Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit B96-0248 - DANIEL BOONE PAINTS - STORAGE RACKS
City of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 RACK STORAGE PERMIT Permit No: B96 -0248 Type: B -RACKS Category: Address: 15701 NELSON PL St: 01 Location: 15701 NELSEN PL S Parcel 1: 000580 -0026 Zoning: M1 Contractor License No.: BROOKCI082LW TENANT DANIEL BOONE PAINTS 15701 NELSEN PL, TUKWILA WA 98188 OWNER NELSEN PLACE 15701 NELSEN PL S, TUKWILA WA 98188 CONTACT WILLIAM W BOONE 15701 NELSEN PL S, TUKWILA WA 98188 CONTRACTOR BROOKE CONSTRUCTION INC. P.O. BOX 1652, AUBURN, WA 98071 Status: ISSUED Issued: 09/18/1996 Expires: 03/17/1997 Suite: Phone: 206 228 -7767 Phone: 206 228 -7767 Phone: 206 824 -5604 ******************************************** * * * * * * ** * ** * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALLATION OF RACK STORAGE. UBC Edition: 1994 Valuation: 6,000.00 Total Permit Fee: 189.71 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** /?'9,1a Permit Center thorized Si at a Date 9 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this buildin• .ermlt. Signature: Date: Print Name:___ � Q66(44)/( Title: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. ' 0 GUY OF TUKWILA Address:' 15701 NELSON PL St: 01 Suite: Tenant: DANIEL BOONE PAINTS Type: B-RACKS Parcel #: 000580-0026 Ak**k***1444k********************kblckkk**k**k***kAkkk**k*kkli*kkk*kkk*kilkkk*** Permit Conditions: 1. No changes will be made to the plans unless approved by the ) or Engineer and the Tukwila Building Division. 2. All permits, inspection records,', and approved plans shall be available at the j0,6 site prior to the - start of any con- struction. Thes'etiocuments are to be maintained and avail- able until finl'inspection 'approval is granted. 3. Validity of Permit The issuance of a permit or approvald'qf plans, specifications,-.and computations shall not be con- strued to be a'permit for, or an approval of, any violation of any - of the provisions of the building code or of any' other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 4. AWConstrUction to be done in conformance with approved Plans'and 'requirements of the Uniform Building Code (1994 Edition) as amended: Permit No: B96-0248 Status: ISSUED Applied: 08/16/1996 Issued: 09/18/1996 Project Name/Tenant: n Id l3� /n r CJ. Value of Construction,' , ma. Site Address: City State/Zip: / 57 100/5e41 r t. S /A 0 A gf3,gg Tax Parcel Number: boosBO- r cZ(, Property Owner: if ❑ Multi- family ❑ Warehouse El Hospital ❑ Motel /Hotel ❑ Office ❑ Other l! / .••• Phone: 220 -71(01 Street Address: e ! Will there be rack storage? gi yes ❑ no r / /1 City State /Zip: Fax #: ZZ 171 U Contact Person: Phone: Street Address: 15 ?V I rklse . P` City State /Zip: So j ak A l.ii I3. leif Fax #: Contractor: Phone: Street A ress: r . G„ � r 1652- City State /Zip: 1 W A rg94o - 1 Fax #: Architect: Phone: RECEIVED cm( pF TUKWILA Street Address: City State /Zip: Fax #: t - . Engineer: Phone: PERMIT CENTER Street Address: City State /Zip: Fax #: Description of work to be done: AlJ Dlni. g s l yil<2 - 0 In use: Retail Restaurant ❑ Church CR Manufacturing ❑ SchooVCollege /University LI Multi- family ❑ Warehouse Hospital ❑ Motel /Hotel ❑ Office ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Church p Manufacturing ❑ School/College/University ❑ Multi- family ❑ Warehouse El Hospital ❑ Motel /Hotel ❑ Office ❑ Other Will there be a change of use? ❑ yes C71 no if yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? gi yes ❑ no ,�/ Existing fire protection features: In sprinklers In automatic fire alarm ❑ none L�!f other (specify) ,'4G r& rt. Building Square Feet: Z DOD existing Area of Construction: (sq. ft.) t t '7 $ 2- Will there be storage of flammable /combustible hazardous material in the building? ❑ yes ❑ no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets ommercial / Multi - Family Tenant Improvement / Alteration Permit Application CTPERMIT.DOC 7/9/96 CITY OF T'' Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 FOR STAFF USE ONLY Projict Number Permit Nutrlbir 616 -a.mg Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Curb cut /Access /Sidewalk ❑ Flood Control Zone in Hauling 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sewer Main Extension 0 Private 0 Public ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only ❑ Channelization/Striping ❑ Land Altering 0 Cut cubic yds. ❑ Sanitary Side Sewer #: ❑ Storm Drainage ❑ Street Use ❑ Water Meter /Exempt #: Size(s): ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: Avuusr t& VV1olt Ft(3i zinif PI 16 gal Schedule: Application taken by: (Initials) BUILDING ONEs OR AUTHORIZED AGENT: Signature: /. A. /f,...- Date: S i( _ 7 6 Print name: G J /1 (A, (a b V ,L --- Phone: Z - Z v „ 71 vi Fax #: •Z Z ---/ -7 7 Address 5-57 `.Ze /,. .) c: s Cit /St to /Zip 4, Cr ALL COMMERCIAUMULTI- ILY TENANT IMPROVEMENT/ T BE SUBMITTED WITH THE F RATION PERMIT APPLICATIONS OWING: • ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED , l Complete Legal Description L ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). is live (5) sets of working drawings, which include : Site Plan (including existing fire hydrant location ❑ ( 9 9 Y location(s) o( a land use or SEPA decisions. CTJ'ERMIT.DOC 7/9/96 RECEIVED CITY OF TUKWIIA PERMIT CENTER 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). • ❑ Floor plan: show location of tenant space with proposed use of each room labeled LN ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ Mr Vicinity Map showing location of site ❑ Lld Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack Structural calculations are required for rack storae eight feet and over. . 7 C:1 Indicate walls being demolished ( ❑ Construction details ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or ,-•y exceed sprinkler system design criteria as identified by the Fire Department. lJ ❑ Washington State Non - Residential Energy Code Date shall be noted on the construction drawings. a ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ a Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Certificate of Contractor ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. :i*kli*A* icli**** A* k: 4* A* A: k*• Ai , A*Ah*l *kkk ****** k.4A•k,t•k+h: *4A* CITY OF TUKWI:LA. WA TE'HN1MIT **A*** * k*: k*4-* AkA* A** A * *k *kki. **4.** * *.k *Aqt **A:4kk**A:k*k•kk TRANSMIT Number: R9600465 Amount: 189.71 08/16/96 10:22 Payment Method: CHECK Notation: DANIEL BOONE PNT Init: MEV Permit No: 896.0240 Type: 8- RACKS RACK STORAGE PEiti4IT Parcel No: 000550. 0026 Site Address: 15701 NELSON PL St: 01 F1: Un: Location: 15701 NELSEN PL 5 Total Fees:.. 189.71 This Payment 189.71 Total ALL Pmts: 189.71 Balance: .00 *** k** A*• a*** *A *•k**k *i * * *•4• ** * *4* ** * *:A*** *fit &••k * * *** * *+ * *•A** k * *•k* Account Code 000/322.100 000/345.830 000/386,904 Description BUILDING - NONRES PLAN CHECK.- NONRE6 STATE BUILpING SURCHARGE Amount 1.12.25 72.96 4.50 2330 08/17 9619 TOTAL 189.71 Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: City of Tukwila Fire Department Project Name 04 hid I3oohe PGin +S TUJ WILA FIRS IMPARTMENT FINAL APPROVAL FORM Address /.S70) J e Leh Pi— Suite # Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Permit No. a 94 .- O g LIP f � s // /o /p/ ? Aut Signature Date FINALAPP.FRM T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Flee Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 -4404 • Fax (206) 575-4439 :: e, res , ate c alled. Specia instructions: Date wanted: j2 /o W. Requester: W 7� 4 T� Phone No.: KS Approved per applicable -- 1 Cartections required prior to approval. COMMENTS: lir, A'A INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILbING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 Date: • (206) 431 -3 $42.00 REINSPECT • FEE REQUIRED. Prior to inspection, fee must • be paid at 6300 South enter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 2\7 .,.L'n ...130/4k:% .3.3k _ .! sw.d.4 . r COMMENTS: 0 4 7 /:)U 1--"C“--4C---S Type of inspection: ,.� do /ya a l�J 3 lOOD / ■ s_ ' Date called: //),4h1 46.07 .--, r12.7‘,/ Date wanted/0_ g_.? d in Requester: 4 i of 2.3 "Foosi--- /04fae /? s .._ 6 _ _ _‘ � . / A it L / / _ Z /� Project: J t .. / Type of inspection: ,.� Address/ 5.7a/ y/ A ' Date called: Special instructions: /,-oo Date wanted/0_ g_.? d in Requester: Phone No.: � ,. �y 1 INSPECTION RECORD Retain a copy with permit' INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 Approved per applicable codes. Corrections required prior to approval. Inspect /( /�' `` �� "✓ yew Date ,Q q $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: a m'r.e, / /3vvel0 A Address: / S 7 � , `� � /�/� Say C� Date called: Special instructions: Date wanted: 27�/ C� a n p.m. Requester: Phone No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 IpkApproved per applicable codes. 1 Corrections required prior to approval. COMMENTS: ok T /C'ef a $42.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: � I coklaze.i - s�tlhT 62.&C AS ht�vng -51-01'5-* L 1 -f — ? o !��a.iN - I -5E61'4 Imo! STEM \N./A-LL TIP FILE COPY exIA7T A,G. PAS/$ -J AUG 1 6 PERMIT CE Project: -VP+4-1 I L F64i--rrS BROOKE CONSTRUCTION, INC. P.O. Box 1652, Auburn, WA 98071 (206) 622 -3775, Fx 622 -3874 Cola C_,00Apa SHOP DRAWING Description: sPlu.. co‘tt'ai► -1 Mektr Drawing No. RECEIVED LITT - O*-'UINVILA ER ctgletto 111111 NNNNNN ;WWW g N FOAARMA 3 L(.14,-"J Zr /OV.0 17 l 4-<.. S� PA E r 14-Cgs r=''r' c. A-0% C- nom * P -sAl-71 , 7J K&t Ices Tic: /494- Lac. c A4-P 2 2 DiJl.t �o•rJ Y1, o C OMP l & v 7" (, c ig Nr) Ma) 3 0) Ea4& 3 C. hla-ni&'L 7• N — �a//. ; T' )4Q ritAistEf - r4,410/44) t die 2 em '� ! e. Eve ryrt 44 c rc D G fri) L.,44, t(AiU ✓ PL,' owr.r t . 4- tr)l,l r . o - r174 , u llO 41 St-vs v1 • SGIS rbL c. (1 LAS i." /3Tk 8 -96 Ca p - 0 '4 aillA d St) rx pi, '.J Lsto S et' p — 1 2.0.3 - G :'s • ane LOA-0 ' & 20 3 sky 'me =7 EXPIRES 7/14/ yP' � "J °631 RECEIV =D CITY OF TU WII.A Lt1G 1 6 PERMIT CE TER 71 32 t - 869 4 l4A — 2Sg 0 .1 , 94 - F , ©•;�4 ) - o.523 C$() .! 0,8st (.1.4-) = I - 70, 33 k Cv1 c.u- tc 1„) + v La4.0 L M' , 4iZ & A ?. tr l ( 2-) 2!0. 5(-1, ?nu.. 1,10 a 1:- 44 - 3 : 44 h S 4 S P I e" `7 . 9.Q ` GP-At 0) R. S.'jp m4-3e (s oar ! 9 es -I ` To° 1 &t)Et t-0 4 twLtr .00 ; c:x T7 G,R-L F�/� ELTsFE�2 1.- C1 2 i 9 << ,�,,, '1 ? ?A• $6 ,t (d. f,,-1 �roev s �, !v 6 C,fir.t,/ S 4. 4 Q 0,4 0.4 ;'i1 Tr. I,(oG ( 2SR) /3 — 14-3.53 r<" U Lid r1-.4 rrg IA( 1- 17 - ,i + V A/A = 3 t 0, 2 e - o. C. 4 /. o gQ,t -c tr; r, : 40411 -r V z /, 649 6844E .2- - 0 L 4).1 02.61)/. 40 43 = ) 3 ¢, 6t 1?, 4Z. O $ y F .. 1 5 , 2G3 1.36 4. 3, ! - �o LL ?_ / /1 4' x 33/4 4 .•:P. Lrr ,Z4 74 5.z 75'//, r f,o2 k Vp Irm a 0.6 FS 1 3, U , / y ,t'u- IS/Wit 0,Ard 4. � 3 , 6 e ' .. ks� C'k C PI! at.) • C - c . 1 _ !, v .":". u 1 P.441' 0- ik O,35 C2.0) /2 x.70 = '� /.. •;=Irj . It/ j /1., I p 4 I ,, / 2YE.3 "- 1 R,d,c,` P 9 � ►G rip E-S % 14- C9/4 S s 0: a. Z 4-I A 2" 0,283 ,,� v. o, ! r�. . •, 34 -3 S.o 877e ?/P6, r �. �. ..G (Z V.a- w 60186D) pa-it d il-S6. PIAni c { 1k .) (- raz k0 2, W L't SPfCL /I4 Lr1SP La,J ,r113 /IA y ill'. :n M (; : 2, o �� ., ).1 Al .7 ' . 's - 1 2.. ? .ei a _ 3,34 -- - ; 3:1. 114 rim r. $.Rs L 205 w 1 (.01 , i SEtOMcc. t-Els Avw.. V 0.3. /03 ‘2, 3' 2,0/2 z D. 3 D J li Let # e t.J i a♦ *OA 4, o ( 4010 .) s 13.33 1: wlaA V 7 - ; . 3 ; .. 1414 3nA.6 Dtt T 4t 4 u'Y t.n S 'r - 1' t s f 3 L4(.044.641- 6 os A 61L42 V - D.814 / 3 = D. Z7 " cat, J�is,yaa yr 9, 03?4- F2 p. /o3 ,E a- (3 ) (Z) 66),f74.1 A L& 4o4- 13 . 3 .4 0 /2., + 0.2 2.0 k C.AuE--t. e 1144. .1.E- 2237. S. 4 ) trk 2S f3itc Oc. ,1 % sq - 7,0 12 -¢- k'" . 0,1b8 &- £z) 66 ,f4-A4 otos cg4nc4c 7 •: 7. Z. 0 .a 12 d• SFro 4 1 3, S7 !c 0.9¢8/ 14, 63 Z JtJ S t�0 ° A L LO .-ti 114 q % 4 G /' 4 Ca A/77 (fit to A IS °`• A 1=64 d ;Ty L e - 1 N 6.'140 7- 5 .4 -9/. 4- b C106`s-) SZ ok < 7 4. PI z 0, 3.go/2)(10/>) . 2) . 4 PLOk - 22 . s? � k ob G � .4 Ft( — 3o t4.42 5( Mob-) (Lo0 0,25' _ 2,4.14 64- 2R Se e, x 1,0512 Lilo = 9. 7:1 4 , �C 05 " —) 7 '2 y r'J L 9'c • L ✓' a , •/ r /l� • 60'3.5 1712-41.fie - -� 0 4715 ' ' 0 - : - : )r 4 N Q5 71.E $ )11 ;II) •Qi - "-t- L , z 14 gut /! , zZ '& = - Qs c ,, Q1- ' S = d 1E6 '0 =q ca hr? t .r1y�'t7��7 �'C� ; s'N'''''r r°? 7g: a y.;..., •.4j •• • • et -" 3 ),'a y - . MODEL HEI S C 8 In X in TIX S 1n ` x C r C Sy 1n rr In AREA 1n LM 15 .075 3 1.625 .689 .582 .388 1.156 .205 .219 .686 .411 LM20 .075 3 3 1.435 1.023 .682 1.263 .872 .557 1.165 .618 LM30 .105 3 3 1.45 1.373 .915 1.249 1.164 .752 1.15 .859 LM20/ 15 '0 075 3 4.625 2.607 1.78 1.187 1.231 2.577 .988 1.481 1.143 LM20/20 ° 7 5 3 6 2.714 2.222 1.481 1.268 4.701 1.431 1.845 1.349 LM30/ 15 7 3 4.625 2.789 2.126 1.417 1.23 3.052 1.094 1.473 1.384 LM30/20 '1 75 3 6 2.951 2.568 1.712 1.262 5.45 1.788 1.838 1.590 LM30/30' 0 3 6 2.707 2.98 1.986 1.2566.387 1.94 1.839 1.875 COLD N SECTION PROPERTIES -*.-1- .87 c,.- L t LM X B r ;INGEY DATE BAPR.'91 NO. LM__/ R -2 REVISION DATE BY X GAGE T In X in I x in Sx in rX in I y in SY in ry in AREA i 16 .060 .4189 .0893 .1'190 .0234 .0379 .0456 .4066 .2297 14 .075 .4261 .1081 .1440 .6169 .0464 .0564 .4043 .2839 12 .105 .4405 .1418 .1890 .6041 .0621 .0767 .3999 .3885 10 .125 .4551 .1706 .2275 .5914 .0764 .0960 .3956 .4878 10 9 0 0 Qz O = J O J < o X Q 0 ma Q = o 3 Q z 8 7 6 5 4 2 1 BRACING SECTION PROPERTIES H= 1 1/2 I iimommumimmummi \ \M0\\ \ \ \ \11111\\\ yr ■V ■ ■ ■■111111■ ■111 ■ ■ ■ \11111■■ • ■\1111111111\\\11111\\ :2111111111■ ■ ■1M 10 G \\\fin ■ \\\ ■tin , III_iIIIII 1111111111111•1111111)._ mmun\► *R aimumwomnomminumumm no 14 Go \\ \\\ ��M\r\\ \ \■ ''■111\ ■ ►01r\\\\\\\\ \\ ■ \M\ \\ ■■ �\\\\a\ ■\ fin MIN rII ■ON■ \►\Si5\\\\M\\ ■ •111111\ \\ ■ \11•i_MIM \• 0 20 30 40 50 60 LENGTH IN INCHES • X B= 1 1/4 PREPARED BY P. TINGEY DATE 10MAY91 70 NO. DRAWING NO. R -3 REVISION Iiii DATE By 80 13.3 14.6 10.6 9.31 7.98 6.65 5.32 3.99 2.66 1.33 0 0 0 cn in J a � X a. LA- W 0 [D 0 a o o z Q J N � 0 tnz cn M BEAM SECTION PROPERTIES PREPARED BY P. S. Ting ey r DRAWING NO. R - 1 DATE 14 SEP.'93 REVISION NO. DATE BY MODEL ... C • = C • in C • I x in Sx in rx in I y in Sy in ry in AREA in LB020 .075 2 .75 .2928 .274 .716 .6033 .4133 1.031 .5718 L8030 .075 3 .75 .7604 .4659 1.026 .8786 .6054 1.103 .7218 LB035 .075 3.5 .75 1.1854 .6313 1.223 .9475 .6712 1.093 .7922 LBC30 .075 3 .75 1.3689 .8817 .184 .9403 .6099 .9820 .975 LBC35 .075 3.5 .75 1.951 1.0473 1.363 .9705 .6159 .9614 1.050 LBC40 .075 4 1.5 2.6631 1.2769 1.538 1.105 .7096 .9921 1.125 LBC45 .075 4.5 1.5 3.5073 1.5033 1.709 1.2449 .8025 1.018 1.200 LBC50 .075 5 1.5 4.6437 1.7655 1.908 1.3902 .9029 1.044 1.275 LBC55 .075 5.5 1.5 5.7951 2.0453 2.071 1.5269 .9975 1.238 1.350 LBC55A .105 5.5 1.5 7.7919 2.7571 2.038 2.0719 1.3498 1.051 1.876 LBC60A .105 6 1.5 9.587 3.1421 2.192 2.1979[ 1.4517 1.049 1.995 LB F356 .060 3.5 1.5 1.2039 .6277 1.274 .7576 .5097 1.011 .7414 LBF354 .075 3.5 1.5 1.4739 .7699 1.267 .9284 .6242 1.006 .9181 LBF404 .075 4 1.5 2.0512 .9481 1.437 1.0635 .7190 1.035 .9931 LBF454 .075 4.5 1.5 2.7526 1.141 1.605 1.1984 .8143 1.059 1.0681 LBF453 .090 4.5 1.5 3.2119 1.333 1.598 1.3985 .9497 1.054 1.2578 t-111. -- 2 3/4 -- 7/8 1 7/8 -- x x n BM 12- 9 4 • oa4e0 3- Pi/4 1,NT iteAdies mon8747 CA-PAC /'Y P11 /n4'rt'iai. COLUmM flA-re ,4i. /J AS $1 S10 GAR 5e, lA/rm FY So kst: w vri4 R met,. 0 '11 i'' /4. • o, 0928 I LJs IA v per+ F : � . 4 � Ft a- J', KiArCI iAL Aft US IN 6 1 47 ` .1 FP = 1.0 FA. P R CaLO114 N r1Nte i Pi Sj +E*2 t : I o7Z8 x0.444 USE ir- F,� _ 4o k .e 42 ;.• 0a 45 (cs,' II C1Olo • �l �x F : 44 la(' ti b� }S c+�c e ,4 LM Is viz LM 20 (t 0 `) 0//3z 0. a7s. 4,3 = / Comp. poets- g5141t14 C o L i 3o (t : 0, C64r Roo • = 61/31)A 0. /oS _ 2, 3 o.84 Awo ,: : 0.014 k A MA = I.63x4.1S+ 0.86x 2.75" 4- ,oel&x /0. /g Sus MA : )0.18 x 4/3 t,01.73 F“, ; 5 S k Lr 1 /4- Ber` 1.1- c, err 1.1115 (...ti t.3 hz.) 0,015) x r 1,41. 14.40 g eke r s) 0,4 Lki r 9 6. /3z, OS) (SC ) : 1, 9 y k n •, . o c":0, E../r'I ' A)7,14(4 $ /s ,JTT L:� MA, = (Mg/. (/.4z//.3. - l/, 8 2 LP, ; 1 r Q/- I M Zo Cr 4 t ' 4s 4%,-:) 13.57 kk Ln13o l de) .- 45" �c�.,f l Danield3vvne PAINTS Daniel Boone Paints, Inc. 15701 Nelsen Place So. Tukwila, Washington 98188 (206) 228 -7767 FAX (206) 228 -7770 10/15/96 NORA GIERLOFF PLANNING DEPT TUKWILA, WA 98188 DEAR MS. GILOFF, TO SCREEN OFF OUR NEWLY BUILT CONFINEMENT AREA, DANIEL BOONE PAINT CO. PROPOSES TO INCREASE THE HEIGHT OF OUR CURRENT 6 FT. CHAIN LINK FENCE TO 8 FT (60% OF THE 13.25 FT TOTAL HEIGHT OF THE FULL RACKS) AND FULLY SLAT THE EAST AND SOUTH SIDES BY THE CONTAINMENT AREA. IF YOU HAVE ANY CONCERNS OR COMMENTS, PLAESE FEEL FREE TO CONTACT ME AT 228 -7767. THANK YOU FOR YOUR HELP. WALT SADOWSKI 10/1416. 69croa tit g CITY RECEIVE T UK Q WILA OCT 1 5 1996 PERMIT CENTER 1 CITY OF TUKWILA Department of Community Development Building Division-Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 REVISION SUBMITTAL DATE: • / /v PLAN CHECK/PERMIT NUMBER: b - OAP, PROJECT NAME: vvrxe— PROJECT ADDRESS: /6 70/ 1\1 e 7 - 1 , CONTACT PERSON: W 6-1 4- PHONE: ‹g98 - 77 6 REVISION SUMMARY: A cv.e . SHEET NUMBER(S) NUMBER(S) . .-sc•to "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED TO: rse, RECEIV: U IIY 0!- 1 to 1 SEP 1 2 1996 KiP PERMIT CEN: iel/eCt 5 CITY USE ONLY , • •• . • ••• • ••••iPiitilia.Voik.::: 3/19/96 Vanield3vvne PAINTS Daniel Boone Paints, Inc. 15701 Nelsen Place So. Tukwila, Washington 98188 (206) 228 -7767 FAX (206) 228 -7770 9/12/96 Mr. Steve Lancaster Director, City of Tukwila 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Dear Mr. Lancaster: SUBJECT: Development Permit Application Number B96 -0248 Daniel Boone Paint has recently applied for a permit to install a racking system in a newly built hazardous material containment area. This area was mandated by the Tukwila Fire Department. Since this area is smaller than what we previously used, racking became necessary and hence the permit application. This application was approved by the Building Dept., the Fire Dept., and the Public Works Dept. The Planning Dept., however, rejected the application citing a screening ordinance (18.52.040 (4)) and asked for a resubmittal of the plan. We fully intend to comply with the regulation but we are now under a time restraint to get the project, which started in February, finished. After contacting Nora Gierloff and explaining our problem, she suggested that I write to you and see if we could get our permit approved with the stipulation that screening would be provided as soon as possible. If you or your staff have any questions, please feel free to contact me at any time. Thank you for your consideration. Sincerely, Walter Sadowski Technical Director RECEIVED SEP 12 1996 COMMUNITY DEVELOPMENT September 9, 1996 Mr. Walt Sadowski Daniel Boone Paint Company 15701 Nelsen Place South Tukwila, Washington 98188 Dear Mr. Sadowski: City of Tukwila Building Department: No Revision Comments Fire Department: No Revision Comments. Public Works Department: No Revision Comments. SUBJECT: REVISION LETTER #1 Development Permit Application Number B96 -0248 Daniel Boone Paint Company 15701 Nelsen P1 S John W. Rants, Mayor Department of Community Development Steve Lancaster, Director This letter is to inform you of revisions that must be addressed before your application for development permit can be approved. All revision requests from each department must be addressed at the same time and reflected on your drawings. The following are comments from each of the reviewing departments: Planning Department: Contact Nora Gierloff, Associate Planner, at (206) 433 -7141 if you have any questions regarding the following comments. 1. After review of the application I have determined that the proposed project does not meet planning standards for screening of outdoor storage areas. The addition of rack storage to the outside, unscreened storage yard is an intensification of a non - conforming area. I have enclosed the code section which covers screening of outdoor storage. I cannot approve this application for permit until a revision is submitted which provides the necessary screening. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 Mr. Walt Sadowski September 9, 1996 Page 2 The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431 -3672. Sincerely, ge Kelcie J. Peterson Permit Coordinator Enclosure CERl MAIL (also sent via fax on 9/9/96) File: B96 -0248 .1; . . . ,I:4 : P.O.. State and ZIP Code 10114 Postage Certified Fee Special 'Delivery Restricted Delivery Fee Return Receipt Showing to Whom & Date Delivered 1.10 Return Receipt Showing to Whom, r• and Addressee's Address ',. .1. Postage & Fees Postmark or Date MAILED 9/10/96 REVISION LETTER #1 .B96-0248: Receipt for Certified Mail No Insurance Coverage Provided :gomme tOornotiusejorilnternationaltMell ilSewileverse) .2 Z •019 851 620 . - . MEMORANDUM TO: Permit Coordinator FROM: Nora Gierloff RE: B96 -0248 Daniel Boone Paints Rack Storage DATE: September 5, 1996 After review of the application I have determined that the project does not meet planning standards for screening of outdoor storage areas. Please inform the applicant that adding rack storage to the outside, unscreened storage yard is an intensification of a non- conforming area. I am enclosing the code section which covers screening of outdoor storage. I cannot sign off on the permit until a revision is submitted which provides the necessary screening. Chapter 18.52 LANDSCAPE, RECREATION, RECYCLING/ SOLID WASTE SPACE REQUIREMENTS Sections: 18.52.010 Purpose. 18.52.020 Landscaping requirements by zone district. 18.52.030 Special landscape requirements. 18.52.040 General landscaping and screening requirements. 18.52.050 Landscape plan requirements. 18.52.060 Recreation space requirements. 18.52.065 Lighting. 18.52.070 Recycling storage space for residential uses 18.52.080 Recycling storage space for non - residential uses. 18.52.090 Design of collection points for garbage and recycling containers. 18.52.010 Purpose. The purpose of this chapter is to establish mini- mum requirements for landscaping to promote safety, to provide screening between incompatible land uses, to mitigate the adverse effects of development on the environment, and to improve the visual environment for resident and nonresident alike. (Ord. 1758 §1(part), 1995) 18.52.020 Landscaping requirements by zone district. In the various zone districts of the City, landscaping in the front, rear and side yards shall be provided as established by the various use district chapters of this Title. Minimum required front yard landscaped areas in the MDR, and HDR zones may have up to 20% of their required landscape area developed for pedestrian and transit facilities upon approval by the Board of Architectural Review. (Ord. 1758 §1(part), 1995) 18.52.030 Special landscape requirements. The required landscape areas shall be increased by a minimum of 25% or 50% or by construction of a decorative fence or solid planting screen, to be approved by the Director, along the applicable front, side - and /or rear property line(s) in the following circumstances: (1) 25% increase with a minimum of five feet when: (A) Office use district occurs across the street from a single- family use district, (B) Commercial use district occurs across the street from a single - family use district, (C) Industrial use district occurs adjacent to an office use district; TITLE 18 — ZONING (2) 50% increase with a minimum of five feet when industrial use district occurs across the street from a single- family or multiple- family use district; (3) Installation of a solid planting screen within a ten -foot wide landscape strip with a height of five to eight feet or the construction of a decorative fence, to be approved by the DCD when: (A) Commercial use district occurs adja- cent to a single - family use district, (B) Industrial use district occurs adjacent to a single- family or multiple- family use district; (4) Fifteen feet of landscaping shall be provided when a nonresidential development in a Commercial/ Light Industrial district or a Manufacturing Industrial Center /Light district abuts or is across the street from residential uses. This landscaping shall be outside of any fence used to prevent access to the development in a C /LI and MIC /L district. (Ord. 1758 §1(part), 1995) 18.52.040 General landscape and screening requirements. (1) Landscape Architect Required. In the MDR and HDR zones, a Washington State licensed landscape architect shall prepare and stamp the landscape plans in accordance with the standards herein. (2) Coverage Standards. All landscaped areas (including shrub beds) shall achieve 90% live ground coverage in three years and all areas not occupied by a building (including surface parking areas) shall achieve 40% horizontal tr. a�.Yera.g . in ten years. y M - 2cm.5 (3) Visibility. The landscaping shall not ob- struct view from or into the driveway, sidewalk or street. (4) Outside Storage Areas. Outdoor storage shall be screened from abutting public streets and from adjacent properties. Such screens shall be a minimum of eight feet high and not less than 60% of the height of the material stored. Said screens shall be specified on the plot plan and approved by the Director. Except in the MDR and HDR zones, where outdoor storage shall be fully screened from all public roadways and adjacent parcels with a sight obscuring structure equal in height to the stored objects and with exterior landscaping. A top screen cover may be exempted if the item(s) has a finished top and an equivalent design quality is maintained. The screening structure shall reflect building architecture as determined by the BAR to be appropriate. (5) Parking Area Perimeter. In the MDR and HDR zones, all parking areas shall have a perimeter landscape strip. This strip shall be a minimum of 2 feet wide and have ari average 5 -foot width. (6) Interior landscaping for each distinctly separate parking area. In the MDR and HDR zones, landscaping within parking areas shall be provided as shown below: December 4, 1995 Page 18 Wi :. +1.ioz. ;VwftAriP ,gw'i.:4w44i*:: 14:ecu- :arlrow,cx.s�x <e`�z5:. an:x�ksu:�A Fire Department Review Control #B96 -0248 (512) Re: Daniel Boone Paints - 15701 Nelson Place South Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. 2. Storage of flammable liquids on racks shall be within the designated area. 3. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The cc: TFD file ncd C City of Tukwila Fire Department -4L la Fire Prevention Bureau veteitretvia O tffkO «'PJGWscoerstrovtavuouvr,r4N 1` rns.rAtrmvt '.V.rimmu Wrwort fMMVotorH∎rtorrU rtseM.N4itRMduogi Arx .. August 29, 1996 John W. Rants, Mayor Thomas P. Keefe, Fire Chief \ Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax.(206) S754439 m.n.. >.v... .wn:'aVAiX;;0 :10A9PVI.! t'MANe44MCA ttlaa0.0MA3L'.+A: ilalNCt7taualel eNtl. u.a..e[,...w.'1.'.►*n. City of Tukwila August 23, 1996 Department of Community Development Steve Lancaster, Director Mr William W. Boone 1571 Nelsen Place South Tukwila, Washingotn 98188 Dear Mr. Boone: SUBJECT: Development Permit Application Number B96 -0248 Daniel Boone Paint Company 15701 Nelsen P1 S This letter is to inform you that your permit application received at the City of Tukwila Permit Center on August 16, 1996, was reviewed at the August 20, 1996, plan review meeting. Your application was determined to be complete. Your permit has begun the plan review process, you will be notified of any corrections or when your plan is approved. If you have any concerns or questions please contact me at the City of Tukwila Permit Center at (206) 431 -3672. Sincerely, i CA—e_. i Kelcie J. Peterson Permit Coordinator File: B96 -0248 7e FILE COPY John W. Rants, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 Aug. 1.6 '96 14:58 r BROOKE 0 f -00146 O'S21. J e p ob -oI - 9-7 FAX .7'466223874 ,3 Vt(o�DufB e. 130ovie P� STATE OF WASHINGTON CITY OF P. 1 1 9 1g PER _ r C ,-O " AUG vv lanmu (TYP) E?Ab ovri 66' -0" (TYP) FLOOR PLAN SCALE. 3/8 " =1' -0" ro w_ ck ePProvals ara , nrl aPPro .>I 1 .4 %9Y2,. 9 AU6 1 6 1996 PERMIT CENTER 0 0 0 0 01( ❑ ❑ ! .531 SQUARE ' 2" TYP AS NOTED 8 — 375 R LM 20: UPRIGHT COLUMNS - .075 THICK 1 1/2" O STRUT .075" THICK g7qb • Ot1I 8' - 10" TYPICAL RACK ELEVATIONS BRACKET ASSY - -� AS NOTED BEAM SECTION U/5" THK. ASTM A570 GR50 0_ LBF 404 LOAD BEAMS 2 3/16 V `3/16 .ter \TYP 7/8 " 1 5 1/4" BASE: 3/8" THK A36 MILD STEEL NOTES: 1. PALLET RACKS ARE MED BY LODI METAL TECH, INC., OF LODI, CALIFORNIA. 2. STEEL USED IN ALL RACK ELEMENTS CONFORMS TO ASTM A570 GR 50 WITH Fy =50 KSI, AND F,65 KSI. 3. STEEI. USED IN ALL BASE PLATES CONFORMS TO ASTM A36 WITH Fy =36 KSI, AND Fu =58 KSI 4 MAXIMUM RACK LOADS SHALL BE 36001bs PER LEVEL PER PAIR OF BEAMS. 5. CONCRETE SLAB IS GIVEN AS 5" THICK, WITH fc'= 2500psi 6. ALLOWABLE SOIL BEARING IS 1500 PSF FOR GRAVITY LOADS, AND 2000 PSF FOR SEISMIC OR SEISMIC + GRAVITY LOADS. 7. ALL RACK UPRIGHTS ARE 1820 -44 -144 8. ALL RACK BEAMS ARE LBE404 -106 9. BEAM -TO- COLUMN CONNECTIONS UTILIZE 3 -PIN BRACKETS AND "A" TYPE WELDS. 10. TIE -DOWN ANCHORS SHALL BE HILTI KWIK - BOLTS, USE 1/2"0x3 3/4' BOLTS, @ 2 1 /4" 811. EMBEDMENT, TWO PER BASE PLATE- SPECIAL INSPECTION IS NOT REQUIRED. FLOOR ANCHOR DETAIL SEE NOTES FOR SPECS. 7 RECEIVED COY OF TRIONIIA AUG 1 6 1996 REPAIR CENTER U 0 m 5 C c 5 (I) F— Z _ Q 0_ w z 0 0 _J W z