Loading...
HomeMy WebLinkAboutPermit B96-0263 - BRUEGGERS BAGELS - BAKERY3 City of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: B96 -0263 Type: B -BUILD Category: ACOM Address: 361 STRANDER BL Location: Parcel 4: 262304 -9064 Zoning: Type Const: V -N Gas /Elec: Wetlands: W Water: N/A Contractor License No.: COMMESI184MK Status: ISSUED Issued: 10/07/1996 Expires: 04/05/1997 Type of Occupancy: RESTAURANT Slopes: N Sewer: N/A TENANT BRUEGGER'S BAGELS 361 STRANDER BL, TUKWILA, WA 98188 OWNER SPIEKER PROPERTIES 915 118 AV SE *110, BELLEVUE WA 98005 CONTACT NANCY LIM 10940 NE 33 PL *202, BELLEVUE WA 98004 CONTRACTOR COMMERCIAL STRUCTURES INC. P.O. BOX 68845, SEATTLE, WA 98168 Phone: 206 827 -2100 Phone: 206 246 -3939 ******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: TENANT IMPROVEMENT FROM RETAIL TO BAKERY. SETBACKS Units: 001 Front: .0 Back: .0 Buildings: 001 Left: .0 Right: .0 Fire Protection: SPRINKLERED UBC Edition: 1994 Valuation: 120,000.00 Total Permit Fee: 1,633.46 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** /Data Permit Center Authorized Signature Lo Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Signature: Print Name: _��-j A.\\--z Date: /'-7 —' Title: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA Address: 361 STRANDER BL Permit No: 896- 0263 Suite: Tenant: BRUEGGER'S BAGELS Status: ISSUED Type: B -BUILD Applied: 08:30/1996 Parcel #: 262304 -9064 Issued: 10/07/1996 ** * * * *'k *'k * * ****** ** ** ***** ** * *A k* **'k** *** ** * *** k *'k****** ******•k *** k* k * **** k Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and the Tukwila Building Division. 2. Plumbing permits shall :be obtained through the Seattle -King County Department..of Public Health. Plumbing will be inspected by that agency, including all gas piping (296 - 4722). 3. Electrical permits shall be 'obtained through the Washington'` State Division of Labor and Industries and all electrical work will be inspected by that agency 6630). � 4. All mechanical work shall be, under separate permit hissued;k�y the City of Tukwila. • 5. All permits, inspection records, and approved plans shall be avail "able at the. job s.i.teprior to the start of any con - struction: These documents are to be maintained and avail able:untii final inspection approval is granted. 6. Any new ling grid and Tight fixture installation is required to meet lateral,bracing requirements for Seismic Zone 3. 7. Partition.,walls attached to ceiling grid must be laterally braced it ; over eight (8) feet in, le.ngth.. 8. An exposed insulations backing material shall have a Flame Spread Rating of 25 or , l esS , and material shall bear i dent i f ication -show the fire performance rating thereof.. 9. All c ons t ruction to be done in conformance with approved p l ans arid. requirements of the . Un i f arm 8u it d i ng Code (1994 Edit.'iQn) es: amended, Uniform Mechanical Code (1994 Edition). and Washington State Energy Code (1994 Edition). 10. Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to.be a.permit for, or an approval of, any violation of any of.the provisions of, the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or' cancel the provision, of this code shall be valid. 11. There shall be no occupancy of the buildings) until the final inspection has been completed by the Tukwila Building Inspector. • 12. VENTILATION I'S REQUIRED FOR ALL ' NEW 'ROOMS AND SPACES OF NEW OR EXISTING BUILDINGS IN CONFORMANCE WITH THE UNIFORM BUILDING CODE AND THE WASHINGTON STATE 1 /ENTILATION AND INDOOR AIR QUALITY CODE, CHAPTER 51 -13 WAC. 4 ,City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 262304 -9064 Address: 361 STRANDER BL Suite No: Location: IN FOOD PREPARATION AREA Category: NRES Type: MISCPERM Zoning: Const Type: V -N Gas /Elec.: Units: 001 Setbacks: North: Water: N/A Wetlands: W Contractor Licence No: COMMESI184MK Permit Center Authorized Signature._ MISCELLANEOUS PERMIT Print Name: i� Permit No: Status: Issued: Expires: MI96 -0002 ISSUED 10/07/1996 04/05/1997 (206) 431 -3670 Occupancy: RESTAURANT UBC: 1994 Fire Protection: SPRINKLERED .0 South: .0 East: .0 West: .0 Sewer: N/A Slopes: N Streams: OCCUPANT BRUEGGERS BAGEL BAKERY 361 STRANDER BL, TUKWILA WA 98188 OWNER SPIEKER PROPERTIES LP 915 118TH AVE SE, BELLEVUE WA CONTACT KIRSTEN LOBISSER Phone: 206 828 -6899 10940 NE 33 PL #202, BELLEVUE WA 98004 CONTRACTOR COMMERCIAL STRUCTURES INC. Phone: 206 246 -3939 P.O. BOX 68845, SEATTLE, WA 98168 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALL 20 GALLON THERMACO GREASE INTERCEPTOR IN THE FOOD PREP AREA. ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Construction Valuation: $ .00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: JJS Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: Y No: 1 Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 24.50 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. Signature: ! �__! �...._...•���� Date — _ c This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Vi14 • • s : Address: 361 STRANDER BL • Suite: . Tenant: Type: MISCPERM • Parcel #: 262304-9064 • **************k****/.*****kh****kk*kkkAA***** Permit Conditions: 1. THE THERMACO BIG DIPPER MODEL #W-200-IS SHALL BE INSTALLED ACCORDING TO THE MANUF. RECOMMENDATIONS. ';'• ' 1) ':. 0 .'.).. ..- .. • .1 :!, 'i N. ..? '41 ..Q. , , it ''l . PP' ti 4,••• •:, r, e r tr;• 1 ''''"t',%. .:-.T. ti,•? ° V.::•: 1 -': ' , " ' , i'..• . 1 i,A 1 ■ ,X';• '' * • • , • "' !'"r; !• ! •••'•!;1 r • ' -Tr CITY OF TUKWILA ti . .•„, . ` • • .y • - ',... it, . . fr: f '..--.., ..„, `,,''••!;: ( ; ,,,,.. ‘,.,, ,0 : -,• kv . ‘ppe , ..?• /•-■,: .. ,........ . p • .. 4, ....., '' , . : • , .. .. .. ■ ,!,- 1 f I t ■.,,,,.;,-•;2i:! !''' -, ?Li • ''',, ip ' • •'■:`, • ATAMtSM970...011 Permit No: MI96-0002 Status: ISSUED Applied: 09/05/1996 Issued: 10/07/1996 *A* - . ; ,-; . •;;P , ":".-- . . . . ., .. i•, 1 -!... • ". -•" , 1. ::.„.•:,......, ..%. ,,. ....- • : r...... ::• 1 '-:•.! a! • Project Name/Tenant: , bRuE[ R 5 BAGEL 15FW-- elect' Value of Construction: /ab oco Site Address: City State /Zip: Pt FrFtn bN OF 6C6 srtefil3cet ElsW Ilklet,61 Tax Parcel Number. a(a 3o4 - gGYo4 - 03 Property Owner: lElt'..Fa2 PRopte->7Es Phone: 3- 1 4000 Street Address: 9 /S, 118" Ave se iii es Ci State/Zip: Fax #: Contact Person: 4sposi ,oes /vf3 /sSE Phone: gal 01 00 Street Address: 2' City State /Zip: / 0940 /1/e 33"a FL 4 0700 C6Z— te7/UE Woof Fax #: C / O o?.C) p -(0819 Contractor: 70 rr 4 /416 Phone: Street Address: City State /Zip: Fax #: Architect: Fge - l/- /T Ho Aivci- /STS, /Ale PS. Phone: 87 -, /00 Street Address: City State/Zip: /014o A/c 33P°' p4. Jeaoa 3 Evue wig 12067 Fax #: S vc 8- 6.5 9 e, 1 Engineer: iv/A- Phone: Street Address: City State /Zip: Fax #: Description of work to be done: Existing use: ,Retail ❑ Restaurant ❑ Church ❑ Manufacturing ❑ School /College /University ❑ Multi- family in Warehouse El Hospital ❑ Motel /Hotel ❑ Office ❑ Other Proposed use: ❑ Retail ARestaurant ❑ Church ❑ Manufacturing ❑ School /College /University ❑ Multi- family ❑ Warehouse ❑ Hospital ❑ Motel /Hotel ❑ Office ❑ Other Will there be a change of use? n yes ❑ no If yes, extent of change: (Attach additional sheet if necessary) F100/ RE7 L 7a ,� t icf+& . (CEKJi Will there be rack storage? ,� yes ❑ no Existing fire protection features sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: 31 (000 . .f. existing Area of Construction: (sq. ft.) a, a S 8' 5. ff • Will there be storage of flammable /combustible hazardous material in the building? ❑ yes 131 no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF T ",CWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 FOR STAFF USE ONLY Protect Number: Pc/6-00q 2- Permit Numbers ciG, >C7d2 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE./CIVIL'PLAN REVIEW OF THE FOLLOWING : Additional reviews ma be determined b the Public Works De . artment ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation Sanitary Side Sewer #: CI P GAS E I j ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): El Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: Application ta(cer3,by: (initials) CTPERMIT.DOC 7/9/96 BUILDING OWNER OR AUTH•RIZE /AGENT: Signatur :--- -( ,,- �, � Date: $' 30 G?&, Print name: 60,8 1SSt Phone: gad_ , Fax #: ax—e0 Address /1440 Ale 33 r ' 1 p , . u !rc c.)0 a City /State /Zip tic-U€1/06 WWI- ALL COMMERCIAL/MULTI-FIRMLY TENANT IMPROVEMENT /AL 'ATION PERMIT APPLICATIONS MOW BE SUBMITTED WITH THE FOL 0 WING: ➢ ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Five (5) sets of working drawings, which include : ❑ 1 Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). Floor plan: show location of tenant space with proposed use of each room labeled Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. Vicinity Map showing location of site Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. Indicate proposed construction of tenant space or addition and walls being demolished ti El 171 ❑ ❑ ❑ ❑ Construction details Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. Washington State Non - Residential Energy Code Date shall be noted on the construction drawings. SEPA Checklist - if intensification of use (check with Planning Department for thresholds). Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Certificate of Contractor ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architectengineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT / HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 7/9/96 Project Name/Tenant: , $R(.t,FC RS r<3A6-EL 13PIK.t - l¢.Y Existing use: ,Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel/Hotel ❑ Office ❑ School /College /University ❑ Other Value of Construction: b ow , o� ■ Site Address: City State /Zip: Pt FinRrl oN of 36 srietieoceE f3uJD. Tui r,_yq If yes, extent of change: (Attach additional sheet if necessary) o/L.! RE779/ 1- 7a ;��RutcA tor MAYc Tax Parcel Number. a<o a304 - Rcx,4 - 03 Property Owner: (E�e PRopEi2nES fire alarm ❑ none ❑ other (specify) Phone: 4J3- f 4,00 Street Address: g Ave City State /Zip: I S /l8 frig J # `!Q et ' or Fax #: Contact Person: K /mss /-Uf3 /SSE? Phone: 8...„27_ �/ Od Street Address: / 0140 de 33'd pe - p? City State /Zip: e'euEVVE Woo f Fax #: f'a8' -6899 O £ i /yEd Phone: Street Address: City State /Zip: Fax #: / / Architect: �/?E /l -f�/T 16 ALA' C/4/ rsS, mic ., es. Phone: / Sad -� / o 0 Street Address: /P 4o A/c 33 Po' pL . A` c;76.2 City State /Zip: iELC.EVUE wig y'Fcao¢ Fax #: 8- 6 S 9, Engineer: Ai/A- Phone; Street Address: City State /Zip: Fax #: Description of work to be done: Existing use: ,Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel/Hotel ❑ Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ,Restaurant ❑.MNulti- family ❑ Warehouse Hospital ❑ Church ❑ Manufacturing ❑ MoteUHotel ❑ Office ❑ School /College /University '❑ Other' Will there be a change of use? n yes ❑ no If yes, extent of change: (Attach additional sheet if necessary) o/L.! RE779/ 1- 7a ;��RutcA tor MAYc Will there be rack storage? yes El no Existing fire protection features sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: (000 Z. existing l Area of Construction: (sq. ft.) 'Q e ? S 8 s. ff. • Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF Tr 'KWILA Permit Center \- 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC -WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews,inay be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent #t' Size(s): El Water Meter Temp # Size(s): Est. quantity: gal Schedule: El Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: Application I r ,by: (initials) CTPERMIT.DOC 7/9/96 o210 * A*** ******* ** * * * *kk+4 ** *k•k*+ks4*k ***A*A - **AA* * *4 **•AA**4k4.**AkkA *A CITY OF TUKWILA. WA TRANSMIT ***: 4: 47h ,4 ****kA *k * *•k.W.4k * * *•k Akk *Ak *k•**** * *k *kk• *A . *Ak•A * * *A TRANSMIT Number: 89600491 Amount: 991.75 10/07/96 15 :25 Payment Method: CHECK Notation: COMMERCIAL STRUC Init: SLB Permit No: B96 -0263 Type: 13-BUILD BUILDING PERMIT Parcel No: 262304 -9064 Site Address: 361 STRANDER BL Total Fees: 1.633.46 This Payment 991.75 Total ALL Pmts: 1,633.46 Balance: .00 3* * A AA ***A**4 *•k **3A•*3 ****A*3 * **•A AAA *44. *33• *4*4 **AAA*•k*** A*AA**A ** Account Code •Description Amount 000/322.100 BUILDING - NONRES 987.25 000/3736.904 STATE BUILDING SURCHARGE 4.50 t 4900'2 3787 10/07 9605 TOTAL 1011.75 -k*• A** kk** A***** :4 *:4:k•k{r*+ *A***A *** *kk * * *A* *A *- k•kt***A *S*** **A*•kAir4 CITY OF TUKWILA. WA % TRANSMIT * * *•k *k* *•4 A * *A ** :4 *A•.4 *A * ** 4 *4* *•k:A3.4 * *k•4*4•A *•A 3 *A **+* *k4 *4 *•A* *•k l*•.A A TRANSMIT Number: P9600491 Amount: 20.00 10/07/96 15;27 `. Payment Method: CHECK Notation: COMMERCIAL STRUC Init: SLB Permit No: MI96•-0002 Tvoe: MISCPERM MISCELLANEOUS PERMIT Parcel No:' 262304-9064 Site Address: 361 STRANDER BL Location: IN FOOD PREPARATION AREA Total Fees: 20.00 This Payment 20.00 Total ALL Pots: 20.00 Balance: .00 * *A* AAA* * * ** * * *** * * * ** * *4* * ***A ** ** **•AAA *** * *A3 *A *A *•k * ** **4** ** Account Code Description Amount 402/342.400 INSP FEE - SME /CSS 20.00 3787 10/07 9605 TOTAL 1011.75 Account Code • 000/345.830 »it*+*a*k ++*k*+4.+A*++ a +++* A++*++++A*+^+a^+k+++**+A +'Ot++* �ITY OF TUKNILA. NA l|{h�S�I� **4 4*++++�+++* ++ h*+*A +��1^���+k x���8�r+� A A*+++A 4 TRANSMIT Number: R9600472 Amount: 641.71 08/30/96 09:3. Payment Method: CHECK Notation: PACIFIC CAPITAL %nit: SLB Permit Nn: 896-0263 Tvue: W-DUILD BUILDING PERMIT Parcel No: 262304'9064 Site Address: 375 STKAHDE8 OL Fatal Fees: 1.633.46 This Payment 641.71 Total ALL Pmts: 641.71 Balance: 991.75 a****+*+++a+aA+A*a++all***+4i+k*lk*+A++** Dascriotion PLAN CHECK - NONPES.. Amount 641.71 '2722 09/03 9617 TOTAL 641.71 ' ,avR 9l�Rr;,.x City 0, f Tukwila Fire Department Address 3( ^1 c r -t-A c :' Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: TU1 WILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name \ \.! L:_ a U.Ar) Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued 14H Authorized Signature Date FINALAPP.F,RM T.F.D. Form F.P. 85 ter 'kia V4r.i «. • :q�p..+jR -ts ' sxv.. s.n w!r.. -• .. John W. Rants, Mayor Thomas P. Keefe, Fire Chief _.V Permit No. 11 (l Suite # Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 Project:D,, Type of inspe on• Address:at \----,.. Date called: Special instructions: ( �3 p Date wanted: (I Z f ol�� m. .m.� Requester: Phone No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ,.pproved per applicable codes. Inspector: Date: PERMIT NO. tll 'ta 206) 431 -3670 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspebtion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: bikyL 6 6 16 Type of inspection:( C: nc d Address 4' /, ond f5+ Date called: Special instructions: MC o S56 Date wanted: a.m. p.m. Requester: Phone No.: Approved per applicable codes. -C : - INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector: I daAnat& Date: (o PERMIT NO. (206) 431 -3670 Corrections required prior to approval. COMMENTS: bcvA P povX V.6 (iu,t4tD g/ $42.00 REINVECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ri COMMENTS: Type of inspect N � L A¢ N Sf r� f � - '� S 0 k L T wcyt..L. Special instructions: t .I/4/ Date wanted: I' _ (O _ ¶ a.m. Requester: S - r . . t A I L Ga O +JS, A N'Y' 'r' t NF -" A 0 0 St:�Z=�'c`01 3 , IN P„rgje�c� n � Type of inspect N � L A¢ N Sf r� f � - '� Date called: 11 IS L9 Special instructions: t Date wanted: I' _ (O _ ¶ a.m. Requester: PhoneNo.: s .- __ $134 e...tft 4r4.nr.C.:ii �i i•A! ...0 tih':{.�(y:k X S%MV; •.. *t*%t+ +4 'r-a v^+l+�l% INSPECTI NO. Approved per applicable codes. INSPECTION RECORD Retain a copy with permit \q6- QZ(03 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 Corrections required prior to approval. Inspector: 7 ' c Date: ►� r* q(, $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Y.k.. k'...n.. _.... +?S_ �,. _ .,o. h, n,._4}.f..,.s .. , r_ :eleJ.. •. .n2._..r... ,: �..... Project: ..�,��,:,�.�CC -Ai� �Cii� Type of inspect;on. �.i�trr rJC7 Address: 3 4 , S PJO`f Date called: i t _ f Special instructions: Date wanted: / I _ f c, I a.ni. C p•r!ls Requester: ,4 t�� Phone No.: 575 31 3 y. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 pproved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO (206) 431 -3670 Corrections required prior to approval. COMMENTS: Inspector: Date: s 9.( $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ,a. r4_c!.i.. fr, +.1.��t....1. vu.r.- .e.w..,t_. t..... . ?I+hiF? .�s±'tel .e.etr.:r:.,...:. 7 i ., t 5. 10 � ` �_ . TTI/► Type gseon0 ' 1-� t � N Date called :t 1 _ 's , 9 t / 0 i �1 . Ire Special instructions: Date wanted:1 l p4 _ 9 a.. eryirp Requester: AR - I -- Phone No.: s- ,. C7 i at to tiYYr`::r.;s ?t;:x+rrwr INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit .,._�.:.�w: - �.... ?;«-'. �. �,+ b�v��.'• �c.' �+ s'?:; re' x..' � '�s..�.�a�dC...��'3at��`4�uhtrz Date : f j /Q( [ $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (206) 431 -3670 Approved per applicable codes. ["1-Corrections required prior to approval. COMMENTS: Inspector: Receipt No.: Date: Project: � Y 0- i Prs ,+ • . Type of inspection: • U2 i l j Grid Address: 1 a wpv Date called: („ 1 l ._ I@ YJ Special instructions: Date wanted: ' l (.3 p 1 .m. Requester: N Y � Phone No.: _ 15l5s o f �: � ; ,P.xwrz�rrs:,::rLt.••;rrws•�,�F ';;;rvXhV' INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 INSPECTION RECORD Retain a copy with permit (206) 431 -3670 Approved per applicable codes. [_Corrections required prior to approval. COMMENTS: Q 61 ►J m �1 • Appn-avA -4 -- itAvF ( S P ' • (=YCA- -, a( A,Prta j Inspector: c.4 Date: 1 9l0 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: . a... a.•....,.dM2dit,; $,,triki s t ...,_...0.5 .._ • o ec : • ..• a „ . Typ: of iospection: - I n 441 rinIsir RI Vdi . Date car/ / / , 0 Special instructions: Date wa, : y Re s e ?i il he (0 :hone ..... ,c....... / 3 cv.'a.rnara==.tr.EIXVM INSPECTION RECORD 3 Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: Inspector: A."4 4/1e.1 P6 Oa PERMIT NO. (206) 431-3670 Approved per applicable codes. Corrections required prior to approval. Date: $42.00 REINSPE TION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No,: Date: P eat s. -5 klej..5 TypNlkspagn: F j6/111,16 Date called: !O - 15 - Ito i e.er: 5 51._ Special instructions: Otp:0 I A't. Date wanted: 1 Z IR ID Requester: A Phone No.: 515 _ O 1311 INSPECTION NO CITY'OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Inspecto I r . at 0.1 4 INSPECTION RECORD Retain a copy with permit 4 r .� PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: /047_ $42.00 REINSPECTIO ' FEE RE . UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: kwa fE pl me) eLs Type of inspection mei Date called: 1 0 , 1 1 _ 9(0 .. vivl Special instructions: Date wantedi 0 _ 14 1 Requester:M Phone No.: s , 3 1 3 ,1_ INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 [ — ..c..t.....••=••r•b...kt.....sr..•74.;17.^.5.3:•,:sfr • .__ Lo— D2/45 PERMIT NO. (206) 431-3670 Approved per applicable codes. corrections required prior to approval. COMMENTS: &.. &r APPO-twipo. Inspector: Date: / $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project Info Protect Address A f - so, OF ; Date 8 /30 19(p 3105 STRANCER EbOI_I E\/ARD For Building Optattgamita CITY OF TUKWILA AUG 9 0 1996 PERMIT CENTER I` 105, /06, rrct-IeN F000 3j icF. Applicant Name: rmEIHEIr I Ho AIQcHirec iNC�P.S Applicant Address:'/�Qw r. ME 35" PL, Su 1 re 202 v 20( 0 ) Applicant Phone: C 8 p 7 - of oo eellxvoE Location (floonroom no.) Occupancy Oescnption Allowed Watts Der ft " Area in ft Allowed x Area 105, /06, rrct-IeN F000 3j icF. %xe M2 T 0.2 W/R EX6 tm Pr X07, /08, 109 Open Parking /iv, 10.2 D P. i P4Cr 1. 4.V 36 / , •736 /06 0 i•4 ' 3 1 .111M1111=111Men,....AL IIIIMMONNIII _=4. ._' 1 NOM 0 111110.11111 1111 0.25 Wift Bldg. (by periml ■ •._ 1.2U •..�t� + �� I _?-.._ _4 — From Table 15-1 (over) - document all exceptions taken from footnotes Total Allowed Watts / .736 Location (flaw/room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed o FLuoRe • I 1 .. • • x 0.2 W/R .: I Open Parking 0.2 W /R •_ �. ..:. �. Outdoor Areas ' 3 1 .111M1111=111Men,....AL IIIIMMONNIII _=4. ._' 1 NOM 0 111110.11111 1111 0.25 Wift Bldg. (by periml ■ •._ 1.2U •..�t� + �� I _?-.._ _4 ��tT.' Note: for building extenor, cnoose either the facade area or e penmeter method, but not both) Total Allowed Watts •.+ 1111; MINI Total Proposed Watts may not exceed Total Allowed Watts for Intenor Total Proposed Watts Location Descnotion Allowed Watts per ft or per If Area in ft (or M for penmeter) Allowed Watts x R (or x If) Covered Parking 0.2 W/R Open Parking 0.2 W /R Outdoor Areas 0.2 me Bldg. (by facade) 0.25 Wift Bldg. (by periml 7.5 WM Note: for building extenor, cnoose either the facade area or e penmeter method, but not both) Total Allowed Watts Location Fi ure Descnotion Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exc Total Allowed Watts for Extenor Total Proposes Watts Project Description 1994 Washin tor. State Nonresidential Ener. Code (' Form Lighting Summary LTG -SUM • 994 W avrnpron ,tale Nome... a.l Enarar t;oaa Comoaunce roans ❑ New Building ❑ Addition 4" A pill. 1994 Compliance Option 4 Prescnptrve 0 Lighting Power Allowance ❑ Systems Analysts (See Qualification Checklist (over). Indicate Prescnotive 8 LPA spaces clearly on plans.) Alteration Exceptions (check aopropnate box) 0 No changes are being made to the lighting ❑ Less than 60 % of the fixtures are new, and installed lighting wattage is not being increased Maximum Allowed Lighting Wattage (Interior) Proposed Lighting Wattage (Interior) (May not exceed Total Allowed Watts for Interior) Maximum Allowed hting Wattage (Exterior) Proposed Lighting Wattage (Exterior) (May not exceed Total Allowed Watts for Exterior) Lighting Permit Plans Checklist LTG -CHK 1 994 Wasntgon watt Energy t.oct Camonance roans Aoni. 1994 Protect Address A FT1D4 `1 OF 3141:6 STRAP10EIZ . VA2O I°' Si3o(4(c. The following information is necessary to checK a lighting permit application for compliance with the lighting requirements in the 1994 Washington State Nonresidential Energy Code. Applicaoilty (circle ones Code Section [ Component Information Reoutred Location on Plans Building Department Notes LIGHTIN CONTROLS Section 1513 ) no n.a. 1513.1 ' Local controlaccess Schedule with type. indicate locations A14 no n a. a 1513.2 Ana controls Maximum limit oar switch / 10 1 513.3 Daylight zone control Schedule with type and features. indicate locations 1 0 no n . vertical glazing Indicate vertical glazing on olans X13,0 yes no (1 f.'�j em ovee0 glazing Indicate overreact glazing on plans yes no V C 4 1513.4 Disolaylesnib/special Indicate separate controls 1513.5 Extent shut-off Schedule with type and features. indicate location " yes no i (a) timer wibaclao Indicate location yes no r1 (b) photocell. Indicate location 1513.6 Inter. auto shut-off Indicate location " yes no I . 1513.6.1 (a) • oceua. sensors Schedule with type and locations yes no .a} 1513.6.2 (b) auto. switches Schedule with type and features Iback•uo. ovemde caoabilityl: Indicate size of zone on plans LIGHT1NGlNATTA (Sections fSZ6-22 or 153042) h no Lighting Sum. Form Completed and attacned. � � Schedule with fixture types. _i fiITi[elte):i1- lamos. ballasts. watts per fixture • M L111 Yes no a ' Elec motor efficiency MECH -MOT or Eauioment Schedule with ho. rpm. efficiency 1994 Washingc State Nonresidential Energy Codfompliance Form no s circled for any question, provide explanation: Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Pubic Private Bathtubs and/or shower 4 2 Dental units or lavatory 1 - Dishwasher, commercial 4 - Drinking fountain (each head) 1 - Hose bibb or sill cock 5 3 Laundry tub or clotheswasher 4 2 Sink, bar avatory) 2 1 2. / Sink, clinic, flushing , 10 - Sink, kitchen 4 2 2 1 Sink, other 4 2 / 2 Sink wash, circle spray 4 - 3 1‘ Urinal, flush tank 3 - Urinal, pedestal 10 - Urinal, wall or stall 5 - Water closet tank 5 3 2.. / p Water closet, flush valve 10 6 *METRO Non - Residential Sewer Use Certification (To be completed for all new sewer connections, reconnections or change of use of existing connections. This form does not apply to repairs or replacements of existing sewer connections.) Pursuant to Metro Council Resolution Nos. 5719 and 5968, all sewer customers who establish a new service which uses metropolitan sewage facilities after February 1, 1990 shall be subject to a capacity charge. The Metro Council has established the amount of the charge at seven dollars ($7.00) per month por residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. The charge is collected semi - annually. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to Metro at 684 -1740. a47- C-7 ft (Please print or type) a, fj 4 9'is' `7111/ / 4r— Owner's Name SWV /"/f'ey ,P// V'l ,d/169"4" ,o Party to be Billed (if different from o�vrfgr r /Ar- , / CoV/771 ISIrrof last, First, Middle Initial) Property Legal Address : il Party's Mailing Address: (if different from property address) Subdivision Plat A 0 . ,6' c ,r // O Property Street -'S/ f7,4 -, 671' # 5. 4 4/0- 4 ,:::, /P'Lfl70,V,e),, coif 98 oil o Ad SdTl A ,G.41-Z,6t- . City, State, Zip 7-1((".4//:--,4" '' 76 City or Sewer District 114 14V t l.A. Owner's Phone Number ( ao/) .5.3 • /do P Date of Connection Owner's Mailing Address: (if different from above) Side Sewer Permit N 7/5" //87X .001/5"-4 ofre 447/G1. — if,/,,f ygoO✓'r' A. Fixture Units Number of Fixtures x Fixture Units = Total Fixture Units (Public or Private) Total Fixture Units Residential Customer Equivalents (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units 20 'ForMetro use • Account # MonthlyRate Six? Month Due 1058 (Rev. 6/91) White - Metro RCE .25 B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: "4 ,/-(64,9'— Estimated Wastewater Discharge: y °,t• ;- Gallons/day Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gaVday) 187 C. Total Residential Customer Equivalents: (add A & B) A B I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Si•nature of Owner/ RCE - Local Sewer Agency •nk - Sewer Customer d Bet to- B RCE RECEIVED OCT 0 61996 TUKWILA PUBLIC WORKS Print Name of Owner/ Representative 1 ' - L //tom Datef0 /X� • /14'4":- P , C> City of Tukwila U Department of Public Works Ross A. Earnst, P. E., Director NOTIFICATION OF UTILITY PERMIT ACTION TO: PERMIT CENTER FROM: PUBLIC WORKS ENGINEERING DATE: OCTOBER 3, 1996 SUBJECT: BRUEGGERS BAGEL BAKERY Grease Interceptor 361 Strander Boulevard Project No.: P96 -0092 Plan Check No.: B96 -0263 Activity No.: MI96 -0002 Contact Person: Ms. Kristen Lobisser Phone: (206)827 -2100 THE FOLLOWING PUBLIC WORKS PERMITS HAVE BEEN APPROVED FOR ISSUANCE IN ACCORDANCE WITH THE PLANS APPROVED ON October 3, 1996: MI96 -0002 Sanitary Side Sewer 20.00 Total Fees: $20.00 JJS /mv Attachments a/s C.F.: PW Utilities Inspector (copy of UPA, application and plans) Development File (copy of UPA, application and plans) PERMIT FEE John W. Rants, Mayor Two copies of the confirmed Utility Permit Application with a set of plans are attached for inclusion in the permit file. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: (206) 433-0179 • Fax (206) 431 DATE: /% CITY OF TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 PROJECT NAME: 041W¢¢�4'- A4' Z ' /€44= , / 91000 - . "/PA ,E 8-70 /fiPG�Td' arc. s. SUBMITTED TO: C� % Bldg. Planning Fire `= PLAN CHECK/PERMIT NUMBER: RECEIVED CITY OF TUKWILA OCT 021996 PERMIT CENTER REVISION SUBMITTAL 99 X4 o X 6,3 PROJECT ADDRESS: 3 �/ ST�1 � ��L�T/ CONTACT PERSON: iY �'i/if PHONE: a e2 fa47 4 2 /o REVISION SUMMARY: fro 44'4', ' ; APP A o?o ¢.ALOE/ i *- 4/ *0 ,4V. oo/P 00s& ly o srzv�p vs�- v¢ / • and ,4 c77'rt/ /f 4', f /IL /; ,l&Z 9z 7 yezfi -; rYfiAt/,eic e?/ /W76: SHEET NUMBER(S) — ,1 0? r 5' /13 1 ,4*2' --977 / "Cloud" or highlight all areas of revisions and date revisions. /yr,, ,pE � Ct Z' CITY USE ONLY Public;Works 3/19/96 44 .f.S.i.M7.:3wl #kZ /61. ,ivy: Vii' \S'rSY.l il:5 October 2, 1996 Attn: Kelcie J. Peterson Permit Coordinator City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 Re: Revision Letter #1 Development Permit Application Number B96 -0263 Bruegger's Bagel Bakery - 361 Strander B1 Southcenter Plaza, Tukwila, WA Again, thank you. Sincerely, FREIHEIT & HO ARCHITECTS, INC., P. S. Nancy Lim Associate Encl. cc: Larry Johnson, Pacific Capital Ventures, Inc. Project file FHOIet.doc FREIHEIT HO AI2CfIITECT8, INC., P.6. Evergreen One, 10940 NE 33rd Place, Suite 202 Bellevue, WA 98004 (206)827 -2100 RECEIVED CITY OF TUKWILA OCT 021996 PERMIT CENTER Public Works Department Enclosed, please find for your use, four (4) complete sets of revised plans with the appropriate revision block responding to the review comments from Public Works Department. Enclosed also is the completed Revision Sheet and Metro Non - Residential Sewer Use Certification accompanied this permit resubmittal. Building Department Per my telephone conversation with Mr. Ken Nelsen, Plan Examiner yesterday, October 1, 1996, it was determined that the existing exit corridor has no impact on the adjacent tenant space, Silver Platter. Thus Mr. Ken Nelsen has reversed his findings and no additional information is required from the Architect. We are herein requesting that this permit resubmittal to be expedited in plan routing as we did not receive the Revision Letter #1 in a timely manner. It is pertinent for us to obtain the permit so as to start and complete the construction on schedule without unnecessary loss of revenue. We would appreciate your prompt assistance in routing the revised plan sets to the Public Works as it is the only department that has commented on the drawings. r DONE ITIONAL A ILED EDASA N ION. AUSED SIR, ✓IDE WIRING .QUIRED RRANTY. IPMENT N, WARRANTIES, CTS BOUND IN ZIOR N BELOW UT NOT NE. RECORD. • STRANDER BLVD. • . y U z SITE E S 4. I F T 101N1 THAT PORTION OF THE SOUTHWEST O.)AR ER OF THE NORTHEAST QUARTER ER OFF SECTION 26, TOWNSHIP 25 NORTH, RANGE 4 EAST, OF THE WILAMEETTE MERIDIAN; IN KING COUNTY WASHINGTON. COMMENCING AT THE SOUTHWEST CORNER OF THE SOUTHWEST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 26; THENCE NORTH 01° 10' 24" EAST, ALONG SAID WEST LINE OF SAID SOUTHWEST QUARTER 12GE.E1 FEET TO THE SOUTH MARGIN OF STANDER BOULEVARD; THENCE SOUTH 55° 15' 55" EAST, ALONG SAID MARGIN, 665.00 FEET TO THE TRUE POINT OF BEGINNING OF THIS DESCRIPTION. THENCE SOUTH OI ° 44' 21" WEST, 65.00 EE T TO A POINT OF TANGENT CURVATURE CONCAVE TO THE NORTHEAST HAVING A RADIUS OF 150.00 FEET THENCE SOUTHEASTERLY ALONG SAID CURVE THROUGH AN ARC OF 54° 21' 01" AN ARC LENGTH OF 15.11 FEET; THENCE SOUTH 58° 15' 35" EAST, 212.1 1 FEET THENCE SOUTH 01° 44' 21" WEST, 62.00 FEET; THENCE SOUTH 65° 15' 33" EAST, ci 00 FEET; THENCE SOUTH 01° 44' 21" WEST, 62.00 _ET; THENCE NORTH 55° 15' 55" WEST, 155.00 FEET; THENCE SOUTH 01° 44' 21" WEST, 1E0.00 FEET; THENCE SOUTH 88° 15' 33" EAST, 2.x.32 FEET; THENCE SOUTH 54° 33'15" EAST, 20 4 .52 FEET; THENCE SOUTH 55° 15' 33" EAST, 115.14 FEET TO THE WEST MARGIN OF ANDOVER PARK WEST; THENCE NORTH 01° 05' 25" EAST ALONG SAID WEST MARGIN 515.42 F T TO THE SOUTH MARGIN OF STANDER BOULEVARD; THENCE NORTH 55° 15' 54" WEST ALONG SAID SOUTH MARGIN, 641.15 FL ET TO THE TR POINT OF BEGINNING AND TERMINUS OF THIS LEGAL DESCRIPTION. CITY RECEIVED OCT 021996 PERMIT CENTER Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Pubic Private Public Private Bathtubs and /or shower 4 2 Dental units or lavatory 1 — Dishwasher, commercial 4 — Drinking fountain (each head) 1 — Hose bibb or sill cock 5 3 Laundry tub or clotheswasher 4 2 Sink, bar o(t atory) 2 1 2. Sink, clinic, flushing 10 — Sink, kitchen 4 2 2 Sink, other 4 2 / 2 Sink wash, circle spray 4 — 4" Urinal, flush tank ' 3 — Urinal, pedestal 10 — Urinal, wall or stall 5 — Water closet tank 5 3 2-. / 0 Water closet, flush valve 10 6 "METRO Non-Residential Sewer Use Certification (To be completed for all new sewer connections, reconnections or change of use of existing connections. This form does not apply to repairs or replacements of existing sewer connections.) Pursuant to Metro Council Resolution Nos. 5719 and 5968, all sewer customers who establish a new service which uses metropolitan sewage facilities after February 1, 1990 shall be subject to a capacity charge. The Metro Council has established the amount of the charge at seven dollars ($7.00) per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. The charge is collected semi - annually. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to Metro at 684 -1740. (Please print or typ 4- /VOi . 1. 07Y/6 7— Owner's Name Sf'/E/f`� ' ,/E'1 9 " — A7 7- Property Legal Address Lut, First, Middle Initial) Subdivision Plat Property Street .36 / f7X..d' bt7P Ad Sdk �G -z,Q- City, State, Zip 7'/ Gr/� Arrxer City or Sewer District Owner's Phone Number ( ' ) �� - /do 0 Date of Connection Owner's Mailing (if different from above) Side Sewer Permit # 7/.0' //82 •� '-sg s'�/i // o A. Fixture Units Number of Fixtures x Fixture Units = Total Fixture Units (Public or Private) Total Fixture Units Residential Customer Equivalents (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units 20 1058 (Rev. 5/91) /s" White — Metro RCE Q23 For'Metro u se., 7: 1 Account # Monthly'Rate Six>Month Dut3.. , , .4e,4 WeerZ ,€4, Party to be Billed (if different from oWrtir �' /��a cm/9/7264 f'o,744 Party's Mailing Address: (if different from property address) o . ,6) yr // o /f. /no/r%, c.4 78o 79— 0 / B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: /f iL. ,f/(4&7_ Estimated Wastewater Discharge: y° /Vex"- Gallons/day Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (galday) 187 C. Total Residential Customer Equivalents: (add A & B) A B D /...0 RCE Yellow — Local Sewer Agency Pink — Sewer Customer egto- da (o B RCE I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Si nature of Owner/ senta iv zi/ Print Name of Owner/ Representative 1 p,G /st? Date /it C City of Tukwila September 26, 1996 Dear Ms. Lim: Building Department: Department of Community Development Steve Lancaster, Director Ms. Nancy Lim 10940 Northeast 33rd Place, Suite #202 Bellevue, Washington 98004 SUBJECT: REVISION LETTER #1 Development Permit Application Number B96 -0263 Bruegger's Bagel Bakery 361 Strander Bl This letter is to inform you of revisions that must be addressed before your application for development permit can be approved. All revision requests from each department must be addressed at the same time and reflected on your drawings. The following are comments from each of the reviewing departments: Fire Department: No Revision Comments. Planning Department: No Revision Comments. Contact Ken Nelsen, Plan Examiner, at (206) 431 -3670 if you have any questions regarding the following comments. 1. An overall building floor plan showing the adjoining tenant spaces and the impact on the existing exit corridor is required to complete plan review. John W. Rants, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 4313665 r;xx3?x.• '1;rrr• Ms. Nancy Lim September 26, 1996 Page 2 Sincerely, Kelcie J. Peterson Permit Coordinator Enclosure CER11tqED MAIL File: B96- 0263 Public Works Department: Contact Joanna Spencer, Development Engineer, at (206) 433 -0179 if you have any questions regarding the following comments. 1. A THERMCO grease interceptor is required. The applicant shall contact the Weiss Company at (206) 867 -9184 for the required size and model number. The applicant shall submit a catalog sheet and revise the plans to show the proposed grease interceptor location on Sheet A3.2 and add the model number and size to the kitchen equipment schedule on Sheet A3.4. 2. Applicant needs to submit a Metro Non - Residential Sewer Use Certification (enclosed), showing the net change in the amount of plumbing fixture units. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431 -3672. La&Af-r99 Sent to MS NANCY LIM Street and No. 10949 NE 33 PL #202 P.O., State and ZIP Code BELLEVUE WA 98004 Postage 1 �$ .32 Certified Fee • 1.10 Special Delivery Fee Restricted Delivery Fee Return Receipt Showing to Whom & Date Delivered 1. 10 Return Receipt Showing to Whom, Date, and Addressee's Address '1TAL Postage `ees • Q r 2.52 Postmark or Date MAILED 9/27/96 REVISION LETTER #1 • B96 -0263 it1)4Yii 40f;lit tai'3 a. 's1 IYAX `frIMMId inzc,ze aettscumwsa vssetwravzuserAr.. R * ,...a.,,., P 434 386 33? Receipt for Certified Mail An No Insurance Coverage Provided infirm Do Do not use for International Mail (See Reverse) O) 0) m C 0 CO M 0 N LL 0. .M1a^.fMMi •'r • tih V i4 tit 'f �$; . . t x*s ,fs:.. a3 ,..... r T 4 a ka T 3sr r� i s r -t .f I -, L O. �l 1 ° C n ' v � � s 6 .5 ! u .t' '!44,ttc ' C a It sf .ri& b % � R ?f Ater ; w ery s n .I� � x•r.: s � t . :;, OT �b s -'• �f /,= �M an brick If it CiP }�;h�1�z ®,Add►e.tsse a Ad i r } S S� {t rY a}a t ;s ! tmd oi±ths buo tM kirm b�r .R 2. 0 R sstrlcte l D.ily i ta ii to ' .,y.,.r..S'�tY S lk �. � �' +dX "Nt` �. aht r..- 're, lj'r �tel�.� i a rt = t 'C onsU r vi t i Of{ b Y t.. ' , Y . .� i a h '4' t i l `4. A W,Ntiinbit.'�+'f -10i ,' ' F? ' fi g: z� ' � { >gg��� -P, 34 -,, 4. 6 33 t}J Ia S J t Y1 7"" '� t h � 1.t',i'`nr�re f�x,.+.6 }A.Nr V.. � n�Y t � • , :i.„ ..�,. f . � w� .�K � x2R , f4 b S.rvJc. T�I p. t Exprs u M o►mr ._a. befi1 .9S. s x.. £ # ' w.ewa o wso rru...enrwsen:w..*C.W 11 LAi7Ri'.. i Fire Department Review Control #B96 -0263 (512) Dear Sir: City of Tukwila Fire Department Thomas P. Keefe, Fire Chief September 10, 1996 Re: Brueggers Bagel Bakery - 361 Strander Blvd. The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) A sodium bicarbonate or potassium bicarbonate dry - chemical -type portable fire extinguisher having a minimum rating of 40 -B shall be installed within 30 feet (9144 mm) of commercial food heat - processing equipment, as measured along an unobstructed path of travel. (UFC 1006.2.7) All new automatic fire - extinguishing systems and all modifications to existing automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575 -4439 City of Tukwila Fire Department Page number 2 Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Obstructions, including storage, shall not be placed in the required width of an exit, except projections as permitted by the Building Code. Exits shall not be obstructed in any manner and shall remain free of any material or matter where its presence would obstruct or render the exit hazardous. (UFC 1203) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit hardware and marking shall meet the requirements John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) .575-4404 • Fax (206) S75-44.39 ►r City of Tukwila Page number 3 Fire Department Thomas P. Keefe, Fire Chief of the Uniform Fire Code. (UFC 1207.1- 1212.8) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Exits shall not pass through kitchens, storerooms, restrooms, closets or spaces used for similar purposes. (UBC 1003.5) 3. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. An approved manual fire alarm system is required for this project. The fire alarm system shall meet the requirements of the Americans With Disabilities' Act, chapter 51 -20 WAC (Chapter 31 Accessibility), N.F.P.A. 72 and the City of Tukwila Ordinance #1742. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Call the Tukwila Fire Department at 575 -4407 for John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 Page number 4 Yours truly, The Tukwila Fire P er vention Bureau cc: •TFD file ncd City of Tukwila Fire Department approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1742) 5. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 6. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 • Fax (206) 575 -4439 13 th :. YP.:i ry;T-A:=-.. SCSd?Y3 444f be*, September 3, 1996 Dear Ms. Lobisser: City of Tukwila Department of Community Development Steve Lancaster, Director Ms. Kirsten Lobisser 10940 Northeast 33rd Place, #202 Bellevue, Washington 98004 SUBJECT: Development Permit Application Number D96 -0001 Bruegger's Bagel Bakery XXXX Strander BI Sincerely, Kelcie J. Peterson Permit Coordinator File: r> D96 =0001 FILE Corr John W. Rants, Mayor This letter is to inform you that your permit application received at the City of Tukwila Permit Center on August 30, 1996, was reviewed at the September 3, 1996, plan review meeting. Your application was determined to be complete. Your permit has begun the plan review process, you will be notified of any corrections or when your plan is approved. If you have any concerns or questions please contact me at the City of Tukwila Permit Center at (206) 431 -3672. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 • • TTMiTTW \1� \tw \'+T•�eY'r�+\ \\�T•.. ' �� w�Y. • ,� � ��.�� \ \ \l \ \ u \uuu \ \. ur \\�M4 \Y ` ��� ` :i\•W \W\.u.\•uu�, \ \ \ u�♦ ■ �: DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A OOPIKS it 84MK EP tTIM MTE CONST`;:CO fl : , •SENER . COMMERCIAL ST* WSE8 /NO" 1 F 0 SOX &SIMS SEATTLE WA 98160 • STATE OF WASHINGTON F625•062.00013.92) G ENERAL NOTES 21. ALL PORK SHALL BE GUARANTEED FOR A PERIOD OF ONE (I) YEAR AFTER COMPLETION, UNLESS OTHERWISE SPECIFIED, AND SHALL BE 50 STATED IN CONTRACTORS WRITTEN PROPOSAL AND AGREEMENT ALL REPAIRS, CORRECTIONS, DISCREPANCIES, ETC., MUST BE MADE WITHOUT ANY `ADDITIONAL COST TO THE OWNER AND WITHIN FIVE (5) DAYS AFTER NOTICE IS GIVEN. 22. ALL OPERATIONS CONDUCTED ON THE PREMISES SHALL NOT BE OBJECTIONABLE BEYOND THE PROPER,' BOUNDARY LINEN BY REASON OF NOISE, STEAM, ODOR, FUMES, GASES, SMOKE VIBRATION HAZARD OR OTHER CAUSES. IN ADDITION, THE CONTRACTOR SHALL MINIMIZE DISRUPTIONS OF ADJACENT TENANTS DUE TO NU ASE, ODOR, CORRIDOR FUMES, OR VIBRATION ALL COMMON LOBBY AND CORRIDOR SPACE SHALL BE KEPT CLEAR OF DUST, DEBRIS, AND CONSTRUCTION MATERIALS AT ALL TIMES. 23. LATHING, PLASTER AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO CHAPTER 25 OF THE 1114 UB.C. 24. ALL EXPOSED GYPSUM BOARD TO HAVE METAL EDGES AT ALL CORNERS AND WALL INTERSECTIONS. 25- ALL GLASS AND GLAZING SHALL COMPLY WITH CHAPTER 24 OF THE 1994 U.B.C. AND THE U.S. PRODUCT SAFETY COMMISSION: SAFETY STANDARD FOR FOR ARCHITECTURAL GLAZING MATERIALS (42 F - R 1426;16 CFR PART 1201. 26. THE CONTRACTOR SHALL VERIFY ALL DOOR AND WINDOW ROUGH OPENING DIMENSIONS WITH DOOR AND WINDOW MANUFACTURERS. 21. ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SNOWING THE SPECIFIC RATING. 28. ELECTRICAL ROUGH -IN, REFLECTED CEILING PLAN AND PLUMBING ROUGH -IN PLAN ARE FOR THE GENERAL INFORMATION OF THE CONTRACTOR. EXACT LOCATIONS SHOULD BE VERIFIED WITH THE OWNER. 21, EXIT SIGNS AND ILLUMINATION SHALL BE AS REQUIRED BY THE FIRE MARSHALL AND CHAPTER 10 OF THE 1994 UB C.. EXIT ILLUMINATION SHALL HAVE SEPARATE SOURCES OF POWER PER SECTION 1012.2. 30. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE 15E OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 31. FIRE EXTINGUISHERS, VERIFY REQUIREMENTS AND LOCATIONS WITH FIRE MARSHAL. CONTRACTOR TO SUPPLY FIRE EXTINGUISHERS AND CABINETS, AS REQUIRED. VERIFY LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION. 32. FLAMMABLE LIQUIDS SHALL NOT BE PLACED, STORED, OR DISPENSED IN THIS OCCUPANCY EXCEPT AS PROVIDED IN N.F.PA. STANDARD 30 AND THE CURRENT UNIFORM FIRE CODE. PERMIT MAY BE REQUIRED. O3. ALL DRAPES, HANGINGS, CURTAINS, DROPS, AND ALL OTHER DECORATIVE MATERIAL, INCLUDING CHRISTMAS TREES THAT WOULD TEND TO INCREASE THE FIRE AND PANIC HAZARD SHALL BE MADE FROM NON - FLAMMABLE MAT- ERIAL, OR SHALL BE TREATED AND MAINTAINED IN A FIRE RETARDANT CONDITION BY MEANS OF A FLAME RETARDANT SLUTION OR PROCESS AP- PROVED BY THE COUNTY FIRE MARSHAL. PROVIDE A CERTIFICATION TO THIS EFFECT. A. EXIT DOORS, EXIT LIGHTS, AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL B. MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISHES SHALL BE PER THE 1914 UNIFORM BUILDING CODE. 34. ALL LAY -IN ACOUSTICAL CEILING GRIDS SHALL BE INSTALLED AND SECURED PER THE REQUIREMENTS OF THE 1994 UB.C„ CHAPTER 25. 35. THE LIVE LOADS FOR EACH FLOOR, OR PART THEREOF, OF A COMMERCIAL INDUSTRIAL BUILDING WHICH HAVE BEEN DESIGNED, SHALL HAVE SUCH DESIGNED LIVE LOADS CONSPICUOUSLY POSTED BY THE OWNER IN THAT PART PART OF EACH STORY IN WHICH THEY APPLY (ZING DURABLE METAL SIGNS, AND IT SHALL BE UNLAWFUL TO REMOVE OR DEFACE 5/CH NOTICES. THE OCCUPANT OF THE BUILDING SHALL BE RESPONSIBLE FOR KEEPING THE ACTUAL LOAD BELOW THE ALLOWABLE LIMITS. 36. SOUND INSULATE ALL PLUMBING WALLS. 31. ALL MECHANICAL, ELECTRICAL, FIRE SPRINKLER, AND SIGNAGE WORK TO BE FILED UNDER SEPARATE PERMIT. 30. ALL MECHANICAL, ELECTRICAL, AND FIRE SPRINKLER PORK TO BE BIDDER DESIGN. 39. ALL CONTRACTORS ON THE JOB SHALL MAINTAIN CURRENT CITY OF TUKWILA BUSINESS LICENSES WRING THE CONSTRUCTION OF THIS PROJECT. 40. THE CONTRACTOR SHALL ENSURE THAT THIS PROJECT, AND ALL CONSTRUCTION ACTIVITIES RELATED THERETO, CONFORM WITH ALL LOCAL, REGIONAL, STATE AND /OR FEDERAL REGULATIONS PERTAINING TO DISTURBING, DISPLACING, AND /OR REMOVAL OF ASBESTOS OR ASBESTOS CONTAINING MATERIALS. NOTE SPECIFICALLY, THAT THE CONTRACTOR SHALL CONFORM WITH THE REQUIREMENTS OF THE PUGET SOUND AIR POLLUTION CONTROL AGENCY REGARDING INSPECTION CERTIFICATION, AND NOTIFICATION. 41. THE CONTRACTOR SHALL RECEIVE, STORE, AND PROTECT OWNER FURNISHED EQUIPMENT 42 THE CONTRACTOR SHALL MAINTAIN INSURANCE AS REQUIRED BY OWNER AND LENDER. 43. RESPECTIVE CONTRACTORS ARE TO FURNISH 4 (FOUR) PRINTS OF SHOP DRAWINGS FOR APPROVAL. SHOP DRAWINGS ARE TO BE NEWLY PREPARED INFORMATION FULLY DIMENSIONED, DRAWN TO SCALE WITH ANY DEVIATIONS FROM THE CONTRACT DOCUMENTS CLEARLY INDICATED. PROVIDE MANUFACTURERS PRODUCT DATA FOR ALL PROPOSED EQUIPMENT. 44. THE REQUIRED SHOP DRAWINGS AND SUBMITTALS SHALL INCLUDE, BUT NOT BE LIMITED TO: SUBCONTRACTORS LIST, BAR CHART SCHEDULE, MILLWORK, DOOR HARDWARE 4 OPENING SCHEDULE, TILE FLOORING, PAINT BRUSHOUTS, INTERIOR FINISHES, TOILET ROOM ACCESSORIES, PLUMBING PLAN, PLUMBING FIXTURE CUT SHEETS, HVAC PLAN 6 EQUIPMENT LIST, ELECTRICAL PLAN AND LIGHTING FIXTURE CUT SHEETS. 45 SUBSTITUTION REQUESTS WILL ONLY BE ACCEP 1G, PRIOR TO THE COMMENCEMENT OF WORK. SUBMIT PROPOSAL, INCLUDING PRODUCT SPECIFICATIONS AND SAMPLES TO ARCHITECT FOR REVIEW. ALL SUBSTITUTIONS MOST BE APPROVED BY ARCHITECT, OWNER AND BRUEGGER'S CORPORATION. 46. ALLOW A MINIMUM OF I (ONE) WEEK FOR THE REVIEW AND APPROVAL OF SHOP DRAWINGS. DO NOT USE SHOP DRAWINGS WITHOUT A FINAL STAMP INDICATING ACTION TAKEN IN CONNECTION WITH CONSTRUCTION. 41. ALL NECESSARY PERMITS, LICENSES. AND INSPECTION FEES SHALL BE PAID FOR AND ARE THE RESPONSIBILITY OF THE RESPECTIVE CONTRACTOR. 48. CONTRACTOR SHALL PROVIDE OWNER WITH SATISFACTORY "MECHANICS LIEN WAIVER" WITH SUBMISSION OF EACH PATIENT REQUEST. 49. ALL PORK INVOLVED IN THIS PROJECT 'AVALL BE NEW AND REFLECT THE BEST POSSIBLE WORKMANSHIP. ANY WORK WHICH IS NOT, SHALL BE CORRECTED OR REDONE AS 15 REQUIRED FOR APPROVAL BY THE ARCHITECT AND /OR OWNER, AT NO ADDITIONAL COST TO THE OWNER. 50. CLEAN ALL DOORS WINDOWS, FLOORS, CARPETS, AND ALL OTHER SURFACES SOILED DURING CONSTRUCTION. REPAIR OR REPLACE ANY ITEMS OR SURFACES DAMAGED AS A RESULT OF THE CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER. 51. THE CONTRACTOR SHALL PROVIDE SUFFICIENT ATTACHMENT AND IN -WALL HIDDEN BLOCKING REQUIRED FOR WALL HUNG ITEMS EQUIPMENT AND OTHER CONSTRUCTION. 52, THE CONTRACTOR SHALL COORDINATE THE WORK OF `SUBCONTRACTORS ON THE JOE AS THE PREVENT CONFLICTS DURING CONSTRUCTION. ADDITIONAL WORK CAUSED BY A LACK OF COORDINATION BETWEEN CONTRACTORS SHALL NOT BE AT THE OWNER'S EXPENSE. 53. MU51C SYSTEM, ALARM SYSTEM AND SIGNAGE TO BE PROVIDED AND INSTALLED BY OTHERS. GENERAL CONTRACTOR TO PROVIDE POWER TO THESE ITEMS AS REQUIRED AND TO COORDINATE INSTALLATION SCHEDULE. 54. ELECTRICAL CONTRACTOR TO PROVIDE TELEPHONE WIRE. WIRE SHALL BE 4 PAIR LEVEL 3, 24 GAUGE, PVC OR PLENUM ENVIRONMENT RATED (IF REQUIRED). PROVIDE WIRE FROM EACH OUTLET TO PANEL LOCATION SHOWN. SEE TELEPHONE 4 DATA WIRING DIAGRAM ON SHEET E -I. 55. THE CONTRACTOR SHALL VERIFY WITH LANDLORD ALL NECESSARY ROOF AND WALL PENETRATIONS, FLASHINGS, SEALANTS, PITCH POCKETS, AND ORBS AS REQUIRED FOR HVAC EQUIPMENT AND REMOTE CONDENSERS AND NOT VOID ANY ROOF WARRANTY. 56 CONTRACTOR TO VERIFY LOCATION AND HOOK UP REQUIREMENTS FOR ALL EQUIPMENT (SEE EQUIPMENT SCHEDULE). NOTIFY ARCHITECT OP ANY DISCREPANCIES WITH CONSTRUCTION DOCUMENTS. 51. CONTRACTOR TO COORDINATE INSTALLATION OF REMOTE CONDENSERS WITH EQUIPMENT INSTALLATION COMPANY, CONTRACTOR TO PROVIDE ALL NECESSARY DOPER TO REMOTE CONDENSERS. 58. COLOR OF THE FOLLOWING ITEMS TO MATCH ADJACENT FINISH SURFACES AS SPECIFIED ON ROOM FINISH SCHEDULE ON SHEET IMO. I. HOAG DIFFUSERS AND REGISTERS 2. ACCESS PANELS 3. SPEAKER GRILLES AND COVERS. 59. WATER RESISTANT GYPSUM WALL BOARD SHALL BE USED FOR ALL WASHROOM, KITCHEN AND OTHER MOISTURE AREAS UNLESS OTHERWISE INDICATED. 60. ALL FLUORESCENT LIGHT FIXTURES TO HAVE ELECTRONIC BALLASTS. 61. CONTRACT CLOSE -OUT, PROVIDE FOUR SETS OF ALL MAINTENANCE INFORMATION, WARRANTIES, GUARANTEES, OPERATION MANUALS, SPARE PARTS LISTINGS AND SERVE CONTRACTS BOUND IN THREE RING NOTEBOOKS. INCLUDE INFORMAT,ON FOR, BUT NOT LIMITED TO, INTERIOR FINISHES, FOOD SERVICE EQUIPMENT, PLUMBING, ELECTRICAL AND HVAC SYSTEMS. 62. RECORD ON A RECORD SET OF DRAWINGS THE EXACT LOCATION AND ELEVATION BELOW FINISH FLOOR OF ALL BURIED UTILITIES UNCOVERED BY THE WORK, INCLUDING, BUT NOT LIMITED TO: DRAIN LINES, STORM DRAINAGE, WATER ELECTRICAL AND TELEPHONE. RECORD, INITIAL AND DATE ALL MARKS AFTER ALL UTILITIES ARE ARE CONNECTED BEFORE COVERING. 63. THE FOLLOWING INFORMATION MUST BE SUBMITTED TO THE OWNER PRIOR TO THE RELEASE OF RETENTION: COPY OF COMPLETED PUNCH LIST, COPIES OF RECORD DRAWINGS, MAINTENANCE MANUALS, FINAL COPY OF SUBCONTRACTORS LIST, CERTIFICATE OF OCCUPANCY AND SIGNED OFF BUILDING PERMIT 64. AT THE COMPLETION OF THE JOB THE CONTRACTOR SHALL REMOVE ALL TEMPORARY FACILITIES FROM SITE ALONG WITH CONSTRUCTION TOOLS, MATERIALS AND EQUIPMENT. VACUUM CLEAN PROJECT, INCLUDING ALL HEATING DUCTWORK AND REGISTERS. HAND DUST AND CLEAN WALLS, CEILING, WOOD WORK, SHELVING AND CABINETS WASH MIRRORS AND ALL GLASS ON BOTH SIDES. CLEAN PLUMBING FIXTURES TO A SANITARY CONDITION, CLEAN SITE OF ALL RUBBISH AND FOREIGN DEBRIS DUE TO CONSTRUCTION. WASH ALL FLOORING AND REMOVE ALL NON - ESSENTIAL LABELS FROM GLASS, FIXTURES, ETC. /IGINITY MAR' ESJN f=71 N THAT PORTION OF THE SOUTHWEST QUARTER OF THE NORTHEAST QUARTER OF SECTION 26, TOWNSHIP 23 NORTH, RANGE 4 EAST, OF THE WILANETTE MERIDIAN{ IN KING COUNTY WASHINGTON. COMMENCING AT THE SOUTHWEST CORNER OF THE SORHNEST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 26; THENCE NORTH OT 10' 24' EAST, ALONG, SAID VEST LINE OF SAID SOUTHW T QUARTER 129357 FEET TO THE SOUTH MARGIN OF STANDER BOULEVARD; THENCE SOUTH 88° 15' 33' EAST, ALONG SAID MARGIN, 665.00 FEET TO THE TRUE POINT OF BEGINNING OF THIS DESCRIPTION THENCE 500TH 01° 44' 2T WEST, 6300 FEET TO A POINT OF TANGENT CURVATURE CONCAVE TO THE NORTHEAST HAVING A RADIUS OF 0000 FEET; THENCE SOUTHEASTERLY ALONG SAID CURVE THROUGH AN ARC OF SHE 21' 01" AN ARC LENGTH OF 15)1 FEET; THENCE SOUTH 8H° ID 33' EAST, 2120 FEET; THENCE SOUTH 01° 44' 21' PEST, 6200 FEET; THENCE SOUTH 88° 15 33' EAST, 9.00 FEET; THENCE SOUTH 01° 44' 21' WEST, 6200 FEET, THENCE NORTH BB° 15' 33' PEST, 13300 FEET, THENCE SOUTH OF 44' 2T WEST, 150.00 FEET; THENCE SOUTH 88°15'33' EAST, 21192 FEET; THENCE SOUTH SHE 33' l8" EAST, 20452 FEET; THENCE SOUTH 58° 15 33° EAST, 116.14 FEET TO THE WEST MARGIN OF ANDOVER PARK WEST; THENCE NORTH DI' 03' 25' EAST ALONG SAID PEST MARGIN 51542 FEET TO THE SOUTH MARGIN OF STANDER BOULEVARD; THENCE NORTH 8B° 15' 34" PEST ALONG SAID SOUTH MAR61N 64113 FEET TO THE TRUE POINT OF BEGINNING AND TERMINUS OF THIS LEGAL DESCRIPTION. AO.O A2.0 A3.1 A3.2 A3.3 A3.4 A40 A6.0 A6.1 A62 A6.3 A6.4 A1.0 A90 A9.1 Al 2 MPEI MPE2 MPES E PI P2 COVER SHEET. GENERAL NOTES 4 PROJECT DATA BUILDING PLAN FLOOR PLAN KITCHEN EQUIPMENT PLAN EQUIPMENT SCHEDULE EQUIPMENT SCHEDULE INTERIOR ELEVATIONS INTERIOR DETAILS INTERIOR DETAILS CABINET DETAILS CABINET DETAILS CABINET DETAILS REFLECTED CEILING PLAN 4 LIGHTING FIXTURE SCHEDULE FINISH SCHEDULE, DOOR SCHEDULE, DOOR HARDWARE SCHEDULE INTERIOR FINISH DIAGRAM WALL TYPE LEGEND MECHANICAL, PLUMBING 4 ELECTRICAL GENERAL NOTES MECHANICAL, PLUMBING 4 ELECTRICAL GENERAL NOTES MECHANICAL, PLUMBING 4 ELECTRICAL GENERAL NOTES ELECTRICAL ROUGH -IN PLAN PLUMBING ROUGH -IN PLAN PLUMBING FIXTURE SCHEDULE GOVERNING CODE: 1994 UNIFORM BUILDING CODE AS ADOPTED BY THE CITY OF TUKWILA. PROJECT ADDRESS: A PORTION OF 365 STRANDER BOULEVARD TUKWILA, WA ZONE OF PROPERTY: TAX LOT ID NUMBER, OCCUPANCY TYPE: CONSTRUCTION TYPE. OCCUPANCY LOAD CALCULATION: KITCHEN/FOOD SERVICE DINING RESTROOMS TOTAL, PROJECT VALUATION, BUILDING OWNER: TENANT ARCHITECT TUC. (TUKWILA URBAN CENTER) A262304- 1064 -03 A -3 V -N, SPRINKLED 1022 SQ. FT. 1,104 50. FT. 132 SOFT. 2250 5Q. FT. .120000 3 1/200 0 1/15 H 1900 SPIEKER PROPERTIES 915 110TH AVE. SE, SUITE 110 BELLEVUE, WA 98005 -0055 (206) 453 -1600 CONTACT: STEPHANIE FASANJ BRUEGGERS BAGEL BAKERY 0/0 PACIFIC CAPITAL VENTURES, INC. PO BOX 110 REDMOND, WA 98015 -0110 (206) 861 -5120 CONTACT: LARRY JOHNSON FREIHEIT 4 HO ARCHITECTS, INC., P5. 10940 NE 33RD PLACE, SUITE 202 BELLEWE, WA 98004 (206) 821 -2100 CONTACT: NANCY LIM 511 13.6 132 80.03 CITYROFETUKWILA ofr 0 2 (900 C, 0 QV6 PERMIT CENTER ?f*» b3 I. THE PROJECT CONSISTS OF SHELL ALTERATIONS AND TENANT IMPROVEMENTS TO A LEASED SPACE AT SOUTHCENTER PLAZA, TUKWILA, WASHINGTON. THE WORK INCLUDES CONSTRUCTION OF TENANT IMPROVEMENTS AS DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS BY FREIHEIT 4 HO ARCHITECTS, INC., P.S., EXCEPTING ONLY THOSE ITEMS SPECIFICALLY SHOWN AS "NOT IN CONTRACT" (NIL) OR "SY OWNER ", OR AS DESCRIBED HEREIN. WORK BY OTHERS UNDER SEPARATE CONTRACTS SHALL BE BASED ON CONTRACTORS ASSUMPTIONS AND CLARIFICATIONS. 2 CONTRACTOR TO CONDUCT PROJECT MEETINGS AT WEEKLY INTERVALS DURING THE CONSTRUCTION PHASE. NOTIFY ARCHITECT AND OWNER OF SCHEDULED DATES. AGENDAS TO INCLUDE REVIEWING SIGNIFICANT ITEMS THAT COULD AFFECT THE PROGRESS OF THE WORK AND TOPICS APPROPRIATE TO THE CURRENT STATUS OF THE PROJECT. ALSO, REVIEW ACTIVITIES IN RELATION TO THE CONSTRUCTION SCHEDULE AND WHETHER REVISIONS TO THE SCHEDULE ARE REQUIRED FOR COMPLETION WITHIN CONTRACT TIME. 3. THE AIA NA2OI 1981 EDITION STANDARD FORM OF GENERAL CONDITIONS SHALL BE A PART OF THESE CONTRACT DOCUMENTS AND SPECIFICATIONS AS IF BOUND HEREIN. 4. ALL CONSTRUCTION SHALL COMPLY WITH THE 1114 UNIFORM BUILDING CODE (U.B.C.) AS ADOPTED BY THE CITY OF TUKWILA, WA., AND ALL APPLICABLE LOCAL CODES ORDINANCES, AND STANDARDS. 5. CONTRACTOR 15 TO VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC., AND NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. b. ALL ITEMS MARKED WIC' ARE NOT PART OF THIS CONTRACT. 1. ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S LATEST RECOMMENDATIONS OR WRITTEN DIRECTIONS. 8. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. THE CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY AND ALL DISCREPANCIES. 9. ALL DIMENSIONS ARE TO FINISH FACE OF WALL, CENTERLINE OF COLUMN, OR FACE OF CONCRETE WORK UNLESS NOTED OTHERWISE. 10. DIMENSIONS SHOWN ARE APPROXIMATE. DUE TO HIDDEN CONDITIONS AND BUILDING IRREGULARITIES EXACT DIMENSIONS MAY VARY SLIGHTLY AND THEREFORE MUST SE FIELD VERIFIED PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES, II. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 12. WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR, IT 15 INTENDED THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES, ITEMS OR PARTS AS ARE REQUIRED TO PROPERLY COMPLETE THE WORK. 13. CONTRACTOR SHALL VERIFY ALL "BUILDING STANDARDS" WITH BUILDING LANDLORD PRIOR TO BEGINNING ANY WORK. HOWEVER, THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF, THE CONTRACTOR AGREES TO DEFEND, INDEMNIFY, AND HOLD THE ARCHITECT HARMLESS FROM ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. 14. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF HIS WORK. 15 THE CONTRACTOR HILL VERIFY AND CONFORM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UNLESS OTHERWISE NOTED IN THE PLANS AND SPECIFICATIONS. I6. EXISTING ELEVATIONS AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY THE CONTRACTOR BEFORE CONSTRUCTION STAKING. IF THEY DIFFER FROM THOSE SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT 50 THAT MODIFICATIONS CAN BE MADE BEFORE PROCEEDING WITH THE WORK. IT, ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN (BROOM) CONDITION AT ALL TIMES. 18. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES. IN APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS WELL AS ALL REVISIONS ADDENDA, AND CHANGE ORDERS. THE nNTRACTOT SHALL ALSO MTAINiTAiir iN GOOD CONDITION, ONE COMPLETE 5E7 OF PLANS Elm ALL REVISIONS, ADDENDA, AND CHANGE ORDERS, ON THE PREMISES AT ALL TIMES WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT 20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE BUILDING AND SITE WHILE JOB 15 IN PROGRESS AND UNTIL THE THE JOT IS COMPLETED. BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON SOUTHG TK ,A, V - R F ,A7A L�. M ��e'�TT SEPARATE ER DT REQUIRED FO: MECHATIIC CL S ELECT' ❑ FLUNTS. GAS CT • Lo3LNULCdGGEET IADI L �W PIE® Pat LE 400 REVISIONS ?Qi fIlIEI[T al HO CHI`)[ CT 4 INC DA Evergreen One. 40940 NE 33rd Place, Suite 202. Bellevue, WA 90004 (208 927 -2105 N o ARCH I'LS RICHARD 0 EREIHEirt, SATE OF GUN w G DRAWN BY- KAL DRAWING NAME: 1623100 DATE: 0/19/96 PROJECT NO.: 96_31 SHEET A0.0 OF BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON REVISIONS I 6 REGISTERED FRED C N t;s �, �v �crav f PRINT DATE: 0 8/29/96 0805 DRAWN BY: KAL SHEET AZ.O OF o - - ��RoS IA GE, O E � - - -- - - -- ''66° FD IH IT HO A J Cll 1LECTA4 I Poi INC., ❑ DRAWING NAME: 9623 20 DATE: 8/19/96 W ®� ce ¢ � o Evergreen One, 10940 NE 33rd Place, Suite 202, Bellevue, WA 98004 (206 827 -2100 PROJECT NO.: 16237 ti f_31 - to 3 26O' -O" (EXISTING CORRIDOR/ 265' -O° rr Yl EXISTING EXIT CORRIDOR I -HOUR CONSTRUCTION TALLY SPRINKLED BUILD I NG PLAN O 50ALE: I /I6 " =1' -O" — AREA UNDER THIS PERMIT _` 5-0" EXTENSION SEE DETAIL II /A60 0 F - - NEW TAUNT DO4ISIN6 WALL T CITVHOFETAILA 020 0 7 1090 BRUEGGER'S BAGEL BAKERY ENTER PLAZA TUKWIL TUKWILA, WASHINGTON RECISIONS ryry} ryry rry lL I IIIIIEIT L4* 110 CHImfl CTL INC D Evergreen One, 10940 NE 33rd Place, Suite 202, Bellevue. WA 98004 (206 424- 100 taT $ ,-•^". a , <� ,a n r; V PRINT DATE 09109/96 0030 oRAwN SHEET A3.1 OF o � Tr. o 5 � �L1U� iS d � �J1L'J15U 1A GEL ilBLti>I ^ \,� ����� // �U— AMN 9623730 0/19/96 ®A R ® ff W _ 9523 CT NO.. PAb O PORTION OF 0015TING STOREFRONT TO BE REMOVED TO AGCOMODATE NEW DOUBLE ENTRY DOORS. ALIGN V`• RO. STORAGE BAKE AREA NEW ELECTRICAL PANEL LOCATION. CLEAR 0 _ 1 PREP AREA 5' -4 I/O" O FLOOR PLAN SCALE: 1/4" =1' -0" PROVIDE 3" 0 PVC. CHASE FOR SODA LINES PER DETAIL 5 /A6.0 EXISTING TENANT DEMISING WALL PURR EXISTING WALL W/ 3 5/0" 20 GA. MTL STUDS 424: O (I) LATER 5/8" W R. 0160 NOTE: SEE DETAIL 5/A6.1 FOR RESTROOM ELEVATIONS. PORTION OF EXISTING WALL CONSTRUCTION TO BE REMOVED od DINING AREA 4' -I I/2' CIO RECESSED WALK -OFF MAT 3'-6 1/2' 30' - II I /3" VERIFY IN FIELD 135 °" 9' -H 1/2" ,! EXISTING EMERGENCY EXIT DOOR TO BE REMOVED. INFILL YV STOREFRONT TO MATCH EXISTING NEW TENANT DEMISING WALL 6" 20 GA. MTL. STUDS ® I6 " 5/6" TYPE 'X' GAB EACH SIDE TO UNDERSIDE OF STRUCTURE ABOVE PROVIDE 3" 0 PVC CHASE FOR SODA LINES PER DETAIL 5/A60. IIT 0 G \ �KWF�� (lPN LINE OF HOT WATER HEATER '6') PLATFORM ABOVE. SEE 0I; I DETAIL 1/A6.1. IN �ION DRAWING LEGEND e ^'' EXISTING HALL WALL TO BE REMOVED NEW WALL rv CI ILA OCT 0 21000 PERMIT CENTER B R U E G G E R S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON REVISIONS A ADDENDUM 7<2 REVISIONS 9/24/96 Q ADDENDUM u3 REVISIONS 9/26/96 PERMIT REVISIONS - PUBLIC WORKS T�Iryy- ¶ �I{'�I� �L f�� f� fL � � ❑ 827 -2100 � p CIS 7 ' 1 nn 'r� j p II .1 � ] d l I a r_. 6 m , = , 2 E -6 •ti 1 I -, H DRAWN BY KAL SHEET A r A P L OF DRAWING NAME 9623130 DATE: 10)1/96 A �� LT71' II 9CT INC aC�a 1 \ \ I II L IIILllll 11LL .11lt'.d. 111L 1llLl \ \VI 1) Evergreen One, 10940 NE 33rd Place, Suite 202, Bellevue, WA 88004 (206 PROJECT NO: 16241 HEALTH DEPARTMENT NOTES I) ALL FOOD SERVILE EQUIPMENT AND INSTALLATION SHALL COMPLY WITH THE CURRENT EDITION OF CODES RULES Ault REGULATIONS OF THE GOVERNING HEALTH DEPARTMENT AUTHORITIES. ARRANGE FOR INSPEC- TIONS A REWIRED TO COMPLETE THE WORK. 2) ALL EQUIPMENT AND FOOD STORAGE SHELVING SHALL BE NSF. APPROVED. 3) TABLE MOUNTED EQUIPMENT, THAT 15 NOT PORTABLE (PORTABLE EQUIPMENT 15 LESS THAN '15 LBS. WITH NO RIGID UTILITY CONNECTIONS) SHALL BE MOUNTED ON LEGS NO LESS THAN FOUR INCHES IN HEIGHT OR SEALED TO THE TABLE 0* COUNTER. 4) FLOOR MOUNTED EQUIPMENT SHALL BE MOUNTED ON CATERS WITH FLEXIBLE UTILITY CONNECTIONS OF ADEQUATE LENGTH (OR WITH FLEXIBLE CONNECTIONS WITH QUICK DISCONNECTS)- SHALL BE PROPERLY SPACED FROM THE FLOOR AND WALLS PER HEALTH DEPARTMENT REouiRET-RTITS. OR SHALL BE SEALED TO THE WALLS AND FLOORS OR BE CONSIDERED PORTABLE (LESS THAN `f5 LBO. AND NO RIGID UTILITY CONNECTIONS(. 5) RAISED FLOOR PLATFORMS ARE NOT ACCEPTABLE WHERE WASTE CONNECTIONS ARE COVERED AND CANNOT BE ADEQUATELY SEALED IN PLACE 6) ALL UTILITY LINES SHALL BE ELEVATED AT LEAST SIX INCHES OFF THE FLOOR AND ONE HALF INCH FROM THE WALLS. 1) EACH COLD STORAGE UNIT SHALL BE PROVIDED WITH THERMOMETERS SCALED IN 5 DEGREE P INCREMENTS. a) EIGHT INCH HIGH SPLASH GUARDS SHALL BE INSTALLED AT HAND SINKS WHEN FOOD CONTACT SURFACES, VEGETABLE OR THREE COMPARTMENT SINKS ARE WITHIN A DISTANCE OF EIGHTEEN INCHES HORIZONTALLY. SPLASH GUARDS SHALL HAVE 9" RADIUS COVE, BE SECURELY FASTENED AND BE EASILY CLEANABLE. 9) LAMP GUARDS OR SLEEVES SOLID PLASTIC LENSES OR APPROVED COATED BULBS SHALL BE USED ON ALL LIGHTING IN EQUIPMENT OR OVER FOOD CONTACT AREAS. 10) ALL FLOOR DRAINS, HUB DRAINS AND FLOOR SINKS ACCEPTING INDIRECT WASTE OR CONDENSATE SHALL HAVE MINIMUM ONE INCH AIR GAPS. II FLOORS IN FOOD PREPARATION FOOD STORAGE, UTENSIL WASHING, AND JANITORIAL AREAS SHALL MEET HEALTH DEPARTMENT REQUIREMENTS AND SHALL HAVE A COVED BASE, 12) WALLS AND CEILINGS IN FOOD PREPARATION, FOOD STORAGE UTENSIL WASHING AND JANITORIAL AREAS SHALL BE APPROVED NONAB' DENT D,RABLE AND EASILY CLEANABLE MATERIALS, MATERIALS IN VET AREAS SHALL BE MOISTURE RESISTANT. IS) SEPARATE EMPLOYEE LOCKERS OR COAT HOOKS SHALL BE PROVIDED AWAY FROM FOOD STORAGE AREAS. 14; CLEANING CHEMICALS AND INSECTICIDES SHALL BE STORED IN SEPARATE CABINETS AWAY FROM FOOD CONTACT AREAS. MENU fib — cxE3 pi O EQUIPMENT PLAN SCALE: 1/4 " = - DINING AREA TO SEATS 0 O 0 CO 18 PROVIDE GROMMET NOTE: SEE DETAIL 5/A6.4 FOR CABINET ELEVATION r ;C:VED PER PUBLIC VJC9 3 = .,r�� igp/ %7 MS % - 0002— Co 1155/USA IIJTE{?CE FFACL cITt O CT 0 2 190) PERMIT CENTER - - .,1 9 �( /� V 1,/` \/12 1 - - KITCHEN EQUIPMENT SCHEDULE - ITEr NO GENERAL Ory DESCRIPTION MA Uf ALlTA2Ek / MODEL a SJPRIER INSTALL GEN. REFRIGERATION LOMMENS FEEL RLFRGCRANT 1 SYSTEM PLUM6IN6 - cOMMENS - -. � STE CW N AFF i INDIRECT o IRELY - AFF i MECHANICAL Do4NST NNTTRAL 645 D LFM SP. BM PIPE - COMMENTS VOLTASE/A:ASE 2!_!„ LJAD KW - - -. NP ELECTRICAL Otb EGTION AFF P.IM HARD GOMMENTS ITE NO 3 4 N 0 1 D 9 10 N 12 13 3a 4 IS IE IF B 19 20 21 22 23 2 246 24< 34'"1 25 250 26 20 29 290 30 3 32 33 34a 3417 3 4c 346 350 INC 3 5c 33,1 356 3 31 53 39 40 4 410 4117 42 43 44 45 46 4 q8 49 A el 51 52 53 40 GALLON KETTLE W/ Ee'r DRAIN VALVE 8 STRAINER STAINLESS STEEL KETTLE HOOD BAGEL OVEN (GAS) LAY TABLE (24 PAN OVEN) 96 "X2 1/6' % 43 - /9 "N. SEMBLT NAL H05E ANGLE t HOOK1 BAGEL NROX 1 39 H PEEL HOLDER 39' x -I /4' X 31'H. SPEED RAIL COUNTER TOP 2 COOKER/VIARMER I PROP. TABLE eh' BO I' X T' 55 SHELF WALL HUNG ... O NOT USED I HAND SINK WITH FAUCET HAND INK H FAUCET WALK-IN COOLER NVL16NTS WALK-IN REMOTE CONDENSER -_. CKEVEL� LO EN HARDWARE 6kOUP z6 2 HGN (CUSTOMI BAXTER (ONLY) 610,18500-6124 FAB-N 5CUSTOM x2933 FA13X +CUSTOM ..y 15TOM - -_ - pROW'M1E EAGLE a 12 O EAGLE EAGLE E QUIP GC NSF AG A 000 6L. = QUIP 0000$ __ - - - -- -- -_ -- :QUIP GL . -- • QUIP -.. -' GL -- EQUIP. - EQUIP. G6 - _ - EQUIP. GL. - - -- :.- - ___ EQUIP 6 G i EQUIP GC. _- i _ -- EWIP bSC. _. _- EIXJIP PG. - UL /C5A - -- -- -- _ . -- - - -- _ .. - - -- - -- _. - -_ _- -.. -_. - _ " "" - -- - -_ - - - -' _ . -_ -- • -. -_ __ - --- AR COOLED -- FALCEi AS OCLOCK A RO TIN 6 LID T T1- OFF FURN T ' O W VAPOR TIGHT FIXNREN SEE DETAIL 10 /460 - RIGHT SIDE DRAIN LOCATION --_-.- WIT E x KFLOIW PREVENTE LOCATION - - HEO BAK OF T W TO BE ATTACHED TO BACK _ -.- -- _ - - -_ - VERIFY MWNTIN6 HEIGHT CV _.. -.. INSTALL ABOVE PREP TABLE ®Hi0" APP. - -__ WALL MOUNTED IN COUNTER 6 TO INSTALL VINYL STRIP DOOR 2 HP COMPRESSOR LOCATED ON ROOF �� 1/3 _ -_ _- -- 02" __ -. - -- -_. - I/2' I/2' - -- _ - - -' -- /2 /2 I/2 - -- NH _. _ IB ___ - -- - -- 36 - -- V H -- -_ I _ - -- -- - -- - -I/2" __ _ _ -... -- -. - _- __ --- 1-1/7 -- I -I/2'• -- ' - -- „ 8 - -_ V IF. - -- _ -- PROVIDE VAC. BREAKERS, FLE %ISLE TUBING FOR W4TLF d BU4FF VALVE --_ f -� - - - FLEx DRAIN LINE FRO VDE HOOK &4LKFLOW - VfNIER O VER FY MOUNT _ -. -__ _ _- -- _.. -._ - -- -- - -- - - 12 x 10 1400 / IF. -150 - -. - _ -_ _ - _ - __. __ 140p - -- - -- 25O NOO - -- - 3 /4' 15" PROVDE FLE%IBLE 645 PIPE _ - - -- - -- - - I° V F - ... _.. - __ _- - -- - - -. 1200 1200. 1200. I� - -- __ 1201. IC ... -.... __ - - -- 1200. 10 SOD.. 3m 100 - -- . 120 -_ -_ ... - -- __ 12 I!5 84 --- -_- - - -_ .. - -- -_, NO 9 Il0 15.0 1 20 8A - -- - - --- - -- -- -- -- - -- ._ -. ... - -- - -- - - -- -. - -- - _- - _ -- - -- -- - -- --- ._ _- ..- - -- __ -- -- -- - - - -- - -' _- ( __ - - -- - _ - -_ --- - - --- - -- _ -_ - _ - - - - -- 4 pROVlDE 3PST DIAONNELi SWITCH, NEMA - - -- rvIRE a L _ F-1XNRE PROVIDED WITH SOD Wn.ET T V. F. E K KIH 0E SPST AN O RU 2 HAU5T FAN F N WyEN ?hM1 15 OPERA , -. • - - -_ . -- - -_ -_ - -- - -- -_- -- -_ - -- V I. F. INSTALL LIGHTS !MAKE CONNECTION TO SNITCH - PRO VIDE A 50A. 5PW DISCONNECT O SN TCH _- - FAN UilL - -- V F. C ROVIpE 5P5 WP AO NECT SW T. 6 0 RE5SOR NTROL WR NG TO COMP - - - --- - -- _... -._.. _.. - - -_- -- - - - -.. -.. . -_ PROVIDE 5P5 DISCONNECT SWITCH PROVIDE 1100 --- ROWER FOR STAY I SOLENOIDS W/ L LD PAN PROVIDE 5P5T C SCONCE S IIOV POWER FOR - -- V F i 5TAT5 TO BE INSTALLED BELOW WINTER - VI F T -5TAT5 TO BE INSTALLED BELOW COUNTER -- V F PROVIDE 5PS DISCONNECT F WITLN _ - __,l' !; ' - ROV D 50LATE T b RW WR ETT EN TLEi b V F PROVIDE 5 RAE SNIT HER ET LEX O L E NO SNITCHED DUPLEX W Nr IA6WAlOV 1 2 5 P 13 13a 14 - -. -- 21 23 2`17 2417 24c 244 26 27 2B 29 290 -- - - -. -. _ -- - __ - -- - ___ _ - -_ __ -- -__ __ - _ -_- -_. - . - -__. # MAS -IOF - _ -- _ 12' 12" PROV DE CHROME ANGLE �11l9FF W4TCR _ -_ -- - -- - CORER PL '... - -- _- - -- N IIEN OKAY WHE0PCONCEALED NG - - _ - __ p.p%II X 8' -3 -3/ ,LPAK aPR 195M -OP EWIP • .. . EQUIP. 10.0. 1 1-- - EQUIP. G.G. EQUIP. 6L. -- - -- - -- -_ -- -- - _ _ -- -- -- _- _. _- -_- R -22 - -- -- _ _ -_ - -- -- V.IF -- _ - - - - -- WALK-IN FAN COIL _ 3 WALK -IN STORAGE SYSTEM 3- COMPARTMENT POT SINK 2 4' X 4 p STORAGE I N N O N I N N -_ -- -_. - -_ 1 BIB STORAGE 4 STORAGE SHELVING 2 LOOKERS (2) TIERS I GOAT RACK FIRST AID CABINET I DROP IN OL AN DROP -IN co. PAN aWK2T00 METRO-0 1E0GLE - -- SEE PLANS FOR SIZES 6 QUANTITIES ADD- x300119 PRE-RINSE FURNISHED 6 n301109 ADD -A- FAUCET FURNISHED WITH SINK - -- -_. - -_ - -- I/2" - I/2" __ -_ -_- - -i - - _ -- -- I" - -- 1 -- PROVIDE I' CANDENSAS DRAIN LINE i0 WTSDE OF COOLER TO INDIRECT GRAIN __ -- _ _ - " "- IISV AA W __ _ -_ - -- --- -- - -- - - - -- - - - - G514-16-3-15 EQUIP ' G L. 16 3 -I8 DJObNARD EWIP GL - - - - '.. PL • PL. - -- - -_ ... ___ _- - - IB' - -- 36' -_ -_ _ _ -- - -- -- -- -. _- � - -_ - - (3) 2' - -- 3" V F - -- -_- __ __ - - -- -_ T __ __ - -- -- - - - - _ - _ - - -- _ -_ - _ -_ - -- - 60° AFF PROVIDE ACID WD. BLOCKING IN WALL -- -- -. - -- FLUSH DIRECT WASTE CONNECTION W/ F TRAP - __- _ - __ __ PEPSI 1 OTIgRS _ - -. -. _ _ GOLD -POND EQUIP _ -p CORN EQUIP OTHERS - -_ G.L. bc _- GL. - PROVIDE 3' PVC CHASE FROM ITEM 19 T0 ITEM BI. _ - - -.. _. -. SEE PLANS FOR SIZES 6 QUANTITIES 6 G TO SECURE TO WALL _ - - -.. -- -. _._ __ -__ - -_ _ _.._.- _ - - - ... -_ _. -__ _ - -__ - -- -__ ___ _ __ T - I" I" - - - a 155MLOILAL .EWIP. 6L. _- 6. C. TO SECURE TO WALL - ._ _ - __ __ __- _- IIOV. I/� IIW. I� INC I. 10 IISV. (� DELFIELD a 5I45 -3 EQUIP. 6L . - -- '-' ___ "" E0 -0. I� 0,A TO PR OVDET T 6 SOLENOID VALVES WITH DROP IN COL PANS V.I.F. V F -- - - -- - -- DELFIELD F <818T -b 1 EQUIP. S.C. - - -- - -- ___ EQUIPMENT SUPPLIER TO PROVIDE i1�R1AOSTATS a SOLENOID VALVES WITH DROP IN co. PANS. - -- - - - - I REMOTE CONDENSER FOR DELFIELD a PAN L LA ED ON ROO DROP IN QUID PAN ' �„ 6L. GC. R -1344 AIR COOLED 1/4 HP GOMPRE5SOR -_ - -- _ -_ __ _ -_ - - - -- - -- -- - _ - 1 REMOTE CONDENSER FOR P IN L D a PAN LOLATED ON ROOF DROP IN GOLD PAN GL . bC . 64. 1 - -- - -- _- _ __ - -- 5-154A - -- AIR COOLED -_ _ -- I/O HP COMPRESSOR -- - -- - -- - -' - -- - - _ -- -__ -- -- - - - I DROP CASEWORK CUSTOM PROVIDE CUT -GUTS FOR CRUMB SWEEPING -- -- _- - -- _- _ -_ 1 _- - _ 2 • CUTTING BOARDS 3 MAGNETIC KNIFE HOLDER RIGHLITE L. 6 6 i MAGNABAR 6. L. GC. - _ DISP LO q FLASE, SELF-WN S E •SERVE, REgR LO 3 ASH RESISTERS BABEL RACK WITH LIGHTS FEDERA EWIP. GL aR %55L i - V.I.F. AIR COOLED 6L TO PR BASE, SE VY6 D ON �iILPL 6RAINHi 062 � P. LAM PPf£L t0 BE PL -I ED -- - -- _ - - 1 � 1 IISV. 19f ow. . 0 1200. 10 i BAKERY AUTOMATION PACKAGE 0T '''''CRS LR5 ~ - - -- _ -_ - - -- - - -- _ - - -_- _ _ - EWIP. - -.- IISV. I� IISV. I� - 2 43' WORK TOP FIGERATOR l OCA LL TAR FPB-% aLU5TO EQUIP. EQUIP. 6C. G4 - - -_ - -- - -- -- -- -' -- --- - - - - - REMOVE W dPLWS PIRNISNC WNNIY5 PROVIDE _ 1 ,, WATER TIGH 56F 5 LORD, LORD LAPS, WNST STAINLESS 51'cEL SQUP2EVERAbE TABLE 12' X 32" X 41'N _ - 2CJP HOLDER ON RISOS 6 WARMER ON LEFT _ . -. -- - - -_ COA LOUT 3�R IN TO FLOOR SINK BELOW. PROVIDE VALVE AT UNIT. - - - - - - -- -- - -- .. ROV DE 304 3P F WP DI5GONNECT SWITCH 5 . 28 CONNECTION i0 CO PANEL 6 OVI2 _ _.. - -- _- __ -_ -- • _ -- .2B PROVIDE DUPLEX OUTLET - -- _ - - -- - _L PROVIDE OUTLET .._ 2 WITH3 NE NINA OUTLET 8 i0 PRO GRD OW LD u 4 :OP PLW - - /10 6 1/I O 9 DL -- 020' PROVIDE SIMPLEX RECEPTACLE - -_- - -- - -- _ -_ -. - -.. _ _. -- -..._ - - -.. 32 34a 340 3� 35o 3k 3� 35e 36 40 - -- 41a 4117 42 43.. 44 - 41 48 A 551 51 52 53 I2 21R1.71 .x # m s 2 ml m sle Q § �, STAINLESS STEEL COFFEE TABLE TB X 32 41 0 '... NOT USED FAB-X aCISTOM EQUIP. GC . - - -- - -- - -- _ -_ WITH 12° X 4-1/2° INSET DRAIN 6 3 GUP HOLDERS ON RIGHT e LEFT -_- -_ I I" -. - V I.F. CONNECT 1° DRAIN INTO FLOOR SINK - - - - - - - -- - - -- - - -- -.- - _ -- - -. _... .- - -- -- -.- - -- • -_ - - -._ __ __ _ Ir7 -- _ _ -.- - I • STAINLESS STEEL PREP SINK EAbLE a x41422 -I -24 OCT WI . 6C . - -- - -- - -- - -- _ -_ W/ EAGLE a 500116 FAVGEf SINK FOWL ON RIGHT, DRAINEOARD ON LEFT _ -_ I - -- I/2 -_ - -- 1 V IF. _ SO " LONG SINGLE BAY NV 2 4' DRBD. - - - -- - - - 119 - -_ 15.0 • - -- 20.0 .- - -- - -- I SOUP WARMER WELLS EWIP. 6.G. NSF _ -_ UL _ -_ - -- 1/ 2• -_- 'tr. PROVIDE CWM BKER d '81.77.2.` VALVE WITH VA 3/B' MAL REA RARE __ __ _ _ - - _ 2 000 . m 0 : NOT USED - -- __ 1200. 10 - - 12OV. IC I ICE TEA MACHI NE - -- NOT USED __. -��- 2 MICROWAVE I HATCO TOASTER -. EWIP. GC - I/4- _ v!!!0! R GW 9.�P TO E�gAP 1 r FROM _ - - - - - - __ __ -_ _-_ _- _ -_ -- -__ FUTURE ITEM - PROVIDE ELECTRICAL 7 TA/ SYSTEM 05561 -_- -_ -_ /4' - _ -_ - __ _- _- � _ _ SHARP aR-22 PT EQUIP. 6L. -_ ... _ -.. -_ - --- _ -- I - - -_ ___ -_- V F -_ - - -1 _- - -- - - TA 100 -ERA --- GL. - r '- -_ -. -__ - - - -- - _ - V.I pB 4 _ 120 /2400 1m 12W. 10 - __- - _ -_ -- _ _ _ _ -- _- - - - -- -- -.. ^ V O� -_. 150 _.__- 30.0 150 - -_ -_ _ _- _ - -- -_ -_ _ -_ - - -- - -- __- -._ • O NOT USED COFFEE BREWER W/ WAI� FILTER 1 COFFEE GRADER CONDIMENT TABLE ' 'TR45W - BMN a WALE dUNN- O+tATIL 69 -2N0 _- _ 011485 OTHERS - _ -_ ' _ -_ __ _ - - - - - -_ _. -- _ tb. G. TO INSTALL WATER RTR (BY ['THEIRS AND WATER LINE TO COFFEE EQUIPMENT _ - - - - _ OTHERS OAR - -_- ___ r __ _ -_ _ -- SEE DETAIL 1 /463 SEE DETAIL 4 /463 S EE D E T AIL 2/ 463 - -- - -_ - -. -_- __ MILLWORK GL. ' G.L. - .CUSTOM - -_ _ -_ -_- -_ _ _ .. _ _ __ __- L -_ __ - - - -__ - MILLWORK RECYCLE 5OUSTOM r T G L -- -.. -- - -- __ _._ T 0 NOT USED - -- 0 NOT USED '- NEWSPAPER RAG 14 TABLE BASES (28.5 " HIGH) - -- - -_ -. -- _. - -.._- MILLWORK -_ -_- a CUSTOM 6L. bc . - _ _. -_ -- _- _ -_ _ -_ -_... -__ -_ -_- -__ _ -_ -_ __ ._. - - _ - __ FALCON EQUIP. x60318 PORTABLE y - -- _ -_ _ -- - ... _ -_ __ _. _ _ ._ _ __ __ __ -- - _ 22 20' x 29 " TOPS T FALCON 30 SERIES I EQUIP. G.G. -. -. - - - .- 6C. TO ATT TOPS TO BASES -__ _. -- - -_ _ __ _ B TABLE BASES (4015" HIGH) 6003 WIP. 3E6-22. E SL. . -. . -- - -- - -- - -- -- __. __ - - --_ - __ - _ __ - - - -- - ... - -_ ._ -. - -- _ - - - -. _ -- C. 010 Nj E -- AP�RO - -- -_ -- - -- - - QC1_ 1 .__ -- _ -- __..- .- � C ' DI VT _ `- - -- - .. ... _ -_ -_ CITY NKWILA CI 1 1991 - _ - - - -- _ __- ___ -_- ____ CENTER_ EHMIT _ -__. - -- - _ .66 IRE VER FY REW MENTS WIN INSTALLER _.. -_ GC TO VERI POWER REQUIREMENTS W1 VENDOR 22 GNAIRS SAFE FALCON -- - - - - -- MLEUNN aGK3021 EWIP. EWIP. GC . _- - _- _ 6L. - --- 2V N X 205" W. X 17315" D. - _. - _ -_ -. -- - - -.. �.. -- _ - - - { - -_ MILLWORK OFFICE LLUNIERTOP aCUSTW ... - - -t - _ _ ... - -- _- ._. - -- _ -- _ _- - -- _ - SEE DETAIL 5/46.1 ,_T SEE DETAIL 4/A61 �- FRONT COUNTER UNIT _ RAILING OFFICE ADJUSTABLE 5HELF5 FARO: BENCH ! T. 24 BAR STOOLS DINING LEDGE IN DEEP) 6 PINING LEDGE EASES (40.15 NISH) _.. MILLWORK 6G. CUSTOM CUSTOM GC. MILLWORK -. GL. aCNSTO M 6L - - -T- GC. GL. _ - - - _. - - -- -_ - - - -.- �. - _ _ SEE DETAIL 5/A6.1 ._ _. .- _ -- __ - - FALCON < 034 -812 EQUIP. FALCON EWIP. a 0292 -2 G.C. 6L. -- - - ... - -_ _ -_ _ -_ _ -_ SEE PLAN FOR SIZES d QUANTITIES -_ - _ _ -_ -- _ -- - -_ - -- -._ . ". ... SEE PLAN FOR SIZES 6 QUANTITIES __ - - - _ _ -_ _ - 1 1 -' _.. -�_- - P 500 a 3800 SERIES aP9W EQUIP. OTHERS bL OTHERS - - -- --- - -- - - -- - _ - - -- - - _ - - -- - - - -- VERIF REQUIRED NIINE31 OF EASES WITH IL SYSTEM O SECA, ALARM SYSTEM 1 AE LOCATE ON SHELF OVER OFFICE COUNTERTOP - - _ - -- -_ _ __ - _ Tp BE SELECTED OTHERS 4 OTHERS - _ -_ - -- -__ - -- L -- _ _ 7- 2 BABY CHANGING STATION a KoAL BEAR CARE EQUIP. 6L . - - -- - -- -- - -- _ _- - -- - V I SOUTHCENTER PLAZA TUKWILA, WASHINGTON o 3 JCL' G1U7111IET MGM ® tt C6 �YcBM REVISIONS fl EEIlMEl[T 110 0 CT4 INC., DA. vergreen One, 10940 NE 33rd Plnce, Suite 202, Bellevue, WA 98004 (200) 027- 100 DRAWN BY KAL DRAWING NAME 9623133 DATE. 8/19/96 PROJECT NO.. 96251 SHEET A3.3 OF - I I I - KITCHEN EQUIPMENT SCHEDULE ITEM NO GENERAL WATER PLUMBING EMlAUST MECHANICAL ELECTRICAL Iro, - NODEL T 5 0/50250 REFRIGERATION POSTE COM MENTS NNIIRAL 6A5 5 LOAD C VOLTA6E?MASE '' .445 ' M rFLW x� Q1Y. 2 DE5CWPTION MANPALTIRER / 1 MOP HANGER TO 5E SELECTED SPPLIER EpUIP INSTALL GE11 6P5 a 6.L. 1 _ __ REl'RIbERANi . _ SYSIB -1 -- -.. 5 __ __ HW AFF - -_ INDIRECT __ DIRECT AM __ __ _ pJOT _ GM SP. B. RFE PPF _ - _ ' -- _ HP ___ __ HARD AF 1 __ _ __ __ - __ 54 55 56 , HIGH CHAIR TO BE SELECTED ._ __ ___ �_�� -�- ___ -_ _- _ _ - - . _ __ - - OA515 TONER .GLEANERS EGOLAB 1(0050 OTHERS - - - __ - _ __ ___ __ r __ _ O Nor mein . -- __ __ _ _ _ - - _ _ - ___ ___ _ - _ -- - -- - _ 5T -- 58 59 SB 59 60 bl 62 O I 0 NOT USED 6.L. OTHERS __. - -- - -- __ - - - - - - - _ _ -.. t LI H OLDER CUSTOM MILLWORK 6L 66. ___ - __ __ - SEE DETAIL 3 /Pb3 T _ _ - - _ - -_ __ COMMENT BOX ___ _. __ __ -.. ___ _ -_ - __ - _ _ _ ___ _ _. __ _ __ _ _ __ 60 RETAIL DISPLAY 01/53701 MILLrbRK 6L. 1 6L. __ -_ __ SEE DETAIL 4/A6.4 __ ___ __ ___ - - - - - - _ _ - . -- - _ ___ __ ___ ___ _ - __ _.___ _ • 62 64 NOi U5EO r -- 6L. -~ ___ 6L. __ T -_ __t_ - - - ___ ___ - 64 WA116COrTIN6 _ -- -- - -- SEE DETAIL I /Pb.l - - - t -... - FRP WAINSCOTTING as 6L. �._ - _ _ __. SEE DETAIL 2/A6.1 __ _ __ - - - _ _ - - __ ___ 65 66 61 6B 69 ��FILr R 1I- O6ROLP ORKRS OTHERS ___ __- -- ._- -- rE IG TIA INS O RMS T ANION S WI - V.IF. V.I.F. -- V.IF. Jpy MCGT WASTEYL- - URI E0 - - - - _- 2204.10 121 __ 65 21' BELOW COUNTER REF. McGALL STAR Rb _ E EQU IP. S.C. GL. - - - _- - -_ __ __ __ __ __ __ - - - - - - - 1154.10 60 __ __ t- - H5 °, ___ . -.- r15" - _ -- _ __ bb 61 69 10 I ESPR5506RINDE5R RINSE OMER+ OTHERS OThPS25 __ ___ __ __ _ -. - -. -- - -_ ___ __ _- _ - - _ - - - - IIOV.I0 5.0 ___ -_ _- I KNOCK DM L05050000 6L. -_ __ __ - - _ - - - - -- __ __ ___ -_ . -. -- 1 OPENIN TO B E CUT IN FIELD 01' 6L. ESSF50000 CABINET MILL1G75K (CUSTOM/ 6L. 6C. __ - __ __ -- SEE DETAIL 5/A63 __ __ ___ __ __ __ - _ _ _ _ _ - ___ __ ___ __ __ - _ __ ___ __ ___ ___ __ TO 1 HOT WATER HEATER SEE PLUMING ORA11IN65 PC. P.G. __ ___ _ -- ___ - _ -- ___ - - _ _ - _ _ _ __ __ r� I -_ 11 2 BARRAGE WANTED HAND DRYER SMOCK 1 0-309 60 6.G. ___ ___ ___ -__ __ __ __ ___ -_ - _ - _ 1154.10 ZO.O FOLLOW MANFAGTUERS RECD RECOMMENDATIONS FOR MOUMIN6 HE16HT6 - TI 10 14 T2 T9 14 2 4 2 MIRROR 10/55 FRAME SUR FACE MOUNTED SOAP DISPENSER BOBRIL(x 8 -290 2436 G.G. b.G. -- -_ -_ ___ -_ __ . _ ___ _ _ BOBRICK 56 4112 -- -- SURFACE MM. WASTE RECEPTACLE BOBRIGK 16211 6C. 6.C. - -- -_ ___ -.- ._. _ __ __ __ - -- - -_ - _ _ - _ _- __ __ __ 15 2 1 1/2'0 55 GRAB BAR BO0RIGK 166006 036 60. 6L. -- - ___ ._ ___ _.- --- SA TIN FINISH -__ -_ -__ _ - _ _ _ - _- __ _ __ ___ ___ ___ ___ ___ ___ TS lb 16 T6 T TB 19 BO HI 1 1 1/2°0 55 GRAB BAR BOBRILK 03-6606 0 42 6L. 6.L. -- - _- __ SATIN FINISH -_ __ -_ _- - - - _ - -- _ ___ ___ __ 2 2 j O 2 TOILET TISSUE DISP. DEL. ROLL BOBRIGK 16214 6L. 6L -- -- --- -- NON- LOCKING SPINDLE -- - - -- -- - - - - -" '- I - COQ is o LL01 SEAT BOBRICK 064221 6L. 6.G. -_ __ ___ ___ __ __ -- - _ _ _ _ _ _ __ - __ __ -_ _ NOT USED -_ - -- - - - -_ __ __ ___ __ -_ 34 `JIRFACE MN PAPER TOWEL DISP. BOBRICK 1&362 _ _ _ - - -- __ _ S ELF - SE¢VE BEVB2AbE GENTEF BOOTH INC. 180I60 01HER5 01HER:a __ - __ _ VERIFY RPMN -IN REQUIREMENTS W MNFR PRIOR TO START OF C016TR00TION __ __ (21 I/4" _- __ - _ _ _ - - - - 1154.10 V.I.F. -_ Ig __ 32 I ICE M A K E R 5 5200 -OFF I0T BOOTH INC. - C R Y S T A L TIPS �D61 0 0340001 E O M ° .. 60. - -- - - -- R-004A - -- AIR-COOLED I/2' - -- - -- V.I.F. - r15° J E W FY W9HANIFAMBERS SPELIFILAT1016 - - - - - - - - - - - 1 1 5 5 . 1 0 I� $� O NOT USED NOT USED - __ _ _- -_ . -- _- -- -_ _ -- __ - - - - - - - - - _ - - _ -_ - -- 83 ___ - - ___ -_ _ _ _ _ __ __ _ 04 _ 1154.10 � 1 15 B6 550050 INTERCEPTOR THERMACO &6 DIPPER MODE- x W200.15' 6L. __ AN4,L __ - -- FLIXY R-4 T 10GPM� V ATI NLY OWER PLATT j PLACE BELOW LOCATIOIPRD�IR. LLFA E e LOCATION - •: • W210K) - _ VENTED 41451E PIPE ME HERB SPECIFILARONS - - - - - - - W.F. - -- W 5 50 0GATIONS. I VERIFY REQUIREMENTS MFR 00 %- , _ - MI 9e, t000-, 1o;� _ I- = __ I -- T 0 i r■ !ter rr► . -- ,T, 2 1995 PERMIT CENTER } - BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON 3RUEEGGETO BAGEL O. REVISIONS A ADDENDUM P3 9/26/96 FERMI' REVISIONS - PUBLIC WORKS 110 AQCIIITECT4, INC., P.8. Evergreen One, 10940 NE 33rd Place, Suite 202. Bellevue, WA 98004 (206 827 -2100 • R €4117EBED age sl R- 1 , w ("SHARD O 0. 60 JT . ,: ° nenlNCrw, N o z g KAL DRAWN, 9623134 DATE: 10/1/16 PRO.IE6T 5/0, 96201 A3.4 OF BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUK'/ILA, WASHINGTON \I I REVISIONS �+1T T�1Tr�v �1 1r� 1Lilllllll(+a lll 4 110 APCf CTTn INC ' "`LISEENED T J f 5s t o I - E - „ EIHEIT .; GI-JA DRAWN BY KAL SHEET A4.0 OF .F.UE GTEIE 0 BAGELOd .. ®N 9613 Eqp NAME. IlT P -I\ L1 CHERRY T PROJECT NO 96231 in WD -- 1 WP -I BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUK'/ILA, WASHINGTON REVISIONS �+1T T�1Tr�v �1 1r� 1Lilllllll(+a lll 4 110 APCf CTTn INC ' "`LISEENED T J f 5s t o I - E - „ EIHEIT I PRINT DATE :I 08128196 1405 DRAWN BY KAL SHEET A4.0 OF .F.UE GTEIE 0 BAGELOd .. ®N 9613 Eqp NAME. IlT 8/19/96 . d. N. D PROJECT NO 96231 BRJE6GER'S STANDARD INTERIOR NEON SIGN VERIFY ERA, LOCATION W/OINNER \ l I DINING AREA - NORTH ELEVATION \. l SCALE: I/4" • I' - O" 3 DINING AREA - SOUTH ELEVATION SCALE'. 1/4" = 1' - o" CHERRY TRIM WD -1, P-9 O DINING AREA - EAST ELEVATION SCALE: 1/4" = I' - O" PROVIDE IDENTIFICATION SIGN FOR EACH RESTROOM PER WAG 51 -SO. — N WP -I P -5 P-9 SEE DETAIL 5/A6.4 FOR SERVICE AREA ELEVATION SEE DETAIL 2/A62 FOR TERVICE COUNTER ELEVATION ® DINING AREA / VESTIBULE - WEST ELEVATION SCALE: 1/4" = 1' - O' P -1 1 .,nom I -5 14'-0" X 4' -0" BULLETIN BOARD PER DETAIL 2/A6.4 I T - 5 T - 5 P - 5 BAIL AREA P-9 WINDOW PER DETAIL 6 /A64 CHERRY TRIM WD -I, P -9 P - I� I 1 CHERRY TRIM HO I, P9 HP RP-1 CITY OCT 0 2 1990 PERMIT CENTER PUBLIC CORRIDOR CORRIDOR SECTION METAL STUDS ATTACHED TO STRUCTURE ABOVE G 00 TO MIN. I" ABOVE FINISHED CEILING -- -- 5/8" TYPE 'X' 6 RB. EACH SIDE OF METAL FRAMING 6" 25 GA METAL FRAMING B I6" S.C. ALIGN W% EXISTING CEILING FIRE STOP ® CEILING TYP. 5/8" TYPE 'X' 6 W B. EACH SIDE OF 3 5/6" 25 GA. METAL STUDS 6 16" O C. EXISTING CONCRETE FLOOR BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON STAINLESS STEEL PANEL HEM NE DA. APPROVE — SILICONE SEALANT COVED EPDXY WALL BASE INTEGRAL DRIP N BASE STAINLESS STEEL DETAILS SCALE. NO SCALE 3 5/6" MIL. ® 16 METAL STUD BRACE TO STRUCTURE SUSPENDED CEILING PER FINISH SCHEDULE STAINLESS STEEL AT OVEN AND KETTLE HOOD F R.P PANEL AT COOLER SEE FINISH SCHEDULE 5/8" TYPE W GPO SCALE NO SCALE TOP OF OVEN COOLER OR KETTLE HOOD 4" COOLER PANEL SCALE NO SCALE I/2" 9/6 EXP. ANCHORS ® 24" OC. THRU GROUT 255. SECURED IN SLAB COOLER BASE DETAIL NOTE HOOD 15 FOR REMOVAL OF WATER VAPOR AND KETTLE GASES ONLY AND DOES NOT REQUIRE NEPA BULLETIN NO. 96 FIRE EXTINGUISHING SYSTEM. NO GREASE -LADEN VAPORS ARE PRODUCED BY THE BAKE AREA EQUIPMENT. SUSPENDED CEILING ® 10-0" AFF 60 51X60 "LX24 "H 5S NSF HOOD BOTTOM OF HOOD 1-4" A.F.F. SCALE I/4" = 2-0" SECTION @ FASCIA - OVEN OR COOLER INSIDE CUT51DE SECTION AT BAKE AREA PANEL EDGE DETAIL SCALE FULL SCALE 1 1/2" SCREED 11/N5F SET COOLER OVER COVE RASE. INSTALLER EPDXY FLOOR TO SECURE SCREED RI/MFR. SUPPLIED TO CONC. FLOOR SEALANT UNISTRUT SUPPORTS YIELDED 55 DUCT LIGHT 1-IXTURE OVEN SOFFIT WALL SEE DETAIL 5/55.0 SUSPENDED CEILING AT 10-0" AFF. STAINLESS STEEL SOFFIT FROM TOP OF HOOD TO CEILING REVISIONS APE. 5" CHERRY TRIM P -I 3 5 /8" MIL. STUDS ® IS 0/G ANCHOR TO FLOOR CHAIR RAIL MARLITE PLANK 5/8" GYP. BOARD EACH SIDE 6' CERAMIC BASE DINING SIDE NOTE ALL CHERRY TRIM TO BE STAINED TO MATCH MARLITE PLANK AND FINISHED W/ 2 COATS (MINIMUM) OF SATIN FINISH POLYURETHANE. HALF WALL DETAIL SCALE: 3" = I' -O" NOTE : PVC FITTING TO PROJECT I" PAST P IJFRP CAULK JOINT VI/CLEAR SILICON CAULKING. (USDA APPROVED ) PAINT EXPOSED PVC TO MATCH FRP SCALE: 3' = IS" TO FINISH FLOOR SODA LINE CHASE DETAIL FLOOR DRAIN DETAIL SCALE: 3/4" = CUT CONCRETE FLOOR AN REQUIRED AT FLOOR DRAIN PLAN PITCH TO DRAIN I/4° PER FOOT 1 SECTION - _ I" X CHERRY CAP. FINISH 5AME AS CHAIR RAIL SERVICE SIDE RUN PVC PIPE UP TO CEILING GRID LEVEL. 3" SCHEDULE 40 PVC PIPE ANCHOR TO STIUDS 3 5/5" METAL STUDS MEfflE][T 4 110 CHITECT89 INC, P "fie TO STRUCTURE ABOVE CEILING SPLINE BRACING SCALE. NO SCALE SUSPENDED ACOUSTIC CEILING TILE VARIES - REFER TO CEILING PLAN BELT SIGN APPLIED TO FACT OF SOFFIT '1 -10 I/2" ALIGN W/ EXISTING SOFFIT a STOREFRONT. VERIFY HEIGHT IN FIELD SOFFIT DETAIL SCALE: I" = I' -0" SUSPENDED ACOUSTIC CEILING TILE IN FIELD. EQ. V VARIES - REFER TO CEILING PLAN NOTE: BRACE TO STRUCTURE AS REQUIRED. BELT SIGN APPLIED TO U FACE OF SOFFIT W' -10 I/2" ALIGN W/ EXISTING SOFFIT ® STOREFRONT. VERIFY HEIGHT SOFFIT DETAIL SCALE: I" = I' -O" Evergreen One, 10940 NE 33rd Place, Suite 202, Bellevue, WA 98004 (206 029 -2100 DINING AREA INSTAL 5 12 GA. VERTICAL WIRE AT V 0" S .C. CONNECTED TO MAIN RUNNER AND E ,OUCTURE ABOVE. INSTALL AN APPROVED COMPRESSION POST FLUSH WITH TOP OF CLG. LAID AND STRICT. ABOVE. SPRING CLIP CROSS RUNNER (INTERMEDIATE DUTY) --- — INSTALL 4 12 GA. WIRE CROSS BRACING IN EACH PLANE OF MAIN RUNNER AT 12 -0" O.C. AT 45 DEGREE ANGLES IN BOTH DIRECTIONS UT 0/STUNS WITH THE FIRST POINT WITHIN 6' -O" FROM EACH WALL. ..IN RUNNER (INTERMEDIATE PUPS NOTE: I. INSTALL AS REQUIRED UNDER 1114 UDC STANDARD 25 -2 2. SUPPORTING WIRES TO BE GAUGED AND SPACED PER 1994 UBC TABLE 25 -A 3. PROVIDE LIGHT FIXTURE SUPPORT ATTACHMENT PER 1994 USG STANDARD 25 -2. Tu . E16IS5ENEDg:I. 1/9¢1IIE14 . RICV:,1RB 0. FREIHEIT STALE Of WASHINGTON BRACE AS REQUIRED — SOFFIT FRAYING RECESSED LIGHT FIXTURE PER PLAN DRY WALL SOFFIT _ DTLMIOOI - - - SOFFIT FRAMING RECESSED LIGHT FIXTURE PER PLAN DRY WALL SOFFIT SERVING AREA rvEo CITY IUKWITA OCT 021996 PERMIT CENTER DRAWN BY. SHEET F KAL d v DRAWING NAME Q /0 9625060 A E a BATE Z p 8/19/96 LU H PROJP.CT NO OF 96230 I I I I I I I 7) m I C v, , —I" SO. STEEL PAR- I o -s 44 5Q. STEEL BAR 1 1/4 50. STEEL BAR BALUSTER PRIME 4 PAINT BLACK I BASE CAST IRON «202 PRIME 4 PAINT BLACK SCALE I/2" = I' -0" ADJUSTABLE P -LAM SHELF ALL SIDES (PL -4) 4" BACK - SPLASH — I I/2° P -LAM COUNTER (PL -21 SECURE TO 3 WALLS SEE FLOOR PLAN NOTE VERIFY SAFE HEIGHT PRIOR TO FABRICATING. SECTION @ DESK GROMMET HOLE PROVIDE ACCESS To PRONE H ELEC. OUTLETS IN WALL OPENING JAMB SCALE: HALF FULL SIZE —NEW WALL CONSTRUCTION PER SCHEDULE STAINLESS STEEL FRAME W/ WELDED CORNERS 2% BLOCKING SHIM AS REQUIRED SECTION AT MOP SINK MOP SINK 5 /9" 67P. END. ON MTL. FURRING N BOTTOM OF STRUCTURE ABOVE. MTL STUD WALL TO STRUCTURE ABOVE I LAYER 5/6" GYP. BRD. CEILING LEVEL SEE SHEET A1.0 UNISTRUT SUPPORTS AND HWH PLATFORM AT NP -O" A.F.F. MTL. STUD PLUMBING WALL MOP HANGER N +5-O" APE. SOAP DISP. MIRROR P-2 PAINTED GYP BD. ELEVATION NOTE. I. ALL TOILET ACCESSORIES PROVIDE AND INSTALLED ST 60. 2. SEE SAT. A3.I FOR ACTUAL ROOM DIMENSIONS AND WALL CONSTRUCTION 5 PROVIDE SOLID WD. F.T. SLOG. CONCEALED IN WALL FOR WALL MTD. FIXTURES SCALE: I/4" = 4 INSULATE EXPOSED PIPINT UNDER LAV. SECTION B SCALE: FULL -S- STRAIGHT LAMBS TONGUE #4428 5 STEEL PRIME 4, PAINT BLACK RAILING DETAIL SCALE: 11/2" = 1' -0" PLASTIC LAMINATE WAINSCOT (PL -3) TO .54° A.F F. SEE SHEET A9 FOR PLAN. PROVIDE ALL NECESSARY TRIM FOR COMPLETE INSTALLATION. GRAB E ELEVATION I. INSULATE EXPOSED HOT WATER AND DRAIN PIPES. 2. WATER RESISTANT G.W.B. TO BE USED ON ALL INT. RESTROOM WALLS AND CEILINGS. 3. PROVIDE EXHAUST FAN CAPABLE OF EXHAUSTING I COMPLETE AIR CHANGE EVERY FIFTEEN MINUTES. 4 INSULATE ALL PLUMBING LINES ABOVE SLAB. 5 RESTROOMS TO MEET ALL WA. STATE REGULATIONS FOR BARRIER -FREE ACCESS G. PROVIDE SOUND BATT INSULATION AT ALL RESTROOM WALLS. TOILET ROOM DIAGRAMS HANDRAIL MOULDING +4428 STEEL PRIME d PAINT BLACK NOTE: VERIFY WITH OVERALL LENGTH PER PLAN TOILET PAPER DISPENSER I I/4° x I/2" STEEL r BAR STOCK PRIME 4 PAINT BLACK BABY CHANGING STATION WELD AND GRIND SMOOTH ALL STEEL CONNECTIONS STEEL HANDRAIL, LAMBS TONGI.f 4 FLOOR FLANGE COMPONENTS BY JILIUS BUM a GO. PrN 800 -526 -6293 OR EQUAL CORE DRILL CONCRETE 4 TILE. USE NON - SHRINK ANCHORING CEMENT ALUMINUM 9O OUTSIDE CORNER SCALE: 3 = 1' -0" SCALE: 6" = 1' -0" CLEAR SILICONE SEALANT CERAMIC TILE BASE FINISH FLOOR SECTION CHERRY TRIM STAINED TO MATCH SEATING AREA WAINSCOT MARLITE BORDER 8-105 BLACK 4' FRP BORDER MARLITE SYNNETRIX 5 -10O 544 WHITE FRP PANEL WITH 4" X 4 SCORED PATTERN PLANS MARLITE WHITE J MOLD CLEAR SILICONE SEALANT CERAMIC TILE BASE (TIP) SECTION FRP WAINSCOTTING DETAIL STANDARD MARLITE ALUMINUM CORNER TRIMS ALUMINUM I35 OUTSIDE CORNER / CHAIR RAIL & WAINSGOTTING DETAIL ALUMINUM ITS INSIDE CORNER B � OD NHSd I � �TVBOFE EwI�A OCT 0 2 1990 PERMIT CENTER 5 3 BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON REVISIONS Y DEIHEIT Ho APCHITECT4, WC P. Evergreen Oue, 10940 NE 33rd Place, Suite 200 Bellevue, WA 98004 (200 827 -2100 0)1 /I n ,� °i Q 6 O DRAWN BY KAL DRAWING NA 9623161 DATE: 8, PROJECT NO 86257 SHEET A6.1 OF 3/4" PINO HINGED DO WITH LOUVER PANEL 00099411691)0 O FRONT COUNTER PLAN SALE 1/2= I' -0° PLASTIC LAMINATE - > , A� TERIM COUNTERTOP AND FASCIA (PL -2) AIM TO DISPLAY Tl l F O FRONT COUNTER ELEVATION SCALE: I/2"= 1' -0" ADJUST SHELVES 1 1/8' 3/4' END PANEL SCALE, I/2 N I' -0" 2_O SHELFF BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TULKWILA, WASHINGTON 3 ._ 2 , EXPRESS CABINET GASH LABINE11 CASH GAB1 SEE CABINET µ1 FOR 31114 59003 GUARD REAR ELEVATION OF FRONT COUNTER RETURN LAMINATE FASCIA FULL LENGTH OF END PANEL DISPLAY CASE r CHERRY TRIM 30' -T 3/8" PL -I 9- PLA5TIL LAMINATE)PL-2) FRONT PANEL AND TRIM -__ BULINOSE CUT 1701511 O MATCH BOTTOM OF DISPLAY CASE- 3/4" END PANEL SEE SHEET MB FOR ESPRESSO CABINET DETAILS. TRAY 5TORA6 06? STORAGE I ii) REAR OF DELI WRAP AREA CLOSED OFF WITH 3/4" PLYWD. COUNTER BELOW REMOV 16913) TILE BA53 I3ibOE • MONITOR PLASTIC LAMINATE (PL -2) COUNTERTOP 12' -0 I/O 11.-2 MONITOR GUARD PLASTIC LAMINATE 7 COUNTERTOP (PL -2) HI/ CHERRY EDGE CHERRY TRIM L- GERAMI I TILE BASE *A�5EMIG TILE — BAG STORAGE 101/2 131/2 -'_ I® • 11M■ DISPLAY CASE ■■I TRASH BAGS CUPS PLASTIC. LAMINATE ON PLAID SUBSTRATE BUILT U' TO PROVIDE EXACT 2' DEPTH INDICATED AT CHERRY TRIM. PL -2 CHERRY TRIM PLASTIC LAMINATE ON PLANE, SUBSTRATE BUILT UP TO PROVIDE EXACT 2 DEPTH INDICATED AT CHERRY TRIM NAM PL -1 PLASTIC LAMINATE ON PLAID SUBSTRATE BUILT UP TO PROVIDE EXACT 2' O0TH INDICATED AT CHERRY TRIM. PL-I T-5 V.2./ SECTION @ PRINTER STATION SCALE. 1°=1' -0' PLEXI. 66,409 MONITOR COVE 3' DI Le PLASTIC LAMINATE ( -2) COUNTER AND MONITOR GUARD CERAMIC 1ILE KICK SPACE RECESSED AREA AT THIS CABINET SPACE ONLY 1/4' HARDBOARD DIVIDERS B'Wx8'W 409441 INTO ADJOINING TRAY SPACE ON OPPOSITE CABINET WALL DOOR W111-1 COINER PIANO HINGED ALL 5 A-P DIhEN510N5 AND NOTES @ @ SECTION ® GPU STATION SCALE: 1"=1'-0" PLEA-GLASS MONITOR COVER F G scam 1'=1' -0' SEE SECTIONS W AND 'B' FOR OTHER NOTES AND DIMENSIONS SECTION @ RECEIPT PRINTER RECEIPT PRINTER SLIDING SHELF WITH CHROME "C" PULL TRAYS ADJUSTABLE 5HELF 8"x8' LOUVER IRTO CPU CABINET T5 PL -2 PL -I PROVIDE SILICONE GAUL SEAL AT CABINET DISPLAY JOINT TYPICAL ,,1rrrlg���i .PL -1 WAIN%0T ON AGAINST CASE AND GUT BASE TILE GAULK JOINT TY? REMAIN. 1/ /I cICLAE3AL,,,L,015,FLUSH FINISHES WITH ADJACENT 6" CERAMIC TILE BASE BULLNOSE TO SEE DETAIL SHT. A654 FOR PLEXI6LA0S SNEEZE GUARD DETAIL PL -2 PLASTIC LAMINATE COUNTER ON 3/4" PLYWD. IN 2" CHERRY TRIM WITH CHAMFERED 3" 0 314' CHERRY TRIM Sill - /4'' PLAID. ALUM. EDGING FINISH FLOOR CERAMIC TILE BASE 3' -3 I/O " 3/4" THK. 0UT,BOARD RV 1/2' =I —I� I DROP -IN UNIT — 3 /4'PLYWCOD 1 , ELECT. TEL., _ _, T 6 CT LINES TR 3 lIIIIIIIIII I - 2'3 /4" ti 2' -3 I/2' 2 I/4' 4" PLYWOOD NAELE DIVIDERS (3 EQUAL SPACES) OUTLINE OF DISPLAY UNIT O SECT @ REFRIG. DISPLAY CASE Ib PL -2 2 I/4" 3' -3/2" 3'-0 1/2" 2' -3 I/2 1 1/4' 2' -0' 1 I/v I/O 5 I/2" PAN CUT-CUT - PLAT METAL STOP 4' p O� '� OUTLINE OF DROP -IN 3/4° PLYWOOD PLASTIC STOP FINGER HOLE REMOVABLE PANEL CONTINENTAL MFG µ4114 ELECT, TEL., 6 FREON LINES 2' -I I/4' FINGER HOLE MAGNETIC CATCH yoyafTrez CERAMIC TILE BASE © © SECTION @ SANDWICH /TRASH STATION 5650E 141' -0• CHERRY EDGE BAND SEE SECTION "E" FOR OTHER NOTES AND DIMS. PLASTIC LAMINATE COUNTER W/ CHERRY EDGE BEYOND 2 I/4 " TRASH SNEEZE GUARD SANDWICH CNTR END PANEL (Mre I /8'xl I/2" ALUM. STRIP SCREWED TO COUNTER EDSE -- CHERRY EDGE BAND 1/4" PLYNIOOD REMOVABLE DIVIDERS (4 EOUAL SPADES) (,11y OF T � 621\ Wf D O CR 9?6 O SEGTION ® SANDWIGH /STORAGE STATION F SCALE: " =1' -0" CIT Y DF TUKWINA O C T 0 21995 SHEET OF A6.2 .3 (UE((IIGEIR T 1M EMI, �o 8A EE IF REVISIONS IMEI[lEI T 4 110 APCHITECTT, INC, Poke Evergreen One, 10940 NE 33rd Place, Suite 202, Bellevue, WA 98004 (206 B 7 -2100 q DRAWN BY: KAL DRAWING NAME: 9623162 DATE: 8/14/96 PROJECT N0.: 16231 it q x THANK YOU � .LHERRY TRIM \ 'N �PL -I� \\ 7 fil£ RRY TRIM - 4, CHERRY LID HOLDER PER DETAIL PL -2 PL-I / / / 54 3/4" it .zip o - N CHERRY LID HOLDER PER DETAIL PL -2 f O 0 O 0 �n P) N - J 00 O CONDIMENT TABLE DETAIL SCALE : I" = I' -0" PLAN ALL OPENIN65 IN COUNTER TO BE POLISHED FURNISH WITH FINISHED BACK 4 SIDES AS REOUIRED BY FLOOR PLAN NOTE : FINISH BACK 4 SIDES AS REQUIRED BY FLOOR PLAN MITER ALL FOUR CORNERS I" RADIUS AT SPLASH CORNER TYPICAL FLAP DOOR MOUNTED WITH A PIN HINGE. P PROVIDE CHERRY STOPS TO FIT THE PERIMETER OF THE RUBBERMAID 4 3158 TRASH DIN THAT MEASURES 19 5 /8" X I9 5/8" X 28" CABINET TO BE CONSTRUCTED WITH TYPICAL P. LAM. (PL -4/ OVER PLYWOOD CORE, 201/2" 13" SECTION AT TRASH 5 OE ADJUSTABLE FEET AT ALL 4 CORNERS INSIDE BASE. P,96 -023 O TRASH/RECYCLE CABINET 4 SCALE : I" • I' -0" ODOR TO BE HELD WITH A MAGANETIC CATCH FRONT ELEVATION ROUTED COPPER PLATE 52 MEDIUM, WHITE CORE 7 HORIZON AND TOP HORIZONTAL CASE EDGES ARE P. LAM. DOOR TO BE HELD WITH A MAGNETIC CATCH MOUNT FRONT DOOR ON PIANO HINGE PLASTIC LAMINATE BASE, FL-3 NOTES, I. TRIM 15 ATTACHED IN/ GLUE AND 5 5/4` LONG FINISHING NAILS PER SIDE. HOLES ARE TO BE FILLED AND SANDED. 2. ALL WCOD TO BE FINISHED SANDED AND SEALED STAIN TO MA CHNMA LII TAE PLATE POLYURETHANE MITER BACK CORNERS OF CHERRY SPLASHES 5/4 X 3/4" CHERRY RAILS TO SUPPORT RECYCLE BINS ADJSTABLE FEET AT ALL 4 CORNERS INSIDE BASE. OF CHERRY TOP TRIM FLAN FLAP DOOR MOUNTED NTH A PIN HINGE. CABINET TO BE CONSTRICTED WITH TYPICAL P. LAM. PL -4/ OVER PLYWOOD CORE. 20 1/2" SECTION AT RECYLE VERIFY THAT DOOR WILL SWING OVER THE EDGE OF THE RECYCLE BIN /CHERRY RAIL AT / CABINET BOTTOM SECTION NEWSPAPER RACK DETAIL 2 SCALE . 0' c I' -0° NOTES: I. ALL RACK MATERIAL TO BE HARD CHERRY, =� FINEST GRADE. STAIN TO MATCH MARLITE PLANK. 2. RACK TO BE FASTENED TO TRASH RECPTACLE WITH FLAT HEAD SCREW COUNTERSUNK FLUSH. 1 5 BISCUIT AND GLUE ALL RACK JOINTS. 4. 2 COATS SATIN POLYURETHANE OUTLINE OF CASEWORK ELEVATION NOT TO SCALE) I' -II I/2' PLASTIC LAMINATE (PL -2) COUNTER TOPS ESPRESSO MACHINE GRINDER KNOCK BOX PLAN ® ESPRESSO CABINET 0 - LID HOLDER SCALE : 5° c SECTION (NOT TO SCALE) 'I VERICAL AND TOP MEE HORIZONTAL CASE EDGES ARE P. LAM. O A CATCH d NT FRONT DOOR REFRIGERATOR ON PIANO HINGE �OI m CHERRYEDGE BAND CERAMIC TILE BASE (TM.) [10 FRONT ELEVATION r I /6" FRONT ELEVATION NOT TO SCALE) PL -2 PL -2 PLASTIC LAMINATE COUNTER ON 3/4" PLYWD CHERRY TRI NOTE: SEE SECTION 'S" ON SHEET AGO FOR ADDITIONAL NOTES AND DIMENSIONS. 3 /8 °f1, 0 5/8" 3 5/8" 3 5/8" 3/0" 1/4° 1/4" PL -2 PLASTIC LAMINATE (PL 2) COUNTER / FASCIA ON 5/4° PLYWD. PL -I PLAN NOT TO SCALE) SECTION - A I-0 I/0° } SECTION - 5 NOTES. I. ALL MATERIAL To BE HARD CHERRY, FINEST GRADE, STAIN TO MATCH MARLITE FLANK. 2. TWO COATS SATIN POLYURETHANE. KNOCK BOX (TO BE CUT IN FIELD) ADJUSTABLE SHELF CHERRY EDGE UNDERC REFRIG - ' ' 'OR. VERIFY IRED C ES PRIOR TO CA' TRUCTION. 01011.1\ D OC1 110 NOTES: _ ��11���,,,- LIVIS)3N I. TRIM IN ATTACHED W/ SLUE AND 3 3/4' O B FINISHING NAILS PER SIDE. HOLES ARE TO BE FILLED AND SANDED. 2. ALL WOOD TOR FINISHED SANDED AND SEALED Crt vHP TUSWlLA STAIN O M ATCH MA K POLYURETHANE, OCT 0 ? 199E PERMIT CENTER o rk GGER'S MGM, Co M! G RR REVISIONS ]DEIIIIEll "I 4 110 AJ Cl1ITECTT INC., Poke Evergreen One, 10940 NE 93rd Place, Suite 202, Bellevue, MR 98004 ( 08 027 - 2100 l� /9 REGISTERED u- yGryi1 V/ " T F REIHE I -�� AS NO F Q m F 'S � fL O DRAWN BY: KAL DRAWING NAME: 9623'163 DATE: 8/15/96 PROJECT NO 96237 BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON Pal n +eNiESexi SHEET A6.3 OF I I I 3/16" PLEXIPLAQS MERCHANDISE DISPLAY. SEE DETAIL 4/A61 (11-1A (11-1A \ rP -35 y `� CHEESE BOARD R WITH CONEED CORNER SILICONE CAULK ENTIRE LENGTH PLASTIC LAMINATE 45° COUNTER (SELF EDGE) - �PL -I BEVERAGE BOARD A SOUP EOARD .6 SANDWICH EOARD 5 BAGEL/CREAM CHEESE BOARD 5 f 60" I 1n 1 n n n n n n n n n 0 v PLYWD. SUBSTRATE / CLEAR WASHER EA SCREW NOTE: NO JOINTS OOOURIN6 OVER FOOD AREAS. SNEEZE GUARD DETAIL SN EEZ _ — -�_ ' BOARD .0 -- Yk.-Za BD. #4 1 J BD. x2 N �-) 4" BLACK PRE BORDER I TRIM CAP v - SOAP DAP. �P -3 - S CHERRY TRIM � I. ....�l .... .�...... .. . .i® � 2 .dILIILI�III .-- ng I.III LIIL1him- II�.II uwit.E o o _ FERRY EDGE — � � • . ..... . ... _ e _ - _ ._.� - _ - I a1e., - . ..... 1 .... . . f .��I I......... . .. .. :. m.. _ SCALE: - = ...mm ,m�lmm�m....�. ��, o.........� �. . —�— �I�I ■III�ITIiI���lit�ITl!iiplil < CHERRY KNEES AND LEDGER — � - -.I- -� — i \ J �� , - _ _ _- _._ - 114-.1 4 II /4�� FABRIC COVERED HOMOSOTE .. \ - . .1 E) -- I , m IIIII I� .. .m . - REFAIG. REFRIG. I...t� I IW 1111111 mIMEN III ..... .�OV ER _ .i_ : l Ii ...mm1 �'.. .!Ii�mm... I........t ........1.. L........ ........I ._ ,vim - - - - - . .I _ -- - w--e --- _ - - -ce DISPLAY _ _ NOTE: ALL CHERRY TO BE STAINED TO I MATCH MARLITE PLANK. SHELF DETAIL - I I II II n \�� _ COFFEE TABLE T3 J INSET SOUP 4 BASEL RACK BEVERAGE TABLE BAOK COUNTER ELEVATION UI CHERRY TRIM STAINED I/2" MEEKS TO MATCH MARLITE PLANK. FABRIC TO BE BY "S NBREL A" COLOR: JOCKEY RED BULLETIN >ARD DETAIL SCALE: /� _ -O O O SCALE: NONE SCALE: I" = I' -O" O GASINET SPEGIFIGTION REQUIREMENTS sln "q T SERIES FG 1000 BLACK OR AN EQUAL. STAINED CHERRY Mg1LDING JAMBS 3 1/2 SEEE PE TA I 1 m BOTH - 36' RECESSED - ALL CASEWORK SHALL COMPLY WITH AIM SECTION 400 AND ITS DIVISION 4005 LAMINATE GLAD CABINETS;' CUSTOM GRADE, GP -50 FOR HORIZONTAL SURFACES, GP -25 FOR PLASTIC LAMINATE EDGES, GP -20 FOR SEMI - EXPOSED AND INTERIOR CASEWORK SURFACES. 2. ALL VERTICAL SURFACES TO BE AMA -RATED AC-X PLYWOOD, 3/4" THICK, OR X° EXTERIOR RATED "MEDE FIBERBOARD, 3/4" THICK. THE CORE MATERIAL 15 TO HE COVERED WITH VERTICAL GRADE PLASTIC LAMINATE ON ALL VISIBLE B. ALL HORIZONTAL SURFACES SHALL BE MARINE GRADE PLYWOOD, 3/4' THICK. 4. THE LAMINATE BOND TO THE SUBSTRATE SHALL BE ACCOMPLISHED UNDER PRESSURE WITH A WATER RESISTANT ADHESIVE. 5. ALL CASEWORK JOINTS SHALL BE GLUED AND MECHANICALLY FASTENED. DOWELS, LEMON SPLINES AND SCREWS ARE ACCEPTABLE MECHANIC AL FASTENINGS. STAPLES ARE NOT ACCEPTABLE. N. ALL CHERRY LUMBER AND TRIM SHALL COMPLY WITH AWI SECTION 100, GRAPE I, HARD CHERRY, PLAIN SAWN. T. HINGES SHALL BE PIANO HINGES, SATIN STAINLESS STEEL. 5 FINGER PULLS TO BE MAXIMUM I" DIAMETER, RECESSED, 1.526D FINISH. 9. CASTERS TO HAVE CASTERS. MARKING SOFT RUBBER WHEELS WITH BRAKES ON TWO FRONT CTER 10. ADJUSTABLE SHELVING STANDARDS AND SUPPORTS TO BE MORTISE MOUNTED, 5/8' WIDE X 3/16" HIGH X LENGTH INDICATED, BHM A No. 504011, ZINC- PLATED STEEL HORIZONTAL SLOTTED TYPE STANARDS CLOSED SHELF REST SUPPORT, BHMA No 864081, ZINC PLATED STEEL 11, SLIDING DOOR FITTINGS TO BE HAFELE "HANGAR SLIDING DOOR FITTING SYSTEM" WITH .40111000" (UPPER TRACK), 4401.13.906 (ROLLERS), 4 40101942 (GUIDE), STICK ON RUBBER STOP (MAXIMUM 16" THICK/. _ 12. PROVIDE METAL ADJUSTABLE SHELVING PINS OR RECESSED KV BRACKETS. PLASTIC SHELVING SUPPORTS ARE NOT ACCEPTABLE. MATERIAL SPECIFICATIONS: I. ALL COUNTER TOPS TO BE HORIZONTAL GRADE PIONITE "WHITE FIESTA" 445550 -5, SUEDE FINISH, 2. ALL PLASTIC LAMINATE ON VERTICAL SURFACES EXPOSED TO CUSTOMER TO BE SIMULATED WOOD GRAIN, VERTICAL GRADE, FORMICA 5904 -45, "WILD CHERRY ", ARTISAN FINISH. 3. ALL PLASTIC LAMINATE FINISHES ON CABINET INTERIORS AND SURFACES NOT EXPOSED TO CUSTOMER (IF. SACK OF SERVING GOWN TER TO BE PIONITE 55826 'ANGEL WHITE, SUEDE FINISH, 18, WINDSOR ANIGRE, 4. MARLITE PLANKS TO BE "WOODGRAIN COLLECTION PLANK' 5 SO WITH MATCHING EDGE ACCESSORIES. ALL CHERRY SURFACES AND TRIM TO BE STAINED TO MATCH MARLITE PLANKS AND FINISHED WITH THREE (3) COATS OF CLEAR POLYURETHANE. 5 SEE FINISH SPECIFICATIONS ON SHEET A9.0 FOR CERAMIC TILE BASE. v ,_,,) ,171 0).... 0 , 24 , 1, . „ 3 I MITRE CROWN AND DENTILS I BACK TO WALL TIT' STAINED CHERRY GROWN RY CRO - _ "ry ' - 1 / 2 ENDS A MOLDING AND I/2" TYPICAL O I r, BMA �' `: �I ' �� _ t B 11 BO TTOM OF 55 KETTLE r �-I/2 I" ry HOOD A VISTAWALL STOREFRONT. I ANODIZED FINISH B 1/4" SHIM TYP. DETAIL I" CABINET CAP TRIM TO BE I /2' STAINED CHERRY 1/4" THICK CLEAR SAFETY GLASS Q SILICONE CAULK 5.5. ANGLE JAMBS, APPROVED K i � � Y I/2" RADIUS QUARTER ROUND AT SILL AND A I TIP. '1 SILL , 8 HEAD 3 5 /B" MET. STUD WALL 5 /B FIRE RETARDANT PLYWOOD I STANDARDS KV- 255Z0:36" 3/4” SHELVES - v IIIIIII: I/2' �� �/ 1 I/4" SCREWS 6 " 0.G. Q I/O ' 5/5" BD. B GYP. STAINLESS STEEL 1 WALL PANEL m " „Ir v m STAINED CHERRY QUARTER -ROUND B Ul nT«' S c ro 15/4 ALUM. STOREFRONT TRIM BLACK ANODIZED FINISH IT 1 \ , /� / /� I_ L Y /"N'T O �t / \ �,>- L/ T l/ 0 I- �X /� ,1 —�9 _ _ P. LAM -.STAINED TRIM PL -I UNLESS SEE C1�� I � t `2 [\ \y pPF 1) 0 199 —A ;;o = 3/4" GORIER ROW A t-'l NOTE. ELEVATION I' -I" ALL SURFACES TO BE PLASTIC LAMINATE OTHERWISE NOTED. Ob 00 1 FOR PLASTIC SECTION LAMINATE TYPES. SECTION A SCALE: 3/4 " =1' -O" 1( \/ I/2 " =1' -O" O BAKE WINDOW DETAIL P ( H ° °E; TUKWILA CITY OCT o 21995 MEROHANDISE DISPLAY SHELF D ETA ILS 6 SCALE: AS NOTED I I q, O SCALE: AS NOTED PERMIT CENTER ow. .....,m BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON 0 0 EJJGGER°0 BAGEL S. C RA 1HH N REVISIONS PERMIT SET 6/20/96 � ¶��^�/�/ E��[7�IF p¶yJI�!9,1�pI7Ery�IIIIEII�� \NCI`/"" � T�10 d 11.DCffll rE-0C UL �.J°. ILb V ., l .8. Evergreen One, 10940 NE 39rd Place, Suite 202, Bellevue, WA 98004 (208 827 -2100 F fa O F ,p zS 0. KAL ✓ DRAWING NAME: 9623764 DATE: 8/19/96 PROJECT NO 46231 A6.4 OF LIGHTING NOTES: I. ALL LIGHTING SHALL MEET THE REQUIREMENTS OF THE VWSHIN6TON STATE NREC CHAPTER N. 2 VERIFY ALL ELECTRICAL CIRCUIT LOADS FOR NEW LIGHTING CIRCUITS. MAXIMUM OF 16 AMPS ALLOWED PER CIRCUIT. 3. ELECTRICAL, MECHANICAL AND FIRE SPRINKLER WORK SHALL BE BIDDER DESIGNED AND UNDER SEPARATE PERMIT 4 'Mr DENOTES NIGHT LIGHT CIRCUIT FUNCTION. 5. PROVIDE EMERGENCY LIGHTING AND EXIT SIGNAGE PER GENERAL NOTE *26, SHEET A0.0. 09b -663 BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON LIGHTING BUDGET GALGULATION KITCHEN/FOOD PERPARATION AREAS 1022 5Q. FT. = EXEMPT DINING AREA 1,256 SQ. FT. H 10 WATTS PER SO. FT.: 1,236 WATTS TOTAL WATTS ALLOWED: 1,236 WATTS TOTAL WATTS FROVIDED: 1.041 MATTE (2) SURFACE MOUNTED FLUORESCENTS H 40 W EA. = HOW (25) RECESSED FLUORESCENT CANS B 31 W EA. = 1152 (II) FLUORESCENT PENDANT FIXTURES H 51 W EA. - SHIN TOT SH REVISIONS NEW SUSP ACOIY. CEIIJNE H *11 -2 I/2' A.FF (ACT -2) BRACE PER DETAIL I /A6.0. O REPLEGTED CEILING PLAN SCALE: I/4 " =1' -0" B'-0 ES. r 'S r l gi ■■■I _ •••••••••••••• ••► I I11� ■ ■ ■ ■ ■■ III, :�mraxau.�i II..■■■■ ■..F E ■1 ■ ■ ■ ■ ■,O ■ ■ ■1 ■■ ■ III ' STEA WM" Ell •1 .TUTU g• r. ■I- GWB CEILING F� G -C AF STAINLESS STEEL FASCIA AT OVEN PER DETAIL 8 /AGO NEW SU5P, A es H 0-0" AFF BRACE PER D • d 1• 111111 mum. ■ ■ ■■ ■ _ ■ M■! B■ ■ ■I■■E' • .i N ■■■ ■1f41■ � i ■ ■E11■ ■■ ■111 ■1■i1■ NL ■■I1 ■. ii ■ ■■1� ■ ■■■ ■�I ■■ , ill ■II C ■■■■■■■•■ �■■■ ■ ■ OMEN IN ■III, C • •••••••••••1•••••• ■1■■ •� MII C ■r i \ii ■■Cd ■■ ■ ■■ ■ii■ I11 F■■ i•�7', ■ ■id. ■■ ■ ■ ■ ■ ■1••••••••••••••••• ■ i■ ■■ ■ - ■ EN1■ ■ ■ ■ ■ ■ ■■■■ . ■ ■■ M .■ ••••••••••••1111•••• •C ■■■■ A■■ a■■ ■■■.■ ■,11101115111111110111511111111011151111111111 ._1 ■11 ■ ■ ■ ■1 ■■ ■ ■■ ■ 1■U.■ 11 ■■■■■■ ■1•■■ 111•••••••••••••••• ■ ■■ ■■ 1■■ mmom ,9 ■m !■■ ...... ■■■■1■ ■ ..■ ■■ ■■•PUI..aIIiii • . 1111 ■ � � ■ ■ ■ ■ �� ■ ■ �� ■■ ■ ■■■■■IIII 1■ ■1 ■ ■ ■ ■ ■ ■II ■ ■ ■ ■ ■ ■ ■\1 ■■ ■.a■■ ..■■UI ■I.al ■ !■: ■I•IIE7�.1 ■II■ 1 N G■■■■simind ■■■ ■ 1■ ■1■■■ ■ ■■ ■■ ■■■■■ n ■ C � ¶��'�/�/ 1�![7���TE'B I T�I � � D � I T E TY' MEC' P. 1 C11I EC , INC., 1 NC P. 444 LOCATION FOR NEW LIGHT SWITCHES. CONTRACTOR TO VERIFY NUMBER OF CIRCUITS REQUIRED FOR NUMBER OF LIGHT FIXTURES SHOWN. Evergreen One, 10940 NE 33rd Place, Suite 202, Bellevue, WA 90004 (206 827 -2100 EQ. REGIS TERED 0 FREIN 1 ASNIi1 , w Fa E6 DRAWN BY KAL DATE: 8 /IR /R6 PROJECT NO.: OF 16201 1E CITY OF TUKWILp OCT 0 ?( MiA9I1 CENTER SHEET DRAWING NAME: A 7a® 2623130 /� LIGHTING FIXTURE SCHEDULE SYMBOL TAG MAWFACNTOR / CATALOG a LAMS TOTAL VOLTAGE MOWING REMARKS A B C D E TOTAL LIGHTING CONCEPTS a CUSTOM *LBI000 -12 -PL CONTACT: (10H) 449 -2022 (2) PL -IT SPATS 31 120 PENDANT CUSTOM FLUORESCENT PENDANT FIXTURE WITH GLASS BOWL LENS. BOTTOM OF FIXTURE SO" BELOW CEILING. HALO L650 -MB SERIES (TRACK) (U -500. PARHO/HIR/ FUSS ( H A L O GE W 50 120 SURFA MINITUBE TRACK WITH UNIVERSAL LAMPHOLDERS BLACK FINISH. PROVIDE ALL REQUIRED MOUNTING ACCESSORIES. WHERE CORNERS ARE INDICATED UTILIZE Y LIOE -MB FLEXIBLE CONNECTOR. h I I HALO A H1251 HALO HTH92 T2) ITN HIN TUBE (2) 1511 TWIN TUBe 31 120 RECESSED TWIN TUBE FLUORESCENT DOWNLIGHT WITH ALZAK SELF FLANGE LOW IRIDESCENT REFLECTOR AND ELECTRONIC BALLAST. 31 120 RECESSED TWIN TUBE FLUORESCENT DOWNLIGHT W TI ALZAK SELF FLANGE L RoescENT RCREcToR T. AND ELECTRONIC BALLAST METALUX • 26 332A 120 EMT EQ (3) -320. TH /SPX30 95 120 2' X 4' FLUORESCENT LAY -IN HITS ACRYLIC PRISMATIC LENS, ELECTRONIC BALLAST AND SAFE -T CLIPS. LAMPS TO BE 3000 K. RECESSED 1 a R9 MIDES 1 (2) 202 T -8 40 120 SURFACE 24" LONG SURFACE MOUNTED FLUORESCENT FIXTURE WITH CHROME TR114 I EXIT ( u ® SURE - LITES a EAX- 5000 -6 (2) -200 T6 -I/2 (2) -5.62. DO. 50 120 SURFACE EXIT SIGN WITH SELF POWERED BATTERY BACK UP. CEILING MOUNTED. G H i 0 C RE -CITES C -2 VAPORPROOF INCANDESCENT RAB 00100PG (2) -PAR 36 35 150 120 SURFACE BATTERY POWERED EMERGENCY LIGHTING FIXTURE WITH LEAD CALCIUM BATTERY, CAPABLE OF POWERING TWO (2) HEADS. EGGSHELL WHITE FINISH. (I) INCH 120 SURFACE VAPOR TIGHT FIXTURE W/ GUARD METAU)X RS 222A 120 MIS EQ (2) 320 TO /SPX30 62 120 RECESSED 1 X 4 FLUORESCENT FIXTURE WITH ACRYLIC PRISMATIC LENS. HIGH TEMPERATURE ELECTRONIC BALLAST. I F II METALUX *25 255A 00 E810 EO (2) FU40 61 120 2'X4' FLUORESCENT LAY -IN WITH ACRYLIC PRISMATIC LENS, ELECTRONIC BALLAST AND SAFE -T CLIPS. LAMPS TO BE 5000K ,, W / N RECESSED LIGHTING NOTES: I. ALL LIGHTING SHALL MEET THE REQUIREMENTS OF THE VWSHIN6TON STATE NREC CHAPTER N. 2 VERIFY ALL ELECTRICAL CIRCUIT LOADS FOR NEW LIGHTING CIRCUITS. MAXIMUM OF 16 AMPS ALLOWED PER CIRCUIT. 3. ELECTRICAL, MECHANICAL AND FIRE SPRINKLER WORK SHALL BE BIDDER DESIGNED AND UNDER SEPARATE PERMIT 4 'Mr DENOTES NIGHT LIGHT CIRCUIT FUNCTION. 5. PROVIDE EMERGENCY LIGHTING AND EXIT SIGNAGE PER GENERAL NOTE *26, SHEET A0.0. 09b -663 BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON LIGHTING BUDGET GALGULATION KITCHEN/FOOD PERPARATION AREAS 1022 5Q. FT. = EXEMPT DINING AREA 1,256 SQ. FT. H 10 WATTS PER SO. FT.: 1,236 WATTS TOTAL WATTS ALLOWED: 1,236 WATTS TOTAL WATTS FROVIDED: 1.041 MATTE (2) SURFACE MOUNTED FLUORESCENTS H 40 W EA. = HOW (25) RECESSED FLUORESCENT CANS B 31 W EA. = 1152 (II) FLUORESCENT PENDANT FIXTURES H 51 W EA. - SHIN TOT SH REVISIONS NEW SUSP ACOIY. CEIIJNE H *11 -2 I/2' A.FF (ACT -2) BRACE PER DETAIL I /A6.0. O REPLEGTED CEILING PLAN SCALE: I/4 " =1' -0" B'-0 ES. r 'S r l gi ■■■I _ •••••••••••••• ••► I I11� ■ ■ ■ ■ ■■ III, :�mraxau.�i II..■■■■ ■..F E ■1 ■ ■ ■ ■ ■,O ■ ■ ■1 ■■ ■ III ' STEA WM" Ell •1 .TUTU g• r. ■I- GWB CEILING F� G -C AF STAINLESS STEEL FASCIA AT OVEN PER DETAIL 8 /AGO NEW SU5P, A es H 0-0" AFF BRACE PER D • d 1• 111111 mum. ■ ■ ■■ ■ _ ■ M■! B■ ■ ■I■■E' • .i N ■■■ ■1f41■ � i ■ ■E11■ ■■ ■111 ■1■i1■ NL ■■I1 ■. ii ■ ■■1� ■ ■■■ ■�I ■■ , ill ■II C ■■■■■■■•■ �■■■ ■ ■ OMEN IN ■III, C • •••••••••••1•••••• ■1■■ •� MII C ■r i \ii ■■Cd ■■ ■ ■■ ■ii■ I11 F■■ i•�7', ■ ■id. ■■ ■ ■ ■ ■ ■1••••••••••••••••• ■ i■ ■■ ■ - ■ EN1■ ■ ■ ■ ■ ■ ■■■■ . ■ ■■ M .■ ••••••••••••1111•••• •C ■■■■ A■■ a■■ ■■■.■ ■,11101115111111110111511111111011151111111111 ._1 ■11 ■ ■ ■ ■1 ■■ ■ ■■ ■ 1■U.■ 11 ■■■■■■ ■1•■■ 111•••••••••••••••• ■ ■■ ■■ 1■■ mmom ,9 ■m !■■ ...... ■■■■1■ ■ ..■ ■■ ■■•PUI..aIIiii • . 1111 ■ � � ■ ■ ■ ■ �� ■ ■ �� ■■ ■ ■■■■■IIII 1■ ■1 ■ ■ ■ ■ ■ ■II ■ ■ ■ ■ ■ ■ ■\1 ■■ ■.a■■ ..■■UI ■I.al ■ !■: ■I•IIE7�.1 ■II■ 1 N G■■■■simind ■■■ ■ 1■ ■1■■■ ■ ■■ ■■ ■■■■■ n ■ C � ¶��'�/�/ 1�![7���TE'B I T�I � � D � I T E TY' MEC' P. 1 C11I EC , INC., 1 NC P. 444 LOCATION FOR NEW LIGHT SWITCHES. CONTRACTOR TO VERIFY NUMBER OF CIRCUITS REQUIRED FOR NUMBER OF LIGHT FIXTURES SHOWN. Evergreen One, 10940 NE 33rd Place, Suite 202, Bellevue, WA 90004 (206 827 -2100 EQ. REGIS TERED 0 FREIN 1 ASNIi1 , w Fa E6 DRAWN BY KAL DATE: 8 /IR /R6 PROJECT NO.: OF 16201 1E CITY OF TUKWILp OCT 0 ?( MiA9I1 CENTER SHEET DRAWING NAME: A 7a® 2623130 /� I I I - - MATERIAL AN COLOR 6CHEDULE LEGEND ROOM FINISH SGHEDL HARDWARE SCHEDULE SET DOOR NO. ITEM MANUFACTURER 4 MODEL 0 FINISH REMARKS REMARKS RM. NO ROOM NAME MI5 FLOOR WALLS _ CEILING REMARKS ALL DOOR HARDWARE TO THATCH THATCH EXISTING - -' QQ __ SYM MATERIAL MANUFACTURER COLOR AND /OR TEXTURE I NEST MAIL I HOT. E%15TING BUILDING STANDARDS. ACT -I ALT -2 -- FRP -I FRP -2 - -- FRF -3 FRP -4 A OUSTIGAL CEILING TILE WITH GRID H G II TIGAL AP ING TILE WITH WITH GRID - - R PLASTIC LA55 REINFORCED PLASTID (PANELS USA INTERIORS INC. ARMSTRONG R 3210 FIREGODE SQUARE EDGE GYPSUM CEILING PANELS WITH 2 -MIL. THICK WHITE VINYL FADING CL: R W l5 ", COLOR: WHITE, GRID: DOWN DIV. (USG INTERIORS, INC) Z%A ENVIROMEEXISTING AL GRID DOOLOR: : WHITE HITE 101 102 DINING AREA VESTIBJLE GWB 6118 5 -2, T- 5-4 ACT-2 GAS O^ FIT a 01. 10 1/2' TO BE P -I ALIGN W/ Ex +12-2 I/2' -. -- - - -___ '- - SECOND LOOK 1 0 2165 SIZE 24 "x48' TILE WITh 'sI SCORING DOLOR: WHITE, GRID: ARMSTRONG PRELUDE IS /I6" EXPO - .QED TEE GRID, COLOR: WHIT - - -- - _ - -- - -. - I , T- T - -44 T3 , 1 . I ACT-2 GWB P -I all' -2 1/2' a8' -0° KEMLITE CO. KEMLITE CO. MARLITE MARLITE "KEMLITE GLASBO 4f PLUS WITH . LENGTH, C GLASS: 3 (ASTM E84), 0.090 N. THICK USDA WITH ALLEPTT:D. SIZE: Oft. WIDEXMAX. LENGT COLOR 085 MITE, EMBOSSED lEXISRE -- 2 2 1/2 PAIR BITE HINGES STANLEY MAB I /0 U526D Q BATTERY PO WERE D EXIT ALARM LOCK L -23RD EXIT CONTROL LOCK WITH EER EGL-2305 DET:X ELL-418K SIDE FULL AND WARNING AIR SIGN, (2) DETER ECL445K RIM CYLINDERS - -- 103 WOMEN'S RESTROOM 6118 NOD FIBERGLASS REINFORCED PLASTIC (PANEL TRIM) - SC ACK ORES SERVILE WALL PR PANEL ) (B FRP BORDER (BACK SERVICE WALL) KEMLITE FRP ONE -PIECE MOLDING "CONSISTING OF DIVISION BAR", ACP (AT TOP, BOTTOM, AND END PANEL), INSIDE CORNER AND OJT5IDE CORNER SYMMETRIX 5 -1000 -644 WHITE - 104 MEN'S RESTROOM T -3, T ri GAB P -I a8' -0° THRESHOLD - ALUMINUM MILL FINISH, HANDICAP ACCESSIBLE, TO FINISH FLUSH WITH INTERIOR TILE FLOORING AND CORRIDOR FLOOR. PROFILE TO MATCH DENNIS 154A. 1)5260 ALUM BORDERS x8105 SLACK 105 SERVING GAB T-2, T - T -4 T-5 AGT -2 rll' -2 I/2' 6118 SOFFIT ®e9 -'10 In' TO BE P -I ALIGN W/ EXISTING P -I P -2 P _5 - - -__- PAINT (GM) PAINT (EXISTING SURFACES) PAINT (BALK WALL SERVING -- - BENJAMIN MOORE ONE COAT OF GOORGRALi LATEX VINYL PRIMER -GLASS SEALER 55 ENAME L F2' ANC 270 °, COLOR: R: x916 COAT OF 'MOORCRAFi PROFESSIONAL COATING, LATE 5MI4LA ENAMEL x WEATHERSTRIPPING SET BRUSH PILE INSERT OF NYLON WOVEN PILE AND ALUMINUM STRIP BACKING, COMPLYING WITH AAMA 1012. - - - -- BENJAMIN MOORE BENJAMIN MOORS ONE GOAT OF "MOORGRAFT PROFESSIONAL COATING, LATEX SEMI -6LAS5 ENAMEL #210" OVER SUITABLE SPOT PRIMER, COLOR. 0916 106 PREPARATION GM EP - I EP -2 EP -2 EP -2 FRP -I FRP -2 FRP -I FRP -2 AGT -I HO' -0° ONE COAT OF 'MOORCRAFT PROFESSIONAL COATING, LATEX SEMI -GLASS ENAMEL 0276" OVER SUITABLE SPOT PRIMER, COLOR 01102 SE HOLD OPEN DEEN "4041H' 101 108 5AKE AREA OFFICE 6113 GWB EP -I EP -I SSP P -I ---- P -1 P -1 P -I ACT -I AGT -1 rl0' -0 " r+10,0. K ATE (PUSH SIDE) "05400 SORES' 16 "H x 5261 55260 P-4 P -5 _._ P -b AREA) PAINT (EXISTING CEILUNN PO FRAMES) METAL DOOR FRAMES) NOT USED BENJAMIN MOORE ONE GOAT OF °MOORCRAFT PROFESSIONAL COATING, LATEX SEMI -GLASS ENAMEL 0216" OVER SUITABLE Ib 55260 Q 3 3 6 4 I/2 PAIR HINGES STANLEY 4 1 5" x " "FEB ITq" BEN -IAMIN MOORE ISH WITH ONE GOAT "IROLA� SEMI-SLAW ENAMEL INHIBITIVE READY MIX BLACK SPO FINISH COATS OF OA OF Two HANDLE gWCTION OCK WITH ET OFFICE -LL SARGENT "10 605-LL" U526D UN':. 109 STORAGE AREA 6110 EP -I EP - 2 FRP - I FRP -2 FRP - I FRP -2 FRP -I FRP -2 ACT-I SURFACE CLOSER VV HOLD OPEN LEN "4040H° a10' -0' FLOOR STOP IVES "436° 28 P -1 P -6 P-9 P -IC P -II P -12 NOT USED PAINT (INTERIOR STEEL RAILS) URETHANE (INTERIOR WOOD DOORS D TRIM AN BENJAMIN MOORE BENJAMIN MOORE KICKPLATE (PUSH 510E) IVES VE400 SERIES' 10.H x 34 "W 05265 SPOT PRIME PITH ONE COAT OF "IRONCLAD RETARDO RUST INHIBITIVE PAINT RIOT" AND APPLY 110 151514 COATS OF "IMPERVEX ENAMEL MI33" COLOR READY MIX BLACK ONE COAT OF "BENVIOOD PASTE FILLER N 238 ", PENETRATING STAIN 0 241, AND THREE COATS OF "MOORES INTERIOR WOOD FINISHES LATEX URETHANE ACRYLIC FINISH CLEAR LOW LUSRE 8416 COLOR: TO MATCH, MARLITE: WOODGRAIN COLLECTION PLANK #318 WINDSOR ANIGRE 4 5 4 b 11/2 PAIR BJTT HINGES STANLEY 4'6" x 4 1 5" 'FED 119" U526D 0 G / ROOM C I N I SH SCHEDULE REMARKS LEVER HANDLE PRIVACY FUNCTION LOCK SET SARGENT "10 1)65,1.1" 1/5260 526D QI FOR INTERIOR WALL ELEVATIONS REFER TO SHEET A4.0 FOR LOCATION OF ALL MATERIALS AND FINISHES C) FOR TOILET ROOM ELEVATIONS REFER TO DETAIL 3 ON SHEET A6.1 03 REFER TO DETAIL 1 ON SHEET AGO FOR STAINLESS STEEL DRIP CAP OVER COVED EPDXY BASE AND PANEL EDGE DETAIL SURFACE CLOSER W/ HOLD OPEN LEN "4041H" ALUM_ NOT USED NOT USED NOT USED FLOOR STOP IVES " 28 KICKPLATE (PUSH SIDE) IVES " SERIES" 16N x 32 "W 05265 ID SEE SHEET AH.I FOR INTERIOR FINISH DIAGRAM. P -13 NOT USED DOOR S II E }/ k/�I l�la DOOR & HARDWARE SCHEDULE REMARKS NOTE: ALL LOCKS TO BE KEYED IDENTICALLY WITH 'PRIMES° CYLINDER SYSTEM. PL -I PLASTIC LAMINATE FORMICA WOOD LAMINATE ARTISAN FINISH, COLOR 45904 -45, WILD CHERRY GRAIN TTO ALLY MARK SIZE OF DOOR DOOR PRAMS FIRE REMARKS O ALL DOOR HARDWARE IS TO MEET WASHINGTON STATE CODE REQUIREMENTS FOR BARRIER FREE ACCESSIBILITY (RAC 51 -30). O AWI GRADE CUSTOM, PC- (PARTICLE BOARD CORE, 1-PLY), BIRCH PLAIN SLICED FACES, BIRCH LUMBER EXPOSED STILES. FRAME: KNOCK DOWN FIELD- ASSEMBLED PRESSED STEEL FRAMES MIN. 18 MA. LOUD- ROLLED STEEL FOR INTERIOR LOCATIONS. PAINT PER MATERIAL AND COLOR SCHEDULE. ABOVE DOUR N DOOR REMAIN G DURING O PROVIDE SIGN BUSINESS HOURS." LETTERS SHALL HALL NOT OT BE BE LEND THAN ONE INCH HIGH. PROVIDE IDENTIFYING SIGNS ADJACENT TO DOOR IN ACCORDANCE WITH WASHINGTON I IDENTIFYING I STATE REQUIREMENTS FOR BARRIER FREE DOO N A WAS 51-30 WIDTH REIG TH U MATERIAL MATERIAL MEAD JAMB SILL LABEL PL -2 PLASTID LAMINATE PIONITE P -LAM, COLOR 0, TESTA" I 6'-0° TL HT E%ISTH MATCH EXISTING EXISTN6 I 20 MID 00 0 R -3 PLASTIC LAMINATE FORMICA PLASTIC LAMINATE, 4515 -58, °GRAPHITE GRAFIX', MATTE FINISH q° MR. (MATCH EXISTING) HM. 2 5' -0" 1' -0' 111 VD H.M. A B QO PL -4 PLASTIC LAMINATE PIONITE P -LAM, SUEDE FINISH, COLOR: 511826 "ANGEL WHITE" 5' -0' 1 -0 - . 1 64 " RD HM. - A - - 0 m Oj Q WM NOT GED - - -- _ ___ ___- 5 3 -0" I' -O' YE HM. A B 4 4 Oj O® QI 02 ® 6 -O 3' " 1'-0 1 15° WD HM. A B 55P STAINLESS STEEL PANELS (BAKE AREA) METAL: AS/TYPE 304 NON MAGNETIC I8 GA. STAINLESS STEEL SHEETS WITH FACTORY APPLIED 5 FINISH - - T -1 NOT USED 1 4 7/8'� T GLAZED TILE (FLOOR TILE) SUMMITVILLE 8' 0 SMOOTH FINISH BORDER IMPERVA" SIZE °IMPERVA' SIZE 2 SQUARE, COLOR NI O S LHp� SMOOTH FINISH x ' SMOOTH FINISH t5" YP. T „;NI TILE) SUMMITVILLE T- GLAZED TILE (FLOOR TILE) _ - `X A H— HOLLOW JAM ANCHORS- T-5 GLAZED TILE (BLASE) SIIIMMINILLE SI�NILLE OPGG 89, 6° X 8" COVE BASE. COLOR TINS SILHOUETTE" MATTE GLAZE BASE METAL FRAME PROVIDE 3 PER 51015 OE (TYPICAL) R A SEND B JAMB T-0 NOT USED T -7 NOT USED T -8 T-9 5 -10 NOT USED -- DOOR /FRAME TYPES NOT USED SCALE: I = 1' -0' GROUT (FLOOR TILE) CUSTOM BUILDING PRODUCTS 0 43 "SLATE" FINISH SPEGIEIGATIONS NOT USED WALL COVERING THYBONY CUSTOM 0RUE66ER'S LOGO - SOFFIT BELTSIGN BACKGROUND (150Z. FABRIC BACKUP WALL WALL COVERING HAND SCREENED TO BE TRIMMED ON SITE DIMENSIONS = IT DEEP. FLOORING: I. CERAMIC FLOOR TILE: SUMMITVILLE'IMPBRVA 5" OCTAGONS WITH 2X2 INEILL TILE. SMOOTH FINISH. USE 8X8 SQUARE TILE AS BORDER AGAINST WALL BASE AS 5N04.1 ON PLAN. CUT BORDER TILE AS REQUIRED TO ALLOW OCTAGON PATTER TO FINISH ON FULL OR HALF TILE JOINT. OCTAGONS: 0 G 45 "SIERRA' SPILL TILE: N 168 "SILHOUETTE BORDER TILE: F165 SILHOUETTE" GROUT: CUSTOM BJILDIHG PRODUCTS #43 - "SLATE' TILE TO BE INSTALLED WITH MODIFIED LATEX MORTAR PER MANUFACTURERS: SPECIFICATIONS. TILE TO BE CLEANED AND FINISHED PER MANUFACTURERS SPECIFICATIONS. PROVIDE ALL NECESSARY TRANSITION TRIM AT 05000 AND JOINTS WITH OTTER FLOOR MATERIALS. 2. EPDXY FLOORING: STONHARD '5TONSHIELD 451' B253M01 'ASH' CUSTOM TEXTURE FOR BREWERS. FLOORING TO BE INSTALLED BY A °STONHARD' APPROVED AND LICENSED INSTALLER PROVIDE ALL NECESSARY TRANSITION TRIM AT EDGES AND JOINTS WIT4 OTHER FLOOR MATERIALS. INSTALL HIGH - TEMPERATURE FORMULA UNDER BAGEL OVEN. 3. RECESSED WALK -OFF MAT TO BE BY 'TREADLINE. WALLS: I. WOOD WAINSCOT, MARLITE °WOODGRAIN COLLECTION PLANK" 518 'WINDSOR ANIGRE." INSTALL FROM TOP OF WALL SASE TO BOTTOM OF 3/4' X 3' CHERRY GAP T21M. SEE DETAIL ON SHEET A65. FASTEN TO 618 SUBSTRATE PER MANUFACTURERS SPECIFICATIONS. CHERRY LAP TRIM TO BE STARED TO MATCH MARLITE PLANK AND FINI° ED WITH THREE (3) COATS CLEAR POLYURETHANE. PROVIDE ALL MARLITE CORNER AND TWM ACCESSORIES AS NECESSARY FOR A COMPLETE INSTALLATION 2. FRP PANEL WAINSCOT: MARLITE SYNNEIRIX' 5TIRO 644 - WHITE PANELS WITH SCORED PATTERN. ACCENT CAP TO BE MARLITE B-I05 BLACK FRP BORDER 0/4' ACH TO OERRYTAP TRIM, STAINED TO MATCH TRIM N 1 1TEM C N0. FINISH WITH SEE DETAIL ON SHEET A62. 3. PLASTIC LAMINATE WAINSCOT: FORMICA 515 -58, 'GRAPHITE 6RAFIX ", MATTE FINISH. WAINSCOT TO .54' ABOVE FINISH FLOOR ON NO VET WALLS IN EACH TOILET ROOM. ATTACH TO GWB SUBSTATE PER MAWFAGT)RERS SPECIFICATIONS. PROVIDE ALL NECESSARY TRIM AND ACCESSORIES AS NECESSARY FOR A COMPLETE INSTALLATION. q, PAINTED GYPSUM BOARD: BENJAMIN MOORE LATEX SEMI- ENAMEL BENJAMIN MI -GLOSS E PAI (N PRIMER COAT R (E) MOORE, MINIMUM. PAINT ALL NEW AND ALL EXISTING WALL RFACES. SURFACES. 5. FRP P0)5 5 KEMLITE "FIRE -X GLA5500ARD' FRP PANELS (CLASS "A" WHITE. FRP PANELS TO BE ADHERED AVM 0.090 IN THICK, 0 85 W DIRECT -Y TO G18, NO FASTENERS TO BE USED. FRP TO BE FULL SHEETS FROM TOP OF COVE BASE TO CEILING WITH NO HORIZONTAL SEAMS. PROVIDE MANUFACTURERS VERTICAL SEAM MOULDINGS AND TOP AND BOTTOM CAPS AT PANEL JOINTS. SEAL PER MANUFACTURERS SPECIFICATIONS_ PROVIDE FULL CAULKING AT PANEL PERIMETER AGAINST ADJACENT SURFACES 6. STAINLESS STEEL WALL PANELS: 18 GA. 4151 304 GRADE, #3 FINISH. PANELS TO BE FULL HEIGHT WITH NO HORIZONTAL JOINTS. APPLY OVER 5/5" F.T. PLYWOOD WITH ROUND HEAP 55 SCREWS. COVER VERTICAL JOINTS WITH 55 BATTENS, FULLY SEALED TO ADJACENT PANELS. ALL JOINTS WITH ADJACENT MATERIALS TO BE FULLY -8,,0,,1101-. SEALED. PANELS TO BE INSTALLED FREE OF BUCKLES, WAVES, AND ITV 01 SURFACE IMPERFECTIONS. PROVIDE SS DRIP EDGE UNDER BOTTOM P P P M �1 F EDGE OF PANEL OVER EPDXY COVE BASE BELOW. PROVIDE FULL (EXI WITH EQUIPMENT STALA ALL 55 ACCESSORY 45 ENDS PIECES AND K \ \Q jF JOINT CLOSURES TO PROVIDE A COMPLETE INSTALLATION. �IVIS'� CEILING: ( }I :ILJ 1. SUSPENDED ACOUSTICAL CEILING TILE ARMSTRONG 2'X4' TILE WITH 1 SCORING, SECOND LOOK I #2165, WHITE, WITH'PREWDE' 15110" EXPOSED TED GRID, WHITE. 2. DROPPED GW CUSTOM SOFFIT: STOM ITZ. FABRIC BACKED, WALL COVERING INSTALLED FABRIC AND INSTALLED BY 6. C. ORE 0916, SATIN FINISH, N COAT PRIMER S. P N CE TED GM LIN55: BENJAMIN MO MINIMUM. FINISH COATS, FITS, TS, MJM. P EXISTING GM ILING S. CE 4. (2 (2 FI FACED GYPSUM 5 ST G INC , ILING S1 /2', 5270 "FIRECODE' SQUARE-EDGE EDGE PSUM M B OARD: N PAINT CEILING PANELS TO R 2141- WHIT: VINYL FACING, H USDA APPROVED. INSTALL PANELS IN DONN DIVISION (USG INTERIORS) "LXA ENVIRONMENTAL GRID, WHITE' 5. REFER TO DETAIL 8 ON SHEET A8.0 FOR DETAIL OF FASCIA AT OVEN AND AT COOLER clTV of ruI(WILA OCT S 2199, WOOD TRIM CHERRY FIRST GRADE (FINEST GRADE OF HARD CHERRY PRODUCED). PLAIN SAWN. WP -1 MARLITE MARLITE "W205 GRAIN COLLECTION PLANK COLOR: 0318 WINDSOR ANIGRE EP -I EPDXY FLOORING STONNARD STONESHIOLD HRI, 0 253MH - " ASH' CUSTOM TEXTURE FOR BRUE66ERS EP -2 COVED EPDXY BASE STONEHARD STONESHIELD f1Rl, 0253MH - "ASH' CUSTOM 17E%1T/RE FOR BRUEG6ER5 V -1 VCT FLOORING ARMSTRONG STANDARD FXCELON VLT 051904 "STERLING" R -I RUBBER EASE ROSINS 4" BASE 050 " GRAY" VINYL COLOR: 58501 "BLACK" 54 TREAD COLOR: 325 SLACK" PROVIDE TPAZZO EDGE STRIP TO PROTECT CERAMIC TILE AROUND RECESS. REFER TO PLAN FOR SIZES AND LOCATIONS OF MATS. WALL BASE: I. CERAMIC TILE BASE: SUMMITVILLE 0 P3601, 6' X 8" LOVE BASE. COLOR: F165: SILHOUETTE" MATTE GLAZE. 2. EPDXY COVE BASE: STONHARD'STONSHIELD HRI° 0253MH 'ASH" CONTINUOUS WITH EPDXY FLOOR. DRAWN BY: I SHF.F'.T BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON 0 o ICU GGErE BAGEL, ® ff R �BRi AARz® REVISIONS T���'�p TIIF�IITTIFpT��ry1 `y 1EpINIET��FNIT ¥ P. §y� 1 , 0 Evergreen One, 10940 NE 33rd Place, Suite 202, Bellevee, WA 98004 (206 827 -2100 PROJECT NO.: 96251 A9.0 OF ? D2(v3 BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON OINTERIOR FINISH DIAGRAM SGALE: I /4" = I' -0" B' % B" BLACK TILE BORDER WD. WAINSCOT 4 CHAIR RAIL ory'S ' PERMIT CENTER REVISIONS MEMO ] l [ ll i � O ��]yyC((/ ¶� '1 1 / , y� APO INC., JL-' eLJ. Evergreen One, 10940 NE 33rd Place, Suite 202, Bellevue, WA 90004 (208 827 -2100 ^,'.'.I$708ED DRAWN BY KAL DRAWING NAME: 9623130 DATE: B/19/96 PROJECT NO.: 96221 SHEET A9.1 OF S9b--0;493 BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON REVISIONS SUSPENDED ACOUSTICAL CEILING PER PLAN 5/0 6 NB. EACH SIDE 3 5/0 20 GA. MIL STIES H IN O.G. FINISH PER SCHEDULE - FINISH PER SCHEDULE (2) COST BEADS OF SEALANT BELOW RUNNER (TYP). SUSPENDED -- - ACOUSTICAL TILE CEILING (NO CEILING BAKING OVEN) TYPICAL PARTITION WALL ONE LAYER OF 75' GAB. TYPE X ON 3 `!e" MTL. 20 GA. STUDS N I6" O.G. 1111 II 11111 4 1/N O WALL AT OVEN DIAGONAL BRACING TO EXISTING STRUCTURE ABOVE W/ 14 TL STUDS 4 4' -0' O.G. ALTERNATING DIRECTIONS. TYPICAL AT ALL NEW PARTITION WALL. —ONE LAYER OF F5" APA RATED CDX PLYWOOD AT BAKE AREA (015 THERMAL BATT INSULATION AT OVEN WALL. PULL FACE AT OVEN SIDE) OVEN 2 -CONT. BEADS OF SEALANT BELOW RUNNER FRP 5/8" PLYWOOD BLOCKING. REFER TO PLAN FOR LOCATIONS. BRUEGGERS SUSPENDED ACOUSTICAL TILE CEILING (NO CEILING BAKING OVEN) 5/0 A NB. EACH SIDE 6" 20 GA. MIL 5T/D5 N Id' O.G. ONE LAYER OF Sp APA RATED CDX PLYWOOD AT BAKE AREA (5 1 15' THERMAL BATT INSULATION AT OVEN WALL. FULL FACE AT OVEN SIDE) STAINLESS STEEL PANEL 2 -CONT, BEADS OF SEALANT BELOW RUNNER O TENANT DEMISING WALL O WALL BAKE AREA F EIHEIT ' 110 ADCHITECTs4, INC, Dodo Evergreen One, 10940 NE 33rd Place, Suite 202, Bellevue, WA 90004 (200 0 7 -2100 EXISTING TENANT w o za 01 F 0. p CI B OF E iU D ., OCT 0 2 1996 PERMIT SEM. DRAWN BY SHEET KAL DRAWING NAME 9623 '192 DATE S/19/96 OF PROJECT NO 96231 GENERAL REQUIREMENTS GENERAL CONDITIONS PROVISIONS OF THC GENERAL CONDITIONS APPLY TO THE 5009. COVERED UNDER THI0 SECTION, REFER TO THE ARCHITECTURAL DRAW1005 FOR THESE PR001510N5. SCOPE OF WORK ALL ELECTRICAL, MECHANICAL, PLUMBING. NATURAL GAS AND FIRE SPRINKLER / FIRE PROTECTION SYSTEMS WORK SHALL BE BITTER DESIGNED AND UNDER SEPARATE PERMIT, THE DRAWIN55 AND SPECIFICATION INFORMATION PROVIDED HEREIN ARE INTENDED A5 P WIDE TO A5' 5T THE CONTRACTOR IN THE DE5165 OF THESE SYSTEMS. THE WORK COVERED BY THESE SPECIFICATIONS SHALL INCLUDE THE FURNISHING OF ALL MATERIALS, LABOR, EQUIPMENT, TRANSPORTATION, TOOLS, UTILITIES AND INCIDENTALS NECESSARY FOR THE COMPLETE INSTALLATION OF ALL MECHANICAL, PLUMBING, SPRINKLER AND ELECTRICAL SYSTEMS A5 GALLED FOR ON THE CONTRACT DOCUMENTS AND SPECIFIED HEREIN. EACH CONTRACTOR SHALL PAY ALL PERMIT FEES, PLAN REVIEW FEES, LICENSE FEES. INSPECTIONS AND TAXES APPLICABLE TO THE DIVISION AND SHALL INCLUDE ALL COSTS IN THE BA55 BID AS PART OF THIS CONTRACT. QUALITY ASSURANCE THE WORK UNDER THIS 5E5TION OF THE 505015 OATIONS SHALL BE INSTALLED IN STRICT A000RDANOE WITH ALL LAWS, CODES, O 01065CE5 AND REQUIREMENTS OF THE LOCAL VILLAGE /CITY, COMM STATE AND ANY OTHER AUTHORITIES HAVING LAWFUL JURISDICTION INCLUDI LOCAL UTILITY COMPANIES. ALL EQUIPMENT, 0501600, FixDRE5 AND MATERIALS SHALL BE NEW OF FIRST QUALITY AND CONFORM TO THE APPLICABLE STANDARDS HEREI IN ANY INSTANCE WHERE THESE SPECIFICATIONS GALL FOR MATERIALS FOR CONSTRUCTION OF A BETTER QUALITY OR LARGER SIZE THAN REQUIRED BY THE REFERENCED STANDARDS, THE PROVISIONS OF THESE SPECIFICATIONS SHALL TAKE PRECEDENCE. THE NEW WORK SHALL BE COORDINATED WITH, MEET OR EXCEED THE BASE BUILDING CONSTRUCTION STANDARDS FOR THIS PROJECT. ALL MATERIALS SHALL CONFORM To THE REQUIREMENTS OF THE GOVERNING CODE, DRAWINGS WHERE DIMENSIONS ARE INDICATED ON PLANS FELD VERIFICATION OF DIMENSIONS IS DIRECTED AS ACTUAL LOCATIONS, DISTANCES AND LEVELS WILL BE GOVERNED BY FIELD CONDIT10 5. THE DRAWIN65 MAY 501 SHOW COMPLETE OR ACCURATE DETAILS OF THE EXISTING 1311LDING IN EVERY RESPECT. EXACT LOCATIONS AND RELATIONSHIP' ARE TO BE DETERMNE0 IN FELT AND SHALL 50 TO THE SATISFACTION OF THE ARCHITECT. THIS CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL FIELD MEASUREMENTS. THE DRAWINGS INDICATE DIAGRAMMATICALLY THE GENERAL INTENT, CHARACTER, REQUIREMENTS QUANTITY AND APPROXIMATE LOCATION OF THE WORK SHOWN AND 1NDICATED. WORK INDICATED BUT HAVING MINOR DETAILS OBVIOUSLY OMITTED FROM THE DRAWINGS AND SPECIFICATION SHALL HAVE THESE DETAILS PROVIDED AT NO ADDITIONAL COST TO THE OWNER. IN CASE OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER DOCUMENT, THE ARCHITECT SHALL 25TERMINE THE INTENT. IN SIGH CASE, IN GENERAL, THE STRINGENT REQUIREMENT REQUIRING THE GREATER QUANTITY OR QUALITY AND /OR RESULTIN5 THE HIGHER COST SHALL GOVERN WITHOUT FURTHER COST TO THE OWNER. IT IS EACH CONTRACTORS RESPONSIBILITY TO REVIEW THE ENTIRE SET CF CONTRACT DOCUMENTS: INCLUDING BUT NOT NECESSARILY LIMITED TO ALL THE ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL AND ALL MISCELLANEOUS DRAWINGS AND DOCUMENTS EACH CONTRACTOR SHALL ACKNOWLEDGE AND INCLUDE IN THE SCOPE OF WORK (CONTRACT) ALL CONDITIONS PERTINENT TO THE COMPLETION OF THEIR WORK. 540ULD THE CONTRACTOR FIND ANY DI50REPANOIES BETWEEN EXISTING CONDITIONS AND NEW WORK, OR BETWEEN THEIR WORK AND THE WORK OF OTHER TRADE, OR OMISSIONS FROM THE DRAWINGS SPECIFICATIONS OR OTHER DOCUMENTS, OR BE IN DOUBT A5 TO THEIR MEANING, NOTIFY THE ARCHITECT AT ONCE, IN WRITING AND OBTAIN CLARIFICATION PRIOR TO SUBMITTING ANY BID. LACK OF SUCH NOTIFICATION SHALL BE INTERPRETED TO INDICATE NO DISCREPANCIES OR CONFLICTS EXIST. ADDITIONAL COMPENSATION WILL NOT BE GRANTED AFTER AWARD OF CONTRACT FOR ANY WORK REQUIRED TO COMPLY WITH THESE REQUIREMENTS. EACH CONTRACTOR SHALL FULLY COORDINATE THEIR WORK WITH THE INSTALLATION OF WORK BY OTHER TRADES AND MAKE NECESSARY FIELD ADJUSTMENTS AS REQUIRED TO ACCOMMODATE THE INSTALLATION, ALL ACCEPTED SHOP DRAWINGS FOR MATERIALS AND EQUIPMENT FURNISHED ON THE PROJECT SHALL BE REVIEWED BY EACH TRADE CONTRACTOR FOR ANY NECESSARY ALTERATIONS FORA COMPLETE AND SUCCESSFUL OPERATING INSTALLATION, SUBMITTALS PROMPTLY AFTER AWARD OF CONTRACT AND PRIOR TO ORDERING ALL NEW ITEMS SPECIFIED (EQUIPMENT, DEVICE5, 01005E AND MATERIALS) EACH CONTRACTOR SHALL SUBMIT FOUR (4) SETS OF SHOP DRAWINGS FOR ARCHITECT REVIEW. SHOP DRAWINGS SHALL CONSIST OF MANUFACTURER'S OATALO6 OUTS AND /OR DESCRIPTIVE DATA SHEETS WITH 60N1ROL WIRING DIAGRAMS FOR ALL SPECIFIED EQUIPMENT EACH CONTRACTORS BID SHALL BE BA5ET ON THE EQUIPMENT SPECIFIED HEREIN. IF THE CONTRACTOR PROPOSES ALTERNATE SELECTIONS, THEY MUST BE LISTED ON THE BID PROP05AL 65 A DEDUCTIVE ALTERNATE. CATALOG CUTS FOR ALL PROPOSED ALTERNATE SELECTIONS SHALL BE `0IBMITTED WITH THE BID PROPOSAL. ALTERNATE EQUIPMENT SELECTIONS WILL NOT BE PERMITTED AFTER AWARD OF CONTRACT. WHERE EQUIPMENT /DEVICES ARE INDICATED OF THE DRAWING5, THE DIMENSIONS HAVE BEEN TAKEN FROM TYPICAL EQUIPMENT OF THE CLASS INDICATED. THE CONTRACTOR SHALL CAREFULLY CHECK THE DRAWINGS AND DETERMINE THAT THE PROPOSED EQUIPMENT TO BE FURNISHED WILL FIT INTO THE SPACE PROVIDED. EACH CONTRACTOR SHALL SUBMIT FINAL PROPOSED SHOP DRAWINGS AT 1/4" SCALE MINIMUM, SHOWING THE EQUIPMENT, FIXTURES DEVICES PIPING, DUCTWORK (DOUBLE LINE), COMMITS AGCE550RIES AND ETC. TO THE ARCHITECT FOR APPROVAL, PRIOR TO THE BEGINNING OF CONSTRUCTION. PROJECT COORDINATION EACH CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION AND PROPER RELATION OF THEIR WORK TO THE BUILDING STRUCTURE AND WITH THE WORK OF ALL OTHER TRADES. MAKE NECESSARY FIELD ADJUSTMENTS TO ACCOMMODATE THE INSTALLATION. EACH CONTRACTOR SHALL PROVIDE A COMPETENT FIELD SUPERINTENDENT WITH KNOWLEDGE AND PREVIOUS SUCCESSFUL EXPERIENCE ON PROJECTS OF COMPARABLE SIZE AND 00MPLEXITY. WHERE THERE 15 NO MENTION OF THE RESPONSIBLE PARTY FORA SPECIFIC ITEM TO BE FURNISHED AND /OR INSTALLED ON THE DRAWINGS THE DRAWINGS TRADE CONTRACTOR SHALL BE COMPLETELY RESPONSIBLE FOR ALL RELATED PURCHASES AND LABOR FOR A COMPLETE OPERATING SYSTEM FOR THIS ITEM. EACH CONTRACTOR SHALL FURNISH ROOF EQUIPMENT AND SUPPORT CURDS, AS REQUIRED FOR THEIR TRADE ITEMS TO THE ROOFING CONTRACTOR. THE ROOFING CONTRACTOR WILL INSTALL THE ROOF EQUIPMENT AND `JJPPORT CURBS AT SPECIFIC LOCATIONS A5 COORDINATED AND DIRECTED BY THE TRADE CONTRACTOR EACH CONTRACTOR SHALL VERIFY ALL EQUIPMENT MOUNTING ARRANGEMENTS HEIGHTS AND LOCATIONS PRIOR TO ROUGH -114. ANY MENTION OF A SPECIFIC MOUNTING ARRANGEMENT, HEIGHT OR LOCATION SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO VERIFY THE SPECIFIC REQUIREMENT WITH THE EQUIPMENT FURNISHED OR THE COORDINATION WITH OTHER EQUIPMENT OR TRAD05 WORKING IN THE SAME AREA EACH CONTRACTOR TO IMMEDIATELY COORDINATE WITH LOCAL UTILITY COMPANIES UPON AWARD OF CONTRACT. EXPEDITE ALL AGREEMENTS WITH UTILITY COMPANIES TO PREVENT ANY DELAY OF ENERGIZATION OF NEW SERVIOE(5). INCLUDE ALL COSTS IN BASE BID. EACH CONTRACTOR 15 RESPONSIBLE FOR SCHEDULING DELIVERY, RECEIVING, UNLOADING, STORING, UNCRATIN5 SETTING IN PLACE. AND PROTECTING FROM DAMAGE, VANDALISM, THEFT OR WEATHER DURING CONSTRUCTION FOR ALL NEW EQUIPMENT FURNISHED BY THE CONTRACTOR, OR FURNISHED BY OTHER PARTIES TO THE CONTRACTOR FOR INSTALLATION BY THE CONTRACTOR. COORDINATE ALL DELIVERIES TO MEET THE PROJECT COMPLETION DATES A5 ESTABLISHED BY THE OWNER. THE KITCHEN EQUIPMENT INFORMATION 15 BASET UPON INFORMATION PROVIDED BY THE OWNER. IN SOME INSTANCES EQUIPMENT MAY VARY OR THE OWNER OR SUPPLIER MAY SUBSTITUTE ITEMS THAT COULD VARY FROM WHAT 15 CALLED FOR. FOR THIS REASON, THE CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND EQUIPMENT CHARACTERISTICS WITH THE OWNER PRIOR TO CONSTRUCTION. f ib -D.2 3 BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON SAFETY EL CTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL TEMPORARY WIRING- FOR HAND TOOL` AND 00N5TRUCTION LIGHTING PER LATEST OSHA STANDARDS AND INCLUDE ALL 00:-75 IN THE BASE T.D. EACH CONTRACTOR SHALL ESTABLISH SAFE WORKING PRO6EDURES FOR THE PROTECTION OF THE WORKMEN IN ALL PHASES of WORK, COMPLYING WITH THE APPLICABLE FROVI510N5 OF THE CITY, STATE AND FEDERAL SAFETY LAN' (0564) AND 05 RECOMMENDED IN THE "MANUAL OF ACCIDENT PREVENTION IN CONSTRUCTION" AS I55IED 55 THE ASSOCIATION OF GENERAL CONTRACTORS OF AMERICA, INC., 20TH AND E 5TREETS NW. WASHINGTON, TC. THE ARCHITECT MAY MAKE PERIODIC VISITS TO THE JOB 517E TO OBSERVE THE PROGRESS OF THE WORK AND TO OBSERVE WHETHER OR NOT IT I5 BEING PERFORMED IN ACCORDANCE WITH THE CONTRACT DRAWINGS AND 5PECIFICATIONS. THIS 00E5 NOT IN ANY WAY MEAN THAT THE ARCHITECT 5 A GUARANTOR OF THC CONTRACTOR5 WORK, OR RESPONSIBLE FOR SAFETY IN, ON OR ABOUT THE JOB 51 IN CONTROL OF THE SAFETY OR ADEQUACY OF ANY SHIPMENT, BUILDING, 50AFFOLDIN6, FORMS OR OTHER WORK AIDS, OR FOR SUPERINTENDING DIRECTING 00 HAVING CHARGE AT TIE ERECTION AND /OR CONSTRUCTION OF THE EXISTING CONDITIONS EACH CONTRACTOR SHALL VISIT AND INSPECT THE EXISTING BUILDING AND SHALL THOROUGHLY FAMILIARIZE THEMSELVES WITH ACTUAL JO5 0000111055 PRIOR TO SUBMITTING A PROPOSAL. FAILURE TO DO 50 SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING THE WORK REQUIRED UNDER THIS CONTRACT. NO EXTRA CHARGES WILL BE ACCEPTED FOR WORK WHICH MUST BE PERFORMED DUE TO THE 00NTRACr0R5 FAILURE TO VERIFY THE EXI5TIN6 CONDITIONS. PERFORM DEMOLITION WORK THAT MAY BE REQUIRED OR NECE55ARY FOR A FULL AND COMPLETE EXECUTION OF 5H0 WORK, WHETHER OR NOT SHOWN OR SPECIFIED. EXACT: EXTENT OF DEMOLITION MAY NOT BE FULLY INDICATED BY THE DRAW1909 . DETERMINE THE NATURE AND EXTENT OF DEMOLITION THAT WILL BE NECESSARY BY COMPARING THE 6ONTRAC- DOCUMENT5 WITH EXISTING 0014015 000. EACH CONTRACTOR SHALL DISCONNECT AND REMOVE EXISTING MATERIALS, EQUIPMENT, AND ALL OTHER ITEM5 WHICH ARE RENDERED OBSOLETE BY THESE ALTERATIONS AND ADDITIONS. THESE ARE THE PROPERTY OF THE BUILDING OWNER AND SHALL BE RETURNED TO THE BUILDING OWNER 00 REMOVED FROM THE 517E AND 015505ED OF PROPERLY BY THE CONTRACTOR AT THE DISCRETION OF THE BUILDING OWNER. INCLUDE ALL 00575 FOR DISPOSAL OF EQUIPMENT IN BASE BID CONFER WITH THE MANUFACTURERS OF EXISTING EQUIPMENT WHICH 15 TO BE MODIFIED OR EXTEND AND INCLUDE 00510 OF ALL REQUIRED MODIFICATIONS IN BASE BID. WHILE THE SIZE AND LOCATION OF NEW WORK AND EQUIPMENT IN THE EXISTING BUILDING HAS BEEN INDICATED ON THE DRAWINGS AS ACCURATELY AS POSSIBLE, EACH CONTRACTOR SHALL ADJUST AND ADAPT THEIR WORK TO MEET ALL ACTUAL CONDITION5 ON THE EXI5TIN6 PREMISE. MAINTAIN THE SPACES SURROUNDING THE AREA OF WORK CLEAN AND CLEAR OF ALL CONSTRUCTION DEERS THROUGHOUT THE ENTIRE PROJECT DURATION. WHERE EXISTING EQUIPMENT /DEVICES /SYSTEMS PREVENTS THE PROPER CONSTRUCTION OF NEW WORK CALLED FOR ON 154111NGS, REMOVE, RE- ROUTE, RELOCATE OR IN OTHER WAYS ALTER THE EXISTING WORK IN ORDER TO ACCOMMODATE THE NEW WORK REQUIREMENTS. WHERE EXISTING EQUIPMENT/DEVICE5 /5Y5TEM5 MUST BE REMOVED AS A RESULT OF THE ALTERATIONS, THEY SHALL BE REMOVED COMPLETELY BACK TO THE FIRST JUNCTION POINT WHICH 15 UNAFFECTED BY THE ALTERATIONS. EXISTING EQUIPMENT/DEVI0E5 /SYSTEMS NOT BEING REUSED SHALL BE REMOVED COMPLETELY 05157105 SYSTEMS (MOTS, PIPES 00NDUITS ETC) MAY BE REUSED PROVIDED THEY ARE FREE OF DEBRIS AND IN LIKE NEW CONDITION. WHERE EXISTING SYSTEMS ARE BURIED IN CONCRETE OR OTHERWISE IN AOCES0IBLY POSITIONED THEY MAY BE ABANDONED IN PLACE PROVIDED THEY ARE CLEAR OF DEBRIS AND GAPPED AT EACH END. WHERE THE RELOCATION OF DUSTING DUCTS, PIPES CONDUITS, OR DEVICES SERVING ANY 05151195 EQUIPMENT OR FIXTURES IN THE AREA OF THE EXISTING BUILDING NOT 5E156 ALTERED OR INTERFERED WITH 15 REQUIRED, THE CONTRACTOR SHALL DISCONNECT, REROUTE AND RECONNECT ALL SUCH ITEMS, AT THE BEGINNING OF CONSTRUCTION, THE MECHANICAL CONTRACTOR SHALL SEAL THE EXISTING DUCTWORK SERVING THE AREAS OF NEW WORK TO REDUCE DUST CONTAMINATION INTO THE BUILDINGS SYSTEM. EAC1 CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN THE EXISTING BUILDING SYSTEMS IN OPERATION AT ALL TIMES TIRING THE ENTIRE CONSTRUCTION PERIOD. IF IT 15 ABSOLUTELY NECESSARY TO SHUT DOWN A PART OF OR THE ENTIRE FACILITY AT ANY TIME, THIS CONTRACTOR SHALL 6AN0LT WITH THE GENERAL CONTRACTOR AND BUILDING OWNER TO MAKE ARRANGEMENTS TO DO 50 AT THE OWNERS CONVENIENCE. EACH CONTRACTOR SHALL GIVE A MINIMUM OF 48 HOURS NOTICE BEFORE SHUTTING DOM ANY PART OF THE BUILDING, AND OBTAIN BUILDING OWAERS WRITTEN AUTHORIZATION. INOLUS E ALL PREMIUM TIME CHARGES IN BASE BID. EXCAVATION 4 BAOKFILL EACH CONTRACTOR SHALL PROVIDE ALL EXCAVATION, TRENCHING, BACKFILL AND TAMPING REQUIRED FOR THE INSTALLATION OF THEIR WORK. PROVIDE ALL NECESSARY SHEATHING AND BRACING, UNDERGROUND PIPING SHALL BE LAID ON A MINIMUM OF 4" GRANULAR BED OF CRUSHED STONE OR GRAVEL. WHERE A TRENCH HAS BEEN CUT LOWER THAN LEVEL REQUIRED, CONTRACTOR SHALL FILL TRENCH WITH CRUSHED STONE OR GRAVEL FOR BEDDING UP TO THE PROPER LEVEL. FILL SHALL BE COMPACTED TO PREVENT SETTLING. EACH CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND PROPER DISPOSAL OF ALL SURPLUS MATERIALS REMOVED DURING EXCAVATION FROM THE 51TE. SITTING d PATCHING NO HOLES OR RECESS MAY BE CUT IN WALLS FLOORS CEILING, OR ANY PART OF THE 0010n145 WITHOUT PRIOR DEG/5510N TO AND REVIEW AND APPROVAL BY THE EUILD1146 OWNER. ALL CUTTING, DRILLING, CORING, ETC. SHALL BE PERFORMED BY A COMPETENT MECHANIC SKILLED IN THIS FIELD IN A NEAT AND CRAFTSMAN LIKE MANNER AND SHALL BE DONE NBT WHERE POSSIBLE TO MINIMIZE THE SPREAD OF DUST. THE PORTIONS OUT KIST BE RESTORED TO THEIR ORIGINAL CONDITION TO THE FULL SATISFACTION OF THE ARCHITECT /OWNER. EACH CONTRACTOR SHALL INCLUDE ALL COSTS FOR ALL REQUIRED CUTTING AND PATCHING FOR THE RESPECTIVE TRADES WORK. EACH CONTRACTOR SHALL FIREPROOF ALL OPENING BETWEEN FLOORS AND INTERSPACE FIRE SEPARATION BLOCK WALLS APPROVED UL LISTED FIRE RETARDANT MATERIAL AS REQUIRED. OPENINGS IN FLOORS SHALL BE CORE DRILLED AND /OR SAW CUT AS REQUIRED FOR THE PROPER INSTALLATION OF THE WORK. NO CHOPPING ALLOWED, CLEANING ALL WORK AREAS WILL BE KEPT GLEAN BY THE CONTRACTORS WITH TH0ROU65 CLEAN UP AT THE END OF EACH DAYS WORK. UPON COMPLETION OF THE WORK, EACH CONTRACTOR SHALL REVIEW AND CHECK THE ENTIRE PORTION OF WORK, GLEAN EQUIPMENT AND DEVICES, REMOVE SURPLUS MATERIALS AND RUBBISH FROM THE OWNER'S PROPERTY, LEAVING THE WORK IN NEAT AND CLEAN ORDER AND IN COMPLETE WORKING CONDITION. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF ANY CARTON, DEBRIS, ETC., FOR EQUIPMENT FURNISHED AND INSTALLED BY THE 00NTRACTOR OR FURNISHED BY OTHER PARTIES AND INSTALLED BY THE CONTRACTOR. IDENTIFICATION EACH MAJOR COMPONENT OF EQUIPMENT SHALL HAVE THE MAW0ACTURER'S NAME, ADDRESS, AND CATALOG NUMBER ON A PLATE SECURELY ATTACHED TO 114E ITEM OF EQUIPMENT. ALL DATA ON NAMEPLATES SHALL BE LEGIBLE AT THE TIME OF FINAL INSPECTION, IDENTIFY PIPIN6, CONCEALED OR EXPOSED, WITH PLAOTIO TAPE PIPE MARKERS. TAGS MAY BE USED ON SMALL DIAMETER PIPING SUCH AS COLD WATER PIPING. IDENTIFY SERVICE AND FLOW DIRECTION, INSTALL IN CLEAR VIEW AND ALIGN WITH AXIS OF PIPING, LOCATE IDENTIFICATION NOT TO EXCEED 20 FEET (6 M4 ON STRAIGHT RUNS INCLUDING RISERS AND DROPS ADJACENT TO EACH VALVE, AT EACH 510E OF PENETRATION OF STRUCTURE OF ENCLOSURE, AND AT EACH OB9TFU6TION, IDENTIFY MECHANICAL EQUIPMENT AND DOMESTIC WATER HEATER WITH GLOSS ENAMEL PAINT USING GLEAN CUT, 2" HIGH (141NIMU4, LETTE0 AND NUMBER STENCILS. IDENTIFY ELECTRICAL EQUIPMENT WITH PERMANENT IDENTIFICATION NAMEPLATES FOR EACH ITEM OF ELECTRICAL APPARATUS AND ASSOCIATED CONTROLLED EQUIPMENT WITH THE DESIGNATION INDICATED ON THE DRAWINGS. NAMEPLATE SHALL BE WHITE WITH BLACK CORE I - 1/4" X B MINIMUM, I/4" HIGH LETTERING AND APPLIED WITH NON - CORRODING TYPE SCREWS OR RIVETS. SYSTEM OPERATION IF A SYSTEM DOES NOT APPEAR TO BE FUNCTIONING PROPERLY 7E515 SHALL BE PERFORMED TO DETERMINE IF WHETHER IT MEETS THE PERTINENT SPECIFICATION. ANY MEASUREMENT DEEMED NECESSARY BY THE ARCHITECT SHALL BE MADE. MODIFY OR ADJUST THE SYSTEM/EQUIPMENT TO MEET THE SPECIFICATIONS FOR THAT PARTICULAR ITEM OF EQUIPMENT AND THE FUNCTIONAL REQUIREMENTS OF THE COMPLETE SYST =M. GUARANTEE EACH CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FOR A PERIOD OF TWELVE MONTHS AFTER FINAL ACCEPTANCE OF THE WORK BY THE ARCHITECT AND OWNER EACH CONTRACTOR SHALL REPAIR, AT THEIR OIYN EXPENS0, ANY PART OR PARTS OF THE EQUIPMENT, DEVICES AND MATERIALS WHICH BECOMES DEFECTIVE WITHIN THE SPECIFIED PERIOD OF TIME EXCEPT WHEN DUE TO THE OWNER5 CARELE550155 IN OPERATION. PERMANENT RECORDS d OPERATING INSTRUCTIONS AT THE TIME THE SPACE/BUILTIN6 15 OFFICIALLY TAMED OVER TO THE OWNER THE CONTRACTOR SHALL FURNISH TO THE ARCHITECT /OWNER, FOUR (4) COMPLETE PORTFOLIOS 001454 0 NG CONTRACT RECORD 00540185, SHOP DRAWINGS, 00MPLETE OPERATING INSTRIJC ON5, EXPLODED EQUIPMENT DRAWINGS INDICATING PART EMBERS, MAINTENANCE MANUALS WIRING DIAGRAMS TESTING DATA ETC FOR ALL ITEMS OF 001.3PMENT AND DEVICE FURNISHED UNDER THIS CONTRACT. KEEP RECORDS OF ALL TESTS, IN TABULATED, PERMANENT, REPRODUCIBLE FORM, COMPLETELY INDEXED AND EXPLAINED, INDICATION THE SPECIFIC TEST PERFORMED, ENVIRONMENTAL CONDITIONS 5KH AS TEMPERATURE AND 154110 Y, DATE Or PERFORMANCE, RESULTS OBTAINED, CORRECTIVE ACTIONS TAKEN (15 ANY), FINAL RE5LLT5 Al. COMMENTS IF REQUIRED. EACH CONTRACTOR SHALL FURNISH CONTRACT RECORD 800400NT5 TO T!E ARCHITECT BEFORE FINAL PAYMENT WILL BE 155102. THE CONTRACT RECORD 000060NT5 SHALL DIAGRAMMATICALLY INDICATE THE INSTALLED CONDITION FOR ALL WORK AND BE IN REPRODUCIBLE DRANIN6 FORM, INSTRUCTIONS TO OWNER THE EQUIPMENT MANUFACTURER SHALL PROVIDE THE SERVICES C P A QUALIFIED FPLTORY TRAINED WORKMAN TO SUPERVISE THE TESTING, STARTING UP OF EQUIPMENT, ADJUSTING, BALANCING, ETC., REQUIRED FOR PROPER OPERATION AND USE OF EQUIPMENT AFTER THE ABOVE WORK AND SERVICES HAVE BEEN SATISFACTORILY PERFORMED, THE EQUIPMENT MANUFACTURER SHALL FURNISH THE 5ERVI0E or A QUALIFIED FACTORY TRAINED REPRESENTATIVE TO FULLY IN5TRIUCT THE OWUNER5 OPERATING PERSONNEL IN THE PROPER OPERATION, MAINTENANCE AND SERVICE OF THE EQUIPMENT INSTALLED. 41111 _EGG121R °0IBAGNL o REVISIONS Fl EIlEJ[T 4 110 " AQCI - II CT44 INC., DA. _° Evergreen 0441, 10940 NE 33rd Place, Suite 202, Bellenle, WA 98004 (200 821 -2100 DRAWN BY: KAL DRAW450 NAME: 0825TMPI DATE' 8/15/06 PROJECT NO 56217 C TUKWIL4 OCT021 PERMIT CENTER SHEET MPE1 OF SECTION 15001 - GENERAL PROVISION GENERAL PROVISIONS PAR -' GENERAL COI GENERAL REQUIREMENTS d General Provisions of contract, Including Drawings and is work of this section. g Requirements a Provisions apply 102 `LOPE OF WORK A stems. Provide coordination, dell a Systems. design, lolror, m atanals an pp Ilances d perform operations i connection with satisfactory installation of ochanlcal work ready to operate In strict accordance with these specifications and drawings. Work includes, but Is not limited to, that as delineated 'n the Fbhowlna speclNcalion sections, 15001 General Provisions 15100 Basic Materials and Methods 15300 Fire Protection Systems 5400 Plumbing systems - 15438 Natural Gas System 15800 HVAG Systems B. acilites, Provide mechanical systems to support renovation of the existing space as follo5s. I Plumbing Provide at new plumbing fixtures. b. Provide all new Inferior, domestic water piping. Provide all new waste and vents stem_ c. d. Provide new water heater y e. Provide floor drains and floor sinks. f. Provide kitchen Fixtures, piping and accessories as required b Equipment Plan, Equipment Schedule and Kitchen Rough -In Plarn. 2. Natvral Gos System: N Provide all new natural gas service to HVAL, hot weer healer and kitchen meat. b. Coordinate with local natural gas utility. 3. Heat and Ventilation: a. Evaluate existing rooftop air condbon!ng system For reuse I dining and serving areas. b. Provide rooftop heat and vent (make -up air) system for prep and baking areas. c. Provide duct and rooftop fans For kitchen hoods. d. Provide exhaust fans for toilets. 103 PROPOSAL AND SELECTION A. Proposals shall contain, but not be limited to, the Following data: I. Basic contract price for systems described herein, 2 Adjustments to contract price For alternates. 3. Itemized Ilst of equipment, materials and services to be provided 4 Schematic drawings of proposed systems. B. Contractors are Invited and encouraged to develop and submit for consideration, alternates to the basic systems and subsystems. 104 COPES AND STANDARDS Conform to followingg ode and a Irements harm jurisdictional authority over mechanical Ins}allatlon: agency regv g J y Uniform Building Code 1.111f one Mechanical Code Uniform Plumbing Lode National Electric Code Local Sewer and Welter District Requirements Local Department of Health Uniform Fire Code National Fire Protection Association (NLPA) Washington Industrial Safety and Health Act (WISHA) Washington State Non - Residential Energy Code (NREC) 105 FINAL CONSTRUCTION APPROVAL Recommended con completion of the following: upon p o Operation of Architect's final observation report Operation and maintenance manuals Op Operation Instruction period - Permit submittal As -built drawings Testing and cleaning 106 TERMS OF CONTRACT A. Pions and Coordination: Provide drawings In accord with General Contractor's schedule. Provide I/4" scale floor plans and other details as necessary For coordination and a well Integrated design. B. Submittals (To Architect). Submit for review calculations, shop drawings, brochures (catalog data), and lists In accord with General Requirements. Turn in all Division 15 submittals as a single unit. Do no fabrication or manufacture of products until receipt of Architect's approval of submittals. G. Substitutions: Manufacturers and models of equipment and material Indicated herein and on drawings are those upon which mechanical quality standards are based. Other manufacturers with products considered equal re listed without specific model designation. For substitution of any other manufacturers' equipment, see General Requirements. OT DOCUMENTATION A. Permits: paid For and obtained by contractor. B- L. D. hoer Instructions 108 ELECTRICAL A. B. 109 WARRANTY Warrant Conditions. water Warrant 10 COORDINATION A. tra Wades. Contractor B. Insure LUBRICATION icate Lubricate used service 5 GUTTING Coordinate adjacent ad scent END OF SECTION SECTION 15100 - BASIC PART I GENERAL 1.01 GENERAL Conform Requirements. 1.02 SCOPE This section the the systems 1.05 MATERIALS A . Use class B. Protect L . P catalog conspicuous PART 2 PRODUCTS 201 PIPE AND A. Cost Bell No B. Steel Fittings: Malleable Cast G. Copper Fittings: D. Capper Flt 2 02 VALVES Oper hers Gate: Globe: Check, Ball 205 PIPING A. Unions: B. Access or in C. Insulating As-built Drawings. See Division Genera Requirements. Show location of equipment and size of piping and ductwork Locate all )elves cocks dampers and anion equipment operating and Maintenance Manuals: Furnish Four (4) copies of operating and maintenance manuals. Manual shall be hard cover loose- leaf with index and tabbed Sections. Manual shall include the Following: anufacturers, suppliers, and subcontractors' names, addresses and phone numbers . Schedule and description of routine maintenance For each component to include oiling, lubrication and greasing data; and belt sizes, types and lengths. Balancing and test data Manufacturer's cuts and rating :cbles. Port numbers of all replaceable Items. Control diagrams and sequence of operating_ WHtten guarantees. As- Irullts corrected and completed. opecalloe Iretructlon Period. Conducted bt Gonteclbr during minimum (4) hour period. Deliver and post all operation and maintenance at this time Power Wiring: Soo Division 16. Control Wiring: See Section 15800. materials and workmanship In accord with the General Provide written tees which exceed one h as on domestic hot heater and similar Items. Submit with Maintenance and Operating Manual. period to extend from date of substantial completion. Or WORK C design and shop drawings to h preclude Si t t between Conflicts shall be brought to the attention of the General prior to insttallatlan. proper "rough -In" on all equipment to which connections are made. all moving ruptured seals pace W excessive manufacturer's Re p lubrlcatian a Attach service record label with Replace. r for future to all major equipment. AND PATCHING all cuttln d t to install work. Patch) h II match surfaces. g an patching g recessary n9 s a MATERIALS AND METHODS REQUIREMENTS to General Conditions, the modifications thereto, General Includes products, asxmblles and methods applicable to more than ono of specified In the following sections of Division 15. AND EQUIPMENT of omcls of a sl F t hre two more us o of ec are requlredu Use new w eq or and materinitalsf same . materials stored on site against weather, corrosion and dirt. major components of eqv Pln eat with manufacturer's name, address, ma number and capacity Indicated on a nameplate, securely affixed Ina place. • FITTINGS Iron Soil Pipes and Fittings, and Spigot. ASTM 5 -14 -Fbb: GISP1 501 Pipe, Black and Galvanized: ASTM A -120 Iran screwed: ANSI 0163 Iron screwed: ANSI BI6.4 Tubing: ASTM B -58 Wrought copper, ANSI 816.22 DW VC: ASTM legs: C ast bass, 816.23 8306 AND SPECIALTIES king Val Elbe Crane, Stockton) or Milwaukee equal to Niao model list: , T -III T -211 n -4i3 T -580 -Y SPECIALTIES f type. Sjspac. Ground joint, mal leable Grinnell, Grano, Walworth, Panels: Sam¢ type and construction as those specified in Section 08 Mllcar, Typo "K" with screwdriver operated lock. Stainless steel access panels tile walls. Union: Epee, capitol. IS nckel plated. 204 205 2.06 201 2 PART 3 301 3.02 3.03 MECHANICAL SUPPORTING DEVICES A. Pope straps Perforated galvanized sheet steel, el8 gauge, 3/4" wide with I/4" holes I /2° OG. E Pipe Hangers: Components and assemblies in accord with MSS 5P-53 and ANSI 8311 C. Duck Hangers. In accord with SMAGNA Low Pressure Duet Construction standards. IDENTIFICATION A. Equipment Nameplates. Black bakelit with white lojon, I/O " letterng with equipment schedule designation (e.g., 'EFL au , Exhaust Fan') g. Valve Tags: I -1/2" d meter brass, aluminum, a 3/32 plastic stamped to Indicate service and valve number, I/2° lettering, chain hager_ valve list to be posted under glass or plastic In approprlcw mocha room and to be Included In maintenance manual. g: Semi -ngld plasbc coil markers with written .« c. ape Ma -kind roun c de hackgd and Flow arrow i ii In award with AN51 A(31. a PAINT A. Factory Finished Equipment See individual equipment specification. B. Ductwork: Paint interior of ductwork vb ible through grilles and diffusers with Flat black paint. Prepare and paint surfaces in accord pith Section 09900. PIPE INSULATION Preformed Glass Pleer: 4 le density, 0.2450 at 15 deg -ees F mean hoop., 1050050 APT or e Jacke4 Manville Micro -Lock, qua DUCT INSULATION Glass Fiber pact Wrap: -I//2 lb_ density, 024K at 75 degrees F mean tome, foil jacket. minimum R -33 Installed. Manville 812 or equal. EXECUTION PIPE AND PIPE FITTINGS A. Underground Ferrous Piping t Fittings (Except cast Iron sal piping), Machine wrap with polyvinyl chloride (PVC) pressure sensitive tope 0020' (Scotchrvrap) to Include risers at buildings to a minimum of a above Tade. B. Pipes: Remove burrs by reaming. Use pipe cement on male Ureads only . G. Openhgs In Pipes: Keep closed during progress of work. D. Concealed Piping: Install so as not to interfere with light fixtures or other trade components. E. Close Nippleh: Not permitted on any part of work Use stadad short nipples P short pipe connections. Use of blshings not permitted. F. capper Tubing: Continuous. copper tubing inserts 0 runs of steel pipe not perrAted. Solder Joints in copper piping_ Da not lay copper Wang on rocks or gravel. G. Pipes of Dissimilar Metals: hake corrections with hsuladng (Dielectric) unions. H. Gutting Copper Pipe: Use a cutter. Smooth chap edges with emery cloth. I. Saddles on Pipe: Not permitted. 'VALVES AND SPECIALTIES A. Mons, Install at final connections to I t and on c ontrail si de of nes and risers peen all valves In mains, bech B. Access Panels: Provide to service valves, dampers, motors, aY vents or other concealed equipment. C. Escutcheons: Install at all h d uncovered r0 , or aces where expose piping posses th �' h walls floors ceilings. D. Galvanized Iron Sleeves: Not less then 20 gauge, cast In concrete Installed shall piping passes through concrete floors or sells. Sleeves for Insulated pipe shall be of sufficient size to allow the covering to pass through sleeve. Use steel pipe extended I" above finished floor for sleeves in floors of rooms exposed to water. For penetration of floors and malls from burled pipe, acwlk, annuls between ape and sleeve with first lit Kull and O il with Itch_ space pp quality p MECHANICAL SUPPORTING DEVICES A. General: Mechanical equipment aid materials are not to be suspended or supported from pipe, electrical conduit, ceiling systems or any non- structural member. a Pipe Hangers and arts Item selections, hanger spaci gs, rod diameters, and protection shields n accord with MSS 5P-69, except as otherwise Indicated. pipes shall rot be hung our supported from each ?other. G. Concealed Piping: 1" and smaller may be hung with pipe straps_ a MN :p Supports: Where mber plpeung wit supp ort eg: trapeze Mrger), a nu sAanit des «Iter la are /wlhcvlah tion. a common E. Structural Attachments: Beam clamps where possible. F. Vertical Adjusting Device: Provide on all rigid hangers. G. Protection Shleld/protectlon Saddle: Use on Insulated pipe, H. Risers: Provide support at tee or elbow at base of risen. Provide pipe damp support at each floor. I. Duct Hangers: Install In accord with SMAGNA Low Pressure Duet gem`+ Construction Standards. P rby coatSupport snot at wall or Naar and fill aroma mat 3.04 IDENTIFICATION A. Equipment Nameplates- Affix prominently on ecup eat except in Fn sled areas (e.g. un t , ' offices) where namep rtes shai be inside access pane. B. Pipe Marking: Every 50 feet, at wail or partitions, and at pipe junctions . Lettering oriented to be read from below horizontal centerline. Post sprinkler room. G. Valve Tag Index: Post under glass or p, 3.05 INSJLATON A. I. Pipe Insulation Domestic cold water: 1/2" b. Domestic not water f' 2. Supply and Return Duct Insulation: I I /2" B. Installation 1 A - when building thoroughly dry t shrinks Apply covering w g is g y y o proven shrinkage. 2. Apply Insulag emn a ves qual to adjacent oh!ekn¢ss and tin fle e with t p reFprmed all flttings P` /c nd Fittin Jackets 3. Insulate all risers, branches and connections to equipment. 4. Insulate d protection saddles shields. pipe a t hangers an provide pro or 5 Do not insulate direct burial or cold water. 6. Do not insulate over equipment data labels_ 7. Secure duct wrap with mechanical Fasteners spaced 12" on center, minimum. p shall For mech ducts pe r our ace In wi duct core h 11 also be secured ith mechanical fasteners spaced IB" on cantor, on centerline of bottom of mat. 8. Insulation Is not fawned an sound lined ductwork of eufflclont R- valve. LND OF SECTION SECTION 5300 - FIRE PROTECTION SYSTEMS PART 1 - GENERAL 1.01 GENERAL REQUIREMENTS A. Conform to the General Conditions and the General Requirements. B. conform to requirements of NFPA 13. qe 02 SCOPE This section includes design and Installation on modifications to the ex!st'ng sprinkler systems For building Ere protection. PART 2 - DESIGN 2.01 SHOP DRAWINGS Develop In accordance with NEPA No 13 and the local Fire Marshal. Include detaq vndsrprinklerr tms Includng ctionseanddntrolot plan showing group supply connections, valves, fire department connections an d other equpment to be used. Drawings shall show sprinkler heads, piping, piping supports, earthquake protection as may be required to Formally meet all requirements of NFPA and approving authorities. 202 SPRINKLER HEAP LAYOUT conform symmarlcal pacing and integ ocallb of s anth celling d ev ices. C s heads an calling tiles rate ( and l alig n in str rowsd o. er 2.03 `SUBMITTALS Submit shop drawings to Architect, Local Fire Marshal and all other approving authorities. Drawings shall be approved bj all agencies prior to fabrication or Installation. Drawings sub Architect's for chltecC's approval shall have been stamped by Fire Deportment. PART 3 - PRODUCTS 301 PIPE AND FITTINGS Schedule 40 black steel or thlnwall pipe with cast iron or malleable Iron screwed fittings or grooved end things. - 3.02 SPRINKLER HEADS A. Pendant: I/2" mole thread, polished chrome finish and ordinary temperature rating (155 Viking Model M -1. B. right: Standard type with I/2" male thread, standard brass finish and ordinary temperature rating (155 °). Viking Modal M. C. Semi -recessed: 1/2" male thread, ceiling escutcheon, white finish and ordinary temperature rating (155 °). Escutcheon. Viking Model E -I. Head: Viking Model M. 303 SPARE HEADS AND WRENCHES Provide heads In accordance with NFPA s13. Locate In sheet metal cabinet. Provided "Automatic Sprinklers - Reserve Supplies." (V „.0 0.0 ()F v F. RD ■ PART 4 - INSTALLATION 1 �y9 00 I (5 f�' 4.01 Installation sh b e In accordance with NFPA el' N 402 Install semi- recessed sprinkler heads where p concealed, I. e dry t' :x' wall or acoustical the ceilings. CEIVED 403 Coordination of work shall preclude interferer other piping, CITY f N ;l::°::::: ciaJ 4.04 we1 BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON REVISIONS 1!QEII[�EEl[T ( 110 DA. WA 90004 (206 027- 100 PRINT DATE 08/29/96 092'7 DRAWN BY: SHEET MPE2 OF o TEU GGE 1 AGEL DRAWING NAME ® " "B AI CIVIL ya aCTo INC. Evergreen One, 10940 NE 33rd Place, Suite 202, Bellevue, N le ®f Bei1990 PROJECT NO.: 96,231 BECT 15400 - PLUMBING SYSTEMS PAR` - GENERAL i 01 GENERAL REQUIREMENTS Conform to General Conditions, the Modifications [hereto, General rements Requi. 1. SCOPE A. This section includes piping, fixtures, equipment and accessories. E See Kitchen Equipment Flan. Kitchen Equipment Schedule and Kitchen Equipment Rough -in Plans for specific requirements. PART 2 - PRODUCTS 201 WATER PIPE AND FITTINGS A. Above Grade T "L ", hard drawn co Sr wrought c° Fittings; ; 95 -5 solder. Chrome- plated Crass for copper piping to fixtures. 6. Below 6rgde. type "K soft temper copper, 95 -5 solder. 202 HOT WATER HEATERS (GAS) State model SET- 50 -65NE, 50 gallon, 65p05 BTU gas Fired. Provide IX-Strut Hangers to support platform For water hooter. - 203 WASTE AND VENT PIPE - UNDERGROUND A. Cast Iron bell and spigot, long pattern fittings. rubber ring Joints. B. Gast Iron, fie -hub, long patter fittings, stainless steel sleeve joints. G. ASS Plastic Sewer Pipe, solvent cement joints. 204 WASTE AND VENT PIPE - ABOVE GROUND A Gast Iron, bell-and-5p got. long pattern fittings, rubber ring joints. B. Galvanized, schedule .0 long pattern recessed O.I. screw fittings. c. DWV copper, long pattern cast brass Fittings - 50/50 solder. D. Gast iron, na -hub, long pattern fittings, stainless steel sleeve Joints. E. ABS Plastic DUN, solvent cement joints. 205 GLEANOUTS Wade, Zurn, J R. :math or Josam equal to Wade models listed. Nloanovt 0000 -2 -15 bronze tapered thread plug. -Floor Cleanout 6000 -TS -1 NIe floors -Floor LleanoeF 6000 -2 -12 with carpet marker bronze -Wall Cleanout 9590 -E /R plug, chrome cover 206 FLASHING AND COUNTERFLASHINA 3 lb. lead soldered Joints and seams, 24x24 base pad and eaunterflashed into pipe. - 201 TOILET FIXTURES AND TRIM A Water Closet: Floor mount, t flush tank, ADA configuration, open seat 6 cover. American Standard 2108 -100 or approved. B. Urinal: Wall mount, Flush valve. American Standard 6540- 011/Sloan I90-IS or approved. FIXTURE FI %RE SUPPLIES Install for all required fixtures, equal to Speedway Flexible Supplies SR1T15A or similar loose key stop t applicable to specific fixtures. y s p ype as app spec 204 TRAPS j type as app peci . Adjustable applicable to specific fixture. A Ad 3. Provide trap all Floor drains and Floor sinks. Provide access Fe p primers on a primer valves. 2IS FLOOR DRAINS A. Kettle: Zurn "3- 1030 ", 6 in hub for Indirect drain pipe with no strainer. B. Layout Table: Zurn "213-415" with Type "B" polished bronze 5 Is dia. strainer and '25.525 p in polished bronze funnel, 4 In. top dia. to 2 1/41n bottom die annd d S-S 3 -3/4' . height. C. Main Kitchen Drain, Soda Dispenser Drain: Zurn "25-415" with 5 M. dia. polished bronze strainer. D. Walk -In Cooler condensate, Soup Kettle Condensate, and Ice Machine indirect floor drains: Zurn "Z-326" Indirect waste Funnel with Fixed air - 9°P 211 GREASE INTERCEPTOR Zurn "Z- IIIOIL ", Size 500. Verii anchoring access dons with field conditions. Verify uct compliance with local health de department regulations or whether unit Is required Fred local codes. p° gv 0.v by PART 3 EXECUTION 301 WATER SYSTEMS A. General: All piping shall be concealed where passible. B. Grade: Grade piping to drain at Los points. Provide hose bet, IF low point Is not a[ plumbing fixture. G. Exlariar Walls: Install water In piping on Interior side of building Insulation. D. Cleaning: clean pipe prior to testing bu thoroughly flushing with water until all dirt and foreign materials have been removed_ Maintain flushing operations For not less than one boor and until piping is clean. Not less than 80 psi flushing pressure. E. Sterlliza1l Slor111ze pipe with chlorine before acceptance_ Apply amount of a� ham: Ina uc w such as proves a dosage of not less than 50 parts per million. After a contact period of not less than 9 hours, flush system with clean water until p parasol chlorine content is not greater than 02 orts per minion. open all voi s s In m li ones being sterilized and close several [Imes during contact period. r. Testing: Test pipe fora period of not lass than 4 hours 50 pslg above wilding operating pressure, no pslg minimum_ ) 302 WASTE AND VENT SYSTEMS A 6rade: Grade at 1/4" per foot he possible, but in no case less than I/8" per foot. B. Vents Flash and counterflash Install vents passing through roof with r n9 g assem roof flash/ and co unterflashln assembles. C. Cleanauts: Provide every 50 Feet and install at all locations required by code and to permit cleaning of all waste piping. Provide cleanauts full z e of pipe, wt not larger than 4 "_ coordinate with Architect stem c' graphite. Locate demons ho clear cabinet work and to be easily accessible. D. Testing h Subject a all work to an tfor kin Id of 10 Peet head of water. Notify Architect at least 2 normal wor king days prior to testing_ E Approvals, Is: Obtain written a to pro approval of local plumbing authority y prior csg o concealing any work. over r F. Plastic 40 gallon n pipe maybe used to all areas except sink, 40 feat downstream of the 40 gallon bagel kettle and Its adjacent floor sink SOS PLUMBING FIXTURES A. Exposed Piping at Fixtures: chromium plated. B. Cou-,ten-Tap Sink (where applicable): Verify with cabinet supplier peon to mitering C. Fixtures and Equipment Furnish all traps, valves, tailpieces and other trim not furnished with equipment. D. Shut -Off Valves: Provide on all water lines to fixture giro ps. E. Fixtures, Locate In accordance with details on archltectvral drawings and/or Architect's direction In field. Fixtures and a tin accord with F. Fixtures and E t. Align g architectural daarving n . Flt fixtures on finishedwa without noticeable warpage on either the wan or fixture and grout with G.E. sllicane or similar approved material. 6. Water Connections. Install individual loose key stops all Fixtures. If water convections are concealed, Install valves 9n lieu of sstops. END OF SECTION SECTION 15480 - NATURAL GAS SYSTEM PART I GENERAL_ 1.01 GENERAL REQUIREMENTS A. conform to General conditions, the modifications thereto General Requirements. B. Comply ith requirements and recommendations of NFPA 54. p y qv Ip2 SCOPE OF WORK A. This section Includes piping, gas assoclated all l as necessary cns and ecess for and natur a l gas service. coordination with local gas compan, all a necessary for natural B. See Kitchen Equipment Plan Kitchen Equipment Schedule and Kitchen Rough -In Plans for specific requirements. PART 2 PRODUCTS 201 PIPE AND FITTINGS Schedule 40 black steel with malleable Iron screwed fittings. 202 SHUT -OFF VALVES Ball valve equal to NIL o T -560-Y 2.03 PRESSURE REDUCING VALVES High t Its designed and rated For natural d std Ice In accord g capacity un gee gas second stage service with ANSINL Standard 144. Units shall have spring loaded regulations and Internal relief valves. Fisher series 5102, 5202, 5302 or approved. FART 3 EXECUTION 30 1 GAS METERS AND DISTRIBUTION Coordinate with bas Company. Peg all charges necessary For complete Installation. 3.02 PIPE AND FITTINGS A. Grade horizontal pipe not less than 1/4" In 15 Feet. B. Provide 6" long drip leg at bottom of vertical pipe. C. Take From top or side of horizontal pipe. D. Do n ot e mbed a ny building service low plea in concrete, in ma or below grade. Install such pipe In wpressure e sleeves. 3.03 PRESSURE REDUCING VALVES Install on equipment as required for pressure modulation. 3.04 TESTS A. Perform In accord with NFPA 54. B. SbJect pip to air pressure of 6O pslg For 3o minutes with no perceptible dro In r ca re. P P 8 END OF SECTION 13 (0 3 I SECTION 15800 - HVAC SYSTEMS PART I GENERAL 101 GENERAL REQUIREMENTS Drawings and General Provisi Specifications section apply to Lot SCOPE OF WORK A. mi cs secotndtiion onInincWtemdep as sign aig sys B. See Kitchen E t Plan, Rough-in Pens for specific 9 in pet 103 CRITERIA A. Indoor and outdoor temperatures for with the latest edition of the Wahl ton C ode. Heating t capacities shall n9 egvipmen B. Minimum Toilet Exhaust ES CFN/ sq. ft. C. Minimum Gaoling Criteria I. LI W/sgFt. lighting 2. 05 W/ .Ft. miscellaneous 3. 100 sgFtlocwpent 4. IS% sensible cooling safety Factor. D, Exhaust Systems: am I, 40 Gal. Kettle: 1000 m for ood having three or fewer stainless steel hood equipped and clearable Filters. Provide Incandescent Flt with Leman 2. Bagel Oven: 100 CFM Hood see section 114001. Existing HVAC units may be configurations of any existing design of the HVAC system. PART 2 PRODUCTS 201 ROOFTOP AIR CONDITIONING UNIT Air -to -air single pockage unit refrigerant compressor, atural All equipment factory assembled, ready for Field connections. Trans, Accessories: au Po. - Roof mounting heating and coaling - t seb auto-changeover Disposable psep l e a te. - pleated fabric UN relief - Economizer reief - Emergency h eat control. Emergency heat colack - Anti-short cycle timer. 202 MAKE -UP HEAT AND VENT UNITS Packaged rooftop blower coi 9e top heater, filters, motor and accessories manufacturer with AMCA rating Accessories Stainless steel heat exchanger. - 2 -stage gas control. 2° disposable pleated fdxle _ 2-stage thermostat. 100% outside air inlet hood. 203 CEILING FAN r fan mounted M Insulated and UL approved. Gom, Accessories: - Variable speed switch - Integral telling grille. - ckdraFt damper_ - Disconnect switch or plug. 01 2.04 ROOF EXHAUSTERS centrifugal fan In spun aluminium approved equal. 205 METAL DUCTWORK A. Standards, Comply with f FFasss e Duct Metal dew Pressure Duct Construction duct, Fittings aid accessories. B. Materials: Galvanized 200 FLEXIBLE DUCTWORK A. Standards: Insulated Lengths not to exceed B . Materials: 6 -KM, Flewnaster of Contract including General work of the section. end equipment far the heatng, ventilation and Kitchen Equipment Schedule and Kitchen cep "remen s_ hood and ventilation requirements winter and summer shall be in accord State Non - Residential Energy be 150% of calculated_ Island Food and 1400 cfm for sides, Type 304 18 gal. with baffle-type removdole hood with one UL- Listed globe. provided with Bagel Oven reused. Contractor to evaluate capacities and units and the appropriateness of their reuse in the with evaporator tan and coils, condenser fan and calls, heating section, controls and accessories PART 3 EXECUTION 301 ACCESS Install equipment with associated ductwork a piping to permit access to doors one panels as required for periodic mainten nd once (a g. filter servicmgl. 302 INSTALLATION t In accord with manufacturer's recomendations. Errng conflicts Install e quipmen m between such recommendations and drawings to immediate attention of architect/engineer. 303 FILTERS Provide one complete set of Filters. Use exisllna filters during construction and one replacement set to be installed For Owner at time of occ',nancy. 3.04 Existing ductwork- contractor may reuse existing ductwork (metal and flexible) in accordance with good design and installation practice. Flexible ductwork lengths shall not exceed o-o nd a shall be supported at 56" on center. END OF SECTION SECTION 16050 - ELECTRICAL Electrical subcontractor to provide and Install all rough -In and wiring required For telephone and data lines. Plans shall comply with the National Electric Code, 1993 Edition, The latest Washington State Administrative Codes Including the Washington State Energy Code, 1994 Edition as amended by King County, WA. SPECIFICATION STANDARDS I. Refer to sheet E -I and Kitchen Equipment schedule For equipment requirements. 2. See sheet E -1 and Kitchen Equipment Schedule Far requirements. 3. Lighting Design Requirements: Refer to sheet A1.0 for lighting layout. 4. Light Fixtures: Refer to lighting fixture schedule on sheet Al 0 for lighting Fixtures. NOTE: Provide emergency lighting as Indicated, unlesT otherwise roquired by local codes. SPECIFICATION REQUIREMENTS The Electrical Work Section should Include, but not be limited to, the Following Items. These items ace For outline purposes are are not intended to be spec re fic cub titles within the Final Section. Basic Mate -,..is and Equipment Include motors and motor controls, over current protection, conductors, raceways, supporting devices, wiring devices, and disconnects. 2. Service and Distribution. Include temporary power, Incoming power service, equipment, fig, grounding, service n ical r to food service equipment, mechanical equipment, and other devices devices, and al s ere ce requiring electrical al servi. Provide din Ice disconnects, switchboards and Iboards, overload protective. a Provide Ion cUl Titer l with trim h aving adjustable mounting clamps and keys for en cylpaer locks and catches Key all panels alike and provide two Pros for peh panel. all devotes laminated b lack n typewritten lw i with white ett inside each o normal door nameplates wth whi lettering for noal power evies and laminated black d red nameplates with white lettering Por emergency power and systems for panelboards, lead centers, disconnect switches, transformers, motor starters, end of Inc I switches, and other simllm devices and equipment with complete schedule of legends submitted for review before installation. c Run all conduits concealed in walls, floors, or callings, whore building construction permits. Use exposed conduit only where acceptable to 2ruagger's Corporation. Accurately locate conduits In partitions, Fully concealed with no exposed conduit bends at floor or ceilings. Coordinate conduit placement Filth other t rades to Ids chases for conduit In masonry Its, whore a lcable. provide y wa pp I Provide stainless steel rosettes at Finish wall penetrations. d. Provide wiring devices (receptacles, switches, and other similar Items) of specification grade, snow white plastic with matching plates, except Bake Area where brushed chrome plated units aro required. Provide switches of quiet make/break type, rated to match amperage of circuit breaker in panel For that circuit. Provide cast iron cast aluminam, or m d steel outlet boxes for each ite of e n, electrical equipment for convenience outlet receptacles, wall switches, lighting fixture outlets, and On devices indicated or required. f. Switch all bathroom vent fans with lights. g. Exterior lighting to be on power timer located in office or on photo cell, as directed by Franchisee, 3. Lighting Levels. Provide lighting levels For each type OF lighting fixture scheduled and o /space to comply with the Following guidelines. a. Kitchen Areas: 50 Fe. b. Food Preparation /Govnter Areas: 40 fc. c. General Lighting - Public space: Minimum 20 fc to maximum 50 fc; Incandescent fixtures on dimming circuit. d. Exterior Building: Minimum 3 fc For walkways at entrances and building front. e. Parking Lot: Minimum I fc, with fie accessible public areas below 1/4 Fe, vsiiv HID te lighting with sharp cut -off style housing and photo -e controller. _ Check Lighting poser allowance Form. 4. Communications, Include telephone, Fire alarm, and security. Controls and Instrumentation: Include indicating devices, starters and motor control centers, Fire actuated, temperature actuated, limit switches, time activated, smoke and heat sensors. b. Allow sufficient space in mechanical and electrical rooms to allow for operation, maintenance, and/or replacement of equipment. pen en y g a quipmen , conduit and I i h[ Fixtures From building 1. Inds d N hang all electrical equipment, g g structure. 8. Use only copper conductors 9_ Food Service Equipment Electrical Requirements Provide electr services to motors and o heating elements having the Following electrical characteristics: Motors I/O HP and Smaller. 120/1160. F 0V� ✓✓ � -P V Motors 3/4 HP and Larger. 200/5/60. c� /9 9 R A N - / Heating Elements 500 Watts and Smaller: 120/1/60. v Q V a Heating Elements Over 1500 Watts. 209/3/60. P \496 D(,1 .. "' f V)STOCI END OF S ECTION /' pOL -3O e�Ll RE clTV o ruxwlu OCT 0 2 149 f PERMIT CENTER gas piping precharged, piped and wired "Eternally, tested and Cannier, Lerwox or equal. auto-changeover thermostat with night do . e rs s . 50('.0 damper unit consisting f Insulated ecbimt fan, m bural 9 ° gas as indicated below. All components by the sane and UL approved Trans, Rezrwr or approved. Pilfers. Farr 30/50. cabinet suitable for ceiling retallakian, AMCR WTme. housing AMCA certified, UI-- Cook. Greerheck: most stringent requirements and recommendations end Air Standards Contractors National lee end sealant Standards for Fdxknbm, construction and sralmt of sheet steel, ASTM A521 assembly with vapor barrier and UL approval. I0' -0"_ or approved. BRUEGGER'S BAGEL BAKERY SOUTHCENTER PLAZA TUKWILA, WASHINGTON REVISIONS 1N�PIE11111IEIT 110 WA 98004 (208 n 829 2100 PRINT DATE 08/29/96 0930 DRAWN BY KAL SHEET MP E3 OF �/ I ��V LSd�� 0 AY 1y/� i1���. \l0 --- DRAWING NAME 1623 " DATE: J � M J � - -- _ E vergreen One, 10940 NE 39rd Place, Suite 202, Bellevue, PROJECT NO .. 16231 SYMBOL LEGEND, " GOLD WATER (CW) • HOT WATER (H.W.) O DIRECT WASTE • INDIRECT PASTE O NATURAL GAS ® FLOOR SINK (FS) ® FLOOR SINK W/ HALF GRATE O FLOOR DRAIN (FD) SOUTHCENTER PLAZA TUKWILA, WASHINGTON NOTES: I. THIS PLUMBING ROUGH -IN IS FOR EQUIPMENT FURNISHED BY THE KITCHEN EQUIPMENT SUPPLIER ONLY. ROUGH -IN REQUIREMENTS FOR EQUIPMENT SUPPLIED BY OTHERS, OWNER OR GENERAL CONTRACTOR MUST BE VERIFIED BY THE GENERAL CONTRACTOR 2 CONNECTION FROM ROUGH -IN TO FINAL WATER AND DRAIN CONNECTION ON FOOD SERVICE EQUIPMENT TO BE BY GENERAL CONTRACTOR 5. ALL DIMENSIONS SHOWN ARE FROM FINISHED WALL SURFACES. 4 ALL LINES TO COME OUT OF WALLS OR FLOORS AT HEIGHTS INDICATED BY ^e" INCHES. IT SHALL BR THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO INSURE THAT ALL UTILITIES AND CONNECTIONS SHALL CONFORM TO LOCAL AND APPLICABLE CODES. 5. ALL UTILITY LINES SHALL BE CONCEALED IN WALLS UNLESS OTHERWISE NOTED. 6. ALL HOAG WORK TO BE BIDDER DESIGNED. 1, REFER TO SPECIFICATION MANUAL DIVISION 15 FOR ADDITIONAL PLUMBING 6 MECHANICAL REQUIREMENTS. B. ALL HVAC WORK AND FIRE SPRINKLER WORK TO BE BIDDER DESIGNED. BRUEGGER'S BAGEL BAKERY PLUMB I NG ROUGH—IN PLAN SCALE: I /4 " =1' -O" 3 0 PVC CHASE FOR SODA LINES FROM ITEM 0I TO ITEM 19 Lv I'-N° i // i n i Y, Y i n i i v i i i i i i i i ti I/2° CA 6 HA FLEX LEES TO KETTLE FAUCET ITEM I DRAIN TO NE BELOW SLOPE FLO TO DRAIN I' GAS (250 00 BM FROM ABOVE ITEM 3 E INDIRECT WASTE TO FLOOR SINK ITEM 14 1/2" CA. L _) L. I/2" CW +24" ITEMS 346., 35d I° INDIRECT WASTE TO FLOOR SINK BELOW (2) 1/2" CA N HA NIX° ITEM 16 ROUTE 2" INTERCEPTOR OUTLET TO FLOOR ASINK AND TERMINATE NV AIR GAP, CA TIPFLY ITEM 02 114° INDIRECT DRAINS TO FLOOR SINK EB.OW ITEMS 01, 02 NOTE: COORDINATE WATER SUPPLY, DRAIN LINES AND POWER FOR ESPRESSO MACHINE WITH UNDER COUNTER REFRIGERATOR 4 CABINETRY. 11/2° INDIRECT DRAIN TO TRENCH DRAIN BELOW ITEM 4 ITEM 65 MOIRE FLOOR � C / I I 1 I J I ® N I INDIRECT WASTE I ' TO FLOOR SINK ITEM 240 I /� I/ \ RECT WASTE TO FL RE - SINK BELOW ITEM 24a 1 CW 4 HA H0" 11/2° WASTE +112' ITEM I0a 1/2' INDIRECT WASTE TO FLOOR SINK BELOW ITEM 34a I I/ INDIRECT WASTE TO FLOOR SINK BELOW ITEM 53 FOR SODA LINES FROM ITEM 19 TO ITEM 01 M1 g6-OGYJ2 Q.EH _E Io tenter 010 .31q4) 41') o m \�F o 3 G GEET 13AGI11.4 Doi asap 9A K@ 4 N REVISIONS ADDENDUM 92 REVISIONS 9/24/96 ADDENDUM 95 REVISIONS 9/26/96 PERMIT REVISIONS - PUBLIG WORKS ���Y�//�,!�y T OyJI��'�,QE /ME(l[T(�"y H 110 d1QCH ECT89 INC., DA Evergreen One, 10940 NE 33rd Place, Suite 202, Bellevue, WA 90004 (206 627 -2100 Q a U-P ao DRAWN BY: KAL DRAWING NAME: 5620100 DATE: 10/1/96 PROJECT NO.: 96201 SHEET OF P1