Loading...
HomeMy WebLinkAboutPermit D03-098 - FIRESIDE - OFFICEFIRESIDE 13028 INTERURBAN AV SOUTH D03 -098 • Storm Drainage: Street Use: Water Main Extension: Water Meter: Channelization / Striping: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0004800017 Address: 13028 INTERURBAN AV S TUKW Suite No: Tenant: Name: FIRESIDE Address: 13028 INTERURBAN AV S, TUKWILA WA Contractor: Name: PRECISION BUILDERS INC Address: PO BOX 98609, DES MOINES WA Contractor License No: PRECIBI151C2 Public Works Activities: DEVELOPMENT PERMIT Owner: Name: AMB INSTITUTIONAL ALLIANCE Phone: Address: C/O MCELROY GEORGE & ASSOC, 3131 S VAUGHN WAY STE 301 Contact Person: Name: DAVID KEHLE Address: 12720 GATEWAY DR, SUITE 116, SEATTLE WA DESCRIPTION OF WORK: INSTALLING NON - BEARING TENANT WALL TO CREATE AN OFFICE. ** Continued Next Page ** D03 -098 Permit Number: D03 -098 Issue Date: 04/07/2003 Permit Expires On: 10/04/2003 Phone: 206 - 433 -8997 Phone: 206 878 -2948 Expiration Date: 01 /19/2004 Value of Construction: $4,000.00 Fees Collected: $164.96 Type of Fire Protection: SPRINKLERS Uniform Building Code Edition: 1997 Type of Construction: VN Occupancy per UBC: 0016 Curb Cut/Access /Sidewalk /CSS: Fire Loop Hydrant: Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Private: Public: Printed: 04 -07 -2003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: Date: I hereby certify that I have read and examine (his permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating cons uction or the perfor ance of work. I am authorized to sign and obtain this development permit. Signature: L at .A3 Pi .MAD Date: 4-- 7 - �C.J doc: Devperm Print Name: f) iJ/eD This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D03 -098 Printed: 04 -07 -2003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0004800017 Address: 13028 INTERURBAN AV S TUKW Suite No: Tenant: FIRESIDE 1: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: D03 -098 Status: ISSUED Applied Date: 03/26/2003 Issue Date: 04/07/2003 2: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 3: ** *FIRE EXTINGUISHERS * ** - UFC Article 10 and NFPA 10. 4: Maintain fire extinguisher coverage throughout. 5: The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B :C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) 6: Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. 7: Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 106.3) (UFC Standard 10 -1) 8: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 9: * ** EXITS * ** - UFC Article 12 10: No point in a sprinklered building may be more than 250 feet from an exit, measured along the path of travel. (UBC 1004.2.5.2.2) 11: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) 12: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) 13: Gates and barriers shall be openable without the use of a key or any special knowledge or effort. Gates and barriers in an exit shall not be locked, chained, bolted, barred, latched or otherwise rendered unopenable at times when the building or area served by the exit is occupied. (UFC 1208.2) 14: * ** SPRINKLER SYSTEMS * ** - UFC ARTICLE 10 - NFPA 13 15: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. 16: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions doc: Conditions D03 -098 Printed: 04 -07 -2003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 and under overhangs greater than four feet wide. (NFPA 13- 4- 5.5.3.1) 17: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 18: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 19: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 20: * ** BUILDING CONSTRUCTION * ** - (UFC, UBC) 21: When walls and ceilings are required to be of fire resistive or noncombustible construction, interior finish materials shall meet the requirements of Uniform Building Code 803. 22: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of the Uniform Building Code. (UBC 804.1) 23: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 24: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. ac Date: '�" / - O 3 Signature. 001.12 Print Name: [Y L OA3J1L -- ► a V &Y doc: Conditions D03 -098 Printed: 04 -07 -2003 LL nn ''. ,^, King Co Assessor's Tax No.: 000 - 001 1 Site Address: ( 3 O Z b I n T aUrb ar Atit Suite Number: I 1 Floor: Tenant Name: I 1 Y ---1 C)LL. II New Tenant: 0 .... Yes ( .No R 14 Property Owners Name: .S cu u / 0 b i ao ,y . Mailing Address: /c911 AD •- [�0.. - 1& �t.,i h r. 'OT Name: pall (Jk �'IC Mailing Address: ( 2-1 ZO GC.ted,ca9 k I I E -Mail Address: d h LPG) in Company Name: Mailing Address: Contact Person: E -Mail Address: Mailing Address: bo E -Mail Address: (tu eh (J (D .6.t ay) F;. own Contact Person: Company Name: Mailing Address: Contact Person: E -Mail Address: tapplicationstpennit application (1.2003) 1/2003 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** S. Page I Building Permit. No. Mechanical Permit No Public'Warks Permit O. ' City (For offke use only), WA State Day Telephone: ZUL • i-/ 8 Zip ,(J/1 961405 City State Zip Fax Number:�,d(v -� f2 X 3(M City Day Telephone: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** :ARCHITECT OF. . RECORD: -All plans must'be " Wet stamped .by:Architect of Company Name: Da P-40/1,Le i Aid) I ke-i- Lx1,�o �Cd &Da.1 .)rl tip ,6u (0 .(Li,-16e, l.)A 9B I Cpl City St''atte/e Zip Day Telephone: ,A61P - 'T 3 Fi9 Fax Number: A Ora- ENGINEER OF RECORD = All plans must, be wet stamped by Engineer of Record City Day Telephone: Fax Number: .,,. � y . � x f..t•.,i:... L"Ji�yt�wtF�,i.s"'i State State Zip Zip BUILDING :PERMIT INFORJ . I'ION- 206= 431 -3670 Valuation of Project (contractor's bid price): $ i 000 . Existing Building Valuation: $ Scope of Work (please provide detailed information): � nStC L Ji n non he tv ! 1'l -j-(:n ri-1 64) ell 2 G't.1e J it.n of hce , Will there be new rack storage? ❑...Yes )No If "yes ", see Handout No. for requirements. Provide All Building. Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑...Yes ❑ .. No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: X .. Sprinklers ❑...Automatic Fire Alarm ❑...None ❑ .. Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes .No If "yes", attach list of materials and storage locations on a separate 8 -1/2 .x I I paper indicating quantities a d Material Safety Data Sheets. UTILITY DISTRICTS: Note: If the utility district is not City of Tukwila, you must provide written verification and approval from that utility district at the time of permit application. Water ❑ .. City of Tukwila Water District ❑.. Water District it 125 0... Highline Water District 0... City of Renton Water District Sewer ❑ .. City of Tukwila Sewer District ❑ .. Val Vue Sewer District ❑...City of Renton Sewer District ❑...City of Seattle Sewer District ❑ .. Septic System (If property is served by a septic system, 2 copies of approved septic design from King County Health Department must be submitted at the time of permit application) \applications \permit application (I.2003) 1/2003 Page 2 Existing Interior Remodel Addition to Existing Structure New Type of Construction per UBC Type of Occupancy per UBC 1 Floor 3 6 2.. 120 5F V - I■J SF .1014. .5 2 " Floor 3 Floor Floors thru :. .'Basement Accessory Structure* Attached. Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck .. BUILDING :PERMIT INFORJ . I'ION- 206= 431 -3670 Valuation of Project (contractor's bid price): $ i 000 . Existing Building Valuation: $ Scope of Work (please provide detailed information): � nStC L Ji n non he tv ! 1'l -j-(:n ri-1 64) ell 2 G't.1e J it.n of hce , Will there be new rack storage? ❑...Yes )No If "yes ", see Handout No. for requirements. Provide All Building. Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑...Yes ❑ .. No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: X .. Sprinklers ❑...Automatic Fire Alarm ❑...None ❑ .. Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes .No If "yes", attach list of materials and storage locations on a separate 8 -1/2 .x I I paper indicating quantities a d Material Safety Data Sheets. UTILITY DISTRICTS: Note: If the utility district is not City of Tukwila, you must provide written verification and approval from that utility district at the time of permit application. Water ❑ .. City of Tukwila Water District ❑.. Water District it 125 0... Highline Water District 0... City of Renton Water District Sewer ❑ .. City of Tukwila Sewer District ❑ .. Val Vue Sewer District ❑...City of Renton Sewer District ❑...City of Seattle Sewer District ❑ .. Septic System (If property is served by a septic system, 2 copies of approved septic design from King County Health Department must be submitted at the time of permit application) \applications \permit application (I.2003) 1/2003 Page 2 { I `PUBLIC Scope of Work (please provide detailed information): Street Use: .. Street Use Land Altering and /or Hauling: ❑ .. Land Altering: ❑...Cut Storm Drainage: ❑ .. Storm Drainage ❑...Flood Control Zone Monthly Service Billing to: Name: Mailing Address: Water Meter Refund /Billing: Name: Mailing Address: \appliations\pcnnit application (1 -2003) 1/2003 RKS•.PERMIT INFG d[ATION 2206- 433;0179 ❑ ... Channel ization /Striping Water ... ❑ Sewer ... ❑ Call before you Dig: 1- 800 -424 -5555 ❑...Curb cut/Access /Sidewalk Please refer to Public Works Bulletin #1 for fees and estimate sheet. cubic yards 0... Fill cubic yards ❑ .. Hauling Sewer Information: ❑ .. City of Tukwila Sewer District ❑ .. Val Vue Sewer District ❑...City of Renton Sewer District ❑ .. City of Seattle Sewer District 0 .. Sanitary Side Sewer ❑ .. Sewer Main Extension ❑ ..Private ❑ .. Public Water Information: ❑ .. City of Tukwila Water District ❑ .. Water District #125 ❑... Highline Water District ❑...City of Renton Water District ❑ .. Water Main Extension 0.. Private ❑...Public 0 .. Water Meter/Exempt: Size(s): ❑ .. Deduct 0... Water Only ❑ .. Water Meter Permanent #: Size(s): ❑ .. Water Meter Temporary #: Size(s): ❑ .. Est. Quantity: gallons 0 .. Fire Loop/Hydrant (main to vault) #: Size(s): ❑ .. Landscaping Irrigation ❑ .. Miscellaneous: Page 3 Day Telephone: City State Sewage Treatment ❑ Fire Line .... ❑ Zip Day Telephone: City State Zip !ix4i•e .:v:•.v:ti.�.•_ .,-:;: 3::' a�:§ i=.t':..t;.;:w:::t.;:..� =�i.u: Unit Type: Qty Unit. Type: Qty Unit Type: .Qty ' Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm /Ind MECHANICAL CONTRACTOR INFORMATION Company Name: / Mailing Address: City state Zip Contact t t P Day Telephone: Z E -Mail Address: Fax Number: Z Contractor Registration Number: Expiration Date: t * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** J U 0 N D Lai J WO • yy g u_ ▪ d W Z = I— O W ui U� 0- O I-- U.1 W H - �O .Z W U = O ~ z Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New .... J Replacement .... 0 Commercial: New .... Replacement ....0 Fuel Type: Electric 0 Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES: Applicable Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: Print Name: rDcwi X Le.. Day Telephone: ZO(- 4� —a qq.1 Mailing Address: / a lleak) � Q,ieczJ(j fir, 6ui k / 1(0 r O LL W/t 96/(08 JJ City State Zip Date Application Accepted: \applications \permit application (I -2003) 1/2003 OA AGENT: to all perthits; in this application Date Application Expires: Page 4 Date :0 k C Staf •'fiats: s oeRvA.:„Yiio , 40 , , riwnv:;.ri ;.rArta y.n �rlN�•.;r q- Mn .y,ti� ; *3.r,. , , „ n+ rin; +'Y;=.:..' °Tt ".'r,.q;";'.t? fist. 9F§'Y,`.i.;4` .,'?!'M': ,' . Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: ACCOUNT ITEM LIST: Description doc: Receipt Payment City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 0004800017 13028 INTERURBAN AV S TUKW FIRESIDE R03 -00433 SKS 1165 DAVID KEHLE ARCHITECT TRANSACTION LIST: Type Method Description Check 15504 BUILDING - NONRES STATE BUILDING SURCHARGE RECEIPT Account Code 000/322.100 000/386.904 Permit Number: Status: Applied Date: Issue Date: Amount 101.75 Current Pmts 97.25 4.50 Total: 101.75 D03 -098 APPROVED 03/26/2003 Payment Amount: 101.75 Payment Date: 04/07/2003 02:54 PM Balance: $0.00 7402 04/09 /716 TOTAL 724.94 Printed: 04 -07 -2003 Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 0004800017 13028 INTERURBAN AV S TUKW FIRESIDE R03 -00397 BLH ADMIN DAVID KEHLE ARCHITECTS TRANSACTION LIST: Type Method Description Payment Check 15485 PLAN CHECK - NONRES RECEIPT Account Code 000/345.830 Permit Number: Status: Applied Date: Issue Date: Amount 63.21 Current Pmts 63.21 Total: 63.21 D03 -098 PENDING 03/26/2003 Payment Amount: 63.21 Payment Date: 03/26/2003 03:03 PM Balance: $101.75 7042 03/27 9716 TOTAL 1341..46 Printed: 03 -26 -2003 PERMIT NO.: 3 " `18 BUILDING PERMITS INSPECTIONS ❑ 1 Progress Inspection Status ❑ 2 Pre - construction ❑ 3 Investigation ❑ 4 OK to Occupy ❑ 5 Remove Stop Work Order ❑ 6 Follow -up ❑ 7 Pre -Move Inspection ❑ 50 WSEC Residential ❑ 60 WA Ventilation /Indoor AQC ❑ 70 NLEA Inspection/Modular Struct ❑ 71 Mobile Home Tie Down Insp ❑ 72 Marriage Lines ❑ 90 Resteel ❑ 95 Footing Drains ❑ 100 Foundation Footings ❑ 200 Foundation Walls ❑ 250 Foundation Insulation ❑ 300 Concrete Slab /Slab Insulation ❑ 350 Crawl Space ❑ 400 Shear Wall Nailing ❑ 450 Plywood Wall Sheathing ❑ 500 Roof Sheathing Nailing ❑ 525 Plywood Deck Nailing ❑ 550 Exterior Wall Sheathing ❑ 600 Masonry Chimney 610 Chimney Installation /All Types 700 Framing ❑ 750 Roof /Ceiling Insulation ❑ 800 Floor Insulation ❑ 801 Wall Insulation ❑ 802 Exterior Roof Insulation ft 803 Glazing Inspection ❑ 815 Lighting and Controls 900 Suspended Ceiling 1000 Interior Wallboard Fastening ❑ 1001 Exterior Wallboard Fastening ❑ 1110 Pre -Move Inspection ❑ 1115 Motor Inspection ❑ 1120 Pre -Demo ❑ 1140 Pre - reroof 1400 Final -Fire 1700 Final - Building 1900 Final - Reroof ❑ 3100 Site Visit ❑ 4000 Special- Concrete ❑ 4001 Special -Bolts in Concrete ❑ 4001 Special- Mom /Resist Conc Frame ❑ 4003 Special -Reinf Steel Prestress ❑ 4004 Special - Welding ❑ 4005 Special- High - Strength Bolting ❑ 4006 Special- Structural Masonry ❑ 4007 Special -Reinf Gypsum Concrete ❑ 4008 Special- Insulating Conc Fill ❑ 4009 Special -Spray Fireproofing ❑ 4010 Special - Piling, Piers, Caissons ❑ 4011 Special- Shotcrcte ❑ 4012 Special- Grading, Excav/Fill ❑ 4013 Special - Retaining Wall ❑ 4014 Special- Panels ❑ 4015 Special -Smoke Control System TENANT NAME: h R'" .5' CONDITIONS _4 10001 No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division 10002 Plumbing permits shall be obtained through King Co 10003 Electrical permits obtained through L & I 10004 All mechanical work shall be under separate permit 10005 All permits, insp records & approved plans available ❑ 10006 All structural concrete shall be special inspected ❑ 10007 All structural welding shall be done by WABO certified inspector ❑ 10008 All high- strength bolting shall be special inspected ❑ 10009 Bolts installed in concrete shall be special inspected ❑ 10010 When special inspection is required...notify Tukwila Building Division ❑ 10011 The special inspector shall submit a final signed report ❑ 10012 Any new ceiling grid and light fixture installation ❑ 10013 Partition walls attached to ceiling grid ❑ 10014 Readily accessible access to roof mounted equipment ❑ 10015 Engineered truss drawings & calcs shall be on site ❑ 10016 Any exposed insulation backing material shall have ❑ 10017 Subgrade preparation including drainage, excavation ❑ 10018 A statement from the roofing contractor verifying fire retardant class of roof 4 10019 All construction to be done in conformance w /approved plans ❑ 10020 Structural observation shall be provided for this project ❑ 10021 All food preparation establishments must have King Co ❑ 10022 Fire retardant treated wood shall have flame spread of ❑ 10023 Notify Building Division prior to placing any concrete ❑ 10024 All spray applied fireproofing shall be special inspected ❑ 10025 All wood to remain in placed concrete shall be treated 10026 All structural masonry shall be special inspected 10027 Validity of Permit 10028 Rack storage requires separate permit ❑ 10030 No occupancy of building until final insp by Bldg Div ❑ 10031 Comply with requirements of TMC 16.04 ❑ 10032 Remove all weeds, concrete, stone foundations, flat concrete ❑ 10034 Removal of septic tanks require approval and compliance with King Co Health Dept. ❑ 10035 Contact PW Div to obtain insp for water /sewer connect ❑ 10036 Manufacturers installation instructions required on site ❑ 10038 A C of O will be required for this permit ❑ 10039 Final approval for all TI w /in the limits of the SC Mall 10040 All construction noise to be in compliance with 8.2 TMC 10041 Ventilation is required for all new rooms & spaces ❑ 10042 Fuel burning appliances ❑ 10043 Appliances, which generate ❑ 10044 Water heater shall be anchored ❑ 10045 Reroof ❑ "Anchoring — All new construct and substantial improvement shall be anchored to prevent flotation" Plan Reviewer: Permit Tech: Date: , Date: 4-i itiuxrrAiaTst 4 s! Project: Fire Si Type of Inspection: IV-/ �/ Ad e s t $ �Lv�- f�vrl "Av Date Called: 3610 3 Special Instructions: f' �f (..4." 5/41 ffl • 6VlfC`! v Date Wanted: i i /� a.m.. p.m. Requester: 5/// Phone N (fi — 31& -5& 7 ? "u�N5a`k:7ii1?, )e. ✓»tS ' rit,:di Zy r.:;: `)alhi„ci »F.�.L'tCi�;a; §iL INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COM ENTS: nsp; tor: 47.00 REINSPECTIO4 FEE REQ aid at 6300 Southcenter Blvd., S, Receipt No.: INSPECTION RECORD Retain a copy with permit Dc?-0qF Corrections required prior to approval. Date: Date: ( RED. Prior to inspection, fee must be ite 100. Call to schedule reinspection. ':-Project Name Address / -3oa _......:Y...-„„Retain_current inspection ,schedule_ Needs shift inspection Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature City of Tukwila Fu eS; Approved without correction notice Approved with correction notice issued • FINALAPP.FRM Rev. 2/19/98 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Steven M. Mullet, Mayor Fire Department Thomas R Keefe, Fire Chief Permit No. 00 3-9? Date Suite # /2C - 3 o T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 e e, ode ee .• ee,..,:;.*A1,1,..44.,..• le.e.4,14.1...1..:Yele.1.1...U.:-.ei • •ceeSs:Iiief.,:eage..tee,er.i....2 1'm...4 141-:«Ies).4eie. Project • r1` SI��� Type of Ins p ction:. , y/ (.(1 �� O Address /3G 231 _in- lfruivmi/ f1 / ... Date Called ��` C 3 Special Instructions: Date Wantegi J, ) / / • p .m. Requester: / Phone . _ /5 30 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION NO. INSPECTION RECORD Retain a copy with permit (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector* Date: El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: V ‘1.e, s 4 Type of Inspection: - r6 rill ''n(1 A ¢ ass• Date Called,: Special Instructions: Date Want . 17 03 p.m. Requester: Kt leL( Phone No: 0 (0� --1910 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: ( tAicLfa r -sue Date: f 1 / Receipt No.: Date: INSPECTION RECORD Retain a copy with permit 903-Mg PERMIT N Approved per applicable codes. J Corrections required prior to approval. X1-411 $47.00 REINSPt CTION FEE RE,Q UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd(, Suite 100. Call to schedule reinspection. Project Info Project Address rt VE1 ❑ Less than 60% of the fixtures are new, and installed lighting wattage is not being increased Dater 202, h iv) �m rC �/� , I � FvN� tl -1, rt '1V P,i ,- luDs'f Fo Building DeoartmenD se CIIY MAR j 6 / ()(1, PERMIT CENTER Open Parking Applicant Name: I � 117 � r� -t �' *Ritzy— t � Applicant Address: Z1/2, 0 _ / , 1/ r� ,_ ika �j ''/CsI'� Applicant Phone: //t16 _ 6 1 .2 - ' A II, Alteration Exceptions (check appropriate box) No changes are being made to the lighting V003H �DI ❑ Less than 60% of the fixtures are new, and installed lighting wattage is not being increased Location (floor /room no.) Occupancy Description Allowed Watts per ft Area in ft 7 Allowed x Area Covered Parking C '1V P,i ,- luDs'f Open Parking 0.2 W /ft Outdoor Areas 0.2 W /ft` Bldg. (by facade) 0.25 W /ft Bldg. (by perim) 7.5 W /If " From Table 15 -1 (over) - document all exceptions taken from footnotes Total Allowed Watts Location (floor /room no.) Fixture Description Number of Fixtures , , Watts/ Fixture Watts Proposed Covered Parking C '1V P,i ,- luDs'f Open Parking 0.2 W /ft Outdoor Areas 0.2 W /ft` Bldg. (by facade) 0.25 W /ft Bldg. (by perim) 7.5 W /If Note: for building exterior, choose either the facade area or the perimeter method, but not both) Total Allowed Watts .,..,..........;.:7:: Total Proposed Watts may not exceed Total Allowed Watts fortfliWon:'' : "'" ``'' ' Total Proposed Watts Location Description Allowed Watts per ft or per If Area in ft (or If for perimeter) Allowed Watts x ft (or x If) Covered Parking 0.2 W /ft Open Parking 0.2 W /ft Outdoor Areas 0.2 W /ft` Bldg. (by facade) 0.25 W /ft Bldg. (by perim) 7.5 W /If Note: for building exterior, choose either the facade area or the perimeter method, but not both) Total Allowed Watts p Number of Watts/ Watts Location Fixture Description Fixtures Fixture Proposed Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts 1994 Washington State Nonresidential Energy Code Compliance Forms 1994 .vashin ton State Nonresidential Ener Code Com•liance Form Lighting Summary • • LTG-SUM Project Description I g New Building ❑ Addition Maximum Allowed Lighting Wattage (Interior) %Alteration Compliance Option ❑ Prescriptive ❑ Lighting Power Allowance ❑ Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) FILE COPY Proposed Lighting Wattage (Interior) (May not exceed Total Allowed Watts for Interior) Maximum Allowed Lighting Wattage (Exterior) Pro osed Lighting Wattage (Exterior) (May not exceed Total Allowed Watts for Exterior) Page 17 agorepOOMONMattlMaroppoorexammiso j?'S�'::".,"•1 ?;?iY !{i;�h , <r1.5�,r:}J;y}5y;: ! %uMsty ;3;�",!;:.•. Second Edition . June 1995 1994 Washington State Nonresidential Energy Code Compliance Forms 1994 .vashin ton State Nonresidential Ener Code Com•liance Form Lighting Summary • • LTG-SUM Project Description I g New Building ❑ Addition Maximum Allowed Lighting Wattage (Interior) %Alteration Compliance Option ❑ Prescriptive ❑ Lighting Power Allowance ❑ Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) FILE COPY Proposed Lighting Wattage (Interior) (May not exceed Total Allowed Watts for Interior) Maximum Allowed Lighting Wattage (Exterior) Pro osed Lighting Wattage (Exterior) (May not exceed Total Allowed Watts for Exterior) Page 17 agorepOOMONMattlMaroppoorexammiso j?'S�'::".,"•1 ?;?iY !{i;�h , <r1.5�,r:}J;y}5y;: ! %uMsty ;3;�",!;:.•. Second Edition . June 1995 irfsUlatcn ntenc f l[,'i U? ac Cr asluu. t- Insulation on ex or integral - maximum U- factor is 0.25 If project qualifies for Concrete:Masonry with HC >_ 9.0 Bturft'•'F below (other walls Opaque Wall requirements). Use descriptions from Table 20 -Sb in the Code. Option, Is 'malts must meet a'rid values 1 U-faclor ; Wall Description (including insulation R -value & position) Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Wall Area if they are insulated to the level required for opaque walls. Total Glazing Area (rough opening) (vertical & overhd) divided by All Other Roofs times 100 ecuals ;4 Glazing 7 o ('NN - i ; tv�i4 . Opaque Walls X ^ 00 = X t Concrete/ Masonry Option • Floors Over Unccncitioned Space Slabs -on -Grade Radiant Floors Maximum U-fac:crs Cpacue Doors I Envelope Requirements (enter values as acplicable) Fully heated/cooled space Minimum Insulation F- values Roofs Over Attic Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Wall Area if they are insulated to the level required for opaque walls. Total Glazing Area (rough opening) (vertical & overhd) divided by All Other Roofs times 100 ecuals ;4 Glazing _ Opaque Walls X ^ 00 = X t Concrete/ Masonry Option Below Grade Walls Floors Over Unccncitioned Space Slabs -on -Grade Radiant Floors Maximum U-fac:crs Cpacue Doors I Vertical Glazing Cvemead Glazing I Maximum SHGC (or SC) Vert:cai/Overhead Glazing I Space Heat Type ❑ E!ecthc resistance ❑ All other (see over for definitions) Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Wall Area if they are insulated to the level required for opaque walls. Total Glazing Area (rough opening) (vertical & overhd) divided by Gross Exterior Wall Area times 100 ecuals ;4 Glazing _ X ^ 00 = X t Concrete/ Masonry Option ❑ Check here if using this option and if project meets all requirements for the ConcreteiMasonry Cption. See Decision Flowchart (over) for qualifications. Enter reouirements for each qualifying assembly in the table below. Semi - heated space' Notes: 994 Washinaton State Nonresidential Enera Code Comoliance Form ummary Climate Zone 1 ENV-SUM ential Energy Coee Compliance Forms oject Address i Applicant Name: Applicant Address: Applicant Phone: 1 A Lp .r /'- 7 IC ,Vintmum lnsulaacn F- values Reefs Cver Semi - Heated Scaces' I 'Refer to Section 1310 fcr qua:ificarcns arc requirements Date aze For Building DefalefittilfIse CITY OF TUKWILA MAR 2 6 2003 PERMIT CENTER April, 1994 Project Description ❑ New Building Q Addition IgAlteration ❑ Change of Use Compliance Option ❑ Prescnptive ❑ Component Performance (See Decision Flowchart (over) for qualifications) ❑ ENVSTD ❑ Systems Analysis Op aque Concrete/Ma sonry Wall Requirements i mdersta • FILE COPY TO c?8 Sr 1xrx 4*S� fiFas7Lr: it3 = 1 ax h txc w rtRMl7' dOR C�pY' PLAN REVIEW C /RSOTING SLIP ACTIVITY NUMBER: D03 -098 DATE: 03 -27 -03 PROJECT NAME: FIRESIDE SITE ADDRESS: 13028 INTERURBAN AVENUE SOUTH X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: r, Building -1-g PubliV Fire Prevention Structural ❑ 8t 4 44-0 Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04 -01 -03 Complete d Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Ec Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04 -29 -03 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PERMIT COORD COPY • ".'.k:�;is.:y't: i Kix" 4'' r? u:'+ :xsCikG:' 2i16yY • ,"1�.'<.t` , Oct 10 02 0'7:23• 19t.'1•.K2070 ('W74 ec re<5idW — $01,15 X03 -0�8 ChurAlcaor J\jiic€L FA;14►134 x: 1 !1.' 47 ) CONST CONT GEN ' ';; REGIST. gC01,.;•- AREC BI151C2 01/i9/2004 r+'$ECZ'IMX DAT¢ •rp2 j 1985 BRECISION BUILDERS INC PO BOX 98609 DES MOINES WA 99198 -0609 DEPARTMENT OF LABOR AND NIA:STR /ES REGISTERED AS PROVIDED BY LAW AS L. ERAL Oct ; :el! An.' I) ?,i414tq ;'cniti_c;tc REGISTERED AS PROVIDED BY LAW AS CONST CONT GENEP.L REGIST. # EXP. DATE CC01 PRECIBI1E1C2 01/19/2004 EFFECTIVE DATE 42/22/1935 PRECI S TOW Wit:DI RS :a%: PO BOX 98609. DES MOINES WA 98198 -0509 St I';aucd h y )?FPARTM'?NT CF LABOP. ANIJ INDUS T RI .5 0967 zOOZ c .130 Please. Remove And Sign - IdentiflCation Card Deem. Placing In Billfold • p•2 _••m• Oat 10 02 07:23a d ecision Builders, Inc. 20.- 078 -0SG7 F4 4 »34H,:µ Y» • 191: i.. f524NAt 0t/97: DEPARTMENT OF LABOR AND NDLSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL ; • -• RBG I 83` # : , a;c EXP st :,DATE 9C01.. i4tECZB2181C2 01/19/2004 4F$ECTXMA DAT¢1;1;;i }' r0.2/2 PRECISION BUILDERS INC ; PO BOX 96609 DES MOINES WA 99198 -0609 - .kt.:%:I An:.! I)3., Iaq I REGISTERED AE PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # EXP. DATE CC01 PRECIBI181C2 01/19/2004 EFFECTIVE DATE 02/22/1995 PRECISION BUILDERS I1Q.", PO BOX 98609 DES MOINES WA 98198 -0609 tit } nature 1•;;itcti by nEPARTN OF LABOR .ANL1 :NDUSTRI .S .1.O1JJH08V `31 11 >1 n?RVQ ZOOZ c ! 100 Must' Rernovc And Sign tdentili cad on Ca I'd Ptucing In Bil 11'Old p. ......•.�........vw».ur.. n. iu.: ulu ?./- ti:+P:Gk.:..Yt2.A_:�x,�'; ti B LC (: A[0 POP' FINS. gGE Cs C CS IdC !' t'.x •-' : b-' 5•wtliC...=RI ,yes. : 3E:: x =" 3:.6 5G s+ FC1R OF°Y2 5P Aa 596 3C F :..'IRE.CUSE SP AcE o„ti.F4N Lam: X0 • IiAi - -L` f l (_EE•BR mAtCLES . SEE .•.: -: . 3' , 8 SOLD JOCK DCCR ..'£.► .ATE yr PAR B. 3 5+...PVCER5 . _ FOP DOOR E EXS'' G DOC• `al: MORK 4 u__ I. �F1M11111111-II ii a iiIIIIIIMIIIIIIIIIIIIII ■__ "fp. IMIS. /NM MIN IrIll MM. ---11111/ 1 — 1/ INNIIIW MI I =Nom Er slaw iliv mom 14 m IN W illi rW illiill ocaid 0 wI 30' TI GATEWA'r CORPORATE CENTER BUILDING AN 1 BOOR BAM Cu DO 21' a Er''`1NG Cam' : Pa14 3"p EC REBER Er 1MG 5uS= acaenc4. Asr RE°AR "..).r +Ge' c : Art Rte_ aCE DAMAGE: '..ES 5' IC' 15 , SCALE 1/8" • I' -0" ME TE 5041nILE og, 4 GLASS I+ "ETA►. EA.. • 3 S-xF ,p' �y�y� 5.31-DING �� M CiaAPCf 'O EX'SMG NW- OPE 2) L ICsr•lIG EXB,'" - LESS ''«Ea 6" OF c X'i11f5 les APD P6'&. $M." & '5' ' arm NAB 25' 35' 4 a V O • 30' pc OFFICE EXISTING M 'O iIP*.s4 E W NG '0 t'!E fleCVM .. � wt. 6' ' E''4 5"l3 t � AT 24' OC Ir 4 54' a`rP EC ON FAO. 5CE TO 5'RL'J?k OLPCs ' ' 1 1A'O.4 EX1STp � , e, 3 ' . r '£A Sit I A_ AT 24. O !► +E ' AS REOI TO ec—' IDeS'1MG CE1L oa 5 V GY• eC ON EIG: 50E Det4 Do R EX1ST6G DOOR l i 5 GATEWAY CORPORATE CENTER: BOLDING 8 r x 8 EXISTING 2 -TWEE FLUORESCENT IU4'75 / 2' x 4' EXISTHG 3 -11.1BE FLUORESCENT (88 iiiATTS) 2' x 4 EXlST11ri 3 -TUBE FLUORESCENT TO BE RELOCATED !88 3tAT's1 1 < 2' x 4 NEW OR RELOCATED 3 -T1EE FLUORESCENT (88 IiiATTS' V ., EXISTING RESTROOM LIGHT IL irit rA/ED E)( NO O DUPLEX OUTLET 120W O FOUI2PLEX OUTLET 2mW A WALL TELEP4IO E OUTLET,11DRING. CONDUrT, AND PULL STING ONLY $ ELECTRIC 5IUTCI- EX OFFICE O D03 SAMMY 111WOUITE CENfEtt halmL NM= VIeINITY !IAP Sca NOT TO Si n" WurC P.ATTS IDE EA. 50 51DE WALL • 50114D WALL I � BLOCK • GRID FOAM TAPE • WALL PANT EXTERIOR FLAT BLACK - -- , ATTACH BOTTOM TRACK TO CONC. FLOOR W/ POWDER DRIVEN ANCI4OR5 AT 24" O.C. 2 I/2" RUBBER BASE • CARPET WALL SECTION O SCALE: 1 -1/1' • 1' -0' Art WOOD DOOR HOLLOW METAL DRY WALL FRAME 5/8" GYP. BD. BON SIDES STEEL STUDS 4 " or— or-9 RIOR DOOR JAMB 03/25/2003 5:08 pm FOR WADS GREATER Ti-IAN 8 0' N VON ''ITNOUT Alm IN WALL PROVIDE t29 . WIRES SPLAYED •4 =' TO AN EYE SCREW • TO OF WALL CO NT. METAL TRIM. FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance Receipt of con- tractor's ccpy of approved plans acknowledged. B fi ',L. Date Permit No. �+ r 5/8' G. BD (TYPE 7t' • FIRE RATED WALL5.) ACOU5T1CA, BLANKET • SOUND UAL. CAULK GYP. BD. TO FLOGQ • ALL SCtJID AND tNSUL. WALLS A RE c, )F WORK I E NDER THIS PERMIT NO CHANCiGF3 SHALL BE 'h$. - " T" TO THE SCOPE OF WORK WIT O T PR OR / ROVAL OF TUKW1A 6UII.DING OTE: FIEVIStOtSS WILL PEOv'RE 4 mu PiAM SiiP - SEPARATE PERMIT REQUIRED FOLL Le MECHANICAL E LECTRICAL JMBING tAS PIPING CITY OF TUKWILA BUILDING DIVISION SECTION SEC ?ION RECEIVED `'ITV OF TIIKWiLA PERMIT CENTER X03 -098 CI \CAD \8704 -8 \FIRESIDE \T -lnew +0! CC) 0) CO CO M N v W ALA. U) d z o f CV' r). ." CO 5 o z wIa gz N �3 wuj g co ^ W `` Vim