Loading...
HomeMy WebLinkAboutPermit D03-139 - PAC SUN - TENANT IMPROVEMENTPAC SUN 17340 SOUTHCENTER PARKWAY D03 -139 ..., . • ;'iA�aei.ttw' City of T7ikwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049079 Permit Number: D03 -139 Address: 17340 SOUTHCENTER PY TUKW Issue Date: 06/09/2003 Suite No: Permit Expires On: 12/06/2003 Tenant: Name: PAC SUN Address: 17340 SOUTHCENTER PY, TUKWILA, WA Owner: Name: MBK NORTHWEST DEPT 436 Address: P 0 BOX 34935, SEATTLE WA Contact Person: Name: MATT HARDESTY Address: 2102 BUSINESS CTR DR, #130, IRVINE, CA Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Water Meter: doc: Devperm DEVELOPMENT PERMIT Contractor: Name: HARDESTY & ASSOCIATES INC Address: 1991 VILLAGE PARY WAY 180, ENCINITAS, CA Contractor License No: HARDEAI066PP D03 -139 Phone: Phone: 949 - 253 -4188 Phone: 760 - 944 -0499 Expiration Date: 11/02/2003 DESCRIPTION OF WORK: NONSTRUCTURAL DEMO; NEW NONBEARING PARTITIONS AND CEILINGS, PLUMBING AND LIGHT FIXTURES, HVAC AND INTERIOR FINISHES Value of Construction: $ $85,000.00 Fees Collected: $1,470.94 Type of Fire Protection: SPRINKLERS Uniform Building Code Edition: 1997 Type of Construction: IIIN Occupancy per UBC: 0023 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Profit: N Non - Profit: N Water Main Extension: N Private: N Public: N N Printed: 06 -09 -2003 doc: Devperm City of Thkwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: D03 -139 Date: o' wpi / 3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constr ction or the perfor an a of work. I am a orized to sign and obtain this development permit. 40 Signature:�G`��i Date: 41 Print Name: Q_X 92_ ‘6z42J4fq.LcrAl This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 06 -09 -2003 YM#eru{ Anv t `YYN'M'NYk City of Takwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS z Parcel No.: 2623049079 Permit Number: D03 -139 = i� Address: 17340 SOUTHCENTER PY TUKW Status: ISSUED S ce uite No: Applied Date: 05/09/2003 ¢¢ D Tenant: PAC SUN Issue Date: 06/09/2003 U U O N U) ILI -11- WO 2 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be u_ Q inspected by that agency, including all gas piping (296- 4722). 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. = a I— III 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical z H work will be inspected by that agency (206- 835 - 1111). Z O W W U N 6: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any 0 E- construction. These documents are to be maintained and available until final inspection approval is granted. W W U 7: Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 8: Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. U Y2 O ~ 9: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear Z identification showing the fire performance rating thereof. 5: All mechanical work shall be under separate permit issued by the City of Tukwila. 10: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 11: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 12: There shall be no occupancy of the building(s) until the final inspection has been completed by the Tukwila Building Inspector. 13: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform Building Code and the Washington State Ventilation and Indoor Quality Code, Chapter 51 -13 WAC. 14: ** *FIRE DEPARTMENT CONDITIONS * ** 15: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 16: ** *FIRE EXTINGUISHERS * ** - UFC Article 10 and NFPA 10. 17: Maintain fire extinguisher coverage throughout. doc: Conditions 003 -139 Printed: 06 -09 -2003 a o Q keisi datg.' k. City of Takwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 18: The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) 19: Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. 20: Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 106.3) (UFC Standard 10 -1) 21: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 22: * ** EXITS * ** - UFC Article 12 23: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) 24: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) 25: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) 26: * ** SPRINKLER SYSTEMS * ** - UFC ARTICLE 10 -NFPA 13 27: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. 28: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13- 4- 5.5.3.1) 29: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 30: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 31: Local U.L. central station supervision is required. (City Ordinance #1901) 32: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1646 - NFPA 72 33: An approved manual fire alarm system is required for this project. The fire alarm system shall meet the requirements of the Americans With Disabilities' Act, chapter 51 -20 WAC (Chapter 31 Accessibility), N.F.P.A. 72 and the City of Tukwila Ordinance #1900. doc: Conditions D03 -139 Printed: 06 -09 -2003 a. '; City of Takwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 34: Maintain fire alarm system audible /visual notification. Addition /relocation of walls or partitions may require relocation and /or addition of audible /visual notification devices. 35: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 36: Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1900) 37: Local U.L. central station supervision is required. (City Ordinance #1900) 38: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 39: * ** BUILDING CONSTRUCTION * ** - (UFC, UBC) 40: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) 41: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of the Uniform Building Code. (UBC 804.1) 42: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 43: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 44: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Print Name: /N.\S 5A/ doc: Conditions D03 -139 Date: a�:fh Printed: 06 -09 -2003 APR 1.3 '03 01: 25P11 TUKWILA DCD /PW CITY OF TUKWILL , Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd,, Suite 100 Tukwila, WA 98188 Site Address: 0 - G('rrfe( P f (A - Tenant Nanie :_PaG So Property Owners Name: VI I c a Pea Mailing Address: S 2-3g 1 1 +a l ve . � t Ackeyvi r!^a+.ei c__A cis* Co US' Name: 1''Ar.d l Mailing Address: i c 2 1 t / " ; G t r . 1)'- _14-130 f (' ✓ f1. z , c h Company Name: j t ev " S SOZ r +eS Mailing Address: S 6 city ,., Statc Zip Contact Person: f � a r d e r s - ' _ Day Telephone: 4 / ? -25 S' - 4 /157 E -Mail Address: SOM/La oho oho-v Fax Number: ( -7 4 N — 25;3 — / $`j Contractor Registration Number: t1A RtEA 066) pp Expiration Date: **An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance** Company Name: AAP Mailing Address N , r P_ i Contact Person: � r' A' 1 y S ri i E -Mail Address: f t g T r 1 � • 4 ... `C 4 3a;t.•�'i;1, i i , f � Company Name: /0 f• E i 0 2rt -� Mailing Address: . 5 SD 1 N ) +/-■ 1 V Contact Person: t/ t si Barn E -Mail Address: 13ppliaaiions1permlt spplicll:on (3.2003) 112003 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Page 1 City / • P.2 /5 King Co Assessor's Tax No. :_p2C -ti 767 9 'lix AZ. ¶ ;O(; Yr. Suite Number: I/ 314 0 Floor: I New Tenant: Jg ,.,, Yes ❑ ..No State Zip Day Telephone: 94`i- 2S 3-4 f g City State Zip aS.56 et a�G -S. C 4 Fax Number; qLe- 23 - q 49 a - •I t City State Zip Day Telephone: 1 -'9' 6' I } Fax Number: 4 go -- City State Zip Day Telephone: U Z Fax Number: ' 1r:r ��'•IH • 'y i l : ' . ? •n ryd �'•'�'.• •1• J,'�ii' ,>.. 'ry:. v ri ,A •:• - �4. •1! .,r rV iw�� ,�� • r J •r `�# � 4 ' 'rt•. u�r7 .r'S �� , re^ 'I' .5:% f ir I• :' '.l � 'Fir ;,�• .,; 4... • , n , • ; i , . I'J nV ,! � •Sr • '' . '. • 'S:. �,' _ .J' h 1 1: . ' _ �Ij� : � ? �ali'�i i' .i �'.; V �; l''',41,'''....",,. .t r • ,I,,�� ,L . �1t , r .;1 ';i��q�1'[aC�� I .r,. ... �;f: = ' •i QTY S �.� ^t %� : .4 / ~, .L I h' '�$k�9i7�1$�1 , , �.. :1- " :r " " ^ , '..+ r. . �t�'�l ':r� r. � � .... 4 ,•IM :,1 ": ti t s : I ::�� .' rr (r ^ •, et , ' .1 i 1 11 - .i� �:y: ii �:r 1 .,n•:. sic J'. ;�IS: ' �" '.;;: �i : X .ry h''. _ rV n 81�}r.� � .:7 ' 'I.� �C�i�1 ��;,;V:. : . + i'...,.. 2SY� „ :h � ; rr �tr: b l ,ii l ,. , � . �� .... ...�,� -: {'::U •r �G�kf ' •fir, :•.I r s ^,'. J. aY, !!': . r ,r,.. ,�} ?r4 • 'i ,7J ��J. u. I.. • :Iii ., ,� „r •,., . r• ••. : in.,.r,' wi � , ! •. J. .r ��. j�h; r. 4 .. G Q 3 3 l i iµ+.` • ' . 1._ ..-----. :1•d ' . � ' ; I _) • 3' ' F .. • •• A F/q §M4,i,t1 L � r T,i • r r3che6r =C atgga, : : • • i J , 17610001:C i a ra • : OV,C:1 rl D d r 1 ; • ;; +;, r ” ' M. r J . i . r . PR j 03•. :27PM TUKWILA DCD /PW Valuation of Project (contractor's bid price); $ 5 0O Scope of Wprk (please provide detailed information): rare {+t 071 d` - r 1 .'1 'j h. q1 b /✓► Will there be new rack storage? X.. Yes 0 ,. No If "yes ", see Handout No, for requirements. Existing Building Valuation: $ L: PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inohcs and overhangs greater than 18 inches) *'For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ,...Yes $..No If "yes ", explain: FIRE P • OTECTION/HAZARDOUS MATERIALS: ►:� .. Sprinklers ❑ ..Automatic Fire Alarm ..None 0. Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? [] ,. Yes No ,(f "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material S ty Data Sheets. 1spplicat3ons\penait applica ion (1.2401) 1(2401 Page 2, Site Address: Tenant Name: Property Owners Name: Mailing Address: Name: E -Mail Address: Contact Person: E -Mail Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: 1applicationilpennit application (1.2003) 1/2003 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** (SI.TE LOCA:TI Mailing Address: City Fax Number: Company Name: Mailing Address: .ENGINEER OF, RECORD '' - , All plans must be wet stamped by Engineer of Record Page 1 King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: D .... Yes [] ..No City �',� -,,,, .terns.: ;;.w. .m�.,�i..,•., ^�•rrll,��i�� %?,. •Y.. -„ Day Telephone: City Day Telephone: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Company Name: Mailing Address: City Day Telephone: Fax Number: City State Zip Day Telephone: Fax Number: State State State State Zip Zip Zip Zip r ^`�`I .�?: . � � ��' irJt+ -i r PilBLid- FVO,�2KS;PFRIV[tTriNFr riirs' nN �:�n� =e z =ni �� , W �,,104i. Scope of Work (please provide detailed information): Street Use: ❑ .. Street Use Land Altering and /or Hauling: ❑ .. Land Altering: ❑...Cut Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: lapplicationlpermit application (1.2003) 1 /203 Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑... Channelization/Striping Storm Drainage: ❑ .. Storm Drainage ❑...Flood Control Zone Sewer Information: ❑ .. City of Tukwila Sewer District ❑ .. Val Vue Sewer District ❑...City of Renton Sewer District ❑ ..City of Seattle Sewer District 0.. Sanitary Side Sewer ❑ .. Sewer Main Extension 0 ..Private ❑ .. Public Water Information: ❑ .. City of Tukwila Water District ❑ .. Water District #125 0... Highline Water District ❑...City of Renton Water District ❑ .. Water Main Extension ❑ .. Private ❑...Public ❑ .. Water Meter/Exempt: Size(s): ❑ .. Deduct 0... Water Only ❑ .. Water Meter Permanent #: Size(s): ❑ .. Water Meter Temporary #: Size(s): ❑ .. Est. Quantity: gallons ❑ .. Fire Loop/Hydrant (main to vault) #: Size(s): ❑ .. Landscaping Irrigation ❑ .. Miscellaneous: Water ... ❑ Call before you Dig: 1- 800 - 424 -5555 ❑...Curb cut/Access/Sidewalk cubic yards 0... Fill cubic yards ❑ .. Hauling City Sewer ... 0 Sewage Treatment ❑ Page 3 Day Telephone: Day Telephone: City State Fire Line .... ❑ Zip State Zip 4 /if . iR" wnt " aA '' J% i� ,0. � lak�y ,.� ..r r?1 ...S....,`t.c...�b lY ^� � 1 v;Plb.xk � �N'�tYt^`.f � l+% ce �k, Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Will there be new rack storage? ❑...Yes 0 .. No tapplications\pcnnit application (1.2003) Il2003 If "yes ", see Handout No. Existing Building Valuation: $ for requirements. Provide 'All . Building Areas in Square Footage. Below • •1" Floor.:: .2"0 Floor 3fa Floor Floors , thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Existing Interior Remodel.. Addition to Existing Structure New Type of Construction per UBC Type of Occupancy per UBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑...Yes 0 .. No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ .. Sprinklers [...Automatic Fire Alarm ❑...None 0.. Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 .. Yes ❑...No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. UTILITY DISTRICTS: Note: If the utility district is not City of Tukwila, you must provide written verification and approval from that utility district at the time of permit application. Water .. City of Tukwila Water District ❑.. Water District 1'1125 0... Highline Water District ❑...City of Renton Water District Sewer 0.. City of Tukwila Sewer District 0.. Val Vue Sewer District 0...City of Renton Sewer District ❑...City of Seattle Sewer District ❑ .. Septic System (If property is served by a septic system, 2 copies of approved septic design from King County Health Department must be submitted at the time of permit application) Pagc 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU • Furnace >100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm/Ind MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Day Telephone: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): S Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ....❑ Replacement ....0 Fuel Type: Electric p Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: PERMITAPPLICATION •NOTES Applicable t6 all in th><g applicatiati .. Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO IZED AGENT: Signature: 1 . Print Name: 'A'- "/ s r - • Day Telephone: 7cO' �9X V 3 �. Mailing Address: �8 / �i9 /fie 7179 472 & "V 9 / i 2 007'2. C/9 / LC)61-2 State Zip tapplicationatpermit application (1 -200)) In003 Page 4 City Date Application Accepted: - ? -D3 Date Application Expires: //-9 Staff Ini /`—U i Fax Number: Date: Zip . "ti.!?t,'�'d: $i; ; ?.; C�i:;'��rrr•,:.; +. . ...�S.rm,Hfri!a,.rt'rm:v,.Y'« TRANSACTION LIST: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 z RECEIPT . 1 Z �w Parcel No.: 2623049079 Permit Number: D03 -139 6 v Address: 17340 SOUTHCENTER PY TUKW Status: PENDING v 0 Suite No: Applied Date: 05/09/2003 u) w Applicant: PAC SUN Issue Date: - H u) u. w 0 Receipt No.: R03 -00576 Payment Amount: 577.69 u. Q U, a Initials: SKS Payment Date: 05/09/2003 01:38 PM = w User ID: 1165 Balance: $893.25 F- _ zI— I— 0 z i` ILI • w Payee: HARDESTY & ASSOCIATES INC 0 O N D i` 111 u 2 Type Method Description Amount F- �' O 1 Payment Check 28070 577.69 W z U- - I O 1- PLAN CHECK - NONRES Account Code Current Pmts 000/345.830 577.69 Total: 577.69 0526 05/12 9710 TOTAL- 577.69 Printed: 05 -09 -2003 4aisaV''ktia. z TRANSACTION LIST: doc: Receipt City of T 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT z • ,,_ Z re W Parcel No.: 2623049079 Permit Number: D03 -139 m Address: 17340 SOUTHCENTER PY TUKW Status: APPROVED o O Suite No: Applied Date: 05/09/2003 co a Applicant: PAC SUN Issue Date: Et) I CO u,. W 0 Receipt No.: R03 -00715 Payment Amount: 893.25 2 Initials: BLH Payment Date: 06/09/2003 09:18 AM 0 j . User ID: ADMIN Balance: $0.00 I C! = W H Z . Z1... Payee: HARDESTY AND ASSOCIATES INC Z O W • W U O — Type Method Description Amount CI I- W W Payment Check 28458 893.25 H r- - ~ O .• Z W U= 17- l- ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 888.75 4.50 Total: 893.25 9 06 /10 1716 TO'T'AL 893.25 Printed: 06 -09 -2003 ,i.i1ri #4.1.4vas. s Project: Ge Type of Inspection: .) Address: ,7 tO ,SG. Date Called: Special Instructions: / ate Wanted^ a . 7 2- . 9'0-3 e' Requester. Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector �(?-'A1 11 �✓ 2— n $47.00 REINSPECTION PE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit «t . Date: (206)431 -3670 r.ba y'. Pro a c C Type of Inspection: - I �`-- Ad ,to Date Calle ' Special Instructions: c ) 04 i--' Date Wanted/ ,--a'. Requester; r el-- Pho e No: r Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERM CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: /) /94-47 le2 e)‹. ). z,e4,e 7 47 *7-1, /i, f-k S Inspector: 7ft D 77 - 7 - 03 Corrections required prior to approval. El $47.00 REINSPECTIOPF REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: 1 - 5? ..x , \ / Is t lev . ‘ - I _ _c r . Li' 0 )1 , roq_.1.1..s. -4\\0. ta V\ e, vN ..e. e A y\ ctoPc 1/10 c w■Ae X 6-C-\ \ov Coif\ a b.) AV"\C\M■TAI-P (94 - -4 v i C_ • ) 1_, oa A izrA \■ 04 1/4.st eLcs. -car a 3- 1 14 k, A ce 1-ps(A,Ls. _ ■ V) 0 A rt A \I s i oinS , ,, 3.) Akr\c-ko Id 'at pr , r)airc. 3 O A f)c) ro vO S- ^Cc ■./, s 7 etivIparc‘r-1 (,)cc o--C S-1-ole i i 1 tot ,ivN ■ i B- 2.0 - o 3 ' prteti: k Type of Inspection: Add L f 0 s , 1 6,,, L , ritc.4 Date Calle :.... 30 ' , 3 ip SpJcial Instructions: 1 Pate Wanted 1 D....3 . . .m Requester: ImN iN INSPECTION NO. - 7 - Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 ■ 1:1$47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (206)431-3670 Corrections required prior to approval. Inspector R ceAt Date 3 ) 0 3 Receipt No.: Date: ' COMMENTS: .) -t' f - A C �t l r' c t 4' l t via ()l ' )t,1 I nor() 2—) . 11-() V) \ A4 rr til S In-" ..k.1 1 .L.„,-- r(-)\ v, trrc s\ -( tfr, 3) kVt. t.rr - c, YVAt Of rY) Flo( i r )1) Ak \LA C C. Un n 1c 2 5L A A' i () r4J y` a m` m. Requester: () k- ,), 1! ..Sc.( \-e 4 -A 1 1. V` .c.,--t-or Project:� � � V v� Type of Inspection: � . l ✓ ct Address: \ T 2»0 s.c. -t,w Date Called: - 7 -a--o3 ---, Special Instructions: ! Date Wanted: '' _) -) -02, a m` m. Requester: Phone No: .,.. ..r5.... -ir h�"y.= ... �� ,. � :.5.7.»" . 4 , •• . �,..r..;:.ry. trf..^r .r.x+ ..A�- •.�, -¢• .- _'r - 7 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila,:WA 98188 (206)431 -3670 Approved per applicable codes. w orrections required prior to approval. Inspector: � 4 uktv l ir Date: 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: Type of Inspection: 0 FrG IM i tckc — / p p r�r V < 1rl Spe ial /;, /!„Q lVJ"� Ins ions: ..► (,( it AO ( ,,, „Si L ���'vvvv DatiWanted: 7.7)1o3 2 l iv,-.\- i' WoM ,c ) A it _ , i U U° i P h o a N / o � : � � _.- �N 1ti t � � S () 5 e-e tA c -P A Op 1\ l (/ -- Gt /7 v o V. //i r )LP 41,d "' \ro4 a av4 P/C Pii< Pr Ject: Type of Inspection: Address: t ` 7 ii 0 _�< < etc �, Date Called: _ 77 . � o. -, Spe ial /;, /!„Q lVJ"� Ins ions: ..► (,( it AO ( ,,, „Si L ���'vvvv DatiWanted: 7.7)1o3 aA Requesters t P h o a N / o � : � � _.- �N 1ti t � � nspector: , INSPECTION RECORD, Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PER ( 06)431 -3670 Approved per applicable codes. El Corrections required prior to approval. Date: Ej $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: t COMMENTS. 7c &ftfV‘Arr\, C 2, k(hr ) . PI-P(1 vti ( A t OD (OVA I l A dres D S ,C ate C alled: & p U ir c fl f ft) t/R' ?, t � SP t S rN iC 1x)■ \4�v� Co -- Pi owl 1 �A�. _ a 1 �S G v 1 - >c 1 rvy.+ L'eSee � Ita m' 4() n p r t ,r t 1,-‘ 1,-‘ f n r7V' ► (toy G 1^ G Pon No: 5 3 14 .) A--4; v-sv.. \10%r1 '`")tG( f •) , 'f't ttf( iM154 �y\SI)lugt f14` I.00 T \ vim fir �' 0 t. .t:› Pr t: TO C S v...-in Type of Inspection: r 17� . 1/ 7� 1 I bQ.�(Ce�. A dres D S ,C ate C alled: Sp cia Instructions: D t Wanted: Ita m' Reques 21 r Pon No: 5 3 tea - s.c 1 err - rte,..- ....,�.+- r- ... - -- ,•..,�...._...�. _ .. .. . - .. - INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Date: PERMI Corrections required prior to approval. Date: El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: PrqfEjlt: A St/L/1 Tyke f Inipection: i i tv . fri....._. 1 I ,6 ATitif N)ate Dare Called: 1 - DI 03 Special Instructions: Wanted: ..... / 1 0..3 a.m. Request Pt,e 6: L INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMI CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: rOOM S--}oc\e vonm AcA\Uo% Inspector. - Date: 0 n $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be " --1 paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: *4 ' "• ;. •4 • I COMMENTS: Tni 1-ei room i-oa 1 Is &tut 1 4 If 00 IM LA- S I L ( 1 001 v1 (4 I \ l`. = c 1 -et.k kc4 I Iwo. ( �)c (I_ c bVGCli c -+ sus t oevk(Lod ( -pi \ I h ) vX ( . 1 0 ,0 G - 4 - 101^ Phone No: Project) ��� Type Type of�rl�pe� n -; � ,./.6.1 Address: 17� b s.C. Pt Date Called: ' 7 �� Special Instructions: Date Wanted: N ) Request (71 Phone No: : INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT (2 1 6)431 -3670 Approved per applicable codes. ID Corrections required prior to approval. Inspector: e" ) Date: 7 2 o3 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: Type of Inspection: Adtlress: 7, n SG � Date Cal ed: c'D f 43 Special Instructions: Date Wanted: / -2 7)63 a. m Requester: el Phone ne . 3- &-r- INSP NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 NO. (2 1 6)431 -3670 K A,)proved per applicable codes. Corrections required prior to approval. COMMENTS: .30 (i,,41/13 1 /2/41.324-21)L isowt-h, , 14,,o n $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ., - a�- t hs_ ;., ` u�lN�. '7 :;M4•�M A "' Mwsi "'� ' 'r�+1W.11r+,7r. r `" ,; i 1a.. '.w: >.:.;;5.:; >.?' w....rr COMMENTS: PMe / ff 'C C , // 0 - .,.. �- r Type of Ins ection: / l lc KY) I/9 i/ .--7 --t e ' -e- -- * / "( 14 .14 ,1 / Le- r l / 1 , , le , r ' fr2- L # 4 ,-7 ; z ) sk>,..e ,A2,..., 4,// .„,„„./._.; S . ( 9 % „' ,,,,/ 4 Pi/,/ )..1,„ t t . 1 e t / / . e ' t' - z ,..„/ � / - - - 7 . < , 2- '- - , 7S# 14.,-" 3 ') , 7 z- ,,, ._,,,,,...,. S t1 /4. > .c / �i /,•,mi l - .G2'/7*9 ----' -- 1 1 �� 4 ..4 / - (,d2,/,, 1, >1; Projec . n C : Sic i ') Type of Ins ection: / l lc KY) I/9 Address: / 7 3* S( � j Date Called: Cr / /o Special Instructions: a 2-41 Date Wanted: ( pp C3 .m. Requester: C is - P7 Phone No 2 5 3 -L /VR — 9( INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)4 1 -3670 Approved per applicable. codes. Corrections required prior to approval. Inspector: Date: v'' $47.00 REINSPECTION E E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: FROM : HARDESTY ASSOCIATES . B ate PermIt No. MATERIAL HANDLING ENGINEERrru; TEL (909) 869 -0989 • FAX: (909) e69 -o93 161 ATLANTIC AVENUE • POMONA • CA, 9 DSC I T N COVER SHEE.T TABLE OF CONTENTS SCOPE PARAMET> R$ SEISMIC DISTRIBUTION COLUMN ANALYSIS BEAM CONNECTION $HcLf ANALYSIS ANTI-799 DEVICE CHECK OVERTURNING ANALYSIS SLAB AND SOIL FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. •t Ar.?t c ENr I ,z • • FAX NO. : 760944 0399 Jun. 23 2003 04:21PM P2 P1 OJECT C SUNWEAR FOR SHELF MASTtR `- ---".� snEr NO. 2 of '10 ._..�. CALCULATED BY MYRON DATE 06-21-1999 REVISION N0, I ACC, 1 2 3 RA 4- n Yo 1 6 d ar 7 ° �J 8 9 1O C,4TY OF TAW AMMO JUL a 3 2003 iks NOTE CITY OF T I UK D j, JUN 2 5 2003 PERMIT CEr 1710; • . FROM : HARDESTY ASSOCIATES r1 rr�c. MATERIAL HANDUrIG ENGINEERING TEL (909) 869.0969 • FAX: (949) 869.0381 161 ATLANTIC AVENUE - POMONA • CA 91788 UiG 13 QUI�TY SHELVING ANALYS {S THE PURPOSE OF THIS ANALYSIS !3 TO SHOW 114AT THE FOL.LgWING LIGHT DUTY STORAGE RACK COMPLIES WITH THE REQUIREMENTS SET FORTH IN THE 1 997 UBC, UTILIZING CHAPTER 22, DIV X. PARAMETERS STEEL- 36,000 PSI ANCHORS- 1 /4 IN DZAM, x 2 IN. .MIN EMBED HILT! Irrrl (I.C.$.0, ##4627) BOLTS A307 SLAB- 4 x Z000 PSI SOIL- 1, P$F ZONE- 4 WITH A NEAR FAULT FACTOR OF 1 38' & 1 364 S 4a' I 24" 24^ � I II 2e l r • LIVE LOAD PER LEVEL a 1 20 LB FAX NO. : 7609440399 pROI1irCT PACT FI C SUNWEAR FOR SHELF MASTER SHEET NO. _ 3 _ ._ OF CALCULATED BY M QN _. DATE 06- 21' 999 Front %..e CM Of TUrtitU JUL 0 8 2003 Is Hoe EU Jun, 23 2003 04:22PM P3 2 24" 24" 24" Nslrai SI '1 ew RECEIVED CITY OF TUKWILA JUN •2 5 2003 10 PERMIT CENTER AIM FROM : HARDESTY ASSOCIATES • a INC, MATERIAL HANDLING ENGINEERING TEL: (909) 869.0969 FAX: (909) B69 -0981 161 ATLANTIC AVENUE • POMONA • CA 91768 SEISMIC DISTRIBUTION ANALYZE PER CHAPTER 22, DIV X OF THE 1997 ;Wt. THE STORY FORCE DISTRIBUTION lS THE SAME IN BOTH THE LONGITUDINAL AND TRANSVERSE DIRECTIONS. FRAME HEIGHTEN -' 96.0 IN DIST BETWEEN SHELVES =hrt 46.5 IN BEAM LENGTH•W* 48.0 IN FRAME DEPTH7d_. IN 0 OF LEVELS 3 V= 2.5*Ca*I *(WDL +WLL) /(1.4"R) Note: 1.4 IS THE WORKING STRESS REDUCTION FACTOR Na. 1 lc 1 Gas 0.44 < =__ Ca *Na b 'ZONE 4 R= 5.6 .cm== MOMENT FRAME DL• 42 LB /LVL LI= ZOO LS /LVL # OF LVLSo 3 SIjf AR DIAL( aL N Vtransva 2.5 . 0.44 * 0.44 * 1 * (41,67 LB 4. 200 LB Y•3 LVLS /(1.4 *5.6) = 102 LB SEISMIC SHEAR PER FRAME Vcof-V /2= 51 LB Mcol(1), Vcol *h1/2, _ (51 LB /2) * 3 IN /2 r 77 IN -L8 FAX NO. : 7609440399 Ti 35,163 INLB McoI(3),: (Vcol•Fi)T3 /2 = (51 LB -1.05 LB - 16.82 LB) A 4 6.3 ?�t 2 770 IN -LB Mconn(1)72 McoI(1) +Mcol(2) • • 1,200 IN-LB ;:l. .t.a.:::.1. r' , "J'';�it•:ix' .tiS.rks,;;, :k .iAr1�Y . 1 1'u A+ Jun. 23 2003 04 : 22FM P4 PROJECT_ PACI H C SUNWEAR FOR SHELF MASTER SHEET NO. . 4 OF 10 MYR CALCU ATE08Y_ ON DATE 06- 21 -1999 (SEC 2237.52) < = =NOTE: SINCE THERE ARE ONLY (3) MOMENT RESISTING BEAMS, THE LOADS OF THE NONE MOMENT RESISTING BEAMS ARE TRANSFERRED TO THE CLOSEST MOMENT • RESISTING BEAM LEVEL wx(DL +LL) hx wxhz Fl Fi*hx*1.1 5 1 242 LB /LVL 3 IN 725 2 L8 7.31N LB 2 242 t.61LVL ' 48 IN 11 600 34 LB 1857.5 IN LB 3 242 LB /LVL 95 IN 22837.5 6. LS 7199.4 IN L5 Mconn(2)c MCO1(2) +Mcol(3) • . •• 1,894 IN-LB : .. ere Can OF TU,i(0 ' '• nORD JUL 0 8 2003 Al N E--102 LB 9,064 INLB = Movt MC' t(2 )= (VcaI- FI) *h2 /2 = (51 LB -1 LB) 451,N / = 1,124 IN -LS RECEIVED CITY OF TUKWII.A JUN 2 52003 PERMIT CENTER .Vm FROM : HARDESTY ASSOCIATES r nrf MATERIAL HANDLING ENGINEERING TEL (909) 869.0989 • FAX: (909)869-C961 161 ATLANTIC AVENUE • POMONA • CA 917128 LAB AND SOIL SCOPF THE SLAB WILL BE CHECKED FOR PUNCTURE STRESS. IF NO PUNCTURE OCCURS, IT WILL BE ASSUMED T4 DISTRIBUTE THE LOAD OVER A LARGER AREA OF SOIL AND Witt. ACT AS A FOOTING. A.).FUNCTiURE • B),SLAB TENSION PCai(static)_ 725 # FAX NO : 7609440399 Pmax— 1.41Pcot +1.7'(P!ovt /depth) 2,299 # Fpunct= 2 *sgrt(f c) 89.4 PSI Apunc"= j(B +t /2) +(D +t /2)J *2tr . = 94.0 INA2 fv /Fv= Prnax/(Aounct *;:Aunct) •� • 0 -09 x.1,33 OK Asoil= (Pmax''144) /(foil) = 331.07 INA2 I. sgrt(Asoit) + t = 22.20 I a= sgrt(8'D)Yt . '.62 " b - � (L -B) /2 • 7.3 "# Mcont = w1p`•2/Z (1,33*fsoPbAZ). (144.2) ._ 245 "+ 5canc -+ 1 - tA2 /5 3 2.S7 IN""3 Fconc 5 - 145.34 PSI PROJECT PACIFIC SUNWEAR FOR f.LF MASTER — SHEi:"T NO. j O OF Q _ -- CALCULATED BY MYRQh� DATE 06-21-1999 • Movt= 9,064 "# Jun. 23 2003 04:26PM P10 OK 5.25 dentli : 12.0 " CONRE rE • Pc= 2,000 PSI. : t= 4.0 07. 0.65 C OIL frail= 1,000 'SF fb /Fbz tv'conci(Sconc *Fconc) ▪ 0.63 < 1.33 OK SLAB AND SOIL OK +" w Ir2 0 00 N0 J4 N LL w u_? =w Z I U� O N O I-- w w I H 92 0 • Z U= O ~ z r Yj.F+r•� iu:4. �p �a Y w�iJa }i4U�.�a• }bS!� -� : . FROM : HARDESTY ASSOCIATES MATERIAL HANDLING ENGIN6EPJR1G TEL' (909) 869.0989 • FAX: (909) 8894196 161 ATLANTIC AVENUE • POMONA • CA 417- -8 FAX NO. : 7609440399 COLUMN ANALYSIS ANALYZED PER 1997 UBC. SECTION PROPERTIES BASED ON THE. EFFECTIVE 'SECTION. Pstaticm OF LEVEL,'`''(WDL + WLL ) * (120LB + 25 L8) . 725 LB ' Pseismtc= E (FI*hn) /d'epth =(Mont /FRAM€ CEPT'ri) = 7882 1N -LB /12 IN) . = 657 LB • • � Ptotal= 1,382 LB � Mmax= 1,1141N -LB : I KxL cJrX x 1.2' 12 1N /0.506 1N 19.2 • . KyLy /ry = 1.2'1 Z IN/0.639.1N 22.5 . • <=•=, (iK Fe= nAaE/(KL/r)maxA2 = 573.3KSi' • Fy /2= 18.0 KSI SINCE, Fe , Py /2 THEN, Fn- Fy(1•Fyi4Fe) ' • . • • (EQ. C4.3) = 36 KS1'11 - KSt/(4 KSI)) 35.4 KSI Pm. Aeff'Fn (EQ C4 -2) = 21,26S LB �c= 1.92 A L Par' Pr/lc (EQ C4 -1) = 21268 LB/1.92 - 11,077 LS PJPa= 0.12 0.15 FLEXPRg CHECK: P /Pa + Mx /Max 5 1.33 (EQ C3.3) Amy THUS, Pno= Ae'`Fy - 0.6 I11�2 +36000 PSt = 21.607 LB CAP( OF EN K.A Pao= Pno /lc APPROVED RECEIVED = 21 607 13/1 .92 c.rrr of TIJKwo t 1 1,254 LB . JUL 0 8 2003 Ivtyield -My= Sx *Fy • • JUN 2 5 2003 - 0.208 IN ■3 * 36000 PS1 AS WAD . 7,474 IN -LB PERMIT CENTEI: Max= My /Of 7474 IN- L9/1.67 4,475 IN -LB Pcr= It "2EI /(KL)max "2 = nn2 *29500000.PSI/(1 IN) ^2 474,725 L8 : . Jun, 23 2003 04:23P11 P5 PEC PACIFIC SUNWEAR FOR SHELF MASTER SHEET NO. OF CALCULATED BY MY DATE , 06-21- 1999 dAETEN TO IJPPIC,.1 %N't1UW It: g* I' s:.aEW A' rf 1,67 Grnx= 1.0 Cb= 1.0 (EQ C4.1 - 1) FIRM . ina ` r?oktf w =w SECTION PR PERTIF A= 3.0 IN 6== 1.5 IN t = 0.07S IN Aeff = 0.600 mina Ix - 0.338 INA4 S:; = 0.208 INA3 rx = 0.751 IN Iy - 0.241 INn4 Sy = 0 1d3 INA3 r = 0.639 IN Kx =1.2 Lx = 12.0 IN Ky 1,2 Ly 12.0 IN Fy- 36 KSI E= 29,500 KSI Nx= {1 /(1 " -1 11/[1 "(1.92*1382 LB'474725 LB)) }"-1 0.99 .. (138Z L8/11077 LB) ± (11.44 IN- LB/4475 1N-L6) _ 0.39 < 1,33. OK (EQ C5.3) r • FROM : HARDESTY ASSOCIATES MATERIAL HANDLING ENG INEE RING TEL: (949) 889.0919 • FAX: (909) 8694981 161 ATLANTIC AVENUE • POMONA • CA 1768 VcokV/z= 51.0 L$ Movt =• (E F * hi) +1.15 - 9,064 IN SEE SEISMIC DISTRIBUTION Mst E (WDL + WLL)Vd /2 = 5 LEVELS * (25 LB /LVL + 120 LB /LVt. )' 12 IN/2 4,350 IN -LB Pupiif . (Moot. - Mst) /d • = (9064 IN -L3 - 4350 Cad- L8) /1Z in 393 LB ; '• . . . 114' MIN. EMBOMNT USE 1/4 IN IN DIAM. x 2 IN MIN. EMBED. HILT1 K II (I.C,6.0. #4627). PULLOUT CAPACITY= Z65 LB SHEAR CAPACITY- 400 LB # OF ANCHORS- 2 FAX NO. : 7609440399 Jun. 23 2073 04:25PM P9 • QVE_ ��____ RTURNi__NG(ANCHORAGE_„ANVALYSIS 12 ". DEEP UNIT PER DIV X, sEcTION 2228.7.1 PROJECT PACI f I C SUNWEAR Fon SHELF MASTER SHEET NO. ..._,..r. - _. OF 10 CALCULATED BY MYRON DATE 06- 21- 1999 EL .. S EL 4 EL F5 I. + h <�= AT LEAST 2. PER FRAME OR 4 PER UN1 i'. COMBINED STRESS: (392.8 LSI(2 *26S LB)) f(51 L8 /(Z *400 LB)) = 0.80 { 1.0 OK Fl # LEVELS 5 d= 12.0 IN H. $6 IN NO INSPECTION REQUIRED. FROM : HFIF.DESTY ASSOCIATES • MATERIAL. HANDLING ENGINEERING TEL: (909) 869.0889 • FAX: 1509) 869 -0891 161 ATLANTIC AVENUE • POMONA • CA 51768 Mconn �„ ^�»,q r��.b •....•_. CAPACITY OF STUD_ iN ValfOw= 0.4 *..Fy l AREA ,1.3 1,309 LE • • • Mallow= Vallow k d 1,964 Ifs FAX NO. : 7609440399 Jun. 23 2003 04:23PM P6 Mconn 6r, PROJECT._..._. „HECK„CAFAC1tY OF DOUBLE RIVET B A QNNECTION SINCE THE FRAME IS ASSUMED TO RESIST THE SEISMIC LOADS AS A MOMENT RESISTING FRAME, THE CAPACITY OF THE. RiVfwr Luz a SHALL 6F O ERMLNED. afiE:E r NO, 6 10 CALCULATED BY MYRON DATE _ 06 - 21 -1999 M_ cunq 4 \ 1 Vailow 0`-Z ° .....) \ 1 ..': • - fi OA_ Mlconn)I • 1 i 1 ' 4 " O t 4 , M. RIVE I @ 11,/'?- ARE.AY 0,049 INAZ Fy= 50,000 Ps; RECEIVED CITY OF TUte IAJ ft Ti A JUN 2 5 2003 PERMIT CENTER ' z 1F- • w Iz _J C.) O 0 N co w J N NLL w 0 J u. • d =W F- Z H O W H-_ • W U o � W W L I O w z. 1 O Z FROM : HARDESIY ASSOCIATES ANTI-TIP DEVICE CHECK MATERIAL HANDLING ENG INEERING TEL (909) 969-0989 • FAX: (909) 869•0991 161 ATLANTIC AVENUE • POMONA • CA 91786 Puptit. = 395 1.8 LIP LENGTH 1.000 IN UP WIDTH 12.00 IN LIP THICKNESS = 0.120 IN !:y = 33,000 PSl P(anti -tip) 39 LB M(tab) = P(antl- tip *d).• S - (bThA2) / 6 = 12 IN x (0.1196 1N) A2 / 6 — fb = M(tab) / S = 392.8 IN-LB / 0.0286 INA3 Eb = (0.6)1Fy 1 = 19,800 PSI fb /Fb ^ 13731,9 PS; ! 19800 PSI FAX NO. : 7609440399 Jun, 23 2003 04 :25PM P8 PROJECT PACI Fl C SUNWEAR hoH SHELF MASTER 393 x 1 IN = 392.85 IN -LB 0.0286 (N'3 13,732 PSI 0.69 < 1.0 ANTI -LIP IS OK SHEET N0. 8 OF 10 CALCULATED BY MYRON DATE 06- 21 -1 999 ,A tir;,' i :ay:i "v:; .:. za «K := z ^ntj .. t # M �, h;.. 3 ::, 7. ski ✓..' ?Ai r . x+ wn: ouv.. rr, a. a' G� ''Y•`�Y:.i?`+3i;�:� < «a�Yt, °iir FROM : HAPDFSTY ASSOC I RTES MATERIAL HANDL/NQ ENGINEEFi1Na TEL (909) A69.0949 • FAX: (909} 869-0 1381 iai ATLANT}C AVENUE - POMONA • CA 51988 SHELF LOAD(OI, +LL). 14S LB /LVL TOTAL SHELF AREA.- 576 IN TR16 AREA 8= 72 IN•q TRIE AREA A= 21G INr Z BEAM TYPE 1(A) LOAD. SHELF LOAD * (AREA A/TOTAL AREA) = 1.13 L$ /IN BEAM TYPE 20) LOAD SHELF LOA() la (AREA B/ TOTAL OT.A.L AREA) 1,51 LS /1N SHEET NO. «... .11111111 SHELF ANALYSIS THE SHELF SHALL BE ANALYZED TO DETERMINE THE ADEQUACY OF THE COMPONENTS TO CARRY THE GIVEN STA11C LOADS. ASSUME EIMPLY SUPPORTED END CONDITIONS. BEAM_TYPE 1 Tta /AMU wL "2/S (1.1 3 13/1N) `(4B)AZi 3 TA 326 IN-LE fb= M/S = 326.25 IN-L6/ Q.Q4. 1 NA3 7,749 PSI F U.6 *Fy = 0.6 * 36000 PSI = 21.600 PSI 0,36 •: 1,0 BEAM TYPE 1 OK FAX HO. : 7609440399 Jun. 23 2003 04:24PM P7 FOR SHELF MASTER Au= SWI A4/(384Ei) 51 - 133 LB/IN*(48 IN114/(384 *28X1 O P5}* INh4) = 0.110 IN 4ailcrw &-L/240 ge 0.200 IN OK BEAtELYELZSEE Mrnal = wLA2!3 27 IN-LB fb= MIS 646 PS1 Ft. 21,600 PSI fb /Fb� 0.03 1.0 BEAM TYPE 4 OK 7 OF 1 G MYRON 2 . 199 9 CALCULATED BY f7ATE SHELF SUPPORT .. w ,� trrr�m � ii'.�ivi: D.t�i'll•A. Y�dvL:•ti'X�4:..1�'iw'1in•/•. I RECEIVED CITY CIF T! pel + JUN 25 2003 PERMIT CENTEf, A.6 1/2" 1 BEAM TYPE 1: SRS, ix= 0 -0241 INA4 Sx. 0.0421 IN,'3 L= 48.0 IN REAM TYPE 2 :„SCI t Sx : 0,0421 INA3 L= 12.01N FROM : HARDESTY ASSOCIATES STORAGE RACKS DRJVE•W R. Xs CA.NT1LEVER RACKS M:22.ANINES CONVEYORS CAROUSELS PWHEACX RACKS RACx Mt DINGS 161 ATLANTIC STREET STEEL SHELVING MOVAt3L SHELY1NII STORAGE TANKS MODULAR OFFI+S 6CNO:?LAS 8OOKSTACKS FLOW RACKS FOOTINM FAX NO. : 7609440359 SE1ZMIC OHIO CAUFORNIA MATERIAL HANDLING ENGINEERING SEISMIC ANALYSIS ALAJtC4 IND14tU. 57AUCTUFAL DESIGN ARIZONA vim' S O IAtinMA CITY APrRpVALS u1 INgl� STATE AFr- T::ivAt,;, OREGON C4:.�?4C�4 MINNESOTA pE!�rLV>:tJl PRCQL� rSTlNG CONNfcrtcvr 41`.+S11UP: TEYA FIELD IN$r`6_: �tON GEORGIA „AHa �AH S GAL : AF¢!C.TION IDAHO t•� iAt?e vlk,;N1A DEMIT; mz Sa'RVICES ILUNt:t$ NEW !.F,XCA W4VING i ON vviSCONSIN SP:1S IC. AN.- LYSIS OF • SHELVING UNITS FOR PACIFIC .S I NWEAR ZONE 4, NEAR FAULT FACTOR = 1 JOB #:99.130)2 R.OV .:Q BY 1 E. FATEEN, 6/1 8'99 Jun. 23 2003 04 20P P1 POMONA • Ca • S1768 • 'TEL ' (909)869 -0989 • FAX : (909)869 -0981 REVISION NO. 1 CATY OF TUKWILA 'APPROVED JUL 0 2003 As 9OIEU 11304.4 pi■PtsZir z • z ce LIJ 6 0 O 0 CO W WI W u_ w 0 u.. • D 'T in z 1 ._ o z 1- LIJ n 0 a 1- L1J L I 0 z • u 1 O 1- z JUL — ®8 - 2003 09:02 I ATTACHMENT TO STRUCTURE ABOVE . SALE: s" , 1 AAD: nmowe� a MwK KA NA p.n.ld J. Huo w1N pas Koih N6 W tl N IM 3 5/b" X IbOA, METAL MOM AIT,!.01.1157 rcy IXIVIIN6 4" X 10' r4001, DEANS W/(4)2" WOOD 50IREM. —" • • L fitch !'XI5T. ROOT irmc.n,. YC.Rir 1 CXAGT GaHPI »IONS IN T1-6 r1rLD. I � 6" x Ibgge. METAL 9n • Lig" 0.0. ATTAGNNO TO 3 5/3 X ILEA. METAL 3 •/ (3) 1•10 sGRE1'Is AKElo Pt Cat•_AN YV (2) 2" Wooa OGR0e46. ` —.5 5/5' X toga. gT I �I a VP4 E 24" O,G, b' x Ib9Q. METAL 3TIm e O.G. ATTACH TO $ WV X I60A, '4!TAL vivo W/ (g) $IC saRoss AND TO 1 BEAM MV (2) 2' HOOP E.414E1'42.. D /8" X 200A. DW+6IGNAL MAC • \\ \ oar ATTA0H212 To 6" x 163A, MIN.. MO H/ (g) ' *OWNS, PROJECT: Pacaun i .. OAST. R00? =GK. VCRIPY WT GONGITIoNS N THO REC '", V;ginD WJL 2 c ?003 E DEPARTMENT LOCATION: Parkway ,S iper Center. Tukwila, WA. 1iTLI::Cunnectlon Details pROJECT# A03096 480 998 7223 P.01/01 5750 DWG: 1 JuL DATE: 07 -07-03 TOTAL P,01. 9/23/03 Dave Larson City Of Tukwila Building Department 6300 Southcenter Blvd. #100 Tukwila, WA 98188 RE: Pac Sun, Parway Super Center 17340 South Center Dr. Dear Dave: Sincerely, Hardesty & Associates, Inc. Irvine Office Scott D. Hardesty SDH /jm Enclosure •. HARDESTY & ASSOCIATES, INC. National General Contractors Specializing in Tenant Improvements 2102 Business Center Drive, Suite 130 Irvine, CA 92612 (949) 253 -4188 • Fax (949) 253 -4189 San Diego Office: 1516 Main Street, Suite 106 • Ramona, CA 92065 • (760) 789 -1210, Fax (760) 789 -1209 Enclosed is the revised engineered drawings for the rolling shelf system at the referenced location. The new drawings show the anti -tip rail at the center of the rolling units as assembled at the store. I hope this clarifies all the issues with the design and installation of this unit. Please call and let me know if we need any further information or if we can close this file out. ECEY J` D SP 2 BLIIL N DEPARTMENT Jai /37 z Q H w 00 WI U)o w 2 J u. ? a = w zF- HO Z I, 0- 01- w W 1- ..z w U= z September 17, 2003 Re: Pacific Sunwear #735 Tukwila, WA Dear Mr. Hardesty, chard Freiholtz Director of Retail Store Design and Sales RF/kg SHELF MASTER, INC. "Creating intelligent storage solutions" Here are the revised detail sheets showing anti -tip rail at one place (center rail) in the 96" carriage. Any questions please give me a call. Regards, 2831 E. Coronado Street, Anaheim, Califorgo 92806 Tel: (714) 632-5027 Tel: (800) 847-4353 Fax: (714) 632.5047 www.shelfmaster.com Stocking Distributors o: Rivetier • Sammons • Metro • Pacific • Rapid • Lyon • Akio-Mills . Nashville Wire • Ouik Pik • New and Pre-Owned Contractor Lic. #594012 • I I Hardesty + Associates National General Contractors Specializing in Tenant Improvements 5/20/03 Joanna Spencer City Of Tukwila Public Works 6300 Southcenter Blvd. #100 Tukwila, WA 98188 Sincerely, Hardesty & Ass • ciate ., In att Har esty COMMUNITY DEVELOPMENT Hardesty + Associates,inc. 2102 Business Center Drive Suite 130 Irvine, CA 92612 t (949) 253 -4188 f (949) 253 -4189 Phone: (206) 433 -0179 RE: Permit #D03 -139, Pac Sun, Parkway Super Center, Tukwila, WA RECEIVED MAY 21 2003 Dear Joanna: Per our conversation, I have figured for one new lavatory on the attached form. This is based on the fact that there are 2 toilets & 1 lavatory existing within the space, which are being replaced with 2 new toilets & 2 lavatories. Please call with any questions. Thank you. , May 14, 2003 Mr. Matt Hardesty Hardesty & Associates, Inc. 2102 Business Ctr. Dr., #130 Irvine, CA 92612 City of Tukw,'ila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: Letter of Incomplete Application #1 Development Permit Application Number D03 -139 PacSun —17340 Southcenter Parkway Dear Matt: This letter is to inform you that your permit application received at the City of Tukwila Permit Center on May 9, 2003, is determined to be incomplete. Before your application can begin the plan review process the following items need to be addressed: Public Works Department: Joanna Spencer, at (206) 433 -0179 if you have questions concerning the following: 1. Non - residential Sewer Use Certification (enclosed) needs to be filled out and signed by the owner /agent due to the addition of new plumbing fixtures an sheet A -2. Please list only the new fixtures. Please address the above comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 433 -7165. Sincerely, Stefania Spencer Permit Technician Enclosures File: Permit File No. D03 -9 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 1 ' Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dental units 1 1 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 I Sink, kitchen 3 2 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Water closet, tank or valve, 1.6 GPF 6 3 Water closet, tank or valve, >1.6 GPF 8 4 Non -F ;idential Sewer Use Certif •ation (To be completed for all new sewer connections, reconnections or change of use of existing connections. This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect.) Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. The charge is collected semi - annually. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King (206) 684 -1740. (Please print or type) (('"' ^ � II Property Tax ID # Z 4P 2 ti oq - ciU 7 -1 Owner's Name RIC g..ar (Gr 7• (Last, First, Middle Initial) , Party to be Billed (if different from owner) Subdivision Name Lot # Party's Mailing Address: E. 11V1 'rya'crn,t Ave. Subdiv. # Block # Building Name (if applicable) pD..G L) 1 PO24. XAY.StJ rCC*C. Property Street Address 11 .2,46 City, State, ZIP t iot , wiz% Owner's Phone Number ( 714 ) 14/ 1 -1- 4 1-0 - 15? Owner's Mailing Address (if different from above) 3450 E. yliVe t ion -Ave. A e_1v, , CA q2-3 A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units 20 RCE r For King County use: Account # Monthly Rate Six Month Due 1058 (Rev. 8/01) White — King County County's Wastewater Treatment Division at •411 • it . • in Q City or Sewer District 7 U KL/t/ /L Date of Connection !' Side Sewer Permit # £ O.3 x39 or Property Contact Phone # ( Demolition of pre- existing building? 0 Yes 0 No Type of building demolished /)//9 Sewer disconnect date B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) _ 187 C. Total Residential Customer Equivalents: A Mph (add A & B) RCE Signature of Owner /4f Representative Print Name of Owner/ Representative RCE I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Date Yellow — Local Sewer Agency Pink — Sewer Customer .+.,.•r.. PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP INS ACTIVITY NUMBER: D03 -139 PROJECT NAME: PAC SUN SITE ADDRESS: 17340 SOUTHCENTER PY Original Plan Submittal DATE: 06 -25 -03 Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Is Issued DEPARTMENTS: Building Division Public Works ❑ Fire Prevention i 7' 1"1 3 Structural ❑ DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Planning Division Permit Coordinator DUE DATE: 06 -26 -03 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R�TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS 0 CORRECTIONS: Approved Approved with Conditions 0 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DUE DATE: 07 -24 -03 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip,doc 2-28-02 PERMIT COORD COP • ••ipzci {V t ef". Vi P Documentthouting slip,doc 2.28 -02 PLAN R R�UTQN SLIP ACTIVITY NUMBER: D03 -139 PROJECT NAME: PAC SUN SITE ADDRESS: 17340 SOUTHCENTER PY DATE: 5 -21 -03 Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Buil� 41,0z/ -22--o3 ivlsion Public Works (0 n� J o,3 Fire Prevention Structural Complete ivr Incomplete TUES /THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: n C n � � Planr(ing Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 5-22 -03 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg DI Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 6-19-03 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: DEPARTMENTS: Complete ❑ APPROVALS OR CORRECTIONS: »ERMIT COOR.0 (� i3y PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D03 -139 PROJECT NAME: PACSUN SITE ADDRESS: 17340 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DATE: 05 -12 -03 Revision # After Permit Is Issued 5(0 /IWO 6- �-°3 Building Division 0 Fire Prevention Public orkstlii0.lf /-135 - Structural ❑ h/L 5 it Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05 -13 -03 Incomplete Not Applicable ❑ Comments: Permit Center Use Only _ INCOMPLETE LETTER MAILED: r 'i5� .�i LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW Staff Initials: .S-4S TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 06 -10 -03 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2-28-02 PERMIT COORD COPY DATE: 4JlM is iN, '3LU:+r.Yr t?, Revision No. I Date I Staff Received I Initials Date Issued Staff Initials I I I Summary of Revision: b ZS - 0 3 Received By: . Revision No. I Date I Received Staff 1 I Initials I Date Issued i • - Staff I Initials Summary of Revision: b ZS - 0 3 i Co I 7 -Z8 -' Q3 I 1.AJ Summary of Revision: `, , - - CZ ib c ry d �Y! -c„J ,c-LGN' ni /Jl.teic C4-- .0 GPQ -21.- L _ _ f Received By: Revision No. ' Date Received Staff Initials Date Issued Staff Initials Summary of Revision: Summary of Revision: Received By: Received By: Revision No. Date Received Stan Initials Date I Staff Issued Initials I I Summary of Revision: Received By: PROJECT NAME: �c a d Site Address: - REVISION LOG PERM! T 10 i)e v -/3 Original Issue Date: -9 O'3 t ptease print (please print) Revision No. Summary of Revision: Date Received Staff Initials Received By: Date Issued (please print) (please print) please print I Staff Initials of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ' ' ` . ' '" ' Plan Check/Permit Number: ! -/ O Response to Incomplete Letter # O Response to Correction Letter # (E Revision # f after Permit is Issued Project Name: fit\ C t NJ Project Address: 1 -I ? 3 . cso T t) Contact Person: Summary of Revision: ; l t 1 .. 14 I /q 1) + Tr) } - rsci + PEAWTcENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center bv: Entered in Sierra on Phone Number: is t i r- a PICENIo CITY OF TUKWILA JUN 252003 e 08 /30 /00 City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: PO J r /5e3 [ Response to Incomplete Letter # 0 Response to Correction Letter # 0 Revision # after Permit is Issued PA& 1194o `z ou.f i4v Mat -iii.e Summary of Revision: Project Name: Project Address: Contact Person: OA ' ate � .. ���J � i�� . I Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: g Entered in Sierra on lx bRrAgy.:y Y i t x.}v r: r' Phone Number: '�RYtS',N:J REr.FIVFn CITY OF TUKWILA MAY 212003 ID Ala1 i c :7 — \1 T FF 08/30/00 n+nxw.v+eK�CVtY,�t+.ft,�SS 5-032-000 (11197) • • S . • • rim" • REGISTERED AS PROVIDED BY LAW AS1 CONST CONT GENERAL • . . • . REGI ST . .• # • EXP . DATE CCO1 PHARDEI066PP 1.1 /02 /2003 EFFECTIVEi'..DATE .10/17/1994 - , HARDESTYWAS SOCIATES iINC. 1991 VILLAGE PARIC.WAY.7180 ' ENCINITAS .'CA . 92024 . . • 2 .:* I Sijiature " ' Issued by DEPARTMENT OF LABOR AND INDUSTRIES Please Remove And Sign Identification Card Before Placing In Billfold " .4st4414•44,16$44%4$411.,4'&..A.:Atij;lai,A4 'kg KEY PLAN PARKWAY .n....1/l,r..+. .•.n,., „ .,... we. wr .rn,.w.' . i VICINITY MAP TUCWLA, WASI#IKiTON ALTA. PROJECT LOCATION IIT.f. 4 114. linCILLANEOUS NOTE& • .................0,0....100 . * POW SPRINKLIIIIk .. • PARKWAY SUPER CENTER SPACE NO. 17340 17340 SOUTH CENTER PARKWAY TUKWILA, WASHINGTON DULDINCk MECHANICAL.: PLUMBINGt ELECTRICAL: HANDICAP: ENERGY: FEE E CONSTRUCTION TYPE M —N S. OCCUPANCY:. M (MERCANTILE) S LEAS PREMISE& 3,909 SQ. FT 1t OCCUPANT LOAD • TOTAL PROJECT DATA 1997 UNIFORM BUILDING CODE 1997 UNIFORM MECHANICAL CODE 1997 UNIFORM PLUMBING CODE 1999 NATIONAL ELECTRIC CODE 1998 CABO ANSI A117.1 2001 UNIFORM ENERGY CODE 1997 UNIFORM FIRE CODE t PROJECT NAME . . PACSWI 2. PROJECT DESCRIPTIOft . CLOTHING SALES (RETAIL) 3. PROJECT LOCATION PARKWAY SUPER CENTER 17340 SOUTH CENTER DRIVE SPACE NO. 17340 TUKWILA, WASHINGTON 4. TENANT:. PACIFIC SUMMAR STORES CORP. 3450 EAST MIRALOMA AVENUE ANAHEIM, CALIFORNIA 92806-2101 (714) 414 -4000 KIM BENNETT kbennett®pacificsunwear.com S. LANDLORD:. .. KINCO REALITY GROUP 5238 MANZANITA AVE. CARMICHAEL, CALIFORNIA 95608 CONTACT: BILL ANDREWS PHONE: (916) 349.7495 L ARCHITECT:.. . AAD : 15425 NORTH GREENWAY-HAYDEN LOOP, SUITE #100 SCOTTSDALE, ARIZONA 85260 PHONE: (602) 998 -4200 FAX: (602) 998 -7223 E -MAIL: shone_molnorOfitchww.com 7. QOVERNNIKI CODES: ALL WORK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED OF THE FOLLOWING: AND ANY OTHER STATE AND LOCAL CODES NUMBER OF OCCUPANTS = 106 TOTAL NUMBER OF EMPLOYEES AT ONE TIME = PUBLIC AREA: 3,075 S.F. - 30 = 103 NON PUBLIC AREA: 834 S.F. = 300 = 3 12. TWO (2) EXITS REQ., TWO (2) EXITS PROVIDED * EMT LL ATE .......... .............. EMERGENCY EXIT ILLUMINATION SHALL BE PROVIDED 1 IM UNCIPAL, REVIEW: _ .�..�.. DEVELOPRIEIT DEP 6300 SOUTH CENTER BLVD. TUKWILA, WASHINGTON 98188 CONTACT: BOB BENEDICTO PHONE: (206) 431.3670 TENANT'S GENERAL CONTRACTOR ING CONDITIONS PRIOR TO START CREPANCIES TO TENANT'S ARCHIT TENANT'S GENERAL CONTRACTOR ING CONSTRUCTION PROCEDURES, TO, THE REQUIREMENTS HAVING JURISDICTION. 3 AS SHOWN ON SHEET E2. SEPARATE PERMIT AND APPROVAL REQUIRED SHALL VISIT THE PREMISES AND VERIFY ALL EXIST - OF CONSTRUCTION AND SHALL REPORT ALL DIS- ECT. SHALL CONFORM TO ALL REQUIREMENTS REGARD - INSURANCE, ETC., AS SET FORTH BY THE LANDLORD • AN AUTOMATIC FIRE SPRINKLER SYSTEM IS EXISTING WITHIN THIS SPACE. THE CONTRACTOR SHALL REWORK AND MODIFY FOR NEW ROOM LAYOUT AND CEILING HEIGHTS IN CONFORMANCE WITH N.F.P.A. 13 STANDARDS AND LOCAL CODES & REGULATIONS. ALL WORK SHALL BE DONE BY A QUALIFIED SPRINKLER CONTRACTOR WHO SHALL DESIGN AND PREPARE SHOP DRAWINGS AND SUBMIT THEM TO THE LANDLORD FOR APPROVAL PRIOR TO FABRICATION AND INSTALL- ATION. SPRINKLER CONTRACTOR SHALL BE LANDLORD APPROVED. HEADS IN CEILING TILES TO BE CENTERED IN TILES WHEN IN A PUBLIC AREA. SPRINKLER HEAD TYPES: STOCK ROOM, TOILET ROOMS, OFFICE & HALLWAYS: SEMI RECESSED W/ CHROME ESCUTHEONS SALES AREA: SEMI RECESSED W/ CHROME ESCUTHEONS STOREFRONT SOFFIT: FULLY RECESSED W/ POP-OFF COVER (WHITE) • T SP1 SP2 SP3 D1 Al A2 A3 A4 AS A6 A7 A8 El E2 E3 ti SPECIFICATIONS DEMOLITION PLAN FLOOR PLAN INTERIOR ELEVATIONS MECHANICAL PLAN RESPONSIBLITY SCHEDULE REFLECTED CEILING PLAN SECTIONS AND DETALS SECTIONS AND DETALS SECTIONS AND DETALS Revtsolsts 'so CtiAtiCIES Stott. SE WI THE SCOPE OF Wow( vrikaTt404 0%1%4, P ppRt VM ' tom►- �' . ' 9 1. J ' is INDEX OF DRAWINGS TITLE sir FINISH SCHEDULES AND SPECIFICATIONS FIXTURE / FLOOR FINISH PLAN STOREFRONT ELEVATION AND SECTIONS MECHANICAL NOTES AID SPECS. PLUMBING PLAN, NOTES AND SPECS. ELECTRICAL POWER PLAN ELECTRICAL uoHrNG PLAN ELEcnRIcAu. sus, DIAGRAMS AND NOTES FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. SEPARATE PERMIT REQUIRED FOR: M ECHANICAL LECTRICAL LUMBING G PIPING CITY OF TUKWILA BU►LC1MG DIVISION Ci1YlIIMMJI IMOVED MAY 2 7 2003 &S NOIED fiit4t £4iHkif 1k6f rI�v -fD i Ye4frfifrw. eeiunt . OfTYOF TUKWILA MAY + 2t;c POUT CIDITER 735 ;OPYRIGI4T WHIM Thud drawings and specifications ore copyrighted and subject to copyright protection as on "architectural sorb` under Mc. 102 of Oho copyrigni act. 17 U.S.C. amended december 111110. the protection includes. w ith ou t IlmNotlert, the overell form. arrangement one composition of woos. and elomonts of the design. Under such protection, unauthorised use of nu m. drawings end specifications moy result In cossatlen of construction, building *sieure. and /or monetary liability. C 0 S/s g 11141" r :3° 1.12 a ILI it mg lag t ms EL p.m Pi• -.0 V +-1 • I a THE WORK INCLUDES NEW TENANT IMPROVEMENTS IN AN EXISTING MALL SPACE, PER SQUARE FOOT CALCULATIONS AS NOTED ON THE TITLE SHEET. CONTRACT WILL INCLUDE CONSTRUC- TING WALLS AND CEILINGS PER "PACIFIC SUNWEAR" STANDARD FINISHES, DETAILS & SPECIFICATIONS. SECURE AND PAY FOR GOVERNMENT FEES, LICENSES, AND PERMITS. 2. CONTRACTORS SHALL VISIT THE PREMISES WHILE BIDDING AND SHALL FAMILIARIZE THEM- DEVELOPING SELVES WITH EXISTING THEIR BID. CONDITIONS AND THE REQUIREMENTS OF THE PROJECT PRIOR TO MATERIAL QUANTITIES SHALL BE BASED ON ACTUAL FIELD CONDITIONS AND MEASUREMENTS. 00 NOT RELY oN SCALING PLANS FOR ACCURATE DIMENSIONING. 3. PRIOR TO BEGINNING THE WORK, VERIFY ALL EXISTING DIMENSIONS AND SQUARE FOOTAGES. NOTIFY THE OWNER OF COMPLIANCE OR DISCREPANCIES, COMPARING THOSE DISCREPANCIES TO THE NUMBERS ON THE TITLE SHEET. 4. CONTRACTORS SHALL TAKE CARE TO PROTECT ADJACENT AREAS FROM DUST AND DAMAGE DURING THE CONSTRUCTION PROCESS, AND SHALL CLEAN UP AFTER THEMSELVES AT THE END OF EACH WORKING DAY. 5. ALL RUBBISH AND TRASH SHALL BE REMOVED FROM THE PREMISES AND PROPERLY DISPOSED OF EACH DAY. NO RUBBISH SHALL BE LEFT IN THE PREMISES AFTER WORK IS COMPLETED EACH DAY. 6. ALL DRAWINGS HEREIN CREATE AN ENTIRE PACKAGE. ALL TRADES SHALL BE RESPONSIBLE FOR REVIEWING THEIR RESPECTIVE REQUIREMENTS AND COORDINATING THEIR HIDDEN OR EX- POSED WORK WITH OTHER RELATED TRADES. 7. COORDINATE ALL WORK OF THE VARIOUS TRADES AND SUBCONTRACTORS TO ASSURE EFFI- CIENT AND ORDERLY INSTALLATION. PROVIDE ACCOMMODATION FOR ITEMS INSTALLED AT A LATER DATE. VERIFY THAT CHARACTERISTICS OF ELEMENTS OF INTERRELATED OPERATING EQUIPMENT ARE COMPATIBLE; COORDINATE WORK OF VARIOUS SECTIONS WHICH HAVE INTERDE- PENDANT RESPONSIBILITIES FOR INSTALLING, CONNECTING TO, AND PLACING IN SERVICE, SUCH EQUIPMENT. COORDINATE SPACE REQUIREMENTS AND INSTALLATION OF MECHANICAL AND ELECTRICAL WORK AND FIRE SPRINKLER SYSTEM WHICH ARE INDICATED, DETAILED, OR IMPLIED DIAGRAMMATICALLY ON DRAWINGS. 8. UNLESS SPECIFICALLY NOTED, PROVIDE AND PAY FOR LABOR, MATERIALS AND EQUIPMENT, TOOLS, CONSTRUCTION EQUIPMENT AND MACHINERY, AND OTHER FACILITIES AND SERVICES NECESSARY FOR PROPER EXECUTION AND COMPLETION OF WORK, INCLUDING PERMITS. UTILITIES SHALL BE PROVIDED BY OWNER. 9. GENERAL CONTRACTOR SHALL PURCHASE AND MAINTAIN INSURANCE COVERAGE IN ACCOR- DANCE WITH THE REQUIREMENTS OF THE LANDLORD AND THE TENANT. VERIFY AND COOR- DINATE WITH THE TENANT'S PROJECT MANAGER, ANY ADDITIONAL REQUIREMENTS. 10. FURNISH ALL REQUIRED TEMPORARY FACILITIES AND ALL TEMPORARY UTILITIES IMMEDIATELY AFTER RECEIPT OF NOTICE TO PROCEED FOR USE IN CONVENIENCE OF ALL THOSE ENGAGED IN THE PROJECT WORK. 11. ALL CONTRACTORS MUST STAY BEHIND THE BARRIERS AND MAINTAIN ACCESS TO SUCH AREAS CLEAN AND FREE OF CONSTRUCTION MATERIALS AND DEBRIS. FAILURE TO MAINTAIN CLEAN STOREFRONT WILL RESULT IN BUILDING MANAGEMENT HAVING SUCH MATERIALS AND DEBRIS REMOVED AND ALL CHARGES FOR MAINTENANCE WILL BE BILLED TO GENERAL CONTRACTOR. 12. COORDINATE ALL CONSTRUCTION & SCHEDULING WITH THE BUILDING MANAGER REVIEWING ALL SCHEDULED ACTIVITIES AT OUTSET OF CONSTRUCTION: 13. ALLOWABLE TOLERANCES -- UNLESS OTHERWISE NOTED OR INDICATED, THE FOLLOWING TOLER- ANCES SHALL APPLY TO ALL WORK: a. ALL VERTICAL SURFACES SHALL BE PLUMB OR CONSTRUCTED TO THE EXACT SLOPES OR ANGLES INDICATED. b. THE MAXIMUM DEVIATION FROM THE TRUE PLANE FOR VERTICAL AND HORIZONTAL SURFACES SHALL NOT BE GREATER THAN 1/8" IN 10' --0" AS MEASURED BY A STRAIGHT EDGE PLACED ANYWHERE ON THE SURFACE. c. ALL HORIZONTAL SURFACES SHALL BE LEVEL OR CONSTRUCTED TO THE EXACT ANGLE INDICATED OR INTENDED. d. WALL AND SOFFIT INTERSECTIONS SHALL BE 90 OR THE EXACT ANGLE INDICATED OR INTENDED. e. ALL CORNERS AND EDGES SHALL BE STRAIGHT AND TRUE WITHOUT DENTS, WAVES OR BULGES OR OTHER BLEMISHES. ALL JOINTS SHALL BE TIGHT, STRAIGHT, EVEN AND SMOOTH. ALL OPERABLE ITEMS SHALL OPERATE SMOOTHLY WITHOUT STICKING OR BINDING AND WITHOUT EXCESSIVE "PLAY" OR LOOSENESS. f. 9. 14. THE FOLLOWING MATERIALS SHALL BE LEFT AT JOBSITE. THEY SHALL BE TAKEN FROM THE SAME MATERIAL, LOT OR RUN USED TO CONSTRUCT AND FINISH THE PROJECT: a. SIX YARDS OF CARPET. (IF USED) b. FOUR FULL LENGTH STRIPS OF RUBBER BASE. c. FOUR FULL CEILING TILES OF EACH TYPE. d. 1 QUART OF EACH COLOR PAINT IN A TIGHTLY SEALED AND MARKED CAN. MATERIALS SHALL BE LEFT IN ONE LOCATION UPON OWNER'S REPRESENTATIVE'S DIRECTION AND APPROVAL. 15. THE OWNER OR THE OWNER'S SUBCONTRACTORS MAY OCCUPY PORTIONS OF THE PROJECT DURING THE FINAL STAGE OF CONSTRUCTION. COORDINATE AND COOPERATE WITH THE OWNER TO MINIMIZE CONFLICT AND FACILITATE THE OWNER'S OPERATION. 16. ALL DIMENSIONS AND FINISHES SHALL BE VERIFIED AND COORDINATED WITH EXISTING CON- DITIONS PRIOR TO CONSTRUCTION, FABRICATION, OR PURCHASING. IN CASE OF CONFLICT BE- TWEEN THE PROJECT REQUIREMENTS AND /OR EXISTING CONDITIONS, THE ONE HAVING THE MOST STRINGENT REQUIREMENTS SHALL GOVERN, AS APPROVED BY THE OWNER. 17. PERFORM ALL WORK IN ACCORDANCE WITH ACCEPTABLE TRADE PRACTICE TO INSURE THE HIGHEST QUALITY FINISHED PRODUCT - EXPRESSED OR IMPLIED. PERFORM ALL WORK BY SKIL- LED MECHANICS IN ACCORDANCE WITH ESTABLISHED STANDARDS OF WORKMANSHIP IN EACH OF THE VARIOUS TRADES. 18. COORDINATE BLOCKING REQUIREMENTS WITH ADJACENT OR RELATED TRADES, ACCESSORIES, EQUIPMENT & FIXTURES INSTALL REQUIRED BLOCKING AT NO ADDITIONAL COST TO THE CONTRACT. 19. REPAIR PROPERTY DAMAGE BY THE INSTALLERS TO A LIKE NEW CONDITION OR REPLACE DAMAGED SURFACES AND MATERIALS OF THE PREVIOUSLY INSTALLED WORK BY OTHER TRADES, INSTALLERS AND SUBCONTRACTORS. 20. WHERE REQUESTED BY THE OWNER TO CERTIFY CONFORMANCE TO TRADE STANDARDS OR THE PROJECT REQUIREMENTS, THE CONTRACTOR SHALL ENLIST A TESTING LABORATORY AT THE OWNER'S COST. IF THE REQUESTED TEST SHOWS NON - CONFORMANCE TO GENERALLY ACCEPTED TRADE STANDARDS OR THE PROJECT REQUIREMENTS, THE CONTRACTOR SHALL CORRECT THE DE- FICIENCY AT NO ADDITIONAL COSTS TO THE OWNER AND REIMBURSE ALL THE COSTS OF THE TESTING TO THE OWNER, UNLESS THE CONTRACTOR HAS USED PRODUCTS INCORRECTLY LABELED BY THE MANUFACTURER OR HAS MADE PREVIOUSLY APPROVED CHANGES. 21. PROVIDE SECURITY OF THE WORK, INCLUDING TOOLS AND UNINSTALLED MATERIALS. PROTECT THE WORK, STORED PRODUCTS, CONSTRUCTION EQUIPMENT AND OWNER'S PROPERTY FROM THEFT AND VANDALISM AND THE PREMISES FROM ENTRY BY UNAUTHORIZED PERSONNEL UNTIL FINAL ACCEPTANCE BY OWNER. 22. MAINTAIN AN ACTIVE FIRE EXTINGUISHER AT THE PROJECT. 23. DO NOT USE MATERIAL OR EQUIPMENT FOR ANY PURPOSE OTHER THAN THAT FOR WHICH IT IS SPECIFICALLY DESIGNED OR SPECIFIED. ALL MATERIALS AND EQUIPMENT THAT ARE SIMILAR SHALL BE THE SAME TYPE, MODEL, AND STYLE FOR THE SAME USE THROUGHOUT THE PRO- JECT OR THEY SHALL BE REJECTED. 24. WHEN THE PROJECT REQUIREMENTS REQUIRE THAT THE INSTALLATION OF WORK SHALL COMPLY WITH MANUFACTURER'S INSTRUCTIONS, PERFORM THE WORK IN STRICT ACCORDANCE WITH THE MOST CURRENT WRITTEN MANUFACTURER'S INSTRUCTIONS. 25. ALL PRODUCTS AND EQUIPMENT SHALL BE DELIVERED IN UNDAMAGED CONDITION AND STORED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS TO AVOID DISRUPTION OF THE WORK OR DAMAGE TO THE ITEMS. REPLACE DAMAGED OR UNFIT MATERIALS, AT NO COST TO THE OWNER. 26. NOTIFY THE OWNER WHEN THE WORK IS SUBSTANTIALLY COMPLETE AND READY FOR FOR IN- SPECTION. UPON INSPECTION, PROVIDE WRITTEN OPERATION AND MAINTENANCE INSTRUCTIONS AND GUARANTEES FOR ALL EQUIPMENT AND MATERIALS INSTALLED. PROVIDE WRITTEN GUAR- ANTEES FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE OF THE WORK. 27. PROVIDE FINAL CLEAN -UP AND DAMAGE REPAIR AT THE PROJECT CONCLUSION. LEAVE THE PREMISES NEAT, CLEAN AND CLEAR OF TOOLS, EQUIPMENT AND SURPLUS MATERIALS, UN- LESS REQUESTED BY THE OWNER. CLEAN -UP SHALL INCLUDE AND NOT BE LIMITED TO: a. POWER VACUUMING THE ENTIRE SPACE. HAND DUSTING AND CLEANING OF ALL SHELVING, CABINETRY, CASEWORK, GLASS AND MIRRORS BOTH INSTALLED UNDER THIS CONTRACT OR EXISTING WALLS, CEILINGS, FIXTURES, ETC. C. REPAIR OR REPLACEMENT OF PROPERTY DAMAGED DURING FINAL COMPLETION OF THE PROJECT. b. on�ow : • orour� i rae�ro ut■urera 1. THE WORK MAY INCLUDE DEMOLITION OF EXISTING CONSTRUCTION, REMOVAL OF VARIOUS ITEMS OF EQUIPMENT AND CONSTRUCTION, AND THE CUTTING OR ALTERATION OF EXISTING CONSTRUCTION AS SHOWN, NOTED OR IMPLIED ON THE DRAWINGS. CONTRACTOR SHALL DE- TERMINE AND INVENTORY ALL NECESSARY DEMOLITION AND ALTERATION OF ITEMS TO PRO- VIDE FOR A COMPLETE INSTALLATION OF NEW WORK. ALL COSTS OF REMOVAL, REPAIR OR REPLACEMENT SHALL BE INCLUDED IN THE BID. ADDITIONAL COSTS FOR DEMOLITION OF ITEMS HIDDEN OR INACCESSIBLE DURING THE BIDDING PHASE, SHALL BE SUBMITTED FOR APPROVAL PRIOR TO BEGINNING THE WORK. 2. AT ALTERED CONSTRUCTION, REPAIR CUT EDGES, REPLACE CONSTRUCTION, AND FIT NEW TO EXISTING CONSTRUCTION TO MATCH EXISTING WORK. MAKE JOINTS OF NEW AND EXISTING PATCHES VERY SMOOTH, EVEN AND PRACTICALLY INVISIBLE. COORDINATE ALL REPLACEMENT AND REPAIR REQUIREMENTS WITH LANDLORD'S CONSTRUCTION CRITERIA AND TENANT'S CO- ORDINATOR. 3. SAW -CUT CONCRETE WITH DIAMOND SAW; JACKHAMMERING WILL NOT BE PERMITTED EXCEPT WITH THE EXPRESSED WRITTEN APPROVAL OF THE LANDLORD. CUT IN ACCURATELY LOCATED, STRAIGHT LINES, AND BREAK OUT SECTIONS. FLOOR MAY BE CORE DRILLED WHERE APPROP- IATE FOR INSTALLATION OF PIPES AND SIMILAR ITEMS. COORDINATE ALL CORE LOCATIONS AND SLAB MODIFICATIONS WITH LANDLORD'S STRUCTURAL ENGINEER. WHERE EXISTING PIPING AND OTHER SIMILAR ITEMS ARE UNDER EXISTING SLABS, EXERCISE CARE TO PROTECT FROM DAMAGE. EXERCISE CARE WHEN CUTTING ADJACENT TO EXISTING WALLS TO AVOID DAMAGE TO WALLS. IF DAMAGED, REPAIR AS REQUIRED TO ORIGINAL CONDITION. 4. DOORS & FRAMES: IF DOORS AND FRAMES ARE TO BE REUSED ON THE WORK, CAREFULLY REMOVE DOOR FROM FRAMES AND REMOVE FRAMES FROM OPENING, TAKING CARE TO AVOID DAMAGE. REMOVE HARDWARE, CLEAN, REFURBISH, AND STORE FOR REINSTALLATION WHERE INDICATED. FOR DOORS AND FRAMES TO BE SALVAGED, CAREFULLY REMOVE FROM OPENING AND DELIVER FOR STORAGE WHERE INDICATED. 5. PREVENT MOVEMENT OR SETTLEMENT OF STRUCTURE. PROVIDE AND PLACE BRACING AND SHORING AND BE RESPONSIBLE FOR SAFETY AND SUPPORT OF STRUCTURE, AS DETERMINED BY G.C. ENLISTED STRUCTURAL ENGINEER. ASSUME LIABILITY FOR SUCH MOVEMENT, SETTLEMENT DAMAGE OR INJURY. 6. ARRANGE AND PAY FOR DISCONNECTING, REMOVING AND CAPPING UTILITY SERVICES WITHIN AREAS AFFECTED BY DEMOLITION. PLACE MARKERS TO INDICATE LOCATION OF DISCONNECTED SERVICES. LOCATE SPRINKLER SHUT -OFF VALVE AND SMOKE ALARM PRIOR TO COMMENCING WORK; COORDINATE REQUIRED MODIFICATION WITH LANDLORD. 7. CAREFULLY REMOVE MATERIALS AND EQUIPMENT WHICH ARE INTENDED TO BE REUSED. STORE IN A SECURE LOCATION. REMOVE DEBRIS, REFUSE AND MATERIALS BEING DEMOLISHED IM- MEDIATELY FROM THE SITE. 8. ERECT AND MAINTAIN WEATHERPROOF AND DUSTPROOF CLOSURES AND PARTITIONS TO PRE- VENT WEATHER DAMAGE OR SPREAD OF DUST, FUMES AND SMOKE TO OTHER PARTS OF THE BUILDING, IN ACCORDANCE WITH MALL GUIDELINES AND STIPULATIONS. 9. PERFORM DEMOLITION IN ACCORDANCE WITH APPLICABLE AUTHORITIES HAVING JURISDICTION. 10. REPAIR ALL DEMOLITION IN EXCESS OF THAT REQUIRED AT NO COST TO THE OWNER. 11. REMOVE FROM SITE CONTAMINATED, VERMIN INFESTED OR DANGEROUS MATERIALS ENCOUNTERED; DISPOSE OF BY SAFE MEANS TO PROTECT HEALTH OF WORKERS AND PUBLIC. DIVISION 3 - CONCRETE REPAIR & REPLACEMENT 1. WORK INCLUDES PATCHED, DEMOLISHED SLAB AND CERAMIC TILE, IF ANY; FILLING AND LEVELING JOINTS AND CRACKS; AND FILLING ABANDONED ELECTRICAL BOXES AND ANY HOLES GREATER THAN 1/2". 2. USE RAECO -LITH "R -35" AS UNDERLAYMENT FOR PATCHING OR APPROVED EQUAL. MIX SHALL BE TWO PARTS - MORTAR MIX AND LATEX BINDER. MIX AND INSTALL PER MANU- FACTURER'S LATEST WRITTEN AND RECOMMENDED DIRECTIONS. I. GENERAL 1. THIS PRODUCT IS LIGHTWEIGHT IN NATURE AND WILL NOT IMPOSE A SIGNIFICANT LOAD ON THE EXISTING FLOOR SLAB. A. DESCRIPTION 1. A PORTLAND CEMENT - BASED, SELF - DRYING, SELF - LEVELING CEMENTITIOUS TOPPING IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 2. PROVIDE LABOR, MATERIAL, EQUIPMENT, AND SERVICES NECESSARY TO COMPLETE THE CEMENTITIOUS TOPPING WORK AS HEREIN SPECIFIED. B. QUALIFICATIONS 1. INSTALLATION OF THE CEMENT - BASED, SELF - DRYING, SELF - LEVELING TOPPING MUST BE BY AN APPLICATOR USING MIXING EQUIPMENT AND TOOLS APPROVED BY THE MANUFACTURER. C. APPLICATIONS 1, AFTER PROPER PREPARATION, TOPPING SHALL BE SUITABLE OVER NEW OR OLD INDOOR CONCRETE: UNFINISHED, ROUGH, RAINED -ON, FROZEN, SPALLED OR OTHERWISE DETERIORATED CONCRETE. D. DELIVERY, STORAGE AND HANDLING - DELIVER MATERIALS IN THEIR UNOPENED PACKAGES AND PROTECT FROM EXTREME TEMPERATURES AND MOISTURE. PROTECT LIQUIDS FROM FREEZING. II. PRODUCTS A. MATERIALS 1. WATER SHALL BE CLEAN, POTABLE, AND SUFFICIENTLY COOL (NOT WARMER THAN 700F). III. EXECUTION FLOOR CON DTE T OPPOKI i A. TOPPING SHALL BE ABLE TO BE INSTALLED 1/16" TO 1/4" IN ONE POUR, BUT MAY BE TAPERED TO MATCH THE EXISTING ELEVATION. B. TOPPING MATERIAL SHALL ACHIEVE COMPRESSIVE STRENGTH OF 6100 PSI AFTER 28 DAYS PER ASTM C109 MOD. C. TOPPING SHALL BE WALKABLE AFTER 2 -3 HOURS AT 700F, AND BE ABLE TO BE SEALED WITH A WATERBOME COATING AS SOON AS IT CAN BE WORKED ON WITHOUT DAMAGE. IN ADDITION TO THE GENERAL PROCEDURES DESCRIBED HEREIN, REFER TO THE MANUFACTURER'S CURRENT PUBLISHED PRODUCT LITERATURE FOR COMPLETE INSTALLATION DETAILS FOR THE MATERIAL BEING INSTALLED. A. PREPARATION 1. ALL STANDARD ABSORBENT CONCRETE SURFACES MUST BE SOUND, SOLID, CLEANED, AND PRIMED. SPECIFICATIONS I -ND ?(I 0111�OH f - 1lTAL iAUUCATIOI 1. PROVIDE ALL MISCELLANEOUS METAL ITEMS INCLUDING MATERIALS, FABRICATIONS, FASTEN- INGS, AND ACCESSORIES REQUIRED FOR FINISHED INSTALLATION AS INDICATED AND SPEC- IFIED. 2. STEEL SHALL BE ASTM A366 AMERICAN OPEN HEARTH SHEET STEEL, FREE FROM SCALE AND PITTING AND OTHER DEFECTS AFFECTING APPEARANCE. 3. TUBING SHALL CONFORM TO REQUIREMENTS OF ASTM A500 OR A501 AS APPROVED. 4. WHERE METAL ITEMS ARE TO BE ERECTED AND IN CONTACT WITH DISSIMILAR MATERIALS, PROVIDE CONTACT SURFACES WITH COATING OF AN IMPROVED ZINC CHROMATE PRIMER IN MANNER TO OBTAIN NOT LESS THAN 1.0 MIL DRY FILM THICKNESS. 5. SHEET STEEL SHALL CONFORM TO REQUIREMENTS OF ASTM A606. 6. CARBON STEEL BARS SHALL CONFORM TO REQUIREMENTS OF ASTM A321. 7. ALUMINUM EXTRUSIONS SHALL CONFORM TO ASTM B221. REVEALS TO BE BLACK ANODIZED FINISH. (UNLESS OTHERWISE NOTED) 8. FASTENERS SHALL BE AS REQUIRED FOR ASSEMBLY AND INSTALLATION OF FABRICATED ITEMS. 9. BOLTS SHALL BE LOW CARBON STEEL EXTERNALLY AND INTERNALLY THREADED FASTENERS CONFORMING WITH REQUIREMENTS OF ASTM A307; INCLUDE NECESSARY NUTS AND PLAIN HARDENED WASHERS. FOR MEMBERS FOR SUPPORT OF STRUCTURAL MEMBERS OR CONNEC- TION THERETO, USE FASTENERS CONFORMING WITH ASTM A325. FOR STAINLESS STEEL AND NON- FERROUS ITEMS, USE TYPE 302 AND 304 STAINLESS STEEL FASTENERS. 10. MISCELLANEOUS MATERIALS: PROVIDE ALL INCIDENTAL ACCESSORY MATERIALS, TOOLS, METHODS, AND EQUIPMENT REQUIRED FOR FABRICATION AND INSTALLATION OF MISCELLAN- EOUS METAL ITEMS AS INDICATED ON DRAWINGS. 11. VERIFY DIMENSIONS PRIOR TO FABRICATION OR CASTING. FORM METAL ITEMS TO ACCURATE SIZES AND CONFIGURATIONS AS INDICATED ON DRAWINGS AND OTHERWISE REQUIRED FOR PROPER INSTALLATION; FABRICATE WITH ALL LINES STRAIGHT AND ANGLES SHARP, CLEAN AND TRUE; DRILL, COUNTERSINK, TAP, AND OTHERWISE PREPARE ITEMS FOR CONNECTION WITH WORK OF OTHER TRADES. MAKE PERMANENT CONNECTIONS BY WELDING AND GRIND ALL EXPOSED WELDS SMOOTH TO MATCH ADJACENT SURFACES; ROUGH JOINT SUR- FACES NOT PERMITTED. AVOID USING BOLTS AND SCREWS UNLESS SPECIFICALLY INDICATED OR APPROVED; WHEN USED, DRAW UP TIGHT AND TIE THREADS TO PREVENT LOOSENING. 12. ALL FERROUS METAL ITEMS SHALL BE SHOP FINISHED. TOUCH -UP OR REPAIR DAMAGED AREAS PRIOR TO INSTALLATION WITH SAME MATERIAL. 13. PROVIDE CONTACT SURFACES WITH CONCRETE MASONRY OR OTHER DISSIMILAR MATERIALS WITH A MINIMUM ONE POINT ZERO (1.0) MIL DRY THICKNESS OF AN APPROVED ZINC CHRO- MATE PRIMER. 14. PROVIDE ALL STEEL BLOCKING AND BRACING IN METAL STUD FRAMED PARTITIONS NECESSARY FOR A COMPLETE INSTALLATION. INCLUDE AS REQUIRED FOR SUPPORT OF ALL WALL - MOUNTED EQUIPMENT AND FABRICATIONS AS INDICATED ON DRAWINGS. PROVIDE SUPPORTS AT JAMBS OF DOORS AND ELSEWHERE, AS REQUIRED. 15. FABRICATE ALL MISCELLANEOUS FRAMING AND BRACING ITEMS TO DETAIL OF STRUCTURAL SHAPES, PLATES, AND BARS; WELD JOINTS WHERE PRACTICAL; PROVIDE BOLTS AND OTHER CONNECTION DEVICES REQUIRED. INCLUDE ANCHORAGES, CLIP ANGLES, SLEEVES, ANCHOR PLATE, AND SIMILAR DEVICES, WHETHER IMPLIED OR INDICATED. SET ACCURATELY IN POSITION AS REQUIRED AND ANCHOR SECURELY TO BUILDING CONSTRUCTION WITH FAST- ENERS APPROPRIATE TO THE INSTALLATION. DIVISION 6 - WOOD I PLASTICS 1. PROVIDE ROUGH LUMBER AND PLYWOOD IN STANDARD DIMENSIONS. MOISTURE CONTENT NOT MORE THAN 19%. 2. PROVIDE ALL NECESSARY ROUGH HARDWARE IN SIZES IN QUANTITIES REQUIRED BY LOCAL CODE OR APPROVED BY ARCHITECT. 3. USE FINISH OR CASING NAILS FOR EXPOSED WORK; USE TYPE "S" TRIM HEAD SCREWS FOR ATTACHMENT OR WOOD TRIM TO METAL STUDS, RUNNERS, OR FURRING. 4. RELIEVE BACKS OF WOOD TRIM; KERF BACKS OF MEMBERS MORE THAN 5" WIDE AND 1" NOMINAL THICKNESS; EASE ALL EXTERNAL CORNERS. 5 INSTALL LAMINATES ONLY WHEN RECEIVING SURFACES ARE IN A SATISFACTORY CONDITION FOR INSTALLATION. 6. USE ADHESIVES RECOMMENDED BY THE MANUFACTURER FOR THE PARTICULAR APPLICATION; INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOST CURRENT PRINTED APPLICATION IN- STRUCTIONS. 7. PROTECT FROM DAMAGE BY OTHER TRADES WORKING ADJACENT TO THE INSTALLATION. RE- PLACE DAMAGED SURFACES. 8. REMOVE EXCESS ADHESIVE AND CLEAN SURFACES USING MANUFACTURER'S RECOMMENDED SOLVENT AND CLEANING PROCEDURES. 9. FILL IN ALL SEAMS WITH MANUFACTURER'S APPROPRIATE COLOR SEAM COMPOUND. 10. INSTALL WOODS AND PLASTICS IN CONFORMANCE WITH DETAILS, WITH THE FOLLOWING CON- SIDERATIONS AND REQUIREMENTS: a. INSTALL ALL MATERIAL WITH TIGHT JOINTS. b. MITER CASINGS AND MOLDINGS. c. ALL RUNNING TRIM ONE (1) PIECE UP TO 10' -0 ". MATCH GRAIN AND COLOR PIECE - TO PIECE. d. USE FINISH NAILS EXCEPT WHERE SCREWS ARE SPECIFICALLY CALLED FOR OR WHERE SCREWS DO NOT SHOW. e. SET FASTENERS FOR PUTTYING. f. WHERE SCREW ATTACHMENT REQUIRED, SPACE SCREWS AT EQUAL INTERVALS; SINK AND PUTTY IN FINISH WOOD SURFACES. 9. ALL MEMBERS AND LINES LEVEL AND PLUMB. h. SELECT AND CUT MATERIAL TO EXCLUDE DAMAGED, MARKED, OR DEFECTIVE AREAS. i. FINISH EXPOSED SURFACES SMOOTH, FREE FROM TOOL AND MACHINE MARKS. j. EASE ALL EXPOSED WOOD EDGES 1/8" MINIMUM RADIUS. k. INSTALL FIRE RATED DOORS IN ACCORDANCE WITH REQUIREMENTS OF NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) RECOMMENDATIONS. 11. ALL WOOD BLOCKING, FRAMING, PLYWOOD, ETC. SHALL BE FIRE RETARDANT TREATED. ruara m caa 1. PROVIDE NON -SAG SEALANT COMPLYING WITH REQUIREMENTS OF FEDERAL SPECIFICATIONS TTS -1543 OR FS TT -S -230 TYPE "II ", CLASS "A ". PROVIDE ACOUSTICAL SEALANT WHICH SHALL BE NON- HARDENING, NON- DRYING SYNTHETIC RUBBER SEALING COMPOUND WITH MIN- IMUM 907E SOLIDS. USE AT ALL INTERIOR JOINTS AT INNER SECTIONS BETWEEN PLANES. AROUND DOOR AND WINDOW FRAMES PRIMER SHALL BE MADE OR RECOMMENDED BY SEALANT MANUFACTURER FOR THE SPECIFIC CONDITIONS AND SUBSTRATES. 2. PROVIDE BACKING MATERIAL BY DOW "ETHAFOAM" OR APPROVED EQUAL. APPLY SEALANT OVER BACKING TO UNIFORM THICKNESS IN CONTINUOUS BEADS FILLING ALL JOINTS AND VOIDS SOLID. SUPERFICIAL POINTING WITH THE SKIM BEAD WILL NOT BE ACCEPTED. 3. ALL SURFACES SHALL BE ADEQUATELY CLEANED AND PREPARED IN ACCORDANCE WITH MAN- UFACTURER'S WRITTEN INSTRUCTIONS PRIOR TO INSTALLATION. ,ONION S - WOOD a HOLLOW METAL. DooAS a PRAMS 1. PROVIDE "TIMELY" KNOCKDOWN DOOR FRAMES AT ALL G.C. PROVIDED DOORS, FREE FROM SCALE AND PITTING AND OTHER SURFACE DEFECTS, UNLESS OTHERWISE NOTED. 2. PROVIDE HOLLOW METAL EXIT DOOR CONSTRUCTED WITH THE FOLLOWING MATERIALS: - MINIMUM 18 GA. FOR FACE SHEETS OF INTERIOR DOORS - 16 GA. FOR EDGE CHANNELS. - MINIMUM 22 GA. FOR FACE STIFFENERS. - MINIMUM 16 GA. FOR INTERIOR FRAMES. 3. PROVIDE DOORS OF SIZES AND TYPES INDICATED ON DRAWINGS, FULLY WELDED SEAMLESS CONSTRUCTION WITH NO VISIBLE SEAMS OR JOINTS ON FACES OR VERTICAL EDGES; THICK- NESSES AS SCHEDULED ON DRAWINGS. 4. FACE STIFFENERS, EDGES AND HARDWARE REINFORCEMENT SHALL BE THE HIGHEST QUALITY WORKMANSHIP AND MATERIALS. PROVIDE IN ACCORDANCE WITH BEST TRADE PRACTICE AND MANUFACTURER'S WRITTEN RECOMMENDATIONS FOR THE USE INTENDED. 5. PROVIDE CUSTOM MADE WELDED UNITS WITH INTEGRAL TRIM; SIZES AND SHAPES AS INDICATEL+ ON DRAWINGS; FABRICATE UNITS SQUARE, TRUE AND FREE FROM DEFECTS. 6. HARDWARE REINFORCEMENT AND ANCHORS (ERECTION, FLOOR AND JAMB) SHALL BE AS RE- QUIRED FOR A SECURE INSTALLATION AND SHALL BE IN ACCORDANCE WITH TRADE REQUIRE- MENTS FOR THE SPECIFIED HARDWARE AND INTENDED USE. 7. AFTER FABRICATION, DRESS, FILL AND SAND EXPOSED SURFACES, BODY -PUTTY HOLES AND IMPERFECTIONS. APPLY UNIFORM COAT OF MANUFACTURER'S STANDARD PRIME COAT TO ALL EXPOSED SURFACES. LEAVE READY TO RECEIVE FINISH PAINTING. 8. INSTALL FRAMES IN ACCURATE LOCATIONS AS INDICATED ON DRAWINGS. INSTALL RIGID, PLUMB, LEVEL, AND TRUE. ALIGN WITH ADJACENT CONSTRUCTION. SECURE FLOOR ANCHORS TO FLOOR CONSTRUCTION WITH APPROVED TYPE MECHANICAL FASTENINGS; ANCHOR TO ADJOINING WALLS WITH SPECIFIED ANCHORS. BRACE FRAMES TO RETAIN POSITION AND CONTINUOUSLY CHECK ALIGNMENT DURING CONSTRUCTION OF ADJACENT WALLS. ADJUST FRAME LOCATIONS AS NE- CESSARY USING SHIMS BEFORE FASTENING. LEAVE READY TO RECEIVE SEALANT WHERE IN- DICTATED ON DRAWINGS. 9. INSTALL WOOD DOORS, FRAMES, AND TRIM. SIZES AND THICKNESS AS SCHEDULED ON THE DRAWINGS. 10. PREPARE DOORS FOR FINISH HARDWARE. OBTAIN TEMPLATES FROM HARDWARE MANUFACTURER AND CONFIRM TYPE, LOCATION, AND SPECIAL REQUIREMENTS OF HARDWARE FOR EACH DOOR PRIOR TO CUTTING. 11. HANG DOORS AS SCHEDULED ON DRAWINGS, IN ACCURATE LOCATIONS WITH 1/8" CLEARANCE AT TOPS AND 3/8" CLEARANCE AT BOTTOM, UNLESS SPECIFICALLY NOTED FOR "UNDERCUTS" OR OTHER DEVIATIONS IN FIT. VERIFY CLEARANCES REQUIRED FOR CARPETING AND MAKE NO JOBSITE FIT IN CUTS UNLESS APPROVED. HANG PAIRS OF DOORS AS SPECIFIED WITH 3/32" CLEARANCE AT MEETING EDGES. DEMONSTRATE THAT DOORS OPEN FREELY WITHOUT BINDING, AND WHEN CLOSED, WILL LATCH PROPERLY. 12. ACCESS DOORS (PROVIDED BY GENERAL CONTRACTOR): PROVIDE ACCESS DOORS BY MILCOR OR EQUAL. USE STYLE DW AT WALLS AND CEILINGS, (OR AS REQUIRED FOR RATING). SIZE AS INDICATED. FRAME SHALL BE GALVANIZED STEEL DRYWALL BEAD FOR FRAME CONCEALMENT. PANEL SHALL BE 140A. STEEL WITH SPRINT TYPE CONCEALED HINGES OPENING TO 175 DEGREES. LOCKS SHALL BE FLUSH, SCREWDRIVER OPERATED WITH METAL CAN. PRIME COAT SHALL BE FACTORY APPLIED. COORDINATE INSTALLATION WITH REQUIREMENTS OF OVERHEAD COILING DOOR MANUFACTURER. HARDWARE 1. ALL FINISH HARDWARE FOR COMPLETE WORK SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH DRAWINGS AND SPECIFICATIONS. QUANTITIES LISTED IN ANY INSTANCE ARE FOR THE CON- TRACTOR'S CONVENIENCE ONLY AND ARE NOT GUARANTEED. ITEMS NOT SPECIFICALLY MENTIONED BUT NECESSARY TO COMPLETE THE WORK FURNISHED, MATCHING IN QUALITY AND FINISHED, THE ITEMS SPECIFIED. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER OPERATION AND FITTING OF HARDWARE IN LOCATIONS SPECIFIED. THE CONTRACTOR MUST SUPPLY A ROOM UNDER LOCK AND KEY TO STORE ALL FINISH HARDWARE UNTIL INSTALLATION IS MADE. THE HARDWARE SUPPLIER MUST MARK EACH ITEM OF HARDWARE AS TO DESCRIPTION AND LOCATION OF INSTALLATION IN ACCORDANCE WITH APPROVED HARDWARE SCHEDULE. EXPOSED SURFACES OF HARDWARE SHALL BE COVERED AND WELL PROTECTED DURING INSTALLATION, SO AS TO AVOID DAMAGE TO FINISHES. 3. PROVIDE HARDWARE FOR FIRE -RATED OPENINGS IN COMPLIANCE WITH REQUIREMENTS OF NFPA 80. THIS REQUIREMENT TAKES PRECEDENCE OVER OTHER REQUIREMENTS FOR SUCH HARDWARE. 4. HARDWARE FINISH SHALL BE SATIN CHROME, U.N.O. 5. HARDWARE SUPPLIER WILL PROVIDE APPROVED SCHEDULED AND PAPER TEMPLATES TO VARIOUS OTHER SUPPLIERS FOR DOOR AND FRAME PREPARATION FOR HARDWARE. 6. FURNISH AND FINISH HARDWARE, CYLINDERS AND KEYS: "BEST" SEVEN PIN ROD. 7. EACH ITEM OF HARDWARE SHALL BE PACKAGED SEPARATELY WITH ALL NECESSARY SCREWS, BOLTS, TAMPINS, KEYS AND INSTALLATION TEMPLATES. DELIVER PACKAGES, CLEARLY IDENTIFIED, WITH HEADING NUMBER AS APPROVED ON HARDWARE SCHEDULE. 8. INSTALL EACH HARDWARE ITEM IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS AND LOCATE IN ACCORDANCE WITH Dhl RECOMMENDED LOCATIONS. SET ITEMS LEVEL, PLUMB AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT SUB- STRATE, AS NECESSARY, FOR A SECURE INSTALLATION. SPACE FASTENERS AND ANCHORAGE AS INDI- CATED OR IN ACCORDANCE WITH INDUSTRY STANDARDS. 9. MAKE FINAL ADJUSTMENT AND CHECK OF HARDWARE DURING THE WEEK IMMEDIATELY PRIOR TO ACCEPTANCE. CLEAN AND RELUBRICATE OPERATING ITEMS AS NECESSARY, TO RESTORE PROPER FUNCTIONING AND FINISH OF HARDWARE AND DOORS. MAKE FINAL ADJUSTMENT OF LOCKSETS AND THE CLOSURES TO COMPENSATE FOR OPERATION OF HEATING AND VENTILATION SYSTEMS UNDER THE SUPERVISION OF MANUFACTURER'S REPRESENTATIVE. 10. LUBRICATE ALL MOVING PARTS WITH GRAPHITE -TYPE LUBRICANT, UNLESS OTHERWISE RECOMMENDED BY MANUFACTURER. REPLACE ALL HARDWARE WHICH CANNOT BE LUBRICATED AND ADJUSTED TO OPERATE FREELY AND SMOOTHLY. ttil Mph 2 v los • on OFIIIIVAILA MAY - S 2003 PERMIT CENTER "DC) ac 2 a 735 OPYIIIGlLNQI1 L ThsN drowings and specifications on copyrighted and subj M eopyrlght protection o s "orehNse "rig " under sc1 sec. 102 of the Cop��rrrighs oc t, s 7 u.S.C. As amended dseembsr I f/g0. the protection includes. wI*out IIn eoion. the ovMOII form, orrongsment and composition of spaces. and elements of the design. Under h proles /ion, unauthorised use of those drawings suc and spoeiftcallons may rssuI$ in Csssotion o const►uctlon, building seizure, and /or monofory liabilit -C V 4- 16 41- 0 • AOEIC7 2 of I+ P1 'SHERWIN WILLIAMS' #1017 "GARBO SILVER" (THIS IS A WHITE COLOR) 1. 2. 3. DOORS MUST BE OF HEAVY CONSTRUCTION, HUNG IN A FRAME SUFFICIENTLY STRONG TO AVOID PRYING. HINGES MUST BE EITHER LOCATED WITHIN THE DOORWAY OR THE SCREWS AND BOLTS MUST BE SET IN SUCH A WAY THAT THEY CANNOT BE REMOVED. HINGE PIN SHOULD BE WELDED, FLANGES OR WITH SET SCREWS TO PREVENT REMOVAL. DOOR JAMBS MUST BE OF A STRONG CONSTRUCTION TO PREVENT SPREADING BY A CROWBAR OR AUTOMOBILE JACKS. THE LOCKING BOLT MUST BE AT LEAST ONE (1) INCH INTO THE JAMB FOR PWIREVENTION TH A 7 -PIN OF CYLINDER SPREADINGGU. CYLINDERS ARD. SHOULD BE FLUSH OR INSET TO PREVENT "WRENCHING" ALL MEANS OF INGRESS OF SIXTY (60) SQUARE INCHES OR LARGER MUST BE SCREENED, LOCKED OR GRILLED IN SOME MANNER TO INCLUDE AIR VENTS, MANHOLES, LOADING CHUTES AND ALL OTHER AVENUES THROUGH THE ROOF AND OUTER WALLS. 4. NEVER KEY A JOB WITH PERMANENT KEYING DURING CONSTRUCTION PHASES. LOCKS SHOULD BE PROVIDED WITH CONSTRUCTION CORES AND RE -KEYED BY CORPORATE LOSS PREVENTION OR THE ASSIGNED DISTRICT MANAGER UPON THE COMPLETION OF THE JOB. 5. PERIMETER EMERGENCY EXIT MUST BE PROVIDED. WELDED PLATES AND /OR ONE (1) PIECE CON - STUCTION TO PROTECT FOREIGN OBJECTS FROM INSERTION (ie. WIRE LOOPS TO PANIC BAR HANDLES AND /OR SAWING OF THROW BOLTS.). 0. USE "BEST" LOCKING HARDWARE WITH INTERCHANGEABLE CORES. (BY PACIFIC SUNWEAR). b. MASTER KEY SYSTEM /CONTROLLED FROM CORPORATE LOSS PREVENTION. c. ALL CUSTOMER DOORS (PROVIDE IE CYLINDERS, FLUSH OR TAPERED HEAD) WITH A CYLINDER HEIGHT OF' 48 INCHES. d. IE 7 4 - - C- 181 -R -3 (626 FINISH OR THE DESIRED FINISH). ADAMS RITE LOCKS. (OR EQUAL) e. THUMBSCREW (INSIDE GATES) WITH TUBE PROTECTORS. f. EMERGENCY /SERVICE EXIT USE 70 -R ALARM (EXIT DEVICE) WITH "BEST" 1E72 RIM CYLINDER. (BY PACIFIC SUNWEAR). g. INSIDE CYLINDER ONLY. h. MANAGER OFFICE KEYED 83K7AB94 626- FINISH. i. STOCKROOM. TOILET, SERVICE AND OFFICE DOORS SHALL BE EQUIPPED WITH AUTOMATIC CLOSERS. (HYDRAULIC TYPE). • - _____s 1. PROVIDE CHANNEL- SHAPED ROLL FORMED SHEET STEEL MEMBERS CONFORMING WITH ASTM C640, HOT DIPPED FINISH WHERE EXPOSED TO MOISTURE NOT LESS THAN 20 GAUGE. PROVIDE 16 GAUGE AT DOOR JAMBS. 2. PROVIDE COLD. ROLLED STEEL CHANNELS NOT LESS THAN 16 GAUGE. 3. PROVIDE ROLL HAT - SHAPED CHANNELS MINIMUM 20 GAUGE, 7/8" DEEP WITH 1/2" HEMMED EDGES. HOT DIPPED FINISH WHERE NOTED. 4. PROVIDE TIE WIRES OF GALVANIZED ANNEALED WIRES NOT LESS THAN 16 GAUGE. 5. PROVIDE GALVANIZED HANGERS OF STEEL WIRE IN ACCORDANCE WITH ASTM C754. 6. PROVIDE JACK STUDS BETWEEN BOTTOM TRACK AND WINDOW AND /OR RELIEF SILLS BETWEEN LINTELS AND HEADERS IN TOP TRACKS. 7. PROVIDE BLOCKING AND FRAMING FOR ALL WALL MOUNTED FINISH HARDWARE AND EQUIP- MENT, INCLUDING DOOR STOPS. 8. PROVIDE CEILING SEISMIC BRACING IN ACCORDANCE WITH REQUIREMENTS OF APPLICABLE CODES AND AS INDICATED ON DRAWINGS. 9. PROVIDE DOUBLE BEAD TO BUTYL SEALANT AT FLOOR TRACKS. APPLY DOUBLE BEAD TO CEILING TRACT. AND TO STUDS ABUTTING OTHER CONSTRUCTION. 10. PROVIDE CHANNEL SHAPED BLOCKING SUPPORT OR GALVANIZED STRIP SUPPORT OF WALL -HUNG CABINETS. EQUIPMENT, FIXTURES AND ACCESSORIES OF NOT LESS THAN 22 GA. MATERIAL. PRO- VIDE SUPPORT IN WALL OR PARTITION FRAMING SYSTEM WHEREVER WALL HUNG CABINETS AND EQUIPMENT ARE INDICATED ON DRAWINGS. AND WHERE REQUIRED FOR MOUNTING OF MISCEL- ANEOUS ITEMS REQUIRING BACKING. 11. SET FLOOR TRACKS IN ACCURATE LOCATIONS AND SECURELY ANCHOR IN ACCORDANCE WITH ASTM STANDARDS. ERECT STUDS ON 16" OR 24" (AS INDICATED) CENTERS AND SECURE TO TRACK. INSTALL HEAD TRACK IN ACCORDANCE WITH DETAILS. INSTALL BLOCKING, BRACING, AND ANCHOR STRIPS; LEAVE READY TO RECEIVE FINISH MATERIALS. 12. ERECT ALL COMPONENTS FOR CEILING AND SOFFIT FRAMING IN ACCURATE LOCATIONS AS INDICATED. TRUE TO LINE, LEVEL AND PLUMB, AND IN ACCORDANCE WITH APPLICABLE ASTM STANDARDS AS REFERENCED ABOVE, USING A LASER LEVEL. ADJUST SUPPORTS, SPANS OR OTHERWISE FOR INSTALLATION WITHIN SPECIFIED TOLERANCES. 13. PROVIDE KICK BRACING IN ACCORDANCE WITH INDUSTRY STANDARDS FOR WALL STUDS, CEIL- ING MEMBERS, DRAFT OR SMOKE STOPS AND CURTAIN WALLS. 1. PROVIDE PAINT FINISHES FOR BUILDING AND OTHER SURFACES AS SCHEDULED ON DRAWINGS OR AS SPECIFIED HEREINAFTER INCLUDING SEALING OF CONCRETE FLOOR AT CORRIDOR AND STOCKROOM. NO PAINT FINISH IS REQUIRED ON ITEMS HAVING COMPLETE FACTORY FINISH, EXCEPT AS MAY BE SPECIFIED HEREINAFTER; PUTTY AND /OR SEALANT AT ALUMINUM WIN- DOWS; NON- FERROUS METAL UNLESS SPECIFICALLY MENTIONED IN THE PAINTING SCHEDULE; STAINLESS STEEL; INTERIOR OR EXTERIOR OF EXISTING BUILDING, EXCEPT WHERE ALTERATIONS OCCUR OR WHERE SCHEDULED. PAINT GRILLES AND DIFFUSERS. NO PAINTING IS REQUIRED FOR INSULATING PIPING, EXCEPT WHERE EXPOSED IN FINISH, NON - MECHANICAL ROOM SPACES. 2. PROTECT WORK OF OTHER TRADES FROM DAMAGE AND DEFACEMENT CAUSED BY THIS WORK. REPAIR ANY DAMAGE CAUSED BY THE WORK OF THIS SECTION. REMOVE ELECTRICAL OUTLET AND SWITCH PLATES, MECHANICAL DIFFUSERS, GRILLES, ESCUTCHEONS, REGISTERS, SURFACE HARDWARE, FITTINGS, AND FASTENINGS PRIOR TO COMMENCING THE WORK. STORE, CLEAN, AND REPLACE UPON COMPLETION. 3. PAINT CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR IF ANY SURFACE TO BE PAINTED OR STAINED IS FOUND TO BE UNSUITABLE TO PRODUCE PROPER FINISH. APPLY NO FINISH MATERIAL UNTIL THE UNSUITABLE SURFACES HAVE BEEN MADE SATISFACTORY. 4. FINISH WORK SHALL BE UNIFORM, OF APPROVED COLOR, SMOOTH AND FREE FROM RUNS. MAKE ENDS OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN. WHERE HIGH GLOSS ENAMEL IS USED, LIGHTLY SAND UNDERCOAT TO OBTAIN A SMOOTH FINISH COAT. 5. PROVIDE ALL NEWLY PAINTED SURFACES WITH (1) COAT TINTED PRIMER AND (2) COATS FI- NAL COLOR COAT, UNLESS OTHERWISE RECOMMENDED BY MANUFACTURER'S SPECIFICATIONS. 6. DELIVER ALL PAINT TO JOBSITE IN UNOPENED CONTAINERS BEARING THE MANUFACTURER'S LABEL, AND SHOWING PAINT TYPE, SHEEN AND COLOR. 7. PAINT TYPES USED SHALL BE THOSE SPECIFICALLY RECOMMENDED BY THE MANUFACTURER FOR THE MATERIAL TO WHICH THEY WILL BE APPLIED. PAINTING CONTRACTOR SHALL FOL- LOW MANUFACTURER'S INSTRUCTIONS FOR PROPER APPLICATION OF THE PAINT. 8. ALL SURFACES TO BE PAINTED SHALL BE THOROUGHLY CLEANED, AND PREPARED FOR PAINTING PRIOR TO APPLICATION OF PAINT. PROVIDE VENTILATORS AS REQUIRED TO PREVENT BUILD -UP OF FUMES. 9. SANDPAPER ALL NEW WOOD TO SMOOTH AND EVEN SURFACE AND DUST OFF. AFTER PRIM- ING COAT HAS BEEN APPLIED, THOROUGHLY FILL ALL NAIL HOLES AND OTHER SURFACE IM- PERFECTIONS WITH PUTTY TINTED WITH PRIMER OR STAIN TO MATCH WOOD COLOR. SAND ALL WOODWORK BETWEEN COATS TO A SMOOTH SURFACE. 10. PRIME ALL SURFACES WHICH RECEIVE PAINT PRIOR TO APPLICATION OF FINAL FINISH, IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 11. BACK PRIME ALL EXTERIOR AND INTERIOR WOOD AND TRIM PRIOR TO INSTALLATION. THOR- OUGHLY CLEAN SURFACES AND APPLY NO FINISH UNLESS SURFACES ARE DRY AND READY FOR APPLICATION. SANDPAPER SURFACES OF TRIM SMOOTH AND WIPE CLEAN. AFTER STAIN COAT HAS BEEN APPLIED, FILL CRACKS AND HOLES WITH PLASTIC WOOD OR PUTTY, IF STAIN HAS BEEN USED, TINT CRACK FILLER TO MATCH; PRIME BACKS OF TRIM. PRIME BARE WOOD SCHEDULED TO RECEIVE PAINT FINISH; FINISH NAIL HOLES, CRACKS, AND OTHER IMPERFECT- IONS WITH PUTTY AND SAND SMOOTH, 12. AT COMPLETION, TOUCH -UP AND RESTORE FINISH WHERE DAMAGED AND LEAVE ALL SUR- FACES IN GOOD AND CLEAN CONDITION. PROVIDE FOR MULTIPLE SITE VISITS AS REQUIRED FOR TOUCH -UP AND REFINISHING. 13. OTHER PAINT MANUFACTURER'S MAY NOT BE SUBSTITUTED. 14. FINISH INTERIOR SURFACES, AS SCHEDULED ON DRAWINGS, EXCEPT AS MODIFIED AND SUP- PLEMENTED HEREINAFTER AND UPON WR ITTEN OWNER APPROVAL. IN GENERAL, USE EGGSHELL SHEEN FOR WALL BOARD SURFACES; SEMI -GLOSS FOR HOLLOW METAL AND WOOD TRIM; AND FLAT FOR DUCTWORK. 4 SPECIFICATIONS 1. INSTALL COVE BASE IN AREAS AS CALLED FOR IN PLANS & OR ELEVATIONS. 2. PROVIDE PREMOLDED INSIDE AND OUTSIDE CORNERS FOR ALL CONDITIONS AT WHICH CORNERS ARE TO BE USED. JOB MITERING SHALL BE PERMITTED ONLY UPON OWNER'S APPROVAL. 3. USE ADHESIVES ONLY AS RECOMMENDED BY THE MANUFACTURER OF THE MATERIAL TO WHICH IT IS APPLIED. 4. CAREFULLY INSPECT ALL SURFACES TO RECEIVE BASE PRIOR TO INSTALLATION. REPAIR DAMAGED SURFACES PRIOR TO INSTALLATION. 5. UPON COMPLETION, IMMEDIATELY REMOVE ALL SURPLUS ADHESIVE FROM ADJACENT SURFACE, IN ACCORDANCE WITH THE TIMING RECOMMENDED BY THE MANUFACTURER, USING MATERIALS RECOMMENDED FOR THAT PURPOSE BY THE MANUFACTURER. a.AU i d.Aa110 1. PROVIDE TEMPERED GLASS, GRADE "B ", STYLE #1, TYPE "1 ", QUALITY 03, '1/2" THICK. 2. ALL GLASS EDGES SHALL BE GROUND SMOOTH & POLISHED. 3. GENERAL GLASS SHALL BE q3 IN ACCORDANCE WITH FEDERAL SPECIFICATIONS DD -G -451 AND FGMA GLAZING MANUAL. 4. STOREFRONT GLASS SHALL BE AS REQUIRED FOR THE SIZES AND CONDITIONS DETAILED. FRAME SECTION SHALL BE CONCEALED WHERE INDICATED. 5. PROVIDE RESILIENT NEOPRENE BLOCKS 70 TO 90 SHORE A DUROMETER HARDNESS AND RESILIENT ACCESSORIES DESIGNED FOR POSITIONING GLASS IN RABBETS. 6. PROVIDE CLIPS OF NON - CORROSIVE METAL WITH ROUNDED EDGES DESIGNED FOR CONTACT BLOCKS, NOT GLASS. 7. PROVIDE STANDARD PREFORMED GLAZING TAPE, STANLOCKE 400, TRIMCO 440, OR APPROVED. 8. PROVIDE NON- SHRINKING ELASTOMERIC TAPE WHERE REQUIRED. 9. USE SILICONE SEALANT DOW #795 OR GE SILPRUF, COLOR AS SPECIFIED, OR APPROVED EQUAL. 10. ALL EDGES, DRILLED HOLES AND NOTCHES SHALL BE FACTORY CUT AND /OR FACTORY FORMED. TOUCH -UP "RAW" EDGES TO MATCH FRAME. 11. INSTALL IN ACCORDANCE WITH FGMA RECOMMENDATIONS UNLESS NOTED OTHERWISE. 12. VERIFY THAT FRAMES TO RECEIVE GLAZING ARE SQUARE AND TRUE, THAT PERIMETER CLEAR- ANCES ARE SUFFICIENT TO PREVENT "POINT LOADING ", AND THAT SURFACES ARE CLEAN, DRY AND READY TO RECEIVE GLAZING MATERIALS. REMOVE ALL PROTECTIVE COATINGS FROM FRAMING SURFACES. 13. CENTER GLASS IN RABBETS AND POSITION SO AS TO MAINTAIN CLEARANCES ON ALL SIDES, INDOORS AND OUT. IN ACCORDANCE WITH FGMA RECOMMENDATIONS. SHIM AS REQUIRED TO POSITION AGAINST FIXED STOPS AND FRAME BARS. 14. SET ALL EXTRUSIONS IN CORRECT LOCATIONS AS SHOWN IN THE DETAILS. THEY SHALL BE LEVEL, FLUSH, SQUARE, PLUMB AND IN ALIGNMENT WITH OTHER WORK. 15. UPON COMPLETION, REMOVE ALL EXCESS SEALANT AND MATERIALS FROM SURFACES; WASH AND CLEAN ALL GLASS FRAMING MEMBERS. SUSPENDED ACOUSTICAL CH.Nf3 . SYSTEM COMPONENTS SHALL CONFORM TO ASTM C635 INTERMEDIATE DUTY AND UBC STANDARD 47 -18 INTERMEDIATE DUTY. INSTALLATION OF SYSTEMS SHALL CONFORM TO ASTM C636, WITH A DEFLECTION OF NOT MORE THAN 1/360 OF THE SPAN. FURNISH AND INSTALL ALL LABOR AND MATERIALS FOR COMPLETE ACOUSTICAL CEILING. REVIEW JOB SCHEDULE TO VERIFY INSTALLATION DATES AND MATERIAL AVAILABILITY. 2. COORDINATE ACOUSTICAL SUSPENSION SYSTEM WORK WITH OTHER WORK, SUCH AS CEILING LIGHT FIXTURES AND AIR OUTLETS. PROTECT FINISHED WORK INSTALLED BEFORE INSTALLATION OF ACOUSTICAL SUSPENSION SYSTEM. REPLACE WORK DAMAGED BY WORK UNDER THIS SECTION. THE TENANT'S G.C. SHALL MAINTAIN FIRE AND SMOKE RATINGS AS REQUIRED BY CODES AND LANDLORD'S SPECIFICATIONS AND REGULATIONS. 3. ALL LOCKING CROSS TEES SUPPORTING OTHER CROSS TEES SHALL CONFORM TO THE SAME CLASSIFICATION AS THE MAIN RUNNERS. MAIN RUNNERS AND CROSS TEES SHALL BE COLD ROLLED ELECTRO - GALVANIZED STEEL. WALL ANGLE MOLDINGS SHALL BE COLD ROLLED ELECTRO- GALVANIZED STEEL. CORNERS SHALL BE MANUFACTURER'S PREFABRICATED INSIDE AND OUTSIDE CORNER MOLDINGS. 4. FINISH SHALL BE BAKED ENAMEL IN SELECTED COLOR. 5. HANGER WIRE SHALL BE 12 GAUGE GALVANIZED STEEL WIRE CONFORMING TO FS QQ -W -461, TYPE I. 6. INSPECT LOCATIONS TO RECEIVE WORK AND CHECK THE EXISTING DIMENSIONS. ASCERTAIN BEFORE PROCEEDING WITH WORK THAT ALL REQUIRED INSPECTIONS HAVE BEEN MADE. COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF RESPONSIBILITY RELATED TO GUARANTEE REQUIREMENTS. THE BUILDING SHALL BE EXAMINED BEFORE BEGINNING WORK TO DETERMINE THAT IT IS PRO- PERLY ENCLOSED AND THE STRUCTURE IS IN PROPER CONDITION TO RECEIVE ACOUSTICAL MA- TERIALS. THE AREA SHALL BE BROOM CLEANED AND UNINTERRUPTED FOR FREE MOVEMENT OF SCAFFOLD- ING. SCAFFOLDING SHALL BE OF A TYPE THAT WILL NOT SCAR OR MAR FLOOR SURFACES AND WILL NOT DAMAGE OTHER CONSTRUCTION. WORK NOT TO PROCEED UNTIL SATISFACTORY CON- DITIONS DESCRIBED ABOVE PRESIDE. 7. ATTACH HANGER WIRE TO SOUND, SECURE STRUCTURAL MEMBERS CAPABLE OF CARRYING THE NEW LOAD WITHOUT DEFLECTION. WRAP, BOLT OR CLIP WIRE HANGERS TO STRUCTURAL STEEL MEMBERS, OR INSTALL DROP CLIPS ON STRUCTURAL STEEL MEMBERS AND TIE WIRE HANGERS TO DROP CLIPS. INSTALL SUPPLEMENTARY FRAMING,BLOCKING AND BRACING WHERE NECESSARY TO SUSPEND CEILING SYSTEM FIXTURES AND EQUIPMENT AND WHERE SPACING OF STRUCTURAL SUPPORTS EXCEEDS SPECIFIED HANGER SPACING. WHERE DIRECT SUSPENSION OF SUPPLEMENTARY FRAMING FOR SUPPORT OF EQUIPMENT, FIXTURE OR DUCTWORK IS NOT POSSIBLE DUE TO OBSTRUCTIONS, SUPPLEMENTARY FRAMING MAY BE SUSPENDED BY "TRAPEZE" ARRANGEMENT OF HANGER WIRE. SUSPEND LIGHT FIXTURES FROM STRUCTURE BY ATTACHMENT OF ONE HANGER AT EACH CORNER OF THE FIXTURE. FURNISH ADDITIONAL WIRES FOR LIGHTING FIXTURES AND MECHANICAL REGISTERS IN SUSPENDED CEILING. PROVIDE SEISMIC BRACING AS REQUIRED. 8. INSTALL CEILING SUSPENSION SYSTEM IN ACCORDANCE WITH ASTM C636. LOADING OF ANY COMPONENT MAY NOT CAUSE DEFLECTION OF MORE THAN 1/360 OF THE SPAN. USE LASER LIGHT FOR LAYOUT AND LEVELING. INSTALL MAIN RUNNERS 48 INCHES Q.C. TIE HANGER WIRES TO MAIN RUNNERS TIGHTLY WITH AT LEAST THREE FULL TURNS. INTERCONNECT MAIN RUNNERS BY LOCKING CROSS TEES 48 INCHES LONG TO FORM 24 INCH BY 48 INCH MODULES. WHEREVER SHOWN ON THE DESIGN PLANS, THESE MODULES SHALL BE DIVIDED BY CROSS TEES 24 INCHES LONG INSTALL PER- PENDICULAR TO THE OTHER CROSS TEES TO FORM 24 INCH BY 24 INCH SECTIONS. PROPER LENGTH LOCKING CROSS TEES SHALL ALSO BE INSTALLED ADJACENT TO ALL SIDES OF RECESSED LIGHT FIXTURES NOT SUPPORTED BY A MAIN RUNNER. 9. ALL SUSPENDED CEILINGS SHALL BE BRACED TO RESIST LATERAL AND HORIZONTAL MOVEMENT AS REQUIRED BY THE GOVERNING CODES. THE TENANT'S G.C. SHALL VERIFY ALL APPLICABLE CODES AND CONFORM. '10. CUT TILES TO MATCH FIELD PATTERN RECESS. ANY ACOUSTICAL CEILING PANELS LESS THAN FULL SIZE SHALL HAVE CUT EDGES TRIMMED TO MATCH FACTORY TEGULAR EDGES. SUSPENDED CEILING SHALL HAVE INTERSECT ALL VERTICAL WALLS AT 90 UNLESS OTHERWISE NOTED. 11. UPON COMPLETION OF WORK FOLLOWING INSTALLATION OF SUSPENSION SYSTEMS, DIRTY OR DISCOLORED SURFACES OF SUSPENSION COMPONENTS SHALL BE CLEANED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND LEFT FREE FROM DEFECTS. COMPONENTS THAT ARE DAMAGED OR IMPROPERLY INSTALLED BE REMOVED AND REPLACED WITHOUT ADDITIONAL COST TO THE OWNER. 12. LEAVE FOUR, FULL, UNDAMAGED TILES AT JOBSITE. 161121-111-7-11EMILEla 2. DISTALLATIOtt 1. DELIVER INSERTS AND ROUGH -IN FRAMES TO JOBSITE AT APPROPRIATE TIME FOR BUILDING IN. 2. FASTENINGS: FURNISH TOILET ACCESSORIES TO COMPLETE WITH ALL REQUIRED MOUNTING DEVICES, FASTENINGS, AND ACCESSORIES AS REQUIRED FOR A FINISHED INSTALLATION, PRO- PERLY PACKAGED AND TAGGED FOR READY IDENTIFICATION. FASTEN ALL ITEMS WITH SCREWS OR BOLTS EXTENDING AT LEAST 1" INTO SOLID BACKING IF NO OTHER FASTENING IS SPEC- IFIED 3. INSTALLATION OF TOILET ACCESSORIES SHALL BE IN ACCORDANCE WITH THE DRAWINGS, RE- VIEWED SHOP DRAWINGS, AND THE MANUFACTURER'S INSTALLATIONS AND RECOMMENDATIONS. 4. TEN. G.C. SHALL SUPPLY & INSTALL ADEQUATE BACKING FOR SECURE INSTALLATION OF ALL ACCESSORIES. MOUNT• t 1. LOCATIONS AND HEIGHTS, SHALL BE AS SHOWN ON DRAWINGS AND IN CONFORMANCE WITH 'HANDICAP' ORDINANCES. SKIM . SIGNS ARE SUPPLIED & INSTALLED BY OWNERS SIGN CONTRACTOR. G.C. SHALL PROVIDE POWER SOURCE & REQUIRED DISCONNECTS, TIME CLOCKS ETC.. COORDINATE WITH SIGN CONTRACTOR AS REQUIRED. 1. EXTINGUISHERS SHALL BE 10 -POUND CAPACITY, U.L. LABELS, ENAMEL, STEEL CONTAINER WITH PRESSURE INDICATING GAUGE FOR CLASS A, B. OR C FIRES. 2. INSTALL ON WALL MOUNTED HOOKS AS INDICATED OR DIRECTED BY THE MARSHALL, NEATLY FITTING TO FINISH SURFACES. PLACE FULLY CHARGED EXTINGUISHERS ON HOOKS PRIOR TO OCCUPANCY. 3. SEE FIXTURE PLAN FOR ARCHITECTS SUGGESTED LOCATIONS. SENSORMATIC: 1. PROVIDE (1) 115V, 3 -WIRE, 24 HOUR CIRCUIT WITH (1) DUPLEX RECEPTACLE, FOR SYSTEM POWER -IN SOFFIT AREA STOREFRONT. 2. TRADES SHALL COORDINATE WITH SENSORMATIC INSTALLER THROUGH ALL PHASES OF CON- STRUCTION FOR INTEGRAL SYSTEM INSTALLATION. NOTES: 1. 2. 3. TENANT'S C.C. SHALL PROVIDE ADEQUATE BACKING FOR SECURE INSTALLATION OF ACCESSORIES. ALL ACCESSORIES SHALL BE INSTALLED IN ACCORDANCE WITH ALL GOVERNING NATIONAL, STATE AND LOCAL CODES PERTAINING TO HANDICAP ACCESSIBILITY. ACCESSORIES: SP -1 SP- 2 SP- 3 SP- 4 SP-5 SP -6 ▪ TI T SYSTEM AUDIO/VIDEO TOILET PAPER HOLDER: AS SELECTED BY TENANT G.C. AND APPROVED BY OWNER. NOT USED MIRROR: AS SELECTED BY TENANT G.C. AND APPROVED BY OWNER. GRAB BARS: AS SELECTED BY TENANT G.C. AND APPROVED BY OWNER. PAPER TOWEL DISPENSER: AS SUPPLIED BY PACIFIC SUNWEAR, INSTALLED BY G.C. TRASH CONTAINER: "RUBBERMAID" 2952, 8 1/2 QT. BEIGE VINYL CONTAINER. (BY OWNER) w a ocimaisas asvom sr nGl SENSORMATIC ELECTRONICS CORPORATION 3960 VIA ORO AVENUE, SUITE 110 LONG BEACH, CALIFORNIA 90180 1 (800) 241 -6678 CONTACT: BRIAN LINSKEY ALL AUDIO AND VIDEO CABLES SHALL BE RUN IN EMT. (UNLESS OTHERWISE NOTED) LEAVE ADEQUATE AMOUNT OF SLACK IN AUDIO AND VIDEO CABLES FOR PROPER POSITIONING EQUIPMENT AFTER INSTALLATION. EXCESS LENGTHS OF CABLE SHALL BE CONCEALED IN BRACKETS OR CEILING. EQUIPMENT: 1. AS PROVIDED BY 'BOSE' CORP AND DMX. NOTE: ITEM 1 IN THIS SECTION ARE FURNISHED BY "BOSE CORP." AND DMX (G.C. TO SUPPLY EMT WI PULL STRING. (UNLESS OTHERWISE NOTED) GYPSUM WALL BOARD 1. PROVIDE GYPSUM WALL PANELS MANUFACTURED IN ACCORDANCE WITH REQUIREMENTS OF ASTM 336. 2. PROVIDE TYPE 'X' FIRE RETARDANT GYPSUM WALL BOARD PANELS 5/8" THICK, TESTED & QUALIFIED FOR 1 -HOUR RATING, TAPERED AND ROUNDED AT EDGES AS INDICATED ON DRAWINGS. 3. PROVIDE METAL EDGE AND CORNER BEADS AT ENDS, EDGES AND CORNERS. 4. WATER RESISTANT GYPSUM WALL BOARD SHALL BE 5/8" THICK, QUALIFIED FOR 1 -HOUR RATING, TAPERED AND ROUNDED EDGES AND SHALL BE INSTALLED IN ALL WET AREAS AS INDICATED ON DRAWINGS. 5. PROVIDE FASTENERS IN ACCORDANCE W/ ASTM C646; UNLESS OTHERWISE NOTED OR INDICATED, PROVIDE TYPE 'S' BUGLE HEAD SCREWS FOR ATTACHMENT OF WALL BOARD TO METAL FRAMING, AND TYPE 'S' PAN HEAD SCREWS FOR ATTACHMENT OF FRAMING TO DOOR FRAMES. 6. PROVIDE ALL INCIDENTAL & ACCESSORY MATERIALS, TOOLS, EQUIPMENT, AND METHODS REQ'D FOR SATISFACTORY COMPLETION OF GYPSUM WALL BOARD CONSTRUCTION INCLUDING ACCESS DOORS AND PANELS. 7. APPLY CONTINUOUS BEAD SEALANT AT ALL JOINTS OF WALL BOARD ABUTTING ADJACENT CONSTRUCTION, INCLUDING AROUND FRAMED OPENINGS AND OTHER PROTRUSIONS THROUGH WALL BOARD WHERE SEALANT IS EXPOSED. PROVIDE POLY- SULFIDE SEALANT; WHERE UNEXPOSED. PROVIDE ACOUSTIC SEALANT. 8. APPLY PRE -FILL COMPOUND TO JOINTS IN ACCORDANCE WITH INDUSTRY STANDARDS. APPLY EMBEDDING COMPOUND REINFORCING TAPE CENTERED OVER JOINT; APPLY SKIM COAT. AFTER TAPING & EMBEDDING COMPOUND IS DRY, APPLY SECOND COAT FILLING & TAPER FLUSH W/ SURFACE; FIRE TAPE PENETRATIONS AT DEMISING WALLS, CORRIDOR ENVELOPE & OTHER RATED ASSEMBLIES. 9, PROVIDE FINAL FINISH THAT IS SMOOTH, WITHOUT DIVOTS, BUMPS, BOWS OR ANY OTHER SURFACE BLEMISH, READY TO RECEIVE PAINT. 10. CUSTOM SKIP TROWELED FINISH WHERE SPECIFIED ON PLANS. COORDINATE FINISH WITH ARCHITECT. t* • A OF PANT PAINT NOTE* WALLCOVERIIG, METAL FNSHES SPECIALTY GLAZING FLOORING F-1 F-3 BASE MATERIALS B-2 NOT USED FINISH SCHEDULE PANT NNW PAINT SHEENS ON SURFACES TO BE AS FOLLOWS: • SALES AREA WALLS AND CEILING - EGGSHELL • ALL DOORS AND FRAMES (EXCEPT FITTING ROOM) - SEMI GLOSS • STOCK RM., HALLWAY, OFFICES AND OTHER NON SALES AREA WALLS - SEMI GLOSS • INSIDE TOILET ROOM WALLS, CEILING DOOR AND FRAME - GLOSS 1. ALL GYP. BD. SURFACES THROUGHOUT SHALL HAVE A SMOOTH (NO TEXTURE) SANDED SURFACE AND SHALL BE PREPARED FOR PAINT FINISH AS SPECIFIED ON THE PLANS. 2. ALL PAINT USED SHALL BE COMMERCIAL WATER BASED INTERIOR ENAMEL 3. ALL NEW GYP. BD. SURFACES SHALL RECIEVE 3 (THREE) COATS OF PAINT. 4. ALL GYP. BD SURFACES TO RECIEVE WALLCOVERING OR OTHER APPLIED FINISHES SUCH AS WALLCOVERING, SLATWALL OR WALL PANELS SHALL RECIEVE A SMOOTH SANDED FINISH AND PRIMER TO MATCH ADJACENT FINISHES BEFORE FINAL MATERIAL IS APPLIED UNLESS OTHERWISE NOTED. MA LANARK VINYL WALL COVERING - LA CROIX TYPE II # L2 -LC -05 - SHADOW 16GA. BLACK ANODIZED ALUMINUM BREAK METAL NOTE: ANY OTHER METALS DESIGNATED AS MF -1 SHALL MATCH THIS FINISH NIF-2 YELLOW 'CHEM -- METAL' TO MATCH YELLOW MOZ METAL MOUNTED ON 1/4" MASONITE PANELS. PANELS ARE ADHERED DIRECTLY TO WALL SURFACE WITH COMMERCIAL CONSTRUCTION ADHESIVE. FLOOR TO CEILING. 9/4„:1 CUSTOM LAMINATED GLASS: 2 LAYERS OF 1/8" ANNEALED SAFETY GLASS W/ #3088 YELLOW RICE PAPER. IN SIZES AS INDICATED ON THE DRAWINGS. ALL GALSS TO COMPLY WITH ASTM C 1172 SAFETY STANDARDS FOR LAMINATED GLASS PRODUCED WITH A FORMULATED INNER LAYER AND SUBSTRATE TO LAMINATE UNDER HEAT AND PRESSURE BETWEEN 2 PIECES OF ANNEALED GLASS. SOURCE: PULP STUDIO LOS ANGELES CA USA 310 815 -4999 F-1 'WEAR -GUARD SELF LEVELING COLORED WEAR TOPPING. COLOR: PACSUN DARK GRAY #2 SEALER: WEAR GUARD 500 OWNERS CONTACT: PECKHAM INDUSTRIAL COATINGS 1085 -C COLE AVENUE CLOVIS, CA 93612 DANNY PECKHAM (559) 298 -4173 FAX (559) 299 -4016 www.peckhamcoatings.com 12' X 12" X 1/8" VCT. 'ARMSTRONG, STANDARD EXCELON' # 51836 SHELTER WHITE INSTALL WITH MFGRS. RECOMMENDED ADHESIVE. F-4 WHITE OR LIGHT COLOR, RESILIENT SHEET VINYL FLR'G W/ 6" HIGH CONTINUOUS COVE BASE & ALUM. CAP. INSTALL W/ MFGRS. RECOMMENDED ADHESIVE. NO SEAMS F-6 12' X 12" X 1/8" VCT. 'ARMSTRONG, STANDARD EXCELON' # 51816 CHERRY RED. INSTALL WITH MFGRS. RECOMMENDED ADHESIVE. (USED AT EXIT PATH THROUGH STOCK RM.) 'ROPPE' #00 BLACK 6" HIGH RUBBER BASE, INSTALL WITH MFGRS. RECOMMENDED (APPLY IN SALES AREA). 'ROPPE' #00 BLACK 4" HIGH RUBBER BASE, INSTALL WITH MFGRS. RECOMMENDED ADHESIVE. (APPLY IN STOCKROOM). 6" HIGH COVED SHEET VINYL BASE W/ ALUM TRIM CAP. SEE F -3 (IN TOILET ROOM) '1D C53 -1 3q tOwlPg 1 1%16 v oo • ABICINVID CRY OF TUKWILA S 'LTV PE I' MITA 735 !COPYRIGHT Aca ; Thole drowIngs and specifications are copyrighted and subject to copyright protection as on "orchfecturel work Under sec. 102 of the copyright Get, I7 u.S.C. As amended docember I900. The protection includes, without limitation, the ovoroil form, arrangement end composition of spaces. and eIomenis of t$ . design_ Under such protection, unauthorised use of these drawings and specifications may result in cessofoA 0 4 construction, building seizure. and /or monetary Nobility • Saki: O11ANM1 It 1 NO.: QATE: OS ..07 -o SI•ET: �g 1 72 mit P � 4 . 40,1 Mil SP2 0 B of IN • I , RESPONSIBILITY SCHEDULE ITEM . PIArI sr_ SNTALLID ONT. , IIIMAISES 0090 _ _ 1 ( _ FLOOR FIXTURES V I _ .. ILECTRICAL mown LIGHT FIXTURE SUPPORTS (UNISTRUT/ THREAD/ _ WALL STANDARDS • . 6 - TEMP. LIGHTING/ POWER 6" HIGH, BLACK ANODIZED (NAT. MALLFRNI TRANSOM GLAZING i WALL MIRRORS • • . FINAL CONNECTION OF POWER TO SIGNS (NAT. MALLFRNT.) GLAZING CHANNELS i • FLOOR MIRRORS - 4 i ( " TIMECLOCKS FOR SIGN(S) ROLL -UP GRILLE • MERCHANDISING HDW. • G G.0 TO COORD. W/ OWNERS INSTALLER I TOILET ROOM 4 EXHAUST FAN METAL SLATWALL PANELS " FIRE ALARM SYSTEM , SHOE BENCH (1) • WHEN REQUIRED - VERIFY WITH MALL : . COLORED WD. WALL PNLS. • WALLCOVERING • S.R. DOOR KICK PLATE • : MISCELLANEOUS P PAY PERMIT FEES PERMIT/ _ • • CONSTRUCTION SITE PHONE AND FAX • • • ARCH ACT FORMATION TO PACSUN AND SPRINKLER SYS. PLANS/ PLANS PERMIT/ FEES _ • 0 MALL EPOSIT INSURANCE WAIVERS 0 VERIFY MALL'S REQUIRED CONTRACTOR L CLEANING LINATORIAL SERVICE/ . 0 . TRASH REMOVAL/ DUMPSER RENTAL 0 " ROOF PENETRATIONS DEMOLITION/ PERMIT AND FEE'S AS REQUIRED TEMPORARY BARRICADE :. • COORDINATE WITH LANDLORD AND MALL. RECEIVE / UNLOAD ALL TENANT SUPPLIED ITEMS , SPECIALTY ANTI THEFT SYSTEM SCANNERS, TAG GUNS • • • • G.C. TO COORDINATE WITH INSTALLER COMPUTER / POS SYSTEM • • BUZZER SYSTEMS • • SEE ELECTRICAL DRAWINGS. FIRE EXTINGUISHERS • VERIFY LOCATIONS W/ FIRE MARSHALL FIRE ALARM SYSTEM • WHEN REQUIRED - VERIFY WITH MALL CASH / BACK WRAP _ • lo to.* 0090 _ _ 1 ( _ FLOOR FIXTURES 090I0* I ICI _ . ( `• _ WALL STANDARDS . 6 6" HIGH, BLACK ANODIZED (NAT. MALLFRNI TRANSOM GLAZING i WALL MIRRORS • (NAT. MALLFRNT.) GLAZING CHANNELS i FLOOR MIRRORS - 4 i ( (NAT. MALLFRNT.) ROLL -UP GRILLE • MERCHANDISING HDW. • G G.0 TO COORD. W/ OWNERS INSTALLER METAL SLATWALL PANELS , SHOE BENCH (1) : . COLORED WD. WALL PNLS. • WALLCOVERING • S.R. DOOR KICK PLATE • : STOREFRONT TUBING 4 410 _ lo to.* 0090 _ _ 1 ( _ CLEAR WINDOW GLAZING 0 090I0* I ICI . ( (NAT. MALLFRNT.) ALUM. GLAZING BASE . . 6 6" HIGH, BLACK ANODIZED (NAT. MALLFRNI TRANSOM GLAZING i i ( (NAT. MALLFRNT.) GLAZING CHANNELS i 4 i ( (NAT. MALLFRNT.) ROLL -UP GRILLE • • G G.0 TO COORD. W/ OWNERS INSTALLER OFFICE DESK • FILE CABINET 0 SAFE • • G.C. TO BOLT TO FLOOR LOCKERS • , . , G.C. TO ASSEMBLE. • LIGHT FIXTURES • STANDARDS & BRACKETS ii 6 , SHELVING • • FIRE TREATED IF REQ'D. BULLETIN BOARDS • • VERIFY LOC. W/ PACSUN OPERATIONS PAINT AND PRIMER • 0 - CEILING SYSTEM • • ROLLING SHELVING UNITS 0 • FLOOR DEMO, SCRAPE • _ • FLR. PATCH, BEAD BLAST • • (PECKHAM) CONCRETE TOPPING (PECKHAM) TRANSITION STRIPS VCT FLOORING • • INCLUDING SETTING MATERIALS SHEET VINYL • • INCLUDING SETTING MATERIALS CONCRETE SEALER • • (PECKHAM) CONTRACTOR RUBBER BASE • • INCLUDING SETTING MATERIALS VINYL COVE BASE • • INCLUDING SETTING MATERIALS 1 , I HVAC UNIT / EQUIPMENT • • RTU I ROOF CURB • • SUPPLY AND R/A DUCTWORK PER PLAN e • ALL DIFFUSERS / GRILLES • 111) • THERMOSTATS • CLR. LOCKING COVER(S) • • TOILET RM. EXHAUST FAN • • AIR BALANCE REPORT BY • _ INDEPENDENT CONTRACTOR FIRE DAMPERS • AS REQUIRED SMOKE REMOVAL SYSTEM • AS REQUIRED MODIFY SPRINKLER SYS. • • GYP. BD. CEILINGS OR SOFFITS _ ACCOUSTICAL TILE & GRID FRAMING /GYP. BD./ PLYWOOD AT TOILET , FRAMING GYP. BD./ WHEN REQUIRED PLYWOOD AT HALLWAY , ni,11 QC 1°114 tl AV 2 7 1183 . r� lo to.* 0090 FLOOR DEMO, SCRAPE • _ • FLR. PATCH, BEAD BLAST • • (PECKHAM) CONCRETE TOPPING (PECKHAM) TRANSITION STRIPS VCT FLOORING • • INCLUDING SETTING MATERIALS SHEET VINYL • • INCLUDING SETTING MATERIALS CONCRETE SEALER • • (PECKHAM) CONTRACTOR RUBBER BASE • • INCLUDING SETTING MATERIALS VINYL COVE BASE • • INCLUDING SETTING MATERIALS 1 , I HVAC UNIT / EQUIPMENT • • RTU I ROOF CURB • • SUPPLY AND R/A DUCTWORK PER PLAN e • ALL DIFFUSERS / GRILLES • 111) • THERMOSTATS • CLR. LOCKING COVER(S) • • TOILET RM. EXHAUST FAN • • AIR BALANCE REPORT BY • _ INDEPENDENT CONTRACTOR FIRE DAMPERS • AS REQUIRED SMOKE REMOVAL SYSTEM • AS REQUIRED MODIFY SPRINKLER SYS. • • GYP. BD. CEILINGS OR SOFFITS _ ACCOUSTICAL TILE & GRID FRAMING /GYP. BD./ PLYWOOD AT TOILET , FRAMING GYP. BD./ WHEN REQUIRED PLYWOOD AT HALLWAY , ni,11 QC 1°114 tl AV 2 7 1183 . r� lo to.* 0090 I HVAC UNIT / EQUIPMENT • • RTU I ROOF CURB • • SUPPLY AND R/A DUCTWORK PER PLAN e • ALL DIFFUSERS / GRILLES • 111) • THERMOSTATS • CLR. LOCKING COVER(S) • • TOILET RM. EXHAUST FAN • • AIR BALANCE REPORT BY • _ INDEPENDENT CONTRACTOR FIRE DAMPERS • AS REQUIRED SMOKE REMOVAL SYSTEM • AS REQUIRED MODIFY SPRINKLER SYS. • • GYP. BD. CEILINGS OR SOFFITS _ ACCOUSTICAL TILE & GRID FRAMING /GYP. BD./ PLYWOOD AT TOILET , FRAMING GYP. BD./ WHEN REQUIRED PLYWOOD AT HALLWAY , ni,11 QC 1°114 tl AV 2 7 1183 . r� lo to.* 0090 GYP. BD. CEILINGS OR SOFFITS _ ACCOUSTICAL TILE & GRID FRAMING /GYP. BD./ PLYWOOD AT TOILET , FRAMING GYP. BD./ WHEN REQUIRED PLYWOOD AT HALLWAY , ni,11 QC 1°114 tl AV 2 7 1183 . r� lo to.* 0090 ROLL -UP GRILLE & HOWE. ■ METRO DOOR GLASS DOORS & FRAME ■ NOT USED ON THIS PROJECT DOOR FRAME HARDWARE • l r FRAMES • HARDWARE S [J IIL -11M 11•0' - FRAME HARDWARE Li 1 REAR DOOR AND FRAME ■ . REAR DOOR HARDWARE [] ADD NEW PANIC BAR PER PACSUN REQ. - A De•- NI INIIIIIMICJ 7 PI RIM Y I I R A "AN L A ' o • [IJ AS REQUIRED FOR M•TOR VAV ETC. ■ ■ ■ ■ LANDLORD DISTRIBUTION VERIFY AVAILABILITY FOR LOAD DEMAND PANEL _ ■ METER MAIN DISCONNECT ' AND FUSES _ , _ _ CONDUIT TO SPACE • G.C. TO UPSIZE IF REQ. VERIFY AT BID EXTEND CONDUIT WITHIN SPACE - I, WIRE TO SPACE G.C. TO EXTEND IF REQUIRED . L r A I r ■ . DISCONNECT WITHIN SPACE SEE ELECTRICAL FOR SCOPE PANEL L 0 -0 . , TRANSFORMER • RELOCATE . , PANEL H • RELOCATE HOMERUNS/ CONDUITS/ ' - ' tl CONTROLS: SWITCHES/ CONTACTORS CONTACTORS TEL. CONDUIT TO SPACE G.C. TO EXTEND AS REQ. VERIFY •N•UI Nr • • FOR P.O.S.! PHONE SYS. , HVAC SYSTEM RING AGE) (LINE AND LOW WI VOLT BUZZER SYSTEM i _ LIGHT FIXTURES J . T . KNOCK DOWN SYSTEM WHEN USED. SEE PLAN g _ 2v03 WALL - MOUNTED MIRRORS _ • HOOKS ON DOORS MAW COMER HOOKS ON WALLS TAG HOOKS - • • SEE DETAIL CAULKS/SILICONES/ 0 MA,STIQS /ADHESIVES - AS REQUIRED FIXED SEAT LEDGE • OWNER SIGNAGE # OF ITEMS, SHOPLIFTNG, ETC. ■ 4Il "M I 5 ? CODE RELATED SIGNAGE • AS REQUIRED le PLUMING / TOLET I EXTEND WASTE / VENT I LINES WITHIN SPACE EXTEND WATER LINES • ▪ WITHIN SPACE I LOCATE ACCESS WASTE STUB -UP WATER CLOSET & LAV. I MOP SINK. I DRINKING FOUNTAINS I FLOOR DRAIN / TRAP I PRIMER I WATER HEATERS(S) I GRAB BARS I MIRRORS) 1 ▪ FRP PANELS/ J- MOLDING I PAPER TOWEL HOLDER SANITARY RING HOLDER SOAP DISPENSER TOILET PAPER DISPENSER TRASH CAN BACKING FOR ALL ITEMS LISTED ABOVE AS REQ. ELECTRICAL L T C L T • • • • • • • • • • • • L T C L T • e_ • • • • • • • MT. i Y IT11A PIXTI1S / SALE ANNA L T C L T C STOCKROOM RESPONSIBILITY SCHEDULE L T C L T C L T C L T C C C REMARKS NOT USED NOT USED w I DEMISING PART. STUDS I G/ • • • • • • • • • • • • DEMISING PART. DRYWALL G/ • • • • • ITN' STORMOIINT RESPONSIBILITY SCHEDULE PUINIONID SNTALM MOST. FLOOFLOORING oo�o i RASE WALLS SALES WA LS FRAMIN BLOCKING GYP. BD. TOILET ROOM FRAMIN BLOCKING /GYP. BD. FITTING ROOM FRAMING BLOCKING /GYP. BD. FURRING AROUND COLUMNS AT DEMISE INTERIOR COLUMN FURRING GENERAL FURRING WALL PREP. AND PAINT BACKING AS REQUIRED DOORS MUM RODS L T C L T C L T C L T C INIMARKS L TC L T C L T C L T C L T C L T C L T C L T C SEE SHEET Dl. G.0 TO PATCH AND REPAIR AS REQUIRED ;9PYRIGHT . PSOTKL These drawings and specifications on copyrignt.d and subject to copyrlgM pro$.ctlon es on "arehlt.ctura. rorh under SSC. 102 Of the copyright Oct. 17 u.S.C. As amended december 1990. The protection inciud.s. 1rIMeut (Imitation. the outman form, orronp.ment and Composition of spaces. and elements of the design Under such protection. unauthorised use of these drawings end specifications may resuit In cessation of construction. building seizure. and /or monetary liabilit . v +No • 4- DATE: SCALE: DRAWN IIY: MONO ft.: 735 O'S- 4'9 -OS SHEET: S P3 "OS * 4 of I.1 41/4, • I LANDLORD DISTRIBUTION VERIFY AVAILABILITY FOR LOAD DEMAND PANEL _ ■ METER MAIN DISCONNECT ' AND FUSES _ , _ _ CONDUIT TO SPACE • G.C. TO UPSIZE IF REQ. VERIFY AT BID EXTEND CONDUIT WITHIN SPACE - I, WIRE TO SPACE G.C. TO EXTEND IF REQUIRED . L r A I r ■ . DISCONNECT WITHIN SPACE SEE ELECTRICAL FOR SCOPE PANEL L 0 -0 . , TRANSFORMER • RELOCATE . , PANEL H • RELOCATE HOMERUNS/ CONDUITS/ ' - ' tl CONTROLS: SWITCHES/ CONTACTORS CONTACTORS TEL. CONDUIT TO SPACE G.C. TO EXTEND AS REQ. VERIFY •N•UI Nr • • FOR P.O.S.! PHONE SYS. , HVAC SYSTEM RING AGE) (LINE AND LOW WI VOLT BUZZER SYSTEM i _ LIGHT FIXTURES J . T . KNOCK DOWN SYSTEM WHEN USED. SEE PLAN g _ 2v03 WALL - MOUNTED MIRRORS _ • HOOKS ON DOORS MAW COMER HOOKS ON WALLS TAG HOOKS - • • SEE DETAIL CAULKS/SILICONES/ 0 MA,STIQS /ADHESIVES - AS REQUIRED FIXED SEAT LEDGE • OWNER SIGNAGE # OF ITEMS, SHOPLIFTNG, ETC. ■ 4Il "M I 5 ? CODE RELATED SIGNAGE • AS REQUIRED le PLUMING / TOLET I EXTEND WASTE / VENT I LINES WITHIN SPACE EXTEND WATER LINES • ▪ WITHIN SPACE I LOCATE ACCESS WASTE STUB -UP WATER CLOSET & LAV. I MOP SINK. I DRINKING FOUNTAINS I FLOOR DRAIN / TRAP I PRIMER I WATER HEATERS(S) I GRAB BARS I MIRRORS) 1 ▪ FRP PANELS/ J- MOLDING I PAPER TOWEL HOLDER SANITARY RING HOLDER SOAP DISPENSER TOILET PAPER DISPENSER TRASH CAN BACKING FOR ALL ITEMS LISTED ABOVE AS REQ. ELECTRICAL L T C L T • • • • • • • • • • • • L T C L T • e_ • • • • • • • MT. i Y IT11A PIXTI1S / SALE ANNA L T C L T C STOCKROOM RESPONSIBILITY SCHEDULE L T C L T C L T C L T C C C REMARKS NOT USED NOT USED w I DEMISING PART. STUDS I G/ • • • • • • • • • • • • DEMISING PART. DRYWALL G/ • • • • • ITN' STORMOIINT RESPONSIBILITY SCHEDULE PUINIONID SNTALM MOST. FLOOFLOORING oo�o i RASE WALLS SALES WA LS FRAMIN BLOCKING GYP. BD. TOILET ROOM FRAMIN BLOCKING /GYP. BD. FITTING ROOM FRAMING BLOCKING /GYP. BD. FURRING AROUND COLUMNS AT DEMISE INTERIOR COLUMN FURRING GENERAL FURRING WALL PREP. AND PAINT BACKING AS REQUIRED DOORS MUM RODS L T C L T C L T C L T C INIMARKS L TC L T C L T C L T C L T C L T C L T C L T C SEE SHEET Dl. G.0 TO PATCH AND REPAIR AS REQUIRED ;9PYRIGHT . PSOTKL These drawings and specifications on copyrignt.d and subject to copyrlgM pro$.ctlon es on "arehlt.ctura. rorh under SSC. 102 Of the copyright Oct. 17 u.S.C. As amended december 1990. The protection inciud.s. 1rIMeut (Imitation. the outman form, orronp.ment and Composition of spaces. and elements of the design Under such protection. unauthorised use of these drawings end specifications may resuit In cessation of construction. building seizure. and /or monetary liabilit . v +No • 4- DATE: SCALE: DRAWN IIY: MONO ft.: 735 O'S- 4'9 -OS SHEET: S P3 "OS * 4 of I.1 41/4, • I KNOCK DOWN SYSTEM WHEN USED. SEE PLAN g _ 2v03 WALL - MOUNTED MIRRORS _ • HOOKS ON DOORS MAW COMER HOOKS ON WALLS TAG HOOKS - • • SEE DETAIL CAULKS/SILICONES/ 0 MA,STIQS /ADHESIVES - AS REQUIRED FIXED SEAT LEDGE • OWNER SIGNAGE # OF ITEMS, SHOPLIFTNG, ETC. ■ 4Il "M I 5 ? CODE RELATED SIGNAGE • AS REQUIRED le PLUMING / TOLET I EXTEND WASTE / VENT I LINES WITHIN SPACE EXTEND WATER LINES • ▪ WITHIN SPACE I LOCATE ACCESS WASTE STUB -UP WATER CLOSET & LAV. I MOP SINK. I DRINKING FOUNTAINS I FLOOR DRAIN / TRAP I PRIMER I WATER HEATERS(S) I GRAB BARS I MIRRORS) 1 ▪ FRP PANELS/ J- MOLDING I PAPER TOWEL HOLDER SANITARY RING HOLDER SOAP DISPENSER TOILET PAPER DISPENSER TRASH CAN BACKING FOR ALL ITEMS LISTED ABOVE AS REQ. ELECTRICAL L T C L T • • • • • • • • • • • • L T C L T • e_ • • • • • • • MT. i Y IT11A PIXTI1S / SALE ANNA L T C L T C STOCKROOM RESPONSIBILITY SCHEDULE L T C L T C L T C L T C C C REMARKS NOT USED NOT USED w I DEMISING PART. STUDS I G/ • • • • • • • • • • • • DEMISING PART. DRYWALL G/ • • • • • ITN' STORMOIINT RESPONSIBILITY SCHEDULE PUINIONID SNTALM MOST. FLOOFLOORING oo�o i RASE WALLS SALES WA LS FRAMIN BLOCKING GYP. BD. TOILET ROOM FRAMIN BLOCKING /GYP. BD. FITTING ROOM FRAMING BLOCKING /GYP. BD. FURRING AROUND COLUMNS AT DEMISE INTERIOR COLUMN FURRING GENERAL FURRING WALL PREP. AND PAINT BACKING AS REQUIRED DOORS MUM RODS L T C L T C L T C L T C INIMARKS L TC L T C L T C L T C L T C L T C L T C L T C SEE SHEET Dl. G.0 TO PATCH AND REPAIR AS REQUIRED ;9PYRIGHT . PSOTKL These drawings and specifications on copyrignt.d and subject to copyrlgM pro$.ctlon es on "arehlt.ctura. rorh under SSC. 102 Of the copyright Oct. 17 u.S.C. As amended december 1990. The protection inciud.s. 1rIMeut (Imitation. the outman form, orronp.ment and Composition of spaces. and elements of the design Under such protection. unauthorised use of these drawings end specifications may resuit In cessation of construction. building seizure. and /or monetary liabilit . v +No • 4- DATE: SCALE: DRAWN IIY: MONO ft.: 735 O'S- 4'9 -OS SHEET: S P3 "OS * 4 of I.1 41/4, • I le PLUMING / TOLET I EXTEND WASTE / VENT I LINES WITHIN SPACE EXTEND WATER LINES • ▪ WITHIN SPACE I LOCATE ACCESS WASTE STUB -UP WATER CLOSET & LAV. I MOP SINK. I DRINKING FOUNTAINS I FLOOR DRAIN / TRAP I PRIMER I WATER HEATERS(S) I GRAB BARS I MIRRORS) 1 ▪ FRP PANELS/ J- MOLDING I PAPER TOWEL HOLDER SANITARY RING HOLDER SOAP DISPENSER TOILET PAPER DISPENSER TRASH CAN BACKING FOR ALL ITEMS LISTED ABOVE AS REQ. ELECTRICAL L T C L T • • • • • • • • • • • • L T C L T • e_ • • • • • • • MT. i Y IT11A PIXTI1S / SALE ANNA L T C L T C STOCKROOM RESPONSIBILITY SCHEDULE L T C L T C L T C L T C C C REMARKS NOT USED NOT USED w I DEMISING PART. STUDS I G/ • • • • • • • • • • • • DEMISING PART. DRYWALL G/ • • • • • ITN' STORMOIINT RESPONSIBILITY SCHEDULE PUINIONID SNTALM MOST. FLOOFLOORING oo�o i RASE WALLS SALES WA LS FRAMIN BLOCKING GYP. BD. TOILET ROOM FRAMIN BLOCKING /GYP. BD. FITTING ROOM FRAMING BLOCKING /GYP. BD. FURRING AROUND COLUMNS AT DEMISE INTERIOR COLUMN FURRING GENERAL FURRING WALL PREP. AND PAINT BACKING AS REQUIRED DOORS MUM RODS L T C L T C L T C L T C INIMARKS L TC L T C L T C L T C L T C L T C L T C L T C SEE SHEET Dl. G.0 TO PATCH AND REPAIR AS REQUIRED ;9PYRIGHT . PSOTKL These drawings and specifications on copyrignt.d and subject to copyrlgM pro$.ctlon es on "arehlt.ctura. rorh under SSC. 102 Of the copyright Oct. 17 u.S.C. As amended december 1990. The protection inciud.s. 1rIMeut (Imitation. the outman form, orronp.ment and Composition of spaces. and elements of the design Under such protection. unauthorised use of these drawings end specifications may resuit In cessation of construction. building seizure. and /or monetary liabilit . v +No • 4- DATE: SCALE: DRAWN IIY: MONO ft.: 735 O'S- 4'9 -OS SHEET: S P3 "OS * 4 of I.1 41/4, • I I g :!f I ExTERmR1 .. ...,..,.�...�._ �....,.....�.. _.....�. I DEMOLITION PLAN I. REMOVE ALL ITEMS AS INDICATED ON FLANS. 2. CARE SMALL BE TAKEN =RI NE" DEMOLITION SO AS NOT TO DAMASE OR ALTER ANY EX I STI N6 STRUCTURAL MEMBERS. THE ARCHITECT AND OWNER SHALL Be NOTIFIED IMMEDIATELY IF ANY DAMAO! OCCURS OR IS DISCLOSED DURING DEMOLITION. S. IN ALL WALLS AND CEILINGS THAT ARE REMOVED, THE CONTRACTOR SMALL BE RESPONSIBLE FOR DISCONNECTING AT SOURCE AND REMOVING OR CAP'PIN', ANY ELECTRICAL, PLUMDINE►, 41PA5 LINES AND MECHANICAL DUCTWORK THAT IS DISCLOSED AND NOT SCHEDULED FOR REUSE. REROUTE AND CONTINUE ANY SYSTEM THAT MUST DE RETAINED FOR ADJACENT U I LD ING* AREAS THAT ARE NOT IN THIS CONTRACT. 4. AU. ELECTRICAL CIRCUITS FOR EQUIPMENT TWAT 15 TO DE REMOVED SMALL DI! DISCONNECTED AT SOURCE AND REMOVED. S. AU.. ',A5, WATER AND DRAIN LINES SUPPLYING EQUIPMENT THAT IS TO DE REMOVED SMALL DE DISCONNECTED, REMOVED AND CAPPED ABOVE CEILING* OR BELOW FLOOR. IF CONTINUITY' OP SYSTEM MUST DE MAINTAINED FOR USE el' ADJACENT AREAS, CONTRACTOR SHALL REROUTE, AS NECESSARY, TO D! DeMIND NEW CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOP'PING*.) to. THE CONTRACTOR SMALL DD RESPONSIBLE FOR REMpV I N', FROM THE SITE ALL RAWL S AND =DIRT S CAUSED BY DEMOLITION, AND OI SPOSI NG* OF IT IN A PROPER MANNER. DEMISING PARTITION WORK TO DE REMOVED SHALL BE PERP'OIRMED IN ACCORDANCE WITH LANDLORD'S CRITERIA. ALL INTERIOR DEMOLITION WORK TO Be 0'f TENANT'S b. REMOVE OR IRaELOGAT! ANY SPRI INO LINES, AS RlfSIJIIREP, IN PILO PER LANDLORD'S AND /OR LOCAL AUTHORITY APPROVALS. •AL CONTRACTOR TO COORDINATE WITI4 THE OWNER AND ARCHITECT AS TO TI4E DIEPOSITION OP ALL ITOMB TO Be REMOYED. 10. • E N I R A L CONTRACTOR SMALL L A T C H A N D REPAIR ALL G! I L I NG*S, MALLS AND FLOORS, AS REQUIRED, TO R!GeIV! NEW FINISHES. (0.C. TO MAINTAIN 14OUR PIR! RATED CONSTRUCTION THROU0110011T TENANT'S SPACE WHEN REQUIRED). ADJACENT TENANT MARSHALL'S GENERAL NOTES ADJACEXT TENANT AmERIC A'S BEST CONTACTS AND EYEGLASSES Ip Pr . \, ,� ��. If- G.C. DEMOLITION SUMMARY I. *SEVERAL CONTRACTOR AND /OR SUBCONTRACTORS SHALL REVIEW THE EXISTING* FACILITY TO DETERMINE THE EXTENT OF DEMOLITION REQUIRED TO INSTALL THE NEW WORK. A WRITTEN OUTLINE OF ALL REQUIRED DEMOLITION SHALL DE SUBMITTED TO THE OWNER DEGRIDINN THE FOLLOWING* MUT NOT LIMITED TO). 2. CONDITION OF EX I $TIN', POWER PANELS AND TRANSFORMERS FEASIBILITY POI! RELOCATION AND REFURDISHIN0S, OR NEED FOR REPLACEMENT DUE TO AG*E OR EXISTIN0 CONDITION. CONDITION OF EXISrTIN', SHEETROCK ON EXISTING* DEMISIN 0 WALLS AND RECOMMENDATION OF WHETHER TO REMOVE EXISTING OR Reuse TO DE DETERMINED IN FIELD. CONDITION OF EXISTIN', MECHANICAL SYSTEM FEASIBILITY OP REUSING*, RELOCATION, OR RE- • URDISMIN0 EXISTING* EQUIPMENT AND DUCTWORK AND RECOMMENDATION OP R!PLAGEMIENT, IF NECESSARY, PRIOR TO BID. SUMMARIZE RECOMMENDATIONS FOR REUSE OF EXISTING MATERIALS, EQUIPMENT AND AGGES- •ORIES, ONCE REPUIRBISHED TO A LIKE -NEW CONDITION, ITfMIZ! TIME GRMOIT TO THE CONTRACT, i. ANY UNNOTED EXISTIN S CONDITION WHICH CONFLICTS WITH THE PROJECT REQUIREMENTS AND MAY REQUIRE MODIFICATION, REL. OR REMOVAL TO GOMPL.ETZ TH! PROJECT SHALL DE INDENT - F I RD SO TH! NECESSARY ORAWI NG* REVISIONS MAY D! I NGORIDOIRATIL? INTO 'Ng 'P ROJCT RE- QUIREMENTS. 1. IN ADDITION TO THE ABOVE, 'WPM TO MORAL. DEMOLITION NOT % IN1PIGATCD ON timer* SP- i DIVISION 2 - DEMOLITION / WILDING* ALTERATION. TENANT ADJACENT MARSHALL'S lb KEYED NOTES SCALE: 1/4" z 1 8 EXISTIN', DEMISING PARTITIONS AND NEUTRAL TO 'REMAIN. SEE SHT. AI. EXISTING INTERIOR 0 !b TO O! REMOVED IN THEIR ENTIRTY. 0 Xl5TlN STOREPRONT ENTRY DOOR TO Se IN IT'S ENTIRTY. O EX 15TI N', ',LASS AND ALUMINUM STOREFRONT ANP ENTRY DOOR TO REMAIN. 0 'PORTION OF EXISTING DEMISIN0 WALL TO D! REMOVED. �✓ 0 REMOVE EXI$TIN{` 'PLOORIN0 MATERIALS FROM !XI$TINS► CONCRETE SLAB, 1:6: TILE, GAR'P'ET, TACK STRIP, !TG. SCRAM! AND OR **RIND SLAB TO A SMOOTH FINISH RrADY TO RECEIVE NEW FLOOR PINISH!I A$ DESGRIDED IN THESE PLANS. O REMOVE EXISTING* GEILING*S IN THEIR ENTIRETY, REMOVE ALL MIEMDEIRS FROM 'PREVIOUS STRUCTURES ADOV! CEILING* AREA (!.•. OLD DRAGIN',, TIC WIRES, OLD CONDUITS., ETC) 0 EXISTING* EXIT SERVICE DOOR AND FRAM! TO S! RLDMOVOO AND INFILLED. 0 EXIST. TOILET ROOM PARTITIONS, DOOM AND P'L.UMBIN', FIXTURE TO O! Rl4OVl2. NM 1104T. AI. 0 EXISTING* ELECTRICAL EQUIPMENT TO RELOCATED PER SHEET !I-ES. O EXISTING* ROOFTOP MVAG UNIT TO De RemoveD 0 EXISTINO 1111‘.41VRAI. COW TO REMAIN. r / / / / EXTERIOR MALL COLONNADE • cri Mp`l � , � 03 3 "1°1 37 DRAWN rt CQLLI4b - Thee* drawings and specifications ore copyrignted and subject to copyright protection es on `orchltect wore under sec. 102 of the copyright act. 17 u. S.C. As amended december 19110. the protection includes. without limhotion, the ovsroll form, arrongem.m and compoeltion of spaces. and elements of the design. Under such protection. unauthorised use of these drawings and specifications may reeuk In cessation of construction, building seizure. and /or monetary Mobility. 14110IKT 116.: 735 4 4•"" 05-09 -09 W: 1 /4 "+e l'-0" L•M1 A010116 D1 11 of I+ • • io AM VCSTIBW.e I STOCK ROOM AND PIALLMI AY: N0''I`: NOT USED IV O TYPICAL M 0 NON OL'ARINO INTERIOR PARTITION: NOTES: MAUVES AT NUM DEMONS PARTITION: N D'Tli: NOT USED 2=== 1 �' < =2=== TOILET ROOM / PLATFORM PARTITION: NOM: USE b" STUDS AT PLUP�IN6 WALL K %sr Aga TITIGAL rITT9N6IROOh *: Nom, AM Tv 101 AM rIJRRIN* AT EXIST1NO DEMISING PARTITION: NoTrS: ,aL;a:QtQa:Qc;i= i 0 MAUVES AT NUM DEMONS PARTITION: N D'Tli: NOT USED 2=== 1 �' <> = SALES ARIA 1 wrocoscotoom PARTITION: NOM& %sr 0 AM MALLMIIAY AT TOILET ROOM I VOTIS: NOT USED v, E ' HAL.LM AT SALMI AREA: NOTES: • HALLMIIAN' AT STOCKROOM; NOTES: S 9 I►\ a I NEW 5E1RV I GE .. DOOR. SW - DOOR 5GHI+DULE. INPILL AREA OF EXIST. SLR. DOOR. COLORS, MATERIALS = AND FIN. TO MATCH I r ADJ. AREAS. = NEW H.G. ACCESSIBLE TOILET ROOM WL/ NEW f- H.G. FIXTURES 4 ACCESSORIES. s!, /�ri- /.�i- /� Y��ii /, Wei /S /-iir/►' / �i�i-i.�i- /��ii�ii -ice ► /-i- /ice /��i- /ir��i-i,�i-. �r /,��,�►r�il �i-ii� -i_'i_ • O f// I GLR ' �/ I — 1 I rft , :vial I ■ a I � -- v = CC :E r O EXIST. ELECT. O. LOC... SEE ELECT. DW65. HEAVY DUTY HAN6ROD ON HEAVY DUTY SURFACE MOUNTED STDS3. SHELVES ABOVE. (SEE TYP. PET) I STOCK ROOM I NEW H.G. ACCESSIBLE TOILET ROOM W/ NEW H.G. FIXTURES 4 ACCESSORIES. cr 30" X 48" GLR. FLR. SPACE FOR DRINKING FTN. r r r r D•4 I 2 1 -'7" / 3'-0" 12" r _` I r v ar y TOUT ROOM D-6 ION ' 18" <ta \7 ' o-a TOLET ROOM /1 GLR. r, r 0 O I I I I I I • I I 1 ILEUM. EXIT SIGN ABOVE. see REFLECTED GL.6. PLAN XFMR. ON STOCKROOM FLOOR LOG. SEE SHEET EI. 48" X 56 "" GLR. FLR. SPACE FOR TOL I ET. (TYP). 30" X 46" GLR. FLR. SPACE FOR LAV. (TYP) . 1 12" 1 4 25 STANDARDS • 16" O.G. * 2 I , ADJACENT TENANT i 6'-b" FLOOR PLAN KEY SYMBOL b 5 41' -5" I HALLWAY - NEW H.G. DRINKING FOUNTAIN. 1 -10" 11 WALL LEGEND KEY SYMBOL 15 0 • re LINE OF SHOE SHELVI N6 UNITS. see SHEET A2 N 2 1 -1 " 1 1 -Z N WALL STANDARDS • 24" O.G. W/ METAL BRACKETS. SL"t TYP. PTE. FLUSH WALL MT=7. ILEUM. EXIT SION ABOVE. SEE SHEET E I . ,1 -2 " R.O. D-3 1FA41 51-0 GLR. -..� 100' -5" EXISTIN6 CONCRETE FLOOR SURPAGE PREPARE FOR INSTALLATION OF NEW FL00RIN6 MATERIALS AS INDICATED IN THESE PLANS. SEE SHEET SPI FOR ADD. FLOOR PREPARATION NOTI:g. --...,,,,\ 2 -6N R.O. D-2 IF.R.31 5 NON- TAIIIlD WALL STANDARDS • 24" O.G. W/ METAL ORAGKETS. SSE TYP. DTL. IsALEs AREA] N of 2 R.O. D-2 51.4 N ge N F.R., D-2 5 /Nil I " , 26 sum • 24" O.G. EXISTIN6 STRUCTURAL COLUMN AND ENCLOSURE. FINISH TO DE MF - ? . 6Y1 BD FITTING ROOM PARTITIONS TO 9'-b" (1 TYP. DETAIL 'ADJACENT TENANTI CUSTOM GASH MAP UNIT. SEE FIX. PLAN w EXIST. DEMI5IN6 PARTITION PATCH 4� REPAIR TEN. SIPE ONLY AS REQ'D. lium TERI EXIST. DCMISIN6 PARTITION PATGM 4 RIM�'AIR Ter. SIDS ONLY AS nap. II STANDARDS • 24" O.G. * 32 KEY DESCAPTION Ej STOCK ROOM TO TOILET ROAM: 5'-0" x 6' -8" x 15/4" S.G. PAINT •RADE WOOD DOOR WITH I -1/2 PAIR M.D. BUTTS AND 6/9 LEVER TYPE PRIVACY SET 4 DOOR CLOSER. (DOOR, PRAMS, MARDWAIM AND INSTALLATION BY TL'N. 6.G.) El REAR SERYIGE DOOR NEM 5'-o" x 9'-o" 4140L1..Or4 METAL DOOR 4 FRAME. APPLY NEW PANIC HARDWARE SUPPLIED BY OM ER. PROVIDE A DOOR CLOSER, SMOKE GASKET'S AND LABELED DOOR AS REQUIRED O.C. TO PAINT INSIDE 4 OUTSIDE OF DOOR 4 FRAME. HINGES TO HAVE NON - REMOVABLE PINS. PROVIDE ALUM. THRESHOLD 4 WEA'TI4E RSTRIPPIN•. PROVIDE A COMPLETE 60 MIN. ASSEMBLY. PROVIDE DOOR YlEMlMt AND LAB,. REAR OF DOOR "PAG•UN" AND SPACE NO. NOTES: EXIT DOORS SHALL OE OPENADLE FROM THE INSIDE W I T'MOUT THE use OF A KEY OR ANY SPECIAL KNOWLEDGE OR lFPORT MAXIMUM PULL PORGIES FOR INTERIOR AWD EXTERIOR DOOR SMALL NOT EXCEED: s LOS. POR INTERIOR DOORS 1.5 LOS. !OR EXTERIOR DOORS LINO or SOPPIT ADOV! •.G. TO INSURE THAT 6/9 FLOOR L060 DOES NOT INTERFERE WITH SIENSORMATIG ANTENNAS WOE L I •HTED TYPE ILLUMINATED EXIT SIGN ABOVE. SEE SHEET E3. 1/2" DEEP DEPRESSIONS FOR SENSORMATIG •RID 1'!N. •.G. TO GOORD I HATE WITH SYSTEM I NSTALLER.000RD I NATE FLOOR WORK WITH MALL OPERATIONS. EXISTIN6 CONCRETE FLOOR SURFACE PREPARE FOR INSTALLATION OF NEW FLOORIN6 MATERIALS AS INDICATED IN 'THESE PLANS. SEE SHEET SPI FOR ADD. FLOOR PREPARATION NOTES. (sates AREA LINE OF SOFFIT ABOVE a I mr..=2===:Wa DOOR SCHEDULE NON- TA5DGD WALL STANDARDS • 24" O.G. W/ METAL BRACKETS. I See TYP. DTL. KEY oeaGirnoN 0-1 STOCK ROOT, , TO TOILET' ROOM: I' ;N 4'-6" ca L 24" 1 1 -N 4 1 -N Noy SCALE: 1/4" ! HO" EXISTIN6 NQ,TRAj", PIER !XI STI N6 *LASS AND ALUMINUM STOREFRONT. NEW PORTION OP &LASS AND ALUMINUM STOREPIRONT. DOLOR, FINISH AND MATERIALS TO MATCH EXISTING. LOC. Or 6R-I5 ANTENNA ON FLOOR. GOOMRD I NAT! A/ THE SYSTEM INSTALLER EXISTIN6 STET CONSTRUCTION. G/L OF EXISTIN6 6LA3S AND ALUMINUM DOOR. EXISTIN6 GLASS AND ALUMINUM STOREFRONT. EXISTING STOREFRONT CONSTRUCTION. &—__- LEASE LINE EXISTING GLASS AND ALUMINUM STOREFRONT. EXIST. NEUTRAL PIER & AtSS AND ALUMINUM DOOR: EXISTIN5 ISLAM* AN, ALUMINUM DOOR. MALL rl1'T111I1i IROOM DOOR: 2'-b" x S'-O" x 15/8" S.G. PITTIN• ROOM DOOR GLAD WITH I4go. STAINLESS STEEL. DOORS, JAMBS, AND !PUTTS SUPPLIED BY P.G. L'E'VER TYPE LOCKING HARDWARE SUPPLIED BY OWNER. 6.0. TO INSTALL. (NOTE: 6.G. IS TO INSTALL, ON THE SALES AREA SIDE, AN OWNER SUPPLIED STEEL GOAT HOOK IN THE CENTER OP THE D0001, I" DOAN FROM Tie TOP TO THE TOP OP PLANitSE. ® PITTING ROOP I DOOR: (M.G,) 3' -0" x S'-O" x 1 /6" SG PITTING ROOM DOOR GLAD wino 'Ago STAINLESS STEEL. DOORS, JAMBS, AND BUTT'S SUPPLIED BY P.G. LEVER TYPE LOGKIN6 ofttotprtmite SIIJPPLIED BY OrMIER. GG. TO INSTALL. (NOTE: O.C. IS TO INSTALL, ON THE SALES AREA SIDE, AN OMER. SUPPLIED STEEL GOAT HOOK IN Time CENTER OF THE DOOR, I" =?OYMN PROM TM! TOP' TO TM! TOP irrlF PLAN•e. ® SALES AREA TO HALLMIIA ' / MALLMIIAY TO STOCKROOM: • x 6' -8" x 15/4" S.G. PAINT &RAtiE Fi000 OOOR MIITH i -t /2 PAIR M.D. BUTTS AND 5/5 LEVER TYPE PA*SA•E SET • MITM SELF GLOSIN6 DEVICE. DOOR, FRAME, INSTALLATION AND LATGMSET a, TIN. 6.G. NO LOCKS PERMITTED ON THIS DOOM ° I03 - • 13/ r CITY OF TUKWILA MAY — . 9 2gn3 PEIVir I, 735 QYNIGHT NOTICE; These drawings and speeifkotions on copyrighted and subject 10 copyright prohecton as on 'orchhecturai wort` under sec. 102 of the copyright oet, 17 U.S.C. As amended december 1900. The protection includes, without limitation. the overall form. arrangement Ond composition of space*. and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of conshuction, building seizure, and /or monetary 'wow', u2 1 1;4"14 1 = ci a aq . d ?. • DATE: CONAN /I': PNO*CT NO.: i.• 1 1g CI ' iiips 4.9.0 IFI 5 .1( f 1 06 -O9 - SIarT: 1/4"a1 LPM Al i CC 0 u. O I New senvic.e. SEE S•T. Al. INFILL AA OF EXIST. sow. Doom. COLORS, PINISH ANP NATERIALS TO MATCH ADJ. AREAS. GTRIGAL. !G. AND TELEPHONE EV. LOCATION see sfierr el. XFMR ON TOILET ROOM PLATFORM LCIC. SEE SHEET El New H.C. TOILET ROOM 1041TH NEW H.C. 6RAIBI BARS AND PLUMBIN6 FIXTURES. exisT. paralytics PARTITION PATCH 4 REPAIR TEN. slpe ONLY AS NEW •.C. TOILET NEW H.C. DRINK'S* ROOM WITH New H.C. FOUNTAIN. 6RAB BARS AND PLUM5IN6 FIXTURES. FIXTURE / FLOOR FINISH PLAN riry4p , . SMALL litemititSERATOR FURNISHED AND INSTALLED BY OWNER. BULLETIN DPS. (VERIFY LOC. bo4/ OWNER) OFFICE DESKTOP SHELVES ASV. AND SAFE (BY OWNER) 6.C. TO BOLT TO FLOOR FACE OUTWARDS. •ABBEDWALL STANDARDS • 24" O.G. WITH CUSTOM METAL BRACKETS SEE INTERIOR eLevAnotis. EXISTIN6 STRUCTURAL COLUMN AND eNcLosutite. 1 46" HIGH SLIDINS stioe SHELVIN6 UNITS BY 'SPAGEMASTER'. SIZE AND QUANTITY PER L.AN. INSTALL PER MF6RS. RECOMMENDATIONS. • LINE OF METAL. STUD ANP OPYP. BP. FITTING ROOM PARTITIONS. 10 NON-'?A1 O WALL STANDARDS • 24" Q.G. AIT14 &ATOM MILiTAL BRACKETS Sil INTERIOR ELEVATIONII. Raft:10 1 I • 1 4. • ", 111111 1 • in ow • 7 1.1 - • . " • • • ........ +46" KOOKS • +60" A.F.P. (TYP.) Th 4 COAT HOOKS • +60" A.F.F. l '4—WAYP DISPLAY PIXTUROS (TYPICAL) 34" +416H H.C. TRANSACTION SURPACE WOOD FITTING ROOM SEAT LED6E. FURNISHED BY PACSUN INST. BY 6.C. 1IS NON—TABBED WALL STANDARDS • 24" O.C. WITH CUSTOM METAL BRACKETS see INTERIOR ELEVATIONS. SCALE: 1/4" 2 I '- NOM:. MAINTAIN MINIMUM ES" AISLES BETWEEN PIXTURES. PER A.D.A. REQ. NOT!: PAINT ALL EXPOSED eferr. DD. WALLS IN STOCKROOM 1 I. ...■•••■■■••11111111mtemam L.INg OF DISPLAY MANNIMIN OWNOR) dIPLASS AND ALUMINUM STOREFRONT eacmioN %%kW OZ. TO MAIrG44 ADJACENT AMA.. exisnms •LASS AND ALUM. geromemoNT sYs.rem exit:MINE, STORWRONT CONSTR.UCTION. GeNTentLiNe exisTINIS ALUMINUM AND &LASS DOOR. 46" PIA. INLAID STAINLESS sures. rs. 1.060 IN 20" X 20" TILE SEE TYPICAL =TAIL. LINO OP SOPPIT ABOVE. LEASE LINO EXISTING ("LASS AND ALUM. STOREFRONT SYSTEM EXISTIN6 STOREPRONT CONSTRUCTION. EXISTING 6LASS AND ALUM. STOREPRONT SYSTEM LINE OP DISPLAY MANNEQUIN (SY OWNER) ID3.1347 gOrYitiGHT mairx These drawings ond spocificotions ot* copyrighted on subject to copyright protection os on "architectural work" under stn. 102 of the copyright act, 17 u.S.C. As amended decay**. 1,00. Th. protoction includes. without limISOticM, OvOr011 form. orrOngement arid COrnpoSinon of SpOCOS. and elements of the • C•sign Undor such protoction. unauthorised use of these drawings one specifications may result Ir. cessation o t construction. building seizure. and/or trion•tory DATE: SCALE: OMNI Irt. PROJECT NO. : 735 • COW•Crt .479 SHEET 1/4"•I' —Cs" 1.1.1 ACOORO fit .1 m Y.* 1 8 A2 0 141 • us • I. * I I II I 1 2 I MAXIMUM COMPRESSION STRUT SIZES WE AMAX HT 1/r$Xme OA. 36.4" s/4 "$XEEGA. 4.-r r0x2o i 6 1 y4'' x 20 GA. •41" 1 ter 0xso re" r $ x 20 CIA. t+-s 2 yr$x1sQA 104 r$x1s truer s yr f x is a , ar-r ill TRANSFORMER ON TOILET ROOM PLATFORM. SEE ELEC. VASS. T -BAR GRID CEILING CONTINUES OVER TOP OF TO I LET ROOMS. EXHAUST FAN. SEE SHEET MI (TYP) x l.� J •r•ON AFF. SUSPENDED GL6. NCO ...�_. _1111._. 1111111111• 1:1111• BEM ..■ ►M■■ ■..■ 11•11■ NMI ■.■ U■■ .... ■11111 NNE U.. U.. MIN ■■■ ■.. MEM .r. ■... MINUS •••• I o i..■ •=. ...• - .. - ■.11■ •.1• H H2 H2 $ 4 e.+.• s+r•. ■1111 ■ e./ ■ ■..■ ...■ ...■ 11111111 NNE ■.. 2■. ■.■ ■.. OMNI 1 1 1 N N so rxr l- l 6YP. BD N i UNVMMi I •7 APP. ......��+r....w.•�. ++1111+..- •�.►�,wwnrrw+wn M N X -+ XI ge mow PLAT Y i n w.... rr.,., , , . . ..�r.u.....��.+�..... EXHAUST PAN. SEE SHEET MI (TYP) REFLECTED CEILING PLAN KEY SYMBOL DESCRIPTION LIGHTING TRACK SECTIONS (!Ni3rTH AS INDICATED ON PLAN). SURFACE MOUNTED EXPOSED TUBE FLUORESCENT LIONT STANDARD CEILING MOUNTED ILLUMINATED EXIT SIGN. ILLUMINATED GLASS BLADE EXIT SIGN CONVERTIBLE TO MULTIPLE APPLICATIONS. INSTALL AS SHOWN ON PLAN. *WAGE MTV. DUAL HEAD ! LIGHT UNIT YM/ COMPACT BATTERY PACK. TOILET ExMAUST PAN. SEE SHEET M -I SUPPLY AIR DIFFUSERS (TYP.) RETURN AIR DIPPAER Mt"). - -- w .,�.."....... �...�.. - ••• SUSPENDED CL6. 61LID 1r mot, SUSPENDED GL.&. 60!10 • XI LINE OF SHOE SHELVIN6 UNITS BELOW. SEE SHT. A2 CLG. PLAN SYMI OL LEGEND OL LEGEND KEY SYMBOL ■ ■.. Al U NN ■.■ S G E c G 1 „1 ■ii • a •.I $41 U,.. M� •p0• RECESSED INCANDESCENT DOWN WOW'. 9IAX FLUORESCENT FIXIVRE VW CLAMP-ON TRACK LIONT FIXTURE AT STOREFRONT. SUSPENDED LAP*. 'BACKYARD TYPE' LAMPHOLDIER RECESSED FLUORESCENT LISHT FIXTURE IN SUSPENDED WALL MTV. VAPOLET FIXTURE suotrAce MOUNTED FLUORESCENT LIONT FIXTURE - CAULK TO CEILINer AND PAINT SIDES P-I DESCRIPTION • TRACK MOUNTED LIGHT FIXTURE. (TYT) LINE OF PITTING ROOM PART! TIONS BELOW. CI ig CL 11"' -Or AF.F. SUSPENDED GL.6. GRID CEILING TYPES SALES AREA - LAY -IN AGGOUSTIGAL CEILING SYSTEM: "U56" DONN DX INTERMEDIATE DUTY 24" X 24" X IS /16" SUSPENDED WHITE T-&RID &RID SYSTEM AT HLEIGMT AS INDICATED ON PLANS Yr/ 'USG" EGLIPStE #'76113 24" X 24" X 5/4" SMADOWLINE TAPER EDGE UL APPROVED PLAT WHITE AGGOUSTIGAL CEILING TILES. SEE SHEET A -dI POR SEISMIC BRACING DETAILS WHEN REQUIRED. NOTE: THIS IS A DIRECTIONAL TILE ( ARROWS TO POINT TO REAR OP SPADE ). ST / HALLWAY - LAY -IN AGGOUSTIGAL CEILING tr*TlM: "US." DONN DX-I. 24" X 4b" SUSPENDED AMITE METAL T-GRID SYSTEM, AT MEIONT AS INDICATED WITH STANDARD WHITE 24" x 45" LAY -IN ACOUSTICAL NON- TEGULAR CEILING TILES. SEE SHEET A4 POR SEISMIC s7ETAILS WHEN REQUIRED. TOILET ROOM - SYR. W.: 5/b" TYPE 'X' OYP. !Br►. G! I L I NG. ON METAL STUD FRAMING PER IPL.ANS. TAPE .JOINTS SAND SMOOTH, PREPARE SURFACE PO* PAINT PINION IST011111FIRONT SOFFIT - GYP. Or.= S /b" TYPE 'X' ONT. 90. CCIL,INii ON 9-3/b" X 20 . MCTAL. STUDS AT 16" O.G. W/ TAPED JOINTS SANDED SMOOTH. PROPANE PO% PAINT PLACEMENT OP SPEAKERS AND AUDIO EQVIPOMENT TO BE BY TFR '00!! cow.' ENE, AND MILL *TRIM, TO OE PROVIDED BY G.C. SE! 'DOSE C.O. RP' D RAMINGS POR PLACEMENT. APP. I illNlNDimD GL.IO. MiD TRACK MOUNTED L I6HT FIXTURE. (TYP) I x h I ab 1n I 111 I 1A I SCALE: I /4" a I'-c" Amp 1SNSORMATIG' RIADOUT DEVICE • 6" s1LOW CLG TRACK L I GMT MG. ATTACHED TO !X ISTI NG GLA$5 AND ■ ALUMINUM S � NU A :T '.T • , APP S /b" Df 'X' GYT. BD. SOFFIT, INIAINT EXISTING STOREPRQNT CONSTRUCTION. TRACK L I&»$T SEC. ATTACHED TO EXISTING *LASS AND ALUMINUM STOREFRONT. EXISTING STOREFRONT CONSTRUCTION. v-s.. A.F.F. 5/8" TYPE 'X' GYP. 50. SO1'FIT, FAINT TRACK LIGHT SEC. ATTACHED TO EXISTING &LASS AND ALUMINUM STOREFRONT. 91 1)0 4 "----137 ! U ' t ) • I, a 011 Of - 1 0 ON 2 7 203 rotu RIOSIVID MYOF'MONA 01 PERMIT CENTER 735 COPYRIGHT NOTICE; Thou drawings and spacltkotions ors copyrigntsd and subject to copyright preNetlon as an * architectural *ore under see. 102 of the copyright act, 17 u.S.C. AU omsnded decsmber 1550. 'he protection includes, without IlmMatlon, the overall form. arrangomsnt and composition of specs. and elements of the dssegn Under such protection. unauthorized use of thee. drawings and specifications may ',suit In eessotion of construction. building seizure. and /or monstary liability -C V ■ 4 +•• DATE: DAMN tl► IIIOIECT Pis.: • II 00-0 ,-09 ma: 1/4 "s I'-Q" LPM e c$F 1'6 .rawM11wr I a a LIAS! Lim! ---" - 0 :Y,,, iig1:Y/.Y.4. - --_■ - - - -■ - ---- - - -_■ - -- -1111 - ---- - - - -■ - -_-- - - --■ ■■---- - -__- - - - -■ ■■ —■■■■ ■■--•■■■ •11111111111111•1111 111111111111111111111 ■■—■■—■■ 1 - --111111■ 1k11 —■--- 11■■—■■111111■ -i -•1111—■■ ■•--11111■ ■11,1—■■■■■- tt EXI5TIN6 GLASS AND ALUMINUM STOREFRONT SYSTEM TO REMAIN STOREFRONT ELEVATION V di 6" DIA. 'FS' VINYL ADHESIVE' TRANSFER LO6OS ON GLASS - "3M *2I0 -324 FROSTED CRYSTAL (SAND- BLASTED LOOK) APPLIED TO 6LASS AT 36" ABOVE FINISH FLOOR. (FURN. BY OWNERS SIGN CONTRACTOR., INST. BY 6.G.) TYPICAL WHERE SHOWN. M AL NIA SION AT LANDLORD DRSISNATUD ARIA. S.G. TO %w arm ar TM! LANDLORDS' SION GRI TRR I A AND *MAT SHOP D*AAINOS FOR me PROPOSuD SI•N TO TM! LANDLORD AND ANY OT1SR •OVURNIN• AUTHORITIIES. TN! S.G. MALL SL'GUR! ANY AND ALL *URMITS Rl4UI'R!D FOR ml INSTALLATION AND DISPLAY OP TM! FROPOSID *IONAAI. EXISTING STOREFRONT CONSTRUCTION TO REMAIN. EXISTIN6 6LASS AND ALUMINUM STOREFRONT SYSTEM TO REMAIN PROVIDE! SION LITTORS AT TM! MAXIMUM BIZ! Al ALLOY., lY' TM! LANDLORD. AWRY • b" DIA. 'FS' VINYL ADHESIVE TRANSFER L0605 ON GLASS - '3M *210 -324 !FROSTED CRYSTAL (SAND- BLASTED LOOK) APPLIED TO 6LASS AT 316" ABOVE FINISH FLOOR. (FURN. BY OWNERS SIGN CONTRACTOR., INST. SY 6.G) TYPICAL WHERE SHOWN. I h GEILIN6 HANGAR WIRE SEE DETAILS 5HT. AF 35/b" x 20 6A. METAL STUD DIA6IONAL BRAG IN6 • 46" O.G. • 45° TO FRAMING ASV. (AS SHOWN) SUSPENDED AGGOUSTICAL TI LE CE IL I N6. SEE SHEET AS 3 5 /b" x 20 ga. METAL STUDS • 16" O.G. TO FRAMIN6 ABOVE. 3 /b" 'TYPE "X " GYP. BD. OVER 3 -5/6" X 20 ga. MET. STUD FRAMING AT 16" O.G. RECESSED L I OHT FIXTURE. (WHERE OCCURS) EXISTING •LASS AND ALUMINUM sTooterlitowir SYSTEM TO REMAIN EXISTIN6 ALUMINUM AND &LASS DOOR W/ FULLS TO REMAIN. TENANT I STOREFRONT SECTION NEAL EX I STI N6 GLASS AND ALUMINUM STOREFRONT SYSTEM TO REMAIN / I T vensoof J NEW FORTION OF GLASS AND ALUMINUM STOREFRONT SYSTEM. COLORS, MATERIALS AND FINISHES TO MATCH ADJACENT AREAS / / NEW SION AT LANDLORD DESIGNATED AREA. S.G. TO REVIEW THE LANDLORDS' SION CRITERIA AND SUBMIT SHOP DRAW I N65 FOR THE *1!0'r05ED SION TO THE LANDLORD AND ANY OTHER 60VERNIN6 AUTHORITIES. THE S.G. SMALL SECURE ANY AND ALL PERMITS REQUIRED FOR THE INSTALLATION AND DISPLAY OF INC PROPOSED SI•NAGE. EXISTIN6 MALL BULKHEAD EXIITIN• STOREFRONT CONSTRUCTION TO REMAIN N . BY OWN LIAM L1N1 7 1 D . 2)03 our 3T SCALE : I /2 "a I'-O" CM' Of TUB ,APPRO'VE0 MAY 2 7 2403 As hump 0 ,Noom It4 ,4 y • y rtapnea SC AL! I/2 "• I . .O" Itr I COPYRIGNi NOTICE; Those drawings and specifications ore copyrighted end subject to copyright protection as on `orchM.ctu►ol •o.. under sec. 10 o the copyright act. 17 u.S.C. As amended docombor 1990. The protection includes. without limitation, the overall form. orrang.mens and composition of specs*. and • smints of the design. Under such protocton. unauthorised use of 'him. drawings and specific Lions may result In cessation of construction, building seizure. and /or monolog hhobiIity. DO MMr NY: IIIDIECT No.: 735 AOl0046 A4 • 4 ..+,r.,. • _... DRYWALL P I TT I NO ROOM WALL TO '1' -i" A .P.P. RIGE$*!D WALL EXIT *ION IS" ADV. TOP Or POOR PRAM§ / %.9 ' `.'' 'fire "#z 9 //Y „ r;% ' %f '•�'p y gal ;I I T -STAT • 48" O.G. W/ LOGKIN6 COVER. INTERIOR ELEVATION V TOILET ROOMS SMALL CONFORM TO ALL A CCESSABILITY REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT (ADA) INCGLUDINO BUT NOT LIMITED TO THE •O1.1.O1 A. WATER CLOSET SCAT M!I&MT - 19" TO III" A.F.P B. CENTERLINE OP WATER CLOSET - lb" FROM SIDEWALL. G. BRAD DAR DEMIND WATER CLOSET - 941" LONE, - *99 -96" A.F.F. I7. IMAM DAR DIAMETER - I'I /2" C. &RAO DAR AT SIDE OP WATER CLOSET - 42" LONE,, 99" TO 96" A.F.P. SPACE BETWEEN E,RAB BAR AND WALL - 1-1/2 " &. TOILET PAPER DISPENSER - 96" MAX. PROM REAR WALL, 1E" MIN. A.P.F. M. KNEE CLEARANCE AT LAVATORY - APRON 21" MIN. •T., b" MIN. DEPTH. I. LAVATORY oLr' '4 - 19" MIN. .1. LAVATORY DRAIN AND MOT WATER PIPES - INSULATED WHEN EXPOSED_ K. LAVATORY RIM SUR1"AGE - MAX. 94" A.P.P. L. MIRROR BOTTOM EOM - 40" A.P.P. MAX. M. INTERNATIONAL. SS'YMBOL OP AGGL'SSADILITY SMALL BE MOUNTED ON THE EXTERIOR OP The TOILET ROOM POOR. N. POOR MARPMrARE *MALL BE LEVER TYPE. 34" x ID" X I /6" DIAMOND PLATO KICK PLATE W/ MP -I FINISH FASTEN TO DOOR W/ SELF THRCADINS SCREWS. •.1. .. .in.,,,...a,.. ...,.. O.. wM.. 4....11.1.•..:> ....«.,.....w+. • - • - . , .�.�...r.. e. . P -I 42" i I NOT ALL exioyeeD WPM"LY AND DRAIN • PIPES A RS TO BE INSULA1110. � y b" MIE,M BLACK RUBBER BASE n lb" X 9b" MIRROR TOLET ELEVATIONS 'rADDIV AALL STANDARDS. WI TM METAL BRACKET'* AT 24" O.G. O!! $NS!T Al 6" HIbH BLACK RUDDER BASE INTERIOR ELEVATION INTERIOR ELEVATION • S' -0" r ' Is" SCALE: I /4 "a l' -0" 46" MI&M WHITE WAINSCOT WITH TRIM GAP (TYPICAL 4 WALLS) 96" BAR \ • N!W PORTION OP OLASS AND ALUMINUM STOREPRONT. DOLOR, PIN, AND MATERIAL TO MATGN EXIST. INTERIOR ELEVATION CXISTINS &LASS AND ALUMINUM DOOR AND DTOREPRONT. .. v'. .:, /y /r ,:.::,'?.:. ... .. r r ...: .{/r /.F .. .,. :..� .. r '� �r/ rte'" i, '.r% :�, y .. r: //, .J'yi. .,r' t � .sail' ./ Y.,+^' r ;yr rr / / r .r y . 44/. `r � ,Gri., ,v0 r NON- TADDED WALL STANDARDS. WITH METAL BRACKETS • 24" O.G. SEE SHEET Al. WALL STANDARDS. AT DISPLAY WINDOW W/ *APHID DISPLAY 1'"° I XTL*! 1 0 WI BOT. OF MIRROR I NOTE PROVIDE CLEAR SILICONE • SEALANT AROUND ALL ITEMS IN PITTINS ROOMS. ANYWHERE A !FRIG! TAO COULD BE INSERTED. EX. TOP a BT'M. OP SEAT AROUND HOOKS, MIRRORS, *IONS, DOOR JAMBS, ETD. • SCALE: 1/4" • 1 NON - TABBED WALL STANDARDS. WITH METAL BRACKETS • 24" O.G. SEE SHEET AI. 4r 'MAX. 4 ITEMS ' SION 6" ABOVE HOOKS. APPLY W/ CLEAR SILICONE TO WALL VAPOLET El I XTUIRCS SEE L I&HT FIXTURE SCHEDULE. 'SHOPLIFTING IS A GRIME' 510N. APPLY TO MIRROR Mr/ FOAM TALC aN CLEAR SILICONE (TYP CAGM P.R.) 24" x 60" CLEAR MIRROR SECTION MT. EA. PITTINS ROOM) PROVIDE CLEAR SILICONE DEAD AROUND PERIMETER TO WIALL. CINGM M!I•MT ---4 6" WI•M SLACK RUDBlR DA*!. 6" MIOH SLACK RUDDER BASE TAO HOOKS ON WALL SE! TYP, DETAIL. P- * - I ea C@. EQ141— eQ i I LINE OP BACK OP VINYL 'PS' L060 ON *LADS SCALE: I/4 ":I F.G. SUPPLIED METAL GOAT HOOKS SCREWED TO DOOR FAGS IN CENTER►, PLAMSe I" DOWN FROM TOP. SCALE: I /4" = I'-O" I I'-b" II 1'-O" SCALE: I /4 " =1'-O" I GiATOM WOOD ''ITTINE, ROOM SEAT i.EDle SENSO*MATIG READOUT DEVICE 6" BELOW 6Y0. GEILINS 6" MI6H CLACK RUBBER BASE 6" $ 416M BLACK RUBBER BASE Cn Of BOO t4 Al 2 7 24 m v INTERIOR ELEVATION ..1 1: ) 0 ftir t 3? isommo coprorrunvitA i i ` i '3 SAT MOM DATE: 735 w W Z 5 COpYRICOIT NOTICE; TMs* drawings and specifications on copyrigngd aria subject to copyright protection as on "architectural r0 ,y• under sec. 102 of IM copyright act, 17 u.S.C. as amended december 1lf0. TM protection inc ludas. without llrnitetlon, the overall form. arrangement aria composition of spaces. and eietnents of the design Under such protection, unauthorized use of tn.s. drawings and specifications may result in cessation of construction, building seizure. an /or monetary nobility V +1• : COMM K: PROJECT No.: 0411 Of -01 -O5 SME#T: 1/4" : PM A5 10 Of l I NOT USED NOT USED DILL 5/52" HOLE FOR I /8" BOLT I LOCK NUT AFTER CEILING IS LEVELED. (4) b OA., 45 SPLAY WIRES, AT EVERY STRUT, I2' -0" O.G. EA. DIRECTION. MAIN RUNNER J SUSPENDED STRUT DETAL • ANCHOR TO STRUCTURE ABOVE 8 OA. VERTICAL 1•IAN6ER WIRE • 48" D.G. 1/2" EMT. COMP. STRUT T16HT TO STRUTT. ABOVE_ COMPRESSION STRUT REQ'D. • EACH SEISMIC RESTRAINT I2'-0" O.G. EACH WAY. 3/4" EMT NOTCH OVER MAIN RUNNER. GROSS TIT SCALE: I I/2 "= I'-0" SCALE: SCALE= I I/2 "• 1'-O" I I /2" G.R. CHANNEL AT 48" O.G. ATTACH 5 -5 /b" METAL JOISTS TO CXISTIN& STRUCTURE ABOV!. EXISTIN. 6LASS ANp ALUMINUM STOR!PRON 5 /a" TYPE „ X" dYPIQM BOARD WITH TAPPCD JOINTS SANDED SMOOTH. 3 5/8" x 20 ga. METAL STUDS • lb" W/ 5/8" TYPE 'X' GYP. BD 1/2" EMT. COMP. STRUT TI6HT TO STRUGT. ABOVE. C0MPESSION STRUT RCQ'D. AT EA. SEISMIC RESTRAINT 12 0.C. CA. WAY. NOT USED STOREFRONT HEAD DETAIL STRUT AT GYP. BD. �LRIG DETAL 3/4" EMT ANCHOR TO STRUCTURE ABOVE. LEASE LINE SCALE: I I /1 I ' - 8 6A. VERTICAL HAWSER WIRES • 48" O.G. EA. WAY. DASHED LINE I P4 I GATES 5/52" HOLE DRILLED FOR DOLT AND LOCK NUT AFTER GEIL1N6 IS LEVELED (4) b 6A., 45° SPLAY WIRES AT EVERY STRUT, 12 O.G. EACH WAY. 1/6" METAL HAT CHANNELS AT 4" D.G. PERPENDICULAR TO G.R. CMAM�ELS. HALF SIZE SCALE: !" • 1 • JAMB AT NEUTRAL PIER II NOTE VERIFY THAT THE SHOWN METHOD Cr ATTACHMENT IS ACCEPTABLE WITH THE ON -SITE COORDINATOR. IF NOT, CONTACT ARCHITECT POR ALTERNATE DETAIL. EXIST. I RMI`INS PARTITION WALL STANDARD W/ DlGO. MTL 0111AGKlTS. 111/0" TM1011 ' 4Y1'. OD. OVER METAL SPUDS. EXISTING •LASS AND ALUMINUM STOREFRONT. LEASE LINE EXISTING NEUT1tAL PIER 2" X 5" X I" STEEL CLIP ANGLE ATTATGHEP WITH (4) *10 SCREWS. 9 5/8" X 206A. D IA6IONAL BRAG IN6 • 4PS ATTACHED TO CLIP ANGLE W/ (2) *10 SCREWS. TYP. DIAGIONAL BRACING CONNECTION 1 VERTICAL STRUT, MAY BE STEEL STUD, SLACK IRON, EMT OR OTHER APPROVED EQUAL 6000 POR UP TO 4 1416H. 8 &A. WIRE SPLAYED IN FOUR DIRECTIONS • 45 • 12 O.C. EA. WAY. b 6A. VERTICAL WIRE HANOER • 4 O.G. CA. WAY, TYP. GE I L I N6 PANELS, TYP. NOTES: I. V!IRTIGAL, STRUT: A S RUT FASTENED TO THE MAIN RUNNER, SHALL BE EXTENDED I PAST!'NC'D TO THE ST11tuGTURA4., !UP"POMRTINS THE ROOF OR •LO0R ABOVE. 'He STRUT SMALL 011 ADESIUATE TO RESIST THE VERTICAL. COMPRESSION INOUGCD dY THE ORAGIN` AIRSS. 2. THESE HORIZONTAL RESTRAINT PFOI NTS SHALL Se PLACED 12 OR LBO* O.G . I N SON DIRECTIONS WITH PPOINTS WITHIN 6'-0" FROM ANY' WALL. l SCALE: H /2 " EXIST. ROOT DECK. VERIFY LXAGT GOND I TI ONS IN THE FIELD. N.T.S. TYPICAL CEILING SUSPENSION PYOTE111 SCALE. 1 •1/2 "a I'•O " eb PLAN ATTACHMENT TO STRUCTURE ABOVE 4 3 l�.E1IATION cXIST, l211MISINS PARTITION i /i" rein 'x' ow. gyp. OVER METAL STUDS. WALL STANDARD A/ DECO. MTL BRACKET$. --- ---....... Ns\\ eXISTINS &LASS AND ALUMINUM STOREFRONT. LEASE LINE EXISTING NEUTRAL PIER JAMB AT NEUTRAL PIER NOTE V!R11 Y THAT THE SHOWN METHOD OP ATTACHMENT IS ACCEPTABLE WITH THE ON -SITE COORDINATOR. IF NOT, CONTACT ARCHITECT FOR ALTERNATE DETAIL. ' H - -- I I I 44 4'-o. H- 6 " 12' -0" MAX. 4' -0" MIN. A" FI FLOOR SPEtED ca.INw BRACING a" 52 AF SUSPENDED GEIL INS. . "1)0 1 3 SCALE: I -I/2 I'-0" /7 „....---EXIST. ROOF DECK, VCRIPY EXACT CONDITIONS IN THE FIELD. EXIST. BAR JOIST OR STRUCTURAL MEMBER. VERIFY EXACT coNvITIONS IN THE FIELD. VERIFY THAT SPAG I N6 IS ADEQUATE FOR THIS TYPE OP APPLICATION. UNISTRUT BEAM CLAMP TYPE 2164, TYPIGAL. UNISTRUT TYPE P5000 CONT. 200A. STEEL CHANNEL A/ 2 I/2" TOES CONN. TO UNISTRUT WITH *10 SCREWS • 24" O.G. 5 5/8" X 2090. STEEL STUDS • 24" D.G. SCALE: 9 " * I " Q COMPRESSION STRUTS •17-0" D.G. EA. WAY 3/8" MIN. CLEAR GROSS RUNNER OR MAIN RUNNER \\Ak'j MIN. D oSAU6E WIRE'S. 2-1 2C VA v • ---0 NIMOVED �CIT1► T1J�W��1 MAY - ^3 4 fq *GALA. !" • I -0: 735 ;oPYIIIG4T _MIIIKL Those drawings and spocilications ore copyrighted and subject to copyright protection es on 'orchhoctura, 'Orb • under sec. 102 of the copyright act. 17 u.S.C. As amended decombor 1910. The protection includes, without limitation. the overall form, arrangement and composition of spaces, and Woments of the desiyr Under such protection, unauthorised use of these drawings and spoclflcotlons may •*suit In cessation of construction. building s*isurm, and /or monetary liability DATE: SCALE: PI1oJECT No.: • • Z 0 16 1 6 — 1 i g'.. CI " I l'i s I I 0 aii i ;; AS 70 A6 $ WO" x 20 OAuelt DIAdONAJ. BRACINS. • 46" O.G. • 45° ALT'!RNAT! •IBIS GONT. 111-S /8" x 2091. TOP TRACK w/ (I) I IO 'MK $G*gW EA. STRAP BRACINS. (VERIFY EXACT GOND • 46" O.G.) NO STOMAS! Hove coRPuooa GOVT. 5 -5 /6" x 202a. TOP TRAG *2'-0" NO GYP BD. REQUIRED V-0" 3-5/b X 209a. METAL STUDS •24" O.G. I HALLWAY 5/8" TYPE "X" ••P. BD. TAPE, SAND, PREPARE FOR FINISH PER ELEVATIONS. GOVT. 20 A. BOTTOM TRACK w/ 'HILT!' ON OR DS SHOT PIN INTO SLAB AT 24" O.G. (I .G.5.0. *256b) BASE PER PLANS EXISTING CONCRETE SLAB STOP OYP. WALL SECTION HALLWAY / STOCK ROOM 20ga. 6" METAL TRACK BAGKIN6 AT EACH WALL STANDARD LOG. -- 5/6" TYPE "X" 6Y0. BD. WALL 5URRAGE. SINGLE SLOT HEAVY DUTY STANDARD W/ I" SLOTS AT 2" O.G. USE FLATHEAD SELF TAPPING SCREWS. ATTACH AT PROVIDED HO LES. 2 " X 2" "L" ANGLE W MP -I FINISH 4 CLEAR GOAT. ('TYP. BOTH Sloes) METAL STUDS PER SHEET AI METAL STUDS PER SHIFT Al 5/8" TYPE "X" 610. BD. OR GMU WALL SURFACE. (VERIFY) I" X 4" PIKE TREATED HORIZONTAL WOOD PURRING STRIP AT 12" O.G. SGINIW TMIRL WT. BD TO EA. STUD USE •ELF TAPPINS PLAT MEAD SGREAS. USE TAPCONS IP ATTAGMINS TO A CIAO SURFACE MEANS" DUTY DOUBLE SLOTTED &APACE MTP. AALL STANDARD A/ ORUSHIED ALUMINUM FINISH. SCREW TO MARINO STRIPS JN/ SELF TAPPINO PLAT NEAP SGARI,NIS. STOCK ROOM 1/2" = 1 1 -0 " WALL STANDARD - SALES WALL STD. -STOCK RM. r t♦ N.T.S. N.T.S. SW. AI EX I •TIN. METAL PAN DECK VVRIPY EXACT CONDITION. CONT. 54/b" x 209o. TO* TRACK w/ (I) I" • 10 TEK SGRIA EA. STRAP DRAGINS. (VERIFY EXACT GOND • 40" O.G.) DO NOT PENETRATE ROOF DECK OR INSULATION. SUSPENDED ACOUSTICAL TILE GC" ILIN6 IN SALES AREA *2 SUSPENDED ACOUSTICAL TILE GEILIN6 IN HALLWAY 5/8" TYPE "X" GYP. BD. TAPE, SAND, PREPARE FOR FINISH PER ELEVATIONS. 5 -5 /6" x 20ga. METAL STU175 .24" D.G. (ALIGN w/ STANDARD PER ELEVATIONS. (SEE SHT. AI) GONT. 20 6A. BOTTOM TRACK w/ 'HILTI' DN OR DS SHOT PIN INTO SLAB AT 24" O.G. (I.C.B.O. x2586) BASE PER PLANS EXISTING CONCRETE SLAB WALL SECTION SALES / HALLWAY I SALES AREA' TIMELY METAL DOOR FRAME AND JAMB DOOR, SEE SCHEDULE •TOP SYR. ST f3YP. 'HALLWAY! 1/2" = 11-0" 5/b" TYPE "X" doffs. BD. BOTH SIDES OVER 5 -5/8" METAL STUDS. TYP DOOR JAMB / HEAD DETAL wry ROOM wAu I" = 11,,,0" 4 GONT. b "x Ibga. TOP TRACK b" x Ibga. METAL STUDS •Ib" O.G. BASE PER PLANS. (BOTH SOW EXISTING CONCAVE SLAB WALL SECTION HALLWAY / TOLE, ROOM PROVIDE CORNER BEAD P=FORL' TAPE AND SPAe:ALE 1/2 = 11-0" CONT. 18 A. BOTTOM TRACK w/ 'MILTI' ON OR DS SHOT PIN INTO SLAB AT 24" O.G. •HT. AI EXISTINS METAL PAN DECK VEIRIPY EXACT OW ITION ..........) GONT. 10h5 /10" x 204a. TOP TRAGIC w/ (I) I" M IQ T!K ISCR Mr EA. STRAP •RAGI NS. (VERI PY EXACT GOND • 46" O.G.) DO NOT PRNETRATE *OOP PICK OR INSULATION. f SUSPEND!!D ACOUSTICAL TILE GEILINS IN STOOK ROOM SUSPENDED ACOUSTICAL TILE GEILINO IN SALES AREA 4 . 12'-0" 5 3/8" 'TYPE "X" OYP. BD. TAPE, SAND, PREPARE FOR FINISH PER ELEVATIONS. I SALES AREA I 5 -5/8" x 20ga. METAL STUDS • 24" 0.C. (AL I ON rv/ STANDARDS PER ELEVATIONS. (SEE SMT. Al) GONT. 20 6A. BOTTOM TRACK w/ 'HILTI' DN OR D5 SHOT PIN INTO SLAB AT 24" O.C. (I .G.5.0. *2368) BASE PER PLANS EXISTING CONCRETE SLAB WALL SECTION SALES / STOCKROOM WALL NOTE: ANY WOOD USED IN GONST'RUGTI ON MUST BE NON- GOMBUSTABLC (PIRE TREATED). 1 -1/2" x I -1/2" x 20ga. METAL 'L' AT 1206E OF PLATFORM PRL I METER SCREW THROUGH TOP INTO PLYWOOD USE ALL HOLES PROVIDED. 5/4" FIRE TREATED PLYWOOD SGREW THRU TO STUD' W/ 2 -1/2" LONG SELF TAPP I N6 COUNTERSUNK SGREWS AT b" O.G. AT BOARD SD6ES, i 12" O.G. FOR THE FIELD 5 /6" TYPE "X" 610. BD. b" X Ibga. METAL STUD - HOISTS. •Ib" D.G. VERIFY DIRECTION 5/b" TYPE "X" 6Y0. BD. TAPE, SAND, PREPARE FOR PAINT GONT. 3 -5 /b" x 1b90. TOP TRACK NOTE GEILINS JOISTS SHALL • ALIGN DIREGTLY OVER WALL STUDS. 5 /b" TYPE "X" GYP. BD. TAPE, SAND, PREPAR! POR FI NI SM O'ER ELEVATIONS. USE W.P. ' RM' SYP. BD. IN TOILET M. --r- PJ -5/8" x IOgp. METAL STUDS •16" O.G. ---,. U1! 0" x 1690. STW • PLKO MIALL GONT. It► OA. BOTTOM TRACK w/ 'HILT!' ON OR D• SOOT PIN INTO SLAB AT 24" O.G. (I.G.B.O. '2506) p STOCK ROOM SCALE: 1/2" • 1 -0" ITOLETI SAt! PM PLANS lxIfTlw GoNGIlTe 111.A0 WALL SECTIONG TOM NOON / wA,.oRM 1 1 1 1 STOP 6YP. STOCK ROOM 1 /2" • I'-O" B AS! P!R PLANS GO'NT. 20 SA. BOTTOM TRACK w/ 'HILT!' ON OR DS SHOT PIN INTO SLAB AT 24" O.G. (1.G1.0. *2506) E XISTINS CONCRETE SLAB 5 -5 /D" x 20ga. METAL STUDS •24" O.G. 5 5/8" X 20 6AU6! OIA6ONAL BRAGINb. • 446" O.G. • 45 ALTERNATE SIDES. SUSPENDED ACOUSTICAL TILL' GE ILI N6 IN STOCK ROOM- 5/6" TYPE "X" (WO. BD. TAPE, SAND, PREPARE FOR PAINT FIN. WALL SECTION FURRING AT NEW DEMNQ WALL 1 /2" = 1 -0" GONT. 5-5/8" x 209a. TOP TRACK *PER PLAN 1 . ""Noom 4 STOCK ROOM IXISTIN4, METAL PAN DICK VERIPr EXACT CONDITION EXISTIN• I-MMR. DEMI•IW6 WALL NOV-465.) S.G. TO PATCH AND REPAIR AS RIKOUIRED. MAL ANY NEW PENETIIATION• w/ AN AP- PROVED MATERIAL. GOVT. 5-5/6" x 20g0. TOP TRACK SUSPENDED ACOUSTICAL TILE CEILING IN SALES AREA *2 5/8" TYPE "X" 6Y0. BD. TAPE, SAND, PREPARE FOIR FINISH PER ELEVATIONS. 5-5/8" x 20ga. METAL STUDS •24" 0.C. (ALIGN w/ STANDARDS O! ELEVATIONS. (SEE 5HT. AI) GONT. 20 6A. BOTTOM TRACK w/ 'HILTI' PN OR DS SHOT PIN INTO SLAB AT 24" O.G. (I.G.B.O. x2586) BASE PER PLANS- EXISTING CONCRETE SLAB !SALM AREA] WALL SECTION 4> FURRING AT EXISTING D N° WALL I/ = 1 X11 /�1:.1b..M.oMMIdoIMSG: D�1A1MMY ok 0 1 � "%1 MY OP A.114•11A MA,' - S 3 Misr F• as IO Sq-v 13'7 WALL SECTION � VESTIBULE h - HOUR RATED 1/2" • I. -0 I COPYKiIiT NOTICE; Those drawings and specificotbns ors copyrighted ono subJOCt to copyright pro$sction as on +orchNocture* were undo, sec. 102 of the copyright Oct. 17 u.S.C. As ori+Onded decombsr 111110. The protection includes. wlfhout IlmKoflen, the Overall form. Or►angel•nt and composition of spaces, and • smOnts of the Osman. Under such protection unauthorised use of these drawings and specifications may mei* In cossotior of construction, building seizure, and /or monetory liability DATE: SCALE: P O I D A E C T DWAIN IN: 735 410 OS -01 -OS : ssmi"....”. A7 Aosoft I OP .5 7 1 itt a �� 4 NOT USED NOT USED PLO AT OUT TO TILE WI TH INSTANT PATCH GONG. UNDERLAYMENT PATCH I /2 "- 1' d a 4 4 v CONCRETE TOPPING S/S LOGO NOT USED �,.� ,,,,s,nw��.k ... «. «.....w.■.. err. .. «...- •,.........,.....••.....w + «.«.. ,..•••∎•• ,..w. V 4 RECESSED S/S FLOOR 1.060 ELEMENT BY S.G. CONCRETE TOPPING EXIST' N6 CONCRETE SCALE: - N.T.S. N.T.S. N.T.S. • = 1 �'1 I R'1 1 • 1 1 NOT USED EXISTING CONCRETE NOT USED 1 f I Il STOCK (ROOM GLOP. (041414S OGC.UR& S!! REPILIGTtp GLi. PLAN PM IXAGT i4 I•MIT. I" X 4" PIR! TREATED MO*IZ. PION TR*ATW WOOD MOUNTINOP STRIPS AT 13" O.G. (4) 9/4" PI*!' TR!'ATW, Ii" DEEP PARTICLE 5D. SMlLVINOP = ON H.D. STANDARDS 016" O.G. ti 4 ISRAGKETS. 6 H.D. STANDARDS • Ii" O.G. MAX. H.D. STEEL HANG ROD. (TYP) • +34" A.P.P. 4" HIGH RUSSER BASE TYP. ELEV. @ S.R. HANGRODS, SHELVING V.C.T. TO CONCRETE TRANSITION • r N.T.S. SCALE: 3 "= I' -0 " ALUM. TRANSITION STRIP V.G.T. PLOORIN6 (SEE SPECS.) *GAL', - N.T.S. h 4... f..-2" MAX. 00" A.P.P. O SAFE BY OWNER. 6.G. TO DOLT TO FLOOR. STOCK AOOM GLOP. (1/44S*I OCCURS) St! R!P'LIGTRO GLi. PLAN PO* eXAGT MSI•MT. I" X 4" FIRE MATED I' ORIZ. FIRS TRIATW PIOOD MOUN 'IN• STRIPS AT 12" O.G. J -BOXES I OUTLET • +a0 POI ST'ERSO iCN . S!E $MT. E I (4) f /4" PIRO TIIIIATsP, Ii„ PEEP PARTIG1.E DD. SWELVINO ON N.D. STANDARDS • 16" O.G. 4 4 ORAGKlTS. i' M.D. STANDARDS • Ii" O.G. 4 PLASTIC LAM. GLAD DESK TOP 4 ENDS. I "' " DIA. MOLE IN DISK 11 T OP W/ PLAS &ROM!T I PILE GAB. BY OWNER TEL. 4 1 OUTLETS (SEE ELEC. CVOS) 4" H10H RUM** BASE TYP. ELEV. @ STOCKROOM DESK CONCRETE TOPPING NOT USED • 5, 34" • PLC. PITT1N6 RM.) 0 12" 0 CLEAR SILICONE DEAD 9/16" MAPLE SEAT DULLNOSE EDGE 2 X WOOD BRACES Z' X 3" WOOD LEDGER 6 T I- . I AAL5 . VERIFY CONDITION FITTING ROOM SEAT DETAIL r4 211101/41111/41.21/4/411/11111M/1121/ w !it a; a. 4 N.T.S. SCALE: N.T.S. /b" TERRAZZO STRIP 1 CLEAR FINISH V.G.T. PLOORIN6 (SEE SPECS.) EXISTIN6 CONCRETE CONCRETE TOPPING / VCT TRANSITION M.T.S. SCALE: !" I 11/4" M.P.P. TQP 14430. METALL !BACKING IN WALL +60" • •6" P OR ATTACHMENT OP WALL HOOKS TAG HOOK DETAIL &ROUT JOINT CONCRETE TOPPI NO FLOAT OUT TO TILE WITH INSTANT PATCH GONG. UNDERLAYMENT PATCH I /2 " -I -0" 44 SMR'T VINYL PLOOR I N• IN TO I L.ET DOOM 4 4 1 PROVID! GUAR SILICON! MAD PLASTIC, LAM PINI$M (Amin) PROVIDE 3" DIA. MQLE IN DESKTOP •/ *ROMST ('P'OR GORDS) SCREW INTO WALL DAGKIN& • 12" O.G. &YP. DD. WALL 3/4" M.D.P. END PIOGL'S, (BOTH amps). SECTION AT STOCK RM. DESK 4" 1 4" 1 4" VINYL TO V.C.T. TRANSITION 1 "MAXI 4 ITEMS IN PITTING ROOM" 916N. 0 *IGK *5-21 I HEAVY DUTY HOOK X4. SCREW TO 1 PLATE •/ SUPPLIED FASTENERS. SCALE": 1/2" s: 1 L L c M SCALE: N.T.S. 1/6" TERRAZZO AN&LE •/ CLEAR FINISH TILE FLOORING ( VERIFY THICKNESS CM O T�U► LICWI MAY 2 7 2UO3 EX' STING CONCRETE AS t Li) CONCRETE TOPPING TO TLE FLR'G. SCALE: N.T.S. t 3g DOOR IN CLOSED POSITION 2" X 1/2" MARBLE 'TMRESHOLD PIECE STRIP GENTERED UNDER DOOR V.GT RLOORI140 IN STOCK ROOM ✓ CORRIDOR. ICE SPECS.) �oRY � A MAY - 3 2003 EXISTINN GOMGRlTE Mow. Site' 735 COPYRIGHT _MUM Those drawings and *Pacification* ors copyrighted and subject to copyright protection as on 'orchNkt„roi sort" under sec. 102 of the copyright Oct. t 7 O.S.C. As amended decomber 1990. The protection include*, without limitation, the overall form. arrangement and composition of spaces, and eismonts of the design. Under such protection, unauthorised use of these drawings and specifications may result in cessation of conetructIon, building seizure. and /or monetary liability al. = rim ::C/3I era �z a cJ EL. •23.vibrag. Ig s u -1 0 ID 1 I :+1.! t:1 " I i :Ili 11111 to iwid I 7 $ 4 • a • lig all 1 1 •"; (4) MECHANICAL PLAN (NEN 14". 77 •••••-••••••••••11••••■•••• • Allan•••••••-• 1•11••••••••••••■•••••••••••••••••••••••••••••••■■••• • • • ••••••••••••••••••••••■••••••••••••e•••••••••• .••• .••••• .••••••••••••••. iv. ' 16". 10". 4 1 1 4. 12xI4 . ..... . . 16" —4 1 12"• 12x14 12"• .. .. ... . 16x16 • El 16 ". 4 s . s ... I1...27 's/ 4' 1 / . 22 —4 ea. •01•• wart r 12• 1 ••••••••••4.. ..•4•10*.suiltomigiX,,,,MON/O 12". C.O. yy 1 MOD MM. NOW ..•• r • (TYP 4 -- 4 iimmisomm.4i1..5.5wommmmmmmiotow0.01w000mmtiimiktissiaicAmpsto.mmaitetow; • s - ss - ; 27 72' ‘7 / // .4" . f11 I /7 /7 7 / 7 4 , Z .M•10 •I=M 1 1 1 „,04. 400 for elm, •••• aim ems mi., woo 1s1* ..; . 401.00 ,•••••••••••441 • 0) s 1 !! A 44 -4— , 4 f \iNK \\\_\ • . l‘ 1 / ./ r 4.4 • 1, . /.• .. UMMW um. 'EL gom• sow gimp .44 1 () DUCT 111'410KE IMPTECTOR. • - ...... • 7 t—ssist-4 1 12"0 1A) MEAT1NO ONLY' SETSIACK ThIRMOSTAT. KEYED NOTES • •••••••i-i OE 24X24, 12". TOCK GP-I. BALANCE TO GPM NOTED. 24X24, 10". NECK CD-2. BALAW4E TO GI! NOTED. 0 24,424, 22x22 MCI( RO-I. 24x24, 22x22 NECK . • ...... ,........•••••••••-•••••• •-STAT. 'PROVIDE VW CLEAR 'PLASTIC LOGIN COVER. COORDINATE EXACT LOCATION WITH ARGOITECTS INTERIOR ILEVATIONO. 9/4" 40NMNOATIN PAIN LINO DONN IN IINALL TO LAVATOIlltr TAII.P1•41. ® 0"• TOILET' EXMAUOT UC1' U THROUOM IROOP TO GAP. LOCATE GAP MIN. l0 AWAY PROM ANY OPRZI*1 AIR INTAKE*. PIMP VERIPe. ® NEVI PULL. SIZE lbA 1 RA DUCTS DOAN THROWN.' EXIOTINO ROOF 01 PROM NIA *OOP MOUNTED MEAT PUMP. 24 MOM TIMECLOCK. COORDINATE EXACT LOCATION WITH ARiG•ITECTS INTERIOR ELEVATION*. SEE PIIRINO 12IAORA161 ETAIL ON SHEET to12. Irwrir SCALE: 1/4" (1_1) NIPS ROOFTOP PAGIKAIRD MEAT PLP 4I• UNIT TO INPLACI EXISTING ROOFTOP' Iii'ACKAOCO A 41T RIEV4IORK EXISTING EXIOTINO 1 AN OY10111 141111041 G4 AO cLI TO ACCOMMOCIATO NON UNIT PIMP 1/1111,111Pr. 1 GOPYRMIL !CUM These drawings and spocifkations are copyright.," and subject to copyright protection es an earchltecturat soar under sec. 102 of the copyright oct, 17 u.S.C. As arnonded december 11100. The protection includes, without limitetIon. the overall form. arrangement one composition of *swot. and • elements of the ississir Under such protisction, unouthorlzod use of rtusb. drawings and specifications may result In e01110 of construction, building seituro, ond/or monetary liabilit moimmoilli■•■■■■ DATE: SCALE: 01110,411 NOWT No.: 735 1 $OW 1/4".1'4!" S TAPP M1 IA 0 11 ( 1 ire TRANE HVAC EQUIPMENT PACKAGE INGUJOIll ALL TRAM hINAG EINJIPMENT AND MATED Meilike01111111 wGM A/► GL IM THERIMOSTATS, + *'m , I'VG.. AS IPIIIGIPINI ON THE PLANS AND SPECIPIGATIONS FOR PAGIPIG lI1AIR. POR GOMPLET! INFORMATION ON TN§ PACIFIC SAM AR IQ UITNONIT PACKAGE CONTACT THE NATIONAL AGGOUNT EXECUTIVE AT TRANE NATIONAL ACCOUNTS: PAIIIIGK MONSON/ "WM GALLASHAN TRAM! NATIONAL ACCOUNTS I1160 ROW-AND STREET CITY OP INDUSTRY, CA 4 11146 PHONE: (b241) 43 -II16 DIRECT LINE PHONE: (bib) 662-.161I TOLL FREE PAX: 42b) 4 118 -24b4I PA•1! : 426) 4 180 -58 EMAIL: riaagegailtinalitidate TGALL.AdMAN1•TRANR.GOM ANY GMANbES OR VARIATIONS TO THE ORIISINAL EQUIPMENT PAGKA6E THAT WOULD AFFECT T'1 HV EQUIPMENT PACKAGE SHOULD BE BROUGHT TO THE ATTENTION OP THE ACCOUNT EXECUTE V! AT TRANE NATIONAL ACCOUNTS. THE &MORAL OR INSTAL.LIN* CONTRACTOR •URCHASES THE EQUIPMENT PAGKAAE DIRECTLY PROM THE TRANS COMPANY. TIC WAG CONTRACTOR WILL DE RESPONSIBLE 1•OR FIRST YEAR LABOR WARRANTY, DELI VERY COORDINATION, IRlGCI VINE AND INSTALLATION AS pESCRIdlD IN THE SPECIFICATIONS. r L N H J • 10111111111PACININ 1111Thall111111111firlaCERIM PABILwseeerMEs MANE WARRANTIES ALL PARTS FOR A PERIOD OF ONE (I) YEAR PROM INITIAL STARTUP OR lb MONTHS FROM DATE OF SHIPMENT, WMIGHEVMR OCCURS FIRST. CERTAIN EQUIPMENT HAVE COMPONENTS THAT INCLUDE AND EXTENDED WARRANTY LON6ZR THAN ONE (I) YEAR. TRANE PART'S WARRANTIES BELON6 TO THE EQUIPMENT OWNER. 24 HOUR MECHANICAL TIME CLOCK "IN'IEIRMATIC" MODEL TI09 DOUBLE POLE SIN6LL THROW TIME CLOCK 24 VOLT TRANSFORMER H 120 VOLT AG TIMER POWER SlNOL.E POLE SINGLE THRC7W NORMALLY CLOSED RELAY. (TYPICAL) CONNECT TO HOT POWER TERMINALS AT A/C UNIT AND MATINS/ AppL,INb ONLY 'THERMOSTAT SUBBASE MIGN. Of ALL UNITS. -\ H H i r --- 1 !J1 I I AC UNIT LJ I I I AG UNIT I 1 1 L �J r - - 1 !I 1 1 AC UNIT 1 L J -1 SETBACK I THERMOSTAT 1 HEATING ONLY SET -BACK THERMOSTAT. HEATIN6 MODE SET TO 60°1m 2/G * lb THERMOSTAT WIRE IN CONDUIT ('TYPICAL) DOUBLE POLE SI N&L.! THROW MAbNBTIC CONTACTOR. N40TL: ALL WIRING AND STARTERS Al R INGL.UPL'L7 IN THE ELECTRICAL DIVISION OP THESE IFIGATIONS, BUT ALL CONTROLS, RELAYS, ETC., AIRS INCLUDED UNDER THIS DIVISION. ROOM THERMOSTATS AND CONTROL SWITCHES SHALL BE LOCATED AS SHOWN OR DIRECTED, AND ALL CONTROLS, RELAYS, STARTERS ANID WIRINb SHALL GONPORM TO THE NEC. ALL CONTROLS SMALL DE FURNISHED AND PROPERLY' IDENTIFIED, WITH INSTRUCTIONS FOR PROPER ELECTRICAL CONNECTIONS. RESPONSIBILITY FOR PROPER CONNECTIONS AND OPERATION I5 INCLUDED HEREIN. HVAC TIMECLOCK WIRING DIAGRAM COLD CLIMATE HEATING SETBACK N.T.S. MANUPAGTURER MOL7EL TRANE WIK046 TRAM INDOOR 91•0011114 OIROS. GOO1.INS GAP GPM 1600 1600 1600 ' H . taw - taleNI Or I SO 0.9" I Ib.M 0.9" 1 95.4 TOT 11.2 11.2 S.2 ENT. AIR POP • 50 50 50 MEP b1 61 61 HEAT NOW 91 .11 81.5 O.S.A GPM 400 400 400 MARK HP -1 MP -2 HP-S NOTES: I. SEIZE ALL UNITS ON SUMMA! AMBIENT T!MPlRATURl: err. WINTCIR: 21°P. 2. UNIT POWER: - VERIFY VOLTAbl/ PHASE WITH ELEGTRIGAL DIRAWINOS. 9. COO1J6 CAPACITY, MINIMUM MOAT CAPACITY AND GPM AIRS MINIMUM OUTPUT FREQMJIRED. ALL UNITS SHALL HAVE NO LESS THAN alb% OP THEM CAPACITIES. GOOL.INS CAPACITY IS (ROSS COIL CAPACITY REQUIRED (ARAN HEAT NOT DEDUCTED). 4. PROVIDE ROOF MOUNTINd CURD, FILTERS ANp PILTEIR RAGI( SIZED Al" 800 FPM VELOCITY. S. PROVIDE WITH 100% ECONOMIZER WITH 100% POYeRED RELIEF AND ON/OPP THERMOSTAT WITH SETBACK. b. CONNECT CIRCUITS *11 4 12 TO TIME CLOCK FOR SETBACK MODE. we WIRING PlAdIRAM THIS SHEET. AREA SERVED TOILET ROOM TOILET ROOM MANUFACTURED! MR/DAN 'ROAN MODEL. 664 564 GPM DO b0 C.S.P. ( "W.G 0.125 0.125 MOTOR HP PRAC. PRAG. V/IRH 120 /I 120/1 BAROMETRIC DAMPER YES MARK 'L'F -I EF -2 NEW ROOFTOP PACKAGED FEAT PUMP OMIT NEW GRILLE, REGISTER, AND DIFFUSER SCHEDULE PESCR I PT I ON MANUPAGTU MODEL GMILIN S DIFFUSER TITUS PAS GEILINb DIFFUSER TITUS TOG RETURN &RILLE TITUS 2311 (RETURN 6IRIL I TITUS PAR MATERI AL STEEL STEEL STEEL STEEL MODULE 24 "x24" 24 "x24" 24 "x24" 24 "x24" BACK PAN SIZE Ib "xlb" 25.5 "x29.5" 25.5"x253" 29.5"x295" BORDER TYPE LAY -IN LAY -IN LAY -IN LAY -IN FRONT BLADES 4-WAY PERPORATED PERFORATED MARK CD-I op-2 R6 -I R6-2 NEW EXHAUST FAN SCHEDULE TAIL AROUND SNLJ66LY Z WRAPS PRIOR TO INSTALLIN6 LINE STRAP LAY-IN GEILIN6 PLEXIeL! DUCT MAX. 4'-O" LEN6TH 2" ROUND S.A. DUGTMVORK ABOVE CEILIN6. SEE PLAN FOR DUCT SIZE. IN WIDE x 20 6A. STRAP W/ TI6HT!NIN O SCREW SECURE STRAP W/ SHEET METAL SCREWS 9" O.G. MAX. ■ 1_ PRIOR TO CONSTRUCTION/ SID THE CONTRACTOR SHALL VIS :T THIS SITE AND FIELD VERIFY THE EXISTIN6 LOCATIONS AND SIZES OF ANY LANDLORD PIIOVID!!D, OR EXISTIN6, OUTSIDE AIR INTAKES THROU6M ROOF, LANDLORD PROVIDED CHILLED/HOT WATER PIPING MAINS, TOILET EXHAUST MAINS, OUTSIDE AIR DUCTWORK, CONDENSATE LINE MAINS, ETC. THE CONTRACTOR SMALL FIELD VERIFY ANY/ CONDITIONS WHICH MAY GONPLIGT WITH THE D!!5I6N SHOWN ON THESE PLANS. NOTIFY ARCHITECT IMMEDIATELY. FSIOM'T' (LW) •25 $25 $25 DAMPen O1''roseD BLADE OPPOSED BLADE NONE NONE 24 "x24" " TITUS" MODEL * TI7G, ROUND NECK (SEE SHEET MI FOR NECK SIZE) BORDER TYPE 9- LAY -IN DIPFUSERR DRIVE DIRECT DIRECT N.T SQUARE SUPPLY AIR DIFFUSER DETAIL . ALL mow SMALL COMPLY WITH ALL APPLIGAsLI FEDERAL, STATE AND LOCAL 40015, LAM, ACTS AND ALL AvinvA,ITIIb MAVINi JJRIWIGTIONI, AND LANDLORD'S GIRITSIRIA. 2. MECHANICAL GENERAL NOTES TIC COMPLETED INSTALLATION SHALL O! IN ACCORDANCE WITH ALL APPLI- OAK S INDUSTRY STANDARDS OP 0000 PRAGTIGI AND SAFETY; AND TM! MANIUPACTURl*'S STRICTEST RECOMMENVATIONS PORI EQUIPMENT AND PAO- DUCT APPLICATION AND INSTALLATION. i. THE CONTRACTOR SHALL OBTAIN AND PAY POR ALL PERMITS, L.IGINSIS, DOGUMUNI'$ AND SUIRVIGIS RELATED TO INSTALLATION OP THE WORK. 4. PRIOR TO S$UBMITTIN6 A PROPOSAL, THE CONTRACTOR SHALL VISIT THE SITE AND T'HOROUHLY INSPECT ALL UXISTINb CONDITIONS TO INSURE THAT TM WORK REPRESENTEZ7 ON THE DRAWN /MI AND IN WISE SP1GIPIGATI0N5 GAN OE INSTALLED Al INDICATED. I. DUCTWORK SHALL 11 PABRIGATIED AND ERIGTED IN AGGOIRDANG!' WITH ASHRAM AND L.ATUST *MAGNA ITANDA*DI. PROVIDE TURNING VANES IN ALL ELBOWS; AND MAMJAL VOLUIe DAMPERS IN ALL BRANCHES SPLIT - TER DAMPERS, AIR DSMALIZERS, EXTRACTORS, AND SIMILAR Device* WHEREVER NECESSARY TO PROPURLY BALANCE "ME SYSTEM AND PRODUCE A QUIET AND DRAPTL!SS OPERATION. 6. DUCTWORK SMALL BC 6AL.VANIZED SHEET METAL OP LOGIC I•ORMINO QUALITY WITH 2" THICK P I OER*LASO I NSULATI ON WITH POI L VAPOR BARRIER, ALL JOINTS AND SCAMS SHALL B! SEALED IN A MANNER TO PROVIDE A COMPLETE VAPORTIdtHT ENCLOSURE. 24 SAU6! UP TO 90 ", 22 SANE - 90" AND OVER. A : STANL, AND SPIRAL ROUND GALVANIZED SHEET METAL DUCTWORK. WITH 2" THICK FIDCR6LASS INSULATION WITH FOIL VAPOR BARRIER, ALL JOINTS AND SEAMS SHALL BE S!AL!D IN A MANNER TO PROVIDE A COMPLETE VAPORTI6NT ENCL0WRE. 24 6AUd! UP TO WO, 22 6AU6U -96" TO 50 ". I'IROT 19 FT. OP DUCT FROM EQUIPMENT SHALL BE LINED I" HEAVY DENSITY ACOUSTICAL INSULATION. 1. FLEXIBLE DUCTWORK SHALL BE TMCIRMAPLEX "M -KE" WITH ONE: INCH EXTER- NAL INSULATION FINISHED WITH A VAPOR BARRIER, U.L. AND 6 10A LISTED, SHALL 5! EQUIPPED WITH DAMPER-EXTRACTOR AT THE SHEl:TMIETAL DUCT AND CIRCULAR DOLLAR AT THE DIPPJSL'*, MECHANIGALJ.Y SECURED. b. •LEXIBLE DUCTWORK SHALL NOT EXCEED 4 PERT IN LENGTH; BENDS SHALL NOT RESTRICT THE INSIDE GROSS - SECTIONAL AREA OP THE DUCT; AND CONNECTION SHALL BE MAD! AS DIRECT AS POSSIBLE TO THE MAIN SUPPLY. 41. ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES PROVIDE ADEQUATE CLEARANCE POR ARGHITEGTUIIAL =slim, PROPER OPERATION AND SERVICE OP EQUIPMENT. 10. PROVIDE A READY-TO-USE SYSTEM WITH ALL WORK 6UARANT!ED IN WRI- THIN6 AGAINST DerT.GT1VE WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR PROM TURN OVER TO OMER. . CONDENSATE AND COOLER DRAINS: TYRE "M" HARD DRAWN COPPER FOR LINES I" AND SMALLER„ "DWV" HARD PRAWN COPPER FOR I -1/4" AND LAR6!*, GONPORMIN6 TO ASTM 5bb -12. retougroirr. COPPER PITTIN6S, DIRAINA6E TYPE FOR LINES I -1/4" AND LA*6!*. SOLO R WITH 50/50 SOLDER. 12. DUGTYVORK SHALL D! "FACTORY MADE" GLASS I 6ALVANIZSD SHEET METAL WITH IRON SUPPORTS SECURED TO OVERHEAD MEMBERS AT 5 DUCTWORK MATERIALS SHALL BE PER APPENDIX A, U.M.G. ; 11 19. PROVIDE AS PART OP THE MECHANICAL CONTRACT senvices or AN INDEPENDENT AIR /WATER BALANCINb CONTRACTOR CERTIFIED BY THE ASSOCIATED AIR BALANCE COUNCIL. SUBMIT 5 COPIES OF THE BALANCE REPORT TO A*GHITEGT /OWNER. 14. PROVIDE DUCT SMOKE DMT!GTOR5 IN SA DUCTS, TO OVER RIDE UNIT AND PROVIDE SHUTDOWN YVHEN UPON DETECTION OF SMOKE. HVAC NOTES ALL WORK TO DE AS PER THE L.L. 5P!GS, ALL LOCAL CODES, RULES AND R!6ULATIONS. ALL WORK TO BE AS PER ASH*A! AND SMACNA 6UIDELINRS. 2. ALL DUCT 51ZES SHOWN ARE CLEAR INSIDE. ALL DUCTS TO DE SHEET METAL DUCTS AS FER ASHRAE AND SMACNA SUIDELINCS. PROVIDE NECESSARY TURNING VANES, SPLITTEIR DAMPERS, VOLUME EXTRACTORS AND OTHER FEATURES NEEDED POOR A SMOOTH AND CONTROLLED FLOW OP AIR. 4. LOCATIONS SHOWN OF HVAC !EQUIPMENT AND DUCTS ARE SCHEMATIC ONLY. VERIFY STRUCTURAL DETAILS AND OTHER DETAILS THAT WILL AFFECT ROUTING AND PLACEMENT OP THESE COMPONENTS. II' MORE SUPPORTS ARM MOPED FOR HVAC EQUIPMENT, COORDINATE WITH THE ARCHITECT. . PROVIDE 'moPZR DUCT TRANSFORMATIONS FOR ACTUAL HVAC UNITS INSTALLED. ROOP PENETRATIONS, IP ANY, TO BE MADE AS PQR L.L. SPECS. VERIFY DETAILS WITH L.L.. PROVIDEE AND INSTALL THERMOSTATS AT LOCATIONS AS pIR!GTED BY THE ARCHITECT. . COORDINATE ACTUAL LOCATIONS OP DIFFUSERS, RESISTERS AND 6RILLCb WITH CEILING DETAILS AND OTHER FEATURES SUCH AS LI6ITINb FIXTURES ETC. THAT MAY AFFECT PLACEMENT OF TIC HVAC SYSTEM COMPONENTS. b. 6!NERAL CONTRACTOR SHALL SUPPLY ALL EQUIPMENT CONTROLS AND WIRING. COORDINATE WITH MALL REPRESENTATIVE POR INTTRLOCKIN6 WITH MALL CONTROL SYSTEM (AS REQUIRED). • • • • • • DUCTWORK SYMBOLS SINGLE P!lSCRIPTION DOUBLE ADM. =i3 7 l-I Jr • 46 DGb. TIC: USE AT BRANCH DUCTS ONLY • • RECTANGULAR DUCT ROUND DUCT • pUGT SPLIT 1f4/DAMPER: USE AT ELBOWS AND TEES: f•ROPORTION DUCT AREAS DY GPM'S 7 !� • GUlV!'D Q,ppW •MIN. RADIUS R: I.B WIDTM + • 40 aes. Mow ►wh, SIMILE RADIUS TuoaNS vm+es • 19..EXIOL! DUCT CONNECTION ,T PO FIRE DAMPER OD $ALANGIN6 DAMPER NW 0.13D. UNLESS NOTED 0THE RING!) NRNI TO PAWNS CONNECTION • SPIN ■IN •LCX DUCT TAKE - OPP W/DAMPE'R !A SUPPLY AIR ® 1X14 EXHAUST AIR z RA RETURN AIR 1E1 RBL RELIEF' AIR OSA OUTSIDE AIR • � g T THERMOSTAT MVSIORMI000 iAQp T THERMOSTAT X: UNIT OR ZONE NIMIMMIt • ExPIRES cs02,172 q r' 0 -. L . OM SK! NOME: These drawings and specifications are copy►Iphted one subloct o copyright prolsctlon Os on "archltec /ural gore under sec. 102 of the copyright act, 1 7 U.S.C. A. amended dse.mb.r 1900. The protection ,nci wlthout Ilm:tetlon. the ovMall form, orrongemem and composition of space.. and elements of the oesipn Under such protection. unauthorised use of these drawings and specificotlons mey result in cessation of construction. building seizurc and /or monolory Iiob�Iity. s V +0 1 +- SCALE: OMNIN x110 KT No.: n • 735 09- 0,-09 N.T.S. STAPP' tif ti 1 W '40 T� M2 A09046 13 of 1.1 .a ( 1 Ngill ' PRIOR TO CONSTRUCTION/ BID THE CONTRACTOR SHALL VISIT THIS SITE AND FIELD VERIFY THE EXISTING LOCATIONS AND SIZES OF M.UMBIN6 LINES AND FLOW DIRECTION. THE CONTRACTOR SMALL FIELD VERIFY ANY/ CONDITIONS WHICH MAY CONFLICT WITH THE DESIGN SHOWN ON mese PLANS. NOTIFY ARCHITECT. 5/4" 1/2" _ 1/2. HOT II COLD WATER SCHEMATIC wM,.+Mhwr.n..^�...+,..1 .. vw.i»- „�►.... -`... w+.+r•� T... ,+�. — 0. • .., ..wM.r ••• I" SL' PROVIDES ry 12X12 AGES PANEL.. ('TITIGAL) 1 / N.T.S. MARK NAG LAV EDP ..Mw+M.. W+w.. ••- •Wi...•..q • - .mrw•••..• •• .. IP !SCR I PT I ON HANDICAPPED WATER CLOSET LAVATORY WALL HUN* 0. SPIN PLOW FLOOR DRAIN TRAP PRIMMER INSTANTANEOUS WATT! HCATE'R CLCCTRIG DRINKING FOUNTAIN NOTE: I. PLUMBING CONTRACTOR SMALL VERIFY QUANTITY OF 1•LUMBINO FIXTURES REQUIRED FROM THE PLUMBINdr 1'L.ANS. 2. PLUMBING CONTRACTOR SMALL FURNISH AND INSTALL ALL 1'LUMDIN6 FIXTURES RES SHOWN ON THE rLUMBIN6 FLANS N4TMe LISTED OR UNLISTED ON THE FIXTURE SCHEDULE. r I XTURC !WOG I r I GATI ON. MANUPAGTUIIRE'R AND MODEL NUM5e "KOHLE"R" MI*NL.INE LIT! PRESSURE GLEAN *K- "AMERICAN STANDARD" *O5 .0 LUCIAN "J.*. SMITH" *2OOS -A "PPP INC." *''RIME RITE PR.400 "CH ONOMITC" Mb-50L "OASIS" MPPDAM (SINI6LE LEVEL) PLUMBING FIXTURE SCHEDULE rITTINO PLASM TANK 1.6OPP "RELIANT" $ IIINOLE LEVER PAUGET MAY EXTEND AS A WASTE OR VENT WALL PL.U66ED TEE NI/GLEANOUT FLOOR LINE I /b" G.I.BEND .BALANCE OP PIPING SAME AS CLEANOUT TO GRADE. WALL CLEANOUT DETAIL orb OM 5000 IA HEATING, CLEMENT AGGES►SORI REMARKS VITAS CHINA, Ill" WON ELON4ATED BOWL, PROVIDE SOLID PLASTIC. SEAT WITH OPEN PIRONT AND COVER PROVIDE WITH "MAMMON HANOI L.AV' GUARD *102 P .-TRAP AND WATER LINES INSULATION PER HANDICAP. IRE@MTS. AERATOR, GAST *RID STRAINER, 1 -1/4" OD. TAILPIECE, GHIR0N1U FINISH ROUND TOP NL/ TRApi PRIMER CONNECTION bb•F RISE FOR 0.5 GPM SCE ELECTRICAL D'RA$IN$$ 5/4" FOR VOLTAGE/PHASE WALLGO'VC1R i SCREW. PROVIDE $4 ACCESS PANEL. AND SHUT -OFF VALVE FRONT •USM ''AP ACTIVATION I-YEAR WARRANTY 1, 2" VTR 2 WASTE AND VENT SCHEMATIC r GOLD WATER 1 /2" 1/2" 9/b" 1/2" I I XTURC GONNEGTI ONG N.T.S. NOT WATER NIP 1/2" S /4" wALi MOUNTED LAVATORY (LAV) WASH 4" 2 d 2 " (WANTI T■ v!NT OF rIx"ry gs 2 I-I/2" I -1/2" GMIGA6O 442 -LK ANGLE STOP WITH LOCKSHIELD GAP. 2 2 2 2 2 TOTALS II" I XTUR! UN Tyr WATER F.U. WASTE 1 NAG.' ti I 2 So TOTALEAGN TOTAL 10 S. THE CONTRACTOR SMALL OBTAIN AND PAY FOR ALL PERMITS, 4 I 2 LIGENISES, DOCUMENTS AND SERVICES RELAT!D TO INSTALLATION OP THE WORD. i IS WATER HEATER DETAIL 6 12 S S - 5/4" CA FEED PROM CEILING f /r_ Ae o Vf 5. ALL WORK SHALL DE LOCATED TO AVOID GON PLIGT* WITH OTFiR TRADES AND PROVIDE ADEQUATE CLEARANCE FOR ARCHITECTURAL DESIGN, PROPER OPERATION AND SERVICE OF EQUIPMENT. 6. SOIL AND VENT PIPE SHALL DE CAST IRON SERVICE MIGHT DOLL 4 1 21 ARTITION STOP (TYP,) N.T.S. I. ALL WORK SHALL COMPLY WITH ALL APPLICABLE P!DURAL, STATE AND LOCAL CODES, LAMS, ACTS AND ALL AI1THORITIES NAVIN. JURISDICTION. 2. TWO GOIMPLITRD INSTALLATION SHALL BE IN ACCORDANCE WITH ALL LANDLORD'S IR UIR NTS; APPLICABLE INDUSTRY STANDARDS OP 0000 PRACTICE AND *AMY; Y; AND TN. MANUFACTURER'S STRICTIST IREGOMN+RNDATIONS POR EI'RIJIPMENT AND PRODUGT APPLICATION AND INSTALLATION. 4. PRIOR TO SUBMITTIN. A PROPOSAL, THE CONTRACTOR SMALL VISIT THE SITE AND THOROUGHLY INSPECT ALL EXISTING CONDITIONS TO INSURE THAT THE WOW IRLPRISIENTRD ON THE DRAWING* AND IN THESE SP!CIPIGATIONS CAN BE INSTALLED AS INDICATED. SPIGOT WITH SPLIT JOINTS. 1. COPPER PIPE SHALL BE USED FOR ALL WATER PIPING EXCEPT SERVICE PROM METER TO BUILDING. TYPE "L" HARD DRAWN COPPER SHALL BC USED FOR PIPE NOT SET UNDER CONCRETE. TYPE "K: SOFT COPPER SHALL Be USED FOR PIPING UNDER CONCRETE. FITTINGS SHALL BE NMROU6HT COPPER THI OUGNOUT. S. INSULATE MOT WATER LINES WITH 1/2" THICK "ARMAPLEX" INSULATION. II. SLOPE ALL SEER LINE'S AT 1/4" PER POET. UNLESS OTHERWISE NOTED. Pee !" IPTI ON SOIL WASTE LINE (iM) VENT LINE (V) GOLD WATER (CYO MOT WATER (H.W.) MOT MATER RETURN 6AS LINE TEMPERED WATLI R DRAIN LINE BUILDING SEWER FLOOR DRAIN (FD,) FLOOR SINK (F.5.) ROOF DRAIN MID) OVER FLOW DRAIN WALL CLEANOUT POINT OP CONNECTION SYMBOL �4— 0 S.G.O. 0 F.G.D. — , 61 ---- - - IC.W- 1 SYMBOL • • - 6 TW - D CJ a —1 AGO PLUMBING FLOOR PLAN PLUMBING GENERAL NOTES PLUMBING SYMBOL LIST NOTE: ONLY THOSE SYMBOLS SHOWN ON THE DRAWING APPLY I" GW SUPPLY LINE. GONNEGT TO EXISTING MAIN GA SUPPLY LINE • POWER RESTROOM LOCATION. FIELD VEIRIPY EXACT POINT OF CONNECTION. 4" WASTE LINE. CONNECT TO EXISTING MAIN 4" WASTE LINE AT FORMER RESTROOM LOCATION. FIELD VERIFY EXACT POINT OF CONNECTION. 1/4 "* I'-0" PESGRIPTI ON SHUT OFF VALVE (GAT!) CHECK VALVE UNION LUBRICATED PLUG VALVE HOSE SIBS (MS) BRANCH 'RISE OFF MAIN SURFACE CLEANOUT FLOOD! CLEANOUT GLOBE VALVE BALL VALVE 'ROOF DRAIN LEADER OVERFLOW DRAIN LEADER CONDENSATE DRAIN LINE INDUSTRIAL GOLD WATER 12)D3.0137 I ExPIRES aimodi • enraPillio r; v -• :r 2c `'3 Pilaw Cegra 2 735 £opYRIGIt1 NOTICE; These drawings end specifications on copyrignt.d and su4Ct to copyright Protection is on "architectural son ,' under see. 102 of IM copyright oct. 17 U.S.C. As amended dscsmbsr 1900. The protection inciud.s. without Iimitatlon, the overoii form, arrang.m.M and composition of spaces, and eism.nts of the design Under such protection, unauthorised use of th.s. drooings and spoclflcations may result In csssotion at cone$ructIon, building selsure. and /or mon.tory debility SCALE: OMAN IN: MOW : V +ay am. l+a• • • OS -O'-O9 9f1: I /4 "• I _0 STAPP AOSO P1 t of 1 0 i • I 33 35 36 m 41 42 43 44 45 46 V a 0 CD C) ELECTRICAL POWER PLAN — .,,.,, ,,,,0,,.,.. .. ..... i. ,.......,.<.....,....eq....lr.� .._,....,.. y.,.......u....: woo.. - . ._ ..,.�.n...�.w ........ -,a,.. ., J -BOX IN WALL NEXT TO #7 W/ 3/4' CONDUIT BETWEEN FOR STEREO VOLUME CONTROL DUPLEX OUTLET @ 88' A.F.F. FOR CD PLAYER. WIRE ON DEDICATED CIRCUIT W/ BASS MODULE DUPLEX. ROOF TOP UNITS (HP -1, 2 8. 3), 10.2 FLA, 480V, 3PH. PROVIDE WITH 30A, 3P, WP FUSED DISC. SWITCH WITH FRS -RK FUSES SIZED PER MANUFACTURER'S SPECIFICATIONS. VERIFY EXACT LOCATION WITH MECHANICAL CONTRACTOR. LOW VOLTAGE BELL WIRE IN 1/2' EMT CONDUIT BETWEEN PUSH BUTTON AT CASH /WRAP AREA AND ELECTRIC BUZZER AT STOCK ROOM DESK. PUSH BUTTON ( +48') FOR BUZZER AT CASH /WRAP COUNTER. TIMECLOCK FOR HVAC UNITS SET -BACK MODE. SEE PANEL FOR CIRCUIT ASSIGNMENT. TIME CLOCK FOR STORE FRONT SIGN. WALL MOUNTED NEAR ELECTRICAL PANEL. CEILING MOUNTED SMOKE DETECTOR. SEE FIRE ALARM RISER DIAGRAM, MANUAL PULL STATION AND COMBINATION HORN /STROBE. SEE FIRE ALARM RISER DIAGRAM. COMBINATION HORN /STROBE. SEE FIRE ALARM RISER DIAGRAM. FIRE ALARM CONTROL PANEL. SEE FIRE ALARM RISER DIAGRAM. ra 2' x 4' x 3/4' PLYWOOD TELEPHONE TERMINAL BOARD (T.T.B.), PROVIDE 1' E.C. TO TELCO POINT 3F CONNECTION. DUPLEX OUTLET FOR TELEPHONE MOUNTING BOARD. DUCT SMOKE DETECTOR MOUNTED AT SUPPLY AIR DUCT, INTERLOCK WITH HVAC UNITS TO PROVIDE SYSTEM SHUTDOWN IF SMOKE IS DETECTED. SEE FIRE ALARM RISER DIAGRAM. ROOF RECEPT FOR HVAC UNIT SERVICING. LOCATE WITHIN 25' OF UNITS 18 vie 27 3/4' EMT W/ PULL STRING TO T.T,B. FOR TELEPHONE CO. USE. KEYED POWER PLAN NOTES SAWCUT OR CORE EXISTING SLAB AND RUN (1) 3/4' E.C. UNDER SLAB FROM SENSORMATIC PAD LOCATION TO A STUB -OUT AT +13' -0' ON SIDE WALL NEAR (19) 19 DUPLEX OUTLET MOUNTED ABOVE SOFFIT FR SENSORMATIC SYSTEM POWER, VERIFY EXACT LOCATION WITH SYSTEM INSTALLER 20 RUN ALL ELECTRICAL, PHONES, AND LOW VOLTAGE SYSTEMS IN 3/4' RIGID CONDUITS TO BOTH SIDES OF CASH/ WRAP. RUN UNDER SLAB FOR STUB -UPS IN CASH/ WRAP COUNTER (BOTH SIDES) VERIFY METHOD OF SLAB PENETRATION (USUALLY CORING OR SAW CUTTING) COORDINATE WITH MALL AUTHORITIES PRIOR TO COMMENCE THIS WORK. PATCH AND REPAIR SLAB AS REQUIRED. COMPLY WITH MALL REGULATIONS. WHATEVER METHOD IS USED RUN EMT TO NEAREST ADJACENT WALL OR COLUMN. (VERIFY). LOW VOLTAGE BELL WIRE IN 1 /2' EMT CONDUIT BETWEEN PUSH BUTTON AT REAR ENTRANCE DOOR AND ELECTRIC BUZZER ABOVE CASH /WRAP COUNTER. 22 PUSH BUTTON MOUNTED IN CASH/ WRAP COUNTER CONNECTED TO BUZZER NEAR STOC ROOM DESK. VERIFY EXACT LOCATION W/ OWNER 23 J -BOX IN CASH/ WRAP FOR BUZZER POWER. (SEE ITEM NO. 24) VERIFY LOCATION WITH PAC -SUN. 24 ELECTRIC BUZZER IN CASH/ WRAP. CONNECT TO PUSH BUTTON LOCATED VERIFY LOCATION WITH PAC -SUN. C -) ELECTRIC BUZZER MOUNTED TO WALL AT 6' BELOW CEILING ABOVE STOCKROOM DESK. VERIFY EXACT LOCATION W/ OWNER. 26 J -BOX ON WALL AT 6' BELOW CEILING IN STOCK ROOM. 28 SWITCHED J -BOX FOR CASH / WRAP DISPLAY CASE LIGHTING. (ONE SWITCH FOR ALL DISPLAY CASES). MOUNT AS LOW AS POSSIBLE. 29 PULL BOXES ABOVE CEILING FOR CONNECTIONS TO CASH / WRAP STUB -UPS 30 QUADPLEX RECEPTACLE AT STOCKROOM/ D.M. OFFICE DESK 31 3/4' E.M.T. STUB -UP AT EACH REGISTER WELL W/ PULL STRING, MOUNTED ABOVE TRAP DOORS. (FOR FUTURE COMPUTER SYSTEM USE). 0 OUTLET IN CEILING FOR FUTURE SUSPENDED PAC -SUN CASH/ WRAP SIGN POWER. (US WHITE OUTLET AND COVER PLATE). m m NOTE: RUN 3/4' EMT CONDUIT UNDER SLAB TO BOTH SIDES OF CASH/ WRAP. (SEE NOTE #20). I I I • • a I I I TEL./ DATA BUZZER J -BOX FOR STOREFRONT SIGN POWER VERIFY EXACT. LOC IN FIELD DUPLEX CONVENIENCE OUTLET MOUNTED IN WALL AT +18' A.F.F. WHITE WITH WHITE COVER PLATE. 3/4' E.M.T. CONDUIT STUB -UP 6' ABOVE SLAB FOR PHONE, DATA AND BUZZER WIRE DUPLEX CONVENIENCE OUTLET MOUNTED IN CASH/ WRAP COUNTER. MOUNT AS LOW AS POSSIBLE. DEDICATED DUPLEX OUTLET, (HUBBELL OR EQUAL) WITH ISOLATED GROUND, MTD, IN CASH/ WRAP COUNTER. MOUNT BOX AS LOW AS POSSIBLE PHONE / COMPUTER JACK IN CASH/ WRAP COUNTER (RJ11). MOUNT BOX AS LOW AS POSSIBLE. J -BOX AT 88' A.F.F. FOR AUDIO SYSTEM W/ 1/2' EMT CONDUIT TO BOSE BASE UNIT (SEE SHT. E2) W/ PULL STRING. VERIFY ALL STEREO CONDUIT LOCATIONS W/ BOSE CORP. DEDICATED DUPLEX OUTLET, (HUBBELL OR EQUAL) WITH ISOLATED GROUND MOUNTED IN WALL AT +18' A.F.F. AT STOCK RO❑M DESK AND D.M. OFFICE. DUPLEX CONVENIENCE OUTLET MOUNTED IN SOFFIT, WHITE W/ WHITE COVER PLATE. G.F.I. CONVENIENCE OUTLET MOUNTED IN WALL AT + 48' AT TOILET ROOM, J -BOX FOR COMPLETE CONNECTION OF INSTA -HOT WATER HEATER. COORDINATE EXACT LOCATION WITH PLUMBING TRADE. TELEPHONE JACK AT +18' A.F.F. FOR COMPUTER SYSTEM CONNECTION AT STOCK ROOM DESK STORE TELEPHONE JACK AT +18' A.F AT STOCK ROOM DESK. EMT STUB -UP FOR ALL CASH/ WRAP SYSTEMS, (LE, OUTLETS, LIGHTING, PHONES, AND LOW VOLTAGE SYSTEMS). EXTEND TO THE DEVICES AS REQUIRED GANG ALL CONDUITS TOGETHER AND RUN TO THE DEVICES IN THE MOST INCONSPICUOUS MANNER POSSIBLE NEW PANEL 'H'. SEE ONE -LINE DIAGRAM. NEW PANEL 'L'. SEE ONE -LINE DIAGRAM. EXIST. RELOCATED 30 KVA TRANSFORMER MOUNTED ON TOILET ROOM PLATFORM. SEE SINGLE LINE DIAGRAM. I i i I I I (TYP.) 'L' -24,2 NOTE: ALL WIRING IN CEILING SPACE TO • BE IN EMT CONDUIT INCLUDING LOW VOLTAGE WIRING. SCALE: 1/4" _ I-O VIM OF SPEAKERS ` AUDIO EQUIPMENT TO BE BY THE 'BOSE CORP'. SEE BOSE DWGS. FOR EXACT PLACEMENT. 'L'-=i2 VIA CLOCK P eritir ca DATE: DIVI M1 N: MOW NW: •11) 735 CQPIAGMLSOTICL Those drawings and spocifkotions ars copyrighted and subject to copyright protection as an 'archfect„roi •err - under sec. 102 of the copyright act. 17 U.S.C. As emended docember 1910. The protection includes. without limitation. the overall form. arrangement and composition of spaces. and elements of the design Undo/ such protection. unauthorised use of these drawings and specifications mar resuN in cessation of construction. buliding leisure. and /or monetary Mobility OS -01-M I / =1' -0• STAFF V +No II MUM 4 14-- E1 17 0 I. p S a' .... :..... .... • L I V IC 3 N �.�• 1•1�+'AIIM�a!�1 "T'�. e. M— .1•11.M•r .i ..w' ELECTRICAL LIGHTING PLAN NL Y (TYP.) NOTE: ALL SALES LIGHTING SHALL BE CONTROLLED THRU THREE LIGHTING CONTACTORS (C- 1,C- 2,C -3) THE TEN. G.C. SHALL PROVIDE, INSTALL I WIRE THESE CONTACTORS. S. N 0 012 1.12 1.42 H2 H2 142 H2 142 1.42 H2 L- 23,25,27 HZ H2 ff 7 I f 19 I H -1,3 • ■.. TIM Al 3 "1"iliiir J AI f 3 H2 ■1■ NMI NMI ►bra■ uj 142 42 a FFit'42 Fe Ffrp D' NI HE H2 1 NL sus■ 13 23 610 M $42 NOTES 1. ALL WIRING IN CEILING SPACE ABOVE GRID SHALL BE IN RIGID CONDUIT THIS INCLUDES LOW VOLTAGE AND SPEAKER WIRING 2. SEE SHEET E3 FOR LIGHT FIXTURE ADA NOTES LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS SHALL HAVE OPERABLE PARTS OF THE CONTROLS LOCATED NO HIGHER THAN 48' AND NO LOWER THAN 15' ABOVE THE FLOOR. IF THE REACH IS OVER AN OBSTRUCTION BETWEEN 20' AND 25' IN DEPTH, THE MAXIMUM HEIGHT IS REDUCED TO 44' FOR FORWARD APPROACH OR 46' FOR SIDE APPROACH, PROVIDED THE OBSTRUCTION IS NO MORE THAN 24' IN DEPTH. OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25' FROM THE WALL BENEATH A CONTROL. w •' M '41 142 142 aiii 1 111■ L -3,5 TIMECLOCK WALE: I /4" : I.-0" KEYED NOTES `:./ EXIT (TYPICAL) LIGHT WITH SELF - CONTAINED BATTERY BACK -UP, CONNECT TO UNSWITCHED CIRCUIT. c: EMERGENCY LIGHT WITH SELF - CONTAINED BATTERY BACK -UP, CONNECT TO UNSWITCHED CIRCUIT. • • • L- 7,9,11 VIA TIMECLOCK NIGHTLIGHT (NL). CONNECT TO UNSWITCHED CIRCUIT. (TYPICAL) 4 2 -GANG J -BOX IN CEILING. FOR RCA AND SPEAKER WIRE JUNCTION PROVIDE 1/2' EMT CONDUIT WITH PULL STRING TO EACH SPEAKER LOCATION (431) VERIFY EXACT LOCATION WITH DRAWINGS AS PROVIDED BY BOSE CORPORATION. 0 2 -GANG J -BOX IN CEILING W/ 1/2' EMT CONDUIT W/ PULL STRING TO J -BOX AT BASS MODULE. VERIFY EXACT LOCATION WITH DRAWINGS AS PROVIDED BOSE CORP. PROVIDE 4x4 JUNCTION BOX FOR FEED THRU WIRING FOR FIXTURE TYPE 'A'. 'Dec) 5 care 2 0ti3 ftiter I SA Op e )9,4- t , 4 " 735 1�4PXfiJ fI. NOTICE; These drawings and specifications ore copyrights and subject to copyright protection as an • orchltocturei sorb` under sec. 102 of the copyright Oct. 17 u.S.C. As amended december 1090. The protection includes, without limitation. the overall form. orrangemens and composition of spaces. and elements of the design Under such protection. unauthorised use of these drawings and specifications may result in cessation of construction. building seizure. and /or monetary liability DATE: SCALE: MIMIC No.: In M a u 4•0 OS-01-09 SMEET: 1/4' 1'--O' STAFF 4k E2 e 00 ,0 Y /00 0 ELECTRICAL SYMBOLS LIST U.. ■WE F - -I FLUORESCENT STRIP LIGHT FIXTURE 1 °' -=a LIGHT TRACK OA WALL MOUNTED LIGHT FIXTURE �► EMERGENCY WALL LIGHTING UNIT WITH BATTERY PACK /0/ A.F.F. A.D.A. C. E.C. E.D.F. F.B.O. GFI GFCI GND ISO IG NL REC S.E.S. T.M.B. T.T.C. U.N,O. U/C WH WP XFMR RECESSED FLOURESCENT LIGHT FIXTURE 2x4 RECESSED FLOURESCENT FIXTURE q DUPLEX CONVENIENCE OUTLET It +18' A.F.F. U.N.O. DUPLEX CONVENIENCE OUTLET, SPLIT WIRED, ! +18' • A.F.F. U.N.O. m I. DUPLEX CONVENIENCE OUTLET a +42' A.F.F. U.N.O. FOURPLEX RECEPTACLE FLOOR OUTLET 0 SPECIAL OUTLET, VERIFY NEMA CONFIGURATION WITH EQUIPMENT JQ JUNCTION BOX, IN ACCESSIBLE LOCATION JUNCTION BOX IN ACCESSIBLE LOCATION WITH FLEXIBLE CONDUIT CONNECTION TO LIGHTING FIXTURE OR EQUIPMENT AS NOTED Iv TELEPHONE OUTLET (WITH 3/4' C. STUBBED ABOVE CEILING U.N.O.) e +18' A.F.F. ea TELEPHONE OUTLET, FLOOR MOUNTED (STUB 3/4' E.C. ABOVE ACCESSIBLE CEILING O DATA OUTLET AT +18' OR AS NOTED. STUB 3/4' E.C. INTO ACCESSIBLE CEILING SPACE. INDICATES HOMERUN TO PANELBOARD OR AS NOTED. HASH MARKS INDICATE NUMBER OF CONDUCTORS. NO HASH MARKS INDICATES 2 #12 AWG, 1 #12 BOND, 1/2' CONDUIT t C/B EF INDICATES CIRCUIT IN CONDUIT CONCEALED IN OR UNDER FLOOR CONSTRUCTION OR BELOW GRADE INDICATES CIRCUIT IN CONDUIT CONCEALED IN WALL OR CEILING SPACE PANELBOARD DISCONNECT SWITCH - SIZE AND FUSES PER MANUFACTURER'S RECOMMENDATIONS (WEATHER- PROOF WHERE OUTSIDE). THERMOSTAT OUTLET, +48' A.F.F. WITH 4S BOX AND PLASTER RING. MOTOR - SIZE AS INDICATED IN DRAWINGS SINGLE POLE SWITCH H.P. RATED MANUAL MOTOR STARTER WITH THERMAL OVERLOAD PROTECTION. (WEATHERPROOF WHERE OUTSIDE) SMOKE DETECTOR (MATCH EXISTING) DUCT SMOKE DETECTOR (MATCH EXISTING) TIMECLOCK 'INTERMATIC, T7401B. ABOVE FINISHED FLOOR AMERICAN WITH DISABILITIES ACT CONDUIT CIRCUIT BREAKER EMPTY CONDUIT WITH PULL CORD. ELECTRICAL DRINKING FOUNTAIN (VERIFY ROUGH -IN REQUIREMENTS) EXHAUST FAN FURNISHED BY OTHERS, INSTALLED BY ELECTRICAL CONTRACTOR GROUND FAULT INTERRUPTER GROUND FAULT CIRCUIT - INTERRUPTER GROUND ISOLATED ISOLATED GROUND NIGHT LIGHT RECEPTACLE SERVICE ENTRANCE SECTION TELEPHONE MOUNTING BOARD. 4'Wx8'Hx3 /4'D PLYWOOD WITH •6 CU. GROUND WIRE TO APPROVED GROUND. TELEPHONE TERMINAL CABINET. 30'Wx36'Hx6'D 16 GA. WEATHERPROOF E/W HINGED LOCKABLE COVER 5/8' PLYWOOD BACKBOARD, PROVIDE A #6 CU. GROUND WIRE TO APPROVED BUILDING GROUND. UNLESS NOTED OTHERWISE UNDER COUNTER WATER HEATER WEATHERPROOF (RAINTIGHT) TRANSFORMER r a GENERAL ELECTRICAL NOTES 1. CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS UNDER WHICH HE IS TO PERFORM HIS WORK. NO ALLOWANCE WILL BE MADE FOR FAILURE TO COMPLY. 2, ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE 1993 (OR LATEST ADOPTED) NATIONAL ELECTRICAL CODE AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. 3. VERIFY EXACT LOCATION, MOUNTING HEIGHT AND ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT PROVIDED BY OTHERS (INCLUDING HVAC EQUIPMENT) PRIOR TO ROUGH -IN AND PROVIDE ALL REQUIRED FUSIBLE SWITCHES, TRANSFORMERS, STARTERS NECESSARY FOR PROPER OPERATION OF EQUIPMENT. 4. DUPLEX RECEPTACLES MOUNTED WITHIN 6 FT. OF SINK 5. ALL WIRING SHALL BE COPPER, THHN /THWN OR XHHW INSULATED IN CONDUIT. MINIMUM CONDUIT SIZE TO BE 1/2'. PROVIDE INSULATED COPPER BOND WIRE ON ALL 6. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF LIGHTING FIXTURES. VERIFY CEILING TYPES AND PROVIDE NECESSARY MOUNTING HARDWARE TO ACCOMMODATE LIGHT FIXTURES USED. PROVIDE SLOPE CEILING ADAPTERS WHERE REQUIRED. 7. ADDITIONAL EXIT SIGNS AND EMERGENCY LIGHTING MAY BE REQUIRED. ADDITIONAL FIXTURES SHALL BE LOCATED AS DIRECTED BY THE LOCAL BUILDING LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS SHALL HAVE OPERABLE PARTS OF THE CONTROLS LOCATED NO HIGHER THAN 48' AND NO LOWER THAN 15' ABOVE THE FLOOR. IF THE REACH IS OVER AN OBSTRUCTION BETWEEN 20' AND 25' IN DEPTH, THE MAXIMUM HEIGHT IS REDUCED TO 44' FOR FORWARD APPROACH OR 46' FOR SIDE APPROACH, PROVIDED THE OBSTRUCTION IS NO MORE THAN 24' IN DEPTH. OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25' FROM THE WALL BENEATH A CONTRO' -.. 120V, 1PH KEYED NOTES: O 2 #12 THWN CU, 1 #12 CU. GROUND, 1/2' EMT OR FLEX METALLIC CONDUIT. 1) VERIFY THAT THE #12 CU. GROUND WIRE IS CONTINUOUS AND IS BONDED TO THE PANELBOARD GROUND BUS. 2) MEASURE THE VOLTAGE FROM NEUTRAL WIRE TO GROUND WIRE. VOLTAGE SHOULD BE ZERO VOLTS. ANY OTHER READING INDICATES IMPROPER GROUNDING AND IS NOT AN ACCEPTABLE INSTALLATION. 0 TRANSFORMER, ENCLOSURE AND METALLIC PARTS OF THE SIGN TO BE GROUNDED PER N.E.C. 600 -7. 0 3 SECONDARY CONDUCTOR IN CONDUIT, BOND PER N.E.C. 60 -7. 120V, 1PH i 1 P • I ON ADA NOTES ELECTRICAL DETALS LEON TRANSFORMER GROUNDING DETAIL WmUIG DIAGRAM - LIGFITIN((i CONTACTOR (MECH. HELD) KEYED NOTES: O 20A. CONTACTS, SEE ONE -LINE DIAGRAM FOR NO. OF POLES REQUIRED. MECHANICALLY HELD LIGHTING CONTACTOR IN NEMA 1 ENCLOSURE. O MOMENTARY CONTACT, SINGLE POLE, DOUBLE THROW, CENTER OFF WALL SWITCH, LEVITON CAT. NO, 5657 OR APPROVED EQUAL. U.L. 2161 LISTED NEON TRANSFORMER LINE LOAD N.T.S. tr TC, le C2 C3 C2 C3 C2 C3 C2 C3 .. C1 • • V PAIIUOARD ScIDtLI #12'S ., *1 # 12'S — TRACK 16' — TRACK 16' TRACK 16' TRACK 14' — TRACK 16' — TRACK 16' — TRACK 16' — TRACK 8' /SALES Ne SPACE RECEPT. — SHOWINDOW TOTAL LOAD PER PHASE 277/480 VOLT$ SUE V — ROOF USE FOR AREA SERVED LIGHTS — SALES — NL/EM/EXIT SPARE WATER HEATER WATER HEATER TOTAL LOA.D PER PHASE - SHOWINDOW • CONTINUOUS LOAD TAKEN AT 125% • CIRCUIT BREAKER WITH LOCK -ON DEVICE. TC THRU TIMECLOCK C2 LIGHTING CONTACTOR 2 C3 LIGHTING CONTACTOR 3 2 2 1 • CONTINUOUS LOAD TAKEN AT 125% • CIRCUIT BREAKER WITH LOCK -ON DEVICE O LARGEST MOTOR TAKEN AT 125% PER N.E.C. ❑ CIRCUIT BREAKER WITH LOCKABLE DEVICE. Cl LIGHTING CONTACTOR NNW VA + (4I•'[i • PANEL SCHEDULES • : X 4 { 28 11 ievaos VOLTS I ..._ mow j 4 woo soup NEUTRAL SURFACE I411ClU '1 a 10 III QA MCB * , BOLT TYPE. U Al - AIWA �` C: C L + > j ai ( Iwit) �. _.. U ANIO 'OR AREA � : nel; LIGHTS — STOCKRM/TOILET — STOREFRONT 2y: f I . �! 1 CASH REGISTER *12'S >t _ ,,,, i28 I ,,,,, 1 li8 • I CASH WRAP /BUZZER RECEPTS - STEREO SYSTEM - SHOW WINDOW f... — SALES : 88 • n L .. 3 i PACSUN SIGN l Y.. SIGN _ ............._.... , _.,.... _ n RECEPTS - STOCKRM/TOILET 'Iii _ e 4 * - STOCKRM DESK ....T r.. MNGR'S DESK * .1'48 , _ - WINDOW . ".a 300 9879 PANELBOARD SCHEDULE 3 PI BE 4 MAI NOON.- SURFACE LOADS NO A 22485 —188 180 500 9636 9956 ig38 n 1 4 3331 � 22367 79 AMPi C 88 21687 SR it8 42 „ DUCT SMOKE DETECTOR . 14,000 ABC, ailtAlr O•INTED 100A MCB SANS BOLT -ON TYPE ;.. :. USE -OR AREA SERVED SO 2! 0 .... (NEW) tlrb Pio - MN J .: LOAD CALCULATIONS L,IQHTS AT 125% 218711 VA SIGN AT 128% . 1000 VA OUTLETS, 118C. POWER AT 100% 10000 VA REMAINDER AT 50% . 720 VA WATER HEATER AT 10011 . 0000 VA IWAC HP-1 AT 125% 999$ VA HP-2 AT 100% 11475 VA 1P-3 AT 100% 8475 VA DUCT SMOKE DETECTOR 000 VA TOTAL LOAD 45049 VA ANTI—THEFT SYSTEM E DISPLAY CASE LIGHTING j RECEPT - E.D.F. - TMB .,.._. _ :—REF AC TIMECLOCK FIRE ALARM CONROL PANEL 9956 30 KVA TRANSFORMER (EXIST.) HP -1 HP -2 (NEW) HP -3 (NEW) 22485 10,000 rac. WILMER 11011104 9 As 83 AmPS 0 A 81 SIZE *6'S #12'S C3 •n • • • AUDIO /VISUAL STATIONS REFER TO PLANS FOR QUANTITY. MANUAL PULL STATIONS. REFER TO PLANS FOR QUANTITY. 3/4' C. TO TMB. WITH AUTO DIALER TO MONITORING STATION AS REQ'D. F.A.C.P #6 CU. GROUND DUCT DETECTORS. S FLOW SWITCH - BY OTHERS. S TAMPER SWITCH - BY OTHERS. S DUCT SMOKE DETECTORS, SEE PLANS FOR QUANTITY. �►. 120V LANDLORD'S FAAP I FIRE ALARM PANEL FIRE ALARM RISER DIAGRAM NTS NOTES: 1. ELECTRICAL CONTRACTOR SHALL CONFIRM COMPLETE FIRE ALARM SYSTEM REQUIREMENTS WITH FIRE MARSHALL OR ANY LOCAL AGENCIES HAVING JURISDICTIONS. A COMPLETE OPERATIONAL AND APPROVED FIRE ALARM SYSTEM FOR THIS PROJECT IS DEEMED PART OF THE ELEC. CONTRACTOR'S CONTRACT. THIS SYSTEM SHALL BE COMPATIBLE WITH THE MALL FIRE ALARM SYSTEM. ALL CONNECTIONS, OR 2. MODIFICATIONS TO LANDLORD'S FIRE ALARM SYSTEM ARE TO BE COMPLETED BY LANDLORD'S AUTHORIZED CONTRACTOR. CONTACT MALL MANAGEMENT FOR DETAILS. MAN( SYMBOL A Al S kte C • D V E c17 o H ■.r;■ I2 K L M N X X1 Y PIMP. low PLAT Ime Wall. / otscl11PTION _p. LAWS LITHONIA IU3G-D22-340-BX55-335 - 120V. OR 277V RECESSED PARAMAX FLOURESCENT FIXTURE W/ (1) E - 340 - 9 CELL LOUVER A (2) 40TBX H.E. WILLIAMS SU4- D22- 340- BXSS -33S SURFACE MOUNTED PARAMAX FLOURESCENT FIXTURE WITH 9 CELL LOUVER - VERIFY 120 OR 277 V A (2) 40T BX 'STONCO' VWXL1IGC VAPORTITE WALL MTD. FIXTURE (NO CAGE) 'JUNO' TESL. •IM4♦AL1 We LAMP HOU** bM T - lSSOL TRACK MOUNT TRANSPOOMPIt 'JUNO' *T437 - TRACK FIXTURE 'JUNG' #T437 -BL FIXTURE W/ T46 BL CLAMP -ON ON ADAPTER (2) 'STONCO' 40L HEAVY DUTY FLOOD LAMP HOLDER - NATURAL ALUMINUM. ON 2 -LAMP POD (I) S VLVANIA A DuI.UX 30P COMP. '"L. FIX. A (1) 50W MR -16 / NFL / 25T A (1) 60 PAR 38 HIR /NSP /120V A (1) 60 PAR 38 HIR /NSP /120V A (2) 60 PAR 38 HIR /NSP /120V 'JUNO' #TC2- 25B -WH RECESSED DOWNLIGHT FIXTURE '.xJNO' MT5X -!!1. COMPACT FLUORESCENT 5IAX FIXTURE 1^I/ ELECTRONIC BALLAST ON wT- 46-DL. M4ONO!'OINT CANON'. PROVIDE P4/ *OLIO BLACK L.OUWl* ACCESSORY. A (1) 60 PAR 38 HIR FL 120V A (2) 39W HIGH LUMEN C.F. 120V HPF 'JUNO L COMPACT FLUORESCENT a AX FIXTURE IN/ *BUD BLACK LOWER AND ELEC. BALLAST. W/ T-440 EL CLAMP ON ADAPTER 1 COMPACT FLUORESCENT BIAX FIXTURE W/ SOLID BLACK. LOUWSR AND ELEC. BALLAST. A (2) 39W HIGH LUMEN C.F. 120V HPF A (2) 39W HIGH LUMEN C.F. 120V HPF ELP 240 BXWW- AK- EB -120V RECESSED FLUOR- ESCENT WALL WASHER. IN 9 -1/8' x 48 -1/2' R.O. A (2) F40 HIGH LUMEN COMPACT FLUORESCENT ELP 140 BXWW- AK- EB -120V RECESSED FLUOR- ESCENT WALL WASHER. IN 9 -1/8' x 24 -1/2' R.O. A (1) F40 HIGH LUMEN COMPACT FLUORESCENT 'JUNO' LIGHT TRACK (BLACK) #T2BL, T4BL OR T8BL SECTIONS PER PLAN, SUPPLY #T23BL, T21BL STR. CONNS. AND LIVE ENDS AS REQ. A LITHONIA #C240 -120 V OR 120 -ES, 2 TUBE, SURFACE MOUNTED FLOURESCENT FIXTURE. A (I) P92 TO I2OV. EMERGI -LITE *ECLXN-4-G ILLUM. EXIT SIGN W/ SELF POWERED NI -CD BATTERY A INCLUDED I2O/ZTTV EMERGI -LITE • LXN- 1- RC -C -U UNIVERSAL MOUNT EDGE LIT ILLUMINATED EXIT SIGN INSTALL AS PER PLAN. A INCLUDED 1201211Y EMERGI -LITE •ECX -2 (HD) 6 VOLT SURFACE A INCLUDED MTD. EMERGENCY LIGHT WITH LC BATT. 120/277V BACK -UP I REs p o p memy co A FURNISHED BY PACIFIC SUNWEAR, INSTALLED BY TEN. G.C. B FURNISHED AND INSTALLED BY TEN. G.C. i NOTE: IN ORDER TO INSURE PROMPT DELIVERY OF THE LIGHT FIXTURES, PACIFIC SUNWEAR HAS PRE - ORDERED ALL FIXTURES SPECIFIED. THE ELECTRICAL CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS - EXCLUDING OWNER SUPPLIED UNITS - AND MUST MAKE ARRANGEMENTS TO RECEIVE THE FIXTURE SHIPMENT AND INSPECT AND FILE ALL CLAIMS FOR DAMAGE AGAINST THE COMMON CARRIER. DAMAGED FIXTURES, SHORTAGES OR WRONG VOLTAGE SHOULD BE PROMPTLY REPORTED TO PACIFIC SUNWEAR ATTN. KIM BENNETT, CONSTRUCTION MANAGER1 (714) 414 - 4038, WITHIN 24 HRS. OF INSPECTION OF SHIPMENT. THEREAFTER, THE ELEC. CONTRACTOR IS RESPONSIBLE TO REPLACE ANY MISSING PARTS AT HIS EXPENSE. LANDLORD SPACE TENANT SPACE 'H' -1,3 MOMENTARY LIGHTING - CONTACTOR SWITCHES. SEE SHEET E2 FOR LOCATION. (TYP.) MECHANICALLY HELD LIGHTING CONTACTOR, (TYP. OF 4) 20A, 6P, 120V COIL IN NEMA 1 ENCL. SIZE NO. OF POLES AS REQUIRED. REFER TO WIRING DIAGRAM THIS SHEET. LIGHT FIXTURE SCHEDULE SINGLE LINE DIAGRAM NEW 4 #1 CU. (XHHW), 1 #6 CU. GRD, 1 1 /2'C. m S$ � LANDLORD'S SERVICE ENTRANCE SECTION ‘4 ,- 277/480V, 30, 4W r EXIST. METER \ T 1 (FIELD VERIFY) NEW 100A, 3P •IM.. - r _ _ PANEL 'H' (NEW) NEW 4 *1 CU. (XHHW), 1 #6 CU. GRD, 1 1/2'C. NEW 100A, LPS -RK FUSES NEW 100A 3P MCB 1D3tiy NEW 50A 3P CB iv Y EXIST. r., TRANSFORMER 30 KVA 480V- 120/208V, 30, 4W. PANEL 'L' (NEW) Or 'L'- 3,5,7,9,11,12 N '.■•4■ 'L'- 10,15,19,23,27 '.- 'L'- 13,17,21,25 NEW 3 #6 CU. (XHHW), 1 #10 CU GROUND, 1'C. EXIST GRD. TO BLDG. STEEL NEW 100A 3P MCB —NEW 7 DAY DIAL TIME SWITCH, 4 -POLE SINGLE THROW. INTERMATIC, CAT. *T74013. 40A, 4PST, NEMA 1 ENCL. . THE ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. ib ,„,gs ge Cosa g go a a COPYRIGHT NOTICE; Thos41 drewirtgs and specifications ore copyrighted and subJsct to copyr$gM pr0MeNOn es on "erchItecturol won" undor sec. 102 of the copyright oct. 17 u.S.C. As amended dwcsmbsr 1190. The protection inciudss, without Ilm $i/ien. the overall form. orrongornent and composition of woos, and elements of the design. Undo• such protachow. unauthorized use of those drawings and spoelfioatiens mey rosus In cossot+on of construction. building *More. and /or monNory �iobiIity. v, iess DATE: . SCMf: DRAM r11: MIOIEC'T No.: 735 • • NONE STAFF E3 AO.O 19 Of 1 a r i r DOUBLE RIVET BEAM SINGLE RIVET BEAM LOW PROFILE DOUBLE RIVET BEAM GENERAL CONFIGURATION FASTEN TO UPRIGHT W/ #12 X 3/8" TEK SCREWS OR EQUAL RELIEF HOLE FOR DRB RIVET HEAD ANGLE POST DOUBLE FOOT PLATE FRONT VIEW \ l` .290" KEY SLOT DETAIL 1 REQ'D PER BASE PLATE KEY SLOT DETAIL 5/16 "O RELIEF HOLE FOR DRB RIVET HEAD ANCHOR ]LIGHT DUTY STORAGE FIXTURE ELEVATIONS 2A SINGLE FOOT PLATE FRONT VIEW TOP VIEW � 1 11/16" STATIONARY UNITS NOTES: REV. DATE BY FRONT VIEW SIDE VIEW DESCRIPTION REVISED LOADING LIGHT DUTY STORAGE FIXTURE DETAILS 1. STORAGE RACK DESIGNED PER CHAPTER 22, DIVISION X OF THE 1997 UBC, SEISMIC ZONE 4, Na = 1. 2. STORAGE CAPACITY: 115# PER LEVEL 3. ASTM A570 FOR SHAPE Fy = 36,000 PSI GRADE 36 4. ALL BOLTS A307 (UNLESS NOTED) 5. ANCHORS HILTI KW1K BOLT II OR APPROVED EQUAL ICB° #4627. 6. CONCRETE 4" THICK x 2,000 PSI 7. SOIL BEARING PRESSURE 1,000 PSF 8. SPECIAL INSPECTION IS NOT REQUIRED FOR ANCHOR INSTALLATION CALIFORNIA LAST REV. BY: D.J.0 DATE: 611 i 2 CONTRACTORS LICENSE NO. x;74 APRV'D eY:$,AL E. FA "1 EE SCALE: N.T.S. -'� SEIZMIC SEIZMIC MATERIAL HANDUNG ENGINEERING 101 Atlantic Sheet EST. 1965 Pomona, CA 217011 Tel. (909) 9650909 • MO 969 -0961 DRAVVP DATE: 2/2102 02 -0207A 1""1"."' 10110/1"POOP"IPNWPOPPAN I. 3 • aw ( i *.Piewou'reimmwommi"miteraieswwwww. ler we mu wirivenmsai ovol Po mil It 41 1W 0 1 • sdo 3 --•- / 7 • "'�11A11A+ +Mw` END STOP MOBILE TRACK ANTI -TIP RAIL ROLL PINS -t-- 36" & a8" t 36"848"--t POST OF SHELVING UNIT (SHELVING UNIT NOT SHOWN) SEE DRAWING NO. 02-0207A FOR DETAILS FRONT VIEW GENERAL CONFIGURATION MOBIL CARRIAGE SPLICE DETAIL LIGHT DUTY STORAGE FIXTURE ELEVATIONS ANTI -TIP ARM MOVABLE UNITS FRONT VIEW USE EVERY 24" STAGGERED 2 MIN. EMBDMNT 4A ANTI -TIP TRACK ANCHOR SIDE VIEW ANITTIP • TRACK ANTI -TIP TRACK ANCHOR VIEW "A -A" ANTI -TIP ARM ANTI -TIP TRACK ANTI -TIP ARM MOBILE CARRIAGE TRACK ANCHOR 1 5/8" 2 1M6' REV. DATE NOTES' 1. STORAGE RACK DESIGNED PER CHAPTER 22, DIVISION X OF THE 1997 UBC, SEISMIC ZONE 4, Na =1 2. ASTM A570 FOR SHAPE Fy = 33,000 PSI GRADE 33 3. ALL BOLTS A307 (UNLESS NOTED) 4. ANCHORS HILTI KVVIK BOLT II OR APPROVED EQUAL IC80 #4627. 5. CONCRETE 4" THICK x 2,000 PSI 6. SOIL BEARING PRESSURE 1,000 PSF 7. SPECIAL INSPECTION IS NOT REQUIRED FOR ANCHOR INSTALLATION CALIFORNIA CONTRACTORS LICENSE NO. 085374 DESCRIPTION REVISED REF. TO ANTI -TIP TRACK DRAWN BY: MOVABLE BASE DETAILS A00"p° PACIFIC SUNWEAR ZONE 4 DATE: 9/10/03 APRYD BY:SAL E. FATEMSCALE: N.T.S. DRAWING NUMBER 02 -0Z076 r"S::*0 door 39