Loading...
HomeMy WebLinkAboutPermit B96-0145 - BOEING #21-05 - FENCING AND GATECity of Tukwila • `- (206) 4313670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: B96 -0145 Type: B -BUILD Category: ACOM Address: 3417 S 120 PL Location: Parcel #: 102304 -9068 Zoning: M1 M2 CM Type Const: II -N Gas /Elec: Wetlands: Water: 125 Contractor License No.: BOEINC*294ML Status: ISSUED Issued: 06/26/1996 Expires: 12/23/1996 Type of Occupancy: OFFICE Slopes: N Sewer: VAL VUE TENANT BOEING #21 -05 3417 S 120 PL, SEATTLE, WA 98124 OWNER SABEY CORPORATION 201 ELLIOTT AVE. WEST, SUITE 400, SEATTLE WA 98119 CONTRACTOR BOEING COMPANY P.O. BOX 3707, M/S IF -09, SEATTLE, WA 98124 CONTACT TERRY BENNETT Phone: 206 544 -2975 P.O. BOX 3707, M/S 46 -87, SEATTLE, WA 98124 k• k*** k** k***************** k***************k** *•k * * * * * * *** ** * * * ** * * * * * * ** ** ** Permit Description: REMOVE /RELOCATE FENCING. PROVIDE NEW FENCING AND GATE. SETBACKS Units: 001 Front: .0 Back: .0. Buildings: 001 Left: .0 Right: .0 Fire Protection: SPRINKLERED UBC Edition: 1994 Valuation: 6,000.00 Total Permit Fee: 189.71 * k************ k***** kkkk** kk**** k** kk*' k* kk* * *k * * * *k * * * * * * ** * * * * * * *** * * * * ** cocga Permit Center. Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this buil ' g pe m -- / — -- � � � Date: �P Signature:_ � Print Name: Title: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. ■••■•■., Jui6114,113., CITY OF TUKWILA Address: 3417 S 120 PL Permit No: 896-0145 Suite: Tenant: BOEING #21-05 Type: B-BUILD Parcel #: 102304-9063 **A*******A************ Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer andtheTukwilaBuilding Division. 7 '. All permits, inspection plans shall be available at the jobs.ite to the'startof any con- struction. Thesedocumentsare to be maintained and avail- able until fA00'ins7P0O'Jblv.approVal is granted'. 3. All construction to: aijkOroved plans and theUntform Building'Xodet1994 EditionaS'aMende,C- Uniform TheOhanital Lode (1994 Edition), -- ' ,2• and Washington State.gnergy,'COde,(1994 Edition) 4. Valid, of Permit. The,issuanOe,of a permit dr,approVaof plansspecificatTons, and computations shall not he con:.:, stru:Oz,tql0 a p,ermifjoror an of, any violation of #py o'e provis.iptis of'Aha:building code or,,of other ordlnanoe of the 1 uriS4iction:. No permit oi-esumitig to gimatit0o0i* to vt6late-Ocancei the provisionsofj.thisHH code shall be valAd':., --., - ..,. . . .-. • • • Status: ISSUED Applied: 05/22/1996 Issued: 06/26/1996 • !. ,.,: :: , "'S!*, "t. 44411., ATMEN7l DE R ,..,f: ;�r, ; t V. „ �bf';�. . off IPM � �r k, I �DAT;Es. INt k;tts': y .ay, ;D_AT E _� f ?;t , � : �.�3i A , -.• V E D , ,•'7. �: W .;o-. ,,.� Y n E x��.t� _ :,, ,, ,,.,:,. :i.: '' i t k S Yn � � � ) u .� �.t + ;o. �#� t -' 5 yi y � �y+S�S�✓�`+ t �'� , REQ . tJIREMENTS / COMMENTS; � 4 i r . y `,,, :t :.., :.. -.:.:: N.� ,. ,. : t :;•, ,,i,' : :1a „t t,Y.. fi.,, c . ;,F Plan Review Meeting -• �� /a 19(,) K 5t 0.612, =rrnstaloct on O Rdr 52.{x" ?.Erni e.Ft b "O1 _ INIT. _5 BUILDING - initial review 6 fri , 01 96 (ROUTED) CONSULTANT: Date Sent - Date Approved - BY: (init.) .P4 FIRE 6 1 k/ / (ch' il � IREPROTECTION: O Sprinklers 0 Detectors P§N/A IRE DEPT. LETTER DATED: (,.•%y.//64,. INSPECTOR: S / 3— tt INIT: - C - ( 0 4 Alfa i.■ 6., ZONING: PAR /LANDUSECONDITIONS? Oyes O No 1EFERENCEFILENOS.: INIT: VIINIMUMSETBACKS: N- S- E- W- O PUBLIC WORKS �� J.I S UTILITYPERMITSREQUIRED? OYes ONo f UBLICWORKSLETTERDATED: INIT: BUILDING - final review 4 `� / TYPEOFCONSTRUCTION: a CERT.OF000UPANCY? Oyes "~ UBC EDITION (year): I t j C (� -- INIT : IV BUILDING OFFICIAL / � f / G: ;;1 . INIT: 1( AMOUNT OWING: /� U1 CONTACTED LQ r � 1 1 1- q ( ec- -� DATE NOTIFIED - o� - (O B `, ( 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) PLAN CHECK NUMBER Ito 5 REVIEW COMPLETED CITY OF TUKWILA Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PROJECT NAME 110 n 5 k*Q1 SITE ADDRESS 34 1 � 5 la° PI SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. 02/15/96 SITE ADDRESS SUITE # 3 12- r44 Ft- -tai aoluel 21 VALUE OF CONSTRUCTION 2cco - # - 6 1 o GS Demolition (building) PROJECT NAME/TENANT &otzrNc,, .Det-eAusri_ 4 6P GT2et_P 1 ASSESSOR ACCOUNT 10 2,3(A (commercial) Li 0 Other TYPE OF Li New Building U Addition e Tenant Improvement WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) DESCRIBE WORK TO BE DONE: BUILDING USE ( ice, warehouse, etc.) t F , PI 2 (orr—ir Ja wii-riti164re,&) NATURE OF BUSINESS: AV, RALAILI f5 WILL THERE BE A CHANGE IN USE? St` No 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: 209, kiw Tenant Space: Area of Construction: &00 OR HAZARDOUS MATERIALS IN THE BUILDIN? S stem WILL THERE BE STORAGE OR USE OF FLAMMA LE, COMBUSTIBLE 0 No 0 Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: Sprinklers `Autom Fire Al arym PROPERTY OWNER . 6, pt 6 PAcr- 647-6 PHONE ADDRESS 'PO r3k 370 wlis L/ 57 �� te ( } PHONE ZItg1Z,.� "2247 CONTRACTOR 6h ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # 1;,0 �(MG _ 2.9 ti M EXP. DATE 1 _o (_ 9 ARCHITECT PHONE ADDRESS ZIP CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER O ILLS APPL ICA TION Il1US T HE FILLED OUT COMPLETELY I HEREBY CERTIF.Y;.THAT I; HAV BE : :AND`CORRECT AND BUILDING OWNER OR AUTHORIZED AGENT CONTACT PERSON SIGNATUR go PRINT NAM AADS DRES 15 r BUILDIN PERMIT APPLICATION DESCRIPTION BUILDING PERMIT FEE: PLAN CHECK FEE.:::: BUILDING SURCHARGE OTHER: TOTAL< - AMOUNT 11 d • �.� . t RCPT 0 • DATE :: READ AND ;EXAMINED THIS APPLICATION; AND KNOW' T HE SAME . M AUft HORIZED. > TO : APPLY FOR THIS: PERMIT sc).) 1^0� o. p4/5 No 87 L(Mk q63 1&00S -oo DATE PHONE CITY/ZIPgr , 1Z`{ - ZZO7 PHONE s� Y 2, APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely - follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES t0122/03 COMMERCIAL ;NEW COMMERCIAL BUILDINGS /ADDITIONS: n Completed building permit application (ono for each structure n Assessor Account Number Two sets (2) of the following: Specifications Structural calculations stamped by a Washington State licensed engineer I1 n Soils report stamped by a Washington State licensed engineer 0 Topographical survey C Energy calculations stamped by a Washington State licensed engineer or architect C Legal description fn Working drawings, stamped by a Washington State licensed architect, which include: . . • Site plan • Architectural drawings • Structural drawings • Mechanical drawings • Elevations • Civil drawings • Landscape plan n Completed utility permit application (one for entire project) Six (6) sets of civil drawings NOTE: See utility permit application and checklist for specific utility submittal requirements. RACK STORAGE n Completed building permit application n Assessor Account Number Two (2) sets of plans, which include El Building floor plan showing • Entire space where racks will be located • Exit doors • Dimensions of all aisles Tenant space floor plan showing rack storage layout, aisles and RESIDENTIAL NOTE: Include dimensions of racks (height, width and length), aisles and exit ways on plan. 1 1 Structural calculations stamped by a Washington State licensed engineer (rack storage 6' and over). SUBMITTAL CHECKLIST NEW SiNGLE•FAMILY DWELLINGS /ADDITIONS El Completed building permit application (one for each structure) ri Legal description n Assessor Account Number Ti Two sets (2) of working drawings, which include: • Site plan — - (On plan, show closest hydrant location. • Foundation plan Include access to building, showing • Floor plan width and length at access.) • Roof plan • Building elevations (all views) • Building cross - section : • Structural framing plans n Washington State Energy Code data n Completed utility permit application n Six (6) sets of site plans showing utilities NOTE: Building site plan and utility site plan may be combined. See utility permit application and checklist for specific submittal requirements Additional topographical and soils information may be required if unique site conditions. I I 1 :COMMERCIAL TENANT IMPROVEMENTS Completed building permit application (one for tenant) Assessor: Account Number: Two (2) setts Of construction plans; which include C Site plan Location of tenant space Existing and proposed parking r Landscape plan (if applicable, f e ;;change of use); C Overall building plan Tenant location:.: Use of adjacent (common Wail) tenant Overal dimensions of building or square footage Floor plan of proposed tenant space n Construction details C Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) NOTE: II any utility work Is to be done, submit separate utility permit application and pl ans REROOF n Completed building permit application (one for each structure) E - Assessor Account Number Narrative describing existing roof, material being removed, and material being installed NOTE :: A certification letter is required prior to final Inspection and sign - off of the permit ANTENNA/SATELLITE DISHES n Completed building permit application Assessor Account Number Two (2) sets of plans, which include: n Site Plan (showing building and location of antenna/satellite dish) In Details antenna/satellite dish and method of attachment Structural . calculations stamped by a Washington State licensed engineer may be required RESIDENTIAL REMODELS Completed building permit application (one for each structure ) n Assessor Account Number n Two (2) sets of working drawings, which include: • Site plan • Foundation plan • Floor plan • Roof plan •:Building elevations (all views • Building cross- section • Structural framing plans Nom: If any utility work Is to be done provide utility permit application and plans must be submitted • Tenant space plan with use of each room labelled.. • Exit doors egress patterns • New walls, existing wall, and walls to be demolished • Cross sections showing wall construction and method of attachment for floor and ceiling. REROOFS n Completed building permit application. (one for each structure) Assessor Account Number Narrative describing existing roof, material being removed, and material being installed NOTE: A certification letter Is required prior to final Inspection and sign off of the permit • TRANSMIT Number: 96004182 Amount: Permit No O96~0145 Type: O-OU[LD BUILDING PERMIT Parcel No: 102304~9068 Site Add,` 3417 S 120 PL Account Code Description 000/322^100 BUILDING - NONRES 000/345.83O PLAN CHECK - NONQES 000/386.904 STATE BUILDING SURCHARGE +**+*A*.A+++**++k++AA**»+**++++*+^++^++*a***+/:*+‘^+A.+*A++** `ITY OF TUKNILA NA y�< �~ �� ' ^ ��-��[ �J +*+*a****aic*+tc++itA+A+��A *+»• $r*+**+***++*A+**^+*++*++A+hic.k TRANSMIT 189.71 05/22/96 12:28 Payment Method: CASH Notatiun: BOEING Init: SL8 ------'--'---'-'-------------------'-'---''-----'---------~--- Total Fe*s: 189.71 This Payment 189.71 Total ALL Pmts: 189.71 Balance: .00 k+AA+kab**+Aa*a****A*+*^A**v*+kA**+*A*4***A+k****°+a+A+kA*/*+A Amount 112.25 72.96 4.50 �/ 8�� 56c3 Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature FINALAPP.FRM City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name BN e.\ - cp C ter A .) Address 360C1 5 17.1'34- �L Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued .I F . ' - = ' tkj; 335e MIIM..A.MA"TM i{'liiotc ?d I I Permit No. 3 - b 14- Thomas P. Keefe, Fire Chief 0 \.., Date T.F.D. Form F.P. 85 John W. Rants, Mayor s # � I I5 ‘\ - i Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 Project: a t . O J Ty pe of in to � �`1 Address: Date • ca Special instructions: Date wanted: a.m. p.m. Requester: Phone No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 F ^ ""' 11 " ! 7' 1 4 Approved per applicable codes. COMMENTS: L .J.. - Date: PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Inspector: Date: r $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: E'> P c II) . C 'OS Typ iecti n'sp Address: 1-i loo P1 Date callec�� / a /17 Special instructions: Date wante J 31,...7 .m. Requester: C„„ PhoneNo.: sgU�1Li.--)9 1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. , {�f Corrections required prior to approval. COMMENTS: Inspector: .INSPECTION RECORD Retain a copy with permit — (--qts A ? PTV M.. - (206) 431 -3670 ( 3) C1 I $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No.: Date: i Fire Department Review Control #B96 -0145 (512) Re: Boeing Company Building #21 -05 - 3417 South 120th Place Dear Sir: City of Tukwila Fire Department June 21, 1996 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Gates and barriers shall be openable without the use of a key or any special knowledge or effort. Gates and barriers in an exit shall not be locked, chained, bolted, barred, latched or otherwise rendered unopenable at times when the building or area served by the exit is occupied. (UFC 1208.2) Gates and barriers installed across an exit shall be of sufficient size as to be capable of opening so that the clear width of the opening is not less than the exit width required by the Building Code. (UFC 1208.3) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) • 2. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 Page number 2 Yours truly, cc: TFD file ncd City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief adopted Fire or Building Codes does not imply approval of such condition or violation. 6/L The Tukwila Fire Prevention Bureau Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A ISSUED BY DEPARTMENT OF LABOR AND INDUSTRIES RECEIVED CITY OF TUKWILA MAY 2 2 1996 PERMIT CENTER DRAWING INDEX DRAWING N0. SHEET N0. TITLE REVISION NO. DATE 21 -05 —A1 Al TITLE ORIG 05.20.96 21- 05 -1A01 1A01 EXITING PLAN B 05.20.96 21- 05 -1A17R 1A17R FLOOR PLAN — REMOVAL R 05.20.96 21- 05 -1A17 1A17 FLOOR PLAN A 05.20.96 21- 05 -1A18 1A18 PLAN A 05.20.96 r 99 KING COUNTS NRPORE OEFlCE G CENTER (FM) 99 FROM SEATTLE— TACOMA AIRPORT VICINITY MAP FROM DOWNTOWN SEATTLE EAST MARGINAL WAY CORPORATE PARR BY 599 TUKWILA 900 DEVELOPMENTAL CENTER DA FROM KENT & AUBURN EXIT 157 NT SCALE 00 BUILDING 21 -05 FLOOR SPACE /WELD SHOP (J #160084 -00) ENS f I & PACE G BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 AREA MAP BUILDING 21 -05 3417 SOUTH 120TH PLACE TUKWILA, WASHINGTON (EAST MARGINAL WAY CORPORATE PARK) 21 -02 EAST MARGINAL WAY CORPORATE PARK NO SCALE ASPOEOAW FACILITIES DEPARTMENT GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CRY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. VERIFY ALL DIMENSIONS PRIOR TO START OF CONSTRUCTION. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRED DESIGN REVISIONS. REVISIONS TO BE APPROVED BY CITY OF TUKWILA PRIOR TO PROCEEDING WITH PROPOSED REVISED WORK. CHECK BOX PROJECT CHECKLIST ® THESE DRAWINGS CONFORM TO THE 1994 U.B.C., U.F.C., U.P.C. AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA ZONING. ® COMPLETE BUILDING FLOOR PLAN SHOWING EXITING SYSTEM, DOORS, CORRIDORS AND PASSAGEWAYS. El ENGINEERING CALCULATIONS OF APPLICABLE). ® ROOMS LABELED PER OCCUPANCY PER U.B.C. (TABLE 10 —A). ® BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. ❑ NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: 1. GENERAL PERMIT (SHELL & CORE) 6 SETS OF ENERGY CALCULATIONS 2 SETS OF CIVIL DRAWINGS WITH UTILITIES 2 SETS SOILS REPORTS, STAMPED BY GEOTECHNICAL ENGINEER 2 SETS STRUCTURAL CALCULATIONS 2 SETS PROJECT CONSTRUCTION SPECIFICATIONS 2 SETS TOPOGRAPHICAL SURVEY 2 COPIES OF LEGAL DESCRIPTION 2 SETS OF WORKING DRAWINGS El 2. TENANT IMPROVEMENTS, 2 COMPLETE SETS ❑ 3. MECHANICAL, 2 COMPLETE SETS ❑ 4. FIRE PROTECTION /SPRINKLERS, 2 COMPLETE SETS ® BRIEF PROJECT NARRATIVE: REMOVE AND RELOCATE SHOP FENCING, CANTILEVER RACKS, EYE WASH, BOLLARDS, CURTAIN, PORTABLE BATTERY WATER CONTAINER AND SHELF. REMOVE UNISTRUT POSTS AND BASEPLATES. PROVIDE SHOP FENCING AND SLIDING GATE. PROVIDE LAGGING AT RELOCATED EQUIPMENT. ❑AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 ❑KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑RENTON, WA. 98055 • SEATTLE, WA. 98124 ACCEPTAB u f o x APPROVED BY DEPT DA 0. MILLER CHECKED 'H' /d 1, APPROVED NI APPROVED CITY OF TUKWILA APPROVED JUN 19 1996 AS NOTED BULGING DI DATE suonnr 06.20.96 G. MILLER 06.20.96 nn LAND USE CODE CODE REFERENCES CODE SUMMARY OCCUPANCY GROUP D AND F, DIVISION 2 (OFFICE AND WAREHOUSE) NO CHANGE IN OCCUPANCY FLOOR AREA (ACTUAL) 209,446 SF BUILDING FOOTPRINT STOR I FIRE PROTECTIONS FULLY AUTOMATI WET PIPE THROUGHOUT SEISMIC ZONE 3 FIRE ZONE 3 PARKING PRC✓IDED 739 PARKING RELUIRED 720 NOTE. MECHANICAL AND ELECTRICAL PERMITS ARE TO BE SUBMITTED SEPARATLY FROM THIS PACKAGE. IN TITLE SHEET BUILDING 21 -05 ARCHITECTURAL MASTER COL. M — RIP (CITY OF TUKWI LA) REVISIONS NO CHANGES SHALL BE MATER TO THE SCOPE OF WORK WITHOUT PRIOR APPROVAL OF TUKWILA BUILDING DIVISION. ROTE. REVIBIO S WILL REr.NIRE A NEW PLAN SUBMITTAL D.C. PILE COPY cnf.. - C . But; - o:MSion.. plur:.. . .,. RuNOr100 Ow VIolaL:a ..: LG code or 0rimeo& flow* Gf 000traclolo copy c` oppro •` plane D000 CC ' . A . -96 Pony* No 1:39(.0 _ 01 1994 U.B.C., U.F.C., U.P.C., AND THE WACSI -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. LAST SESSION i SYMBOL SHEET A DATE SLOB NB_ 147008 -00 DWG x0 21 -05 —A1 REGEIVEO CITY OF TUKWILA MAY 2 2 1996 HERMIT CENTER A ADD EXT. NO SMOKING SIGN B FLOOR SPACE /WELD SHOP (34160084 -00) MANUFACTURING ARFA 172,600 S.F. <100 OCCUPANTS 02. 7.96 05.20.96 FLOOR PLAN SCALE: 1 "= 30' -0" MECINNICAI EQQ1 IPMFNT ROOM 4,800 S.F. <16 OCCUPANTS lifAMEZAW FACILITIES DEPARTMENT 1.800 =LAB 7,800 S.F. <78 OCCUPANTS ACCEPT/8 LO s46616, 61.1=6 PPAIM BY EDDIE P. DUARIE a Eon EXITING PLAN LEGEND: BUILDING 21 -05 ARCHITECTURAL MASTER ALL EXIT PATH GENERAL NOTES: ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE, OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THIS WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. CONSTRUCTION NOTES: CITY OF TUKWILA APPROVED JUN 1 9 1996 AS NOTED BUILDING DIVT8I N am E gn, MAY 2 2 1996 PERMIT CENTER HIR 1A01 21 .05 -1431 F t7DI'l5 RACK TYPE FIRE PROTECTION HOSE STATION FLOOR 'PLAN SCALE: 1/8 "= 1' -0" ©• ©• REMOVAL LEGEND: WALL STEEL STUD PARTITION DEMOUNTABLE PAR fITIONS (7' -0" HIGH) METAL FACED PARTITION x x x x x SHOP FENCE PARTITION TYPE INDICATOR, REFER TO SHEET A200 GENERAL NOTES: 1. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE, OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THIS WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. REMOVAL NOTES: REMOVE EXISTING EYE WASH STATION COMPLETE. SAVE FOR REUSE. REMOVE EXISTING BOLLARD (TYPICAL OF 2). SAVE FOR REUSE. REMOVE EXISTING UNISTRUT POST AND BASEPLATE COMPLETE (TYPICAL OF 2). REMOVE EXISTING PORTABLE BATTERY WATER CONTAINER COMPLETE. SAVE FOR REUSE. REMOVE EXISTING SHOP FENCING COMPLETE (7 POSTS /BASEPLATES AND 6 PANELS). SAVE FOR REUSE. CUT EXISTING CONTAINMENT CURTAIN TO SIZE OF SLIDING GATE. SAVE FOR REUSE. (n, 1A OR 1A13R 1A16R Ai9R � I IA14R 1A$,OR 1AII5R 1A21R / REMSION BY GMM APPROVED FLOOR SPACE /WELD SHOP W160084 - 00) DATE 05.20.96 1w� foR REVISION BY APPROVED DATE ASIIZEZAfG FACILITIES DEPARTMENT ❑ AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 ■ SEATTLE, WA. 98124 ACCEPTA o w APPROVED BY D.R CH 0204.94 CHECKED CHECKED APPROVED APPROVED DATE SUBTRE FLOOR PLAN — REMOVAL ARCHITECTURAL MASTER BUILDING 21 -05 COL. C -E /5 -7 O.P. LAST REVSIOO I SYOROL LEFT 1 A 17 R JOB NO. DWG NO. 21- C5 -1A17R PATE KEY PLAN SCALE: NONE CITY OF TUKWILA APPROVED JUN 19 1996 AA NOTED BUILDING DIVIBL N 0 CITY OF MAY 2 2 1996 PERMIT CENTER SW A � I F 3f H 3F 3E 3n X-- E 39 )f' 3f RACK TYPE FIRE PROTECTION HOSE STATION O t85' APPROVED -0" s ®c ®�^ O L f! FACILITIES DEPARTMENT D AUBURN, WA. IT EVERETT, WA. ❑KENT, WA. ❑ PORTLAND, OR. ❑ RENTON, WA. • SEATTLE, WA. 98002 98201 98031 97220 98055 98124 D D a P rue u o sPEGIRCATD, :APPROVED DRAWN BY D.R. CH S ERFl 0 DATE 02.0 -0.94 r 0.P. _ 5 ±2'- FLOOR SPACE /WELD SHOP (J#160004 -00) OHM C 05.20.96 VA / .40 I I sT,EFT 1 A 1 7 "°"° ° E ±2'- C IN OPENING " v APPROVED BY P : PA A - R MI - N 13 FIRED 'Oa LA IV . -..,. - - SW A a APPROVED DATE s ®c ®�^ O L f! FACILITIES DEPARTMENT D AUBURN, WA. IT EVERETT, WA. ❑KENT, WA. ❑ PORTLAND, OR. ❑ RENTON, WA. • SEATTLE, WA. 98002 98201 98031 97220 98055 98124 D a P rue u o sPEGIRCATD, :APPROVED DRAWN BY D.R. CH S ERFl 0 DATE 02.0 -0.94 °DnP FLOOR PLAN n BUILDING 21-05 ARCHITECTURAL MASTER COL. C -E/5 -7 0.P. T REV9DR I S,�°D` DATE FLOOR SPACE /WELD SHOP (J#160004 -00) OHM .ai (A, 05.20.96 .EREO sT,EFT 1 A 1 7 "°"° ° E APPROVED BY D DATE CHECKED APPROVED "PPPO`E° Dws D, 21- 05 -1A17 145 FLOOR PLAN SCALE: 1/8'= ( 9 SEP ' TE PER IT AND APPRPVAL REQU ED CITY Of TUKWILA APPROVED JUN 1 9 1996 AS NOTED BUILDING DIVISIWN LEGEND: WALL STEEL STUD PARTITION DEMOUNTABLE PARTITIONS (7' -0" HIGH) METAL FACED PARTITION x x x x x SHOP FENCE 4 PARTITION TYPE INDICATOR, REFER TO SHEET A200 GENERAL NOTES: 1. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE, OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THIS WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. CONSTRUCTION NOTES: RELOCATE EXISTING EYE WASH STATION COMPLETE TO LOCATION SHOWN. MOUNT TOP OF STATION AT 4' -0" A.F.F. RELOCATE EXISTING BOLLARD COMPLETE TO LOCATION ADJACENT TO BATTERY PACK STAND (TYPICAL OF TWO). MOUNT TO MATCH EXISTING. (4 WA La "rA TON �vm am De, T RELOCATE EXISTING PORTABLE BATTERY WATER CONTAINER COMPLETE TO LOCATION SHOWN. MOUNT TOP OF SHELF AT 5' -1" A.F.F. INSTALL APPROXIMATELY 85 L.F. OF METAL SHOP FENCING (8' -0" HIGH), LAG EACH POST TO FLOOR WITH (2) 1/2" DIAMETER ANCHOR BOLTS (3" MINIMUM EMBEDMENT). LAG EACH CORNER/END POST WITH (4) 1/2" DIAMETER ANCHOR BOLTS (3' MINIMUM EMBEDMENT). PAINT ALL METAL SHOP FENCING (BDC1). L' RELOCATE EXISTING 7 POSTS /BASEPLATES AND 6 PANELS COMPLETE. INSTALL APPROXIMATELY 14 L.F. OF METAL SHOP FENCING (8' -0 HIGH). ALIGN NEW METAL SHOP FENCING WITH EXISTING METAL SHOP FENCING. LAG EACH POST TO FLOOR WITH (2) 1/2" DIAMETER ANCHOR BOLTS (3" MINIMUM EMBEDMENT). LAG EACH CORNER/END POST WITH (4) 1/2" DIAMETER ANCHOR BOLTS (3' MINIMUM EMBEDMENT). PAINT ALL METAL SHOP FENCING (BDC1). © INSTALL 24' -0" WIDE HI- PARTING SLIDING GATE WITH 14' -0" HIGH TRACK. INSTALL FOUR (4) PULL HANDLES AND HASP. LAG EACH POST WITH (4) 1/2" DIAMETER ANCHOR BOLTS (3" MINIMUM EMBEDMENT). PAINT ALL METAL SHOP FENCING (BDC1). RELOCATE AND CUT EXISTING CONTAINMENT CURTAIN TO SLIDING GATE. ATTACH TO GATE TO MATCH SLIDING GATE AT COL E /5. INSTALL 5' -0 "W x 16' -O H x 40' -0 "L CANTILEVER RACKS (ARMS AT 50 ", 98" AND 146" A.F.F.). INSTALL (2) 5/8" DIAMETER ANCHOR BOLTS PER BASE (2 3/4" MINIMUM EMBEDMENT). INSTALL LOAD LIMIT SIGNS: "MAXIMUM ARM LOAD 500LBS ". 1M O 1A13 1,416 1 1 A11 IA14 1 q A7 1AI8 KEY PLAN SCALE: NONE E ) 1A21 I _.�. H 000IVED ODD OF TOINJILA MAY 2 2 1990 79b-OH S REASON 4 160D84'FLODRSPACE /WELD SHOP BY JBURKS APPROVED H» DA o5 .20.9D REASON BY APPROVE° ANTE PLAN SCALE: 1/8" = RELOCATE CANTILEVER RACK TO COLUMN D/7 SEE DWG. 21- 05 -1A17 AWASOrAW FACILITIES DEPARTMENT 5) sv psKiE E0 141 VO ASBESTOS NO1044900: Agond lalth eowy of the wit arm hoe been conducted and asbestos containing materb' coo not Decoded Dot would be Iwdwd In the onetoolon of We pmfecl. Do not move, *mope er delu,b my otlwloe =NM odlownt to the co* won. Flom contact Boeing FooDS.0 Deportment If =balm aorta in matador b donagd or Tscowd that Y required to be moved la euppW cook the relieving mate de In the oreae dprent to Nh lob ma assumed to be posIllw for onkelo= LEGEND: GENERAL NOTES:: 1. G.C.U. CONSTRUCTION TEAM AND THE ENG. DESIGN !Tf,A MTSHALL REVIEW THE JOB TO CLARIFY THE WORK PRIOR TO STARTING THE WORK. 2. COORDINATE WORK WITH ALL TRADES REQUIRED TO: CQMPLETE -,. THE WORK. 3. LEAVE WORK AND STAGING AREAS CLEAN AND UNCLUTTERED END OF EACH DAY AND END OF JOB. 4. REMOVE ALL DEMOLISHED MATERIALS FROM BOEING PRQPERTY''Y 5. REMOVE ALL TOOLS AND REMNANTS OF MATERIALS FPQMr3RPTR)1 AREA. 6. NO CHANGES SHALL BE MADE TO THE DRAWINGS WITH QU I�t':. WRITTEN APPROVAL BY THE FACILITIES ENGINEER RESPONSIBLE. FOR THAT PORTION OF WORK. 7. POST ALL SIGNED AND STAMPED: DRAWINGS, SPECS, PERMITS,' AND INSPECTIONS RECORDS VISIBLE AND EASILY ACCESSIBL AT THE JOB SITE PRIOR TO COMMENCEMENT OF ANY: WORK,t 'u r ALL DOCUMENTS SHALL REMAIN UNTIL FINAL WRITTEN APPROVAL HAS BEEN RECEIVED AND THE OCCUPANCY RERMIT,i HAS BEEN ISSUED, AT WHICH TIME ALL DOCUMENTS SHALL, 1'.. BE DELIVERED TO TERRY BENNETT, BUILDING 9 -5:.2I COL. N/1 CONSTRUCTION NOTES: INSTALL 8' -O" HIGH SOLID SHOP FENCE. ALIGN FpNC POST WITH WEST CORNER OF FURRED COLUMN. INSTALL 13' -0" HIGH CURTAIN ABOVE SHOP PENQP, (SEE STRUCTURAL) 0 0 0 0 P a RELOCATE FOUR 5' X 16' HIGH SECTIONS OF� ";y CANTILEVER RACK. INSTALL LOAD LIMIT SIGNS MAXIMUM ARM LOAD 500 LBS." ARM SPACING qTE 50 ", 98 ", AND 146 ". INSTALL (2) 5/8" DIA A. BOLT WITH 2 3/4"111BE0, PER BASE. SEE DAJG 21 -05 - IA17 FOR NF INSTALL 16' -0" X B' -0" HIGH SOLID SHOP FF,N SLIDIING GATE , GATE TRACK ON HEADER BEAM 1; AT 14' -0" AFF INSTALL HASP STANLEY 911 INSTALL 13' -0" HIGH CURTAIN OVER NEW SH P HERCUUTE '10W MEDIUM DUTY, SHRINK RESIS LAMINATED FABRIC. MECHANICALLY FASTEN :PAN TOGETHER, .ADD JUTE WEBBING.TO TOP OF'PANK PLACE GROMMETS AT 1' -0" DC. TOP AND BOTT COLOR ROYAL BLUE EXISTING ELECTRICAL PANEL EXISTING PORTABLE EYE WASH TO REMAIN. INSTALL 4' -0" X 8' -O" SHOP FENCE DOOR Wr ..�'. , LOCKSET YALE LF5407AU 26D INSTALL 3 X 3' X 7' METAL SHELVING INSTALL ONE 14' -0" X 16' -0" HIGH PALLET ,K ,., SPACE SHELVING AT 4' -0" INTERVALS. INSTALL' EQ LIMIT SIGNS " MAXIMUM SHELF LOAD 5000 LBg UNIFORMLY DISTRUBUTED." INSTALL. (2) 1/2" DIA. A. BOLTS PER BASE o o 0 me MEN, GIs D o ROCEIVED cm oR ruI<wlu MAY 2 2 1996 PEDANT CENTER Itl:Y PLAN ACCLr µu> SPEnESUnDx TA IS APPROVED APPROVED BY DEPT. KRIS ANDERSON O IECNED KRIS ANDERSON APPROVED DATE APPROVED 12 -14-94 12 -14-94 PLAN BLDG. 21 -05.1 ARCHITECTURAL MASTER COL. E —G/5 -7 CORP. PARK LAST RENA4I 1 911190/ ME 1A18 FOATE J00 NO. 727230 — OM NO, 21 -05 -1A 8'