Loading...
HomeMy WebLinkAboutPermit B96-0165 - SEGALE RETAIL - SUITE 700 - RESTROOM AND STOREFRONTCity of Tukwila (- (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No B96 -0165 Type: B -BUILD Category: ACOM Address: 300 ANDOVER PK W Location: Parcel #: 262304 -9119 Zoning: C2 Type Const: II -N Gas /Elec: Wetlands: Water: N/A Contractor License No.: LAPIALP055MZ Status: ISSUED Issued: 08/27/1996 Expires: 02/23/1997 Type of Occupancy: STORE Slopes: N Sewer: N/A TENANT SEGALE RETAIL SUITE 700 300 ANDOVER PK W, TUKWILA, WA 98188 OWNER SEGALE M A INC PO BOX 88050, TUKWILA WA 98188 CONTRACTOR LA PIANTA LIMITED PARTNERSHIP P.O. BOX 88050, TUKWILA, WA 98138 CONTACT DANA WARREN P.O. BOX 88050, TUKWILA, WA 98138 Phone: 206 575 -2000 Phone: 206 575 -2000 k .k k k k k k k k*k *k*k *'k* kit k* *•k•k k k********•k**k*** k•k **k *****k****** ** ********** **** Permit Description: ADD DEMISING WALL, RESTROOM, AND STOREFRONT. Units: 001 Buildings: 001 Fire Protection: SPRINKLERED U3C Edition: 1994 SETBACKS Front: .0 Back: .0 Left: .0 Right: .0 Valuation: 29,000.00 Total Permit Fee: 640.99 k.kkkk, A **kk*** *kkkk*** ** k**kk*********** * * * * * ** ******* * * * * *kk. **** ** *** ** CQ Permit Center. Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to'be true and correct. All provisions of law and ordinances governing • this•work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. .I am authorized to sign for and obtain this building permit. 0_ dZO.LV Date: We72..41 fit? )i—J4Va/ This permit shall become null and void if the work is not commenced within 130 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA. Address.: 300 ANDOVER PK W Permit No B96- 111E+5> Suite: Tenant: SEGALE RETAIL SUITE 700 Status: ISSUED Type: B -BUILD Applied: 06/12/1996 Parcel #: 262304 -9119 Issued: 08/27/1996 ' kk k: 4kkkkk 'k:4;t'k'k**kk•k•kk'kkk•k:kk kk4k 4k k'k k'k*k k:k•k 4kkk•kk k•kkkk;k•k44 kk k 4ak t 4 kk:k Permit Condition: 1. PRIOR TO FINAL SIGN OFF APPLICANT 'SHALL SUBMIT METRO SEWER USE CERTIFICATION FORM TO PW FOR PROCESSING. 2. No changes w i l l be made to the plans un 1 ess, approved by the Architect or Engineer° and the Tukwila Building Division. 3. Plumbing permit_ shall be obtained through the Seattle-King County Department of Public. Health. Plumbing will be inspected by that agency, including all gas piping (296 -4722) . 4, Electrical per•mi is sha 1 1 be obtained through the Washington State Division of Labor and Industries. and all electrical work w i l l be inspected by that agency (248-6630). 5. All mechanical work shall be under separate permit issued by the City of Tukwila. • 6, All permits, inspection records., and approved plans shall be available at the job site prior to the start of any con- struction.: These document_ are to be maintained and avail- able: until final inspection approval is granted. All structural welding shall be done by W.A.B.O, certified welders and special inspected (UBC - Sec.. 306(a)5). 8. Bolts installed in concrete shall be special inspected (UBC - Sec. 306(a)2) 9. When special inspection is required_ either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the. inspection agencies. prior to the f it St bui ldirig inspection.' Copies of all special inspection reports shall be submitted to the Building DiviSion in a timely manner. Reports shall contain address, project name, permit number and type of inspection being performed. 10. The special inspector shall submit a final signed rt port stating whether the wart: requiring special inspection was., to the best of the inspector's knowledge, in conformance with approved plans and s p e c i f i c a t i o n s and the a p p l i c a b l e workmanship provisions of the UBC. 11. All construction to.be done in conformance with approved plans and requirements. of the Uniform B u i l d i n g Code ( 1994 Edition) as amended, Uniform Mechanical Code (1994 Edition). and Washington ':Mate Energy Code (1994 Edition). 12. Validity of Permit. The issuance of a permit or approval of plans, specifications., and computation shall not be con- strued to be a permit for, or an approval of, any violation of any of the p r o v i s i o n s of the b u i l d i n g code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. Srt esvea,t** t •� �< DERyARtME' �':��t11' l',Iti I r��'if fi l '; i yl ' �. �:,� DATE >= , 4G , � A s A', ,; � t'f . {j.. K . . � �.�DAT:E��� �x ��'{`�' .� < t;t , y it; APPROVED 3 {t' ?� kfa/ ♦'. Aii,,,C' y r .. • 5 : , , ,� t F � w' +'�� ��. Y#:,?Yfx � ,�:;;•;,1,., sy ar:a , s� °s ; x ;��# , �,E F, � , ;r �. - � �, , T t -; , ' 5 rR E QU I RE M ENTS '/ tC { O �MME NT ,S ° : N „� ' + . y .,1�. .. �u:k4 ^c <:�., .9:s 5..:^{.. r 'f� »� :` :r :. l� Y.. .T,_. k Plan Review Meeting DATE NOTIFIED (0 t dl (o ,. Q(0 ( ta, 9 0 INI j'j XBUILDING - , initial review 6/206 & G.7 C • ��IG (ROUTED) OONSULTANT: Date Sent - Date Approved - FIRE " 0.9* c/2�/4j c. lIREPROTECTION: Sprinklers ❑ Detectors O WA -IRE DEPT.LETTER DATED: 2,y /cif, INSPECTOR: S" / r INIT: 414»1 t...F Zki L "ZONING: PAR /LANDUSECONDITIONS? °Yes f No FILE nEFERENCEFIL C INIT: Id L) MINIMUMSEfBACKS: N- S- E- W- + PUBLIC WORKS 7 f (qic 7j006 JTILITYPERMITSREQUIRED? QYes 4 N rUBLICWORKSLETTERDATED: INIT: ,1(�" �J 0 BUILDING - final review 7-6 -9 7-Z6- 9(o TYPEOFCONSTRUCTION: II, N CERT.OFOCCUPANCY? GYes No UBC EDITION (year): 199+ INIT: ,�) (X BUILDING OFFICIAL 7-25.-q(0 7 X, /cd • INIT: AMOUNT OWING: 6 CONTACTED �� DATE NOTIFIED 1 ,. Q(0 BY: (init.) 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) PLAN CHECK NUMBER 610146 CITY OF TUKWILA Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N/A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. REVIEW COMPLETED PROJECT NAME SUITE NO. SITE ADDRESS 50D c \ov .P Y PK W 02/15/96 v,)w wUItIUWnrer DUUI&Vd(U, I U1wna vl/ft yo r oa (206) 431-3670 '.. DESCRIPTION AMOUNT - 15 RCPT # DATE BUILDING PERMIT FEE PLAN CHECK NUMBER OP ' o' / APPLICATION MUST RE FILLED OUT COMPLETELY PLAN CHECK FEE: u BUILDING SURCHARGE OTHER: TOTAL - (pi0A SITE ADDRESS SUITE # 300 Andover Park West, 41600/700 VALUE OF CONSTRUCTION - $ $29,000 PROJECT NAME/TENANT Segale Retail, Suite 700 ASSESSOR ACCOUNT # 262304 - 9001 TYPE OF 0 New Building U Addition 13 Tenant Improvement (commercial) U Demolition (building) WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) 0 Other DESCRIBE WORK TO BE DONE: Add demising wall, restroom and storefront BUILDING USE (office, warehouse, etc.) Retail NATURE OF BUSINESS: Retail WILL THERE BE A CHANGE IN USE? ® No 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: 123,051 Tenant Space: 4871 SF Area of Construction: 4 , 871 SF WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 1 No 0 Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: Sprinklers n Automatic Fire Alarm System PROPERTY OWNER La Pianta Limited Partnership PHONE 575 -2000 ADDRESS P.O. Box 88050, Tukwila, WA ZIP 98138 CONTRACTOR La Pianta Limited Partnership PHONE 575 -2000 ADDRESS P.O. Box 88050, Tukwila, WA ZIP 98138 WA. ST. CONTRACTOR'S LICENSE # LAPIALPOSSM@ EXP. DATE 7/9/96 ARCHITECT Lance Mueller Architects PHONE 325 -2553 ADDRESS 130 Lakeside, 41250, Seattle, WA ZIP 98122 CITY OF TUKWILA Department of Community Development - Building Division BUILDINI PERMIT APPLICATION I' HEREBY ;CERTIFY THAT I HAVE READ: ANDiEXAMINED THIS APPLICATION :'AND KNOW THE SAME BE -TRUE AND CORRECT, AND I AM:AUTHORIZ TO APPLY FOR THIS:PERMIT BUILDING OWNER SIGNATURE 0 G�' OR 1 / DATE 6/10/96 AUTHORIZED AGENT PRINT NAME Dana Warren ADDRESS P.O. Box 88050 CONTACT PERSON Dana Warren PHONE 575 -2000 CITY/ZIP Tukwila 98138 PHONE 575 - 2000 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES 1Q - 10/22/09 • COMMERCIAL NEW COMMERCIAL BUILDINGS /ADDITIONS [n Completed building permit application (one for each structure ❑ :Assessor Account Number Two sets (2) of the following: Specifications Structural calculations stamped by a Washington State licensed engineer [ Soils report stamped by a Washington StateliCensed engineer ri Completed utility permit application (one for endre project) n Six (6) sets of civil drawings (VOTE: See utility permit application and checklist for specific utility submittal requirements. Topographical survey n Energy calculations stamped by a Washington State licensed engineer or architect [ Legal description Working stamped by Washington State licensed :. architect, which include: • Site plan • Architectural drawings • Structural drawings • Mechanical drawings • Elevations • Civil drawings • Landscape plan RACK STORAGE [. Completed building permit application I Assessor Account Number Two (2) sets of plans, which include: Building floor . plan showing • Entire space where racks will be located • Exit doors :. • Dimensions of all aisles Tenant space floor plan showing rack storage layout, aisles and .;. exits. NOTE:: dimensions of racks (hei : : ght, width and length); aisles and exit ways on plan: n Structural calculations stamped by a Washington State licensed engineer (rack storage 8' and over) RESIDENTIAL SUBMITTAL CHECKLIST NEW SINGLE- FAMILY DWELLiNGSIADDITiONS n Completed building permit application (one for each structure) [ Legal description n Assessor Account Number n Two sets (2) of working drawings, which. include: • Site plan -OP- . (on plan, show closest hydrant location • Foundation plan include access to bupoing, showing • • Floor plan width and length or access.) • Roof plan • Building elevations (all views) • Building cross - section • Structural framing plans n Washington State Energy Code data n Completed utility permit application Six (6) sets of site plans showing utilities NOTE: Building site plan and utility site plan may be combined. See , utility permit application and checklist for specific submittal requirements. Additional topographical and soils information may required if unique site conditions. COMMERCIAL TENANT IMPROVEMENTS Completed buliding,permlt application (one: for each•structure or tenant) Assessor Account Number Two (2) ;sets of construction plans. which include Site plan Location of tenant space Existing'and proposed parking Landscape plan (if applicable, i e„ change of use Overall building plan Tenant location Use of adjacent (common Wall) tenant • Overail.dfntension$ of building or square foots Floor plan of proposed tenant space • Tenant space plan with use of each room labelled.. • Exit doors egress patterns; • New walls, existing wall, and walls to be demoiis Construction details • Cross sections showing wall construction and method of attachment for floor and ceiling [ Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) NOTE: If any utility work Is to be done, submit separate utility permit application and plans. REROOF [ Completed building permit application (one for each structure) Assessor Account Number n Narrative describing existing roof, material being removed, and material being installed NOTE: A certification letter is required prior to final Inspection and sign off of the permit . . ANTENNA/SATELLITE .DISHES Completed building permit appiication n Assessor Account Number Two (2) sets of plans, which include: • Roof plan • Building elevations (all views • Building cross-section • framing plans Site Plan (showing, building and location of antenna/satellite.dish) n Details antenna/satellite dish and method of attachment Structural calculations stamped by a Washington State licensed engineer may be required RESIDENTIAL REMODELS ri Completed buildng permit application (one for each structure n Assessor Account Number n Two (2) sets of working drawings, which include • Site plan Foundation plan; •: Floor plan NOTE; If any utility work is'to be done provide utility permit application and plans must be submitted. REROOFS; n Completed building permit application (one for each structure) n Assessor Account Number Narrative descnbing existing roof, material being removed, and material being installed; NOTE A certification letter is required prior to final !nspection:and sign .• 't 0 I' •• ****.4Vh**.it***************A *A4****Ak*******A***4k 3k *.ArA**** CITY OFT UVWILA. WA — rEANSMIT TRANSMIT Number: 96004249 Amount: 640.99 06/12/96 11:02 • Payment Method: CHECK Notation: SEGALE BUSINESS 'nit: SLR Permit No: 096-0165 Type: 0-DUILD BUILDING PERMIT Parcel No: 262004-9119 Site Addriesst 300 ANDOVER PK W This Payment 640.99 .ki****Ah** Account Code 000/322.100 000/345.830 000/386.904 Total 640.99 iota( ALL Pmts: 640.99 Balance: .00 Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING 5.0JRCHA1GE Amount 3c35.25 250.74 4.50 0448 06/12 9616 TOTAL 640.99 Project Name Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: 5 I C� Authorized signature City of 7111mila Fire Department TUKWILA FIRS DSPARTMSNT FINAL APPROVAL FORK C) Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued FINALAPP.FRM T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Are Chief Permit No. S 'J (,75 Address •��� � � C�,,- .\)\‘. Suite # ✓ ?C`() ! 5 \Qq Date Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Plan (206) 5754404 • Fax (206) 57544139 Proiec Type of ins i_ _�_�__I_� Adcye s0 ' �`., l Special instructions: ()cir6 ._ C61 ( t - ��w * .� cv Date called: .. Date wanted/ — ��,9 a.m. `'� p.m. Req U �l -(scsin Phone No61 a-C Q INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 ri>[ Approved per applicable codes. COMMENTS: Inspector: INSRECTION RECORD Retail a copy with permit Date: ` 431-- . 1 3.0 q7 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to Inspect) n, fee must be paid at 6300 Southcenter Blvd., Suite 100: Call to schedule reinspection. Receipt No.: Date: COMMENTS: C-0 i`l STIL (A GC- _Dc si /46 vim- L-- b,- 1k1-9 L,,, (714 G u.6\,Q2J 6 icg" s f o den..( e 11-03 9 -Ft-T1 Ay" 71 fi-Krr A P C...14-i 0 tA chc T/d- / 4- G (L.- t4 i±i c fi'l AK CArvvi pc, ( 6F TH-, s T L . LA /./Niv.-c:vssAiN ili-i .-S i' /7 tAm.c... f- GA-NJ cE A i--0 (4 ' (-z - w or- J) LL i4 65 i1/4 --9 F a i t,..._ A . 9, f-r--,, Tk- 1 - "1 r-;.A Tit (LC Project: • .r Type of inspectioh: )7 _ / Address /1/76a Date called: Date wanted: R. Special instructions: 5..), f 700 it1e.ef c f 7 e :3 C., A/Pe d .,.. r . . , , , sitze Requester: sk.t Nor‘a--) Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 I I Approved per applicable codes. Inspector: INSPECTION RECORD? Retain a copy with permit I I PERMIT NO. (206) 431-3670 Corrections required prior to approval. Date: 1 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 4regk 2.crAlL. g ... z o Ty of tk I t 1 Nei m EsA tattisiz_ p ‘.\. Date called: 9 _, Special instructions: Date wanted: 9 Requester: s1E.4 E. Phone No.: 0(1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 tiale.,11:901.nomem Approved per applicable codes. INSPECTION RECORD Retain a copy with permit 241.&;..At: Mir* trt!tt 516- 0 IG5 PERMIT NO. (206) 431-3670 COMMENTS: , AEA r d r 4 7 L, 146 Inspector: Date: 7q(1 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, Receipt No.: Date: COMMENTS: T ype of inspection: FOA A f ` , 1 9 ( N � f f _.0 — )11 /51/N\ 6 - (A/ A'LC,. -- 01N3 Lla-JZ "i"- 7. Requester: Requester: >J e ckt. - 6 ( 1 ,.l ST !8 L, s'ro'ect wt.... _ STI: T ype of inspection: FOA A f ` , 1 9 ( N � ddress: A _ • ` rtit • l J�N.w t W Date called: 9 _ `0 _ 1 t0 Special instructions: ENE. 7149.v. s (Tr. tc Oc) • Date wanted , ` �l0 �a.ni , p.m. Requester: Requester: p \ S ab1000 10+_51 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector: INSPECTION NO. proved per applicable codes. [ReceiPt No.: INSPECTION RECORD Retain a copy with permit Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter BIv ; .Suite 100. Call to schedule reinspection. • assxraeh26imL �%.T E M L!bWAV (:MVM. i 7..`..�. PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: COPIES DATE NO. DESCRIPTION r&F,4 /. c Q>€-7 t, t, , .(-1 T5S . ro re_ Al fxv 0 r,.ItAJC7 1 C1LCA . ENGINEERS NORTHWEL , INC. 6889 WOODLAWN AVENUE N.E. • SUITE 205 SEATTLE, WA 98115 (206) 525 -7560 FAX # (206) 522-6698 TO l,M Q WE ARE SENDING YOU Q' Attached D Under separate cover via ❑ Shop drawings ❑ Prints ❑ Plans COPY TO 11 .nclo.uro..r, not as noted, kindly' notify us at on". E' SF `TRU BITMIL DATE -4-% I JD. ND. o g 4.ot ATTENTION V 'J RE st( o F,R P �taLL the following items: ❑ Samples 0 Specifications ❑ Copy of letter ❑ Change order ❑ THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ Approved as submitted ❑ Resubmit copies for approval 1 k.4or your use ❑ Approved as noted ❑ Submit, copies for distribution As requested ❑ Returned for corrections 0 Return corrected prints ❑ For review and comment ❑ ❑ FOR BICIS DUE 19 ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS SIGNED: RECEIVES JUN 41996 LANCE MI ft l FK w RECEIVED CITY OF I UKWILA StrWrritS36 PERMIT CENTER V1 ..4 it INA. C.401-g4z- 1 ov -A sif ? 4 - - 4 fr A • 6 :\ ,,,, CI DWN: , . ENG'D: . 1 aNNtwq • II 1: ' 1.. - i — 4 , - , tsTE.vt 'sto stkc" NAL JOB NO: DATE: ENGINEERS NORTHWEST, INC. .6869 WOODLAWN AVE. N.E. SEATTLE, WASHINGTON 98115 SHEET 1 DCPIRES 11/12/ ci4 1 0 PM SKS Ts. st42.00603t.cm t4. stDC. eft,0 tie 0 rot.. i kt, 0 14 1 & 1 0,7%; PNL. te, Vieo tIJp . 1t 6 - s t53. f. TA K*) t Left / ‘pA . C fa- . ‘I' ,ov .e AY . - 3 .. r r • 0 - t , , IF " 4 ,, 1 0039 4 - Gts-reil- IVALS . OWN: ENV!): 0,0 Nt4 oruJogi - -, JOB NO: DATE: ENGINEERS NORTHWEST. INC. . 6869 WOODLAWN AVE. N.E. SEATTLE, WASHINGTON 98115 . SHEET 2. or 2- [EXPIRES 11/12/96 1 Yf. caf fLAO . - leF/ W2-$4 K45-1- (44v,ow B0 L 6E.0 2 1 - 3/4 4 I • 13/.6. qt-gAt lucti emm sm,rs cemteo 41,41-N STRUCTURAL CALCULATIONS FOR STRANDER RETAIL T.I. Tukwila, Washington June 6, 1996 I [WIRES 11/12/ ett. 6869 WOODLAWN AVE. N.E. - SUITE 205 '- SEATTLE, WA 98115 - (206) 525 -7560 - FAX # (206) 522 -6698 Joe NO Joe NAME TP.A). rt l -' " � - A(I. DATE (o 41(n SUBJECT SHEET OF BY ENGINEERS- NORTHWEST INC. P.S. fi ('t • tlit t 417 1)l. L-1, /u,oI .'►l. ae(1. Cly 4 v4 LDE (ov-r. i(-. • t,tticQt.* '�rc S$'` = 4.b o• • t o r_,r, rTc.. 4( °.?) ENGINEERS - NORTHWEST CONCRETE JAMB DESIGN (version 3.0) Sheet of 6869 Woodlawn Ave NE 1988 UBC Strander Retail Seattle,Washington 98115 08:37:00 06 -04 -1996 Nev Opening - =------------------------------------ --- -po 100= ---------- - JAMB DATA height (ft) width (in) • thickness (in) add thickness (in) K factor parapet ht (ft) 30.00 40.00 7.25 0.00 1.00 0.00 SPANDREL DATA thickness(in) offset (in. + outward) 7.25 0.00 OPENINGS LEFT width (ft) height (ft) RIGHT width (ft) height (ft) 18.2 9.0 0.0 0.0 MATERIAL DATA concrete (psi) rebar (psi) 3000 60000 LOADING DATA untutored wind in (psf)= 24.2 out (psf)= 24.2 seismic... zone 3 press (psf)= 62.1 import fact= 1.00 ledger LL(plf)= 600 DL (plf)= 384 ecc (in)= 0.0 1 LL w /seisIic= 0 concentrated load LL(lbs)= 0 DL (lbs)= 0 ecc (in)= 0.0 1 LL w /seisuic= 0 concentric load LL(plf)= 0 DL (plf)= 0 1 LL v /seis.ic= 0 horiz load plf (+ invard)= 0 dist above floor(ft)= 0.0 REBAR DATA Vertical 4 t4 d= 3.63 Horizontal min in ^2 / ft 0.17 MOMENT AND DEFLECTION RESULTS + inward - outward Case Pu (kips) Mu (in-k) Phi*Mn (in -k) defl (in) Allow defl(in) Comments 1 5.9 954.5 57.14 146.28 2.40 NO GOOD, no convergence 2 5.9 -994.7 57.14 1- 155.30 2.40 NO 6000, no convergence 3 5.9 - 717.7 57.14 -95.08 2.40 NO 6000, no convergence 4 8.3 3520.3 61.80 198.80' 2.40 NO 600D, no convergence 5 8.3 1- 3847.1 61.80 1- 221.61 2.40 NO 6000, no convergence 6 6.8 1- 1221.4 59.08 -82.08 2.40 NO 600D, no convergence 7 12.9 -16.2 66.18 -0.11 2.40 case ok used interaction curve --, LOAD CASES 1) .9DL + 1.301. inward 2)' .901 + 1.3WL outward 3) .9DL + 1.43E0 4) 1.0501 + 1.2811 + 1.2801 inward 5) 1.05DL + 1.2811 + 1.28WL outward 6) 1.0501 + 1.2811 + 1.4E0 7) 1.401 + 1.711 INTERACTION CURVE DATA .7*Po .7 *Pbal .7t$bal .72Mn 124.2 29.0 106.1 34.2 NOTE in cases 1), 2), 4), and 5) the LL used is 1/2 of the applied LL (1 PM LTh ADD sTro►stiBJ tiv sui g-r JAt- g LAT At- 4 ENGINEERS NN Cosii4ential vl r W2 u = 297.66 C = 5395.09 T = 3906.79 IWVT TS MOMENT OF INERTI v3'1 u4 DEFL. = 2.06 ALLOWAILE DEFLECT 2.40 V = 4465 M = 31254 6/4/96 H ft = 30 hft =10 vl ft = 3.3 v2 ft = 18 v3 ft = 3.3 v4 ft = 0.0 v5 ft =0 1 v5 lateral design 24.2 H /150 = 2.40 SRINA3 = 9.29 IRINA4 = 29.18 90.904- of 8 v 6 A6 MEXIST = 33487 77.94 MISOLATE= 29766 PANEL WITH STRONG BACK IS OK P c= 3000 vind = 24.20 psi seismic 20.39 psf y1= 1 r= 8 y2= 1 SUM = 10 C80 4627 MAX T = 5395.1 TABS BASE VERT 5' CLEAR PLATE 11/0 INSPEC BOLTS pl dia.TO EDGE INSPEC BOLTS DIA. F'CKSI EMBED T allow REQ'D PL thick V al REQ'D 1/2 3 2 1/4 615 8.77 9 0.274 1840 3.00 1/2 3 3 1/2 1000 5.40 9 0.274 1840 3.00 1/2 .3 6 1080 5.00 9 0.274 1840 3.00 5/8 3 2 3/4 875 6.17 11 0.248 2875 2.00 5/8 3 4 1335 4.04 11 0.248 3125 2.00 5/8 3 7 1625 3.32 11 0.248 3125 2.00 3/4 3 3 1/4 1090 4.95 12 0.237 3875 2.00 3/4 3 4 3/4 1940 2.78 12 0.237 4225 2.00 3/4 3 8 2315 2.33 12 0.237 4225 2.00 Page 1 CITY OF TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL PLAN CHECK/PERMIT NUMBER: B I - 0 to PROJECT NAME: D ,Q 1 E, 1 PROJECT ADDRESS: RnCiNer VV - 700 DATE: CONTACT PERSON: SUBMITTED TO:_ Bldg. sA€/ve, ieksoc) PHONE: 5` i3 REVISION SUMMARY: ? \ d d(CLwi no A. IAJLA- -c.3 _ LOB SHEET NUMBER(S) • _ c i' "Cloud" or highlight all areas of revisions and date revisions. 7 Planning Fire k tc WO;St 6 Or) RECENED CITY OF TUKWILA SEP 2? 1997 CITY USE ONLY Public. Works 046-6te,a, '/L00%, 3/19/96 6 eg PROJECT NAME: PROJECT ADDRESS: CONTACT PERSON: Bldg: CITY OF TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL DATE: 7 2 1 "` lam' PLAN CHECK/PERMIT NUMBER: 8f -o/65' --r/ -/7 - PHONE: 5722C Planning Fire RECEIVED CITY OF TUKWILA JUL 2 4 1996 PERMIT CENTER REVISION SUMMARY: .r p:rgfrk6 ,& 16Re z6 SHEET NUMBER(S) % L� "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED TO: Public ..Works 3/19/96 Robert Benedicto Sr Plans Examiner City of Tukwila 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 Re: Segale Retail, Suite 700 #B96 -0165 Dear Mr. Benedicto, Dana Warren Enclosure SEGALE BUSINESS PARK Item #1 The small room in the rear of the space has been removed. RECEIVED CITY OF TUKWILA JUL 2 4 1996 PERMIT CENTER Enclosed is a revised sheet #A2 with corrections per your June 25, 1996 letter. The following corrections have been made: Item #2 A note has been added that exit illumination will be provided per UBC 1012.2. Item #3 A note has been added that mechanically operated ventilation system per UBC Chapter 12 will be provided. Please feel free to call me if you have any questions. Very truly yours, SEGALE BUSINESS PARK P.O. BOX 88050 • TUKWILA, WASHINGTON 98138 • TELEPHONE 206 575 -2000 • FAX 206 575 -1837 July 9, 1996 Mr. Dana Warren PO Box 88050 Tukwila, WA 98138 Subject: METRO Sewer Use Form /Business Declaration Segale Retail, Suite 700 300 Andover Park West, #600/700 Plan Check No.: B96 -0165 Dear Mr. Warren: A METRO Non - Residential Sewer Use and Business Declaration form is enclosed. You will also find instrctions on how to properly complete the form. Please complete the forms and return them to me for further processing. The completion of these forms are necessary due to the addition of new plumbing fixtures for your project. If you have any questions regarding these forms, please call me at (206)433 -0179. Sincerely, d Michael Villanueva Permit Technician II MEV /mev Enc. a/s cf: Permits Development File Building File City of Tukwila John W. Rants, Mayor Department of Public Works Ross A. Eamst, P. E., Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: (206) 433-0179 • Fax (206) 431-3665 City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Fire Department Review Control #B96 -0165 (511) June 27, 1996 Re: Segale Retail Center Building - 300 Andover Park West, Suite #700 Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "A11 Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Maintain fire extinguisher coverage throughout. 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 -4404 • Fax (206) 575-4439 Page number 2 City of Tukwila Fire Department doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. 3. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) When two or more exits from a story are required and when two or more exits from a room or an area are required by U.B.C. Section 3303, exit signs shall be illuminated. (UBC 1013.3) 4. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13- 4- 4.1.3.2.1) 5. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All sprinkler system plans, calculations and the John W. Rants, Mayor Thomas P. Keefe, Fin? Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575.4439 City of Tukwila Page number 3 Fire Department Thomas P. Keefe, Fire Chief contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 6. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 7. When walls and ceilings are required to be of fire resistive or noncombustible construction, interior finish materials shall meet the requirements of Uniform Building Code 803. The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of The Uniform Building Code. (UBC 804.1) 8. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57$4404 • Fax (206) 575.4439 Page number 4 Yours truly, cc: TFD file ncd Ato City of Tukwila The Tukwila Fire Prevention Bureau John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575.4439 June 25, 1996 Dear Mr. Warren: City of Tukwila Mr. Dana Warren P.O. Box 88050 Tukwila, WA 98138 4.4% .•..,, c,r c.- Swnnfa.wezumg h ,,,... wfN. iY,,,,,,: tb1 Department of Community Development Steve Lancaster, Director Re: Segale Retail, Suite 700, tenant improvement # B96 -0165 The initial plan review by Tukwila Building Division has been completed and your application has now beeri routed to Fire Prevention, Planning, and Public Works. Upon approval by the listed departments, your application will be returned to Building Division for final review coordination and the preparation of the permit documents. Prior to concluding review and approval by Building Division clarifications to the space plan will be necessary. The following comments are applicable: 1. The new suite has been divided into two area which are not labeled as to the intended use of each. If the smaller of the two area is to be used as a storage room, a means of separation must be provided between the storage room use and the required second egress path. If this space is not intended to be a storage room, please confirm by providing a new space plan with intended use of each room or area labeled. 2. Exit illumination with a separate emergency source of power is required for this tenant space. Locate on plan and specify installation. Re: UBC 1012.2 3. Provide note to plan to indicate that tenant space is to be provided with a mechanically.operated ventilation system per UBC Chapter 12. This system must be installed and approved prior to final inspection for this tenant space. John W. Rants, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 i5tiWr�.Yn aw�a>+mr.,Fb a�+tu ck s..uu ay.xl w.asaw.rnvewa Mr. Dana Warren #B96 -0165 June 25, 1996 Page 2 xm: rn•+ N.'+. e.n•.vrarw.e »s's+,�:awr -� svGC+ v...: r+. ux. rn+ �wrrWtMwtrn2�• x.. u+ s�rnanrrw4rNrif' Y!¢: wabWwl... mur. �wawe. �e7 k< n; a. n., �++ dr. s:. r> F+ �e1ct7�+rraurlCtR Please review the listed comments and submit two copies of revised plans that develop. If you have any questions you may call this office, weekdays, between 8:30 AM and 5:00 PM. Inquires regarding the status of your application should be directed to the permit coordinator. Sincerely, Tukwila Building Division Robert Benedicto, Sr. Plans Examiner cc: File /fldr. 0 13:52 FAX 2u' 5320T Department of Labor & Indus - ics Contractor Registration Section PO Box 44450 Olympia WA 98504-4450 Registered name Tu From F625. 036 -000 registration verification 2.95 • nwsK.womanaun•+ Ewa -rts.* n'++ Mm + +o.wr.tnmwwfe.40 2ti65T53207 MA SE(:ALE INC = / - -.- SBP TEMPORARY REGISTRATION VERIFICATION Olympia Headquarters (360)902-5226 FAX (360)902.5228 RegistrQaon 4 11.71/774......o4/ OtrOP. r cgistr:*ann capires isQ2 AAA/ X5707 Contractor: Your Certificate of Reg will be sent from the Olympia office and should be received within 2 to 3 weeks. Please keep this record until you receive your Certificate of Registration. , xocrqpt vaPirc► Than( you CITY OF ETUKWILA AUG 2 7 1996 PERMIT CENTER ',u I 001 DOOR TYPES: 0 O DETAIL C)ELEVATION H.M. 0000 PER / — SCHEDULE LOCATE IN EXIST. BLOCKOUT NOTE: SAWCUT EXISTING CONC. PANEL 0 FUTURE OPENINGS 6 VERIFY EXIST. BLOCKOUT B LOCATIONS PER 0 /A2 PROVIDE EXIT SIGNAGE PER 080 SECTIONS 1012 ANO 1013. 73 REFLECTED CEILING scue SwF: 16" 5/8" C.W.B. ONE SIDE ON 8" MR. STUDS 0 24" O.C. DETAIL 1ST R00F FRAMING 20 GA. DEFLECTION 027 BY ANGELES METAL SYSTEMS ATTACH TO TOP TRACK ONLY - ALLOW MOVEMENT 671811. STUDS AND TOP TRACK. ICIEx7' -0" H.M. INSULATED 0006 FLOOR PLAN SOLE 1 /1G" 1 -0 O TENANT IMPROVEMENT NOTES: E. PROVIDE 2A -10BC FIRE EXTINGUISHERS AT 1/3000 S.F. MAXIMUM - 75' MAXIMUM TRAVEL DISTANCE. FILE COPY C177F3 and omission c. pla not owww to violation neap. code M 0411111.6 RNA* of conwcloh op I PlIAS d' !/ AMMON GO OF RIIRWILA 87/40500 SEP 2 5 19977 IR Wag,1e .. . orre SEP 2 7159? PERMIT CaNTErt e -oX406 W i sheet A2