Loading...
HomeMy WebLinkAboutPermit D03-153 - SEARS - HOME IMPROVEMENTSEARS HOME IMPROVEMENT 3425 SOUTH 116T" ST EXPIRED 01-15-04 D03 -153 z a • Parcel No.: 1023049043 Permit Number: D03 -153 4T- Address: 3425 S 116 ST TUKW Issue Date: 07/07/2003 ce Suite No: Permit Expires On: 01/03/2004 t6 v co o Tenant: u.i H Name: SEARS HOME IMPROVEMENT Address: 3425 S 116 ST, TUKWILA WA w O Owner: g Name: AMB INSTITUTIONAL ALLIANCE Phone: Address: C/O MCELROY GEORGE & ASSOC, 3131 S VAUGHN WAY STE 301 1" a I- w Contact Person: z ~ Name: MIKE MCCLURE Phone: 206 - 226 -0556 Z O Address: 3425 S 116 ST, SUITE 109, TUKWILA WA al Do Contractor: 8 cn Name: SEARS HOME IMPROVEMENT PROD INC Phone: !7'- Address: 1024 FLORIDA CENTRAL PY, LONGWOOD FL = w Contractor License No: SEARSHI011LA Expiration Date: 11/26/2003 f- r- u O .. z w =_ O F— DESCRIPTION OF WORK: INSTALL 73 UPRIGHT PALLET RACKS WITH 290 CROSS BEAMS. Value of Construction: $ $0.00 Fees Collected: $280.46 Type of Fire Protection: Uniform Building Code Edition: 1997 Type of Construction: RACKS Occupancy per UBC: 0025 Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / ('206) 431 -3670 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N N N DEVELOPMENT PERMIT Number: 0 Size (Inches): 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Private: Profit: Private: D03 -153 Public: Non - Profit: Public: Printed: 07- 07.2003 z Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe• • rmance of work. I am authorized to sign and obtain this development permit. Signatur _ ,,��' Date: Print Name: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 "-�- Date: 7` 7-c73 le This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D03 -153 Printed: 07 -07 -2003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1023049043 Address: 3425 S 116 ST TUKW Suite No: Tenant: SEARS HOME IMPROVEMENT PERMIT CONDITIONS Permit Number: D03 -153 Status: ISSUED Applied Date: 05/20/2003 Issue Date: 07/07/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 4: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 r-- O Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). w ui 5: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be 0 N construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any p other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this w w code shall be valid. - v wI -O di 0 (1) HI- 0 6: ** *FIRE EXTINGUISHERS * ** - UFC Article 10 and NFPA 10. 7: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 8: ** *STORAGE PRACTICES * ** - UFC Article 81 @ 11 9: The critical storage height for high -piled combustible stock in closely packed piles is 12 feet. (UFC 9.110) Storage above 12 feet may necessitate increasing the sprinkler density to extra hazard and adding smoke removal capabilities. (UFC 8101) (NFPA 231) 10: To use any building or portion thereof exceeding 500 square feet for the storage of high -piled combustible stock. A floor plan showing the dimensions and location of the stockpiles and aisles shall be submitted with applications for such permits. (UFC 8101) 11: In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 13) 12: High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible materials on pallets or in racks more than 12 feet in height. For certain special- hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (UFC article 2, sec. 209 -H) 13: Maintain minimum 6" longitudinal flue space between back to back racks. (NFPA 13) 14: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinklers at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila doe: Conditions 003 -153 Printed: 07 -07 -2003 z Iz • w u� O 0 co n wz Mw w 0 g --JJ w ¢ z I z Sign. re: Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Fire Prevention Bureau. (NFPA 13) 15: Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row and multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted. (NFPA 231c 4 -3.1) 16: Aisles in sprinklered building shsall be 44 inches (1117.6 mm) or more in width. Aisles shall be 96 inches (2436.4 mm) or more in width in high -piled storage areas exceeding 2,500 square feet (232.26 m2) in area and designated to contain high- hazard commodities. Aisles shall be 96 inches (2438.4 mm) or more in width in public accessible areas where mechanical stocking methods are used. (U.F.C. 8102.10.2.2) 17: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 18: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the p, ormance of work. "rfor D03 -153 Date: 7 -7-c Printed: 07 -07 -2003 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA .98188 SITE LOCATION .; Tenant Name: S( Property Owners Name: / - rA , 1 Mailing Address: 3 S S /W 51- CONTACTPERSON Name: / e X Mailing Address: >ALM t" G(�fr� r•t. /. .' + Applications and plans must be complete in order to be accepted for plan Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: Site Address: 3 5 S, 116 5 Ste 109 Suite Number: /o 9 Floor: I S� New Tenant: .... Yes 0 ..No cC u ,e ate q � City State Zip E -Mail Address: Fax Number: Oeo . 4 8 (339 GENERAL CONTRACTOR INFORMATION. Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: Contractor Registration Number: 46 a I SEARS f 0 \applications\pamit application (3.2003) 3/2003 30 i�,I <� ro •'APIA ARCHITECT:OF.RECORD - All plans must be Wet stamped by Architect of Record • • ENGINEER: OF RECORD.- All plans must be wet stamped by Engineer of Record E -Mail Address: h . / / g Ii 4d1- , (OM �F e m 'ccraA± City Page 1 BUilding` No ' Mechanical PermitNo:'' Public Works Permit Na Project No :. ... . , . tmgx'c6'�'S review. Day Telephone: 06 - d $s , Company Name: �P00r5 h ?roe - . J n Mailing Address: /oil/ rh,r, t 4,,, Ce4"ro, ) k wy vn9,,Jo o L.- f - 3 7 750 City State Zip Contact Person: i ✓� E -Mail Address: State Zip /. 7 / /ro � State Zip t ae e Mr C dire Day Telephone: 206 Z76 D 5 Fax Number: 2- c2 S'c3 Expiration Date: /1 -.26- O 3 * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Company Name: Mailing Address: City Day Telephone: Fax Number: L i/ 0ar$" "c77 3 City State Zip Day Telephone:55 S 8Y, 7C Li Fax Number: 11 PERMIT IN 20 F ORMATION - 6 - 431 -3670 • Valuation of Ptojett (cotitiactor.'s bid price): $ Q ) 7 Scope of Work (please provide detailed information): 73 0 • Lt 'p` 'applicationatpermit application (3-2003) 3 /2003 Provide All Building Areas in Square Footage Below Page 2 Existing Building Valuation: $ 'v C re) P C Will there be new rack storage? V ..Yes 0.. No If "yes ", see Handout No. for requirements. PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over l8 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: "N Sprinklers A..Autontatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0..Yes 0..No /f "yes". attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. • Existing Interior Remodel Addition to Existing Structure New Type of Construction per UBC Type of Occupancy per UBC I Floor 2 Floor 3' Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck 11 PERMIT IN 20 F ORMATION - 6 - 431 -3670 • Valuation of Ptojett (cotitiactor.'s bid price): $ Q ) 7 Scope of Work (please provide detailed information): 73 0 • Lt 'p` 'applicationatpermit application (3-2003) 3 /2003 Provide All Building Areas in Square Footage Below Page 2 Existing Building Valuation: $ 'v C re) P C Will there be new rack storage? V ..Yes 0.. No If "yes ", see Handout No. for requirements. PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over l8 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: "N Sprinklers A..Autontatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0..Yes 0..No /f "yes". attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. • rrimes *pmc , PEIWIT INFORMATION ! '206 =433 -0179 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila 0 Water District #125 0 ... Water Availability Provided Sewer District ❑ ... Tukwila 0... ValVue ❑ .. Renton ❑ ...Seattle ❑ ...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size – 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance Cl ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitary Side Sewer ❑...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: \applications \permit application (3-2003) 3/2003 cubic yards cubic yards Please refer to Public Works Bulletin #1 for fees and estimate sheet. Call before you Dig: 1- 800 - 424 -5555 ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line I t „ „ ❑ ...Sewer ❑ ...Sewage Treatment ❑ .. Highline ❑ ...Renton ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ .. Maintenance Agreement(s) ❑...Hold.Harmless ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use – Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Permanent Water Meter Size... 77 WO# ❑...Temporary Water Meter Size.. 71 WO# ❑ ...Water Only Meter Size WO# ❑ ...Deduct Water Meter Size " ❑ ...Sewer Main Extension Public Private ❑ ...Water Main Extension Public — Private Page 3 City City ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding Day Telephone: State Zip State Zip Day Telephone: Unit Type: Qty : Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm/Ind MECHANICAL PERMIT INFORMATION MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: 206- 431 -3670 City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... ❑ Fuel Type: Electric ❑ Gas ....E] Other: Indicate type of mechanical work being installed and the quantity below: PERMIT-APPLICATION 'NOTES :Applicable ;to:all permits in this.application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF TH STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O R OR 8 AG S ignal re. Print Name: j4, ke "Ourc Mailing Address: 3 yp 5 5, 110 -4 � f STc /6'1 L j .. Date Application Accepted: 20 -v3 \applicalions\pcnnit application (3.2003) 3/2003 Date Application Expires: (-20 Page 4 Ray Telephone: 2e5(. ZZ. OS5 6'6 I L))9 UL Zip City State Date: Za ` 3 Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 1023049043 3425 S 116 ST TUKW SEARS HOME IMPROVEMENT R03 -00619 BLH ADMIN Payee: MIKE MCCLURE TRANSACTION LIST: Type Method Description Payment Check 5707 BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE RECEIPT Account Code 000/322.100 000/345.830 000/386.904 Permit Number: Status: Applied Date: Issue Date: Payment Amount: 280.46 Payment Date: 05/20/2003 01:28 PM Balance: $0.00 Amount 280.46 Current Pmts 167.25 108.71 4.50 Total: 280.46 D03 -153 PENDING 05/20/2003 0879 05/21 1716 TOTAL 280.46 Printed: 05 -20 -2003 BREAK ROOM R.R. CONFERENCE 32'X20' OFFICE ' a(+: pbYkLt: S. Rk. wew�.: riic :iit'J ": ✓:7 «�i'e�..�...a...,: K�.�,t(. OFFICE 14'X12' T OFFiCE • 14'X16' "V OFFICE • 14'X12' OFFICE ISMSEMEMMS A • a 0 73 � N �O avi CITY OF TW WIIA APPROVED MAY 73 Upr,i Gis MAY 3 0 2003 2 / a, Ire 5 S bFAN9S AS NU ; 1 E/ Fir.C;FrlED 1Ty ; IKW;; MAY 2 02003 If ammo 2 / M . N (lc Ok CA 1 AppRU V1P 33 3 "a3 n Pallet Racks Sears Home Pro Tukwila, WA for Sears Home Pro Seattle, WA FILE COPY 1997 Uniform Building Code RECEIVED CITY OF TUKWILA MAY 2 0 2003 PERMIT CENTEI: by William T. Guiher, P.E. 654 Springs Lane Cincinnati, OH 45255 -5015 5 13/947 -1145 EXPIRES tf9 MAR 2004 17 MAY 2003 Do- i53 WILLIAM T. GUIHER, P. Tabl e of Contents J Introduction 1 Design Parameters 1 Loads 1 50 ", 92 ", & 94" Beams 1 3 x 1 Posts 2 3x3 Posts 4 3 x 1% Seismic Analysis 5 Lateral Load - Transverse 5 Lateral Load - Longitudinal 6 3 x 3 Seismic Analysis 7 Lateral Load - Transverse 7 Lateral Load - Longitudinal 8 Bracing 8 Horizontal 9 Diagonal 9 3 x 1% Base Plate Design 10 3 x 1 Bolt Size 10 3 x 3 Base Plate Design 10 3 x 3 Bolt Size 12 Beam Connectors 12 Beam Weld 13 May 15, 2003 Sears Home Pro, Tukwila, WA WILLIAM T. GUIHER, P.E. Introduction This system is shown in plan view on drawing Sheet 1 with elevations and loadings on Sheet 2 and rack details on Sheet 3. These racks store residential siding products. See plans for product and weight identification. Design Parameters Loads May 15, 2003 Code = 1997 UBC, Division X Zone(Figure 16 -2) = 3 Z (Table 16 -I) = 0.30 Soil Type (Table 16 -J) = D (default) Occupancy Factor (Table 16 -K) = 1.0 R (Section 2228.5.2) = 4.4 & 5.6 (transverse & longitudinal) Na (Table 16 -S) = 1.0 (> 10 miles from fault) Nv (Table 16 -T) = 1.0 (> 10 miles from fault) Ca (Table 16 -Q) = 0.36 Cv (Table 16 -R) = 0.54 The shelves are all hand stacked. Refer to plans for loads in each rack type. 50 ", 92 ", & 94" Beams A 94" Type 2 Front Eieyation Sears Home Pro, Tukwila, WA k Page 1of13 WILLIAM T. GUIHER, P.E. All configurations utilize beams with the same cross section. The first occurrence of long beams is in the Type 2 configuration. The heaviest loading for this beam is in the Type 3 configuration at 1890 lbs. per shelf. Please note that Types 2 & 3 actually store loads that span from the back rack row to the front. This beam is designated "IBX40096" by the manufacturer. The beams are a 4" high by 2 wide tubular step beam of 16 gage (0.060) material. The manufacturer has also supplied the following properties for this beam: May 1S, 2003 F = 50 ksi F = 55 ksi I = 1.526 in' S. = 0.729 in W = 1890 / 2 * 2 to account for the load in the wide flue space = 1890 lbs / beam M. = WQ / 8 = 1.89 * 94 / 8 = 22.21 in -k f = M / S = 22.21 / 0.729 = 30.49 ksi Fb = 0.60 F = 33 ksi > 30.49 ksi = 5 W 2 _ 5 * 1.890 * 94 - 0.454 in. Simple beam deflection. 384 E I 384 * 29500 * 1.526 Aallowable = Q / 180 = 94 / 180 = 0.522 in. > 0.454 in. Frame Depth = 48 in. First Horizontal = 8 in. Sears Home Pro, Tukwila, WA OK OK 3 x 1% Posts The post is a 3 x 1% x 14 ga. section with a pinned base for configurations 5 through 11. All other configurations use a 3 x 3 x 14 ga. post with a fixed base. The configurations 10 & 11 have the highest design ratio for dead load + live load. P= 350LL+ 150DL =0.50k Page 2 of 13 WILLIAM T. GUIHER, P.E. Second Diagonal = 48 in. Dead Load, Live Load P =0.5 kips M = 0 in -k M = 0 in -k Q. = 96 in. Q = 38 in. Q = 38 in. Post =3x1% Net Area = 0.450 in I = 0.783 in S. = 0.522 in r = 1.177 in. r = 1.99 in. J = 0.001175 in C =0.62 kQ / r = 138.67 kQ / r = 58.02 k = 30.40 f = 1.11 ksi fb. = 0.00 ksi f = 0.00 ksi F'e. = 15.14 ksi Fe = 86.50 ksi at = 93.23 ksi F'e = 13.84 ksi F = 7.04 kips May 15, 2003 E = 29,500 ksi G = 11,300 ksi k = 1.7 k = 1 k = 0.80 t = 0.072 in. Gross Area = 0.565 in I = 0.242 in S = 0.239 in r = 0.655 in. X = -1.464 in. F = 50 ksi Beta = 0.459 ASD S2 c =1.8 Fb = 30 ksi C. = 0.85 C = 1 Eq. C4.1 -1 of +F'ex = 108.38 ksi Min Fe = 13.84 ksi = 1.90080 Ae = RMI- Ae = [1 - (1 -Q) * (Fn/F'y)Q] * Anet mitt Fn = 12.14 ksi Ae = 0.431 in Paiiow = 3.17 kips > 0.50 k Sears Home Pro, Tukwila, WA Q = 0.856 OK Page 3 of 13 WILLIAM T. GUIHER, P. 3 x 3 Posts The post is a 3 x 3 x 14 ga. section with a fixed base. The configuration 3 has the highest design ratio for dead load + live load. P = (1.89 / 2 + 0.05) * 5 = 4.975 k Frame Depth = First Horizontal = Second Diagonal = Dead Load, Live Load P = 4.975 kips M = 0 in -k M = 0 in -k V. = 28 in. Qy = 38 in. Q = 38 in. Post = 3 x 3 Net Area = 0.610 in I = 1.145 in S = 0.763 in r = 1.265 in. r = 3.283 in. J = 0.001236 in C = 2.365 kQ /r =37.63 kQ /r =32.79 k = 30.40 f =8.16 ksi fbx = 0.00 ksi f = 0.00 ksi F'e = 205.63 ksi Fe = 270.85 ksi at = 98.50 ksi May 15, 2003 48 in. 8 in. 48 in. E = 29,500 ksi G = 11,300 ksi k = 1.7 k = 1 k = 0.80 t = 0.072 in. Gross Area = 0.715 in l = 0.961 in S = 0.542 in r = 1.159 in. X. = -2.799 in. F = 50 ksi Beta = 0.273 ASD Si =1.8 Fb = 30 ksi Cmx = 0.85 C = 1 Eq. C4.1 -1 at +F'ex = 304.13 ksi Sears Horne Pro, Tukwila, WA Q = 0.787 Page 4 of 13 WILLIAM T. GUIHER, P.E. Fie = 71.14 ksi Min Fe = 71.14 ksi = 0.83836 Ae = RMI- Ae = [1 - (1 -Q) * (Fn/Fy)Q] * Anet min. Fn = 37.26 ksi Ae = 0.507 in' Pallow = 11.45 kips > 4.975 k F = 18.77 kips 3 x 1% Seismic Analysis All conditions were checked. The critical condition is shown here. It continues to be 10 & 11 Fundamental Period of Vibration. Conservatively assume the period is < 0.5 seconds and the default values apply. T = 0.50 seconds Maximum of (V V s V s V3 V =0.11 C = 0.11 * 0.36 * 1.0 W = 0.0396 W V2 ( Not applicable to zone 3) V3 = 2.5Ca I *W - 2.5 * 0.36 * 1.0 = 0.1607W R 5.6 V - C„I = 0.54 * 1.OW = 0.1929 W > 0.1607 W R T 5.6 * 0.50 W = 100% * 0.500 = 0.50 k per post Viongitudinal = 0.1607 * 0.5 = 0.080 kips per post Vtransverso = 2.5 * 0.36 * 1.0 / 4.4 W = 0.2045 W = 0.205 kips / frame Lateral Load - Transverse May 15, 2003 Sears Home Pro, Tukwila, WA OK The critical direction when considering anchorage is perpendicular to the 48 in. Page 5 of 13 WILLIAM T. GUIHER, P.E. base dimension. The base shear on each post will be half the total force, or 0.102 kips. The overturning moment is achieved by applying the lateral load in an inverted triangular fashion except in this case, since there is only one load level, the lateral load shall be applied at the storage level. Thus, the unit overturning moment is: M = V *E (H * h ) = 0.205 * 96 = 19.68 in -k The resulting post loads (overturning uplift) = M / d = 0.41 kips. The net uplifting reaction = 0.41 - 0.50 * 0.9 = 0 kips. Assume concrete f'c = 3000 psi U? (L, w 4 a -J LL Q ci) = � z � All posts are to receive (1) 1 /2" 4) expansion anchor with embedment without w o uj U � U OK oF= w W Allowable shear = 1.74 k > 0.102 k required OK o wz 0 z special inspection - Hilti Kwik Bolt II, ICBO #4627. Pallowable = 0.50 k > 0.41 > 0 k Post Check. To calculate ?total add the E load to DL +LL. P = 0.50 + 0.41 = 0.91 kips < 3.17 * 1.33 k from above. OK Lateral Load - Longitudinal M = 0.080 * 96 = 7.68 in -k f M/S= 7.6810.522= 14.71 ksi f = 1.11 ksi F = 7.04 * 1.33 = 9.36 ksi f /F 1.11 /9.36 = 0.119 <0.15 Fb = 30 * 1.33 = 40 ksi f /F 14.71 /40 =0.368 E= 0.119 +0.368 = 0.487 <1.00 May 15, 2003 Sears Home Pro, Tukwila, WA 3) `. OK Page 6 of 13 .....u y. ' .. ..� 4 WILLIAM T. GUIHER, P.E. 3 x 3 Seismic Analysis All conditions were checked. The critical condition, is shown here. It continues to be 3 for this size post - z ce Fundamental Period of Vibration. -1 o co 0 Conservatively assume the period is < 0.5 seconds and the default values apply. w T = 0.50 seconds cn u . w o Maximum of (V V s V s V3 g u a V =0.11 C = d = 0.11 * 0.36 * 1.0 W = 0.0396 W z � V2 ( Not applicable to zone 3) z o 2.5C I 2.5 *0.36 *1 w v _ 3 R a * 5.6 W = 0.1607W j o U ON a4- V- IW - 5.6 * 1.0 = 0.1929 W > 0.1607 W w RT 5.6 *0.50 U W = 100% * 4.98 = 4.98 k per post Vlongitudinal = 0.1607 * 4.98 = 0.800 kips per post V transverse = 2 . 5 * 0.36 * 1.0 / 4.4 W = 0.2045 W = 2.037 kips / frame Lateral Load - Transverse The critical direction when considering anchorage is perpendicular to the 42 in. base dimension. The base shear on each post will be half the total force, or 1.019 kips. The overturning moment is achieved by applying the lateral load in an inverted triangular fashion using 2/3 of the height. Thus, the unit overturning moment is: M = V * E (H * h ) = 2.037 * 2/3 * 138 = 187.404 in -k The resulting post loads (overturning uplift) = M / d = 4.462 kips. The net uplifting reaction = 4.462 - 4.98 * 0.9 -0.02 = 0 kips. May 15, 2003 Sears Home Pro, Tukwila, WA Page 7 of 13 z Assume concrete f'c = 3000 psi All posts are to receive (1) 1 /2" 4) expansion anchor with -ate embedment without special inspection - Hilti Kwik Bolt II, ICBO #4627. Pallowable = 0.50 k > O k Allowable shear = 1.74 k > 1.019 k required � LL in u_¢ • d P = 4.98 + 4.462 = 9.442 kips < 11.45 * 1.33 k from above. OK i z � � z �- w • w U � O — O H w w I- LI. U= o � z Post Check. To calculate ?total add the E load to DL +LL. Lateral Load - Longitudinal M (fixed base) = 0.625 * 28 * 0.800 = 14.00 in -k f =M /S= 14.00 / 0.763 = 18.35 ksi f = 8.16 ksi F = 18.77 * 1.33 = 24.96 ksi fa / F = 8.16 / 24.96 = 0.327 > 0.15 Fb = 30 * 1.33 = 40 ksi C = 0.85 F' = 1.33 * 71.14 = 94.62 ksi C — 0.85 *18.35 _ 0.427 rl 1 8.16 40 F 94.62 E = 0.327 + 0.427 = 0.754 < 1.00 Bracing 16 ga. F = 50 ksi May 15, 2003 t = 0.060 Sears Home Pro, Tukwila, WA OK OK OK Page 8 of 13 Z JU O 0 W = J Q = 36 in. Q = 36 in. kQ / r = 83 May 15, 2003 0.25 k = 0.8 k = 0.8 Area = 0.233 in r = 0.347 in Horizontal Length of bottom horizontal = 42 - 2 * 3 = 36 P = 2.037 kips f = 2.037 / 0.233 = 8.74 ksi F = 15.02 * 1.33 > 8.74 kips OK Diagonal Length of diagonal = J38 + 36 = 52.35 in. Maximum compression is 2.037 * 52.35 / 36 = 2.962 k kQ / r = 0.8 * 52.35 / 0.347 = 120.7 f = P / A = 2.962 / 0.233 = 12.71 ksi F = 10.17 * 1.33 ksi = 13.53 > 12.71 ksi Sears Home Pro, Tukwila, WA OK Page 9 of 13 WILLIAM T. GUIHER, P. 3 x 1% Base Plate Design Maximum P = 0.50 k Area inside column = 0.95 b * 0.95 d b = 1.625 d = 3.0 A = 0.95 * 1.625 * 0.95 * 3.0 = 4.4 in f =P /A= 0.50/4.4= 114 psi For columns on slabs, F = 0.7 f'c f'cminimum = 3,000 psi concrete F = 0.7 * 3000 = 2100 psi > 114 within column Plate thickness is absolute minimum. No bending in plate. 3 x 1 Bolt Size Since no base fixity is required, see earlier design checks ( /2" Hilti ICBO # 4627 w/ £-'c" minimum embedment without special inspection). OK 3 x 3 Base Plate Design Maximum P = 4.98 k Area inside column = 0.95 b * 0.95 d b = 3.0 d = 3.0 A = 0.95 * 3.0 * 0.95 * 3.0 = 8.12 in f = P / A = 4.98 / 8.12 = 613 psi For columns on slabs, F = 0.7 f'c f'c minimum = 3,000 psi concrete May 15, 2003 Sears Home Pro, Tukwila, WA OK Page 10 of 13 F = 0.7 * 3000 = 2100 psi > 613 within column Plate thickness is absolute minimum. No bending in plate. Check Bending Moment M = 14.0 in -k Distance between the holes is 5" while the overall plate length is 7 d = 5 / 2 + 2/3 * 7 / 2 = 2.5 + 2.33 = 4.83 " P =M /d= 14/4.83 =2.90 The pressure from the uniform load is added to this pressure to generate the edge pressure. Combine pressures to calculate base plate thickness, t. n = (7 - 0.95 * 3) / 2 = 2.075 " f = 0.331 + 0.142 = 0.473 ksi maximum pressure f = 0.473 - (0.331 / 3.5) * 2.075 = 0.277 ksi minimum pressure on design. area Theoretical moment = f n / 2 Actual moment = f n / 2 + (f - f n / 3 Equate these and solve for f: f = (2 f + f / 3 = (2 * 0.277 + 0.473) / 3 = 0.342 ksi t = 2 n j f/F y = 2 * 2.075 V0.342 / 36 = 0.404 " use 3 /8" May 15, 2003 C=P= '/2(7/2) *f *5 f = 4 * 2.9 / (5 * 7) = 0.331 ksi f„ =P /A=4.98/35=0.142ksi E Moments about C =M -P *2.33 -Td =0 T = (14 - 4.98 * 2.33) / 4.83 = 0.496 kips Sears Home Pro, Tukwila, WA OK OK Page 11 of 13 WILLIAM T. GUIHER, P.E. 3 x 3 Bolt Size 1/2" 4) Hilti ICBO # 4627 w /•2-V'' minimum embedment without special inspection capacity in tension = 0.500 > 0.496 k required OK Allowable shear = 1.74 k > 1.019 / 2 k required (also see above.) OK Beam Connectors May 15, 2003 0,800 2M = 0.800 * 10.5 + 0.785 * 14 = 19.39 in -k M / connector = 19.39 / 2 = 9.695 in -k The connectors are 10 ga. angles. -> T 2 2 T Seismic overturning moment is resisted by connector angles on each end of the beam. 0.800 - 0.015 = 0.785 M 28/2 =14" 0.080* 0.182 = 0.015 0.375 * 28 = 10.5" Sears Home Pro, Tukwila, WA Page 12 of 13 WILLIAM T. GUIHER, P. The vertical distance between pins is 4 ". T = M / 4 = 2.424 kips V = 1.89 / 4 / 2 = 0.236 kips R = , IT2 + V = 2.435 kips Each pin is 0.375" 4). Area = 0.1105 in f„= T /A =2. 435/0.1105= 22.04 ksi <1.33 *0.4Fy= 1.33 * 0.4 * 50 = 26.6 .ksi OK Beam Weld The beam is welded to the connector angle with a 1/8" fillet weld in front and behind the beam along the full height. (Series E70 electrodes) Q = 2 *(4 +2.5) =13.O in. F„ allowable = 0.30 * 70 * 0.707 = 21.3 ksi M = 9.696 in -k P= 1.89/4= 0.088k S = 0.125 (4) / 6 + 0.125 * 2.5 / 6 = 0.464 in = M / S = 9.696 / 0.464 = 20.90 ksi =P /A= 1.89/ 13= 0.15ksi f„ resultant = l i f b2 + L2 20.91 ksi < 21.3 ksi May 15, 2003 Sears Home Pro, Tukwila, WA OK Page 13 of 13 December 8, 2003 Mike McClure 3425 South 116th St, Ste 109 Tukwila, WA 98168 City of Tukwila Department of Community Development RE: Permit Application No. D03 -153 3425 South 116th St Dear Permit Holder: Steven M. Mullet, Mayor Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and/or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to January 3, 2004, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer Permit Technician Xc: Permit File No. D03 -153 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: D03 -153 DATE: 5 -20 -03 PROJECT NAME: SEARS HOME IMPROVEMENT SITE ADDRESS: 3425 S 116 ST, SUITE 109 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Buildin g ivision Public Works PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP b iz -0 n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUES /THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documenlshouting stip.doc 2-28.02 Fire Prevention Structural ❑ u Planning Division Permit Coordinator DUE DATE: 5-22-03 No further Review Required DATE: DUE DATE: 6-19-03 ❑ Incomplete n Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: U Approved n Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: May 20 13 01:48p SF'J.•2 PERMITS #LICENSING 4077P ?853G F62: 352 -000 (8/97) Detach And Display Certificate REGISTERED AS PROVIDED BY LAW ASj CONST CONT.' •. GENERAL' c ..0..1 ' 1° ''SEARSHI O11L T 1/26/20.3 • ' EFFECTIVE,a'DATE�: :i /0.1./`29'9 - SEARS. •i INC 1024 FLORIDA•`CENTRAI;'PI WY'•,'. :'• LONGWOOD: ' • "' ' .. Signature • • • • • _ . ... • • Issued by DEPARi"iMENT.OF LABOR AND J p.1 Please Remove And Sign Identification Card Before Placing In Billfold V TITLE PLAN VIEW 73'- 3" 1'- 3 3 •■••••/..01 14'-4' V 15'-2 3 3 4 , e• 411.1AP.,100111111mINIMparam•MINIIIIM 8'-2 791_2w 1 0 57 • 10 11 11 35 1_ 7 . 11 r 9 7'-6' 9 8 26 9' 8 8 6 24'-6' 8'-8' 7 6 12 13 14 5 5 5 5 5 5 5 5 5 5 5 5 5 4 4 4 4 4 4 4 4 4 4 4 56'-6" 4 4 4 0 11 1 3'-6' 11 9 1 1'-8' 15'-5' 7'-2' 11 8'8' 7 1_ 4 8 -0' \1/40 1' 6' kit' Yi 7'-6' BREAK ROOM OFFICE 12' X 12' OFFICE 14' X 12' OFFICE - 14' X 12' FFICE 13' X 12' R.R. R.R. ••••••••••••• ....•••••••■•••••••••••■• OFFICE EXPIRE 41441 OFFICE 14' X 16' Clif Of TtiVilla APPROVO MAY 30 2003 04z) thik.3 Ell CING ftSiCiN RECEIVE CITY °F -rt3"4" WO ° ZW3 pERtio ‘" SHALL 77 WORK WITHOUTBE MADE TO 4 I SML OF TUKWILA BUILDING DIVISION. Lift IINIMIIONS MILL IMRE A MEW PIM OLIMBITAL Alsa MAY SCAM ACOMONAL IRAN 110111M/ CONFERENCE 32' X 20' FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authOze the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. D05-155 S I • ••• . X C 0 0 C 1 • •womo C.5 PROJECT SEATTLE, WA 73 SEARS HOME PRO TUKWILA, WA for SEARS HOME PRO SHEET NO. 4 DI_ 2EEL 17 MAY 2003 REVISIONS DATE: 5/9/2003 JOB # 2462 SCALE: , 3/16" = 1"-0" DRAWN BY: MAH 0 5 kid tferotn. MU drawing and tnJbrnatton r .tibia to Minn on demand. V TITLE PLAN VIEW 73'- 3" 1'- 3 3 •■••••/..01 14'-4' V 15'-2 3 3 4 , e• 411.1AP.,100111111mINIMparam•MINIIIIM 8'-2 791_2w 1 0 57 • 10 11 11 35 1_ 7 . 11 r 9 7'-6' 9 8 26 9' 8 8 6 24'-6' 8'-8' 7 6 12 13 14 5 5 5 5 5 5 5 5 5 5 5 5 5 4 4 4 4 4 4 4 4 4 4 4 56'-6" 4 4 4 0 11 1 3'-6' 11 9 1 1'-8' 15'-5' 7'-2' 11 8'8' 7 1_ 4 8 -0' \1/40 1' 6' kit' Yi 7'-6' BREAK ROOM OFFICE 12' X 12' OFFICE 14' X 12' OFFICE - 14' X 12' FFICE 13' X 12' R.R. R.R. ••••••••••••• ....•••••••■•••••••••••■• OFFICE EXPIRE 41441 OFFICE 14' X 16' Clif Of TtiVilla APPROVO MAY 30 2003 04z) thik.3 Ell CING ftSiCiN RECEIVE CITY °F -rt3"4" WO ° ZW3 pERtio ‘" SHALL 77 WORK WITHOUTBE MADE TO 4 I SML OF TUKWILA BUILDING DIVISION. Lift IINIMIIONS MILL IMRE A MEW PIM OLIMBITAL Alsa MAY SCAM ACOMONAL IRAN 110111M/ CONFERENCE 32' X 20' FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authOze the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. D05-155 S I • ••• . X C 0 0 C 1 • •womo C.5 PROJECT SEATTLE, WA 73 SEARS HOME PRO TUKWILA, WA for SEARS HOME PRO SHEET NO. 4 ■ ■ S C cl RAYPm/ OF WASt "Y,� 4P �t ^ , 4 904 <r k?,S/ osLIt 411 4 NA TI L I EXPIRES 0 3 MAR 17 MAY 2003 REVISIONS DATE 5/9/2003 JOB # 2462 SCALE: 8 „ _ „ 0 „ DRAWN BY: MAH C o 1 C. 5 . rd Shemin. This drawing and irthrenation subject to Muni on doinand. A • 1 a • • CROSS JAR CROSS BAR NOTE: THE ANCHORS SHALL NOT BE LOCATED WITHIN 3F A SLAB JOINT. A pK USE 1 /2" RND HILTI OWIK BOLT II. EMBED 31 MIN ICBO #4627 SIDE ELEVATION USE 1/2" RND HILTI OWIK BOLT II. EMBED 3y MIN ICAO #4627 �. SIDE ELEVATION CROSS BAR P24 NOTE: THE ANCHORS SHALL NOT BE LOCATED WITHIN 3" OF A SLAB JOINT. n42 S6' 500 us f 1 r CROSS BAR .44 USE 1 /2" RNO HILTI OWIK BOLT 11. EMBED 3� MIN IC•O *4627 ' CROSS BAR __ v SQ0 LOS 92' r - 48 . - 1 USE 1 /2" RND HILTI OWIK ICB II. EMBED 3)+Z IN SIDE ELEVATION NOTE: THE ANCHORS SHALL NOT BE LOCATED WITHIN 3" OF A SLAB JOINT. 8 LBS FRONT ELEVATION NOTE: '4° T & Special Inspection of the anchors IS required. CROSS BAR P18 44 USE 1/2" RNO HILTI OWIK BOLT R. EMBED 3 MIN ICBO #4627 SIDE ELEVATION 81' RACK 1 94' U.N.O. NOTE: THE ANCHORS SMALL NOT BE LOCATED WITHIN 3" OF A SLAB JOINT. 131' 9 138' 94' TYP USE 1/2" RNO H TI OWIK BOLT 11, EMBED 3 MIN ICBO #4627 s. - 24 ' - CROSS P18 7 500 LOS 91' TYPJ 6' -6 FRONT ELEVATION FRONT ELEVATION SIDE ELEVATION NOTE: $Ol Special Inspection of the anchors IS required. 300 LBS 300 LBS RACK 6 NOTE: HST ti Special Inspection of the anchors IS 500 LBS 500 LBS USE 1/2" RND HILTI OWIK BOLT II. EMBED 3! MIN ICBO #4627 1 THE ANCHORS SHALL NOT BE LOCATED WITHIN r OF A SLAB JOINT. 300 LBS 8 8 8 9 9 NO LOAD , 500 LBS 500 LOS 26' -9' 9 500 LBS CROSS BAR FRONT ELEVATION RACK 4 NOTE: MOT Special Inspection of the anchors IS required. A A 2" TY 500 LBS 500 LBS RACK 7, 8 & 9 8 J 11 V 1 LBS 1.050 LBS T 121' 87' 54' 13' -0' 47' -9' FRONT ELEVATION NOTE: NAT NOTE. Special insimction of the anchors IS equired. CROSS BAR 8' _tr USE 1/2" RND HILTI OWIK BOLT II. EMBED 3 14IN IC80 #4627 SIDE ELEVATION NOTE: THE ANCHORS SHALL NOT BE LOCATED WITHIN 3" OF A SLAB JOINT. USE 1/2" RND HILTI OWIK SOLT �4ezi�o 3y MIN OM - •- 4$' --'- 1 0 RACK 2 CROSS BAR P18 USE 1/2" RHO HILTI OWIK BOLT II, EMBED 3t, MIN ICBO #4627 Z 400 LBS 7 SIDE ELEVATION NOTE: THE ANCHORS SHALL NOT BE LOCATED WITHIN 3" OF A SLAB JOINT. 42 , 13 I 1,050 LOS 1.050 Lill 1,050 LBS 4 ,S USE 1/2" RNO T1 OWIK BOLT N. EMBED 3 r WIN ICBO #4027 Z, SIDE ELEVATION L -50' TYP-J NOTE: THE ANCHORS SHALL NOT K LOCATED WITHIN 3 OP A SLAB JOINT. 1 8 r 138' LOAD OVER 2 BEAMS TNRU- LOADING P18 USE 1/2" RND HILTI OWIK BOLT II, EMBED 3S MIN ICBO #4627 " Z. USE 1/2" RND 1411.T1 OWIK BOLT 11. EMBED 3S MIN COO #4627 '2. 10 . uS 100' L 50' T YPI P24 CROSS BAR SIDE ELEVATION NOTE: THE ANCHORS SHALL NOT BE LOCATED WITHIN r OF A SLAB JOINT. 10 11 350 LBS 96' 500 LBS 500 LBS 500 LBS 1 IWO S 12 r -42 " -- t 4 __.._.....+ USE 1/2 RNO TI OWIK BOLT II. EMBED 3 MIN ICSO #4027 FRONT ELEVATION NOTE: NOT . 1 ,, Special Inspection of the anchors IS required. 350 L@s 103' 4 TYP—+ 11 350 LBS FRONT ELEVATION NOTE: ri ® Special Inspection of the anchors IS required. 500 LBS 24' -6' CROSS BAR 57' -8' 35'- 7' 11 13 500 LOS 7 350 LBS FRONT ELEVATION 11 39Q LBS RACK 10 & 11 500 LBS S00 LBS 94• FRONT ELEVATION 14 127' 11 NOTE: NOT at Special InspeetIon of the onshore IS required. 350 LBS 16'-3' >'l 11 NO L 350 LBS 144' RACK 12, 13 & 14 1,$90 LBS 1,850 LOS 1.890 LOS 1.190 LOS RACK 3 RACK 5 138' NOTE: 19 r tt Special Inspection of the anchors IS required. NO LOAD .4# o v y 2 13 2003 1 60 CITY Of T ' MAY 3 0 200 Is with '4= PROJECT SEARS HOME PRO TUKWILA, WA for SEARS HOME PRO SEATTLE, WA TITLE ELEVATIONS SHEET N0. 2 i • +-' X 0 C L� C U C U o ai si fel 4) • a TOP Of THE LOAD iANY P6 141, Cr l' °* WAS1141f 4 0 $"' . /I 4 ' V 40 1 c°6 7 A9 - t , t , s/kGismfo l F 6 '401y A 1. Wows 0 3 MAR 17 MAY 200 REVISIONS DATE: 5/9/2003 J o: # 2462 SCALE: N.T.S. DRAWN BY: MAH P 015 33 ita(nod thar,4n. Thus drawing and injbmatton d 4s avbfact to ratan on demand. , • 3' 6" 3/2 4/- 3 /_ 4 // 3 // IU184P0144 42 x 144 raPP. 4 1/2" 1/8 1/2 1/8" 0.3270- BRACING CHANNEL E LII 1/4' R5/64" - [ 0.6600 1 1/2" 0.5337 2.000 3.00 0.8375 0.8282 0.7113 ,/////,/,//,/, 1■1111111 0.5313 R0.08 (2) plcs 0.540 R1/8 (2) plcs 0.73 3.00 2.0625 POST SECTION 3 X 1 5/8 (P18) f -0.7 ' 13 R0.08 (2) plcs I- R1/8 (2) ptcs 0.4688 POST SECTION 3 X 3 (P24) • ■ 4, • 11 0.6600 I 0.5275 1.0919 0.0270 -4 R0359 1 R0.2050 0.7500 • 1 Front View 2.00 f Back View F -- L . 1.45-1.55 4.00 Tube Profile R1/4" (4) plcs 0.2050-0+,0 0 (2) plcs 3 1/4" - 1 5/8" ref Weld Pattern FOOTPLATE FOR P18 FOOTPLATE FOR P24 3/16 dia 0 0 - 3 3/4' 4 1/4" 0 4" BEAM 1 5/32' lcs 1 5/32" 1/2' 00 2.00 4.00 Beam Length most be square to 1/32" Connectors must be parallel to the face of the .0.111111.0111•001•11■•■ 9/16" dia thru 2 holes The top of the tube i =must be flush with the top of connector REQUIRES (1) 1/2"0 HILTI ANCHORS #4627 OR EQUIVALENT PER POST PROVIDE 4-1-7 MIN. EMBED. 31 /1 " PL - 3/8X5X0-7 REQUIRES (2) 1/2'0 HILTI ANCHORS #4627 PER POST . PROVIDE Q----17‘4" MIN. EMBED. ‘3 4_ ALNI Top View 4 114 4te #1\ Material 1. CONNECTOR: 9 gauge (.141-.148) 2. TUBE: 16 gauge (.058-.065) - Non Heights (3.5, 4.0, 4.5, 5.0) or TUBE: 14 gauge (.065-.075) - Non Heights (5.5, 6.0) ASTM A570/607 GR55 3. HIGH QUALITY QRETHANE PAINT 4, RMI97 COMPLIANT RACK SYSTEMS tube 1 14 * **5) VlO ak liPw \ • CO Of MOO ORONO 4t 30 2.001 ls i.0 Et) 1 GE \j 1 WS 2 c t \ p" 1 s3 V 0 TITLE 3 • - X 0 0 CLL. C U C C PROJECT DETAILS • • CNI 0) SEARS HOME PRO TUKWILA, WA for SEARS HOME PRO SEATTLE, WA SHEET NO. • •