Loading...
HomeMy WebLinkAboutPermit D03-110 - APOLLO SPAS - STORAGE RACKSD03 -110 Apollo Spas 1233 Andover Pk. E. Z i-Z w. 00 W=. w 0 2 g J, u_ =• a F- _ Z� Z0 w o52 o I- w W wZ U =, O~ z Water Main Extension: Water Meter: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3523049084 Address: 1233 ANDOVER PK E TUKW Suite No: Tenant: Name: APOLLO SPAS Address: 1233 ANDOVER PK E, TUKWILA WA Owner: Name: BINAF INVESTMENTS Address: 16400 SOUTHCENTER PARKWAY #204, TUKWILA WA Contact Person: Name: CHRISTIAN BALSCH Address: 1233 ANDOVER PK E, TUKWILA WA Contractor: Name: OWNER AFFIDAVIT IN FILE Address: , Contractor License No: DESCRIPTION OF WORK: MODIFY EXISTING RCKS TO LIMIT HEIGHT AVAILABLE TO STROAGE TO BE BELOW 8 FEET MAXIMUM HEIGHT. Value of Construction: $ $0.00 Fees Collected: $118.76 Type of Fire Protection: SPRINKLERS /AFA Uniform Building Code Edition: 1997 Type of Construction: RACKS Occupancy per UBC: 0025 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N DEVELOPMENT PERMIT Permit Number: D03 -110 Issue Date: 05/07/2003 Permit Expires On: 11/03/2003 Expiration Date: Phone: Phone: 206 - 575 -2700 Phone: Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: N Storm Drainage: N Street Use: N Profit: N N N Private: N 003 -110 Public: N Non - Profit: N Public: N Printed: 05 -07 -2003 :,�Lt.Y;yt:l.it:ti {i�:s t y F:�i z I z mo w . aa = J U O 0 CO ILI J i— a l 2 L? CD a w z I - I- 0 z � w U 0 O - O 1— w • w .. z w = z Signature: Print Name: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: _. ; 72 e'a �c /� e- - c_.._- Date: — 7--,3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will •e complied with, whether specified herein or not. The granting of this permit . •: . presum - o s ive authority to violate or cancel the provisions of any other state or local laws regulating construction • the rmance •f w• k. I am authorized to sign and obtain this development permit. v ` Date: 0 C cr3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D03 -110 Printed: 05 -07 -2003 Parcel No.: 3523049084 Address: 1233 ANDOVER PK E TUKW Suite No: Tenant: APOLLO SPAS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 4: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 5: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 6: Subject to field inspection. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of th'_ per it -s not presu • - o give authority to violate or cancel the provision of any other work or local laws regulating constr}dction o performan - of ork. Signature: -- (4 Date: 0 Vk Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS D03 -110 Permit Number: D03-110 Status: ISSUED Applied Date: 04/15/2003 Issue Date: 05/07/2003 Printed: 05 -07 -2003 Site Address: 1 ,4 AWN •RA Tenant Name: MD I, S p Property Owners Name: M(ltli PeT&%in Mailing Address: lki vA CONTAC'1~:P Name: Mailing Address: ( 3 todwef far. task E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: 'applicauonsvennn appticauon t 1.20031 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** C6A Cakeict uatc ik,„t1b c¢y King Co Assessor's Tax No.: Suite Number: City Day Telephone: fu taco City Fax Number: City 20c Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT, OF RECORD -All plans must be wet stamped by Architect of Record . • Contact Person: E -Mail Address: •{ :5 CJo New Tenant: [ .... Yes D..No State Zip wA War State Zip -5/c231 0 State Day Telephone: Fax Number: City Day Telephone: Fax Number: State State • Floor: Zip Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Zip City Day Telephone: Fax Number: BUILDING PERMIT INFORMA'A A ON-2O6-431-367O. — Valuation of Project (contractor's bid price): `$ n Scope of Work (please provide detailed information): m b Will there be new rack storage? X.. Yes ❑ .. No If "yes ", see Handout No. 'apphatwns'.pmnit application 0.2003) 1.200) Page 2 Existing Building Valuation: $ U for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑...Yes ❑ .. No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: b ill . Sprinklers 4...Automatic Fire Alarm ❑...None ❑.. Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ...No If "yes", attach list of materials and storage locations on a separate 8-1/2 x 1 l paper indicating quantities d Material Safety Data Sheets. UTILITY DISTRICTS: Note: If the utility district is not City of Tukwila, you must provide written verification and approval from that utility district at the time of permit application. Water ❑ .. City of Tukwila Water District ❑.. Water District #125 ❑... Highline Water District ❑... City of Renton Water District Sewer ❑.. City of Tukwila Sewer District ❑.. Val Vue Sewer District ❑...City of Renton Sewer District El ...City of Seattle Sewer District ❑ .. Septic System (If property is served by a septic system, 2 copies of approved septic design from King County Health Department must be submitted at the time of permit application) Existing Interior Remodel Addition to Existing Structure New Type of Construction per UBC Type of Occupancy per UBC I' Floor k 2 ' Floor 3f Floor Floors • thru Basement Accessory Structure * Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMA'A A ON-2O6-431-367O. — Valuation of Project (contractor's bid price): `$ n Scope of Work (please provide detailed information): m b Will there be new rack storage? X.. Yes ❑ .. No If "yes ", see Handout No. 'apphatwns'.pmnit application 0.2003) 1.200) Page 2 Existing Building Valuation: $ U for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑...Yes ❑ .. No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: b ill . Sprinklers 4...Automatic Fire Alarm ❑...None ❑.. Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ...No If "yes", attach list of materials and storage locations on a separate 8-1/2 x 1 l paper indicating quantities d Material Safety Data Sheets. UTILITY DISTRICTS: Note: If the utility district is not City of Tukwila, you must provide written verification and approval from that utility district at the time of permit application. Water ❑ .. City of Tukwila Water District ❑.. Water District #125 ❑... Highline Water District ❑... City of Renton Water District Sewer ❑.. City of Tukwila Sewer District ❑.. Val Vue Sewer District ❑...City of Renton Sewer District El ...City of Seattle Sewer District ❑ .. Septic System (If property is served by a septic system, 2 copies of approved septic design from King County Health Department must be submitted at the time of permit application) PUBLIC WORKS PERMIT INFO "MATION 206 -433 -0179 Scope of Work (please provide detailed information): Street Use: ❑ .. Street Use Land Altering and /or Hauling: ❑ .. Land Altering: 0...Cut `applieationatpermit application (1.2003) 11:003 ❑... Channelization /Striping Storm Drainage: ❑.. Storm Drainage ❑...Flood Control Zone Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. cubic yards ... 0... Curb cut/Access/Sidewalk cubic yards ❑ .. Hauling Sewer Information: ❑ . City of Tukwila Sewer District p .. Val Vue Sewer District p... City of Renton Sewer District ❑ .. City of Seattle Sewer District .. Sanitary Side Sewer ❑.. Sewer Main Extension ❑ .. Private Q.. Public Water Information: ❑ .. City of Tukwila Water District ❑ .. Water District #I25 ❑... Highline Water District 0... City of Renton Water District ❑.. Water Main Extension 0.. Private ❑...Public ❑ .. Water Meter/Exempt: Size(s): ❑ .. Deduct ❑ ... Water Only ❑ .. Water Meter Permanent #: Size(s): ❑ .. Water Meter Temporary #: Size(s): ❑ .. Est. Quantity: gallons ❑ .. Fire Loop/Hydrant (main to vault) #: Size(s): ❑ .. Landscaping Irrigation ❑ .. Miscellaneous: Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water ... ❑ Sewer ... ❑ Sewage Treatment ❑ Fire Line .... ❑ Water Meter Refund/Billing: Name: Mailing Address: City state Zip Page 3 Day Telephone: 4i�1`dn! ^iif'r�F Unit Type: Qty . Unit Type: Qty . Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace >I00K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <=10,000 CFM Incinerator — Comm/Ind MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): S Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement ....0 Commercial: New ....0 Replacement ....0 Fuel Type: Electric [] Gas ....Q Other: Indicate type of mechanical work being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Appl' ions for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend e me for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the ifor Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY TH PENALTY OF PER.I B BUILDING 0 R OR A ENT: Signature: Print Name: N Mailing Address: Date Application Apted: ',ppitutIonskpermtl application (I -3UO)) 1 :00) ' 15'003 AVE READ AND XAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER LAWS OF TH ATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: 04 3 — ) 1 C (1 3 Day Telephone: 1-.0C 51c (:I IS UL Date Application Expires: /o /5 -o3 Page 4 Sta���itals: TN,A, t. '*.. tt s. 46 0 SCALE r-I4Cr • ',A sot.01 180TH STREET • • ' t.,:m.r.=.0.1‘00.11LIMIRM.12C0.17.;iiatalga= PARCEL NO 352304-90Si 15' unun-- EASEMENT 0 INTERSECTION STA. 723+42.20 S. 180TH ST - STA. 301+47.15 ANDOVER PARK EAST ••••••••■■■••••••■• • EXHIBIT 'B' Sidewalk Easement Conveyance \-s (IV 11 N p - prt)N_.0 0 • ' t91 OA , 0.0 , r,l , t71. F1ECEIVEb CITY OF TUKWILA APR 1 5 2003 PERMIT CENTER Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: TRANSACTION LIST: Type Method doc: Receipt Payment City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 3523049084 1233 ANDOVER PK E TUKW APOLLO SPAS R03 -00464 BLH ADMIN ACCOUNT ITEM LIST: Description CHRISTIAN BALSCH Check Description 2598 BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE RECEIPT Account Code 000/322.100 000/345.830 000/386.904 Permit Number: Status: Applied Date: Issue Date: Payment Amount: 118.76 Payment Date: 04/15/2003 09:48 AM Balance: $0.00 Amount 118.76 Current Pmts 69.25 45.01 4.50 Total: 118.76 D03 -110 PENDING 04/15/2003 7725 04/16 9716 TOTAL 118.76 Printed: 04 -15 -2003 Prue t 0 ((0 S ( Type of Irpgct Ad drgs 3 �~ ( Date Called: Special Instructions: Date Wanted: ( ` -- Requeste f : t, Phone No: - 21) Le — 575 — c °() pproved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: (9/ z--)/74( Corrections required prior to approval. El $4REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: '".JA�i�.F/+�diCNI¢ ti1r+Y>4iyiYwSiO.�.4:e �,:.!iFs, • it Ciz of Tukwila Fire Department Thomas P. Keefe, Fire Chief Project Name ) ! r t v• c 4 , Address 3Yfo , i /11—( / 3) T.) / J . f S Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: _ A , _ Authorized Signature FINALAPP.FRM TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Rev. 2/19/98 Steven M. Mullet, Mayor Permit No. 0.:53"/ i 1- 0 Suite # /0- . � 1 -02 Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 ■ City of Tukwila Building Dept. Chris Baisch Apollo West, LLC Corporate Office 5315 E. Trent Spokane, WA 99212 (509) 534 -6972 Regional Office 13123 N.E. 124th Kirkland, WA 98034 (425) 820 -4141 9103 N. Division Ste. A Spokane, WA 99218 (509) 466 -5542 1421 N. State St. Bellingham, WA 98226 (360) 738 -1748 11g..1(, -(2Ac6 CcL.Q(2_ I'm writing this cover letter to explain what we're wanting to do at our warehouse at 1233 Andover Park East Tukwila, WA. We have been working with Dave Larson to modify the existing racks to comply with current code requiring that the highest storage shelf be less than 8' in height. Upon the recommendation of Mr. Larson, we plan to have a welder disable the racks to a max. height under 8' by welding metal pieces over accessable rack openings. Also all racks would be bolted to the floor per recommended installation instructions. Attatched will be a drawing of the overhead placement of the racks in our warehouse. 003 110 4434 W. Clearwater Kennewick, WA 99336 (509) 735 -3443 9165 Ridgetop Blvd. N.W. 3330 Pacific Ave. SE Silverdale, WA 98383 Suite 105 (360) 692 -3776 Olympia, WA 98501 (360) 413 -9808 6111 Tacoma Mall Blvd. Tacoma, WA 98409 (253) 471 -0321 RECEIVED OITY OF TUKWILA APR 1 5 2003 PERMIT CENTER 348 -D Bosanko (Hiway 95 & Bosanko) Coeur d'Alene, ID 83815 (208) 769-7300 12 SW Everett Mall Way 339 Tukwila Pkwy. Everett, WA 98204 Tukwila, WA 98188 (425) 710-9003 (206) 431-8583 October 7, 2003 Christian Balsch 1233 Andover Park East Tukwila, WA 98188 RE: Permit Application No. D03 -110 1233 Andover Park East Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to November 3, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania'Spencer Permit Technician Xc: Permit File No. D03 -110 Bob Benedicto, Building Official City of Tukwila Department of Community Development • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. Steven M. Mullet, Mayor Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206-431-3665 ``:‘ . ACTIVITY NUMBER: D03 -110 PROJECT NAME: APOLLO SPAS SITE ADDRESS: 1233 ANDOVER PARK EAST DATE: 04 -16 -03 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Keki Aw& 4 4 Building Division WI Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04 -17 -03 Complete 1E Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROWING: Please Route , E32( Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip,doc 2.28.02 KAMIT COORD COPY PLAN REVIEW /ROUTING SLIP (/ - 4 Fire Prevention Q Structural ❑ PERMIT COORD COPY Planning Division Permit Coordinator Not Applicable ❑ DUE DATE: 05 -13 -03 Not Approved (attach comments) ❑ DATE: taFS95iJM+ptSdf , WO 1pUt? rOA STATE OF WASHINGTON ) ss. AFFCONT 1/13/00 CITY OF Z .. KWILA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION COUNTY OF KING ) \k D )Jt • ga 1 C ( , states as follows: 1. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. , and will therefore not be performed by a registered contractor. engage an unregistered contractor to perform construc I understand that I may be waiving certain rights that I mi• • • he 'se have, rifer state law in any decision to APPLICANT c2 Signed and sworn to before me this s loN et 0 C O residing at day of H -4 017 . NOTARY PUBLIC in and for the State of Washington, Name as commissioned: SK--- ( ---e> My commission expires: Y-Adv-61 County. 18.27.090 Exemptions. This chapter shall not apply to: 1. An authorized representative of the United States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of a structure; 6. Any construction, alteration, improvement, or repair of personal property, except this chapter shall apply to all mobile /manufactured housing. A mobile /manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than $500, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division AFFCONT 1/13/00 • of the operation is made into contracts of amounts less than $500 for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner who contracts for a project with a registered contractor; 12. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but this exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 13. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 14. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his license; - 15. Any person who engages.ih the•activities herein regulated as an employee of a registered contractor with wages as his sole compensatiorn;- 16. Contractors on highway who have been prequalified as required by- chapter 13 of the Laws of 1961, RCW 47.28.070 with the department of transportation to perform highway construction, reconstruction, or maintenance work. ,Y, SCALE: /8' =1 -o PARTITION / ELEC. / DATA/ PHONE PLAN PARTITION NOTES CONTRACTOR TO VERIFY DIMENSIONS FOR ALL PLU 3IN6 PARTITIONS. PARTITION LEGEND 4 I' fz GE i N EXISTING PARTITION TO REMAIN. ELECTRICAL LEGEND WALL MOUNTED DUPLEX REGE3PT'CAL OUTLET WALL MOUNTED DUPLEX RECEPTACLE OUTLET - DE'IGATED 120V, 20A WALL MOUNTED QUADRAPLEX RELEY'TAGLE OUTLET WALL. MOUNTED TEL HHOPE OUTLET ItAU. MOUNTED DEDICATED TELEPHONE OUTLET WALL MOUNTED GOM 3INATION TEL-PHONE AND DATA OUTLET EXIS ^N6 RETROFIT EXISTING OUTLET GROUND FAULT INTERRUPTER NEW CONTRACTOR TO VERIFY ALL DIMENSIONS. ALL DI MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR PIREiCTiOVN. ALL PARTITIONS UNLESS O1}BRWISE NOTED, SHALL BE CONSTRUCTED WITH META. 511405 AT 24' O.G. WITH 56' TYPE 'X GYPSUM WALLBOARD EACH SIDE. THERE SHALT BE NO EXPOSED PIPE, CONDUIT, DUCTS, VENT'S, ETC. ALL SUCH LINES SHALL BE CONGEALED OR FURRED AND FINISHED, UNLESS OTHERWISE NOTED AS EXPOSED G016TRUGTION ON DRAWINGS. OFFSET STUDS, WHERE REQUIRED, 50 THAT FINISHED PART SURFACE WILL BE FLUSH, IPNLE56 OTHERWISE NOTED. PROVIDE FURRING AT EXISTING PARTITIONS AS REQUIRED TO INSTALL ELECTRICAL ITEMS AS INDICATED ON THE DRAWINGS. DOOR AND CASED OPENINGS NIiTHOUT LOCATION DIMENSIONS ARE TO BE SO( INCHES FROM FACE AT HINGE SIDE OF DOOR TO ADJACENT PARTITIONS. ALL EXIT DOORS SHALL BE °FINABLE FROM TINE INSIDE WITHOUT USE OF KE( OR ANY SPECIAL KNOWLEDGE OR EFFORT. PROVIDE SHAT METAL REiNFORGING ;8' HORIZONTALLY MOUNTtP SNIP OF 20 6A. GALVANIZED SHEET METAL) IN PARTITIONS FOR INSTALLATION OF WALL HUNG CABINET WORK AND PANELING WERE INDICATED ON DRAWINGS INCWDIN6 ALL Oft 43 PROVIDED !TBLS. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DESIGNER AND TENANT APPROVAL PRIOR TO MANUFACTURE OF ANY CABINET WORK, MILLWORK, MD ANY OTHER O4ICiAL ITBEi REQUIRING CUSTOM SHOP F.ABRIGATED WORK. ALL WAL. MOUNTED TE E'HHOPE AND ELECTRICAL OUTLETS TO BE INSTALLED 16' ABOVE FLOOR UNLESS OrISE NOTED. ALLANY (ORE DRILL LOCATIONS SHALL 5E VERIFIED WITH DESIGNER PRIOR TO DRILLING. AL L44/5ED GORE DRiLL5 SHALL BE PLUGGED AND GAPPED AS REflVIRED TO MAINTAIN FLOOR FIRE RATINE.. ALL TELEPHONE AND COMPUTER WIRES SHALL BE PALLED BY TENANTS CONTRACTOR UNLESS OTHERWISE NOTED ELECTRICAL CONTRACTOR SHALL PROVDE PULL WIRES AND 80X S AT EACH LOCATION. NOTOT_ CONTRACTOR TO REUSE AND / OR RELOCATE EXISTING ELECTRICAL / TELEPHONE OUTLETS WHER.E POSSIBLE ALL EXISTING ELECTRICAL / TELEPHONE OUTLETS NOT SHOYW ATE TO REMAIN USE E3UILDIN6 STANDARD ELECTRICAL FIXTURE' THROUGHOUT L 4±55 OTHERWISE NOTED 4 5/5 TENANT PARTITION - B/S METAL 511UD5 • 24'O.C. WITH 518' TYPE 'X' 6413 ON BOTH SIDES FROM FLOOR TO UNDE3251DE OF HUNG CEILING. PROVIDE SOUND ATTEW}�T10N BATT 'T qt"'") 1 SLIDING WINDOW SYSTEM - 4' -O'r4 X 3' -011 WItH SILL b +3' -0'AFF. rhue ELECTRICAL NOTES-VERIFY FINAL LOCATIONS W/ TENANT KEY NOTES ■ ALIGN FINISHED SXFACES. . GBrTfflUNE OF KLLIOWCOLUMN AND PARTITION B. NOT USED SCALE :1 /8"= i' -0° 4. PROVIDE B/5 STAINLESS STEM SiN .V4 IW,TA HOT VIATER DISPENSER, 411. P-LAM BACK-SPLASH COUNTERTOP, BASE AND UPPER CABINET WITH ONE ADJUSTABLE SHELF. PROVIDE GOLD WATER LINE FOR TENANT PROVIDED COFFEE MAKER, IF REWIRED 5. TENANT PROVIDED REFR1&BRATOR PROVIDE COLD WATER LINE, IF REQUIRED LIGHTING NOTES REFLECTED CEILING PLAN PROVIDE FIRE DAMPERS AT ALL SUPPLY AND RETURN AIR OUTLETS, INLETS, OR DUCTS PENETRATING FIRE RATED ASSBCLIES, BBY.LOS RES, WALLS, FLOORS, OR SNP AGES, AND AS REWIRED BY FIRE DE3'ARTNBNT, IF APPLICABLE. CONTRACTOR SHALL OBTAIN APPROVAL FROM DESIGNER OF ALL THERMOSTAT LOCATIONS. ALL REQUIRED EXIT SIGNS SHALL HAVE LETTERS SIX INCHES HIGH MINIMUM AND SHALL CONFORM WI'I+ ALL APPLICABLE CODES. CEILING HEIGHTS ARE FROM SLAB TO FINISHED CEILING. LIGHT SWITCHES SHALL BE INSTALLED AT +48' AFF. MULTIPLE SWITCHES SHOULD BE GANGED TOGETIE R UNLESS OTHERWISE SPECIFIED. CONTRACTOR SHALL PROVIDE E iENCY LIGHTING, STROBE LIGHTS, AUDIO - VISUAL ALARMS, TO MEET AL APPLICABLE CODS. CONTRACTOR TO VERIFY AU.. SWITCH LOCATIONS WITH TENANT PRIOR TO INSTALLATION HUNGER O` SWITCHES FOR OPEN AREA 15 BIDDER DESIGN. SWITOES INDICATED ON DRAWING FOR .OPEN AREA ARE FOR REFERENCE ONLt' CONTRACTOR SHALL PROVIDE SEISMIC BRACING 0 ALL. RELOCATED LIGHT FIXTURES. DOOR # RATED 300 302 303 304 305 WIDTH HEIGHT TYPE B/5 B/5 B/5 A A A A A THICK 13/4' 13/4' 13/4' 13/4' 13/4' B/5 SOLID CORE DOOR DOOR SCHEDULE MAT. FINISH HARDWARE FRAME HARDWARE MAT. FINISH SGWD SCWD SCWD SGWD B/5 B/5 5/5 B/5 B/5 DOOR TYPES E = EXISTING TO REMAIN NQ11:_ CONTRACTOR TO REUSE AND RELOCATE EXISTING DOORS AND HARDWARE MERE PQSSII3LE. B/5 B/5 B/5 B/5 B/5 B/5 B/5 B/5 LIGHTING LEGEND i ALL DOOR HARDWARE SHALL BE LEVER HANDLE STYLE MANUF. = BUILDING 5TANDARD ALL DOORS TO BE EGVIPPED WITH LEVER -TYPE LATCHING HARDWARE OR OTHER APPRO/ED HANDICAP ACCESSIBLE CONFIGURATION PER ABC SECTION 1106 ALL DOM. TO BE OPBNABLE FROM THE INSIDE WITHOUT A KEY OR ANY SPECIAL KMOY'1.' OR EFFORT EXISTING 5/5 2 x 4 FLORESCENT LIGHT FIXTURE TO REMAIN RELOCATED EXISTING B/5 2 x 4 FLUORESCENT LIGHT FIXTURE INDICATES 24 HAR FIXTURE 4 B/5 INCANDESCENT/FLUORESCENT DO WLIGNT EXISTING ILLUMINATED EXIT SIGN - DIRECTION OF ARROW *A B/5 SINGLE SWITCH (2) INDICATES QUANTITY EXISTING GWB E EXISTING TO REMAIN R RE ATE EXISTING FIXTURE N NEM SWITCH LIGHTING CALCULATIONS REMARKS HARDWARE TYPES-VERIFY W/ OWNER HYV -I - TENANT ENTRY B/5 EXTERIOR DOOR HARDWARE 4 CLOSER 1 - TENANT INTERIOR. LOCKING B/5 LOCKSET HW -3 - TENANT INTERIOR. LATCHING B/S LATCHSET PU5 1(o NOTE: CONTRACTOR TO REUSE AND / OR RELOCATE EXISTING LIGHT FIXTURES AND SNITCHES *ERE POSSIBLE. CONTRACTOR TO RESHITGH / RECIRCUIT U6HT SWITCHES AND LIGHT FIXTURES AS NEEDED. ALL EXISTING LIGHT FIXTURES / SWITCHES NOT SHOYW ARE TO REMAIN. ALL EXISTING LIGHT FIXTURES TO REMAIN WITHIN TENANT SPACE, NO PROPOSED CHANGE IN BERGY USAGE. NOTE QO NOT FASTEN TO ANY CURTAIN WALL SILL, HEAD. OR MULL I ON COhT 25 GA. GALV ST 1. PRUNER CHANNEL ANCHORED TO FLOOR W/ PO VER ACTIVATED FASTENING SYSTEM • 24 OC MIN. 25 6A. MIL. STUD TOP TRACK, BRACE TO STRUG'URE Hi EITHER •12 6A. SLAV. 5T1. SUSPENSION HANSEN WIRE SET OR 25 GA. MTL STUDS • 8' 0.G. OR 2 PER WALL SECTION MINIMUM, ANCHOR TO TOP -/ TRACK PER MFG REGUIREMENTS R• II INSULATION IF REQ roR ACOUSTICAL WALL N/ 4' WIDE R -2I BATTS CENTERED OVER VIAL L AND CEILING GRID \ NOTE: DO NOT - =.ASTEN TO ANY CURTAIN WALL SILL., HEAD OR MULLION '\ SECTION - WALL TO MULLION SCALE: N.T.S. F - 1 — PART.` ON AS PER PLAN -- SiLL EE LOW EAREAK METAL PAINT "O MATCH PART: TION . - FOAM TAPE 0 MULLION HEAD I SILL - - MULLION MULLION WiNDOYV SYSTEM EXTER OR &LAZING BREAK MTL PAINT TO , 9ATCH PARTITION E12(3"E OF SILL — TYP. PART TION WALL. REFER TO FLOOR. PLAN FOR ACTUAL WALL TYPE SECTION - WALL JOG TO MULLION ) SCALE: N.T.S. 25 GA. STUDS OR WIRE HANGED IONAL AGOJ5 T BAIT IF REQUIRED EXIST. CONT. 'L' MTL TRIM W/ PAPER WING 25 GA. &ALV 2 1/2 OR 3 I/2' (VSE 13/5) MTL. STUDS • 24' O.G. 5/8' TYPE . x: FIRE - RATED GYVE C 3 ) SECTION - BUILDING STANDARD PARTITION SCALE: N.T.S. NOTE. I. DETAIL RACES PROVIDED PER ICBO ER 4011 CO N E L L till. src`it.Clsr• DESIG 22000 - 64th Avenue W., Suite 2F Mountlaae Terrace, WA 98043 T: 425 -570 -6706 F: 425 -774 -8219 REGISTRATi0N w rc�315 o� ^ T ‘. A ' . b. rE� ►1.rz ST aTE O F MA&•if33Ta4 PROJE - NAME SHEET NO. AES LOGISTICS TENANT IMPROVEMENT BLDG. 1 SUITE 306 RIVERVIEW PLAZA 16040 CHRISTEMSEN RD. TUKWILA, WA. 98188 _ ;; DESIGN TEAM PROJECT NO.: 02.218 PRINCIPAL: CK DRAWN BY: ERL CHECKED BY: CK PROJECT CONSULTANTS ISSUED /REVISIONS 3.28.03 ISSUED FCR RECEIVED CITY C'a TUKWILA MAR 2 8 2003 PERMIT CENTER SHEET TITLE PARTITION / ELEC. / TELE DATA/ REFLECTED CEILING PLANS A-1L site plan revisions