HomeMy WebLinkAboutPermit D03-146 - PERFECT FIT / MCDONALD - STORAGE RACKSPERFECT FIT MCDONALD INC. 18249 OLYMPIC AV S D03 -146 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Tenant: Name: PERFECT FIT - MCDONALD INC. Address: 18249 OLYMPIC AV S, TUKWILA, WA DESCRIPTION OF WORK: INSTALLATION OF RACKING Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Water Meter: doc: Devperm DEVELOPMENT PERMIT Parcel No.: 7888900152 Permit Number: D03-146 w Address: 18249 OLYMPIC AV S TUKW Issue Date: 05/22/2003 W Suite No: Permit Expires On: 11/18/2003 JU O 0 co o co al J H U) LL w Owner: Q Name: CAMPBELL JAMES ESTATE Phone: LL J ¢ Address: 1001 KAMOKILA BLVD, KAPOLEI HI co a ' w Contact Person: Z , Name: JAMES H. RIDDY Phone: 206 682 -7161 z O Address: 18249 OLYMPIC AV S, TUKWILA, WA w I— • w Contractor: j a Name: OWNER AFFIDAVIT ON FILE Phone: O N Address: , 0 H Contractor License No: Expiration Date: w iii O N Value of Construction: $ $0.00 Fees Collected: $211.16 z Type of Fire Protection: SPRINKLERS /AFA Uniform Building Code Edition: 1997 Type of Construction: RACKS Occupancy per UBC: 0025 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Profit: N Non - Profit: N Water Main Extension: N Private: N Public: N N ** Continued Next Page ** D03 -146 Printed: 05 -22 -2003 Permit Center Authorized Signature: L , I hereby certify that I have ordinances governing this The granting of this permi regulating construction or Signature: Print Name: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 read and examined this permit and know the same to be true and correct. All provisions of law and work will be complied with, whether specified herein or not. t does not presume to give authority to violate or cancel the provisions of any other state or local laws the performance of work. I am authorized to sign and obtain this development permit. Date: Date: 6 22 b3 Z —Z -C13 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D03 -146 Printed: 05 -22 -2003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 7888900152 Address: 18249 OLYMPIC AV S TUKW Suite No: Tenant: PERFECT FIT - MCDONALD INC. PERMIT CONDITIONS Permit Number: D03 -146 Status: ISSUED Applied Date: 05/14/2003 Issue Date: 05/22/2003 1: * **BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 4: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 5: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 6: ** *FIRE DEPARTMENT CONDITIONS * ** 7: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 8: In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 13) 9: Maintain minimum 6" longitudinal flue space between back to back racks. (NFPA 13) 10: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 5.5.3.1) 11: Refrain from blocking sprinkler coverage with shelving. NFPA standard #13 states that any shelving or decks in excess of 4 feet in width will require installation of sprinklers thereunder. 12: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 13: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 14: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Conditions D03 -146 Printed: 05 -22 -2003 City of Tukwila Department of Community Development 1 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any regulating construction or the performance of work. Signature: Print Name: doc: Conditions D03 -146 of law and ordinances other work or local laws Printed: 05 -22 -2003 SITE LOCATION Site Address: Tenant Name: Property Owners Name: Mailing Address: CONTACT Name: Mailing Address: E -Mail Address: GENERAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contact Person: E -Mail Address: Contact Person: E -Mail Address: \applications\permit application (3.2003) 3 /2003 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** I LLi g C/l-•, n�� f�-v e S 'Y cfu.. C-r* vs C 1sct- -A Kr at 1+. - emsa .� 1 rc� -LiS Gl-•t tit, y •: ilrvt C S Qvvt)vc I £'L1 t- 4-MDt; Pn. Luci t'age 1 • Building.Per itNo Mechanical'Permit ' Public', Work Perm >No. Project No King Co Assessor's Tax No.: Suite Number: New Tenant: City City ARCHITECT OF RECORD` =_All plans must be wet stamped by Architect of Record ENGINEER' OF RECORD .= All plans must be wet stamped by Engineer of Record (For:ofce'use only) . Day Telephone: L b - Gat -1 lbi \v k Iki f( City State Fax Number: --f1,- ' & , �� -���s� Floor: .... Yes 0..No State State State Zip Zip Zip Zip 74 �M1 • Day Telephone: Z-- 2-t -3,y.13tc. Fax Number: Z- c (, - Sla" ikk 3 Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Company Name: Mailing Address: City Day Telephone: Fax Number: Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: :;r.u'Li,•.....-- .:i.zu;;:wi�. t.:' s >3:.i�..,::g>'x�.tb¢ „`. "y�,w�:. ... BUILDING PERMIT INFORM A TION - . 206 - 431 -3670 Valuation of Project (contractor's bid price): $ Goo Existing Building Valuation: $ Scope of Work (please provide detailed information): "%lLIS f -G Will there be new rack storage? C] ..Yes ❑.. No If "yes ", see Handout No. for requirements. PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Provide All Building Areas in Square Footage Below Will there be a change in use? ❑ ....Yes ..No If "yes ", explain: Compact: Handicap: FIRE PROTECTION/HAZARDOUS MATERIALS: g .. Sprinklers ..Automatic Fire Alarm D..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ..No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets, lapplicationa\permit application (3.2003) 3/2003 Page 2 Nut.z�µ4_wu..it�w'rt.n:,; �4o,S ✓''• = %l Existing Interior Remodel Addition to Existing Structure New Type of Construction per UBC Type of Occupancy per UBC 1'1 Floor -.2_9,DUU %1745- 2h° Floor 3 Floor Floors . , ., thru Basement Accessory Structure *. Attached Garage Detached Garage Attached Carport .. Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORM A TION - . 206 - 431 -3670 Valuation of Project (contractor's bid price): $ Goo Existing Building Valuation: $ Scope of Work (please provide detailed information): "%lLIS f -G Will there be new rack storage? C] ..Yes ❑.. No If "yes ", see Handout No. for requirements. PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Provide All Building Areas in Square Footage Below Will there be a change in use? ❑ ....Yes ..No If "yes ", explain: Compact: Handicap: FIRE PROTECTION/HAZARDOUS MATERIALS: g .. Sprinklers ..Automatic Fire Alarm D..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ..No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets, lapplicationa\permit application (3.2003) 3/2003 Page 2 Nut.z�µ4_wu..it�w'rt.n:,; �4o,S ✓''• = %l PUBLIC WORKS .PERMIT INF 2MATION - 206- 433 -0179 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ... ValVue ❑ .. Renton ❑ ...Seattle ❑ ...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitary Side Sewer ❑...Cap or Remove Utilities ❑...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size.. ❑...Water Only Meter Size ❑...Sewer Main Extension Public _ ❑ ...Water Main Extension Public _ Water Meter Refund/Billing: Name: Mailing Address: \applications \permit application (3-2003) 3/2003 Please refer to Public Works Bulletin #1 for fees and estimate sheet. cubic yards cubic yards „ „ H Call before you Dig: 1- 800 -424 -5555 ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line „ „ „ WO# WO# WO# Private Private FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Mailing Address: ❑ .. Highline ❑ ...Renton ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ .. Maintenance Agreement(s) ❑...Hold Harmless ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage Number of Public Fire Hydrant(s) Page 3 ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size Day Telephone: City City State State Zip Day Telephone: Zip • W L Unit Type: Qty Unit Type: Qty Unit Type: Qty . Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended /Wall /Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ 1IP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm /Ind MECHANICAL PERMIT INFORMATION — 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: Contact Person: E -Mail Address: Contractor Registration Number: * *An original or notarized copy of current Washington State Contractor Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Expiration Date: License must be presented at the time of permit issuance ** Use: Residential: New .... D Replacement ....0 Commercial: New ....0 Replacement ....0 Fuel Type: Electric (J Gas ....❑ Other: Indicate type of mechanical work being installed and the quantity below: PERMIT: APPLICATION NOTES' - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED Tills APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: \ Print Name: Mailing Address: \ F5 Z _4 QL- ts , ; t Signature: \applications\permit application (3.2003) 3/2003 Page 4 Date: 4 C - t 4 Day Telephone: "I`tett-tAA 1.4 City State Zip Date Application Accepted: Q -3 I Date Application Expires: Staff Initials: caa w Ir e Parcel No.: 7888900152 Permit Number: D03-146 - v Address: 18249 OLYMPIC AV S TUKW Status: PENDING v o Suite No: Applied Date: 05/14/2003 w w Applicant: PERFECT FIT - MCDONALD INC. Issue Date: -J H U) u_ WO 2 Receipt No.: R03 -00594 Payment Amount: 211.16 g Q co Initials: SKS Payment Date: 05/14/2003 11:37 AM = w I- User ID: 1165 Balance: $0.00 _ Z I.- I— O Z I- w • w D • 0 O — C1 I- wW Type Method Description Amount I- � O H Payment Check 4653 211.16 1:U U � H-= O I- Payee: TRANSACTION LIST: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERFECT FIT BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/345.830 000/386.904 RECEIPT 125.25 81.41 4.50 Total: 211.16 8672 05/15 9716 TOTAL. 211.16 Printed: 05 -14 -2003 Z r ect: C 1 7 f'` MC )14 Type of Ins tian: 4/1(1 re !� t} n I t�� //r�i(. 1 11 D ate Called S -t l Special Instructions. p L Date Wanted t ) 0 / ti i �' Requeste : ( w 1 • )4 . n"0-41, r ei 69 Phone`Nb: / 7.0LQ 0 V._- 7 1 01 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 t PER 20 ')431 -3670 IXIApproved per applicable codes. 0 Corrections required prior to approval. `` COMMENTS: �� Date: --, _1 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: InSpectory'.�, Y n 9 J. Date: P oject: �' -41 (1- 1 ___ l + " (V IL I )A4 Type of I�nsBection; - 1 1 I ti A d ess. • L / u � C Date Called: d. • 0 2.O Special Instructions: Date Wanted: a:m- Requester __.) c. c D i Phone No: 2-a u — L -) - 7r (9 r Approved per applicable codes. COMMENTS: INSPECTION RECORD Retain a copy with permit INSPECTI N NO. PERMIT N . CITY OF TUKWILA BUILDING DIVISION � `'� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. /c,„ " Date: /0--2 j-03 0 $47.00 REINSPECTIONf EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: [te: City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM I Project Name Perl ; 4 - / 0004 a Address hi L I c i )!''•/ i• LJ Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: FINALAPP.FRM , a f4 5 /I Authorized Signature Permit No. I) 0 3 - '1 Date T.F.D. Form F.P. 85 Suite # John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575•4404 • Fax (206) 575 CI DO3/44 Job Title i t 2 p klJ1 G A / A) A' Subject Checked By 577e Date S A 3 Job No. 03 0.3 FILE COPY.__,---- - S 7 E e L S 6L6 c T: J & Acre hi o 4 4 c ) e Sii t in A a /4044 c /J W c. a 1917 U /3 c CAMP :s` 22 jw. V// •k x Prt. Am ty.rl. 1,3 rod we- A Alf711ar : \ , I .r. (1.5 CAIA 44 g) . la 1 1..- A a ) Ca v O, 34 S er.: on ( �el,sie. 3 ('2 = 0. 3 ) /, fd40 S(LttiI" PA tor /l e 5 , P I-046. r N _ itbe ew4 ,( 12,E -ucs *Novo '4 T J,', 2' , ; V o, . 2 ,Ic MAY z � 0 + 1 1 - /3E4 / f s 0.200 k 3 r "T/700 0 : 3 + [ 'INN) 5/3 taNt 0 . dg,a c. t N, 37 s. 407 Dgrt q t ot4 _ I.o, tirA- g- Fr,t r s y op s 8-c.0 c- meow multi LCfrQJ 001 /S1 pp LL'W s (A) S &tiU- pA N,t.`T jcK3 : `f!X?d GJ35 /al /ft / pAlit c"F d(MtJ U £ tvt. */ Gam- Fet. J v a0 (b) (21$4 y Or° J/ i 14.s Iso Et t' LW' SO f skit t e fort S05 J lei G ?J 0 • 4-0 . ) Set cf1't / -i t r ,AciC■r : D.614 k �► ; 4-4.. I424 Sheet f of S CIS, °tTV� r , • r i ;, pER 1 - CE NTE n it- Ser1 28 .7.1 J6s , 4 = 4-x.72 CoArr/ rr3 t-tS YZ HS L T r 4 11 s t?.3I k/ tot. � Gt611 . a 2. 1n k 4 t4)c GQMp a 3.25 k toiv o f 1 ' T o e l4it-L. e7&&/ 11 r a P• 3 o 7 k e c/3 " vv. p, l a ic f 1 *'Z „d pe 4. '/z " ft 4 -7z hieriGr (3 " &s eel) pfit le 44 o. 7 S 4/a _ p, q k ptIL 1 it- 6 4-{v21 27 ; VA w I. thl 4 43 � q . k SPEC AS e ser . D,03 (#MY) Or h d 42,37$" Job Title By Z774 Date 5/03 03 Job No. D3D 31 Subject Checked Sheet .2 of k "t.0 fR4Cft Ilk • I I/ ,. 1V6A C- .CECT I'»1 Acs D.Z62 44 me,-) r (kL /r`) x 134.2' (krt.a ) ks,; ,a•o 5 , 7. e7 k ; ?dt, r At.) d' . 4-/z 2.7S'" 0k P 416 g ,44�- 1 Slk13 $ sots JmAk coo., P. a 3.25' 644 pL,4Qj 4 3 x 3 /0 GA • uSi.�G 4) Er' e, d,t s e' M.A 7' 3 .� 2 , l Z5 A . 3 7S tom . ).57 /ts, Pk 4 A - Gtoas .t .3.f ' 4 /3 1.00 k4: eAst !aihre- rK 0. Sly x (01s) . 0 ,44 eV.. l b 9 ©.7f 15r K 4/3 _ 36 ks: It m / 1 . 0 P .10 3 " ak G kcr om . /35 6 StAIS i. 1rx . ' : ;gat es: or J446 4.l4 = 72 x v. o 6 1/ P. 6 '74 " 1' 0. 576 = p (a) /2 is frko) /.5 ©ks, q G1. /v.5/4" So' 4ANa k ¢ (2,{ a. t C3 )(za f- to 4 2.17-Sgvi s a gil te Seth ftt 3 12.16 > > P.. Lb * /.6. Dia . ; peit. ;Ft xzzi. S.2- 1.4 = 2.0 f i t. .10 k /LELec.. y� = P,/1c$ x < 1.1x /z : 0.124,k /tot' , "` F A ,o8.5 (2 ) emfi! Afief 35/y r -c.( . I •09S 1�.s* At- 3.3 �� 1� 4 &Im' ( &_p..) 11 �' 2-1!/ of Sr 70 hi 640 '4 �t1�6N 0) l�C�3j�r I. J 4.. J 44# k $J% 4T-3,3154 -" 3. n 44•F' 3 fro 1.364o S !f /114 r G. a ( Tito cs ..-% Ss Nt = (2.1a /y)x 2 /2.‘o k" W f,l 6 A g C" o I /k.1 Ty" Fox. a/1,41)17y 14 tkl o /4 M 3.720- k M lu 10,7/ kc 16.c3 e 15 r .' 6 = "30 i'o: 'k < ,P, 3 ' Job Title Subject U 1100 at 413 a 14.47 LA) ) (rim) 513 + ( �� l��) 5 / 3 D. Po?, By B /Ac: Date .5 /a3 Job No. 0303/ Checked Sheet of 14s A4 4 ' Ca C t1M4Js Aiee 3p 1 WI 0.6 C- safirw 017-4 L/pJ . z A4 9 V51 Ma t. (e , 51 f # :t( ; 4 174 . CN g- P. (tZ? 411 & i t • 303 3 SCI a .107 •s,•.. . D010 a4.4 ue 2 Y,, /,175 Y ,1 • F 8? " Yo 2.3.. U0 M 5; 44 k' -4,, a 1 S. 92 o's '�i . �i 1t :6: : U) u_w ks� =1.7 l'. X3 I ��r . i• Z.G4 C�,�I%'IL�+S Y ;ref: J� 1" g Q , ..., 14 - is, ' v L ./ti L 56 ,,17 d . 1 4's = W �X k 7 0, 1` 4 ' 38.31' r v 34.2 Z kd,. ' list. a 1 •:D fr.* z F. I-0 D CI O co CIECt 4 Irk + iSicki . 0.34 + fl. S3 t D, 81 o k 4 /. 33 0 • - i w TR/! -xi sv big. : jt 4i2 yi Pc 3. ZS' i -rA. 1 7.11.f k J . Z LW &c c - 6 0. S6 Dte 4 1,33 • _ Z (c) We( vP s c.LJ /,J 6 z D. m1 ? Z. 3DO 0 p r z eta* 5 CIA Mw 41OS "" a#4E" SC� 2224.1.1 S €-►s M x 120$ � _�. G� oart►L,S Stu (I IS [ T V p Wt.) 2 2- 300 ) Jiffs c:9" , Pc; : 4 S c) L i 100, 04 7a? 0.i4 y VT s. 3h / 120" r t V = (7 ) c j f oC , 1— -WO ./9.." NxLT z ,4J; k ,e ( 2 li 9,5-.4460 figtt. /4,0re- pti.tre Tip * s8s 4-/3 % 110 ci, pen- t 11 ell., 44,21 tr)E,T14.1.10T cf6c Ta3pEc'r ?Pik 4 1.0 "Iv Vr V. 4k Job Title Subject pr COA//J & c ra, ,5 , L U � * L �T T 2041 — rip) c o 4.1/JccrO/.. PC 41 3 f, Y s 723 c ▪ 2 *df c. 7.1 rc.*'i 134k e0 UM A,y ; 0, .373 Ac r D,373 $1. ky4 • k( )( 7 Az (t)0,7Z C440 CoANkr. - fr /x 6z) I St- z.sy y /qr LA- • ..Txe r. P. z7' r+,. C r ,9, l 72 I 1- i- U ) • 2 ir ' 62 - 2 , SG /� • 19" C.v rt,if Q ite / /E k 7 /8 o. /aS w 1 .S2?) By p7/ Date Checked 4 /VA r .CAe. 0,6 4.s, JriJ A z i.: k Ge..07/1.0G S /114 t'G 0. M = 123 ror ok E ,44 � x c Z D . 243t) ;e = P.1197 4 4:- '- 44 /1f x b 1= i SS : (30 /i : O s. G /a 1 q4 ) 4 . I d r/ Ian' ;fzkld t L- 4 . NO A = 1368+ ,1S(Ss M ) 1638' '1 ok < 416 Q _ 0,2o" tots 4/ ^ r 53 e../›sen 704361 ? a . otip a . .a,., • /1 � 4- �. If 1 " , • .'' S I / 17. Job No. 030e Sheet 4 of k f, 34 44 tact z • Z a 6 -JJ U 0 co J i-- w 0 LQ = • a z � Z° LL! uj o • ( o � w w z • = o z Job Title BY 674 Date 510 7 Job No. 0 a as Subject _ 42 - 3.2„5/2. a 40,37,5" 0 , 37,5" = ' ( ) Z '11, 7,- re 9 7,4-7 lel.; er r . 3, G As; p= 0,3o -.c 7 (2,8c, k'i II 2 2 PI/ *11 Se" lc w 3.72 tc 76k t / j E !r'tii Checked 25. ks; n{x g D, kS 4 ,io Cm •= Q, FMS' Sheet .) of CkEc - / '` fi": = 0, zz. 4- 0.5 6. ce. 0,7Y i'4- € !. 35 rIZ4els) Z /71.. . 1 a' / a A g � ,At ' _ / 21 = L'.44 Alf 7 7 ' R� - I.:, 57 165 l ZS, 2- 4y SA fie/ • 3 ,1 4 k cvy • p . g o Crn, r 415 l / ` b - 91" , C 1.33 February 2, 2004 James H. Riddy 18249 Olympic Avenue South Tukwila, WA 98188 Dear Permit Holder: City of Tukwila Department of Community Development RE: Permit Application No. D03 -146 18249 Olympic Avenue South In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension ua to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to April 18, 2004, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 2su..Ld Stefanie Spencer Permit Technician Xc: Permit File No. 003 -146 Bob Benedicto, Building Official Steven M. Mullet, Mayor Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431.3670 • Fax: 206- 431 -3665 October 7, 2003 James H. Riddy 18249 Olympic Avenue South Tukwila, WA 98188 City of Tukwila RE: Permit Application No. D03 -146 18249 Olympic Avenue South Dear Permit Holder: Thank you for your cooperation in this matter. Sincerely, Stefania Spencer Permit Technician Xc: Permit File No. 003 -146 Bob Benedicto, Building Official Department of Community Development Steven M. Mullet, Mayor Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to November 18, 2003, your permit will become null and void and any further work on the project will require a new permit and associated fees. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206- 431 -3665 ACTIVITY NUMBER: D03 -146 DATE: 05 -14 -03 PROJECT NAME: PERFECT FIT -- MCDONALD INC SITE ADDRESS: 18249 OLYMPIC AV S X Original Plan Submittal DEPARTMENTS: d' Au) I Buil ing Division ( Public Works ❑ APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: Documents /routing slIp.doc 2-28-02 PERMIT COORD COP, PLAN REVIEW /ROUTING SLIP Response to Incomplete Letter # Response to Correction Letter # Revision # — After Permit Is Issued - 1l # WU 6-I4 Fire Prevention iz Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05 -15 -03 Complete [2" Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RO9TING: Please Route . f Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: FERMIT COORD COPY DUE DATE: 06 -12 -03 Approved ❑ Approved with Conditions E Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: STATE OF WASHINGTON COUNTY OF KING AFFCONT 1/13/00 CITY OF TL :WILA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION 1. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. , and will therefore not be performed by a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. _-- A. O ) ' 1 I P \SgION )- 1 +I "Go U NOTARY ', : 274 o day of May , 20 93 i / 1 PUBLIC .i I lie. _' cZ a. i(T �� Q'�'w � NOTARY PUBLIC in a n�� d"for the State of Washington, ss. , states as follows: APPLI Signed and sworn to before me this residing at k /h9 County. Name as commissioned: A/l ce A. Deacy My commission expires: 6 ~l6 0 H -4 .. u.- 1t.. .:•v �•�:•..�sr�4 ' aver; �.' �: wJy'_•"•::.' tv. 4�cYi.' wf. �ia� :i+.ti'�e- iUiY:r�4:�:f�Nin•1J .u:fi�t.41 «g lSiui'J;: 18.2.7.090 Exemptions. This chapter shall not apply to: 1. An authorized representative of the United States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of a structure; 6. Any construction, alteration, improvement, or repair of personal property, except this chapter shall apply to all mobile /manufactured housing. A mobile /manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 ROW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than $500, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division AFFCONT 1/13/00 of the operation is made into contracts of amounts less than $500 for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner who contracts for a project with a registered contractor; 12. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but this exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 13. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 14. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his license; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; 16. Contractors on highway projects who have been prequalified as required by chapter 13 of the Laws of 1961, RCW 47.28.070 with the department of transportation to perform highway construction, reconstruction, or maintenance work. • gr. cn� I u 0 A - j - t , o <(� �iM i szczt) 1 r cin . TAB 110 411 DRAWINGS PREPARED FOR Perfect Fit McDonald 18249 Olympic Ave South Tukwila, Wa 98188 50' -10" DATE APPROVED BY Coil Jeff (Mint -fl 8' —7" HeFEEEifiiiEFFEEEEil REiREFEEIEFEEI FEEEFEEEIBEE3E1 EFEWEEE±±7:12E:e 11111111111111111 IMO MIN MEI MINI 1•111111•111 IMMO HHH EMI 1111111i ----MN - MIN M1111111111a■■■■�1 =II MIMI iMI MEI - 1111111111 MI NS M - it ME [ill:: . J I '1 ENGINEERED PRODUCTS 18271 Andover Pork West Seattle, WA 98134 Phone: 206 - 394 -3312 Fox: 206 - 575 -6688 Cell#: 206 - 335 -7502 Storag and MaI•'II Hano'IIng Sp.cIaIIsts -CF 50 -2 THIS DRAM AND DESIGNS THEREON SHALL NOT BE OUPUCATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSES, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, %MOUT EXPRESS STEM CONSENT OF ENGINEERED PRODUCTS. ALL REPRODUCTIONS 94 L W8 TM NOTICE. 4' p A1 4 tOb C REVISION • • • ft 0 0o \I IIIIII■i , DRAWINGS PREPARED FOR Perfect Fit McDonald 18249 Olympic Ave South Tukwilo, Wo 98188 APPROVED DATE BY Calf Jaffe/ant ENGINEERED PRODUCTS 18271 Andover Park West Seattle, WA 98134 Phone: 206 - 394 -3312 Fax: 206 - 575 -6688 Cell /: 206 - 335 -7502 Storage and Material Handling Specialists N6 DRAM N DE'SICNNS 1N 1IEON SAL NOT OE OUPUGAJED. USED OR D1scios TO OMER y PURPOSES, D CEPT AS MERIN AUDI BY UMW, SMUT DIMS cONSDIT OF ENGINEERED PaooucrS. MIS NOTICE. 1 4 s ara REVISION ISSOUPTION • t 0 t N co 3 COMUMN ; L 3/4 "j 1 14 GA THK V SIDE PALLET RACK ELEVATIONS co 1 _ 8 ' -0 " FRONT SIDE 1 3/8" C\ - - .105" THK COMUMN co 1/8* V 3" j FOOT PLATE 1 /s• V 1 1/2" „ 14 GA THK COLUMN STRUT TYP 7/16" 0 (TYP) 4 '_ 0 " EASY -UP SHELVING ELEVATIONS 1/8" THK 2 i /a' FOOT PLATE 8' -0" BEAM (Ti'P) FRONT i LOAD BEAM • FLOOR ANCHOR DETAIL SEE NOTES FOR SPECS • 3/8' FLOOR ANCHOR DETAIL SEE NOTES FOR SPECS .09" THK s /a i /z it .oa' THK 1/21 I BEAM POST CONNECTOR fA STRUCTURAL NOTES - PALLET RACKS -„r ► . - •71 • p Y AN •N "T K II • . , CA 2. MINIMUM YIELD (Fy) AND ULTIMATE (Fu) STEEL STRENGHTS SHALL BE AS FOLLOWS: A BEAMS AND COLUMNS Fy = 50ksi Fu = 65ksi B BRACING STRUTS Fy = SOksi Fu = 65ksi C BASE PLATES Fy = 36ksi Fu • 58ksi 3. MAXIMUM RACK LOAD PER LEVEL PER PAIR OF BEAMS SHALL BE 2,000Ibs. 4. CONCRETE SLAB IS ASSUMED AS 6" THICK WITH fc' = 2,500psi 5. ALLOWABLE SOIL BEARING IS GIVEN AS 1,500 psf FOR GRAVITY LOADS. 6. TIE —DOWN ANCHORS SHALL BE HILTI KWIK BOLTS OR EQUIV USE: ONE (1) — 1/2"O X4 1/2 ANCHOR WITH 3" EMBEDMENT PER BASE PLATE. SPECIAL INSPECTION IS NOT REQUIRED 7. POST LOAD SIGNS NOT LESS THAN 50 SQUARE INCHES IN AREA DEPICTING THE DESIGN CAPACITY AT CONSPICUOUS LOCATIONS. 8. IF ANY DISCREPANCY OCCURS, CONTACT THE ENGINEER FOR CLARIFICATION. STRUCTURAL NOTES - EASY UP SHELVING 1. SHELVING IS MANUFACTURED BY EASY UP SHELVING AND SHALL BE EASY UP 7000 SERIES. 2. MINIMUM Y'ELD (Fy) AND ULTIMATE (Fu) STEEL STRENGHTS SHALL BE AS FOLLOWS: A) BEAMS AND COLUMNS AND POST CONNECTORS Fy = 42ksi Fu = 63ksi B) BASE PLATES Fy = 36ksi Fu = 58ksi 3. MAXIMUM SHELF SHALL BE 2501bs. 4. TIE —DOWN ANCHORS SHALL BE HILTI KWIK BOLTS OR EQUIV USE: ONE (1) — 3/8'0 X3 3/4' ANCHOR WITH 2 1/2' EMBEDMENT PER BASE PLATE. SPECIAL INSPECTION IS NOT REQUIRED 5. POST LOAD SIGNS NOT LESS THAN 50 SQUARE INCHES IN AREA DEPICTING THE DESIGN CAPACITY AT CONSPICUOUS LOCATIONS. 6. IF ANY DISCREPANCY OCCURS. CONTACT THE ENGINEER FOR CLARIFICATION. .103- itito • g r 0? 1 Cr v liZtolpsim*s Atily 1 � _ clu I04 of 2 0 2003 p V •