Loading...
HomeMy WebLinkAboutPermit B96-0181 - SPENCER INDUSTRIES - STORAGE RACKSCity of Tukwila } c., (206). 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 RACK STORAGE PERMIT Permit No: B96 -0181 Type: B -RACKS Category: Address: 18200 OLYMPIC AV S Location: Parcel #: 788890 -0162 Zoning: CM Contractor License No.: EASYUSS08305 Status: ISSUED Issued: 07/12/1996 Expires: 01/08/1997 Suite: TENANT SPENCER INDUSTRIES 18200 OLYMPIC AV S, TUKWILA, WA 98188 OWNER ESTATE OF JAMES CAMPBELL Phone: (206)872 -4680 C/0 COLLIERS INTERNATIONAL, 20206 72ND AVE S, KENT WA 98032 CONTACT KEN DAVIS Phone: 206 395 -2033 8731 SOUTH 212TH STREET, KENT, WA 98031 CONTRACTOR EASY UP STORAGE SYSTEMS Phone: 206 395 -2033 8731 S 212TH STREET, KENT, WA 98031 ** k*******• k********** k********************** * * * * * * * * * * * * ** * * * * * * * * * * * * * * * ** Permit Description: INSTALL RACKS IN EXISTING WAREHOUSE. UBC Edition: 1994 Valuation: 11,800.00 Total Permit Fee: 313.46 .*** k********* k***********- k******************* ** ** * * * * * *k * * ** * *'k ** *. * * * * * * ** Permit'.Center Authorized Signature Date I hereby certify that I have read and examined this permit and know the sane to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. • Signature: Print Name: Date: 71(1 -/9 G Title: 5-1J f This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. DEPARTMENT.` }` = ; DATE !N` :A `'' ' ,.:. �' `RE QUIREMENTS / COMME NTSi� r x A . Plan Review Meeting to c i(0 DATE NOTIFIED • I `_ . • INIT: 4 BUILDING - initial review VW C ONSULTANT: 7 i 6 ( Date Sent - Date Approved - X FIRE - / / �� � N `� I FIREPROTECTION: Sprinklers Q Detectors WA FIRE DEPT. LETTER DATEt : -7/ G j ( � INS PECTOR: INIT: t / O PLANNING -IIEFERENCEFILENOS.: ZONING: PAR /LANDUSECONDITIONS? QYes Q N) INIT: VIINIMUMSETBACKS: N- S- E- W- Q PUBLIC WORKS UTILITYPERMITSREQUIRED? QYes QNo PUBLIC WORKSLETTER DATED: INIT: PZ BUILDING - final review -5. C-( 7 -10 - 9j G, TYPEOFCONSTRUCTION: : wv... � b1*-AQ CERT.OF000UPANCY? oyes *0 UBC EDITION (year): `C1 i Z- INIT: - € BUILDING OFFICIAL 7_10.29/ 7_ / /.- INIT: AMOUNT OWING: CONTACTED . DATE NOTIFIED • I `_ . • / BY: (init) VW 2nd NOTIFICATION BY: (init) 3RD NOTIFICATION BY: (init) PLAN CHECK NUMBER ;R (0 0I <6.) REVIEW COMPLETED CITY OF TUKWILA Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PROJECT NAME ncL SITE ADDRESS l Woc> O SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N/A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. 02/15/96 PROPERTY OWNER rf,,_c L 0 J — h ro,c r Cd el, 6r 'I/ PHONE z /- s 7o - ADDRESS if2 15 C4 /if0r1 - Q 1. t 5 . .reinc 1000 ; c;., /' . 1 ,. ? li /63 ZIP CONTRACTOR f' r 1 l -, j S c `/TONE : 7c .. �. s ADDRESS ' / 3 I J . 7 / 7 7'a (./ . OTHER: TOTAL • aj j (41/) WA. ST. CONTRACTOR'S LICENSE # SITE ADDRESS SUITE # VALUE OF CONSTRUCTION - $ it PROJECT NAME/TENANT ,c�r, err,, _Z /c.,;_7 ;^ EXP. DATE TYPE OF • New Building Li Addition U Tenant Improvement (commercial) U Demolition (building) WORK: Rack Storage 0 Reroof 0 Remodel (residential) 0 Other ARCHITECT BUILDING USE (office, warehouse, etc.) .4 5 NATURE OF BUSINESS: ,,q (',. r < -., 74 1 r 7 WILL THERE BE A CHANGE IN USE? ea No 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: g 5/ q 0O Tenant Space: 4yo0 Area of Construction: S e.,,,.. WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? t"No 0 Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: g S •rinklers P Automatic Fire Alarm S stem PHONE ADDRESS _ ZIP DOW ODUIIIcenrer DOUI&vara, r UI WII VII/1 yo IOO (206) 431 -3670 DESCRIPTION AMOUNT RCPT 0 DATE . BUILDING PERMIT FEE 1. t 5 PLAN CHECK ,/ NUMBER �� if 5 ' APPLICATION MUST BE FILLED OUT COMPLETELY PLAN CHECK FEE BUILDING SURCHARGE ° 4.4° OTHER: TOTAL • aj j (41/) SITE ADDRESS SUITE # VALUE OF CONSTRUCTION - $ it PROJECT NAME/TENANT ,c�r, err,, _Z /c.,;_7 ;^ ASSESSOR ACCOUNT # GL -7 &eG 610 - r)l6 TYPE OF • New Building Li Addition U Tenant Improvement (commercial) U Demolition (building) WORK: Rack Storage 0 Reroof 0 Remodel (residential) 0 Other DESCRIBE WORK TO BE DONE: f`')ft'a // // Ki r s BUILDING USE (office, warehouse, etc.) .4 5 NATURE OF BUSINESS: ,,q (',. r < -., 74 1 r 7 WILL THERE BE A CHANGE IN USE? ea No 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: g 5/ q 0O Tenant Space: 4yo0 Area of Construction: S e.,,,.. WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? t"No 0 Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: g S •rinklers P Automatic Fire Alarm S stem CITY OF TUKWILA Department of Community Development - Building Division BUILDINI PERMIT APPLICATION ; I, HEREBY CERTIFY I HAVE:; READ:; AND EXAMINED THIS. APPLICATION ;AND;KNOW THE<:SAME;' • BE :TRUE AND CORRECT AND - AM AUTHORIZED T.O APPLY FOR <THIS< PERMIT. .;; BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE /4 PRINT NAME ADDRESS e f ' / ? / 7 r j � , h f CONTACT PERSON 1. '.' f . � V r S <" r e ' 3 DATE v r 1 i sy up Snw. PHONE ; S z a3 3 CITY/ZIP y G, s' PHONE APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES (Q 5 COMMERCIAL NEW COMMERCIAL BUILDINGS /ADDITIONS E Completed building permit application (one for each structure rn Asses Account Number <: Two sets (2) of the following 1n Specifications Structural calculations stamped by a Washington State licensed SoPs report stamped by: a Washington State licensed engineer Li Topographical survey I- Energy calculations stamped by a Washington State licensed engineer or architect Legal description Working drawings, stamped by a Washington. State licensed architect, which include: • • Site plan • Architectural drawings • Structural drawings • Mechanical drawings • Elevations • Civil drawings • •. Landscape plan Completed utility permit application (one for entire project) Six (6) sets of civil drawings NOTE:' See utility permit application and checkl for specific utility submittal requirements. • II RACK STORAGE Completed building permit application n Assessor Account Number Two (2) sets of plans, which include: F 1 Building floor plan showing: • Entire space where racks will be located • Exit doors • Dimensions of all aisles Tenant space floor plan showing rack storage layout, aisles and NOTE: Include dimensions of racks (height, width and length), aisles and exit ways on plan. n Structural calculations stamped by a Washington State licensed engineer (rack storage 8'. and over). RESIDENTIAL NEW SINGLE•FAMILY DWELLINGS /ADDITIONS Completed building permit application (one for each structure) II I I Legal description Cn Assessor Account Number II Two sets (2) of working drawings, which include: • Site plan - (on plan, show closest hydrant location. • Foundation plan include access to building, showing • Floor plan width and length of access.) • Roof plan • • Building elevations (all views) • Building cross- section • Structural framing plans n Washington State Energy Code data n Completed utility permit application CI Six (6) sets of site plans showing utilities NOTE: Building site plan and utility site plan may be combined. See utility permit application and checklist for specific submittal. requirements Additional topographical and soils information may be required if unique site conditions. SUBMITTAL CHECKLIST COMMERCIAL TENA IMPROVEME Completed building permit application (one: for each structure: • .Assessor Account Number: Two (2) sets Of. plans,:which include: Site plan ... Location; of. tenant space Existing and proposed perking :Landscape, plan,(11 applicable, i e , change of uee :Overallbuildinp plan • •Tenant location • Use of adjacent (commonwell) tenant ••Overall dimensions ibutiong or square footage Floor plan of proposed tenant space Tenant space Plan:With leach room caballed : •• Exit doors,egress patterns: • New walls; existing wail; and walls to be demolished. Construction details • ;• Cross sections showing wail construction and method of • attachment for floor and ceiling. Structural •caiculadons'stamped• a Washington State fioensed. engineer may be required if structural work is to be done (2 sets) NOTE if any: utility work Is to bo done, submit separate utility permit application and planar: REROOF fl Completed building permit application (one for each structure) Assessor Account. Number - Narrative describing existing roof, material being removed, and - material being installed NOTE: A certification letter is required poor to final inspection and sign off of the permit 11 ANTENNA/SATELLITE DISHES n Completed building permit application Assessor Account Number 1 1 Two (2) sets of plans, which include: Site Plan (showing building and location of;antenna/satellite dish) C Details: antenna/satellite dish and, method of attachment • Structural calculations :stamped by a Washington State licensed engineer may be 'required RESIDENTIAL REMODELS Completed buildng permit: application (one for each structure n Assessor Account Number Two (2) sets of working drawings,, which include • Site plan :. • Foundation plan Floor plan • Roof plan • Building elevations (all views Building cross-section •:;Structural framing plans , NOTE;; If any utility work is 19 be done provide; utility permit application and plans must be ; submitted : :: REROOFS Completed building permit application (one for each structure n Assessor Account Number in Narrative describing existing roof, material being removed, material being installed . NOTE: A certification letter is required prior to final Inspection and sign- off of the permit *A *Aol•k4*4A.l,w*st*.A* *l. *• k, k** 4A* 4* AA***, 4h .iat,t *Ak*Ak4.k* ** 1.&dc ** CITY OF TUKWILA. WA � - iz TRANSMIT :4 * ** *A * * * * * * * * * * ** * * * ** *A k *d• .t * *k * *kk* *** * * *A * * *A * * **k* * * * ** TRANSMIT Number: 96004144 Amount: 31.3.416 06/25/96 :t7:00 Payment Method: CHECK Nctat,iari: EASY LIP SHELVING Iriit: SL.E3 Permit No: 1396-0181 Type: E3 -RACKS RACK STORAGE PERMIT Parcel No 788$390- -0162 Site Address: 18200 OLYMPIC AV S Total Fees: 313.46 This Payment 313.46 Total ALL Pint;: 313.46 Balance: .00 •.t * * *ot * *:t ** * * *•* * * * ** * *A *' * *:ti * * * *et *.t ** * ** ** * * ** *•k * *•A*:t3 *vt* ** * ** * ** Account Code 000/322.100 000/345.630 000/386.904 Description E3U11.tDI.NG - NONRES PLAN CHECK - NONREES S'f ATE BUILDING SURCHARGE 0 Amount 187.25 121.71 4.50 J 0762 06/26 9617 TOTAL 313.46 Needs shift inspection Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature -4 11 -- w• City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT Permit No. Ng/ I FINAL APPROVAL FORM Project Name Address )P.2.0r) 01( c. Av • S Retain current inspection schedule Approved without correction notice Approved with correction notice issued Thomas P. Keefe, Fire Chief FINALAPP.FRM T.F.D. Form F.P. 85 John W. Rants, Mayor Suite # Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 Address.: 18200 OLYMPIC AV Suite: Tenant: SPENCER INDUSTRIES Type: B- RACKS 2 Parcel #: 788890-0162 62 •k 'k ' . •4 'k '4 * •4 •4 'k •A '4 k •k * '4 * * 4 •4 4 •t :4 'k •4 •k •4 4 •4 'k k '4 •A 'A '4 * •4 •k A k 4 '4 'k 4 '4 '4 4 4 •A :4 'k 4 4, •4 4 •k 'k ,4 •k '4 •4 4 •4 4 4 A :4 •4 :4 .4 4 Permit Conditions.: 1. No changes will be made to the plans unless approved by the Architect or Engineer and the Tukwila Building Division. 2. All permits, inspection records., and approved plans shall be available at the .iob i.te • prior to the start of any con- struction. These document:. are to be maintained and avail- able until final inspection approval is granted.. 3. All structural welding ;.hall be done by W.A.B.0. certified welders and special' inspected (UBC - '=see. 306(a)5) 4. When spec1al inspection is required either the owner, architect or. engineer shall notify the Tukwila' Building Division' of appointment of the inspection agencies prior to the first.building inspection. Copies of all special inspection reports. shall be • submitted to the Building Division in a timely manner. Reports. shall conta;n.atidress, project name, permit number and type of inspection being performed.. 5. The.special inspector shall submit a final signed report stating whether the work requiring special inspection was., to.- the bes t of. the inspector's knowledge, -in conformance with approved plans. and Specifications and the applicable workmanship provisions, of the U13C . 6. Ai 1. con_ `Cruet ion to be done in conformance with approved i plans and requirements of the' Un i f or:m B u i l d i n g Code (1994 Edition) •as amended, Uniform Mechanical Code (1994 Edition), and.W'ashington: :state Energy Code (1994 Edition). • 7. The :a,l lowable rack loading shall be conspicuously posted on the - racks and sionage to indicate that this is not to be exceeded. Posting of this signage is a condition of final inspection approval. 8. Validity of Permit. The issuance of a permit or approva 1 of plan_, specifications, and computations shall not be con- strued to be a permit for or an approval of any 'violation of any of the . prov i s . i ons of the b u i l d i n g code or of any other ordinance of the jurisdiction. ' No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. CITY OF TUKWILA 5� Permit No: 896 -11131 Status: ISSUED Applied: 06/25/1996 Issued: 07/12/1996 Project: r , Type of inspRction: Address:! 1 S .=,1 O() C)..�.. ,.,,,, ..G Q..,.. Z Date called: c" Ja Special instructions:u ° Date wanted: Y )� / ', R \-�- }1` Lai, i; x., c , UA ' . Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 ANL Approved per applicable codes. Inspector: 1 INSPECTION RECORD R etain a copy with permit &96, _D►?► PERMIT NO. Corrections required prior to approval. Dater 1 0 (206) 431 - 3670 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: , I) -- rAlitDC (.4.4 e ( 04 1 S/( ,J A Special instructions: 67gP-1= \ O tAiCAT S Or 50,5a... 'I IA A , i Phone No.:( .... (22g i . . ,... 1 t-.1 s 4t 1....0:H-r—iE22L:i___ ft-A_ i 0..4 i . ,..,,... c,4 .....-....-...„,..,.. 4,....... . .,:t. Mac.kg_ twolAsTizt Type of inspection: Vim 0 004 ot_ Av 5 Date called: 7-2.-2)0\1, Date wantedi , 23... fc cr „. Special instructions: 67gP-1= \ Requesters j4c ()vim Phone No.:( .... (22g INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector: INSPECTION RECORD Retain a copy with permit Approved per applicable codes. -`) Date: 7 ■3 - oig 1 PERMIT NO. (206) 431-3670 Corrections required prior to approval. [1 $42.00 REINSPECT ON FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 14g . 1 CITY OF TUKWILA APPROVED JUL 1 0 1996 AS NOTED BUILDING DIVT3ION rtLE COPY undcrc:_ 7:d C... 11.7.n C'. subject to c :Tc73 and omissions c.,.: 1 pla.rs does not authodee the violation o _p J code or ( NOW 01 ntractoe ! cc; y cf approved pian i/d — -- -."""a,.r Ly /(e<h Date Permit No. r .r ' s 7 r E /2.9:' E LE( //T'oAv r -. e_ ATE t S / &'r>e 3 , r � Iv L E. j .. - rN `I - E2 L A4c.r_ IAA L LE AC K x 9,6 x I2. NO C TIE Sc 'O; f< WIT OUT PRIOR OF Vti� PROW.'._ OF TUKWILA BUILDIN OTE: r :^ WILL REQUIRE A NEW PLAN S s( L Ar :. r.' r; , ;� ADDITIONAL PLAN REVIEW FEES. I RECEIVED ' CITY OF TUKWILA JUN 2 5 1996 PERMIT CENTER 1' 28$ 24 z • o • QAc lou ►? sh ov i x2 1 148 1 CITY OF TUKWILA APPROVED JUL 1 0 1996 AS NOTED BUILDING DIVIBION t"ILE COPY 1 undcrct: nd t . . .3 plc.: c • • i .. • X 29 : . -- - . D ts 4 t3. -n ff__ • • • I k L. /A L. L , yprc ELEvel-r/0A) � • t • 1: i. fi 1 ; • 3 x 9,6 i 11 t2 K • • z88 24 , EV:i iS • NO C • ES S ; LL BE MAr)E TO Y . THE s i : OF WORK WITHOUT PROVE'•.'_ OF TUKWILA BUILDIGaWISI ' z� OTE: r,eVl 'ror!s WILL REQUIRE A NEW al AK, �1L \\I • JUN 2 5 1996 RECEIVED ' CITY OF TUKWILA Z O F 2.+c • • . PERMIT CENTER • • Dear Sir: City of Tukwila Fire Department Review Control #B96 -0181 (512) Fire Department Thomas P. Keefe, Fire Chief July 3, 1996 Re: Spencer Industries - 18200 Olympic Avenue South The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire 'extinguisher coverage throughout. 2. Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. .(UFC 1204.1) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) 3. The critical storage height for high -piled combustible stock in closely packed piles is 12 feet. (UFC 9.110) Storage above 12 feet may necessitate increasing the sprinkler density to extra hazard and adding smoke removal capabilities. (UFC 8101) (NFPA 231) To use any building or portion thereof exceeding 500 square feet for the storage of high -piled combustible stock. A floor plan showing the dimensions and location of the stockpiles and aisles shall be submitted with applications for such permits. (UFC 8101) In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 231C 4 -3.1) John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phones (206) 5754404 • Fax (206) 5754439 Page number 2 High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible materials on pallets or in racks more than 12 feet in height. For certain special- hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (UFC article 2, sec. 209 -H) Maintain minimum 6" longitudinal flue space between back to back racks. (NFPA 231C) Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 231C, 3 -2.3) Storage may not be closer than 36 inches in all directions to ceiling -hung "Space or Unit" heaters. (UFC 1109.2) Storage may not be closer than 18 inches below sprinkler heads. (NFPA 13, 4 -2.5 and NFPA 231.5 -1) 4. Warehouses designed for high -piled stock shall establish and maintain aisleways of not less the 44 inches to provide access to all exits and fire department access doors. (UFC 8101.6.3) 5. This review limited to - speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575 -4439 Page number 3 Yours truly, c Sl( '. The Tukwila ire Prevention Bureau cc: TFD file ncd John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 -4404 • Fax (206) S75-4439 C POE Engineering, Inc. CIVIL & STRUCTURAL ENGINEERING/CONSULTING 400 WEST GOWE STREET, SUITE 310 KENT, WASHINGTON 98032 (206) 859-5121 • FAX (206) 859.5207 June 25, 1996 Easy Up Storage Systems 8731 South 212th Kent, Wa 98031 Attn: Mr. Ken Davis RE: Spencer Industries Racking 18200 Olympic South Tukwila, Wa (P /E Job No. 96 -060) Dear Ken: A seismic overturning analysis has been performed on the above referenced storage racking using the geometry & loading conditions supplied by Easy Up Storage Systems (shown on sheet 1 of the attached calculations). The racking consists of (1) basic geometry and the analysis was performed to review the overturning stability and foundation requirements only. The racking itself is per the manufacturer /supplier. Allowable rack loadings should be conspicuously posted and not exceeded during use. Based on these parameters, the racking will require the foot plate and bolting as shown on sheet 4 of the attached calculations at the base of every column. This foot plate detail is capable of resisting the overturning forces as required by the 1994 UBC Standards for this racking system. Please call if you have any comments or questions. Sincerely, POE Engineering, Inc. ,- Alan F. Poe, P.E. attachment C1 APPROVED TUKWILA JUL 10 1996 AS NOTE BUILDING DIVTS1 RECEIVED CITY OF TUKWILA JUN 251996 PERMIT CENTER POE Engineering, Inc. Civil & Structural Engineering/Consulting 400 West Gowe Street, Suite 310 Kent, WA 98032 (206) 859 -5121 FAX (206) 859 -5207 - v(L. SHEET NO / OF CALCULATED BY DATE G- Z` /+" CHECKED BY DATE SCALE JOB �C�✓CCIZ G C$:S � �l� /99c • Lc' LOA 7-& LetieL Z 3 TjouSTI2ICS PAL(-ET RACIf1^✓G I C.G. C G• 96" i " 2 c ' , 4 / T ( / € L . . ' c / [ I G'I r CIbs ) Z') 00 no 0 JO J & 1 . . z')00 52" ' 5 1" Ri C! <I C T3 C.. n /-?G c' A/6 Z 9Oa CO s r '1- y6/ 6ASE ) POE Engineering, Inc. Civil & Structural Engineering/Consulting 400 West Gowe Street, Suite 310 Kent, WA 98032 (206) 859 -5121 FAX (206) 859 -5207 9G -0 / SHEET NO Z OF CALCULATED BY DATE JOB CHECKED BY DATE SCALE QCs/ C2irerzrA SCr• I c Z3Ne 3 199'1 L'&G S' / SLAG& 7` = 3000 ps, c = 36 ks. / }LLO(.. Sv1L (31ZG 7 000 PSG' V : al( w Z = . 1' 0 C✓ = 14800 1 CASE I ALL LEvELS C- o:40Co L✓ : I 0,goV 'Ls Z TUT' 3 L e.t./ S LU:tDC'O% LJ ' 8 /r)o ICs 3 - P Z Lave LS (..oto c✓ : L./ - 7 p L OA2L �� c r _ z r 7vv !c, /�� 31( !a e� — (1 13 ins E CASE 41 I i71 s I 0v7 O ' = vS E c 4SC _ I L E've c. ( L ) (,, (a) c.,, OF CeiVrC -LTi I 2',2a /. 7.19' / 9, y /kr,L. ie(5.6 k Z z ay h: //J..o' 31.3z4r,L Zw,.V a z 7oa /I. 15.43' •/l. G 6 k t c74. 3Z /. / 4./ 2;>00 /1. 19.Z�' SZ -"i /1„-:o.ed • ivy Y kr' /// 3 V = Vc% 4, 1.i, -s) ; zzl.k CASE Z (..EvEl. (�) c 00 1.,: G.4:1.. V. Z Z.70 /1 • 3/. 3 CA- Z09. Z Zr>va /s yl, 66114 Z`. 8,5 2.70 (9.26' 9 ooki4 3 5y V ° 1113 16s V ' 0'35.3 Iles v = 556.9 //.4 Z `//65 AWN {fiN:iN.rt3'.kt{.yv POE Engineering, Inc. Civil & Structural Engineering/Consulting 400 West Gowe Street, Suite 310 Kent, WA 98032 (206) 859.5121 FAX (206) 859.5207 JOB 2‘ - &"i SHEET NO OF - v 9 / CALCULATED BY ' DATE 6 -J y v '" CHECKED BY DATE SCALE CASE 3 L a i n _ (c (.; ( /) 1, 3 Z ?oo Z'?00 19,7_6' yr.GG a Zca, 5Z.00 lP 303. Z # 9- 3 .66/44 - 554.5 CASE/ LEvEL (0 GJ: (R.) In, c% V,. y Z7 19, 26' �-`Z.0 1(4 Z ?B. `/ `4 ✓ OvERTVr z,vI / f-/exvac.. ' CASE 1 c,4 SC z CA SF CASE 4./ O V C RrV, ?.L I,`- 1 it 0,1-t - L t11. = L6 .55�k 1 RCSist' G � rc�MC�T (R���� = �V l J = t i x))( z� 1 4 ) ,r I� ra 67 07"; - =19.gb /Jo REwtI = Ir C,- -r I ' '�)I.5 — *` / .4z 3 )0 C = 13. ' Z -r - f< /. : /WO f ,v1.A/ cJp 1.1F-1— ( ._ JOB 96- (Ai- POE Engineering, Inc. SHEET NO y OF � Civil & Structural Engineering/Consulting 7" (---Z(-/- 400 West Gowe Street, Suite 310 CALCULATED BY DATE Kent, WA 98032 (206) 859 -5121 FAX (206) 859-5207 CHECKED BY DATE SCALE )AA.\' ti7t„ L o A- 12 1 4 /515 )1 Fa7 PLJ r (NT:„) i/2„ EY p vim. L71 I `.,) 3 ,I 7_ .. `, i GI i v c. :pE�' 4L 0. S PACT /0•■•• ?Air-,TALL j rEa? /v)r -r:, 1 AL.L / I.ZS 1 1 .25 pu . cP C. C v ,>c. L • 9.9/Y' = Z- - /Snsl (ZY ern, )( ';���2.3 Iv,,; G2 / v rZ ,4 1,.! l� GC . t [x'417 ac 9, 9/4/ IC 0 I,zS 11,2 • CjT / - ( 6. `5 Ffl� 1 • POE Engineering, Inc. Civil & Structural Engineering/Consulting 400 West Gowe Street, Suite 310 Kent, WA 98032 (206) 859 -5121 FAX (206) 859 -5207 (CUB - 7) CASE 1 : 1 ' S OR 1` ' 1' � ST4' P S. toe - M/ G � „ V (3 4.,0.0) =.3(.59 -3 / 13 / ' TN /C / TAG,1 rC ) 1/ - L X u ! l 67)76- 7 ? C AR( �Lcc� .; (;lz6) (. 33 ez.0/(P=Y1.33)( -s 64) z 6 (( s JOB ',& j v 0 SHEET NO 5' OF 6 D / CALCULATED BY DATE G Cs CHECKED BY DATE SCALE Fe F >( y '/) 36 CVO pi'� .L ifs k 1 .3 3 ) • Ca-rzL)(s-tZ‘...) = 3 ye._Z z6L , -/v =(� �3)((tf'/s� ) Z s� L + C L — J2 Z =O 5.5 (, . POE Engineering, Inc. Civil & Structural Engineering/Consulting 400 West Gowe Street, Suite 310 Kent, WA 98032 (206) 859.5121 FAX (206) 859.5207 JOB ?�- ()KC; SHEET NO. 6 OF / 6 CALCULATED BY DATE - ZS- ,6 CHECKED BY DATE SCALE o f LA1 (co ,$) /- /LLvL, c i �o D ec . "s o � f�uPitnee �.5 J 3uvc.) [, s , CJ. s z � , 21 r = I L /L./0 (it/ (z) /z. Pr chit: 2S SP GE a AT S. 1�1A% AT 1•C •GC.. PL I trr. -c r: / -', • 1P.-1t L 47 •4.) ,. 1 r t . , 0 4 1% ,s/4 r I t_ /r.e 1 / ? . ~1. C/ 1 V'',9C / ' r, arc ('z) 1 - 1 c_ G1 c„ / 3 14 .. v' f.,v p( iA c7/ I6'/'l,� c� USE n,4(. %G Cc. Cr Y l" vL'L ;') , ., " 1 l'v /'cc, " 4 /:t.S /��G� /P� i'3? t. ; ?oJ /4 a ` L L •L% .-JUN-i28-9E OS:OS:PROM: EASY UP ID: • PAGE 2 EP /ED JUN 9 , 3 1996 , , 1.." AU!