HomeMy WebLinkAboutPermit B96-0262 - PRIOR / MARTECH - PARTITION WALLSCity of Tukwila ` .. (206) 431 -3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
BUILDING PERMIT
Permit No: 896 -0262
Type: B -BUILD
Category: ACOM
Address: 16000 CHRISTENSEN RD
Location:
Parcel *: 252304 -9077
Zoning: CM
Type Const: III -N
Gas /Elec:
Wetlands:
Water: TUKWILA
Contractor License No.: MATRICC088DK
Status: ISSUED
Issued: 09/30/1996
Expires: 03/29/1997
Type of Occupancy: OFFICE
Slopes: N
Sewer: TUKWILA
TENANT PRIOR /MARTECH
16000 CHRISTENSEN RD, TUKWILA, WA 98188
OWNER JOHN HANCOCK MUTUAL LIFE Phone: (206)431 -8336
16040 CHRISTENSEN RD *214, TUKWILA WA 98188
CONTRACTOR MATRIX CONSTRUCTION COMPANY Phone: 206 524 -6901
3023 N.E. 50TH STREET, SEATTLE, WA 98105
CONTACT CHUCK MAHLUM Phone: 206 241 -5258
16000 CHRISTENSEN RD *101, TUKWILA, WA 98188
******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit Description:
CONSTRUCT PARTITION WALLS.
SETBACKS
Units: 001 Front: .0 Back: .0
Buildings: 001 Left: .0 Right: .0
Fire Protection: SPRINKLERED
UBC Edition: 1994
Valuation: 21,500.00
Total Permit Fee: 519.71
******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit Center Authorized Signature. Date
I hereby certify that I have read and examined this permit and know the
same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate
or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign for and
obtain this buj..ding permit.
Signature:
Date: JOY
Print Name: Lce5
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or
abandoned for a period of 180 days from the last inspection.
0 � >
CITY OF TUKWILA
Address: 16000 CHRISTENSEN RD Permit No: B96-0262
Suite: 310
Tenant: PRI0R/MARTECH Status: ISSUED
Type: 8-8UILD Applied: 08/29/1396
Parcel #: 252304-9077 Issued: 09/30/1996
**x**+***m+****w**+***k**^*+*+***********W*Ak+*****x**4:+*+xAw*^*k^*+^****
Permit Conditions:
1. No changes will be made to the plans unless approved by the
Architect or Engineer and the Tu la,Building Division.
Z' Electrical permits -beobtatned-through the Washington
State Division of,Obor and Industr�es aMd electrical
work will be i ' 630)
3' All mechanicark
the City
4' All permitinspection records, and approved planS shall be
' d ' il
able until final inspectionapproval is granted:
5' A ny neW:ceiling grid and liaht fixture installation is
G' P t
=
7. AnyexpoSed tnsulatiOps backina materiat have a Flame '
shall . Spread Rating of-:25. or and..material bear identi_'
fiCaion,,showina h f f ormance rating thereof.
8. AYI:':co uution t0 be dmne.`jn confommanue:with approved
Code (1994
Edition}as amended, 'Uniform Meuhan1cal.:Cude (1994 Edition),
and' Wmshint. Ct/te'E��ry C�de(l994 Edition}.
�
VaI � issuahce. of a .pArmitor approval of
pla i Cations, and oompu�tations shall � nut be pp_
str6 0, m!a permit for, or an� o
apnroxal f, any violation
of a nyo � e provisions i s i ons o � u of th b j ldi ng�oue - � or V any
f v
'
otherOrdinanoe uf/ the jurisdiction, ' No Permit presuwin8
� authority to violate c n � the �u i iu
� ve � r y v a e or a �e p v � nso f this
code snail be .
10' VENTILATION IS REQUIRED FOR ALL NEW .ROOMS AND SPACE3.DF NEW
OR EXISTING UILDINGS IN CONFORMANCE WITH THE UNIFORM
BUILDING CODE AND THE WASHINGTONySTATE VENTILATION AND
INDOOR AIR QUALITY CODE, CHAPTER_ 517.I3 WAC.
``
[
Project Name/Tenant: ® ��
Jj /UC/- IJiF�/iJ t* LrC �' r"/� J��,+- /�.�' / -TG-
Value of Construction:
p7/ ,O .—
Site Addres): City State /Zip:
/4(vn IA,.-/sr# ,,) An 51f',.3 T /I:o z . (DA °d' /Se3
Tax Parcel Number:
c i <23c - 1C77 -o
Property Owner:
"n";,/,1,0 aalNr,, _ 1 I LI
Phone: .�
3 — y60
Street Address: City State/Zip:
e/
4de7�- 1,,,.),., ()n)tai) S? . 6"( L2)iz�,J &A. 0,1 . 'l0 /
Fax #:
r �/ t�
35 [ 'T I t
Contact Person: /-7 / , � / ,
l : M J / —
Phone:
(2 24/1- 5 Z S 6
Street Address: , City State /Zip:
//,/,, srfm& £ 5 /" / l u,Lwi«•: lJ� ( 71/86
Fax #:
,,V9/ - 7S/Z
Contractor: �1
f / %4 T/' /X (20 57/' uUTi D , n
Phone:
5.244 - 6 0 Li
Street Address: City State/Zip:
- 3o, - :,s ,O.f . 5o St vt"ATu. 1 O 4 161 oa
Fax #:
52-4 -(
Architect: /`
CD,o 4)FU_ '.S/ C3 0z)(
Phone:
A 10 — 6706
Street Address: City State/Zip:
A9 2n_ 0 2.;-'o -1 . s, co STL" ca lift. U. "i'h4z3
Fax #:
77e1 - ffin
Engineer:
Phone:
Street Address: City State/Zip:
Fax #:
Description of work to be done:
(o, Si 4.c - T i a ) !1 F ` K C / . . .I T &,) (A)A 445, / 1C cc; � r rc.4 i, 7 414
Existing use: ❑ Retail ❑ Restaurant
❑ Church ❑ Manufacturing
❑ SchoolCollege /University
❑ Multi- family ❑ Warehouse r3 Hospital
❑ Motel /Hotel , Office
in Other
Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse in Hospital
❑ Church ❑ Manufacturing ❑ Motel /Hotel Office
❑ School/College /University in Other
Will there be a change of use? ❑ yes no
If yes, extent of change: (Attach additional sheet if necessary)
Will there be rack storage? ❑ yes pr no
Existing fire protection features: sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify)
Building Square Feet: `g•,7 ° existing
Area of Construction: (sq. ft.) /r0 L
Will there be storage of flammable /combustible hazardous material
Attach list of materials and storage location on separate 8 1/2
in the building? ❑ yes no
X 11 paper indicating quantities & Material Safety Data Sheets
CITY OF T' IKWILA
Permit Center
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
(206) 431 -3670
Commercial / Multi - Family Tenant Improvement / Alteration Permit Application
Application and plans must be complete In order to be accepted for plan review.
Applications will not be accepted through the mail or facsimile.
APPLICANT REQUEST FOR PUBLIC WORKS.SITE/CIVIL PLAN REVIEW OF THE FOLLOWING:
Additional reviews ma be determined b the Public Works De • artment
❑ Channelization/Striping ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling
❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation
❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public
❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public
❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only
❑ Water Meter /Permanent # Size(s):
Cl Water Meter Temp # Size(s): Est. quantity: gal Schedule:
❑ Miscellaneous
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and
is subject to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is Issued within 180 days following the date of application shall expire by
limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by
the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
Date application accepted:
- act
CTPERMIT.DOC 7/9/96
Date application expires:
a -a<c)
Application takpp.¢y: (Initials)
BUILDING OWN O A THORIZED NT:
Signature: 7/ Y 7 i 71,/ �
Date: rpf gb
f
Print name `�
ee k ,
Phone:
Fix #:
Address
City/State/Zip
92:11 A3
ALL COMMERCIAUMULTI -F ILY TENANT IMPROVEMENT /A RATION PERMIT APPLICATIONS
Mi BE SUBMITTED WITH THE FOL OWING:
ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT,
STRUCTURAL ENGINEER OR CIVIL ENGINEER
• ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN
• BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED
N/A SUBMITTED
❑ ,r7§i Complete Legal Description
❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures
(Form H -13). Business Declaration required (Form H -10).
Five (5) sets of working drawings, which include :
❑ )24 Site Plan (including existing fire hydrant location(s)
1. North arrow and scale
2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements
3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions
4. Location of driveways, parking, loading & service areas
5. Recycle collection location and area calculations (change of use only)
6. Location and screening of outdoor storage (change of use only)
7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's
boundaries
8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of
use only)
9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of
those, identify by size and species which are to be removed and saved
10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change
of use only)
11. Location and gross floor area of existing structure with dimensions and setback
12. Lowest finished floor elevation (if in flood control zone)
13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H-
9).
Floor plan: show location of tenant space with proposed use of each room labeled
Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of
any hazardous materials; dimensions of proposed tenant space.
Vicinity Map showing location of site
Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack
layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of
rack. Structural calculations are required for rack storage eight feet and over.
❑
21
Indicate proposed construction of tenant space or addition and walls being demolished
Construction details
Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of
water supply to sprinkler vault with documentation from contractor stating supply line will meet or
exceed sprinkler system design criteria as identified by the Fire Department.
Washington State Non - Residential Energy Code Date shall be noted on the construction drawings.
SEPA Checklist - if intensification of use (check with Planning Department for thresholds).
Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other
land use or SEPA decisions.
Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County
Department of Public Health prior to submitting for building permit application. The Department of
Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5)
Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no
contractor has been selected at time of application a copy of this license will be required before the
permit is issued OR submit Form H -4, "Affidavit in Lieu of Certificate of Contractor ".
Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed
by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and
obtain the permit will be required as part of this submittal
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
CTPERMIT.DOC 7/9/96
.nc.: Via '*"1 ; t s et ^ " 4; ;: { i�¢
City of Tukwila
Fire Department
Project Name Prior /44o--'4 Cc
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre -Fire:
Permits:
T KWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Retain current inspection schedule
X Needs shift inspection
X Approved without correction notice
Approved with correction notice issued
FINALAPP.FRM T.F.D. Form F.P. 85
John W. Rants, Mayor
Thomas P. Keefe, R re Chief
Permit No. &14-.00.1- a- v
Address 6,000 C1)r,s /r'hJrh Rrl Suite #
C.& -vu i! D /0
Authorized Signature Date
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575 - 4439
•
Permit No: l396•-
, Parcel No: 2523
Site Address: 1600
T h i s Pecvmerit
02b2 Type:
04••9(1/7
0 CHRIGTENSE
519.71 To
g **stf. * ** *•t ** *• 41 ***o1*Ati* *•**A* *•ti•k**
Account Code Description
000/322.1.00 BUILDING - NUNRES
000345.830 PLAN CHECK NONR1;S
000/3£16.904 STATE BUILDING SURCHARGE
it A****** 4A4 k* fr*** k/.* 4* *4•*•t4#•A***4*** * **:4****.4 kk.4** ti*. *****
:;ITY OF TUK.WILA. WO �rn -t (n TI:ti•r•'sril.)
4 *•4 * *•.t• *t*4**t ***4 ***i k * W* * r"�F k :1.h*k•4••14.IA* A• 4 r*• 4 ** .1 :1
TRANSMIT Number: 89600472 Amournt: 519.71 08/29/% 11:2:'
Payment Method: CHECK Notation: RIVERV.XEW PLAZA :trait: SLI3
13•-BUILD BUILDING PERMIT
N RD
Total Fees t V419.71
tal ALL Pmts: 519.71
B a l ance t .00
*A *AA 4, **:1 *** * * * * *A4A.4* * * * *•h*
Amount
L, 25
;31 �,
202,96
4.50
',:2680 9617 TOTAL ; 519.71
Projects -,, i jorn G ` ( ,
Type of inspec on ` A / }
j
r ac ze r s ) .6 .0z15Temsrk .b
IL
Date called:
Special instructions:
L.A.T.e_ P: :...._. ir a �-
FIN1 : ' 16 ?L C)
f %P .A
1
Date wanted -96 a
Requester:G J✓
Phone No.:
r �24 V ' g
�l
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 9818
Approved per applicable codes.
COMMENTS:
Inspector:
INSPECTION RECORD
Retain a copy with permit
�D - ' 2 -
PERMIT NO.
Date: Ja J ") ,.- .
20•> 431 - 3670
Corrections required prior to approval.
1
$42.0 REINSPECTIO FEE R OUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
...,.. 5....Tr.. ...:zu d,7Cc -.�F e.WC:
Proj t: R
�O� - /MA :ice --U
Type of inspectio :
fALS
1L) M7
Address:
I PI N P-6
Date called:
!d 2 1- To
Specci�ialliJins ructions:
L 1 2- STe 310
Date want e fd:^^
W
�7
- �!
a. .
Requester:
Phone No.: s21.
_ ` G 0 4
•
INSPECTION RECORD
Retain a copy with permit
INSPECT I• NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 9818
PERMIT NO.
(206) 431 -3670
COMMENTS:
:4
Inspector: ' 1%,*
Date:
I (if
q&
Approved per applicable codes.
Corrections required prior to approval.
$42.00 E INSPECTION FEE REQUIRED. Prior to inspect on, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
1
Proje ., 1O � / A. n � � I
Type of inspection +nM i N67
d o c' IiJ1Zjc 5& izb
Date called: (0.. Ig !
Special instructions:
731- Z - S - - a lv
f
Date wanted: g
10 -2.1 -c1 iD
Requester: ; y I/ e
Phone No.: 524 - r _U gLi
l
Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
LI
% tB0 -O2(oZ
PERMIT NO.
(206) 431 -3670
COMMENTS:
C ._,,., 0t X.. s-6-
Corrections required prior to approval.
Date: it)/7.(14(.(
Ti $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
ReceiprNo.:
Date:
Projec •
RiOg A arid
Typt ins ) fai
DIP l e called: 10 _ 1 to _ 91
Date wanted:
10 . II &n....
A fi 0 arl Fib
pedal ins
C_SIE -31 c.
Requester: sm v . c...
Phone No.: z4 laci_i
I I
INSPECTION NO.
•■•■•■•■■•*.o.■••■■■■•••••■••■.........
INSPECTION RECORD
'Z- Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 9818
Approved per applicable codes.
1396-Ozloz
PERMIT NO.
(206) 431-3670
COMMENTS:
A
\ .
Inspector:
Date:
/))/7/
Corrections required prior to approval.
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
COMMENTS:
I
Al .E1.19.9 cjF Ilc (N 1 Gb v■ 0 C1- (,49LL 1 (2.AA 0
Date called: 1 is _5
...
(6-Z114 SPA OS (A v° "TO SW-AA C.TAM , / r rCi ,
Special instructions:
'fli)1 6
- 1 . 10 f:
7--)
Apt> wAu.. 6(LA-OT 11 LA Ki-SLA`er0 sUM VA Y■J
N /A-LL. 1 t•) O'Clia-IL- a.{11..)1'r■
atc– -4D cvs... —,...„: ...:..
- ,• ‘,.,.
.::
r\
Pn WID IAAAg-real
Type of inspection AA li do
Al Pb
Mtbb eAlg-5A6C
Date called: 1 is _5
Special instructions:
'fli)1 6
Date wanted: _ I / 6' f,,,
1 w
a.
p.m.
Requester:
v &-
Phone No.: S2 J-4 - tagtii
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
C L \ ' 1
(206) 431-3670
Approved per applicable codes. ,Corrections required prior to approval.
Inspector:
Date:
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
. • "
Date:
ea• 1kI.j _42,2
';*" -
Dear Sir:
City of Tukwila
Fire Department Review
Control #B96 -0262
(510)
:::: tS1 N±>„+;;,,,, ....�..:G't�... ;n1.1? Epp .. .�Y . .zv^Cuf� . m5".�(+: J;.r HN7''w.x {
... .....Y . ....� .... ... ...'., .•r.. . .. ... 'NT+' art. eW,-" tCtt� »!�✓:"Uti'iiK' + +'"'(:.kC^ ^:•acs..; a.tc.
Fire Department Thomas P. Keefe, Fire Chief
September 9, 1996
Re: Prior Martech - 16000 Christensen Road, Suite #310
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. The total number of fire extinguishers required for
your establishment is calculated at one extinguisher for
each 3000 sq. ft. of area. The extinguisher(s) should be
of the "All Purpose" (2A, 10B:C) dry chemical type. Travel
distance to any fire extinguisher must be 75' or less.
(NFPA 10, 3 -1.1)
Extinguishers shall be installed on the hangers or in
the brackets supplied, mounted in cabinets, or set on
shelves (NFPA 10, 1 -6.9), and shall be installed so
that the top of the extinguisher is not more than 5
feet above the floor. (NFPA 10, 1 -6.9)
Extinguishers shall be located so as to be in plain
view (if at all possible), or if not in plain view,
they shall be identified with a sign stating, "Fire
Extinguisher ", with an arrow pointing to the unit.
(NFPA 10, 1 -6.3) (UFC Standard 10 -1)
Fire extinguishers require monthly and yearly
inspections. They must have a tag or label securely
attached that indicates the month and year that the
inspection was performed and shall identify the
company or person performing the service. (NFPA 10,
4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and
halon type fire extinguishers shall be emptied and
subjected to the applicable recharge procedures. (NFPA
10, 4 -4.1) If the required monthly and yearly
John W. Rants, Mayor
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 • Fax (206) 575.44139
City of Tukwila
Fire Department
Page number 2
The color and design of lettering, arrows and other
symbols on exit signs shall be in high contrast with
their background. Words on the sign shall be block
letters 6 inches in height with a stroke of not less
than 3/4 inch. (UBC 1013.2)
When two or more exits from a story are required and
when two or more exits from a room or an area are
required by U.B.C. Section 3303, exit signs shall be
illuminated. (UBC 1013.3)
inspections of the fire extinguisher(s) are not
accomplished or the inspection tag is not completed, a
reputable fire extinguisher service company will be
required to conduct these required surveys. (NFPA
10A -4 -4)
2. No point in a sprinklered building may be more than
200 feet from an exit, measured along the path of travel.
(UBC 1003.4)
3. Exit doors shall be openable from the inside without
the use of a key or any special knowledge or effort. Exit
doors shall not be locked, chained, bolted, barred, latched
or otherwise rendered unusable. All locking devices shall
be of an approved type. (UFC 1207.3)
4. All new sprinkler systems and all modifications to
existing sprinkler systems shall have fire department
review and approval of drawings prior to installation or
modification. New sprinkler systems and all modifications
to sprinkler systems involving more than 50 heads shall
have the written approval of the W.S.R.B., Factory Mutual,
Industrial Risk Insurers, Kemper or any other
representative designated and /or recognized by The City of
Tukwila, prior to submittal to the Tukwila Fire Prevention
Bureau. No sprinkler work shall commence without approved
drawings. (City Ordinance #1742)
All sprinkler system plans, calculations and the
contractors Materials and Test Certificates submitted
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 -4404 • Fax (206) 57544139
^.5" eve: rU: fY. �l���; r!.r df i'N.`JMf�°!Ct.27ti7.`_;p X114 M iir*?,711 >.! ASSN :Avgri anti. 7fR!.kmrfA?,:Ant ar ariallG "I 11" IV?.'r
City of Tukwila
Fire Department Thomas P. Keefe, Fire Chief
Page number 3
to The Tukwila Fire Prevention Bureau must be stamped
with the appropriate level of competency seal. (WAC
212 -80)
Maintain sprinkler coverage per N.F.P.A. 13.
Addition /relocation of walls, closets or partitions
may require relocating and /or adding sprinkler heads.
5. An aisle to and working space shall be provided for
each electrical panel. An aisle width not less than 24
inches shall provide access to the panel and 30 inches of
working space shall be provided directly in front of the
panel. (NEC 110- 16(a), NEC 110- 16(c))
All electrical work and equipment shall conform
strictly to the standards of The National Electrical
Code. (NFPA 70)
6. Accumulation of combustible waste material is
prohibited during the demolition phase of this project.
Remove and properly dispose of all waste material prior to
the close of the working day and as often throughout the
day as needed.
7. In order to provide you with the fastest police and
fire protection under emergency conditions, please post
your suite, room or apartment number in a conspicuous place
near the main entry door. Numbers shall contrast with
their background. (UFC 901.4.4)
Any overlooked hazardous condition and /or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
John W. Rants, Mayor
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Plane: (206) 575.4404 • Fax (206) 5754439
•
Page number 4
Yours truly,
cc: TFD file
ncd
City of Tukwila
Fire Department
The Tukwila Fire Prevention Bureau
John W. Rants, Mayor
Thomas P. Keefe, Rre Chief
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 Fax (206) 5754439
September 3, 1996
Mr. Chuck Mahlum
16000 Christensen Road, Suite #101
Tukwila, Washington 98188
Dear Mr. Mahlum:
City of Tukwila
Department of Community Development Steve Lancaster, Director
SUBJECT: Development Permit Application Number B96 -0262
Prior/Martech •
16000 Christensen Rd, Suite #310
FILE COPY
John W. Rants, Mayor
This letter is to inform you that your permit application received at the City of Tukwila
Permit Center on August 29, 1996, was reviewed at the September 3, 1996, plan review
meeting. Your application was determined to be complete. Your permit has begun the
plan review process, you will be notified of any corrections or when your plan is
approved.
If you have any concerns or questions please contact me at the City of Tukwila Permit
Center at (206) 431 -3672.
Sincerely,
ee GC1Z derC5a
Kelcie J. Peterson
Permit Coordinator
File: ` B96 =0262
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 413/3665
02/22/96 10t38 a 206
6901
Matrix Company
• .nt- .. n.� .,.�.�.w��+�l....*.+.MOtee .... oaPw Paires ,.,..... ...... ...........:. ,,,,,.«,..,..., ... ...,a_•...s..�..,.5.: ..
1L4 • SrJ!?]T.YM:iii°' • • li .S]C4 .�_ :.. SLl.Y!+ .. •fir
t F �
:ti 3NT r • CEN$RAIk,•• .. `• .�, •• •.•• :f�
•
J•.,._ ... • -. - 71b11N[WtRw�:.... ' _ .. _ ....t9UiM? afAtt ; �,
DEPARTMENT OF LABOR AND INDUSTRIES
THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PI'IOVIDED BY LAW AS A
STATC OP WASHINGTON
ANN CtR'K. i_ V!0R7ii. l.arLw.Cii[�CAV .v»wv.+ .,= 4 71. • .. .•,...... M� •.. ,.v.r++.+ ... .........� tJ
• .'tea". ----- :?.Ireww 3Y!!`•�` �, S,,.t++L. ��..
... �o.o•.a. 090 :3.92i
Si •
P.01
RECEIVED
CITY OF TUKWILA
AUG 291996
PERMIT CENTER
GENERAL NOTES
a ALL DEBRIS SHALL SE REAOVM PROM ALE PREMISES AND ALL AREAS SHALL BE
LEFT W A CLEAN (BROOM) C AT AIL TIMEX.
5 ApPROvED PLANS SHALL KETT M A PLAN SOX AND SMALL NOT BE LMT r ANY
WORKMEN ALL CONETRUC11011 SETS BIBILL REFLECT THE SAME O ATIO S
� NAP/TALE INTER � COIWFTP I. OR TE OF PL WFn1 ALL CONT
REVNNONS, A NOA. NIA OILANB! � 5 AT ALL TRIPS WNg0
ARE TO BE LINGER THE CARE OF RAE JOB EUPBRE TEN
■ ALL OPERA TIOIIS CCHIOUCTE0 ON THE PREMISES SHALL 1407 BE ORNICTIONABLE
BEYOND THE PROPERTY BOLN/OAPT UMW BY REASON OF NOISE. ODO
FUMES GASES, SMOKE VIBRATION, HAZZIPO OF OTHER CAUTSpENS� IN ADC/TOR THE
cONTTGCTOR SHALL COOT, RRIDOR FUMES. M
VRA LL 1_ TPON. A COMMON Y ARO DORMD0R SPACE
SHALL BE KEPT CLEAR OF DUST, DEERS, AND WNSTRUCTI ON MATERIALS AT ALL
TIMES
7 ALL WORK SHALL BE APPLIED */ ATSC WITH THE MNIINACTURERe LAAES T
RECOMMENDATIONS OA WRITTEN
9 ALL DMENSIONB ARE TO FACE OE JIACAI WA . P00W UHGESS OMERRISE 5 0TEG
p wHE RE CCNBTIYICTION METRES ARE NOT SHOWN OA NOIT® FOR ANY PART OF THE
WORK TEE DETAILS SHALL BE THE SAME AS FOR OTHER BB40A11 WORK IA THE NAME
KELP.
WHERE DEVICES OR rums on PARTS THEREOF ARE REFERRED to IN
SINGULAR IT IS INTENDED THAT SUCH1 BNNL APPLY TO AS WANT SUCH DEVICES
ITEMS OR PARTS AS ARE TIEOIMMD TO LE COMPLETE THE WORK.
11 R SHALL BE THE 5EBPONBIMUTY OF THE CONTRACTOR TO LOCATE ALI METING
UTIUTES W'IRTNER MEMO APRON 00 NOT A RO TO PROTECT TEEM FROM DAMAGE
THE CONTRACTOR SHOAL SEAR ALL EXPQME OP REFER OR REPLACEMENT OF
071UTES OR OTHER PROPERTY DAYAGM EY OPERATIONS IN COT/RICTOH WITH THE
(EXECUTION OF MS WORK.
12 THE CONTRACTOR WILL AIMEE AND WMFORTS TO ALL REOSAPEMEN TS OF ALL
UTILITY COMPRESS LNAE'SS DTNERWTSE NOTED N THE PLANS AND SPECIFICATIONS
CORAL. WITH THE OPA 4JNIFORM BUILDING
TA TE REODUT ION FOR BARRIER FREE DESIGN ANS WITH t.SABi
T WASHINGTON STATE ENERGY CODE. STANDARDS
IM PLUMBING A
CODE. ANC. ALL
AC AL SMILE LOCAL CODES ORpNANCES, ARO STANDARDS
CONTRACTOR 19 TO VERIFY ALL EXIST/NO COW:MONS, DIMENEION6, DETAILS, TIC
AND NOTIFY 75I! OESKINEP OF ANY AND ALL DMCREPANCIB9 PRIOR TO PROLE
FONG WITH rHE WORN.
CONTRACTOR SHALL VERIFY ALL •MILWNO BTMIOAROB' YATH BUILDING LANDLORD
PRIOR TO BEGINNING ANY WORN HO WERSA . THERE MALL SE NO DEVIATKXIB .
WHATSOEVEP FROM THE CON TRN'T DDCUME 9 RET/BllfT THE DEE M EWS WHIT.
TEN APPROVAL THEREOF TIE CORTEACTON AGREES TO DEFEND, EI0EMMEY. AND
HOLD THE Dew Kinen HARMLESS FROM ARV CLAIMS ARISING AR A net/LALT Cf
UNAPPROVED CHMIOS
THE CONTRACTOR SHALL TAXE ALL SAFETY OF THE OCCUPANTS AND W0455! AT L, TI TO ENSURE
MITIONE TEE
14 THE DONTRACT. SHALL BE RESPONSIBLE THE COMPLETE SECURITY OF THE
911ADOM AND SITE WERE JOB IS IN PROGREY UNTIE THE JOS IS COMPLETED
IS Au. W(IRK SHALL SE IINARANTEEO FOR A PERIOD OE ONE 1) YEAR AFTER SE 50 STATED 111
CONTRACTORS FRIES PROPOSAL ATE) AGREEMENT LL iLL REPMRB WRREC tIONS.
AND DISCREPANCIES, ETC., TI
UST RE MADE WITHOUT ANY ADDITIONAL COST TO TEE
OWNER, AND WITH M
IN
FIVE S GAYS AF TE R NOTKYa 19 OMEN.
19 LATHING, PLASTER. MID GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO •TIE
CHAPTER AT OF THE HESS U.S.C.
I , Al). EXPOSED GYPSUM BOM1D TO HAVE METAL EDGES AT ALL CORNERS AND WALL
INTERSECTIONS
I S ALL GLASS AND I4LCZIN0 9R ALL COMPLY WITH CHAPTER 54 OF THE 18810.5 C AND
Tie U B PRODUCT SAFETY COMMISSION: SAFETY STANDARD FOR ARCHITECTURAL
GLAZING MATERIALS
I9 ALL REQUIRED FIRE ODORS SHOAL SEAR A LABEL RIOT A RECOGNIZED AGENCY
SHOWING THE SPECIFIC PANES.
EXIT SIGNS AND ILLUMPATKON MALI CONFORM TO 714E ISM U S.C. CHAPTER YI,
AND LOCAL FIRE MARSHAL MEOWED/1E5T5
Al EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT TIE USE OF A KEY OR
ANY SPECIAL KNOWLEDGE OR EFFORT
22 FIRE EXnNOUISNERS VERIFY RODUMEMENTS ANp LOCATIONS WITH FIRE MARSHAL.
CONTRACTOR TO SUPPLY FIRE EXTINGUISHERS ERS AND CABINET AS REOIIIRED.
22 . ELECTRICAL ROLXM4'114 AND REFLECTED CEUNO PLAN ARE FOR THE GENERAL
FORMATION Of ME CONTRACTOR. EXACT LOCATIONS SHOULD NE VERIFIED
24 FLAMMABLE LAOTIAN SMALL NOT SE PLACED, STORED, OR DMFENSED IN THIS
OCCUPANCY EXCEPT AS PROVIDED M NT? A STANDARD SD AND THE Cl1MENT
UNIFORM FIRE COTE PERMIT MAYBE
NBREQUIRED. Aµ DECORATIVE
25 AU. ETlRIAALS
L, INCLUDING Q Tiles THAT wow TE TO INCREASE TIE ME
AND PANIC HAZARD SNAIL SE MADE FROM NOSLFIAMAELE MATEISAI, OR SHALL BE
TREATED AND MAINTAINED M AFIRE WAWA co/AMIGA BY MEANS OF A RAMS
RETARDANT SOLUTION OR PROCESS APPROVED ST THE CdNITT FIRE MARSHAL
PROVIDE A CERTIFICATION To This OPBCT.
A. EXIT DOORS, our 00510, NAG FEW EXTTNIMAMIER'LOCATIONS SHALL NOT BE
CONCEALED OR 08511117 MY ANY DECdUTII MA MERAL
B. MBIMNN FLAME sAwApCLASSIFICATION CFSETMIIOR FINISHERS SHALL BE
PER TABLE AE - B Of THE TSAR U.S.0
AS ALLAV.IM AOW9TICALCMlJ11O GRIPS SMALL EARTHFNM SE INSEAQ,EW f ZD ONE A SECURED PER 1111
U.B.C. SECTION 4'104, STMFI11FC 4]•18. POR MC M .
TT PROVIDE OR MODIEY ASH O µA111 MID SMOKE MECH.
STSTEE PEI ALL N OTROL E E IVMCLM�� 5QII S IE /ID MIB.
ALARMI LIGHTS, SHOP dUWNNBS TO SM.ArRIMO11KZ1 M��ID VISUAL 2e TO t PROYOS N101NeTµL DM MRO2 OTHER S
19. MECHANICAL MEgMAO w � L u " ° -
SIG, ANY SMEENI
SlI.UREORTgH.
a0 PROYIOE OR MOOIFY AS NEEDED EIMENENLV LOWING
Al ALL ITEMS MARKED' NEC. • ARE NOT PART OF TENS ®ATRACT.
$ ASMIEVMTIDNB TAMNS_SIIpJT T(o MANs ARK • •.'1��'. 1 ARE IN
COMMON DA THE SETIT A IN E D V C IOMO
THE P RO E THE T HE DR
N N E R WIIL D E dd FI 1 N I TH E INTENT O F ANY N QU v uBEO oN
GL
G.w.B
HD WO
HT
H.W.
INC
IN CE
INTR
Jr
JT
LAM
LTG
LT
ABBREVIATIONS
FCUUS
ACT
ADJ
A P.
APED
ARCH
ELK
BLDG
CL ORC
CLKO.
COL.
CORS.
C
ONTR
CPT
cyf
SETT
ELT.
DIAO
ONE
D
ELEV
ELEC
4 0
OPT
F XIST
0
FIN
FL
FOIL
SITE PLAN
ACOUSTIC ACOUS IICAL
ACOUSTICAL TILE
ADJUSTABLE. ADJUST
ACCESS PANEL
APPROVED
ARCHITECTURAL
BLOCK' BLOC%1N0
BUILDING
CENTER LINE
CAULKING
COLUMN
CONTRETE
CONSTRUCTION
CONTRACTOR
CARPET
0010 WATER
DEPARTMENT
DETAIL
A GAL
DIAMETER
DIMENSION
DRAWING
ELEVATTOR(SLDO■ '
ELEVATOR
ELECTRICAL
MET
MAY
LIED
MFR
MIN
MISC
MTD
MTL
NIC
NTS
OC
PT
PARE
PPL
PL
PIAM
PLY
T
RE
R
REF
RECD
REV
R
SECT
SHT
EQUIPMENT SIM
EXISTING SPE, .
FURNISHED E INSTALLED SST
BY OTHER STD
FINISH STOR
FLOOR STRUC
ANSI D BY OTHER SUSP
INSTALLED BY SW
CONTRACTOR TEL
GLASS: GLAZING' GLAZED TEMP
GYPSUM WALL BOARD TIP
HARDWOOD VAR.
HEIGHT V.0 T
HOT WATER VERT
INCANDESCENT V.P
I NT TE E l R 1 IION S W.C C.
JOINT WD.
LAMINATED' LAMINATE WT
LKNITOSO
LNJ11T
MATERIAL
MAXIMUM
MANUFACTURED
MANIA-AC [ COCA
MINIMUM
MISCELLANEOUS
MOUNTED
METAL
NOT III CONTRACT
NOT TO SCAT E
N CENTER
PAINT
PARTITION
POLISHED PLATE GLASS
PLATE
PLASTIC LAMINATE
PLYWOOD
QUARRY TILE
BUSSES BANE
REFERENCE
REQUIRED
REVISED REVISION
ROUG OPENING
STAIR
SECTION
SHEET
SIMILAR
SPECIFICATIONS SPECIE I
STAINLESS STEEL
STANDARD
STORAGE
STRUCTURAL
SUSPEND' SUSPENDED
SWITCH
TELEPHONE
TEMPERED
TYPICAL
VARIABLE VARIES
VINYL COMPOSITION ILE
VERTICAL'. VERTICALLY
VENEER PLASTIC
WOOD BASE
WATER COVERING
WOOD
WEIGHT
CO TRACT THIS AREA
Ti - COVER SHEET
A -1 DEMOLITION /PARTITION /ELECTRICAL /TELEPHO, E/
REFLECTED CEILING PLAN
aP tea. r` ✓aru- �.
PROJECT ADDRESS.
GOVERNING CODE.
USE ZONL'
OCCUPANCY.
CONSTRUCTION TYPE.
ENERGY CODE.
PLUMBING CODE:
CONTRACTOR
MECHANICAL
ELECTRICAL.
SPRINKLER SYSTEM.
TENANT AREA.
LEGAL DESCRIPTION
PROJECT DATA
16300 CHRISTENSEN ROAD. TUKWILA WA 98188
SUITE #310
1994 U. BC (STATE OF WASHINGTON AMENDMENTS)
1991 WASHINGTON STATE ENERGY CODE ,
O93 U.P.C.
TO BE DETERMINED PRIOR TO PERMIT ISSUANCE
BIDDER DESIGN (UNDER SEPARATE PERMIT)
BIDDER DESIGN (UNDER SEPARATE PERMIT)
BIDDER DESIGN (UNDER SEPARATE PERMIT)
1,502 S.F.
VICINITY MAP
understan 1041 the PIan Check apPIDY IO
ns VSI
T G1
1 I zcl toarrors and OINEID Old lOPr nI BIIY
-. 5 DOES n01 "1' I COn'
),vied cOdS 01 U
- ,Nl CAT'
OR's COOT OI
By
P P 0`J E 0
SE? 16 1996
2I w1 IsoN
fib -oab�
R DELVED
clTV of TUKWILA
AUG 2 9 1996
PERMIT CENTER
connell
design
group
PLANNIN(I & L)1' SIGH
CDG
22000 64TH AVENUE WEST. #2E
REVISIONS
B RAL1EP FOP PERMIT
TITL
COVER SHEET
96205
SHEET
T -1
EXISTING
OFFICE
304
DEMOLITION/PARTITION PLAN
SCALE: I /8" x 1' -C'
DEMOLITION NOTES
EXISTING
OFFICE
DEMOLITION OCCURS, ALL REMAINING WALLS ARE TO BE PATCHED, SANDED
SMOOTH AND PREPARED FOR FINISHING AS REQUIRED. PATCH AND PREPARE
FLOORS AS REQUIRED FOR SMOOTH, LEVEL FINISH.
ALL EXISTING WALL FINISHES TO BE REMOVED. WALLS ARE TO BE PATCHED,
SANDED SMOOTH AND PREPARED FOR NEW FINISHES AS REQUIRED.
WHERE NEW PARTITION MEETS EXISTING FURRED COLUMN OR CORE WALL REMOVE
CORNER BEAD, ALIGN. TAPE AND SPACKLE NEW PARTITION TO EXISTING GYPSUM
BOARD.
ALL CONSTRUCTION TO REMAIN AND AFFECTED BY DEMOLITION SHALL BE PATCHED
AND SPACKLED AND BE PROPERLY MEMBERED AND ALIGNED SO AS TO LEAVE NO
EVIDENCE OF PATCHING OR REPAIRS.
EXISTING ELECTRICAL AND TELEPHONE OUTLETS LOCATED ON DEMOLISHED WALLS
ARE TO BE REMOVED INCLUDING CONDUIT AND WIRING BACK TO JUNCTION BOX.
WHERE PLUMBING FIXTURES ARE BEING REMOVED OR WHERE EXPOSED PLUMBING
PIPES OCCUR. CAP LINES BEHIND FINISHED SURFACES.
ALL EXISTING CONSTRUCTION WHERE INDICATED INCLUDING ELECTRICAL,
TELEPHONE. PLUMBING AND MECHANICAL DEVICES NOT OTHERWISE INDICATED ON
THESE CONSTRUCTION DRAWINGS SHALL BE REMOVED IN A CAREFUL MANNER SO
AS NOT TO DAMAGE ADJOINING CONSTRUCTION.
PARTITION NOTES
ALL PARTITIONS. UNLESS OTHERWISE NOTED. SHALL BE CONSTRLICTED WITH
METAL STUDS AT 24' O.C. WITH 5/BN TYPE 'X GYPSUM WALLBOARD EACH SIDE.
THERE SHALL SE NO EXPOSED PIPE, CONDUIT, DUCTS, VENTS. ETC. ALL SUCH LINES
SHALL BE CONCEALED OR FURRED AND FINISHED. UNLESS OTHERWISE NOTED AS
EXPOSED CONSTRUCTION ON DRAWINGS.
OFFSET STUDS, WHERE REQUIRED, SO THAT FINISHED PARTITION SURFACE WILL BE
FLUSH, UNLESS OTHERWISE NOTED. PROVIDE FURRING AT EXISTING PARTITIONS AS
REQUIRED TO INSTALL ELECTRICAL ITEMS AS INDICATED ON THE DRAWINGS.
DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS ARE TO BE SIX INCHES
FROM FACE AT HINGE SIDE OF DOOR TO ADJACENT PARTITION.
ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT USE OF KEY OR ANY
SPECIAL KNOWLEDGE OR EFFORT.
PROVIDE SHEET METAL REINFORCING (S" HORIZONTALLY MOUNTED STRIP OF 20 GA.
GALVANIZED SHEET METAL) IN PARTITIONS FOR INSTALLATION OF WALL HUNG CABINET
WORK AND PANELING WHERE INDICATED ON DRAWINGS INCLUDING ALL OWNER PROVIDED
ITEMS.
CONTRACTOR TO VERIFY DIMENSIONS FOR ALL PLUMBING PARTITIONS.
CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DESIGNER APPROVAL PRIOR TO
MANUFACTURE OF ANY CABINET WORK, MILLWORK, AND ANY OTHER SPECIAL ITEMS
REQUIRING CUSTOM SHOP FABRICATED WORK
PARTITION LEGEND
_ - = DEMOLITION
EXISTING PARTITION TO REMAIN
■ B/S TENANT PARTITION - B/S METAL STUDS @ 24 "O.C. WITH 5/8' TYPE X' GWB
ON BOTH SIDES FROM FLOOR TO UNDER SIDE OF HUNG CEILING
BIS LOW HEIGHT PARTITION . •3' -6"A. F. F. x MIN. DIM THICK
B/S PARTIAL HEIGHT RELITE - SILL @ +3' -4'U x WIDTH TO MATCH EXISTING
RELITE x HT TO ALIGN WITH DOOR HT
DOOR SCHEDULE
Tr /- -DOOR NUMBER
YPE OF DOOR
e'uNLESs
N
A B/S 3' - 0' x B/S HEIGHT DOOR IN B/S FRAME
B RELOCATED DOOR AND HARDWARE
E EXISTING TO REMAIN
EXISTING
OFFICE
EXISTING
OFFICE
307
— HARDWARE
a S'S LATCHSET
NOTE: CONTRACTOR TO REUSE AND RELOCATE EXISTING DOORS AND
HARDWARE WHERE POSSIBLE
ALL NEW HARDWARE TO BE LEVER STYLE
CONFERENCE
EXISTING
OFFICE
ELECTRICAL /TELEPHONE PLAN
SCALE I /S' =
ELECTRICAL NOTES
ALL WALL MOUNTED TELEPHONE AND ELECTRICAL OUTLETS TO BE INSTALLED 15'
ABOVE FLOOR UNLESS OTHERWISE NOTED
ALL CORE DRILL LOCATIONS SHALL BE VERIFIED WITH DESIGNER PRIOR TO DRILLING
ALL UNUSED CORE DRILLS SHALL BE PLUGGED AND CAPPED AS REQUIRED TO
MAINTAIN FLOOR FIRE RATING
ALL TELEPHONE AND COMPUTER WIRES SHALL BE PULLED BY TENANT
CONTRACTOR UNLESS OTHERWISE NOTED. ELECTRICAL CONTRACTOR SHALL
PROVIDE FULL WIRES AND BOXES AT EACH LOCATION
ELECTRICAL LEGEND
4
Q
4
mil
2.3
DUPLEX RECEPTACLE OUTLET
FLOOR MOUNTED ELECTRICAL OUTLET
FOURPLEX RECEPTACLE OUTLET
WALL MOUNTED TELEPHONE OUTLET
DEDICATED TELEPHONE LINE
WALL MOUNTED COMBINATION TELEPHONE /CRT CABLE
WALL MOUNTED CRT CABLE RECEPTACLE OUTLET
INDICATES QUANTITY
NEW
CAP EXISTING OUTLET AERIFY WITH TENANT
MODEM
RETROFIT EXISTING OUTLET VERIFY WITH TENANT
NOTE: CONTRACTOR TO REUSE EXISTING ELECTRICAL / TELEPHONE OUTLETS
WHERE POSSIBLE
KEYNOTES
EXISTING
OFFICE
OFFICE
EXISTING
ALL OUTLETS SHOWN ARE EXISTING EXCEPT WHERE NOTED ON PLAN
1 ALIGN FINISHED SURFACES
2. ALIGN @ CORNER
3 TENANT PROVIDED UNDERCOUNTER REFRIGERATOR 2' -0' w x 2'.1 1/2" Op
x 2' -10 1/4" h
4 EXISTING COAT ROD AND HAT SHELF TO REMAIN
5. EXISTING PHONE BOARD TO REMAIN
6. EXISTING SINK, BASE AND UPPER CABINET TO REMAIN REMOVE EXISTING BASE
AND UPPER CABINET IN OFFICE Y307 . START NEW PARTITION PER KEYNOTE 10
1. EXISTING BASE AND UPPER CABINET TO REMAIN
8. PROVIDE B/S P -LAM RECEPTION DESK WITH 1' 'tlp x 3' -SNP-LAM TRANSACTION
SURFACE ABOVE AND 2' -5 "h P -LAM WORK SURFACE BELOW WITH KNEE
CUT OUT SUPPORTS BELOW AS NEEDED PROVIDE (2) 1 1 /2 "Oia
GROMMETS IN WORK SURFACE. VERIFY LOCATION OF GROMMETS WITH TENANT
PROVIDE (2) 3' x 3' FALSE GWB COLUMNS FOR ELECTRICAL SUPPLY AT EACH END
9. START NEW B/S TENANT PARTITION 2' - CLEAR FROM EXISTING UNDERCOUNTER
OPENING.
10 ALIGN RECEPTION DESK WITH EXISTING WOOD FLOORING
•qb -daba
EXISTING
OFFICE
fa)
3031
CONFERENCE
E
REFLECTED CEILING PLAN
SCALE= I /S' s F -
LIGHTING NOTES
PROVIDE FIRE DAMPERS AT ALL SUPPLY AND RETURN AIR OUTLETS, INLETS, OR
DUCTS PENETRATING FIRE RATED ASSEMBLIES, ENCLOSURES, WALLS, FLOORS, OR
SURFACES, AND AS REQUIRED BY FIRE DEPARTMENT.
CONTRACTOR SHALL OBTAIN APPROVAL FROM DESIGNER OF ALL THERMOSTAT
LOCATIONS.
ALL REQUIRED EXIT SIGNS SHALL HAVE LETTERS SIX INCHES HIGH MINIMUM AND
SHALL CONFORM WITH ALL APPLICABLE CODES.
CEILING HEIGHTS ARE FROM SLAB TO FINISHED CEILING.
LIGHT SWITCHES SHALL BE INSTALLED AT A.F.F. MULTIPLE SWITCHES SHOULD
BE GANGED TOGETHER UNLESS OTHERWISE SPECIFIED.
CONTRACTOR SHALL PROVIDE EMERGENCY LIGHTING, STROBE LIGHTS, AUDIO-
VISUAL ALARMS, TO MEET ALL APPLICABLE CODES.
LIGHTING LEGEND
OFFICE
EXISTING
EXISTING 5/5/2 x 4 FLUORESCENT LIGHT FIXTURE TO REMAIN
RELOCATED EXISTING 87S 2 x 4 FLUORESCENT LIGHT FIXTURE
lJ RELOCATED EXISTING DOWN LIGHT
Ez_/ EXISTING TRACK LIGHT TO REMAIN
ILLUMINATED EXIT SIGN - DIRECTION OF ARROW
y. - B/S SINGLE SWITCH
E EXIST /NG TO REMAIN
C CAP EXISTING SWITCH. VERIFY WITH TENANT
NOTE: CONTRACTOR TO REUSE AND /OR RELOCATE EXISTING LIGHT FIXTURES
AND SWITCHES WHERE POSSIBLE
CONTRACTOR TO RESWITCH/RECIRCUIT EXISTING LIGHT FIXTURES
AS NEEDED
LIGHTING CALCULATIONS
ALL EXISTING LIGHT FIXTURES TO REMAIN WITHIN TENANT SPACE NO PROPOSED
CHANGE IN ENERGY USAGE
SECTION BUILDING
" STANDARD PARTITION
SCALE. NTHI
01 R E C EIIDES
AUG 2 9 1996
PERMIT CENTER
CDG
connell
design
group
I'LANN EN( ; & DESIGN;
REVISIONS
96 ISSL1Fn FOR PERMIT
TITLE
DEMOLITION/PARTITION/
ELECTRICAL /TELEPHONE/
REFLECTED CEILING PLAN
96205
SHEET
980/1:3
A -1