HomeMy WebLinkAboutPermit 0068 - Southcenter Mall - Dr Pearl - RemodelThis record contains information which is exempt from public disclosure
pursuant to the Washington State Public Records Act, Chapter 42.56 RCW
as identified on the Digital Records Exemption Log shown below.
1 '
Dr Pearl
880 Southcenter Mall
RECORDS DIGITAL D- ) EXEMPTION LOG
THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION
Page Code Exemption = 8rlef E plainatoty Desclriptim Statuteftle
The Privacy Act of 1974 evinces Congress'
intent that social security numbers are a private
concern. As such, individuals' social security
Personal Information —
numbers are redacted to protect those
Social Security Numbers
individuals' privacy pursuant to 5 U.S.C. sec.
5 U.S.C. sec.
2
DR1
Generally — 5 U.S.C. sec.
552(a), and are also exempt from disclosure
552(a); RCW
552(a); RCW
under section 42.56.070(1) of the Washington
42.56.070(1)
42.56.070(1)
State Public Records Act, which exempts under
the PRA records or information exempt or
prohibited from disclosure under any other
statute.
Redactions contain Credit card numbers, debit
card numbers, electronic check numbers, credit
Personal Information —
expiration dates, or bank or other financial
RCW
DR2
Financial Information —
account numbers, which are exempt from
42.56.230(5)
RCW 42.56.230(4 5)
disclosure pursuant to RCW 42.56.230(5),
except when disclosure is expressly required by
or governed by other law.
BUILDING PERMIT
Applicant to complete numbered spaces only.
JOB ADOR E55
880 Southcenter Shopping Center
LEGAL
1 DESCR.
OWNER
MAIL ADDRESS
Dr. Alvin Pearl, Optometrist
CONTRACTOR
3 Ernest E. Peterson
ARCHITECT OR DESIGNER MAIL ADDRESS
4 John Rushmore & Associates 206 J.S.
ENGINEER MAIL ADDRESS
LENDER MAIL ADDRESS
USE 01' BUILDING
7 Optometrist
LOT 140. SLK
Class of work: ❑ NEW ❑ ADDITION (ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE
Describe work: Remodeling to include removal of interior walls
10 Change of use from Square feet — 660
Change of use to
11 Valuation of work: $ 2
SPECIAL CONDITIONS:
— As R5c 4 TArliv
APPLICATION D B" PLA BY
TRACT
MAIL ADDRESS
16638 SE 9th Bellevue
NOTICE
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMB-
ING, HEATING, VENTILATING OR AIR CONDITIONING.
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC-
TION AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A
PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM-
MENCED.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS
APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.
ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS
TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED
HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT
PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE
PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING
CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION.
SIGNATURE OF OWNER (IF OWNER BUILDER)
SIGNATURE OR AUTHORIZED AGENT (DATE)
CIT . DF TUKWILA BUILDING PL, ..MIT
14475 - 59th Ave. So. / Tukwila, Washington 98067
Ditty Bldg Bellevue GL42462
PLAN CHECK FEE 11.50
Typo of
Const.
Fire
Zone
FIRE DEPT.
No. of
Dwelling Units
ZONING
ZIP
Size of Bldg.
(Total) Sq. Ft. 0
Special Approvals
HEALTH DEPT.
SOIL REPORT
OTHER (Specify)
FOUNDATION
FRAMING
FINAL
PHONE
SH6 -0359
PHONE
PHONE
- Al
OCCUPANCY PERMIT REQUIRED
DATE
20 January 1972
SEE ATTACHED SHEET)
Occupancy
Group
No. of
Stories
WHEN PROPERLY VALIDATED ON THIS SPACE) THIS IS YOUR PERMIT
PHONE
LICENSE NO.
LICENSE NO.
LICENSE NO.
BRANCH
Tax No. C- 600 - 055 -548
PERMIT FEE 23.00
F
BUILDING
PERMIT NO.
N 068
Division
2
Max.
Occ. Load �a'
Use p Fire Sprinkler; Zone CSR, Required llld�ies ❑No
OFFSTREET PARKING SPACES:
Covered j Uncovered
Required
Not Required
Approved
PLAN CHECK VALIDATION cK. M.O. CASH PERMIT VALIDATION cK' M.O. CASH
1 ,//. -s � - //�7 ' /' i & C � ,
Mr. Ernest E. Peterson
1663$ S. S. 9th
Bellevue, Washington
Dear Sir:
A Plan Check of your proposed remodeling job at the Southcenter Shopping
Center has revealed the following deficiencies:
1. The building lies in Fire Zone 01, therefore all wood used in
this job must be fire treated for no less than a one (1) hour rating.
2. In several details, -' - inch Gypsum Board is called for. This
is not allowable. All Gypsum Board must be of a minimum 5/8 inch
thickness to meet the Fire Zone #1 requirement. (See short vertical
wall detail in section "C ".)
3. At the new location of the sink the surrounding wall must be
of water - resistant wall board or the wall finish must be non- absorbant
type.
4. The Fire Protection Sprinkler System must be checked and
approved by the City of Tukwila Fire Marshal before an occupancy permit
will be issued.
5. Occupancy during construction is not permitted.
6. Temporary occupancy will be allowed provided:
a. A solid wall partition is constructed to separate the
construotion area from the occupied area. This partition
should have a door access and is understood to be a temporary
structure. Such a partition shall be si :bject to approval by
the Fire Marshal and /or the Building Official.
b. That the sprinkler system be completely operable subject
to the approval of the Fire Marshal.
c. Before a occupancy is resumed, the Fire Marshal and the
Building Official must be notified, and inspection held and
approval to occupy granted.
Your willing compliance with those conditions will be appreciated.
JER /ma
CC: Hubert Crawley
January 21, 1972
Very truly yours,...
John E. Richards
Office Engineer