Loading...
HomeMy WebLinkAboutPermit D04-458 - GIERE RESIDENCE - GARAGEGIERE RESIDENCE/GARAGE 4408 S 124 ST D04 -458 • • • Parcel No.: 0179000555 Address: 4408 S 124 ST TUKW Suite No: City a. Tukwila Tenant: Name: GIERE RESIDENCE Address: 4408 S 124 ST, TUKWILA WA Owner: Name: GIERE PETE Address: 4408 S 124 ST, TUKWILA WA Contact Person: Name: PETE GIERE Address: 4408 S 124 ST, TUKWILA WA Contractor: Name: OWNER AFFIDAVIT IN FILE Address: 4408 S 124 ST, TUKWILA WA Contractor License No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us DEVELOPMENT PERMIT Expiration Date: DESCRIPTION OF WORK: CONSTRUCTION OF A NEW 28 X 24 SQ FT TWO -STORY GARAGE WITH STORAGE. Phone: 206 343 -3753 Phone: 206 343 -3753 Phone: 206 343 -3753 Steven M. Mullet, Mayor• Steve Lancaster, Director Permit Number: D04 -458 Issue Date: 06/24/2005 Permit Expires On: 12/21/2005 Value of Construction: $34,857.68 Fees Collected: $1,011.30 Type of Fire Protection: N/A International Building Code Edition: 2003 Type of Construction: VB Occupancy per IBC: 26 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Storm Drainage: N Street Use: N Profit: N Water Main Extension: N Private: N Water Meter: doc: IBC - Permit D04 -458 Public: Non - Profit: N Public: Printed: 06 -24 -2005 doc: IBC - Permit City o: Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Permit Center Authorized Signature: D04 -458 Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: D04 -458 Issue Date: 06/24/2005 Permit Expires On: 12/21/2005 Date: 6% 25 # 93.* " I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Signature:_ Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 06 -24 -2005 ::i�: a;:. Parcel No.: 0179000555 Address: 4408 S 124 ST TUKW Suite No: Tenant: GIERE RESIDENCE doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS * *continued on next page ** D04 -458 Permit Number: D04-458 Status: ISSUED Applied Date: 12/23/2004 Issue Date: 06/24/2005 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Truss shop drawings shall be provided with the shipment of trusses delivered to the job site. Truss shop drawings shall bear the seal and signature of a Washington State Professional Engineer. Shop drawings shall be maintained on the site and available to the building inspector for inspection purposes. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 7: All wood to remain in placed concrete shall be treated wood. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 10: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. Printed: 06 -24 -2005 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or regulating construction or the performance of work. Signature: Print Name: ' c 11,6 t' _- doc: Conditions D04 -458 as outlined. All provisions of law and ordinances cancel the provision of any other work or local laws Date: �'"' / Printed: 06 -24 -2005 Site Address: - I L iOS 5, 12 ti 4A. s+ 'rvkw; Iv, Suite Number: 1 e Property Owners Name: r C fe & Tenant Name: Mailing Address: SC.M C CONTACT PERSON Name: Mailing Address: Zip E -Mail Address: r54JCD 1.1r a i) • Co p GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page) Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: E -Mail Address: Company Name: Mailing Address: CITY OF TUKWILA, Community Development A partment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 S Ah C \permits plus \icc changes \permit application (7 -2004) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** /i <L Ce.�5/,'J1L�:C.41 J Ze t/ / .1 ' 4 5 ? ,Viq Contractor Registration Number: t114L 4 /Z ( 7 "2/�� Expiration Date: I / Z — z <, * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record r/gt,'i. l / ! 4‘..4 , / r 4.4.,,e e 7 e. 4.4 City Contact Person: Day Telephone: 444 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Contact Person: E -Mail Address: Page l Building Perri 1o. Mechanical Permit No. Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: (//7P!/t ��YS City C ,,4.:1 City Day Telephone: Fax Number: New Tenant: ❑ .... Yes ❑ ..No Day Telephone: 26C. - 39 3 -3 City Fax Number: State State State Floor: /,14 Yg..37c State Zip n Cc L State Fax Number: (303) 74/ -73 f F Zip gofz/ Zip Zip City Day Telephone: Fax Number: BUILDING PERMIT INFORMATION - 206 -431 -3670 n lion of Project (contractor's bid price). $ :.-70 i e) Existing Bu ing Valuation: $ �4Valua ( p Scope of Work (please provide detailed information): , :t• c u.0.0.. le toy.^ ,1e - e k ' Ae r e r 64.'Q e A /e,i /a he._ / 1 4 c e cl eAl AJ C ea" ^.+ e1A to c`"' Will there be new rack storage? ❑ ..Yes ❑ .. No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑.. Sprinklers ❑ ..Automatic Fire Alarm None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ .. No If "yes", attach list of materials and storage locations on a separate 8 -1/2 .x 11 paper indicating quantities and Material Safety Data Sheets. \permits plus\icc changes \permit application (7.2004) Page 2 Handicap: Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I't Floor 2n Floor 3r Floor Floors thru Basement Accessory Structure* • Attached Garage Detached Garage 6 y z S .' i Woeri J 'F�'t'y'lr Attached Carport fit% up Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION - 206 -431 -3670 n lion of Project (contractor's bid price). $ :.-70 i e) Existing Bu ing Valuation: $ �4Valua ( p Scope of Work (please provide detailed information): , :t• c u.0.0.. le toy.^ ,1e - e k ' Ae r e r 64.'Q e A /e,i /a he._ / 1 4 c e cl eAl AJ C ea" ^.+ e1A to c`"' Will there be new rack storage? ❑ ..Yes ❑ .. No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑.. Sprinklers ❑ ..Automatic Fire Alarm None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ .. No If "yes", attach list of materials and storage locations on a separate 8 -1/2 .x 11 paper indicating quantities and Material Safety Data Sheets. \permits plus\icc changes \permit application (7.2004) Page 2 Handicap: PUBLIC WORKS PERMIT. INFORMATION — 206- 433 -0179 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila 0... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila 0... VatVue ❑ .. Renton ❑ ...Seattle ❑ ...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut cubic yards ❑ .. Work in Flood Zone ❑ ...Total Fill cubic yards ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑...Water Only Meter Size ❑...Sewer Main Extension Public _ ❑ ...Water Main Extension Public _ FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ... Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: Number of Public Fire Hydrant(s) 0... Sewage Treatment Day Telephone: City State Zip Day Telephone: City State Zip %permits plus\icc changes ■permit application (7.2004) Please refer to Public Works Bulletin #1 for fees and estimate sheet. If „ „ ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line If Call before you Dig: 1- 800 - 424 -5555 „ WO# WO# WO# Private Private ❑ .. Highline ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ .. Maintenance Agreement(s) ❑...Hold Harmless ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance Page 3 ❑ ...Renton ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑...Deduct Water Meter Size Unit Type: Qty Unit Type: Qty . Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Uni 10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator oler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilatio an Connected to Sing uct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Vent' ation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent ood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment C MECHANICAL PERMIT INFO7"" — 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: Day Tele • one: E -Mail Address: Fax Nu • er: Contractor Registration Number: Expir. ion Date: * *An original or notarized copy of current Washington State Contractor License m .t be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New ....❑ Replacement ❑ Commercial: New .... ❑ Replacement City State Zip Fuel Type: Electric ❑ Gas ....D Other: Indicate type of mechanical work being installed and the • uantity below: PERMIT APPLICATION NOTES.- Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT ORIZED AGENT: Signature: � j -� Date: Dec.- I g 61 Print Name: 64-e- Grt e-fe Mailing Address: 44 C'$ S. 12 9 k4 $+ \permits plus \icc changes \permit application (7.2004) Page 4 Day Telephone: 20G - 3 3 1S3 City (nr q State 4 715/ �a Zip Date Application Accepted: 1.2 a 3 d `f Date Application Expires: Staff Initials: 1 Receipt No.: R05 -00926 Initials: SKS User ID: 1165 Payee: PETE GIERE ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 0179000555 Permit Number: D04 -458 Address: 4408 S 124 ST TUKW Status: APPROVED Suite No: Applied Date: 12/23/2004 Applicant: GIERE RESIDENCE Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Check 2405 611.30 BUILDING - RES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 Account Code Current Pmts Payment Amount: 611.30 Payment Date: 06/24/2005 04:40 PM Balance: $0.00 i�_ 9 ; )7/01 606.80 4.50 Total: 611.30 i(iiA_.. 611_ (.) Printed: 06 -24 -2005 4 4.w Y - aA'.1-.4.1, L...• 44 (- •:i•.'44 - 1114. Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 0179000555 4408 S 124 ST TUKW GIERE RESIDENCE R04-01719 SKS 1165 PETE GIERE TRANSACTION LIST: Type Method Payment Cash BUILDING - RES PLAN CHECK - RES Description RECEIPT Account Code 000/322.100 000/345.830 Permit Number: Status: Applied Date: Issue Date: Payment Amount: 400.00 Payment Date: 12/23/2004 02:20 PM Balance: $611.30 Amount 400.00 Current Pmts 3.38 396.62 Total: 400.00 D04-458 PENDING 12/23/2004 ;7;0 'VITAL 400 , .;•.V• Printed: 12-23-2004 ' , „ ' a — • — Project:. G / E r e i i S Type of Inspection: i /AM4.- U Address: 4/YO& $ / Date Called: Special Instructions: Date Wanted: /1 6 — O C- ( p.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: C I) /"" .41.14/ /71110- P/ rat -1. 2 ,4>'- 113 ctor:. Date: / , /)- 1A''w4 X. A c...�/r //7 //J f 1 ' 04 8.00 REINSPECTION F E REQUIRED. Prio to inspection, fee must be paid at 6300 Southcente Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: trig'#'.; Approved per applicable codes. Corrections required prior to approval. Date: Project: �1 Type of Inspection: /7l4:, �; ;) , Q Address 1/yie, c, l N Date Called: Special Instructions: CI, �.• /� OY'1 eia Date Wanted: : - 7 e. ..5 a.m. Requester: Phone No: ID Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMI ( 06)431 -36 1 4 COMMENTS: .4/,-,7/7/e,"/ • eceipt No.: Date: — 06 58.00 REINSPECTION FEE REQUIRES .. Prior to inspection, fee must be aid at 6300 Southcent r Blvd., Suit 100. Call to sechedule reinspection. Date: Corrections required prior to approval. N' M•;1►,Ir.,.4;'. u i° ti,44+!4 !■ •'�t�4. �1i3rjit4" F+. •r'#'•++irrt� 11 "*.'tbo k:4):' Project: Type of Inspection: Address: Date Called: Special Instructions: L71-10 Date Wanted: 3 -2 a.m. --cn c Requester: Phone No: } , lS •l uir INSPECTION RECORD Retain a copy with permit INSPEC • N NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 Approved per applicable codes. L2* �s& 14 Corrections required prior to approval. COMMENTS: C f�C.t e r° 2 -) Bo r. ,'U ?'Z AS h (_, g-z 5 4,, r� L Date: 2�_ L1 $58.00 REINSPECTI N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: COMMENTS: /o f 7-7 e As ir./ ----Ma l Address: t 00 Date Called: Special Instructions: /,/!/G! / • e f 1 7 / Phone No: ,? ∎(..4 - /.liJ -f . /--", S 4.40.`fi.•i!..e_ / 2 7.6 -1/! ///Tl f' "-l--1 il,, .- ',Y9'1 --2- e Uri' ../ /..,, // /1 , fr2Ge,.,, P _ h/_- 4) (e g,r2 71 ,z C . � , / / 3/1- )t 7g — . / - 2 4 2 £ :2 sZe !/wt Le 4 An---01A-7 4,. 6-7-7 o��.e. Project: ', Type of Inspection: /'yie." /74-r) Address: t 00 Date Called: Special Instructions: Date Wanted: �/�yy —Z3- m, p.m Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit • MilaIMMINVISNIMMEEMIMOMEN •"44 Corrections required prior to approval. Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Date: • Pr Ul —(r/ /, / / ////���jjj /( \��// /�[ � •1/ 1 451,1( Type of Ins etio [/ �/(J �Addelsti Ot q s , 12 Lt st , Date Called: Special Instructions: � �( L (�i� i ;.l \le6th la) ,Q1 i)ic--trical . Date Wanted: � ( 1 (� rn. l�-� .m. Requeste��„ j, • t ., P h n No, INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Approv ei -• per a plie bie code ■ required prior to approval. INSPECTION RECORD Retain a copy with permit COMMENTS: 7 � Ifrz, C -, 116 ee r49 El $58.00 REINSPECTION I EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: COMMENTS: . � Type of Inspection: -- r k 4 A ress: -Sel? i (2 I) 6-re s , --.-e. . 6 (.... ez-o--7 ...--Z .ii a Date Wanted: I ( am � ( �-`. t� �p . .m . . !! �' Requester: ` Pho rC 7LQ a No: ( Q °Z.14 -- 2 7 �, 2-) L / t,49/ . / o ^-�, ,c i7 S 1`v, �r ! j 3 ) - 7 7 - - ; / / 4)4? e /e., -. _ , -.,_.-2 ".r A,/, (fro S - 4' /, T --- ye 1/44 - 2-447 6.; e. 7, zW 7 _ v P o)ect: -��� PAP ,fir r .n- . � Type of Inspection: -- r k 4 A ress: -Sel? i (2 _st-, Date Called: (2 ( I o s- _ Spe ial Instructions: Date Wanted: I ( am � ( �-`. t� �p . .m . . !! �' Requester: ` Pho rC 7LQ a No: ( Q °Z.14 -- 2 7 �, Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECT ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 • SL PE IT N 06)431 -3670 Corrections required prior to approval. rr Date: El $58.00 REINSPECTION FL REQUIRED. Prior to inspection,'fee must be paid at 6300.Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: • August 1, 2005 City of Tukwila Attn: Building Official Dear Sir: Bruce S. MacVeigh, P.E. Civil Engineer /Small Site Geotechnical 14245 59 Ave. S. Tukwila, WA 98168 Z Office: (206) 242 -7665 Fax: Same z mo w. U 0 U w= J I.- CO u w 0 u- = • a Ili ? � Z 0 , w DO U O - w w . • U w O ~' Subject: Alternate J -Bolt Washers, One Story Garage for Pete Giere, Tukwila, WA Inadvertantly 2 inch square washers were used to fasten the walls to the concrete embedded J -bolts for the new garage. It is understood that the current code requires 3 inch square washers. In this situation the 2 inch square washers are acceptable. The reason is the relatively small size of the structure, its light weight (in a seismic event), and the fact that it is only one story, limiting is sail area due to wind loading. In addition, its location is surrounded by existing buildings, thus limiting its wind exposure factor. Questions relating to the above may be made directly to this office. Bruce S. MacVeigh, P.E. Civil Engineer Giere01 0541 EXPIRES: 4/24/ Q 7 / �' � ''c)f z Piro 4ct; A /sr: - 7 2 Type of InspIcticere-Sg L' M Av. ./tri Aaare S'. L4 Date Called: . . Special Instructions: Date Wantea: 7f Requester/ / . k&A P one o: . 20(.9 A INSPECTI O. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION Po -- (pg PE• I 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 (206)431-3670 COMMENTS: • • . Date:7_, L7 - 4 „ Approved per applicable codes. 'Corrections required prior to approval. El $58.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be 1---1 paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: Date: L . Pr je : ) re If es • Type of Inspection: i -I ( - (, AddrAssI ( 2(4 .5._LDate i Calle : .....,, - I (.;, SpQl IrAtrictions: Date Wanted: A:z) Requester: Fr92e4od _..... INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 )6)d PE (2 06)431 -3670 CO MENTS: Approved per applicable codes. Corrections required prior to approval. 1 $58.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Pr l9ct:∎ Typ of Ins coon: Address 0 s , i 24 .,...s.f... 44 Date Called. Spe is Instructions: Date Wanted: 7 � 7 � � ' Requester: e-- Phone No: -3S INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 206 431 -3670 Corrections required prior to approval. COMMENTS: Approved per applicable codes. ri $58.013 EINSPECTION I'± E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: J i4 . Tp f Iseto: : N e,-7 I drs: , J,1,e Cle: 6 - .2 O' pca ntutos ae Wne: p .. r rt. /4e-A ' , .( bia6 " euse:- ' N: Poe tr ')." * * • 14..... : -■ I ,,( - .2f Project., . . Approved per applicable codes. COMMENTS: - Cor . )-11lA ( - Fow c‘OcL 0.1 41/ (-) Inspector: A Corrections required prior to approva E $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: V ; • Prepared by: Bruce S. MacVeigh, P.E. 14245 59th Avenue S. Tukwila, WA 98168 (206) 242 -7665 STRUCTURAL CALCULATIONS FILE COPY Perm 1 " - New One Story Garage 4408 S. 124th Street Tukwila, WA Tax ID #: 017900 -0555 Client: Pete Giere 4408 S. 124th Street Tukwila, WA 98178 (206) 234 -2481 CORRECTION LTR# REVIEWED FOR CODE COMPLIANCE Annormpo JUN 2 2 2005 Ci Of Tukwila l3UIUDING DTI, NION RECEIVED CITY OF TUKWILA JUN 0 2 2.005 PERMIT CENTER 1 EXPIRES: 4/24/ C? '7 33i /-1-7/7j bO(CisE z Z re JU O 0 to 0 w x w 0 ga • s u..< w a . w _ . z F- ' E-O w U 0 O - O 1-' w w F Li- 0 , ,z r =' z F1 peteg.wsw level %d 1 of 1 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks®Shearwalls 2002 May 31, 2005 15:30:14 30' I0 B -1 A -1 0' 5' 10' 15' 20' 25' 25' 20' 15' 10' 5' 0' peteg.wsr CO lMNY STORY INFORMATION Ceiling Level 1 Foundation BLOCK INFORMATION . Block :Block 1 Locat.ton[ft:] : Extent[ftj: Ridge Loc [ f t ] : Ridge Elev[ft] : SHEARLINE DIMENSIONS .Name Level Wall De:,ign Group(s) 1 2 1 WoodWorks® Shearwalls SOFTWARE. FOR WOOD DESIGN Location [ft] Y._ Y= 0.00 0.00 22.00 22.00 WINO SHEhF' LOADS !'lame' Building Lev Profile TrlbuCary Face Width[ft] Block 1 N Wall North 1 Line Block 1 N Wall North 1 Line Block 1 N Roof North 1 Line Block 1 N Roof North 1 Line Block 1 F Wall. East. 1. Line Block 1 E Wall East 1 Line Block 1 B Wall East 1 Line Fleck 1 E Wall East 1 Line Block 1 I~ Wall East 1 Line Block 1 E Wall East 1 Line Woodworks® Shearwalls 2002 STRUCTURAL DATA Floor /Ceiling Wall Building Story Elevation[ft] ilept.h(.in) Height[ft] Mnss[lbn] Shear[lbs] 11.67 10.0" 2.83 10.0" 8.00 21354 2135 2.00 Totals: 2135 4 2135 ROOF PANELS Overhang Mass 1 Stories Type Slope [Et] [ibs] 0.00 North Side 30.0 1..00 0 22.00. South Side 30.0 1.00 0 0.00 East Gable 90.0 1.00 1397 6.35 West Gable 90.0 1.00 1397 DESIGN SETTINGS Design Code: IBC Wind Capacity Increase: Shear = 1.40; C6C Panels = 1.50; Withdrawal = 1.60 Wind: Sheathing capacities are added together Seismic: Use greater of strangest or twice weakest sheathing capacities. Seismic Load Reduction Factor = 0.70 Shearwall Relative Rigidities based on Flexible Design Holddown Forces based on Applied Force Na:. Shearwall Plan = 4.00'; Height to Width Ratio = 3.50 SITE Il1FOAMATiO11 IBC Occupancy: Category I; ASCE Equivalent - Category II WIND: ASCE-7 '98 General analytic method for all buildings Design wind speed= 100mph; Exposure C; Partly Enclosed building SEISMIC: ASCE -7 98 Equivalent Lateral Force Procedure Use Group I; Seismic Design Category D; Site profile class D Spectral response accelerations Si = 0.400g, Ss = 0.750g Fundamental. period T: T used = 0.110s; Appro:d.mate Ta = 0.110s; Maximum T = 0.186s Re.l iabi J i y factor rho = 1.00; Response modification factor R - 6.00 MATERIALS by WALL'GROUP Wall • Sheathing [in] Fasteners: Spacing[in] Framing Members [in) Apply Grp Surf Material Thickness Or Size Type Edge Field Blkg Species ZX G Spacing Notes 1 Ext SS incl. OSB 7/16 Vert • 8d Nail 4 6 yes Hem -Fir's 0.43 24 1 • Notes: 1., Capacity has been reduced according to IBC spec.i.flc gravity adjustment. 0.00 0.00 22.00 22.00 LOADS PROJECT 0.00 -1 .00 -1.00 0.00 0.00 0.00 0.00 11.00 11.00 E: :tent [£t] Full Height Start End Sheathing [ft] 0.00 22.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Location[ft] From To 0.00 22.00 22.00 23.00 23.00 22.00 22.00 11.00 11.00 22.00 22.00 22.00 22.00 22.00 22.00 22.00 22.00 22.00 Magnitude Wind [1bs,plE,psf] Direction 60.7 Windward 37.9 65.3 21.8 60.7 37. 9 0.0 -49.9 0.0 -80.2 49.9 -0.0 80.2 -0.0 19.00 17.00 4.00 22.00 Leeward Leeward Windward Windward Leeward Leeward Windward Leeward Windward May 31, 2005 15:52:24 V __i Block 1 S Wall Block 1 S Wall Block .1 y' hoof Block 1 S Roof Block 1 W Wall Block 1•W Wall Block 1 W Wall Block 1 W Wall Block 1 W Wall Block 1 W Wall WIND C&C LOADS Name Block 1 N Wall Block 1 E Wall Block 1 S Wall Block 1 W Wall BUILDING MASSES Nara Shear Level Profile Tributary Location(ft] Line W.idth(ftI From To Wall B -1 B 1 Line Wall 2 -1 2 1 Line Wall A -1 A 1 Line Wall 1 -1 1 1 Line block 1 l) Roof b •. l,Lnt Block 1 E Roof 2 1 Line Block 1 S Roof A 1 Line Block 1 W Roof 1 1 Line Block 1 E Gable -S 2 1 Line Block 1 E Gable -N 2 1 Line Block 1 cN Gable -S' 1 1 Line Block 1 W Gable -N 1 1 Line SEISMIC LOADS Name South 1 South 2 'South 3 South 4 South 5 • West 1 West 2 West.3 West 4 West 5 West 6 South 1 South 1 :,'nat:I3 1 South 1 Went 1 West 1 West 1 West 1 Wert 1 West 1 Building Level Face North 1 East 1 South 1 West 1 SHEAR RESULTS by SHEARLINE Line Lev Aal1 Wind Total. •Grp. Dir. FHS 1 1' 1 Both 19.00 2 I 1 Both 17.00 A 1 1. Both 4.00 B 1 1. Both 22.00 DRAGSTRUT AND HOLDDOWN FORCES Line Line Line Line Line Line Line Line Lino Line Building Lev Profile Face South 1 Line South 1 Line South 1 Point South 1' Line South 1 'Point West 1 Line West 1 Line West 1 • Point West 1 Line • West 1 Line West 1 Point Magnitude [put] Interior End Zone 30.5 36.0 30.5 36.(i 30.5 36.0 30.5 36.0 WIND DESIGN FLEXIBLE DIAPHRAGM DESIGN 0.00 22.00 60.7 Windward 0.00 22.00 37.9 Leeward - J.00 23.(1(1 65.3 I.eeward -1.00 23.00 21.8 Windward 0.00 22.00 60.7 Windward 0.00 22.00 37.9 Leeward 0.00 11.00 0.0 -49.9 Leeward 0.00 11.00 0.0 -80.2 Windward 11.00 22.00 49.9 -0.0 Leeward 11.00 22.00 80.2 -0.0 Windward 0.00 22.00 0.00 22.00 0.00 22.00 0.00 22.00 -1..00 3.00 -1.00 23.00 -1.00 23.00 -1.00 23.00 0.00 11.00 11.00 22.00 0.00 11.00 11.00 22.00 Location[ft] From To -1.00 0.00 0.00 22.00 0.00 0.00 22.00 23.00 22.00 22.00 -1.00 0.00 0.00 11.00 22.00 22.00 0.00 11.00 0.00 22.00 23.00 22.00 Magnitude [lbs,pl£,psf] 160.0 160.0 160.0 160.0 240.0 240.0 240.0 240.0 0.0 -127.0 12'7.0 -0.0 0.0 -127.0 127.0 -0.0 Magnitude Elba, pit,psf] 33.6 44.8 221 33.6 221 33.6 44.8 -62.6 123 62.6 -44.8 33.6 123 Cumulative Shear Port:*: Shear Capacity I,pI.i1 Response V(lbs] Unit V /FHS(pif] Inter Etter Pert Total V /FHS /Tot 2129 96.8 112.1 462.2 1.00 462.2 0.24 2129 96.8 125.3 462.2 1.00 462.2 0.27 1800 81.8 450.1 462.2 1.00 462.2 0.97 1800 81.8 131.8 462.2 1.00 462.2 0.18 SHEARWALL SEGMENTS Nance Lev PYpe Wail f)Lnm.ru ion: (ft] F7t11 Height Pert Shear (_1 mi Opening (ft.] • Group Location Start End Sheathing Factor Force Capacity Width Height 1 -1 1 I 1 0.00 0.00 22.00 19.00 1.00 2129 8782 Opening 1 4.50 7.50 3.00 6.80 2 -1 1 I 1 22.00 0.00 22.00 17.00 1.00 2129 7858 Opening 1 5.00 7.50 Opening 2 14.50 17.00 A -1 1 I 1 0.00 0.00 22.00 4.00 1.00 1800 1849 Opening 1 4.00 20.00 16.00 6.00 8 -1 1 I 1 22.00 0.00 22.00 22.00 1.00 1800 10169 2.50 3.00 2.50 3.00 3/4 Level Location [ft] Wall 7 1 1 1 1 1 1 1 1 1 1 1 0.00 0.00 0.00 0.00 -.00 22.00 22.00 22.00 22.00 22.00 0.00 4.00 0.00 22.00 SHEAR RESULTS by SHEARLINE Line Lev Wall Wind Total Cumulative Shear Force Shear Capacity [Of] Response Grp. Dir. FHS V[lbs] Unit V /EHS[plf] Inter Exter Perf Total V/FHS/Tot •1 1 1 Both 19.00 2331 105.9 122.7 462.2 1.00 462.2 0.27 2 '1 1 Both 17.00 2266 • 103.0 133.3 462.2 1.00 462.2 0.29 A• 1 1 Both 4.00 949 43.1 237.3 462.2 1.00 462.2 0.51 1. 1 Both 1%.00 2759 125.4 125.4 462.2 1.00 462.•_ 0.21 SHEARWALL SEGMENTS • Name Lev Type Wall Dimensions [ft] Full Height Pert Shear [lbs] Opening [ft] ' • Group Location Start End Sheathing Factor Force Capacity Width Height 1 -1 1• • I 1 0.00 0.00 22.00 19.00 1.00 2331 137132 Opening 1 4.50 7.50 3.00 6.80 :2 -1 1 I 1 22.00 '0.00 22.00 17.00 1.00 2266 7858 .Opening J . 5.00 7.50 2.50 3.00 Opening 2 14.50 17.00 2.50 3.00 A -1. 1 I 1 0.00 0.00 22.00 4.00 1.00 949 1849 Opening 1 4.00 20.00 16.00 6.00 b - 1 1 1 22.00 0.00 22.00 22.00 1.00 2759 10169 DRAGSTRUT AND HOLDDOWN FORCES Level Location [ft] Wall Position on Wall 1 0.00 0.00 1 -1 1 0.00 4.50 1 -1 1 0.00 7.50 1 -1 1 0.00 22.00 1 -1 1 22.00 0.00 2 -1 1 22.00 5.00 2 -1 1 22.00 1 22.00 1 22.00 1 22.00 1 0.00 0.00 1 - 1 4.50 1 -1 7.50 1 -1 22.00 1 -1 0.00 2 -1 5.00 2 -1 7.50 2 -1 14.50 2 -1 11.00 2 -1 22.00 2-1 0.00 A -1 0.00 A -1 22.00 b -1 22.00 B -1 7.50 2 -1 14.50 2 - 1 17.00 2 -1 22.00 2 -1 0.00 A -i 1 4.00 0.00 A -i 1 0.00 22.00 8 -1 1 22.00 2 2.00 8 -1 Position on Wall Holddown Force [lbs] Dragstrut or Opening Shur Dead Uplift Combined Force[lbs] Left' W411 End 697 697 Left Wall End 897 897 69 Left Wall End £197 897 222 Left Wall End 897 897 Left Wall Nand L002 1002 Left Wa11 End 1002 1002 .142 Left Wall End 1002 1002 100 Left Wall End 1002 1002 100 1.4 -:0. Udall. End 101012 100 14 Left Wall End 1002 1002 Left Wall End 3601 3601 Left Wall End 3601 3601 1473 Left Wall End 655 655 Lett Wall End 655 655 or Opening Left Wall End Left Wall End Left Left Lett Left Left Left Left Left Left Left Left RIGfO l)IAPKKA(- M 1)P :SI -N Wall End Wall End Wall End Wall End Wall End Wail End Wall End Wall End Wall End Wall End Wald End Wall End (; )R1, )t 1349' 1 (:L)DO1N(i DESl.(M1 COMPONENTS AND CLADDING by SHEARLINE Fasteners [lbs] Name Level Wall Sheathing [paf] Force Capacity Response Group Force Cap. Resp End Int End Int 1 1 1 36.0 30.0 1.20* 36 30 60 0.53 0.45 2 1 1 36.0 30.0 1.20* 36 30 68 0.53 0.45 A 1 1 36.0 30.0 1.20* 36 30 68 0.53 0.45 Ft 1 1 36.0 30.0 1.20 36 30 66 0.53 0.45 •WARNING - Sheathing design capacity has been exceeded for Flexible Design and Rigid Design SEISMIC DESIGN F.'1..1•;ell13LZ 1)lAl21.11(A ;tit L)E.SZr;1J Holddown Force [lbs] Dragstrut Shear: lieacl 't)pl't.tr Combined 1?orce[lbs] 981 981 981 981 75 981 981 243 981 981 1066 1066 1066 1066 151 106G 1066 106 1066 1066 106 1066 1066 151 1066 1066 ' 1898 1898 1898 1898 777 1003 1003 1003 1003 SHEAR RESULTS by SHEARLINE Line Lev Wall Wind Total Cumulative Shear Force Shear Capacity [plf] Response 4/a Grp. Dir. FHS V[lbs] Unit V /FHS(plf] Inter. Exter Perf Total V /FHS /Tot 1 1 1 19.00 747 34.0 39.3 330.1 1.00 330.1 0.12 2 1 1 17.00 /4/ 34.0 44.0 330.1 1.00 330.1 0.13 A 1 1 4.00 747 34.0 186.9 330.1 1.00 330.1 0.57 B 1 1 22.00 747 34.0 34.0 330.1 1.00 330.1 0.10 } WARNI'IG design capacity has been exceeded. SHEARWALL SEGMENTS Name Lev Type Wall Dimensions [ft] Full. Height Perf Shear [1bs] Opening [ft] Group Location Start End Sheathing Factor force Capacity Width Height 1 -1 1 I 1 0.00 0.00 22.00 10.00 1.00 747 6273 Opening 1. 4.50 7.50 3.00 6.80 2 -1• 1 I 1 22.00 0.00 22.00 17.00 1.00 747 5613 Opening 1 5.00 7.50 2.50 3.00 Opening 2 14.50 17.00 2.50 3.00 A -1 ' 1 I 1 0.00 0.00 22.00 4.00 1.00 747 1321 Opening 1. 4.00 20.00 16.00 6.00 8 - 1 I I 1 22.00 0.00 22.00 22.00 1.00 747 7263 DRAGSTRUT AND HOLDDOWN FORCES Level Location [ft] Wall Position on Wall Holddown Force [lbs] Dragstrut Y. • Y or Opening Shear Dead Uplift Combined Force[lbs] 1 • 0.00 0.00 1 -1 Left Opening 1 315 315 1 0.00 4.50 1 -1 Left Opening 1 315 315 24 1 0.00 7.50 1 -1 Left. Opening .1 315 315 78 . 1 ..0.00 22.00 1 -1 Lett Opening 1 315 315 • 1 22.00 0.00 2 -1 ' Left Opening 2 352 352 1 22.00 • 5.00 2 -1 Left Opening 2 352 352 50 1 22.00 7.50 2 -1 Left Opening 2 352 352 35 1 22.00 '14.50 2 -1 Left Opening 2 352 352 35 1 22.00 17.00 2 -1 Left Opening 2 352 352 50 1 22.00 22.00 2 -1 Left Opening 2 352 352 1 0.00 0.00 A -1 Left Opening 1 1495 1495 1 4.00 .' 0.00 A -I Left Opening 1 1495 1495 612 .1 0.00 • 22.00 B -1 Left 'Wall End 272 272 1 22.00 22.00 B -1 Left Wall End 272 212 RIGID DIAPHRAGM DESIGN SHEAR RESULTS by SHEARLINE Line Lev Wall Wind Total Cumulative Shear Force Shear Capacity 1plf) Response . Grp. Dir. • FHS V[ibsJ Unit V /FHS[pIf] Inter Exter Perf Total V /FHS /Tot 1 1 1 19.00 818 37.2 43.1 330.1 1.00 330.1 0.13 •2' 1 1 17.00 795 36.1 46.8 330.1 1.00 330.1 0.14 A 1 1 4.00 394 17.9 98.5 330.1 1.00 330.1 0.30 B 1 1 22.00 1145 52.1 • 52.1 330.1 1.00 330.1 0.16 *,WARNING design capacity has been exceeded. SHEARWALL SEGMENTS Name Lev Type Wall Dimensions [ft) Full Height Perf Shear [lbs] Opening [ft] Group Location Start End Sheathing Factor Force Capacity Width Height 1 -1 1 I 1 0.00 0.00 22.00 19.00 1.00 818 6273 Opening 1 4.50 7.50 3.00 6.80 2 -1 1 I 1 22.00 0.00 22.00 17.00 1.00 795 5613 Opening 1 5.00 7.50 2.50 3.00 Opening 2 14.50 17.00 2.50 3.00 A -1 1 I 1 0.00 0.00 22.00 4.00 1.00 394 1321 Opening 1 4.00 20.00 16.00 6.00 B -1 1 I 1 22.00 0.00 22.00 22.00 1.00 1145 7263 DRAGSTRUT AND HOLDDOWN FORCES Level Location [ft] Wall Position on Wall Ho.lddown Force [lbs] Dragstrut Y. Y. or Opening Shear Dead Uplift Combined For.ce[lbs] 1 0.00 0.00 1 -1 Left Opening 1 344 344 1 0:00 4.50 1 -1 Lett Opening 1 344 1 0.00 7.50 .1 -1 Left Opening 1 344 1 0.00 22.00 1 -1 Left Opening 1 344 1 22.00 0.00 2 -1 Lett Opening 2 374 1 22.00 5.00 2 -1 Left Opening 2 374 1 22.00 7.50 2 -1 Left Opening 2 374 1 22.00 14.50 2 -1 Left. Opening 2 374 1 22.00 17.00 2 -1 Left_ Opening 2 374 1 22.00 22.00 2 -1 Left Opening 2 374 1 0.00 0.00 A -1 Left Opening 1 788 1 4.00 0.00 A -1 Left Opening 1 788 344 26 344 85 344 374 374 53 374 37 374 37 374 53 374 788 788 322 ii NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. rr hJ tJ 0 O O 0 0 N N 4 O O O Cri CO I r N r t" re re M rr rr A J r r J J A A rr J J �� /2 4 4.,Z , 2). /2 00E' /6/ 0/L // /4 _1 !/ = z c5 / 7`L = v L 4 v /) / z = 1U - 6 Z Cg . 6c.s/9 f L .. /a 4 P c =- l O /te e /G ,.js S.-, Ls) _ 72T /' G = 2 9 / ( �� % S8 ►� �C /s -e," - L .9 P-c R , 2, 4a 2 Ps/ y‘ t /S-C /,k 3 / gzz e " d_ ' ` S 2 d 0 ' / :)f, 6(�l/ 3 S� z U o 4 -P•Q Der)`- %s 4-- re QQ= J U 00 00 0 = w w 0 H I . ' HO Z D o , to 0 w W u' O .. w Z Cry C 7 C/1- O 1R-7- A e'• - e e/4-1) R e Z ed, A-, 72 i1 . -- z = /v p 4-, A G� do v vA a 33 /, 3 3 =- 3. / s,c as D p er/' c i z 2:S` // / S E c z 1z 6 = 0 00 co 0 W = WO co ▪ a 1- w Z0 W U O 1- W w H c u' O W U . o = � z 07 -28 -2006 PETE GIERE 4408 S 124 ST TUKWILA WA 98168 RE: Permit No. D04 -458 4408 S 124 ST TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the • provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 09/20/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: shall, t - ician Permit File No. D04 -458 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 -431 -3665 March 15, 2006 Pete Giere 4408 S 124 St Tukwila, WA 98178 City of Tukwila Department of Community Development Steve Lancaster, Director RE: Request for Extension Development Permit No. D04 -458 Giere Residence — 4408 S 124 St Dear Mr. Giere: If you should have any questions, please contact our office at (206) 431 -3670. Sincerel i arshall Permit Technician File: Permit No. D04 -458 P:Vennifer\Extension Letters\Pemuts\D04.458 Permit Extension.doc jem Steven M. Mullet, Mayor This letter is in response to your written request for an extension to Permit.No. D04 -458. The City of Tukwila Building Division will be extending the expiration date of your permit for an additional 180 days (through September 22, 2006). Page 1 of I 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 March 10 2006 Bob Benedicto Department of Community Development 6300 Southcenter Blvd #100 Tukwila, WA 98188 -8548 RE: Permit D04 -458 Sir: I am requesting an extension on this permit, which is for a detached garage for my house. The inspector is calling for some additional bracing on the gable ends of the trusses that I am not familiar with how to install (I am the homeowner acting as contractor). I have been requesting a friend with more framing experience to help me but he has been tied up with projects of his own. He can help me as soon as he can, but possibly not before this permit expires on March 26 of this year. Respectfully, Pete Giere 4408 S. 124 St Tukwila, WA 98178 206 - 234 -2481 clza &Od`-8° eleel-te 3/1 5/OG RE CEIVED _gommuNiTy )CP PA's" 0 .21 .U9 OCC 2 Af 091,W,c(p 02 -08 -2006 PETE GIERE 4408 S 124 ST TUKWILA WA 98168 RE: Permit No. D04 -458 4408 S 124 ST TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a• final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one or more extension of time for additiona perios not exceeding 90 days each. Extension requests must be in writiut' and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 03/26/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ii-Ao4L1,Q J ifer Marshall, Permit Technician xc: Permit File No. 004 -458 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 June 13, 2005 Mr. Pete Giere 4408 South 124 Street Tukwila, WA 98178 RE: CORRECTION LETTER #2 Development Permit Application Number D04 -458 Giere Residence — 4408 South 124` Street Dear Pete: This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time, the Planning, Public Works and Fire Departments have no comments. Building Department: Allen Johannessen, at (206) 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messen.eer service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, Stefanie Spencer Permit Technician encl xc: File No. D04 -458 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director sks T: \Links\Docs\DO4- 458\DO4 -458 - Correction Letter #2.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Y Building Division Review Memo Date: June 9, 2005 Project Name: Giere Residence Permit #: D04 -458 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner A follow -up Building Division plan review has been conducted on the subject permit applications. Only two items of concern remains. Please address the following comment with revised plans, specifications and /or other applicable documentation. 1. Page (2) Section B -B shows the attic has changed by eliminating the I -Joist and collar ties, creating partial attic storage with the use of trusses. In addition, the Garage Attic Floor Framing Plan showing the attic floor is not consistent with the revised Section B -B details. Provide framing plan details that show the new attic and roof framing, consistent with the revision. 2. Page (2) Section B -B shows a note added which indicates "Attic Trusses (By Others) ". The trusses shall be engineered trusses preferably by a truss manufacture. Provide the necessary reference notes on the plans for engineered manufactured trusses or indicate type of trusses with engineering. Revise Section B -B details with elevation details to show intended truss. Should there be questions concerning the above requirements, contact the Building Division at 206 -431 -3670. No further comments at this time. • Page 1 February 10, 2005 Mr. Pete Giere 4408 South 124 Street Tukwila, Washington 98178 RE: Dear Pete: Sincerely, Stefania Spencer Permit Technician encl xc: File No. D04 -458 City of Tukwila Department of Community Development Steve Lancaster, Director CORRECTION LETTER #1 Development Permit Application Number D04 -458 Giere Residence — 4408 South 124` Street This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time, the Planning, Fire and Public Works Departments have no comments. Building Department: Allen Johannessen, at (206) 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have • enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 - 7165. Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 r .....�..., ,..�.xa..,i:�.�v., .: ;r . .i .irdjaib;.: ,.a;,ik:, ., 1.;�.J' -: „ acs . .,.�.�c::..�saa,:;.�m:s,n. °t.,: , .:u:t:� »i,.s�.u.. Misr:: r.. N:. y .su'.uu::::;.afi:114e:t.suars. • Page 1 Building Division Review Memo Date: February 4, 2005 Project Name: Giere Residence Permit #: D04 -458 Plan Review: Allen Johannessen, Plans Examiner A Building Division plan review has been conducted on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (Drawing and structural calculations sheets shall be original signed wet stamp, not copied.) 1 On sheet A2, MAIN LEVEL FLOOR PLAN, a PSL beam was indicated in ink pen on the plans which is also indicating a change for the garage door opening. Provide calculations for the sizing of the PSL BEAM. 2 The brace walls on either side of the garage door need clarification and sizing in compliance to the 2003 -IRC R602.10.6 for Alternate braced wall panels. The panels need to be a minimum size of 2' 8 ". The foundation plan shall also reflect the changes. Should there be questions concerning the above requirements, contact the Building Division at 206 -431 - 3670. No further comments at this time. Tukwila Building Division Allen Johannessen, Plan Examiner ,4i;. Nr Xll.'..: r4 Ji:..'. wx '%,Saaai.u »'' 'r'a r December 29, 2004 Mr. Pete Giere 4408 South 124 Street Tukwila, WA 98178 Dear Pete: Sincerely, Stefanitf'Spencer Permit Technician Enclosures File: Permit File No. D04 -458 Ciiy of Tukwila Department of Community Development Steve Lancaster, Director RE: Letter of Incomplete Application # 1 Development Permit Application D04 -458 Giere Residence — Garage — 4408 South 124 Street This letter is to inform you that your application received at the City of Tukwila Permit Center on December 23, 2004, is determined to be incomplete. Before your application can continue the plan review process the following items need to be addressed: Planning Department: Brandon Miles, at 206 431 -3684, if you have questions concerning the attached memo. Please address the above comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 433 -7165. Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431 -3670 • Fax: 206 - 431.3665 DATE: CONTACT: RE: ADDRESS: city of Tukwila Department of Community Development December 28, 2004 Peter Giere D04 -458 4408 S. 124 St PLANNING DIVISION COMMENTS Please review the following comments listed below and submit your revisions accordingly. If you have any questions on the requested revisions, Brandon Miles is the planner assigned to the file and can be reached at (206) 431 -3684. 1. Provide the square footage of the foot print of the existing house. 2. Provide an estimate for the total amount of cut/fill for the project. 3. What will the "storage" area above the garage be used to store? Steven M. Mullet, Mayor Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DEPARTMENTS: Vi c; 1p2 Buil • in % Division Public Works ❑ PERMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D04 -458 PROJECT NAME: GIERE RESIDENCE SITE ADDRESS: 4408 SOUTH 124 STREET Original Plan Submittal DATE: 06 -17 -05 Response to Incomplete Letter # X Response to Correction Letter # 2 Revision # /before permit is issued Fire Prevention ❑ Planning Division ❑ Structural ❑ Permit Coordinator X DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 06 -21 -05 Complete 2( Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R9UTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07 -19 -05 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Documents/rouling sllp.doc 2.28.02 PERMIT COORD COPY DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D04 -458 DATE: 06 -02 -05 PROJECT NAME: GIERE RESIDENCE SITE ADDRESS: 4408 SOUTH 124 STREET Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision #_after /before permit is issued DEP ' RTME TS: Bulisi Div ion ed r1 0 Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator [� DETERMINA ON OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ APPROVALS OR CORRECTIONS: PERMIT COORD ppy. PLAN REVIEW/ROUTING SLIP REVIEWER'S INITIALS: Documents/routing slip.doc 2.28 -02 PERMIT COORD COPY DUE DATE: 06 -07 -05 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROOTING: Please Route , Al Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 07 -05 -05 Approved ❑ Approved with Conditions ❑ Not App roved ( attach comments) Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 6— / 3-65" Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: .5 ACTIVITY NUMBER: D04 -458 PROJECT NAME: SITE ADDRESS: Original Plan Submittal Response to Correction Letter # GIERE RESIDENCE 4408 S 124 ST DATE: 1 -27 -05 X Response to Incomplete Letter # 1 Revision # After Permit Issued DEPARTMENTS: 0v16 Buildi g D vision Public Works PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ►:i VI' Structural M it 2 -0 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete P p Comments: Documents/routing slip.doc 2 -28 -02 APPROVALS OR CORRECTIONS: Fire Prevention n ❑ C Planning Division Permit Coordinator DUE DATE: 2 -1-05 DUE DATE: 3-1 -05 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROU ING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: Approved n Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: 4`(b - 6 Bldg tt Fire ❑ Ping ❑ PW ❑ Staff Initials: qs{ DEPARTMENTS: Building Division Public Works Documents /routing slip.doc 2.28.02 0 APPROVALS OR CORRECTIONS: 'PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D04 -458 PROJECT NAME: GIERE RESIDENCE SITE ADDRESS: 4408 S 124 STREET DATE: 12 -23 -04 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision #afterTbefore permit is issued '5 ( iz Fire Prevention Structural ❑ DETERMINATION OF COMPLETENESS: (Tues., Th rs.) DUE DATE: 12 -28 -04 Complete ❑ Incomplete d l Z -z � Plan g Division G 8 Permit Coordinator Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: 4 22 = 29 ' 04 i LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping,81 PW ❑ Staff Initials: SK5 TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 01 -25 -05 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: '' 1T COOF7 COPY DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 17-' Plan Check/Permit Number: D04 -45 8 ❑ Response to Incomplete Letter # ® Response to Correction Letter # ❑ Revision # after Permit is Issue Revision requested by a City Building Inspector or Plans Examiner Project Name: Giere Residence Project Address: 4408 South 124 Street Pete Giere Phone Number: min -\tt-0- V\ C5 I Li, C5 Contact Person: Summary of Revision: \applications \farms - applications on line\revision submittal Created: 8 -13 -2004 Revised: C I T P OEF j1 i 1-A 7 2005 PERMIT CENTE Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: �Cr%�=—' Entered in Permits Plus on 6 -/7'3 i.i :�:... City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ❑ Response to Incomplete Letter # Response to Correction Letter # ❑ Revision requested by a City Building Inspector or Plans Examiner e G + c 61% ere- s, 61; 441 COn{ Ic kc n t W PIA,, 61.^ CG n}4frt. ;o. CGICv � a\f 1 C/t Steven M Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 2 . 3v^1. o'er Plan Check/Permit Number: Pa — 1 S 2 w • w ❑ Revision # after Permit is Issued 0 O — O 1-- w • w LLO uj Z Project Name: Project Address: ( t 1 OS S• 129.0 T V k t.-►1 �, '1 11& Contact Person: Phone Number: 2O - 23y - 2'4 8 U - = Z Summary of Revision: Per c Lz a �j fc RE CEIVCp CITY OF TUKWILA JUN - 2 2005 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: S Pi' Entered in Permits Plus on lo'0" \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: nGa% �i . ?»XV:r;I.:L:Ur o.,4,::x.:.iiL. w;:u:t....+1.r.i. N:.:..11:.`1++Ia��eyl;i i%" �.N:.k��3t:�5 ie'C.:'fMUAq:Y�k4Y;+r+4sl xFir y.e.'iCc+:TJa; :y,'�Sk.E „'q'.Y:) .. ':+:ih%U Ei,�iiti:e�"w.w�ti�w Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /tvtivw.ci.tukwila.tiva.us after Permit is Issued l� T-4h 1 f �i Jcrc Feeta,c of c,yi +;As z ) &'7Dv/ U "r Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 1-27 -05" \ applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Plan Check/Permit Number: D04 -45 8 ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: GIERE RESIDENCE - GARAGE Project Address: 4408 SOUTH 124 STREET Contact Person: Pete Giere Phone Number: 204-234- 21 81 Summary of Revision: Se C f ISM i e5 h t v;);0 c, U► +5 kcu e em-r/6-0 IS C4 pct (orc (.� r -d? ?) 544( Ay( Or 161 L.4 4 *Id Fe' 1 cII Trek � we /54+ try i, Nark. (44 it' btil(r+vt# aid s4 firm , I) Ves-7 liMi��d Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision 614,o-ek Steven M. Mullet, Mayor Steve Lancaster, Director INCOMP ETE ITR�t____� D04- 418 t;lgy lL4 Al 2 r' 2005 PERMIT CENTER STATE OF WASHINGTON) COUNTY OF KING ss. CITY OF TUKWIL4 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO.: goy - 45 . g f t_ 6 i rc_ , states as follows: [please print] 1. I have made application for a building permit from the City of Tukwila, Washington. Permit Center /Building Division: 206 - 431 -3670 Public Works Department: 206 - 433 -0179 Planning Division: 206 -431 -3670 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. I , and will therefore not be performed by a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. \applications \8 -2004 affidavit in lieu of contractor registration A " IC Signed and sworn to before me this 2Mt17 day of June. , 20 05 . a 4 ' 401 , C,4_ , � NOTARY PUBLIC in and for for the State of Washington, Residing at Atli n, Ki n9 ,County. Name as commissioned: AlIC- A, Deacy My commission expires: -16-08 pxi wyo.spm ' 18.27.090 Exemptions. This chapter shall not apply to: 1. 2. An authorized representative of the United States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district or other municipal or political corporation or subdivision of this state; 3. Officers of the court when they are acting within the scope of their office; 4. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 5. Any construction, repair or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 6. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of the structure; 7. Any construction, alteration, improvement or repair of personal property, except this chapter shall apply to all mobile, manufactured housing. A mobile /manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 8. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 9. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 10. Any work or operation on one undertaking or project by one or more contractors, the aggregate contract price of which for labor and materials and all other items is less than $500.00, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in all instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into \applications \8 -2004 affidavit in lieu of contractor registration contracts of amounts less than $500.00 for the purpose of the evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 11. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except then any of the above work is performed by a registered contractor; 12. An owner who contracts for a project with a registered owner; d Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but his exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 14. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 15. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his license; 16. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; 17. Contractors on .highway.projects who have been prequalified .as required by chapter 13 of the Laws of 1961, RCW 47.28.070 with the department of transportation to, perform highway construction, reconstruction, or maintenance work. WIN rrrErnIN N■ir■i■�i•■r■■rrMR■ ■E•rrr Ell INNlr III MENM 1111 off Nil MEN In Ili NINE MEMO ME NMI MINI ENI NE INN MIMEO! E ■ i E•• rrINElr■ ■I■■N■■■■■■NEENNI■■EENEEE■■E■■II � lEt ill N• ••1 NE MINE EN NE NM in Er No Ell NE MEN El ..r..111NENEENNEE, ENEN■■■■■■■■■r■■■■■EINIEE N r MEN rr INN rrfl1111 EN NI MIME NMM■ NUM Ell REEINEEEnENEINEENIENINENIIIINNENENEINEINNENENNEENEEN IIII 1111 MN IRE EN Nu EN MN NE EN NE NE NI NE Eill pm NE mom Num mom EN NE In Mom 11111•MNI rr Ell r rill No EN Ilmi EN IIIE NEIN Ell NE Ell r Ell Nit Ell • ■ ■■•••• ••r••∎■••••E••••••l•N•••• •••••••11 MIrrrl•rMEN■rrrrrrrMrrMEO M�N� 1E ■ENEENI r•■EEr rr ■■NE>•EENEEE■■EN■EENEN1• Ell liaN MINIM Ell E■■ INN Ell Ell IMMUNE ME■l1DM■ENME III a r L r r .SLAB FR ELEVATION N mlfinm r- rr mum MEIMMuMENE•r••1rriMI• r rrNEENNEEN % •rrrrr rrrrNE ■r•Er••■•t•■• ••E•■•••••••••■EE- E•- -- E•••■• •/- NEE N EM•■r•■r•••••••■••••■- N■r•• -EM_■ ■•••••■•r•••■•• ••••••••■•mminN•NENNEN , MEIMI NrErrMEME ME rEir MINE rr•■E■rrrr• ■■ ■r■•ri■r MEN rr■■rr■ERi■•m•rwilmilim• Emil - -•■EES NEENNlM■r■ittEN■• Ell •■EMME Ell r Ell ■■•■■r•>•1•IIIIM NIUME1.1•••••■•••l•••• ••E• NOME NM= all ME NM MIs•MN<rNIN■••- Elr•• MIME r■ r •r •r •r r �rir■mrir r rim 22to' /! Fir 7 ' OVRHD. r LEFT ELEVATION • • I sa FINISHED GRADE r L 8 12 RIGHT ELEVATION 22s-0 FRONT ELEVATION • VERSION 9 = GARAGE DOORS IN SAVE SIDE 1x8 FASCIA HORIZONTAL SIDING BM6' OVERHANG 0" CORNER BOARD rrirN��i ■��rN■ NOM r■.r>rr•■r■i r ` ■EMENIMENMNNMIEE•IN�i■ ` ii r■E`■r NI N MIMI■rNB■■-ir ■Errs r r r rN ■___MN NMM•• MI •• ••r•r•M•rf M MN ill M■ENMEMIl■ 8 op dmO M MEI WIM■r•■Err Ell Ili iii i■ri■ IN■�r■■NIMuEll1r.�I rf IIENE Ell ME Ell MEN Nu En 110 El ME NII NE iEll IIE Ell IIE Ell IIE Ell ME EN IIIE EN NUEIinMiEEN r rl�■r �iN■iNrillrr rr�■ ENIIENI �i r rIIIEi i■■Ellr r i t � t • l 4 r L _J • NlrErrE•NErar••rEN■■rirEll II Ill •rrr •■`am ` ■ m • ��—B�� r •— N ■■ ■■ • =i •• ■i •■ NEENIS NNEMN r>rr•Nrrr••E E N_••r•l—•N— ■•-- l■■ ■•N• -- ErE•MtrrE•rr -NlNEM ■■■ rirMalin mmil• MINAS i r`ttl•rtENN•rIrrrNN Man rin ■•----•E••••••-••• MORN •••r- _uNI «1••• • REAR ELEVATION t i r � L RIGHT ELEVATI( Pion MOW apptr ' - !object to errors and anise oN. Appel of con:* - ::i documents does not authorIN the violation of adopted code or ordinance. Rerelpt ppepproved Field Copy and conditions is admawbd 4 cr Prepared by: Bruce S. MacVeigh, P.E. 14245 59th Avenue S. Tukwila, WA 98168 (206) 242 -7665 City of 'Mae BUILDING DIVISION ele OVERHANG .L NO £ 7N /• = 20 , ZZ' . ' 1 j rel tA it; z?"4 c, cet -. 34 ri„,44 •fi �4 � GABLE VENT MIN. VENT AREA m 230 8Q. IN. PER GABLE �C/�OpN�T. SOFFIT VENT FINISHED GRADE , %_ ax .1\ Z •• 1� NA a ok r Taal ID 0: 017900-0555 MD' l I PLAN New One Stew Game 4108 124th Street Tukwila. WA R EVISIONS -'tar - - -:- :n!l bo mode to the scope : ^::t prior approval of ._..' :'sing Division. NOTE: r:;:1 requ :re a nevi plan submittal and nu:y inc;ude add tonal plan revie.v fees. SEPARATE PERMIT REQUIRED FOR Mechanical i Hethkal d Plumbing Gas Pip!ng City Of Tukwila BUILDING DIVISION r � - Naze: //7PERV /a 1S S /TE AREA S REprA SIJBS7•4N7 /ALL `/ SAME AS W /7/-/ PR FV /a v5 GARAGE AND lire IVE WAY. Client Pete Gieare 4408 S. 124th Stow Tukwila, WA 98178 (om) 234-2481 I () S: ..•% C 3/ ,ergy'05_ alb CORRECTION • Li L CO_ LEFT EL EVATION � :.; . IN 22 2 °a - Is Jo, • 0 II 01 0 �P G=I o M IT CENTER CO RE CT CE jo LT 1 RECEIVED Y OF TUKW A JUN 17 20e6 Doi -458 • 4 S 4 4'•6" //,' x 7 OVERHEAD I DOOR I GARAGE FL T S R PLAN I 2 GARAGE ATTIC FLOOR FRAMING P NOTE: FLOOR JOISTS ALWAYS RUN PERPENDICULAR TO RIDGE UNE. TYPICAL - BOTH VERSIONS MATERIALS by Wall Grp Surf Mat 1 Ext SS Notes.: 1. Capacity o R 6c h Ip/v r /20 r o.► r 4 /6" a l a V . • • 2 -0u V • TYPICAL GARAGE FLOOR : 4" CONCRETE SLAB 6" X 6 WIRE REINFORCING MESH COMPACTED GRANULAR FILL 511 n. /G' D ' D.PDP /N Sl2/'7WAL L AD.. DDD.e FOUNDATION PLAN TYPICAL a BOTH H VERSIONS SECTION A-A • • z. 4. 4' 4. i4 4. 4. 4' 4. 4' �4• 4. 4 • WALL GROUP Sheathing (in) Fasteners: Spacing[in) Framing Members [in) Apply erial Thickness Or Size Type Edge Field Blkg Species G Spacing Notes incl . OSB 7/16 Vert P-d Nail 4 6 yes Hem -Fi rr2 0-43 24 1 has_ been reduced according to IBC specific gravity adjustment. /fo (SEE SECT /ON.3 Ti /lS SHC'L T STAID /4 f,/OLD DDIUNS z tot DESIGN SE T T D ;. Destrja C'r_'i': IBC Wind Capacity increase: Shear = 1. -u; C& Fa eis = i.5i,; Withdrawal = 1.60 Wif. .d: SiteaLiiii& j capai are added Cuyelher Seismic: Use jrcatcr :.f strongest or twice weakest sheathing capacities. Seismic Load Re- ducti,n Factor = 0.70 Shearwali Relative :rigidities based on Flexible Design No 1d;own Forces based on Atl i ed Force Max Shearwail Offset: Plan = 4.00'; Height to Width Ratio = 3.50 REC -� ApN G oR SITE 1NttiC MAN ON IBC Occupancy: Category I; ASCE Equivalent - Category II WIND: ASCE -7 98 General analytic method for all buildings Design wind speed = 100mph; Exposure C; Partly Enclosed building SEISMIC: ASCE -7 98 Equivalent Lateral Force Procedure Use Group I; Seismic Design Category D; Site profile class D Spectral response accelerations S1 = 0.40Og, Ss = 0.750g Fundamental period :: :' used = 0.1.1.0s; Approximate Ta = 0.110s; Maximum T = 0.186s net i abi 1 i y factor rho = 1.00: Response modi fi ca t I on factor R - 6.00 . . 3/4" T & G PLYWOOD SUBFLOOR INSULATE PER BUILDER . d7 TYPICAL 2x4 EXTERIOR WALL VINYL OR WOOD SIDING 112" PLYWOOD SHEATHING Cow 7 //!0" aS8 2x4 STUDS at 18" o.c. D,e ¢ �� P/l'AL INSULATE PER BUILDER e- TYPICAL SILL ASSEMBLY: . 4 /1/2" DIA. ANCHOR BOLT 72' ac. ;./ � � 2x6 PRESSURE TREATED SILL PLATE 114" SILL GASKET TOP Q FAT SS x /3Z R ‘LU[4on 2.4 K) (2) 2 X10 LVL HEADER ABOVE GARAGE DOOR TOP_OF_KIUN_DATKIN TOP OF FOOTING DIPFES :a4 .. 1/2" CDX PLYWOOD SHEATHING Aura Vhciv Eti 65-0 W A 77/C 7 'L'5SES <BY LI7A/ERS LOCATION GENERAL NOTES: • �•e s' a •e DESIGN LOADS C. .. RIDGE VENT •• a .• p. BEAMS STUDS SILLS, PLATES RIDGE BOARDS SHEATHING SUBFLOOR vND)5TOR2W.b S&L . • A 2 - CD/1P�1 CTED EACICE /LL Z � SHINGLES WOOD OR CARPET DEAD LOAD S 20 15 LIVE LOAD (PS9 30 40 TOTAL (PS9 45 55 MINIMUM SOIL BEARING PRESSURE a 3 PSF Z, voo • A ROOFS FLOORS n SLAB W/ kV /RE FABP /e NESM 4 e24" C725 SECTION Era TYPICAL - BOTH VERSIONS SPRUGE D. HEM -FIR #2 SPRUCE TILE, SLATE OR STONE 25 40 85 • a .• Ir a W4 /D "t/RS. 8' CODE' VIEMZ F OR COMPL jp NCE 1 J111V 2 2 2005 I _ _ E ((1 p F� f , l&1 I ~ T/. S1 OD'd 1 • MATERIAL Fb PS) 1 sso 1000 SPRUCE 1000 %s" COX (DR 7 //6 "OSB) T&G C EIL.INGS PLASTER 10 20 30 11-/ CL /PS A7 AL7. 7ZPSSfS Z29 MN. FAN: MADE /!v" SEL STORY 4C-X A7/ON j WALL FDUND 1 E 1.5X'0 1.2X108 1.2Y,10 8 1.2X10 8 1.0 ALL WORK SHALL COMPLY WITH AU. APPLICABLE CODES, REGULATIONS 8 ORDINANCES, WHICH SHALL GOVERN OVER DETAILS SHOWNE IN THESE CONSTRUCTION DRAWN GS. 2.0 BUILDER TO BERIFY ALL DIMENSIONS AND MAKE WORK AGREE. 3.0 NOTE FRAMING SPECIFICATIONS ON THIS SHEET. 4.0 ALL HEADERS EXCEPT GARADE DOOR OPEINGS TO BE (2)2 x 10. 5.0 FOR ELECTRICAL REQUIREMENTS, BUILDER TO CONSULT A QUALIFIED ELECTRICIAN. 1LN O C44 tNI i : CO J a