HomeMy WebLinkAboutPermit D03-212 - SBP GENERAL PARTNERSHIP - VACANT SPACEVACANT SPACE #539
539 INDUSTRY DRIVE
D03 -212
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 0223400070
Address: 539 INDUSTRY DR TUKW
Suite No:
Tenant:
Name: VACANT SPACE
Address: 539 INDUSTRY DR, TUKWILA WA
DEVELOPMENT PERMIT
Owner:
Name: SBP GENERAL PARTNERSHIP
Address: C/O DELOITTE & TOUCHE, 2235 FARADAY AVE SUITE 0
Contact Person:
Name: ROYCE A. BERG
Address: LPN ARCHITECTS, 3003 80 AV SE
Contractor:
Name: DAVIS SCHUELLER INC.
Address: 2122 164 ST SW, STE 200, LYNNWOOD WA
Contractor License No: DAVISSI105PN
DESCRIPTION OF WORK:
CONSTRUCT 21 LINEAL FEET OF TENANT WALL WITHIN EXISTING TENANT SPACE.
Permit Number: D03-212
Issue Date: 07/25/2003
Permit Expires On: 01/21/2004
Phone:
Phone: 206 230 -6648
Phone: 206 775 -9400
Expiration Date:07 /01/2004
Value of Construction: $ $1,000.00 Fees Collected: $68.44
Type of Fire Protection: N/A Uniform Building Code Edition: 1997
Type of Construction: VN Occupancy per UBC: 0016
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone: N
Hauling: N Start Time: End Time:
Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation: N
Moving Oversize Load: N Start Time: End Time:
Sanitary Side Sewer: N
Sewer Main Extension: N Private: N
Storm Drainage: N
Street Use: N Profit: N
Water Main Extension: N Private: N
N
Water Meter:
doc: Devperm
D03 -212
Public: N
Non - Profit: N
Public: N
Printed: 07 -25 -2003
Signature
Print Name:
doc: Devperm
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Permit Center Authorized Signature:
A ' JcMes
7,42- t- 'N
I hereby certify that I have read and examined t permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
D03 -212
Date:
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or the p-rfor ance of work. I am authorized to sign and obtain this development permit.
Date: 7' 75.o
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
Printed: 07 -25 -2003
re
-J C.)
00 '
N
CO
�H
CO W
w O
u_ =
= W
z F.
0 .
z F-
U 0.
O — ..
O I-•
W • W
O
.Z
W
i= _ .
0 F-
z
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 0223400070
Address: 539 INDUSTRY DR TUKW
Suite No:
Tenant: VACANT SPACE
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division.
3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical
work will be inspected by that agency (206- 835 - 1111).
4: All mechanical work shall be under separate permit issued by the City of Tukwila.
5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any
construction. These documents are to be maintained and available until final inspection approval is granted.
6: Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3.
7: Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length.
8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997
Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition).
9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be
construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any
other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this
code shall be valid.
10: ** *FIRE DEPARTMENT CONDITIONS * **
PERMIT CONDITIONS
Permit Number: D03 -212
Status: ISSUED
Applied Date: 07/18/2003
Issue Date: 07/25/2003
11: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following
concerns:
12: ** *FIRE EXTINGUISHERS * ** - UFC Article 10 and NFPA 10.
13: The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000
sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to
any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1)
14: Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or
wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with
the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more
than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less
than 4 inches.
15: Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be
identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 106.3) (UFC Standard
doc: Conditions
D03 -212
Printed: 07 -25 -2003
: r ;st`it >l, v'r,�.�3;u {�.+�t.7 i��i`;�"aie; ".t'J3ea�yw'4.iFS" •
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
10 -1)
16: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5)
17: * ** EXITS * ** - UFC Article 12
18: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors
shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of
an approved type. (UFC 1207.3)
19: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212)
20: When two or more exits from a story are required, exit signs shall be installed at the required exits and where
otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2)
21: All exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 1
1/2 hours in case of primary power loss, the exit signs shall also be connected to an emergency electrical system
provided from storage batteries, unit equipment or an on site generator set, and the system shall be installed in
accordance with the electrical code. (UBC 1003.2.8.5)
22: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may
require relocating and /or adding automatic fire detectors.
23: Maintain fire alarm system audible /visual notification. Addition /relocation of walls or partitions may require
relocation and /or addition of audible /visual notification devices.
24: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC
1001.3)
25: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70)
26: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance
#1900 and #1901)
27: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
28: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work.
Signature: i- /
doc: Conditions
4.mq
D03 -212
Date: 7' � , 10 2 )
Printed: 07 -25 -2003
tl:uaS «aas.�
CITY OF TUKWILA -
Community Development uepartment
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print* *
King Co Assessor's Tax No.: 612 2340 CO 0 7 0
Suite Number: 5 3 (I Floor: I
Tenant Name: • : VA G AKr New Tenant: .... Yes CZ ..No
Site Address: 5 3 '7 hype/577r pRlf/E
Property Owners Name: S 13 P P
Mailing Address: ( 7 INDUSTRY PerVE
Name:
Mailing Address:
E -Mail Address:
Contact Person:
E -Mail Address:
Company Name:
Mailing Address:
Contact Person:
.r
•
_ 1
P
3003 BQrH 4VE. S.
u
;:GENERAL CONTRACTOR INFORMATION.;
KfG4.( Sr.c- O L.E2..
P; Arar.HIT - <T pt,A1,1■ER
O
gc z- A. 5ga4
VC
TUKWIt.
cit
City State
City
S L.N.I17
WA '18188
State Zip
Day Telephone: 2.0a- 230 - 6 6 4
[t�I EIeCE.1Z (SLAt,(D WA 4 1ao4 -!a
Zip
Fax Number: z. 0 a - z 30 - c0 04'7
Company Name: DAVIS S GH vac. LgiZ
Mailing Address: 2, X 2 2. 1G41 - p-i s -y' S.W. SUITE. 2.0 0 L-YFI qW ooD WA °160
City State Zip
Day Telephone: 5- 775_ 9 4 oc
Fax Number: 42.5 787- SZO (
Contractor Registration Number: pA /T ST 1 5 pu Expiration Date: 7 -1- 0 4
* *An original or notarized copy of current Washingto S tate Contractor License must be presented at the time o permit issuance **
ARCHITECT'OF RECORD All plans must be *et stamped by A'rctiitectof Reeoird:
.-.-.•
�' •
State
Zip
O
Day Telephone: Z04— 2,.3 n -6 6 4 g
E -Mail Address: en,l a 1 ( (p ii .rc. )? t. Gowe Fax Number: 20 6 230 -66 47
:ENGINEER OF RECORD = All plans must be stamped by . Engineer . Of Record
Company Name:
Mailing Address:
Zip
Contact Person:
E -Mail Address:
\applications \permit application (3 - 2003)
3/2003
N.A
Page 1
State
City
Day Telephone:
Fax Number:
„ pill
Valuation of 't (court dtor s' i price): $ 1 C) 00 . Existing Building Valuation: $ - , d .° Cr
Scope of Work (please provide detailed information): C ot�157CZUC7' Z 1 4-.t NEA4, PEE 07- Tt;1.1.Akt'j'
4pplications \permit application (3•2003)
3/2003
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑.. Sprinklers
„Automatic Fire Alarm 2§..None
•
ANINS
SS lio•
rekt141,17 '5 PA
Will there be new rack storage? ❑ ..Yes ❑ .. No If "yes ", see Handout No. for requirements.
Provide All Building Areas in Square Footage Below
2°° Floor
. 3t 0 •Floor
Floors
Basement •
Accessory : Structute*
Attached Garage
Detached. Garage
Attached Carport .
Detached Carport'
Covered Deck
Uncovered: Deck.
fro, Zo4
±Z
Addition to
Existing
Structure
•
Type of
Construction
per USC
Type of .
Occupancy per
UBC '::
•g' OFFtc E
PLANNING DIVISION:
Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
i.lo c a t- l E
'< E- It )C1ST 1e tZ
rt.lcA 'KlNGt •
Number of Parking Stalls Provided: Standard:
Compact: . Handicap:
Will there be a change in use? ❑ ....Yes ..No If "yes ", explain:
Page 2
❑ . Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ra. No
If"yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
S E F pre-mit_a_c_op_c_
a pLotemie 1c
Scope of Work (please provide detailed information):
Call before you Dig: 1- 800 -424 -5555
Please refer. to. Public Works Bulletin #1 for fees and estimate sheet:
Water District
0 ...Tukwila 0 ... Water District #125
0 ... Water Availability Provided
Sewer District
0 ...Tukwila 0... ValVue ❑ .. Renton ❑ ...Seattle
0 ...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided
0 ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department.
Submitted with Application (mark boxes which apply):
0 ...Civil Plans (Maximum Paper Size — 22" x 34 ")
0 ...Technical Information Report (Storm Drainage)
0 ...Bond ❑ .. Insurance ❑ .. Easement(s)
Proposed Activities (mark boxes that apply):
0 ...Right -of -way Use - Nonprofit for less than 72 hours
0 ...Right -of -way Use - No Disturbance
❑ ...Construction/Excavation/Fill - Right -of -way
Non Right -of -way
...Total Cut
❑ ...Total Fill
cubic yards
cubic yards
0 ...Sanitary Side Sewer
❑ ...Cap or Remove Utilities
❑...Frontage Improvements
❑ ...Traffic Control
0 ...Backflow Prevention - Fire Protection
Irrigation
Domestic Water
0 ...Permanent Water Meter Size...
0 ...Temporary Water Meter Size..
0 ...Water Only Meter Size
❑ ...Sewer Main Extension Public
❑ ... Water Main Extension Public
FINANCE INFORMATION
Fire Line Size at Property Line
0 ... Water ' ❑ ... Sewer
Monthly Service Billing to:
Name:
Mailing Address:
Water Meter Refund/Billing:
Name:
Mailing Addrpik,
\applications \permit application (3.2003)
3/2003
f
/f
❑ .. Abandon Septic Tank
.. Curb Cut
0 .. Pavement Cut
0 .. Looped Fire Line
r,
WO#
WO#
WO#
Private
Private
Number of Public Fire Hydrant(s)
0 ...Sewage Treatment
❑ .. Highline
0 .. Work in Flood Zone
0 .. Storm Drainage
Page 3
City
...Renton
0 .. Geotechnical Report ❑...Traffic Impact Analysis
0 .. Maintenance Agreement(s) ❑...Hold Harmless
0 .. Right -of -way Use - Profit for less than 72 hours
0 .. Right -of -way Use — Potential Disturbance
0 .. Grease Interceptor
0 .. Channelization
0 .. Trench Excavation
0 .. Utility Undergrounding
0 ...Deduct Water Meter Size "
Day Telephone:
State
Zip
Day Telephone:
.; tr ✓'�:ry�ai,�n'':4�A�i�
Unit Type :'
Qty
Unit Type:
Qty
. Unit Type:
Qty:
; Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit
>= 10,000 CFM
Other Mechanical
Equipment
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood
50+ HP /1,750,000 BTU
Heat/Refrig/Cooling
System
Incinerator - Domestic
Air Handling Unit
<= 10,000 CFM
Incinerator — Comm/Ind
MECI ANICAL'PER INFOI....ATI�/.l� .206=431 =367
;' M'G'R. :l+ • {1_ .∎ +d •; n:�r t ) ;'}..a t^ „!� •
t q,.J +:.•r .r.
F f; ., . {.
Print Name:
Mailing Address:
Indicate type of mechanical work being installed and the quantity below:
I Date App e �
.application permit application (3.2003)
3/2003
30 0 3 90 1 ASE.
I Date Applicatio �ps:
Page 4
MECHANICAL CONTRACTOR INFORMATION 1.4 A
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
Contractor Registration Number: Expiration Date:
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Use: Residential: New .... J Replacement .... fp
Commercial: New .... J Replacement .... Ej
Fuel Type: Electric 0 Gas ....0 Other:
PERMIT APPLICATION`NOTES: -- Applicable:to all perm in t
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as
defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Date: 71$/
Day Telephone: 0-664g
('ft: E (5LAW ' IVA 9 9640
City State Zip
Staff 1 '
TRANSACTION LIST:
ACCOUNT ITEM LIST:
Description
doc: Receipt
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
z
RECEIPT
Parcel No.: 0223400070 Permit Number: D03-212 v v 0
Address: 539 INDUSTRY DR TUKW Status: PENDING w o
Suite No: Applied Date: 07/18/2003
Applicant: VACANT SPACE Issue Date: - H .
U) U.
WO }}
Receipt No.: R03 -00864 Payment Amount: 68.44 u.
Initials: SKS Payment Date: 07/18/2003 03:02 PM H w
User ID: 1165 Balance: $0.00 z H
1— O
z i—
t 1 1 Lu
Payee: LPN ARCHITECTS & PLANNERS P.S., INC. 0 N
O
a 1-
W
H —
Type Method Description Amount LL, F-
O :
Payment Check 19721 68.44
...;:Z CI
W
='
O F-
z
BUILDING - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
Account Code Current Pmts
000/322.100
000/345.830
000/386.904
38.75
25.19
4.50
Total: 68.44
X 07/21 9716 TOTAL 6;f1
Printed: 07 -18 -2003
Proje
Type of In,3p cation: '
A dr 3 /6
/,.
Date Cal ed
Special Instructions: ,
4
' R DD
Date Want -z-6,3 d: f as m
`gym.
(
Requester
Requester
Phone No: 6
�/vs' - - 3 .sd - -- 2 i /7
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERM
( 06)431 -3670
Approved per applicable codes. J Corrections required prior to approval.
COMMENTS:
vini4 (0 v 1-e -
Date:
c)(_,..,1 U
E x47.00 REINSPECTION FEE REQ IRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
Project: ,Q ..
- Ty ff Inspection:
Ad ess: ,,,,�
39 ;vrx(5T,z�) ,
Date Call�,d 7-'-C23
r
Special Instructions:
Date Want: n
r - 6 --- 0 3
.�a.m._
p.m.
Requester:D
/T ! 1)
Phpne No:.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100,■Tukwila, WA 98188
PERMIT
(206)431- 670
OMMENTS:
A pproved per applicable codes. a Corrections required prior to approval.
E1 $47.00 REINSPECTIb)d FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 South nter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
41 ' t 4 47P') Vic, 7 : h7 iPC4 . .. '." V " 14 7 Ve 7 :11' ' 1 7 1! 77
'4 A0
Needs shift inspection
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre-Fire:
Permits:
AutliOrZzed Signature
City of Tukwila
Fire Department Thomas P Keefe, Fire Chief
FINALAPP.FRM Rev. 2/19/98
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Project Name / re' • r r /IA /t
Address 7 1 y
Approved without correction notice
Approved with correction notice issued
,-Retain current • in§pection schedule .
Permit No.
Steven M. Mullet, Mayor
Date
Suite #
T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439
ACTIVITY NUMBER: D03 -212
PROJECT NAME: VACANT SPACE
SITE ADDRESS: 539 INDUSTRY DRIVE
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
DEPARTMENTS:
Building ! vision PE
Public Works niA- A2-o3
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07 -22 -03
Complete
Documents /routing slIp.doc
2-28-02
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
5 ( C
Fire Prevention C
Structural ❑
Incomplete
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route , LJ T � , ' / Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
PERMIT COORD COPY
DATE: 07 -18 -03
Revision # After Permit Is Issued
Planning Division L]
Permit Coordinator
DUE DATE: 08 -19 -03
Not Applicable ❑
DATE:
e.yii'f >a� : , ,.?ftie • ���.�. • , ..4.
• 1
07/25/03 15:20 FAX 2062306647 LPN ARCHITECTS
07/25/2003 15119 42578757 DAVIS SCHIJELLER NC
R AS . PROVIDED BY LAW AS;
CANST _ c9N' , GENERAL DA 111 S S 1i°5 FN
•, � . W 1 •d' y
�.. _ f- y . t, r y., -. • 1 � �, _ . 1 .... U� ���� - r '�11 Al ..h:
e•j ,
• . ., `q -
:•• ' . • r ' • • DKVT $ F_TELlaR : 1,
' • " "2122 .164•TE' ST -SW., 'STE '2200'" •
• _ ,•, LYNNWOCD:34- ••;81
• • • ,
•
' bated this 25th day
•
•
• •
. • +' . t. t• "tr :. ••` : • •
.
Datich Abd Display Certilcstt.
of• July, , 2003.
1 ,1.
Notary Public in. - or t e State of WA
•
•
• - 7// /es
•
s .. �i� �arr
• *;
TAO
0.
•
OFw
r � r. , •,0.0.00.,
j ' .1 • ti a.t ' ry' •s1 •
Z002
PAGE 02
LICENSE DETAIL INFORMATION Form Page 1 of 2
Current Filter: None
STATE OF WASHINGTON
DEPARTMENT OF LABOR AND INDUSTRIES
Specialty Compliance Services Division
P. O. Box 44000 Olympia, WA 98504 -4000
THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS:
LICENSE DETAIL INFORMATION
Registration# or License DAVISSI105PN
Name DAVIS SCHUELLER INC
Address 2122 164TH ST SW, STE 200
Address
City LYNNWOOD
State WA
Zip 98037
Phone Number 4257759400
Effective Date 10/15/1990
Expiration Date 7/1/2004
Registration Status ACTIVE
Type CONSTRUCTION CONTRACTOR
Entity CORPORATION
Specialty Code GENERAL
Other Specialties UNUSED
UBI Number 601273797
* *VIEW CROSS REFERENCE FILE FOR THIS LICENSE***
* *VIEW PRINCIPAL OWNER(S) FOR THIS LICENSE* * *
* *VIEW CONTRACTOR BOND /SAVINGS INFORMATION
* * VIEW CONTRACTOR INSURANCE INFORMATION * * *
* **
* *CHECK INQUIRY FOR SUMMONS AND COMPLAINTS* * *
New inquiry by CITY , NAME , PRINCIPAL OWNER NAME , LICENSE , UBI
NUMBER , check the
L &I Contractor Industrial Insurance Premium Status or return to the L &I Construction
Compliance Home Page
https : / /wws2.wa.gov /lni/bbip /TF2Form .asp ?License= DAVISSI105PN
07/25/2003
rtiW...v'.i h::n� viauU:tu
LEGAL DESCRIPTION
i
ARCHITECTURE
ni] PLANNING
ROYCE A. BERG, PRINCIPAL
3003 - 80TH AVE SOUTHEAST
MERCER UAW, WA. 9E040
(206)730.6648 FAX 2344647
TAX ACCOUNT NO. — 022340 - 0070 -08
7 ANDOVER INDUSTRIAL PARK #5, LESS SO. 170 FT. IN WIDTH,
LESS UNION PACIFIC RAILROAD OPERATING RIGHT —OF —WAY
Protect:
Subject:
ANDOVER EXECUTIVE PARK
TENANT IMPROVEMENTS
LEGAL DESCRIPTION
Project No.: 03070 octe:717 -03 B RAJ
AEP- T1.dwg 07/17/2003 09 an
EXHIBIT.
1
Sheet 1 OF 1
�� le`. A: 3}:S';tii::.it:3".4:i:u:.:..�,:i eAVl�3a.:�•.�.::+.-:.c :.:.::: u,:e
TRECK DR
I
OM MB
0
EXISTING PARKING
BLDG. 3
PROPrrrY Thr -
INDUSTRY DRIVE
BLDG. 1
TAX ACCOUNT NO. - 022340 - 0070 -08
7 ANDOVER INDUSTRIAL PARK #5, LESS SO. 170 FT. IN WIDTH,
LESS UN:ON PACIFIC RAILROAD OPERATING RIGHT -OF -WAY
LEGAL DESCRIPTION
VICINITY MAP
L J
$ 1b2nd `
1
S 1 ssro SI,
Summed B r
0
Tukwila Pond
PROPERTY LINE
EXISTING PARKING
BLDG. 2
co
e
SITE KEY PLAN
T rack
IC
Stra Rtbr Blvd _
1
c
I
Umkior Blvd
- TENANT AREA
60'
2
NORTH
NORTH
� RELOC IED EXISTING 2' X 4' LIGHT FIXTURE
L PROPOSED 2' X 4' NIGHT UGHT FIXTURE
PROPOSED NEW 2' X 4' JGHT FIXTURE
PROPOSED NEW 1' X 4' UGHT FIXTURE
PROPOSED 2' X 2' LIGHT FIXTURE
0 RECESSED DOWIvLIGHT
CEIUNG DIFFUSER
ci
0
E
EXIT SIGN
EXISTING TO REMAIN
NOTE: THE ABOVE SYMBOLS ARE USED ON "T"
SHEETS, REF. CONSULTANTS SYMBOLS FOR
THEIR RESPECTIVE DWGS.
9 GENERAL NOTES
CEIUNG RETURN
EXHAUST REGISTER
SPRINKLER HEAD
DUPLEX OUTLET AT 15" A.F.F
FOURPLEX OUTLET AT 15" A.F.F
DEDICATED DUPLEX OUTLET AT 15" A.F.F
DEDICATED FOURPLEX OUTLET AT 15" A.F.F
FLOOR MOUNTED OUTLET
DUPLEX OUTLET AT 42" A.F.F
COMPUTER \DATA OUTLET AT 15" A.F.F
FLOOR MOUNTED COMPUTER \DA.TA OUTLET
TELEPHONE AT 15" A.F.F
FLOOR MOUNTED TELEPHONE
DATA /PHONE OUTLET
LIGHT TOGGLE SWITCH AT 42" A.F.F
3 -WAY LIGHT TOGGLE SWITCH
TYPICAL SPACING FOR ADJ. WALL OUTLETS
1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO WASHINGTON
STATE WAC 51 -40 ACCESSIBILITY REGULATIONS, THE 1997 UNIFORM
BUILDING, MECHANICAL, AND ELECTRICAL CODES AND LOCAL CODES
OR MOST RECENTLY ADOPTED EDITION OR ADOPTED AMENDMENTS
TO THE WASHINGTON STATE ENERGY CODE.
2. TYPICAL DETAILS SHALL APPLY WHERE NO SPECIFIC DETAILS ARE GIVEN.
3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND
CONDITIONS PRIOR TO CONSTRUCTION.
4. ALL DIMENSIONS ARE TO TAKE PRECEDENCE OVER SCALE SHOWN ON
PLANS, ELEVATIONS, SECTIONS, AND DETAILS.
5. ALL EXIT DOORS TO BE OPERABLE FROM INSIDE BUILDING WITHOUT KEYS
OR SPECIAL KNOWLEDGE.
6. OWNER AND CONTRACTOR TO DETERMINE EXTENT OF TENANT IMPROVEMENT
WORK AS RELATED TO SHELL CONSTRUCTION WHERE NOT SPECIFICALLY
DEFINED ON THE DRAWINGS.
7. WALLS ARE TO BE FIRESTOPPED PER UBC SECTION 708.
8. FIRE EXTINGUISHERS SHALL BE PROVIDED PER NFPA #10. HOSE STATIONS
TO BE LOCATED PER LOCAL AGENCY REQUIREMENTS. PROVIDE (1)
2A:10B: C FIRE EXTINGUISHER PER 3,000 S.F. OR 75' TRAVEL DISTANG :.
EXTINGUISHERS HAVING A GROSS WEIGHT NOT EXCEEDING 40 POUNDS
SHALL BE INSTALLED SO THAT THE TOP OF THE EXTINGUISHER IS NOT MORE
THAN 54" ABOVE THE FLOOR, PER UBC 1105.4.8 & NFPA # 10, 1.69.
9. ALL INTERIOR WALL COVERING MATERIALS SHALL BE FIRE RESISTIVE OR
SHALL BE TREATED TO BE FIRE RESISTIVE, SO AS TO RESULT IN A FLAME
SPREAD RATING OF AT LEAST CLASS III FOR GENERAL AREAS, CLASS II
FOR EXITWAYS, AND CLASS I FOR ENCLOSED VERTICAL EXITWAYS.
DELIVER CERTIFICATE TO THE LOCAL FIRE DEPARTMENT.
10. ALL INTERIOR WALLS ATTACHED TO SUSPENDED CEILING SYSTEMS TO
MEET THE REQUIREMENTS OF UBC SECTION 1605. & 1611.
11. PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS ARE TO BE
FIRE STOPPED PER UBC SECTION 709.6.
12. PENETRATIONS IN FLOORS AND CEILINGS REQUIRING PROTECTED
OPENINGS ARE TO BE FIRESTOPPED PER UBC SECTION 710.
13. WOOD USED IN PERMANENT PARTITIONS OF NONCOMBUSTIBLE CONSTRUCTION
SHALL HAVE FIRE RETARDANT TREATMENT PER UBC TABLE 6 -A, NOTE #2
14. ALL EQUALS TO BE SUBMITTED TO ARCHITECT FOR REVIEW PRIOR TO
CONSTRUCTION.
15. BID DESIGN WORK TO BE REVIEWED BY ARCHITECT PRIOR TO CONSTRUCTION.
16. SUBMIT AS -BUILT DRAWINGS FOR PLUMBING, MECHANICAL, ELECTRICAL
AND SPRINKLER.
17. EXIT CORRIDORS TO BE MAINTAINED DURING CONSTRUCTION OF EACH PHASE.
18. INSTALL SPRINKLERS ACCORDING TO DRAWINGS APPROVED BY LOCAL FIRE
MARSHAL.
19. EXITS SHALL BE ILLUMINATED ANY TIME THE BUILDING IS OCCUPIED,
WITH LIGHT HAVING INTENSITY OF NOT LESS THAN 1 FOOT- CANDLE AT
FLOOR LEVEL. FIXTURES REQUIRED FOR EXIT ILLUMINATION SHALL BE
SUPPLIED FROM SEPARATE SOURCES OF POWER AND BE PROVIDED
WITH AN EMERGENCY SYSTEM. UBC SEC. 1003.2.9. EMERGENCY
SYSTEMS SHALL BE SUPPLIED FROM STORAGE BATTERIES OR AN ON
SITE GENERATOR. UBC SEC. 1003.2.9.2
20. ELECTRIC RESISTANCE HEAT IS NOT ALLOWED.
O KEYNOTE
KD REUTE NUMBER
DOOR NUMBER
I 101
F.E.
SYMBOLS
TENANT AREA:
SUITE 539A
SUITE 539
SECTION OR DETAI NUMBERS
DETAIL - SECTION OR TARGET
DRAWING *MERE SECTION OR DETAIL
IS DRAWN
PARTIAL OR FULL SECTION
TALL OR DETAIL SECTIONS
INTERIOR FINISHED WALL ELEVATIONS
GRID LINES - COLUMN
IROOM NUMBER
FIRE EXTINGUISHER
SEE SPECIFICATIONS
EXISTING WALL TO REMAIN
STUD & DRYWALL W,/ SOUND pATT INSULATIQN
25 GA. STEEL STUDS AT 2 -0 O.C.
5/8" GWB EACH SIDE UP TO CEILING. U.O.N.
CODE REFERENCE 1997 UNIFORM BUILDING CODE
WI WA. ST. AMEND.
JURISDICTION TUKWILA, WASHINGTON
SEISMIC ZONE 3
CONSTRUCTION TYPE V - N
OCCUPANCY GROUP
B, OFFICE
S, WAREHOUSE
NUMBER OF FLOORS 1 + MEZZANINE
GROSS BUILDING AREA ±20,204 S.F.
BUILDING 3
±2,500 S.F.
±1,600 S.F.
AREA OF WORK ±21 L.F.
PARKING PROVIDED
NO CHANGE TO EXISTING
DESCRIPTION OF WORK
- CONSTRUCT NEW TENANT WALL WITHIN EXISTING
OFFICE SPACE ±21' -0" L.F. x ±8' -0" HT.,
WORK IS TO RESTORE CHANGES MADE BY
PRIOR TENANT
CODE DATA
*11"r REVVSIO S T O UR Of V4214%, VACHOLIT PII
(," r ROVE
T HE SCOPE F 11., 'I 5 % M 110101"1"4.
�+. pos Woo
4v�
A C.T ACOUSTICAL CEILING TE E
A c F. A1304 rsnwED FLOOR
ALUM_ k;Al m
ASSH. ASPHAL'
MOO. ANODIZEC
B. BEAM
BC. BOARD
Bop. $UILDINC
BLX G. BLOCKING
B.U.R. BUILT UP ROOFING
CLG. CEIUNG
t CENTER LINE
COL COLUMN
CONC. CONCRETE
CONST. CONSTRICTION
CONT. CONTINL OUS
CLSR. CLOSER
DRINKINC FOUNTAIN
DTTL. DETAIL
DIA.(0) DIAMETER
DIM. DIMENSION
D.S. DOWNSPOUT
DR. DOOR
DWG. DRAWING
E.F. EXHAUST AN
E.I.F.S. EXT. INS'JL. FINISH SYSTEM
ELEC. ELECTRIC
ELEV. ELEVATiCN
ENG. ENGINEE
EQ. EQUAL
EQUIP. EO'.JIPMEN"
EXIST. EXISTING
EXP. EXPANSIJN
XT. XTE RIE;
..W C ELLCTRI WATER COOLER
FAR. FLOOR AREA RATIO
F.E. FIRE E)CINGI:ISHER
F.G.C. FIRE EXTINGUISHER CABINET
FAC.FIN. FACTORY FINISH
F.D. OOR i:RA1N
F.D.C. FRE DEPT. CONNECTION
FT. FEET
F.F. F'NISHEG FLOOR
F.H. FIRE HYDRANT
FIN. FINISH
FL FLASHING
FLR. FLOOR
FTC. FOOTING
FDN. FOUNDATION
F.O.C. FACE OF CONCRETE
F.O.F. FACE OF FRAMING
F.R.P. FIBER REINFORCED PLASTIC
GA. GAUGE
GALV. GALVANIZED
GL GLASS
G.L.B. GLU- LAMINATED BEAM
GYP. GYPSUM
G.W.B. GYPSUM WALL BOARD
G.F.I.C. GROUND FAULT INTERUPT CIRCUIT
H.P. HIGH POINT
H.P.S. HIGH PRESSURE SODIUM
HDWR. HARDWARE
HGT. HEIGHT
HCP. HANDICAP
HR. HOUR
HORIZ. HORIZONTAL
H.B. HOSE BI38
ABBREVIATIONS
PROJECT:
SITE ADDRESS 539 INDUSTRY DRIVE
TUKWILA, WASHINGTON 98188
CLIENT
ARCHITECT
CONSULTANTS
Na
T -1
I understand that the Plan Check approvals are
subject to errors and omissions and approval of
plans does not authorize the violation of any
adopted code or ordinance. Receipt of con-
tractor's copy of approved plans acknowledged.
SHEET INDEX
P SSUL
JT
TNT.
Jr
LAY
MFR_
MATS.
MAX.
MECH.
MT_
MIN
MIX
N. c
NO.)
N.I. .
OFF_
O.C.
O.F.L.
O.P.
OPNG.
PNL
PIN.
P LAM.
PLYWD.
P&P
F.L.
R.B.
REC.
RECP.
REINF.
P.D.
M.
EFL.
SHT.
SDG.
S.F.
S.O.G.
SPEC
STD.
STL.
STRUCT.
S &■ .
TELE.
TEMP.
T.
T.J.P.
T" P.
T.I.
T.W.C.
U.O.N.
V.C.T.
V.W.C.
VENT.
VERT.
W.C.
W.COV.
W.H.
W.R.
WD.
RtOR (IN$'J�AT10N
JOIST
LAVATORY
MANUFACTUREP
!MATERIAL
MAXIMUM
MECHA!vICQ
META.
MINIMUM
MiYTURE
NOT TO SCALE
NUMBER
NOT IN CONTRACT
OFFICE
ON CENTER
OVERFLOW LEADER
OPERABLE
OPENIN::
PANL
PARTI r ION
PLATE
PLASTIC L4MINA.Ti-
PLYWOOD
'PROPERTY LINE
PATCH AND PAINT
RAIN LEADER
RUBBER BASE
RECEPTION
RECEPTACLE
REINFORCING
ROOF DRAIN
ROOM
REFLECTED
SIDING
SQUARE FEET
SLAB ON GRADE
SPEC CF ICATION
STANDARD
STEEL
STRUCTURAL
STAIN AND VARNISH
TELEPHONE
TEMPERED
TOILET
TOP OF PARAPET
TYPICAL
TENANT IMPROVEMENT
TACKABLE WALL COVERING
UNLESS OTHERWISE NOTED
VINYL COMPOSITION TILE
VINYL WALL COVERING
VENTILATE
VERTICAL
WATER CLOSET
WALL COVERING
WATER HEATER
WATER RESISTANT
WOOD
WINDOW
ANDOVER EXECUTIVE PARK, BUILDING 3
OWNER SBP GENERAL PARTNERSHIP
617 INDUSTRY DRIVE
TUKWILA, WASHINGTON 98188
MARTIN SMITH INC.
83 SOUTH KING STREET, SUITE 606
SEATTLE, WA. 98104
PHONE: (206) 682 -3300
FAX: (206) 340 -1283
MARK H. ASTOR
LPN ARCHITECTS AND PLANNERS
3003 - 80TH AVE. S.E.
MERCER ISLAND, WA 98040
PHONE: (206) 230 -6648
FAX: (206) 230-6647
ROYCE A. BERG
AESCRIPTION
PROJECT DATA, SITE
PLAN & VICINITY MAP
T-2 TENANT PLAN, WALL DETAIL
SEPARATE PERMIT
R :..%UIRED FOR:
�M CHANICAL
?ELECTRICAL
ge'L.UMBING
[GAS PIPING
CITY OF TUKWILA
BUILDING DIVISION
iO3-212.
3
2
EXI
NO DESCRIPTION DATE
BLDG. PERMIT SUBM.
7 -18 -03
PROJECT DATA,
SITE PLAN &
VICINITY MAP
RECEIVED
CITY OF TUKWILA
JUI_ 18 2003
PERMIT CENTER
File: 03070 /AEP- T1.DWG
JOB NO.: 03070 SHEET
NO OF:
DATE : 07/14/03
DRAWN: RAJ T
CHECK:
TRECK DR
I
OM MB
0
EXISTING PARKING
BLDG. 3
PROPrrrY Thr -
INDUSTRY DRIVE
BLDG. 1
TAX ACCOUNT NO. - 022340 - 0070 -08
7 ANDOVER INDUSTRIAL PARK #5, LESS SO. 170 FT. IN WIDTH,
LESS UN:ON PACIFIC RAILROAD OPERATING RIGHT -OF -WAY
LEGAL DESCRIPTION
VICINITY MAP
L J
$ 1b2nd `
1
S 1 ssro SI,
Summed B r
0
Tukwila Pond
PROPERTY LINE
EXISTING PARKING
BLDG. 2
co
e
SITE KEY PLAN
T rack
IC
Stra Rtbr Blvd _
1
c
I
Umkior Blvd
- TENANT AREA
60'
2
NORTH
NORTH
� RELOC IED EXISTING 2' X 4' LIGHT FIXTURE
L PROPOSED 2' X 4' NIGHT UGHT FIXTURE
PROPOSED NEW 2' X 4' JGHT FIXTURE
PROPOSED NEW 1' X 4' UGHT FIXTURE
PROPOSED 2' X 2' LIGHT FIXTURE
0 RECESSED DOWIvLIGHT
CEIUNG DIFFUSER
ci
0
E
EXIT SIGN
EXISTING TO REMAIN
NOTE: THE ABOVE SYMBOLS ARE USED ON "T"
SHEETS, REF. CONSULTANTS SYMBOLS FOR
THEIR RESPECTIVE DWGS.
9 GENERAL NOTES
CEIUNG RETURN
EXHAUST REGISTER
SPRINKLER HEAD
DUPLEX OUTLET AT 15" A.F.F
FOURPLEX OUTLET AT 15" A.F.F
DEDICATED DUPLEX OUTLET AT 15" A.F.F
DEDICATED FOURPLEX OUTLET AT 15" A.F.F
FLOOR MOUNTED OUTLET
DUPLEX OUTLET AT 42" A.F.F
COMPUTER \DATA OUTLET AT 15" A.F.F
FLOOR MOUNTED COMPUTER \DA.TA OUTLET
TELEPHONE AT 15" A.F.F
FLOOR MOUNTED TELEPHONE
DATA /PHONE OUTLET
LIGHT TOGGLE SWITCH AT 42" A.F.F
3 -WAY LIGHT TOGGLE SWITCH
TYPICAL SPACING FOR ADJ. WALL OUTLETS
1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO WASHINGTON
STATE WAC 51 -40 ACCESSIBILITY REGULATIONS, THE 1997 UNIFORM
BUILDING, MECHANICAL, AND ELECTRICAL CODES AND LOCAL CODES
OR MOST RECENTLY ADOPTED EDITION OR ADOPTED AMENDMENTS
TO THE WASHINGTON STATE ENERGY CODE.
2. TYPICAL DETAILS SHALL APPLY WHERE NO SPECIFIC DETAILS ARE GIVEN.
3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND
CONDITIONS PRIOR TO CONSTRUCTION.
4. ALL DIMENSIONS ARE TO TAKE PRECEDENCE OVER SCALE SHOWN ON
PLANS, ELEVATIONS, SECTIONS, AND DETAILS.
5. ALL EXIT DOORS TO BE OPERABLE FROM INSIDE BUILDING WITHOUT KEYS
OR SPECIAL KNOWLEDGE.
6. OWNER AND CONTRACTOR TO DETERMINE EXTENT OF TENANT IMPROVEMENT
WORK AS RELATED TO SHELL CONSTRUCTION WHERE NOT SPECIFICALLY
DEFINED ON THE DRAWINGS.
7. WALLS ARE TO BE FIRESTOPPED PER UBC SECTION 708.
8. FIRE EXTINGUISHERS SHALL BE PROVIDED PER NFPA #10. HOSE STATIONS
TO BE LOCATED PER LOCAL AGENCY REQUIREMENTS. PROVIDE (1)
2A:10B: C FIRE EXTINGUISHER PER 3,000 S.F. OR 75' TRAVEL DISTANG :.
EXTINGUISHERS HAVING A GROSS WEIGHT NOT EXCEEDING 40 POUNDS
SHALL BE INSTALLED SO THAT THE TOP OF THE EXTINGUISHER IS NOT MORE
THAN 54" ABOVE THE FLOOR, PER UBC 1105.4.8 & NFPA # 10, 1.69.
9. ALL INTERIOR WALL COVERING MATERIALS SHALL BE FIRE RESISTIVE OR
SHALL BE TREATED TO BE FIRE RESISTIVE, SO AS TO RESULT IN A FLAME
SPREAD RATING OF AT LEAST CLASS III FOR GENERAL AREAS, CLASS II
FOR EXITWAYS, AND CLASS I FOR ENCLOSED VERTICAL EXITWAYS.
DELIVER CERTIFICATE TO THE LOCAL FIRE DEPARTMENT.
10. ALL INTERIOR WALLS ATTACHED TO SUSPENDED CEILING SYSTEMS TO
MEET THE REQUIREMENTS OF UBC SECTION 1605. & 1611.
11. PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS ARE TO BE
FIRE STOPPED PER UBC SECTION 709.6.
12. PENETRATIONS IN FLOORS AND CEILINGS REQUIRING PROTECTED
OPENINGS ARE TO BE FIRESTOPPED PER UBC SECTION 710.
13. WOOD USED IN PERMANENT PARTITIONS OF NONCOMBUSTIBLE CONSTRUCTION
SHALL HAVE FIRE RETARDANT TREATMENT PER UBC TABLE 6 -A, NOTE #2
14. ALL EQUALS TO BE SUBMITTED TO ARCHITECT FOR REVIEW PRIOR TO
CONSTRUCTION.
15. BID DESIGN WORK TO BE REVIEWED BY ARCHITECT PRIOR TO CONSTRUCTION.
16. SUBMIT AS -BUILT DRAWINGS FOR PLUMBING, MECHANICAL, ELECTRICAL
AND SPRINKLER.
17. EXIT CORRIDORS TO BE MAINTAINED DURING CONSTRUCTION OF EACH PHASE.
18. INSTALL SPRINKLERS ACCORDING TO DRAWINGS APPROVED BY LOCAL FIRE
MARSHAL.
19. EXITS SHALL BE ILLUMINATED ANY TIME THE BUILDING IS OCCUPIED,
WITH LIGHT HAVING INTENSITY OF NOT LESS THAN 1 FOOT- CANDLE AT
FLOOR LEVEL. FIXTURES REQUIRED FOR EXIT ILLUMINATION SHALL BE
SUPPLIED FROM SEPARATE SOURCES OF POWER AND BE PROVIDED
WITH AN EMERGENCY SYSTEM. UBC SEC. 1003.2.9. EMERGENCY
SYSTEMS SHALL BE SUPPLIED FROM STORAGE BATTERIES OR AN ON
SITE GENERATOR. UBC SEC. 1003.2.9.2
20. ELECTRIC RESISTANCE HEAT IS NOT ALLOWED.
O KEYNOTE
KD REUTE NUMBER
DOOR NUMBER
I 101
F.E.
SYMBOLS
TENANT AREA:
SUITE 539A
SUITE 539
SECTION OR DETAI NUMBERS
DETAIL - SECTION OR TARGET
DRAWING *MERE SECTION OR DETAIL
IS DRAWN
PARTIAL OR FULL SECTION
TALL OR DETAIL SECTIONS
INTERIOR FINISHED WALL ELEVATIONS
GRID LINES - COLUMN
IROOM NUMBER
FIRE EXTINGUISHER
SEE SPECIFICATIONS
EXISTING WALL TO REMAIN
STUD & DRYWALL W,/ SOUND pATT INSULATIQN
25 GA. STEEL STUDS AT 2 -0 O.C.
5/8" GWB EACH SIDE UP TO CEILING. U.O.N.
CODE REFERENCE 1997 UNIFORM BUILDING CODE
WI WA. ST. AMEND.
JURISDICTION TUKWILA, WASHINGTON
SEISMIC ZONE 3
CONSTRUCTION TYPE V - N
OCCUPANCY GROUP
B, OFFICE
S, WAREHOUSE
NUMBER OF FLOORS 1 + MEZZANINE
GROSS BUILDING AREA ±20,204 S.F.
BUILDING 3
±2,500 S.F.
±1,600 S.F.
AREA OF WORK ±21 L.F.
PARKING PROVIDED
NO CHANGE TO EXISTING
DESCRIPTION OF WORK
- CONSTRUCT NEW TENANT WALL WITHIN EXISTING
OFFICE SPACE ±21' -0" L.F. x ±8' -0" HT.,
WORK IS TO RESTORE CHANGES MADE BY
PRIOR TENANT
CODE DATA
*11"r REVVSIO S T O UR Of V4214%, VACHOLIT PII
(," r ROVE
T HE SCOPE F 11., 'I 5 % M 110101"1"4.
�+. pos Woo
4v�
A C.T ACOUSTICAL CEILING TE E
A c F. A1304 rsnwED FLOOR
ALUM_ k;Al m
ASSH. ASPHAL'
MOO. ANODIZEC
B. BEAM
BC. BOARD
Bop. $UILDINC
BLX G. BLOCKING
B.U.R. BUILT UP ROOFING
CLG. CEIUNG
t CENTER LINE
COL COLUMN
CONC. CONCRETE
CONST. CONSTRICTION
CONT. CONTINL OUS
CLSR. CLOSER
DRINKINC FOUNTAIN
DTTL. DETAIL
DIA.(0) DIAMETER
DIM. DIMENSION
D.S. DOWNSPOUT
DR. DOOR
DWG. DRAWING
E.F. EXHAUST AN
E.I.F.S. EXT. INS'JL. FINISH SYSTEM
ELEC. ELECTRIC
ELEV. ELEVATiCN
ENG. ENGINEE
EQ. EQUAL
EQUIP. EO'.JIPMEN"
EXIST. EXISTING
EXP. EXPANSIJN
XT. XTE RIE;
..W C ELLCTRI WATER COOLER
FAR. FLOOR AREA RATIO
F.E. FIRE E)CINGI:ISHER
F.G.C. FIRE EXTINGUISHER CABINET
FAC.FIN. FACTORY FINISH
F.D. OOR i:RA1N
F.D.C. FRE DEPT. CONNECTION
FT. FEET
F.F. F'NISHEG FLOOR
F.H. FIRE HYDRANT
FIN. FINISH
FL FLASHING
FLR. FLOOR
FTC. FOOTING
FDN. FOUNDATION
F.O.C. FACE OF CONCRETE
F.O.F. FACE OF FRAMING
F.R.P. FIBER REINFORCED PLASTIC
GA. GAUGE
GALV. GALVANIZED
GL GLASS
G.L.B. GLU- LAMINATED BEAM
GYP. GYPSUM
G.W.B. GYPSUM WALL BOARD
G.F.I.C. GROUND FAULT INTERUPT CIRCUIT
H.P. HIGH POINT
H.P.S. HIGH PRESSURE SODIUM
HDWR. HARDWARE
HGT. HEIGHT
HCP. HANDICAP
HR. HOUR
HORIZ. HORIZONTAL
H.B. HOSE BI38
ABBREVIATIONS
PROJECT:
SITE ADDRESS 539 INDUSTRY DRIVE
TUKWILA, WASHINGTON 98188
CLIENT
ARCHITECT
CONSULTANTS
Na
T -1
I understand that the Plan Check approvals are
subject to errors and omissions and approval of
plans does not authorize the violation of any
adopted code or ordinance. Receipt of con-
tractor's copy of approved plans acknowledged.
SHEET INDEX
P SSUL
JT
TNT.
Jr
LAY
MFR_
MATS.
MAX.
MECH.
MT_
MIN
MIX
N. c
NO.)
N.I. .
OFF_
O.C.
O.F.L.
O.P.
OPNG.
PNL
PIN.
P LAM.
PLYWD.
P&P
F.L.
R.B.
REC.
RECP.
REINF.
P.D.
M.
EFL.
SHT.
SDG.
S.F.
S.O.G.
SPEC
STD.
STL.
STRUCT.
S &■ .
TELE.
TEMP.
T.
T.J.P.
T" P.
T.I.
T.W.C.
U.O.N.
V.C.T.
V.W.C.
VENT.
VERT.
W.C.
W.COV.
W.H.
W.R.
WD.
RtOR (IN$'J�AT10N
JOIST
LAVATORY
MANUFACTUREP
!MATERIAL
MAXIMUM
MECHA!vICQ
META.
MINIMUM
MiYTURE
NOT TO SCALE
NUMBER
NOT IN CONTRACT
OFFICE
ON CENTER
OVERFLOW LEADER
OPERABLE
OPENIN::
PANL
PARTI r ION
PLATE
PLASTIC L4MINA.Ti-
PLYWOOD
'PROPERTY LINE
PATCH AND PAINT
RAIN LEADER
RUBBER BASE
RECEPTION
RECEPTACLE
REINFORCING
ROOF DRAIN
ROOM
REFLECTED
SIDING
SQUARE FEET
SLAB ON GRADE
SPEC CF ICATION
STANDARD
STEEL
STRUCTURAL
STAIN AND VARNISH
TELEPHONE
TEMPERED
TOILET
TOP OF PARAPET
TYPICAL
TENANT IMPROVEMENT
TACKABLE WALL COVERING
UNLESS OTHERWISE NOTED
VINYL COMPOSITION TILE
VINYL WALL COVERING
VENTILATE
VERTICAL
WATER CLOSET
WALL COVERING
WATER HEATER
WATER RESISTANT
WOOD
WINDOW
ANDOVER EXECUTIVE PARK, BUILDING 3
OWNER SBP GENERAL PARTNERSHIP
617 INDUSTRY DRIVE
TUKWILA, WASHINGTON 98188
MARTIN SMITH INC.
83 SOUTH KING STREET, SUITE 606
SEATTLE, WA. 98104
PHONE: (206) 682 -3300
FAX: (206) 340 -1283
MARK H. ASTOR
LPN ARCHITECTS AND PLANNERS
3003 - 80TH AVE. S.E.
MERCER ISLAND, WA 98040
PHONE: (206) 230 -6648
FAX: (206) 230-6647
ROYCE A. BERG
AESCRIPTION
PROJECT DATA, SITE
PLAN & VICINITY MAP
T-2 TENANT PLAN, WALL DETAIL
SEPARATE PERMIT
R :..%UIRED FOR:
�M CHANICAL
?ELECTRICAL
ge'L.UMBING
[GAS PIPING
CITY OF TUKWILA
BUILDING DIVISION
iO3-212.
3
WALL DETAIL
EXISTING SUS'ENDED
CEIUNG SYSTEM
EXISTING METAL FRAMED
SOFFIT W/ GW5
TRACK, ATTACH W/
ANCHORS 0 2' G.C.
SOUND BATT INSULATION TYP.
5/8" GWB EACH
SIDE TYPICAL, PAINT
8" METAL STUDS
0 2' - 0. C., BLDG.
STANDARD BASE TYP.
TRACK, ATTACH W/
ANCHORS C 2' O.C.
OUTLINE OF EXISTING \\_
BUILDING, NO CHANGES
OUTLINE OF EXISTING EXISTING
BUILDING, NO CHANGES \ DOOR
\ --OUTLINE OF EXISTING EXISTING DOOR
BUILDING, NO CHANGES
EXISTING DOOR
DESCRIPTION OF WORK
CONSTRUCT NEW TENANT WALL TO CEILING
WITHIN EXISTING TENANT SPACE
Gl1 Of nab
3 J L 2 4 Z0b3
AN rr , to
OUTLINE OF EXISTING
BUILDING, NO CHANGES
TENANT PLAN
1/8'
1
;MID
EXI
WA
I II
NO DESCRIPTION DATE
BLDG. PERMIT SUBM.
7 -18 -03
TENANT PLAN,
WALL DETAIL
RECEIVED
CITY OF TUKWILA 1
JUL 1 B 2003
PERMIT CLOVER
File: 03070 /AEP— BLDG3.dwg ,-
JOB NO.: 03070 SHEET NO OF:
DATE: 07/14/03
DRAWN: RAJ T-2
CHECK:
WALL DETAIL
EXISTING SUS'ENDED
CEIUNG SYSTEM
EXISTING METAL FRAMED
SOFFIT W/ GW5
TRACK, ATTACH W/
ANCHORS 0 2' G.C.
SOUND BATT INSULATION TYP.
5/8" GWB EACH
SIDE TYPICAL, PAINT
8" METAL STUDS
0 2' - 0. C., BLDG.
STANDARD BASE TYP.
TRACK, ATTACH W/
ANCHORS C 2' O.C.
OUTLINE OF EXISTING \\_
BUILDING, NO CHANGES
OUTLINE OF EXISTING EXISTING
BUILDING, NO CHANGES \ DOOR
\ --OUTLINE OF EXISTING EXISTING DOOR
BUILDING, NO CHANGES
EXISTING DOOR
DESCRIPTION OF WORK
CONSTRUCT NEW TENANT WALL TO CEILING
WITHIN EXISTING TENANT SPACE
Gl1 Of nab
3 J L 2 4 Z0b3
AN rr , to
OUTLINE OF EXISTING
BUILDING, NO CHANGES
TENANT PLAN
1/8'
1