Permit D03-087 - CITY OF TUKWILA - CASCADE VIEW PARK - GAZEBO
CASCADE VIEW PARK 14211 37T" AVENUE SOUTH D03 -087 Parcel No.: 1523049095 Address: 14211 37 AV S TUKW Suite No: Value of Construction: $ $4,544.00 Type of Fire Protection: Type of Construction: VN Water Meter: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Tenant: Name: CASCADE VIEW PARK Address: 14211 37 AV S, TUKWILA, WA Owner: Name: TUKWILA CITY OF Address: 6200 SOUTHCENTER BLVD, TUKWILA WA Contact Person: Name: RICK STILL Address: 12424 42 AV S, TUKWILA, WA Contractor: Name: OWNER AFFIDAVIT IN FILE - RICK STILL Phone: 206 767 -2344 Address: CITY OF TUKWILA PARKS & RECREATION, 12424 42 AV S Contractor License No: Expiration Date: DESCRIPTION OF WORK: CONSTRUCTION OF A NEW 400 SQ FT GAZEBO STRUCTURE WITH LIGHTING Public Works Activities: Channelization I Striping: N Curb Cut / Access / Sidewalk / CSS: N DEVELOPMENT PERMIT ** Continued Next Page'`* D03 -087 Permit Number: D03 -087 Issue Date: 06/06/2003 Permit Expires On: 12/03/2003 Phone: Phone: 206 767 -2344 Fees Collected: $188.06 Uniform Building Code Edition: 1997 Occupancy per UBC: 27 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Profit: ?? Non - Profit: ?? Water Main Extension: N Private: N Public: N ?? Printed: 06 -06 -2003 ' i ii:. ��:. S. i:", �5: 77k:t ?t: + a. • au.�...... , Permit Center Authorized Signature: 4404 � Signature: Print Name: tG% doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 D03 -087 Date: Date: I hereby certify that I have read and examined thi permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfojmance of work. I am authorized to sign and obtain this development permit. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 06 -06 -2003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1523049095 Address: 14211 37 AV S TUKW Suite No: Tenant: CASCADE VIEW PARK PERMIT CONDITIONS Permit Number: D03 -087 Status: ISSUED Applied Date: 03/19/2003 Issue Date: 06/06/2003 1: * **BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 5: All structural concrete shall be special inspected (UBC - Sec. 306(a)1). 6: All structural welding shall be done by W.A.B.O. certified welders and special inspected (UBC - Sec. 306(a)5). 7: When special inspection is required either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name, permit number and type of inspection being performed. 8: The special inspector shall submit a final signed report stating whether the work requiring special inspection was, to the best of the inspector's knowledge, in conformance with approved plans and specifications and the applicable workmanship provisions of the UBC. 9:. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 10: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 11: All wood to remain in placed concrete shall be treated wood. 12: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 13: Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation off -site or into existing drainage facilities. 14: The site shall have permanent erosion control measures in place as soon as possible after final grading has been completed and prior to the Final Inspection. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances doc: Conditions D03 -087 Printed: 06 -06 -2003 Plf Signature: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Print Name: �. D03 -087 Date: 6-6.- 0 3 Printed: 06 -06 -2003 SITE LOCATION King Co Assessor's Tax No.: /3'230 y 1O9S Site Address: 14211 37th Ave. South, Tukwila WA 98168 Suite Number: Floor: New Tenant: [] .... Yes []..No Tenant Name: Property Owners Name: Mailing Address: Name: Rick Still CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 City of Tukwila Mailing Address: 12424 42nd AvP. S. Tukwila WA 98168 E -Mail Address: rick@ci.tukwila.wa.us Contact Person: E-Mail Address: Company Name: archetype Mailing Address: 2108 10th Ave. W. Contact Person: Lydia Al dredge E -Mail Address: Contact Person: E -Mail Address: '4ppilc4ttuns permit A pplicapun t 1.2CO3 archetype @earthlink.net Duane Edwards dle @cosmogrp.com 12424 42nd Ave S., Tukwila WA 98168 Building Permit No. Mechanical Permit No. Public Works Permit No. (For office use . only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * "Please Print ** P:t!'l' 1 Nu'r a➢rW City ARCHITECT. OF RECORD —All plans must be wet stamped by Architect of Record Seattle, WA 98119 Ciry Day Telephone: Fax Number: City Day Telephone: Fax Number: 'rre State Day Telephone: 206- 767 -2344 city state Fax Number: 206- 767 -2341 Company Name: Mailing Address: City Day Telephone: Fax Number: State Contractor Registration Number: Expiration Date: **An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** State Zip 206 -285 -4257 206 - 282 -6729 ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Cosmopolitan Engineering Group Mailing Address: 117 S. 8th Street, Tacoma, WA 98402 Zip State 253- 272 -7220 253 - 727 -7250 Zip Zip Zip • . r. ��` 4s. riuSCY '�J54.G�Y:'`cw':'.;;Y.ii4'�afCi BUILDING PERMIT INFORMATION - 206-431-3670 Valuation of Project (contractor's bid price): $ le Poo. --- Scope of Work (please provide detailed information):�� Number of Parking Stalls Provided: Standard: Water ❑.. City of Tukwila Water District Sewer .. City of Tukwila Sewer District Q. 0.. Septic System (If property is served submitted at the time ■apphcauonr\penntt application (1.2001) 1: :001 El.. Water District 1 Existing Building Valuation: $ Will there be new rack storage? ❑ ...Yes ❑ .. No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overltangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Compact: Handicap: Will there be a change in use? ❑...Yes ❑ .. No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ .. Sprinklers ❑...Automatic Fire Alarm ❑...None ❑ .. Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑...No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. UTILITY DISTRICTS: Note: If the utility district is not City of Tukwila, you must provide written verification and approval from that utility district at the time of permit application. E... Highline Water District 0... City of Renton Water District . Val Vue Sewer District ❑...City of Renton Sewer District by a septic system, 2 copies of approved septic design from King of permit application) Page •kno.cw ❑ ...City of Seattle Sewer District County Health Department must be Existing Interior Remodel Addition to Existing Structure New Type of Construction per UBC Type of Occupancy per UBC , 1' Floor "ice tr 2 " Floor 3' Floor Floors • thru Basement . Accessory Structure* Attached,Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION - 206-431-3670 Valuation of Project (contractor's bid price): $ le Poo. --- Scope of Work (please provide detailed information):�� Number of Parking Stalls Provided: Standard: Water ❑.. City of Tukwila Water District Sewer .. City of Tukwila Sewer District Q. 0.. Septic System (If property is served submitted at the time ■apphcauonr\penntt application (1.2001) 1: :001 El.. Water District 1 Existing Building Valuation: $ Will there be new rack storage? ❑ ...Yes ❑ .. No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overltangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Compact: Handicap: Will there be a change in use? ❑...Yes ❑ .. No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ .. Sprinklers ❑...Automatic Fire Alarm ❑...None ❑ .. Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑...No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. UTILITY DISTRICTS: Note: If the utility district is not City of Tukwila, you must provide written verification and approval from that utility district at the time of permit application. E... Highline Water District 0... City of Renton Water District . Val Vue Sewer District ❑...City of Renton Sewer District by a septic system, 2 copies of approved septic design from King of permit application) Page •kno.cw ❑ ...City of Seattle Sewer District County Health Department must be PUBLIC WORKS PERMIT INFt (MATION -206-433-0179 Scope of Work (please provide detailed information): Street Use: ❑ .. Street Use Land Altering and /or Hauling: ❑.. Land Altering: ❑...Cut Storm Drainage: ❑ .. Storm Drainage 0... Flood Control Zone Monthly Service Billing to: Name: Mailing Address: .pplicauanatpertnn application 1 I •:00]► I Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑... Channelization /Striping Water ... ❑ Call before you Dig: 1- 800 - 424 -5555 cubic yards 0... Fill ❑.., Curb cut/Access /Sidewalk cubic yards ❑ .. Hauling Sewer Information: ❑ .. City of Tukwila Sewer District 0 .. Val Vue Sewer District ❑...City of Renton Sewer District ❑ .. City of Seattle Sewer District ❑.. Sanitary Side Sewer ❑.. Sewer Main Extension ❑ ..Private ❑.. Public Water Information: ❑ .. City of Tukwila Water District ❑ .. Water District # 125 0... Highline Water District ❑...City of Renton Water District ❑ .. Water Main Extension ❑ .. Private ❑ ... Public ❑ .. Water Meter/Exempt: Size(s): ❑ .. Deduct ❑ ... Water Only ❑ .. Water Meter Permanent #: Size(s): ❑ .. Water Meter Temporary #: Size(s): ❑ .. Est. Quantity: gallons ❑ .. Fire Loop/Hydrant (main to vault) #: Size(s): ❑ .. Landscaping Irrigation ❑ .. Miscellaneous: Page 3 Sewer... ❑ Sewage Treatment ❑ Day Telephone: Ci& State Fire Line .... ❑ Zip Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace> I00K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /I,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM incinerator — Comm/Ind MECITAMCAL PERMIT INFORMATION — 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name Mailing Address: State Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance** Valuation of Project (contractor's bid price): S Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... ❑ Fuel Type: Electric ❑ Gas ....❑ Other: Indicate type of mechanical work being installed and the quantity below: PERrVIIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: ,((, Print Name: Rick Still Mailing Address: 12424 42nd Ave. S. Date Application Accepted: ,3 -19-03 Date Application Expires: ? -/%.23 City Day Telephone: Tukwila, WA 98168 City Staff s: Zip Day Telephone: Fax Number: Date:Vis 206 - 767 -2344 State Zip Payee: TRANSACTION LIST: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Z RECEIPT ,� W Parcel No.: 1523049095 Permit Number: D03 -087 6 5 Address: 1421137 AV S TUKW Status: PENDING N o Suite No: Applied Date: 03/19/2003 co w Applicant: CASCADE VIEW PARK - GAZEBO Issue Date: w _ CO W wO Receipt No.: R03 -00353 Payment Amount: 188.06 g Q (o Initials: SKS Payment Date: 03/20/2003 08:58 AM = w User ID: 1165 Balance: $0.00 Z H H O '. ZF-- L1.1 uj CASCADE VIEW PARK ACCT 301.00.594.760.XX.58 n 0 O ( o 1-- wW Type Method Description Amount I U.. -O Payment Other 188.06 .. Z U = O~ BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/345.830 000/386.904 111.25 72.31 4.50 Total: 188.06 Printed: 03 -20 -2003 Z RECEIPT ,,_ W re 2 Parcel No.: 1523049095 Permit Number: D03-087 Address: 1421137 AV S TUKW Status: ISSUED co o . Suite No: Applied Date: 03/19/2003 co W A III i pplicant: CASCADE VIEW PARK Issue Date: 06/06/2003 WO 2 Receipt No.: R03 - 01128 Payme Amount: 47.00 co a Initials: SKS Payment Date: 09/15/2003 12:05 PM H w User ID: 1165 Balance: $0.00 z I— O Z 1— U) uj Payee: CASCADE VIEW PARK ACCT 301.00.594.760.41.58 v N O c o O t-- W w = U Type Method Description Amount IL 0 Payment Other 47.00 Ili w U = O I -.. TRANSACTION LIST: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PLAN CHECK - NONRES Account Code Current Pmts 000/345.830 47.00 Total: 47.00 2100 09/16 M0 TOTAL 0.00 Printed: 09 -15 -2003 Z Z RECEIPT ; ,_ z re w Permit Number: D03 -087 6 o Status: ISSUED co o Applied Date: 03/19/2003 w Issue Date: 06/06/2003 _I H co ur w Receipt No.: R03 -01128 Payment Amount: 47.00 E co Initials: SKS Payment Date: 09/15/2003 12:05 PM H W User ID: 1165 Balance: $0.00 z I.- 1- O ZF- W Payee: CASCADE VIEW PARK ACCT 301.00.594.760.41.58 v N co O w =— Type Method Description Amount u_ r- Z Payment Other 47.00 U co }- _ O '- Parcel No.: 1523049095 Address: 1421137 AV S TUKW Suite No: Applicant: CASCADE VIEW PARK TRANSACTION LIST: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PLAN CHECK - NONRES 000/345.830 Account Code Current Pmts 47.00 Total: 47.00 Printed: 09 -15 -2003 z Projecy L.CISCO \is\ - 'tn,/ � a1■. Type of Inspection: r \nt,t Address: \ TV At/ $ Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 13 00 3- OS - 7 MC' pproved per applicable codes. O Corrections required prior to approval. COMMENTS: — Yervv‘■-lt GPM lnspecto Date: 021 EJ $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: \ \) \ ?tAJ Vccr,C ' ..-Pc A A Jc l v e v-at .Pv 4 yowl --\-4.....,\ \& \ c ); - -C-AoIAi l r‘c Special Instructions: Rp PC r srA\ t r)Y\CY -- a, owt /4 a.m. P.m. Requester: Ct r^ nt4-S \(/` OY\e v f 4 P -,/D ter! Op9YOvro Pro CiScCAP \ \) \ ?tAJ Vccr,C Type of Inspection: Spe°etcif c Address: "' -, lI , ,/ Date Called: Special Instructions: . Date Wanted: a.m. P.m. Requester: Phone No: i z INSPECTION RECORD Retain a copy with permit X03 -087 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 D Approved per applicable codes. El Corrections required prior to approval. inspector:. r -261„ Date: � $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: PrAect: (( `' G�SCG de V 1 ew �G AZ— Type of Inspection: F rG w► I - Address: \ ( 3 - 1 Air 5 Date Called: 5 Special Instructions: Date Wanted: S - LS "041 a.i P.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. J Corrections required prior to approval. COMMENTS: v'G IM t C) w 1 0I-e I-ev_ ¥PV1 (-PC( PA( 0—t'—Pr k A VG, ki; S Inspector: "�� Date: S ) $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: - gS"_ 4 1 S7 Type of Ins ectign: // � --.'H n . 7 m L'l Y r 1 )1 r a.l it - ciAti ry • c ppio�1Att - see , iepOrt I . ...,,�: :._) ?rov`k d ofr caA;ov. £ -c Q. (p c + r .. l . r , a -k t v\(A i of D n r o vof I 3_ 1 �t i 't yu\ \' 1 * 4r 4 idvv .s+ lab ..`it-.)r L tp9/0 ' P.m.: 5 'i r c tot Epa., \-�-5 `, h r o,r , ,f-e,... J.\ . ()C vkio r`Cs - 1 at ppi ova I ij04.e .. 1 h\ s )1 S+ vv h o- be C 0 o oVA -e.. as -A 1 Q. ItOW Ov v * C C /C. ` 1S ho`F (7)1 r- P qr\ 1\ A.5e'ACA t o irk re'CUVcc5 atr.e 1'Y1► Py ject: V f,f.0 'i" Type of Ins ectign: // � --.'H n . 7 m L'l Y r 1 Address: I Date Called: 247/0 Specia Instructions. ,, e 4if 14 VV►I( 0,1(4.0 /6' kl i Date Wanted:' m. L tp9/0 ' P.m.: Requester: L 1/1:1 Ct 1751)46 Po No: ne I INSPECTION NO. El Approved per applicable codes. `I INSPECTION RECbRD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 up.3 •I Corrections required prior to approval. Inspector: Date: L _ QLi El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: I• 1- IIOW - etrld1 - k CCrd nc + I v1 — )rA t V-4. ('1 V\ S% '"\'f . 2-. -I i VA 5 cI - �ch, Y ' e cnrc\s Pnt.sSir • C) bicA ■ v1 P t (�, Q S. c $ , P �nn Cc r c +n � ; (ilv\ \r�s, icy. . f PC Of A\ 4 rnvv■ ciA- 110e 1 Cev' ver 3.' rrA■ r r0 Pc.4 s covr► -4-e ()FR r r - ev∎sin,.. ' z 1$SS -klLe LS 1 12 taus\ t Sv 7 to .s$r-ci es • n j-1-,718 _ Ozq 1' }, 5- 1.0vIe ct ( .ff?roVcA \ .-.1-0-r (1.e %Ov% . II icy-e � � cov\- -cic\ ev' e l `, weer ilia, \ oe bo tiro cinc, Lk) r. Project: �) ` 1..OkYP ( U R eW ROxr\,. Type of Inspection: �Ye(%/V rc, Address: D ate Called: I 1-1-)m 0 Special Instructions: Date Wanted: n j-1-,718 _ Ozq a.m. p.m. Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit D03 -08 PERM (20 • )431 -3670 rE1 \ Corrections required prior to approval. Inspecto Date: _) - c p - \ ❑ $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • COMMENTS: J`� ' / i� / ll/o r /4,t/ 5e 6 S / Tvc, 1 q-) // '7 / S iQPa, s,6 -- A) A/ A fi) --N- Geer, CY 4,l- ,/1' tos • Requester Phone N om` 06) ..d `,` f s k,„ / 1,- , A PA /A , ,...6 33 ,I2 Pr ect:, . / / CA i- J`� ' / i� Type O ff (Inspection: / _ 1� 4-m 6— . fit/ 1 q-) // '7 / S Date Cali e. — Wanted: Special Instructions: Date ._ CAD, �d . - / ® 03 p.m. Requester Phone N om` 06) ..d `,` "n:".t11 r;'.Iw %vint:Wiu4.�4 +. ?d wit t,iW <.:} dt'.76 .uaC 'k ' uu . 4. 14 ii:s i41Fa".,'v:tii'i:. .4�, ":lii::: b:,?.. ,..;. ",.emu. 5 INSPECTION NO. . CITY.OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ctor: INSPECTION RECORD Retain a copy with permit ..r Isk Qncrf'ct equired prior to approva Date: $47.00 REINSPECTION EE REQUIRED Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 00: Call to schedule reinspection. Receipt No.: Date: Pro'ect: r t s , X . , Type of Ins ection: A dress. W J7 4 % a Date ailed: Special Instructions: Date Wanted: o 3 �L Reques-ter:�� Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. D Corrections required prior to approval. COMMENTS: 4.L. 404 i -rte $47.00 REINSPECTIOIWFEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: (206)431 -3670 COMMENTS: Type of Inspection: /7°44 . �isn, Address: /4-q.,/-37 f 7 -t!. /?i 5 , e ?7 , ,r11 J l�'� , 9 - 7 1 - -t . cf P.J� G;>... 19 C-- C 11 1 h C L j d / 1)e1f.. i L 1ii.1Q 4i,A,0, ' J- -.P'' /e/-/ ,./j; 6\ , 4,4 . t-, , - � -C17 � '/� �?f i A P v . S-7 A rte, cr /4 /4 � a ,4,, d , �/ /:i" �' _ �- d' (Q.,. -, � ) / 7 7 I- p � C4 // .Q_ c 2 r -� / -3 7e , c» 2-a, - 3% r- 6,S y? , I. 1 �if 4G . /I G A f?J�,O • , nn 4J 1.' /: / I G` .. l a " e9 - Projec • (,rrs Cade I. /, `ran , Type of Inspection: /7°44 . �isn, Address: /4-q.,/-37 h' CD Date Called /Q.-• -0.3 Special Instructions: i"? r Date Wanted: 4m; 10--.37%—°3 o3 Request y Phone No: G , 2.6 C / 23 a Approved per applicable'codes. Inspector INSPECTION RECORD Retain a copy with permit , INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 IrA .' (206)431 -3670 O 4 r 20 - 7 -1q - ?CO • C orrections requir d prior to approval. Date: /0. 3 $47.00 REINSPECTIOt1 FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Projec C-. 9-4 4 L f Gf Type of Inspection: , iP, .FYI /* 4 /'''/7 Li./f' 4 Address:., 3u _ Date Called: Spe ial Instructions: Date Wanted: a ' Request : Z.", r d �ee(�hi Pho o: - { -1? A pproved per applicable codes. COMMENTS: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206 431 -3670 0 L.- '4? e7t,,4---, / �T ID Corrections required prior to approval. 0 $47.00 REINSPECTIOit( EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Z ; I-- • Z • W 6 iO O 0 N 0. J H N u_ W O 2 L < _ Z �.. W U c o 0 H W L 0 w Z 0 ~ z Proje „. A( p O 1/4 et-('I?ct-dk Type ciLlnspection: 1 , t-i)v-irdCrtiovi i-c-k,- I IS Date C alled: Address: I 'q 1 I 7)7 A-t) S Special Instructions: , — \C)--'14/vi. / a - I Date Wanted: A 71° (i iii . Requester: LL-101,4 a A IdA Phone No: , V ... zo L.,- ,1:(? -1- - 1.)`; 7 INSPE ON NO. Ei Approved per applicable codes. . , . , INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 PE NO 4,1 • (216)431-3670 Corrections required prior to approval. COMMENTS: (ir/e.„ 2.4. s — / Inspector: bt,._ A )-P Date: 1/24e)-) cfrzi—D3 $47.00 REINSPECTION FE EQU1RED. Prior to inspection, fee must be paid at 6300 Southcenter B vd., Suite 100. Call to schedule reinspection. Receipt No.: Date: L:. P ect: i. . (t 1V L Type of Inspection: -- ( > e o�,v Co / A I1 L 2/ / 3� Date Calle �S/0 Special Instructions: eel cc-/- I P� Date a 5 t d:_ / tt Re ues r Lydick. : /c/ricifi.e Phono: - Z0G -ZS6 - 42.x INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERM CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. 1)0-087 (206)431 -3670 COMMENTS: k i . -t7 l d i .. .11.r .40.0" l, , 4 Corrections required prior to approval. l $47.db REINSPECTIO EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcen r Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS:..( j , 45 ,,,. 1 3 t ' i e. cc (r Gc ` o 0 0 IM . ( 1 - P - C 7 ' P . C o 1l1.t+ e-, 1(17 i U.' z 1. 11 ej-1 \ � Ci \t? ( n a y) Ip 6 \C c n 14 ) %. ft £2 _ _ (A,.. S 1 U1/4. 'Tar 'i Z> l I � C-P Pr, ✓"-�- - c.� P 7 r) ■t .. r P,0C 1k 4 scr- 2 (A 5 pee V t ; (.01 eke r 3 - R-.1arw�, Loar'c — s mt os-- ! 1 t l ( D e r -L f> r % cal,/ Jr - c-5 c>..X)..r° C 1-e - - v\e„ •, v, t. IAA) „l, v tA.1" -N. (- 0 \) 'e r( 5. , o'"- re r ,r. ..Z 4 .. Y ov, ck-(::) \ (A ■A , a Li r' c Phon No: i 15 rwic — c')6.v.v.,e'.4, ()Li 5 4-.. Cow Project: Typ,s of Inspection: Address: /4'c // 37- �q /.' S Date Ca led: - c ,2 ,7 — �'. Special Instructions: Date VI/ nted: —�/ ,-03 a.m. N.,,,. Re uester: 1 //)/,' Phon No: i 15 5"'• • Approved pe r ag�3licaW.e INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 orrections required prior to approval. Inspector: / Date: El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspecticin. Date: Receipt No.: J COMMENTS: of Inspection: -?% // I . ' [ A O \v" (A r:, ',It, G vN A if n 14 Adc r s, 11 3704 Ave t ? nn + 0 in' S ■ B .../ S • ell Instructi • .. /` ' r ' r -) Rrnki l< Of \late ; -;c c \-t i o,., (9 rC A :m: . C r\ \ of( Val Phone No: , = . - 9 / , k - 5 // - pro 3.) fiu`sv\ G►h C.4NorAvoocs 0 3 -a-0 SOi \ c "e( 1'Lit \-D -PO v An $ 40 .s -\-tee j Project: . /. 926 . W O� " 1 of Inspection: -?% // f /f2 Adc r s, 11 3704 Ave t Date C a lle 7 , / 3 .../ S • ell Instructi • .. /` ' r ' r ns: > ('(� / /' Date Wa _t d • 3� 3 rC A :m: Requester:.- L Phone No: , = . - 9 / , k - 5 // - 7 9 INSPECTION RECORD Retain a copy with permit IA) INSPECTION NO. PERMIT'0. CITY OF TUKWILA BUILDING DIVISION ,v 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ( 06)431 -3670 j Approved per applicable codes. Corrections required prior to approval. Inspector: Date: .� iJ 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: May 19, 2004 AMEC Project 3-91M-14713-0 City of Tukwila 6200 Southcenter Boulevard Tukwila, Washington 98188 Attention: Mr. Scott Moore As requested AMEC conducted special inspections for the following: 1. Reinforced Concrete (cast in place) Respectfully Submitted, AMEC Earth & Environmental, Inc. L / 4/C Tyler McCormick Business Unit Manager AMEC Earth & Environmental, Inc. 11335 N.E. 122 Way, Suite 100 Kirkland, Washington USA 98034 Tel (425) 820 -4669 Fax (425) 821 -3914 www.amec.com ame RECEIVED MAY 2 0 2004 TUKWILA PUBLIC WORKS Phone: 206 -571 -6323 Fax: 206 - 433 -1833 Subject: • Final Letter of Special Inspections Cascade View Park Dear Mr. Moore: AMEC Earth & Environmental, Inc. (AMEC) respectfully submits this letter to acknowledge that special inspections and materials testing have been completed for the above - referenced project. AMEC conducted inspections for this project from July 7, 2003 through August 29,2003, as described by our Daily Field Report Nos. 1 through 5 and corresponding laboratory test reports. These reports, copies of which were previously submitted, form the basis for this final summary of our inspections. It is our understanding that the work which was inspected as referenced in our Daily Field Reports, was constructed in general conformance with the approved plans, building codes, and changes authorized by the structural engineer. If you have questions or desire additional information, please call at your convenience. W:\ Protects \14000s \14713 Clly of Tukwila \Cascade View Park Final Letler.doc 05/21/04 08:01 FAX 2062826729 ARCIIT;ii.x 05/17/2004 09:91 2062820710 Information Build 'boomin • Consulting • Tinting May 17, 2004 File No, 712 -30167 Building Inspections City of Tukwila Building Department 6300 Southcenter Boulevard, Suite 100 Tukwila. WA 98188 Subject: Project Name Cascade View Park Project Address 144th Street & 37th Ave. Perm it No. D03-D87 We have completed the requested special inspections on the subject project. Our final report. dated September 15,2003 is numbered FR40071. To the best of our knowledge. all work inspected conformed to approved plans. specificatior s, UDC. and related codes, and /or verbal or written instructionsfrom the Engineer of Record. Sincerely, PROFESSIONAL SERVICE INDUSTRJES, INC. Gordon Lloyd, Project Manager. Seattle Construction Services Department cc: Lydia Aidredge, Archetyie PSI SEATTLE WORK INSPECTED Epoxy grouting of dowels RECEWED �;'► 21 2004 D EPARTMENT NT Profeesionat Service Industries, Inc. • 3257 18th Avenue, West • Seattle, WA 9811 99.1706 • Phone • Fax 20tJ282 -0710 r 003 PAGE 02/02 w ' i+ C' w4k1' a: 1LiY+ �F': iC VA" vJrrA. W�Re4W'�5u;`k ;�':'✓:`sYl,vor..r DATE: DH /cam cc: NA Information To Build On Engineering • Consulting • Testing CLIENT: Lydia Aldredge Archetyle 2108 10th Avenue West Seattle, WA 98119 September I 5, 2003 INSPECTOR: D. Howard REMARKS: REPORT OF INSPECTION ACTIVITIES _ PROJECT: Cascade View Park 144th St & 37th Ave. Tukwila. WA PERMIT NO.: D03 -D87 JOB NO.: 712 REPORT NO.: FR40071 A PSI representative inspected epoxy grouting of #5 reinforcing steel dowels for columns. Checked hole depths (12 ") and cleanliness — holes cleaned with brush and compressed air. Dowels were grouted using Sikadur 32 1- -Iigh -Mod LPL Epoxy in conformance with manufacturer's recommendations. \YORK CONFORMS TO APPROVED PLANS: Respectfully submitted, PROFESSIONAL SERVICE INDUSTRIES, INC. Gordon Lloyd, Project Manager REPORTS MAY NOT BE REPRODUCED. EXCEPT IN FULL, WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES, INC. YES Professional Service Industries, Inc. • 3257 16th Avenue, West • Seattle, WA 98119 -1706 • Phone 206/282-0666 • Fax 206/282 -0710 NO SUMMARY OF FIELD DOCUMENT TRANSMITTALS Document Type Document No. Document Date Transmittal Date Inspection Report 1 07/07/03 07/14/03 ame 11335 NE 122nd Way, SuIte 100 Kirkland, Washington, U.S.A. 98034.8918 Tel (425) 820.4889 Fax (425) 821 -3914 To: City of Tukwila 6200 Southcenter Boulevard Tukwila, WA 98188 Attn: Scott Moore Enclosed for your review and records are our most recent Daily Field Reports and associated field correspondence pertaining to the above - referenced project. W:\Fietd Document Transmittals \14000's \14713.0.wpd FIELD DOCUMENT TRANSMITTAL Date: July 14, 2003 Project Number: 3-91M-14713-0 Project Name: Cascade View Project Manager: Steve McDuffee Permit No.: 03 -097 RECEIVED AUG 0 4 2003 PUBLIC WORKS Date Report No. Inspector Deficiency Noted ' Corrective Action Proposed Corrective Action Taken Report Date & Closure No. • No Deficiencies Noted Field Report Transmittal Project #3-91M-14713-0 Project Name: Cascade View Park ame Project Name: Cascade View Park Project Number: 3-91M-14713-0 . W:1FIeld Document Transmittals 114000's114713.0.wpd Deficiency List Page 4 PROJECT NAME a sc-So r� CCt &l \D f C c Cfl v.G f C II C PROJECT NO. 3 / P 17 - o REPORT NO. I 6 60 0 k +At Mott. ripe, of Act,." Irk LAr ADDRESS Q , 6 rc 'c.. . �e j ofd PERMIT NO. DATE (1 CLIENT Ci:+ oC 17, 1oti7 I tA (tij Vext W Lo WEATHER otltvrcey)i- PAGE (Includes Test Reports) I OF L STRUCTURAL ENGINEER CO svvto pcli- . AMEC PROJECT MANAGE PHONE NO. -5- m6,v1 cc ARCHITECT lik a-� L AVM REPRESENTATIVE/PAGE NO. Cfl/�it: r CONTRACT 7 h Qblorr 1e' C ntic-rc _ TYP OF NSPECTION R�� NEW INS El RE-INSPECTION A l .L O ( CT rvtcC, p Af c I G f i'ts CcT P CCt &l \D f C c Cfl v.G f C II C ►`tcc Y►.�t v�T D� & -Azebo 6 60 0 k +At Mott. ripe, of Act,." Irk LAr —sT` Q � -�1 S. OiNvk Q , 6 rc 'c.. . �e j ofd g44\ o� ek A - 4 Cy (1 E A-ct. w vi (tij Vext W Lo C ntic-rc _ v t vt-- kr_ 40te. , . t ,1 r Arti ( [Pw& DAILY FIELD REPORT AMEC Earth & Environmental, Inc. 11335 N.E. 122 Way, Sulto 100 Tel (425) 820 -4669 Kirkland, Washington 98034 Fax (425) 821-3914 To the best of our knowledge, all items inspected as noted above were in general 8 Yes ❑ No conformance with the approved plans and specifications. AM 'T Fl ' 'RE ENTATIVE Yes REVIEWE amec' ❑ Preliminary Observations ❑ Deficiency Correcte Report No. C , THIS REPORT IS CONSIDERED PRELIMINARY AND SUBJECT TO CHANGE PENDING REVIEW BY OUR PROJECT MANAGER This report is provided solely for the information of our client. This report is not intended to be transmitted to a third party by any means, except in full, without written permission of AMEC, Inc. AMEC Earth & Environmental, Inc. (Rev. 11,00) (ONCRET ASTM C -39 GROUT ASTM C -1019 MORTAR (TYPE ) CMU (TYPE ) PRISM UBC 21 -17 SHOTCRETE ACI 506 R OTHER ASTM C -780 ASTM C -140 • h ... t11 C ck : c P _ re \_— PROJECT NO. 3 Rtvv\- c t-t - 713 0 REPORT NO. PAGE (Includes Test Reports) Z OF 2 DATE c � 7- t,J 3 FIELD DATA BATC D SUPPLIER l O 06- vl TYPE OF CEMENT MIX NUMBER S O WEIGHTS PERYARD DESIGN ACTUAL TICKET NUMBER 32703( CEMENT (LBS.) CL f 1 5''/ / TRUCK NUMBER y 3 3 FLY ASH (LBS.) BATCH SIZE, YD r, COARSE AGG. (LBS.) . TOTAL PLACED I I OF ( YDS COARSE AGG. (LBS.) WATER ADDED, GALS. C.9 COARSE AGG. (LBS.) 1,59 C ?J B ALLOWABLE WATER, GALS. 3-7 FINE AGG. (LBS.) 1.2- ? � O C) l 2, DRUM REVOLUTIONS — WATER (LBS.) 2& 7 Z I BATCH TIME I 2,oe4 AIR ENTRAINMENT W .5 L I . 5' SAMPLE TIME l2 t.5- ADMIXTURE NO. 1 FINISH TIME ISO ADMIXTURE NO. 2 SAMPLE AND, TEST DATA SAMPLE SET t OF I LABORATORY SET # 1 I.D. # 13 b Net SAMPLE LOCATION: _k _ yr, F. DESIGN STRENGTH 00 PSI @ 2e , DAYS 'TEST DATA _;..`:..; SPECIFIED ACTUAL TEST AGE (DAYS) � - Z-EZ 22A, SLUMP (ASTM C -143) &I 51j r( SPECIMEN (NOJSIZE/TYPE) L( if -c') V.5 AIR CONT. (ASTM C -173/C -231) r -- DATE SAMPLED 7— 7--0 AMBIENT TEMP °F •--- `72 DATE RECEIVED - 7- - 8 _ 0 3 SAMPLE TEMP. (ASTM C -1064) 5 - 4 63' CURING CONDITIONS CO VG`G,) UNIT WEIGHT (ASTM C- 138) HIGH/LOW TEMPERATURES YIELD (ASTM C -138) '--- 'Note appropriate test methods itdffwsnt from those indicated • r AGRA • ENGINEERING GLOBAL SOLUTIONS 11335 N.E. 122nd Way, Suite 100 Tel (425) 820 - 4669 Kirkland, Washington 98034 Fax (425) 821 - 3914 SAMPLE STORAGE LOCATION AND COMMENTS AGRA FIELD PRESENTATIVE / " % R I ED BY TEST REPORT THIS REPORT IS CONSIDERED PRELIMINARY AND SUBJECT TO CHANGE PENDING REVIEW BY OUR PROJECT MANAGER This report is provided solely for the information of our client. This report is not intended to be transmitted to a third party by any means, except in full, without written permission of AGRA Earth and Environmental, Inc. AG19378 (Rev.6199) Report of Compression Test Results Client: CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD TUKWILA, WA 98188- Attn: SCOTT MOORE Specimen Type: Concrete Mix and Field Data CastDate: 07/07/2003 Type of Placement: Location: N.E. BASE. Time Test Result 13649 A B C. D ASTM -C39 Strength: Required (f c) : 2500 psi @ 28 Days Mix #: 5809 Supplier: STONEWAY Load: of Truck #: 433 Ticket #: 327436 Plant #: - Batch Size (cy): 6 Water Added (gal): Admixture: Batch Time: 12 :04 Sampled Time: 12:45 Finish Time: 13:11 Nominal Spec Date Age Specimen Lab Id Id Received Test Date (Days) Size AMEC Earth Environmental, Inc. 11335 NE 122ND WAY, SUITE 100 KIRKLAND, WA 98033 Tel (425) 820 -4869 Fax (425) 820 -3781 07/08/2003 07/14/2003 07/08/2003 08/04/2003 07/08/2003 08/04/2003 7 28 28 Break Types: — (Cn) Cone, (CSp) Cone Split, (SCh) Cone Shear, (Sh) Shear, (Co) Columnar Type of Caps: — (Un) Unbonded, (Su) Sulfur Based Compound, (Gr) Grinding Reviewed By: - • w. Distribution: Client: 56 File: ® Suppli Other: Addressee (2) www.amec.com Report Date: July 29, 2003 Project #: 3-91M-14713-0 Project Name: CASCADE VIEW PARK Address: 144TH AND 37TH TUKWILA, WA Project Manager: STEPHEN McDUFFEE Architect: N/A Engineer: N/A , PO #: N/A 4x6 12.62 31490 2500 4x8 12.57 4x8 12.57 4x8 12.57 ame Contractor. Inspector. DAVE BERNIER Actual 6.25 Slump (in) ASTM C -143: Air Content ( %) ASTM C231: Unit Weight (pcf) ASTM C -138: Sample Temperature ( °F) ASTM C -1064: 63 Ambient Temperature ( °F): 72 Yield (cy): Clouds Condition: Water Content Ratio: Precipitation: Cement Content (ibs/cy): Wind Condition: Remarks: REFERENCE REPORT #1, SET 1. Specs N/A N/A N/A 50 -90 N/A Actual Area Compressive Strength Break Field Type of Percent (in') • (Ibs) (psi) Type Cure Cap of Req. Hold [] Un 100% 0 0 0 ,03/18/2003 17:30 FROM HERLOCKER ASSOCIATES TO 12062826729 CASCADE VIEW GAZEB FILE COP•( STRUCTURAL CALCULATIONS UNIFORM BUILDING CODE, 1997 EDITION ROOF LOAD: DEAD LOAD 1SPSF SNOW LOAD 25PSF WIND LOAD: UBC SECTION 1615, V 8 OMPH, EXP.B SEISMIC: ZONE 3, Ca.36, SOIL: ASSUMED ALLOWABLE BEARING 2000PSF. CONCRETE: 28 DAY COMPRESSIVE STRENGTH F'c=3000PSI. 5 % SACK TYPE 2 .. CEMENT PER C.Y., 5" MAX. SLUMP. SPECIAL INSPECTION REQUIRED PER UBC SECT 1701. ' REINFORCING: ASTM A615 GRADE 60 (FY Fs- 24KS1). LUMBER .ROOF FRAMING LUMBER SHALL MEET THE FOLLOWING GRADES AS A MINIUM: RAFTERS: DOUG FIR/ LARCH NO. 1 (Fb = 1000PSI) BEAMS: GLUE - LAMINATED 24FV8 (Fly = 2400PSI) . STEEL: ASTMA36 FY= 35KSI, F ALL WELDING BY WABO 'CERTIFIED WELDERS. c,N TLj w M/1R19 • PERMIT CEN 2 P.02 03/18/2003 17:31 FROM HERl.00KER ASSOCIATES 4. \ \1 LANCE HERLOCKERASSOCIATES Client A tf'Y IS. • CAMANO ISLAND, WA • Project €J15(*$t Y t>f/hJ P►Rs- Subject • 4i-yr ti. Nakt Date L /2 q LPLCHK RA t 1 I1 4s ers rI 4, •. Oa, env., . 1 ► tti Inge ' } • iS'r3! wp : Z rpyF Nsu n,+ I y thh : 11:111)11, sr! : • L.} Z, � ,__' I111 crac►) lilts)` 1.5! t t9 q 14,41.1. (d.t; _1 t, »v tbttSpo l holm Z. 4,1- ,t •"?h, • • TO 12062826729 P.03 No Sheet 1 / • X13/18/2003 17:31 LANCE HERLOCKER'ASSOCIATES Client CAMANO ISLAND, WA Subject • G 344,0 tv Date -)7 ►V' CHK � ri -*1 74 (v rt7 e 4*) 4- • . gM 4o 'h Y �� •` h S3�z C12.7f)=• �F /rz .,Sr•rti,? S4.1 C h, rS,3 L. a.1,► Li `40 /; . • 5∎k ► j 131.11:6, l0..I'Stti • • • ' • (.4itdj::: 4 3 ' /B x tb .G L, _log x 1 .s_... !.l). FROM HERLOCKER RSSOCIRTES TO 12062826729 10.vr g , :r 44. f sacs +- y31, s us 4s) (z:rio Project 1" vt tkikt. No. + i I •r S K ph .41 'NV %.\ Pett v zy,K lb) tirlrl� s.t y2' Sz3 � 11 al c ir `..._ ... �. .04 Sheet 3'f 6, 3 613 sv F ve0 J /gxto 91./LQj a" Vi4 03 17:32 „ FROM HERLOCKER ASSOC IRTES LANCE HERLOCKER. ASSOCIATES Client My+t. • GAMANO ISLAND, WA . Project hS is% V& 1,1140MI e No. Subject erk*r 1 3+4'5 rKf; r•4 • . •- fir 0- P /1 / 2 tt Date ti I 7 -Y1t3 CHK E. ,, iX)v et). F = ct 14 it ''LA ("IV ;•�-4 goA 10. G ) J --L, M•* of Zirrt it 144 TO 12062826729 1 . t t 1 Z c1, I hes. e I t tS f.w,S , x , r.'1 v . , r.. ..�.', P. 05 (;►iiv) 3r? '!L.) ' 749 (,a v Sheet 3 { r, x A ra-- v�.r trtr >ti zr Q s,- tossy10 1 07)) 2 1. /i fi-r kr 1•14 L Lt4J / 14 I 1 1 MAT be r,) '. 3 ri & i=n Falb ti 0 .2.15 , , - • 5 7 6 °T. i t 3..0 r y t (U t 1 (tif.. (L,r- •1 .:.e-D > CUL , 1C' 311( — ,&) (�#1X Ii '' .. 1.124 1 — ,5P) ()rvvOtt +- z ( d' T 7 L tilYxVr7 t 19)y ,47 (I rv)CV y,13 ° it " ah;:?btaa� s 03/18/2003 17:33 FROM HERLOCKER ASSOCIATES LANCE ASSOCIATES CAMANO ISLAND,. WA,.. . Subject 6 4i v ..,c v;Rv4G'IE h&M y S 4 ► = 7 t r''., • « .A • 1.1 ((:�'_ -) • •17 . N: . • • ..,;: j4) ' 1.1,1 t 3,rNC r T Client Project U1Sc -n n'� V hA R i� No Date 311/43 CHK S w1P A Gti. /0104, • NA) ht. �- -►. � a C �- ?lrlr a 1-1►1Y C 1 -‘ 4 ;3it 11, ?A') ti 4•1 -z r Yr ' ; of. 07F t o.rsr • o z► • 3 r, F k 'L 6 In) TO 12062826729 lb' a ; 1 z. 1 4 I4,r (6 ii x )1 I k 1 j y_9 • X 10.r jo ZMSSr� V /it ICr• Gairy A• '1 T• 4 - Z2 .06 , Sheet 4/. t �'3' r 1 . -- ° •- —1 r1, g I�3a •.. 3 rot 3 vtw( StM 31►344 . L.41. tbrio ( 34 Lip IV .,. ,:��'` g� [i�3ik �+` »ai';tiSi✓a.Iii�i%riL�r isS slt'.•i.':uin; i''.,uu�u Sv"i4d *',2f' k't 4i 03/18/2003 17133 FROM HERLOCKER ASSOCIATES TO 12062826729 P.07 A. fig: � LANCE HERLOCKER. ASSOCIATES CAMANO ISLAND. vyA subject. G *'•3 s 6'a Gr 1s Fi(. tett , t. tbarrim 4,v U Y�4L 5.1.) ..' I. ( , tll 6%1 r 4 • • . 10 Athi4e). . r 1r . 1 4 *' ; °S• Li/ l7 J()fl - ,) _ t , 11W . 104 4 M� N, #41 • •'s) 3 °'' C tr = fy )2t t 7/6 y'' - ,�.,: !wL v) - 91/4 iy Iry rryf • ttl t . 177 v (/) 1 s Client A "-wave' 1 . Project CA'St 4-6 V' vl. 3 ,J No Date 1/111a_ CHK /v ' 6•'7. .aMk : �c �, , G1,1 Ts ' rerS14% I (1) g •.c Ff44fo I frt �N r 4 - F- 7 H; j 7" I u 41.. • 1 tj Avt~ leXld R. ( , A.) f elv'* IL4 - l 4 ►: b,, r � Sheet f • z i1- z J U U CO CO u1 J 1- w u _ (.0 = z � z 111 uj 0 oF- ur u j w U N H 1. z 03/18/2003 17134, FROM H5RLOCKER ASSOCIATES TO 12062826729 • (J - * rx ' -. S , y DeAS 7 `"' P.08 I- OrX r1" AuaFA r • 09/24/2003 11131 FROM HERLOCKER ASSOCIATES 9/24/03 Lydia Aldredge Archetype 2108 10* Ave'. West ' Seattle, WA 98119 Re: Cascade View Gazebo: revised concrete strength. • Lydia: • This is to verify:that the concrete columns for the Gazebo were actually designed for F'c=2500psi and.that special inspection is not required. The mix design called for is to ensure the quality of the concrete.; please.call if you have questions. Sincerely, LANCE HERLOCKER ASSOCIATES a A. Herlocker Lance Herlocker Associates TO 12062826729 P.02 3-De7 �: •,�y. c iTr: ru�z D c /1 41 C1RCHARD LANE. CAMANO ISLAND, WASHINGTON (360) 387.5933 • ••• 09/24/2003 1132, FROM HERLOCKER ASSOCIATES • UNIFORM BUILDING CODE, 1997 EDITION • ROOF LOAD: DEAD LOAD 15PSF SNOW LOAD 25PSF WIND LOAD: UBC SECTION 1615, V=80MPH, EXP.B SEISMIC: ZONE 3, Cr.36, ..... SOIL: ASSUMED ALLOWABLE BEARING 2000PSF. • CONCRETE:18 DAY COMPRESSIVE STRENGTH PcZO 5 'h SACK TYPE 2 CEMENT PER C.Y., 5" MAX. SLUMP.-SPEGIALFINSPEpC;FION • • 1424PERAD46144186626*44". (441 nit ves*P3 t-5 FOR FOA0616 o IDOMA41 • . Ctatr 4141.1 5PISCAkt. rarioN2 Is iaoT kg& Lift ep REINFORCING: AS A615 GRADE 60 (FSOKSI, F&-24 LUMBER: ROOF FRAMING LUMBER SHALL MEET THE FOLLOWING GRADES ' AS A MINIUM: RAFTERS: DOUG FIR/ LARCH NO. 1 • BEAMS: GLUE-LAMINATED 24FV8 STEEL: AgTIVIA36 PLATE. FY=35KSI, F241CSI. CERTiieltD WELDERS. • . •• • • .‘ STRUCTURAL CALCULATIONS • • , • . , • • TO 12062826729 CASCADE VIEW GAZEBO 1). ALL WELDING BY WABO •.o.r.1• (Fb = 1000PSI) (Fb 2400PSI) P.03 111.0 1244iVO 10 5i) ee-n cf bev_a •fat Prvvr, r t y l Fc, conRif.re. •i-RJE06r14., MI% 0E14,0 Acti Ai tss tIft 6,44•111 • 09/24/2003 FROM HERLOCKER ASSOCIATES LANCE HERLOCKER Client_ u� �1 Y'0 CAMANO ISLAND, WA Project (A 5 tA')'t u 14M1 PA AIL No Subject Z A ie rs v Date 30 LD) CHK . Sheet . � wwG C41. ;:: lei froton L. • S. R #AGE *ISM �r 7►x1' 7 7 �i -3r z a, A• ci - ' 5.n. 1 1).t1 • L i r r 'I *V j:1•M7G:)'•c Z`'t•41► • &2 • t.? Lt z zt.crs,f 1 4, • .14 .: l.'r.r Z`r, 17 N. ::( 1. ►') . s Z r.,rj 6 :IC Lr:.4) = 2 - 1 1 , 11/11f • .p.. tv' C IP 1 22.1 a -t SWtAng. # -•R •A. 3►Iti/ f �"�') r 7 C ir.7 rl C 4. 1t •'f G IMa'SV r •I,Tip,r C -1Aderi 7 tZ k7.0 ? sr" *s�e�st lp Pit TO 12062826729 Z 'c) 2kSS� 30144 ,; tPer k'ft• t thra,7 4 z (2U n II/ • W O . f r• i'i . iitP tv Y t visit f6r fl " 1, 114 , -- to s, f c t oast . G h,; 1;✓44i =t S4 6 /t G G t 4 3 s y •R r. r- S11 C lg. , pti� Gen. v z. 3e P lSv to qo— k /r 1 1. P.04 t* Li P • 09/24/2003 11133 FR HERLOCKER ASSOCIATES LANCE HERLOCKER•:ASSOCIATES Client A- rtas2t e Nth CAMANO ISLAND, WA Project 6 Z'ifL 0 No L Subject Date/ Z S CHK Sheet Gp AJ G{,f ti,x, A itN ow. 541A susi:e Eh. y • 1 3 &t o e / A A4 1 /4& \N ttr a7Ty lta iy - 9`'f4L b sS S,1ux,t %.)c Ix)eu:i4V • C e: gagt � • <1RGci ,. • 1 1,r i7 ;'s:S,ty }� _ 3bbS•.00. ,r_, /4 caL; t34 • uR. !tot, e tct :4107 ` 1 ^ Z r (19) ? ( 4 -) Ho (- a t) t '1191 f ` `1 !, 1.1 ( 6-Lifir) = ?,e R '�j� •fit 1 TO 12062826729 �N 4 z14 z n 11 ) qi.fc 1.10/ 1)•) tol,5 s ) i a 1 " /t 4s 0 7 301) (60 ,2 • . (-.q. ,trC Er j) (ZI ) ty47.& ZI ) = 5 45 i 31,.3r)(G?trfa ) • sC3e'v• 11 '6,0', . I 'f q D1 r 4 t: i d o S;'gvt (17401:$3041. = $3041.' • S 3041. 1 4 x ( 1'!s - e 3 - v�- w a � 311,1 /4ro -2. Ago 14t • . s(64.'f'K. l r� _ &vita c v1) lope)) `4 BLS ri�y� r1/4:t, 1ty r r. ' r=? 2.13 t • nt. Ali P.05 t t c•.V•1 / �7 ‹.4, it r >� eta K/2, f.'t Z y—Dv, . t • 4 '/1•1 ' • born Paa bits, 2/11/04 I undr.. •• FILE CO (. _ Lydia Aldredge Archetype 2108 10t Ave. West Seattle, WA 98119 Re: Permit D03 -087 Cascade View park Gazebo Revision #1 TukNOIa building Division Comments of 12/23/03: .11 y nF TOKWII q Lydia: MAR 3 1 2004 Following are my responses to the Tukwila Building Division comments: PERMIT Items la), lb), lc), & 1d) have been checked and are all acceptable as built. Item le) requires the addition of some new connectors: 1. The main N -S & E -W horizontal beams (4x 12 + 2x 12) are not connected to each other (4 locations): Add two H8 vertical straps from beam to beam (alternate corners each location) and an A35 framing anchor beam to beam (opposite sides each location). 2. The 4x8 hip members are not attached to the 4x12 beams (8 locations): Add two H8 vertical straps from beam to beam (alternate corners each location) and an HG10 framing anchor beam to beam (opposite sides each location). 3. The 4x4 posts between the 4x8 hips members and the 4x12 + 2x12 horizontal beams do not have adequate uplift resistence (8 locations): Add a vertical H8 steel strap tie from the column to the horizontal beam below. I have marked up the framing plan to show the changes that need to be made to the drawings. Also included with this letter are my response letter to Mr. Rambo at the Tukwila Building Division and a set of calculations. Please let me know if this satisfies your needs and if I can be of further service, Lance A. Herlocker Lance Herlocker Associates LANCE HERLOCKER ASSOCIATES OF ��Mt1llA CORRECTION TO sioN No z b05 - 08 7 CONSULTING ENGINEERS 2151 ORCHARD LANE, CAMANO ISLAND, WASHINGTON (360) 387.5933 ..V.;14 1.4 CONTENTS: CALCULATIONS R CASCADE VIEW PARK GAZEBO AS -BUILT CONDITIONS STRUCTURAL CALCULATIONS CORRECTION 1 -3 -to ISIONNOI Z. RECEIVED CITY OF TUKWII•A MAR 3 1 2004 PERMIT CENTER o87 ..,.._ s'i�(U��:.:w.. wtif3: ss fl.'d J:•Skwivlk .'a�'+`d i� L'S:.z+iJ' `A...�. l w' J.:1rLYnC.+:JL`.4 1L7 n •�'tir uu a'. `�.' ��'�` . . �'rt °' . "• +'•'ty',.k:'r,ska,rt:./ti•^ LANCE HERLOCKER ASSOCIATES Client 4 MY/M. CAMANO ISLAND VERIFY AS-BUILT CONDITIONS . TYPICAL BRACES TYPICAL HIP CONNECTION . December 23, 2003 Lydia Aldredge Archetype 2108 10` Avenue West Seattle, WA 98119 Dear Lydia: Cii of Tukwila Department of Community Development Steve Lancaster, Director RE: CORRECTION LETTER #1 to REVISION #1 Development Permit Application Numbers D03 -087 Cascade View Park — Gazebo —14211 37 Avenue South This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Bill Rambo, at 206 431 -3670, if you have any questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `revision sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, Stefania Spencer Permit Technician encl xc: File No. D03 -087 Bruce Fletcher Rick Still �GL Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 as z s9: kni;isr 'Sdi ifs 3yx {i�zc�: a:. , 4 April 7, 2003 Mr. Rick Still 12424 42n Avenue South Tukwila, WA 981868 RE: CORRECTION LETTER #1 Development Permit Application Number D03 -087 14211 37` Avenue South — Cascade View Park Dear Rick: This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time, the Planning, Fire and Public Works Departments have no comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `revision sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, Q•GCes. Stefanie Spencer Permit Technician encl xc: File No. D03 -087 city of Tukwila Department of Community Development Steve Lancaster, Director %rGrrc.- 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 Steven M. Mullet, Mayor PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D03 -087 DATE: 03 -31 -04 PROJECT NAME: CASCADE VIEW PARK - GAZEBO SITE ADDRESS: 14211 37 AVENUE SOUTH Original Plan Submittal Response to incomplete Letter # X Response to Correction Letter # 1 TO X Revision # 2 after before permit is issued DEPARTMENTS' 1 A .s Building Division Public Works ❑ Fire Prevention Structural ❑ ❑ Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04 -01 -04 Complete [ Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROyTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS 0 CORRECTIONS: Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Documents /routing slip.doc 2 -28.02 PERMIT COORD COPY DUE DATE: 04 -29 -04 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D03 -087 DATE: 12 -15 -03 PROJECT NAME: CASCADE VIEW PARK - GAZEBO SITE ADDRESS: 14211 37 AVENUE SOUTH Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 2 lafter /before permit is issued DEPARTMEN Build Divisi Public Works w0 iz -Z3- n ❑ 0 Fire Prevention Structural DETERMINA N OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ ❑ Planning Division ❑ Permit Coordinator DUE DATE: 12 -16 -03 0 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire 0 Ping ❑ PW ❑ Staff Initials: TUES /THURS ROOTING: Please Route @I Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions 0 DUE DATE: 01 -13 -04 Approved (attach comments ❑ Not App ( ) Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: /Z - Z 5-05 Departments issued corrections: Bldg " Fire ❑ Ping ❑ PW ❑ Staff Initials: S' Documents /routing slip.doc 2-28-02 DATE: Snip 444, t?,LrAn� DEPARTMENTS: Building Division Public Works ❑ PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D03 - 087 PROJECT NAME: CASCADE VIEW PARK SITE ADDRESS: 14211 37 AV S DATE: 9 -12 -03 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Is Issued Fire Prevention Structural n Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: ASAP Complete Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUT NG: Please Route I Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved m Approved with Conditions n Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2-28-02 ;7Y DUE DATE: ASAP Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ct�cs+t?�+r•rnn"�mnwn+a;�rn4 :�� ACTIVITY NUMBER: D03 -087 PROJECT NAME: CASCADE VIEW PARK SITE ADDRESS: 14211 37 AV S _Original Plan Submittal X Response to Correction Letter #1 DATE: 04 -21 -03 Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: Buildin Public Works Documents /routing slip.doc 2-28-02 PLAN REVIEW /ROUTING SLIP 4 -13-0 APPROVALS OR CORRECTIONS: Fire Prevention ❑ Planning Division Structural ❑ Permit Coordinator DETERMINATIQN OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04 -22 -03 Complete Comments: Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: rr* Not Applicable ❑ DUE DATE: 05 -20 -03 DATE: 1N#+.?r(vyivtPrn.^Ya + r ACTIVITY NUMBER: D03 -087 PROJECT NAME: CASCADE VIEW PARK SITE ADDRESS: 14211 37 AV S Original Plan Submittal X Response to Correction Letter #1 DATE: 04 -14 -03 Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works 0 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ APPROVALS OR CORRECTIONS: Documents /routing slIp.doc 2 -28.02 COORD COQ R PLAN REVIEW /ROUTING SLIP Fire Prevention Structural ❑ Permit Coordinator Incomplete 0 REVIEWER'S INITIALS: PERMIT COORD COPY Planning Division DUE DATE: 04 -15 -03 DUE DATE: 05 -11 -03 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D03 -087 PROJECT NAME: CASCADE VIEW PARK SITE ADDRESS: 14211 37 AV S X Original Plan Submittal _ Response to Correction Letter # DATE: 03 -19 -03 Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: , 4 � Z �� Building Div4 G[t Documents /routing slIp.doc 2 -28.02 Complete d Public orks APPROVALS OR CORRECTIONS: PERMIT COORD C( riY PLAN REVIEW /ROUTING SLIP 0 M51 i1a ' � - Z0 OS Fire Prevention Structural ❑ Incomplete na REVIEWER'S INITIALS: PERMIT COORD COE( 3 _Z .-O Planning Division [� I) Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03 -20 -03 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RO)ITING: Please Route , l-J , ' Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 04 -17 -03 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) N Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Lei;' >t: °.risk �rar:Waxvutw .aa w;kwas Revision • No. Date I Received Staff t Initials I Date Issued i ''Staff Initials / / z- 0 3 I S =�' ( • ,s -0 6 . 1 -,�� Summary of Revision: 4.4',€;(._ ' a ; m > -(>7. f �7(- � lCil_G ei- Vi e'- - � ewLGs , TO -1 7 Received By: l ,--1 L, 41 ` _ Received By: 7, / 7 t7 ,-,-w Revision No. 1 I Date Received t Staff I Initials Date Issued i . Staff Initials 02 I 42 -�5 - a 3 SieC V- 7 0 Summary of Revision: /�?.eJlStof �Pdd a eet -cie sv ce ewLGs , Received By: Received By: / Al 41 ` Revision No. Date Received Staff Initials Date Issued Staff Initials i Summary of Revision: � Received By: Revision No. Date ' Received Staff Initials Date Issued i Staff Initials � I Summary of Revision: Received By: . PROJECT NAME: �i1-5e /' Site Address: / // 37 %Iv S REVISION LOG PERM!T4NO:. Z23-- pcP7 Origind, Issue Date: —0 Revision No. Summary of Revision: Date Received Staff Initials ;?7;«aspC.kxaXt4 Received By: / j /U. (pleae print) Date Issued (please prim) please print p Staff Initials • ' .tiy Y`a'i i+ 1 t1� L!i�1l':N.{ tir::wt �,. w.+ uf; rm ;yeirxitl4i,lkfliGiN:ikiifu,v: ivi Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /S1 Plan Check/Permit Number: 0 2 3 'afl37 p Response to Incomplete Letter # g i Response to Correction Letter # Revision # '2 after Permit is Issued Project Name: Project Address: Contact Person: Summary of Revision: City of Tukwila Department of Community Development Steve Lancaster, Director Pr2 view � J1// Vr'ri .�. 12101/R 19 eiQ:c Phone Number: 20 2 014:7--47 r-Pr>P p Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by:GS Entered in Sierra on 3-v-0 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431 -3665 1 Atial' ;tY John W. Rants, Mayor gret, I 3 44 F/ /7 a ZOOS NT FA r?ttiF >�S krSL* 06/29/99 City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 1 y�� f. , tFr ;:t kC . "e. ? a.. N,.,�.;' s. i:t'•}.v.: %!'Y.�.. 2 41, ri..•�`t.G.'y. r�.: sjR� •.a: Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: i/10 Plan Check/Permit Number: 0 Response to Incomplete Letter # El Response to Correction Letter # [] Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: G f ��/ ' i V/ ii/ f 9f jc Project Address: /4'2/ J 7 777-/ - / e S. Contact Person: of e /9 Phone Number: ( 213 s Summary of Revision: iti,vilw jeor p /fi//( J;f/J f-p iG Vti 6/9toulp0A&Th G m , OP r A DEC 1 5 2003 PEPMIrce Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 08/06/03 2 7 7 City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: !/ J2.'/o ' Plan Check/Permit Number: PO- -U7 0 Response to Incomplete Letter # Response to Correction Letter # Revision # 1 after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Person: Summary of Revision: Nrw �rt� 7 t orf/\/t 2 c."16efoe v erl/ MOP 1421/ /He/yr Phone Number: (2) RECEIVED CITY OF TU SEE SEP 1 2 2003 PERMIT CENTFq Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by:C a l Entered in Permits Plus on 08/06/03 I�wiY14a�.�1L Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 0g /7 0 Response to Incomplete Letter # Response to Correction Letter # 0 Revision # after Permit is Issued Project Name: 60r/ id I t Project Address: /,PZ// --- 77# /We. Contact Person: (-20(9 2g - 2 77 �/ / / /7 ����.�� , � Phone Number: Summary of Revision: /7 / f City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Plan Check/Permit Number: 0 . 6 - - 7 OIT O E uKW PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: •- Entered in Sierra on 'Sr' /603 % PR 1 8 2003 08/30/00 City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: / I2 / i ? 3 Plan Check/Permit Number: 7 0 . � — 0E3 7 [0 Response to Incomplete Letter # X Response to Correction Letter # i [] Revision # after Permit is Issued Gil AB Project Name: Project Address: l f Z // 7 • s Contact Person: t L - f f7 /19 / ` l % t v i e .7 Phone Number: Z Summary of Revision: fl f'2 f /f'107 (1 if Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Sierra on - A7v mzfrv5zi, F197a RECEIVED Ukyy APR 1 t 2003 PERMIT CENTER 08/30/00 -ry - ,? CITY OF Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON COUNTY OF KING AFFCONT 1/13/00 ss. 1. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. , and will therefore not be performed by a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. KEN ON' F O i � s :0 NOTAR Y 1 * . ; i :0 CO i � I PUB LIC+ t i ia d>:.'• -0 ••,� �� -9)-,:•• 22 .• ‘‘ OF Wit,SVI' rcRrY- ia•.,�At $'vt M4,Yg.k:a" 4 t.44.44. , states as follows: APPLICANT Signed aid sworn t\ efore me this day of ' V 20 © . 4A,/ NOTARY PUBLI C�P,GC /�Q i s nd for the State H -4 ashington, residing at ,rte Name as commissione•: /� L. bvIva y My commission expires: County. ,4== mw.rjrn;! 17,2^,r,a ;w_.drs;4i* maw: 7r^' F94i^. rnle*I VI: itlil IKW,+y ,i: ' M".' ' 18.27.090 Exemptions. This chapter shall not apply to: 1. An authorized representative of the United States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of a structure; 6. Any construction, alteration, improvement, or repair of personal property, except this chapter shall apply to all mobile /manufactured housing. A mobile /manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than $500, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division AFFCONT 1/13/00 of the operation is made into contracts of amounts less than $500 for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner who contracts for a project with a registered contractor; 12. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but this exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 1 Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 14. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his license; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; 16. Contractors on highway projects who have been prequalified as required by chapter 13 of the Laws of 1961, RCW 47.28.070 with the department of transportation to perform highway construction, reconstruction, or maintenance work. i�a'FItH'k:4AY.Y }Tdk?i n'lC • SITE LAYOUT & REFERENCE PLAN CALL UNDERGROUND UTILITY LOCATE SERVICE: FILE COPY 1-800-424-5555 2 DAYS BEFORE DIGGING. FUTUR SIDEW (T)1 W• —f' TOWERS --AY EA. END 6 CONC. MOW STRIP Ci+tu SIGN WALL PEDESTRIAN UGHT COLUMN FOOTING 4_ CONC. PAVING i 4" CONC_ PAVING R =1Q' R =36' R =14' FOUNTAIN PAVEMENT T «= D A / w MP 0 AREA R =17' --' REMOVEAB BOLLARD EWALK CONC. PAD TREE PROTECTION FENCING (TYP.) (SEE NOTES & DETAIL THIS SHT.) EXISTING FENCE' \ACID' PROTECT, \ \ . — 18" HIGH CMU SEAT WALL 6' RADIUS 2 GAME TABLES W/ SEATS r" APPROX. 180 L_F_- cI4AtNL1NK , FENCE- - - PRO-PERTY LINE _-� � ~ � -~ ELECTRICAL E GAME AREA - SEE — NOW 1 understand that the Plan Check approvals are subject to errors and omissions and approval of ! plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. "H F r S3 '�1,:L BE MADE TO .., - :7c-2,C7,--"Z OF V4 C WITHOUT PROR �..+VAI- OF TUKWILA BV� I � �� � � �. RE�i1 WILL REWIRE A PLAN PrveE"bb FEM. tkul INCLUDE PROPERTY LINE NO2 °E3 + SEPARATE PERMIT REQUIRED FOR: D ECHANICAL ELECTRICAL 0 PLUMBING L E] GAS PIPING CITY OF TUKWILA BUILDING DIVISION EXISTING FENCE, PRESERVE AND PROTECT PROPERTY LINE S OD SCREEN pt 1 a • 0 lb i GENERAL NOTES 1. STAKE OUT SITE ELEMENTS (WALLS, WALKS, BENCH PADS, TABLES, FOUNTAIN, LIGHT /GAZEBO FOOTING LOCATIONS, ETC.) FOR OWNER REP.'S APPROVAL PRIOR TO BEGINNING CONSTRUCTION ON THAT ELEMENT. 2. PROVIDE SCORE & CONSTRUCTION JOINT SHOP DRAWINGS FOR THE PLAZA PAVING FOR OWNER'S APPROVAL. SCORE & CONSTRUCTION JOINTS IN WALKS WILL BE 6' O.C. SCORE & CONSTRUCTION JOINTS IN PLAZA PAVING ARE SHOWN AT 15' SQUARES. 3. SEE SHEET 11/19 & DETAIL 4/9 FOR INFORMATION ON ELECTRICAL HOOKUP TO SOURCE AND LOCATION OF ELECTRICAL PANEL. PROVIDE ELECTRICAL CONDUITS & STUBOUT WIRING IN J- -BOXES IN GROUND NEEDED FOR ELECTRICAL EQUIPMENT ON SITE INCLUDING FIVE LIGHT FIXTURES, TWO FUTURE LIGHT FIXTURES. IRRIGATION CONTROLLER AND ELECTRICAL DUPLEX RECEPTACLES AT POWER PANEL & GAZEBO. 4. PAY FOR ALL PERMITS REQUIRED FOR WORK DONE UNDER THIS CONTRACT. 5. GAZEBO STRUCTURE. PARK PEDESTRIAN LIGHT FIXTURES, PLAY STRUCTURES, SWINGS. (PLAY AREA PEA GRAVEL, FILTER FABRIC AND WOOD FIBER UNDERLAYMENT), BENCHES, AND TRASH RECEPTACLES SHALL NOT BE PART OF THIS CONTRACT AND SHALL BE PROVIDED AND INSTALLED BY OTHERS. 6. PROVIDE PLAY AREA PERFORATED DRAINUNES AT EDGES AS SHOWN ON SHT. 2/19 AND GRADE SUBGRADE 0 1% FROM CENTER OF PLAY AREAS TO EDGES. 7. DRINKING FOUNTAIN, PICNIC TABLES AND GAME TABLES WILL BE OWNER PROVIDED & CONTRACTOR INSTALLED. CONTRACTOR WILL BE RESPONSIBLE FOR ALL CONNECTIONS & EQUIPMENT NEEDED TO MAKE DRINKING FOUNTAIN FULLY FUNCTIONAL. 8. TIE 1-1/2 DRINKING FOUNTAIN WASTE WATER LINE TO EXISTING 6 SEWER STUBOUT (VERIFY LOCATION W/ CITY OF TUKWILA). SEE DRINKING FOUNT. DTL. 6/7. 9. PROVIDE PARK SIGN SHOWN AT NORTHEAST CORNER OF SITE PER CITY'S STANDARDS AS SUPPLIED BY NORTHWEST RECREATION; PO BOX 608, TUALATIN, OR 97062 - -0608. 10. PROVIDE 24" WIDE CONCRETE BAND WIDTH SMOOTH TROWEL FINISH AROUND PLAZA AS SHOWN. FINISH OF PLAZA WILL BE MEDIUM BROOM FINISH; (PROVIDE ACCEPTABLE SAMPLE OF FINISH CONCRETE TO OWNER PRIOR TO INSTALLATION. 11. PROVIDE 3' --0 x 8' -0" CONCRETE PADS FOR FOUR BENCHES (N.I.C.) NEAR PLAY AREAS. 12_ BLOCK OUT 10'X20' RECTANGLE AS SHOWN ON PLAN FOR FUTURE GLOBE ART. SEE DETAIL 5/7. SEE APPENDIX SHT. AB. 13. GAZEBO PAVING SHALL MATCH GRADE OF PLAZA PAVING. BLOCK OUT 4'X4' GAZEBO FOOTING OPENINGS IN PLAZA, GAZEBO FOOTINGS (BY OTHERS). SEE APPENDIX SHT. AA_ ADDITIVE ALT. NO. 1 ADD CMU SEATING WALL AND TOWERS AROUND EAST SIDE OF PLAY AREAS. ADDITIVE ALTERNATE #1 SEAT WALL SHALL BE PER DE TAIL 10 i7. • 1 t ,I IRRIGATION CON TROLLER TERMINAL BOX W/ TERMINAL STRIPS LE VI TON 5280—W 1 SIGN WALL CAP COMPACTED EXISTING SUBGRADE CMU. SIGN WALL TOWER DETAIL (Thl NO SCALE 0 SQUARE CONC. CAP WITH SACK OR SMOOTH FINISH ATTACH CAP WITH RETAINING WALL ADHESIVE SPLIT FACE, NATURAL COLOR CONCRETE BLOCK. SPLIT FACE BOTH SIDES AND ENDS WHERE EXPOSED FINISH GRADE OF PAVING FRONT VIEW #4 REBAR BOND BEAM @ 24" 0.C. (4) #4 VERTICAL BARS IN SOLID GROUT FILL C.M.U. COLUMN # REBAR AT 10" O.C. BOTH WAYS CONC. FOOTING — (SEE DETAILS C SHEET AA) • • - ' ELECTRIC CONDUIT STUB -UP DETAIL ("6 NO SCALE �.�. SB— 24CR 120V CABINET (SPECIAL) TERMINAL STRIPS CB— 323218 CONCRETE BASE CONTROLLER ENCLOSURE DETAIL ,(7n. SCALE: r =r —o } DRAW` c DIAGRAMAT1C_ AC PANEL & CONDUIT LA YOU' ALL BE PER RECD CONDt?10Pi.S & ELEC. CODE_ r - - CAP • • LANDSCAPE GRADE BEHIND SIGN WALL (2) #4 REBAR BOND BEAM SOLID GROUT FILL C.M.U. WALL #4 VERTICAL BAR AT 48" O.C. (MIN) CLEAN DRAIN ROCK BEHIND WALL COMPACTED SUBGRADE • • w_ 9 " RGS FINISH GRADE a 1" PVC SCHEDULE 40 ELEC. CONDUIT W/ PULL WIRE FROM J— BOX TERMINAL STRIPS . :■• • CMU SIGN WALL DETAIL NO SCALE 11. SIDE VIEW SLOPED CAP (SIGN WALL) (7 - 5/8"X15 - 5/8"X3 - 1/4") SMOOTH FINISH TOP OF GROUT FLUSH WITH BLOCK EDGES; MORTAR WALL CAP CORNER PLAZA PAVING SPLIT FACE, NATURAL COLOR CONCRETE BLOCK. SPLIT FACE ON SIDES AND ENDS WHERE EXPOSED #4 REBAR AT 10" 0.C. BOTH WAYS ELECTRIC METER ELECTRIC PANEL, SINGLE PHASE; 110V, 100 AMP; GE OR APPROVED EQUAL PROVIDE (2) FOUR POLE CONTACTORS AND PHOTO CELL OF APPROPRIATE VOLTAGE AND AMPHERAGE FOR ACTIVATING PARK LIGHTS I- GALV. CONDUIT PER CODE GROUND WIRE CONDUIT PER CODE GROUND GRID PROVIDE 3" ELECTRICAL CONDUIT FROM CONTROLLER ENCLOSURE TO as THIN 3' OF EXIS'. POWER VAULT. COORDYN A TE W/ SEATTLE CI TY LK -' T TO PROVIDE AND INSTALL '+E LAST 3 INTO THE V'E" CAUL T. SE A TTE_E LI GI-+ T WILL INSTALL THE CONDUCTORS TO MME TER AND ME TER. PROVIDE 1 F CO1M f okii OA f QN CONDUIT FROM EXISTING COI*JUN_ JUNCfON 80X TO CONTROLLER ENCLOSURE_ • r` tab Imp -U -me I i1I (1�I 11 mi I b 4 1 1 ►1� [ Il.1I� a I11►�Y11 V I ��l ►1 ®��l����imi� ®ice■ ��i1i� ��i�iC�imi mom mg= NNE 111 11112111111111. MEM. IMMEMEr iffilliairrrrri■:' =at SIGN LETTERING -- 8" HIGH X 1/4" THICK FLAT CUT ALUMINUM LETTERS WITH PAINTED SEMI —GLOSS FINISH. INSTALL STUD MOUNTED FLUSH WITH EXTERIOR CONC. BLOCK SIGN WALL. OWNER SUPPLIED 1 CONTRACTOR INSTALLED SMOOTH FACE BLOCK BEHIND LETTERING -.......... i , _''-........ in miiiiiiiIiiiiii ■ I� ■_ . . ._....._._..........._..._ ...._..— _......____._NM - MI IIIIIIMMINIMill1111111111111111111111•111111111111=11•======111111=1111111011111111111111111111111 111117.• 15■111111Fri-----------------------_.■■ .M■ r FENCE SECT :ON SCA.E: u /2. _ 1 -0 . SPLIT FACE BLOCK GRADE AT SIDEWALK 2x6 PT FIR 4x4 PT FIR POSTS PEDESTRIAN LIGHT & ART ROCK (N.I.C.) 45% MITRE 0 CORNER 1x2 CEDAR 1x4 CEDAR 2x6 PT FIR 2x6 PT FIR SIMPSON C844 POST BRACKET 8'X8' CONC. SLAB W /LIGHT pROOM FIN. 2" DEPTH 3/4" MINUS CR. ROCK 12" DI A. POST FOOT"GS 0 3' -6" O.C. 7-77 an ZNN SOUTHEAST ELEVATION -- STREET VIEW NOR �4WEST ELEVATION — PARK VIEW CMU SIGN WALL ELEVATIONS DETAIL � SCALE: 1/2"=1'-0" CAP, SEE DETAIL ' 2x6 PT FIR /4" SPACE, T4- 1 /2" T p. \-.2x6 PT FIR FENCE ELEVAT;3N SCALE: 1/2' ; 1.— 0" CMU SIGN WALL TOWERS AT EA. END LIGHT FIXTURE (N.LC.) -,. ROCK ART SCULTURE (N.I.C.) WOOD SCREEN Q RESTROOM DETAIL SCALE: 1"=1`—()" CMU SIGN WALL LANDSCAPE GRADE AT BACK OF SIGN • LL — THREE METAL STRAP HINGES 2 x6 PT FIR METAL SLEEVE INBEDDED IN CONCRETE PAVEMENT c; /r. ASR 4 C A TE AT ENCLOSURE SCALE: , /2` TREAT ALL CEDAR SIDING WI 2 COATS OF CABOT SEMI — TRANSPARENT OIL STAIN 0 200 SQ. FT_ / GAL. APPLICATION 2x6 PT FIR CROSSBRACES V PUBLIC WORKS DEPARTMENT ENGINEp_INGswFEI;Is. wA1T;asEwIMAI4Ls4UuDING . aQJLLIMG f tlll "7 S. ettt Street Tacoma,. 'A/1 96402 7eirc (253)2 7220 racy (253)2 LIGHTING SCHEMATIC PLAN i 3 �` lacy �T SAW Trig. I / 1 i 1 i t I waft ►'= 20" - Ma este 3 "'41 'C • CALL UNDERGROUND UTILITY LOCATE SERVICE: 1-800-424-5555 2 DAYS BEFORE DIGGING 10' 20' 1 " =20 ,M FE • it c ! • Err J2 :: i r NO2°13'417 179, gg' i t t lege L5 .kaj. d a . ELECTRIC CONDUIT STUB —UP NOTE 2 J1 ELECTRICAL NOTES 1. THIS PLAN IS DIAGRAMATIC. CONTRACTOR WILL BE RESPONSIBLE FOR ELECTRICAL SYSTEM NECESSARY TO MAKE LIGHT FIXTURES AND OUTLETS FULLY FUNCTIONAL. 2. LIGHT FIXTURES AND LAMPS WILL BE BY ARTIST /ARCHITECT (NOT IN THIS CONTRACT). THIS CONTRACT SHALL BE RESPONSIBLE FOR PROVIDING WIRING FROM PANEL, COILED IN NEAREST J--BOX AND CONDUIT WITH PULL WIRE AS NECESSARY TO EXTEND WIRING FROM EACH J —BOX TO FIXTURE. AT FL1, FL2, & J2, J —BOXES SPOOL WIRE FOR L1, L2 /R2, & L4. SEE DETAIL 6/9. 3. NOTE THAT THERE IS A DUPLEX RECEPTACLE AND LIGHT IN ONE OF THE SUPPORTS IN THE GAZEBO AS NOTED ON THIS PLAN (L2 & R2). 4. LIGHT FIXTURES ARE 120V; 18 WATT FLORESENT LIGHTS, EACH ON IT'S OWN CIRCUIT. BOTH RECEPTACLES SHALL BE ON THEIR OWN CIRCUIT. 5. SEE ELECTRICAL EQUIPMENT SHOWN INSIDE CONTROLLER ENCLOSURE (DETAIL 4/9) ELECTRICAL CONTRACTOR SHALL PROVIDE POWER HOOKUP TO CONTROLLER. LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR LOW VOLTAGE WIRING TO IRRIGATION VALVES. 6. J —BOXES SHALL BE SEATTLE CITY LIGHT TYPE 1 & 2 J —BOXES AS NOTED. 7. PROVIDE 3" ELECTRICAL CONDUIT FROM CONTROLLER ENCLOSURE TO WITHIN 3' OF EXIST. POWER VAULT. COORDINATE W/ SEATTLE CITY LIGHT TO PROVIDE AND INSTALL THE LAST 3' INTO THE "LIVE" VAULT. SEATTLE LIGHT WILL INSTALL THE CONDUCTORS TO METER AND METER. PROVIDE 1" COMMUNICATION CONDUIT FROM EXISTING COMMUN. JUNCTION BOX TO CONTROLLER ENCLOSURE. RIM • L4 33 ELECTRIC CONDUIT STUB —UP NOTE 2 e D EXISTING APAR TMEN T e No273'41 "E 193.80' Um= ORO J1 ,R. U CON TROLLER ENCLOSURE FL2 7\ e 1 1 0 - - ..II........ M NMI O tl L3 T ; 37TH Vr COn\ PAt C. CONC. PAD CONC. PAD CONC. PAD CONC. PAD IIMM CONC. PAD 0 00 D NOTE 7 e J1 s ELECTRIC CONDUIT 9 STUB —UP NOTE 2 NO2°1-5'41"E 135.07' NOTE 2 FL1 L2 &R2 AIL ' ■ ti rake • STUB —UP L1 ELECTRIC CONDUIT STUB —UP ELECTRIC CONDUIT NOTE 3 td rN 0 0 00 i r r - w • e CONDUIT/WIRE SCHEDULE (2) 1" CONDUIT W/ (3) #10 CU & (1) #10 CU GRD. EACH & (1) 1" CONDUIT W/ PULL WIRE 1" CONDUIT W/ (2) #10 CU & (1) #10 CU. GRD. LEGEND J1 TYPE 1 JUNCTION BOX i J2 i LIGHTS (BY OTHERS)— L2 120V AC LIGHT FIXTURES R 2 F L� LIGHT ( B W/ PULL WIRES) • (1) 1" CONDUIT W/ (2) #10 CU & (1) #10 CU GRD. 1" CONDUIT W/ PULL WIRE STUBOUT 5-0" 1" CONDUIT W/ PULL WIRE STUBOUT TO FIXTURE LOCATION — L1,L2 /R2 & L4 - - ..:.: 4 CONTROLLER ENCLOSURE TYPE 2 JUNCTION BOX CONDUIT SIZE /NUMBER DESIGNATION LIGHT SYMBOL RECEPTACLES — 110V DUPLEX RECEPTACLES 1" CONDUITS CONDUIT TO FIXTURE ELECTRIC CONDUIT STUB —UP w/ PULL WRES FROM J —BOX Ire 4 TYPICAL COLUMN FOOTING TYPICAL BASE PLATE PRECAST COLUMN COLUMN ELEVATION GAZEBO PLAN SECTION AT LIGHT CANOPY ROOF PLAN AT GAZEBO PRECAST COLUMN TYPICAL COLUMN FOOTING TYPICAL COLUMN SECTION REVISIONS