Loading...
HomeMy WebLinkAboutPermit B96-0190 - OLD NAVY - TENANT IMPROVEMENTCity of Tukwila ( C. (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: B96 -0190 Type: B -BUILD Category: ACOM Address: 300 ANDOVER PK W Location: Parcel #: 262304 -9119 Zoning: C2 Type Const: II -N Gas /Elec: Wetlands: Water: N/A Contractor License No.: FISHEDI141PT Status: ISSUED Issued: 08/07/1996 Expires: 02/03/1997 Type of Occupancy: STORE Slopes: N Sewer: N/A TENANT OLD NAVY STORE 300 ANDOVER PK W, TUKWILA WA 98188 OWNER SEGALE M A INC PO BOX 88050, TUKWILA WA 98188 CONTRACTOR FISHER DEVELOPMENT Phone: 415 468 -1717 1485 BAYSHORE BOULEVARD, SAN FRANCISCO, CA 94124 CONTACT JAMES FURRATE Phone: 865 -0450 1035 156 AV NE, BELLEVUE WA 98007 *k k*** k*k kk***** k*** kk* kkk* k** k* k*********** * * * * * * * * * * * * *k** * * * ** * * * * * * * * ** Permit Description: REMODEL EXISTING SPACE. SETBACKS Units: 001 Front: .0 Back :, .0 Buildings: 001 Left: .0 Right: .0 Fire Protection: SPRINKLERED UBC Edition: 1994. Valuation: 110,000.00 Total Permit Fee: 1,550.96 * k*'k k******* k** k*************k k****** * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ** A 112 Permft'Cente uthorized Signature Date F-7-q I hereby certify that I have read and examined this permit and know the same to.be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction . or the performance of work. I am authorized to sign for and obtain this b i'lding rmit Signature: Date: 7 - " -I Print Name: _3i_44q I ), iz4iZ_ Title: .7'lfi� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. DEPARTMENT ;� DATE L APPROVED` , R EQUIREMENTS /CO ti = .i:( Plan Review Meeting 1 1 " 3 ' g o -"�p' INIT: q it BUILDING - initial review -___)Q13 7.- 1(0 _`t& R CONSULTANT: Date Sent - Date Approved - Z. (ROUTED) /" FIRE '7- 1/0--% / h LJ(CI �r; I " FIREPROTE Sprinklers Detectors Q WA FIRE DEPT. LETTER DATED: 7/7 ce , INSPECTOR: [, 0 , INIT: � .R-- I l g PLANNING • 7 -26 ,--7 /? �/� 6 ZONING: -7-1)6._ pAR/LANDUSECONDITIONS? Yes 0 No hEFERENCEFILENOS.: 9, 9 ( - 0 INIT: k (-) MINIMUMSETBACKS: N- S- E- W- PUBLIC WORKS -25 �_q,_ - W r f/ l9G UTILITYPERMITSREQUIRED? 0Yes cz No PUBLIC WORKS LETTER DATED: INIT: 4 K BUILDING - final review 7- 25 -16, TYPEOFCONSTRUCTION: CERT.OFOCCUPANCY? °Yes 0 No UBC EDITION (year): INIT: :, Ag UILDING FFICIAL 7 Z5 -9 Co ""),g -`il, INIT: `6"= AMOUNT OWING: V (1 ! " � il C� 16 r CONTACTED 1 t � t Z r n , �-�C ((� �,� DATE NOTIFIED -"�p' (7 V (� ii BY: ( /nit.) -___)Q13 2nd NOTIFICATION BY: (Init) 3RD NOTIFICATION BY: (init) PLAN CHECK NUMBER Pf1 o - p l Div CITY OF TUKWILA Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. REVIEW COMPLETED F\L0 co u6 Building Permit Application Tracking PROJECT NAME OL-b NNy G�g-F SITE ADDRESS Soo ANN(>I - Pv_ 2/■1 SUITE NO. (000 INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N/A ", date and initial. 02/15/96 OJUU JOUWGunter DOwevara, / uKwna vvH uo IOa (206) 431 -3670 DESCRIPTION AMOUNT RCPT 0 DATE BUILDING PERMIT FEE PLAN CHECK FEE ` '7 . 1r1 1 : `1-1� to PLAN NUMBER CHECK ( �J J ` 9(') 6:\ APPLICATION MUST BE FILLED OUT COMPLETELY BUILDING SURCHARGE OTHER. `: TOTAL - .: i i W. It ; -: SITE ADDRESS SUITE # 300 Andover Park West 600 VALUE OF CONSTRUCTION - $ (B) $110,000 (M) $48,000 PROJECT NAME/TENANT Old Navy Store ASSESSOR ACCOUNT # 7-6, .Z 30 4 — `� ) 1 9 TYPE OF • New Building • Addition • Tenant Improvement (commercial) • Demolition (building) WORK: ❑ Rack Storage ❑ Reroof ❑ Remodel (residential) ❑ Other DESCRIBE WORK TO BE DONE: Remodel of existing retail tenant space to include arch. & mech. work. BUILDING USE (office, warehouse, etc.) Retail sales of clothing RETAIL * * * * ** NATURE OF BUSINESS: Retail sales of clothing WILL THERE BE A CHANGE IN USE? ❑ No ❑ Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: Tenant Space: 1 4, 1 70 Area of Construction: 1 4, 1 7 0 WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? ❑ No ❑ Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: ❑ Sprinklers ❑ Automatic Fire Alarm System PROPERTYOWNER Segale Business Park /La Pianta Ltd. PHONE 206- 575 -2000 ADDRESS Andover Park West #200, Tukwila, WA. °P98188 CONTRACTOR F Development PHONE 415- 468 -1717 ADDRESS Bayshore Blvd., San FRancisco, CA. 94124 °P94124 WA. ST. CONTRACTOR'S LICENSE # FISHEDI1 41 PT EXP. DATE ARCHITECT H eath Architect PHONE 510 - 865 -8663 ADDRESS 1115 Atlantic Ave., Ste. 101, Alameda, CA. ZIP 94501 CITY OF TUKWILA Department of Community Development - Building Division • I HEREBY GEHTIFY;THAT I:FIAVE READ'ANO THIS.APpLCCATIQN KNOW `THE SAME'. :BE TRUE AND :CORRECT, AND:.I AM: AUTH IZED''TO.' PPLY FOR THIS PERMIT SIGNATUR PRINT N E BUILDING OWNER OR AUTHORIZED AGENT Jame ADDRESS 1035 156th Ave. CONTACT PERSON James Furrate urrate JUL 0 1 1996 PERMIT CENTER BUILDINfl PERMIT APPLICATION • • DATE J 1 )CR[-) PHONE 206 -865 -0450 6 -0063 CITY/ZIPBellevue 98007 PHONE 206-865-0450 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architecVengineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department o cBINtitty Development Building Division at 431 -3670. CITY DATE APPLICATION ACCEPTED OFTtJKWILA DATE APPLICATION EXPIRES 10/22/G3 COMMERCIAL NEW COMMERCIAL BUILDINGS /ADDITIONS n Completed building permit application (one for each structure El Assessor Account Number Two sets (2) of the following: Specifications Structural calculations stamped by a Washington State licensed engineer Soils report stamped by a Washington State licensed engineer Topographical survey n Energy calculations stamped by a Washington :State Licensed engineer or architect Legal description -1 Working drawings, stamped by a Washington State licensed • architect, which Include: • Site plan • Architectural drawings ,. • Structural drawings • Mechanical drawings • Elevations '• Civil drawigs • Landscape plan • n Completed utility permit application (one for entire project) Six (6) sets of civil drawings NOTE: See utility permit application and checklist for specific utility submittal requirements Entire spaoe. racks will be located • Exit doors • Dimensions of all aisles : Tenant spac° floor plan showing rack storage layout, aisles and exits. I 1 RACK STORAGE D Completed building permit application • Assessor Account Number Two (2) sots'of which include: Building floor plan showing I . NOTE: Include dimensions of racks (height, width and length), aisles and exit ways on plan Structural calculations stamped by a Washington State licensed engineer (rack storage 8' and over) RESIDENTIAL NEW SINGLE- FAMILY DWELLINGS /ADDITIONS n Completed building permit application (one for each structure) II Legal description n Assessor Account Number Two sets (2) of working drawings,' which incitide: • Site plan .._._._r (Cm plan, show closest hydrant bcadon. • Foundation plan include access to building, showing • Floor plan width and length of access.) • Roof plan • • Building 'elevations (all views) • Building cross - section • Structural framing plans n Washington State Energy Code data II - Completed utility permit application n Six (6) sets of site plans showing utilities NOTE: Building site plan and utility site plan may be combined' See utility permit application and checklist for specific submittal requirements. . Additional topographical and soils information may required if unique s/to conditions. SUBMITTAL CHECKLIST Locati of tenant ape Existing and proposed parking.:: • Landscape plan (if applicable, •i e , change of use Overall building plan • Tenant location • Use of adjacent (common Wall) tenant • C±verall dimensions of building or square :foota Flew; plan of propo tenant spa • Tenant space plan' withuse o each roam (s helled :•' doors; ogreae patterns • • New walls, existing wall, and walls to bedamolished, Construction details • Cross sectlons showing wall construction and method of attachment for floor and ceiling.. Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) NOTE: If any utility work Is to be done, submit separate udlity permit application end plans. REROOF Completed building permit application (one for each structure) n Assessor . Account Number r- Narrative describing existing roof, material being removed, and material being installed • NOTE: A certification letter is required prior to final inspection and • off of the permit.: ANTENNA/SATELLITE: DISHES n Assessor Account Number Two (2) sets of plans, which include;. n Site Plan (showing building and location of antenna/satellite dish n Details antenna/satellite dish and method of attachment n Structural calculations stamped by a Washington State license engineer may be required RESIDENTIAL REMODELS Completed building permit application (one for each structure ) f] Assessor Account Number n Two ( sets: drawings which include. Sitp plan • • fioundatkin pir�i� •: Floorplan • Roof plan Building elevations (all wows Building ,cross- section • Structural framing plans; NOTE If any utilitywork is to be done prov►de utility: permit application and plans must .be. submi and I I Completed building permit application' ., .. REROOFS n Completed building permit application (one for each structure 1 1 Assessor Account Number Narrative describing existing roof, material being removed, material being installed NOTE: A certification letter 1s required prior final inspection and sign • off of the permit.::. A*** s\* k* 4* t*• A* A *o\4 * *4*•.'. * * *4* * *s4 * * *k. \ *. *** s4s \sk * * *A*JA * * **•A• * * *: 1380 -O c CITY OF TUKWILA, WA TRANSMIT * h*• skk*** 4. A *A * * *: \*'4 * * * * *A * * ** * * *A ** *A * * * s\A * * *kks \ *h *. k.4*•ki,•l• *s\k*s\ie TRANSMIT Number: 9600438 Amount: 609.21 07/01/96 12 :13 Pc3ment Method: CHECK Notation: FISHER DEVELOP, knit: SMC Permit Riau B96-0190 Tyne. B-•BUILD BUILDING PERM] :T Total Fees. 1 ~ 350.`.3ar This Payment 609.21 Total ALL Pmts,: .60.9.21 Balance: 941.71 *** AA* o4** it•>\****** s4A * *si *h *A* * * *; \•A••A *•hrkAA *.t k* . * * * * *:\ *ck **s\ * *si* * *:k•k \* Account Code Description Amount 000/922.100 BUILDING - MOMRES 609.21 0874 07/01 9619 TOTAL 609.21 CITY OF Tltl(WILA Permit No: B96 -0190 Address.: 300 ANDOVER PK W uite: 600 Tenant: OLD NAVY STORE Status: ISSUED Type: B -BUILD Applied: 07/01/1996 Parcel #: 262304-9119 Issued 08107/1996 1 996 44.4 444•* 44144 *444•4•4'4444.4444'.4**444k44k 4444444444 44 '•4-.44.44.4 *•4444,4 Permit Condition..: 1. PRIOR TO FINAL SIGN OFF APPLICANT SHALL RETURN METRO SEWER USE FORM TO PUBLIC WORKS FOR PROCE'S'SING. 2. No changes wi 11 be made to the plans Lunless approved by the Architect or Engineer, and the Tukwi 1a Bui lding Division. Plumbing permits shall be obtained through the Seattle-King County Department of Public.Health. Plumbing will be inspected by that agency, including a l l gas p i p i n g (296 - 4722)'. 4. Electrical' permit: shall be obtained through the Was.h1naton State Division of `Labor and Industries and all electrical • work will be inspected by that agency' (248-6630). 5. All mechanical work shall be under separate permit issued by the City Of Tukwila. • 6. All'p,ermits, inspection records, and approved plans shall be ava.i lable at. the Job s i t e prior to the start of any con- struction.. These documents are to be maintained and avail- able until final inspection approval is granted. 7. All structural welding shall be done by W.A.B.O. certified welders., and special inspected (UBC - Sec. 306(a)5). 8. Bolts installed in concrete shall be special inspected (UBC - S`ec. 306(a)2) 9. Whe special inspection is required either the owner, architect or engineer shall notify the Tukwila Building Divi ion 'of appointment of the inspection agencies prior to . the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name, permit number and tape of inspection being • performed. 10. The special inspector 'shall submit a final signed report stating whether the work requiring special inspection was, to the best of the inspector's knowledge, in conformance with approved. plans and specifications and the applicable workmanship p r o v i s i o n s of the UBC. 11. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements• for Seismic Zone 3. 12. Partition walls attached to ceiling grid must be laterally braced if over eight (3) feet in length. 13. Readily accessible access to roof mounted equipment is required. 14. Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identi- fication showing the fire performance rating thereof. 15. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1994 Edition) as amended, Uniform Mechanical Code (1994 Edition), and Washington State Energy Code (1994 E d i t i o n ) . 16. Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con - strued to be a permit for, or an approval of any violation of anv of the provisions of the building code or of anv 4:4*. other ordinance of the jurisdiction. No permit presuming to • give authority to j " v l a to or cancel the provi ns of t h i s code shall be val i1 17 There shall be no occupancy of the building(v;) until the final inspection has been completed by the Tukwila Building Inspector. 13. A CERTIFICATE OF OCCUPANCY WILL BE REQUIRED FOR THIS PERMIT. :%* **k* *4*doJr:k **0•* **A Ak k:*- a *N*4 *A *•A*A**A*•kA*A *k CITY OF TUK:WILA, 1►A Ti`r'Ii':"Ml'7' *k* * *A *Ak* * **A *A * * * *:k* *•kk•. : * *•1. l4* *A*. •k. *k•A * A* **•kh: }*d** 4•* TRANSMIT dumber: 89600459 Amount: 941. ?5 08.'0 12 :23 Payment Method: CHECK Notation: FISHER DEV Init: I;JP Permit No: B96-0190 'dyne: B -I3UILD BUILDING PERi4IT Parcel No: 262304.9119 Site Address: 300 ANDOVER PI( (4 Account Code Description 000 /3:2.100 BUILDING - NOI!RES 000/345.830 PLAN CHECK -- NQNRES 000/386.904 STATE BUILDING SURCHARGE 0 Total Fees: 1.550.96 This Payment 941.75 Total ALL Pmts: 1,550.96 Balance: .00 *•kA **** * * **A*4.** ***4,•k *k* 011 ** * * #1. * *•kA *:4 * *k* * * **•k* **A *A * * *y4•k1•A.A>1* Amount 328.04 60`_x.21 4.50 1961.' +Q7 /O13 9617 TOTAL 941.75 Project: /`/ ' ` f Type of inspect _� Date called: Address: Special instructions Date wanted: 3 Z -S�l i m Requester: Phone No.: 1 INSPECTION RECORD - Retain a copy with permit !Ono 5/9b INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 COMMENTS: II e 4 . ti el e.; I Ste e Inspector; Approved per applicable codes. Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: (206) 431 - 3670 Corrections required prior to approval. City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 262304 -9001 Permit No: Address: 300 ANDOVER PK W Status: Suite No: Issued: Location: 300 ANDOVER PK W #600 SPACE C; OLD NAVY Expires: Category: NRES Type: MISCPERM Zoning: C2 Const Type: Occupancy: Gas /Elec.: UBC: Units: 000 Fire Protection: Setbacks: North: Water: N/A Wetlands: Contractor Licence No: OCCUPANT OLD NAVY 300 ANDOVER PK W *600, TUKWILA WA 98188 OWNER SEGALE M A INC PO BOX 88050, TUKWILA WA 98188 CONTACT DANA WARREN PO BOX 88050, TUKWILA WA 98138 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALLATION OF ONE PERMANENT 1.5" WATER METER FOR TENANT SPACE C(SUITE #600, OLD NAVY STORE). METER BOXES AND ALL WATER PIPING COMPLETED UNDER SEPARATE PERMIT PW94 -0021. ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ .00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: JJS Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Flood Control Zone: N Hauling: N Start Time: Land Altering: N Cut: Landscape Irrigation: N Moving Oversized Load: N Start Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: Storm Drainage: N Street Use: N Water Main Extension: N Private: ********************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ ********** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorized Signature:__ Signature: MISCELLANEOUS PERMIT .0 South: .0 East: .0 West: .0 Sewer: N/A Slopes: N Streams: Phone: 206 575 -2000 Size(in): .00 End Time: Fill: End Time: Public: (206) 431 -3670 MI96 -0006 ISSUED 09/23/1996 03/22/1997 AM14/4 Date : --����� I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. Print N ame:__ 14 _La,,L =.ta This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. `' METER SUPPLEMENT DEVELOPMENT PERMIT Permit No: MI96 -0006 Status: ISSUED Site Address: 300 ANDOVER PK W Location: 300 ANDOVER PK W #600 SPACE C; OLD NAVY WATER METER A TOTAL WATER METER FEES: $629.50 PUBLIC WORKS ENGINEER APPROVAL: JJS s. Applied Date: 09/10/1996 Issued Date: 09/23/1996 WATER METER B WATER METER C Water Meter Type: PERM Water Meter Size: 1.50 .00 .00 Quantity: 1 Work Order No: 5106E Connection Fees: $225.00 $.00 $.00 Install Deposit: $350.00 $.00 $.00 Add'1 Install Deposit: $.00 $.00 $.00 Plan Review Fee: $10.00 $.00 $.00 Inspection Fee: $ $.00 $.00 Water Turn On Fee: $25.00 $.00 $.00 Special Assessment: $.00 $.00 $.00 Other Fee: .00 .00 $.00 City of Tukwila Department of Public Works NOTIFICATION OF UTILITY PERMIT ACTION TO: PERMIT CENTER FROM: PUBLIC WORKS ENGINEERING DATE: SEPTEMBER 16, 1996 SUBJECT: OLD NAVY Segale Retail Space C /Permanent Water Meter 300 Andover Park West Suite #600 Project No.: PRE92 -027 Plan Check No.: B96 -0190 Activity No.: MI96 -0006 Contact Person: Mr. Dana Warren Phone: (206)575 -2000 THE FOLLOWING PUBLIC WORKS PERMITS HAVE BEEN APPROVED FOR ISSUANCE IN ACCORDANCE WITH THE PLANS APPROVED ON September 16, 1996: MI96 -0006 Permanent Water Meter(1.5 ") 625,00 Total Fees: $625.00 Two copies of the confirmed Utility Permit Application with a set of plans are attached for inclusion in the permit file. JJS /mv Attachments a/s C.F.: PW Utilities Inspector (copy of UPA, application and plans) Development File (copy of UPA, application and plans) Ross A. Eamst, P. E., Director PERMIT FEE John W. Rants, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: (206) 433-0179 • Fax (206) 431 Project Name/Tenant: SEGALE RETAIL Description of work to be done (2) 1}" WATER METER" INSTALLED IN EXISTING METER BOX1i Will there be storage of flammable /combustible hazardous material in the building? ❑ yes IN no Attach list of materials and stora • e location on se •arate 8 1/2 X 11 • a • er indicatin • • uantities & Material Safet Data Sheets Value of Construction: N/A Site Address: 300 ANDOVER PARK WEST, TUKWILA, WA City State/Zip: 98188 Tax Parcel Numbe 2 Property Owner: LA PIANTA LIMITED PARTNERSHIP Address: P.O. BOX 88050 Phone: (206)575 -2000 Street Address: P.O. BOX 88050, TUKWILA, WA 98138 City State/Zip: Fax #: (206)575 -1837 Contact Person: MR. DANA WARREN 0 Sewer 0 Metro 0 Standby Phone: (206)575 -2000 Street Address P.O. BOX 88050, TUKWILA, WA 98138 City State /Zip: Fax 575 -1837 Contractor: N/A Phone: Street Address: City State/Zip: Fax #: RECEIVED Architect: N/A Phone: SEP 0 9 1996 Street Address: City State /Zip: Fax #: TUKWILA f UOLIC won :<€ Engineer: N/A Phone: Street Address: City State /Zip: Fax #: MISCELLANEOUSPERMIT REVIEW AND APPROVAL REQUESTED: (TO BE FILLED OUT BY APPLICANT) Description of work to be done (2) 1}" WATER METER" INSTALLED IN EXISTING METER BOX1i Will there be storage of flammable /combustible hazardous material in the building? ❑ yes IN no Attach list of materials and stora • e location on se •arate 8 1/2 X 11 • a • er indicatin • • uantities & Material Safet Data Sheets ■ Above Ground Tanks ■ Antennas /Satellite Dishes ■ Bulkhead/Docks ■ Commercial Reroof ❑ Demolition ❑ Fence ❑ Mechanical ❑ Manufactured Housing - Replacement only ❑ Parking Lots ❑ Retaining Walls ❑ Temporary Pedestrian Protection/Exit Systems ❑ Temporary Facilities ❑ Tree Cutting MONTHLY SERVICE BILLINGS TO: Name: LA PIANTA LIMITED PARTNERSHIP Phone: (206) 575 -2000 Address: P.O. BOX 88050 City /State /Zip: TUKWILA, WA 98138 0 Water 0 Sewer 0 Metro 0 Standby CITY OF "1KWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Miscellaneous Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST .FOR .MISCELLANEOUS PUBLIC WORKS PERMITS` ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering: 0 Cut cubic yards 0 Fill cubic yards 0 sq. ft.grading/clearing ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 1 " Size(s): 0 Deduct 0 Water Only ❑ Channelization/Striping ❑ Flood Control Zone ❑ Landscape Irrigation ❑ Storm Drainage ® Water Meter /Exempt # ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous ❑ Moving Oversized Load/Hauling WATER METER DEPOSIT /REFUND BILLING: Name: SAME Address: Phone: City /State /Zip: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: Wit' 41 MISCPMT.DOC 7/11/96 Date application expires: MRic4i �J>> lApplication taken by: (initials) , IVV� v BUILDING OWNER OR AUTH RIZED AGENT: SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2 :1 Signature: pa �J�a� ® i ❑ Date: ,91 . i w I�(a fe 4 Print name: vAHA ,`y\ '� 't iyi ❑ Phone:5 7 - �ZQ . , Fax # : 6 - 75 -, i 37 Address: ac /rc l .. u-f'k City / WW'f�c ip: — __ e ❑ SUBMIT APPLICATION AND REQUIRED CHECKLISTS FOR Above Ground Tanks/Water Tanks - Supported directly upon grade exceeding 5,000 gallons and a ratio of height to diameter or width which exceeds 2 :1 PERMIT REVIEW Submit checklist No: M -9 ❑ Antennas /Satellite Dishes Submit checklist No: M -1 ❑ Awnings /Canopies - No signage Commercial Tenant Improvement Permit ❑ Bulkhead/Dock Submit checklist No: M -10 ❑ Commercial Reroof Submit checklist No: M -6 ❑ Demolition Submit checklist No: M -3, M -3a ❑ Fences - Over 6 feet in Height Submit checklist No: M -9 ❑ Land Altering/Grading/Preloads Submit checklist No: M -2 ❑ Loading Docks Commercial Tenant Improvement Permit. Submit checklist No: H -17 ❑ Mechanical (Residential & Commercial) Submit checklist No. M -8, Residential only - H -6, H -16 0 Miscellaneous Public Works Permits Submit checklist No: H -9 ❑ Manufactured Housing (RED INSIGNIA ONLY) Submit checklist . No: M -5 ❑ Moving Oversized Load/Hauling Submit checklist No: M -5 1 ❑ Parking Lots Submit checklist No: M -4 ❑ Residential Reroof - Exempt with following exception: If roof structure to be repaired or replaced Residential Building Permit Submit checklist No: M -6 ❑ Retaining Walls - Over 4 feet in height Submit checklist No: M =1 ❑ Temporary Facilities Submit checklist No: M -7 ❑ Temporary Pedestrian Protection/Exit Systems Submit checklist No: M -4 ❑ Tree Cutting Submit checklist No: M -2 ALL MISCELLANEOUS PE ' APPLICATIONS MUST BE SUBM ED WITH THE FOLLOWING: ➢. * ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED ➢ ARCHITECTURAL DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED ARCHITECT ➢ STRUCTURAL CALCULATIONS AND DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED STRUCTURAL ENGINEER ➢ CIVIVSITE PLAN DRAWINGS REQUIRE STAMP BY WASHINGTON LICENSED CIVIL ENGINEER (P.E.) ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If not available at the time of application, a copy of this license will be required before the permit is issued, unless the homeowner will be the builder OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. MISCPMT.DOC 7/11/96 RECEIVED CITY OF TUKWILA SEP 0 9 1996 PERMIT CENTER RE SEP « 91996 TUKWILA PUBLIC WORK -€. J Envelope Requirements (enter values as applicable) Fully heated/cooled.space Minimum Insulation R- values Roofs Over Attic Glazing Area Calculation Note: Below grade walls may be included in t h e Gross Exte Wall pa N they are insulated to the level required for or opaque e walls. — Ail Other Roofs % Glazing Z' Opaque Walls � 7 ( l Below Grade Walls Applicant Phone: Floors Over Unconditioned Space -- Slabs -on -Grade –"' Radiant Floors — Maximum U- factors Opaque Doors d. &c Vertical Glazing 0.9° Overhead Glazing - f Maximum SHGC (or SC) VerticaUOverhead Glazing 1 (.00 Space Heat Type ❑ Electric resistance Ls, All other (see over for definitions) Date 4, lZg (a9::. Glazing Area Calculation Note: Below grade walls may be included in t h e Gross Exte Wall pa N they are insulated to the level required for or opaque e walls. Total Glazing Area (rough opening) (vertical 8 overhd) Gross Exterior divided by Wail Area times 100 equals % Glazing J � - j� 0 • _ 41 1 _ ( .41.2— X X 100 — � 7 Concrete/Masonry Option El Check here if using this option and if project meets all requirements for the ConcreteMasonry Option. See Decision Flowchart (over) for qualifications. Enter requirements for each qualifying assembly in the table below. Project Info Project Address Segale Retail Center Date 4, lZg (a9::. 300 Andover Park West #600 ForBuildin Department Use Tukwila, WA. Applicant Name: The Old Navy Store Applicant Address: 900 Cherry Ave., San Bruno, CA. Applicant Phone: Envelope Summary Climate Zone 1 ENV -SUM 1994 Washin ' . State Nonresidential Ener 1994 Washington State Nonres denial Energy Code Compliance Forms Semi- heated space' Minimum Insulation R- values Roofs Over Semi - Heated Spaces' 'Refer to Section 1310 for qualifications and requirements 3om a fiance Form Apnl. 1994 Project Description ❑ New Building ❑ Addition Alteration ❑ Change of Use Compliance Option ti(Prescriptive ❑ Component Performance (See Decision Flowchart (over) for qualifications) ❑ ENVSTD ❑ Systems Analysis Opaque Concrete/Masonry Wall Requirements Insulation on interior - maximum U- factor is 0.19 Insulation on exterior or integral - maximum U- factor is 0.25 If project qualifies for Concrete/Masonry Option, list walls with HC 2 9.0 BtuIR°•'F below (other walls must meet Opaque Wall requirements). Use descriptions and values from Table 20-5b in the Code. Wall Description (including insulation R -value 8 position) U- factor RECEIVED CITY OF TUKWI Illl fl 1 iqq PE ) RMIT CENTER Notes: vebo.r f fors (A+l 17_, f V(oQ Pf_4e4 T (A) (`.7c,ef. G (I6 AREA 7- ?i -t D t7,-- 7 0- f ��- V l � _ r l All Insulation installed? Opaque Walls Masonry walls (int) Masonry walls (other) R -11 U -0.19 U -0.25 Below grade walls (text) R -10 Below grade walls (othr) R -11 Roofs over attics R•30 lAll other roofs R -21 Floors over uncond.sp. R -19 Stabs -on -grade R -10 Radiant floors R -10 Opaque doors U -0.60 Glazing Criteria Met! Glazing Vert OH SHGC Area % U U SHGC 00.15% 0.90 1.45 1.00 15-20% 0.75 1.40 1.00 20-30% 0.60 1.30 0.65 30-40% 0.50 1.25 0.45 All Insulation Installed? Opaque Walls R -11 Below grade walls (eat) R -10 Below grade walls (othr) R -11 Roofs over attics R -30 All other roofs R -21 Floors over uncond.sp. R -19 Slabs -on -grade • R -10 Radiant floors R•10 Opaque doors 1.1-0.60 Glazing Criteria Met? Gluing Vert. 011 Area % U U SHGC 00.15% 0.90 1.45 1.00 15-20% 0.75 1.40 1.00 20-30% 0.60 1.30 0.65 30.40% 0.50 1.25 0.45 All Insulation Installed? Opaque Walls R -19 Masonry walls (int) U -0.19 Masonry walls (other) U -0.25 Below grade walls (ex!) R -10 Below grade walls (othr) R -19 Roofs over attics R -36 All other roofs R -30 Floors aver uncond. R -30 Slabs -on -grade R•10 Radiant floors R -10 Opaque doors U -0.60 Glazing Criteria Met? Glazing Vert OH Area % U U • SHGC 00.20% 0.40 0.80 1.00 All Insulation Installed? Opaque Walla R -19 Below grade *sits (ext) R -10 Below grade walls (otr) R -19 Roofs over attcs R -38 All other roofs R -30 Floors over uncond. R•30 Slabs-on-grade R -10 Radiant floors R -10 Opaque doors U -0.60 Glazing Criteria Mat) Gluing Vert OH Area % U U SHGC 00.20% 0.40 0.80 1.00 Envelope Summary Jack) Climate Zo ENV -SUM 1994 Washington State Nonresrdenbal Energy Code Comp fence Forms Decision Flowchart for Prescriptive Option Use this flowchart to determine If project qualifies for the optional Prescriptive Option. If not, either the Component Performance or Systems Analysis Options must be used. 1302 Space Heat Type: For the purpose of determining building envelope requtrementa, the following two categories comprise all space heating types: Other. All other space heating systems Including gas, solid fuel, oil, and propane space heating systems and those systems listed in the exception to electric resistance. (continued at right) \ ,� / .. �' All / Masonry N <- walls R -11 >- 4 Criteria OK ? ulab > Ninson?.' N. no (below) /` yes \ / Yes i'i40%\ '•('\ mg7i Yes T no 1994 Washin on State Nonresidential Ener Code Com a liance Form yes n o i no L ) r 1 Electric Resistance no N. Heat? . .' yes Prescnptrve Path Allowed Component Performance or Systems Analysis Required Electric Resistance: Space heating systems which use electric resistance elements as the pnmary heating system including baseboard. radiant, and forced air um) when the total electric resistance heat capacity exceeds 1.0 Wfle 01 the gross conditioned floor ens. Exception: Heat pumps and terminal electric resistance heating in vanable au volume distribution systems. e - <20% Yes Gazing?/ o T no Ns M asonry \ (Nall Criteria OK Yes \ (below) Ap 7 }4 walls R-19 ) no ‘insulator ? / yes no lazing?/ Concrete/Masonry Option* Assembly Description Wall Heat Capacity (HC) Assy.Tag NC** Area (sf) Totals Area weighted HC: divide total of (HC x area) by Total Area HC x Area no Apnl. 1994 *If the area weighted heat capacity (HC) of the total above grade wall is a minimum of 9.0, the Concrete Masonry Option may be used. For framed walls, assume HC =1.0 unless calculations are provided; for all other walls, use Section 2009. Stiv lst'&16��tzv:!H'awa'a.:a? „F tks x<aa�+ r�gy ' * J �itkS :d 'S•T: h MONTGOMERY & ERTS Consulting Engin s 11090 San Pablo Avenue EL CERRITO, CALIFORNIA 94530 (510) 232.1541 fax (510) 232 -0865 PRODUCT 2O41($m Is Shots) 2D5.1 (Pandadi /Rend /. Ina, crown, wa 0I4/l. to No PHONE TOLL FREE I.OW 225.6980 °O. it. `' v"o'sramSki.°mn.fi':nt,. [fc'Im::°i tueg iolteF. DIES /I:hmstf! L' tVT9p 'Y,.. �.RC�.�.,� tlw!;. JOB 0 7 .4 5 19 SHEET NO .441 OF CALCULATED BY Ce's.,Vr DATE CHECKED BY G.W DATE SCALE ��s r�Flw Rte -: A-r FF-tistr TrK E.Pta(44 Prg P t c6x(5 4- zc6,x 4-e-f-czh 3 frtgl * 74, tA 6 14 1, (•t ((r2.1x, 76L4NC1 = f q� Building Permit Plans Checklist ENV -CHK 1994 Washington Slate Energy Code Compliance Forms Apnl. 1994 Project Address 300 Andover Park West, 11600 Date The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Nonresidential Energy Code. Applicability (circle one) Code Section Component Information Required Location on Plans) I Building Department • Notes GENERAL REQUIREMENTSjSections 1301 -1314) 1301 Scope Unconditioned spaces identified on plans if allowed 1302 Space heat type yes no n.a. Electric resistance . es no n.a. Other Indicate on •tans that electric resistance heat is not allowed yes no n.a. 1310.2 Semi- heated spaces Semi- heated spaces identified on plans if allowed 1311 Insulation yes no n.a. 1311.1 Insul. installation Indicate densities and clearances yes no n.a. 1311.2 Roof /ceiling insul. Indicate R -value on roof sections for attics and other roofs; Indicate clearances for attic insulation; Indicate baffles if eave vents installed; Indicate face stapling of faced batts • yes no n.a. 1311.3 Wall insulation Indicate R -value on wall sections; Indicate face stapling of faced batts; Indicate above grade exterior insulation is protected; Indicate loose -fill core insulation for masonry walls as necess; Indicate heat capacity of masonry walls if masonry option is used or if credit taken in ENVSTD; yes no n.a. 1311.4 Floor insulation Indicate R -value on floor sections; Indicate substantial contact with surface; Indicate supports not more than 24" o.c.; Indicate that insulation does not block airflow through foundation vents yes no n.a. 1311.5 Slab -on -grade floor Indicate R -value on wall section or foundation detail; Indicate slab insulation extends down vertically 24" from top; Indicate above grade exterior insulation is protected yes no n.a. 1311.6 Radiant floor Indicate R -value on wall section or foundation detail; Indicate slab insulation extends down vertically 36" from the top; Indicate above grade exterior insulation is protected; Indicate insulation also under entire slab where req'd. by Official yes no n.a. 1312 Glazing and doors Provide calculation of glazing area (including both vertical vertical and overhead) as percent of gross wall area yes no n.a. 1312.1 U- factors Indicate glazing and door U- factors on glazing and door schedule (provide area - weighted calculations as necessary); Indicate If values are NFRC or default, if values are default then specify frame type, glazing layers, gapwidth, low-e • coatings, gas fillings yes no n.a. 1312.2 SHGC 8 SC Indicate glazing solar heat gain coefficient or shading coefficient on glazing schedule (provide area - weighted calculations as necessary) 1313 Moisture control yes no n.a. 1313.1 Vapor retarders Indicate vapor retarders on warm side yes no n.a. 1313.2 Roof /ceiling vap.ret. Indicate vapor retarder on roof section; Indicate vap. retard. with sealed seams for non -wood struc. yes no n.a. 1313.3 Wall vapor retarder Indicate vapor retarder on wall section yes no n.a. 1313.4 Floor vapor retarder Indicate vapor retarder on floor section es no n.a. 1313.5 Crawl s •ace va•. ref. Indicate six mil black • •l eth ene overla• • - • 12" on •round 1314 Air leakage yes no n.a. es no n.a. 1314.1 Bldg. envel. sealing 1314.2 Glazin• /door sealin• Indicate sealing, caulking, gasketing, and weatherstripping Indicate weatherstji. .j,. _ es no n.a. 1314.3 Assemb. as ducts Indicate sealin•, caulkin• and •asketin• PRESCRIPTIVE/COMPONENT PERFORMANCE (Sections 1320 -23 or 1330 -34) yes no Envelope Sum. Form Completed and attached. Provide component performance worksheet if necessary Provide ENVSTD screen 1 out•ut if necessa 1994 Washing State Nonresidential Energy Cod . 'ompliance Form no is circled for any question, provide explanation: 1994 Washing± ^n State Nonresidential Energy CodP Compliance Form Building Permit Plat s Checklist 1994 Washington State Energy Coda Compliance Forms ENV -CHK Apnl, 1994 Envelope - General Requirements 1311 Insulation 1311.1 installation Requirements: Ail insulation materials shall be installed according to the manufacturer's instructions to achieve proper densities, maintain clearances, and maintain uniform R- values. To the maximum extent possible, insulation shall extend over the full component area to the intended R- value. 1311.2 Roof /Ceiling Insulation: Open -blown or poured loose -fill insulation may be used in attic spaces where the slope of the ceiling is not more than 3/12 and there is at least thirty Inches of clear distance from the top of the bottom chord of the truss or ceiling joist to the underside of the sheathing at the roof ridge. When eave vents are installed, baffling of the vent openings shall be provided so as to deflect the incoming air above the surface of the insulation. Where lighting fixtures are recessed into a suspended or exposed grid .ceding, the roof /ceiling assembly shall be insulated in a location other than directly on the suspended ceiling. Exception: Type IC rated recessed lighting fixtures. Where installed in wood framing, faced bait insulation shall be face stapled. 1311.3 Wall Insulation: Exterior wall cavities isolated during framing shall be fully insulated to the levels of the surrounding walls. When installed in wood framing, faced batt insulation shall be face stapled. Above grade exterior insulation shall be protected. 1311.4 Floor Insulation: Floor insulation shall be installed in a permanent manner in substantial contact with the surface being insulated. Insulation supports shall be installed so spacing is not more than twenty- four inches on center. Installed insulation shall not block the airflow through foundation vents. 1311.6 Slab -On -Grade Floor: Slab -on -grade insulation installed inside the foundation wat shall extend downward from the top of the slab a minimum distance of twenty-four inches or to the top of the footing, whichever is Tess. Insulation installed outside the foundation shall extend downward a minimum of twenty-four inches or to the frostline, whichever is greater. Above grade insulation shall be protected. Exception: For monolithic slabs, the insulation shall extend downward from the top of the slab to the bottom of the footing. 1311.6 Radiant Floors (on or below grade): Slab -on -grade insulation shall extend downward from the top of the slab a minimum distance of thirty -six inches or downward to the top of the footing and hor for an aggregate of not less than thirty -six inches. If required by the building official where soil conditions warrant such insulation, the entire area of a radiant floor shall be thermally isolated from the soil. Where a soil gas control system is provided below the radiant floor, which results in increased convective flow below the radiant floor, the radiant floor shall be thermally isolated from the sub -floor gravel layer. 1312 Glazing and Doors 1312.1 Standard Procedure for Determination of Glazing and Door U- Factors: U- factors for glazing and doors shall be determined. certified and labeled in accordance with Standard RS -31 by a certified independent agency licensed by the National Fenestration Rating Council (NFRC). Compliance shall be based on Model Size AA or BB. Product samples used for U- factor determinations shall be production line units or representative of units as purchased by the consumer or contractor. Unlabeled glazing and doors shall be assigned the default U- ?actor in Section 2006. 1312.2 Solar Heat Gain Coefficient and Shading Coefficient: Solar Heat Gain Coefficient (SHGC), shall be determined, certified and labeled in accordance with the National Fenestration Rating Council (NFRC) Standard by a certified; independent agency, licensed by the NFRC. Exception: Shading coefficients (SC) shall be an acceptable alternate for compliance with solar heat gain coefficient requirements. Shading coefficients for glazing shall be taken from Chapter 27 of Standard RS -27 or from the manufacturer's test data. 1313 Moisture Control 1313.1 Vapor Retarders: Vapor retarders shall be installed on the warm side (in winter) of insulation as required by this section. Exception: Vapor retarder installed with not more than 1/3 of the nominal R -value between it and the conditioned space. 1313.2 Root /Ceiling Assemblies: Roof /ceiling assembles where the ventilation space above the insulation is less than an average of twelve inches shall be provided with a vapor retarder. Roof/ceiling assemblies without a vented airspace, where neither the roof deck nor the roof structure are made of wood, shall provide a continuous vapor retarder with taped seams. Exception: Vapor retarders need not be provided where all of the Insulation is installed between the roof membrane and the structural roof deck. 1313.3 Walls: Walls separating conditioned space from unconditioned space shall be provided with a vapor retarder. 1313.4 Floors: Floors separating conditioned space from unconditioned space shall be provided with a vapor retarder. 1313.6 Crawl Spaces: A ground cover of slot mil (0.006 inch thick) black polyethylene or approved equal shall be laid over the ground within crawl spaces. The ground cover shall be overlapped twelve inches minimum at the joints and shall extend to the foundation wall. Exception: The ground cover may be omitted in crawl spaces if the crawl space has a concrete slab floor with a minimum thickness of three and one -half inches. 1314 Air Leakage 1314.1 Building Envelope: The requirements of this section shall apply to building elements separating conditioned from unconditioned spaces. Exterior joints around windows and door frames, openings between walls and foundation, between wails and roof and wall panels: openings at penetrations of utility services through walls, floors, and roofs; and ail other openings in the building envelope shall be sealed, caulked, gasketed, or weatherstripped to limit air leakage. 1314.2 Glazing and Doors: Doors and operable glazing separating conditioned from unconditioned space shall be weatherstripped. Fixed windows shall be tight fitting with glass retained by stops with sealant or caulking all around. Exception: Openings that are required to be fire resistant. 1314.3 Building Assemblies Used as Ducts or Plenums: Budding assemblies used as ducts or plenums shall be sealed. caulked, and gasketed to limit as leakage. Project Address 300 Andover Park West #600 Date Space Heat Type ❑ Electric resistance ❑ All other For Building Department Use Glazing Area as % gross exterior wall area % Concrete/Masonry Option ❑ Yes ❑ No Notes: If glazing area exceeds maximum allowed in Table, then calculate adjusted areas on back (over). If Concrete/Masonry Option is used, Target U- factors, SHGC and Glazing % will be different than shown below. Refer to Table 13 -1 for correct values. Building Component List components by assembly ID & page # Proposed UA U- factor x Area (A) = UA (U x A) Target UA U- factor x Area (A) = UA (U x A) 6ulzeID to 14aA U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: Glazing % Electric Resist.. Other Heating . 0.15% 0.40. 0.90'. >15 -20% 0.40:. :. : 0.75 t allowed : : ` ' . 0.60: 2030% ' rid >2t1-3 >30 -40% not. allowed •• .:. .• 0.50 (see Table 13-1 for ConclMasonry values) 6ulzelo peaymn0 U= Plan ID: U= Plan ID: U= Plan ID: - U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: Glazing.% Electric Resist. . Other Heating ' 0.15% . 0.80 - . :1.45 '. • >15 -20% 0.80. ' .1.40 >20.30% not allowed 1.30 >30 -40% . not allowed • 1.25.; . (see Table 13-1 for Conc/Masonry values) Opaque Doors U= Plan ID: U= Plan ID: U= Plan ID: :Electric Resist . . Other Heating • 0.60 0.60 JaA0 s)ooa _ R= Plan ID: R= Plan ID: R= ' Plan ID: Electric Resist. Other Healing 0.031 0.036 SJOOd JaWlo R= Plan ID: R= Plan ID: R= Plan ID: Electric Resist. Otter Heating 0.034 0.050 • Opaque Walls' R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: Electric Resist. .Other Heating Ordnary • 0.062 0.14 Metal stud 0.11 • 0.14 Conc(int) ' 0.19 • '.'0.19' Conc(oth). • '0.25 • .0.25 Below (Grade Walls R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: 'Electric Resist. . Other Heating 'Ordinary 0.062 0.14 Metal stud '0.11 ' • 0.14 I Floors Over I Uncond. Sp. - R = Plan ID: R= Plan ID: • R= Plan ID: R= Plan ID: - • Electric Resist.. Other Heating 0.029 0.056 I apei6 1 R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: Electric Resist. Other Heating ' F =0.54 F =0.54 (see Table 13.1 for radiant floor.velues) For CMU walls, indicate core insulation material. Totals! For compliance: Totals! • Envelope UA Calculations Climate Zone 1 ENV -UA 1994 Washi :n State Nonresidential Ener C e? ' , Com a liance Form 1994 Washington State Nonresidential Energy Code Compliance Forms April, 1994 1) Proposed Total Area shall equal Target Total Area, and 2) Proposed Total UA shall not exceed Target Total UA. 1: OG= 2: OG= 3: VG= 4: 5: 6: Vertical Glazing List components by assembly ID & page # Proposed SHGC SHGC' x Area (A) = SHGC x A Target SHGC SHGC x Area (A) = SHGC x A 6uRe10 leollnA Plan ID: Plan ID: Plan ID: Plan ID: Plan ID: Plan ID: Glazing % Electric Resist. Other Heating 0-20% 1.00. 1.00' >20-30% not allowed • 0.65 >30-40% not arrived 0.45 (see Table 13.1 for Cone/Masonry values) 'Note: Manufacturer's SC may be used In lieu of SHGC. For compliance: Totals Totals' Overhead Glazing List components by assembly ID & page # Proposed SHGC SHGC' x Area (A) = SHGC x A Target SHGC SHGC x Area (A) = SHGC x A Overhead Glazing Plan ID: Plan ID: Plan ID: Plan ID: Plan ID: Plan ID: Glazing % Electric Resist. Other Heating 0.20% 1.00 1.00 >20 -30% not allowed 0.65 >30 -40% not allowed 0.45 (see Table 13-1 for Conc/Masonry values) 'Note: Manufacturer's SC may be used in lieu of SHGC. Totals For compliance: Totals Envelope SHGC C. lations Climate Zone ENV -SHGC 1994 Washington State Nonresidential Energy Code Compliance Forms Target Area Adjustment Calculations If the total amount of glazing area as a % of gross exterior wall area (calculated on ENV -SUM) exceeds the maximum allowed in Table 13-1, then this calculation must be done. Use the resulting areas in the Target UA and SHGC calculations above. Glazing Area Opaque Area Gross Exterior Wall Area 1x1 opal = 100 =17: 17: Roofs over Attics Other Roofs Walls' 1994 Washin ton State Nonresidential Ener Code Com • 'lance Form 1) Proposed total area shall equal Target Total Area, and 2) Proposed Total SHGC shall not exceed Target Total SHGC. 1) Proposed total area shall equal Target Total Area, and 2) Proposed Total SHGC shall not exceed Target Total SHGC. Proposed Areas: Numbered values are used in calculations below. Roofs over Attics Other Roofs Walls Target OG Area In Roofs over Attics Max OG Remaining Max Glazing Area (Table 13 -1) 1: II lesser (circle) 7: • 4: 5: Proposed Opaque Area 1 6: 18: 1 Proposed Opaque Area Proposed OG Area + 1: 2: Proposed VG Area 1 3: Target OG Area in Other Roofs Total Ta get OG Area (sum #10 + 1111) Maximum Target Glazing Area 2: II lesser (circle) 8: Target OG Area W 10: 11: 12: Target VG Area Target VG Area 1 9: Target Opaque Area 13: 14: Target Opaque Area 115 : + — 1 9 : = Note: If there is more than one type of wall, the Target VG Area may be distributed among them, and separate Target Opaque Areas found. Target values 9, 12,13,14 & 15 (shaded boxes) are used in the applicable Target UA calculations on the front. Target values 9 & 12 are also used in the applicable Target SHGC calculations above. April, 1994 Note: OG = overhead glazing VG = vertical glazing For Target OG's, circle and use the lesser values both here and below. Fan Equipment Schedule - Equip. ID , Brand Name' Model No.' CFM SP' HP /BHP Flow Control Location of Service CE bt-cK .----(7" VF a 75 (W . , . , - 7121 PS- col, 6i(`z f-{ 44k r? (ZS 0.575" 7C liJ Yiig- ST-64> 'jar t4 g f1 i• I $o,00O ferifrod t aZ- 9 0 e '� ' f e t& Ec-r(c r. r' Me- _,rla •■ r . _ri 414(O -f imcAtle, tiff -F-P 19-- • Zo1.c.W 1 o — • — — -- Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Total CFM OSA CFM Econo SEER ott IPLV Location ,rk,4" CfrFF I 4 'f•LP01 2.s r-i y eio Di? 6.0/7 J (. b 97 437-x, .RA65 ' "(ft 4%ri (41,6t400 4-000 (, 00 I $o,00O ferifrod t aZ- 9 0 e '� ' f e t& Ec-r(c r. r' Me- _,rla •■ r . _ri 414(O -f imcAtle, tiff -F-P 19-- • Zo1.c.W 1 o — • — — -- _ Heatin; E. ui I ment Schedule Equip. ID Brand Name' Model No.' Capacity Total CFM OSA cfm Econo Input Btuh Output Btuh Efficiency` , ,. 41/41M111 , ; ND a12— , : 4 bob (orbt) ; o-0 '' 600 437-x, .RA65 ' "(ft 4%ri (41,6t400 4-000 (, 00 I $o,00O ferifrod t aZ- 9 0 e '� ' f e t& Ec-r(c r. r' Me- _,rla •■ r . _ri 414(O -f imcAtle, tiff -F-P 19-- • Zo1.c.W 1 o — • — — -- _ Project Info Project Address 300 Andover Park West #600 Date 2_0 c3 - tvKW ILA For Building epart ent Use f Applicant Name: o� t l C- , crrp r/Y�� Applicant Address: g i+ 1J,; ,r� p e / ��� ��/�" '' ow) e ..JJ C/risi1�1�7 rJ r{/ Applicant Phone: 1994 Washin/" -t State Nonresidential Ener Co. Com•liance Form Mechanical Summary • MECH -SUM 1994 Washington State Nonresidential Energy Code Compliance Forms Apnl. 1994 Project Description Briefly describe mechanical system type and features. trJSTALL- (-- { Tf7* PovF'•i 64ste. tc-rgfe v�r� over_ r (44 "4r- q4GP-- Compliance Option Simple System ❑ Complex System ❑ Systems Analysis (See Decision Flowchart (over) for qualifications) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. 2 As tested according to Table 14-1, 14-2 or 14-3. 3 If required. ` COP, HSPF, Combustion Efficiency, or AFUE, as applicable. s Flow control types: VAV, constant volume, or variable speed. C\ System Description See Section 1421 for full description of Simple System qualifications. If Heating/Cooling or Cooing Only: la vol? ❑ Split system? ZrAlr cooled? Packaged sys? ❑ <54,000 Btuh? Economizer included? If Heating Ony ❑ <5000 cfm? ❑ <70% <70,5 outside air? Mechanical Summary (back) MECH -SUM 1994 Weshinpton Sr. et Nonressdonlal Energy Code Compliance Forms Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Anaysis Options must be used. System Type <5000 cfm <70% OA eating /Cooling or Cooling Only ackage stem? Split stem? 54,000 Btu r 1900 cfm 54,000 Btu r 1900 cfm onstan olume Ir Cooled . Reference Sec. 1430 Heating On no no Complex Systems L V 1994 Washington State Nonresidential Energy Code Compliance Form yes yes Reference ■ Sec. 1423 4 Simple System l Allowed Reference Sec. 1420 yes yes no Use Complex - System Apnl. 1994 Refer to MECH -COMP Mechanical Complex Systems for assistance In determining which Complex Systems requirements are applicable to this project. Mechanical Permit Plans Checklist MECH -CHK 1994 Washington Stale Energy Code Compliance Forms Apnt, 1994 Project Address 300 Andover Park West #600 (Date 6,42 The following Information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability Code (circle one) Section Component Information Required Location on Plans Building Department Notes HVAC RE UIREM S JSections 1101-1424) 1411 Eqpmt performance s no . 1411.4 Pkg. elec. htg.d cig. Minimum efficiency _ List heat pumps on schedule Equipment schedule with type. capacity, efficiency Pt (,} no n.a. 1411.1 1412 HVAC controls no n.e. 1412.1 Temperature zones Indicate locations on plans M2,1 no rl,a. 1412.2 Deadband control Indicate 5 degree deadband minimum MP1,Q no .a 1412.3 Humidity control Indicate humidistat -- no n.e. 1412.4 g3 Automatic setback Indicate thermostat with night setback and 7 different day types Meta no n.e. 1412.4.1 Dampers Indicate damper location and automatic controls My, t yes no 1412.5 Heat pump control Indicate microprocessor on thermostat schedule — , no n. 1412.6 Combustion htg. Indicate modulating or staged control — 117 no n,a. 1412.7 Balancing Indicate balancing features on plans (12-,} ' s no n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans r t-O ('ice no n.a. 1423 Economizers Equipment schedule M I. I 1413 Air economizers i - no n.a. 1413.1 Operation Indicate 100% capability on schedule ('If..! 6'a, no n.a. 1413.2 Control Indicate controls able to evaluate outside air MP!. b no n.a. 1413.3 Integrated operation Indicate capability for partial cooling MJ_ f 1414 Ducting systems no n.a. 1414.1 Duct sealing Indicate sealing necessary MPtr•0 no n.a. 1414.2 Duct insulation Indicate R -value of insulation on duct -4 es no 1415.1 Piping insulation Indicate R -value of Insulation on piping -MPI —� no n.a. 1424 Separate air sys. Indicate separate systems otulans 141,024 no Mech. Sum. Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer A �t SERVICE NATER REAM AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. yes no .a 1441 Elec. water heater Indicate R -10 insulation under tank i yes no 1442 Shut -off controls Indicate automatic shut -off — 1450 Heated pools —. yes no .a 1452 Pool water heaters Indicate not electric resistance -- yes no .a 1453 Pool heater controls Indicate switch and 65 degree control yes no 1454 Pool covers Indicate vapor retardant cover — , Yes no ,a 1454 Pools 90+ degrees Indicate R -12 pool cover —' i: :: S. iiEY;;!j'$iC'�`.kT.�.`,r:s'.':a 1994 Washing State Nonresidential Energy Codf ompliance Form no circled f any question, provide explanation: .C:�i�lr�goa'.::.r. F.;: s�^ , ^.rmsz'�• >, rorm �.1 1994 Washinconn State Nonresidential Energy Cod^ Compliance, Form Mechanical Permit ans Checklist 1994 Washington State Energy Code Compliance Forms MECH -CHK April, 1994 Mechanical - General Requirements 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate .. zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut-Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off- hour controls. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open dampers. These dampers shall remain closed in normal operation until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. 1413.2 Control: Air economizers shall be controlled by a control system capable of determining if outside air can meet part or all of the building's cooling loads. 1413.3 Integrated Operation: Building Heating Energy: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Controls shall not preclude the economizer operation when mechanical cooling is required simultaneously. Exception: Economizers on individual, direct expansion, cooling systems with capacities not greater than 75,000 Btu/h may include controls that limit simultaneous operation of the economizer and mechanical cooling for the,purpose of preventing ice formation on cooling coils. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. 1414.2 Insulation: Ducts and plenums that are constructed as part of the building envelope shall meet the requirements of Chapter 13. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a space that serves that space only. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally Insulated in accordance with Table 14-6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shah be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1420 SIMPLE SYSTEMS (PACKAGED UNITARY EQUIPMENT) 1421 System Type: To qualify as a simple system, systems shall be one of the following: a. Air cooled, constant volume packaged equipment, which provide heating, cooling or both, and require only external connection to duct work and energy services. b. Air cooled, constant volume split systems, which provide heating, cooling or both, with cooling capacity of 54,000 Btu/h ...or less. c. Heating only systems which have a capacity of less than 5,000 cfm or which have a minimum outside air supply of less than 70 percent of the total air circulation. All other systems shall comply-with Sections 1430 through 1438. 1422 Controls: In addition to the control requirements in Section 1412, whore separate heating and cooling equipment serve the same temperature zone, thermostats shall be interlocked to prevent simultaneous heating and cooling. 1423 Economizers: Economizers meeting the requirements of Section 1413 shall be installed on packaged roof top tan - cooling units having a supply capacity of greater than 1,900 cfm or a total cooling capacity greater than 54,000 BtUTh. The total capacity of all units without economizers shall not exceed 240,000 Btu/h per building. 1424 Separate Air Distribution Systems: Zones with special process temperature requirements and/or humidity requirements shall be served by separate air distribution systems from those serving zones requiring only comfort conditions. Mechanical - Complex Systems Checklist MECH -COMP 1994 Washington State Energy Code Compliance Forms Apnl, 1994 Project Address 300 Andover Park Wggt #600 Date The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH -CHK checklist for additional system requirements). This information must be on the plans since this Is the official record of the permit. Having this information In separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability I (circle one) Code Section (Component Information Required Location on Plans Building. Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY yes no n.e. 1431.1 Field assem. sys. Provide calculations 1432 Controls yes no n.a. 1432.1 Setback 8 shut -off Indicate seprate systems or show isolation devices on plans 1432.2 Temp. reset control yes no n.a. 1432.2.1 Ak systems Indicate automatic reset no n.a. 1432.2.2 H . tunic s terns Indicate automatic reset yes no n,a. 1433 Economizers Indicate economizer on equipment schedule or provide calculations to justify exemption yes no n.a. 1434 Separate air sys. Indicate separate systems on plans yes no n.a. 1435 'Simul. htg. 8 clg. . Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified yes no n.a. 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations 1 yes no n.a. 1437 motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency Yes no n.a. 1438 4 Elec. Variable flow sys. Indicate variable flow on fan and pump schedules • • '� itkdx� Seale" 14324 Hot Water Supply Tempeature Rent Controls Requited No 1994 Washin State Nonresidential Energy Cot Form no is circled for any question, provide explanation: Decision Flowchart Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. Capacity of HW Heating System Otesta Thus 000.000 Btuh" Start Here Settee 1411.1 Equipment Pert. Shan Meet Tables 14-1 through 14.3 Field. s. Mumbled • ••,Eqr , , • No� • No • System Multiple Zona U Yes Seeds* 1431.1 Cakuiauau or Total On •site Energy input & Output Required Stales 1432.2.1 Supply Air Reset Controls Requited t (continued on back) n5'efibec.]+::rt az» c. �r. r. rc• ar , e•xt�..�c:t!��•�R:.ai��;..�.a� .�.�- �ne�ex<. 62) echanical - Comr.x Systems (back) S MECH-COMP 1991 Washington State Nonresidents( Energy Code Compliance Forms Seetlee1411.4 Must be Heat Pump 1411.5 Provide Microprocessor Heat Pump Controls 1994 Washin•ton State Nonresidential Ener• Code Corn liance Form 0 0 No (continued from front) /N Yes ce°1 s Yes ,/ Heat ing & \ pectic Heatin.'• CaPacilY C°4". N • 20,000 , N Packae? • Btri / \Ny./ Fuel \ •• riupply Air >•'.. Yes 5000 CFM \ Outside Air > 7014? V Done l I • .. / • Seetfic .... <.........., Efficiency '`..... No . ,. speed ' N included in Equipmer >-0.•< Motor in a % Performance . ' / \ Multi-speed / Retinal . System? i ' •7 \ ., .../. Yes Non-Electric Yes ..,,Capacity? No Stollen 1433 Air-Side Economizer Required ao• \ % • • Yes Yes Settles 1411.4 Modulating or Staged Combustion Controb Required Sedate 1434 50% Effective Heat Recovery System Required App lication Yes Yes pans or Pump' „V.ariainblevolvXows; 10 HP7 • • •`■ N No No 7 N Studio 1435 Fen Powered Y " vAv Terminal Unita System? ,• ■ Required N ,/ ..."..... .,. ...., • .„. \ i ..• Cooling .. Yea / Packaged N. No „ • Cooling • -.., No ,.., Total 1:114 -.. No Capacity> :-10.4, Rooftop "— Capacity > :,--4.: e > • ;.—..— '.,54,000 Otuh?./ - .• ' • , 84,000 Otuh?,.. • •' N. , 240 , 000 8tuh? ../• ...• 'N. ./ N.. " Yea NOT Settles 1435 Simultsneoue Heating k Cooling Prohibited Section 1437 Moton Must Meet Ef5ciencies Table 14-4 Apnl, 19134 Li • Jos No .... s9+' tatimuctraiu`vti 1 ENGIIERS- NORTHWESTNC. P.S. 6869 WOODLAWN AVE. N.E. - SUITE 205 - SEATTLE, WA 98115 (206)525 -7560 - FAX # (206) 522 -6698 { • 1„ L ' � DATE 6 - IS "9.6 SUBJECT SHEETCLO OF BY ft • Rs1110 t2.. JOB NAME ■?_0(1‘02At... citLcutAioNs ro - 61 I? 2 N 0 0YL_ ' LE'R I L I ,-�- 1\h(W I Lit K3 A514 ttJ rD fJ 6Q(k) If 530k(-`01 EXPIRES 11/12/ 4 14 I RECEIVED CITY OF TUKWILA JUL 011996 PERMIT CENTER Jos No. Joe NAME 7Ritl4 - IZ h Eve r,>t tL enp - alp N E� e S So A, LZ• a S ifYN� Pf4 > ^ ;2;) ta'A fl'Mit'i ,TAr.R.; Z = (%Z1X (3� — ( 73� (IY23 = I O,Y �C u�1 LL 60a) 0/ 2- 11/4)_ •96 / 10 1 ti ENG I ItT.ERS - NORTH WEST NC. P.S. • 6969 WOODLAWN AVE. N. E. - SUITE 205 - SEATTLE, WA 98115 - (206)525.7560 - FAX # (206) 527 -6698 DATE 6- •1 -q SUOJECT SHEET BY OF .{.S n., LOAD CASES IOMENT AND DEFLECTION RESULTS +inwarc - outward Case Pu (kips) Mu iin -k) Phi=Mn defi tin INTERACTION CuRVE DATA . ,7*PC ix :te 7xMnal x�� 124.2 L:,: 105.8 33.1 (GINEERS-NORTHWEST CONCRETE.JAMB DESIGN (version 3.01 169 Mcodlawn Ave NE . 1988 UBC 3attle,Wasnington 98115 09:20:44 06 -14 -1996 po 100 0MB DATA height (ft) width (in) thickness lin) ada thickness iin) r. ;actor parapet ht (ft) 29.67 48.00 7.25 0.00 1.00 0.00 PANDREL DATA thickness(in) offset lin. + outward) 7.25 0.00 PENINGS LEFT wioth (ft) height (ft) RIGHT widtn ifti height (ft) 12.0 10.0 0.0 0.0 ATERIAL DATA concrete (psi) rebar (psi) 3000 60000 gtia. WPoZ OADING DATA unfactored • - wind in (psf) :. 0,0 cur ' i- Q'� cillcittru ( seismic... zone G Press 1osf1: import fact: 1.00 ledger Wolf): 600 DL ipif): 360 ecc fin): 0.5 % lL.► /seismic: concentrated ion Lli )bs): 0 DL i )bsi: 10000 ecc (in): 0.0 % LL w /seismic: G concentric laza Wolf): 0 DL (PM: 0 % IL wiseise11c: L noriz loaa plf (+ inward): 0 dist above fioor(ft): 0.0 EBAR DATA Vertical - $5 a: 3.62 Horizontal min in / it 0,17 Allow aefitini (,amments Sheet of STRNDER RETAIL NEW DOOR 12;10 PNLS 50 s 52 1 5.1 77.8 56.29 -0,10 2.37 case c►. 2 6.1 - .: 56.29 -0.10 2.3 case ca 6.1 '7.8 56.25 -0.10 2.37 case ok 4 5.1 -11.0 60.15 -0.12 2.27 case of 5 8,1 -11.6 60.15 -0.12 2.37 case ok 5 7.1 - °.L 58.31 -0,10 2.31 case :f, 7 12.0 -20.2 63.00 -0.14 2.27 case used interaction clorve 11 .:UL - 1.2.111. inwarc NOTE it cases 1i. _ :, an:: _ the 21 .501 + 1.2wL outward • LL dse: is 112 of toe acc.iec LL 3) ,:DL + 1.43EQ 4i 1.0501 + 1.2SLL + 1.28W. inwarc 5) 1.OSD1 + 1,28LL . 1.28v. cutwarc 61 1.050L + 1.2SLL + i.4EQ 71 1.L10L + 1.7LL CDC 462. . nt. u1n• 1/2 1/2 112 • 5/8 5/E 518 3/4 3/4 3/4 ENGINEERS NN Confidential 3 211V070 w3 1 w4 1 w5 I .lateral design 24.2 V = 3231 Page 1 H ft = 29.67 F'c= 3000 h ft = 12 wind = 24.20 psf w1 ft = 5 siisaic 19.7 psf w2 ft = 10 y1= 1 w3 ft = 4.0 r= 10 w4 ft = 0.0 y2= 1 e5ft =0 H/150 = 2.37 u = 217.80 C = 2988.32 T = 2370.86 M = 23709 SRItd1 = 7.05 SUM = 12 A, ;F,it. r = 32.80 INPUT TS MOMENT OF INERTI 75.10 -4,1841 r5 MEIIST _ 23966 NFL. = 1.74 55.17 MISOLATE= 2309: ALLOWACLE DEFLECT 2.37 ?A?1 1 WIT:. STRONG BACK IS CK MAX '. = 2988.3 TABS SASE JERT 5" CLEAR PLATE W10 IUSPEC BOLTS p: 6in.T0 EDGE 11SPEC B•ZLTS F'CI:SI EMBED T allow RE8'11 ?L :hie:: '/ al REO'L 2 1/4 615 4.8E 9 0.204 1840 2.00 3 112 1000 2.99 3 0.204 1840 2.00 6 1080 2.77 i 0.204 1840 2,00 2 3/4 875 3.42 0.195 2875 2.00 r 1335 2.24 11 0.185 3125 2.00 7 1625 1.84 11 0.185 3125 2.00 3 1/4 1090 2.74 3.177 3E75 1.00 �4 4 A 4n'1C 1 314 4' T' 1. ,, 1i. 1..171 422J 8 2315 1.29 :2 0.177 4225 1.00 1D .J A.M.P,s NI C#thNILlq,,, t1mt ENG IF ERS— NORTH WESTC NC. :P. S. 6869 WOODLAWN AVE. N.E. - SUITE 205 - SEATTLE, WA 98115 - (206)525 -7560 -. FAX # (206) 522 -6698 Joe No. JOB NAME 5kftr.i 1) R ►rttL. I 'L ' DATE SUBJECT 6It? q•^ SHEET OF BY Loci c d Mcc t( AS SxowN or to . joisi J., Joys, 41 i u ) AyLC P c t C� N COQ 6 M2,(4) '2 rv, I ►J N, ' 630,3-0,\ O° ?u\-14S fioL IIIANfIt SolPG c AitouN( opeA104 . Extsi ‘joi3 it-ck& E xls i 504 Dear Sir: City of Tukwila Fire Department Review Control #B96 -0190 (512) Fire Department Thomas P. Keefe, Fire Chief July 24, 1996 Re: Old Navy Store - 300 Andover Park West, Suite #600 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area.. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA.10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 -4404 • Fax (206) 5754439 City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Page number 2 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) Maintain fire extinguisher coverage throughout. 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Obstructions, including storage, shall not be placed in the required width of an exit, except projections as permitted by the Building Code. Exits shall not be obstructed in any manner and shall remain free of any material or matter where its presence would obstruct or render the exit hazardous. (UFC 1203) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207.1- 1212.8) Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1013.3) When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 -4404 • Fax (206) 575.4439 City of Tukwila Fire Department Page number 3 The color and design of lettering, arrows and other symbols on exit signs shall be in high contrast with their background. Words on the sign shall be block letters 6 inches in height with a stroke of not less than 3/4 inch. (UBC 1013.2) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Exits shall be illuminated any time the building is occupied with light having an intensity of not less than 1 foot candle at floor level. Fixtures required for exit illumination shall be supplied from separate sources of power for Group I, Divisions 1.1 and 1.2 occupancies and for all other occupancies where the exiting system serves an occupant load of 100 or more. (UBC 1012.1, 1012.2) When two or more exits from a story are required and when two or more exits from a room or an area are required by U.B.C. Section 3303, exit signs shall be illuminated. (UBC 1013.3) The power supply for the exit pathway illumination shall normally be provided by the premise's wiring system. In the event of its failure, illumination shall be automatically provided from an emergency system. Emergency system shall be supplied from storage batteries or an on -site generator set and the system shall be installed in accordance with the requirements of the Electrical Code. (UBC 1012.2) John W Rants, Mayor Thomas P. Keefe, Fire Chief Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) Current supply to one of the lamps for exit signs shall be provided by the premises' wiring system. Power to the other lamp shall be from storage Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Thomas P. Keefe, Fine Chief Page number 4 batteries or an on -site generator set and the system shall be installed in accordance with the Electrical Code. (UBC 1013.4) 3. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1742) 5. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone; (206) 575 -4404 • Fax (206) 5754439 Page number 5 Yours truly, cc: TFD file ned City of Tukwila The Tukwila Fire Prevention Bureau Fire Department Thomas P. Keefe, Fire Chief 6. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575-4439 V.* �0i4 'Am�n1AT yHiC Win+ +rn+..wv.ratot. u.*attra Property service 6/28/96 James Furrate 1035 156th N.E. Bellevue, WA. Re : Old Navy Store Tukwila, WA. Dear Mr. Furrate, Gary Palmer Please find enclosed 3 sets of signed & sealed building plans for submission to plan check, Building Permit Application, Mechanical Permit Application, 3 sets of structural calculations, mechanical forms, a check in the amount of $609.21 for payment of plan check fees based on a BLDG. valuation of $110,000 and mech. valuation of $48,000, check in the amount of $300.00 for payment of your fee and a S.A.S.E. for return of any receipts and paper work from plan check submission. I checked plan review requirements for both electrical & plumbing and was told that no plan review is required, could you please verify that this is correct. I spoke with the Dept. of Labor & Industries @ 206 - 248 -6630 for electrical and the King County Health Dept., Eastgate Office @ 206 - 296 -9741 - Mike Bratcher. All the information I have, including the plan check fee amount was provided by Kelcie Perterson @ the Tukwila Building Dept. phone ¢/ 206 - 431 -3672. Thank you for all your help and if you have any questions, please feel free to call. JUL U 1 1996 PERMIT CENTER Post Office Box 23767 • Pleasant Hill • California 94523 • (510) 825 -2940 Gary Palmer RECEIVED CITY OF TUKWILA PLEASE DETACH AND SIGN CERTIFICATE BEFORE PLACING IN BILLFOLD siGtiATORe':•- ISSUED BY DEPA igreg. //40: vro • • TMENT OF LABOR AND INDUSTRIES • . • . RECE1" CITY OF ;LIIONILA AUG 0 7 C3 PERMIT CENTER F625-052-000 (3-92) • cc U i 1 , V W W W J �I a. 0 m o co cc a_ i ft I a i a I C) U C) v 0 U U C) 10 t7' v 25'- C C C C C CIC EXISTING WAREHOUSE BUILDING TRAFFIC LANE TRAFFIC LANE Q EXISTING LEFT TURN LANE 8 TRAFFIC LANE ATE C / / A/ xY / 4/ > / \ , /7 r • W/ , / i c2 --- o - n S LY .. 11 ' / J UST BLOCKING / /, ' • l :IST1NG WAREHOUSE BUILDING TRAFFIC LANE TRAFFIC LANE ' EXISTING LEFT TURN LANE P TRAFFIC LANE = E b 011 J if /THRUST BLOCKING I I CIClC�Cicic ClC 0 CAUTION: THE CONTRACTOR SHAD. EXCF.RSIZE EXTREME CARE To NOT DLS THE D L AND UTILITY SYS EMS INSTALLING iroR THIS BUILDING. EXISTING 8' WATERYAIN A DER I3LVD- TENANT A W /BOx • 1 -80 TAPPING EXTREME CARE TO GASINE mint SYSTEMS FOR STING Er WATERYAIN 11/2" W /BOX TENANT A w /BOX • 1- 8 TEE 1..._ 1 -r GATE VALVE, YJ 1- 12" X8" REDUCER, U W/THRUST • BLOCKING • <if] 1 3. - - 1- 12'X8" REDUCER, MJA' 1 -8 TEE, FL 2- 8"GATE VALVE, FLXMi W/THRUST BLOCKING 1 LOCKING r C EXISTING OFFICE BUILDING VICINITY MAF NTs VICINITY MAP NTS ..; SITE I; VI 0 21.1: L� v ,� FINISH FLOO FINISH GRAD �pe wink 1NS7�LL (z) I %Z" WA7ee. MSS IN XK771`4r Oj?C CALL PVAIER. p(PrNZT LaMPL�T�17 UN P�� �AviA? POW, t7"' i'wg4- cr � 17LF OF 6" DI PIPE 11 /2 w /BOX W U 0. z w Itc PRIVATE DRIVE UNDER- 5EP?4TE PERM SITE PLAN MI '16 0006 1 -11'X1 X 1 -8' GATE 1 -12 - GATE W/THRUST e oP kyckk_ (2.) Ire vvAze X('371tr METE ecx wActoe. P(PN4- pLv Ut-42e12. ApA- Pew tr q4-cezr) 12 PIPE (Cuss 52) SITE PLAN MI 0006 TENANT C 11/2 W/BOX 1-12 TEE, FL 1-13 VALVE, 1 12 VALVE, W/THRUST BLOCKING Er FIREMAN W P 02 11 4 E FINISH FLOOR 27.50 FINISH GRADE 26.50 / "ry OF a' 1 PIPE (CLASS 52) AA010 1 W /BOX 6 PIPE (CLASS 52) + STORM DRAINAGE SYSTEM-SEE SHEET 2E 1-12 MI THRUST BLOCKING TENANT B )7 (TYP) <1. TRECK DRIVE Y BUILDINC CATED WATER KETERS/PRV STATIONS AS PER APPLI WATER SYSTEM REVISIONS AS PER THE CITY OF REDESIGN SANITARY SEWER SYSTEM AS PER APPLI A MINOR GENERAL REVISION'S BY THS APPLICANT 08/3 1-± WATER SYSTEM REVISIONS AS PER THE CITY OF 2E J. i (T W OF NIS PIPE (CLASS 52) A 6" DI PJP-E Kiva 15. BUILDING + CATED WATER METERS /PRV STATIONS AS PER APPLICANT 09/90/94 WATER SYSTEM REVISIONS AS PER THE CITY OF TUKWILA 09/21/93 REDESIGN SANITARY SEWER SYSTEM AS PER APPLICANT 09/11/93 ICNOR GENERAL REVISIONS BY THE APPLICANT 08/31/93 WATER SYSTEM REVISIONS AS PER THE CITY OF TUKWILA 07/21/93 115 F."V DIRECT- BURY INSTALLATION LIMIT CITY OF TUKWILA'S APPROVAL THIS PLAN IS APPROVED FOR CONFORMANCE WITH THE CITY OF TUKWILA' S REQUIEMENTS, SPECIFICATIONS AND STANDARDS, AND CAN BE USED FOR CONSTRUCTION OP THE IMPROVEMENTS SHOWN HEREON. APPROVED BY DATE APPROVED: CONSTRUCTION NOTES~ 1. ALL WORKMANSHIP AND MATERIALS SHALL CON? TUKWIIA'S REQUIREMENTS AND SPECIFICATIONS. TE SHALT. MEET, OR EXCEED, CITY OF TUKWILA STAND 2. THE CONTRACTOR SHAM. INSTALL. THE WATER Al IN ACCORDANCE WITH THE CITY OF TUKWIIA'S STA TYPE OF HYDRANTS, VALVES, BEDDING MATERIAL, I COMPACTION DEGREE, CLEANOUT CONSTRUCTION, T METHODS, ETC.. + 3. THE CONTRACTOR SHALL. CONSTRUCT THE LAND: AS PER THE CITY'S STANDARDS WITH DSHS APPRO VALVE AND EXEMPT METER. THE SYSTEM AND MET TO BE DETERMINED. 4. ALL WATERMAINS SHAM. BE DUCTILE IRON PIPE MINIMUM COVER OF 42 INCHES (42"). CAI S V UCT1ON NOTES MI 9600b6 ORK1UNSHIP AND MATERIALS SHALL CONFORM TO THE CITY OF '3 REQUIREMENTS AND SPECIFICATIONS. THE UTILITY CONSTRUCTION OR EXCEED, CITY OF TUKWILA STANDARDS. CONTRACTOR SHALL INSTALL THE WATER AND SEIrER SYSTEMS RDANCE WITH THE CITY OF TUKWIL&•s STANDARDS, INCLUDING HYDRANTS, VALVES, BEDDING MATERIAL, BACKFILL MATERIAL, ON DEGREE, CLEANOUT CONSTRUCTION, THRUST BLOCKING, TESTING s, ETC.. + CONTRACTOR SHALL CONSTRUCT THE LANDSCAPE IRRIGATION SYSTEM THE CITY'S STANDARDS WITH DSHS APPROVED DOUBLE —CHECK EXEMPT METER. THE SYSTEM AND METER LOCATION IS YET $rERM NED. WATERMAINS SHALL BE DUCTILE IRON PIPE (CLASS 52) 1fITH A COVER OF 42 INCHES (42'). These plans have been reviewed by the Public Works Department for conformance with current City stancords. Acceptance is subject to errors and oml:sior �s which do not authorize violations of adopted standards or ordinances. The responsibility for the adequacy of the design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field inspection by the Public Works utilities inspector. Date: c7 / t By: PERMIT CENTER fi CAD FILE NAME: STRAND7.DRG XREF = STRAND4 /201 SEGALE RETAIL CENTER SO Mt WATER AND SERER PLAN Z RECEIVED SEP - 91996 TUKWILA PUBLIC WORKS RECEIVED CITY OF TUKWILA SEP 0 9 1996 MA SEGALE INC. TUKWILA, WASHINGTON pas) rm 3 .10 nsasna xwaEe 201 --93XXX