Loading...
HomeMy WebLinkAboutPermit D03-003 - PITNEY BOWES - SEISMIC UPGRADESPITNEY BOWES 116 ANDOVER PK E D03 -003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223000060 Address: 116 ANDOVER PK E TUKW Suite No: Tenant: Name: PITNEY BOWES Address: 116 ANDOVER PK E, TUKWILA WA Owner: Name: PITNEY BOWES PROPERTIES INC Address: MSC 1902, ONE ELMCROFT RD Contact Person: Name: JAY MYLAN Address: 12511 238 ST SE, SNOHOMISH WA Contractor: Name: MY -LAN COMPANY INC Address: 12511 238TH ST SE, SNOHOMISH, WA Contractor License No: MYLANCI009DC DEVELOPMENT PERMIT DESCRIPTION OF WORK: VOLUNTARY SEISMIC UPGRADES OF EXISTING OFFICE BUILDING Permit Number: D03 -003 Issue Date: 01/14/2003 Permit Expires On: 07/13/2003 Phone: Phone: 206 - 954 -7444 Phone: 360 668 -4455 Expiration Date: 02/26/2004 Value of Construction: $29,500.00 Fees Collected: $1,175.14 Type of Fire Protection: SPRINKLERS Uniform Building Code Edition: 1997 Type of Construction: Occupancy per UBC: 0016 Public Works Activities: Curb Cut/Access /Sidewalk/CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N Water Meter: Channelization / Striping: ** Continued Next Page ** doc: Devperm D03 -003 Printed: 01 -14 -2003 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Signature: Print Name: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 D03 -003 Date: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 01 -14 -2003 Parcel No.: 0223000060 Address: 116 ANDOVER PK E TUKW Suite No: Tenant: PITNEY BOWES doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS D03 -003 Permit Number: D03 -003 Status: ISSUED Applied Date: 01/03/2003 Issue Date: 01/14/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206 - 835 - 1111). 4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 5: Bolts installed in concrete shall be special inspected (UBC Sec. 1701.5.2). 6: When special inspection is required either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name, permit number and type of inspection being performed. 7: The special inspector shall submit a final signed report stating whether the work requiring special inspection was, to the best of the inspector's knowledge, in conformance with approved plans and specifications and the applicable workmanship provisions of the UBC. 8: Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 9: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 10: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 13: * ** SPRINKLER SYSTEMS * ** - UFC ARTICLE 10 - NFPA 13 14: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. 15: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 5.5.3.1) 16: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 17: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 18: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 19: * ** BUILDING CONSTRUCTION * ** - (UFC, UBC) 20: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 21: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Printed: 01 -14 -2003 22: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 � A /c)//e?te D03 -003 Printed: 01 -14 -2003 V.wll}..14. .��a.:..A.i.N..«w.wtir:or. G:✓cw a. +uv..:i .a..i..:,r:i.�.�..i « »�. Project Name/T . r t - ' Site Address include suite nu */ er) - Air .A _ ./t i • Existing use: ❑ Retail 171 Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel Ft Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel f3a, Office ❑ School /College/University ❑ Other •';r:. �., , Va e of C o • struction: Tax Parcel Number: Property • ner: Existing fire protection features: 91 sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Will there be storage of flammable/combustible hazardous material in the building? ❑ yes p no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets / Phone: Street Addres ■ / C - 2 Fax if: Cont actor: ae A 66 • �. City State /Zip: Phone -•- a'D._ a - ` .s Fax ft: It -‘4 l 97C Street Address: _ Arc itect: Phone: Street Address: City State/Zip: Fax #: En the r: g �/ 2-x, �t �ss . - /./.J , -L- Phone: PCS 3 93 -e y �o Street Addres / / City a •: Fax #: -3 Conta • rson; / w - / Phone: Street �tldress: , City State/Zip: Fax �� Descripti of work to be done (please be s ecific): - �i- ''41.1-- - // 41.i% ��� � i • Existing use: ❑ Retail 171 Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel Ft Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel f3a, Office ❑ School /College/University ❑ Other / Building Square Feet: / existing No. of Stories: L. Area of construction (sq ft): / �•a Will there be a change of use? ❑ yes ® no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes Ett no Existing fire protection features: 91 sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Will there be storage of flammable/combustible hazardous material in the building? ❑ yes p no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUUWILA Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Number: D o 3 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE /CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews maybe determined by the Public Works Department) ❑ Curb cut/Access /Sidewalk Size(s): Cut cubic yds. 0 Fill cubic yds. ❑ Sewer Main Extension CI Water Main Extension 171 Flood Control Zone 171 Channelization /Striping CI Fire Loop /Hydrant (main to vault) #: CI Land Altering 0 Cu ❑ Sanitary Side Sewer #: ❑ Storm Drainage ❑ Street Use ❑ Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous El Landscape Irrigation O Public O Public O Private O Private 0 Water Only ❑ Hauling Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: 3-03 Date application expires: '7-3 Application taken by: (initials) PLEASE SIGN'BACK OrAPPLICATION FORM 11 /30/00 clpenniLdoc BUILDING OWNER OR AUTHORIZED A T: Signature: Date: /......3.....e, 3 Print name: - (5; *1-1—,- ! Pher��/' 7 �,,,t ty �.� 64 ,, O�(p / I TT ,Fax i `� 7 492 Address ► 9G City/State/Zip- / r7 r• . APPLICATI(" MUST BE SUBMITTED WITH TH *LLOWING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN > BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale .2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing/grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) Z 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved E_.- Z 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use CL 2 only) 11. Location and gross floor area of existing structure with dimensions and setback U O 12. Lowest finished floor elevation (if in flood control zone) (.A 0 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H -9). J = 4-- ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled u_ W O ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. Q ❑ ❑ Vicinity Map showing location of site = • d I— 1 El 0 I Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack Z I— layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of W O Lii rack. Structural calculations are required for rack storage eight feet and over. 2 ❑ in Indicate proposed construction of tenant space or addition and walls being demolished U ❑ ❑ F- Construction details L0 W =U ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water 1 = supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed Z sprinkler system design criteria as identified by the Fire Department. U (n 2 ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. Z ~ ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 999 Third Avenue, Suite 700, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal l HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 11/30/00 clperniil. dric .12lAC.{,13'44:: - :'. 6i TRANSACTION LIST: ACCOUNT ITEM LIST: doc: Receipt Ci'y of Tukwila Current Pmts 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0223000060 Permit Number: D03-003 Address: 116 ANDOVER PK E TUKW Status: PENDING Suite No: Applied Date: 01/03/2003 Applicant: PITNEY BOWES Issue Date: Receipt No.: R03 -00005 Payment Amount: 1,175.14 Initials: KAS Payment Date: 01/03/2003 01:46 PM User ID: 1684 Balance: $0.00 Payee: MY -LAN CO., INC Amount Payment Check 4550 1,175.14 BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE RECEIPT Type Method Description Description Account Code 000/322.100 000/345.830 000/386.904 883.50 287.14 4.50 Total: 1,175.14 4043 01/06 9710 TOTAL 1175.14 Printed: 01 -03 -2003 .,..uL...w.. .,I..i.: riS .., •, i. ti. ..: k'J,t iL,wrr.. x....'A.S..u..:Jiir: , iI.:.1�e.. .:..�1 IJ...:s...J...:.::J..i.3: a..,F, Pr Act: ‘ isie 0(E 5 Type of Inspection: Address: I 1 1 (0 Atv&vvea N Date Called: -7- 2 2 , — 0 3 Special Instructions: Date Wanted: a.m. p.m. Requester: C'T ter Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 PERMIT NO. (206)431-3670 Approved per applicable codes. fJ Corrections required prior to approval. COMMENTS: Ins • ector: )64. 7.00 REINSPECTItN FEE REQUIR . Prior to inspection, fee must be Id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. RTn No.: Date: 7-2-3-03 Date: COMMENTS: > k— t vSv4 t.._. 1—e --c-✓ r 2 c5ti`^ ? 7- S ve.--t e c9 - 1-22_ —Q 2, . c C (,A t _J- lf.s c. F . 0 T ■ o"..,,, C-Pe■1 A I ` P 0' Li ion..1 0 k.d ,- f L, — va p p eve& Date Wanted: — Z3 -0'3 a.m. p.m. Requester: Phone No: -3 Go - G.G _ci 44 1 Pr eFt: 4) . +NEI o) > Type of Inspection: i , c_ Address: A 1IC∎ r.10■°v" Rz 9 Date Called: - 7-- z - 3 - C3 Special Instructions: Date Wanted: — Z3 -0'3 a.m. p.m. Requester: Phone No: -3 Go - G.G _ci 44 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. pector: Date: 1— 2 - 3 --° 3 47.00 REINSPE ON FEE REQUIRE - 1. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: Type of lnspecti Address: ►I� rl/l� ►1p P 6 Da te Called: 01 /PI 103 Special Instructions: �� I )5 ml,'.. � C' I' ' S 19 f(' � ,.,�� �l s,C _ i .—e r't C • ,r-,y ... ,.-,✓. . 4- Requester: 4 7i L Mi/er'i B CA_ 0 Lam.. r ldV I _ Probe Type of lnspecti Address: ►I� rl/l� ►1p P 6 Da te Called: 01 /PI 103 Special Instructions: �� I )5 ml,'.. � C' I' ' S 19 f(' � ,.,�� �l s,C _ Date Wanted: o 7/ 103 a m. . .fn' Requester: 4 7i L Mi/er'i Phone No:. a 9 y CS r INSPECTION RECORD Retain a copy with permit NO. PERMIT CITY. OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206 431 -3670 ved per applicable codes. 3‘..° 4‘4°- Corrections required prior to approval. spector: / $47.00 REINSPECT! N FEE REQUIRED. p rior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ceipt No.: Date: 7 » z2 /o' Date: JUL -22 -2003 17:46 MAYES TESTING ENGINEERS MAYES TESTING ENGINEERS, INC. July 22, 2003 City of Tukwila 6300 Southcenter Boulevard, #100 Tukwila, WA 98188 -8188 Attn.: Mr. James Dunaway Re: Pitney Bowes Tukwila 116 Andover Park East Tukwila, WA. MTE Project No. E3027 RECEIVED JUL 221003 BUILDING DEPARTMENT FINAL LETTER Permit # D Q� - 0,3 425 745 1737 P.02/02 Everett Office 917 -134th Street SW Suite A -1 Everan, 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S, Tacoma Way Suite E -2 Tacoma. WA 98499 ph 253.584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503281.7515 fax 503.281.7579 This is to advise you that special inspections are complete for the referenced project. The following inspections were required: 1) Epoxy - grouted anchor bolt installation Special inspections were performed for the following activities and copies of reports have been sent to you. 1) Epoxy- grouted anchor bolt installation All work inspected conformed to City of Tukwila approved plans, specifications, and related codes and/or verbal or written instructions from the Engineer of Record. Sincerely, MAYES TESTING ENGINEERS, INC. ichael . Dolder, P.E. 0 ce President TOTAL P.02 • z ~ J U 00 cn W= r ` w J co a = w z �. � w ~ .D o U • O P— 0)- w w , o. z w U= O z • JUL -22 -2003 17:46 MAYES TESTING ENGINEERS MAYES 17ISnNG ENGINEERS, INC. FaX To: Mr. James Dunaway Fa= 206-031-3665 Phone: 2064314674 Re: Special Inspections Final Acceptance Letter Pitney Bowes — Tukwila Permit; 003-003 Mr. Dunaway, Originals to follow via regular mail. Respectfully Subm' , ark A. G - usha, P.E. ayes Testing Engineers, Inc. CC: • 4 Franc Mark A. Galusha, P.E. Paces: 1+ cover Date: 7 -22-03 425 745 1737 P.01/02 Everett Office 917 -134th Street SW Suite A-1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Q Urgent XXXFor Review ❑ Please Comment ❑ Romp Reply CI Please Recycle Please find attached, a copy of our Final Acceptance Letter for Special Inspections performed for the above subject project. Please contact me at our office with any questions or concerns. z 1 Z c w c G U 0 C o CO ILI J • w w 0 LL U1 = I - w z � I- 0 z !— w Lu 2o 0 0 co • 0 F- wW 9 - - O ..z O — 0 z MAYES TESTING ENGINEERS, INC. July 22, 2003 City of Tukwila 6300 Southcenter Boulevard, #100 Tukwila, WA 98188 -8188 Attn.: Mr. James Dunaway Re: Pitney Bowes Tukwila 116 Andover Park East Tukwila, WA. MTE Project No. E3027 1) Epoxy - grouted anchor bolt installation 1) Epoxy- grouted anchor bolt installation chael . Dolder, P.E. ce President RECEIVED IJUL' 2 4 2003i COMMUNITY DEVELOPMENT FINAL LETTER Peumit # D03 -003 Everett Office 917.134th Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 This is to advise you that special inspections are complete for the referenced project. The following inspections were required: Special inspections were performed for the following activities and copies of reports have been sent to you. All work inspected conformed to City of Tukwila approved plans, specifications, and related codes and /or verbal or written instructions from the Engineer of Record. Sincerely, MAYES TESTING ENGINEERS, INC. P . row' 5.p z 4— Z1 -J U U0 LU • J1— u. w J u. a C3r � • z I I— 0 Z I- •w U � 0 Ni 01`1 w , U i 0 • t Z 0 1— •z July 8, 2003 Mr. Jay Mylan My -Lan Co., Inc. Woodinville, WA 98072 RE: Request for Extension — Permit No. D03 -003 Pitney Bowes —116 Andover Park East Dear Jay: This letter is in response to your written request for an extension to Permit No. D03 -003. Since the work is completed, as noted in your letter of July 2, 2003, the City of Tukwila Building Division will extend your permit five (5) business days from receipt of this letter (approximately July 16, 2003), in order for you to call and receive final inspection. Please be advised that this will be the only extension granted for this project and no further notice will be given prior to the expiration date. A new permit and associated fees will be required after the above -noted expiration date. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely; "� Ro ' ert Benedic Building Official RB /sks File: Permit No. D03 -003 city of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 Co P.O. Box 912 Wbocirnnle, WA 99072 (360)66856 Fax (360)668 -1996 July 2, 2003 City of Tukwila Dept. of Community Development 6300 Southcenter Blvd. Ste. 100 Tukwila, WA 98188 RE: Permit Application No. D03 -003/ 116 Andover Park East Attn: Stefania Spencer I have received your letter concerning our permit application. I am requesting an extension to complete the finalization of the above project. The work is completed but we still need to make arrangements for a field site inspection by your department in order to complete the process sufficiently. Please advise as to if this will be granted. Sincerely, zi Jay R. Mylan (evi ww dize.eite;ter 16 - 7- g -2Cza Co z T w u `S �` -J C.) Uo U D J • H w 0 ga U � d = w z � I- o Z F- LU 2 0 o - 0 F- w w � U; I L - O w U N 0 z June 6, 2003 Jay Mylan 12311 238th Street SE Snohomish, WA 98296 RE: Permit Application No. D03 -003 116 Andover Park East Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Sincerely, Xc: Permit File No. 003 -003 Bob Benedicto, Building Official Ciz of Tukwila Department of Community Development Steve Lancaster, Director • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. Steven M. Mullet, Mayor This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to July 13, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Stefanie Spencer Permit Technician 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431.3670 • Fax: 206 - 431 -3665 WeiAmcgorpftesimgarorstwaixsttsi MAYES TESTING ENGINEERS, INC. MTE No.: Project: Address: Permit #: Owner: Architect: Engineer: Contractor: Page 1 Date: Weather: Inspection: REVIEWED BY: cc:Bldg Dept -City of E3027 PITNEY BOWES - TUKWILA 6 ver Park East, Tukwila, WA D03.003 City of Tukwila) Pitney Bowes Coughlin Porter Lundeen My -Lan Co., Inc. 2/3/03 Rain Epoxy of threaded rod Observed My -Lan drilling 11/16" holes, cleaning and blowing out holes for seismic bracing of exterior walls of building. Next, My -Lan epoxied -in %" threaded rods for an embedment depth of 4W, using Simpson Strong Tie acrylic -based anchoring adhesive, as per plan page S3.1, details 4, 3, 5, 9, 10 and 15, on the south, 2 "d floor, turnbuckles on east addition; and north wall, 2 floor. To the best of our knowledge, all items inspected today are in conformance with approved plans and specifications. J/ ark ` • Gtusha, P.E. wile, Jay Mylan -My -Lan Co., Inc. RECEWED FEB 1 4 2003 COMMUNITY DEVELOPMENT INSPECTOR: Clyde Anderson Everett Office 917 -134th Street SW Suite A -i Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 MAYES TESTING ENGINEERS, INC. MTE No.: Project: Address: Permit #: Owner: Architect: Engineer: Contractor: Page 1 Date: Weather: Inspection: Observed My -Lan drilling 11/16" holes, cleaning and blowing out holes for seismic bracing of exterior walls of building. Next, My -Lan epoxied -in %" threaded rods for an embedment depth of 4W, using Simpson Strong Tie acrylic -based anchoring adhesive, as per plan page S3.1, details 4, 3, 5, 9, 10 and 15, on the south, 2 floor, turnbuckles on east addition; and north wall, 2 floor. To the best of our knowledge, all items inspected today are in conformance with approved plans and specifications. REVIEWED BY: cc:Bldg Dept -City of E3027 PITNEY BOWES - TUKWILA er Park East, Tukwila, WA ity of Tukwila) itney Bowes Coughlin Porter Lundeen My -Lan Co., Inc. 213/03 Rain Epoxy of threaded rod lusha, P.E. wile, Jay Mylan -My -Lan Co., Inc. RECEIVED FEB 1 0 2003 COMMUNITY DEVELOPMENT INSPECTOR: Clyde Anderson Everett Office 917 -134th Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 ACTIVITY NUMBER: D03 -003 PROJECT NAME: Pitney Bowes Seismic Upgrades SITE ADDRESS: 116 Andover Pk E ),Original Plan Submittal Response to Correction Letter # DATE: 01 -03 -03 Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: �,� tlwe 1-?).CC Building Division Publi orks DETERMINATION OF COMPLETENESS: (Tues., Thurs.) APPROVALS OR CORRECTIONS: Approved ❑ Notation: Documents/routing slip.doc 2.28 -02 0 COORD GUr Y PLAN REVIEW /ROUTING SLIP Approved with Conditions 50 1-1-o5 Fire Prevention Structural n 2& Planning Division Permit Coordinator DUE DATE: 01-07-03 Complete d Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg p Fire ❑ Ping ❑ PW (] Staff Initials: TUES/THURS ROUTING: Please Route Fvf Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: P .RM1T COORD COPY DUE DATE: 2-04 -03 El Not Approved (attach comments) ❑ REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: F(25.052 -000 (S /97) DEPARTMENT OF LABOR AND INDWRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL ) nl i j NTREGIST.:;$#: ;; :,., EXP. DATE CCQl f MXLi NCI009DC 02/25/2004 EFFECTIVE DATE Inc 03/03/2000 MY- LAN,COMPANY INC 12511 238TH ST SE SNOHOMISH'WA 98296 CITY OF' TUKWILA JAN - 3 2003 PERMIT CENTER t ae ' � No:s eie► - 5 �!%c "0.c GF::A: I . THIS STR'„ CT'JRF 90E5 `G" G NFOR4 TO PRESENT _NQ'^ -+4, AKE COVE REXIREMENTS. :- &C BEEN VOLUNTARIL RE '' CED :N ka,. RD A,NCE WITH CHA°'ER 3 OF =E ,N I =GRM 3L, I LD I N6 GORE AND :5 n: -: N "-E CURRENT P4a. ✓_ FOR THE FENGY .T I ON OF EXISTIN6 BU 1 LD: NE r OF T -. 5 .A6_ AND "''E OF COSETR- J I Oh . _x: ST : N5 STRLCURE :5 BEI' VOLUNTARILY FIEN6T4ENED. ALL Ex: 5T: N6 NALL OVT- OF -FLA E GO PS'NENT5 ARE E VA -J ATE✓ TJ CDV " MI T!- 'Qtr ,,NI FOR 3, I :DI N6 609E REO.; I RT5 EXC AS NOTED. I Yr et/DR.KnD GON40... ! reTH 4a' 'JN!PORN Bu'L✓ N6 C01 Fr -cI 'P (1.3 ) Y'� T Q7 = RID : 3.0 .'/.: =0.36 EN6INEER REGO6N I ZES T '-L.OM I N6 ' aq-1 UN I FORM 3UU I LD: N6 GODS PROVISIONS MAY NOT BE 4E7: A. 16S2.2 Rr :'.5 FOR SHA.._OM LANG i6<5 E. 1633.2.¢.1(5; M :N :MUM HOOD TH :O( = 2;' AT Si.1BPJ_ NS 2. CONTRACTOR SHALL VERIFY AL_ EXI5T:N6 DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO C mMENG I N6 A N Y H O R K . ALL D I M E N S I O N S OF EX:5T'. N6 CONSTRUCTION .r�.Jl'i'N ON THE DRAW( N65 ARE IN'ENDED AS G UIDELINES ONLY AND 4J5T BE VERIFIED. THE :XISTIN6 COND :TIONS 5HO N ON THE DRAWIN65 ARE BASED E I THE cc ON SITE OBS_ERVAT I ON , 'JR 161 NAL DRAM'.N65 OR HERE ASSUmED BASED ON EX°EOT ✓ CONDITIONS. IF HE EX . ST' N6 GOND'. T I ONS DO NOT OLOSELY 'SAT!,^ THE w ON5 SHOrs ON THE DRAW : N65 , OR IF THE EXISTING MATER:A -5 ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PR :OR TO COM`ENGIN6 ANY WORK. 3. GONTRA.TOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROGEDVRE5 REQUIRED TO PERFORM THE WORK. 4. CONTRACTOR - INITIATED GH.AN6E5 SHALL BE SUBMITTED IN WRITING TO THE STRJGTURAL EN6INEER FOR APPROVAL PR:OR 70 FABRICATION OR CON5TRXTION. GHAN6E5 SHOWN ON SHOP DRAYrIN65 ON'_" HIiL NOT SATISFY THIS REZ I REMENT. 5. DRAW :1x65 INDICATE 6c'NERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPEC I F I GALL I ND I GATED BUT ARE OF SIMILAR CHARACTER TO DETAILS S H0!'dr, S I "" I LAR DETA I S OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEh AND APPROVAL BY THE STRUCTURAL EN6I` R. 61✓SPEC'AL INSPECTION: EPDXY GROUTED INSTALLATIONS AND HOLDOWN INSTALLATION SHALL 'CBE SUPERVISED IN ACCORDANCE WITH SECTION '70' OF THE UBC AND THE PROJECT SPECIFICATIONS BY A QUALIFIED 7E-STIN6 A6ENCY APPROVED BY HE ENGINEER AND THE LOCAL JJRI5DIGTION. THE STRUCTURAL EN6INEER SHALL BE FURNISHED HIM COPIES OF ALL INSPEGTION REPORTS AND TEST RESULTS. DEMOLITION: I 1. DEMO 'TION. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. 5HORIN6 SHALL BE INSTALLED TO SUPPORT EXI5TIN6 CONSTRUGT:ON AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. DRILL :N6 SHAL:. NOT GUT EXiSTIN6 REINFORCING. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EX :STING FLOOR SYSTEMS TO 40 PSF. ANOHORAGE 8. EPDXY- GROUTED RODS OR REBAR '0 CONCRETE, SPECIFIED ON THE DRAWINGS SHALL BE GROUTED WITH '5ET EPDXY -TIE ADHIIIIVE' AS MANUFACTURED BY SIMPSON STRONG -TIE GOMPANY, INC. INSTAL IN STRICT ACCORDANCE WITH ICBO REPORT NO. 521q, INGLUDIN6 MINIMUM EMBEDMENT REQUIREMENTS. SUBSTITUTES PROPOSED BY CONTRACTOR SHALL BE SUB"":TTED FOR REVIEW WITH :CBo REPORTS INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES. IN ADDITION, FOR WIND OR SEI5MIG ,APPLICATIONS, SUBSTITUTIONS SHALL MEET ICBO ACCEPTANCE CRITERIA AC58. SPECIAL INSPECTION OF FOXY - GROUTED ANCHOR INSTALLATION :5 REQUIRED. HOLES IN CONCRETE MAY BE DRILLED BY GORIN6 OR ROTO- HAMMER UNLESS NOTED OTHERWISE. • UNDERCUT ANCHORS TO CONCRETE, SPECIFIED ON THE DRAWINGS SHALL BE,;.1P4. AI'VFACiURED BY COVERT OPEERATIO , INC.. INSTALL IN STRI.GT ACCORDANCE WITH IC50 REPORT NO. ER -4846. SUBSTITUTES PROPOSED BY CONTRACTOR SHALL BE SUBMITTED FOR REVIEW WITH IGBC REPORTS INDICATING EQUIVALENT OR GREATER GA°AC TIES. SPECIAL INSPECTION OF UNDERCUT ANCHOR 15 REQUIRED. REPAI 10. IF HOLE IN CONCRETE SHOULD COMPLETELY PENETRATE THE WALL, THE CONTRACTOR 15 RESPONSIBLE FOR FILLING AND PATCHING. II. T`"BER CONNECTORS GALLED OUT BY LETTERS AND NUMBERS SHALL BE 'STRONG -TIE' BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. G -2002. EQUIVALENT DEVICES BY OTHER MANUFAGTURER5 MAY BE SUBSTITUTED, PROVIDED THEY HAVE IGBO APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES AND ARE SUBMITTED TO THE EN6:"ZER FOR APPROVAL. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN AGGORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. WHERE CONNECTOR 5)5 CONNECT TWO MEMBERS, CENTER STRAP ON JOINT AND PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER, WITH EQUAL NUMBER AND SIZE OF FASTENERS IN EACH MEMBER. AL- BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A301. PROVIDE HASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LA6 SGREHS BEARING ON WOOD. ALL NAILS SHALL BE COMMON UNLESS OTHERWISE NOTED. ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. ALL JOISTS AND MULTIPLE JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS W :T- 'U' SERIES JOIST HANGERS, UNLESS OTHERWISE NOTED. 12 ALL NEW LUMBER TO BE DOU6 -FIR 40.2. 13. ALL BOLTS BEARING ON WOOL TO HAVE STANDARD -GUT WASHERS UNDER HEAD AND BOLT. ! understand that the Plan Check approvals are subject to errors and onves +ors and approval Of plans does not authorize the vij at!on of any adopted code or ordinance. Rea .Ct of con- tractors copy of approved plans acknowledoed By Dat z _ /"2 .( Permit No. 53.' DETAILS FILE COPY SEPARATE PERMIT REQUIRED FOR: We MECHANICAL m ELECTRICAL pig P LAMBING rior GAS PIPING CITY OF TUK VILA BUILDING DIVISICN Ivo c REvisholvs THE sc o tl ir ci o e F s vv et . , ,t . i. eF i44'17,-. w+r w4 q 8j�/ I . + F T C SHEET INDEX: 51.1 6ENERAL 5TRUGTURAL NOTES S2.' SECOND FLOOR FRAMING PLAN ROOF FRAMING PLAN 9 ;7- ,3 RECEIVED CITY OF TUKWILA JAN 3 2003 PERMIT CENTER Doi 00 1 — z:3* CI 77.3 7 I CU i... V L) 0 ▪ s cRi V CJ) cn () ;;;O II■N O CTS CCa irz_. SHEET Tr L SHEFT NUMBER DATE RENSION GENERAL STRUCTURAL NOTES 5020316 -C3 JOB NO KLM DRAWN TR N KWM DFSi(NED 11-'3-C2 DA-F. S1.1 z 0 a C �•o O AA d .0 .D O N h 0 &‘L. z w LJ z V z W U 0 z Q O • — oc � w U � ` N co (3 LAJ Da z d< J N • W W (p J z Z 1- O I-- U I\ Q - w < N to ILI L.LJ 0 V • HDBA, TYP. 4./S51 e:\ I ir 1 4./53. r EX(3)2x,E EX. 446 STRUT , EX. (2) 2x16 20 f EX2xl6 ®i6oc' , EX 2x16 ®16oc EX. TIE EX 4x16 STRUT SCALE: 1 4"::I'-0" i EX TIE 1:7-- 1100 -0' 20-0' ='./53 iv-178A, EX 2xI6 ® 16 oc EX. (2) 2x16 EX (2) 2x16 EX. (2) 2x6 EX. 4x16 STRUT EX. PULL HT - GUR ML f / TIE EX. 4x16 57RUT SECOND FLOOR FRAMING PLAN 20-0' 2C-0 EX2xl6 ®Iboc EX. (2) 2x16 v W kb w z w < 5/53! HD8A 613, EX. TIE EX. 4x16 STRUT Er. (2) 246 ,46( • I) f 1 I J W u • In N u 4 O N 4/53.1 HDSA, TYF. 9 1 N O PLAN NOTES: I. ALL DIMENSIONS OF EXISTING STRUCTURE ARE BASED ON THE ORIGINAL CONSTRUGT!ON DRAWINGS AND ARE SHOWN FOR IN'ORMATION ONLY. CONTRACTOR TO FIELD MEASURE AND VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING ANY WORK. 2. EX. FLOOR SHEATHING 3 4" PLYWOOD 1 ® 2I "oc BOUNDARY NAILING, IOd ® 4 "oc EDGE NAILING, 10d ®I2 "oc FIELD NAILING. CITY OF TU W ILA JAN - 3 2003 PERMIT CENTER 1:)4U3 - 00.3 C • . s✓ a •o 43 0 frt en en 00 N a La- O O w ✓ � 1 — , I— 0, w Q cC L w Z J Q — w • (n • CI) . 7-.3 E ...I's ci) twp-c-) ca...%-.-- Q 1 o..- lii --. c„, ._ ILI ci.) = c.) . ...: 0 . 0, CLS W �� L CL 6- Z 0 te) Q VD *4 p > otos C =I CZ Co ta.) CL- Immuum NO. DATE REVISION SHEET TITLE SECOND FLOOR FRAMING PLAN 5020376 - 03 :OS NO KLN r A'NN TRW 1.4 NM DER't,NED II -13 -02 DATE: SCALE: ie " =I '_0" SHEET NUMBER S 2.1 \()) / EX. 240 t§ 24 oc I / HI r 2-0' i_) EX 6x4(12 Dr *I r I • _,..• a.., J Ex 644 yF s. EX. 6x14 OF #1 r rt I I I 15 t 4 - f I ) I � s 10- ' , A I EX. 24C ® 24 "oc EX. 2x10 ® 24 oc A li EX. 6x14 DF x1 ROOF FRAMING PLAN SCALE: 100* -o 20-0' H h EX. 6x14DF h , EX. (2) 2x10 20'-0' EX 644 DP NI EX 6.44 OF If EX. 644 DP II 1* It EX. 6x!4 DF If EX. 2x10 ® 24'oc EX. 2x10 ® 24oc I, I 9.53. inD5A TYP. Y - T 1 20 -0" < 0/S3.1 JI r+DSA, 'Y EX 644 (Dl DF +�1 1/ 7x/53.; )/ / I ./I1 0 J , A 5/53.1 HDBA, TYP. Li 1 n 4 I N U I FLAN NOTES: I. ALL DIMENSIONS CF EXISTING STRUCTURE ARE BASED ON THE ORIGINAL CONSTRUCTION DRAWINGS AND ARE SHOWN FOR INFORMATION ONLY. CONTRACTOR TO FIELD MEASURE AND VERIFY EXISTING CONDITIONS PRIOR TO COMMFNG NG ANY WORK. 2. EX. ROOF SHEATh1`46 PLYYV00D NV 10d 9 4 "oc BOUNDARY NAILING, 10d 9 b "oc EDGE NAILING, 10d i2 "oc FIELD NAILING. RECEIVED CITv OF TUKWILA JAN - 3 i003 PERMIT CENTEP A cn CU IT ND. DATE RFVISKM ME` TITOE ROOF FRAMING PLAN 5020376 -03 Joe NO KLM DRAWN- TRW, KWM DESIGNED: II -13-02 DATE SCALE: Ii "_ I I- SHEET FR 10 (j6) S2.2 Z 0 f— 0 " O a 0 00 0 & Z W 0 z J Q O n — cTD (-9 w C's Z < J • Vf N LLJ W 0 U _1 < Q N V) • HOEDOWN II WCOD CONNECTION WALL ANCHOR ' HDSA 1 (3) VO (EMBED 4 ''2') h �1 I6 12 n Ex .` G - rn 6 • 13 FOR CALL-0 CD"A'MO'4 SEE DE'.A: L 5/53.: Fr; to 8' -Vac PER PLAN d 20/53.1 EX. JOISTS 2x10 x 2'-6' EA. SIDE GLUE i SCREW Y'U (6) SIMPSON 505 EA. PLATE, (12) SCREWS TOTAL 'cam ,1 . 0 1 "x10'x0' -10' W/ (4) N." EPDXY GROUTED THREADED RODS. EMBED 416' NOTE: INSTALL AT ELEVATION tb" FROM SOT. OF JOISTS. /IV ° 1 600' 6005 14 solo lci EX ROOF SH_A - b e ( tk `_ L , d /Jr Lj� EX. -.c - -Vat PER PLAN t 2CiSS 0 I6' -O'bc PER - -,, !'LAN 4 20/53. / FOR CALL -OUTS IN COMMON SEE DETAIL 5/53.1 3 4'0 EPDXY ANCHOR EX. CONCRETE WALL NOTE: EX CO C WAL_ -- d co `!t R o w JAN g 2.003 I1> lc lid • i r r0 S -O'oc PER FLAN 3 20/53.1 LEX. J015T5 2x10 x 2--h" EA. E:DE GLUE S SCREYY wr (6) S1M°SON SD5 .r3" EA. °LATE, ; EGREWS TOTAL HD to S' -0"oc PER PLAN d 2C/53.1 0 0 WALL ANCHOR MAY BE EPDXY GROUTED OR UNDERCUT PER GENERAL STRUCTURAL NOTES. 6C: 6005 io -2x'0 x 2'-6" EA. 51DE GLUE 4 SCREW W/ (6) SIMPSON 505 iax3" EA. °LATE, (12) SCREWS TOTAL RECEIVED CITY OF TUKWILA JAN - 3 2003 PERMIT CENTER 6007 15 -1)03 5 004 O C1) - — C3 m rt5 (I) beJD- (-) C) • I NO. DATE 'REVISION c*EET TI *t.E 5020316 -03 JOB NO KLM DRAWN: TRW OM DESIGNED. 11 -13 -02 DATE: SCALE: 3 /4 " =1' -0" SHEET NUMBER DETAILS S3.1 4)o I No O In rn "h 1 f 0 0 lV N 0 0 rn W 5 f-- W W ac w (• 0