Loading...
HomeMy WebLinkAboutPermit D04-416 - LAW OFFICES OF SMITH HARRIS - TENANT IMPROVEMENTLAW OFFICES OF CHERYLE SMITH HARRIS 320 ANDOVER PK E D04 -416 Z re W D• J C)• 0 W= J WO u. =W ? E- O Z 1- U0' oI- WW u'O. Z: W 0 U =. Z Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Value of Construction: $8,500.00 Type of Fire Protection: SPRINKLERS /AFA Type of Construction: VB Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: doc: IBC - Permit City oi Tukwila Parcel No.: 0223200060 Address: 320 ANDOVER PK E TUKW Suite No: Department of Comm rniity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206- 431 -3665 Web site: ci.tukwila.wa.us LAW OFFICES OF CHERYLE SMITH HARRIS 320 ANDOVER PK E, TUKWILA WA CENTERPLEX 331 ANDOVER PARK EAST #100, TUKWILA WA DAVID SEELY Address: 7983 LEARY WY NE, REDMOND WA Contractor: Name: KELLY THOMAS INC Address: 3402 C ST NE, SUITE 209, AUBURN WA Contractor License No: KELLYTI148CR DESCRIPTION OF WORK: INSTALLATION OF INTERIOR WALLS AND ALL INTERIOR WALL AND FLOOR FINISHES. INSTALL 3 DOORS 1 RELIGHT AND ELECTRICAL (UNDER SEPARATE PERMIT) N N N N N N N N N N N N DEVELOPMENT PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 881 -7506 Phone: 253 - 735 -3928 Expiration Date: 01/29/2006 Fees Collected: $346.41 International Building Code Edition: 2003 Occupancy per IBC: 0008 Number: 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: D04 -416 Size (Inches): 0 Public: Non - Profit: N Public: Steven M. Mullet, Mayor Steve Lancaster, Director D04 -416 12/23/2004 06/21/2005 Printed: 12 -23 -2004 z • w O 0 O 0 U) ILI J = t- U) u_ . w w Q _ ° w Z = r^ 0 z t— w w U� O I— w I- u. O ..z w f:: F` z k; .t,:(.,I;E:;., +kW; Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating c• • u • • • the pej ormance of work. I am authorized to sign and obtain this development permit. Signature: G Date: 2/2 M Print Name: doc: IBC - Permit City col Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: ci.tulnvila.wa.us Date: Iz.2 %Z3 y e...k 1/4. \/\ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D04 -416 Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: D04 -416 Issue Date: 12/23/2004 Permit Expires On: 06/21/2005 Printed: 12 -23 -2004 Z Z _ cc w J U O 0 U CO MI J = r~ CO W W O • Q - d = W H = F— O Z I- w U� O- 0 — W UJ 1-- H L I O Z U O F " Z le • City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223200060 Permit Number: D04 -416 Address: 320 ANDOVER PK E TUKW Status: ISSUED Suite No: Applied Date: 11/19/2004 Tenant: LAW OFFICES OF CHERYLE SMITH HARRIS Issue Date: 12/23/2004 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: A Certificate of Occupancy shall be issued for this building upon final inspection approval by Tukwila building inspector. 9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) doc: Conditions 004 -416 Printed: 12 -23 -2004 z w CC LI 6U O 0 N O J ii-- N LL w 0 L Q i r- w Z I0 — ILI • W U � O — C1 H wW LL. w z U= O 1 ' z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 15: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 16: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 17: ** *MEANS OF EGRESS * ** - IFC Chapter 10 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 21: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 22: ** *SPRINKLER SYSTEMS * ** - IFC Chapter 9 - NFPA 13 and 25 23: Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. (IFC 901.4) 24: All new srpinkler sysetms and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 25: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 26: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1900 - NFPA 72 27: Maintain fire alarm system audible /visual notification. Addition /relocation of walls or partitions may require relocation and /or addition of audible /visual notification devices. (City Ordinance #2051) 28: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) doc: Conditions D04 -416 Printed: 12 -23 -2004 • City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 29: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #2051) 30: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 31: ** *BUILDING CONSTRUCTION * ** - IFC - IBC 32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 33: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 34: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Conditions * *continued on next page ** D04 -416 Printed: 12 -23 -2004 z " w _ . U U O W WI C0 w ° u. Q Nd =w z F O Z F- U O — W U J II O co O ~ z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or regulating construction or the performance of work. Signature: Print Name: doc: Conditions 3 f/"N 0. D04 -416 as outlined. All provisions cancel the provision of any Date: of law and ordinances other work or local laws Printed: 12 -23 -2004 z w re 6 00 co co W: 1— U) u. W O. u. I O I I- O. Z I--. tu .O N 0 I— CU W . 1 0 H . O. Z. O ~: .z Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Voolicationitnermit nnnhration (1.7nnal CITY OF TUKWILA Community Development Department Public Works Department • Permit Center 6300 Southcenter Blvd., Suite 100. Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: Oa- Z 3 2.0 - CO (O Site Address: 32.0 P NDO v iQ PA, E sr Suite Nu�mb I D : Floor: I $T L.P.A./.3 Tenant Nam L.P.A./.3 0 FF(CGS O F C}A E12.`< LE 5 VA 1T + Rt New .... Yes D ..No Property Owners Name: WA • 0-, IOSug...l -tQus. Mailing Address: P. 0 Pjbx ?,p T l OLL p,, City Name: NW \D S - L`{ ) 1 14 • Mailing Address: 7 ct 8 3 L E ( -" CA-) E -Mail Address: da y A e-r-4 co Company Name: Mailing Address: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** n��%;.:- , 'S�ti i ;;: ,icti }i�:� �.'�." 1�•`s�%A'�:c kj .ri+i.•Y�i4��,!�iF- {? =� , rt,; lans must he4W,e stam y lr; t,;�.ri c'- -1 i t +t lit ✓.ra: <,,,a ,ti tird� Company Name:. T D RA\ F-T 1M :Ey Mailing Address: 7 37, W k 0 A N W 1\ l 8 0 5',2_ L City Zip Contact Person: D N V l S E Day Telephone: 4 Bet - - 25 - C-DL E -Mail Address: d6..v i (o r i e -r , M Fax Number: *g. . — 8 31 — O Day Telephone: k Sd R moat W I\ `t City State Zip Fax Number: 8,51 O CD City Day Telephone: Fax Number: WA State State State 138 Zip Zip 44 •314. 4:r. i '�o- H� + $3 ...AA l�..i�.e'T�v: "r.. v1e ': .. ; 'l l i �`.��l C ' t �'Y1 {• ^ }''�uij Liar V%ar. .!. ,,,.. �,.. �... ..:.:r;:'1L` ank ;nius' l e ` efet stampe Zip City Day Telephone: Fax Number: State ftri. V/t14. 83S tr Yfyit, rynyesrx4ws+ r. t ets Z Z 6 i O U O J E- • W W 2 J w j w a w Z � I- O Z I- w U � D I- W w H � L Lu Z U N H� Z i • .'',' i� :,.Yl !�• .0 . }.: }.' �'.r,• :2 . 1•:�.,i_ i 9. ixi i, i, .{�y. + t � t , . �� .:i +�: :r�"' ", •L ..( .�;r; ..u��' ,; �!•_;. -i ;� � S Ektst in g ..::... �1� . ::I.i� !t �f , �'1 ,. a,. ? 4: ; • ;• ' �. �r LF'���, .- 1 : #� • tlntertdr , i .. , tt emode ± , R � •�„ i���� 1 •ty ' +to.,.. � ([�, fl '' ... .ar' * .lt;.. i ._, , . } ,.is r ! Structure Y I F.1•K, � ° }: � C . �' :,.,.,- ,':,h „. +. ti i +� � ,. � ?. ' , :G�'i ' t h rh .r n.A�' r i tti�r „ �' Nevlr 2 V i i+ S 4' :����:�� �e.oE:.Fi.�.�” ;..:.:,. r7Y F' 1rt', �, n ., lib r �� :T. ,, iw::� , Constructton : '< per UBC 4 '.Y', : -•i�'r . ,. • T'• eof: • 7.. i + { ..4.....A �r r � '�,i . •- c • =. ■ O an t e r` coup ype LJBG V ;. 21a Floor - rir1: � .::..; r t loor,::' Floors : thru r '' ■;130 nent < :; 4 ' 'i Accessory .S a *! ':'Attached :Garage:;;;:;: ': ':':'_'' Detached: Garag Att ached .Carport" ;;:Detached -Cargo rt Ceriered�Dec ": :Uncovered Deck: Dly V':tJ,1l:7Jt\l�l' •,l," iV fry yl,lJil6 VV J.•1= r uV,a(�\l;r� •r U `r � r L ,, v, ,yy(��• t �'�L a� y . Z rte ..y: ,(� �i ..� � J i ><� � q , �,y',.!}��f �� t � '�i�l�i:�f,�:��if�,�4: S t 4 �'t ",; ^ "{ Vii- aj r4 t i;J ' i'Z ' t i f 9.... ri f� ' ig r i 42: i s ti .. �. '! » E' i alig L '�J 1 •. p. •'' i , +' '.(Y r•: a m�}+.,••.R t t t + [�' jy '!� / � } ,p ; i(�� Ar.S' e `4� r��' I fie{ � 4.!.l.i...�.� as t �. �•�����F {.c .:+4� 34� l�. .�,� � �Y..11. ,•!!1:.. �.:•',1 �i�� .v.� .�P,jrR� 1..Y'.1� :�!C:.� ���5.. = ^� wit. Valuation of Project, (contractor's bid price): a I Soo ' ' . Existing Builutng Valuation: $ - 1 ° L.5 - 1 coo Scope of Work (please provide detailed information): IN 5 -t_. l NT l,O w p4LL.S 4 4LL_ Will there be new rack storage? Ej ..Yes A. No If "yes" see Handout No. for requirements. ;it'avide:All Buildiii Aireas ia; uare ;Footage;Belo�t!;' PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 131 71 Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? 0 ....Yes FIRE PROTECTION/HAZARDOUS MATERIALS: 14Sprinklers ..Automatic Fire Alarm 0..None lapplicationslpermit application (3.2003) 3/2003 w p►i - - 1-oo. F N . ' ' s - t .. t1 . • L ' G tf 1i. Compact: Handicap: o If "yes ", explain: Page 2 .;•.;..:, a:. �; u;:•. �: tc :�.::.rt�:es;•;.:uz,•..w,trs.'. . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0..Yes .No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material a ety Data Sheets. ntt .;yP.e? : }; ,'4,. QtY. Untt gybe.., _, .pF . ii Qty',. ',:-Unit'TYpe N;: r ,.. Qt !:F ;Boiler /C,ompressofct4,:: , _.:,, 0Q,, ,,' Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU . Furnace>100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15-30 HP /1,000,000 BTU Suspended /Wall/Floor Mounted Heater Ventilation System . 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm/Ind • • p � ,i1�"� r �,'.'" 1 ` x � Y�+t •�r�r � !{,,v :5n +yy e i /+2j• 1 w {• 7• ;; � r.','h�.• X44' +t•.;^.• . p ,; h f i?�y vg:4,La lf�.`.`�7,r, t zi �:. 4;4 1 d,1 , MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Commercial: New ....❑ Fuel Type: Electric [] Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: ef c . ...• •••• p S t pA1 licab1 L erl ts' c. » 1 :,y'S. t 4,1 . +.'s' .;• � Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. ' I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO''BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: I 0 R- Gte- ( - Mailing Address: 1 ' L ' . ut) Date Application Accepted: 9 -o Replacement .... ❑ Replacement .... ❑ .zd Os Date Application Expires: ` •�� t., �r ^" S1'ti �.' 3 do.1 {N City Day Telephone: Fax Number: Day Telephone: mo ND City State Date: (I /1 71 State 55(-- 7(o A `L Zip Zip 0 Staff Initials: * 4. 40 `ui! t0•`rlrs44!sw,+pr,K r�e•i++:r- rn�a +::au ,w� nw TRANSACTION LIST: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT D Parcel No.: 0223200060 Permit Number: D04 -416 00 Address: 320 ANDOVER PK E TUKW Status: APPROVED co 0 Suite No: Applied Date: 11/19/2004 w = Applicant: LAW OFFICES OF CHERYLE SMITH HARRIS Issue Date: -J 1- W 0 2 Receipt No.: R04 -01714 Payment Amount: 211.41 - c Initials: SKS Payment Date: 12/23/2004 11:16 AM H = User ID: 1165 Balance: $0.00 ' zi- t- O Z i- ll) u i Payee: WASHINGTON CITES INSURANCE AUTHORITY 0 N off WW I-U Type Method Description Amount • LIB - Z Payment Check 18527 211.41 U w O Z BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 Account Code Current Pmts 206.91 4.50 Total: 211.41 ,; ••7 r 7 / 7 _7.1 tT TOTAL 2i 1. 4.1 Printed: 12 -23 -2004 Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: Payment R04 -01563 SKS 1165 TRANSACTION LIST: Type Method ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 0223200060 320 ANDOVER PK E TUKW LAW OFFICES OF CHERYLE SMITH HARRIS WASHINGTON CITIES INSURANCE AUTHORITY Check 18425 BUILDING - NONRES PLAN CHECK - NONRES Description RECEIPT Account Code 000/322.100 000/345.830 Permit Number: Status: Applied Date: Issue Date: Payment Amount: Payment Date: Balance: Amount 135.00 Current Pmts .31 134.69 Total: 135.00 D04 -416 PENDING 11/19/2004 135.00 11/19/2004 03:42 PM $211.41 Printed: 11 -19 -2004 Project: 4410 0/P re of ('i�•r / / / „ /fs Type of Inspection: /= /AI /1 / Address: 3 a U A / 3 E Date Called: /- — 8 -4 . 1 ” - Special Instructions: '] p ` — v A r°'" -) 4 '## -Se Date Wanted: 2.—.�') - v5 a a.m. p:r Requester: 6 rar-1' \ Phone No: c � ? ,6- 74/67 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: yer- i;-/ 6 z rO fi w4) / Date: 0 REINSPECTION FEE �REQUIRE I�. Prior to inspection, fee must be at 6300 Southcenter B vd., Suite 100. Call to schedule reinspection. Receipt No.: Date: w QQ � J U O 0 N o CO 11.1 J = CO W W 0 g a _ d I-W z = I— 0 Z ~ U � co — i H w O W U= I--- z aiX�iaiv` 1•: v' Iq ;„�l���K(v+iPa�= ti:�i.�`;'::i% iii" � .'i:4'li�b�S.fic;ciwv.ijERz'i; � •n.v: g Project: b aeCalled 1 Type of Insp tion: Address: 3DO A- , • . . l iN (0‹ Special Instructions: Date Wanted: i - i j i/O p.m. Requester: � Phone ( -oL - MI — - Ng) Approved per applicable codes. ector: Receipt No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Corrections required prior to approval. COMMENTS: J 1 i 0 t- 1.L2hc.1 Date: c 8.00 REINSPECTIO FEE REQUIRE . Prior to inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Date: (206)43 1 -3670 A, �.i;%.;;:� zpi:i4:: '::,ai`t: t.... ._:LMtw..w:.wrv..+�. u+n+i� +usn.. µow. sw. rc✓ n.++ r+ ww 'wa.wwwr.M+...r+. +.w.wNM+.?.A� Project: t.-ptioj `'`' A c <.e, ► Type of Inspection: -A s l Address: 3 2 o Q.P.E. Date Called: 1 -L -oS Special Instructions: ( Date Wanted: 1 — 31--05 r p.m a.m.` Requester: ,Rhone No: 3.0k - 7S (0--) YS INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ector: bog -4/ Cv PER f 4 1 /1 (206)431 -3670 131A pproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Date: 1— '3l —c5 47.00 REINSPECT ON FEE REalIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: I--G ki) 04 ∎ () �, Type of In pection: L%c k tici w ( Old/015 Address: 3) -0 AL Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: 5 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pproved per applicable codes. Corrections required prior to approval. COMMENTS: I Inspector !' 9.. RoA.,94- Date: \ (71g...0 ..... $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project:) /� 1-Qua l0+ if P 4 Type of Ins ection: Y ' —Ce v\ Address: VO Ar'o. Tit. Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 a Approved per applicable codes. COMMENTS: Inspecto : INSPECTION RECORD Retain a copy with permit (206)431 -3670 Corrections required prior to approval. Date: , u 5 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: I n 1) `r \a r'Ci.v r ,P,- y- St 0-ovnAle Co %\ 'Ivvi trS n�( .'I i« s YN. 2.} +. y, L 1 AC't ✓∎ r'rn � - \rt, , , k 1 o�9nedv (r j !P(( Li, r,oet Reques er: /24/Liz Phone No: (2.6k0) 7Sro` 3 / -/ Project: /1 h e�ry 1k.. V $..} k d((lu Type of Inspection: , ;<S Inspection: _ / . ( �� Addres -��� J �J �/ y/ - 3Co A l� (V6:1 �a N (� Date Called: 0 /o /.• yo, i t Special Instructions: (C) 2.- . Date Wanted: _ a // /1/G)_ m. Reques er: /24/Liz Phone No: (2.6k0) 7Sro` 3 / -/ El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Q Corrections required prior to approval' Inspecto . < Date: `_ 0 iJ ❑ $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Z Z re W QQ= JU O 0 u)O J I- Q W O J ? co — F• Z � W C) • W U� 0- O t— W W 0 . Z Ili co 0 z Project: . ,. / e. , -) 4 -� -• '( 1 Type of Inspection: J� i('4,-.; .:7r 71 A� ( _�('(/� jc 'l'( Address:/ 4. r / ,,,e h L:2(,) �T�.. Date Called: / " !D - O S Special Instructions: r j J`' '' � =-'_. ‘ cr- (' d n , G, ..e.--..-- / r-v Date Wanted: / a.m. Requeste r: ,G i - % <6. c / �h ei_._ Phone No: y / 7'9. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PER / 4 4 ,,,E (20.)431-3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: r $T, REINSPECTIO EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: rnriFx k:.s,�x."..aU�s Project: . , • Type of Insp_ection: Address: ' ' / , -, 'i G•) 4'% GL !`lei` / y L Date Called: /- e- - „-- Special Instructions: Date Wanted: ....a.m. / - 7- p4 ;' ( p.m. Requester: '. ,L. - A'. ';2.rr-1 Phone ;/ f' _7V6P/ INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1 $47.00 REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Z Z fY W QQ 5 JU UO C o CO IA J r~ N LL W O u. Q = � Z • 1- O z I--. W W 0 O N 0 I— W H� W Z w U= 0 z .. ,., . :2 • t•;; • �.. . 'n 4�FL+� �rn "4r • t '.cr, ++.y�7�. Ciiy of Tukwila Fire Department Thomas P Keefe, Fire Chief Address . 7,•, 1 v TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM : :Project Name LCtW 0 ,S.c.S Q n (? /'('` Sp,..1 L 1 Retain .current i-nspection...schedule Needs shift inspection ( Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: t A Acs ��- Pre-Fire: Permits: be: F 1 44 c f Authorized Signature FINALAPP.FRM Rev. 2/19/98 Steven M. Mullet, Mayor Permit No. ` - `.' /- Date Suite # ? s T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 November 24, 2004 Mr. David Seely The Driftmier Architects 7983 Leary Way NE Redmond, WA 98052 Ciz of Tukwila Department of Community Development Steve Lancaster, Director RE: Letter of Incomplete Application # 1 Development Permit Application D04 -416 Law Offices of Cheryle Smith Harris — 320 Andover Park East Dear David: This letter is to inform you that your application received at the City of Tukwila Permit Center on November 19, 2004, is determined to be incomplete. Before your application can continue the plan review process the following items need to be addressed: Building Department: Ken Nelsen, at 206 431 -3677, if you have questions concerning the following: 1. Please provide a complete over all floor plan showing adjoining spaces and egress to corridor, etc. Please address the above comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 433 -7165. Stefania Spencer Permit Technician Enclosures File: Permit File No. D04 -416 Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431.3665 DEPARTMENTS: l !2 1O'4 Buildi4q 'vision Public Works Documents /routing sllp,doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D04 -416 DATE: 12 -02 -04 PROJECT NAME: LAW OFFICES OF CHERYLE SMITH HARRIS SITE ADDRESS: 320 ANDOVER PARK EAST Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision #afteribefore permit is issued Fire Preve Prevention Structural ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -07 -04 Complete [ Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RO TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01 -04 -0 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY t —1 -e l PI nk Division Permit Coordinator Not Applicable ❑ DATE: ACTIVITY NUMBER: D04 -416 DATE: 11 -19 -04 PROJECT NAME: LAW OFFICES OF CHERYLE SMITH HARRI SITE ADDRESS: 320 ANDOVER PK E, SUITE 103 1 Original Plan Submittal Response to Incomplete Letter # DEPARTM NTS: � � 4 7;3-194 / Building Division Public Works Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Response to Correction Letter # Documents /routing slIp.doc 2-28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Fire Prevention Incomplete {4. Planning Division EX. Revision # After Permit Issued Permit Coordinator DUE DATE: 11-23-04 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: //% ' LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: S' TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 12-21-04 Approved n Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: z i � ;I-z C4 w -IU O 0 U 0 J 1-- U) u_ w 0 g - d w zF l- 0 w ~ • w 0 O — o I— wW I I o ..z w U = 0 F- z 1 Date: r DEC_ C 4r City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. • Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Law Offices of Cheryle Smith Harris Project Address: 320 Andover Park East Plan Check/Permit Number: D04 -416 v1/4)E e a --5t)C3 I l (tiv(- 4 ea t WLtr r1 - Pt, is, 5 Steve: M. Mullet, Mayor Steve Lancaster, Director Contact Person: David Seely Phone Number: Summary of Revision: 6) Cc4 ' T e' e v `&- S H e fr 0. 0 Act) te lieu lt,0 IQ as— t —i -S; i t .i .7Q , -- ro eft T iNL RP .11 op ri n<wn .-s 2004 PERMIT CENTE Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: c� Entered in Permits Plus on 1 - \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Detach And Display Celificatc . . - . A - MPARTMENT -OF L B O R --A ND INDUSTRIES" • REGISTERED AS . 1:10bED1)3Y -LAW As • t iitil • •-• • rO/r4at•• • : - - KELLY' rt4mAt. -INC - 340:2 - -ST • N E grig 209.:. • • .AUBUR N WA: ;9 - Nasal And Display Catificase NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. rn CD 041 100 416 us —4 — 0 — ws 3 70 2C WASHINGTON CITIES INSURANCE AUTHORITY 320 ANDOVER PARK E., TUKWILA, WA 98188 SUITE 103 T. 1. - PERMIT SET COVER SHEET SITE PLAN S 6. II. 12. 13. 4. 15. 6. GENERAL NOTES IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BECOME FULLY AWARE OF ANY AND ALL CONDITIONS RELATED TO THE SITE AND EXISTING CONDITIONS THAT MAY AFFECT THE COST OR SCHEDULING OF GONSTRUGTION ACTIVITIES, PRIOR TO SUBMITTING A BID. PO NOT SCALE DRAWINGS OR DETAILS -- USE GIVEN DIMENSIONS. CHECK DETAILS FOR LOCATION OF ALL ITEMS NOT DIMENSIONED ON PLANS. DIMENSIONS ON PLANS ARE TO FACE OF EXISTING FINISHES, 6RIDLINE OR CENTERLINE U.N.O. NEW DOOR AND CASED OPENINGS WITHOUT DIMENSIONS ARE TO BE (45") FROM FACE OF ADJACENT WALL ON E HINGE SIDE OF DOOR THE DRAWINGS INDICA''E GENERAL AND TYPICAL DETAILS OF CONSTRUGT WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT RE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF NvSTRUGTION SHA -L BE USED, SUBJECT TO REVIEW AND APPROVAL ELY THE ARGHITEGT AND THE STRUCTURAL ENGINEER. BUI LD ING SYSTEMS AND COMPONENTS NOT SPECIFICALLY DETAILED SHALL BE INSTALLED, AS PER MINIMUM MANUFACTURERS RECOMMENDATIONS. NOTIFY THE ARCH ITEGT OF ANY RESULTING CONFLICTS. ALL WORK SHALL CONFORM TO APPLICABLE BUILDING CODES AND ORDINANCES. IN CASE OF ANY CONFLICT WHEREIN THE METHODS OR STANDARDS OF INSTALLATION OR THE MATERIALS SPECIFIED DO NOT EQUAL OR EX(...EED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAV S OR ORDINANCES SHALL GOVERN. NOTIFY THE ARCHITECT OF ALL CONFLICTS IMMEDIATELY. COORDINATE ALL OPERATIONS SUCH AS AREAS USED FOR MATERIAL STORAGE, ACCESS TO AND FROM WORK AND TIMING OF WORK WITH THE BUILDING OWNER AND PROPERTY MANAGER. THE BUILDING SHALL BE GGGUPIED DURING CONSTRUCTION. MAINTAIN EXITING FROM OCCUPIED AREAS. S. INSTALL DUST BARRIERS, BARRICADES, GUARDS AND OTHER PROTECTION AS REQUIRED TO PROTECT INSTALLED FINISHES AND FACILITIES, AS WELL AS OCCUPIED AREAS. PROVIDE TEMPORARY FILTERS OR CLOSE OFF RETURN AIR GRILLES DURING DUST AND ODOR PRODUCING ACTIVITIES. SOME ITEMS OR SYSTEMS INCLUDED IN THE CONSTRUCTION DOCUMENTS ARE TO BE "BIDDER DESIGNED" OR ARE PROVIDED BY OTHERS. THE ARCHITECT AND CONSULTING ENGINEERS WILL REVIEW ALL BIDDER DESIGN SUBMITTALS AND WILL DETERMINE IF THE SUBMITTAL 15 IN CONFORMANCE WITH THE GENERAL DESIGN CONCEPT. THIS REVIEW DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILIT`' TO CONFORM TO THE REQUIREMENTS OF ALL CODES AND THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL COORDINATE THE PLACEMENT OF BIDDER DESIGNED ITEMS WITH THE STRUCTURAL SYSTEM AND FRAMING. CONFLICT S SHALL BE BROUGHT TO THE ARCHITECTS ATTENTION PRIOR TO BID AND THE REOUIRED MODIFICATIONS INCLUDED IN THE BID PRICE. 1 0. CONCEPTUAL ELECTRICAL ANC HVAC INFORMATION IS INCLUDED WITH THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE INSTALLATION OF THEIR WORK. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS AND THE CONSULTING ENGINEERS) OR OTHER SUPPLEMENTARY DRAWINGS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION BY WRITTEN NOTIFICATION FOR CLARIFICATION. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS OWN EXPENSE AND AT NO EXPENSE TO THE OWNER OR ARCHITECT. THIS PROJECT CONTAINS GLAZING THAT WILL BE SUBJECT TO FEDERAL AND LOCAL GLAZING STANDARDS AND THE GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THESE REQUIREMENTS. IF THE GLAZING SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN COMPLIANCE WITH THE STANDARDS, HE /SHE SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. NO CLAIMS FOR EXTRAS FOR COMPLYING WITH THE STANDARDS WILL BE ENTERTAINED REGARDLESS OF THE CONTENT OF THE DRAWINGS AND SPECIFICATIONS. THERE SHALL BE NO EXPOSED PIPE, CONDUITS, DUCTS, VENTS, ETC. ALL SUCH LINES SHALL BE CONGEALED OR FURRED AND FINISHED, UNLESS NOTED AS EXPOSES' CONSTRICTION IN DRAWINGS. OFFSET STUDS WHERE REQUIRED 50 THAT FINISHED WALL SURFACES WILL BE FLUSH. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. ALL WOOD FRAMING DETAILS AND CONNECTIONS (SHOWN AND NOT SHOWN) SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE IBC. ALL LIGHT GAUGE METAL STUDS AND FRAMING SHALL BE INSTALLED PER THE STANDARDS AND DETAILS PUBLISHED BY THE STEEL STUD MANUFACTURER'S ASSOCIATION. FASTEN GYPSUM WALLBOARD TO ALL STUDS, TOP AND BOTTOM PLATES AND BLOCKING WITH TYPE S OR W DRYWALL SCREWS OR COOLER NAILS AT 1 INCHES O.G. MAXIMUM SPACING U.N.G. USE 5D NAILS OR *b X I SCREWS FOR 1/2" WALLBOARD AND 6D NAILS OR AS X I -1/4" SCREWS FOR 5/8" WALLBOARD. PROVIDE GALVANIC INSULATION BETWEEN DISSIMILAR METALS. 1. ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT USE OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFOR ALL EXIT SIGNS SHALL HAVE LETTERS SIX (6) INCHES HIGH MINIMUM, AND SHALL CONFORM WITH APPLICABLE CODES. REFER 1 DRAWINGS FOR EXIT SIGN LOCATIONS. THE GENERAL CONDITIONS OF THE CONTRACT AND TECHNICAL SPECIFICATIONS ARE CONTAINED IN THE PROJECT MANUAL. THE CONTRACTOR(S) AND 5L6- CONTRACTOR(S) ARE RESPONSIBLE FOR ALL ITEMS CONTAINED IN ALL OF THE CONTRACT DOCUMENTS. 20. NO MATERIALS FROM THE WORK ARE TO BE STOCK FILED ON PUBLIC RIGHT-OF-WAYS. ALL RUBBISH AND DEBRIS 15 TO BE REMOVED LOVED FROM THE SITE. 21. ADJACENT PROPERTIES, STREETS AND WALKS ARE TO BE PROTECTED FROM DAMAGE AT ALL TIMES. CONTRACTOR SHALL PROVIDE TEMPORARY FACILITIES AND EROSION CONTROL MEASURES TO PROTECT PUBLIC AND ADJACENT PROPERTY. 22. THE ARCHITECT ASS NO RESPONSIBILITY FOR ENGINEERING AND SURVEY DATA PROVIDED BY OTHERS. AGOt . AGOU5TK,AL AD. AREA DRAIN A.F.F. ABOVE FINISHED FLOOR AG6R. AGGREGATE ALUM. ALUMINUM ARCH. ARCHITECTURAL ASB. ASBESTOS ASPH. ASPHALT BD. BOARD BLDG. BUILDING BLK6. BLOCK ING BM. BEAM B.O. BOTTOM OF BOT. BOTTOM GB. CATCH BASIN CL&. CEILING CLK6. CAULKING CL. CLOSET GLR CLEAR G.M.U. CONCRETE MASONRY UNIT COL. COLUMN CONC. CONCRETE GONT. CONTINUOUS C.S. CRAWL SPACE DBL. DOUBLE DTL., DET. DETAIL DIA. DIAMETER DIM. DIMENSION DN DOWN DS. DOWNSPOUT DWG. DRAWING EA. EACH E.J. EXPANSION JOINT EL., ELEV. ELEVATION ELECT. ELECTRICAL EMER. EMERGENCY E.P ELECTRICAL PANELBOARD EQ. EQUAL EQPT. EQUIPMENT (E), E. EXISTING EXIST. EXISTING EXPO. EXPOSED EXT. EXTERIOR E.I.F.S. EXT. INSUL. FINISH SYSTEM FDN. FOUNDATION F.E. FIRE EXTINGUISHER F.E.G. FIRE EXTINGUISHER CABINET F .F. FINISH FLOOR FIN. FINISH FL. FLOOR FLASH. FLASHING FLUOR. FLUORESCENT F.O. FACE OF F.O.G. 'FACE OF CONCRETE F.O.F. FACE OF FINISH F I.O. FURNISHED BY OWNER AND INSTALLED BY OWNER F.O.S. FACE OF STUDS F.O.W. FACE OF WALL F . FIREPROOF F T. FIRE RETARDANT TREATED F.5. FLOOR SINK FT. FOOT OP FFFT FTC. FOOTING FURR. FURRING 6A. GAUGE GALV. GALVANIZED GL. GLASS G.L.B. GLIDE LAM BEAM G.S.B. '.''SUM SHEATHINGL BOARD GYPSUM WALL BOARD GYP. GYPSUM F :s EXISTING WALL DEMO WALL NEW WALL EXISTING GLAZING DEMO GLAZING NEW GLAZING-► 11ALL SECTION 4 * - - - ELEVATION MARKER 1 DETAIL TAIL /IINDOY4 TYPE MALL TYPE 0 ABBREVIATIONS PROJECT SCOPE DOOR 14J1.113ER H.B. HOSE BIB H.G. HOLLOW CORE HP V HARDhIOOD H.M. HOLLOW METAL HORIZ. HORIZONTAL HR. HOUR HGT., HT. HEIGHT H.W.H. HOT WATER HEATER INSUL. INSULATION INT.,INTER INTERIOR JAN. JANITOR LAM. LAMINATE MAX. MAXIMUM MECH. MECHANICAL MTL. METAL MFR. MANUFACTURER MH. MANHOLE MIN. MINIMUM MIR. MIRROR MISC. MISCELLANEOUS ('4), N. NEW N.I.G. NOT IN CONTRACT NC. OR * NUMBER N.T 5. NOT TO SCALE 0/ OVER O.G. ON CENTER O.H. OVER HEAD PERF. PERFORATED P.LAM. PLASTIC LAMINATE PLWD. PLYWOOD PR. PAIR P.T. PRESSURE TREATED PTO. PAINT P.T.D. PAPER TOWEL DISPENSER GUAM. QUANTITY R RISERS RAD. RADIUS RD. ROOF DRAIN REF. REFRIGERATOR REINF. REINFORCED, REINFORCING REQ. REQUIRED RM. ROOM R.O. ROUGH OPENING S.G. SOLID CORE SH. SHEET SHEATH SHEATHING SHLF. SHELF SIM. SIMILAR SPEC. SPECIFICATION SQ. SQUARE STD. STANDARD STL. STEEL STOR. STORAGE STRUCT. STRUCTURAL SUSP. SUSPENDED T. TREADS T.B. TOWEL BAR TEMP. TEMPERED T.S. TUBE STEEL T.P.H. TOILET PAPER HOLDER TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE V.B. VAPOR BARRIER W.C. WATER CLOSET HD. WOOD W/ WITH H/O WITHOUT HP. WATERPROOF OR WATERPROOFING WSCT. WAINSCOT THE CONTRACTOR MUST VISIT THE SITE PRIOR TO BIDDING AND DETERMINE THE FULL EXTENT OF THE WORK, EXISTING CONDITIONS AND BE RESPONSIBLE FOR SAME. 2 SCOPE OF WORK SHALL INCLUDE INSTALLATION OF NEW TENANT WALLS AND ALL INTERIOR FINISHES (TO INCLUDE FLOOR COVERING, BASE AND PAINTING). ELECTRICAL COMPONENTS AND HVAG 4 SPRINKLER SYSTEM ADJUSTMENTS SHALL BE BIDDER DESIGNED. CONTRACTOR TO MODIFY (E) FIRE SPRINKLER SYSTEM, (E) FIRE ALARM SYSTEM AND (E) HVAC SYSTEM TO MEET ALL CODE AND CITY REQUIREMENTS. 3. HVAC COMPONENTS HAVE BEEN INSTALLED UNDER A SEPARATE CONTRACT. CARE SHALL BE TAKEN TO PROTECT THE SYSTEM DURING CONSTRUCTION. MOD IF ICATI ONS TO HVAC COMPONENTS TO BE BIDDER DESIGNED. REVIEW EXISTING CONDITIONS PRIOR TO BIDDING. 4. HVAC WORK SHALL BE ACCOMPLISHED BY PUGET SOUND REFRIGERATION. CONTACT NEIL BAVINS PHONE: (2O6) 361 -2500. SYMBOLS DIRECTORY MATCH LIE GUT LINE DEMO DOOR IEIN DOOR euILDn+b SECTION ---- � - -'—� • Po.o. INTERIOR ELEVATION REVISION MARK CENTER LIE ti PARCEL NUMBER Phf feVkw approval Is subject to errors and of d. Approval Of corstruction documents doss not auku1111 the violation of any adopted nods a aninence. NNW of BLDG. SPRINKLERS: FIRE ALARM: oGGUPANCY LOAD SUITE 103 SPACE: EXITING SUITE 103: EXIT WIDTH = 1 X .2 = 2 IN READ. 34" PROVIDED. I EXIT REQUIRED BUILDING CODE DATA 2003 INTERNATIONAL BUILDING CODE BUSINESS GROUP B TYPE V -B FULLY 5PRINKLERED FIRE SPRINKLER MONITOR ALARM AS REQUIRED BY CITY OF TUKWILA 7 OCCUPANTS ( 112 5.F. / 100 = 1) ///////, E 1113 / /.//I VICINITY MAP DRAWING INDEX TOTAL AREA OF SITE: AREA OF EASEMENT: NET AREA OF SITE: LOT COVERAGE DATA: LOT COVERAGE BY BU I LD I NCB: TOTAL LANDSCAPE AREA : E'AVED I WALK AREAS: TOTAL TOTAL IMPERVIOUS SURFACE: NUMBER OF STORIES BUILDING HEIGHT LO PAL JURISDICTION CITY OF TUKWILA BUILDING DEPARTMENT 6200 SOUTHGENTER BLVD. TUKWILA, WA 8 8188 PH: (206) 433 -1800 FAX: (206) 433 -1833 AREA OF TENANT IMPROVEMENTS THAT PORTION OF LOT b OF ANDOVER INDUSTRIAL PARK NO. 3, ACCORDING TO PLAT RECORDED IN VOLUME l8 OF PLATS AT PAGE(S) 6 AND 1, IN KING COUNTY, WASHINGTON, LYING SOUTH OF A LINE WHICH I 185 FEET SOUTHERLY OF AND MEASURED PARALLEL TO THE NORTH LINE OF SAID LOT b. PROPERTY MANAGEMENT COMPANY J5H PROPERTIES, INC. I4g00 INTERURBAN AVE. S., SUITE 210 Seattle, WA G15168 -4654 PH: 206-244-2000 FAX: 206-614-46661 CONTACT: GFNJGK WIEGMAN • LAW OFFICES OF CHERYLE SMITH HARRIS aty of 11imile ING D PROJECT DATA 022320 -0060 13,144 SF 20,023 5F 54,121 5F 2 112 S.F. achnavadmik 16,581 S.F. = 23% 25,g 75 S.F . = 35% 31.211 S.F. = 42 13,161 S.F. = 100% 41,182 5.F. = 6595 28' -1 I/2' TO TOP OF PARAPET LEGAL DESCRIPTION PROJECT DIRECTORY ARMOUR UNSDERFER ENGINEERING LLC 13456 SE 21TH PLACE, SATE 200 REDMOND, WA 18052 PH - (425) 614 -0 Fax - (425) 614 -0850 CONTACT: BRIAN UNSDERFER TENANT IMPROVEMENT ° 0 ANDOVER PARK EAST, SUITE .103 faCINER WASHINGTON CITIES INSURANCE AUTHORITY P.O. BOX 1165 (MAILING ADDRESS) RENTON, WA 88051 CONTACT: JILL MAKELA QWNER'S PHYSICAL ADDRESS 320 ANDOVER PARK E #IOI TUKWILA, WA 4 18188 APPLICANT / ARCHITECT THE DR FTMIER ARCHITECTS, P.5. 7q83 LEARY WAY NE REDMOND, WA 48052 PH: (425) 881 -1506 FAX: (425) 881 -1306 CONTACT: DAVID SEELY EMAIL, davidOdrlf tm ier.Gom MECHANICAL ENGINEER: ABOSSEIN ENGINEERING 1844 114TH AVENUE NE BELLEVUE, WA 18005 PH - (425) 462 -4441 Fax - (425) 462 -1451 CONTACT: ALEXANDER ABBOSEIN • TUKWILA, WA 98188 PERMIT SET 1 AIM SITE PLAN ilL • i i i i 5D _1 Li Li I . F AO.O A2.0 A2.I Mallen No & Irma. shin bo mode to the sumps of work without prior approval ar Tukwila Building NOTE: Revisions will a Division. and may ! ude p plan submittal 111 id {and Dr Evans Black Dr Baer Btvd Walter Mall w ' gander :BMd TukwIla Pond ' I Corporate Dr NE S [2 Minkler ',� °'• Upla I'd Dr rn a r l Sax op Dr SHEET # DRAWING NAME : . AB o e i n g Longacr . ti4sIgacTes NaV Industrial 1 H r I ' ; ,Park f • ii. Sw 27th 1E- ca co O t�- a, it Triland Dr 6 : 4 5 N 180th St O r i l l a 0200? MPShill t,02 mL Ln. 42.0_03 Nav do n Tech no lackm 81Q4 COVER SHEET, SITE PLAN FLOOR PLAN, REFLECTED CEILING PLAN NOTES, DETAILS AND SCHEDULES • .e 6001! 1'800f1 INCOMP F.TE LTR#� The Driftmier Architects, Ps. 7983 Leary Way NE Redmond, WA 98052 (425) 881 -7506 mailOdriftmier.com REGISTERED ARCHITECT DAVID RANDALL SEED STATE OF WASHINGTON THIS DOCI Eb' ANTS A PROPRIETARY DESIGN A tD SY THE ARCHITECT AND SHALL NOT SE USED ON OTHER PROJECTS FOR ADDITIONS TO THIS PROJECT OR FOR COWLET ION OF THIS PROJECT SY OTHERS EXCEPT I'! PRIOR AGREEMENT IN NRIT!NG REVISIONS 04 DESCRIPTION onh I� PERM REV. IV80/04 RECSVED rnv (IP * POINT CONTD. ISSUE DATE: DRAWN BY: RNS CHECKED BY: ORS 3o NOVEMBER 2004 PROJECT NUMBER: I 20405.50 ; SHEET NUMBER: � AQO i • 4 REFLECTED CEILING PLAN WOMEN SUITE 103 - - - - -- - CONFERENCE(TRAINING ROOM SUITE 102 FLOOR PLAN INT. CEILING HEIGHT. PARTITION (INTERIOR TENANT SPACES) WALL TYPES SHIM GRID TO ALLOW GLG. TILE TO LAY PROPERLY IN GRID STRUCTURE BRACING PER AGOUST. INSULATION 0 GLG. IN OFFICES FIN. CEILING PER PLANS AGOUS. SEALANT ACOUS. INSULATION IN WALL EXTEND GVI3 TO CEILING 5/8" TYPE 'X' &NB BOTH SIDES DOOR DETAILS SHEET NUMBER: NOTES: 1 Pt I 416 I, •SS ISS S/ IS IS S 12. CEILING SYSTEM ATTACHMENT 15 PER DETAIL rte. - 1 �. BUILDING FjRijfFpF PLAN :I I 1\ 1 1I •' ■ C RELOCATED PI F I XTUZES FI 2. RECONFIGURE (E) CEILING TILE OR PROVIDE NEW AS NEEDED. REVISE SPRINKLER SYSTEM TO MEET ALL CODE 4 CITY REQUIREMENTS I:ELOGATED OFFICE 2 it-- __- it ----� 5. (E) CEILING 15 A.G.T. -I AT 9' -0" *. (E) CEILING TO BE MODIFIED AS REQUIRED TO REARRANGE (E) F -I CEILING LIGHT FIXTURES. 6. LIGHT FIXTURES SNAL. HAVE TIE WIRES PER CODE AND PER DETAIL 1. PROVIDE LIGHTS ON EMERGENCY CIRCUITS AS REQUIRED BY CODE OR LOCAL AUTHORITY. VERIFY LOCATIONS WITH ARCHITECT. 8. VERIFY LOCATION OF ALL HVAC DIFFUSERS I GRILLES W/ ARCHITECT PRIOR TO RECONFIGURATION 10. MODIFY FIRE SPRINKLER SYSTEM TO MEET CODE, NFPA 13 AND FIRE MARSHALL REQUIREMENTS. ALL NEW HEADS TO BE SEMI - RECESSED SPRINKLER HEADS. II. 6.C. TO MODIFY HVAC SUPPLY I RETURN DUCTS AND GRILLES AS REQUIRED TO RECONFIGURE SUPPLY AND RETURN GRILLES AS SHOWN.. SUBMIT PLANS TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. q. PROVIDE LIGHTING CONTROLS PER WA. STATE NREC. LOCAL SWITCHES ARE REQD. FOR ALL PRIVATE OFFICES. CENTRAL SWITCHING 15 ACCEPTABLE FOR OTHER AREAS. PROVIDE DUAL LEVEL SWITCHING FOR ALL MULTI -LAMP FLUORESCENT FIXTURES. PROVIDE SEPARATE CONTROLS FOR DAYLIGHT ZONES (PER WA STATE NREC.) OM OM I. A.K.A. CEILIN& 15 EXISTING. MODIFY CEILING GRID AS NEEDED FOR RELOCATED LIGHTS, NVAC AND SPRINKLER EQUIPMENT. 3. RELOCATE (E) FI LIGHT FIXTURES, SUPPLY AND RETURN GRILLES TO CONFIGURATION SHOT{ NOT ALL UNITS WILL NEED TO BE RELOCATED. VISIT 51TE TO CONFIRM EXTEND OF WORK PRIOR TO BIDDING. . 4 ..wa. ...a...•.r .. Jc.. r. -... ::.............. w... ......... ......... .+..+..b■•w. 0 (E) 5PR NKI.ER HEADS' 1 4 rri (N) 1- FI LIGHT FIXTURE LEGEND Fia EXISTING ESSE b - = = = �1 FLUORESCENT FI R FIXCETURE D RELOCATED (E) RECESSED FLUORESCENT FIXTURE (E) EXIT SIGN (N) CI RECESSED FIXTURE HVAC FIXTURE LEGEND 4 y • OP s u EXISTING 2' X 2' RETURN GRILLE 0 RELOCATED (E) 2' X 2' RETURN GRILLE EXISTING 2' X 2' SUPPLY DIFFUSER RELOCATED (E) 2' X 2' SUPPLY DIFFUSER ® (E) SPRINKLER HEADS • 0 (EJ UNFINISHED WALL (14) 4 NOTES: nronr. i OFFICE 1 (N) P 1. FOR WALL TYPES AND DETAILS SEE DETAIL \L- °(E) (E) UNFINISHED WALL (NJ WALLS II. OFFICE FURNITURE, SYSTEMS FURNITURE AND COMPUTER EQUIPMENT ARE F.O.1.0. OFFICE 2 2. FOR DOOR INFORMATION AND DOOR HARDWARE SEE DETAIL 3. REVISE/UPDATE (E) FIRE ALARM SYSTEM AS REQUIRED TO MEET ALL CODE AND CITY REQUIREMENTS. 4. PRIME AND PAINT ALL WALLS IN SUITE 103. PAINT TO BE P -I. 5. PAINT OR TOUGH UP PAINT ON ALL EXTERIOR WOOD WINDOWS WITH PAINT P -4. b. INSTALL B-I BASE ON ALL WALLS IN SUITE 103. 1. INSTALL CARPET C -4 ON ALL FLOORS IN SUITE 103. 8. FOR ADDITIONAL FINISH MATERIALS INFORMATION SEE FINISH SPECIFICATIONS /SCHEDULE q. USE EXISTING ELECTRICAL DUPLEX OUTLETS AND ADD ADDITIONAL DUPLEX OUTLETS AND PHONE/DATA OUTLETS (V) AS SHOWN. FOR PHONE/DATA OUTLET INFORMATION SEE DETAIL 10. FOR WALLS WITH ACOUSTICAL INSULATION: PROVIDE 3" MIN. ACOUSTICAL MINERAL INSULATION UP WALLS TO STRUCTURE OR ACROSS CLG. OF SPACES TO BE 150 ATED. PROVIDE COMPLETE ACOUSTICAL SEPARATION 4 SEAL ALL JOINTS. SEE DETAIL 12. PROVIDE FIRE EXTINGUISHERS AND CABINETS AS REQUIRED BY FIRE MARSHAL. COORDINATE LOCATIONS WITH AND RECEIVE APPROVAL FROM ARCHITECT PRIOR TO INSTALLATION. MAINTAIN EXISTING EQUIPMENT OR SALVAGED UNITS AS AVAILABLE. HORN/STROM FIRM- ALARM (to (N) ION b' -4" 0 ELECTRICAL LEGEND EXISTING LIGHT SWITCH NEW LIGHT SWITCH REVIEWED FOR CODE COM PL.ZANCE DEC 13 2004 C,Ity Of Tukwila WADING DIVISION 3 HINGE MCKINNEY MFG. I PASSAGE YALE SECURITY INC. I STOP TRIMGO/BBW EXISTING IDOOR I RELI&HT I EXISTING DUPLEX OUTLET NEW DUPLEX OUTLET EXISTING PHONE/DATA OUTLET NEW PHONE/DATA OUTLET 3' - 0" FIELD VERIFY O SOLID CORE WOOD DOOR NOTES: I. &LAZING TO HE TEMPERED SINGLE PANE. 2. FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION. 3. 3' - WIDE X 1'-O' HIGH X I -3/4" THICK SOLID CORE DOOR WITH RED OAK VENEER FACE 4. DOORS AND FRAMES TO BE STAINED AND FINISHED TO MATCH WOOD FINISH AT SUITE ENTRY. 5. LATCH SET TO BE LEVER TYPE. INSTALL BARRIER FREE CLOSURE 6. CASED DOOR FRAME t TRIM TO BE 1. HARDWARE GROUPS IPI 14 - TENANT SPACE OFFICE DOORS 4. FOR DONOR HEAD, 4 t THRESHOLD SEE DETAIL TA21144.5x45 PB5 4OILN 1210WVGP V U526D U526F U532D 8. HARDWARE 15 AVAILABLE THROUGH KRAUSE t SC EELAR. CONTACT ROSS HENNE, PHONE: (425) 883 -1243. The Driftrnier Architects, i S. 7983 Leary Tay NE Redmond, WA 98052 (425) 881 -7506 mail @driftmier.com FLOOR PLAN REFLECTED CEILING PLAN ISSUE DAT 6388 t•.? KtGIST ERED ARCHITECT r- �K") - DAVID RANDALL SEELY STATE OF WASHINGTON THIS OOdAIEN REPRESENTS A PROPRIETARY DESIGN OIINEC BY THE ARCHI AND SMALL NOT BE USED ON OTHER PROJECTS FOR AOO:TIONS TO THIS PROJECT OR FOR COMPLETION OF THIS PROJECT BY OTHERS EXCEPT BY PRIOR AGREEMENT IN NRIT REVISIONS NO. DESCRIPTION I DATE ZI\ PERMIT REV. II/5O /O4 NrCIFETPVED a POUR Cerr 30 NOVEMBER 2004 DRAWN BY: RNS. DRS CHECKED BY: DRS PROJECT NUMBER: 20405.50 FINISH SPECIFICATIONS & SCHEDULE MARK ITYPE 1LOCATION [MANUFACTURER JPROI7UCT j PAINT FINISHES P -1 • PAINT FINISH ALL WALLS SHERWIN WILLIAMS SATIN FINISH 1ARCHITECT SEMI -GLOSS TO BE SELECTED BY P -4 PAINT FINISH WINDOWS SHERWIN WILLIAMS TO BE SELECTED BY ARCHITECT VPA2G29PR23212050 120 (2) 52W T8 GENERAL 2 -LAMP PARAOOLIC Cl TRIM & WOODWORK FINISHES DOOR LIGNTOLIER 715213U/3037CLW , 120 (3) 32W TRIPLE TUBE I WD -1 • WOOD STAIN & VARNISH SYSTEM MILLWORK, DOORS & CASEWORK 1 MATCH ARCHITECT'S SAMPLE SATIN FINISH FLOOR COVERINGS C -4 CARPET ALL FLOORS SHAW STANDOUT TO BE SELECTED BY ARCHITECT CEILING MATERIALS AC1-1 LAY -IN ACOUSTICAL TILE IN GRID ALL CEILINGS USG INTERIORS, INC. ECLILPSE CLIMA PLUS ILLUSION TWO /24 ( #78785) WITH DONN DX GRID — EASE MATERIALS 5 -1 RUBBER OR VINYL BASE ALL WALLS ROPPE 4" HIGH , COVED T O E S E L E C T E P Y ARCHITECT 1 WASHINGTON CITIES INSURANCE AUTHORITY 320 ANDOVER PARK E., TUKWILA, WA 98188 SUITE 103 T. I. - PERMIT SET NOTES DETAILS SCHEDULES LIGHT FIXTURE SCHEDULE Type Location S Type ! Me nut. i Catalogue Number V. Il amp Notes F1 OFFICES (EXIST. FIXTURES) LIONTOLIER I VPA2G29PR23212050 120 (2) 52W T8 GENERAL 2 -LAMP PARAOOLIC Cl CLOSET LIGNTOLIER 715213U/3037CLW , 120 (3) 32W TRIPLE TUBE , COMPACT FLOUR. POWNLIGHT IN ACT I 1 ii DQOR HEAD. C , DOOR SILL OAK VENEER DOOR FINISHED FLOOR (TRANSITION UNDER DOOR) c� WOOD DOOR DETAILS T3, POOR JAMB NOTES: I. CONDITION SHOWN IS A TYPICAL FRAMED WALL. 2 DOOR JAMBS TO BE FINISHED WITH STAIN I CLEAR FINISH. SCALE: 3'=ILO" /\ f L I S'HT FIXTURE ANGER WIRES (SEE CEILING NOTES) L 16HT FIXTURE t'L anal m,i III l lIIH liuWlnllunUil, 111 GYPSUM BOARD CEILING OR ACOUSTICAL CEILING WHERE OCCURS FLUSH - MOUNTED SPOT LIGHT (51 M.) III NOM MiliMe 'Iilllljll l.l .:I1 4 'I IaIIIIIrmII III HANGER WIRES ATTACHED TO FIXTURE $ ANCHORED TO STRUCTURE GYPSUM BOARD CEILING OR ACOUSTICAL CEILING, WHERE OCCURS LIGHT FIXTURE fr42j1 LIGHT TIE DETAIL FINISH SPECIFICATIONS /SCHEDULE LIGHT FIXTURE SCHEDULE SCALE: V3 1-1/2' = Ira 1 SCAB: I-I/' = I'-0' 1 SCAM V I. PROVIDE 12 OA. (MIN) HANGER WIRES • 4' -O' 04. ALONG MAIN RUNNERS. 2. PROVIDE 12 oA. HANGER WIRES AT THE ENDS OF ALL MAIN AND GROSS RUNNERS WITHIN 8" FROM THE SUPPORT AT THE PERIMETER OF THE CEILING AREA. WIRES SHALL NOT HANG MORE THAN I IN 8 OUT OF PLUMB. 3. WIRES SHALL NOT ATTACH TO OR BEND AROUND INTERFERING MATERIALS OR EQUIPMENT. PROVIDE TRAPEZE OR OTHERS SUPPLEMENTARY SUPPORT MEMBERS AT OBSTRUCTIONS TO MAIN HANGER SPACING. PROVIDE ADDITIONAL HANGERS, STRUTS OR BRACES AS REQUIRED AT ALL CEILING BREAKS, SOFFITS OR DISCONTINUOUS AREAS. 4. CEILING GRID MEMBERS MAY BE ATTACHED TO NOT MORE THAN 2 ADJACENT WALLS. CEILING GRID MEMBERS SHOULD BE AT LEAST 1/4" FREE OF OTHER WALLS. 5. AT THE PERIMETER OF THE CEILING AREA, WHERE MAIN OR CROSS RUNNERS ARE NOT CONNECTED TO THE ADJACENT WALL, PROVIDE INTERCONNECTIONS BETWEEN THE RUNNERS AT THE FREE END TO PREVENT LATERAL SPREADING. WHERE THE PERPENDICULAR DISTANCE FROM THE WALL TO THE FIRST PARALLEL RUNNER 15 12" OR LESS, THIS INTERLOCK IS NOT REQUIRED. b. PROVIDE SETS OF FOUR 12 &A. SPLAYED BRACING WIRES ORIENTED 4 10 DEGREES FROM EACH OTHER AT 8 FEET BY 12 FEET ON CENTER. PROVIDE BRACING WIRES AT LOCATIONS NOT MORE THAN I/2 THE SPACING FROM EACH PERIMETER. THE SLOPE OF THESE WIRES SHALL NOT EXCEED 45 DEGREES FROM THE PLANE OF THE CEILING AND SHOULD BE INSTALLED IN SUCH A MANNER THAT THE DIRECTION OF THE WIRE ALIGNS AS CLOSELY AS POSSIBLE WITH THE DIRECTION OF THE FORCES ACTING ON THE WIRE. 10. SEPARATE ALL CEILING HANGING AND BRACING WIRES AT LEAST 6 INCHES FROM ALL UNBRACED DUCTS, PIPES, CONDUIT, ETC. FLUSH OR RECESSED CEILING LIGHT FIXTURES OR AIR TERMINALS OR SERVICES WEIGHING LESS THAN 56 POUNDS MAY BE SUPPORTED DIRECTLY ON THE RUNNERS OF A HEAVY DUTY SYSTEM BUT, IN ADDITION, THEY MUST HAVE A MINIMUM OF TWO 12 GA. SLACK SAFETY WIRES ATTACHED TO THE FIXTURE AT DIAGONAL CORNERS AND ANCHORED TO THE STRUCTURE ABOVE. ALL FLUSH OR RECESSED CEILING LIGHT FIXTURES OR AIR TERMINALS OR SERVICES WEIGHING MORE THAN 56 POUNDS SHALL BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN 4 TAUT 12 GA. WIRES EACH ATTACHED TO THE FIXTURE AND TO THE STRUCTURE ABOVE REGARDLESS OF THE TYPE OF CEILING GRID SYSTEM USED. THE WIRES AND THEIR ATTACHMENTS MUST BE CAPABLE OF SUPPORTING 4 TIMES THE WEIGHT OF THE UNIT. SUPPORT SURFACE- MOUNTED LIGHT FIXTURES BY AT LEAST TWO POSITIVE DEVICES WHICH SURROUND THE CEILING RUNNER AND WHICH ARE EACH SUPPORTED FROM THE STRUCTURE BY A 12 GA. WIRE. SPRING CLIPS OR CLAMPS THAT CONNECT ONLY TO THE RUNNER ARE NOT ACCEPTABLE. PROVIDE ADDITIONAL SUPPORTS WHEN LIGHT FIXTURES ARE 8 FEET OR LONGER. SUSPENDED CEILING NOTES SCALE: MIte 2 AGOUS. SEALANT (EA. SIDE) PREFINISH MEDIUM BRONZE TO MATCH STOREFRONT. • MI MTL. TRIM GAP 5 " 5/8' 3 5/8 " 5/8" (E) WINDOW JAMB (E) GLAZING 1... 1 4 1 -----___ WD BLOCK ( PAINT TO MATCH WINDOW) '11 STEEL STUD FRAmING ACOUS. INSULATION IN WALL 5/8" GWB 4 WALL /WINDOW CONNECTION SCALE: 1-1/2' = 3/4 W.M. -B OAK I/8" R/ EASED EDGES WHERE EXPOSED NEW FRAMED WALL 5/5 "043, TYP. BOTH SIDES INTERIOR WINDOW SCALE: 3' = I AGOUS. SEALANT BOTH SIPES. SHIM WINDOW STOP GLAZING OAK JAMB KITH W.M.-5 TRIM TRIM, TYP. (SEE DETAIL ABOVE) WINDOW JAMB CEILING STRUCTURE CEILING (I) SPARE PORTS (UTURE USE) CODE COMPLIANt.t DEC 13 2004 STRUCTURE qty Of Tu kwila BUILDING DWISION NEW 5'-O" WIDE X 4' -0' HIGH OAK FRAMED RELIGHT. WD -I FINISH. SE DETAIL 4 /A2.1. PARTITION BRACING TELEPHONE/NETHORK WALLPLATE (TYP) I) ALL TELEPHONE GABLE TO BE CATEGORY 5E. ALL 21 NETWORK GABLE TO BE CATEGORY 5E OR BETTER. ATTACH TO STRUGT. W/ POWER DRIVEN OR EXPANSION TYPE ANCHORS TWO 12 GA. WIRES • 8' O.G. OR TO RESIST 5 PSF TRANSVERSE LOAD. ATTACH WITH HAND WRAPPED TIGHT LOOPS. ATTACH TO MAIN RUNNER OR 'PERPENDICULAR TO PARTITION MAX PARTITION HT - 10 MAX PARTITION WT - 15 LBS PSF ATTACH TO STRUCTURE AND TO PARTITION 1^1/TWO #8 SCREWS. ONE RIGID BRACE ® 8' O.G. OR TO RESIST 5 PSF TRANSVERSE LOAD. ALTERNATE SIDES. • BRACES SHALL BE DOUBLE BACK TO BACK OR NESTED AS REQUIRED FOR PLENUM HEIGHT TO 10'. BRACES NOT REQUIRED WITHIN 8' OF INTERSECTING PARTITIONS. MATERIAL FOR PLENUM HEIGHT UP TO 5' -O ": I -I/2" X 16 GA. GOLD ROLLED CHANNEL OR 1/8" HAT CHANNEL OR I -5/8" X 25 GA. OR GREATER C STUD. (I) TELEPHONE JACKS AND 4 -PAIR GAT. 5E GABLE OR BETTER (I) NETWORK/DATA JACKS AND 4 -PAIR GAT. 5E OR BETTER GANG MUDRING/PLATE (TYP) 3) CONTRACTOR TO PROVIDE A SINGLE MUDRING VV/ PULL STRING AT EACH LOCATION FOR TELE/DATA CONTRACTOR. STUB CONDUIT DOWN INTO GRAWLSPAGE. ALL NON - ACCESSIBLE AREAS TO BE IN CONDUIT. PHONE /DATA ,WALL PLATE 12' -10 I /2't 5'-O' P -I ON (N) 61113. RECEPTION - WEST WALL SCALE: 1/4" = I' ►is: I 1' a I'-0' ` AN2J2 044•1--E-Atif RECEPTION WALL W/ WINDOW I AM} Ir 6 \ The Driftmier Arch�t S 7983 Leary Way N Redmond, AA 9805 (425) 881 -7506 mail @driftmier.com 6388 REGISTERED ARCHITECT • DAVID RANDALL S Y STATE OF WASHINGTON THIS MOMENT REPRESENTS A PROPRIETARY DESIGN aINED BY THE ARCHITECT ANC SHALL NOT BE USED ON OTHER PROJECTS FOR ADDITIONS TO THIS PROJECT OR FOR COMPLETION OF THIS PROJECT BY OTHERS EXCEPT BY PRIOR AGREEMENT IN WAITING REVISIONS RECSVIED rnv mow awaTE ISSUE DATE: 16 NOVEMBER 2004 DRAWN BY: RNS C. NECKED BY: ORS PROJECT NUMBER: 20405.60 SHEET NUMBER: I A2.1 • 4 fr ntM. rNM• .•. ww.. • • 4