Loading...
HomeMy WebLinkAboutPermit D03-005 - DIEBOLD - STORAGE RACKSD03 -005 Diebold, Inc. 3415 So. 116th1 St. Parcel No.: 1023049043 Address: 3415 S 116 ST TUKW Suite No: City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Number: D03 -005 1 z Issue Date: 01/16/2003 �re Permit Expires On: 07/15/2003 6 D JU 00 Tenant: co 0 Name: DIEBOLD INC w = Address: 3415 S 116 ST, TUKWILA WA N 1- WO Owner: 2 Name: AMB INSTITUTIONAL ALLIANCE Phone: Address: CO MCELROY GEORGE & ASSOC, 3131 S VAUGHN WAY STE 301 u- < CO a Contact Person: f _ Name: MIKE SORENSON Phone: 206 - 818 -4488 ? (- Address: 1100 SW 7 ST, RENTON WA Z O . uu Contractor: U 0 Name: NORTH WEST HANDLING SYSTEMS INC Phone: 206 255 -0500 Address: 1100 S.W. 7TH STEET, RENTON, WA g 1-- Contractor License No: NORTHWH275JF Expiration Date: 10/09/2003 = w u_ S .. W Z U= O H DESCRIPTION OF WORK: REASSEMBLE & ANCHOR 26 BAYS OF RACK DEVELOPMENT PERMIT Value of Construction: $0.00 Fees Collected: $93.60 Type of Fire Protection: SPRINKLER Uniform Building Code Edition: 1997 Type of Construction: Occupancy per UBC: Public Works Activities: Curb Cut/Access /Sidewalk/CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N Water Meter: Channelization / Striping: ** Continued Next Page ** doc: Devperm D03 -005 Printed: 01 -16 -2003 Z Permit Center Authorized Signature: Signature: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Print Name: KoltAf,) ,d7t d' 0,1 Ste..--? D03 -005 '~ w J U. 00 N 0. uJ =` J I— Date: 7 /K /� O. u_? • = d. W Z = f-. 1— O Z I— U � O N. CI 1— UJ I H-• — O: W Z - I O Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 01 -16 -2003 • z i:sarr. a� Z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1023049043 Address: 3415 S 116 ST TUKW Suite No: Tenant: DIEBOLD INC PERMIT CONDITIONS Permit Number: D03 -005 Status: ISSUED Applied Date: 01/07/2003 Issue Date: 01/16/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 4: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 5: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 6: ** *FIRE DEPARTMENT CONDITIONS * ** 7: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 8: Maintain fire extinguisher coverage throughout. 9: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 10: To use any building or portion thereof exceeding 500 square feet for the storage of high -piled combustible stock. A floor plan showing the dimensions and location of the stockpiles and aisles shall be submitted with applications for such permits. (UFC 8101) 11: In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 13) 12: High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible materials on pallets or in racks more than 12 feet in height. For certain special- hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (UFC article 2, sec. 209 -H) 13: Maintain minimum 6" longitudinal flue space between back to back racks. (NFPA 13) 14: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinklers at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 15: Racks designed for high -piled storage must comply with section 2207 of the Uniform Building Code. Please contact the Tukwila Building Department for details pertaining to design and installation standards. 16: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 17: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 18: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws doc: Conditions D03 -005 Printed: 01 -16 -2003 c�laiF3ovi;+tS:haaiAl,�n. regulating construction or the performance of work. Signature: Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 ;k.e_ 7' C�vtS� D03 -005 Date: ( / (C.) Printed: 01 -16 -2003 Project Name/Tenant: Value of. Construction: Proposed use: ❑ Retail ❑ Restaurant ❑ Multi - family 'V. Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Site Address: .4, City State /Zip: 3 i s .5, I( .`- sy #/ 9 Secil(k CtJA 1 / (),‘? Tax Parcel Number: Property Owner: Phone: Street Address: City State /Zip: Fax #: Contractor: y 1 Li ��5� /74 o r Phone: Street Address; City S tate /Zip: //O 0 G_ 21 9fos`s Fax ft: . mss _ 2_ _ i 4 Architect: 7 ,. .// Phone: Street Address: City State /Zip: Fax #: Engineer: - Phone: 8 I8- 4' 57 � Pe %?ate Do 1 t /�,el' (v - Street Address: City State /Zip: 7k.6 L, c ir- e5ce44 4vt- o4Y ��n C -4 g170 e Fax #: 91 - y 7 - 3d 0.3 , Contact Person: . , /�,) G- So remsv�I ,C 6 e/ f-/ -5 Phone: '/ �/ ;- > 20 6 3 IS' `� Yt�O Street Address: City State /Zip: //G40 (iv 7' 5/. i d1 (/p /Pd 5 Fax #: V2 S Pa-e..65/6 Description of work to be done :. / r - / / kap d >< �� c� C s e w ��y;,t 2 4 Ss2� /O� , anelc2c- (6 ) dc-la; is Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family a Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi - family 'V. Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes in no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? 6, yes ❑ no Existing fire protection features: • •'% sprinklers 01 automatic fire alarm ❑ none El other. (specify) Building Square Feet: Od O existing Area of Construction: (sq. ft.) g 5-0 v Will there be storage of flammable /combustible hazardous material in the building? El yes 111 no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUK' /ILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. Dale application accepted: i 'x-03 CTPERMIT.DOC 1 /29/97 APPLICANT REQUEST FOR. PUBLIC WORKS SITE /CIVIL PLAN REVIEW OF THE.FQLLOWIN (Additional reviews may be determined by the Public Works Department) Date application expires: '��._r___- `:+:::::�' "'; ���c,"+ rs7L�a4.; t¢' g! w."..; nctl'j Sfi�S}` Yk4�.r nf,!'• lwff ?!tc:`;n�•Ci, >1q,:�;n�,�_t$ El Channelization /Striping ❑ Curb cut /Access /Sidewalk El Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. El Landscape Irrigation El Sanitary Side Sewer #: El Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only El Water Meter /Permanent # Size(s): El Water Meter Temp # Size(s): Est. quantity: gal El Miscellaneous CI Flood Control Zone ❑ i Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Applicat! n taken by: (initials) PLEASE SIGN BACK OF APPLICATION FORM • BUILDING OWNER OR AUT IZED AGENT: / S- ..25 Date: / /‘( -w ( L. 3 �oZ,, ‘cw Signature: f��S Print name: i ''i4.6 Address/4)0 ,Su/ 7 ‘5' . an ip j,OSS ALL COMMERCIAL/MULTI-F Y TENANT IMPROVEMENT /AL TION PERMIT APPLICATIONS MU EE SUBMITTED WITH THE POLL- IN : ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ 1111 Complete Legal Description ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ • Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required fo' Public Works Review (Form H- 9). ❑ 49 Floor plan: show location of tenant space with proposed use of each room labeled ❑ . Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ '. Vicinity Map showing location of site ❑ `t Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ Indicate proposed construction of tenant space or addition and walls being demolished .45 ❑ le Construction details Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. SEPA Checklist - if intensification of use (check with Planning Department for thresholds). Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect /engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM A UTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC V29/97 "'1st +*'wSw:s9: 'A.i ':L TRANSACTION LIST: ACCOUNT ITEM LIST: doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 I Tukwila, WA 98188 / (206) 431 -3670 z RECEIPT re m . Parcel No.: 1023049043 Permit Number: D03-005 6 Address: 3415 S 116 ST TUKW Status: APPROVED U 0 Suite No: Applied Date: 01/07/2003 rn Applicant: DIEBOLD INC Issue Date: w _ H Nu_ w O Receipt No.: R03 -00050 Payment Amount: 58.50 2 J Initials: KAS Payment Date: 01/16/2003 11:57 AM u. User ID: 1684 Balance: $0.00 = d . H = Z i- Payee: NORTHWEST HANDLING w O; D ui O - Type Method Description Amount CI E - Ill W Payment Check 179483 58.50 F' U. g .. Z w 0 I' O Description Account Code Current Pmts Z BUILDING - NONRES STATE BUILDING SURCHARGE 000/322.100 000/386.904 54.00 4.50 Total: 58.50 00 01/16 ':)716 TOTAL 53.50 Printed: 01 -16 -2003 • RECEIPT - W it 2 Parcel No.: 1023049043 Permit Number: D03-005 Address: 3415 S 116 ST TUKW Status: PENDING U O . Suite No: Applied Date: 01/07/2003 u) ❑ Applicant: DIEBOLD INC Issue Date: w = —I,— W 0 Receipt No.: R03 -00016 Payment Amount: 35.10 g Initials: KAS Payment Date: 01/07/2003 01:45 PM ur User ID: 1684 Balance: $58.50 = (3 F- W Z !— Payee: MICHAEL SORENSON Z O U� Type Method Description Amount p H W Payment Check 5060 35.10 "ID H I= L I 0 .. Z W U Description Account Code Current Pmts Z ~ TRANSACTION LIST: ACCOUNT ITEM LIST: doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PLAN CHECK — NONRES 000/345.830 35.10 Total: 35.10 42.4 01/09 9716 TOTAL :k5 -i rk Printed: 01 -07 -2003 Project: Di p -Zvi( Type of Inspecti Q. ,te..„ Address: 3� / 5 � (IP � Date Called: I 7 Special Instructions: Date Wanted: l //-- / k 3 .7:1 Reques er: // b Li . a _ cifc „Sp a/A7f-eA 1 Pho a No: INSP CTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 proved per applicable codes. COMMENTS: No d ei dr?, ) INSPECTION RECORD Retain a copy with permit — re; -/e>-7 3 poi -06 (206)431 -3670 El Corrections required prior to approval. 0 $47.00 REINSPECTIO FEE R QUIRED: Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Proiect Name LICL H..Address I. /e)e— ,Retaincurrent,inspection schedule. ../// Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: , 3 Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: , "?■/' AllthOlized Signature FINALAPP.FRM City of Tukwila Fire Department Thomas P Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Rev. 2/19/98 , lleadquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 Steven M. Mullet, Mayor Permit No. Da? —C2C25--- Date Suite # /95' T.F.D. Form F.P. 85 BY G. OHANIAN DATE 1-2-03 SUBJECT. STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: DIEBOLD, INC. 341 5 SO. 1 1 6th St. #1 49 SEATTLE, WA. PER UBC 1997 STORAGE RACKS CAPACITY: 3500 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD 7488 R hK DESIGN & ENGINEERIT H CO. 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL:(818)957 -2980 FAX:(818)957 -8603 tcrr r ( PY if kw 10 sovi 30 15 "ti skau EXPIRES 12 -26 -03 • SHEET NO. 1 Joe No RD -7488 RECEIVED CITY OF TUKWILA JAN - 7 2003 PERMIT CENTER DO3 ooS By G. OHANIAN DATE 1-03-03 SUBJECT 496 BEAM 3500 # / LEVEL + 25% IMPACT LOAD 2000 # / BEAM I =2.8 S =1.2 F Y= 50 KSI. SEISMIC DESIGN V _ 2 5xCaxl x W Rx1.4 1 =1 R =5.6 R =4.4 Na =1 Ca =.36 W= D.L. +L.L. WORKING STRESS LOAD PER COLUMN P= 2x3.5 _3.5 K 2 W =.1 + 3.5 =3.6 K 0.L. L.L. V _ 2.5x.36x3.6 = LONGIT. 5.6x1.4 DIR. V _ 2.5x.35x3.6 = TRANS. 4.4x1.4 DIR. 120" OR 144" FRONT VIEW RA' ' DESIGN & ENGINEERIN' 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL :(818)957 -2980 FAX:(818)957 -8603 i UBC 1997 SEC. 2222 LONGIT. DIR. (MOM. CONN.) TRANSV. DIR. (BRACED) .41 K .52 t 0 0 to N d I 1 , 1 3 /4" i 44" SIDE VIEW 1 =0.07" l 2 3/4" i LONGIT. SEISMIC .41 21 K 2 M= 144 "x2 K - 36 "K 8 S 36 "K = 1.2 30 A _ 5xWxL = 7:: < 144 = 8 " 384x1 xE 180 6 SHEET NO. 2 JOB NO. RD -7488 1 "K 6 K 1 1 BY„ G. OHANIAN DATE 1-03 -03 SUBJECT. COLUMN ANALYSIS ,n 5/8" � a X - - - X t =.09" COMBINED STRESS RATIO P + Max- 10 + 1 - 1 -= .6 <1.33 a BASE PLATE F Y= 50 KSI A =.5 S =.43 r =1.2 r =1. 11 K—(3.61( " ANCH. TENSION = x3 = 1 K ANCHOR SHEAR = 4 t _ 21 2 (2) -1/2 "o WEDGE TYPE ANCHORS ICBO #4627, OR #1372. (NO INSPECTION REQ'D) DESIGNED FOR 1/2 STRESS RACK COLUMNS DESIGNED SUCH THAT IF THE FRONT COL. IS DAMAGED THE REAR COL. HAS EXTRA CAPACITY TO SUPPORT THE FULL LOAD OF THAT BAY, (SEC. 2222 -5) MOMENT AT BEAM CONNECTION M1 = 11 2 +6 = 9 "K RAC DESIGN & ENGINEERINC 20. 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL:(818)957 -2980 FAX:(818)957 -8603 KI = 80 = 67 rx 1.2 KI _ 54 _ r 1.1 "K Max =S .Fb =13 7/16 "0 RIVET A = .095 Fy = 79 KSI Va = .095x79x.4 = 3.0 TYP 3.6 SHEET NO. 3 JOB NO. RD -7488 Fe = K � E 64 r F " =F 4F )= 40 KSI e P =F xA = 20 K Pn K P° — 1.92 = 10 7/16 "01 RIVET ASTM A354 -79 2 PIN CONNECTOR 7 3/4 "x5 "x3/8" BASE PLATE TH'K =3/16" Ma = 3.0 K .33 = 16 "K CONN. .,.»...+ o.✓ a... l..✓✓.. Y.... .w..J.r..i..aw..v'wSev4y+.:i.i: Wt.,..:.ui. rv... ...w • By OHANIAN DATE 1-02 -03 SUBJECT. TRANSVERSE SEISMIC (OVERTURNING) TOP LEVEL LOADED ONLY M .52 x120 "x.5x1.15 =70 M = .26 x120 " =62 COL. COL. MR = 3.6 " = 158 K LOAD TO DIAGONAL P = .52 x 42 = 1.4 R/ _L ❑ COL. BOTH SIDES TYP. 1/8 X 1.5 KS' F =50 KSI 1 1 / A =.31 F = 11.2 \ —� p ! f = i_ x ID r .48 \ P = 3.5 K -- Q =.74 1 =.07" f L= 56" SEC. A -A � ' . ❑ 0 CHECK WELDS 1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL) 3x.125x.707x70x.3= 5.7 K CHECK SLAB 3600 5" CONCRETE SLAB 2000 PSI. CONC. 1000 PSF. SOIL RAC' DESIGN & ENGINEERING CO. 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL:(818)957 -2980 FAX:(818)957 -8603 MR = 1.9 K x44' =84 " NO UPLIFT 3600 = 3.6 1000 N/ 519 =23" S= 12x5 2 =50 6 1> TYP 1 / 8 r1.5 ) awe SEC. B -8 3.6x144 =519 0" 2 "# M= (� 2 ) x 1000x 2 x12 = 2042 2042 — 41 < 1.6 2000 =72 50 SHEET NO. 4 JOB NO. RD -7488 June 6, 2003 Mike Sorenson 1100 SW 7th Street Renton, WA 98055 Dear Permit Holder: City of Tukwila Department of Community Development Steve Lancaster, Director RE: Permit Application No. D03 -005 3315 South 116th Street In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to July 20, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefanie Spencer Permit Technician Xc: Permit File No. D03 -005 Bob Benedicto, Building Official Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206-431-3665 ACTIVITY NUMBER: D03 -005 DATE: 01 -07 -03 PROJECT NAME: Diebold Inc. - Racks SITE ADDRESS: 3415 S 116 St., #149 X. Original Plan Submittal Response to Correction Letter # Revision # After Permit Is Issued Response to Incomplete Letter # DEPARTMENTS: l Building Division Public Works Complete TUES/THURS ROUTING: Please Route C APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2.28.02 PLAN REVIEW /ROUTING SLIP h�IZ fku) Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n n n Permit Coordinator Planning Division DUE DATE: 01-09-03 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: V DUE DATE: 2 -06-03 Approved C Approved with Conditions Not Approved (attach comments) C Notation: REVIEWER'S INITIALS: DA TE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: f(,25. 052 -(XXJ 04/97) R254152-000 04/97) DEPARTMENT OF LAI3f)R AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL :';� A; 3l %�` �REGIST xr ?# ,EXP : DATE o g o C CO1 :': ;*ORTH(i�I 275JF10 /09/2003 W C° EFFHCT �TEjD,�i4,' ii;(�.l 104./0 WI N.. wo NORTH WEST •HANDLING SYS ; .INC m 1100 SW:77TH ST — D RENTON WA 98055 -2939 Detach And Display Certificate REGISTERED'AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. ' #': • ;EXP. DATE CCO1 ' /09/2003 EFFECTIVE 04/06/1973 NORTH ".WEST" ;HANDLING SYS INC 1100 SW 7TH, ST RENTON WA 98055 -2939 Signature Issued by DEPARTMENT OF LABOR AND INDUSTRIES _/ Please Remove And Sign Identification Card Before Placing In Billfold .+;;':. 'Ayr, aa ... Q" Mam alai Mawr al� PM SON llrt Milt ar.t Pim OW . ilr Pule OM rr + I ...a.. , alarm Pk%OW V DIEBOLD INC: SEATTLE FACILITY Consrtuction & Demolition Drawing I I I DOM HIGH DOORS Truck Weil >rx i Truck WWI MINIM c=11 i Truck well FLOOR/WALL TREATMENTS ISHC /PNTI IEC /PNTI I :ACT /PNT, [VCT /VC -1I [VOC /PNT I iCPr/VC -1 ICPT /VC -21 (CPT /BDR /vC -2I - SEALED HARDENED CONCRETE WITH PAINTED WALLS - EPDXY COATING ON CONCRETE WITH PAINTED WALLS - VINYL COMP. TILE WITH PAINTED WALLS -- VINYL COMP. TILE WITH VINYL WALL COVERING - WALK -OFF CARPET WITH PAINTED WALLS - CARPETED FLOOR WITH VINYL, WALL COVERING - CARPETED FLOOR WITH VINYL WALL COVERING - CARPETED FLOOR & BORDER W/VINYL WALL COVERING F1 1,..E COPY understand that the Plan Check approvals are suoject to errors and omissions and approval of ans does not authorize the violation of any adopted code or ordinance. Receipt of con - tractor's copy of approved plans acknowledged. Date Permit No ,9 fto:; 41, 4 2 -<9 w4/ -14 tk. 401 1, - -,z,st t ,4 1 '�,, o d * , -o, • /G C- 1/8' =1' f Construction Legend Existing Walls Wall to be Demolished New Stud Wall New Demising Wall Store Front C,Irt OF TUKWILA *ROW JAN ; 5 2003 4; 'c) RECVED cm OF JAN - 7 2003 PERMIT Gp tO?fc%j5 a, a, a, cn z 0 F- a 0 J 0 O CU Cw a S • • oft • CNJ .-- I TYF / 1.5 " BOTH SIDE TYP,' SEC. A—A 1 t 1 1/2" I t -.07" SEC. B —B BRACE TO COLUMN CONN. BASE PLATE r 6 " 7 3/4" 12 OP •44 4 1/8 V I (2)-1/2"0 ANCHOR BOLTS PER BASE PLATE 3 ; /2" EMB. , (SEE NOTE NO. 4) • TYP 2 1 B TH'K =3/8" FY =36 KSI. (ASTM A -36) SAFETY LOCK 1/4"0 RIVET 7,/ 16"0 RIVET ASTM A354 -79 BEAM CONNECTOR 44 FRONT VIEW SIDE VIEW • • • • • • r TYP ---- 1/8 :s • 6 6 • • • TH'K =3/16" COLUMN SECTION w I fht 1 3 ; 1 5/8" GENERAL CONFIGURATION ,• \ i . \\ -' ) of „ -i. ,,-- f- „ L .� '�''/ .4- - a. %>- , jar '� i Ix .-1 _,4 ) � 4.,�1 J j / _ � \ j ) " ! - i ' `,, . � ' ',:.>-, �• tip r J r - - l'.., i i . ���� ) i''' k .�.�' \ ` e j 1 3/4" BEAM SECTION 2 A u fr NOTES: Cr= S DTI► OF TUOMM.A APPROVED JAN 1 5 2003 As w i t.1) DIVISVON I. 9' JPL,. \ •�• v r . C` " g : t ST J * M r �7 ►�yv` I s ✓ F. \T v -Y r -� r r- - ` D . 2_ C. ... �, r - r r v ♦ • . .,, ✓ `- . : 'te r.` - - - '1 A s` '�' `"' • v;' 5 - CC Rr...P _T4 .`rte _ J ^ tP'• ^ ~ 211 �.� ♦ �� N •' - :L - . • VL �• r i• -- CP V :.E v r.S� 9 - ) ^''�� �). _`ry �. ✓ _s `C S•-••'.. � _ "' ` �� v `► H �. " t � ' L i�l11� 12- 241-03 RACK DESIGN AND ENGINEERING 3:8t L.4 CRESCENT,' 4L F s24 GLEND.ALE CA 97208 DIEBOLD INC. .4 - - -."_ CTTY OF TUBA JAN — 7 1003 PERMIT CENIEFI Nor