Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit B96-0114 - SOUTHCENTER MALL - BATH AND BODY WORKS - TENANT IMPROVEMENT
City of Tukwila L (c~' (206) 431•3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: 896 -0114 Type: B -BLDG Category: ACOM Address: 650 SOUTHCENTER MALL Location: Parcel #: 262304 -9004 Zoning: Type Const: II -N Gas /Elec: Wetlands: Water: N/A Contractor License No.: SHAMECC11ONJ Status: ISSUED Issued: 06/24/1996 Expires: 12/21/1996 Type of Occupancy: STORE Slopes: N Sewer: N/A TENANT BATH & BODY WORKS 650 SOUTHCENTER MALL, TUKWILA, WA 98188 OWNER SOUTHCENTER JOINT VENTURE ATTN: JAMES J GUDIN, 25425 CENTER RIDGE RD, CLEVELAND OH 44145 CONTACT TIM SCHENK Phone: 1- 800 -541 -0821 1120 EAST 80TH STREET *211, BLOOMINGTON, MN 55420 CONTRACTOR SHAMES CONSTRUCTION Phone: 510- 606 -3000 5826 BRISA ST, LIVERMORE, CA 94550 k * * * * * * * ** ******************* ************** * * * ** * *k * * *** *** * * * * ** * * * * * * *** Permit Description: REMODEL OF EXISTING SPACE IN MALL FOR NEW TENANT. SETBACKS Units: 001 Front: .0 Back: .0 Buildings: 001 Left: .0 Right: .0 Fire Protection: SPRINKLERED UBC Edition: 1994 Valuation: 98,000.00 Total Permit Fee: 1,447.84 *• k• k**k* k** kk*****k******* k****************** *k * *kk * * *•k * * * * * * * * * * * * * * * * * * ** Permit enter Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this p-• "t does not presume to give authority to violate or cancel the pro -'•ns •f any other state or local laws regulating construction or per ormance of work. I am authorized to sign for and obtain this bui,.'U". 4..rmit. (0%Signature: %�619���/� Print Name:_ Date: 4g.P• 2--y 614%; Title: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. r •• PA ME DE z : < s�st e7- : i f tE ` DATE� 1W rik , 40a rJ 1,1 s . ,� A�T�E.b' n� ; a . i ' zAPP.R'O:lw a � y �� = '4d1�Y.i3. p� : . . . ,�,^;;� < ,i+k�+:�::w:�;al.Jyx �;: �.2Yyi si y � Fri � � , l .1 QUIREME : ? RENTS / ;:C O E M M NTS • s ; ;! w 1 .�t ; r' 1 : .� X <.. . }.,' ?rtG"Lvo`R.�: =�.. V3evr., v. zq 3 ^- :.t�s!�s:�.6�ts,�f'Aoi�.iiN+, cF. a!':.�4�..�A q Plan Review Meeting Lt_ _q ( 5 I CRP DATE NOTIFIED INIT* - j ,f4 BUILDING - initial review 1iU (ROUTED) ONSULTANT: Date Sent - Date Approved - 2nd NOTIFICATION FIRE -/j 3 / qc, r =IREPROTECTION: / ''Sprinklers 0 Detectors 0 WA - IRE DEPT. LETTER DATED: s 7/ 4/ g 5. INSPECTOR: S/ / NIT:.1 0 ✓PLANNING i\-1 A AS- - 1 ZONING: pAR /LANDUSECONDITIONS? ❑Yes ❑ No �EFERENCEFILENOS.: INIT:, MINIMUMSETBACKS: N- S- E - W- psf PUBLIC WORKS • 5 -br_ / UTILITYPERMITSREQUIRED? 0 Yes ('UBLICWORKS LETTER DATED: J INIT: I X BUILDING - final review 51-16-6110 TYPEOFCONSTRUCTION: L Iv (j'Ptd..) CERT.OFOCCUPANCY? °Yes lallo UBC EDITION (year): 1 ct 5 2.k I NIT: K- L^ Al OFFICIAL l L ' ' • INIT: 77- I‘ AMOUNT OWING: 4, q . CONTACTED �-. rn I i DATE NOTIFIED 4 �, 1iU BY: (init.) 2nd NOTIFICATION BY: 3RD NOTIFICATION BY: BY: (init.) PLAN CHECK NUMBER fiQb DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. REVIEW COMPLETED CITY OF TUKWILA Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PROJECT NAME � ^/` Wor SITE ADDRESS SUITE NO. (050 .6 -Frr (1 INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N/A ", date and initial. 02/15/96 SITE ADDRESS ( (3 SUITE* Zr.)S!_1 L €r^(iL -'`K._ N1AL■ VALUE OF CONSTRUCTION - $ C4) 00D m PROJECT NAME/TENANT I34114 +-, t3004 . W Vlie- . ASSESSOR ACCOUNT # a ( 7 , 0 L - q O ati TYPE OF U New Building U Addition Tenant Improvement (commercial) U Demolition (building) WORK: • Rack Storage ❑ Reroof {] Remodel (residential) ❑ Other: DESCRIBE WORK TO BE DONE: fLE D0.01 TrNCr- SPA LC: Irk may.` Fat rJer4 T�var,r 7 • BUILDING USE (office, warehouse, etc.) NATURE OF BUSINESS; 4R__ SpL (SAT r-1 r 6001 L/.> . PL404US . WILL THERE BE A CHANGE IN USE? AV° ❑ Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: Tenant Space: Z•3:13 Area of Construction: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? Lid-No 0 Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: ❑ Sprinklers ❑ Automatic Fire Alarm System PROPERTY OWNER .JAC06 Tu _ C PHONE , dca_ a ADDRESS 2s42.S- a1a & D . QL 4m 4:J0 014 ZIP4yi4j CONTRACTOR PHONE ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT .3 0,rnES 0. t=-J �.4TC • PHONE 20€ .m s-, 04-5-0 , ADDRESS 10 t56i'` -- pJ?. • IJ�. g0 fS • BL.:-.1. ■-JA- ZIP cV$4Q-1 _ SEP 14 '95 12 :29PM TUKWILA DCD /PW brIN CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 llO 11/1r rrl 1 /1 I/ /) i )//1 «)/111'/ 1 11 / BUILDING OWNER OR AUTHORIZED PRINT NAM- .H r y\ 5 �N 1 ✓ — AGENT ADDRESS 1\2Q E • % SCI t TE 2.11 CONTACT PERSON S C 4 r CC—_ APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirement's. Application and plans must be complete in order to be accepted for plan review. ' VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior 10 application submittal. Contact the Permit Coordinator at 431.3670 prior to submitting application. in all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant Is other than the owner, registered architect/engineer, or contractor licensed by the State, of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the perrnit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. It you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431-3670. .DATE APPLICATION ACCEPTED L1 - q - q So Received Time 'Sep, 14. 1:28PM • s mIte � ' ' ..... p Y �w •. K >A;iT••• ��nY•'iY BUILDINu PERMIT APPLICATION DATE APPLICATION EXPIRES P.2 CITY/ZIP mlr4 'JOIN S R PHONE (.1 .SL .082 1 IC) —61 Print Time Sep, 14. 1:30PM k2wmaii Address: 650 'SOUTHCENTER MALL Suite: Tenant: BATH & BODY WORKS Type: B -BLDG Parcel #: 262304 -9004 CITY OF TUKWILA Permit No: 896 -0114 Status: ISSUED Applied: 04/29/1996 Issued: 06/24/1996 4 •4 •4 'k '4 •k k' - k * * 'k '4 '4 k '4 '4 '4 k * •k 4 •4 k 4 '4 'k 4 '4 '4 '4 4 '4 44 4 '4 •4 'k •4 '4 '4 '4 •k 'k k 4 4 '4 'k •4 '4 44 k 4 44 4 k k k 'k 4 'k •4 4 k k 4 •4 'k k4* k Permit Conditions: 1. PRIOR TO FINAL SIGN OFF APPLICANT 'SHALL SUBMIT METRO SEWER USE CERTIFICATION TO PUBLIC 'WORK FOR PROCESSING. 2 . No changes w i l l be made 'to the plans unless approved by the Architect or Engineer 'arid'the Tukwila Building Division, 3. Plumping permits 'shall be. obtained through the Seattle -King County Department of P,ubl is Hea1 th; Plumbing will he inspected bv.,;that',.agencv, includin± all gas pipiog (296 -4722) 4. Electrical.permits shall be obtained' through the Washington State D.i,v,ision of'Labor and Industries and all electrical worts w l.1 be inspected by that agency (248-6630).i 5. All mechanical work shall 'be under separate permit issued by the ,City.'of- Tukwila. . 6. All. - permits, inspection record • and approved plans shall be avai.lab ; le''e,t the job site prior to the start of any coil - str.ucti'on. ; These documents are to be maintained and avai l- able unt11 final in ::pection` approval is granted. 7. An_v. ;new cei 1 ing, gr.i.d and l i'ght fixture installation is re'quired._,to meet lateral brecing.requirements for Seismic on'e 3. U. Pa. ttition walls attached to: grid must be laterally br;ac.ed if over eight (t) feet in length 9. An,yexposed i.nsulations'backing; material shall have a Flame Spread Pat.inq ;'of 25 or less., arid' material shall bear ident i- f ica.tion .showi';lg the fire performance i tat ing thereof. . 10. A11'.,construction to be done in 'conformance with approved plans :and 'requirements of the Uniform Building Code (1994 Edition) as amended, Uniform Mechanical Code (3994 Edition), and Wa:liington :State Energy Code (1994 Edition). 1 1 . Validity Of Permit. The issuance of a permit or 'approval of plans, specifications, and .computation.' shall not be con - s.trred to be a permit for, or' an approval of, any violation of any of the ' pr•ov i s i ons of the bu i, Id i nq code or . of any other ordinance of the iuriudittion. ' No permit-presuming to give authority to v.iolat.e Or cancer the provisions of this code shall be v;a l ici. 12. VENTILATION IS REOUIREI :.FOR'. ALL NEW ROOM: AND SPACES OF NEW OR EXISTING BUILDING'S IN CONFORMANCE 'MYTH THE UNIFORM BUILDING CODE AND THE WASHINGTON STATE VENTILATION AND INDOOR AIR (QUALITY CODE. CHAPTER 51 -13 WAC. 13. There shall be no occupancy of this space until the final inspection has been completed by the TuIwila Building Inspector. , •.F A.:F * * :A :k •t * •k :A •k •k :k * :t * :k AA :k :1• •k :t •k h74k :F •�::t it :t f• A :k k h :t :4 A fi• ,1• * :t �r A * +c •A * •t k :l * • }'� k Y T I: N rl 9 h .r ti CITY OF TUKWI:L.A, WA : 4 1e•At *�ch:t:t *•.A*�t:1•d�Ak! •kk•k*+1t*:41,“'•k'k r 96004066 Amount: 560.59 04/29/W44 TRANSMIT Payment Method: CHECK Notation: ELDER-JONES Init: SLIT ,Permit No: 896•-0114 Type: B• -BLDG BUILDING PERMIT Parcel Ma: 262304 Site Address: 650 SOUTHCLNTER M(al.L Total Fees: 1.44 ?.84 This Pv:ment 560.59 Total ALL Punts: 568.59 Balance: 8. kA* *A *0.*k•A * *I:1A•k4 *k *k A* 14kz►• F: d/:+:• h.***7 1*. 4.1%•F.•*•F* *k *Ak* *•AAieh. *A*A 1:zk**A*A* D e s c r i p t i o n Amount PLAN CHECK K -- N13fi!KES 568.59 Account Code 000/345.030 : i*• A •:F;.*•A•h** *kk *A:A•**•A•k***4_ * A* ***,*AhAh * ***Ak*k*,A****A*4*•k4 * CITY OF TllKl+l7L.R, WA ikt:* TRANS II : A *A *k3h*hkk— A *****A••i•, • *4 1 *** trd:}•kk *A *.k 4 *h >t1•.1 ;'tk *:k:l #•A *+ TRANSMIT Number: 96004330 Amount: 879.25 06/24/96 14:'15 Payment Method: CHECK Notation: SHAMES CONSTRUCT Init: SI-B Permit No Parcel No Site (4ddrecs: This Payment 896t -0114 Type: B - -OLDG BUILDING PERMIT 262304-9004 650 SOLI1HCENTER MALI. Total Fees: 079.25 Total ALL Pmts: Balance: 1.44 1..447.84 .00 A *•h• kit}* ** *** *o1* *:A•AA* * * **** *.A * *k•A* **M*:1* * *t\* *A *431* * ** *kiW.A4•. *4* Account Coda Description; (Amount 000 /322.100 BUILDING - NONRE3 874.75 000/386.904 STAN BUILDING SURCHARGE 4.50 0696 06/24 9617 TOTAL 879.25 GENERA TOTAL CHECK CHANGE 5045A000 568.59 568.59 568.5 0.00 03:56 •••• , 4, ‘ (Mr 0,, • VA'.: • ' Ar '1 v'Ci , ..7":71r‘• 71•7 Project Name 1 A3 7 (xi/ toot/Ks 5 -5/e vivo Address Retain current inspection schedule X Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: City of Tukwila Fire Department TUKWILA FIRE DEPARTMiNT FINAL APPROVAL FORM -FZ Authorized Signature Permit No. FINALAPP.FRM T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Fire Chief 914- --owe/ Suite # 7 Da e Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575•439 Pro ct` n `, Typ of ,D ct ems � Address: 17 ca , Date called: Special instructions: a Date wanted: lab p.m. Requester: 0'Jq Phone No.: i lle7• .3.x'39 COMMENTS: -- INSPECTION RECORD 1 Retain a copy with permit INSPE TION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Inspector: P1 $4 r0 REINSPECTION be paid at 6300 Southcent Date: �E R EQUIRED. Prior to inspection, fee must Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 13A J ^ d- n- D t ' WoRI4s r 7 Type of inspection: �'� n Ad ress Date called: ? — 1 _�/'�� � Special instructions: at ante 96 a�m equester: .oS Phone No.: — .G 39 COMMENTS: Inspector: INSPECTION RECORD Retain a copy with permit INSPECT! • NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 c PERMIT NO. Approved per applicable codes. g Corrections required prior to approval. m J . •• 1%4'7'lil.:: i.. A.�..IY..✓_'K�I..ritM1 �: w ?;.✓.._•_S 7 .• . Date: (206) 431 -3670 ti $42.00 REINSPECTI • FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.,Suite 100. Call to schedule reinspection. Date: Receipt No.: Proq: A -, Type of,inspection: Address: 16,56 .6- J : i..e, , W i o Date called: 2 t o v Special instructions: - Date wanted: /q a.m. ','p.m. Requester: CD Phone No.' . .2yl. - x .53 R -' INSPECTION RECORD ' Retain a copy with permit INSPECTION NO. CITY TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 Approved per applicable codes. PERMIT NO. (206) 431 -3670 COMMENTS: I rl C L c^ b I tJG F1 tZl 7r- c'N?r'"a t1 „.Jt1 W r J WAUS Inspector: Date: / Corrections required prior to approvat . • $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: / � ��, �7 ype of i ed: ectibnG l � Addre� � ate called: �� � Special instruZ1io : `" /: e.7c' ' Date wanted: � a.m Requester: !L Phone No.: r IA Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 COMMENTS: Inspector: E Date: 2 $42.00 E INSPECTION FED REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: •'Li�A• '�f ..�.a3: `R�l�,�s t„�5..•::.z..a 5,4... . PERMIT NO. Corrections required prior to approval. {� F (206) 431 -3670 r v:.:. Project: / Type of inspectidn:;w•- f ~0, Addres Date called: Spe instructions: 4 :00-p/ L A Date wanted: / r �., / � � a.m. Requester: Phone No.: INSPECTION RECORD " Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable codes. COMMENTS: (206) 431 -3670 Inspector: Date: 7_ s,,, " Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6p,00 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: t, Date: .,.:r_•Cli..n.Sr <u�:. r..t. _ Project: elotth it _ god (lak5 Type of inspecticfn G(433 F64- Address: L tss) souihr.04 Y Date called: 1 ... _q ( Special instructions: rno Date wanted: —g--q V/ P.m. Requester: F Phone No.: 04 (0 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 pproved per applicable codes. COMMENTS: Inspector: INSPECTION RECORD Retain a copy with permit ' RR0-011(-1 PERMIT NO. Corrections required prior to approval. Incet.72f27 (206) 431-3670 Date: ri $42.00 EINSPECTION FE REQIJiRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: A P P1 VA L, - stAis v-t-t`- _it - t ) 61.4;t4 -11-4 CAL-- /� /PR.I %At-. z.} I'ttbvt 04 Gof i o 1n, -'.. o. S Cl-l1 -,c.A'r N . 9 J 4/4 c N1 G t,o' l- +-1 — rwt - (,./A SR/N4+— irk' Address: i 1,- h, 42 ik_G APPaavA L . S�14 ...- Pic- a.hprwAss i0 -1r,..- ,►S G C..3R-R., 0 Oa- L./AL- S .m. Special instructions: Requester: f"--. Project: � V�Kki Type of insgection: ? Address: S, C. NJ Date called: Date wanted: 7 5 9 Cs .m. Special instructions: Requester: Phone No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Inspector: C PERMIT NO. Date: 7'(3 (e (206) 431 -3670 Approved per applicable codes. Eij Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Receipt No.: Date: Use LPA' (W1R') Use' LPA' (Writ') Painting, welding, carpentry, machine shops 2.3 Police and fire stations' 1.2 Barters i . s, beaut sho._ 2 Atna (atriums 1 Hotel banqueUconterence/exNOilion hall" 2 Assembly spaceseauditonums, gymnasia'. tiieaiers Laboratories 2 Process plants 1 Aircraft repair hangars i.5 Re:Adihents/ ars' 1 Cafelenas, fast food establishments 1.5 Retail At° --} 1 1 1.5 0.6 Factories, workshops. i►arsdiirly areas 1.5 (.5 Retail 8 Retail banking - tricker andlor shower facilities Gas atdtiuns, auto repair 5t10pi !mild: tons 1 s Warrtraises star areas 0.5 0.4 Libraras 1.5 Aircraft storage hangars Ni ashy homes 1.5 1.5 Parking garages ei lotion 1'17 Wholesale stores (pallet rack shelving) Mall concourses 1.4 Plans Submitted for Common Areas Only' Schools build • s, school classrooms, da can centers 1.35 Common area, condors, bbbies sac • mall concourse 0.8 Laundries 1.3 1 allet laciaties and washrooms 0,0 - Office buildings, off rce/adminlstrabve areas In facilities of other use types (including but not untried to schools, hospitals, instltutlons, museums, conics, citurciies)s r n 1.2 1094 Washington Slate HoniesieeMia1 Enehgy cock Compwance isms Prescriptive Sprees Qualification Checklist Note: M occupancy typo Is'Olha' and fixture answer Is chocked, Ilio number of fixtures in 1ho space is not tiuiRus by Coda. Claim, ii nr.arn dhocn spacns on plans. If nol qualified. do LPA Calculations. 1994 Washington State Nonresidential Crier a Code Com.!lance Form Occupancy 0 Warehouses, storage arras 01 aircraft storage hangers G Olher Lighting Fixtures: 0 Check here 11 at least 95% of fixtures In the space meet ad four criteria: 1. Fixtures are fluorescent. non-lensed, with only one or two lamps, and 2. Lamps are T.S. T-6, T-8 or PL, and 3 Lamps are 5 -50 Wails, and RECEIVE CITY OF TU * ILA 4. Ballasts are electronic ballasts Footnotes for Table 15-1 Table 15 -1 Unit Lighting Power Allowance (LPA) for Interior Lighting 1. lit uses in which a usc is not mentioned specifically. the !brit Power Allowance shall be determined by the building official. This AM 1994 -- APR 2 996 PERMIT CENTER determination shall he based upon the most comparable usc specified in the table. See Section 1512 for exempt areas. 2. The watts per square loot may be increased. by t wo percent per foot ol'cciling height above twenty feel, unless specifically directed nihrrtvise by subsequent lon%nolcs. 3. Watts per square fool of nx►m may Lie ilicluisui u. 1::u percent per iii of cCiiing height ::.eve Ica 4. for all other spaces. such as stating and common areas. usc Ilic (hut Light Porter: allowance for assembly. 5. \Volts per square fled of room may be increased by teal percent pa toot of ceiling height above nine feel. 6 Includes pump arca under canopy. 7. In cases in which a lighting plan is submitted for only a portion ofa floor. a (Jail Lighting Power Allowance of 1.35 may be used for usable onice floor arca and 0.80 walls per square foot shall be used for the common areas, which may include elevator space. lobby arca and rest rooms. Common areas. as herein defined do not include mail concourses. 8. for the lire engine room. the Unit Lighting Power Allowanhx is 1.0 wans per square foot. 9. for indoor sport tournament courts wi111 adjacent spectator seating, the Unit Lighting Power Allowance for the court arca is 2.6 wills per square !tell iii. Vol A m id l Mail :3. light for iicc- aCuiding di +ii!3y, bail:.'irrC Glir.::.....c illumination end di:phiy wi nllitmIn11i1111 installed -"tin t' 1S feet or th w a r e exempt. 1 Retail A allows a limit lighting Power Allowance of 1.0 watts pet square fix)i. Ceiling mounted adjustable tuugsi at Italugc,i arid IUD mct chandisc display iiluntinariws ate cxuupt. Retail Bourns a Unit Lighting Power Allowance of t.5 watts pct square foot. including all ceiling mounted merchandise display luminaries. 11. Provided that a 'loot plan. indicating rack location and height. is submitted. the square footage Ibr a warehouse may be defined. for computing the interior Unit Lighting Power Allowance. as the floor area not covered by tacks plus the vcrtical fact arca (access side only) of the racks. The height allowance defined in lbotnole 2 applies only to the floor area not coveted by racks. • Project Info Project Address S0U'r'1 2ev)ter M,alI CJ Allowed Watts per 4' " ❑ Less than 60 % of the fixtures are new, and installed fighting wattage is not being Increased I Dale ui A i I 19119%y 1,0 2 h9� f 523 OR Parking II ��■ 1 . • • aff :�Ga!S5 ►. , h i. L. For nui mg Department Ilse KE: 13a k 3 , ,x1 lork -� 0ldg (by' f.rr:.Ide) Applicant Name: kt 1 L , � 1 . 4-C1 - n le _ 1 uo . ..a ■ e Ap; ticant Address. 116456 rock_ ' rock_ r., O � Z — Trac' L i . (' Oh Appticunt Phone: & i �) 682-- 119'3 Alteration Exceptions ((check appropriate box) U No changes are being made lo the lighting Allowed Watts per 4' " ❑ Less than 60 % of the fixtures are new, and installed fighting wattage is not being Increased I I LIA:abort (floor /room no) - v OI.cupallcy Description Allowed Watts per 4' " - Area in (1' Allowed K Area _ Ke .9.1 'aQ 1,0 2 h9� f 523 OR Parking II ��■ 1 . • • aff :�Ga!S5 ►. , h i. L. 42 . *. - 1 0ldg (by' f.rr:.Ide) 11 }• /A Bldg. (lay pt run) - n le _ 1 uo . ..a ■ e ��� _ ___ repra irmat-'ai1/ icr Total Proposed ::ails � =� Note: for building exterior, choose either the facade area or the perimeter method, but no both) Total Allowed Watts Z — Trac' L i . ... • - ' e _ .rs. 1 - '.4 -Rom T able 15-1 (over) - document all exceptions taken from footnotes Total A,no.ved VIlatts Z X19 Location (;roar /room no) Fixture Description Number of Fixtures Walls/ Fixture Watts Proposed _ (a 6 — R e ms' 1f- II 1 • lr .1 _, ' 4 xs , . W /R' 6 0 60 - OR Parking II ��■ 1 . • • aff :�Ga!S5 ►. , h i. L. 42 . *. - u.2 wrft' 0ldg (by' f.rr:.Ide) 11 }• /A Bldg. (lay pt run) - n le _ 1 uo . ..a ■ e ��� _ ___ repra irmat-'ai1/ icr Total Proposed ::ails � =� Note: for building exterior, choose either the facade area or the perimeter method, but no both) Total Allowed Watts Z — Trac' L i . ... • - ' e _ .rs. 1 - '.4 Atli Total Prepr_ed Wat '. ay not exceed Total Allowed :'alts for trite r Location - Uescnptton Allowed Watts per II' or peril Area in ft' (or 1I for perimeter) Allowed Walls x It (or x if) Covered Parking . W /R' OR Parking 0.2 vv/R' 1 Outdoor Areas u.2 wrft' 0ldg (by' f.rr:.Ide) u,26 Win' }• /A Bldg. (lay pt run) } 7.5 Will Note: for building exterior, choose either the facade area or the perimeter method, but no both) Total Allowed Watts N/A Location -- " - - Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed }• /A Total Proposed Walls may not exceed Total Allowed Watts for Exterior Total Proposed Watts 1.;J vvd511111 luk.oidie: iurlreslaental L-ner. Cod el,orn•Iiance Forrn Lighting Summary LTG -SUM I774 Wash.ngton Slab Nnnre$denbal l'neigr Coat CompI a,c. FMml i' ro'eci Descri ,Lion Compliance Option Maxiunum Allowed I.igii,linf~ Watt.* a (Interior hi•ixinnuiin Allowed Lit;htint. Wattage (Exterior U New Building U Addition Alteration Prescriptive t Lighting Power Allowance CI Systems Analysis (See uuauhcatlon checklist (over). Indicate Prescriptive d LPA spaces clearly on plans.) Proposed Ligi Laing Maid (interior) (May not exceed Total Allowed Watts for Interior) Prot,osed Li Win Waltaf;e ( Exterior) (May not exceed Total Allowed Watts for Exterior) �n I. ,ri• Project Address �uTh c.n. L X ► •' 1 Seat i . A• i • 1D call .. i - - - The following information Is necessary to cMck a lighting perm* application for compliance with the Ng a mp requirements in the 1994 Washington State Nonresidential Energy Code. Appticabitdy circle one LIGHT Code Section Inlomiation R . ed Location on Plans Building Department Notes • • action s no n.a. 1513.1 Local control/access Schedule with type. indicate locations ,^�' no n.a. 1513.2 Area controls Maximum Grail per switch J 1=/2 1513.3 Daylight zone control Schedule with type and features indicate locations yes no vertical glazing Indicate vertical glazing an plans es no XI overhead glazing Indicate overhead glazing on plans yes no agl 1513.4 Disptay/exNbrspeciat Indicate separate controls 1513.5 Exterior shut-off Schedule with type and features. indicate location s no n.a. (a) timer wrbackup Indicate location E12 ` ('D 2. s no b) photocell. Indicate location 1513.6 into. auto shut -off Indicate location yes no n.a. 1513.6.1 1) occup. sensors Schedule wilh type and kw..alions 12. s 1513.6,2 b auto. switches Schedule with type and features (back -up, ovemde capability): r tlrff, Indicate size of zone on tans 11 t ' , " . ections 1 - or 1 no L9hling Sum. Form TCompleted and attached. = v Schedule with f,xlu,e types, t.1 • r • • ' lamps, ballasts walls per fudure Cohort yes no n.a.l IElec motor efficiency {MECH -MOT or Equipment Schedule with hp. rpm, ernclency 1 WI 1 1994 Wash tington State Nonresidential Energy Code Compliance Form Lighting Permit Plans Checklist H!4 wifwmpon Sup Enemy Coen CnmpMOnee font LTG -CHK At Ilea no is circled for any question, provide explanation: Fire Department Review Control f#B96 -0114 (511) Dear Sir: City of Tukwila Fire Department May 13, 1996 Re: Bath & Body Works - 650 Southcenter Mall The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 108:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 2 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) M a i n t a i n fire extinguisher coverage throughout 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 1004.2) 3. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207.1-1212.8) 4. Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Obstructions, including storage, shall not be placed in the required width of an exit, except projections John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 3 as permitted by the Building Code. Exits shall not be obstructed in any manner and shall remain free of any material or matter where its presence would obstruct or render the exit hazardous. (UFC 1203) 5. Maintain sprinkler- coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. S p r i n k l e r protection shall be extended to a 1 1 areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 4.1.3.2.1) 6. All new sprinkler systems and all modifications to existing s p r i n k l e r systems shall have fire department review and approval of drawings prior to i n s t a l l a t i o n or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 7. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 8. When walls and ceilings are required to be of fire resistive or noncombustible construction, interior finish materials shall meet the requirements of Uniform Building Code 803. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 Page number 4 The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of The Uniform Building Code. (UBC 804.1) This review limited to speculative tenant space only - speciai fire permits may be necessary depending on detailed description of intended use. Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd City of Tukwila Fire Department A-Am John W Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575-4439 AC•ItO` CERTIFICATt OF INSURANCE PRODUCER J. F. ARENTS AND COMPANY 520 S. El Camino Real, 11342 San Mateo, CA 94402 (415) 342 -3095 (415) 342 -8789 FAX INSURED SHAMES CONSTRUCTION COMPANY, LTD. 5826 Brisa Street, Suite E Livermore, CA 94550 ~' ' ISSUE DATE (MM /DD /YY) • 6/04/96 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. COMPANIES AFFORDING COVERAGE COMPANY A LETTER in COMPANY B LETTER COMPANY C LETTER COMPANY LETTER D GOLDEN EAGLE INSURANCE COMPANY COMPANY E LETTER COVERAGES THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. CO TYPE OF INSURANCE POLICY NUMBER POLICY EFFECTIVE POLICY EXPIRATION LIMITS LTR DATE (MM /DD /YY) DATE (MM /DD /YY) GENERAL LIABILITY GENERAL AGGREGATE S COMMERCIAL GENERAL LIABILITY PRODUCTS•COMP /OP AGO. $ CLAIMS MADE OCCUR. PERSONAL & ADV. INJURY $ OWNER'S Si CONTRACTOR'S PROT. EACH OCCURRENCE $ FIRE DAMAGE (Any one lire) $ MED. EXPENSE (Any one person) $ _ AUTOMOBILE LIABILITY COMBINED SINGLE $ ANY AUTO LIMIT ALL OWNED AUTOS BODILY INJURY SCHEDULED AUTOS (Per person) $ HIRED AUTOS BODILY INJURY $ NON•OWNED AUTOS (Per accident) GARAGE LIABILITY PROPERTY DAMAGE $ EXCESS LIABILITY EACH OCCURRENCE $ UMBRELLA FORM AGGREGATE $ OTHER THAN UMBRELLA FORM D WC339523 -00 1/01/96 1 /01 / - 7 X STATUTORY LIMITS WORKER'S COMPENSATION EACH ACCIDENT 5 1000000 AND DISEASE — POLICY LIMIT 5 1000000 EMPLOYERS' LIABILITY DISEASE —EACH EMPLOYEE $ 10 00000 OTHER DESCRIPTION OF OPERATIONS /LOCATIONS /VEHICLES /SPECIAL ITEMS RE: BATH & BODY WORKS, SOUTHCENTER MALL 6p.,Q,.,sp 't1 ? C ENTER MALL j ' . .S ,WA 98188 CERTIFICATE HOLDER JUN 1,) t 996t l .. i 1, CITY OF TUKWILA i;':.�I?;;i? ;IVt; ; ;.`;? Building Department ) v:LcIpl i 6300 Southtenter Boulevard Tukwila, WA 98188 ACORD 26•S (7190) CANCELLATION *10 days far non-payment of Y. premi . SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING COMPANY WILL Ulann MAIL _ DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, KIXK MIDUREX1 1 00 0X0(X 9UICN) Qt1OQX7EXS( -1(1I(D( NI306IEXXX6100X600JKXXMR 14APOWX ICRAKVOMXJRlCD(REl6(I MPANURRMIRIX136460006R TOf(6* AUTHORIZED REPRESENTATIVE J. F. ARENTS AND COMPANY /a - : ` : © ACORD CORPORATION 1990 JUN-24-1996 14:59 P. 01 TOTAL P.01 ; 14 SPECIFICATIONS / NOTES DIVISION 1 GENERAL. REQUIREMENTS A. CONSTRUCTION DOCUMENTS T 1, DRAWINGS 4ND SP ARE 10184000 B0 COMPUNLNIARY. SPECIFIC INFORNRTON NAY 40 F0100 IN FIM6 OR 901 14. 2. THE TERM 'OWNER' AS STATED IN 114E FOLLOWING SPE0FCATIONS AND CONSTRUCTOR DOCUMENTS, REFERS TO THE TENANT OF 100 SPACE ONLY AND DOES NOT REFER TO THE LANDLORD OF THE PREMISES 3. ANY 'DISCREPANCIES. ERRORS OR OM00100S DISCOVERED IN THE CONTRACT DOCUMENTS BY THE CONTACTOR SNAIL BE BROUGHT TO THE 011901ON OF OWNER BEFORE P400000010 04111 RNA1E0 5ORK: OTHERWISE THE CORRECTION OF SUCH' IS THE RESPONMRLIIY OF THE CONTRACTOR 4. APPROVED VARIANCE 10 THE PLANS AND SPECIFICATIONS ON ONE PROJECT SHALL NOT 001STI1010 AN APPROVAL.: OF LIKE VARIANCES ON SUEMEQ09T PROJECTS. B. OWNER 0100000ES 1. 111E CONTRACTOR SHALL FURNISH FULL TIME CONTINUOUS SUPERVISION. THE PROJECT: SUPERINTENDENT SHALL REMAIN ON 0ITE THROUGH THE MERCHANDISE DATE OR THE COMPLETION OF THE PUNCHUST WHICHEVER IS LAST TO OCCUR. • 2. SUSPENSION OF ALL CEIUNG AND OVERHEAD FRAMING IS TO BE FROM STRUCTURAL MALL BEMIS AND 10P CHORDS OF TRUSSES ONLY. NOT FROM 3. GENERAL:. CONTRACTOR MAY SUBSTRU10 METAL FRAMING MEMBERS SHOWN ON DRAWINLS,WIM ALTERNATE CODE APPROVED FRAMING METHODS AND GAUGE SIZES WITH APPROVAL' OF OWNER'S CONSTRUCTOR MANAGER. 4. GENERA CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF IN -WALL BUDGETING FOR ALL ITEMS. IN STORE. REVIEW DRAWINGS THOROUGHLY. 5. ALL OWNER - FURNISHED MATERIALS ARE FURNISHED TAILGATE DELIVERY ONLY. THE CONTRACTOR 15 RESPONSIBLE TO UNLOAD, DEMURE, AND TRANSPORT MAMMALS FROM THE POINT' OF OFF -LOAD TO THE JOBS014 OR STORAGE AREA AS APPLICABLE. MATERIALS WILL BE DELIVERED TO THE CLOSEST AVAILABLE TRUCK DOCK OR OTHER 14001100 AS DIRECTED BY THE LANDLORD. 6. THE' CONTRACTOR TS RESPONSIBLE FOR DAMAGE. LOSS. THEFT, OR DESTRUCTION OF ALL OWNER - FURNISHED MATERIALS. THE CONTRACTOR WILL BE BACK - CHARGED.' THE FULL COST OF REPLACEMENT MATERIALS INCLUDING FREIGHT CHARGES..: 7. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF EACH TRADE WITH OTHER TRADES, CONTRACTORS SHALL NOT BE ENTITLED TO 400100N& COMPENSATION FOR WNFLCI5 WHICH RESULT FROM LACK OF COORDINATION OF THE INVOLVED TRADES . B. THE GENERAL CONTRACTOR SHALL EMPLOY SUBCONTRACTORS. WHO ARE EXPERIENCED AND WHO EMPLOY EXPERIENCED TRADESMEN. 9. THE GENERAL CONTRACTOR SHALL. NOT EMPLOY NOISY CONSTRUCTION TECHNIQUES OR EQUIPMENT DURING MALL OR STORE HOURS. • 10. THE CONTRACTORS SHALL WORK IN COOPERATION AND HARMONY 14711 THE LANDLORD AND THE ADJACENT TENNIS IN SCHEDU0NG WORK R ORDER TO SE IS 014901RED INCONVENIENCE WOKING IN AORTIC D TENAANTS SPACE, THIS COST WILL BE THE SOLE RESPONSIBILITY OF THE CONDUCTOR. 11. ME CONTRACTOR MOLL NOT U4102E GAS - OPERATE EQUIPMENT IN OCCUPIED SHOPPING CENTERS. THE CONTACTOR SHALL WORK IN HARMONY' WITH THE LANDLORD'S REQUIREMET5 RELATING 10 NOISE ABATEMENT AND SAFETY. 12 THE CONTRACTOR SHALL FURNISH' DUMP5TER5 AS REWIRED FOR TIE .EXCLUSIVE USE BY STORE PERSONNEL WRING MERCHANDISING. THE CONTRACTOR SHALL INCLUDE W THE BID A MNIMUM OF ONE 40 -1ARD DUM414104 OR THE EQUIVALENT. IF THE SALES AREA EXCEEDS 8,000 SQUARE FEET, THE CONTRACTOR SHALL 00720E ONE AD010NAL DUMPSTER. • 13 GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR THE COST OF ANY MID ALL v u OFF 511E STORAGE OF OWNER SU P ED ARTERIALS C DEMOUNO0 AND SPACE PREPARATION 1. WITHIN FIVE (5) GAYS OF COMMENCEMENT OF CONSTRUCTION, OR WITHIN TWO (2) DAYS FOLLOWING COMPLETION OF DEMOIJTON, THE CONTRACTOR SHALL CAREFULLY EXAMINE THE 511E MID REPORT TO THE OWNER'S CONSTRUCTOR MANAGER. ANY DISCREPANCIES 1N THE LEASE -HOLD DIMENSIONS OR 000100T5 BETWEEN' THE PHYSICAL ' SPACE AND THE INTENT OF THE WORKING DRAWINGS. HEICNIS. (04. D AVAILABLE HEIGHT FOORRROLL- -U POP-UP COUTO GRILLES). CDUNG 2. GENERAL. CONTRACTOR 15 TO CONTACT LANDLORD'S 01.1-51(8 MANAGE PRIOR TO ANY DEMOLITION WORK TO DETERMINE 004UBI7TY OF DUMP5IER PLACEMENT, NOISE AND DUST ABATEMENT REQUIREMENTS, ETC. 3. GENERA.. CONTRACTOR IS TO ARRANGE WITH THE LANDLORD A CONVENIENT TIME TO PERFORM 00000500 WORK AND INSTALL TEMPORARY PROTECTED MEANS OF EGRESS FROM REWIRE EIS. INCLUDING TEMPORARY LIGHTING AND SAFETY DEVICES, ALL IN ACCORDANCE WITH GOVERNING STATE AND LOCAL CODE AND LANDLORD REQUIREMENTS. 4. GENERAL CONTRACTOR TO ERECT BARRICADE AT STOREFRONT PER LANDLORDS SPECIFICATIONS. GENERAL CONTACTOR TO INSTAL DOVER- SUPPLIED BARRICADE SON OF PROVIDE) AS SHOWN ON INSTRUCTIONS SENT WITH BID PACKAGES. 5. THE GENERAL CONTRACTOR SHALL REMOVE. REPAIR, R61ORE' AND REPLACE WHERE NECESSARY OR INDICATED ON THE DRAWINGS OR AS REQUIRE. CUT ALL NECESSARY OPENINGS FOR ANY REWIRE PURPOSE AND REPAIR, WHERE NECESSARY,' AFTER CUING.. INSOFAR. AS POSSIBLE, ALL PROTRUSIONS. MARKS; CRACKS OR OTHER EVIDENCE OF A DEFICIENT OR DAMAGED CONDRON SHALL BE RUMINATE UNLESS SPECIFICALLY NOTE OTHERWISE, ANY PARTS WHICH ARE SPLIT, CRACKED. CHIPPED, WALE. BROKEN, MISSING, OR OUT OF LINE OR ADJUSTMENT, MECHANICALLY OR STRUCTURALLY UNSAFE OR UNSOUND;'. BOO. TORN, OR OTHERWISE DEFICIENT OR INJURE IN ANY MANNER, SHALL BE REMOVED, REPLACE, RESTORED, OR SATISFACTORILY REPAIRED AS DIRECTED BY THE OWNER'S CONSTRUCTION MANAGER. 6. GENERA CONDUCTOR: 15 RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL LEASE -HOLD IMPROVEMENTS INCLUDING, BUT NOT UNITED TO: INTERIOR WNL5, CEILINGS, FLOOR COVERINGS (ALL ADHESIVES), PLATFORMS, STORE- FRONTS, .ETC., (UNLESS INDICATE ORERMSE ON ARCHITECTURAL DRAWINGS). ALL EXISTING UNUSED MECHANICAL, ELECTRICAL AND /OR PLUMBING FIXTURES AND EQUIPMENT, INCLUDING ABANDONED ROOFTOP HVAC EQUIPMENT AND CURBS (UNLESS INDICATE ORERMSE ON MECHANICAL AND ELECTRICAL DRAWINGS) AND /0R SKYLGHTS' ARE TO BE REMOVED AND THE ROOF PATCHED PER REM 012 BELOW: CAPPING IS DDT PERMITTED I 7. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL. AND DISPOSAL OF ALL LOOSE ITEMS SUCH AS. BIT NOT UNITED TO: TRADE FIXTURES, MISCELLANEOUS DECORATORS. KITCHEN EQUIPMENT, ETC. B. AL ABANDONED ELECIRICAL/IFIEPHONE CONDUIT, PLUMBING 0NES AND MECHANICAL DUCTWORK MUST BE 8090510. DO THE POINT OF ORIGIN, 9. INFORM THE LANDLORD'S ON -SEE MANAGER OF ANY TUT NEEDING TO BE DISCONNECTED OR CAPPED, PRIOR TO DOING SO. 10. GENERA CONTRACTOR 15 TO EXERCISE EXTREME CARE DURING DEMOLISON SO AS NOT TO DAMAGE OR DISRUPT MIMES OR SPRINKLER LINES WHICH MIGHT PASS THROUGH 71115 SPACE TO SERVICE OTHER MALL SPACES OR OTHER TENANTS. (C.C. WILL BEAR SOLE RESPON51BIL11Y FOR ANY SUCH DAMAGE OR DISRUPTOR). 11. REMOVE ALL 60517151 FLOOR FINISHES AND PREPARE CONCRETE SUB FOR NEW FLOOR FINISHES. PATCH.' REPAR AND LEVEL COSTING SLAB. INFORM OWNER OF ANY IRREGULARITIES IN EXISTING SLAB IMMEDIATELY. 12. GENERA CONTRACTOR IS RESPONSIBLE TO PATCH AND /OR REPAIR EXISTING FLOOR SLAB. DEMISING WALL AND ROOF DECK AF100 COMPLETION OF DEMO LITTON AND PRIOR TO COMMENCEMENT OF NEW CONSTRUCTOR (G.C. MUST CONTACT LANDLORD PRIOR TO ANY ROOF YORK AND COORDINATE ACCORD- INGLY). 13, GENERAL. CONTRACTOR 15 RESPONSIBLE TO PATCH AND/ OR REPAIR EXISTING LANDLORD SOFFIT, FASCIA MO NEUTRAL PIERS TO LIKE NEW CONDITION PRIOR TO COMPLETION OF NEW STORE CONSTRUCTION. 14. GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION WORK MID MUST INFORM OWNER'S CONSTRUCTOR MANAGER OF THE EXTENT OF SUCH WORK. PRIOR TO BIDDING. 15. GENERAL CONTRACTOR IS TO 0440900E HIS RESPONSIBIUN FOR THE FLOOR SUB AND DEMISING WALL INSTALLATION OR NOOIRCATIONS WITH LANDLORD AND OWNER'S CONSTRUCTION MANAGER TO 9EE ALL TENANT IMPROVEMENT CRITERIA AND RESPONSIBIUtt SET BY THE LANDLORD OR OWNER. GENERAL CONTRACTOR IS 10 VERIFY THE ACTUAL CONDITION OF THE PERIMETER DEMISING WALLS AND /OR FLOOR SLAB PRIOR TO BIDDING. BID IS TO INCLUDE ALL WORK REWIRED. 1g Y LEGNCOMPLFTON OF nFM01 TON ANT PROD TO STARING OF S,,(NSRIIC,TON .TOR SUPERVISOR T VERIFY AND MATE OWNER'S ANA06• a (FACE /GYPSUM 8004D ON DEMISING WALL TO FACE/ GYPSUM BOARD IT. OVERALL LENGTH (LEASE UNE TO INNER -FACE OF GYPSUM BOARD ON REAR WALL.) a. ANY AND ALL COLUMN LOCATIONS - FREE STANDING OR PROJECTING. d. AVAILABLE CLEAR HEIGHT FOR GRILLE AND CDUNG AS DIMENSIONED ON DRAWINGS. D. LAYOUT OF WORK 1. EXERCISE PROPER PRECAUTION TO VERIFY ALL EXISTING 005000NS AND LAYOUT OF WORK. CONTRACTOR TO NOTIFY OWNER'S CONSTRUCTION MANAGER OF ANY DISCREPANCIES 1MMEDRTELY. CONTRACTOR IS RESPONSIBLE FOR ANY ERROR RESULTING 8041 FAILURE TO EXERCISE SUCH PRECAUTION. SUCH ERROR WILL NOT BE CONSIDERED SUBSEQUENTLY AS A BASIS FOR EXTRA COMPENSATION. 2. SHOULD A CONTRACTOR FIND DISCREPANCIES IN, OR OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS. OR SHOULD HE BE IN DOUBT AS TO THEM MEANING, HE SHALL AT ONCE NOTIFY THE OWNER'S CONSTRUCTION MANAGER. 3. GENERAL CONTRACTOR I5 RESPONSIBLE FOR SUPPLYING OR RENTING ALL TOOL, WELDERS, GENERATORS, ETC. FOR COMPLETING PROJECT. E. CODES AND STANDARDS 1. AL WORK, MATERIALS A110 INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH A11. ORDINANCES. STATE AND LOCAL BUILDING CODES, LATEST EDMON, AND FOLLOW APPLICABLE LANDLORD REQUIREMENTS. 2. DESIGN LOADS: LOADS AND CODE RESTRICTIONS FOR ALL DESIGN CONSIDERATIONS SHALL CONFORM TO THE LOCH. AND STATE CODES. AND ALL GOVERNING CODES. F. GENERAL CONDM0N5 1. THE AMERICAN INSTITUTE OF ARCHITECTS DOCUMENT A201 'GENERAL CONDITIONS OF THE CONTRACTOR FOR CONSTRUCTION 15 A PART OF THE CONDUCT DOCUMENTS. DIVISION II SITE WORK A NO WORK UNDER THIS SECTION, UNLESS NOTED OTHERWISE ON CONSTRUCTOR DRAWINGS. DIVISION III CONCRETE A THE CONDUCTOR 15 REPONSIBLE 10 DETERMINE IF A NEW CONCRETE SLAB IS REQUIRED IN ALL OR PART OF THE LEASED SPACE SUCH FLOOR SLAB SHALL BE INSTALLED IN ACCORDANCE WITH ALL REQUIREMENTS. LOCAL CODES, OR COMMON STANDARDS OF PRACTICE TO THE LOCALLY OF THE PROJECT OR WHICHEVER IS STRICTER. IN THE ABSENCE OF THE ABOVE, THE CONTRACTOR SHALL CONTACT ME OWNER FOR DIRECTION. MINIMUM REQUIREMENTS FOR TH4 FLOOR SLABS ON GRADE SHALL BE FOUR INCH THICK CONCRETE SLAB REIN- FORCED WITH Co 7 4.W.F.: CONCRETE TO BE 3,500 P5: OR HIGHER PLACED OVER SIX MILL VAPOR BARRIER OVER COMPACTED SKID /AGGREGRAIE BASE. ME SOIL SHALL BE INSECT TREATED IF CUSTOMARY TO THE LOCALITY OR AS RE- QUIRED BY LANDLORD. B. FOR SPECIFICATIONS OF RASED PLATFORMS IN STORE (IF APPLICABLE).. REFER TO DETAIL OF THIS SET. DIVISION IV MASONRY A THE CONTRACTOR SHALL ACCOMPLISH ANY MISCELLANEOUS MASONRY WORK ON THE P5 YET INCIDENTAL TO 711E ACCOMPLISHMENT THE MANS. OR NOT INDICATED VJN THE L MATCH OF OTHER WORK. WHERE APPLICABLE, MASONRY WORK SHALL MATCH EXISTING WORK. FINISH BRICK WORK SHALL BE NEATLY TOOTED INTO EXISTING MASONRY IF APPLICABLE. DIVISION V MISCELLANEOUS METALS A. STRUCTURAL STEEL: REFER TO STRUCTURAL DRAWINGS OF APPLICABLE). B. METAL STUDS: GALVANIZED STEEL STUDS SIZED AS INDICATED ON DRAWINGS OR AS 4E000E0. INCLUDE Al ACCESSORIES. SUCH AS BRIDGING, RACK, ETC. PROVIDE ALL MISCELLANEOUS BOLTS, CUPS, ANCHORS, ANGLES, BRACKETS. SLEEVES, FASTENERS, AND OTHER METAL ITEMS AS REQUIRED. WOOD STUDS MAY BE SUBSTITUTED WHERE PERMISSIBLE BY CODES. C. DECORATIVE METAL: INSTALL OWNER - PROVIDED DECORATIVE METAL SUCH AS STAINLESS STEEL PREFlNISHED METAL, ETC. AS INDICATED ON DRAWINGS. PER MANUFACTURER'S RECOMMENDATONS. DIVISION VI CARPENTRY A PROVIDE NEW LUMBER, BEARING GRADE AND TRADEMARK OF ASSOCIATON UNDER WHICH D WAS PRODUCED. B. LAYOUT, CUT, FR AND ERECT FRAMING FOR ROUGH AND FINISHED WORK. INSTAL BLOCKING. HAILERS. FURRING AND OTHER ROUGH AND FINISHED MATERIALS AS REQUIRED. BRACE, PLUMB AND LEVEL MEMBERS IN RUE ALIGNMENT AND RIGIDLY SECURE IN PLACE WITH SUFFICIENT NAILS, SCREWS AND BOLTS AS NECESSARY. C. 058 NON - COMBUSTIBLE /FIRE RETARDANT LUMBER AND RIM WHERE REQUIRED BY STATE OR LOCAL CODES. WHICH BEAR THE MANUFACTURER'S STAMP OF AUTHENTICITY. D. FURNISH AND INSTALL ALL GROUNDS OR BLOCKING REQUIRED TO RECEIVE STORE FIXTURES. E. FURNISH AND INSTALL ALL ROUGH HARDWARE, ANCHORS. BOLTS, ETC.. AS REQUIRE FOR CARPENTRY WORK. F. MILLWORK 1. RECEIVE AND INSTALL ALL FINISHED MILLWORK. CABINET WORK, PANELING. DOORS. FRAMES. ETC., AS SHOWN ON DRAWINGS OR AS DIRECTED. 2. CUT AND FT ALL MILLWORK AND SET PLUMB AND TRUE. 3. COPE ALL IN- CORNERS, MITER ALL OUTSIDE CORNERS. 4. SAND ALL SURFACES TO SMOOTH AND EVEN FINISH. 5. BACK OUT FLAT RIM TO PREVENT WARPING. DRILL WHERE NECESSARY TO PREVENT SPLITTING. 6. FIT ALL DOORS TO LEAVE EQUAL SPACES ON ALL SIDES. 7. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROTECT ALL FINISHED MILLWORK WITH 0SQUEEN, CARDBOARD. ETC. DIVISION VII THERMAL AND MOISTURE PROTECTION A. ROOFING /FLASHING 1. GENERAL CONTRACTOR TO CONTACT LANDLORD'S ON -511E MANAGER FOR SPECIFICATIONS ON ROOF PATCHING OR NAME OF ROOFING CONTRACTOR TO CONTACT FOR REPAIRS. B. INSULATION 1. GENERAL CONTRACTOR TO PROVIDE AND INSTALL RIGID MD /OR FULL BAT INSULATION AND VAPOR BARRIER AT WALLS AND CEILING AS REQUIRED BY LANDLORD AND CONSTRUCTION DRAWINGS, C. SKYLIGHTS (NOT APPLICABLE) DIVISION VIII DOORS AND WINDOWS A DOORS AND HARDWARE 1. DOOR HARDWARE: REFER TO 000R SCHEDULE FOR HARDWARE SPECIFICATIONS. 2. HOLLOW METAL FRAMES: 0.0. MINIMUM 16 GAUGE. SIZE AND SHAPE PER DOOR SCHEDULE, 3. LABELED DOORS: WHERE REQUIRED. PROVIDE U.L. LIBEL 000R5 AND FRAMES PER WPUCABLE STATE AND LOCAL BUILDING CODES. LABEL DOORS TO RECEIVE DOOR CLOSER. 4. FABRICATE AND ERECT TRUE, PLUMB AND SQUARE AS SPECIFIED AND AS DETAILED AND PER MANUFACTURER'S RECOMMENDATONS. B. ROLLING GRILLE 1. ROLLING GRILLE PROVIDED AND INSTALLED BY OWNER. 2. CAREFULLY COORDINATE INSTALLA0ON AND HOOK -UP OF ROLLING GRILLE 0TH ALL AFFECTED TRADES. REFER TO DOOR SCHEDULE. 3. INSTALLATION BRACKET AT GRILLE SUPPORT POST BASE MUST FACE MALL CORRIDOR SIDE. C. GLASS AND GLAZING 1. GLASS a. STOREFRONT GLASS TO BE HORIZONTALLY TEMPERED. SEE AND NUMBER. OF PIECES AS 5110044 ON DRAWINGS. GLAZING. CONTRACTOR. TO PROVIDE AND INSTALL' - AL GLAZING CHANNEL, GASKETS, BLOCKING, ETC.. REWIRED. TOR COIBLETE INSTNURON PROVIDE NEAT. UNIFORM (1 /4 WIDE UNLESS NOTED OTHERWISE) GAPS BEWEEI4 GLASS PRIES AND BETWEEN PANE' AND ADJACENT VERTICAL SURFACES b, /MISSED EDGE: EDGES TO BE DIAMOND GROUND 1/16 45 DEGREE BEVEL AT FROM' AND BACK FACES 0.1111 ALL EXPOSED EDGES UNIFORMLY MACHINE POUSHED. c. OWNER REQUIRES THAT STOREFRONT GLASS NOT BOW MORE THAN +/- 1/17 OUT OF VERTICAL. U. ALL GLASS TO BE SET ' IN GLAZING GASKET THE 51ZE AND SHAPE NECES- SARY TO ACCOMPUSH. GOOD WORKMANSHIP. CAULKING NOT PERMITTED. e. GLAZING CUPS ARE NOT TO BE USE UNLESS REQUIRED : BY LANDLORD' OR CODE. IF REQUIRE. GENERAL CONDUCTOR SHALL' USE BLACK. ROUND CLIPS MANUFACTURED BY LAMBERT SHEET METAL 3770 EAST.. FIFTH : AVENUE, COLUMBUS, OHIO (614) 237 -0384. 2. MIRRORS a. MIRRORS: NOTED (01-1) TO BE 1/4' CLEAR PLATE PROVIDED ARD INSTALLED BY CONTRACTOR WITH CONTINUOUS BRIGHT, SHINY ALUMINUM L S J-CHANNEL TOP AND BOTTOM (800 -421 8144) SET IN M WHENCE CO ., b. INSTALL UOEST S12E POSSIBLE TO ACHIEVE THE LEAST NUMBER OF VERTICAL JOINS. 008150513. JOINS ARE NOT ACCEPTABLE, EXCEPT WHERE INDICATED OTHERWISE ON DRAWINGS. C. ALL EDGES OF MIRRORS TO BE FIAT GROUND AND P0U5HED TO CREATE A SMOOTH FINISH. NO ROUGH EDGES ON MIRRORS WILL BE PERMITTED, ENTRANCE AND STOREFRONT 1. INSTALL STOREFRONT. AS SHOWN ON DRAWINGS, CAREFULLY COORDINATING ALL TRADES INVOLVED. DIVISION IX FINISHES A. GYPSUM DRYWALL 1. FURNISH AND INSTALL ALL GYPSUM DRYWALL 8410 SYSTEMS COMPLETE WTI PARTITION FRAMING, CEILING SUSPENSION SYSTEMS AND RELATE ACCESSORIES. PARTS, MATERIALS. ETC. AS SHOWN ON DRAWINGS AND AS SPECIFIED. INSTALL ALL MATERIALS PER MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATONS. 2. GYPSUM DRYWALL U.S. GYPSUM 5/7. THICK FIRE CODE SHEEROCK (TYPE 'X') PANEL OF 51ANDA8D QUALITY. GENERAL CONTRACTOR MAY USE NON- RATED 5/6 THICK BOARD IN AREAS OF STORE WHERE MOWED BY STATE AND LOCAL C006. ALWAYS USE TYPE 'X' ON DEMISING WAILS. 3. FASTENERS: ORYWAL SCREWS OF PROPER SIZE AND TYPE, PER MANUFAC- TURER'S RECOMMENDATIONS. 4. MET ACCESSORIES: ESSORIES: U.S. GYPSUM OR GOLD BOND 5141:[0 OF' COMPONENTS C PAID JOLT TAPE 5. JOINT TREATMENT: U.S. GYPSUM OR GOLD BOND SYSTEM OF COMPONENTS AND JOINT TAPE. B. CEIUNG SYSTEMS 1. FURNISH AND INSTALL CEILING SYSTEM COMPLETE MR SUSPENSION Sn: W AND RELATED ACCESSORIES AS SHOWN ON DRAWINGS AND AS SPECIFIED. 2. SUSPENSION SYSTEMS SHALL BE ADEQUATE TO SUPPORT LIGHT FIXTURES.. CEIUNG, GRILLES. DIFFUSERS AND OTHER NORMAL ACCESSORIES. PRODUDE. SYSTEM COMPONENTS FROM A SINGLE MANUFACTURER. 3. INSTALL CEIUNG AND SUSPENSION SYSTEMS IN STRICT ACCORA 00 041 1 MANUFACTURER'S RECOMMENDATIONS. FINISH CEIUNG SHALL BE LEVEL. 0NT1 JOINTS SNUG AND SQUARE, AND TILES OR PANEL IN PERFECT CONORON.. 4 INSTILL SECURITY GRID CUPS ON FIRST TWO TILES AT UY -15 CBUNOS AROUND PERIMETER OF STORE (IF CODE OR LANDLORD REQUIREMENTS PROHIBD GYPSUM BOARD ON DEMISING WALLS TO RUN FULL HEIGHT TO DECK). 5. MATERIALS ARD FINISHES 8. REFER TO DRAWINGS FOR LOCATION OF SPECIFIED MATERIAL AND FINISH6. b. SAI.E5 AREA CEILING: (IF SHOWN ON RELECTED CEILING PLAN), ARMSTRONG CIRRUS SCORED BALED TEGULN 2' x 2' DESIGN /590 WHITE META_ GRID TO BE ARMSTRONG 50PRAF1NE AIL EXPOSED TEE Sn:18, PREFlNISHED TO MATCH TILE. c. 505 -5ALES CEILING: ARMSTRONG 2' X 4' NON - DIRECTIONAL FISSURED OR EQUAL TILE AND GRID TO BE WHITE, CLASS 'A' RATING. 3. WHEN A ONE -HOUR FRE -RATE CDUNG ASSEMBLY IS REQUIRED BY IAN/- LORD, STATE OR LOCAL CODES, THEN GENERA CONTRACTOR IS TO CONFORM WITH UNDERWRRER'S LABORATORIES DESIGN FOR A ONE -0008 RATED ASSEMBLY. USING THE CEIUNG CHOICE LISTED BELOW FIRE -RATED NON -SALES AREA CDUNG: ARMSTRONG N0. 898A GEORGIAN. 2' x 4' PANEL WITH WHITE FINISH: META GRID TO BE WHIR. e. C.C. IS TO PROVIDE ONE BOX OF THE SPECIFIED. CEUNG TIES ON S9E FOR FUTURE USE C. PAINTING, FINISHING AND WALL00004 NG 1. THE INTENT 15 TO PROVIDE A SATISFACTORY FINSH TO AL PATR5:OF THE PROJECT. WHETHER NOTED HEREIN OR NOT, UNLESS SPECIFICALLY STATE. OTHERWISE, COVER ALL SURFACES THOROUGHLY. IF THE NUMBER OF COATS SPECIFIED DOES NOT ACCOMP05H THE INTER, THE APPLY A :MORAL COATS OF SPECIFIED MATERIAL TO GIVE SATISFACTORY COVERAGE SEE RNISH SCHEDULE. 2. PANT CONTRACTOR 15 TO REVIEW ELEVATORS, FLOOR AND WALL FINISH PLANS, CONSTRUCTOR OETAL SHEETS, REFLECTED CEIUNG PLAN, AND PRESENTATION PLAN /DEAL FOR HELPFUL CURIFICATON OF ITEMS AND SURFACES TO BE PANTED. REQUEST SHEER FROM HOME OFFICE IF REQUIRE. 3. BEFORE STARTING FINISH WORK. REMOVE HARDWARE, ACCESSORIES, PLATES, 8GH01NG FIXTURES AND SIMILAR REM5. OR PROVIDE AMPLE PROTECTION FOR SUCH 0TD40. 4. USE ONLY 7110 PAINT AND RELATED MATERIALS OF THE MANUFACTURERS SPECIFIED. 5. CLEAN ALL SURFACES TO BE PANTED FREE OF LOOSE DIRT AND DUST BEFORE WORK 15 STARED. 6. PANTED DRYWALL TO RECEIVE ONE COAT OF LATEX PRIMER AND 191 COATS OF SPECIFIED PANT. TM PRM6 TO APPROXIMATE SHADE OF THE FINAL COAT. TOUCH UP ALL SUCTION SPOTS OR HOT SPOTS AFTER APPLCATON OF FIRST COAT AND BEFORE APPLYING SECOND COAT, TO PRODUCE AN EVEN RESULT IN THE FINISH COAT. DRY ALL COATS THOROUGHLY BEFORE APPLYING SUC- CEEDING COATS. FOLLOW MANUFACTURER'S 4S0010ENDA110NS FOR RECOAT TIME. SEAL ALL DRYWALL SURFACES BEHIND MIRRORS. 7. STAINLESS STEEL, ALUMINUM, CHROME -PLATE SURFACES AND ALL OTHER BRIGHT 1.10A FINISHES SHALL NOT BE PANTED UNLESS DIRECTED OTHERWISE 8. WASH ALL METAL SURFACES WITH MINERAL SPIRITS TO REMOVE ALL DIRE AND GREASE BEFORE APPLYING FINISH. WHERE RUST AND/OR SCALE IS PRESENT, WIRE BRUSH OR SAND CLEAN BEFORE APPLYING FINISH. 9. ALL METAL SURFACES PAINTED BY PANT CONTRACTOR ARE TO BE PRIME WITH A HIGH QUALITY METAL PRIMER (UNLESS NOTE OTHERWISE). FINISH COATS MUST NOT REVEAL BRUSH MARKS. SPRAY OR APPLY AS NEEDED, 10. PUTTY ALL NAL H01E5. COUNTERSINK SCREWS, BOLTS, CRACKS. ETC. BEFORE APPLYING FINISH. 11. SAND ALL WOOD SURFACES TO BE PANTED SMOOTH AND EVEN BEFORE APPLY- ING FINISH. 12. GENERA CONTRACTOR TO APPLY ALL TAMS PER MANUFACTURERS SPECIFICA- TIONS. APPLY STAN TO CLEAN /DRY SURFACES ONLY. 13. PANT ALL ACCESS DOORS, FIRE EXTINGUISHER CABINETS. EQUIPIENT MOUNTING BOARDS, ETC. I5 /01 GYP. BOARD WALLS MID/OR CEILINGS. PAM TO MATCH AAMSET WORK UNLESS OTHERM514 NOTE OR DIRECTED. 44. SAND ENAMELED FINISHES APPLIED TO WOOD OR METAL BETWEEN COATS WITH FINE SANDPAPER TO PRODUCE SMOOTH. EVEN FINISH. i 111 11111 " IPTl11i1j1p1TNI IITNIN IT1P) T 'I'N11i11 IAN F 15. MALE. FINISH WORK UNIFORM OR APPROVED FINISH: 5000TH. FREE OF RUNS. SAGS. DEFECTIVE BRUSHING AND CLOGGING. MME EDGES OF PAINT.ADIOIN- ING OTHER MATERIALS OR COLORS SHARP AND CLEW WITHOUT OVERIFPPING. 16. FELD PANTING, EXCEPT TOUCH -UP. WILL NOT BE REQUIRED ON ITEMS SPECIFIED TO BE COMPLETELY FINISHED AT FACTORY (PRE - FINISHED). UNLESS SPECIFICALLY DESIGNATED.:: 17. WALT. COVERINGS. REEK,10 5N1SH 9CHEDULE AND FINISHES AS 50180 ON DRAWINGS FOR LOCATION AND EXTENT. a. INSTALL ALL MATERIALS EN SKILLED WORKMEN, IN STRICT ACCORDANCE WITH MAIUFATUR1S: IN5RUC10415 b SEAL DRYWALL BEFORE APPLICATION OF WALL COVERING WITH LATEX PRUNER. FINI5HT0 BE SMOOTH. c. ADHESIVES USED IN THE APPLICATION OF WALL COVERINGS TO BE PRE - 01800 AS RECOMMENDED BY MANUFACTURER FOR THE SURFACE INVOLVED. d,' NAVE FINISHED INSTALLATION FREE. OF BUSBOYS, WRINKLE OR OTHER DEFECTS. HAVE AL SEMIS TIGHTLY CLOSED. HATCH ADJACENT STRIPS AS REQUIRED CONSISTENT. WITH PATTERN SELECTED. AVOID CORNER SEMIS WREN POSSIBLE e. IF CLEANING 15 REQUIRED, USE ONLY MATERIALS AND METHOD RECOMMEN- DED BY MANUFACTURER OF WALLC0410050 USE. T. CONTRACTOR 15 RESPONSIBLE FOR UNROLLING AND CHECKING FABRIC FOR DEFECTS IMMEDIATELY UPON DELIVERY. DO NOT HANG DEFECTIVE FABRIC. 0. FLOOR PREPARATION FOR FINISH FLOORING 1. THE GENERAL CONTRACTOR SHALL EXAMINE EXISTING SLAB CONDITIONS TO DETERMINE TO WHAT EXTENT FLOOR PREPARATION. LEVE0NG, CHIP HAMMERING. ETC.. WILL -. BE RECTUM' TO FURNISH A SMOOTH, LEVEL SUBSTRATE FOR THE PROPER INSTALLATION. OF ALL FLOORING MATERIALS. PIE COST OF SUCH WORK TO THE EXTENT THAT T CAN BE DETERMINED' DURING THE BID PROCESS SHALL BE THE RESPONSIBILITY OF ME CONDUCTOR. UNEVEN SUBSTRATE. WILL NOT BE ACCEPTED AS AN EXCUSE FOR POORLY INSTALLED FLOORING CONTROL. AND EXPANSION JOINTS FOR 4105H FLOORING 1. THE CONTRACTOR 15 RESPONSIBLE TO EXAMINE THE SUBSTRATE AND INSTALL CONTROL OR 605510ON JOINTS AS REQUIRED DUE TO EXISMNG CONDITIONS WHEN CONTROL JOINIS/EXPANSION JOINS ARE REQUIRED, THE CONTRACTOR IS TO 0001301 1140 OWNER'S CONSTRUCTION MANAGER FOR APPROVAL OF METHODS OR SYSTEMS PRIOR TO INSTALLATION. • F. CERAMIC TILE 1. CERAMIC TILE AS SPECIFIED IN FINISH SCHEDULE AND RESPONSIBILITY SCHEDULE. (IF APPLICABLE). 2. INSTAL. CERAMIC TILL USING RECOMMENDS METHODS OF THE TILE CONTRACTORS ASSOCIATION OF AMERICA MID TIE TTEE COUNCIL OF AMERICA INC. - 3. INSTALL CERAMIC TT USING GROUT AND JOINT SPACING SPECIFIED IN FINISH SCHEDULE. 4. ADHESIVE IS TO BE PROVIDED AND INSTALLED 9Y GENERAL CONTRACTOR (PER MANUFACTURER'S SPECIFICATIONS)., 5. CAREFULLY: CL5,W ALL WORK AND REPLACE OR REPORT ANY DAMAGE WORK AND LEAVE IN PERFECT CONDITION. USE NO ACID, AGENT. OR DEVICE THAT WILL MAR . SURFACE. CONSULT WITH OWNER'S CON5IRINTON MANAGER FOR INSTRUCTORS.: (D0 NOT PO0SH CERAMIC TILE))." BE SET WITHOUT RIPPING HAZARD TO CUSTOMS OR STAFF. 7. THE GENERAL CONTACTOR IS RESPONSIBLE: TO CORRECT RASED CERAMIC TILES FOR THE ENTIRE DURATION OF THE WARRANT PERIOD AT THE DIRECTION OF THE OWNER'S CONSTRUCTION MANAGER. 0. CARPET (NOT APPLICABLE) • H. VINYL RESIUENT TILE (NON 1. 1/6 X /2 X 17 VINYL RE1UENT TILES WITH 4" HIGH X 1/6 THICK TOP- SET COVED TAUPE VINYL BASE, 5E FINISH SCHEDULE : BUR BASE TO FLOOR AND WALL' WITH NO GAPS. 2. FILL ' ALL CRACKS. JOIMS ETC. IN SUB-FLOOR MOT CRACK FILLER APPROVED BY FLOORING MANUFACTURER. INSTALL IN_ MATERIAL WITH WATERPROOF TYPE ADH67155 AS RECOMMENDED BY FLOORING MANUFACTURER FOR MA- TERIALS AND SURFACES INVOLVED. J. WOOD FLOORING 1. INSTALL AS SPE51F1400 FINISH SCHEDULE. ANO RESPONSIBILIY SCHEDULE. 2. PATCH TOP OF SLAB TO OBTAIN A SMOOTH. FLUSH SURFACE. 3. IT I5 CRITICAL THAT THE 4050 FLOOR BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S DIRECTION5. SHIPPED WITH THE MATERIAL. 4. WOOD FLOORING - ADHESIVE AND CLEANER I5 PROVIDED MD INSTALLED BY GENERAL CONTRACTOR. (PER MANUFACTURER'S SPECIFICATIONS). 5. INSTALL WOOD FLOORING WITH ALL SEAMS FLUSH AND DORT, WITH 110 GAPS. (CUT TO FD AS REQUIRE). 6, W000 FLOORINGS SHALL BE PROTECTED AT ALL TIMES WITH CARDBOARD, CRAFT PAPER. ETC. PROTECTION SHALL REMAIN IN PLACE UNTIL THE FINAL CLEANING PROCESS. DIVISION SPECIALTIES AND MISCELLANEOUS A. CABINET. WORK 1. PRE5NI5HE CABINETS ARE SUPPLIED BY OWNER AND SHIPPED TO JOB SITE UNASSEMBLED. GENERA CONTRACTOR IS TO ASSEMBLE ALL CABINETS REFER- RING TO CONSTRUCTION AND INSTALLATION DETAIL OF THIS SET. 2. GENERA CONTRACTOR SHALL BE RESPONSIBLE FOR UNLOADING, INSPECTING AND STORAGE OF CABINET COMPONENTS. GENERA CONTACTOR SHALL IMME- DIATELY INFORM OWNER OF AT DISCREPANCIES IN TYPE OR AMOUNT OF CABINET COMPONENTS OR ANY DAMAGE. 3. GENERA CONTRACTOR SHALL TAKE PRECAUTIONS DURING TERME TO ENSURE COMPONENTS ARE NOT DAMAGE 4. GENERA CONTRACTOR SHALL ASSEMBLE AND INSTAL. CABINETS IN LOCATORS SHOWN ON PLANS. a. GENERAL CONTACTOR SHALL TAKE PRECAUTIONS DURING INSTALLATION NOT TO DAMAGE PREFlNISHED COMPONENTS. b. GENERA CONTRACTOR TO FASTEN COMPONENTS TOGETHER PLACING FASTENERS AS INCONSPICUOUSLY A POSSIBLE. REFER TO INSTALATION DEAL OF THIS SET. c. GENERA CONTRACTOR IS TO NSW- ALL COMPONENTS WITH EXPERIENCED FINISH CARPENTERS ONLY TO ASSURE 000001' ASSEMBLY. B. ACCESS PANEL: AS MANUFACTURED BY J.L. INDUSTRIES. BLOOMINGTON, MN, (612) 635 -6850 OR OTHER WHICH MUST BE APPROVED BY OWNERS CONSTRUCTION MANAGER. SUBSUME MTH 'B LABEL FIRE PANEL, MODEL M. KEY LOCK, ONLY IF A RATE DOOR 15 REQUIRE. PER CODES C. ACCESS PANELS: AND REFLECTED CEIUNG P1A445. IN ABSENCE OF DEFINED 10000055. THE GENERA CONTRACTOR I5 TO FURNISH AND INSTALL ACCESS PANELS AS NEC- ESSARY TO FURNISH REASONABLE, SAFE ACCESS TO SERVICE ALL SERVICEABLE COMPONENTS OF EACH PIECE OF EQUIPMENT. ASSUMED ACCESS SHALL BE BY A. TECHNICIAN(S) STANDING FIRMLY ON A LADDER. WHERE ACCESS P3615 OR REMOVABLE DIFFUSERS CANNOT BE LOCATED IMMEDIATELY ADJACENT TO THE EQUIPMENT, THE CONTRACTOR I5. TO FURNISH EA 000- COMBUSTIBLE CATWALK OR ABOVE CDUNG SECURED PUNTING OR METAL DECKING OR 51NIUR NONCOM - eusne E MATERIAL TO PERMIT ACCESS TO THE EQUIPMENT FROM THE NEAREST ACCESS PANEL OR LIFT -OUT DIFFUSER. CATWALKS MUST BE OBSTACLE-FREE TO A HEIGHT OF 3 FOOT 0 INCHES ABOVE THE GATEAU. CATWALKS MUST BE CAPABLE OF SAFELY SUPPORTING A MINIMUM OF TWO (2) TECHNICIANS PLUS EQUIPMENT AND BE CONSTRUCTED OF NON - COMBUSTIBLE MATERIALS. D. THE GENERA CONTRACTOR I5 RESPONSIBLE TO ASSEMBLE ALL MISCELLANEOUS NON -SALES AREA WAIL STANDARDS, SHELVES, BRACKETS, ETC. E. LAVATORY FlXTURE5: LAVATORY ACCESSORIES: REFER TO DETAIL A/9.1 AND REPONSIBIUIY 5CHE1XE. F. G. _ _F I F THIS MICROFILMED DOCUMENT IS LESS RESTORE LANDLORD'S STRUCTURAL STEEL FIREPROOFING TO NNNIAIN INTEGRITY OF SAME AND FIREPROOF AS REQUIRED. CLEANING: THE CONTRACTOR SHALL TURN OVER TIE PROJECT IN A 51151, DU5T. FREE, DIRT FREE 5050(0ON. THE CONTRACTOR SHALL EMPLOY A PROFESSIONAL CLEANING SERVICE EMPL04NG ONLY TRAINED PER50NNEL. CLEANING SHALL INCLUDE. BUT NOT BE LIMITED TO THE FOLLOWING: 1. STOREFRONT GLASS (INSIDE AND OUR 2. MIRRORS 3. STOREFRONT. METAL 4. SONS 5, CABINETS. INCLUDING SHELVING. BASES, VALANCE, FILLERS. AND END PANEL 6. 4GHT FIXTURES INCLUDING CANS, TRIM, TRACK AND TRACK HEADS 7. FLOORING PER MANUFACTURER'S RECOMMENDATIONS) 6. VINYL VII FLOOR TILE CLEANED MID 047410 I 9. B TON TEMS, PROPS. AND TRADE )E FlXNRES WOOD 10. WOOD BASE 11. WALL COVERINGS 12. NON -SOLES SHELNNC, STORAGE PLATFORMS, RFC. UPON COMPLETION OF MERCHANDISING. GENERAL CONTRACTOR TO RE -CLEAN STORE TO DUST -FREE, DIRT -FREE CONORON. DIVISION 01 EQUIPMENT A NO WORK UNDER THIS SECTION, UNLESS NOTED OTHERWISE ON CONSTRUCTOR DRAWINGS. DIVISION -XII FURNISHINGS GENERAL CONDUCTOR 15 RESPONSIBLE FOR ASSEMBLY AND PLACEMENT OF OFFICE AND NON -SALES EQUIPMENT AND FURNITURE,. THE CONTRACTOR I5 RESPONSIBLE TO UNCRATE, ASSEMBLE, AND PLACE TRADE FIXTURES AND PRESENTATION DENS IN SALES AREA FIXTURES TO BE LOCATE PER THE DIRECTION OF THE OWNER. DIVISION 0111 SPECIAL CONSTRUCTION A NO WORK UNDER THIS SECTION, UNLESS NOTE OTHERWISE ON CON5150000N DRAWINGS. DIVISION XIV CONVEYING SYSTEMS A NO WORK UNDER THIS SECTION, UNLESS NOTED OTHERWISE ON CONSTRUCTION DRAWINGS. A SEE 011401127081 AND ELECTRICAL DRAWINGS FOR SPECIFICATIONS. DIVISION XV DIVISION XVI MECHANICAL ELECTRICAL 1f.Mo ret ire Rs Ivieck 4 Trew ik Wood rovire4 M0 16446 rwr V.4 C. (01. CONSTRUCTION TYPE. 2 N FILE COPY 1,aa *11141 ,a Plan Cb0CK0C4104515 are A41 d`nnraam � 014m 4TR go I p d rlc sA /// 71� / KEY PLAN BATH AND BODY WORKS SPACE NO. 844 THE SON B -2 USE GROUP' OCCUPANCY LOAD: SALES 69 NON.SALES 2 TOTAL 71 / STORE AREA • APPROX. GROSS AREA: APPROX. BBW SALES AREA: 2,593 SO. FT. 2,057 SO. FT. Bath & Body Works 97 WAN MAT. Street New Albany, Oh1P 4.1494 St 351 SOUTHCENTER MALL 633 SOUTHCENTER MALL SEATTLE, WASHINGTON 98188 TENANT BATH & BODY WORKS THREE LIMITED PARKWAY COLUMBUS, OHIO 43230 TENANT'S REPRESENTATIVES (614) 479- # SHIRLEY SCHMITTER DIRECTOR OF STORE PLANNING TONY OLIVER DESIGNER: it 7290 LYSA ERWAY PROJECT COORDINATOR: • 7321 eqb1Q ijIq TENANT'S CONSULTANTS RETAIL DESIGN GROUP, INC. H.B.K. CONSULTANTS GLEN HANSON SENIOR CONSTRUCTION MANAGER PETE HUTCHINS ENGINEER: W 7414 RON BASHOR CONSTRUCTION MANAGER: W 7338 HOLLY HUFF MATERIAL EXPEDITOR: 0 7247 DEVELOPER JACOBS BROTHERS CONSTR. CO. OF OHIO 25425 CENTER RIDGE ROAD CLEVELAND, OHIO, 44145 -4122 (216) 871-4800 DEVELOPERS TENANT COORDINATOR BILL ROWE JACOBS BROTHERS CONSTR. CO. OF OHIO 25425 CENTER RIDGE ROAD CLEVELAND, OHIO, 44145 -4122 (216) 892 -2388 / DRAWING INDEX ORIONAL DATE: 4-1880 TITLE AND SPECIFICATION SHEET M/ NOTES AND SCHEDULES MD /1 2.1 CONSTRUCTION AND FIXTURE PUN M 3.1 REFLECTED CEILING PUN CO/1 32 LIGHTING PLAN LM /2 41 FLOOR AND WALL HNISH PLAN LM /3 4.2 INTERIOR ELEVATIONS E/1 5.1 STOREFRONT DEAL F/2 5.2 STOREFRONT DEAL 5.3 STOREFRONT DEALS ED /1 6.1 DEAL OF L,N.N.P,R,S AR0 T CABINET ED / 02 DETAILS OF LLLN.P,R.S AND i CABINET 8 .74 7.1 DEALS OF WALL BERING BACIOVRAP E %2 7.2 DEMONSTRATION AREA DETAILS 7.3 BASKET AREA DEALS 8.1 MISCELLANEOUS DETAIL 8.2 MISCEILANEWS DEAL 9,1 NON -SALES DEAL 10.1 PRESENTATION PLAN 11.1 PRESENTATION DETAILS APR 2 91996 MECHANICAL PLAN MECHANCAL SCHEDULES k DETAILS uECHANCAL SPECIFICATIONS T U M +N� R RErCONROLS DIAGRAM TLS uNDLORD ANDLORD DETAILS POWER PU LIGHTING PUN ELECTRICAL PETALS ELECTRICAL SCHEDULES ELECTRICAL SPECIFICATIONS L NCi ORD DETAIS (ANMORD DETAILS cau 0i1011.1_, APPRD n �16� GUI NGOMStON / REVISIONS NO. DATE COMMENTS 33% -oI)u NOTES AND SCHEDULES ,• _.. RESPONSIBILITY SCHEDULE ,• FINISH SCHEDULE CABINET SCHEDULE .STOREFRONT£BARRICADE NOTES '(IF'APPLICABLE) L DOOR SCHE ITEM e 2 r "PABQ SUPPLED BY GENERAL CONTRACTOR AND APRJED BY GENERAL. CONTRACTOR. (REFER TO SPED. OMSION I%, SECTION C - PALMING. FINISHING AND WALLOYFRING) P -1 (NOT APPLICABLE) P -2 BENJAMIN MOORE - 'BLACK' - SON SATIN IMPER'vD RASH N0. 235 - 80, MIXED ,WON 501 MT 6ucK EHNALL P -3 - (NOT APPLICABLE) P -4 CALLER TRIPP - SUPER POLY - 7143 WATER BASE POLYURETHANE - CLEAR SATIN FINISH WOOD SSEA. NON-SALES ELVFB ) P -5 .. BENJAMIN MORE - 878 - 'OVERT - SENT -GLOSS FINISH P -6 GUDOOH - 'TUSK -R5K 301,79070 - (OFF WHITE) - EGGSHELL FINISH P -7 (NOT APPLICABLE) P-5 0 GUDOEN - 'TUSK -TUSK 30W79070 - (OFF WARE) - MT FINISH P -13 - BENJAMIN MOIRE -- 1323 -'RED' - EGGSHELL FINISH P -14 BENJAMIN MORE - 164 - 'FRENCH VANILLA" - TEXTURED FlNSH MEMO STIPPLED MID MSTALIID BY GENERAL CONTRACTOR (REFER TO SPECS. OMSXIN VII, SECTION C - CLASS AND GLAZING) M -1 1/4 CLEAR PLATE GLASS MIRROR - SIZE AS NEEDED. GRIND /POLISH EDGES TO CREATE A SAE. FINISH. N. FlNIRHFS SF -1 WHITE 1/4' MOUE PANELING W/FACTORY ALUMINUM EDGE 6. CORNER MOULDINGS, was ADJACENT TO SERVICE SINN - R TO NOTE ON OETNL A/9.1 TOR. SUPPUEO AND INSTALLED BY GENERAL CONTRAFUTURES SF -2 ( LE) (NOT MPUCPB SF -J (NOT APPLICABLE) sF -4 (NOT APPLICABLE) SF -5 17 % 17 SENEG ANDMOO, IVORY. UNGLAZED, PUSHED. SUPPLIED BY OWNER, INSTeum BY G.C. SF. -8 4' x 4' CERAMIC TILE, WHITE AND CREAK PIECES, GLAZED. FOR COUNTER IN DEMONSTRATION AREA SUPPLIED BY OWNER MID INSTALL BY G.C. ARRANGE TI GROUT IN A RANDOM PATTERN. REFER TO DTI_ F/7.2. GROUT TO BE LATCREIE, CANDLELIGHT 084, WTI 1/8' WIDE GROUT JOINT. GROUT TO BE SUPPLIED AND NSTALED BY C.C. SF -7 4' ' x 4" CERMIC TILE, RED,WNITE AND CREAM PIECES. GLAZED - FOR BACKWALL OF DEMONSTRATION AREA SUPPUED BY OWNER MD INSTALLED BY G.C. ARRANGE TILE IN A RANDOM PATTERN. REFER TO DTL F /7.2. GROUT TO BE UICRETE, CANDLELIGHT /84 W. 1/S WDE GROUT JOINT GROUT TO BE SUPPLIED MID INSTALLED BY G.C. FL0 OvERI TI SUPPLIED (RU TO SMSbN 1X, ON SPECS. O N IX, SECTION 0 1HPV SECTISECT CONTRACTOR. UNLESS NOTED O 0R C LED B( OWNER 10 AND INSTALLED J) ro -1 (NOT APPLICABLE) FC -2 (NOT APPLICABLE) - FC -3 (NOT APPLICABLE) FC -4 (NOT APPLICABLE) FC -5 - (NOT APPLCABLE) FC -B .(NOi APPLICABLE) FC-7 17 M 17 NNR TILE - ARMSTRONG EXCOI O N NO. 51901 'TMJP7, RIPERLN lE%NRE. -FOR MN -SALES AREA SUPPLIED AND INSTALLED BY G FC -B i7 % . 1 0 1 - AN 00 00 EXCELON N0. 519,2' AND I FI, NPEPOAL lE%NRE -FOR NON -SHED FIRE ONE. SUPPLED PAID INSTALLED BY C FC -9 (NOT APPLICABLE) N -10 Y % 17 PRE NSXED WIRE /WOE FLOORING PO -11 POR ROM ONIV Wit/MOB CL MULTI-PIECE 'NATURAL WOOD' /GREEN TRIM CABINET W11H. MATCHING UPRIGHTS, 1. GEN. CONTR. IS TO CONSTRU A STOREFRONT BARRICADE PER LANDLORD /MALL SPECIFICATIONS. CT` ... - p , IF UNDLORD /Mill XAVE SPECIFICATIONS, AT THEN: GEN. CONTR. IS TO CONSTRUCT TEMPORARY B" BARRICADE(5) OF 3-5/8" METAL STUDS 24' O.C. WITH ONE LAYER OF 5 / GYP. BD. (MALL SIDE) TAPED AND SVACKLST SMOOTH ":INSTALL A 4 MIL PIASRC OR UY BD. BACK TO MALL BULKHEAD TO:CREATE DUST -PROOF CONDNION. SUBSTITUTE GYP. BD. AN D PLASTIC WINE'S /8" EXTERIOR GRADED PLYWOOD, FULL HEIGHT, AT EXTERIOR' STOREFRONTS. BARRICADES ME TO BE BmRIC IELY USr SECURED S BRACED TO MALL BUII(HEAD FRAMING FOR LATERAL STABILIF4 AND BARRICADE MUST BE SMUCTURNLY SOUND: , , :. 3 pRINE AN PLANT BARRICADE P -2 . GENERAL. CONTRACTOR TO INSTALL OWNER- SUPPLED GRAPHIC WALLOKR LNG ON B,E" AN CONTACT OWNERS CONSTRUCTION MANAGER TO OBTAN MATERIALS AND INSTALLATION INSTRUCTIONS.. 4. CARE 15 TO BE TAKEN WHEN OISASSEMBUNO AND REMOVING BARRICADE. GEN. COMB. IS TO RESTORE MALL MOORING MID BULKHEAD TO A 'LIKE NEW GNOMON AND FlNISX. 5 GEN. CONTR. TO CONSULT MTH MALL REPRESENTATIVE FOR HOURS IN WHICH WORK ON BARRICADE CAN OCCUR. ND' 812E TYPE FRAME DETAIL HARDWARE NOTES - SS ESI NSJ 3SJ S 3 S I : 20 WDE 'ROLLING GRILLE STEEL POSTS AB/5.1.A/5.2 B.C,D 2. 3 0 x ] -O SOLID CORE " HOLLOW METAL H,J,M /8.1 % RN NBR Pas SUxmIEUA FR615T MATERIAL Awxeils SHELVES AND V LACE (OWNS" MAS 0 K CAL PANEL - G C. 0 NRNISH AND INSTALL MIRROR WIMIN). O MULTI -PIECE 'NATURAL WOOD' /GREEN TRIM CABINET WITH MATCHING UPRIGHTS 3 3 O x ] " HOLLOW METAL HOLLOW OFT. D/9 .1 H, P 4 3 0" z ]' -0" HOLLOW. METAL HOLLOW METAL D/9.1 F' 5 3 0' x 7' - O" HOLLOW METAL HOLLOW METAL D /9.1 L,M,N,P PRmxSHm AETA1 PARIS N PREM.° • SHELVES AND VALANCE ((CABINET HIS. NO BACK PANEL G.C. TO FMRNISH MID INSTALL MIRROR WRHIN). _. - ON MULR -0IECE 'NATURAL IVOD' /GREEN TRIM CABINET WITH MATCHING UPRIGHTS. , stMS 00.65 mow. NOTED • • °N DMWNGS) ROwKC CRILE(5) 1F11PEtfD PIAIE 41,44 MD/. t ENIiR ODORS • • SHELVES AND VPJ.WCE (CABINET H B ACK PANEL - C.C. TO FURNISH AND INSTALL MIRROR WITHIN) OP NOT USED - . - , O NOT USED • • •.. , ...• - • �. - - NET 410EFIONT.OL(DM M. • REFER TO SPECS. DIVISION VIII, SECTION A - DOORS AND HARDWARE " 'N 'AL 110 1)0. RJ: GYPSIM exam Muss WMLA ETC. AN ROOMED FRS AND BOONNO O NOT USED 5 MULTI ^E ^F "ATU° VO B/ E FRED IN W. OLDERRO FOR AIL r.5 IN F EFlNEHED WALL DISPLAY CHINE SHELVES, • • cun ••c. Au, WI eurr (newMFT IC OPPU u0 BArK PeMEI/un Loom-K _ r MULR -PIECE 'NATURAL WOOD' /GREEN TRIM CABINET wall MATCHING UPRIGHTS, SDI OBrf RICO TILL Br ORIIH wNM MeM O[RATON (ALAI(.. •• •" -•' - - - - Know, WORK, LAME PANELS ETC INTERIOR DSPIAT CAIXNET MIRRORS PARRS., CA.Er BAY • • • • LNG M wni, 'B' SELF SUPPORTED R LL-UP GRILLE WITH MOTOR OPERATION (MIN. - 120 S0. FT.). SUPPLIED AND INSTALLED BY OWNER.. ELECTRIC.. CONTRACTOR TO SAKE FINAL CONNECTIONS. GRILLE TO HAVE CIE. PLEXIGLASS INSERTS THE ENURE AREA OF CURTAN. .4 ROLL-UP GRILLE TO HAVE ONE CDT. LOCK IN BOTTOM RAIL- USE DOUBLE SNIDE BAR WITH SINGLE CENTER RELEASE. USE PANIC RELEASE HARDWARE INSTALLED BY G.C. FOR MOTORIZED GRILLE TO MEET CODE REQUIREMENTS - 'D' G.C. TO PROVIDE AND INSTAL SIGWGE ON STORE S1DE OF BOTTOM RAL OF GRILLE STATING, 'GRILLE MUST REMWN IN FULL OPEN: POSITION. DURING SPORE HOURS WHEN E GENERAL, PUBLIC. GRILLE SHALL BE OPERABLE FROM STORESIDE WOLR : OCCUPIED BY M TH THE USE OF ANY SPECIAL KNOWLEDGE OR EFFORT WHEN SPACE IS OCCUPIED,. ... '[ (,.vT r uv AOI'1?j - - - "F LAVATORY DOOR: UNFINISHED DOOR AND FRAME SUPPLIED, INSTALLED D FINISHED 6Y C.C. INSTALL PRIVACY PUSH BUTTON LOCKSET - RUSSIAN 1821) WITH LEVER TYPE 772, FINILH TO BE US26D: HINGES - SIMILE) /F1313I79. (OR EQUAL) STARLESS STEELS FlNISX. 1 -1/2 PAR PER DOOR; CLOTHING NOOK NO. 5000, ALUMINUM FINISH BY BRASS WORKS (OR EQUAL) PROVIDED AND INSTALLED BY C.C. CENTER MID MOUNT ON LAVATORY WORKS SIDE OF DOOR • 77 RF.F:; GLASS MIRROR - 20' X Sr . (ALL EDGES OF MIRROR TO. RECEIVE ( RUIN EDGE W SMOOTHED M I POLISHED NN W MI . N LOP TI MOUNT N CHANNEL (SE( ET MIRROR ITH RROO R IN MASTIC) PRONDED DEO MID NSTUICn EN G.0 G.C. DEARER AND NOM L ON LAVATORY SIDE OF DOOR 14.1 TOP /MIRROR • 70' A.F.F. O.C. TO PRONOE AND INSTALL COMMERCIAL GRADE WALL MOUNTED DOOR STOP AT KNOB HEIGHT. SHELVES AND VALANCE (CABINET HAS NO SACK PANEL - G.C. TO FURNISH AND INSTALL MIRROR WITHIN). WALL DIRpI AT (:MINK NOM PREM.. WALE BASE AND COLUMN BASE • • PARTITION'. AND COLUMN NOTES : - PRDIHSNW PINE P.m. • PRBINSHED .. .WIOHl WADER WARD 90M • • 1. FOR CABINET SIZES AND INSTALLATION INSTRUCTIONS - REFER TO CABINET BETNL SHEETS. 2. PRE - FINISHED CABINETS AN- SUPPLIED BY OWNER AND SHIPPED TO JOB SITE UNASSEMBLED. G.C. IS TO ASSEMBLE ALL CABINETS REFERRING TO CONSTRUCTION AND INSTALLATION DETAILS OF THIS SET. 3. ETCH WALL CABINET IS TO RECEIVE SHELVES - C.C. TO INSTALL. REFER TO RESPECT. DOTAL SHEETS FOR INDIVIDUAL QUANTITY/INSTALLATION INSTRUCTIONS. 4. UNDER NO CIRCUMSTANCES ARE THE WIDTH OF THE CABINETS TO BE ALTERED. 5. REFER TO SPECS. DIVISION X, SECTION A - CABINET WORK, FOR ADOMON. CABINET INFOR- MARTIN. MASSING WALLS GENERAL CONTRACTOR TO COCATED INSTRUCTORS ONFIRM ACTUAL FIELD CONDMONS : # AND COMPLY WITH PREFlxsxEO w WOOD l OrnN,A TIKE p...,,,,,,,,,,, iOW BUM R.N.. GSH/WiAP ...RS I - E %ISMNG DEMISING WADS TOM TO DECK: # REPAR DRYWALL SURFACES TO LINE NEW CONOMOM - EXISTING C WALLS SHORT OF DECK: INSTALL URED TO # MP E AD DMOSIN NET. i AND DRYWALL /S REQUIRED COMPLETE DEMISING W. TCM TO DECK. - EXISTING DEMISING WALLS SHORT. OF DECK - REQUIRED ' WE TO COMMON HMG PLENUM AND APPROVED BY BVIOING DEPORTMENT: '. *INSTALL O VE x7 'ORE N US POV E OWNERS COCSMUCi .M OF PANT. OF F AC A To OECD ABOVE FIELD CONDITIONS, N OR O N ORDER DER TO BT TO OBTAIN SPECIFIC INSTALLATION bn /ANN. INSINSTALLATION INSTRUCTIONS. N INSTRUCNS0 I ® NEW DEMISING WA. (METAL STUDS - BY'LANDLORD): w FLOOR FUTURES SAI,s AREA PGR tl.45 m.o. m.o. M`t) PREENS. WL MART Si- EVES AT DUMSIMRON NEA • • OEMONSIR TASW AND M S UucLT YT PAINT NOTES NRMNRE IN n.3.-... S • • PMPm:NED WOO ROOM, AMEMVE NO Ct.. • 1. C.C. IS TO PRIME ALL GYPSUM BOARD WALLS, SOFFITS, FASCES AND CEILINGS. 2. REFER TO SPECS. OMSION IX, SECTION C - PANTING, FINISHING AND WALLCOVERING }. C.C. IS TO LEAVE ON SITE A MINIMUM OF ONE QUART OF EACH COLOR OF PLANT USED. CFnwK TAO FOR ooAO1N4MAMpM ARM COUNTER i # # SPEOFlC GYP. BOARD WSTALGlIM INSTRUCTIONS TO COMPLY W/ LANDLORD CARER. - NEW DEMISING WALLS(MET/L STUDS EN TENANT G.C.): : # SPEOFC GYP, BOARD GRADATION INSTRUCTIONS TO COMPLY W/ LWDLOO CRIIFAN. : INTERIOR PARTITIONS ' 3 -5 8 METAL STUDS AT It O.C. (ID IMUN) WTIH - "J (,.OT , rd'fLCAG.n - - 'K NON -SALES DOOR: UNFINISHED DOOR, FRME AND HARDWARE SUPPLIED, INSTALLED AND FINISHED BY G.C. INSTALL KEYED - RUSSIAN /855 W. LEVER TYPE 772, FINISH TO BE U5280; HINGE - STANLEY 0139179 9 (OR EDUAL) STARLESS STEEL FINISH, 1 -1/2 PAR PER BOOR. "(' EpWT Poq tUyND TRE A• PAWS APU FLOORING AT ENTRY NON-SAES RODAO Ate WALE RASE (.T) • • SALES AREA WALLS PALM All G P SUM BOARD WALLS NOT COVERED B CABINETS. ANAL COVERINGS P -B FINISH MIRRORS OR SPECIAL FINISHES, UNLESS NOTED ONERWSE ON 111E ' FLOOR AND WALL FINISH PUN' OR ME 'INIEItIOR E]£VARONS'. WALL AT BACKWRAP FINISH PAM PL1W00D BEHIND BACKWRAP, SO IMPOSED PLYWOOD AT BACK OF QUI REVEAL MOVE BACKWRAP RESEMBLES WEATHER BOARD SIONGFlNISH - REFER TO DTL E/7.1 . WALL AT BASKET AREA GTE FINISH PAINT BACK GYPSUM BOARD WALL AND FURRING AT BASKET AREA CEILINGS AND SOFFITS FINISH PAINT ILL EYPSUM BOAR. CBUNSS, SOFFITS MID FASCL 9, UNLESS N01ED P -g OTHERWSfON THE 'INTERIOR EATIONB. WALL ANTI COLUMN BASES NOTE: .L WALL MITI COLUMN BASES ME PRISINISNED, AND PROVIDED BY OWNER roR INT BY G. METAL D ALES AREA S AND FRAMES (IF PREFlNISHED WOOD DOOR IS NOT USED) P -B ALES OE OF METAL oaoR AND FRAME (0 -6 ) S (0-5) NON -S 3 AREA SIDE OF METAL DOOR O L (NOT APPUQeDL) .. _ _ _. - WALL CO N.R*S AND ROTOCRFHIt WRN • • LAY-P1 COMBS HOLLOW META DOORS. FAMES AND HARDWARE • • - 5/d GYPSUM BOARD. PROVOf TYPE 'X' BOAR 506 TO TO AN .0) HOUR RATED FIRE PARTTON - NO TE: WALLS TO SUPPORT NON -SALES WALL MANNA. ARE TO REC EVE' 20 G MR: SUDS A TDO178 ]CCBRrTY TEED •, .GE (OR CpIM.) T�HL .. TER TINS I - - - - ' - SERVICE DOOR: S ED DOOR "L' STANLEY /FE B179 SECURITY STUD RITE DP (OR UD HINGE (OR INSTALLED , FI ESSD BY STARLESS STEEL G N. HINGES . - PAIR BITU HINGE EQUAL), SL SMO FINISH, 1.1/2 PAIR PER DOOR. "M SERVICE DOOR: G.C. TO PROVIDE MD INSTALL THESE TIERS: (2) HEAVY DUTY INDUSTRIAL BY GLYNN- JOHNSON (OR SQUARE SUDS BOLTS, 1700 SERIES. //170878, MANUFACTl MANUFACTURED 8Y LATCH -GUARD INC.: :TU EOU.)L S X 11" TAMPER -PROOF LATCH COVER, MANUFAC FULL DOOR MUM SEAL/SWEEP, STANLEY /5070 - U528 NEARED ON Ea. SIDE AT BOTTOM 0 HIGH 8? RODENT OR WATER PENETRATOR: PERIMETER WEATHER .SMIPPING ON EXT. DOOR; 10' HIGH BY FULL WIDTH BRUSHED ALUMINUM KID( PLATE MOUNTED 1" FROM BOTTOM . OF DOOR; PEEP LE HO CENTERED IN DOOR AT 54" A.F.F. AND CLOSER WOVE STAINLESS STEEL FINISH N0. X9120 PARALLEL ARM CLOSER MANUFACTURED BY RUSSIAN CO. MOUNTED ON STORE SIDE. G.C. TO INSTALL OWNER SUPPLIED PANIC RELEASE/NMN' LOCK CENTERED AT -45' A.F.F. (OR SPECIFIED BY CODES). "N' SERVICE DOOR: C.C. TO INSTILL STORE. SIGN LABEL ON OUTSIDE FACE OF ODOR CENTERED AT BC AF.F. SIGN IS PROVIDED BY OWNER. TA 'P DOOR AND S. C.C. BE (1) HOUR TIRE 0 CL S' LIBEL T0. COMPLY STEEL FINISH N0. FOCAL AND MANUFACTURED BY RU55MN COMPANY. PERIMETER OF DOOR TO RECSKET. 000IJ CODES. G.. US WIN C AND INSTALL CLOSER 7000 R IS ISI TO RECtlYE A SMOKE GASKET. SKET. (UNIF55 NOTED OTIFRMSE). ' ': GY GYPSUM B STUDS 1 O.C. (ON OA R . I1) 8' EIMUM) ITTH 5 /8' - GYPSUM B REQU I PROVIDE TYPE ' %' ONE OR BOTH SIDES AS REQUIRED. - NOTE' WALLS TO SUPPORT NON -SALES W. STANDARDS ARE 11) RECEN - T 20 GA MT L STUDS. (UNLESS NOTED OTHFAMSE). NOTE' BOX ON CONSTRUCTION PLAN WILL INDICATE: DIFFERENT SIZE METAL FRAMING /FURRING TO BE USED ❑ INSTEAD OF 3 - /B NET. STUDS.- E AMPLE: TRAC ® N A R 2 1/7 METAL STUDS ARE T BE USED. STUD 3 we (20 GA) METAL STUD/TRACK • 18 0 C (MAX). H pDDW ,gTM. 6.5 / NOI_SMf DOOR FRAM - • • HA ppENN SALES / NON-SALES DDCR MO HARDWARE • • • BIRlEIw'gOVOS ALAN TUBE SURFACE Wuxlm STANDARDS. MRADKEI4. M. HOOKS. wRT. an • • SF4W IN NDNSAES AREA, LN_ TIC... BOP CORNER S GUARDS PR0 ECDh qE. ANA • FIOM SOME SINK WM 47 MY • • WANE AT SOOT a va REFER TO 'CONSTRUCTION MAW FOR LAYOUT. ® -. SECURE 1" X 7 -WARE MESH TO ONE SIDE OF PARTMON - (RUN FULL YAM AND OF W ELCH INSTALL 7: _. i� 'Ram-Wm MOP .DER 5114. 5114. 5.P) AM HOSE HOLM (�� sI D FUR IN 8 ROWS OF 1 % 6 W000 FURRING EACH SIDE OF STUD PER DETAIL 0/12.1. SCREW TRACK TO - _T OR TO WRAP ALL STRUCTURAL MALL STUD 12 O.C. COI IINN 507111 COLUM NS CONTRACT FIANOCW DRAB BRAS 10 PA E GVAOO' LOOT PAPER Am PAPER AND TEL BOBBS COLUMNS LEASED 0 GYPSUM VERTCP ON BOARD TYPE E I I N FIRE -RAPED 2 4000 501. BY 011 S 0 00 0 TO OBTAIN EACH SIDE. REWIRED RATING AS ESTABLISHED STATE AND LOG. CODES ,WD /OR BY LANDLORD. .: COLUMNS ARE TO BE WRAPPED AS TIGHT AS POSSIBLE OTHERMSE ON DRAWINGS. MINIMUM SIZE ENCLOSURE, UNLESS NOTED OIHFAWISE • GVNOW MIRROR MIRROR - - - -- -. FIRE ESTIH•MPER4 „ R F ( vE R n A REAR DOOR ALARM • • S" x. 'FLORIN TILE'. IUTUPA LIBERTY SERIES 18803 (PPRCHMEM) SUPPLIED Jk INT.. BY C.C. F0-12 IN % C TILLED BY S INONSPOT. 0 IOM. UNGLAZED: RUSHED. SUPPLIED BY OWNER INS BY D.C. G. GROUT GTICEIE. P 0 181, D BY 3 /18 WIDE GROUT JOINT. GROUT TO BE SUPPLED U01 AND D INSPALIID CC FC - (NOT APPLGBLE) ro -14 (xOTAPPLCJSU) FC -15 FOR FI OCR AND WNI APR00105 NON -SALES AREA WALLS M FINISH PAL ALL GYPSUM WALLS AND WA PALO E%PpSO .1 SANDS. CEILINGS PO-5 FlNISX PANT ALL ORSON BOARD CEILINGS. METAL DOORS AND FRAMES P-6 FlNISX PAM ALL METAL DOORS PAID FRAMES (FIELD APPLY/ ONE COAT LATENT PRIMER - IYrD COALS FINISH) WOOD SHELVES 1=1 FINISH PAINT ALL .OD SHELVING. - A C J wn ). °C u_ura 4*10 V twn wr 81111 4 nnur1E 100( um 14L44 awuA R: wm. AAA•N IN. e° EMT AIMS 5 1<CY OrDNTED G3'91DC WADI TIBMO ieRN OOIDL 10 _ ... _ _ _ -. - _ •-- - AREA LAW 00400004 (WRn 11020) ' µ0 MR TT • • �- - - •.• '- • - ". "� -. - � ILL HOR -SAES MR MUMS (ERN LOPS) .. • - • "" �� SPEAKER ENCLOSURES, RARE AO M. • • 1N -WALL BLOCKING NOTES _ SF EAEN LIN M NON-SAES • • NO DBOC1 IMIBNB ALLOWED. Own !,CLAW Am -.W KA 4 ^Dw u -. - . . 0 GONER. COMRMTOfl IS RESPONSIBLE FOR INSTALLATION OF IN WALL BLOCKING FOR ALL WALL HUNG HEMS IN STONE 1)2 RENEW DECORATIVE PRESENTATION ITEM DETAILS OF THIS SET TO INSURE THAT ALL ITEMS HAVE ADEQUATE IN -WALL BLOCKING: E O CHMOUT M O MI ' FLOORS: AMERCE OLFM -7x7 PORCELAIN MOSAIC - 'BONE OR EW. BY DAL -TU, SUPPLED AND INSTALLED BY C.C. WALL S: 000 (0.. OLEA N -4 I/O N 4 1/4 TEE - WEE GLAZE "BONE OR EQUAL BY 011 - TEE (4.C. TO USE ALL APPROP TRN PIECES, BULLNOSES. COVE BASE. .. rt! T y u °u , M OF OCvR "K SASS /NON -SALES DOOR: PREFlNISHED. SOLID WOOD. DOOR. PUSH PLATE AND KICKPLAIE p1OVIDED BY OWNER, INSTALLED EN C.C.; HOLLOW MET. FRAME AND HINGES PROVIDED MID INSTALLED BY G.C. - HINGES TO BE STANLEY /FBB179 (OR EOU.), STARLESS STEEL FINISH, 1 1/2 ANN. G.C. TO INSTAL PUSH PUTT AND KICKPUIE ON SALES 510E OF DOOR - REFER TO DETAIL J /e.i FOR MOUNTING HEIGHTS. "Y 9ALBS /NON -SALES DOOR: G.C. TO PROVIDE AND INSTALL THE FOLLOWING ON THE NON -SALES SIDE OF THE D00R: PULL PLATE WITH HINDU - NES 18302 -6 3.5415, SATIN FINISH (8281)), RUSSIAN PARALLEL ARM DOOR CLOSER /HOOK 19120. SATIN FINISH (U528D); HK TYPE DOOR STOP /HOLDER - IVES #450 - SATIN FINISH (8280). 7 10 OF RUSRUSSIAN 772 HANDICAP USER HANDLE TO BE USED AR SPECIFIED ABOVE. 0 `JLNG ONISMOe' crnrOVCFNIA APR 2 9 1996 CUTER PRESMTAlION RDAs • TO P oRA.wO4 a 1H9M9 ST COVE DOSE, ETC..) SUPPLED AND INSTALLED BY O.C. WN mNSIN ;5 / :' SUPPLIED BY 00NER AND 1 0 01414 1 0 BY GENER/ CONTRACTOR. wagL5 : (REFER TO SPECS. DIVISION 10, SEOON 0 - MONO FINISHING AND WNLCO.ERING) BWC -01 PAINTED 4 1/4 RED GINGHAM CHECK, NNUMOUAL ARTWORK ON CANVAS BWC -02. PHOTOGRAPHIC AURAL 8WC -03 : 'PANTED 8' GINGHAM CHECK, IND1440UAL ARTWORK ON CANVAS ENG -04 SEASONAL PHOTOGRAPHIC MURAL (4 PANES/SEASON) AM M WA L 1 SUPPLED BYOWNER AND INSTALLED BY GENERAL NiRPCTOR. 1P Cf:) 1 � ERMIT •11111111.. gi CI (0,/:;? 4 (TITTER TO SPECS. 61 N, MOONS A THROUGH E) 0 0 -01 PREFlNISHED WEATHER BOARD SONG AND TRIM (DISTRESSED RED FINISH). REFER TO DETAIL "A' ON SHEET 8.1 FOR INSTALLATION DETAILS. BAC -02 PREFlNISHED •1E0 -57010 PINE PLANKING WITH 0280 EDGE AND TRIM. REFER TO STORMONT DETAIL SHEETS FOR INSTALLATION DENNIS. • PWIMIM WORK (AS MGM) • • MECHAN.. WAR( (AS SPECIFIED) • • • R.N.. WORK (AS SPEWED) • • • TIRE PM1500DN NO. (A EPDXIED) • • ` r t, 1 E RGO E C T R B Bath per' Body �] a yy "`� " O J 111)1 Works THREE LAIRD PARKWAY COLUMBUS, OHIO 43230 514 -479 -700 NOTES &SCHEDULES ;� u a ATE SEATTLE,N WASHINGTON a,,,,,, - , sNA8 NOTED 'a.T, Y l awn RING 1.1 Tnrn1111I 11111 rnIlllnl an5T7nTnr ill n l➢n n i n aur1f1IIm rTITTn111m1I n111)l)T11)Tlr1'rfl llr)Tnjl f11lilMr11 X1:1 • FOR ALL NOTES AND SCHEDULES: SEE SHEET LI • FOR ALL CEILING TRANSITION LOCATIONS: SEE SHEET 9.1 •'FOR ALL FLOOR FINISH LOCATIONS: SEE SHEET 4.1 • FOR ALL PRESENTATION ITEMS 70 BE INSTALLED BY O.C.: SEE SHEET 10.1 PLAN DIMENSION NOTES • ALL WALL DIMENSIONS ARE TO THE FINISH FACE OF GYPSUM BOARD ON WALL. IN-WALL BLOCKING NOTES 0 GENERAL CONTRACTOR 15 RESPONSIBLE FOR INSTALLATION OF I0 -140.11 BLOCKING FOR ALL WALL RUNG ITEMS IN STORE - THIS INCLUDES BOTH CONSTRUCTION RELATED AND DECORATIVE PRESENTATION ITEMS (0 01 RESPONSIBLE TO REVIEW ALL PLANS AND DETAILS WITHIN THE SET BEFORE FRAMING STARTS) MANAGER'S UTILITY AREA PANELS NON -SALES AREA FIRE CORRI OUR RATED CEILIN. NALL51 D 24' 24' 24' 2T 2 BASKFT AREA FRAM / . NOTE THIS AREA REQUIRES SPECIAL IN -WALL BLOCKING A 0 HAS SPECIAL FRAMING REQUIREMENTS AT CEILING LINE: RE ER TO DETAILS ON SHEET 3 BEFORE CONSTRUCTING. SALES AREA END PANE 9' 10111. FROM FACE OF METAL STUD) M MBUS. OHIO 13230 LEASE LINE EXTENDED LEASE LINE 8 T/ ' CONSTRUCTION AND FIXTURE PLAN SOUTHCENTER MALL EATTLE, WASHINGTON q 1T! r I. la.l. 1 v1' - r-o• 1-I►96 FOR SPECIFIC NOTES AND DETAILS PERTAINING TO H.C. LAVATORIES AND SINK ROOM - REFER TO DETAIL A /9.1 . NO19L8ALE8 SHELVING NOTE ALL NON -SALES SHELVING TO BE TYPE G -5 /SHEET 9 -1 UNLESS NOTED OTHERWISE PATCH AND REPAIR PAINT TO MATCH MALL FINISXES FD 21' -O G.C. TO INSTALL 5 /8' TYPE '0' GYP. BD. ON BOTH SIDES OF 3 5/8' METAL STUDS. RUN FROM TOP /SLAB TIGHT TO DECK ABOVE. (THESE WALLS ONLYI LAYOUA LAYOU P OINT F POINT t56 -OiI'L - 'nPPUWIIIPIIUIfITI 5 FflhiFf97IU1111 R -1 02' 0' 0010 FACE OF METAL STUDS FLUSH u /FACE OF RATED' COLUMN ENCLOSURE 1 179 PII nqT I . 95 IS -3 1/2' 24 DIM FROM PACE OF METAL STUD) G.C. I8 TO RECEIVE, UNPACK, ASSEMBLE AND SET IN THE CENTER OF THE BALES AREA ALL. OWNER SUPPLIED 'BATH & BODY' DISPLAY FIXTURES AND PRESENTATION ITEMS. (DISPOSE OF ALL PACKING MATERIALS ACCORDINGLY/ • FOR L, M,' N. P, N, & 8 CABINET DETAILS: SEE SHEETS 61 & K2 .I B.C. NOTE: UPON COMPLETION OF CABINET INSTALLATION INSPECT EVERY CABINET TO MAKE CERTAIN THAT EACH DOOR HANGS PLUMB/TRUE AND AT THE SAME TIME RE- TIGHTEN ALL HINGES ` L AYOUT ® LAYOUT P OINT POINT 6',...0 10 •}e14 reliO 601 Are ° pL� LPs+ G.C. TO FURR OUT FROM EXISTING RATED DEMISING WALLS ✓ 0 /0' GYPSUM BOARD OVER METAL STUD FRAMING 1. 10' O.L.I. RUN FROM TOP OF SLAB IOM NALL BASE AS APPLICABLE( TO NEW STORE CEILING HOLD FACE OF METAL STUDS FLUSH ✓FACE OF RATED' COLUMN ENCLOSURE. cAnigvm APR 2 91996 PERMIT 1. - 29' -6 1/4' 1117(2 LINUEO PARNWAY 1 GC. TO FURR OUT FRON EXISTING RATED DEMISING WALLS ./ 0/8' GYPSUM BOARD OVER METAL STUD FRAMING IF 16' 0. 01. RUN FROM TOP OF SLAB (OR NA11 BASE AS APPLICABLE( TO NEN STORE CEILING HO PACE OF METAL 91209 FLUSH ./FACE OP - 72100' COLUNN ENCLOSURE CONSTRUCTION & FIXTURE PLAN Bath & Bod Works STOREFRONT ELEVATION 0.0. NOTE. STATE AND /OR LOCAL CODES MAY REGIME THAT ALL WELDINO OF STRUCTURAL STEEL BE ACCOMPUSHED UNDER THE SUPERVISION OF AN APPROVED ENGINEER AND /OR INSPECTOR. THE GENERAL CONTRACTOR 18 RESPONSNILE FOR THE ACTUAL VERIFICATION OF THIS REQUIREMENT. AND THE COST OF SUCH SUPERVISION OR INSPECTION WHEN REQUIRED. NON -SALES NOTES o f DECK ABOVE: 6' METAL EXISTS 116 GAUGE, AT 16' O.C. NIT* SA' GYP. BOARD BOTH BEES. COVERED HTH 3/4' NON -COM /1011000 AND TRIMMED WITH I.1 POPLAR. TOP OF DECK AT 0' -0' AFF. REFER TO DETAL 5/91 O BULLENTEE TIN 13,0440: Af.F EN: GERAL CONTRACTOR TO INSTALL 36' X 48' BOARD PROVIDED BY OWNER. BOTTOM OF BOARD IS MOU O PREFINISHED METAL CORNER GUARDS: SUPPLIED BY OWNER AND INSTALLED BY GC. MOUNT BOTTOM OF GUARD TIGHT TO TOP OF V1NTL BAS O PROVIDE SHELF FOR MU51C SYSTEM AT 04' A F.F. ELIMINATE SHELVING ABOVE OR BELOW MSC SYSTEM SHELF HRH 1E50 THAN IZ' CLEARANCE. O GC. TO INSTALL 3 1/2' ACSTIC FIBERGLASS BATT NSULATOM M NALL BETWEEN HC. LAVATORY AND SALES AREA. RUN INSULATION FROM TOP OF SL TO 12 - ATP. • ASTERISK MONTE. NO NEWSOM MLOE TO 1Y/ MEET SALES AREA LAY-III MEW NOTE • ALL GEEING TRANSITION DIMENSIONS ARE TO TIE FINER FACE OF GYF801 BOARD CEILING NOTE SOLD IDES INDICATE f OF SUSPENDED METAL IN GRID/EDGE OF LAY-N 11.0. DASHED LIMB /DICAT'S SCORE LINES ON FACE OF LAY-IN TILE PLAN DIMENSION NOTE • ALL GEEING TRANSITION DIMENSIONS ARE TO TIE FINER FACE OF GYF801 BOARD CEILING NOTE O _ OVAL IIDDATEB THE /118880 IEIGNT OF 019801 BOARD CEILING ABOVE F 1(81ED FLOOR. START CEILING LGOCATION HIS 2 LAVATORY (BELOW OPEV FROI TOP 11 CK 13 MAT/ CMG. BO V� 2 x *' LAY IN CE.LIN / 12'•0' A.F.F _z X96 -01i�- FIRE CORRIDO II -HOUR RATED EILING /HALLS • E3 iliia niari 1111® ®111111111111 C D' 2 1/4' START CEILING'' GRID AT THIS LOCATION 2 x 2 LAY -IN CEILING r STAR CEILING GRID AT THI LOCATION EQ.- 2 2 LAY -IN CEILING 9' -8' A.F.F. b i. --START CEILING GRID AT THIS LOCATION P. oe LINE OF DECORATIVE HOOD BEAM IRE ER TO OTL. F /82) I • o 1 D 14— r - OF DECORATIVE BE 15 TY ICAL) r - - -f - - y ACE - ■ G.C. TO PROVIDE BLOCKING ABOVE CEILING FOR OWNERS' HANGING SIGN. REFER TO 'LIGHTING PLAN' FOR LOCATION. REFER TO 'PRESENTATION PLAN' FOR DETAIL x 2' TEGULAR CEILING TILE RE ER TO TITLE/ SPECIFICATIONS SHEET LOCATE C OF LIGHT AT CENTER OF SCORED AREA EoTE: TILE SCORED IN 12' PATTERN ITYPICALI CEILING TILE DETAIL crry APR 2 9 1996 PEW,' CENTER _� 1111 SCALE. 1/1' • 1'-0' Bath & Body Works 1HRCE LIMNED PARNWAY COLUMBUS, 0)110 43230 614 -479 -7000 LEASE LINE G OF GRILLE EXTENDED LEASE LNE I<--LINE OF AANG PROVIDED IINSTALLED BY OWNER T, S PREFINISHED WIRE GRID NTH 6' SPACING. PROVIDED BY OWNER GC. O CUT TO K -O' TYPICAL OF 21 REFLECTED CEILING PLAN ® ASTERISK INDICATES FRESH FACE FO GYPSUM BOARD SOFFIT TO ALIGN WITH FNBN FACE OF WALL BELOW. REFLECTED CEILING PLAN SOUTHCENTER MALL SEATTLE, WASHINGTON eC VF - ra revised r9-16 ASTERISK /LOCATES ID PENNON NAOE TO TM f1EE7 31 PLAN DIMENSION NOTES • ALL FIXTURE TO FIXTURE DIMENSIONS ARE TAKEN TO CENTERLRE (0f SAME) • ALL FIXTURE TO WALL AND /OR CEILING TRANSITION DMENSION8 ARE TAKEN FROM CENTERLINE OF FIXTURE TO FINISH FACE OF GYPSUM BOARD. • ALL LIGHT FIXTURES WHICH OCCUR N A 2' x 2' LAY4/ CEILING N THE BALES AREA ARE TO BE LOCATED N THE CEILING TILES PER DETAIL A, SHEET 3.0 UONTNO PLAN NOTES I. AFTER INSTALLATION. ELECTRICAL CONTRACTOR 15 TO TILT THE LAMP IN ALL PERIMETER ADJUSTABLE FIXTURES AT A 13' ANGLE TOWARD THE ADJACENT HALL DISPLAY CABINETS OR ANTICIPATED OWNER DISPLAY ITEMS 'TYPICAL ONLY ADJUSTABLE FIXTURES: INDICATED HTH AN A) 1 IP MUSIC SPEAKERS AND DIFFUSERS NEED TO BE RELOCATED OTHER THAN *050 15 NOWT ON LIGHTING PLAN THEN LOCATE AS CLOSE TO DVEN LOCATION AS POSSIBLE - RELOCATE IN A SYMMETRICAL PATTERN M RELATIONSIR TO AOIA- CENT LIGHTS AND SPRINKLER HEADS 3. WHEN INSTALLING LIGHT TRACS. USE MAXIMUM LENGTHS WIN AS FED 'SPLICES AS POSSIBLE. APPROXIMATE HEIGHT UNDER STEEL: NO APPROXIMATE HEIGHT UNDER DECK: SURVEY MA. EMI INIUN®®®® Irdi MI El INISSIMEM Ili MEM �iiP?Ii�N ®® 10 - s ®® INIESIEIMIN 1 UM El III 1 ® ©: Ell : ®:....... IIIIIMEEMIN ENE 11110E11111111111111 . mom MI ME MI • 1 EQUAL SPAC'E� ` ® ® � © ®' �• �© m ®� ® ®® � O OUND CABINET (BELOW UTILITY /TELEPHONE PANELS C OP SINK BLOW 5 SPACES .• 2' -6' 12' -6' 5 SPA a 2'-6': - 12' -6' -5.1/4 CEILING MOUNTED PENDANT FIXTURE. 1TYPICAL OF 5} I' -5 1/1' ' -10 1/2' 2'-11 1/2' SPACESS • 2' -6' - 32' -6' LAVATORY 'LOCATE DASHED LINE FIXTURES ON /IN GYPSUM BOARD CEILING' ?J1hO j ELECTRICAL FIXTURE SCHEDULE SYMBOL DESCRIPTION RECESSED DO NNLIGHT P ENDANT LIGHT CEILING MOUNTED) BILLBOARD LIGHT (SOFFIT MOUNTED AT TRANSITION AREA) RECESSED ADJUSTABLE DONNLWHT P ENDANT. LIGHT 'CEILING MOUNTED AT DEMONSTRATION AREA1 PENDANT LIGHT (CEILING MOUNTED) SPECIAL BILLBOARD LIGHT (SOFFIT MOUNTED AT STOREFRONT) TRAC LIGHT NHITE SYMBOL = DESCRIPTION SPEAKER SINGLE TUBE FLUOR. FIXTURE FOR NON - SALES 40' LONG EXIT SIGN SALES AREA EXIT SIGN NON -SALES AREA EXIT /EMERGENCY LIGHT NON-SALES AREA EMERGENCY LIGHT SALES AREA EMERGENCY LIGHT NON -SALES AREA MECHANICAL FIXTURE SCHEDULE SUPPLY AND/OR RETURN DIFFUSER MEFER TO MECHANICAL PLAN) 111 �N© O O OILY O ©O N.: © r r■ s II --y T PICA( CEILING MOUNTED PENDANT FIXTURES. SEE DETAIL C /2.2. 200 HEIGHT 'TYPICAL). 4 SPACES 5 2' -6 arv APR 2 N I995 PERMIT CENTER 4 SPA • 2' -)' • 10' -0• 1 -5 1/1' —CEILING MOUNTED PENDANT FIXTURE TYPICAL OF 3 (REFER. TO DIET. C /121 E0. r 1 1 I r 7 L JL__J r i t 7r 11 11 11 12) 3' THIN TUBE STAGGERED 11 11 FLUORESCENT FIXTURES II I 11 11 11 L__JL JL 151 4' 195 TUBE STAGGERED FLUORESCENT FIXTURES BACKWRAP LIGHT BOX DETAIL n4=1 "6- INFORMATION AND REFER TO SHEET E0. NOTE COLOR OF MAC MATCHES COLOR OF TRAC -CITE ONE 'SCHEDULE THIS SHEET) LIGHTING PLAN SCALE: 1/1' = 1 -0• Bath & Body Works T HREE UNITED PARKWAY COLU116U5, 0100 13133 611 -479 -7000 w Is °v1• - ro• revised GC. TO LOCATE KEY OPERATO STATIONS IN THIS COLUMN ENCLOSURE NTH MOTOR THIS SIDE) - REFER TO STOREFRONT DETAILS C OP GRILLE OPENING LIGHTING PLAN 'SPEOAL BILLBOARD' FIXTURES: REFER REFER TO ELEVATION TO LOCATE G OF 3-BOX SOUTHCENTER MALL SEATTLE, WASHINGTON dale 1-X-16 OA 1 ASTERISK 500*1ES NO REVISION MADE TO 210 38551 slue( 3.2 0-1 1 0-5 1 ALL NON-SALES FLOORS (UNLESS NOTED OTHERWISE, ALL NON-SALES SHELVING (TYPICAL, ALL NON-SALES WALLS (TYPICAL, !OMENS II 611 1111111111r El I=M., WOO 111111MI) 0 11.1 LIZ Mit_ DMSB ENTRY FLOORING NOTE RAL CONTRACTOR 15 TO PROVIDE AND INSTALL " NG TO ATCH MALL FLOORING N *504 807U084 'EASE AND CENTERLINE OF GRILLE; CENTERLINE OF ' DOORS: OR CENTER OF SHOW WINDOW 5)11; , A 1 5 „ APTLItABLE. G.C. TO OBTAIN SPECIFICATIONS OF OR TYPE AND PATTERN FROM LANDLORD'S REPRESENTATIVE. NOTE TOP OF MALL FLOORING. NEW MALL FLOORING AND STORE FLOORING TO BE MADE PLUSH. DII CM°"A5PAN FOR SPECIFIC INSTALLATION IPATTERNI INSTRUcTIONS. REFER TO DETML P/1.2 T1ALL FLOORING SURPLUS MATERIALS NOTE ALL 'EXTRA FLOORING MATERIALS (SURPLUS OR OTHERWISE UNUSED, ARE TO BE NEATLY STACKED 05 THE DECK ABOVE THE MANAGER'S OFFICE AND/OR TOILET R00115, CONSULT OWNERS' CONSTRUCTION MANAGER REGARDING DISPOSITION - OF ANY OTHER EXTRA' OWNER SUPPLIED MATERIALS. rO1 Mr SALES AREA WALL BASE NOTE ALL BASE TRIVI ON SALES AREA WALLS PER DETAIL 0/01 UNLESS NOTED OTHERWISE. GENERAL CONTRACTOR 15 TO INSTALL (OWNER SUPPLIED) I/O THCK PREPINISHED PINE BASE ON ,ALL SALES AREA WALLS AND COLUMNS NOT COVERED BY DISPLAY CABNETS. SCRIBE BASE TO TOP OF FINISH FLOORING. G.C. WALLCOVERING NOTE: WALLCOVERING LAYOUT SHOULD BE / STARTED AtID WORKED HORIZONTALLY IN BOTH DIRECTONS FROM THIS POINT. ALL SEAMS MUST BE ACCOMPLISHED ALONG EDGE OF FULL CHECK - DO NOT CUT CHECK TO SEAM. E -1005 (FOR RIZONTAL & VERTICAL SEAMS/ SEAS! _s - s_ s_ _INCORRECT CONSULT OWNER'S CONSTRUCTION MANAGER FOR ANY ADDITIONAL INFORMATION c■T,POnignu APR 2 9 1996 PERMIT CENTEH SCALE. I/4' • rro• Bath & Body Works iHREE .100 PARKWAY COLUMBUS. OHIO 03210 614-479-700D revles0 STOREFRONT ELEVATION FLOOR AND WALL FINISH PLAN FOR CABINET SCHEDULE, FINISH SCHEDULE, AND PAINT NOTES: SEE SHEET 1.1 GENERAL FLOORING NOTE • WHEN TREATING OR CLEANING EACH FLOORGG. GENERAL CONTRACTOR 15 TO MASK OFF THE ADJACENT FLOOR FINISH FLOOR/WALL AND INTERIOR ELEVATION KEY NOTES • ALIGN PLOOR141151( CHANGE WITH BACK 5100 00 DOOR JAMB. • PREFINISHED CASHWRAP AND BACKWRAP COUNTERS PROVIDED BY OWNER. NSTALLED BY MIER. CONTINUE FLOOR 50150 UNDER Dom O PREFINISHED WALL DISPLAY CABINETS (TYPICAL% PROVIDED BY MIER. NSTALLED BY G.C.. REFER TO CABNET DETAIL SHEETS. • CONTNUE FLOOR FINISli UNDER CABINET BASE TRIM TO SUB-PLATFORK BEYOND (TYPICAL). REFER TO CABINET DETAIL SHEETS. GC TO SCRIBE BOTTOM EDGE OF ALL WALL AND CABINET BASE TRIM TIGHT TO TOP Of max FLOORNG ITTPCAL) O FACE OF WALL FULL HEIGHT / BASE 70 CF111114 O FACE OF WALL - AT WALL 0150140 CABINETS. O E *11 07005 LOCATIONS, FRI HEIGHT / P•SF TO OFF NA • FACE OF WALL . ABOVE INF OF ( VALANCE O ALIGN FLOOR FINISH CHANGE NTH FINITI FACE OF HEATHER BOARD SONG • PREFINISHED SOLID WOOD DOOR P5001000 50 OITNER. OISTALLED BY GC IRE,. TO DOOR SCHEDULE, HOLLOW METAL FRAME 15 TO BE PANTED P-6 OIL BASE MUSH 0 FACE OF SOFFIT • Z4,71: Jr t 15 , 113 , , , ,NDER CABINETS TO FACE 00 1801084 BOARD NONCE/ 0 :14:14L AR REFER TO 'PRESENTATION DETAIL' 0 HOLLOW METAL DOOR I FRAME. PANT SALES 1.00 05 DOOR I FRAME P-6 (PAINT NON-SALES SIDE OF DOOR I FRATIE P701 O G.C. TO LEVEL EXISTING FLOOR AT CASHIARAP/BACKWRAP AREA USING LATEX LEVELING COMPOUND. TAPER EDGES DONN TO 700 00 FLOOR SLAB nne PER Fa? MAXIMUM TAPER,. O FACE OF WALL • ABOVF UNE OF MED 548157 AREA 5 F F 0 FACE OP WALL 01. LINE OP mon 7405557 AREA FYN, FLOOR AND WALL FINISH PLAN SOUTHCENTER MALL SEATTLE, WASHINGTON "TA r-o. d.t. 4-11-16 AJL - AEO CT i .bat 4.1 ASTERISK IIRMOATEIS NO 800808 5005 505480 mmET EXISTING NEUTRAL PIER TO REMAIN EXISTING BALL BULKHEAD - 84358ELLA FIRE3IST MATERIAL AWNING BY OWNER -1 EXTBNOEO LEASE LINE BACK COUNTER SPLASH TOP REFER T L F/T.] P SPECIFIC INSTALLATION (PATTERN/ INSTRUCTIONS INDIVIDUAL R' 1.3URFACE MOUNTED NON -11. UMINATED WOOD LETTERS PROVIDED AND INSTALLED BY OWNER. r � � ����E���������� r Il� f �° ul !Ill E:`14911�iiIllli+ R ! III gin II OP E/ \ II / . JAKIIIIIIIIIM 1 M_ � 1 I BAC - 01H O O O . O O O. Y/ O O : J 7 4 71 41 7 JA I. 4 I 1 - 11 1 O O O y 4 1 -MALL BULKHEAD - SUNBRELLA FIRE50T MATERIAL AWNING BY OWNER NON- ILLUMINATED SIGNAGE BY OWNER LINE OF AWNING BEYOND TYP. SCALE I/1' • 7 -0' 3/4' PREFINI3HED'TEA- STAIN' PLANKING WITH DA00 EDGE ON GRILL COLUMN ENCLOSURE 452CIAL BILLBOARD' LIGHT FIXTURES ITN 'U' STYLE STEM EXISTING MALL BULKHEAD WITH MIRROR BAND BILLBOARD LIGHT FIXTURE REFER TO I QUA NT PLAN FOR TYPE 1 QUANTITY -i STOREFRONT ELEVATION AWNING BY 04NER 3/4' PREFINISHED'TEA- STAIN' PLANKING WITH °ADO EDGE EXISTING NEUTRAL PIER TO REMAIN z \GRILLS/ OPENING \ INTERIOR ELEVATIONS SCALE: V4 • I'-0' FOR CABINET SCHEDULE, FINISH SCHEDULE AND FAINT NOTES: SEE SHEET 3 G.C. WALLCOVERING NOTE: WALLCOVERIIO LAYOUT 8NDULD BE STARTED AND WORKED HORIZONTALLY IN BOTH DIRECTIONS FROM THIS POINT. ALL SEAMS MAT BE ACCOMPLISHED ALONG EDGE OF FULL CHECK - DO NOT CUT CHECK TO SEAM. SEAM / CORRECT (FOR HORIZONTAL & VERTICAL SEAMS) — INCORRECT CONSULT OWNER'S CONSTRUCTION MANAGER FOR ANY ADDITIONAL INFORMATION APR D 2 9 1906 PERMIT cENTUR FLOOR /WALL AND INTERIOR ELEVATION KEY NOTES OI ALIGN FLOOR HEISH CHANGE WITH BACK SIDE OF 0008 JAMB. O PREFINISNED CA. /WRAP AND BACKHRAP COUNTERS PROVIDED BY OWNER. INSTALLED BY OWNER. CONTINUE FLOOR FINISH UNDER BOTH. O PPEFINISHED WALL DISPLAY CABINETS (TYPICAL /. PROVOE) BY OIRIER. RISTALLED BY G.C. REFER TO CABINET DETAIL SHEETS. O CONTINUE FLOOR FINISH UNDER CABINET BASE TRIM TO SUB - PLATFORM BEYOND (TYPICAL/. REFER TO CABINET DETAIL SHEETS. G.C. TO SCRIBE BOTTOM EDGE OF ALL WALL AND CABINET BASE TRIM TIGHT TO TOP OF FINSH FLOORING (TYPICAL). 05 FACE OF WALL • PILL' HEIGHT / BASE TO 404ING © FACE OF WALL - AT WALL DISPLAY CABINETS: ABOV OF ALL OTHER LOCATIONS: F A•• T f w:W OT PACE OF WALL • ABOVE I INF 05 CABINET VALANCF O ALIGN FLOOR FINISH CHANGE NTH FINISH FACE OF WEATHER BOARD SIDING. 09 PREFINISHED SOLID WOOD DOOR PROVIDED BY OWNER. INSTALLED BY GC. (REFER TO DOOR SCHEDULE/ HOLLOW METAL FRAME 15 TO BE PAINTED P -6 OK BASE FINISH. LOO FACE OF SOFFIT O CONTINUE FLOORING U BO NDER CABINETS TO FACE OF WEATHER BOARD MOW GYPSUM WALL SOARO. O SPECIAL INSTALLATION INSTRUCTIONS - REFER TO 'PRESENTATION DEW, SHEETS FOR ADDTIONAL INFORMATION. 13 HOLLOW METAL DOOR 1 FRAME. PAINT SALES SIDE OF DOOR 1 FRAME P -6 (PAINT NON -SALES SIDE OF DOOR 1 FRAME 9-5.1 11 GC. TO LEVEL EXISTING FLOOR AT CASHWRAP /BACKWRAP AREA BUNG LATEX LEVELING COMPOUND. TAPER EDGES DOWN TO TOP OF FLOOR SLAB NB PER FOOT MAXIMUM TAPER/. LOS FACE OF 4A1.1 : ABLYE FACE OF WALL • BPI OW LINE OF FIXFD RAAKFT ARP* 56F10 Bath & Body Works THREE WAITED PARKWAY COLUNBUS, OHIO 47130 614 - 471 -7000 INTERIOR ELEVATIONS SOUTHCENTER MALL WASHINGTON SEATTLE, WASHINGTO Mimi 94R seals rOvised ASTERISK INDICATES NO REW1 . WOE TO TM MR 4.2 NEUTRAL PIER PAINT ON 3 5/8' METAL 5TUD5 BUTT ALL CORNERS (TYPICAL) LINE OF GRILLE OPENING ABOVE GUIDE 4 OP GRILLE — PROJECTION KEY OPERATOR STATIO5.'MOUNT ¢ AT 24 ARP - ' G :. TO PROVIDE ' COVER PLATE TO MATCH PREFINISHED 'TEA - STAIN' PINE PLANKING.' (TYPICAL OF 3) REPER TO CONSTRUCTION PLAN 1 /8' G 5/8' GYP: BO. OVER METAL FRAMING AS - . .1 REQUIRED (TYPICAL) FACE OF PINE PLANKING. TRIM ON STOREFRONT BULKHEAD (ABOVE): DESIGN CONTROL ZONE ROLL-EP GRILLE EMERGENCY RELEASE DEVICE INSTALL lo 3 A.F.F.G:C. TO PROVIDE COVER - PLATE TO MATCH 'TEA: STAIN PLANKING. ALL NEUTRAL ZONE EXISTING RATED DEMISING WALL NEUTRAL PIER PAINT P H 3/1' P855141SHE0 TEA STAINED PINE PLANKING .1 DA00: EDGE (SUPPLIED BY OWNER) REFER TO INSTALLATION NOTE '(PLANKING/' BELOW INSTALL OVER 3/1 PLY14000 EXISTING RATED DEMISING ALL 3/1' PREFINISHED TEA STAINED PINE PLANKING ./ DAD° EDGE (SUPPLED BY OWNER) REFER TO INSTALLATION NOTE %PLANKING,' BELOW INSTALL OVER 3/1 PLYWOOD MALL NEUTRAL ZONE EXTENDED LEASE LINE LINE OF SUNBRELLA FIRE518T AWNING PROVIDED I INSTALLED BY OWNER DESIGN CONTROL ZONE PLAN DETAIL SCALE I I /1' = I' -O' LEASE LINE PLAN DETAIL SCALE: I In = 1 -0' APR 2 91996 PEPAAIT CENTER Bath & . Body Works PUREE UWOED PARKWAY COLUMBUS, OHIO 13130 6)1 -178 -7000 GRILL O O ROLL JP GRILLE GUIDE GROOVE 40 PREFINISHED BLACK METAL OR PREFINISHED WOOD PLANKING IN CASE OF BLACK METAL TUCK ENDS OF BLACK METAL AT SIDE OF GRILLE GUDE (TYPICAL) KEEP TIGHT TO WIDE BLALK ANODIZED SUPPLIIED0NSTALLED BY OWNER INSTALL- MOUNTING BRACKETS ON FRONT SIDE OF POST (TOWARD NALL, NO %ALA CONCEAL GROOVE AND - MAINTAIN INDICATED DISTANCE PROM FACE OF BLACK METAL OR WOOD TO END OF GRILLE GUDE GRILLE GUIDE & SUPPORT POST DETAIL GRILLE SUPPORT. POST SUPPLIED/ INSTALLED BT OWNER O.C. NOTE: STATE AND/OR LOCAL CODES MAY REQUIRE THAT ALL WELDING OF STRUCTURAL STEEL BE ACCOMPLISHED UNDER THE SUPERVISION OF AN APPROVED ENGINEER AND /OR INSPECTOR. TIE GENERAL CONTRACTOR N RESPONSIBLE FOR THE ACTUAL VERIFICATION OF THIS REQUIREMENT AND THE COST OF SUCH SUPERVISION OR INSPECTION MEN REQUIRED. INSTALLATION NOTE: (PLANKING): POSITION PLANING ON EACH INDIVIDUAL WALL SO THAT FIRST AND LAST PIECES ARE EQUAL 88 WIDTH. UTILIZE LARGEST AVAILABLE DNENBION PINE PLANKS ARE MANUFACTURED IN VARIOUS LENGTHS - G.C. TO STAGGER SEAMS IN A RANDOM PATTERN. ITYP. AT EACH WALL) ^ S NT / 050 T STOREFRONT DETAILS SOUTHCENTER MALL uTe SEATTLE, WASHINGTON .eels I #-% dots ICr.wn la . 7-0' 4 AA revised MAW 5.1 • ASTERISK INDICATES MO REVISION MADE TO 8MB MEET SECURE TO STRUCTURE' ABOVE MOT TO DECK/ 3 5/e' x 30 GA. METAL STUDS FRAMING 1 16' O.C. G.C. TO INSTALL ID LAYER OP 5/8' TYPE 'X' GYP. BOARD ON BACK SIDE OF MALL BULKHEAD. RUN TIGHT TO DECK ABOVE IF REQUIRED AND NOT ALREADY EXISTING. 1001. ACROSS ENTIRE STOREFRONTI. ROLLING GRILLE SUPPLIED AND INSTALLED BY OWNER 3 6/8' x 20 GA MTL. STUD • FRAMING • 16' 00. CONTINUE 'TEA STAIN' ON ENCLOSURE 10500901 UP TO THIS POINT 101 0 • 14 GAUGE MTL. 601615 WELDED TOGETHER - SECURE • ENDS TO GRILLE. POST Y -0' AKE 5/8" GYP BOARD PAINT I=1 LIGHT FIXTURE AND TRACK- REFER TO LIGHTING PLAN FOR TYPE AND QUANTITY PAINT THESE VERTICAL GYP. 50 SURFACES ONLY I=1 CL OF GRILLE PREFINISHEO METAL PLATE SUPPLIED • I INSTALLED BY GRILLE MANUFACTURER G C. TO PAINT TO MATCH CEILING LINE OF GRILLE COLUMN ENCLOSURE I11E002101 TENANT FLOORING V2' 63/ TO •MATCH MALL FLOORING SECTION SCALE IVT •1 -0' • EXISTING MALL CONSTRUCTION GC TO PROVIDE MIRROR BAND IF NOT EXISTING COORDINATE WITH LANDLORD 3 /8'x 3/8' BLACK 1' CHANNEL REVEAL MALL FLOORING 12' - A F.F. 00 ALL NEUTRAL ZONE PAINT 3/1' PR50315950 TEA STAINED PINE PLANKING 5/ DODO EDGE ON 3/4' PLYWOOD 10.0 TO USE SINGLE LENGTH PLANKING AT THIS AREA NQI RANDOM LENGTHS) 'SPECIAL BILLBOARD' LIGHT - FIXTURE - REFER REFER TO LIGHTING PLAN FOR TYPE AND QUANTITY ENRAGE EY OWNER 5/8' GYP.. BD. LIGHT FIXTURE AND TRACK- REFER TO LIGHTING PLAN FOR TYPE AND DUANTITY 'EXTENDED LEASE LINE LEASE LINE N' -0' AF.F... - LINE OF SUNBRELLA PIRESIBT MATERIAL AWNING. SUPPLIED I INSTALLED BY OWNER APR 1996 PERMIT Bath & Body Works THREE UNITED 9000101 COLUMBUS, 0x10 43930 614 - 419 -100D O.C. NOTE: HEIGHT OF GRILLE STOPS M THE OPEN CONDITION RUST BE VERIFIED AGAINST THE HEIGHT OF THE SOFFIT CONSTRUCTION BEEQBE FRAMING BEGINS 1 GRILLE PLATE MUST CLOSE FLUSH WITH THE BOTTOM OF THE FMBHED SOFFIT. PROTECTIVE PAPER MUST 8E REMOVED FROM LEXAN INSERTS ON UPPER PORTION OF GRILLE CURTAIN BEFORE HOUSING IS ENCLOSED WITHIN CEILING 0.C. NOTE: STATE AND /OR LOCAL CODES MAY REQUIRE THAT ALL WELDING OF STRUCTURAL STEEL BE ACCOLPLMHED UNDER THE SUPERVISION OF AN APPROVED SEMEN AND /0R INSPECTOR. TIE GENERAL CONTRACTOR IS RESPONSIBLE FOR TIE ACTUAL VERIFICATION OF TINS REOMREHENT. AND TIE COST OF SUCH SUPERVISION OR INSPECTION WHEN REONRED. STOREFRONT DETAILS SOUTHCENTER MALL b� SEATTLE, WASHINGTON — ' .0.5. 02' 1 4.LF I*855 I ' . 1 - 4 -15-16 AA r.N..O TEPEO 07 416;1 • 98TERIBR RDICATEI NO REVMIO8 WOE TO 0•8 BURET 5.2 M - W _ SMOOTH I 1 r { , I 6/8' TYPE X' GYPSUM -. ARD OVER METAL FRAME TEA STAIN PI PLANKING OVER 3/1' FIRE R ARDANT TREATED PLYWOOD REFER t• STOREFRONT I I•• <— TEA STAIN R PLAN T KING OVER 3/1' fIRE RETADAN TREATED PLYWOOD ,' ' + + + - 1 - } + + III TYPE BD REFER TO STOREFRONT SECTIONS SHEET E] 1 I/1' x 3/4' TOP SOFFIT PINE TRIM STAIN PINE PLANKING I 538' TYPE 14 BOARD ', i1 X' YP OVER MET FRAMING OVER YP CAL) TEA 8 AIN PLANKING OVER f 11 OVER METAL FRAMING - TEA 6TAIX PINE PLANKING OVER + -1- } + VERTICA GYP A RILLE OPEOPENING AND PAST AT OVERHE P Z I 5/9' TYPE 'X' GYP. BD. OVER 'METAL FRAMING I III 11A ■ b- TIONS SHEET 62 $ 6 /e'. T X' GYPSUM BOARD OVER METAL FRAMING FIREbIbT MATERIAL ANNMG AND FRAMING PROVIDED ND / % METALLED BY OWNER. TE. NO EEt REFER TO STOREP T RAM1NG SECTIONS, FOR META ( 3/1' RE RETARDANT T - 'ATM PLYWOOD ITYPICALI /B' PLYWOOD RETARDANT TREATED- REFER TO STORE STOREFRONT ".. x -. 131 E GAUGE JOISTS WELDED TOGETHER SECURE • ENDS GRILLE POST . gN3' MTL TO - i. ILL4 1'I II I I I I31 B' x H GAUGE METAL JOISTS MEL TOGETHER 1x WOOD BLOCKING A9 REQUIRED (/E' {II rc :: I:IE �'I�II I 1'• 1 REFE TO6TOREFRONT� SECT ONB SHEET 61 5/1' BOTTOM SOFFIT TEA ` AIN PINE TRIM ■ SECTIONS SHEET 6] FlREbIbT MATERIAL ANNM4 AND FRAMING . 'INSTALLED BY OWNEIRED XD TEA OVER 3N' FIRE RETARDANT TREATED PLYWOOD /B' TYPE IX GYPSUM BOARD 1 1 r 3 /1 6 I/1' E STOE5 VER METAL FRAMING TO STOREFRONT SECTIONS, CUT TO PIT NOTE. REFER TO STOREFRONT SECTIONS. al 5.1 FOR METAL LE FRAMING O OT HERWISE SPACING, UNLESS NOTED � 031296 53 FOR METAL FRAMING AND SPACIN G; UNLESS NOTED OTHERWISE - HEAD DETAIL SHEET 5.2, FOR METAL MING OTHERWISE SPACING, UNLE' = NOTED SIZES AND TRIM DETAIL ETAIL TRIM ,DETAIL- 5. RASING SPACING. UNL • AM SPACING. NOTED • IES A 2 OTHERWISE TRIM DETAIL Q - HMLLE ROLLING HEAD DETAIL - - 072595 0125 072595 - 0725 DETAIL � DETAIL B •3 DETAIL C•3 DETAIL •3 5.3 FIRESIbT MATERIAL AWNING PROVIDED AND INSTALLED Y . (RESIST MATERIAL AWNING - 001090 AND INSTALLED B OWNER. \ YP OVER TYPE X • GYPSUM BOARD OVER METAL FRAMING CON COUB CHANNEL - GCTO A- ICATEPROM 18 GAGE 6. ET METAL )(RESIST MATERIAL AWNING 5 /8',x 6' FIRE TREATED , PROVIDED AND INSTALLED BY OWNER STAIN' OWNER P - 5 0 BOTH G E PINE 03129. ■ _ --� Al 6/ • TYPE'X' GYPSUM BOARD •'ER METAL FRAMING (TYP.1 • Z L �, I di b - _ E—( 1/1 PINE ' TRI x 3/1' OP SOFFIT TEA -STAN PINE PLANKING - 2x FIRE RETARDANT TREATED BLOCKING 1 6 /8' WE 'X' GYPSUM BOARD OV R METAL FRAMING TEA -STAN PNE OVER 3/1' FIRE RETARDANT TREATED PLYWOOD PLANKING ' V B' OVER 3/1' PRE RETARDANT TREATED PLYWOOD W000, BLOCKING R EFER t0 STOREFRONT � SCONS SHEET 53 ,` X / '• 3/1' PREFINIbHED'TEA PINE '. INSTALLE PROVIDED BD BY G.C. -RI INSTALLEI DOWN TO FIT ■ I WOOD ' •A t 5 /8' x 5 I/3' FIRE TREATED OOD BLOCKING 1 � � • ® � - PROVIDED R AND INSTALLED BY OWNER. REFER TO STOREFRONT SECTIONS SWEET 61 \ 3 1 WO- L EFRT NSOT P 2 BEFORE Gl 4 1 / B' x 5" FIRE TREATED OD 9lBLOCKING 4 Ii! , _ _ I / /JI TRACK WITH FIXTURE y /1' TEA STAIN PINE y� ^ I, 3 I/2' RONT � � SECTN)N5 SHE x YDE GLAZING SLOT -PAIN? BEFORE GLAZING ®S 3/1' BEFOR OF SLOT P -] GC. TO TAPE AND CAULK BOTH SIDES OF GLASS D CA ON 00S BEAD OF GE 50 - RUH SILICONE (COLOR TO TCH TEA STAIN PINE PLAN- 0 yDaD; REFER TO STOREFRONT 5 TON HEET 51. S =_AL PRAM SI AN FOk D SP ACNG T . UN LESS N ED OTHERWISE TRACK WITH FIXTURE II /1 TEA STAIN PINE TRM.'PELD CUT BY GC. EDGE TO FACE GLASS , ' T b I I • � I 3/1' OVER BOARD \ - ��i + L3/1" ` 5 1 /1' - ®— I✓/ -�� ®rte 4. �1N �E� � \ _ REFER T O STOREFRONT SECTIONS SHEE 5.3 �� CUT CU BY GC.. /1' TEA T PI ir BEFORE AZING / WIDE T ONT G — 3/4 GLAZING SE OHS INTERIOR 1 fOS6 G TO C ANO CAULK SIDE OF G LASS US COATI OUS BEAD c SILPRUF LICONE - (COLOR TO NAM TEA STAIN PLANKING( R EFER TO STOREFRONT SEC •55, SHEET 62. FOR METAL FRAMING HEAD DETAIL SIZES AND SPACING UNLESS NOT OTHERWISE STOREFRONT GLASS - EPEE TO STOREFRONT 8'= I WHET 52. PORT KNEES HEAD DETAIL 11 REFER SHEET SIZES GC TO TAPE A CAULK BOTH SIDES - OP GLA55 G CONTINUOUS BEAD GE. SILPRUf' SILICONE - O LOR TO MATCH TEA STAIN' E PLANKING) R TO STOREFRONT SECTIONS. 5.2 FOR METAL FRAMING AND SPACING, UNLESS NOTED 'EFRONT GLASS - GL TO TAP- AND C AULK BOTH S IDES OF GLA - U L ONT NUOUS SEA OP GE 'HUMP' SILICONE (COLOR TO MATCH TEA STA PINE PLANKING) REF R TO STOREFRONT SECT(035, SHEET 52. FOR METAL FRAMING SIZES AND SPACING. UNLESS NOTED 500' FRONT GLASS - REFER II TO S TOREFRONT SECTIONS. ET 51, FOR THICKNESS HEAD DETAIL ST'- REFER STOREFRONT SECTIONS. W HET 5.2, FOR THCKNESS SECTION 3" = I' - 0" 03129 3' • - 0" 3 I' - O' OTHERWISE 03129. 3' _ ('_O• OTHERWISE 03189. DETAIL F 5.3 DETAIL G,3 DETAIL H 5.3 DETAIL 5.3 - -REFER - TYPE GYPSUM BOARD '1r p''911 E,,�5 6H T 6 P +' ( -J D EM4 � • BUI MIN. 1 114 c 1 cmpof A 9 APR R 9 `•, STOREFRONT GLASS TO 'STOREFRONT SECTIONS' OF THIS SET, FOR THICKNESS 1 BLA NEOPRENE GLAZING GASKET -' CH 0106. y TEA-STAIN PINE PLANKING OVER 3/1" FIRE RETARDANT MATED PLYWOOD 'X' - 51• GHT _rF� 'Z - -} I I I - MALL SIDE 5/e' � w ill B/8 TYPE GYPSUM BOARD OVER METAL FRAMING TEA -STAIN SCRIBE PREFINISHED KAWNEER BASE D 1 IN 11 .00 OR A - OVED (WISH. MA DE ERM 6 21 IBLC INSTALL PER MANUFACTURERS RECOMMENDATIONS (SEE SPECS, TENANT SIDE - = N— I t. . TEA STAN FINE RETAKING /TRIM 1` OVER 3/1 FIRE RETARDANT / • I I WOOD BASE - FINISH FLOOR J� '211 TO 'F AN WA FINISH PLAN' OF THIS 5 ' FOR FLOORING MATE' LS AND TRANSITION • AILS _ TREATED PLYWOOD 3/1" x PREFI "EO __ • I 1-•�_ BLACK ME SETAE : AL AO JA T CONSTRUCTION REFER • TOREFRONT PLAN DETA - SECTIONS THIS BET RIM JAMB - JAMB SHOWN. MAD 51MLLAR REVEAL DETAIL P'Ty FINISH R •ORI 2 Bath &Bo W 11 o i1 A7 W orks THREE ED PARKWAY COLUMBUS, OHIO 03230 61 -09 -7000 STOREFRONT DETAILS T (( F R TO STOREFRONT SECTIONS. SHEET 53. FOR METAL FRAMING SIZES AND BASE DETAIL OTHERWISE SPACING. UNLE55 NOTED D RA E SOUTHCENTER MALL BASE DETAIL SEATTLE, WASHINGTON .n..1 072: NOTED IEa0e 4 -11-16 G.vm MO �.� B -O' 010.' 010985 reMFed DETAIL � • - DETAIL . . 5.3 . '. DETAIL " 5 . •" ' / /, I 1 BASE CABINET 30' WIDE x DEEP I, �I! i ��' ..YN ... I �. - � � , �� .0 i� . , ( I J. VALANCE C TO N07CH LANCE ASSEMBLY A ALL A6 PLCCABLE)REQb - y l � , �I r I I II'�® L. TO NOT qLL IF READ CH L ANCE ASSEMBLY IIF '" PLICABLE) �, :c / 4 . �n U II .11 F I l ... , ' `` I iii,, iii,, iii,, A �� �� �� 1 - ' II �I / / UPRIGHT (VARIES) � ' IF USED HITH END PANE TT . OR ADJACENT TO AN • CABINET: UPRIGHT H ' 1 A HALF -WIDTH BOTT.M LEG IF USED ADJACE TO ANOTHER •S' MET UPRIGHT HAS FULL - WIDTH BOTT • LEG EN SHELVES ( - ER UNIT) EACH ELF BRACKETS / 2 1 6 RACKETS D END �{ Iii CLIPED ORNER VALANCE (S P DETAIL C A/S 21 /`` I ` I I R I I � �. I) I I i / / 1 I INSIDE CORNER J ` �� ' -. �� `I'II �\` \ 1 Y , .. \/ �� OUTSIDE CORNER MI ALL PONENTS AT 15• EE DETAIL A /61 I � rr G �I �,� �,' ® I,�I �I ALLOW EXTENDED III �� END SHELVES IA PER UNIT) EACH BNELF REQUIRES 111 SHORT BRACKETS UP R IGHT _ CORNE ���I _ . 1" I ,® � I P '* 1\, \ , I/1 POLISHED PLATE VINYL BACKED 'SAFETY' MIRROR - PROVIDED AND � INSTALLED BY GC. OUTSIDE R® — ����� N \� / / \ d / �� 1P �A � � I \ rr er , � CORNER SHELVES ® NO MRROR) ' ' / ! < ' ASSEMBLED '. \/ \� \/ rir VIEW I / , , 0 i � "R" CABINET / / DEEP END (1 ] � C ABINET P R E BASE CWOEETI9 N/ III FINISHED EXTENDED PE R.UNIT) RUNIT) EACX 4 REGU L AR BRACKETS _. HAD - FINISHED END /N' OB END / DE S 11 PE EACH SH L P REQUPER UIREUNIT) EACH SNELI UPRIGHT I INSIDE CORNER SHELVES (X PER UNIT) EACH 6NELR REQUIRES I yIHYL P BACKED 4APETY' MIRROR - PROVIDED AND INSTALLED BY GC \ 1 '�' CENTER 14 PER 0 SH ELF - 111 BRACREKETS �I ® POP ,' .. SHELVES UNIT) EACH QURED S HELV ES IAS SHOWN) O E XTENDED END OR )SEE B ELOW) -OUT CENTER SHELVES )SEE BELONI SHELVES 'AS SHOWN) 111 ORANER6 NTHIN IZ) SHELVE. WITHIN 111 SHELVES WITHIN I , - , , \ , \ - ASSEMBLED � �� , , ' - I,I � VIEW / "S" .�� • / 111 � Y_ I / �/ - � CABINET / ` / BA BASE 80' N/ 12) REGULAR BRACKETS 1 -SIDED END END PANEL \ CABINET WIDE x ED EN DEEP UNFINISHED ENDD PANEL i / \ 1 111,........--...--.- ' ,\ (3I BRACKETS �/ I� HI PER IN PER UNIT) l RA SHELF REQUIRES BRACKETS O '7,,, / to ar 41 ii � , I \ �I W NFINISH ED ENDS so. N CABINET HO DEx 26' DEEP. ' / UNFINISHED ENDS SW CABINET W 30' WOE x D' DEEP, UNFINISHED ENDS N/ U '. ASSEMBLED, 11 I ®' ... I VIEW "L , "M" & 'T" / © ® O CABINETS BASE CABINET • DEEP NRINIfiHED N DS ` � \ ASSEMBLED VIEW ''P" CABINET -- BASE CABINET W U ENDS ASSEMBLED � DEEP &I 1, \ �� I,'I�I'I, VIEW "N" CABINET. I ♦� � �' *%.' ),,I ' - 'N O T TO SCALE 04130 29 - - NOT TO SCALE 03129 NOT TO SCALE 031296 NOT TO SCALE 081290 NOT TO SCALE 03129. DETAIL 8.1 DETAIL B 8.1 DETAIL 8.1 DETAIL' D 8.1 DETAIL 1 / DOUBLE -SIDED . OP VALANCE CA ALL GENERAL NOTES L NM 88800 0 ARE Pew F1RF4® VI MIR FOR ny. Rw® 0 we yeR RV FR.. pa8n cm / /II TOP VALANCE CAP ENDLABINET) ENDED SHELF R - SHOWN VALANCE COMPONENTS WITH EXCEPTION OF NOTCHED BOTTOM CAP ARE %• LONG AND COME IN BOTH OPEN -END' AND •FINISHED END STYLES (CUT TO LENGTH ON SITE, NOTCHED OTTOM VALANCE OT B CAPS COME 60 LONG IN 'OPEN-END OPD STYLE AND 3N I/1' I. , % ' VALANCE PANELS VALANCE PANEL NOT E VALANCE COMPONENTS CABINET MIRRORS MN MIN Al APPROOUrt Sate FOR �� uCx •001501C E�tF Y�Q!<GF or. me Fall O r OMIT" BR GCNI VA' a 37 Ur a p B0• ® (1 EWE VI' a 17 B/A' a p ! /!' a It EACM VA' • S' a p 6/IB' : O FA CM VA' • O 1NP p A /MP IH Nor AMI/MOMS ® 1.1 OPEN 00 MIRROR, MIRROR, S NI OM BD 108081 O II [ACM) VA' a 27 >/Y a p BVIY pPROMO fMFIe'0 eW , REMOVABLE ARE SHIPPED 98' IN L SIGNAGE PANEL LOON CUT TO LENGTH ON SITE C MOUNTING. INTERMEDIATE VALANCE CAP 'I ' LONG IN •FINISHED -END' MO CIITTIXG REQUIRED, MITRE ENDS) REMOVABL 914NAGE BOTTOM VALANCE CAP j � )ND PANEL OF APPLICABLE) E UPRIGHT T 1 GH R' CABINET) BOTH W iV BOTTOM LE4 ` INTERMEDIATE VALANCE CAP 1'FINISHED,END' CLEAT BY GC B Y - \ UPRIGHTS / . I• �\1 )III 1 , II, \ d ' L/H OPPOSITE \ I � SHALLOW SHELF SHOWN) END /CENTER UPRIGHTS BRACKET ITYP) IS' CABINETS) EOTTOM VARIES -SEE DETAIL THIS SHEET NOTCHED VALANCCAP NIBHED ENS' � s9oSNOW ` HELF BRA KE C P OF ALC 1I \ I I�, !1111 1 � � 1 /x FDUSXED FLaTe VINYL BACKED 'SAFETY' MRROR - PROY DED NSTALLED B(TYP.) `ETS)O AND SHELF BRACKET ITT!. OF ALL CABINETS) ��STRAIGHT SHAL SHELF BRACKET ' `\ ` BHALLON EXTENDED SHELF BRA ' CAB) ETS) \ CEN; / ER SNELP "T' CABINETS) CORNER UPRIGHT ITYP. R /X- OPPOSITE SHELF BRACKET ITYP OF ALL FIT ALL RETURN ] TRIM PIECE COMPONENTS FOR ROUTED MIRROR INSET G�� O pppF ,,,AK END UPRIGHT BELOW CABINETS) i .I II` 1 1 �� ) 6i NO SHELF IB'RHCA5HO X .! ® L/H OPPOSITE fr BASE TRIM ' ♦ 0 SE ITYP 'L CBINET ".'M P 'T'1 T DED D SHELF ' CAENBINE H -SHOWN - OPPOSITE � �� \ 1 I �-/ I ` `� ` ` x SUPPORT PLATfORM : I BA C, BNET R' /1 WDE x ]9 I/4' DEEP W END FINISHED) L/H - OPPOEND 1 S W /NO FI NED) END UPRIGHT r DETAIL 22 VALANCE RETURN END CAP TO BE CUT FROM VLAN PREINISXEO 5 BOTTOM VALANCE EcEiwUU AP 2 9 1996 R ]-SIDED 11 USEABLE HOLD EDGE PARTS � / I� 3 SUPPORT PLATFORM BY GC. BY G.0 . ` � I ; PARTS DESCRIPTION BASE TRIM ITYP)' %' LONG -CUT TO LENGTH ON bITE I'R' CABINET: MITRE END) 1's' CABINET: BUTT TIGHT TO END PANEL) I (TYPICAL) ALL FREE- STANDING CABINETS pSO ( RP p CURER H1 C .L • 1 ` 031206 END PANEL T+' 1 'T• CABINETS) BOTH SIDES FLUSH dFkoxT OF CABINET DESCRIPTION (TYPICAL) BASE TRIM ITYP. CABINETS) %' LONG CUT TO LENGTH ON SITE ALL WALL CABINETS u l,n � ♦ DETAIL \SP f f 1 � Bath & Bod �^7�[� WO rIl s THREE LIMITED PARKwAT COLUNBUS. 0010 13130 611-1)9 -)000 DETAILS OF L, M, N. P, R, 8 & T CAB. SOUTHCENTER MALL SEATTLE, WASHINGTON .9221 B0A8 NOTED I0i1i 4A (018 RDO 6.1 (REFER TO INDIVIDUAL ASSEMBLED VIEWS FOR BPECRK: I NFORMATION) NOT TO SCALE 03 2 - )REFER TO INDIVIDUAL ASSEMBLED VIEWS FOR SPECIFIC INFORMATION) NOT TO SCALE 031298 DETAIL 8.1 DETAIL G 6 /ROW • m • ASTERISK INDICATES NO RENNIN AIAOE TO MS MEET co o VALANCE IA60VE1 SEE DTL.. CABINET 0120 -PANEL - NOLO FLUSH TO FRONT • 'EDGE OP CABNNE GAT END PRIOHT YL /N MIRROR ITVP) STRAIGHT CENTER SHELVES REGULAR, 3/4 SHELVEB CABINET END CENTER PANEL - HOLD FLUSH TO FRONT UPRIGHT EDGE OP CABINET CABINET 3/4' HOOD PURRI FLAT END UPRIGHT. IL /W I/O " X 2I/2" PLAT CENTER ,UPRIGHT UPRIGHT UPRIGHT 30 Q CABINET OL CABINET END TRIM PIECE RETURN VALANCE (ABOVE) SEE DTL RUN VALANCE (ABOVE/ TIGHT TO GYP. BD. RO0 ITYP. 3/4 • HOOD W RRIN FLAT OUTSIDE • CORNER UPRIGHT 3/1" WOOD FURRING ROTE ITYP �1 E %TENDED END SHELVES IL /0) UPRIGHT 30" OL CABINET FLAT INSIDE FLAT NOTCHED" FLAT FLAT CORNER CENTER UPRIGHT SHORT' SHORT' UPRIGHT UPRIGHT IL /H) UPRIGHT • UPRIGHT OUTSIDE CORNER bNELVES UPRIGHT 23 3/1 O CABINET /4 • W5 . 0066100 MIRROR ITYP.1 /4 • STRAIGHT CENTER SHELVES INSIDE CORNER SHELVES UPRIGHT CABINET 0 O/7 /4 • le. FURRIN IE UPRIGHT PRE - FINISHED % PRE-FINISHED HOOD PANEL WOOD' -PANEL .FACE OF TOP — — VALANCE CAP - (ABOVE) FINISHED PACE CONTINUOUS -3/4 • HOOP OF GYP. BOARD HORIZONTAL FURRING WALL (SEE SECTION LINE OF MIRROR SLOT. IN BASE CABINET BELOW AND VALANCE CAP ABOVE FLAT INSIDE CORNER UPRIGHT ® 0NMr 011.0 BACKHRAP COUNTER BACKHRAP COUNTER COMES ALSO IN 60' LENGTH - AND UTILIZES ONLY ONE SHORT UPRIGHT CENTERED ON COUNTER. UNFINISHED PACE OF UPRIGHT PRE- FINISHED N000 PANEL FLAT NOTCHED" UPRIGHT (R /H) PL OF UPRIGHT TO ALIGN MTH BUTT JOINT OP. BASE CABINETS: ITYP) - IRROR ITYP./ STRAIGT H CENTER SHELVES UPRIGHT 30 - <> CABINET SCALE: r - I' -0• FACTORY 0000080 . INSTALLED SET IN MA S T IO STANDARDS AND BUTT -TIGHT (TTP) TO STANDARD AT, 2 -SIDED CORNER UPRIGHT IR /H). UPRIGHT . UPRIGHT 30" O CABINET O CABINET DEEP STRAIGHT CENTER SHELVES ' 2 -SIDED END UPRIGHT IR /111 HOLD UNFINISHED END- OF CABINET TIGHT TO OS CABINET FACE, OF GYP. BOARD TYPE MD OR 'S' CABINET/ SHALL. STRAIGHT CENTER SHALCOU EXTENDED .END UPRIGHT CENTER SHELVES UPRIGHT 'END SHELVES I13/0) (R /H) OPEN 010 MIRROR) 4.. DEEP EXTENDED /ND SHELVES (8/10 UPRIGHT A -I DETAILED INSTALLATION PLAN - L, M, N, P, R; S & T CABINETS SECURE UPRIGHTS THRU MOUNTING LEG TO SIDE WALL Of BASE CABINET , BELOW ITYP.'OPEN' CABINETS 09101 CABINET END PANEL FLAT END UPRIGHT VERTICAL CORNER FILLER ROPER TO DETAIL' B: THIS SHEET V • 2 V2' END TRIM P00 RUN FROM FINISHED FLOOR TO BOTTOM OF VALANCE ABOVE (SAME APPLIED TO CORNER FILM X96 -oii�l FLAT OUTSIDE CORNER UPRIGHT 0.01 HMMN : N0 0820858) ® ® ®1> 09REET8 ® comer Otto A -2 DETAILED INSTALLATION PLAN - L, M, N, P, R, S & T CABINETS 8 2 HALF. SIZE FILLER - RIP DONN FROM SCRAP 'TEA STAIN' PINE BOARDS FACE OF FINISHED WALL RUN FILLER HORIZONTALLY I/O ' BELOW TOP Of CABINET BASE UNIT FACE OF — NISHED WALL CABINET FILLER DETAIL DETAIL CABINET UPRIGHT BASE UNIT 10ELON) END PANEL (BELOW 033105 B 3.2 FLAT CENTER UPRIGHT .(D TGAP.OP VALANCE, TES 641800)0N 11080.50 r HELD TO ALLOW FOR ONNE OUPPLIE0 51GNAGE DETAIL ()CONTINUOUS (ABRDGM f 3 '. (APPROX. 30" O.CI 2 - SIDED CORNER UPRIGHT ALL BY GL. SECTION THRU "L" & "M" CABINETS DETAIL 031206 6.2 2 - SIDED CENTER- UPRIGHT GAMETE I 1 1 1 �, Ar DOUBLE SIDED TOP VALANCE CAP - - � ` y ® VALANCE PANEL REMOVABLE SIGNAGE PANEL DOUBLE SIDED a Q VALA N CE CA VALANCE CAP EN MI RROR/ ® DEEP SHEL 11 PER UNIT SHELF BRACKET 13 PER UNIT', O2 BASE CABNET DETAIL FRONT FACE r O6 3 SIDED UPRIGHT -- (BEYOND/ FRONT / REAR AND TOP OF CABINET MUST PIT PLUSH TO. AND ALIGN WITH. THE ADJACENT 0050000 1TTP) 2 - SIDED END UPRIGHT I8M L/N 00008181 ® GAMETE —THIS DIMENSION MUST BE HELD TO ALLOW FOR OWNER SUPPLIED SIGNA0E. MOUNTING LEG OF UPRIGHT (SECURE TO SIDE OF BA E CABNET AS APPLICABLE CONTINUOUS SUPPORT PLATFORM W/ BRIDGING (APPROX. 30" D.L.) ALL BY G.C. ECTION THRU "R" & "S" CABINETS 11/2' • 1-0" 031266 D oa SHALLOW CENTER 0001/35 PRE - PMISHED END OF VALANCE /ABOVE) 000 CENTER SHELVES CABINET END PANEL PRE - FINISHED END OF VALANCE /ABOVE) ENO CABINET PREFABRICATED INTERIOR 6800 (APPROX. 30' OC./ VALANCE PAN � REMOVABLE 81GNAGE P EL 00001E = 1DE0 PRE N. TONED BOT'•M VALANCE SHALLOW SHELF H PER UNIT) � 9HALLON SHELF BRACKET 12 PER SHELF/ REAR FACE 2 SIDED UPRIGHT /BEYOND/ SCRIBE BASE TR TIGHT TO TOP Of FINISHED FLOOR 033185 8.2 Bath & Body Works THREE LEITE/ P0NWAY COLUMBUS. OHIO 43230 614- I79 -700> CABINET ASSEMBLY NOTES ENiIALLATION INSTRUCTIONS IL M. N P & T CABINETS/ RR 6000 FRAM 1141.. 01 Ns s®1 GOALE18E MME 89 w A 0 1 TEARUIe M6N err FROM TNT LM MD wueRn rRaeen 1 - CRIER• ME1Dx MARL • 0 14174 046 ,“6.111170 ATM v .1.0.11 MNIN1 llO MARK AND A R AND TO TO PLO. l FROM Of MM. ® e.OM KI M ELAM ION 818006 PLATFORM ALL AAUP OMMETE I MIT. NM AREA R MULLED ® 11:A N N 00 I 50 BD PNN TO ADJACENT EMELT :AMBIT ON ORAL 2 EOM CMKTB IEEE ® AFTER I OAST TO WALL FUEANL MM. TOM.. IME T PLACE RI WAR•.EENON MARL ARID MOWS LACK YaET M ASM M R OR FIBOII ® conEE oYM I M EM JOINT Ewer FFLIM MAKI PLUM AM 55 TO 800FORM0 MOM IAT 00P/COETER)DOTTOM RREMN EAMI OP P.C. ERROR N BAN ONMT FLU. WM1 MM.. PORTION OF 101 MACE 8806880 MINT EE MAMAt80 N ORO8 TIM] Mm es P5 coRluonr'6o iTi mrlEnox M ooner INTUUTEII VALANCE O AMER 1104 OAP ON TOP OF T T MO MAXIM ROUE WOK PLACE MACK EDGE OF M10R MOT M AGM PLOW MOM OMNOED PO TON OF MOM. SOME CAP DOMN TO TOP OF EAON /EVERY MMM 8 FALAI. DORM OAP TO MION NM M MITERL UPIm O i V3 P A NT J IB ON o R w tumor 88 FROM TOM T OM PLO. a MM 1 MONO A18 M.N. CAP NW ANON JO JO.. OMER LM O NMT BLOW. Os MANRE M FOXI MAR EOM OP MRRMMATE OM AM INSTALL MA CT00 s Y EX W000 MEAT ONTO FORME ® NN et 3/ • 581 O OF R 8 1 M 1,4, RIME CAP, 8PL VALANCE M MORE TT. CAP A T 0 MEAT 0 RWALA TELY EC MAIL BOOT JOMM TOP OM TO ALEN N OMEN LIM Ca OMMf M M N O MOW. ® 0.14 TO MOM AM METALL E8D TAI PMCES ON ON MOON'S AT AM/ALL N OTE W TAI MCE EW 0658 TOP OF NM FLOOR TO WITT. OF DAMAN AT ALL OEM BIM. ® OW MEOW 10818 IMO AAMEN NO RLATOOCM M FROM MOH. FLOOR TO BOTTOM OF 90b M 88 row MO 8O F1M N N LL � N PA 08 O FRS MEMO JOIN TOTOP AND 10 I® 8101 MU. S LOON GANNET GEET JOINS ADO. ® A ell] . MEMN MO menu V4 • • 00LE1ED LINE TEMEAORM i •T• ONSETY. 'SAFETY N O IN ::mTE M MOM= EMMET A E GERM AND O M AMARD M NCI. MO41T. N N TO M MCMED TO IApI MI MI BOO ® • =role snows MD ORi0NS N ALL COMM - SOURLY BONA TOP TO BOTTOM JISTALLATION INSTRUCTIONS IR & 8 CABINETS) WE MENE LOWER 1 R 1.1 1i W MAM /ROOM M AMMO' WA OIRIL ATE AM MT No LACE PLATFORM SA MO. PLATFORM ALL M C MM. RIME _MMETE IMR •OD F ME A 0 AT A 111. HEW TOO TO TOP MO FRONT TO W. MIME. O.ROT MID MOM COMET M MA - TH. E AMMON.. Q LA 0 TO • MT1.0 w r MMES A.Cleoi M. MARK NO M EACH CASK/ TO SUPPORT M 10 MM. LEV= ® I L Nw MINN% SR .. Owl R CAM8ET, MK. O ML a� p ALM LAM MEWED OR AL MOM. MONT 1 cu oow io ro 1 P a ELI MO IHAE WINNE NOTE MITT ONO El V _ MTTCY C TO Mp11 MN MOMS. OP 0T MT o01ELOMED A18 VALAM E OY ex M M YIY O NI AT MTN B NEERDO S IINIE TO 11001.1 CAP AT E M. a E T R E vM OAP AND ALEIN /4 6M LOT 0X BOTH IT DAMS [AM EMT Mrt MNTE MORN CENTERLINE MOM AM MALL FMTMT MLIM SPACER LOOS SMM All VALANCE FINN PLO, MULL SPUME SR N 0MIMI W EN PA MEM. TO EI OM F FOMI AMEa MOL TO FSSIIM i mat E NN TO ]TOO AID GOTT. MEM ® M TO MOM. 11.11.1 M ALL OAAMTE - EQUALLY MACH OFNERAL NOTES O ALL PRREf1MN8l MO WORM O IMI 4 CWT. MO YENORI O WALL MELO MET ARE MOPED M MOM. a FE LD WI MIERA MCTE WIB � ID F A0INET MIRRORS ▪ ROVE®/MTALLED M 00.1 MSS FOR TIME ONOIO010 ME FM EMU u 18 aim v vM . CAM. WANTS. ME © 11000 I/4•.273/4•4 MM/M• ® 11 MME 1/4• .90/4 • 82 18/111• IIEMIG V4••15.•.ME MG LI NOT M OAS. HI , OPEN M OMMM COMM MN. SEATTLE, WASHINGTON AB NOTED sc M I O80 1 - 11 - 15 revised &awn arrEnUmn APR 2 3 1996 PERMIT CENTER O II FAIN V4•.bs /4•.NE/E•� /' IRE ED ` ...`/ , ' LL P y P ' /, , I T E CT WAFER/NAP M P10VMO 1150 NFfmM® NOW eAMAe WEDYINOMIDM .01 DETAILS OF L, M, N, P, R, S & T CAB. SOUTHCENTER MALL • ASTERISK 100>4081 M IMMON WOE TO TIM NEST 8580 6.2 1 O 1x6 0 000 O VALANCE PANEL. 4 ; REMOVABLE NGNAGE PANEL .® MTERMEOIATE /011X0' CAF _ /, ����'' II FURRING O NTLIZI VALANCE CAP 1 V3-\,� O I /1 '. POLISHED PLATE H VINYL BACKED SAFETY" MIRROR PROVIDED 1 INSTALLED BY GC. 158E SPECIAL INSTRUCTIONS/ ^'.: SHELF I 1 H OOD ®11 PER OM 3 SHELF BRACKET 12 PER SHELF/ SHELF/. O PACE OF UPRIGHT 6 (BEYOND) FRONT EDGE AND TOP OF • FURRING CABINET MUST FIT FLUSH TO. AND ALIGN 6TH, THE ADJACENT CARNETS \`/ 33/©36/4>(0 Sb5W000 03 BASE CABNET FURRING O i HOOD - w= O' O (13 1b] 34119 'dAll ERROR SLOT lI II I.4. L � FURRING m BASE TRIM: SCRIBE 3 TIGHT TO O H NISH FLOOR 2:E f � � co o VALANCE IA60VE1 SEE DTL.. CABINET 0120 -PANEL - NOLO FLUSH TO FRONT • 'EDGE OP CABNNE GAT END PRIOHT YL /N MIRROR ITVP) STRAIGHT CENTER SHELVES REGULAR, 3/4 SHELVEB CABINET END CENTER PANEL - HOLD FLUSH TO FRONT UPRIGHT EDGE OP CABINET CABINET 3/4' HOOD PURRI FLAT END UPRIGHT. IL /W I/O " X 2I/2" PLAT CENTER ,UPRIGHT UPRIGHT UPRIGHT 30 Q CABINET OL CABINET END TRIM PIECE RETURN VALANCE (ABOVE) SEE DTL RUN VALANCE (ABOVE/ TIGHT TO GYP. BD. RO0 ITYP. 3/4 • HOOD W RRIN FLAT OUTSIDE • CORNER UPRIGHT 3/1" WOOD FURRING ROTE ITYP �1 E %TENDED END SHELVES IL /0) UPRIGHT 30" OL CABINET FLAT INSIDE FLAT NOTCHED" FLAT FLAT CORNER CENTER UPRIGHT SHORT' SHORT' UPRIGHT UPRIGHT IL /H) UPRIGHT • UPRIGHT OUTSIDE CORNER bNELVES UPRIGHT 23 3/1 O CABINET /4 • W5 . 0066100 MIRROR ITYP.1 /4 • STRAIGHT CENTER SHELVES INSIDE CORNER SHELVES UPRIGHT CABINET 0 O/7 /4 • le. FURRIN IE UPRIGHT PRE - FINISHED % PRE-FINISHED HOOD PANEL WOOD' -PANEL .FACE OF TOP — — VALANCE CAP - (ABOVE) FINISHED PACE CONTINUOUS -3/4 • HOOP OF GYP. BOARD HORIZONTAL FURRING WALL (SEE SECTION LINE OF MIRROR SLOT. IN BASE CABINET BELOW AND VALANCE CAP ABOVE FLAT INSIDE CORNER UPRIGHT ® 0NMr 011.0 BACKHRAP COUNTER BACKHRAP COUNTER COMES ALSO IN 60' LENGTH - AND UTILIZES ONLY ONE SHORT UPRIGHT CENTERED ON COUNTER. UNFINISHED PACE OF UPRIGHT PRE- FINISHED N000 PANEL FLAT NOTCHED" UPRIGHT (R /H) PL OF UPRIGHT TO ALIGN MTH BUTT JOINT OP. BASE CABINETS: ITYP) - IRROR ITYP./ STRAIGT H CENTER SHELVES UPRIGHT 30 - <> CABINET SCALE: r - I' -0• FACTORY 0000080 . INSTALLED SET IN MA S T IO STANDARDS AND BUTT -TIGHT (TTP) TO STANDARD AT, 2 -SIDED CORNER UPRIGHT IR /H). UPRIGHT . UPRIGHT 30" O CABINET O CABINET DEEP STRAIGHT CENTER SHELVES ' 2 -SIDED END UPRIGHT IR /111 HOLD UNFINISHED END- OF CABINET TIGHT TO OS CABINET FACE, OF GYP. BOARD TYPE MD OR 'S' CABINET/ SHALL. STRAIGHT CENTER SHALCOU EXTENDED .END UPRIGHT CENTER SHELVES UPRIGHT 'END SHELVES I13/0) (R /H) OPEN 010 MIRROR) 4.. DEEP EXTENDED /ND SHELVES (8/10 UPRIGHT A -I DETAILED INSTALLATION PLAN - L, M, N, P, R; S & T CABINETS SECURE UPRIGHTS THRU MOUNTING LEG TO SIDE WALL Of BASE CABINET , BELOW ITYP.'OPEN' CABINETS 09101 CABINET END PANEL FLAT END UPRIGHT VERTICAL CORNER FILLER ROPER TO DETAIL' B: THIS SHEET V • 2 V2' END TRIM P00 RUN FROM FINISHED FLOOR TO BOTTOM OF VALANCE ABOVE (SAME APPLIED TO CORNER FILM X96 -oii�l FLAT OUTSIDE CORNER UPRIGHT 0.01 HMMN : N0 0820858) ® ® ®1> 09REET8 ® comer Otto A -2 DETAILED INSTALLATION PLAN - L, M, N, P, R, S & T CABINETS 8 2 HALF. SIZE FILLER - RIP DONN FROM SCRAP 'TEA STAIN' PINE BOARDS FACE OF FINISHED WALL RUN FILLER HORIZONTALLY I/O ' BELOW TOP Of CABINET BASE UNIT FACE OF — NISHED WALL CABINET FILLER DETAIL DETAIL CABINET UPRIGHT BASE UNIT 10ELON) END PANEL (BELOW 033105 B 3.2 FLAT CENTER UPRIGHT .(D TGAP.OP VALANCE, TES 641800)0N 11080.50 r HELD TO ALLOW FOR ONNE OUPPLIE0 51GNAGE DETAIL ()CONTINUOUS (ABRDGM f 3 '. (APPROX. 30" O.CI 2 - SIDED CORNER UPRIGHT ALL BY GL. SECTION THRU "L" & "M" CABINETS DETAIL 031206 6.2 2 - SIDED CENTER- UPRIGHT GAMETE I 1 1 1 �, Ar DOUBLE SIDED TOP VALANCE CAP - - � ` y ® VALANCE PANEL REMOVABLE SIGNAGE PANEL DOUBLE SIDED a Q VALA N CE CA VALANCE CAP EN MI RROR/ ® DEEP SHEL 11 PER UNIT SHELF BRACKET 13 PER UNIT', O2 BASE CABNET DETAIL FRONT FACE r O6 3 SIDED UPRIGHT -- (BEYOND/ FRONT / REAR AND TOP OF CABINET MUST PIT PLUSH TO. AND ALIGN WITH. THE ADJACENT 0050000 1TTP) 2 - SIDED END UPRIGHT I8M L/N 00008181 ® GAMETE —THIS DIMENSION MUST BE HELD TO ALLOW FOR OWNER SUPPLIED SIGNA0E. MOUNTING LEG OF UPRIGHT (SECURE TO SIDE OF BA E CABNET AS APPLICABLE CONTINUOUS SUPPORT PLATFORM W/ BRIDGING (APPROX. 30" D.L.) ALL BY G.C. ECTION THRU "R" & "S" CABINETS 11/2' • 1-0" 031266 D oa SHALLOW CENTER 0001/35 PRE - PMISHED END OF VALANCE /ABOVE) 000 CENTER SHELVES CABINET END PANEL PRE - FINISHED END OF VALANCE /ABOVE) ENO CABINET PREFABRICATED INTERIOR 6800 (APPROX. 30' OC./ VALANCE PAN � REMOVABLE 81GNAGE P EL 00001E = 1DE0 PRE N. TONED BOT'•M VALANCE SHALLOW SHELF H PER UNIT) � 9HALLON SHELF BRACKET 12 PER SHELF/ REAR FACE 2 SIDED UPRIGHT /BEYOND/ SCRIBE BASE TR TIGHT TO TOP Of FINISHED FLOOR 033185 8.2 Bath & Body Works THREE LEITE/ P0NWAY COLUMBUS. OHIO 43230 614- I79 -700> CABINET ASSEMBLY NOTES ENiIALLATION INSTRUCTIONS IL M. N P & T CABINETS/ RR 6000 FRAM 1141.. 01 Ns s®1 GOALE18E MME 89 w A 0 1 TEARUIe M6N err FROM TNT LM MD wueRn rRaeen 1 - CRIER• ME1Dx MARL • 0 14174 046 ,“6.111170 ATM v .1.0.11 MNIN1 llO MARK AND A R AND TO TO PLO. l FROM Of MM. ® e.OM KI M ELAM ION 818006 PLATFORM ALL AAUP OMMETE I MIT. NM AREA R MULLED ® 11:A N N 00 I 50 BD PNN TO ADJACENT EMELT :AMBIT ON ORAL 2 EOM CMKTB IEEE ® AFTER I OAST TO WALL FUEANL MM. TOM.. IME T PLACE RI WAR•.EENON MARL ARID MOWS LACK YaET M ASM M R OR FIBOII ® conEE oYM I M EM JOINT Ewer FFLIM MAKI PLUM AM 55 TO 800FORM0 MOM IAT 00P/COETER)DOTTOM RREMN EAMI OP P.C. ERROR N BAN ONMT FLU. WM1 MM.. PORTION OF 101 MACE 8806880 MINT EE MAMAt80 N ORO8 TIM] Mm es P5 coRluonr'6o iTi mrlEnox M ooner INTUUTEII VALANCE O AMER 1104 OAP ON TOP OF T T MO MAXIM ROUE WOK PLACE MACK EDGE OF M10R MOT M AGM PLOW MOM OMNOED PO TON OF MOM. SOME CAP DOMN TO TOP OF EAON /EVERY MMM 8 FALAI. DORM OAP TO MION NM M MITERL UPIm O i V3 P A NT J IB ON o R w tumor 88 FROM TOM T OM PLO. a MM 1 MONO A18 M.N. CAP NW ANON JO JO.. OMER LM O NMT BLOW. Os MANRE M FOXI MAR EOM OP MRRMMATE OM AM INSTALL MA CT00 s Y EX W000 MEAT ONTO FORME ® NN et 3/ • 581 O OF R 8 1 M 1,4, RIME CAP, 8PL VALANCE M MORE TT. CAP A T 0 MEAT 0 RWALA TELY EC MAIL BOOT JOMM TOP OM TO ALEN N OMEN LIM Ca OMMf M M N O MOW. ® 0.14 TO MOM AM METALL E8D TAI PMCES ON ON MOON'S AT AM/ALL N OTE W TAI MCE EW 0658 TOP OF NM FLOOR TO WITT. OF DAMAN AT ALL OEM BIM. ® OW MEOW 10818 IMO AAMEN NO RLATOOCM M FROM MOH. FLOOR TO BOTTOM OF 90b M 88 row MO 8O F1M N N LL � N PA 08 O FRS MEMO JOIN TOTOP AND 10 I® 8101 MU. S LOON GANNET GEET JOINS ADO. ® A ell] . MEMN MO menu V4 • • 00LE1ED LINE TEMEAORM i •T• ONSETY. 'SAFETY N O IN ::mTE M MOM= EMMET A E GERM AND O M AMARD M NCI. MO41T. N N TO M MCMED TO IApI MI MI BOO ® • =role snows MD ORi0NS N ALL COMM - SOURLY BONA TOP TO BOTTOM JISTALLATION INSTRUCTIONS IR & 8 CABINETS) WE MENE LOWER 1 R 1.1 1i W MAM /ROOM M AMMO' WA OIRIL ATE AM MT No LACE PLATFORM SA MO. PLATFORM ALL M C MM. RIME _MMETE IMR •OD F ME A 0 AT A 111. HEW TOO TO TOP MO FRONT TO W. MIME. O.ROT MID MOM COMET M MA - TH. E AMMON.. Q LA 0 TO • MT1.0 w r MMES A.Cleoi M. MARK NO M EACH CASK/ TO SUPPORT M 10 MM. LEV= ® I L Nw MINN% SR .. Owl R CAM8ET, MK. O ML a� p ALM LAM MEWED OR AL MOM. MONT 1 cu oow io ro 1 P a ELI MO IHAE WINNE NOTE MITT ONO El V _ MTTCY C TO Mp11 MN MOMS. OP 0T MT o01ELOMED A18 VALAM E OY ex M M YIY O NI AT MTN B NEERDO S IINIE TO 11001.1 CAP AT E M. a E T R E vM OAP AND ALEIN /4 6M LOT 0X BOTH IT DAMS [AM EMT Mrt MNTE MORN CENTERLINE MOM AM MALL FMTMT MLIM SPACER LOOS SMM All VALANCE FINN PLO, MULL SPUME SR N 0MIMI W EN PA MEM. TO EI OM F FOMI AMEa MOL TO FSSIIM i mat E NN TO ]TOO AID GOTT. MEM ® M TO MOM. 11.11.1 M ALL OAAMTE - EQUALLY MACH OFNERAL NOTES O ALL PRREf1MN8l MO WORM O IMI 4 CWT. MO YENORI O WALL MELO MET ARE MOPED M MOM. a FE LD WI MIERA MCTE WIB � ID F A0INET MIRRORS ▪ ROVE®/MTALLED M 00.1 MSS FOR TIME ONOIO010 ME FM EMU u 18 aim v vM . CAM. WANTS. ME © 11000 I/4•.273/4•4 MM/M• ® 11 MME 1/4• .90/4 • 82 18/111• IIEMIG V4••15.•.ME MG LI NOT M OAS. HI , OPEN M OMMM COMM MN. SEATTLE, WASHINGTON AB NOTED sc M I O80 1 - 11 - 15 revised &awn arrEnUmn APR 2 3 1996 PERMIT CENTER O II FAIN V4•.bs /4•.NE/E•� /' IRE ED ` ...`/ , ' LL P y P ' /, , I T E CT WAFER/NAP M P10VMO 1150 NFfmM® NOW eAMAe WEDYINOMIDM .01 DETAILS OF L, M, N, P, R, S & T CAB. SOUTHCENTER MALL • ASTERISK 100>4081 M IMMON WOE TO TIM NEST 8580 6.2 m 0 • MT I /4' THICK LAMINATED GLASS PANEL SUPPLIED BT GC. REFER - MEADE BY OWN ER DASHF EXTENT 0 r r�— - a 1/1• IX I /3' -. 6 I/3" NOT ". REFER TO 'CONSTRUCTION PLAN' FOR WALL LOCATION ROUGH OPENING- FRAMING TO FRAMING 1 i /1' 3 5/8' METAL STUDS • M OL TE PHOTOGRAPHIC n U N RCHANGEABLE MURAL PANELS''REFER -.,TO DETAIL C {THIS SHEET 1 "V1• 'FOR MOUNTN4 INSTRUCTIONS, - OF GYP. BEYOND. i E Of RAISED CE ILING ®. ® -- -__ - - H EAOER R TRIM SHED 3. DOUBLE TUBE STAGGERED PLUORESCENT LIGHT I REFER TO 'LIGHTING PLAN' - - ww....- c :. aouamvrwa, w BUTT ,wine P — y LsQ1 H� FOR STYLE IiYP.),' -1 I I 5 /e' METAL � �e� iS E R � �II � 1 -A � sswnrx, aa< aw: anmac• wa;;aawm�m,xum.awmw�awwnva.a... ......��awmwxa'ac .+wnnwa.aawv�mws x,w..e ar.. .,..a.:,.....,:.w.... • .LE/II 5 - I I I HH i J A ` � 1 _ ,11.� II 11/1111111 9/£ E -.I .5/5 5 -J \ - 5/8• GYP. BD TYPE 'X'ITYP) AM ® - - _ 'x 3' PREFINISHED PORT TRIM ITYPI P AINT GYP I BD y��- }- - LOCATION OF LAMNATED GLASS PANEL WTH SIGNAGE ! r - � I M= Q H OOD SIG AGE 1 FRAME) 1 i I 1 1 f 1 I� Q I ° WO00 91 R NA 1 1 A ILOCATI 1 NTERCHAN PHOTOGRA PANELS PRESENTATON Of THIS SEN EABLE MURAL REFER TO PLAN STUDS IABOVEI - SEE OTL D/TI MIMI 1 11 �I �� `� ` I , w - — 1. °/n ®� \� \ / ... ]' -5 I /4' W _ - I �_�� :I �� .. ' ry - -I_ ® —� .�_ Il � n 1 n1 BIJTT JOINT ITTe.) ® MY REPER TO PRESENTATION PLAN OF S SET TIN I ' TYP. EA. EDE) A' " -- l \ \ �� ® / 3/1' PLYWOOD FURRING CONTINUOUS FROM TOP Of BASE BLOCKING t0 ' SIDING) (BEHIND WEATHER BOARD NEATNlR MEG EBOARD ` J' " >iif fiJ » ii' I �/ �� BACKHRA / ®� r/ H EATHER BOARD 801NG rr BACKH AP C U E �il/l/ N.Na#°91T/irjfrA° �.. R % / /. /,/ / /. � fi' N. PREFINISHED ARD STOP HEATHER BOARD SIDING EHNIb ED HERE SEE DTLF /T.I ITYPICALI 6• H PR ARD SIDING BASE CUT AND BUTT SIDING BASE . 6 3/1' - - AN 510E OF BE AND END TRIM BEYOND NOTES BASE TIGHT I I TO EDE Of BACKWRAP ITYP,) O FOR WOOD SIGNAGE AND FRAME DETAILS AND THEIR LOCATION REFER TO PRESENTATION DETAILS OF OF THIS SET. BACKWRAP WALL AND LIGHT .130X ELEVATION SIDE) (TYP. EA. SIDE) 1' I O OFFSET OF BACKHRAP AND FACE /POST BEYOND l' - O' a 3/1 -10 I /2' FINISHED OPENING DIMENSION - OVERALL DIMENSION ® VA ELEVATION BACKWRAP WALL PLAN • .. 031298 ,:. 031298 DETAIL 7., DETAIL 8 7., 1 HIM SPACE l�3 /8' . CONY. 24 BLOCKING ITTP1 2x ]' TEGULAR LAY- IN 2' T XG LA D.C. 3/1' PLYWOOD FURRING BEHIND HEATHER BOARD BIDING ITYPICALI f G OPTION, U6EBISnEATER4 UO J PLYWOOD I/1' SHIM �• ' 1T• IN LIEU OP ]x5 SPACE ITYP.1 11 PREFINISHED ' n i t' TRIn IMP a MTL STUD 16 OC 1 I 1 -- - DM ® NOTE. G.C. TO REFER TO INSTALLATION MANUAL PROVIDED WITH TRIM PACKAGE - GC. TO ]' HIDE CONSTRUCT CONTINUOUS SLOT USED • 5/8' GYP BD. �) FOR RETURN AIR 1 1 MTL STUD Mg. / u 1w p 6$p�1 B I /4' CONT]x6 BLOCKING I S/W METAL TRACK FATTENED 5 /8' f.r OPTION - USE 12/ LAYERS 3/4' PLYWOOD IN LIEU OF 1x6 I � = NOTE BLOCKING I PIECES TYPE X' ITYPI '- Pi rim � NOTE: APPLY ADHESIVE BETWEEN BLOCKING 1 TRIM PIECES 41,11 TO • -- I aI II II _ A 1 - _i !� - PAINT GYP BD HOOD BLOCK 1 .1 ING - CHANNEL SUPPORT FOR ' h I �= �' ' OC. ' �i IIII ,IIIIIUIII1I11111I111IIIII _ PAINT - PLYWOOD AT REVEAL TO INSTALLATION BACKHRAP ., Iii fin R i� EFER TO 'REFLECTED CEILING PLAN' ' } � -5 � —'— j j _ -I I PHOTOMURAL - PROVIDED BY OWNER INSi LEO BY G.0 DOUBLE TUBE STAGGERED LIGHT REPER TO •LIGHTING PLAN' x4 - I _ \O I x F V OD BLOCKING REH 261 WO 86®( v , �' 1/4•. �/ • ; • 1 ® E F I � ■ • TO EVERTVERTICAL STUD LON 1W BLOCKING fTYPI FASTENED TO I6 /8' METAL — ' SURFACE PRIOR C ' OP BAKHRAPFLUORESCENT 4� 1 e•=1',.! . 3/1' PR EPN16XE0 I' :. 1 1' 1 I/1' I 'NNW// TRACK, nC OPTON USE - " _® J ; _: � !Mr - FOR bTYLE ITYPI III/ ' VERTICAL LAPPEp STOP WEATHER BOARD SID NG AT I EXTEND PREFINISHED HEATHER THIS LOCATION AND NG • BOARD 51DN4 TO TOP OF 146 BASE BLOCKING SIGNAGE FRAME REFER TO PRESENTATION DETAIL bHEET(sl OF THIS SET • 121 LAYERS 3/1' PLYWOOD IN LIEU OF 1x6 LINE OF 1 1 -3 3/8' I/1' SHIM SPACE all., j— DI � I'l'IA � -� �� f REFINISHED 1RTFPII „ IN LAYERS 3/1 ENDS TOP VERTICAL PLYWOOD AND BUTT AND TIGHT TO SIDE WEATHER BOARD II ( II I II' NOTE APPLY ADHESIVE BETWEEN BLOCKING AND TRIM PIECES 1/11 VS' HOOD QUARTER PLYWOOD OF PLUSH II I II I OF 111 SIDING I III / S ��W\N �1Y'{DF O v F DETAIL AT OPENING INTERCHANGEABLE PHOTOGRAPHIC MURAL PANELS PROVIDED BY OWNER INSTALLED BY G.C. - CONTACT CON- STRUCTION MANAGER s ROUND GLASS STOPS - CONTINUOUS AT PERIMETER OF GLASS PANEL (TYP BOTH SIDES) PROVIDED AND 'IMAM ail � ® :4 ,A JAMB PREFINISHED Il 3' 3' HEADER TRIM .III INSTALLED BY GC. 3'x 3' PREFINISHED TRIM _� � t �,/ �® LIED AND INSTALLED BY 4 C SIGNAGE PROVIDED AND INSTALLED BY OWNER 3 , 1 6 NA �� 031296 Q ' DETAIL 00 NG0N1 7.1 L OF VERTICAL 3'x 3' PREFIX.. POST •. TRIM /BEYOND) A�� SILL DETAIL AT OPENING (GENERAL NOTES( .5/1 II -.£ 1 17101.1.1 HEAD DETAIL AT OPENING PAINT GYP BD ® 'CHANNEL SUPPORT FOR - 1' 1 1 I IN IM1 m .Y /E a -.£ 1. ALL FINISHED TRIM PIECES SHOWN ON THIS SHEET ARE PREFINISHED (DISTRESSED WHITE) AND SUPPLIED BY OWNER TO BE INSTALLED BY GENERAL CONTRACTOR. 2. INSTALL ALL TRIM PIECES SHOWN ON THIS SHEET WITH FINISH NAILS - SET NAIL HEADS. INSTALL OVER CONSTRUCTION ADHESIVE. ADHESIVE NOT TO BE EXPOSED. 3. TRIM IS SUPPLIED WITH TOUCH -UP PAINT. GEN. CONTR. IS TO PAINT ALL EXPOSED CUT ENDS OF TRIM. USE BEST JUDGEMENT IN OBTAINING SAME DISTRESSED FINISH AS ADJACENT SURFACES. 4. PHOTOGRAPHIC MURAL IS TO BE INSTALLED BY GEN. CONTR. PRIOR TO THE INSTALLATION OF THE ADJACENT WINDOW FRAME - GEN. CONTR. IS TO BE RESPONSIBLE FOR PROTECTION OF PHOTOGRAPHIC MURAL DURING CONSTRUCTION. FOR INSTAL- CATION INSTRUCTIONS FOR PHOTOGRAPHIC MURAL - REFER TO PRESENTATION DETAILS OF THIS SET. 3• ° r - o' - 3' - C 72°B PHOTOMURAL - PROVIDED BY OWNER NSTALLED BY GL - D ETAIL _ -. ® 7.1 DETAIL G 7.1 .1 WOOD BLOCKING J I I : , / + -- dV51n]ove 1 �'. 03 1298 3/1' PLYU000 BLOCKING NO1103S d31NfOO 5131530 .OI -Z 15 /SL ATE STUD ONE LAYER s SIDE Tree x' GYP. 0 STUD ' % � � �" APPLY ADHESIVE eETWEEx HEADER OR POST TRIM To CUT AND Burr END of rF HEADER OR POST TRIM TIGHT TO SIDE OF 'L' TRIM G-4 POST TRIM IN - PLAN RE A D W AT FIRE RATED Au 3 6 /BOCTL STUD ) BncKWRAP Loux eR - F '' L' TRIM ITYP.1 7.1 3 I 0 i1�� ALIGN FRONT FACE OF POST TRIM NTH EDGE OF STEP IN L TRIM 1TrP.) STEEL CONNECTOR .�, ELATE SUPPLIED AND INSTALLED BY GC. ON BACKSIDE of POST/ HEADER 050 ) ( I m POST � 1 ,_ W HEADER OR POST TRIM TRIM IN PLAN G -2 CONNECTION TO T' TRIM = a ,:_ 3' 3' HEADER TRIM 7 P x T TRIM POST TRm - AND BUTT END OF DETAILS OF WALL BEHIND BACKWRAP CUT HEADER HEA rl HEADea TRn TIGHT To NOTE I INSTALL ADDITIONAL BLOCKING MOM A B "" IF R"° NEEDED To B a�T 7I-� �r Bo SOUTHCENTER MALL 510E OP PObTPI HEADER TRIM CONNEC• cI a 3 "x 3° POST & HEADER DETAILS G -3 TION To POST TRIM APR 2 91996 14 BLOCKING -SCREW To WALL STUDS BACKWRAP WALL SECTION CA l 11 lJ1 T E 1REATTLE, WASHINGTON WNW 7.1 3 = °. FEemT cENiEi FASTEN FASTEN RA':KWRM TO WALL WALL 031296 Wo rks NOTED dale I 7 • . 1 7.1 .. ... DETAIL C 7.1 DETAIL - 9 7.1 0 UXA ,ewe T 04E0 LIMREO PARKWAY COLUMBUS. OHIO 43230 AM m 0 • MT 1 1 /2' - FOR FINISHED WALL DIMENSION - REFER TO °CONSTRUCTION PLAN' ' .� - - 1 1/2' EXTENT OF PLYWOOD BACKING BEHIND WALL TILE - WITHOUT 3/4' EXTERIOR GRADE PLYWOOD CERAMIC TILE SUPPLIED BY OHNER. SINK AND FAUCET SET SUPPLIED BY '• IINSTALLED 3/4' EXTERIOR GRADE PLYWOOD • BACKING BEHIND WALL TILE _ a - BACKING BEHIND WALL TILE OWNER AND INSTALLED BY GC. - HOLD ON CABINET COUNTER ?OP BY GC 3/4 CONTIMUWS PLYWOOD FURRING - SCREW TO EVERY WALL STUD AT 16 O.L. VERTICALLY. RUN FROM TOP OF DABS BLOCKING TO CEILING AS CLOSE AS POSSIBLE TO BACKSIDE OF SINK NOTE, • ARRANGE CREAM AND WHITE TILE M A RANDOM PATTERN. REFER TO DT, FM 3 KW ALL BASE - ARRANGE E RED. NHITE, 1 CREAM TILE IN A RANDOM PATTERN. TAILP .3 REFER T:::: AM WALL CARNETS MAY BE MIMS BY OMEN INTENT. 1 REFER TO 'CONSTRUCTION OPP � ro - ,I �'� NOTE. SOME STORES MAY O 1 I ® . SI CONDITION WRH ADJACENT'CABIET TIOM TO WALL COMNTMN LN1110ur F NOT REQUIRE A SINK aZITID RUN PREtMB1ED =NO DOWN TO WALL BABE �-1 OPP t i !! l �l__ I ■ E�® I 1 l HHEN OCCURS 1 INSTALLE GC. SUPPLIED BY °LINER SHELVES ® Alt Q PRE- FINISHED HEA BOARD SIDING �BAT C - CRIND DASH LINE INDICATES EXTENT OF PLYHOOD BEHIND CERAMIC TILE lit DOTTED LNE INDICATES ■ 1�.'.■'�- ,,„. i I ,,..,, ,. _ -- - I iArri iii - ___ ___ 0'3� 1 i - REHED -BOD 1 . L DINAC OII FX�_ V 1:I 1 I!i! II IJ11I1 ' t . -11� F paw OF WALL ASE HT TO 61DE F 9 NG BIITT I CT1 O-FR ■ Y 1 _ I_ I. I ®.' I - EQUA • 3' -0' 1-' NO GC. TO CUT BULLNOSE AND RUN CONTINUOUS TO BACK WALL EOVAL NOTE. AT COUNTERS UTAf®C��CM� " . EXTENT OF WEATHER BOARD SIDING IBAC-OII BEHIND WALL CABINET WITHOUT SINK CONTINUE FULL TEE PATTERNI��.U�A1JO AS SHI NN. REFER TO DTL. F /12 0 1 - -��M1 �' - BMBEEV ��� 0 %M 1 � • 1 ■ :: f1. AMIE HET BBOBE ® 3' 0' 111111 I I 'Lit NET&: CENTER FIRST ' ND Q SINK A FAUCET AND TILE EQUAL ® .. — ®m ! ® Il I TILE AT FRONT OF COUNTER AS SHOWN. � ® EQUAL • CABINET COUNTER CERAMIC TILE NOSING 2' -0' - KNEES � Y111 . � Y �' IIYrIr11 II [I I -U TOP HINGED TRASH FLAP DOOR Y1 I I ` 3' -O' < > II IN PRE-FINISHED 6' 4 3' -O' ■ ®_ WEA HALL BASEO 8163'NR W.W. CAMP DMtlR AN CRYPT AND BUTT TIGHT TO BRAWN BI6Mp SIDE OF CARNET OM CAME, WALL CANT 1 TYP 1 (NELVXE WALL CAB NET DRAWER BABE C Bit BABE CANVEY DRAWER BABE CABINET NELW O WALL CASKET. 0' -0 OVERALL CABINET DIMENSION BA BM CABARET ELEVATION OF DEMONSTRATION AREA CABINETS 031296 ♦ Lk ® PLAN OF DEMONSTRATION AREA CABINET LAYOUT ELEVATION 031296 DETAIL �.2 DETAIL 7.2 REFER TO 'LIGHTING PLAN' 1 r . ® ��0���� PRE INISHED WEATHER BOARD SIDING IBAC -014 REFER TO DT A/BI.' OR TYPICAL INSTALLATION - DETAILS AND NOTES 4140 40 1 REFER TO REP PREFINISHED WEATHER BOARD SONG 16AC -011 REFER TO DTL.A/0 FOR TYPICAL INSTALLATION DETAILS AND NOTES " "' PLYWOOD °'° "" BEHIND REATH. BOARD SIDING - RUN FROM TOP OF BASE BLOCKING TO CEILING NOTE BLOCKING AS NEEDED In �EI ®I ®I.� �— REFER TO REF mm _ - - CEILING PLAN ® N CEILING PLAN �-_�_.S_O DD ©0©��ODD I♦ 1 o TOP OF CABINET IS SUPPLIED ®��� ANGING LIGHT FIXTURE R . GMHTING PLAN' LOOSE AFTER FASTENING 1 1- CABINET TO WALL FASTEN 1 J� OP O CABINET USING ® 66-06 410 00469 II ©� ©��� ©000©� ©0�D ©�� ® I 1 I 1 I :e SF -t MOUNTING EYE HOOKS ARE PRE INSTALLED ON BACK OF SHELF. G.C. IS TO SCREW DDD fl © ©MfD©h1f�0fl©fl© CERAMIC TIL 1311:1113131301301310131:1131:11510191:11:101 C - CREAM TILE W - XMTE TILE R - RE TI D L 0 0 B=•f! 0 0 o I 0 ' I 1' INECIMINIM �RBRNIF,F7RB>•S' II '� ' J I NTO W EATHERBOARD - SIDING AND PLYWOOD BLOCKING BEHIND C SECTION 4TH SCREWS - PROVIDED. 0 BIS p NM TILE ON WALL ' 1.111. I' i / CERAMIC ' I i' 1 II 11 WALL CAEINE (BEYOND, O - C W W 0 ' c' W , 'C 0 0 3®®®©M©O ©C ©0 4 W L cc L W 4 C C N C N N C N W 4 COG C N H 01 0 0 BE 4 0 04 00 04 8 01 C B W CI ' ' ' C W W W u M®©WE ©� a� EE LL W H C C" I' C 4 L � C C C C 4 N L C W C C L W N L C 4 L L L 4'E L y W 4 - - -- x j - 031296 ,I : 110 — C N � ! I I __ % PREFINISHED SHELVES - SUPPLIED BY OWNER AND INSTALLED BY GEN. CONTR. REFER To Dn. Ens FINISHED FLOORING - REFER TO "FLOOR AND WALL FINISH PLAN' °[a ©R:E W = DECORATIVE HOOKS PRE INSTALLED ON FRONT FACE OF SHELF. I To CERAMIC COUNTER SF -6 CERAMIC TILE � — PARTIAL ELEV. C - CREAM TIM N -WHITE TILE SHELF MOUNTING INSTRUCTIONS TILE ON - WITH SINK CERAMIC TILE ON COUNTER - WITHOUT SINK 1/ ,I R6 R TO FIN104 SCHEWLE ON SHEET 11 FOR CERAMIC TIE DEBCRIPTIONB CERAMIC TILE LAYOUT PATTERNS .-■■•■••■ 3 04' X r PREF... C AP TRIM BUTT ENDS TO WALL CABINET o NIGHT ' � _ —TO BOTTOM of WEATHER BOARD SIDING SEE ELEVATION B /12 NO SCALE 041394 3lll OIN gr SMON llNj (YI IN05N3NIO SIN1 OION) .I 1 1 0;. PRE FNISHEO WALL CABNET CARNET IS SUPPLIED WITH 66 , PRE-FINISHED ADJUSTABLE SHELVES. SHELF BRACKET J - I 1 - J. Q!w ni zQ - SF T I CERAMIC TILE CERAMIC TILE NOSING DETAIL E , Z DETAIL ,.Z I — 1= ' l I - 11 - 9/4' EXTERIOR GRADE PLYWOOD - RUN FULL WIDTH BEHIND TILE - SCREW TO 0064106. I SF -6 ' CERAMIC TILE ON COUNTER - - - - b....... IN DEMONSTRATION tlOFNED SUPPLIED BY OWNER, p p 9ROV CONTR. 101°6 AS ILLUSTRATED a N601`M51ON SIDES TOGETHER CABINETS IN PRE - PROVIDED BY OWNER, CONTR. REFER TO DRAWINGS FOR � F pry MAY NOT HAVE A SINK) APP 2 , l2 6 LEVER TYPE. >Da.T CVO. GENERAL NOTES 1. ALL CABINETS AND SHELVES AREA ARE PREFINISHED AND TO BE INSTALLED BY GEN. 2. FASTEN CABINETS TO WALL ON THIS SHEET. BOLT CABINET USING BOLTS PROVIDED WITH DRILLED HOLES. 3. SINK AND. FAUCET SET ARE TO BE INSTALLED BY GEN. PLUMBING SPECS. ON ENGINEERS DESCRIPTION. (SOME STORES NOTE: SINK HANDLES ARE / i -- - -_ 40100111000 03NSINI4 40 .101 .01 -.0 .f -,Y 2.6 BASE BLOCKING SCREW TO EVERY �_ WALL STUD TOP / CONC. SLAB BABE CABINET 3/4' PLYWOOD FURRING BEHIND WEATHERBOARD SIDING RUN TOP OF BASE BLOCKING TO CEILING NOTE: I INSTALL ADOTIONAL BLOCKING TN BASE 00619619/0 WALL • 2,6 BASE BLOCKING SCREE TO EVERY ALL STUD TOP/ CONC. SLAB Ir : "' ` , �/ 1 ' / 1 T I STOP FLOORING FINISH AT CABNET 01014 BASE WALL SECTION THRU BASE CABINET (DEMONSTRATION AREA) STOP FINISH FLOORING AT CABINET BASE WALL SECTION THRU - SHELVING WALL CABINET (DEMONSTRATION AREA BULB V( f B STEP 6 - l j Work U' Y , I � R .A DEMONSTRATION AREA DETAILS SOUTHCENTER MALL SEATTLE, WASHINGTON w. 03,296 091288 scale OBt. Oro. B 4-I9-11 1m6 A NOTED DETAIL DETAIL 7.2 owl ad 7.2 /NM WNITTD oLxxBN= OM 42R \EN • k coo . 48TEE31 NDN:ATM ND 60011405 MADE 10 TM SMUT 3' ACE TO PACE OF METAL STUD FACE TO FACE OF METAL STUD - - DECORATIVE BEAN ' (r `- 3/1' HEATHER BD. ': BD &ONG IEEE 'CONSTRUCTION PLAN')' :. ': " :.. " -' (SEE. CONbTN�PLAN') a ,. ) 3/4' HEATHER B0. : `. -,. .:03/4 HEATHER BO ' . ^ WEATHER BD CONTINUOUS PLYWOOD . EAT SIDING W GIFT BASKET FIGNAGE - REFER TO PRESENTATION ETAILS OF NI Ei PLYWOOD BD. GOING 3 5 /B' 120 GA, MTL. STUDS AT WINDING SIDING M NT TO SECURE CABINETS FURRING - RUN FROM I I 3/4' PLYWOOD 3/4 PLTWO MOUNTED HORIZONTALLY FLOOR SLAB T° TOP IJD 'LYWOOp Q ' FIXED SHELF W/ HOOKS ,® j i 3/1' OF HALL REFER TO 1 ' S EE NOTE BELOW 1 SECTION C THIS SHEET ` ' �� xLLL / / / .. 0 WHEN OCCURS 1 _ XI , , � . PP. Q 'II I I I I Ath ,.. - 2 /2 METAL STUD O I . �I�, _ /- ` I .',�, - _..... __.. .- ro FRAMING / ��4I -- .. .. -� -- - ^.3V. r _ _ I . I E i - I ' 1 1 L _ _ _ , Fp I _ r . PRESENTATION ITEM - SEE PRESENTATION RYP.1 WOOD SHIM AS REQUIRED 0 OPP � � �II '�F - I ■ ..� ' - PREFIXI6HED LATTICE -_wr. ..x� I � ,� '. �� , i �Id f�B IBRB rig E' 1 : 1 ENTER UPRIGHT .1 i -- L HIV TN CENTER UPRIGHT . LINE OF DECORATIVE O ® ��- �- J I , �e �d ■II U U UIUI 7 I �� �I •.. ... END I E� UPNONT 3 6/8' STUDS', ® ® B I &M �' SIX• TYPICAL END CONDITION ' IM N N *.eI IS' ADJUSTABLE SHELVES W/ BRACKETS ITYPI - _,�,\ UPRIGHT III 6111111 MINI I I ® - - _ _ ����'� �'' PANEL (TYPICAL, :CABINET BASE DETAIL. N ' - - 5 /8' GTP. BD. OVER PLYWOOD IM BlIB11B1 EIEI BEAN ABOVE NOTE, : ' CEILING U I T H.TU E I TO ALIGN WITH THE PAGE - 11 I•1 MIS • . ...�..1 a. 111 111 UPRIGHTS H/ STANDARDS (TYPI PREfINISH @D LATTICE PANELS (BELOW ALTERNATE END ` .f. 'WE WHE WALL CABINET OCCURS IMMEDATELY AIN TO THIS NAL DO NOT INSTALL BASE 1111111111111111111111111 ® OF PLYWOOD CONDITION ICI /I�IlILN.r. A RCS GROUNDS Y ]' -CLEAT \ 3/1 O N 3 6/8' METAL STUDS 116' O.0 ) .NOTE. PAINT WALL 13 'PRIOR TO START AI CABINET INSTALLATION BBOIBN 111/1/1/1111.1-1 (SECURE TO ' - . .LINE OF FINISH @D BASE TRIM BELOW NOTE: ALL GARRET COMPONENTS ARE PREFNI O W AND - , PROVED BY OWNER (UNLESS NOTED INSTALLATION I BEI FOR EETALLATION BY O.C. TRIM ON RETURN MGM INSTEAD . RUN BABE TRIM ON FRONT 'HALL OVER AND BUTT TIGHT TO CABINET END PANEL ® IF II PREPINIBHED HEATHER BD. SIDING (TYP') 20 ADJUSTABLE SUPPORT PL'ATRORMI ( / FACE OF ® ®7 �/ `_ 11 811 181 YIMINI[IE� 3 Y 1 OF HEATHER BOARD BELOW _ _ BASE BLOCKING : 1_. • 1 I 1 L _ _ J 1 SHELVES - SUPPLIED BY OWNER /INSTALLED BY GC. ITYP, `V� SUPPORT PLATPORM 1 OUTSIDE FACE / OF UPRIGHT ® 36' CABINET •`.. �¢ OF UPRIGHT OUTSIDE FACE - OF UPRIG T -jl 36' CABINET : ` PREFINISHED WEATHER BOARD BABE TRIM FIT TIGHT TO CABINET \ SUPPORT PLATFORM P ASE TRIM - CABINET BASE TRIM BUTT TIGHT i0 FAZE OF WEATHER \ \BD BASE TRB1 II I ,-f OF UPRIGHT - 3fi' CABINET 1 .. r _ �.. T PREFNISHED CARNET `PREFINISHED HEATHER TRIM BD. TRIM ITYP.1 (TYPICALI ; .BASE BASE - - , ELEVATION OF BASKET AREA CABINETS Ark ® . ELEVATION PLAN OF BASKET AREA CABINET LAYOUT, NOTE REPER TO DETAIL A /81 POR TY %CAL PREFIXISHED HEATHER BOARD BIDING ■NSTALLATON DETAILS � •' END AP 3 � ' CABINET • ��IABOYEI 03112O6 VY -r 0 071196 DETAIL ;.3 DETAIL 1 BLOCKING / FRAMIN G BY G C r SEE MgCATED - GIFT BASKET AREA INSTALLATION INSTRUCTIONS L - AFTER WORD FURRING INSTALLATION HAS 1010 COMPLETED: OI LOCATE MN POINT OF FLOOR ALONG GIVEN DISPLAY WALL, LEAGUE UP 30• MID SNAP A LEVEL LEE OF THE WALL (BENCH MARK), THEE LEABURE DOWN 24• FROM THAT LIE EN TIE SNAP ANOTHER LEVEL LBE ROWER BCIBNRKI RETUNING TO T ORIGINAL LEE THE TIE MEASURE IN 24• AND AGAN SNAP A LEVEL LM ZIPPER I ' y �sT(1 ® 2' 2' TEGULAR LAY - IN 00701. f - � _ CEILING BY G.C. irk e� a FENCIBNRK) . . REFER TO O 'CONSTRUCTION PLAN FOR LOCATION OF ADJACENT'FRANING/HALL - • _ 5/C GYP. ^BOARD -. OVER 3 /1',PLYWD:" ON 3 5 /8' MTL STUDS PANT WALL Lai! BEFORE STARTING ANY CABINET Iii I�� _ '� - 3 5 /B METAL STUDS 16' °.C.1 BY GC. - CONTINUOUS 2 x 1 :. 5, V IS TO 50050 ® FABRICATE 7.0 MO �. KONG TOP WO SUPPORT 505FA PLATFORM RM AS TIE TOP EDGE 0 OTg FRONT AND REAR 2X03. HOLD TOP REAR OF PLATFORM FLUSH WITH 'LOWER BENCH MARK AND SECURE TO PLYWOOD DROOPS, KEW FRONT OF PLATFORM I I I PREFINIE 3H0 'L' TRIM SEE INDICATED DETAIL i CONTINUOUS ' - . BLOCKING BY G.C. SECURE PERIMETER CEILING ANGLE TO NI9 PIECE : HOLD , ANGLE /T GOWN GC THRU HEATHER BOARD SIDING AND NTO N000 BLOCKING BEHIND WITH 121 I O, WO x 2 1/2 WOOD *311 AND SECURE TO 2X4 SLEEPER LEVEL REAR A 3 LOCATE AND BET N PLACE IOM SUPPORT PLATFORM ALL BABE CARNETS TO BE METALLED WITHIN MS AREA I FACE OF UPRIGHT ICONTI NUESI III FROM BLOCKING SCREWS AT 16' °.0 SECTION 4 ONE CABMIT'AT A TIE, VERIFY TOP TO TOP AND FRONT TO FRONT O AUGMENT WITH ADJACENT CAK/ET AND SECURE CARNET SIEB TOGETHER WITH SCREWS MEP@ CARNETS. WITHIN AREA ARE TO S SACK ® I III -1, II I PREHNISHED WEATHER BOARD SIDING MAC-011 I6• DEW FIXED SHELF: SEE INDICATED DETAIL BLOCKING BY GL I 1 � I� it I ���� 1 11 ]' e, � , P ' r i . - L' : A - - ^ " ® 'I'IIIIIIRIIIRIIII111Hl11 • `- - 10' 6' AF.P . x 2' TEGULAR LAY N CEILING GC ENTERED 6ETYEE/1 E10 WILL RECHECK 6.611116/17 B T � OVERALL (PLYWOOD E 'UPPER BENCH MARK AND SECURE EACH CARNET TO REAR WALL PLYWOBO EATEN I , I _ .I I 1 ® IA h / I I I O O ® ASSEMBLE AND METALL DECORATIVE WOOD BEAM ACROSS TOP OF DISPLAY WALL : ALIGN BOTTOM EDGE OF BEAM W/ UPPER BENCHMARK. ® LEASURE, . CUT TO BEE, AND INSTALL WEATHER BOARD SONG ACROSS TOP PORTION OF DISPLAY WALL 1 HOLD 76117 TO BOTTOM ALL OF DECORATIVE SE 0 SET / 518TALL UPRIGNTB M ENE CENTER PIECES 011 CENTER OF GANNET TO CABINET 3/4 PLYWOOD 5 /B' GYP. BD I I I _ I - . _ 1 1 • f 9100005 BY OWNER : SEE 'F3550NTATION PLAN' FACE OF UPRIGHT . PI I - : JONT AND END PIECES 80 OUTSIDE FACE IS FLUSH W/ FNISIED END OF CABBET, MAKE - PLULE AND SECURE TO WALL AND WEATHER BOARD SEIKO A IM UPDONTS /WOULD FIT TIGHT BETWEEN TOP °F CAKKT AND BOTTOM OF DECORATIVE ADDITIONALLY VERPY AND MAINTAIN BOR¢ORAL SPASMS 167.101 WEIGHTS. O FABRICATE PANT IP -131 AND METALL HORIZONTAL BLOCKNO BETWEEN UPRIGHTS ACROSS BOTTOM OF WEATHER BOARD SONG, PRENNIBHED 0 PROVIDED BY OWNER GC. - • TO PROVIDE INTERIOR CLEAT - M1 BET HEADS. NG IM I6T O NA ILB LENGTH ON SITE, SHELF BRACKET PRE -INSTALLED (TYPIC , • ALI -- :. DECORATIVE HOOKS P ARTIAL ELEV. (TYPICALI NSTALLATION " CONTINUOUS 5/8• O FACE OR HEATHER BD. WALL BEYOND HOLD TOP OF UPRIGHT TIGHT TO BOTTOM Of DECOR ' SHELF MOUNTING INSTRUCTIONS ® INSTALL LATTICE PANELS BETWEEN ALL RIGHTS - SHOULD FIT TOOT BETWEEN STANDARDS SIDE TO SIDE AND ALONG TOP OF EASE CARPET AT BOTTOM G N6TALL PEED SHELF BY SECURING TO UPRIGHTS AND BLOCKING BEAM ." SECTION CO PERIMETER CEILING BEAM 15' DEEP ADJUSTABLE SHELVES u/ IV BRACKETS O PER SHELF, 3/e 6/8' LATTICE PANEL 3' 0' NO SCALE 0 INSTALL ALL ADJUSTABLE DISPLAY SHELVES AND BRACKETS O RD 8 - HOLD EGUAL SPACES BETNEIN BOTTOM OF FIXED SHELF A TOP OF BABE CANE(. ,5 SCREE AAS W A RD TO AIEL�SIVE. WEEP NAILS *8 0. FR AB POO88EILE 70 PLATFORM Y 9380 50TIOM EW EN, NOTE ALIGN ENT JOISTS WITH 011007 300470 ABOVE. - ,.• DETAIL 031288 D .3 DETAIL .. . 071195 � ' 4 I' n T 6 LONG UPRIGHT NOTE STANDARDS ARE PREINSTALLED ON REFER TO DETAIL F SHEET. FINISHED FACE OF � y(l P R 0 0 It' N \I DIH 15lO GYP. BOARD WALL FINISH NAIL UPRIGHT TO WEATHER BOARD , 20 18 BRAC KETS ( O 5HELF5 BASE CABINET - CABINET BASE TRIM HOLD TIGHT TO CABI AT TOP RISE SC TIGHT TO FINISH FLOOR AT BOTTOM 2 x 1 BLEEPER BY G.C. -RUN r j, , - % I ' 11/2• CENTER UPRIGHT - FINISHED FACE OF HEATHER BD &DING' END SEE SECTION 0/13 UPRIGHT 10CCVR5 ONLY ABOVE (RIGHT SHOfN :LEFT OPPOSITE) FIXED SHELF, SECTION ABOVE - FEED WNW - GENERAL NOTES 1. INSTALL ALL TRIM PIECES SHOWN ON THIS SHEET WITH FINISH NAILS - SET NAIL HEADS, 2. EXCEPT FOR 'WALL MOUNTED STANDARDS= ALL CABINET COMPONENTS ARE CORRECTLY SIZED AND ARE NOT TO BE CUT ON SITE. N /1' - LATTICE PANEL : (SHOULD 01 TIGHT TO STANDARD IN UPRIGHT AT EACH 01001 • ADJUSTABLE INTERIOR SHELF W CLIPS 11 PER SHELF) 3. TOUCH-UP PAINT I8 SUPPLIED WITH CABINETS. GENERAL CONTRACTOR IS TO PAINT ALL EXPOSED CUT. ENDS OF TRIM USE BEST JUDGEMENT IN OBTAINING SAME DISTRESSED FINISH AS ADJACENT SURFACES, GYP. BOARD WALL 1' /1111111 SECURE UPRIGHTS TO PLY400D WITHIN WALL OF 7 RA RE R AP R Z 9 i 996 PEWIT OvFIEA CT Gf`AIE UPRIGHT- PLYHD GROUNDS �. . CENTER UPRIGHT FACTORY MULLED >a - STANDARDS ITYP (RIGHT SHOWN LEFT - :7� /] 'T� ,' I/2 ,. ¢ OF UPRIGHT FACE O ALIGN WITH BUTT JOINT IN 053 CABINET BELOW EDGE OF UPRIGHT FACE TO ALIGN IFLVSHJ WITH FINISHED 001 OP BABE CARNET BELOW TOP / COIL SLAB III -/ �{ -II . CONTINUOUS FULL LENGTH OF SUPPORT PLATFORM - D (� �� P • Body ll (.� a ✓�/ F orks THREE 091770 PARNNgY COLUMBUS. OHIO .30 614 - 479 - 7000 BASKET AREA DETAILS 1 SUPPORT PLATFORM BY GC. ] ._3 1/1 CONTINUOUS 2 x 6 FRONT AND BACK ILA 2 x 4 SPREADERS FINISHED FLOOR SEE 'FINISH FLAN' - 10L11ON'E BIELVE6 - DETAIL CABINET UPRIGHTS SOUTHCENTER MALL WEE AT EACH END AND 10'0.0. BET NE N RUN 0006 TO P GROUNDS WALL SECTION THRU BASKET AREA SEATTLE, WASHINGTON 41,4.E 031298 3• = b' °717°6 6116 AS NOTED IONS % I NRWR MO 7.3 • DETAIL � � DETAIL 3 (.WF.D • ASTERN( INDICATE. NO NEVNION 161E TO 7110 6611 METAL 8T008 REFER TO "CONSTRCTIO PLAN" F0143125 INSTALL GYP. BD. ON THIS FACE OF STUD WHEN RECD.- REFER TO THE CONSTRUCTION PLAN.' TOP. 2 X 6 BLOCKING TOP. /.SLAB HOLLOW METAL FRAME (SUPPLED BY GO) SECURE AT FLOOR AND HEAD. 455918000 *000 DOOR - (SUPPLIED BY OWNER) SEE 0005 SCHEDULE' AND DOOR . ELEVATION PAINT MTL FRAME =OIL BASE PAINT FRAME FASTENER AS NEEDED ALIGN TRIM. FLUSH 11TH METAL FRAME '- 3/4 PREFINISHED ND. TRIM RIPPED DOWN FROM 3 /4x 2 I/2" BOARD BY GC INSTALL WITH FINISH NAILS ( SET NAILS ) 3/1' X 2 V2' PREFINISHED HD TRIM - BET IN MASTIC FASTEN WITH FINISH NAILS 15ET -. NAILS,. REFER TO 'ELEVATION OF DOOR TRIM FOR NAIL LOCATIONS. 000R JAMB WALL SECTION THRU VERTICAL WEATHER BOARD SIDING DETAIL IMPORTANT NOTE FRAME MUST BE SET TO FIT TIGHT TO TOP OF HNISHED FLOOR - - ALLOW NO OPEN GAPS DETAIL 1 6 5 FRAME FASTENER AS NEE ALIGN TRIM FLUSH MTH METAL FRAME 3/1 PREFINISHED W0. TRIM RIPPED DOWHFROM 3/4 1/2' BOARD BY GC. INSTALL KITH FINISH NAILS 1 SET NAILS 1 /8 3 5/B MT FOR ADDITIONAL INFORMATION REFER TO OIL. H /8.1. DOOR JAMB DETAIL DETAIL DETAIL REFER TO REFLECTED • CEILING PLAN P REFINISHED VERTICA NEATHF BOARD 5101X0 - NOTES I) AND 3 HORIZONAL CING TT "00 SEE NOT � AND B FLOORING - REFER TO 'FLOOR AHD WALL FINISH PLAN' I21 3 5/8 METAL STUDS FASTEN TOGETHER SECURE TO FLOOR SLAB AND HEADER GYP. BD. TYPE 'X' ON METAL STUDS. WEATHER BOARD 5101NG LINE OF BASE BELOW CONTINUOUS PLYWOOD FURRING. SCREW TO METAL STUDS 15CRIBE TO FIT AGAINST METAL DOOR FRAME/ AND TRACK CONT. VERT. BLOCKING (SCRIBE TO FIT AGAINST METAL DOOR JAMB/ 3/1" X 2 I/2 PREFINISHED D. TRIM - SET IN MASTIC. EN WITH FINISH NAILS. ISET S). REFER TO "ELEVATION OF DOOR - ' FOR NAIL LOCATIONS. 031255 8.1 052296 8.1 8.1 'GENERAL NOTES :' /O VERTICAL WEATHER BOARD SIDING I8 PREEN/SHED (DISTRESSED RED N COLOR I NO RANDOM WIDTH WITH LAP JOINTS, AND IS PROVIDED BY OWNER AND INSTALLED BY GEN. CONTR. ' • O2 WEATHER BOARD SIDING IS SHIPPED TO JOB SITE A8 SINGLE BOARDS, 9 *0' N LENGTH. REFER. TO SPECIAL NOTE BELOW. O3 AU. WD. BABE AND TRIM BOARDS ARE PREFINISHED 1 TO MATCH WEATHER BOARD SIDING 1 , ARE PROVIDED BY OWNER AND ARE INSTALLED BY GEN CONTR. -.. © OWNER SUPPLIES PAW TOUCH • 1 P KR W1111 WEATHER BOARD SIDING, WHICH INCLUDES PANTS AID FRESH WAX. OEN.. CONTR. TO APPLY ONLY TO EXPOSED CUT ENDS, FOLLOW INSTRUCTIONS SUPPLIED WITH KIT, GEN CONTR. TO USE BEST JUDOENENT N TRYING TO MATCH ADJACENT DISTRESSED COLOR WEATHER BOARD SIDING INSTALLATION INSTRUCTION NOTES REFER TO DETAILS ON TIES SHEET FOR REFERENCE. O WEATHER BOARD 8DINO IS TO BE INSTALLED A8 LOOSE BOARDS. 2 CONTINUOUS PLYWOOD FURRING • SCREW TO METAL STUDS AT W 0.0. N 556509 HORIZONTALLY G VERTICALLY. RUN FILL WIDTH BEHIND ALL WING, FROM TOP OF BASE BLOCKING TO O WHEN INSTALLING 8NG15 SIDING BOARDS, G.C. TO MAINTAIN A RANDOM WIDTH AND LENGTH APPEARANCE. DO NOT PLACE TWO BOARDS OF THE SAME WIDTH SIDE ' BY 810E. DO NOT ALIGN HORIZONTAL BUTT JOINTS N ADJACENT VERTICAL BOARD RUNS. 4 BET 8DM0 BOARD AGAINST PLYWOOD FURRING. USING 12) FRESH NAILS AT EACH END OF SIDING BOARD. SECURE SIDING TO THE FURRING. FINISH NAIL THE REMAINDER OF 8RIING BOARD TO FURRING USING FINN 'NAILS AT W 0.0 IMAKIMUMI. CONCEAL BOTTOM HAILS BEHIND THE WALL BASE.' SET ALL NAIL HEADS. © HORIZONTAL BUTT JOINTS IN SIDING ARE NOT TO OCCUR WITHER 20' OF CEILING OR WALL BABE. BUTT ENDS OF SIDING BOARDS TIGHT TOGETHER. EACH BOARD END I8 TO BE FINISH NAILED INTO FURRING USING (2) NAILS (TYPICAL/. SET ALL NAIL HEADS. O PLACE ADHESIVE ON FACE OF 288 BLOCKING AT FLOOR. SECURE P5EFNIB9ED WALL BABE IN PLACE USING FIMSH NAILS. SPACE NAILS AT APPROXIMATELY 24' 0.C. AND' AT ENDS, SET NAIL HEADS. NOTE: O.C. IS TO SET DOOR SO DOOR TRIM FACES THE SALES AREA. NOTE: LOCATE ALL HARDWARE POR A LEFT HAND OR RIGHT HAND DOOR - REFER TO CONSTRUCTION PLAN' FOR DOOR SWING. PREFINISED DOOR KICK AND PUSH PLATE SUPPLIED BY OWNER AND INSTALLED BY GENERAL CONTRACTOR. G.C. TO SUPPLY / INSTALL DOOR CLOSURE. HINGES. DOOR STOP /HOLDER 1 NON -SALES PULL PLATE. REFER TO DOOR SCHEDULE FOR DESCRIPTION ON SHEET 1.1 C PREFINISHED V I METAL KICKPLATE - LOCATE ON SALES O. EO.-LL 51DE ELEVATION OF SALES /NON -SALES ' DOOR (LEFT /RIGHT) 011695 3/4" X 2 I/2' PRE - FINISHED W0. TRIM PREFERRED FINISH NAIL LOCATIONS MP/ NOTE: ET ALL FINISH NAIL HEADS DETAIL DETAIL E0. PREFINISHED WHITE- . WASH DOOR AND TRIM (*REINSTALLED 3/4' HALF ROUND TRIM HAM, PREFINI51180 METAL PUSH PLATE (PULL PLATE ON NON -SALES SIDE IN SAME LOCATION/ HNISH NAIL LOCATIONS EQUALLY SPACED TYP. 1 CUT AND BUTT HD. WALL BASE TIGHT TO HD. DOOR TRIM 8.1 ELEVATION OF SALES /NON -SALES DOOR WOOD TRIM 072296 SCRIBE TIGHT TO CLG. CONT PLYN000 PURRING 1 TYP ) SEE NOTES fl) PANT BLOCKING P -2 BEFORE INSTALLING HEATHER BOARD BIDING FINISH NAIL. END OF WEATHER BOARD SIDING SEE NOTE: p CONT 3,6 BLOCKING 1 SCREW TO EVERY STUD/ FNISN MAIL END OP NEATHE BOARD BIDING 6E5 NOTE 69 3/4•,0 0'. PREFINISHED HEATHER: BOARD BASE, p -� SCRIBE 0)0 T TO FLOORING 1 11 SEE NOTE 6 ! �/� L 1 \ FLOOR VARIES - . 1 SEE FLOOR AND HALL FINISH PLAN 1 FACE 0 WALL BASE BELOW CONTINUOUS PLYWOOD FURRING - SCREW TO STUD FINISH NAIL WEATHER BOARD DONE TO FURRING SET NAIL HEADS ARRANGE FRAMING MEMBERS AS REQUIRED FOR FASTENING FURRING MEMBERS (TEA CONTINUOUS. PLYN00D FURRING - SCREW TO STUDS SECTION AT WALL/CLG. EXTEND FINISH FLOORING UNDER BASE ITYP SECTION AT WALL /BASE DETAIL COORDINATE W/ FRAMING' SO THAT METAL STUD.BLOCKING IS FOR FASTENNG FURRING MEMBERS PPAINT. NOTE :1 SIDING END CONDITION USING PAINT KIT SUPPLIED KITH SIDING AND TRIM, PAINT'EACH 'CUT EDGE OF WEATHER BOARD SIDING OR WALL BASE PRIOR TO SECURING INTO PLACE RIP WEATHER BOARD 5101NG SQUARE TO.REMOVE LAP JOINT 1 - AND CUT WALL BASE SQUARE - BUTT, CUT EDGES TIGHT TO CABINET UPRIGHT. DETAIL b" INSIDE FINISH NAIL WEATHER BOARD SIDING TO FURRING - SET NAIL HEADS RIP WEATHER BOARD SIDING 50UARE I TO REMOVE LAP JOINT 1 - AND CUT HALL BASE SQUARE -BUTT CUT EDGES TIGHT TO ADJACENT PIECES. 'PAINT NOTE : CABINET UPRIGHT FACE OF WALL BASE CORNER DETAIL BELO DETAIL 031298 8:1 03165 8.1 USING PANT KIT SUPPLIED WITH SIDING. AND TRIM. PAINT EA OJT EDGE AND I OF BACK SIDE OF HEATHER BOARD SIDING OR WALL BASE PRIOR TO SECURING INTO PLACE. GYPSUM BOARD WEATHER BOARD SIDING CONTINUE HEATHER BOARD BASE Y /1' w 6' FATHER BD. BASE CONTINUOUS PLYH0012 FURRING SCREW TO STUD FACE OF WALL BASE BELOW INHERE OCCURS) SURFACE MOUNTED PEA -STAN PINE BASE 082265 8.1 031298 INSIDE CORNER BASE DETAIL NO SCALE DASH LINE INDICATES THAT WALL COVERING EXTENDS BENNO BABE A MINIMUM OF 3 IS GA SHEET METAL BLOCKING 60I5RE REDD1 SCREWED TO EVERY' (ALL STUD s 12' OC EXTENDING FROM TOP OP SLAB TO STORE CEILING. REFER TO CONSTRUCTION PLAN FOR LOCATIONS B' 20 GA METAL STUD BLOCKING RUN BETWEEN AND FASTEN ENDS TO - WALL STUDS AND TRACK AT FLOOR 3/4" THICK PREFINISHED PINE WOOD 01440 E SCRIBE 0 TIGHT TO FINISH - FLOOR: SET IN MASTIC I SCREW TO STUD BLOCK'G - SET SCREWS AND PUTTY HOLES SCRIBE 3/1' HD. TEA -STAIN PINE BASE TIGHT TO WEATHER B0. BASE DETAIL SECTION THRU BASE 1W SEE CONSTRUCTION PLAN 3/4' PLYWOOD BLOCKING. 3/1' X 6' PRE- FINISHED B.ASE SCRIBE TIGHT DIM. VARIES TO FLOORING COLUMN DETAIL CO MN CORNER DETAIL PATTERN NOTE; STAGGER JOINTS IN RANDOM PATTERN. DO NOT LOCATE JOINTS NEN THER. AL40, REF ER TO TO NOTE ONE A g3 1' PREFINISHED HEATHER B• :RD SIDING. (SINGLE BOARDS) SET MASTIC ADHESIVE ON PLYNO•. BLOCKING. USE A MINIMUM A'+ NT OF FINISH NAILS TO SECURE 'LACE WHILE ADHESIVE SET 'PAINT 607E : I 8.1 USING PAIN KIT SUPPLIED WITH DON. AND TRIM PAINT EA. EDGE AND I OF BACK 50 OF WEATHER BOARD •LNG OR WALL BASE PRI• TO SECURING INT• 'LACE. FIN/ ' NAIL WEATHER BOARD -. •RIG TO BLOCKING - E T NAIL HEADS RIP WEATHER BOARD DOING SQUARE 1TO REMOVE LAP JOINT) - AND CUT WALL BASE SQUARE - BUTT CUT EDGES TIGHT TO ADJACENT PIECES. IONE EXPOSED SIDING EDGE PER SIDE OF COLUMN, 3/1' PLYWOOD BLOCKING. SCREW TO ME.. STUDS SUPPLED I INSTALLED BY G CONT. 2 BLOCKING CUT TO FIT I SCREW TO EVERY STUD) SECTION AT COLUMN DETAIL MISCELLANEOUS DETA 8 SOUTHOENTER MALL SEATTLE, WASHINGTON 50.1• IWe AS NOTED SC RIB- IGHT TO CLG. `EXTEND FIMSN FLOORING UNDER BASE MP" 03 12 DETAIL T APR 2 91996 PER467 CENTER DASH LINE INDICATES WALL COVERING WHERE INSTALLED) — FLOORING VARIES - SEE FLOOR AND NALL FINISH PLAN 012588 8.1 012898 Bath & Body Works THREE L00EO PARKWAY COLUMBUS, 01110 43230 614 -479 -7O00 INSIDE CORNER DETAIL r•N•RU DETAIL DETAIL IV — SEE NOTE O SCREE VERTICAL EDGE OF WEATHER BOARD SIDING AND WALL BASE TIGHT TO AOJAC5NT NALL SURFACE FINISH NAIL WEATHER BOARD SIDING TO FURRING SET NAIL HEADS B CE OP HALL BASE FLOW WHERE OCCURS) FINISH NAIL WEATHER BOARD SIDING 70 FURRING SET NAIL HEADS RIP HEATHER BOARD SIDING SQUARE 100 REMOVE LAP JOINT) AND CUT WALL BASE SQUARE BUTT CUT. EDGES TIGHT TO ADJACENT PIECES. 'PAINT NOTE :' USING PAINT KIT SUPPLIED WITH SIDING AND TRIM. PAINT EA. CUT EDGE AND 0 OF BACK EIDE OF WEATHER BOARD 80190 00 WALL BASE PRIOR TO �y����pDTNGp SECURING INTO PLACE. 'VUTSIDE CORNER DETAIL 3' -I' -O" AUNT TOP 02" OP PLYWOOD P -2 BEFORE INSTALLING WEATHER BOARD DOING FINISH NAIL END OF WEATHER BOARD SIDING SEE NOTE 1 0 MAI NAIL WEATHER BOARD SIDING TO PLYNOAD BLOCKING - SEE NOTE 1 3/4' X 6' PRE- MIMEO BASE SCRIBE TIGHT TO FLOORING FLOOR VARIES - E FLOOR AND FINISH PLAN' • ASTERISK SNNCATER NO RNVISION NME TO TINY RIQT 8.1 091288 D 03 1296 8.1 m � ::.. UA CONTINUOUS 2x6 BLOCKING CONTINUOUS 3/1' BLOCKING BY G.C. SECURE PERIMETER PIE HOLD O _ - CONTINUOUS 40C; 1x6' HOOD 6KING - SCREW TO EVERY VERTICAL STUD _ : BY G.C. SECURE PERIMETER E ANGLE TO THIS PIECE. CE. HOLD ANGLE G 1' DOWN FROM BLOCKING Tx 2' LAY-IN f - t L _ �® GEN.CONTR.. T• DETERMINE TION TO MALL MOT TO ECKI VE :4%W O.C. 11 3 - /B' METAL STUD I� -. CEILING TILE REFER TO 2 x 2 TEGULAR LAY -IN CEILING GEN. CONTR. TO DETERMINE SOL CONNECTION i0 MALL STRUCTURE ABOVE - (NOT TODECK) REFLECTED CEILING PLAN' DOWN PROM BLOCKING REFER TO • nxr ELE LOCATED A CTION =BOX _ TO BE LOCATBD ABOVB VARIES tt• IM 3 5/8' O MT STUDS • 11' C. 2'x 2' LAY -IN CEILING TILE ®® Orj AMNG • 16' KENO END OF ANGLED METAL METAL STUD AND SECURE TO VERT. STUD ' CEILING BRACE BOX AS REFER TO I 3 5/e' x 20 GA LATERAL METAL STUD BRACING AT 18' O.C. MT) REQUIRED SLIGHTING PLAN' - REFER TO 'CEILING PLAN' 6 /B GYP. BOARD I IIIN IW , V �': i Fi " y II�{I111N111� REFLECTED CEILING PLAN' I ®, <tt JP, 9 ~ t. ''41.111: REFER TO .moo APPLY ADHESIVE :BETIEEN BLOCKING/ GYP BO AND BLOCKING/ BEAM ITV./ � •yy6 T CONTINUOUS 2x6 1000 BLOCKING r• CE LING PLAN' GYP ALIGN EDGE OF ' LIGHTING FIXTURE ✓TOP OFPREFINISHED CAB NEi VALANCE �� ,.,.� � md REFER TO PAINT f3] PENDANT FIXTURE - REFER TO 'LIGHTING 6/8' GYP. BOARD 'CEILING PLAN' H 6/8' GYP. BOARD ON .3 5/8' METAL STUD FRAMING PAINT 3 6/S' MTL STUDS "• 21 OC \ PIECE DECORATIVE REFER TO A PAINT 11 BEAM PROVIDED BY BUTT SOTTO OF OHNER, G.C. TO INSTALL BEAM TIGHT TO ONNSITENISN NAILS. SET GYP. BD HEADS (CUT TO LENGHT <-A 5 /B' GYP. BD TYPE 'X' REFER TO 'REELECTED REFLECTED �_�I POWER TRAC I HEADS -/ REFER TO REFLECTED CEILING' /LIGHTING PLAN' 3 fi /8' METAL STUD FRAMING 116' O.C.) CEILING PLAN ���� M :ii !L x I® PLAN' ) AS SHOWN CONTINUOUS 2x6 W000 CKIXG SCREW TO BIO EVERY - VERTICAL STUD I /2' (RUN TRAC FULL LENGTH - 5' DECORATIVE OF TROFFER) yA•1REFER TO Y'CELNG PLAN' 5/e' GYP BOARD ON SUSPENDED METAL FRAMING TRANSITION '. THRU PREFINISHED S BEAM PROVIDED BEAM BY OWNER. G.C. TO INSTALL FACES : USING D FINISH NAILS BET HEADS. (CUT TO LENGTT ON'91TE1 SECTION THRU CEILING TRANSITION AND PERIMETER BEAM BAC KWRAD ALL AWAY FROM °REPRO NT PAINT® SECTION @ CEILING CABINET ABINET VALANCE ') CEILING PLAN' - SECTION THRU LIGHT TROFFER CEILING MOUNTED PENDANT LIGHT DETAIL . S 6/8'GYP. BO TYPE X' SECTION' THRU CEILING TRANSITION AND PERIMETER BEAM 0220 022095 071894 031296 031298 TAIL 8.2 DETAIL 8.2 DETAIL 8.2 / DETAIL 8.2 DETAIL 8.2 - - ZINC ANGLE TYPE MONOLITHIC DIVIDING STRIP BY: MANHATTAN AMERICAN TERRAZZO - STRIP CO. OF STALEY. NORTH CAROLINA (PHONE: 91/622 -42471 OR :' OWNER APPROVED EQUAL SUPPLIED "- AND INSTALLED BY GEN. CONTRACTOR IMPORTANT NOTE:: ALIGN TOP OF BOTH FLOORING MATERIALS 4/ TOP OF ZINC DIVIDER STRIP', Z INC ANGLE TYPE MONOLITHIC DIVIDING STEP =Y: MANHATTAN AMERICAN TERRAZZO STRIP CO. OP STALEY. NORTH CAROLINA (PHONE: VI/622-120 OR: •INER APPROVED EQUAL SUPPLIED AND I TALLED BY GEN. CONTRACTOR IMPORTA NOTE ALIGN TOP ; BOTH FLOORING 000551* H / 'TOP OF 2 DIVIDER STRIP 000 LOOENG, M' FLOORING NOTE ALL DECORATIVE BOX DEERE ARE - PREMISED NO SUPPLED BY OWNER. RIO INSTALLED BY OWL CONTR.IALL BLOCKING FOR BEARE W SUPPLED BY GEM. CONTR.1 I DEC ANGLE TYPE MONOLITHIC DIVIDING STRIP BY: MANHATTAN AMERICAN TERRAZZO STRIP CO. OF STALEY. NORTH CAROLINA (PHONE: N9/622 -13411 0R. OWNER APPROVED EQUAL SUPPLIED AND INSTALLED. BY GEN. CONTRACTOR IMPORTANT NOTE BUTT BEAMS TOGETNER AS 0HOWN' BUTT JOINT (TYPICAL) PERIMETER BEAMS _ - �' r2 AND UNDER TO RECEIVE NO SPLICE D - AND OVER IN LENGTH TO BE SPLICED IN EQUAL SECTIONS IAN LENGNTH 4-47' NITH MMIMUX NUMBER OF SEAMS AS POSSIBLE C (TYPICAL EA. DIRECTION) 1 ALIGN TOP OF BOTH FLOORING MATERIALS W/ TOP OP ZINC DIVIDER STRIP "� CERAMIC TILE O R WOOD FLOORING PAVER FLOORING MALL FL OORIN G ®" W 000 FLOORNG lb y W I " % ;1Yid' 7 1/41,1111 l,l- ' '�. mxn:w FOHY RAC"""... - ADJUST BOTH GO. TO ADJUST 4041= SETTING BED TO ACHIEVE (LUSH TRANSITION GC TO ADJUST SETT 0E0 UN - HOOD FLOORING TO A= (EVE FLUSH TRANS 1' ON BUTT PLOOk ETTI SETTING BED UNDER EA FINISHES - TO 1 • ® FLOOR MATERIAL TO 'ZINC STRIP 10 ACHIEVE FLUSH TRANSITION NO GROUT JOINT LASH DOWN TO EXIST FLOOR SLAB SLOP TO BE 1/16 IN O MAX FRONT OF STORE �, REVIEW SPECIFICATION& DIVISION IX 'FINISHES'. FOR FLOOR FINISH INSTALLATION REVIEW SFECIPICATION9 DIVISION. IX 'FINISHES' FOR PLOORFINISH INSTALLATION BUTT BOTH FLOOR 010164E5 TIGHT. T0 ZIN STRIP - NO CAULK JOINT REVIEW SPECIFICATIONS DIVISION IX 'FINISHES' FOR FLOOR FINISH INSTALLATION �- �. PERIMETER BEAMS LAYOUT WOOD - TO. PAVER TO MALL 'FLOORING.. VINYL TO WOOD TRANSITION WOOD TO MALL FLOORING NO SCALE '. 011865 N - 031988 000785 10109 DETAIL 8.2 DETAIL H' 8.2 DETAIL J 8.2 DETAIL 8.2 'ZI 4E TYPE MONOLITHIC DIVIDING STRIP BY: MAN• AN AMERICAN TERRAZZO STRIPC•. "TALEY: NORTH CAROLINA - • (PHONE: 119/6 OR:. OWNER APPROVED EQ: - IMPLIED AND INSTALLED BY GEN. CONTR' •: IMPORTANT NOTE: ALIGN TOP OF 4000 FLOORING MATERIAL N/ TOP OP ZINC DIVIDER STRIP BY THE C8. GROUP WI -800- PROVIDED 1 INSTALLED BY (CONSULT W/ OWNERS CONSTRUCTION FOR SPECIFICATIONS/ - W000 FLOORING SEE FINISH PLAN' G.C. TO ADJUST SETTING BED TO ACHIEVE FL TRAN :� , 233 -8.PB GC. MGR. EPDXY FILLER ILATAPDX OR 5 - 3 SUM E 5-300 0.31.1 ER TO NOTE' ON 9ENSORMATIC DETAIL) WOOD FLOORING SEE FINISH PLAN -- SEE DTL. M /82 I .. of 4 °0 Cp ILOCOMAT I WOOD F LOORING y v FLASH DOWN TO EXIST. FLOOR SLAB SLOPE r0 BE 1/16' IN I'-O MAX. - GC TO ADJU EETTIN TO ,. A 'EFLUSH RANSITION. ..„ CONCRETE 5 '- REVIEW SPECIFICATIONS DIVISION IX 'FINISH • •R FLOOR FINIS nLLATION BUTT BOTH FLOOR FINISHES TIGHT TO ZINC STRIP - COCOMAT INSTALLATION DE NO CAULK JOINT �68G TO WOOD TRANSITION '•0 ✓/ x.TS. 031988 DETAIL 8.2 DETAIL N 2 QR pVE Ea FM D,f LAW F P EN APR G 2 9E1996 BWrcENTER BBath /��" R a �J C& 11 `^ " o U J W MFEE LINKED PARKWAY MINIBUS. OHIO /NW 614 - 429-1000 MISCELLANEOUS DETAILS N WASHINGTON SEATTLE, .M,a .R X8.1. � *5 *9 AS NOTED 1-N-15 RDO 8.2 re F.Q • ABTER9E •EIIOATE9 NO MYMIN. NAOE TO 1MB MEET . NOTE: THEM PLANS ARE FOR FIXTURE AND GRAB BAR ILLUSTRATIONS; FOR EXACT ROOM SIZES, WATERCLOSET A o ' ''CONFIGURATIONS AMI DOOR SWINGS : -REFER TO TIE 'CONSTRUCTION PLAN. - ' ) DASHED. NNE INDICATES TOP OF WALL TILE. USE WATER COOLER NOTE: IF TXE WATER COOLER IS LOCATED W THE PATH OF TRAVEL, A TEXTURED AREA T -0• AROU TXE FOUNTN, CLEARLY IDENTIFIABLE ND AI BY THE BLIND IB REQUIRED. BUBBLER 18 70 SE ACTIVATED U ARE BY A HANDICAP FURS E TO FRONT FACE CE OF OF UNIT. WATER COOLERS AR TO BE _ LOCATED WITHIN ALCOVES 80 AS NOT TO BE IN THE CORRIDOR OR WALK. COOLERS MUST BE APPROACHED FROM THE FRONT. 54' (MIN) OB 5 NK O- 3' (MIN.) ; ? TILE ONLY IF REQUIRED AIRHORRIES - AU LORAL SUIL� TILE TO - LE BE B x TLORIEA TI - -- LIBERTY TILE' NA SERIE 3 PEARL ' . TOR EQUAL) QUAL) 860 S/ NATURAL O . °. R' O NEW 24" X 24 FLOOR SERVICE SINK WI \UCET S 0 INCLUDE 4T HOSE ALI n ) I a- 1- 19/5E0969 • L - - =A I »>III 12 y=J. I .9£ - m ® / / F- 48 lMIN) r � '1I - u VATO fiY INCRF/SES IN SIZE OTHER TH 1 O GENERAL (MIN.) ONTRACTO HANDICAP • 1 ■'� O ■ I I ■I T m - I. A � S REOU REMEN15 2 I SHOW NIA. M GRAB BAR REFER TO -DEDUL A - 5/9.1 '. MUST COMPLY WITH O LOCAL AND STATE COD 03 5' -0 HANDICAP TURNING DIAMETER TO BE PROVIDED IN HANDICAP LAVATORIES. ® HEAVY LINE INDICATES EXTENT OF MARUTE I . ON WALL: SE A B O VE TOP OF SERVICE SINK 0 AND If (MIN.) BEYOND EACH SIDE OF SINK. CAULK AT MARIITE /SINK AND SINK /FLOOR WT WHITE SILICONE CAULK. , OS SERVICE SINK STORAGE SHELVES. GENERAL CONTRACTOR TO FURNISH AND INSTALL (5) 16' DEEP ADJUSTABLE PLYWOOD SHELVES - REFER TO DETAIL G-2/9.1 . ©. LAVATORY STORAGE SHELVES: G.C. TO NRNSH AND INSTALL (2)T6" DEEP 'ADJUSTABLE PLYWOOD SHELVES TO BE 30' LONG WITH CLIPPED CORNERS REFER TO DETAIL G- 1/9.1. O GENERAL CONTRACTOR TO PROVIDE AND INSTALL A CLOTHING HOOK MOUNTED AT 44' A.F.F. SO BE ALUMINUM OC 5000 BY BUILDERS BRASS WORKS (OR EpUP1) MOUNTED TO SOLID IN -WALL -WALL BLOCKING. - �: GROUT 1 (dAll RYP.1 \ FLUSH HANDLE NUST BE ON SIDE OF WATER CLOSET' ® ®® {L e e L' '• q � pp z T ' I A \� O - • 4. Q'® . 10 - 9 oti . CXY•1 .4E z 1 (NINI bC IXYNI .•£ • WALL. STANDARDS ®® ? G•® ® l -I - - ' � L IB • 21' 0.0 ' 1 _ 1 iVno31.9 ® ` " 'OPEN' !111011111.191111® �- 1 - TP ' TOP 0F 0 O T 0 . EV TOILET SEAT en EVATION I ELEVATION '. L ® GLASS MIRROR - 1S x 38 x 1/4" PLATE GLASS MIRROR (ALL EDGES OF MIRROR TO RECEIVE SLIGHRY CURVED EDGE WITH SMOOTHED O R FINISH) WITH TOP AND BOTTOM 'J NV CHANNEL N T 8 N:T.S,. (SET MIRROR IN FULL BED OF MASTIC) PROVIDED AND INSTALLED BY G.C. MOUNT BOTTOM - - up N.T.S. 48' (MIN.) ' OF MIRROR AT Mr A.F.F. ANO CENTER ABOVE SINK EQ. 09 GLASS MIRROR -' 20" K 58 x l /4' PUTE GLASS MIRROR (ALL EDGES OF MIRROR TO R ECEIVE SLIGHTLY CURVED EDGE WITH SMOOTHED OR POLISHED FINISH) WITH TOP AND BOTTOM • 1 CHANNEL (SET MIRROR IN FULL BED OF MASTIC) PROVIDED AND INSTALLED BY G.C. CENTER AND MOUNT REFER TO ON LAVATORY SIDE OF DOOR WITH TOP /MIRROR o ]0" AF F. A rygX. GRAB SATE NOTES- '_ - KINK NOTES' GRAB BERN SHALL NOT ROTATE AND INSULATE OR COVER ALL HOT WATER ' THERE ARE TO BE NO SHARP, OR MID DRAIN PIPES WIDER SINKS. NO SOLID „,, ABRASIVE ELEMENTS ON OR SHARP' OR ABRASIVE SURFACES IN-I4ALL ' ADJACENT TO THEM EDGES ME TO ALLOWED UNDER ERNS. I BLOCKING HAVE A MNIMUM OF I/8' RADWB. . 'DOOR SCHEDULE' - - 10 PREFINISHED METAL CORNER GUARDS SUPPLIED BY OWNER AND INSTALLED BY G. C. FOR 'HARDWARE 0 MOUNT 1/2' A.F.F. BASE) _ — _ _ _I N BOTTOM OF GUARD AT (OVER NEQUIREMENTS GENERAL CONTRACTOR TO INSTALL THE FOLLOWING OWNER SUPPLIED ITEMS: .. WHICH WILL ARRN£ ON MERCHANDISE TRUCK PROVIDE SOLID IN WALL BLOCKING FOR ALL OF THESE ITEMS. N.C. LAV /SINK /SHELVING ILLUSTRATION , , SECURED '^ FAUCET CONTROLS AND OPERATING TO STUDS -' GRAB BAR BACKING AM ATTACHMENT MECHANISMS MUST BE EASILY - SHALL BE CONSTRUCTED FOR A 250 OPERATED BY ONE HAND AND MUST NOT ' ' POUND POINT LOAD. REQUIRE GRASPING, PINCHING, OR a D LE.A R x \ WATER COOLER ILLUSTRATION - I /2' DID N.T.S. TOILET PAPER HOLDER 103 FRICTION - TYPE MOP HOLDERS �'. . TWISTING OF THE WRIST.' THE (SINGLE AND DOUBLE STRIP) 4 FORCE NEEDED TO ACTIVATE CONTROLS 12 ROLL-TYPE PAPER TOWEL HOLDER 14 FRICTION-TYPE HOSE HOLDER GRAB BAR DETAIL AT' WALL SHALL NOT EXCEED 5 LS$. FOR LEVER 0 — — — -.I FLOOR AREA HANDICAP LAVATORY AND SINK INFORMATION MOUNT AT 1 Y A. F.F. OPERATED OR 15 CBS. FOR PUSH TYPE. - S NTS. . CLEAR REQUIRED AT SINK N.T.5. 011086 DETAIL, a.■ - - 1 -'.•. .. IMPORTANT N OTE. UPON COMPLETION OF PROJECT GENERAL CONTRACTOR MUST RUN A NEW BLUEP INT SET FOR THE COMPLETED STORE DRAWINGS (ARCHITECTURAL, MECHANICAL AND ELECT ICAL) AND PLACE BLUEPRINTS INTO THE PUN TUBE HOLDER. I/1' OI THOU BOLT P. BD. 1/ TOGGLE OGLE (T ITYP. OF 21 PAN HEAD SCREWS TO SECURE \ 2' POLA 3/4' x 2' POPLAR ' _ �J "' 1 111 I SCREWED 4 METAL S NOTE. IA WOOD TRIM TO BE IIHITE PINE, 22 MINIMUM. KNOTS WILL BE NO CLOSER THAN IB'. ITYP. O 2) 3 x 4 6' METAL STUD CONTINUOUS BETWEEN VERTICAL WALL STUDS WALL FRUO - LEE CTO 5 /B' GYPSUM BOARD LANDLORD APPROVED WATERPROOF MEMBRANE. FURNISHED 1 INSTALLED BY O GENERAL CONTRACTOR . TURN UP 6' BEHIND GYPSUM BOARD AT PERIMETER � � I PARTITIONS. _ _ r -1I K LOOSE PVC 6 DIAMETER FRAME RUST BE SET TO ,FIT • FLOOR •TO TOP OP FINISHED FLOOR.- ALLOW NO OPEN GAPS II TOP CAP PVC TUBE `✓ 48' A METAL JgSTS fl6') OC NO TE ON I SALES SAP NON -COM. PLYWOOD DECK S L EDGES WALL STANDARD STUD I / ALGN OF ,. HOLLOW METAL D OOR X• AND FRAME - SEE - ,., 5/8' TYPE 'X GYP BD. I — LABEL ® • ,R TUBE /8 ° I _____ SMOOTH MOOTH PAINT P -6 O / x 4 HOOD TMM - RUN EDGE CONTINUOUS F WALL ALONG TOP O WALL 16 GA. NME b A- WALL MP EDGE x CAP AND HORIZONTAL 'DOOR SCHEDULE ,� , , EACH BIDE 3 5 /B' . ;METAL STUD FRAMING AT 16' C. TTYP) I ` 111=11111111 FURRING FLUSH ITYP1 / I1'TI 3/ +' HORIZ. � I \� POPLAR R ENO CAP RUN UN F FROM \ FLOOR TO CEILING ; • ` G SHEASTA4' WOOD FURRING SECURE DOOR FRAM HEAD -AS REQUIRED HI � T PROVIDREM A BEL T,3r1u0 A�► V VINYL COATED LADDR HOO D T RU OUT Y10111.11 EXTENT Of HOOD HOLDER IS NOT TO BE REMOVED THE AND OF THE THE CONSENT OF THE STORE XAXAGER. THANK YOU. �IMIN. HGT) I x 1 RIRE MESH END WALL STUD ® 5 /8' GYP BOARD PAINT 3 5 /B' METAL STUD PARTITION -ALIGN STIES DIRECTLY UNDER -JOIST ITYP.1 ' FASTEN TO STUD ' -' FRAME FASTENER FASTEN TOGETHER FA SECURE TO FLOOR SLAB � • HEADER CONCRETE CONCRETE BLAB — p VL BOTTOM CAP GLUED M PLACE SAND EDGES SMOOTH AS NEEDED - DOOR JAMB DETAIL 16501 PAMY a GYP� OARA H " -a J REFER TO PARTITION NOTES ON SHEET 1.1 POR MORE INFORMATIONOOR ON WALL CONSTRUCTION TUBE ELEVATION TOILET /OFFICE DECK SECTION WATERPROOF MEMBRANE DETAIL E1M1R " • ' ENTRE ASSEMBLY 15 CONSTRUCTED BY GENERAL CONTRACTOR M FIELD. PLAN TUBE HOLDER END WALL DETAIL IN NON -SALES N.T.S. 011695 N.T.S. 1292 3.- I' -0' 090492 3. ° I' -0' 01189 AS NOTED 01279 DETAIL 6 9.1 DETAIL C, DETAIL ® 9.1 DETAIL E 9.1 DETAIL F 9.1 13 qbot iq �.v —� 03‘ w r` p,(,cI' NON•SALES SHELVING AND HANGROD NOTE NON -SALES SHELVING D DETAILS FURRING AND WALL STANDARD INSTALLATION DETAIL L o- Q o clG. o BY TANDARD AND VERY OT ROLE TO THE .11-"3 Ax a ePART. 010 0- 16 mop mur Br GC. O -" 4 LruwoD /+ . �/+ O - INTERIOR ©- BSHELF BRACKETS o Dow cups PROMED © N" D A - 0 NM G C C2)— « To R To LE9 4 RCoilEDT6PADNG O . ee CAS TO D SU STUDS TER E N a ADO Lmociooto mi. SNOB AS iirro. TO BI.E A.'...s n.A a are FOR RwLSTA NKR xD�F� e1D W000 6FLF �, ARES REFER TO DiT a . T-4. I' r , • I H - 4 a0ore ! - I C J 00 I — T Y II SDS BxOS1 .L EXPSED EDGES, .. SHELF o PLAN VIEW �, © � G g € . - T i 0 B A -n MALL elA NDEALY w IACRO TM ward U Fa:, T :nw. FNRRN4 rTeT— --..00,1= � O 11 — III 1 w a LY1100RD eY nub SCREEN M xenxD CLEAR mn ANAAN FURRING IS Uxu F . NOLE iX IN N LATr� e IN aD lwo F 1 ut � eNANO FDALLY TxaT LocAiwx. O s r� — - 1a =� ® SMELWN TYP. MOUNTING VIN - .. V 0 8lCTION MELVNO SHELVING - NON SHELVING AND HANGROD DETAILS e V "" — __�_ '3' OFF) U' 8WK ROOM LAVATORY SHELF END VIEW SSS9 O � CITPN T .. l APR [ , PE00 DIAAAD2 — ,Igs E Pr. T iorl Luau .90 CLIPS pR r e6 R EE ' Ix6FRRRING LT STANDARDS GENERAL NOTES Fe N AMY TAMU OYP DETAILS. D e RnrteeD o ANN o w .. npM n ux C EKES Two ALL .ELF 4021 RS 0130005 AND wu ST ND RD RE INSTAL= BY GC, M4 xARD SUPPLED by a6IER -SALES N:T.S. ` \\ \��w w AND _ Bath Sc Body Works THEE LIMITED RM PARKWAY COLUMBUS, OHIO 43260 814 -419 -7000 NON -SALES DETAILS —_— ROOD RUN co nxU aN> Re 4120 � I I� 1 1 -- �" -�� S MALL LNG .LL MO 6 06 -C O SPLICES AT ALL BEAMS IM B PLUM AVNN SEATTLE, WASHINGTON .M..R . AS NOTED 1 -IF-16 RDG S I6.. Ia..K 9.1 031295 DE (; 9 ToMe.E 6 ASTERISK DMA,. NO 5004401 MADE TO TM SENT • BATH 1 BODY WORKS' PRESENTATION TAKE -OFF LIST GC. HOTF. ALL PRESENTATION ITEMS ARE SUPPLIED BY OWNER. Q,C,_IQT,E; BWC NUMBERS ARE REFERENCED ON OWNER'S GENERAL CONTRACTOR IS RESPONSIBLE TO UNCRATE ASSEMBLE: CLEAN AN0 PLACE ALL PRESENTATION EMS IN SALES AREA. = GC. INSTALLED - REFER TO PRESENTATION DETAILS (SHEET. 1111. INDIVIDUAL WALLCOVERING PURCHASE ORDER. REFER TO FLOOR AND WALL MESH PLAN' AND 'PRESENTATION PLAN' FOR 1 0) ADDITIONAL WALLCOVERINGl91. REFER TO SHEET 11.1 FOR GENERAL INSTALLATION INSTRUCTIONS. CONSULT OWNER'S CONSTRUCTION MANAGER FOR ADDITIONAL INFORMATION. PRESENTATION ITEMS PRESENTATION ITEMS ICONTD.1 ITEM' QTY DESCRIPTION ITEM QTY DESCRIPTION • B -01 � DEMONSTRATION CHALKBOARD SIGN - 38'W X 20 • B -02 --_ STAR QUILT - 48 X 4034 2 5-03 '._ BI -FOLD SHUTTERS - 369 X 6'1'H ' 4G.C. TO ATTACH TO: WALL( • 5-04 SMALL SPICE RACK - 181 X 5 -1/4•0 X 2431 (MOUNTED • 4' -6' TO BOTTOM) • • 8 -05 2 BACKWRAP HANGING SIGNAGE - 24 X 4014 • B -06 __? BACKWRAP 51GNAGE FRAME = 3214 X 1' B -OT 1 MANNEQUIN B-08 13 CEDAR BARREL 1/ LOGO - 15 B -09 I VENDOR CART - 30'1 X 1' -TO B -10 I BLUE DISPLAY HUTCH - 301 X 24'0 B -11 'WHAT'S NEW YELLOW CUPBOARD - 3PH X 16'0 B -D NATURAL LADDER UNIT W/ BASKETS - 224 X 1510 8 -13 = ROCKING CHAIR - 25 * X 31'0 61-11 i ANTIQUE FRAGRANCE FIXTURE'- 4 -6'W X 30 8-15 SMALL WHEELBARROW 8 1 6005E BASKET FIXTURE - 30'4 X 35'0 BM" __ 'CREATE YOUR OWN ...• WAGON - 5 X 2T'D 8216 'CREATE YOUR 01181..• QUILT RACK - 5' -19 X 6'-0 13-20 SQUARE TABLE TOP - 36, X 36'0 8 -21 1 ROUND TABLE TOP - 36 8 -23 1 STANDING FLOOR SIGN - 331: X 6' -8•H 8 -23 = HANGING STOREFRONT SIGN - 36'1 X 36'4 5 -24 — TWO -SIDED EASEL - 26 X 5' -5'H B -25 '-- LARGE HUTCH FIXTURE - 48, X 24•3 X 1-6 "H 15-26 DEMONSTRATION CART - 30'4) X 21 5-21 1 VINTAGE BASKETS - 20'0IA B -26 IMPULSE FIXTURE - 30'1 X 30 • B -30 = WHITE LATTICE PANEL - 33 V2 X 1 IAVG. SIDE, • B -31 SMALL HUTCH FIXTURE - 3931 X 24 X 1 -0•H • 16-33 'LARGE SPICE RACK - 34'0 X 5-1/K0 X 40'4 IMTO. • 4'-6' TO BOTTOM( B- 33____ 2 -TIER BENCH FIXTURE - 42'1 X 10 3AI1COVERINCS /MURALS BEN QTY DESCRIPTION 5 BWC -01 4 PAINTED 4 I /4' RED GINGHAM CHECK WC • 810 -02 --- PHOTOGRAPHIC MURAL NC . B-19 RECTANGULAR TABLE TOP - 6'-011 X 36'0 •BWC -03 — PAINTED 6' GINGHAM WC • 1614604 ( SEASONAL PHOTOGRAPHIC MURAL 14 PANELS /SEASON) i3(16-- of ULL PRESENTATION ITEMS OOP ER PROV350) OWNER METALLED O.C. INSTALLED e - V/ALICOVERNO INSTALL PRIOR TO INSTALLATION OF PRESENTATICM ITEMS) CH THIS WALL (SEE 'FLOOR & WALL FINISH PLAN' FOR EXTENT OF COVERAGE) SCALE: I /4' • r -0• PRESENTATION PLAN PRESENTATION TAKEOFF: SEE LIST ABOVE PRESENTATION DETAILS: SEE SHEET 11.1 Bath -- & Body Works THREE LIMITED PARKWAY COLUMBUS. OHIO 43231 614 -408 -0000 PRESENTATION PLAN SOUTHOENTER_MALL SEATTLE, WASHINGTON scale 8=4)•28 RECEIVED ilAtNN, OW C4 APR 2 9 1996 ♦ ASTERISK N5ICATE5 NO REVISION 3110E TO MS MEET Moo 10.1 Q • -. O O. G.C TO ALIGN SIGNBETNEEN MI DEMONSTRATION AREA CHALKBOARD SIGN PROVIDED OWNER FOR INSTALLATION OH BY GENERAL CONTRACTOR _ ® m 0 © Q •': r • B 0 'STAR' OUST, 'WALL HANGING • PROVIDED BY OWNER PO T . . INSTALLATION BY GEN AL CONTRACTOR . TO INSTALL BASKET AREA SIGNAGE' PROVIDED BY OWNER FOR INSTALLATION BY GENERAL CONTRACTOR K W - ••;. m EDGEBOF PENDANT FIXTURES AS INDICATED BELOW. N.Q.M WALL TO BE PREPARED AND FINISHED REFER TO PRESENTATION PLAN' AS NOTED ON THE F LOOR 1 WALL FOR SPECIFIC ORIENTATION. FNISH PLAN' PRIOR TO ACCOMPLISHING y THE WORK ILLUSTRATED IN THIS DETAIL - '? - f ® �: L..J • _.NOTE. - - O ER PROVIDED OVAL SIGN AT CENTER NOTE. OF TOP SHELF WALL TO BE PREPARED AND FINISHED AS NOTED ON THE FLOOR 1 HALL PLAN' PRIOR TO ACCOMPLISHING — _ BBB Bi — I —I Y ■_ ® I - I —I I I ® I — � I - HALL I6 TO PREPARED AND READY • TO RED ' WALLCOVERING '; .• H QUILT. ALL HARDWARE PROVIDED WITH GC TO PROVIDE' BLOCKING AND INSTALL BRACKETS SO A TO LOCATE QUILT PER ILLUSTRATION. GC TO CONSULT OWNERS CONSTRUCTION MANAGER. AS SOON AS PASSIBLE: IF ADDITIONAL INFORMATION IS NECESSARY OR INFORMATION INFORMATION FROM ACTUAL COND TIONS .. -. F* * * >k * >01 Ik * * :k * >f! 00 l � V � � V F 0 *< V V VJ V V V 0000 .�.yy k V V * * > 1 ��yyJJ..,��yy 000 00 ��y•.>Y 0SA0000 #' V V 00000 4 *3A: 0000000 • I•L WA 00000000 00 °' 00000 0000 THE WORK ILLUSTRATED IN. THIS DETAIL. ® DEM CHALKBOARD SIGN (B OII ®� ®�®�0 ; 11,0 o I - ' � �' I I I ® 1 11 I ®I '.. EQ. ® 1 ® I I I DEMONSTRATION CHALKBOARD SIGNAGE LOCATION 'STAR" QUILT • WALL HANGING BASKET AREA SIGNAGE LOCATION 1/2• =1_O•. 050996 N . T . S . :.. DSO..: I/2 - -1 - 0 - 032996 DETAIL B 0 DETAIL ITEM: B -02 DETAIL HANGING SIGNAGE IB -O6 PROVIDED BY OWNER FORA CONTR 1 INSTALLATION BY GENERAL CONTRACTOR WITH APPLICABLE( HHANGING SIGNAGE FRAME ROVIDED BY OWNER POR INSTALLATION OSTI BY GENERAL CONTRACTOR / % 'J' HOOKS W/ EYES � 1 IBLALK IRON FINIbHI I � 3/4' 6' TRIM --> SUPPLIED W/ FRAME / >w // O.C. A TTAC HE T MOLES BO MUST FIRST BE USING S TO 8BMN0 LIO WREN TO. WEDGE USING BCRIWS.PROV®Ep W/ ANGLES. ..\ , NnTC. WALL TO BE PREPARED AND FINISHED AS NOTED ON THE FLOOR 1 WALL FINISH PLAN' PRIOR TO ACCOMPLISHING THE WORK ILLUSTRATED IN TINS DETAIL PREFIXISHED MOUNTING ANGLES F SUPPLIED W/ FRAME INSTALLED BY GG IT, OF 1 PER TOP OF FRAME) - I - �•li T ] MOUNTING ANGLES — ITVP. OF 31 21' X18' HANGING SIGNAGE - rE0 EC) I' FF d .. I '. mil .9 X .9 /9 -) ,` 1 24'.X e' 1 HANGING BGNAGE (ALTERNATE ORATION) I 1 I • r I_ ; 1 III C 1 I _ 1 C 1 3/4' X 6' PREHNISNED FOAM TRIM BOARD - M�RAFBGRTHIC BUTT SEAM EYONO °' HOLD BACK OF FRAME TIGHT /FLAT TO WALL //�\ / \.. L� y —I—, � HANGING S IB�05) E Ems— ."..-1---,,L,.. HANGING SIGNAGE 0-0S, 1 3 SIGNAGE FRAME 113-061 (— SIGNAGE FRAME 121-06) T OC. NDTF ORB:NT M SBTBO ANGLES AS SNOW O.C, TO PROMS SOLO KWALL 111.0“.10. K111.0“.10. . ED ,. EQ L ALTERNATE LOCAT DN FOR SIGNAGE IB -061 WHEN SP RAIN DOES NOT ALLOW FOR SIGNAGE FRAME (B -061 - `SIGNAGE FRAME PREFINISHED BWC 011 SIGNAGE FRAME L J I� ARANTEB LS TATEMEN REFER TO PRESENTATION PLAN' L l J 1 J I QUIT m . TATEMENT SIGNAGE FRAME ,/ PLAN Of SIGNAGE FRAAE ) • 1 , r ELEVATION BEHIND BAC.KWR 3/4' X 6' TRIM —> ()REFINISHED MOUNTING ANGLES SUPPLIED W/ FRAME INSTALLED BY GC. 3 TYP. OF 2 PER BOTTOM OF FRAME( •1.e (----- - /2'•' - _' ANON 0 1 1 ELEVATION owalGNAoE HANGING SIGNAGE AT BACKWRAP AREA 110 S CALE AS NOTED - .. DETAIL ITEM : B- 05/B -06 NOTE RE ALL NSTRUOTIOIIS BEFORE STARTNO. IBWC -03t PHOTOGRAPHIC MURAL WALLCOVERING SEASONAL PHOTOGRAPHIC MURAL 11 PANELS /SEASON) PROVO E0 BY OWNER FOR INSTALLATION BY GENERAL CONTRACTOR NOTE:. READ. ALL INSTRUCTIONS BEFORE STARTING. • '4 I/4• RED GINGHAM CHECK' N • ERING - PROVIDED BY OWNER FOR INSTALLATION BY GENERAL CONTRACTOR - EL= PHOTO • - -' O MUAAL IS TO BE METALLED 111 O.C. MOP TO THE INSTALL/al OF THE ADJACENT NNE OW CME. INSTRUCTIONS FOR HANGING PHOTOGRAPHIC MURAL : • • I ' • PROVIDED BY OAR OR INSTALLATION - GENERAL CONTRACTOR COLUMN APPLICATIONS ."-1 S.C. IS TO BE RE ELS FOR TIE PROTECTION OF MOTOGRAPpO MURAL +•''. 0 CONSTRUCTION. • A. LAYOUT OF IMAGE WITH NUMBERED PANELS 5 IMAGES SECTIONS R NUMBER ON BACK OF EACH PANEL. C INSTALLATION INSTRUCUC TIONS, INSTAL CATION INSTRVTIONR FOR INSTALLATO INFORMATION CALL TONY OLIVER. TITER 1E-T2W AT 1N OR NL SHEY SCHMITTER, -1313 FOR :, %•ITIONAL INFORMATION CONTACT •. KIS IMAGING PHOGRAPHICS - BOO - 611 -E. OR 1 -3D -201 -1113 09 �. . WHILE MAINTAINING 'PULL' CHECKS ALONG CEILING: NAM CENTER ARTWORK 1610E TO WALL IS TO BE PREPARED AND READY SIDE) ON 'STOREFRONT TO RECEIVE WALLCOVERING. NOE OF COLUMN - AND CONTINUE BT WRAPPING ALL GC. TO CONSULT OWNERS CONSTRUCTION (41 CORNERS AND SEAMING MANAGER, AS SOON AS POSSIBLE. ONLY OBGE ON SIDE OP IF ADDITIONAL INFORMATION IS COLUMN CLOSEST. TO LONG NECESSARY OR INFORMATION DIFFERS DEMISE WALL TRIM BOTTOM BELOW' FULL' CHECK WHICH FROM ACTUAL CONDITIONS: MOST CLOSELY DUPLICATES SIDE WALL INSTALLATION ISEE NOTE BELOW) - A WALL SHOULD SE FREE OP ALL IMPERFECTIONS IE RUMPS. DIVOTS. ET B. WALL MAST NAVE A LIGHT COAT' NTH AN OIL OR ALKHYD BABE P R, RECOMMENDATION SHEILDS. DO PRIME WITH LAYTEX. ' PANEL 0 PANEL PANEL Q 0 PANEL 0 C V pENE R p 10 , N N. R` )0 MNO WI APR 2 9 1996 FFS.Y! CT'NMB STRIP 01 STRIP STRIP ®. Ea 9 DO NOS USE PAST DRYNG PRIMERS SUCH AS Z OR BENZ •• P —.. EQ ' EQ ' STRIP 10 • 1) 00 501 USE SIZING ON THE WALL. C APPLY CLAY BASED VINYL AOHESIV RE. STICK III OR BIMILIARI TO WALL OR BACK OF PRNT WHI VER IS THE BEST FOR YOUR METHOD HANGING VIA ROLLER. IT OT NECESSARY TO LOAD FACE PANELS, BU JJ �1 PLY Ng AS SSARY TO SHIFT IMAGE wI /� • YOU y •�AN4 THE FIRST SECTION OF THE IAAGE. 'Yv : EI BOTTOM ER THAT THE TOP.ROLLING IMAGE E INNER SECTIONS HAVE HO %CASS 1 E LEFT AND RIGHT / 1' EXCESS IMAGE TOP AND BOTTOM OF TIC - - K9 ISEE BELOW'TICKMARKS'.1 WORK OUT ALL BUBBLES AND 8M00 •UT MAKE BORE IMAGE IS SQUARE.. 2) REPEAT PROCEDURE F• ECOND SECTION. KEEP IN MIND THE OVERLAP SECTION ON OVER( LNG SIDE MUST LINE UP. YOU CAN USE THE WHITE VERTC INES AS INDICATORS BUT . - . EYEBALL IMAGE LINES TRIM OVERLA G SECTION ON WALL LAP AND DOUBLE CUT MARKS Foa.TT 1 d ® EEEEEEEE - - - — < TGXT 0 6 RFACET (CHECKS MAT BE CUT AS REQUIRED) • SEASONAL PHOTOGRAPHIC MURAL Sge ' VP ,. E, OI CT A EACH LAYOUT ILL BE A EACH LAYOUERE . WILL INDICATE WHERE PRINTS TRIMMED APPLICATIONS s s 6 Sb.(U9RllE WE 1 /2' =1 -0 .3'OSIMCI'OB� T I—LI. OF VERTICAL SEAM YP. OF 3) EACH SECTION OF PRINT HAS CORRESPONDING WHITE MARKS ITICK81 TO SHOW WHERE PRINTS SHOULD LINER FOR TRIMMING 5' THE SMALL VERTICAL MARKS AT TOP AND BOTTOM ARE FOR YOUR VERTICAL CUTS AND POSITIONING NOTE YOU SHOULD A VISUALLY LINE UP IMAGE SECTIONS.. C. HORIZONTAL WHITE MARKS RKS.OH THE END SECTIONS SHOW THE PLACEMENT FOR TOP AND BOTTOM PLACEMENTS D CENTER PANEL HAS A CENTER LINE TICKMARK E. SPECIAL ETO ALLOW FLEXIBILITY THE TICKS ARE PLACED OUTSIDE REFER TO FNISH PLAN FOR START POINT ���YYY,, HALL TULLTIDNS MAINTAIN FULL CHECKS ALONG THE CEILING TO LINE TRIM THE BOTTOM CHECKS IF REQUIRED DUE ACTUAL FIELD CONDITIONS ' DETAIL ITEM V BWC -04 -_ _ _ WALLCOVERING TO BE APPLIED VERTICALLY TO FILL NALL AREA - CEILING TO BASE AND SIDE • TO 510E (FINISHED FACE OF CABINET ENDS) . PRESENTATION DETAILS Bath Q LL.( T d � SOUTHCENTER MALL PH B •GRAPHIC MURAL WALLCOVERING - OF VISUAL UAL AREA.. INTERIOR TRIMS HAVE 3' EXCESS OVERLAP AND OF THE ISLE INTERIOR THE T 'PAINTED 4` "1/4" RED GINGHAM CHECK' WALLCOVERING 2 'I ' ° NOTE HEAL SIZE OP IMAGE APPLIED TO WALL WILL BET 6'H X 13' -6•11 . o SEATTLE, WASHINGTON m..1 OSOSeb W Works .c.1. E.L. M.Wn AS NOTED O} -1116 RDG 11.1 DETAIL T ' BWC -OZ . DETAIL , , BWC -01 TxREE LASTED PARKWAY COLUMBUS. OHIO 13230 614 -429-20OA