0.00 5464A000 16:02 ,.. 'yr •••'' ',Z "—' Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: FINALAPP.FRM L City of Tukwila Fire Department Authorized Signature ' • • * ` • •' ,• • ' John W. Rants, Mayor Thomas P. Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Permit No. Project Name .7)(0/ A/tyktetA-c/ S Address /05 Q-37 / eftt/ _S Suite # Date/ T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 Project: Type of inspecti. : Address: Date called: Special instructions: roa 1' / /' 1 C p(>e,S�`�JK ' Date wanted: / 7-9s_ a.m. CL R eques t er: Phone No.: L— INSPECTION RECORD 1 Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PE'M T )// 0 -4x670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: . c I to $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: ( , 1'��� -41 i A t cr Y r r O Type of inspection t"1 VA'`....— Addres a rh (n/ Date called: 7-/ Special instructions: 2. ` � Cie-- V ( Date wanted: -7- to , 9(..f P.m. Requester: Phone No.: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: Inspector: INSPECTION NO. INSPECTION RECORD Retain a copy with permit Approved per applicable codes. [I Corrections required prior to approval. Z ___Ede..___(21,./.] - )h 2- 4.r -,.7 ' eel it s t� h PERMIT NO. (206) 431 -3670 Date: 7 / V.t $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: dl?,� CGt' ,ia t,, i r". Oevd jL s N U 1.1/ risk N S16, I.) J vI ikk to g-c-"r•OS , '' 714IS D tnwsr (t< Ai ►J %01,Acv b 0v./4*1G dust wis 1-k ultS Special instructions: / ' (..kw 6,,bl1: .V1,o % JAIJD L (J. ND SG etrLw.,T Projec�y �i j dl?,� CGt' Type � -111 : a � Address Date called: ��- Special instructions: / Dat am. s r" �' 021 , Requester: h ��� V � / Phone No.: al'--- 9 i /) CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector: INSPECTION NO. INSPECTION RECORD Retain a copy with permit (206) 431 -3670 Approved per applicable codes. [ Corrections required prior to approval. Date: id � r l l9 $42.00 REINSPECTION FEE REQUIRED. Prior to inspec ion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: Avcrve n Te of inspection: Type G G\.4 Address:oM �'^^� A Date called: Special instructions: V Date wanted: — ( 1 q� I a.m. p.m Requester: Phone No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 )q(4. 0111 PERMIT NO. (206) 431 -3670 [pproved per applicable codes. I Corrections required prior to approval. COMMENTS: rJO SuSP. Ci ? &-I r1 C 1/J 1S T.I. Inspector: Date: ii j $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: Project: � < i r r A w,k-rej Type of inspection: C -B Address: Date called: Special instructions: G i i ► &r Tfl7 tJG Date wanted: 6 - 7.- 9�0 p.m. Requester: Phone No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188, ( 296 PERMIT NO. (206) 431 -3670 Approved per applicable codes. F Corrections required prior to approval. COMMENTS: 1 r7/Lc Inspector: _ 7 Date: 077/, / g ) $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. I Receipt No.: Date: r ect: Type of inspection: i Ls rAgfiViNe1 RaT a�7Q44ATO 9 6103 Addr s lo�sa7 s: IEpa MA ►AAL wY 5 Date called: -� `5'3 I - `t Special instructions: Date wanted: — 3 _ 9 t „ ono p .m. Requester: ` F DEA* ° I9L1 - DtcS(0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 1 :` 6300 Southcenter Blvd., #100, Tukwila, WA 98188; • PERMIT NO. (206) 431 -3670 COMMENTS: U s kr Inspector: Date: (604 9 Approved per applicable codes. Receipt No.: Corrections required prior to approval. $42.00 RE INSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: ` 2' 11sd::' n7 t�'t t; t�irS .Yc:.d,.<t9� _ .. aLr i�. d,: t.. :,'.�.Yi�Si�..i�1L�'iF. >.�h',F. t...c.il....�x.._t.�o �,... Yd .c __. S T roject: tgoir AUTDAAATet) 915V/6 Type of raction: l, ItQlx.1-- tu s: 1 6 WI 5 Date called: 5 2" 9 (0 Special instructions: Date wantet ..... _ Requesteri (VIM qqq - 0656 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit t PERMIT NO. (206) 431-3670 COMMENTS: Corrections required prior to approval. Inspector: cIII- Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ,Project: WZDIT IAIROA9M) Type of inspection 1130 tAddress: : 7 FAST AlAtidiAL W Y 5 DI - Date called: ', - 2 -9 (0 Special instructions: , Date wanted: P.m. Requesterj— F - F P egon criq - 0 (05(0 ..••••••••••••••••••••••••* I I INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 C MENTS: • Inspector: Date: 5 Approved per applicable codes. r eceipt No.: INSPECTION RECORD Retain a copy with permit Date: (206) 431-3670 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Dear S i r : City of Tukwila Fire Department Fire Department Review Control #B96 -0111 (512) May 7, 1996 inn Re: Detroit Automated Systems - -$8.4` East Marginal Way South The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "A11 Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Maintain fire extinguisher coverage throughout. 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 57544139 Page number 2 City of Tukwila r Fire Department Thomas P. Keefe, Fire Chief doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Obstructions, including storage, shall not be placed in the required width of an exit, except projections as permitted by the Building Code. Exits shall not be obstructed in any mariner and shall remain free of any material or matter where its presence would obstruct or render the exit hazardous. (UFC 1203) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207.1 - 1212.8) When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) The color and design of lettering, arrows and other symbols on exit signs shall be in high contrast with their background. Words on the sign shall be block letters 6 inches in height with a stroke of not less than 3/4 inch. (UBC 1013.2) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) 3. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 Page number 3 City of Tukwila Fire Department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Sprinkler systems shall be maintained in an operative condition at all times. Sprinkler systems and their component parts (including hose stations) shall be inspected and tested per N.F.P.A. 13, N.F.P.A. 14 and N.F.P.A. 25 at a minimum frequency of every twelve months. A copy of inspection, test and maintenance records shall be forwarded to the Tukwila Fire ' Prevention Bureau. Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 5. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 -4404 • Fax (206) 575 -4439 L City of f Tukwila Fire Department Thomas P. Keefe, Fire Chief Page number 4 Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition,and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 :'r ,'P $TR fl9M ', ' •` '•r 'GXXf?6W10NDRT! , ..Q:1 •':' :...:7.1': AUYQ$ECGS$PO a6 f.F.0( ;9.6- 5 -15 -1996 12:57PM FROM DETROIT AUTOMATED 2066246401 c PLEASE DETACH AND SIGN CERTIFICATE BEFORE PLACING IN BILLFOLD '!iican tao AS'PIIW�ED B Y (:MK A5' , • • EeNS #> �DNT�i:' .':GEME1tAL'_' i i , , , ..,..:.r.: ,..,....,......., . ) `�'AUTOMA ? =ED.'' EQU CO.4 1:14C......"::' • .." I 904 1ST AVE S • ' 1 'SEATTLE WA 9813 SIGNATURE ED BY DEPA ENT OF LABOR AND DUSTRIES i. MAY 1 51996 ,PERMIT CENTER P. 1 F626.062.000(342) RECEIVED CITY OF TUKWILA' ' • EXISTING BUILDING FRONT YARD ETE3ACK • L ADUW EXISTING G LINE OF EXISTl ROADWAY EDGE TD EWE /T1' . E NEW EXTRUDED asS-I,aLr cures GENERAL NOTES L DRAWINGS INDICATE GENERAL TYPICAL DETAILS OF C0NSTRJCTIOII1 1111111RE CONDITI0N6 ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN OR NOTED, SIMILAR DETAILS OF CONSTRICTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY ARCHITECT 2. PERFORM ALL WOW IN ACCORDANCE WITH APPLICABLE CODES AND IWEGAJLATIONS. THE CONTRACTOR 18 RESPONSIBLE FOR COORDINATING ALL NECESSARY tNSPECTi0N6 AND APPROVALS FOR THE APPLICABLE GOVERNING AUTHORITIES. • LOCATKt1 OF EXISTING CONSTRUCTION 16 SHOWN BASED UPON AVAILABLE A6 -BUILT INFORMATION. . THE CONSTRUCTION SHALL NOTIFY THE ARCHITECT OF ANY SIGNIFICANT DISCIQEPANCIES BETWEEN THE DRAWINGS AND ACTUAL CONDITIONS. THE CONTRACTOR SMALL VERIFY ALL EXISTM CC44DITICN6 PRIOR TO THE COMIDCEMINT OF THE WORK 4. DO NOT SCALE THE DRAWING6 FOR DIMENSIONS. WERE THERE IS A DISCREPANCY BETWEEN WRITTEN Dre4/31O0 AND ACTUAL CONDITIONS CONTACT THE ARCHITECT FOR NIE1Wf'RETATI0N. CODE DATA KIP COUNTY ASSESSOR NO 032304 - 9112 -0 ZON & MANJFACTURIFCl/A 5TRIAL CENTER - HEAVY (MIC/H) DISTRICT LEGAL DESCRIPTION: PORTION CF SW U4 OF SW V4 CF SECTION 03 BEGLFNNG AT SW CORER OF SECTION, THENCE NORTH 60 FT, THENCE 8 W 51' 20' E 530Ai FT. TO WESTERLY MARGIN OF EAST MAMMAL WAY NO CAE N0RMESTERLY ALONG MARGIN THE WESTERLY MASON 65341 FT. TO THE POINT OF BEGN4P (PONT 'A') THENCE CONTNU NG NORTWESTERLY 21103 Ft. THENCE 616' 05' 00' 1111424 FTT. THENCE 610 30' W 250 FT. tM/l. TO INTERSECT A POINT MICH BEARS 8 69' 30' SO' WOF THE POW OF DEWING THENCEN85'30'50'E TO THE POINT CF BEGIINNMG. 1Detroi 14utoma ATA NOTES ASSESSOR NO. 032304-9112-0 ` ICATE GENEIMI. TYPICAL DETAILS OF CONSTRUCTION. WHERE NOT SPECIFICAUX INDICATED BUT ARE OF SIMILAR TO DETAILS SHORN OR NOTED, SIMILAR DETAILS CF SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY WORK IN ACCOIQDANCE WITH APPLICABLE CODES AND THE CONTRACTOR 18 RESPONSIBLE FOR COORDINATSIG INSPECTIONS AND APPROVALS FOR THE APPLICABLE AUTHORME&: EXIiING CONSTRUCTION 18 6140U4 BAKED UPON AVAILABLE TION. THE CONSTRUCTION SHALL NOTPY THE ARCHITECT IFTCANT DISCREPANCIES SEMEN THE DR4IUA1GB AND ACTUAL THE CONTRACTOR SHALL YENIFY AU. EXISTING CONDITIONS CO T E310EhENT OF THE WORD THE DRAW808 FOR DIMENSION& DIMENSION WHERE THERE 18 A BE11LEEN WRITTEN D11't1N810N8 AND ACNAL CONDITIONS ARCHITECT FOR MTERPMTATION. ACTURM+I /INDUSTRIAL CENTER - HEAVY (MICM) DISTRICT 10TION: 1/4 OF 811) 1/4 OF SECTION 03 BEGIMING AT SW CORNER OF SECTION, THENCE THENCE 8 S8' $I' 20' E S30Ai FT. TO ILEBTERL.Y MARGN OF WAY THENCE NOR?HMLESTERLY ALONG MARGIN THE WESTERLY 1 F? TO THE POSIT OF BEGINNING (PONT 'A') THENCE CONTINUING Y 21189 FT. THENCE 816' 03' 00' W 1 429 FT. THENCE W 2S0 FT. M/L. TO INTERSECT A POINT WHICH BEARS W.OF THE POINT OF BEGMVNIWG THENCE N 89' 30' 50' E OF BEGINNING. Detroit Automated stems SITE PLAN SCALE: 1' • 20' • • MIND These plans have been reviewed by the Public Works Department for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards or ordinances. The responsibility for the adequacy of the design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. �cptance is subject to field inspection by the 1 ,;J :ic Works utilities in sector. Date: / By: t F( 0200 MI0•01 I I ECT HT, JR. NGTON RE JUL T PUBI F1A) 0200 i4i-OiiI cer These plans have been reviewed by the Public Works Department for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards or ordinances. The responsibility for the adequacy of the design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Finn' n- is subject to field inspection by the Works utilities in sector. Date: - 1 By: RECEIVED JUL 121996 TUKWILA PUBLIC WORKS 10841 East Marginal Way South Tukwila, Washington 98168 Site Improvements Date 1/3/96 CONTENTS: SITE PLAN Issue / Revision Permit / Bid Set DATE *MAb d1�T� 4-1 RECEIVED CITY OF TUKWILA JUL 1 2 1996 PERMIT CENTER ... ■ SITE PLAN Brill F I" • 30' NORTH PJ:WO((1 PARTITION SCHEDULE FLAN INDICATIONS/PARTITION TRPE5 NO4 LOAD BEARHY• PARTITION 1 HR - UL 0E51014 NO. 11466 t. NON LOAD BEARING PARTITION I HR - UL DESIGN NO.11451 NOTES: NON LOAD BEARING PARTITION e' 0' HIGH WALL NON 1.0AD BEARING PARTITION 14O4 LOAD BEARING PARTITION PLAN INDICATION PARTITION TYPE 3 8/8" MIL. MUDS, 35 GA MIN, • 24' Oa (MN) WALL TYPE TRANSITION INDICATION 5/e" TrPE 'k' GYP. BD. APPLIED AT RIGHT ANGLES OR PARALLEL TO EACH 813E OF FETAL 811.135 W/ 1" TYPE 5 DRYWALL 8015(18 5" OD. ALONG EDGER AND 12° 0.C. M THE FIELD OF THE BOARD. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24" EACH BIDE AND OPPOSITE 81058 3 8/8" MTL. 81(105, 25 GA MN, • 24' 0G (MX) 3 I /4" BATT INSULATION 5/5" TYPE 'X' GYP. BD. APPLIED AT RIGHT ANGLES OR PARALLEL TO EACH BIDE OF FETAL STUDS W/ I" 1r15 5 DRYWALL acme 8" OD. ALONG 53488 AND 12" O.C. IN THE FIELD a THE BOARD. STAGGER ALL VERTICAL AND HORIZONTAL JOINT6 24" EACH SIDE AND OPPOSITE 51DES. 15/8" MTL. 53305,28 • 24° 0C. 3 I/2" x 12" WIDE 8/5" GYP. B.D. FASTENED TO 81208 W/ 3 TYPE 8 DRYWALL emus AT EACH BIDE, SPACED 48" OD. VERTICALLY (MAX). OR BRACING CUT FROM R.NNE58, 9 1/I' LONG, FASTENED TO MTL. STUDS W/ 2 N0.8 BY 1/2" SELF - DRLLR G 8ELF- TAPPING SCREWS M EACH 51113 5/8' TYPE 'X' GYP. 130. APPLIED AT RIGHT AIGLE5 OR PARALLEL TO EACH SIDE OF METAL STUDS 13 I" TTP5 6 DRYWALL SCREWS 5" OD. ALONG EDGES AND 12" OD M THE FIELD OF THE 90448. 5TAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24" EACH SIDE AND OPPOSITE 81DE5. 3 3/8" Mt. 83335, 25 GAMIN, • 24' or.. (MN) TRIPE 'X' GYP. BD. PROVIDE TRIPLE 5334ER MACK AT TOP OF WALL FOR BRACING 3 3/5° MIL. MUDS, 25 GAMIN, • 24' 00 (MM) 3 I/4' WA77 INSULATION 5/8" TYPE 'X' GYP. B3. 3 I/4" BATT 543/1LATIO14 35/8" MIL 512105, 25 GAMIN, e 24" OC. (1154) 5/8° TYPE 'X' G1P. BD. L PROVIDE 81-IP ANCHORAGE AT TOP CF WALL AT ALL RILL HEIGHT PARTITION5. PROVIDE 25 GA MIL CEILING RIVER W/ 3° OR 4" LEGS OFFSET AT MIDPOINT TO AGA:M r/ATE GYP. BD. MIMEOS. ATTACH TO UNDERSIDE CF 81131016RE W/ FASTENERS SPACED 24' Oa AT 1 -14R RATED PARTITION P4840E GYP 133. AT RIMER OVERLAP WALL GYP 50.114" MINIMUM. 2. C0 4515140TI0N OF FIRE RATED PARTITIONS INDICATED ABOVE, INCLUDING TAPING AND FINISHING OF GYP8M1 BOAR) FOR RILL HEIGHT TO STRUCTURE ABOVE, 814 XL BE 34 ACCORDANCE WITH THE REFERENCED ASSEMBLY RATING NL3113ER 3. SOUND- 180LA110N PARTIT10148 SHALL BE SEALED AIRTIGHT FOR FULL HEIGHT. TAPE AND F114184 ALL JOINTS AND FASTENERS. CAULK AT PERIMETER AND AT ALL PENETR4TIO318. GENERAL NOTES I. DRAWRGB INDICATE GENERA. TYPICAL. DETAILS OF CONSTRICTION. WERE CODI11GN8 ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHAR401ER TO DETAILS OHO154 OR NOTED, SIMILAR DETAILS O: CONBTRLT1031 SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY ARGI411145T. 2. PERF0R1 ALL WORC M ACCORDANCE 51T4 APPLICABLE CODES AND REGULATION& THE CONTRACTOR 18 REBPON8IBLE FOR 4400RDMATRYa ALL IECE88ARY 5+8P50TIO318 AND APPROVALS FOR THE APPLICABLE GO15 5ING Al1TNORITIEB. 3. LOCATION 5f E8101310 CO48TR1CTIOT4 15 BHOBN BASED UPON AVAILABLE A8 -BUILT INFORMATION. Ulf CONSTRICTION SHALL NOTIFY THE ARCHITECT OF ANY 81GNRICANT DISCREPANCIES 5572551+ THE DRAWMG8 AND ACTUAL CONDITIO316. THE CONTRACTOR SHALL VERIFY ALL EX151NG CONDITIONS PRIOR TO TE COMMENCEMENT OF THE WORK. a 5. DO NOT SCALE THE DRAWINGS FOR DR1F6e1ONB. WERE THERE 18 A DISCREPMICY BEILLEE5 WRITTEN DIMENSIONS AND ACTUAL camas CONTACT THE ARCHITECT FOR NIEFPRETAIIGN ALL CHANGES TO TIE EXISTING FIRE SPRINKLER 8Y5TB1 TO BE SUBMITTED TO THE CITY OF TIKWILA FIRE DEPARTMENT FOR REVIEW AND APPROVAL 5P OR00348 PRIOR TO 1248TALLATION OR 1001ICA1ON. VERIFY APPROVAL Reasaamta WITH 714E CITY a 11.141111.4 FIRE DEPARTMENT. b. NO NEW SUSPENDED CEILING SYSTEM PLANED FOR THIS PROJECT. CODE DATA ZONING, MANU'ACTURNG/INDUB1RAL CENTER - HEAVY (1110M) DISTRICT CONSTRICTION TYRE. V -8 (RALY BPRINCLEFED) OCCUPANCY, 8 / f -I (W/ WELDING OPERATIONS) SQUARE FOOT {GE: ALLCw4BLE AREA PER TABLE 8 -5 5 8,000 Ba. PT. F -I 500e Gan INCREASES■ x3 FOR AJTO1A11C FIRE SPREKLER SYSTEM PER 5053 5 24000 50. FT. P -1 24000 ea FT. PROPOSED AREA 5 2,154 e0. Ft.. F -I 5a6 80. FT. TOTAL 080 80. FT. OK PER 302.1 NO SEPARATION REQUIRED BTU B AND F -I OCCUPANCIES PER TABLE 3 -B. ONE HOUR CONSTRICTION PROVIDED BETWEEN 5 AND F -I OCCUPANCIES FOR WELDING OPERATIONS AT F -1 OCCUPANCY LEGAL DESCRIPTION, PORTION OF SW V4 OF 85 V4 OF BE0110N 03 BEGIR4MG AT 8W CORER OF SEC12O21HENCE NORTH 60 F1.11.10105 888' S1' 20" E 830.46 FL TO 5551ERLY MARGIN OF EAST MARGS1A1 WAY THENCE NORTHWESTERLY ALOHY• MAR3N TIE WESTERLY MARGIN 65341 FT. TO THE POINT CF BEGINNING (PONT 'A') THENCE CONTINUING NORNE8T5R.Y 21139 FT. THENCE 016' 03' W 51433 FT. THENCE 9 10' 20' 30" W 250 Fr. M/L TO INTERSECT A PONT WHICH BEARS 5 53 50' W CF 114E PONS OF BEG58NING THENCE N 89 30' E TO THE PONT OF 55555541 KING COUNTY ASSESSOR NO. 032304-9112-0 Check aPProv Olselel understand shat the P I Iian Cn„s r �l soy m H to er I'tu IaPno con - I,a> so1 ,111 R a owledged- ace, s copy et \ al' — ''' SEPARATE REQUI RED FO MECHANICAL ELECTRICAL P UMBING GAS PIPING CITY OF TUKWILA BUILDING DIVISION 4� ECEIVED CITY R OF NI(WII APR 2 4 1996 PERMIT CENTER Date CONTENTS: SITE PLAN/ NOTES DA1Fs 48536 SEM Detroit Automated Systems 10849 East Marginal Way South Tukwila, Washington 98166 Tenant Improvements Permit , a. Be, Ron WrIgITt 4 Aeeociates / Architects, PA 1932 First Avenue, Suite 616 Seattle, Was1Tington 98101 -1040 1206)125 -4248 FAX (206)125 -4212 A -1 FRONT ELEVATION SCALE: I/8".P -0" RELOCATE INSPECTORS TEST FOR B WALL AD 70 WALJACENT TO L 6 s REMOVE AND REPLACE EXIBTMO 8TCRE1RCNT OLAZMO BYSIE71 540 30ING NEW ENTRANCE DOORS,, KAMMER IRPAB 11 4510R APPROVED EX19754 EOUIVALOB (2' x 4-1/2° FRAME MEMBER91, MATCH APPROX LOCATION CPiLL OF EX1575)G MULLIONS PROVIDE TEMPERED BLAME AT W71D4L WITS ADJAC817 TO DOOR) TOP. FIRE 17041: catECTION FLOOR FLAN SCALE: I/8 ".i' -0" 178 -8. NEWS,' x 7' PAIR DOORS, 9545.E ACME UV "..SPACE CLOSERS, 81D. FlN9H FULLS 8V CYL5DER LOCK CLEAR INSULATED ELAZMO (TEMPERED) M0YL PAM. 70184w CLEAR&AZMs 26' -4' 26' -0' 26 Ws. NORTH 30 -1• 90' -6• 29' -7 13�1f. I" M2ULATED P.MA EXI8755 a• 4542 EXTERIOR WA1 Tr0. FLOOR CLEAN -CUT 48.442D ItR GLAZ52 Ib -0, EXRTINO RRE 44 4E 4' x 3' RECITE W: WIRE OLAZIN:t 20 MIN RATED. 19' -3• 11' -1° 4' -4• EXIBTINS EXISTMS p08TITYse•DIA W4LL8IT0 RE871aYA0'B B:KCiul 4 PL'£ FEFf4 iO I�MAIN CCLIL'Ft 17P - At R ES170X( OYP. B 0 . CEL./8' AT ^ 47 24 '045 AT1 TO SAS' SHOP AREA 829 8 G R 4 ORE M' 49 0. SUPPORTED N E ie AF BY EACH E AT 49' 45 REQUIRED, /97LNG 14 FIRED O' EACH RID BRACE AS Ti'FA HEATMs WET TO BE ROTATED AT VOTING ONE -NR 9..4. M p . LcCA1Ta1 DOOR RELOCATED 8 ��1 \ \\ ASSEMBLY FIRE Hoe rdtEVArsd \ 9' -4• 18'-4" 71'-11• 4'-7" 9'-4° 7'-4• F -7' 7'-3° FR vIDE RESILIENT CHANNELS AT RIGHT A1 TO WALL STUDS AT 24.00 AT watts SO/GATED 114 DASHED LINE 711.. ■ ii TOTAL OFFICE: 2,794 8P OPEN OFFICE U90 SP L T A 427 8F STORAGE 1197 MAIN ELECiRICA- DETRIBUTION PANEL RELOCATE EX1 FIRE 4408E PROVIDE 3 L9' BAIT INSULATION AT THE WALL RETAIL 1145 8P FLOOR MAIN WATER CLEAN -OUT 914I7.0F vALVE Tp'Y REMOVE AND REPLACE FLooR CONCRETE A aR . REWIRED FOR PEW SANITARY BELER NEW FLOOR DRAIN VERIFY — LreAnaa SIDE ELEVATION SCALE: I /8".I' -®" DUBTAB EX1a7MO OVERHEAD DOME ROOF DOOR cria PROVIDE 80 CR1 EXHAUST FAN DUCT THROWN 10041 East Marginal Way So. R CFA OvE Tukwila, Washington PROVIDE WATER MOUNT GYP. BD.IW 98168 EPDXY PAINT AT ra':B1RYKM WALLS 7TP. HEIGHT OF W4T34 CLOSET SHALL BE 17" MIN, 19' MAK MEASURED 70 TOP CF SEAT PT0.NT 59K UV 874 PE1047 AT 34' ASV. FINISH FLOOR FRONDE LEVER F41.037 CCNTROI. HANDLES LOCATED NO MORE THAN n" FROM Mar EWE CF SINK /1 PROv1DE INSULATION FOR EXPOSED WASTE AND 140T WATER PPM BELOW 5MK NOTE MIRd7R8 OR SHELVES SHALL. BE IN87ALED 81444 THAT THE Bomar cp MIRRJ'ROR TOP OF SHELF 18 LOCATED (17484 40" CP THE FLOUR ALL DRYLG 8821 ENT, 7410. OR OTHER DISPENSERS, AND DERMAL FIXIURE8 9T441-L 88 MONIED 50 AS To NOT EXCEED 40" AB0VE IT E FLOOR To ANY RACK OPERATMS CONTRAS RECEPTACLE, OR DI8PEN5ER B 77T TYPICAL RESTROOt I PLAN SCALE: 554'.P -0" AL13#441E DWR LOCATION ECENED CRY R OF NRNIfA APR 2 4 1996 PERMIT CENTER ON Detroit Automated Systems Tenant Improvements Deb CONTENTS: Stud RevIsran Remit Wel Set Ron W'Ight 4 A66Delatee / Archltectb, PS. 1932 First Avenue, Suite 616 Seattle, Washington 98101 -1040 (206) 128 -4248 FAX (206)128 -4212 FLOOR PLAN / ELEVATIONS DAM 4.95 MET, )4 -2