HomeMy WebLinkAboutPermit D03-326 - SOUTHCENTER MALL - THE LIMITED - REMODELTHE LIMITED 315 SOUTHCENTER MALL D03 -326 z JU 0O N co w J F-. N LL W J: LL Q. w no � W' Z1 O Z w F- np uj 0 D- 0 I-- = U: - ~ O' Li;Z rz 0E- Z Water Main Extension: Water Meter: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049004 Permit Number: D03 -326 Address: 315 SOUTHCENTER MALL TUKW Issue Date: 01/15/2004 Suite No: Permit Expires On: 07/13/2004 Tenant: Name: THE LIMITED Address: 315 SOUTHCENTER MALL, TUKWILA WA Owner: Name: 3G SOUTHCENTER LTD Address: 25425 CENTER RIDGE RD, CLEVELAND OH Contact Person: Name: TIM SCHENK Address: 1120 E 80 ST, SUITE 211, BLOOMINGTON MN Contractor: Name: SHRADER& MARTINEZ CONST INC Address: 2030 W HY 89A STE B2, SEDONA AZ Contractor License No: SHRADMC070BC DESCRIPTION OF WORK: DOWNSIZING EXISTING "THE LIMITED" STORE IN THE MALL. REMODEL INCLUDES FLOORING, WALL CONSTRUCTION, LIGHTING AND CEILING. PORTION OF STORE BEING RETURNED TO MALL. Value of Construction: $ $240,000.00 Fees Collected: $2,937.79 Type of Fire Protection: SPRINKLERS Uniform Building Code Edition: 1997 Type of Construction: II -N Occupancy per UBC: 0023 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N N N Sanitary Side Sewer: N Sewer Main Extension: N Private: N Storm Drainage: N Street Use: N Profit: N DEVELOPMENT PERMIT Private: N D03 -326 Phone: Phone: 1- 800 -541 -0821 Phone: Expiration Date:01 /10/2005 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Public: N Non - Profit: N Public: N Printed: 01 -15 -2004 • [.v�Y r`.aTx3�Sd:w�`.tiw Signature: • doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: doezet. I hereby certify that I have read and examin-d this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. 9 9 �J p //� 9 P p !-C(Kke -e Print Name: cL M C aec, This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 003 -326 Date: / -'/ ar Date: /5 Printed: 01 -15 -2004 doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 2623049004 Permit Number: D03 -326 Address: 315 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 10/22/2003 Tenant: THE LIMITED Issue Date: 01/15/2004 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 4: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 5: All mechanical work shall be under separate permit issued by the City of Tukwila. 6: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 7: Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 8: Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 9: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 10: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 11: There shall be no occupancy of the building(s) until the final inspection has been completed by the Tukwila Building Inspector. 12: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform Building Code and the Washington State Ventilation and Indoor Quality Code, Chapter 51 -13 WAC. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 15: ** *FIRE EXTINGUISHERS * ** - UFC Article 10 and NFPA 10. 16: The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) D03 -326 Printed: 01 -15 -2004 aiSt.kd6t #cn�l'f,+: il�i" t i' ;,:'44 .: 41 4'4 ?7.144.,:41 ..iiv..�s. 2'a�T } 1! City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 17: Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. 18: Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 106.3) (UFC Standard 10 -1) 19: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 43, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not complete, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 21: * ** EXITS * ** - UFC Article 12 22: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) 24: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) 25: When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2) 26: All exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 1 1/2 hours in case of primary power loss, the exit signs shall also be connected to an emergency electrical system provided from storage batteries, unit equipment or an on site generator set, and the system shall be installed in accordance with the electrical code. (UBC 1003.2.8.5) 27: The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of it's failure, illumination shall be automatically provided from an emergency system for Group I, Divisions 1.1. and 1.2 occupancies and for all other occupancies where the means of egress system serves an occupant load of 100 or more. Such emergency systems shall be installed in accordance with the electrical code. (UBC 1003.9.2) 28: * ** SPRINKLER SYSTEMS * ** - UFC ARTICLE 10 - NFPA 13 29: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. 30: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 5.5.3.1) 31: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and doc: Conditions D03 -326 Printed: 01 -15 -2004 a.::xu.esil �rman+P!rSnNna, ,+Fh� - :••.mvmanr ..'«.v.+.�a :vnsl:taRxP /sV'TE?rtAMP) City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 32: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 33: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 34: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature:` . S • = Date: Print Name: �J fricacc.... doc: Conditions D03 -326 Printed: 01 -15 -2004 CITY OF TUKWIL4 Community Development, Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Site Address: 633 SOU'[1- C..er`iree.. 9#04414A-1-. Tenant Name: 114 E u rn _ Property Owners Name:J4EST T-ICcLO CO Q.1?OQATtON Mailing Address: 11:01 t4 (Zlc. QUID 1 2 FLOO(Z• . LOS M4ELc5 CA . 400-4' City State Name: - r usA 5CI -kEN K Day Telephone: 1•-Soo - 541 - O$Z$ Mailing Address: 1120 E • 13 sr. SV !1 21■ • 13•.1000 ur4(rrOrJ Mr-1 SS4I z0 City State Zip E -Mail Address: — l - h ms @_elde.riolne s . corn Fax Number: g5z•8S4 •49 ;,GENERAL: CONTRACTOR- INFORMATION Company Name: SO RADE11- M1 -T1 rIEZ C:ar(STCZ. jCVION Mailing Address: ZO3O (r( . f-1W 83A suire 13 -2 Contact Person: 1sit t 14.c COOK. E -Mail Address: MCOOI,C Ca Shvtadtert v+fnez.con-...., Contact Person: M i (,LE SV L.l..l YAc- ` E -Mail Address: M 5uLi..1Vgr sf1mmsh0ck,COW\ Contact Person: 131t-L. (3E5 r E -Mail Address: \applications \permit application (3 -2003) 3/2003 Page I �.,,.. • .•,....�M; J�f. YA! kt': fY r. Yt' yylfilKSY!< f N�t' 1"• We;#? !ritNiCK�MaFiL }?IF�4�YS',�2 {'R" fig L' �T .3�`i'�'a£P`r�rtitCh?'��4alc:.: din' cirA�7 ^'a4:,- «nt5w°w�;i :- T. ° ^-t �.:. Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** King Co Assessor's Tax No.: 26 Z54 3/4" f07 Suite Number: j 00 New Tenant: 5EOO11Ps A2_ 43633 Company Name: 1.11LL■Awn P. 6sr • W, 14 3 k' COriSVLtP 495 • LTD Floor: 0 ... Yes City State Day Telephone: C2$ • 2$2 Fax Number: Company Name: GEP.Al...D S . SNt2em -IOCL& Aiec44zec s Mailing Address: 6130 S , 5 ZO , Svit"e 1 vo . Co Lvrnevs 01l 430: 1 City State Zip Day Telephone: 6 - S'JS• 4 SSO Fax Number: 614 • SzFS Z..No Zip Zip Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF RECORD. All plans must be Wet' stamped by Architect of Record ENGINEER OF RECORD..- All plans must be wet stamped by Engineer of Record Mailing Address: 11 l G%4A1i0. r1G ' ` 0(ZI'E 1[L€ 014 - 81 City State Day Telephone: 614. 8Z. 1199 Fax Number: Zip �.T.in.ronra.es!,: :w:.e •�;u :nom ;r'r�l+nb«u �rtr hA rrn s r,M.,M >`xi.•H�w✓,» -.WM�4 jtujimprqrwvinjNIFTWATI Valuation of Project (contractor's bid price): $ t w -6®e 1 Scope of Work (please provide detailed information): DONNS /Z.e !Zeal 01 L. Oi= T4 E}CSi SflvIE- ''TkE un t` sroge. in 714 E rnAU ; Will there be new rack storage? El .. Yes .. No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below l 'YFloor. 2 "° Floor 3`0 Floor Floors: .thru `.:Basement Accessory Structure* , Attached Garage' \ Detached Garage Attached ;Carport :Detached Carport::: •Covered•Deck.. Uncovered Deck : 5656 Addition to Existing Structure Type.of Construction per UBC Type of -. Occupancy. per UBC PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks 18 inches and.overhangs greater than d8.inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? O ... :Yes - • • D ..No If' "yes ", explain:. ,. 'applications \permit application (3.2003) 3/2003 FIRE PROTECTION/HAZARDOUS MATERIALS: . g.. Sprinklers - . 'D Fire Alarm ❑..None D . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑..Yes If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 1I paper indicating quantities and Material Safety Data Sheets. Page 2 Existing Building Valuation: $ ,.. 1 • Handicap: ., _r, :.. .. e ..:ty�.::..i'ism,'t•.%�.0 .[3i.:xu�....:C' %l,jr sik'r`q. ,. �iLti;- �t"ti.t�ti.,:u::f.'i}1'.Uy# ii>..Y�,'.�T::. Scope of Work (please provide detailed information): Water District ❑ ...Tukwila 0... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑... ValVue ❑ .. Renton ❑ ...Seattle ❑ ...Sewer Use Ct;rtificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a,current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitary Side Sewer ❑...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size.. ❑...Water Only Meter Size ❑ ...Sewer Main Extension Public _ ❑ ...Water Main Extension Public _ \applications \permit application (3 -2003) 3/2003 Please refer to Works Bulletin #1. for fees and estimate sheet.;:: cubic yards cubic yards „ „ Call before you Dig: 1 -800- 424 -5555 ❑ .. Highline ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ .. Maintenance Agreement(s) ❑...Hold Harmless ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line „ „ WO# WO# WO# Private Private Page 3 ❑ ...Renton ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size " FINANCE INFORMATION Fire Line Size at Property Line ❑ ... Water ❑ ...Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: Number of Public Fire Hydrant(s) ❑...Sewage Treatment Day Telephone: City State Zip Day Telephone: City State Zip iN 1 Unit Type: Qty Unit Type: ' Qty Unit Type:. Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler j VW/is AkrIP VAV 60A Z 1 3 -15 HP /500,000 BTU 15 -30 HP /1,000,000 BTU Floor Furnace Ventilation Fan Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Z Incinerator — Comm/Ind i MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ ) , 4 6,57e00 Scope of Work (please provide detailed information): I eV STALL Z "/Eh/ Al (L. 14ANDL f'C— V41 r.s Z NEW E r P u m a s , 1 V A V rcox I - jrl j t,„r r Ex144 s r FarJ Use: Residential: New .... Replacement .... Commercial: New ....a Replacement .... D Fuel Type: Electric 73, Gas.... J Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE : • WS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 R OR AUTH . GENT. Signature: „ . Dater Z Print Name: Jet 114 F vpiA / C -7' 5e1-)/ Telephone: I - co -0 — Set/ "U 8 Z/ Mailing Address: J / t -C r 5_ [ e}O 7 57-0g7* / 511 2' 7 z Z. I City Date Application Accepted: /D - ZZ -a3 lappliationa‘permit application (3 -2003) ti- eoaii*er' () rnit/' 5 54 Date Application Expires: Slate State Staff Initials: Zip Zip i Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 2623049004 315 SOUTHCENTER MALL TUKW THE LIMITED R03 -01278 SKS 1165 ELDER -JONES TRANSACTION LIST: Type Method Description Payment Check 032737 RECEIPT ACCOUNT ITEM LIST: Description Account Code PLAN CHECK - NONRES 000/345.830 Permit Number: Status: Applied Date: Issue Date: Payment Amount: Payment Date: Balance: Amount 1,155.54 Current Pmts 1,155.54 Total: 1,155.54 D03 -326 PENDING 10/22/2003 1,155.54 10/22/2003 12:05 PM $1,782.25 h vv 4109 10/28 9710 TOTAL 1555.54 Printed: 10 -22 -2003 Z � QQ 2 J U U U U J H SQLL w • ? • d = w z 1- 0 Z w 0 0— O h- ul w I— • U U N H HS 0 z Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: THE LIMITED R03 -01307 SKS 1165 ELDER -JONES TRANSACTION LIST: Type Method Payment Check ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 2623049004 315 SOUTHCENTER MALL TUKW BUILDING - NONRES Description 032737 Account Code 000/322.100 RECEIPT Permit Number: Status: Applied Date: Issue Date: Payment Amount: Payment Date: Balance: Amount 400.00 Current Pmts 400.00 Tota I : 400.00 D03 -326 PENDING 10/22/2003 400.00 10/27/2003 01:20 PM $1,382.25 Printed: 10 -27 -2003 Z Q • re 2 . _ U O ` N0 J v_ W O g J. u. � W Z I— O Z W Lu U � W O Z U - ' O Z Payee: SHRADER & MARTINEZ CONSTRUCTION INC. ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 RECEIPT Parcel No.: 2623049004 Permit Number: D03 -326 Address: 315 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 10/22/2003 Applicant: THE LIMITED Issue Date: Receipt No.: R04 -00030 Payment Amount: 1 Initials: SKS Payment Date: 01/15/2004 10:38 AM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 76548 1,382.25 Account Code Current Pmts 1,377.75 4.50 Total: 1,382.25 67 01 /16 9716 TOTAL. 1302.25 Printed: 01 -15 -2004 doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049004 Address: 315 SOUTHCENTER MALL TUKW Suite No: Applicant: THE LIMITED Receipt No.: R04 -00221 Payment Amount: 47.00 Initials: SKS Payment Date: 02/24/2004 08:49 AM User ID: 1165 Balance: $0.00 Payee: SHRADER & MARTINEZ TRANSACTION LIST: Type Method Description Amount Payment Check 098142 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES RECEIPT Permit Number: D03 -326 Status: ISSUED Applied Date: 10/22/2003 Issue Date: 01/15/2004 47.00 Account Code Current Pmts 000/345.830 47.00 Total: 47.00 3j03 02/26 9 716 TOTAL. 47.00 Printed:. 02 -24 -2004 Pro'e . ' ? e ,i Type of In > ize Add ss• . 3 /.5 ,S� / // Date Called: Special Instructions: Date Wanted: 1 CC- dg p.m. Requester: Phone No: id INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0,3-3 26 (206)431 -3670 COMMENTS: Approved per applicable codes. ❑ Corrections required prior to approval. $47.00 REINSPECTIbN FEE REQUIRED. Prior to inspection, fee roust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: &-• /24? /ZS VA 7 �r S7 //J 0 ,4 ee'Cl 13` On-) /A /l it /` fir° K / zs-� 4 r (1 / , gee , Date Called: 1 Al-- / L1 aY � / 7,4 /G�tig/ -i/ t•Q rig F / )tt/0 / i--Al cd6 /2 0Ale g PW fr, .� INef d 0 a.m. p.m. AfOr6 .* ( - b wi e/e 0I'G-f c) slot_ ,s-id 4 }i-'lh rf A) /ii)dv; /;0vtJ 4 6-44) )2 /.s 1. „ 174 ,i , -f4 45 Sz /r S A✓i' 10Wed. .S. f//hf2l.NeEj L /b/Ti`t/i Tai / / /- e4 L./ Project: Type of Inspection: ` Address: 31 £ sd,-- haeAiIe / nil/ Date Called: 1 Al-- / L1 aY Special Instructions: Date Wanted: 14- 14/ — b 1 a.m. p.m. Request 1 4--C / Phone N : f .0 — ,q. yj - 310 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Approved per applicable codes. r4, pa (206)431 -3670 Corrections required prior to approval. Inspe eceipt No.: 7.00 REINSPE ION FEE REQUIR Date . Prior to inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Projec /� /�j Type of Inspection: tom► . Address: ,14r // Date Called: Special Instructions: Date Wanted: > 3 a.m. Requester: Phone No: INSPECTION 0. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 )4Approved per applicable codes. Corrections required prior to approval. COMMENTS: 40-z cd-tAS 4 -./6 Inspector: Date: El $4 .i ' REINSPECTION F paid at 6300 Southcente REQUIRED. Prior to inspection, fee must be Ivd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: C gJS 12 /1,5 lied >4 a i -.` / //LL � � f � �( / f � Ltf�1_/ i J 12 ?�s a ofrGr 449-+1 o ," /1 2 J( 4 4 / i /" 2 Ot D A 1 e4 AL - n ,4 0 (i-r7 1- 1-- b/- i .I I , - fri-e-7 1 / -C_____ / y-3e%ee Requeste I Pro'ect:. �/ ! �} � / ' 7y / G r /, Type of Inspection: / / / // ., Address: 3/S C / 2 Date Called: -, r . ' — - f 0 `/ �- Special Instructions: Date Wanted: / a.m. 5 - /I -Q y m Requeste Phone No: (' b)2 v/- ?//3 vyx- �h..ttv Approved per applicable codes. Inspector: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PER (206)431 -3670 Corrections required prior to approval. 4 /A7 Date: 3%-- /y-- $47.00 REINSPECTION FEE'ftEQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: / �J �' ,(,t / Type of Inspection: 1 A� X4/.4 , ) Address: 3 / .. r4 -fr/Ir e 9 /i' Date Called: - \) (t' ' ,3 - / U -e" Special Instructions: Date Wanted: 3 _.- /0 .r 041 a.m. p.m. Reques 1. 'eSQE.e Phone No: 0 C Z. y /— 3/ INSPECTION NO. "J.Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Corrections required prior to approval. COMMENTS: (7) b - cf 4./; Ins ector: � R ipt No.: Date: .- / p --Uy x 47 / 00 REINSPECTION FE REQUIRED Prior to inspection, fee must be p IJ at 6300 Southcenter Blvd., Suite 1 0. Call to schedule reinspection. Date: Project: n Q 1 ,-1,4 1 • Jd Type of I pection: • mina. v A Ad s: S C M / Date Called: 3i 0 ,.-- ■ Special�Instructions: Date Wanted:.. '.m Requester: ., ( P. PAL Phone No: _ ,2 r • ,) Li 1.- •... ' 03 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pproved per applicable codes. Corrections required prior to approval. COMMENTS: 23„, /4- Ne C/ J /d) J q nspect . ): Data o9' % .00 REINSPECTIO FEE REQUIR b. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suit 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: !/ J/W.6� C% 0 - 0),1 A 2g4 ins 0-7✓/ , 19 . E -P� ,e ) Re / / )(70 , c / ;2 (,/,,, /1 eiv,.0/, Special Instructions: Date Wanted: E )� i r ( p.m. 1:- 43- ,/1 y, , 4 (? ist- /5 GL4/ / / -W 7/ Pro t p Type of Inspection: , Address Date CIlea: Special Instructions: Date Wanted: E )� i r ( p.m. Requester: t oioAi Phon No : 7 . to -acil 3/03 t! INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Receipt No.: INSPECTION RECORD Retain a copy with permit --? . ,. r.•�t u.%./ El Corrections required prior to approval. Date: 1 47.00 REINSPECTION FEE REQUIRE, Prior to inspection, fee must be paid at 6300 Southcente Blvd., Suite 100. Call to schedule reinspection. Date: Pect: 044/1 Type of In 15ectio • . ddrts -I i Date ie__01 Called: Special Instructions: Date Wante / 1 41 . Requester _ f -'�jJ�} Kibbe No: ° - J.' ti, :ti Fies:ieNu w ;x(+ t.r c aa. ' • .. . INSPECTION NO. INSPECTION RECORD Retain a copy with permit '� J PERM. NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. 0. 431 -3670 COMMENTS: /144,/ t("/).7e _ /, •rte E-��, / Inspector: Date: 3 Corrections required prior to approval. $47.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ProIz Li 1 r Type of.lnspec ion ) (1 ( / f��.� Ad 7 s: I/44 / Date Called: V / 2 pen Instructions: Date Wanted :m. ff Re ueste . q r� � ne, Tre r� a q INSPECTION NO. • INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Do3-- (206)431 -3670 R Approved per applicable codes. Corrections required prior to approval. COMMENTS: A/( yf , Inspector: Date: 3.'/ El $47.00 REINSPECTIO t`EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: .. I (.••j. t t''t'1 f 1G I' T e of Inspectio i 'f - r1.1 rrr'(v itir Address: )5 C.' --y �:, 16k I l Date Called: 1 el = Spec ial Instructions: ' / Date Wanted: 7 / . p.m. Requester: Phone No: -- /,10 --., 211--.3/0 ' , g N? j, + K '°' ' J 1.' INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: fj PT", Inspector: Date: 0$47.00 REINSPECTION iEE REQUIRED. Prior to inspection, fee mus be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: i ,.. Type of Inspection: !/ , Address: 3 ,_,S ( Aa/ Date Call d: Specia s ructions: - Date Wanted: 2......_20z.te9 Requester: Phone No: 7 • • INSPECTION RECORD Retain a copy with permit INSP ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 88 1b3-32.4 )431-3670' K approved per applicable codes. Corrections required prior to approval. COMMENTS: J.1 1.7 Inspector: Iff IlW r r El $47.0 I • EINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: D ,Z ) /c■Al- 7)-1: / t II (` .t__ TL ti.L / �1. ■ S4..0r. 4(1 9 /. --- f / .. D IV 1..4 7' 4 0 4 C 74 ) /? t 1� 1 77 23 / , I - -- 1' - - e‘t 7442, h-- A"---L: s 4,1 // ,, S 4-e,. v P , , , /_e9 r /-4 / -. .. J! �p� z � � ran � Cam, c...--_ s 4 , /, i i i GP 7 e-,:4— (/' _e_Sb a 5 .to. Ai v .,.-1 ,46. / Requester: - ..r 4 . 7 ..4 ,_ 1177 l/ i� =::::- .S .1/ f/ ., 7/ °P 7.. /Is- -,rh/'1/41,'(_��r7/;4 -74.-, L J 4 Project: 1 77le , 1 ,) 1""e( Type of Inspection: A /t' /Ai6 Address: 3 /5 S.O. /1/A! / Date Called: Q 2 - 2. Special Instructions: Date Wanted: c0--2V—CL/ a.m. p.m. Requester: Phone No: ,0v& a // -3fo ? INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA "98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit (206)431 -3670 IE Corrections required prior to approval. Inspector: I- Date: El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Projec / Type of Inspectioon: r Addr s : ! � toCalle Special Tfistructions: Date Wante • —a. Requester: Phone No: • INSPECTIO N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit (206)431 -3670 COMMENTS: Approved per applicable codes. J f I Corrections required prior to approval. ❑ $47.00"INSPE 10 P' E REQUIRED. Prior to inspection, fee must re paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: CJ 64 -- c -- N. 1i 9J ° -- re-AP (?4 L- I Y c) 2-- A itfi H i2ets ILP o f ; s 37a, I) u)m # it 3 / Li viewitt' p / 4 ,iewl . Adr red 1 S S , ! WI a I ( Date Called: ,,, i :? Special Instructions: Date Wanted: a f '7/�( a:m p.m. Requester: t )414 Pho a No: � 0, aqa - ib3 Project � ( t Type o Inspection: , I'cp'l -.t// Adr red 1 S S , ! WI a I ( Date Called: ,,, i :? Special Instructions: Date Wanted: a f '7/�( a:m p.m. Requester: t )414 Pho a No: � 0, aqa - ib3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431. 3670 Approved per applicable codes. (Receipt No.: El Corrections required prior to approval. .u� .1 44.4 Date: - J ) _ 1 ? --- o 7.00 REINSPECTIO l FEE REQUIREDJPrior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: COMMENTS: /J /�/t t ` Type of Inspec � r N) ,(/t A ss E ffrt ctii r" Special Instructions: Date Wanted: wl '',h t--S. (Iv i ki 1 -Q - -Co ✓ 140 (0 , Pro' c /J /�/t t ` Type of Inspec � r N) ,(/t A ss E ffrt ctii Da t e l ia I d: Special Instructions: Date Wanted: /// �"'� r Requeste • Pho a No: 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMI 0 1 CITY OF TUKWILA BUILDING DIVISION, 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (20•) -3670 Approved per applicable codes. El Corrections required prior to approval. Date: to inspection, fee must be Ito schedule reinspection. Date: $47.00 REINSPECTION FEE REQUIRCb. Prior paid at 6300 Southcenter Blvd., Sui4100. Ca COMMENTS: r / a'i,1 s /ry Gcl4 /i! ,f-iw -A/ / 5 -/4 4 L, .y, ,-/ e f' 1/, 0 rt 5 P_iar 2 a V e h1 /.! v 5 ? i / -,v, s .-., -- L / ��/ 2t , i� . Special Instructions: Date Wanted: p[ / 2 all p.m. Requester C ` p° V Phone o: v 9v6 - 2-y/ 3/0 Projec : / ?° _I ire), i/ "e'C` Type of Inspection: of IVO / Al A Date 3 /'5 0) / AP/✓ -' / //A // Called: c, — / 2— U y Special Instructions: Date Wanted: p[ / 2 all p.m. Requester C ` p° V Phone o: v 9v6 - 2-y/ 3/0 3. .^ n 7-r-r. ;". ;,�.vr "flikpproved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 "JO g2-6 PERMI U (206)431 -3670 Corrections required prior to approval. Date: inspec,•r: `/ 47.00 REINSPECTIO FEE REQUIR . Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suit 100. Call to schedule reinspection. Receipt No.: Date: Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: FINALAPP.FRM Needs shift inspection Authorized Signature City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM ...Re.tain current inspection schedule Approved without correction notice Approved with correction notice issued Rev. 2/19/98 • 17- Steven M. Mullet, Mayor Thomas R Keefe, Fire Chief Permit No./ /1 1 (./ -?- ) Project Name g b Address 6 25 /21 )1 II Suite # Date T.F.D. Form F.P. 85 Headquarters Station: 444 Aldover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 October 27, 2003 Mr. Tim Schenk 1120 East 80 Street, Suite 211 Bloomington, MN 55420 City of Tukwila Department of Community Development Steve Lancaster, Director RE: Letter of Incomplete Application #1 Development Permit Application Number D03 -326 The Limited — 315 Southcenter Mall Dear Tim: This letter is to inform you that your application received at the City of Tukwila Permit Center on October 22, 2003, is determined to be incomplete. Before your application can continue the plan review process the following items need to be addressed: Public Works Department: Dave McPherson, at 206 431 -2448, if you have questions concerning the following: 1. Please provide a completed Non - Residential Sewer Use Certification (enclosed). Please address the above comments in an itemized format with applicable revised plans, specifications, and/or other documentation. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 433 -7165. Sincerely, Stefan . Spencer Permit Technician Enclosures File: Permit File No. D03 -326 Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206-431-3665 .... ki:..wy uS.i�. S......,.... -L hh..�...4�ati:w, a7: b1L::. u:: tra,: 1. :;C:�:t:;a.af.,5`daiM.ltµsci�i •.::uA:?.n.0 .,- -1 i.' •we:•.«iaW:t.+,s.' t�u;Ltaa3Yt::in:.N: • SHREMSHOCK ARCHITECTS, INC. 6130 S. Sunbury Rd Suite 100 614.545.4550 email: arch(Tshremshock.com To the Contractor: Columbus, OH. 43081 fax: 614.545.4555 http: / /www.shremshock.com (PLEASE BIND INTO CONTRACT DOCUMENTS) THE LIMITED SOUTHCENTER Store #688 633 SOUTHCENTER MALL SEATTLE, WA. 98188 ARCH PROJECT No.: 03341.R01 Gerald S. Shremshock, AIA Ohio Reg. No. 6968 CITY CF I U :v /iL FEB 2 0 2 This bulletin, issued after the execution of the contract, describes proposed revisions of the contract documents and requests from contractor the amount of change, if any, in contract sum to accomplish the work described. It is assumed no change in contract time will be necessary unless contractor submits written request for time extension, including justification, with his proposal for work described in this bulletin. Except, as otherwise described herein, or as shown on drawings issued with this, current contract documents apply to proposed work. This bulletin is not an order to do work. After receipt and review of the proposal requested, a change order will be issued to authorize execution of the work, or portion thereof, if the owner so directs. ►S ON'FORREVISION Submit proposals for the change described herein on Contractor's letterhead. List each item individually as listed below. DRAWINGS INCLUDED WITH THIS BULLETIN: A00.0, A00.1, A00.2, A01.1, A02.1, A02.2, A04.1, A05.1, A06.1, A07.1, A07.2, A08.1, A08.3, A08.4, A08.5, A08.6 DRAWING REVISION PROPOSALS: ANDLORD COMMENTS/DESIGNCHANGES nun iL A00.0 - COVER SHEET • Revised Space # in Key Plan, Usuage History and Title Information (Per Landlord Comments) • Added Revision information A00.1 — RESPONSIBILITY SCHEDULE • Lined out Rolling Grille and Sole Plate and added Entry Doors and hardware in storefront responsibility section (Per design change) A00.2 — FINISH AND DOOR SCHEDULES • Added door number 1, Pair of Entry doors, to schedule (Per design change) • Revised door #15 to "Not used" (Per design change) • Unlined hardware note "A" (Per design change) • Lined out hardware note's "C" & "D" (Per design change) i RECEIVED (:ITY OF TIIKWII A JAN 2 8 2004 PERMIT CENTER SHREMSHOCK ARCHITECTS, INC. 6130 S. Sunbury Rd Suite 100 614.545.4550 email: arch@shremshock.com Columbus, 01-1. 43081 fax: 614.545.4555 http: / /www.shremshock.com A01.1 — DEMOLITION PLAN • Revised note for space to be returned to future tenant (Per la ndlord comments) A02.1 — CONSTRUCTION FLOOR PLAN • Revised storefront entry from rolling grille to doors (Per design change) A04.1 — REFLECTED LIGHTING PLAN • Revised storefront entry from a rolling grille entry to doors (Per design change) • Revised ceiling heights at storefront to match change in bulkhead height (Per landlord comments and design change) A05.1 — FLOOR AND WALL FINISH PLAN • Revised storefront entry from a rolling grille to doors (Per design change) A06.1 — PRESENTATION & FIXTURE PLAN • Revised storefront entry from a rolling grille to doors (Per design change) Gerald S. Shremshock, AIA Ohio Reg. No. 6968 A07.1 — INTERIOR ELEVATIONS • Revised elevation "A" to reflect bulkhead and storefront ceiling height changes and MT -1 on interior wall at storefront (Per landlord comments and Design Changes) A07.2 — INTERIOR ELEVATIONS • Revised elevation "A" to reflect Bulkhead and Storefront Ceiling height changes and MT -1 on interior entry wall (Per landlord comments & Design changes) • Revised elevation "H" to reflect entry doors and storefront ceiling height changes (Per landlord comments and design changes) A08.1 - STOREFRONT ELEVATION • Revised storefront elevation to reflect entry doors and new bulkhead & Storefront heights (Per landlord comments & Design changes) A08.3 — STOREFRONT SECTIONS AND DETAILS • Revised sections "A" & "G" to reflect new bulkhead & storefront heights and adjusted all framing and attachments accordingly. (Per landlord comments and design changes) • Revised section "G" to show entry doors (Per design change) A08.4 — STOREFRONT DETAILS • Revised Detail "A" to show entry doors (Per design change) • Revised Detail "C" to reflect MT -1 Extending into entry (Per landlord comment) • Revised framing in detail "F" for entry doors (Per design change) A08,5 — STOREFRONT SECTIONS AND DETAILS • Revised sections "A" & "G" to reflect new Bulkhead and Storefront heights and adjusted all framing attachments accordingly (Per landlord comments and design changes) • Voided details "K ", "L ", and "M" (Per design change) Z 4- w re 2 0 u, co 'Li J I— WO u. co � = I— W Z Z0 W • W U � O N H W W , I O .. W U= O ff ' Z SHREMSHOCK ARCHITECTS, INC. 6130 S. Sunbury Rd Suite 100 614.545.4550 email: arch @shremshock.com Columbus, OH. 43081 fax: 614.545.4555 http : / /www.shremshack.com Gerald S. Shremshock, ALA Ohio Reg. No. 6968 A08.6 — STOREFRONT SECTIONS • Revised section "A" to reflect new bulkhead & storefront heights and adjusted all framing and attachments accordingly (Per landlord comments and design changes) END OF REVISIONS KMM LIMITED LIMITED STORE PLANNING, INC. d /b /a STORE DESIGN & CONSTRUCTION 3 LIMITED PARKWAY COLUMBUS, OHIO 43230 614- 415 -7000 PROPOSALS: BULLETIN: #1 DATE: 1/23/04 H B K PROJECT #03132 TO CONTRACTOR: (PLEASE BIND INTO CONTRACT DOCUMENTS) LIMITED SOUTHCENTER MALL SEATTLE, WA STORE #688 THIS BULLETIN, ISSUED AFTER THE EXECUTION OF THE CONTRACT, DESCRIBES PROPOSED REVISIONS OF THE CONTRACT DOCUMENTS AND REQUESTS FROM CONTRACTOR, THE AMOUNT OF CHANGE, IF ANY, IN CONTRACT SUM TO ACCOMPLISH THE WORK DESCRIBED. IT IS ASSUMED NO CHANGE IN CONTRACT TIME WILL BE NECESSARY UNLESS CONTRACTOR SUBMITS WRITTEN REQUEST FOR TIME EXTENSION, INCLUDING JUSTIFICATION, WITH HIS PROPOSAL FOR WORK DESCRIBED IN THIS BULLETIN. EXCEPT, AS OTHERWISE DESCRIBED HEREIN, OR SHOWN ON DRAWINGS ISSUED WITH THIS BULLETIN, CURRENT CONTRACT DOCUMENTS, APPLY TO PROPOSED WORK. THIS BULLETIN IS NOT AN ORDER TO DO WORK. AFTER RECEIPT AND REVIEW OF THE PROPOSAL REQUESTED, A CHANGE ORDER WILL BE ISSUED TO AUTHORIZE EXECUTION OF THE WORK OR PORTION THEREOF IF THE OWNER SO DIRECTS. SUBMIT PROPOSALS FOR THE CHANGE DESCRIBED HEREIN ON CONTRACTOR'S LETTERHEAD. LIST EACH ITEM INDIVIDUALLY AS LISTED BELOW. DRAWINGS INCLUDED WITH THIS BULLETIN: E02.1, E02.2, E02.3, E03.1, E05.1, F02.1, MO2.1, M04.1 DRAWINGS CHANGES: SHEET E02.1 A. DELETED CODED NOTE # 23 PER ARCHITECTURAL DESIGN CHANGE. uN.er b:llsr 'd.Jry; . <lia:t 't4g..11 ihsiJ:i SHEET E02.2 A. REVISED PLANS PER ARCHITECTURAL DESIGN CHANGES AT STOREFRONT B. DELETED ROLLING GRILLE PER DESIGN CHANGE. SHEET E02.3 A. REVISED BASEBOARD CIRCUITING PER DESIGN CHANGE. SHEET E03.1 A. REVISED PLANS PER ARCHITECTURAL DESIGN CHANGES AT STOREFRONT. B. REVISED CIRCUITING PER DESIGN CHANGE. SHEET E05.1 A. REVISED PANEL SCHEDULES, LOAD SUMMARY, WIRING SCHEDULE PER ARCHITECTURAL DESIGN CHANGE. SHEET F02.1 A. REVISED PLANS PER ARCHITECTURAL DESIGN CHANGES AT STOREFRONT. B. ADDED SPRINKLER HEADS PER DESIGN CHANGE. SHEET MO2.1 A. REVISED BACKGROUND PER ARCHITECTURAL DESIGN CHANGE. NO CHANGE TO THE WORK ON THIS PLAN. SHEET M04.1 A. REVISED PARTIAL PLAN TITLE. ........raw.ti.l:l�ty �J. a `si�.'ri.sJ.'.V✓':.:...r..t:.+r ...r..u.f:.v:.:.. .wt..�.... i c�tit'�s. :i!�.tti�'.fv.: Project Info Project Address Southoeatez Date 10/09/2003 633 Southosnter (fall For Buiidingi n ent Use RITl' nF root/ L l 0 C T 2 2 2003 PERMIT CENTER Seattle, Mk Applicant Name: H a n Consultants, Lta. Applicant Address: 172. Charring Cross Drive South Wasterviile, Ohio Applicant Phone: (614) ee2-1199 t} roJec ummary IP OP I y 2001 Washington State Nonresidential Energy Code Compliance Forms ,,o nlimmnmmmInt0ntnIntnttmtnnnntm 44 01, 44. rri 7 S * WAS l 5y S 1' .cfi 4r. i s i,Q h � o _ h rmtu � EXP I RES nrr 6 /1 tmt rntutrnnna U r-larctq^ f i that fhr, PIPr " "' 1%nrrfrllS arr? mot CITY OF TUKWI A APPROVED DEC - 3 2003 AS iJ i. Revised June 2002. KJM Project Info Project Address sontheenter ❑ Less than 60% of the fixtures are new, and installed lighting wattage is not being increased Date 10/09/2003 693 southcanter hall Retail For Building Department Use Seattle, 116. 5663.0 Applicant Name: x H K consultants, Ltd. Retail Applicant Address: 171 Charring Cross Drive South Westerville, Ohio Applicant Phone: (614) 862 -1199 8494.5 Alteration Exceptions (check appropriate box) • No changes are being made to the lighting ❑ Less than 60% of the fixtures are new, and installed lighting wattage is not being increased Location (floor /room no.) Occupancy Description Allowed Watts per ft -- Area in f Allowed x Area Retail Retail 1.50 5663.0 8494.5 Retail Retail - Merchandise Display 1.50 5663.0 8494.5 Hi - Recessed adjustable Doxnlight (excepted) 4 46.0 184.0 -- From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 16989.0 Location (floor /room no.) Fixture Description Number of Futures Watts/ Fixture Watts Proposed AS - Recessed fluorescent Downlight 65 32.0 2080.0 Al - Recessed fluorescent Downlight 3 32.0 96.0 Hi - Recessed adjustable Doxnlight (excepted) 4 46.0 184.0 RR- Recessed adjustable Downlight 2 37.0 74.0 HT - assessed adjustable incandescent Downlight 8 37.0 296.0 F4 - fluorescent Strip 1 32.0 32.0 TIC - fluorescent Strip 8 32.0 256.0 TN - fluorescent Strip 1 85.0 85.0 fo - Fluorescent Strip 1 112.0 112.0 fR - fluorescent Strip 4 32.0 128.0 H9 - Recessed Incandescent Dovnlight 66 20.0 1320.0 L5 - fluorescent strip 3 42.0 126.0 L6 - fluorescent Strip 10 51.0 510.0 L7 - fluorescent strip 3 76.0 228.0 LH - fluorescent Strips 5 42.0 210.0 Ni - Surface Mounted fluorescent Wraparound 4 32.0 128.0 T2 - Track Heads (214 x 5011- 10,700x) Track Length say 214 50.0 10700.0 TC - Track Head (excepted) TO - Track Head (excepted) Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 16565.0 ig ting ummary 2001 Washington State Nonresidential Energy Code Compliance Forms IC 1l1►rl • Revised June 2002 - KJM Project Description ❑ New Building ❑ Addition !1 Alteration ❑ Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive ® Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Maximum Allowed Lighting Wattage (Interior Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. Proposed Lighting Wattage (Inter-444st all futures. For exempt lighting, not exception and leave Watts/Fbature blank. Location Description Mowed Watts per ft or per If Area in ft (or If for perimeter) Allowed Watts x ft2 (or x If) Covered Parldng (standard paint) 0.2 W/ft Covered Parking (reflective paint) _ 0.3 W/ft Open Parking 0.2 W/ft Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts Outdoor Areas - 0.2 W/ft Bldg. (by facade) 0.25 W/ft Bldg. (by Imo) _ 7.5 W/if Location Fixture Description Number of Fixtures Watts/ Endure Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts Maxim Allowed Lighting Wattage (Exterior Not for building exterior, choose either the facade area or the perimeter method, but not both) Total Allowed Watts Use mtgr listed =mum input wattage. hor futures with Proposed Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. Use LPA` Use' LPA (W/sfl 1.5 Painting, welding, carpentry, machine shops 2.3 Police and fire stations Barber shops, beauty shops 2.0 Atria (atriums) 1.0 Hotel banquet/conference/exhibition hall 2.0 Assembly spaces ° , auditoriums, gymnasia ° , heaters 1.0 Laboratories 2.0 Group R -1 common areas 1.0 Aircraft repair hangars 1.5 Process plants 1.0 Cafeterias, fast food establishments' 1.5 Restaurants/bars' 1.0 Factories, workshops, handling 1.5 Locker and/or shower facilities 0.8 Gas stations, auto repair shops 1.5 Warehouses ", storage areas 0.5 Institutions 1.5 Aircraft storage hangars 0.4 Libraries 1.5 Retain retail banding 1.5 Nursing homes and hotetitlrtotel guest rooms 1.5 Parking garages See Section 1532 Wholesale stores (pallet rack shelving) 1.5 Mall concourses 1.4 Plans Submitted for Common Areas Only Schools buildings (Group E occupancy only), school classrooms, day care centers 1.35 Main floor building lobbies' (except mall concourses) 1.2 Laundries 1.3 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Office buildings, office/administrative areas in facilities of other use types (including but not limited to sch ols, hospitals, institutions, museums, banks, 12 ig ing ummary sac U 2001 Washington State Nonresidential Energy Code Compliance Forms Revised June 2002 - KJM Prescriptive Spaces Qualification Checklist Note: If occupancy type Is "Other" and fixture answer is creased, the number or figures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Occupancy: 0 Warehouses, storage areas or aircraft storage hangers ® other Lighting Fixtures: 0 Check here if at least 95% of fixtures in the space meet all four criteria: 1. Fbttures are fluorescent, ran - lensed, with only one or two lamps, and 2. Lamps are T-1, T 2, T-4, T-5, T-6, T-E 3. Lamps are 5-50 Watts, and 4. Ballasts are electronic ballasts 5. Exit lights < 5 watts/fixture 6. Screw -in compact fluorescent fixtures do not qualify TABLE 15 -1 Unit L Power Allowance (LPA Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases In which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified In the table. See Section 1512 for exempt areas. 2) The watts per square foot may be Increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be Increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Ught Power Allowance for assembly. 5) Watts per square foot of room may be Increased by two percent per foot of ceiling height above nine feet. 6) Includes pump area under canopy. 7) In cases in which a lighting plan Is submitted for only a portion of a floor, a Unit Lighting Power Allowance of 1.35 may be used for usable office floor area and 0.80 watts per square foot shall be used for the common areas, which may include elevator space, lobby area and rest rooms. Common areas, as herein defined do not include mall concourses. 8) For the fire engine room, the Unit Ughting Power Allowance Is 1.0 watts per square foot. 9) For indoor sport tournament courts with adjacent spectator seating, the Unit Ughting Power Allowance for the court area is 2.6 watts per square foot. 10) Display window illumination installed within 2 feet of the window, lighting for free- standing display where the lighting moves with the display, and building showcase illumination where the lighting is enclosed within the showcase are exempt. An additional 1.5 w /tt of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually Installed. 11) Provided that a floor plan, indicating rack location and height, Is submitted, the square footage for a warehouse may be defined, for computing the Interior Unit Ughting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Z H Z re al 0 W = H N W W < =a l.. W Z = E- 0 Z W O • N O 1-- W W IU O W Z U N 0 Z 1g ing 'ower A owance A •bus men s 2001 Washington State Nonresidential Energy Code Compliance Forms Ad'tusted Li i t ting Power Allowances (Interior Revised June 2002 - KJM 'Project Address jaouthoenter j oate 10/09/2003 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15-1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment Is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft Carry the Adjusted LPA to the corresponding "Allowed Watts per ft location on LTG -SUM. j Location (floor /room no.) Occupancy Description Allowed Watts per ft " Ceiling Height for this room Ceiling Height limit for this exception" Adjusted LPA Watts per ft From Table 15-1 based on exceptions listed in footnotes Ig ing •ermi ' ans ec is - 2001 Washington State Nonresidential Energy Code Compliance Forma Revised June 2002 - KJM Project Address soutnoeoter 'Date 10/09/2003 The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the 1994 Washington State Nonresidential Energy Code. Applicability I (yes, no, n.a. ) Code Section Com 'information 1 Required I Loation I on Plans Building Department Notes LIGHTING C ONTROLS (Section 1513 Yes 1513.1 Local controUaccess Schedule with type, Indicate locations n. a. 1513.2 Area controls Maximum limit per switch - n. a. 1513.3 Daylght zone control Schedule with type and features, indicate locations n. a. vertical glazing Indicate vertical glazing on plans n. a. overhead glazing Indicate overhead glazing on plans n. a. 1513.4 Display /exhib/special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, Indicate location p. a. (a) timer wlbackup Indicate location - n. a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations n • a. 1513.6.2 (b) auto. switches Schedule with type and features (back-up, override capability); Indicate size of zone on plans _ 4 1513.7 Commissioning Indicate requirements for lighting controls commissioning yes Lighting Sum. Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n • a• I (Elea motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I If "no" is circled for any question, provide explanation: , 19 ting 'errnit ' ans ec 1st 2001 Washington State Nonresidential Energy Code Compliance Forms Revised June 2002 - KJM Lighting - General Requirements 1513 Lighting Controls. Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a twenty ampere circuit loaded to not more than eighty percent. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than five percent of footprint for footprints over 100,000 square feet. 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight -or occupant - sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition, and Specialty Lighting Controls: All display, exhibition, or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -0ff Controls, Exterior: Exterior lighting not intended for 24 -hour continuous use shall be automatically switched by timer, photocell, or a combination of timer and photocell. Automatic time switches must also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. 1513.6 Automatic Shut-Off Controls, Interior: Office buildings greater than 5,000 sq. ft. and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Automatic controls may be an occupancy sensor, lime switch, or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated, or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day dock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back-up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a) is readily accessible; b) is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; and c) is manually operated; d) allows the lighting to remain on for no more than two hours when an over -ride is initiated; and e) controls an area not exceeding 5,000 square feet or 5 percent of footprint for footprints over 100,000 square feet, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure ttiat control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 • .5 / 1 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 2. 4- Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 1 3 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Water closet, tank or valve, 1.6 GPF 6 3 2_ 16 Water closet, tank or valve, >1.6 GPF 8 4 • Non- Residential Sewer Use Certification (To be completed for all new sewer connections, reconnections or change of use of existing connections. This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect.) Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for (Please print or type) Property Tax ID # Owner's Name V4ESIPIELD 000.900A1101.4 • (Last, First, Middle Initial) Party to be Billed (if different from owner) („I MMEU 02006%3 Subdivision Name Lot # Party's Mailing Address: Subdiv. # Block # el o CA S S I N FOCLMA tON S'STErVS Po Gat '6 72602- Go wm 0 1-4 43218.15302 Building Name (if applicable) THE Uiv iT O e. 5QJTI4C. YIlE. Property Street Address 315 S )V134,Ce EQ MALI -. S'01 re100 City, State, ZIP T■I<WIIA I A. 9$ISB Owner's Phone Number ( Owner's Mailing Address (if different from above) I lb W a 1 1t I QE ILvO ►2 Ft.o iz_ Los Arr rG GLes I CA aooZ.S• A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Total No. of Fixture Units _ 20 1 ' d Rev. 1/03) Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE 1rz RCE White — King County 2 King County Department of Natural Resources and Parks new sewer customers. The charge is collected semi - annually. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at (206) 684 -1740. City or Sewer District Date of Connection Side Sewer Permit # P7 3 -S or Property Contact Phone # ( 6 y ) 415'. 1998 Demolition of pre- existing building? ❑ Yes liKo Type of building demolished Sewer disconnect date B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) _ 187 C. Total Residential Customer Equivalents: (add A & B) A B Z RCE RCE INCOMPLETE I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Signature of Owner Representative Print Name of Owner/ Representative 'Ti tV1 S C NEN I&. 11jl2(03 Date Yellow — Local ,� Sewer p A � g Pink — Sewer Customer ' oe a� ency iW:14 raf-!.. "'L'Mha�.� >�Ifyl .11?1;'L'fftts' .vYMktlhYi T, k" t' 14'.k ')nY�tl r:`+�w.*.wa,�. ;�v •45211,rmri Revision' No. Date Received i Staff 1 Date Initials i Issued Staff Initials ''Staff Initials 1 / -z8-05 i &leg I - ,2 ' / . - S Summary of Revision: /i�e.R. ,Pra - T/ _ow r ,fr,./a T�rn E ,,,, • , Received By :, � 2_ Z4- Revision No. ' . Date Received Staff Initials Date I Issued Staff Initials 1 Summary of Revision: Received By: PROJECT NAME: 77/./6 4//l /77 b PERMIT NO :, — 324 Site Site Address: Revision No. Summary of Revision: Revision No. Summary of Revision: Revision No. Summary of Revision: Date Received Date Received Date Received REVISION LOG Staff Initials Staff Initials Staff Initials Received By: Origin,., Issue Date: / y Received By: Received By: Date .. Issued Date Issued Date Issued (please print) (please print) (please print) (please print) (please print) Staff Initials Staff Initials Staff Initials ACTIVITY NUMBER: D03 -326 PROJECT NAME: THE LIMITED SITE ADDRESS: 315 SOUTHCENTER MALL DATE: 01 -28 -04 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 after /fie permit is issued DEPART �� MENNTS: Buildin "i5vi i� on G LD / j 2� rO ( Fire Prevention N Public Works 12'lik Structural ❑ APPROVALS O CORRECTIONS: i lt REVIEWER'S INITIALS: Documents /routing slip,doc 2-28-02 DERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 'EMIT COORD COPY Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 01 -29 -04 Complete [V Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R�TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 02 -26 -04 Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: r�? ..*11:41..4.41:464 .. -mac 1i lEs3i6d " itx6i..::tia«Ert�i li:x;,rva"tt;. �<..t x".a,.i 5,wn 4.141 ' zAL L.4.. ACTIVITY NUMBER: D03 -326 PROJECT NAME: THE LIMITED SITE ADDRESS: 315 SOUTHCENTER MALL Original Plan Submittal DATE: 11 -17 -03 X Response to Incomplete Letter # I Response to Correction Letter # Revision #_after /before permit is issued DEPARTMENTS: f 2 -z -c BuildirMvis fd n Public Works , ^ A *1/1-10--0 7, PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention ❑ Planning Division ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -18 -03 Complete Nr Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions [� Not Approved (attach comments ❑ pp ❑ pp Pp ( ) Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip,doc 2.28.02 PERMIT COORD COPY Not Applicable ❑ DUE DATE: 12 -16 -03 DATE: 'x,,441 4171 i:.S:uu.iazuu�.: :+ cva: r.. •:.,x:.t,.;�n.-.w.+..:+�a++.ay. ray .. +.':.'etJi:»c z = z re W ..t U 00 w J = H W g Q = 1— w Z = 1- 1— O z w w 0 I-- w ill O .. w U= O z ACTIVITY NUMBER: D03 -326 PROJECT NAME: THE LIMITED SITE ADDRESS: 315 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after /before permit is issued DEPARTMENTS: Building Division Documents /routing slip.doc 2 -28.02 PERMIT COORD CUPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: U Fire p revention E Public J(,Vgfks l dAiyi ID � 1� c7 Structural ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10 -23 -03 Complete ❑ Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: /" 7. ' °.2) LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW Staff Initials: a,fr S TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY DATE: 10 -22 -03 Not Applicable ❑ DUE DATE: 11 -20 -03 DATE: CI (- fl tL - ) o - v 1 Planning Division Permit Coordinator ir City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /— 25c Plan Check/Permit Number: � - ID Response to Incomplete Letter # Response to Correction Letter # Revision # / after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: /e t , t �'t� t/ Project Address: 3/5— .$o )Td e['U}fc.=2 M 4 /? t w Contact Person: Phone Number: 296 - 2q, - - - S/03 Summary of Revision: S I c.#v% (4't? '" lure -lL � f�- �4�C�s 4 kel ' JANE 2 v Pp 2004 /reeiv A 06.1 ©7, 4-o717 A_ . I 14 (5' 4 , Sheet Number(s): if . 0 A.00 • 1 60.2 461. ( lk. , 1 4 Ll, I ACT ( "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by:S Entered in Permits Plus on -2-6"Z? 08/06/03 u:u F INIMMI■MININIP REVISION SUBMITTAL i Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: I I — 1' -Cr3 ® Response to Incomplete Letter #_1 ❑ Response to Correction Letter # ❑ Revision # after/before Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: THE LIMITED Project Address: 315 SOUTHCENTER MALL Contact Person Tim Schenk Phone Number 1-800 • S14 • OSZf Summary of Revision: Sheet Number(s): I A- • City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Received at the City of Tukwila Permit Center by: gr Entered in Sierra on l (J 1 ( Plan Check/Permit Number: D03 -326 /voN- 2E5 D EN L. SEWER. VSE C RT( ICAn . "Cloud" or highlight all areas of revision including date of revision ck) ECEIVED CITY OF TUKWILA NOV 1 7 2Q03 T CENTER 1 0/27/03 F625. 052.000 (8/97) REGISTERED AS 'PROVIDED BY AS CONS •CQ T GENERAL '+ii ,.•• ,� �l't , � G , � T� ` ii( ��` ' ? ; f� X P . r, • :.` {, i �� O SH RADI!4„ • i'"`� OB, ;o1 EFFFCTIVE`''DATE ' O1 /O3'1993 SHRADER- &: ;MARTINEZ CONST I,NC; 20,30-W. 89A_ STE. B2 SEDONA AZ 86336 F625.1)52 -000 (8/97) Detach And Display Certificate REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL i REGIST. # EXP. DATE CCO1 SHRADMC070BC 01/10/2005 EFFECTIVE DATE 01/03/1993 SHRADER & CONST INC 2030 W HWY 89A STE B2 SEDONA AZ 86336 Signature Issued by DEPARTMENT OF LABOR AND INDUSTRY m r z o Please R nd ► And $kn sty Identifi•; io 1 Card BeforC Placing In Billfold • ANY DISCREPANCIES BETWEEN THE EXISTING CONDITIONS, DOCUMENTS, AND THE ACTUAL FIELD CONDITIONS SHALL BE BROUGWT TO THE ATTENTION OF THE LSDSC PROJECT MANAGER BEFORE PROCEEDING WIN ANY WORK. 2. THE CONTRACTOR SHALL REVIEW ALL DOCUMENTS AND VERIFY ALL DIMENSIONS AND FIELD CONDITIONS AND SHALL CONFIRM TWAT WORK IS BUILDABLE AS SHOWN. ANY CONFLICTS OR OMISSIONS, ETC., SHALL BE IMMEDIATELY REPORTED TO THE LSD4C PROJECT MANAGER FOR CLARIFICATION PRIOR TO THE PERFORMANCE OF ANY WORK IN QUESTION, 3. WHEN CONTRACTOR ACCEPTS DELIVERY OF ALL ITEMS NOTED ON PLANS WHETNERR IN CONTRACT OR NOT IN CONTRACT, WE SHALL BE RESPONSIBLE FOR LOSS AND /OR DAMAGE TO THESE ITEMS. 4. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE DURATION OF TWE WORK ALL EXITS, EXIT LIGHTING, FIRE PROTECTION DEVICES AND ALARMS IN CONFORMANCE WITN ALL APPLICABLE CODES AND ORDINANCES. 5. DURING ALL PHASES OF WORK, DO NOT DISTURB THE DELIVERIES AND FUNCTIONS OF ADJACENT AND NEIGHBORING TENANTS. 6. 'TYR.' MEANS THAT THE CONDITION IS REPRESENTATIVE FOR SIMILAR CONDITIONS TNROUG,I.IOUT, UNLESS OTHERWISE NOTED, DETAILS ARE KEYED AND NOTED 'TYP.' ONLY ONCE WHEN THEY FIRST OCCUR. 7. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DRAWINGS. B. ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER OTHER DRAWINGS FOR LAYOUT DIMENSIONS AND NUMBER OF ITEMS PROVIDED. UPON DISCOVERY OF DISCREPANCIES BETWEEN ARCHITECTURAL DRAWINGS AND ENGINEERING DRAWINGS, OWNER'S PROJECT MANAGER SHALL BE NOTIFIED AT ONCE. 9. DIMENSIONS SI-IOWN ON PLANS ARE TO FACE OF GYPSUM BOARD, CONCRETE COLUMNS OR GRID LINES AND FACE OF EXTERIOR MASONRY UNLESS OTHERWISE NOTED OR DETAILED. 10 CONTRACTOR SHALL, IN THE WORK OF ALL TRADES, PERFORM ANY AND ALL CUTTING, PATCHING RESTORING, REPAIRING AND THE LIKE NECESSARY TO COMPLETE TWE WORK AND RESTORE ANY DAMAGED SURFACES RESULTING FROM T14E WORK TO THEIR ORIGINAL CONDITION. ALL ROOF PATCHING SHALL RETURN AREA TO 'LIKE NEW" CONDITION. PRIOR TO PATCHING, G.C. TO VERIFY ANY ROOF WARRANTIES WITN LANDLORD. 11. EACH CONTRACTOR SHALL LEAVE THE SITE IN A NEAT, CLEAN AND ORDERLY CONDITION UPON THE COMPLETION OF 1415 WORK ON A DAILY BASIS. ALL WASTE, RU86IS14 AND EXCESS MATERIALS SHALL BE REMOVED FROM THE SITE PROMPTLY. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL TRASH, INCLUDING OWNER- FURNISINED ITEMS AND TRASH GENERATED BY OWNER'S CONTRACTORS FOR THE DURATION OF THE PROJECT. 12 . CONTRACTOR SNALI. PROVIDE TWO FIRE EXTINGUISHERS (ONE EACH IN SALES AND NON - SALES) OR AS REQUIRED BY FIRE MARSHALL. VERIFY EXACT LOCATIONS WITN PROJECT MANAGER PRIOR TO INSTALLATION. EXTINGUISHERS TO WAVE A RATING OF NOT LESS THAN 2 -A CR 2- A/108C WITHIN 75' TRAVEL DISTANCE TO ALL PORTIONS OF TWE BUILDING DURING CONSTRUCTION. 13. A 44° CLEAR AISLE SHALL BE MAINTAINED THROUGH ROOMS TO EXIT DOORS AT ALL TIMES. 14. NO FOOD, ALCOHOL OR SMOKING IS TO BE STORED, SERVED OR CONSUMED ON TWE PREMISES. 15. ALL SECURITY DOOR AREAS TO BE PROVIDED WITN A KEY LOCKING DEVICE SO AS TO ENABLE DOOR TO BE LOCKED IN THE OPEN POSITION AND REMAIN UNLOCKED DURING BUSINESS HOURS (WITH THE EXCEPTION OF THE REAR SERVICE DOOR). 16. ONLY PANIC HARDWARE APPROVED AND LISTED BY TWE STATE FIRE MARSHALL SHALL BE INSTALLED. 17. EXIT DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING 50 OR MORE PERSONS. 18. DOORS OPENING INTO ONE -HOUR FIRE - RESISTIVE CORRIDOR SHALL BE PROTECTED •ITW A CLOSURE AND A SMOKE OR DRAFT STOP FIRE ASSEMBLY HAVING A MIN. 20 MINUTE RATING. 19. EXIT SIGNS SHALL BE ELECTRICALLY ILLUMINATED AND THE TWO LAMPS SHALL BE ENERGIZED FROM SEPARATE CIRCUITS. ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES WIRING SYSTEM. IN THE EVENT OF FAILURE OF THIS SYSTEM, ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY BACKUP SYSTEM. EMERGENCY LIGHTING SHALL GIVE A VALUE OF MINIMUM ONE FOOTCANDLE AT FLOOR LEVEL, UNIFORM THROUGHOUT EGRESS PATH. 20. FIRE DAMPERS SI4ALL BE PROVIDED BY MECHANICAL SUBCONTRACTOR WHERE DUCTS PENETRATE FIRE -RATED WALLS OR CEILINGS. REFER TO MECHANICAL DRAWINGS. 21. EVERY EXIT DOOR SMALL BE OPERABLE FROM TWE INSIDE WITHOUT THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE, OR EFFORT. 22. ANY MODIFICATIONS TO EXISTING SPRINKLER/ALARM SYSTEM AND EXTERIOR 51GNAGE WILL BE UNDER SEPARATE COVER(5) AND PERMIT(5). GENERAL NOTES 1. THE GENERAL CONTRACTOR Si4ALL ARRANGE FOR ALL 1 1 , 45PL5GT+0 415 AND FURNISI4 TWE 5TOim r•,ANAC;ER id TU TWE CERTIFICATE OF OCC:JF'ANCY ALSO, PROVIDE A LIST OF R M1 S, ADDRESSES, ND TELEPs4ONE NLP 13ER5 FOR A:..L/! U mourn) N O�R5, INCuJDec Au . VAR PROIr1DED _ 13(.7n 13(.7n . a E 5 "r0 BE ' S/) !t SEPARATE PICTURE FRArtS (b -a/7' x n') ON REAR OF PI/WAGERS OFFICE DOOR AT FAGF eiparr AND ONE C01''Y To OiNER'S PROJECT . 2. T«E GBERAi. CON'TRAC*'OR SHALL Also FUR ,4+ COPIES OF sUo 1111'15 TO Tl~E : v'ED SERVia CORPORA _ °lOOR "c .''ORE OPENING G.C_ S RESPONSOLE '"C ARRANGE FOR A ciER 1MDIEPEI 7Br BA 1. M4CDNG CONRAcvst BA►LA CE «• VAC 5rS'EM REFERENCE 'AIR AND PROCEDURES 04 mEOHANKAL MA/TANGS COCRACTOR SMALL ODE THE 4.ANCLORD AND G1alift"5 t'1ANAGER porno A CtOP'r OF 71f ISALAME WORT IF RED Br wDLORD /WE G_C..40441E SECURE HE NECESSARY AF'v•0Ve4, aF wows ER srgivr! Foal LANDLORDS F G.c 94A TURN AVER ALk KEYS TO STORE 1IANACE R CLEARLY wMSa% EACH +Ter FOR CIENTIFICATiat • G.C. SHALL MOM A PROFE95 CLEANING G SERVICE FOR 'NE STS AT TIE TIM CF CCMPLIT04. STORE SMALL BE CLEANED AGAIN AFTER minomposiNG or TIE STYE, AS IREOUIRED TO RETURN TO A .OUST-FREE. G01DIT1 N MOOR TO Gr@Ll& 7 G C. SWN6L BRAN OrENATKEM CIF ALL. re:110441ICAL. STSTE'B► TO Sim I"t swgzik 1 G`C, sou. INGRATE. ARiemeL E, AND 1rb7AfuL EB'911MME. 12484151 516PPUED MIMS I WORPINARE AlelrVlNG 47i1 PIEMNAMMIE IMO( O 46 G e impaeina TO PROVCE (►) 3C YARD TRAIN 4ORITAN R FOR 441.E 10714%. IAiIOE PACKS i P' 7ERWALS P'RM'M TO S'ICAE 4'.PM& aLK'P'STR TO SE AIMS Ka CAE (t) AS- JOHN.? SET ¢ ONMP4111615 !WILL WON Si PUNS TIME KI AE*. TURNOVER REOIIEMENTS PLAN DETAIL REFERENCE SWEET NUMBER PLAN SECTION REFERENCE SWEET NUMBER SECTION DETAIL REFERENCE SWEET NUMBER ELEVATION REFERENCE SWEET NUMBER CABINET/FIXTURE TYPE BLDG SECTION REFERENCE --• xx /Ax ELEVATION WEIGHT TARGET-. X' -Y" A.F.F. LOCATION IN SPACE -•'P LOCATION LAYOUT ORIGIN - -,'LAYOUT 4r POINT WALL TYPE DOOR NUMBER CODED NOTE REVISION SYMBOL REVISION CLOUD ROOM NUMBER WALL FINISH CALL -OUT -• BASE FINISH CALL -OUT - CABINET FINISH CALL - OUT ---• TRIM FINISH CALL - OUT- --• FLOOR FINISH CALL -OUT -• MOTE Pent CEILING 14EIG14T • 0' -0" CEILING FINISH • FINISH ADDITIONAL NOTES • FINISH CALL -OUT• FINISH ADDITIONAL NOTES-. tart NOTE ROOM • number G T F wal l base cabinet trim fl oor SYMBOLS LEGEND ABV A.F.F. ALUM BD BLKG EV14 CALC.S CLG CAL CONC CONSTR N C .T.F. C/W EA ELEV ELV EQ EXIST EXT ABOVE ABOVE FINISH FLOOR ALUMINUM BOARD BLOCKING BACKWRAP CALCULATIONS CENTERLINE CEILING COLUMN CONCRETE CONSTRUCTION CONTINUOUS CUT TO FIT CASWWRAP EACH ELEVATION ELEVATOR EQUAL EXISTING EXTERIOR F.G.D. FINISH CABINET DIMENSION FD FLOOR DRAIN F.D. FIELD DETERMINED FIN FINISH FL FLOOR FLG FLOORING FLUOR FLUORESCENT FRT FIRE RETARDANT TREATED F.O. FINISHED OPENING F.R. FITTING ROOM G.G. GENERAL CONTRACTOR GYP (BD) GYPSUM (BOARD) N.G. HANDICAPPED N.D.F. HIGH DENSITY FIBERBOARD MGT HEIGHT 1.IORIZ HORIZONTAL NR HOUR INCAND INCANDESCENT INT INTERIOR LSD$C LIMITED STORE DESIGN CONSTRUCTION LAV LAVATORY L.L. LEASE LINE MAX MAXIMUM M.D.F. MEDIUM DENSITY FIBERBOARD MECH MECHANICAL MFG MANUFACTURER MISC MISCELLANEOUS MIN MINIMUM MTL METAL N.P. NEUTRAL PIER N.T.S. NOT TO SCALE O.C. ON CENTER OPNG OPENING PL PLEX PLYWD PREFIN P.M. R QP (REF) R.O. SECT SWT SIM SQ STL STRUCT TEMP THRU TYP U.N.O. V.G. VERT V.I.F. W/ WD W/O PLATE PLEXIGLAS. PLYWOOD PREFINISHED PROJECT MANAGER RADIUS REQUIRED REFERENCE ROUGH OPENING SECTION SHEET SIMILAR SQUARE STEEL STRUCTURE TEMPERATURE THROUGH TYPICAL UNLESS NOTED OTHERWISE VOLUME CONTROL VERTICAL VERIFY IN FIELD WITH WOOD WITWOU T ABBREVIATIONS SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 VICINITY MAP KEY PLAN FRONT APPROACH PUSH SIDE FRONT APPROACH PULL SIDE ELEVATOR: OFF - CENTERED DOOR 46" MIN pi4" M 610 'I 1220 '1 610 CLEAR WIDTH OF AN ACCESSIBLE ROUTE GENERAL ACCESSIBILITY CONDITIONS ARCHITECTURAL ADO PROJECT INFORMATION A00.0 COVER SWEET A00.1 RESPONSIBILITY SCHEDULE A002 FINISH AND DOOR SCHEDULES A00.3 NOT USED A01 TEMPORARY WORK A01.i DEMOLITION PLAN A01.2 DEMOLITION PLAN A01.3 NOT USED A01.4 NOT USED A01.5 NOT USED A01.6 NOT USED A01.7 NOT USED SEPARATE PERMIT AND APPROVAL A02 CONSTRUCTION REQUIRED A02.I CONSTRUCTION FLOOR PLAN A022 CONSTRUCTION FLOOR PLAN A03 REFLECTED CEILING A03.1 NOT USED A032 NOT USED A04 REFLECTED LIGHTING A04.1 REFLECTED LIGHTING PLAN A042 REFLECTED LIGHTING PLAN A05 FLOOR • 1441 FINISH A05.1 FLOOR * WALL FINISH PLAN A05.2 FLOOR t WALL FINISH PLAN A06 PRESENTATION 4 FIXTURE PACKAGE A06.1 PRESENTATION t FIXTURE PLAN A042 PRESENTATION * FIXTURE PLAN A07 INTERIOR ELEVATIONS A07.1 INTERIOR ELEVATIONS A072 INTERIOR ELEVATIONS A06 STOREFRONT GONSTRUCTIC7NJ A06.I STOREFRONT ELEVATION A082 STANDARD STOREFRONT DETAILS A06.3 STOREFRONT SECTIONS t DETAILS A06.4 STOREFRONT DETAILS A06.5 STOREFRONT SECTIONS t DETAILS A06.4 STOREFRONT SECTIONS A09 VERTICAL_ORGULATION A09.1 NOT USED MO CABINET ASSEI 4 MILL PACKAGE A10.1 NICHE LEDGE DISPLAY DETAILS A102 FLOATING DISPLAY WALL DETAILS A103 AA/AW t BA/HW CABINET DETAILS A10.4 NOT USED A10.5 BAC:KWRAP FOCAL DETAILS AI0.4 CABINET AND CONSTRUCTION DETAILS ,Al ll1W;101/ApICA5HirigAEA.5giroz All.1 4 TERM CA5I*RAP ASSEMBLY A112 BACK RAP ASSEMBLIES A113 NOT USED A11.4 NOT USED A11.5 4 T5 1 WAD CASI#NRAP A66HUS Al2 CONSTRUCTION DETA Al2.I PARTITKIN DETAILS Al2.2 FLOOR TRANSITION DETAILS Al2.3 CEILING AND LIGHTING DETAILS Al2.4 DOOR /JAM'B DETAILS Al2.5 COLUMN AND BASE DETAILS A13.1 WC PRIVATE TOILET / JAN CLOSET A132 STANDARD FITTING RDO1 DETAILS A133 HANDICAP FITTING ROOM DETAILS A13.4 MIRROR DETAILS Ai4 PRESENTATION PACKAGE A.EMLY A14.1 STOCKROa'1 SHELVING DETAILS A142 PRESENTATION FIXTURE DETAILS A14.3 PRESENTATION FIXTURE DETAILS A14.4 ICIT USED AS 5PEOPCATKI0 A15.1 SPECWICATIONS A52 SPECIFICATIONS AS .3 SPECIFICATIONS 'KO 3 •*-- - c , =�E CF ti CF ►. - : - fir Ml . r`. MEP STANDARDS LAO ENGINEERING SPECIFICATIONS E00.0 ENGINEERING SPECIFICATIONS ELECTRICAL 101 ELECTRICAL SPECIFICATIONS E01.1 ELECTRICAL SPECIFICATIONS £m E1 ECTRICAL POWER E02.1 ELECTRICAL POWER PLAN NOTES E02.2 ELECTRICAL POWER PLAN E02.3 ELECTRICAL POWER PLAN ELECTRICAL ,LIGHTING E03.1 ELECTRICAL LIGHTING PLAN AND NOTES E03.2 ELECTRICAL LIGHTING PLAN E03.3 ELECTRICAL LIGHTING SCHEDULE 1104 ELECTRICAL, DETAILS £04.1 ELECTRICAL DETAILS E04.2 ELECTRICAL DETAILS E05 ELECTRICAL S%WEDULES 1105.1 ELECTRICAL PANELS AND RISER DIAGRAM FIRE PROTECTION F02 SPRINKLER F02.1 SPRINKLER PLAN 4 SPECS F022 SPRINKLER PLAN MECHANICAL / M01 MECT4NICAL SPECACATIONS MOI.1 MEC1 A'EC.IFICATIONS r_Irsj 1 MO2.1 M ECIaAN A� MO22 MECNe111CAL Z I_ PIEc44m ICAL DETAIL!► M03.1 MECHANICAL LOAD 136LGS AND DETAILS M03.2 '1ECHANICAL DETAILS MO4.1 ME CH UNIT SUPPORT PLAIA PLUMBING EQummaraLlerafrAnglis Poll PLUMBING SPECIFICATIONS P02 PLUMBING P02.1 PLUMBING PLAN P03.1 PLUMBING ISOMETRICS 4 DETAILS TEMPERATURE CONTROL AND HVAC WIRING DIAGRAM TCO TEMPERATURES, TC0.1 TEMPERATURE CONTROL WIRING DIAGRAM SEPARATE PERMIT tG WIRED FOR: ECHANICAL CTRICAL LUMBING AS PIPING CITY OF TUKYVILA BUILDING DIVISION FILE COPY I understand that the Plan Check approvals are subject to errors and om and appravai ptats does not altL ior{ze the vazi aaon of ar*y adopted code or ord•rance Reoetpt of con - tracWs copy of aptro•ed pans aocnrlwledged_ 0 410“1111119 1 1 1 1(4,1L nom Desumics - 9rwnra no s _ i i ri1 N a~ * Sr ar l( sair . um, TWO S4uE ,;i1E in*** re11 NNo?T *AD11v era uSE am r orsrt rwr emojtcr spNE art ar • Lamp rw[ wrest or runt Oqu_M -CS ame irr'EClr'"2.rMPr6. mow O[l'AOWJC71011 rr"�LN[Cirr Qs ismOooLO MOW ES Pecrowrict ala COMMA' le LPN/ jilLESS LIPOLSAT MAO nu eirNs. Or uso1L Sr'ONE ouseerrrC. rr1C. OA" VOX GIMP on IVOISTIo,tnno X'1.SL1C - 1, IE'SE tOlooloGS a SPEC1P1C*Pai MI "we PRIM MI'''► E .SOC we Soma rMr OE "SoUr•i1 .1% an" rlrrPlNE, Ow 'm10 oPo a ' O1 r JEC EKE+* !* 111N atinunor nIr1M ISOC Tr0 E*epqNIC110% Orr rhoIrSIE COmminGS IMIa SPKIFICJInelle SWILL IN MME V/M1401$ nig A r1rr VICIO rw0r OF Poi L UC «u oMllf.1N1rLS Or WV 311111 1• S 111rA 9'iarrai ele OUST E rAETMrtE>t 1 C l3EC UPON COURnal or TWO 0.1111 1 MSC. wallaSS 01411111103E CEO Or rot 1SOC. COP""OiPT N INCE.. iota OMENKS w S*'EdsrCAN1A1S Mi ci.P.OSPInin +1Nrr1 .mitt - a COPPOOor IMOIE -'Or. NS r0 `050014ECTWNML Mier Jim* s - 62 Or not 111e.. S.C. r5 mitien a[ Mt. "VW rotor. a Mvgruweit awn t0►•revr► M'UOo11Ci"NOw err Of ,. I ANNE ORIPOUttime oriCIiMEE3. Wogs. kNNrMrtoseN4 not ONirlrrr�4. oprogritir gunk rrNC cisimpows sr sllums, M t>l rvirS a 1Mr11 OE9iMr. ~t Srwr AlOOrteMON4 r*Nr.11NIGOr►,NEs 4611 or >A ONONsa SIKORICAMOIS .n NEW •s CE1511 a C>aMPOMC110111L mow sl elot_ MVOR DRAG INDEX PROJECT SCOPE: THIS PROJECT IS THE DOWNSIZE/FULL REMODEL OF THE EXISTING "THE LIMITED" STORE. WORK IS TO INCLUDE, BUT NOT BE LIMITED TO, THE PARTIAL REMODEL OF EXISTING FLOORING, WALL CONSTRUCTION, LIGHTING AND CEILINGS. A PORTION OF THE STORE IS BEING RETURNED TO THE LANDLORD. NOTE: USAGE HISTORY: THE LIMITED PROPOSED Une THE LIMITED SPACE NUMBER(S)= 100 IS TO BE USED EXCLUSIVELY FOR RETAIL SALES P031-,Olp SCOPE OF WORK STORE TYPE: THE LIMITED RETAIL APPAREL SALES LOCATION: SOUTHCENTER LEVEL: I OF 1 APPLICABLE CODES: WASHINGTON STATE BUILDING CODE - 1997 WASHINGTON STATE PLUMBING CODE - 2000 WASHINGTON STATE MECHANICAL CODE - 1997 WASHINGTON STATE ELECTRICAL CODE BUILDING OCCUPANCY USE GROUP: M - MERCANTILE CONSTRUCTION CLASSIFICATION: TYPE: 2N FIRE PROTECTIOIN DEMISING NALL 1 HOUR SALES/NON-SALES WALL.. 0 CEILING 0 COLUMNS 0 SPRIIIACLERED: FULLY SPRINIU.,ERED OCCUPANT LOAD: (4,469/30) + (1,21/30) = 153 REQUIRED EXITS: NUMBER: 2 MAXIMUM TRAVEL DISTANCE: 200' RESTROOM REQUIREMENTS: WATER CLOSET 1 REQUIRED FOR MALE 1 REQUIRED FOR FEMALE LAVATORIES: I REQUIRED FOR MALE 1 RB2JIRED FOR FEMALE URINALS WA DRINKING FOUNTAINS DRINKING FOUNTAN PROVIDE) PUBLIC ACCESS IS NOT RECUIRED UNISEX N/A ACCESSIBIUTY REQUIREMENTS: THE AMERICANS W/ DISABILITIES ACT - 1942 CODE SYNOPSIS S.F. BREAKDOWN LEVEL: 1 GROSS AREA: 0 • 2 *3a DOES KT 1110.110S 115 uNRIPROVED AREA 2. SALES AREA: locums SALES R X* ELEVATOR, PUEILIC STA, It FITTING ROOM 3. STOCK AREA: MACES STOCK/STaaNG, CIFIFICE(S). tAvioraerm ODT CORRICIORS • al1SMrTR 4 . AREA: S) 6. IANNIP11011E0 AWEA: ALL 'Pea JOINICIONED !LAND 4 iD LARD S. LINEAR FRONTAGE 11CLIR115 ALL UMW IIllelI1rKE MO, 11.11111114. Pret TO 111801111ML Pet 5.686 SF 1,217 s, OCCUPANT LOAD OCCUPANT 1 FACTOR LOAD s, 2.867 sr Lam_ 30 30O 153 144 4 AREA CALCULATIONS Limited brans LIMITED STORE PLANNING, INC. d /b /a STORE DESIGN & CONSTRUCTION Three Limited Parkway • Columbus, Ohio 43230 Telephone: 614.415.7000 • Fax: 614.415.7349 THE LIMITED STORE NO. 00688 SOUTHCENTER SPACE NO. 100 633 SOUTHCENTER MALL SEATTLE, WA 98188 S TENANT'S REPRESENTATIVES PROJECT MANAGER: CONSTRUCTION COORDINATOR: PROJECT DESIGNER: PURCHASING AGENT: GENERAL CONTRACTOR S1- 1RADER- MARTINEZ CONSTRUCTION, INC. MIKE COOK 2030 N. - WY . 8cIA, SUITE 82 SEDONA, AZ 86336 (928) 282 -7554 LANDLORD W ESTF I ELD CORPORATION 11601 W I LS1-1I RE BLVD., 12T1 --1 FLOOR (310) 575 -5918 LOS ANGELES, CA 0 10025 (310) 478-4456 CONSULTANTS ARCHITECTURAL 51 IREMSI - LOCK ARCI- 1ITECTS INC. 6130 S. SUNBURY ROAD SUITE 100 (614) 545 -4550 MECHANICAL / ELECTRICAL/PLUMBING 1-18K CONSULTANTS, LTD 171 CI- JARRING CROSS DRIVE SOUTI --I W ESTERV I LLE, 01-110 43081 (614) 882 - 11gq STRUCTURAL PAUL J. FORD 250 EAST BROAD STREET SUITE 500 COLUMBUS, 04 -110 43215 (614) 221 -6679 KEN C1- IRISTOP1• -IER (614) 415 -7350 DEBBIE 1- IENNOSY (614) 415-72q7 SAM FUNG (614) 415-7403 LEANNE MAMPIERI (614) 415 -1452 JOSE 1- 4ERNENDEZ r T ) 1 r. X0• 32,42 LSD&C PROJECT NUMBER: 00043770 issued: OCTOBER 16, 2003 BID DATE: NOVEMBER 27, 2003 REVISIONS MANN S: MBE Mr: • rrrc1cA'Ts urC •E • TO - 415 SKIT *NOrCATES 140 qtvoSON n ■4S Smft COVER SHEET A00.0 • 2. THE CONTRACTOR SHALL REVIEW ALL. DOCUMENTS AND VERIFY ALL DIMENSIONS AND FIELD CONDITIONS AND SHALL CONFIRM THAT WORK IS BUILDABLE AS SHOWN. ANY CONFLICTS OR OMISSIONS, ETC., SHALL BE IMMEDIATELY REPORTED TO THE LSD4C PROJECT MANAGER FOR CLARIFICATION PRIOR TO THE PERFORMANCE OF ANY WORK IN QUESTION. 3. WHEN CONTRACTOR ACCEPTS DELIVERY OF ALL ITEMS NOTED ON PLANS WHETHER IN CONTRACT OR NOT IN CONTRACT, WE SHALL BE RESPONSIBLE FOR LOSS AND /OR DAMAGE TO THESE ITEMS. 4. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE DURATION OF THE WORK ALL EXITS, EXIT LIGHTING, FIRE PROTECTION DEVICES AND ALARMS IN CONFORMANCE WITH ALL APPLICABLE CODES AND ORDINANCES. 5. DURING ALL PHASES OF WORK, DO NOT DISTURB THE DELIVERIES AND FUNCTIONS OF ADJACENT AND NEIGHBORING TENANTS. 6. 'TYP.' MEANS THAT THE CONDITION IS REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT. UNLESS OTHERWISE NOTED, DETAILS ARE KEYED AND NOTED 'TYP.' ONLY ONCE WHEN THEY FIRST OCCUR. 7. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DRAWINGS. 8. ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER OTHER DRAWINGS FOR LAYOUT DIMENSIONS AND NUMBER OF ITEMS PROVIDED. UPON DISCOVERY OF DISCREPANCIES BETWEEN ARCHITECTURAL DRAWINGS AND ENGINEERING DRAWINGS, OWNER'S PROJECT MANAGER SHALL BE NOTIFIED AT ONCE. 9. DIMENSIONS 514OWN ON PLANS ARE TO FACE OF GYPSUM BOARD, CONCRETE COLUMNS OR GRID LINES AND FACE OF EXTERIOR MASONRY UNLESS OTHERWISE NOTED OR DETAILED. 10 CONTRACTOR SHALL, IN THE WORK OF ALL TRADES, PERFORM ANY AND ALL CUTTING, PATCHING RESTORING, REPAIRING AND THE LIKE NECESSARY TO COMPLETE THE WORK AND RESTORE ANY DAMAGED SURFACES RESULTING FROM THE WORK TO THEIR ORIGINAL CONDITION. ALL ROOF PATCHING SHALL RETURN AREA TO "LIKE NEW" CONDITION. PRIOR TO PATCHING, G.C. TO VERIFY ANY ROOF WARRANTIES WITH LANDLORD. EACH CONTRACTOR SHALL LEAVE THE SITE IN A NEAT, CLEAN AND ORDERLY CONDITION UPON THE COMPLETION OF 14I5 WORK ON A DAILY BASIS. ALL WASTE, RUBBISH AND EXCESS MATERIALS SHALL BE REMOVED FROM THE SITE PROMPTLY. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL TRASH, INCLUDING OWNER - FURNISHED ITEMS AND TRASH GENERATED BY OWNER'S CONTRACTORS FOR THE DURATION OF THE PROJECT. 12. CONTRACTOR SHALL PROVIDE TWO FIRE EXTINGUISHERS (ONE EACH IN SALES AND NON - SALES) OR AS REQUIRED BY FIRE MARSHALL. VERIFY EXACT LOCATIONS WITH PROJECT MANAGER PRIOR TO INSTALLATION. EXTINGUISHERS TO HAVE A RATING OF NOT LESS THAN 2 -A OR 2- A/10BC WITHIN 75' TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING DURING CONSTRUCTION. 1. ANY DISCREPANCIES BETWEEN THE EXISTING CONDITIONS, DOCUMENTS, AND THE ACTUAL FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE LSD$C PROJECT MANAGER BEFORE PROCEEDING WITH ANY WORK. 13. A 4.4' CLEAR AISLE SHALL BE MAINTAINED THROUGH ROOMS TO EXIT DOORS AT ALL TIMES. 14. NO FOOD, ALCO440L OR SMOKING IS TO BE STORED, SERVED OR CONSUMED ON THE PREMISES. 15. ALL SECURITY DOOR AREAS TO BE PROVIDED WITH A KEY LOCKING DEVICE 50 AS TO ENABLE DOOR TO BE LOCKED IN THE OPEN POSITION AND REMAIN UNLOCKED DURING BUSINESS HOURS (WITH THE EXCEPTION OF THE REAR SERVICE DOOR). 16. ONLY PANIC HARDWARE APPROVED AND LISTED BY THE STATE FIRE MARSHALL SHALL BE INSTALLED. 17. EXIT DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING 50 OR MORE PERSONS. lb. DOORS OPENING INTO ONE -HOUR FIRE - RESISTIVE CORRIDOR SHALL BE PROTECTED WITH A CLOSURE AND A SMOKE OR DRAFT STOP FIRE ASSEMBLY HAVING A MIN. 20 MINUTE RATING. 19. EXIT SIGNS SHALL BE ELECTRICALLY ILLUMINATED AND THE TWO LAMPS SHALL BE ENERGIZED FROM SEPARATE CIRCUITS. ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES WIRING SYSTEM. IN THE EVENT OF FAILURE OF THIS SYSTEM, ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY BACKUP SYSTEM. EMERGENCY LIGHTING SHALL GIVE A VALUE OF MINIMUM ONE FOOTCANDLE AT FLOOR LEVEL, UNIFORM THROUGHOUT EGRESS PATH. 20. FIRE DAMPERS SHALL BE PROVIDED BY MECHANICAL SUBCONTRACTOR WHERE DUCTS PENETRATE FIRE -RATED WALLS OR CEILINGS. REFER TO MECHANICAL DRAWINGS. 21. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT WE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE, OR EFFORT. 22. ANY MODIFICATIONS TO EXISTING SPRINKLER/ALARM SYSTEM AND EXTERIOR SIGNAGE WILL BE UNDER SEPARATE COVER(5) AND PERMIT(S). GENERAL NOTES T seggERA, CL P4TRACTOR SHAi;. ARRANGE FOR AL. INSPECTIONS AND FURNISH TIRE STORE '"A+wAGER wIT44 THE CERTIFICATE OF OCCUPANCY _ ALSO, PR01/1DE A LIST OF INAM, AMR :EWES AND TEL PARBERS FOR At.. SUBCONT'RA TORS, MCuuDaMC, A:... DER PROVIDED SUBCONTRACTORS. t3OT1 ilErS TO BE hour-ED M SEPARATE PIC'.RE rRAME5 (8-1/2 x 11 ') ON REAR OF MANAGERS OFFICE '70L7R A' FACE AEI •"r ANiG O~E C O v TO OWNER'S PROJECT MANAGER_ 2- Y'wE GENERA, COOS' RACTOR 514►L4.- ALSO FURNESAI COPIES OF 5 •D =TE G TO TI 4E SERVICE CORPORATION, 3 PRrc'iIt SORE OF94P4G - •lE G_C_ S RFSP NEOB .E TO ARRANGE FOR • .'. r'F 1ACIE 90•4 J1NC GOK"RAC - OR "O BA► ONCE i.' VA C S'S"E! REFERHlC • ASR BA..AIyC NG c NC PROCEDURES "IIECANISCAL .7RAm1NMf.5 CONTRACTOR 9401/4_. PRCV' n►€ .ANCORD Ali) OWNERS PROJECT MANAGER Iri?i4 A CQa'Y OF ' 14E EIA-ANCE REPORT IF IM) Br ,Arco niE G.0 SiAALL SECURE T E NECESSARY APPRCNAL OF WIPES SPIOMKLER v1 ' FIRE INSURANCE CAS S. G C Sr+A►... 't MEI ALL KEYS ' 0 STORE MANGER CLEARLY MM HG E. 4 KEr ICIENTIFICAviON i. G.0 "'ROME A PROFESS40414. CL.EP. SEIRVMGL FIQt TI• E STOLE AT 'ME Tr" CP STILE Saki. 1E CLEANED AGAIN* AFTER PERICSAPOSINIG OF THE ST1aRF, AS READ TO RETURN TO A "DIEr-Fl ' cowman mat TO O E* L 7 ir.C. 94AL,. EXPLAIN OPERATION Cr ALL rIEDIAMKAL SYSTEM TO mum PLAIN Fit M Irwc 9*.4. urvtATE ASSEREVE, AND 11115TALI. usroaspos Gre1ER SIPPLED FIXTURES t 4EM9 LIRE AAWIEr R'1810W E 711%1011 t G c "di REPCNISIELE TO mama (ti) 30 TAM TOMOS CONTAINER F *Lk earn L. .00Q4416 MATERIALS went TO snot cream ar ,T8t TO SE >E ONE r; Ab"OLIcr S1ET pr DRAIMPi6 WALL WI S 0 RIb1 TM MAC TURNOVER REOUIRENTS PLAN DETAIL REFERENCE SHEET NUMBER PLAN SECTION REFERENCE SWEET NUMBER SECTION DETAIL REFERENCE SHEET NUMBER ELEVATION REFERENCE SHEET NUMBER CABINET/FIXTURE TYPE "' BLDG SECTION REFERENCE---. xx x ELEVATION HEIGHT TARGET-4. fi - Y' A.F.F LOCATION IN SPACE -• LOCATION LAYOUT ORIGIN-. LAYOUT POINT WALL TYPE DOOR NUMBER CODED NOTE REVISION SYMBOL REVISION CLOUD CEILING HEIGHT CEILING FINISH ADDITIONAL NOTES --- FINISH CALL-OUT ADDITIONAL NOTES- NOTE ROOM NUMBER WALL FINISH CALL -OUT -• BASE FINISH CALL -OUT --• CABINET FINISH GALL- OUT TRIM FINISH CALL-OUT--• FLOOR FINISH CALL- OUT ---- • 0 • FINISH NOTE NOTE FINISH ,J ---- -• number B C T F ROOM ucl cabinet trim floor SYMBOLS LEGEND ABV A.F.F. ALUM BD BLKG 81W CALC.S CLG COL CCNC CONSTR CONT G.T.F. G/W EA ELEV ELV EQ EXIST EXT ABOVE ABOVE FINISH FLOOR ALUMINUM BOARD BLOCKING BACKHRAP CALCULATIONS CENTERLINE CEILING COLUMN CONCRETE CONSTRUCTION CONTINUOUS CUT TO FIT CA5NWRAP EACH ELEVATION ELEVATOR EQUAL EXISTING EXTERIOR F.G.D. FINISH CABINET DIMENSION FD FLOOR DRAIN F.D. FIELD DETERMINED FIN FINISH FL FLOOR FLG FLOORING FLUOR FLUORESCENT FRT FIRE RETARDANT TREATED F.O. FINISHED OPENING F.R. FITTING ROOM G.G. GENERAL CONTRACTOR GYP (BD) GYPSUM (BOARD) H.G. HANDICAPPED H .D.F. HIGH DENSITY FIBERBOARD MGT HEIGHT HORIZ HORIZONTAL HR HOUR INCAND INCANDESCENT INT INTERIOR LSD4C LAV L.L. M.D.F. MAX MECH MFG MISC MIN MIL N.P. N.T.S. O.G. OPNG PL PLEX PLYWD PREFIN P.M. RAD RE (REF) R.O. SECT 5HT 51M SQ STRUCT TEMP THRU TYP U.N.O. V.G. VERT Y.I.F. W/ WD W/O LIMITED STORE DESIGN 4 CONSTRUCTION LAVATORY LEASE LINE MAXIMUM MEDIUM DENSITY FIBERBOARD MECHANICAL MANUFACTURER MISCELLANEOUS MINIMUM METAL NEUTRAL PIER NOT TO SCALE ON CENTER OPENING PLATE PLEXIGLASS PLYWOOD PREFINISHED PROJECT MANAGER RADIUS REQUIRED REFERENCE ROUGH OPENING SECTION SHEET SIMILAR SQUARE STEEL STRUCTURE TEMPERATURE THROUGH TYPICAL UNLESS NOTED OTHERWISE VOLUME CONTROL VERTICAL VERIFY IN FIELD WITH WOOD WITHOUT ABBREVIATIONS airing 4 1 +r- HM. F Point C Highland x ', 01 a1r Palk Siruce Pink _ • OrmenC ■ MIr i S7■nw.Iu, - _L 43 - . L. *. Piet Soi it' - T lisersom - ' - . 3 r - Amos • ;__ SaeTar. r 21311t31 � * -, ni. 4 • I 6 T $15 SOUTHCENTER 833 SOUTHCENTER MALL SEATTLE, WA 98188 S is' mats' I sour 3 I Lore Asir VICINITY MAP KEY PLAN FRONT APPROACH, PUSH SIDE FRONT APPROACH PULL SIDE >e= z F " a CND m ELEVATOR: OFF- CENTERED DOOR 48' MIN 2A' M 610 '1 1220 '1 610 z # - z CV CLEAR WIDTH OF AN ACCESSIBLE ROUTE GENERAL ACCESSIBILITY CONDITIONS ARCHITECTURAL A00 PROJECT INFORMATION. A00.0 COVER SWEET A00.1 RESPONSIBI SCHEDULE A00.2 FINISH AND DOOR SCHEDULES A00.3 NOT USED A01 TEMPORARY WORK A01.I DEMOLITION PLAN A01.2 DEMOLITION PLAN A01.3 NOT USED A01.4 NOT USED A01.5 NOT USED A01.6 NOT USED A01.7 NOT USED A02. CON5TRUCTION A02.1 CONSTRUCTION FLOOR PLAN A022 CONSTRUCTION FLOOR PLAN A03 REFLECTED CEILING, A03.1 NOT USED A032 NOT USED A04 REFLECTED LIGHTING A04.I REFLECTED LIGHTING PLAN A04.2 REFLECTED LIGHTING PLAN A05 FLOOR 4 HALL FINISH A05.I FLOOR 4 WALL FINIS" PLAN A05 FLOOR 4 WALL FINIS" PLAN A06 PRESENTATION 4 FIXTURE PACKAGE A06.I PRESENTATION 4 FIXTURE PLAN A042 PRESENTATION 4 FIXTURE PLAN A07 INTERIOR ELEVATIONS A01.1 INTERIOR ELEVATIONS A07 2 INTERIOR ELEVATIONS AO6 STOREJ`RONT CTRUCTION A08.1 STOREFRONT ELEVAT A0b.2 STANDARD STOREFRONT DETAILS A08.3 STOREFRONT SECTIONS 4 DETAILS A08.4 STOREFRONT DETAILS AO8.5 STOREFRONT SECTIONS 4 DETAILS A08.6 STOREFRONT SECTIONS A09 VERTICAL O ULA TION A01.1 NOT USED A10 CABINET ASSEMBLY * MILL PAGICAef A10.1 NICHE LEDGE DISPLAY DETAILS A10.2 FLOATING DISPLAY WALL DETAILS A103 AA/AN 4 BA/BW CABINET DETAILS A10.4 NOT USED A10.5 BACKNRAP FOCAL DETAILS A10.6 CABINET AND CONSTRUCTION DETAILS All BACICYlRAP /CRAP Y A11.1 4 TERM CASHWRAP ASSEMBLY A11.2 BACKWRAP ASSEMBLIES All 3 NOT USED A11.4 NOT USED A11.5 4 Tal 1 M AIO CUISINi!N ASEBRX At1 CONSTRUCTION DETAILS Al2.I PARTITION DETAILS Al2.2 FLOOR TRANSITION DETAILS Al2.3 OILING AND LIGHTING DETAILS Al2.4 DOOR /JAMB DETAILS Al2.5 COL.UrN AND BASE DETAILS ,A13 CONSTRUCTION DETAILS - ROOMS A13.1 WIC PRIVATE TOILET / JAN CLOSET A13.2 STANDARD FITTING ROOM DETAILS M3.3 HANDICAP FITTING ROOM DETAILS A13.4 MIRROR DETAILS /414 PRESENTATION PACKAfiE ASS13IB Y A14.1 STOG7CRO M SEWING DETAILS A142 PRF5B4TATION FIXTURE DETAILS A14.3 PRESENTATION FIXTURE DETAILS A14.4 MOT USED A15 5eEC flCAaIO5 M5.1 SPECIFICATIONS A152 SPECIFICATIONS rA5.3 SPECIFICATIONS SEPARATE PERMIT R _QU1R CD FOR= SNECH AZITICAL tilkLEC 0 PL UVIar ► 0 GAS ptpiP G crrY OF T UX L.A BLU1:LD$NG DIVISION MEP STANDARDS FAO .ENGINEERING SPECIFICATION E00.0 ENGINEERING SPECIFICATIONS ELECTRICAL EDI ELESTRICAL SPECIFICATIONS E01.I ELECTRICAL SPECIFICATIONS E0 2.1 ELECTRICAL POWER PLAN NOTES E02.2 ELECTRICAL POWER PLAN E02.3 ELECTRICAL POWER PLAN E03 ELECTRICAL LIGHTING 109.1 ELECTRICAL LIGHTING PLAN AND NOTES E03.2 ELECTRICAL LIGHTING PLAN E03.3 ELECTRICAL LIGHTING SCHEDULE 1=04 ELECTRICAL DETAILS E04.1 ELECTRICAL DETAILS E04.2 ELECTRICAL DETAILS E05 ELECTRICAL SCHEDULES EO6.1 ELECTRICAL PANELS AND RISER DIAGRAM FIRE PROTECTION F0 SPRINMCLER F02.1 SPRINKLER PLAN 4 SPECS F022 SPRINKLER PLAN MECHANICAL 1101 'MECHANICAL SPECIFICATIONS M01.1 MECHANICAL SPECIFICATIONS 1102 agiAi NICAL MO2.1 MECHANICAL PLAN MO22 MECHANICAL PLAN M03 MEr AL DETAILS M03.1 MECHANICAL LOAD CALLS AND DETAILS 11032 MECHANICAL DETAILS M04.1 MEOW UNIT SUPPORT PLAN PLUMBING P01.1 PLUMBING SPECIFICATIONS .LNG P02.1 PLUMBING PLAN RB P DETAI P03.1 PLUMBING ISOMETRICS 4 DETAILS TEMPERATURE CONTROL AND HVAC WIRING DIAGRAM TOO TB1 ERATURE CONTIaOI TC0.1 TB1PERA LIRE CONTRA. WIRING DIAGRAM •J ' - -` - t .il1:11'1 _ *� T, E ♦ . t_ .� - - - 1-- 1E- 1MIrSt o1or.m•c5 sorancamose Mit pis POO uSE Oft • WE SPIT «O. . ..W W ssut writ , 4t mot um ortmere roe ust v. • OsxtiEtwr POOKCT Wt a „r * Marry not WM Or mmrst m ____- s •".a S•Ca'Carefork a a- gonna. *►Tatar. Or appleME11 r" 1ojocT s reemo ri ame ecomptl► r0 ale t$s EiPINESSio yorren r+► r unn sran 1 1,N66041. wc.... a/1/. JaPRIS snow maw xlr4 CONSTIOurVerr ("1.30C WISE O IOSIMS 11110 SPICWIt*nOxS ME '1"E M' 'E*V' Or .sIMC wit 9 "NCI OMPLIPt* , -, X11 QA 4ISED .?n wow vier* x 10iISCr MU"' rw1TEe IMINUNDIV WOW kW. 'NO 410 OR 111 1SE csam.cS 11.Q qEc *rttiprns swats. t rram amormotor rME sorrniss •rI*ovwrtismos Or rig LSI1[.. N . OrmoEMLS Gr itiregoocrors Or 111113E O11111111MS aO0 S/KO 1 CATIO16 1,05 E OFOIONIED 10 MX WON COr'I,txlpx ar 'WA w11E1ttIME 1 VSE. 61114133 aCIEte I ' "ME Mt, COPPTIKot NOrMCL iMESE IlrrerrlKS • Ora s1nECm** leS a11IE COMPONCPWO a syM aucT rc aminiacor movicTtow as r. mar jest. SEC_ 'It Or Ntt Cn►'1twi r at% ' s S.C. x5 x OUNIOs Otalrill. •!!St MUM OS "NE eons f. rreaOr t 11'w atone. Tor rim mit r"11DxEC11Pi saws, wnrav r ar'nw11p . r•t ONE t. POOL ■.ICEuEw - a■.R COOP091101 OF 1POCE S. M MUMS Of OK OE9itr. 4116111 S111C** 1 00 11 EC10a1, ellOMMINOORE1 IMF Of 1 0101111103 111 IIPECMCAMONS may QUO w Malaga Or COMIPSOCINSW /Ml1wi 't1Q . 'MVO* 11ows-T!!• 1111t`r17_ FILE COPY I understand that the Ran Check ova!s are subje to errcrs and crr ssi,^.a .*'. approval of Mars does rct aulho :ze the - !atton of - y adopted cod.e or ors:: "a° ^ - Rem:: D : - • 1 tractor's copy of apprc. d p :a . By Permit No. ,I Amy • DRAWING INDEX PROJECT SCOPE: THIS PROJECT IS THE DOWNSIZE/FULL REMODEL OF THE EXISTING THE LIMITED" STORE. WORK IS TO INCLUDE, BUT NOT BE LIMITED TO, THE PARTIAL REMODEL OF EXISTING FLOORING, WALL CONSTRUCTION, LIGHTING AND CEILINGS. A PORTION OF WE STORE IS BEING RETURNED TO THE LANDLORD. NOTE: USAGE IRSTORY: THE LIMITED PROPOSED USE: THE LIMITED SPACE NUMBER(S): TO BE USED EXC 10 IVELY FOR RETAIL SALES SCOPE OF WORK STORE TYPE: THE LIMITED RETAIL APPAREL SALES LOCATION: LEVEL: SOUTHCENTER 1OF1 APPLICABLE CODES: WASHINGTON STATE BUILDING CODE - 1997 WASHINGTON STATE PLUMBING CODE - 2000 WASHINGTON STATE MECHANICAL CODE - 1997 WASHINGTON STATE ELECTRICAL CODE BUILDING OCCUPANCY USE GROUP: M - MERCANTILE CONSTRUCTION CLASSIFICATION: TYPE: 2N FIRE PROTECTION DEMISING WALL I HOUR SALES/NON- SALES WALL 0 CEI UNG 0 COLUMNS 0 SPRNCLERED: FULLY SPRINKKLERED OCCUPANT LOAD: (4,44q/30) + (1,217/300) - 153 REQUIRED EXITS: NUMBER: 2 MAXIMUM TRAVEL DISTANCE: 200' RESTROOM REQUIREMENTS: WATER CLOSETS: 1 REQUIRED FOR MALE 1 REQUIRED FOR FEMALE LAVATORIES: I REQUIRED FOR MALE I REQUIRED FOR FEMALE E URINALS N/A DRINKING FOUNTAINS DRINKING FCUNTAN PROVIDED PUBLIC ACCESS IS NOT REQUIRED UNISEX N/A ACCESSIBILITY REQUIREMENTS: THE N ERicANs w oss. 1LmE5 ACT - 194x CODE SYNOPSIS S.F. BREAKDOWN LEVEL: t GROSS AREA: - 2.3. DOES Nor •C LURE ss AREA 2. SALES AREA: SCUMS WILES FL , . ELEVATOR weds STAB e1r ) I FT4"fi11%. mccrre, a STOCK AREA: OFFICE(S),, LAVATORITS) EST COISMOICIRS r 01111111wTER 4. 1/1SC. AREA: S) & UNWIPROVIED AREA: ALL sow' 411AlE01ECt !!I► Mop IIIETWIIIED 1O ND O. SEAR FODIITA MUM ALL MOIR 4 wog wartart Pot TO if Inept 1 5, 686 sF 4 469 S.F . 2T7 st SF . 2,867 SF 40 LF. OCCUPANT LOAD OCCUPANT FACTOR LOAD 300 153 04Q AREA CALCULATIONS limited brans LIMITED STORE PLANNING, INC. d /b /a STORE DESIGN & CONSTRUCTION Three Limited Parkway • Columbus, Ohio 43230 Telephone: 614.415.7000 • Fax: 614.415.7349 THE LIMITED STORE NO. 00688 SOUTHC ER SPACE N0 . 108 D 633 SOUTH 'TER MALL SEATTLE, WA 98188 S TENANT'S REPRESENTATIVES PROJECT MANAGER: CONSTRUCTION COORDINATOR: PROJECT DESIGNER: PURCHASING AGENT: GENERAL CONTRACTOR 51- TRADER- MART INEZ CONSTRUCTION, INC. MIKE COOK 2030 W . 1-I W Y . 89A, SUITE B2 SEDONA, AZ 86336 (928) 282 -7554 LANDLORD W ESTF I ELD CORPORATION 11601 WI LSl-I I RE BLVD., 12T1 --1 FLOOR LOS ANGELES, CA 90025 (310) 478-4456 CONSULTANTS ARCHITECTURAL S REMSI -LOCK ARC1-1 I TECTS INC. 6130 S. SUNBURY ROAD SUITE 100 (614) 545 -4550 MECHANICAL I ELECTRICAL/PLUMBING -4BK CONSULTANTS, LTD 171 0- TARRING CROSS DRIVE SOUTI -I W ESTERV I LLE, 01410 43081 (614) 882 --1199 STRUCTURAL PAUL J. FORD 250 EAST BROAD STREET SUITE 500 COLUMF3uS, 04-410 43215 (614) 221-667c1 t ' J __j 1 !, J KEN C1•-I R I STOP1 -I E R (614) 415 -7350 DEBBIE I- IENNOSY (614) 415 -7297 SAM FLING ( 614) 415-7403 LEANNE MAMPIERI (614) 415 -1452 JOSE 1- IERNENDEZ (310) 575 --5918 t / I ITECT 7 -1( GEwwo s. dock STATE OF NtSHws'FON eN 1)403 32/v LSD &C PROJECT NUMBER: 00043770 ISSUED: OCTOBER 76, 2003 BID DATE: NOVEMBER 27, 2003 REVISIONS i lialrfalfs" OISE • CA + 1 11t143 1 f0 `hos sr+EET 8'f I#: • eiCiC.NrtS 0410 ''.S Spite' COVER SHEET A00.0 • ,. S le Is III • • I a • 4 S A i I 4 1,i olg I li § .. . .4 tei Hr. 11 II 1 . . . g - • y� n • o f-- 1 • e I I p 2 F o � M A 3 0 r m 0 z 0 0 0 moor a _ I A A gif:1 N rn C '• q m -HH n Red ` I i • • t i P r z 5 t, % I 4 0 r -m t r % 0 7D i 3 -- t 6 1 i ill 2 4 , i ; i . g E I Ei . 0 rn z rn r • • • 11111111111111111111111111111111111111111000OR 11• 111111111111111111100111111111110110101111 � . 0 I • • ••• U! 1= VP nd T -4 it • • • U 'IA 5 .1 b RT f g 4 § 2 a g R - _1 z 5 m iNig , t m c D g CIS ,m A P % 4' ••• •••.,.• I I I •• e:•1 • • 4 m Crt o' 0 O 00000 ' 0 • • • • • • • •• 1 ;° 0 4_000040i I I 4 PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 2 SCOPE: REMODEL /DOWNSIZE I PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD �CC PROJECT : 00043770 A/E PROJECT #: 0100688 032Fb 03341/03132 PRQHIBi11QNAti REUSE THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE, THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS ( PR"LSOHIBITEDC " }. D AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., 0 /B /A LIMITED STORE DESIGN AND CONSTRUCTION THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSOC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. COPYRIGHT 14QIICt; THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC, 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELLMENTS Of THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE Of THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSAIION Of CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY. Limited brands LIMITED STORE PLANNING, INC. d 1 b /a DESIGN & CONSTRUCTION I hree tinted ted Parkway . Columbus, Ohio 4323 I el €Bone. 614,415 /000 Fax: 614 4'15./349 r t .). , - LNWVII .3 �CE irt)i �cf r and:, c Tfl 7 R I T v s • - oc -.' z • • 1 c m o— *m g-&0 0 21T; ! t-4 C= rn 3 co —1 0 � 17 A 0 NOT USED r NOT USED FITTING ROOM N.G. FITTING ROOM SALES /NON -SALES MANAGERS OFFICE LAVATORY SERVICE DOOR STOCK ROOM DOOR NOT USED NOT USED 'A' TBMPERED GLASS B4TRY DOORS ENTRY DOOR IS SUPPLIED 4 INSTALLED BY GLAZING CONTRACTOR. TEMPERED GLASS DOOR AS MANUFACTURED BY 'TEMPGLASS' (OR OWNER APPROVED EQUAL), SIZE AND THICKNESS AS SHOWN. 12' NIGH BOTTOM RAIL (RECTANGULAR PROFILE) WITH 2' x 6' PATCH FITTINGS WITH PIVOT, BRUSHED STAINLESS STEEL FINISH TO MATCH SIDELITE BASE. (NOTE: TOP OF BOTTOM RAIL TO ALIGN WITH TOP OF SIDELITE GLAZING BASE.) BRUSHED STAINLESS STEEL TOP DOOR PATCH, G.R. LAURENCE CO. (2503 E. VERNON AVE., LOS ANGELES, CA 90058, PHONE: 800- 42I -6I44) sP1420A56, AT PIVOT CORNER TO NAVE 2 3/4' SETBACK TO BE COMPATIBLE WITH G.R. LAURENCE *P$44065 2 3/4' SETBACK BRUSHED STAINLESS STEEL SIDELIGHT MOUNTED TRANSOM PATCH WITH PIVOT INSERT. GLAZING CONTRACTOR TO SUPPLY AND INSTALL THE FOLLOWING ITEMS: STAINLESS STEEL DEADBOLT AND STRIKE PLATE BY ASSA FLUSH MOUNTED IN FLOOR; ONE SET TO LOCK DOOR CLOSED. CONTRACTOR TO PROVIDE AND INSTALL FULLY CONCEALED FLOOR CLOSER WITH HYDRAULIC OPERATION AND FULLY ADJUSTABLE HOLD OPEN; COORDINATE CLOSER SPECIFICATION WITH DOOR SUPPLIER; ACCEPTABLE MANUFACTURERS ARE DORMA AND RIXSCN. CYLINDER LOCK BY U- CHANGE LOCK CO. (1640 W. HIGHWAY 152, MUSTANG, OK. 73064, PHONE: 405 -376 -1600) WITH STAINLESS STEEL FINISH THUMB TURN BY LORI. DOOR LOCK TO BE KEY OPERATED FROM OUTSIDE WITH THUMB TURN INSIDE. NOTE: EACH ENTRY DOOR TO RECEIVE THIS SET OF HARDWARE 4 ALL ENTRY DOORS TO BE KEYED THE SAME. CONTRACTOR TO PROVIDE I INSTALL STAINLESS STEEL PUSH PULL HARDWARE W4130 SET *G33112A BY CHMI. ALL DOOR HARDWARE IS TO BE APPROVED BY LIMITED BRANDS INC. CONSTRUCTION MANGER PRIOR TO INSTALLATION. 2' - 2' -I1 -6" 3' - 0" 3' -0" 3' -G" 3 1 -` r 3/4 "x5' -D "xI 3/4" I /2 "x5' -0 "xi 3/4" x 7' -0" x 1 -3/4" x 7' -O" x 1 -3/4' x 7' -0' x 1 -3/4' x 7'-0" x 1 -3/4" x 7' -0" x 1 3/4" WOOD /SSV WOOD /55V HOLLOW METAL HOLLOW METAL HOLLOW METAL HOLLOW METAL HOLLOW METAL OOD /PREFI N WOOD /PREFIN 1- IOLLOW METAL HOLLOW METAL HOLLOW METAL HOLLOW METAL HOLLOW METAL NONE NONE NONE 90 MIN. NONE NOT USED DOOR: 1 we UNFINISHED HOLLOW METAL DOOR, FRAME AND HARDWARE TO BE SUPPLIED, INSTALLED, AND FINISHED BY GENERAL CONTRACTOR I: I. HINGES: STANLEY NF17q (1 - I/2) PAIR PER DOOR. 2. PUSH PLATE: maw ON SALES SIDE. 3. KKKPLATE: CENTER AT BOTTOM OF DOOR ON SALES SIDE. 4. DO :1R PULL: MOUNT ON NON - SALES SIDE. 5. CLOSER: DOOR MOUNTED ON NAIL -SALES SIDE WITH TAW BOLTS. 6. HOLD OPEN HDAG/DOOR STOP: LOCATE IN NON-SALES AT FLOOR CLOSE TO WALL. 7. BEl ALARM LAVATORY DOOR; 1 3/4' UNFIRED HOLLOW METAL DOOR, FRAME AND HARDWARE TO BE SUPPLIED, INSTALLED, AND FINISHED BY GENERAL 1. HINGE, : STANLEY sF17 (1 -1/2) PAIR PER DOOR 2. PRIVACY LOClC51ET: SOILAGE 11M05, PRIVACY FUNCTION_ 3. cIOTHMG 40:14; BRASS WORIK5 1500_ (OR EQUAL) AUSIN rI FINISH, CENTER AND MOUNT ON LAVATORY SIDE OF DOOR ! 72' A_F.F 4. DOOR STOP: COITIEROAL GRADE, 24D BRUSHED STAI41.155 STEEL, WALL MOUNTED DOOR STOP AT LEVER HOGHTT. 5. LOS PP FILE (H.C. TYPE) ALL MIar1 THIRMCILD. 6_ GLASS r11RROR - 2O' x 58' (ALL EDGES OF P11RR R TO RECEIVE SLIGHTLY CURVED EDGE WITH SMOOTIED OR PC1-151ED FMS+) WITH TOP AND BOTTOM 'X CHANNEL (SET MIRROR N MASTK), CBNTBR AND MDUNT ON LAVATORY SIDE OF DOOR wrn4 TOP OF !' • 70 A.F.F. GFRCE DOOR: OFFICE DOOR IS TO RECEIVE (2) 6 1/2' X 1I' PICTURE FRAMES BY G.C., MINTED AT EYE LEVEL. TO OFFICE SIDE OF DO R_ OFFICE lXXt TO BE KEYED SEPARATELY_ 41ARONALRE: • KEYED worse( - may mimes X oak (KEYED AL/E ): MANUFACTURED Br SO4 AGE_ • JAMES - EIM (1 L'2 PAR) STARLESS STEEL FIIIREK !'1A luFACTU ED Br STaM E`►'. • aorta+AMG 'w - 804 X 425, INSTAL. A' mar. C.a ON OFFCE SIDE OF f:COR AT Sr A-F - F -; r1M.FACTURED B N001DNO IO ▪ ALi1W' O E#R - PAW MANUFACTURED BT Lai . Aurorae' t30C PLATT - >r' x s>~', MOLOCED FROM eOTThr+ of DOlat ON NM-SALES SOL MANUFAC IRED eT ROCKWaaD - DOOR STOP - 46i X Lek MANUFACTURED FA>CT'.JRED BY ROSIN OD. "DACE DOOIa HARMARE 15 TO BE 51PPLED - _- 415 BY GBERAL COIL ACTT UNLESS RUUD Ors+I RWISE.. 1. Cj260L . .r r A sliTk - ON STORE SOIE 2- Ply 140LE CINTEP IM 1202R AT SR' &F_F. 3 IOICEPL ATE: >/, NIKN1 B,' IRalL MCTii, MUM STAIA.E!, 5 STEEL, mum r mar Wr rc r aF DWI ON SWINE SIDE 4 NLkR'eiJr'1' ' D ON MC7180E: t OOQR (IF 1183001111ED) TO PliEverr NAM S PERRIS1e6 NEA11 . SIMPIPIRS OR EXTBb10IR DOOR. i. Sim 3' x r6' wen itASnC F D WM d/IpC LETTER COMA K• AF F a MIME BE DOS. 7 OEUVIN? 7 '.S11i "SIT@! REFER TO SWUM COANNIA rat opcsrairot S r•aw mairmEmuen Lax SUPPLIED O► O ER MID +1sfi11.LED Br MEW ammercrakt CENTERED AT Air A.F-F. (OR AS Mom Br 'L7a1211 RIDAIONS rwoRNrliE LUIS CT1r1081e WHINES S 61111MIED DITw LavC 'K' STOCK ROOM DOORS HARDWARE • KEYED LOCKSET - D53PD RHODES X *624 (KEYED ALIKE); MANUFACTURED BY SCHLAGE. • HINGES - 885000 - 450 - 653, 11/2' PAIR PER DOOR; MANUFACTURED HY BOMMER. • ALUMINUM CLOSER - P1441; MANUFACTURED BY LCN. • ALUMINUM KICK PLATE - ID' X 42', MOUNTED 1' FROM BOTTOM; MANUFACTURED BY ROCIG'1 D. • DOOR STOP - 441 X U528; MANUFACTURED BY ROCKWOOD. DOOR AND FRAME TO BE 20, 45 OR 90 MIN. FIRE RATED TO COMPLY WITH LOCAL AND STATE CODES. PERIMETER OF DOOR IS TO RECEIVE A SMOKE GASKET. HARDWARE: • ALUMINUM CLOSER - P1461; MANUFACTURED BY LCN. ILLUSTRATION OF SCI4LAGE RI -LODES LEVER TYPE HANDLE TO LSE USED AS SPECIFIED ABOVE. (U.N.°.) Itiak METAL PANE. METAL REVEAL ACOUSTKAL CRAG "U PANEL Lou. PANEL IML' LAID. 2' x 2' I4ITE METAL REVEAL 2414' �''"1 - BEVELED 'AEI A.AR. ORMA SIP - r E FITTING ROOMS - SEE DETAIL G'A13.4 STOREFRONT - RJR TO PETALS - TO S.PPLAD VP maul 4 IPSTALLED S INJES APNEA MOI E CRS LAYS SEE "err mar 4 AE-A SNUBS AREA - OWE STOP WINE ENSPL A :r • ,AA-• JQT� PR 11111 kilitalle NONE MIDAMINIONNIMINIONMNIEIMINIC_ Milid11100111N1 I 01 I I I II IN I GI I N I & ai • la WIlp■-• • 1 IC) STOREFRONT ENTRY NOT USED 11".° M .I lard•ww. ,E Lt Mt 1 MU RR' MVO rurc V WY I ILA 1 ICAV. rAIrl I nu I I un now II c,uwt. r O rw i ua 1��Lr -I -. ^411 !'' ■■ `47 1 - 4 3. 1 •.r.I' e' f•• ■ '10'2 ^r '1 1 1 • STS (SUPPLIED WITH GRILLE) 1. • • • •w• r ■. • ■ UALItIdt• 1 I S. 4. Cz.C.. 1 U ekuvIut NU) IF 451 ALL SK&I Pi4 UIr1 bl DFCt AIL CA MA 1 CAI MAIL Cif- GRILLE STATING, "GRILLE MUST REMAIN IN FULL OPEN POSITION DURING STORE HOURS hNEN OCCUPIED BY THE GENERAL PUBLIC. GRILLE SMALL BE OPENABLE FROM STORE-WE WITHOUT USE OF ANY SPECIAL KNOWLEDGE OR EFFORT WHEN SPACE IS OCLUPIED' C ■. C"' OM • lAncrra I LAFCt 140u c, uu.urltu of THE c ks¢ PUR JC._ •` Z, r • 1z. • _ +111' • - 117r t" • EFFORT WHEN SPACE IS OCCUPIED bHALL. > romirin A ._..41 gm D 12.4 � 12.4 WAWA - � �! — .!S'/ _ - a v - DOOR SCHEDULE & HARDWARE GROUP C CODE P -I P -2 P -3 P -4 P-S MATERIAL PAINT FINISHg5 MANUFACTURER BENJAMIN MOORE BENJAMIN MOORE BENJAMIN MOORE BENJAMIN MOORE DESCRIPTION "LIMITED NATURAL ALMOND' AUQUAGLO GAL. FORMULA: OY 1 X 10, 13K b, OG 5, 'LIMITED LIGHT ALMOND' AOUAGLO 333 GAL. FORMULA: OY K BK 4, OG 2, GY 333 18, SEMIGLOSS. GY 2. 18, SEMIGLOSS "LIMITED NATURAL ALMOND' AUCUAVELVET 319 I8, EGGSHELL. GAL. FORMULA: OY 1 X 10, BK 8, OG 5, GY 2. 'LIMITED LIGHT ALMOND" AOUAVELVET 319 I13- EGGSHELL GAL. FORMULA: OY 16 BK 4 OG 2 GY 6. "LIMITED LIGHT ALMOND" 215 18, FLAT FINISH GAL. FORMULA: OY K 8K 4, OG 2, GY 6. NOTES/LOCATION. SALES AREA - METAL DOORS AND FRAMES NON - SALES AREA - WALLS, CEILING (AS RECD.), METAL DOORS AND FRAMES, FR AREA WOOD BASE. SALES AREA - WALLS, CEILING (AS INDICATED), WALLS NOT COVERED By CABINETS, WALL COVERINGS, MIRRORS OR SPECIAL FINISHES FITTING ROOM WALLS, SEE ELEVATIONS SALES AREA - GYP. BD. CEILING, SOFFITS AND FASCIAS, UNLESS NOTED OTHERWISE ON THE INTERIOR ELEVATION P-8 P -9 P -10 .m.PEN Imam!' Nornm_ NOIMPRIVIIII n..1 cm FC -4 FC -8 FG -9 FC -10 5-I 5-2 5-3 5-4 5-5 5-7 B-1 WC -I WC -2 WC -3 WC -4 WD-1 WD-2 G-1 SEMI GLOSS SEMI GLOSS EGGSHELL EGGSHELL FLAT FLOOR COVERINGS WOOD FLOOR VINYL COMPOSITE TILE 1/2' TILES PORCELAIN TILE HARDWOOD PLANK ELEMENTS CARPET SEALANIS/S AINS SEALANT (CAULK) SEALER WALL BASE PORCELAIN TILE ilARDMIOOD BASE RUBBER BASE STONE TILE WALL COVERINGS HARDWOOD r CLEAR GLASS BENJAMIN MOORE ARMSTRONG 12' X 12' VINYL TILE 'EXCELON' 1151901 'TAUPE' - IMPERIAL TEXTURE ONNOMMilliliWPMWPF!MFARigill -- - ^- , • • •• r - FG -7 PORCELAIN MOSAIC EF'�1i'Eir�i'Eri►�!I� PRE- FINISHED DARK BROMN STAINED HARDWOOD GROUT: LATICRETE *30 SAND BEIGE, UNSANDED 500 SERIES I/16' GROUT LINE - EASED EDGE, SQUARE CORNERS, CALIBRATED 4 GAUGED GROUT: LATICRETE *30 SAND BEIGE, UNSANDED 500 SERIES 1/16' GROUT LINE - EASED EDGE, SQUARE CORNERS, CALIBRATED 4 GAUGED ORESEI OWNERS VENDOR CONSTANTINE COMMERCIAL CARPET BID ORESEI ARMSTRONG LACROIXO 12' H. x 1/2" INK PRIMED BASE - 12' LENGTH'S COVE TOP SET, TAUPE (I151g01) RUBBER BASE, IMPERIAL TEXTURE 12' x 24' x 1/2' TILES HONED W/ EASED EDGES 1/4' MARLITE PANELING • CRY CORNER MOULDINGS. USE IIARUTE ADHESIVE NG -375 Oki N ER'S VENDOR MARLIT E MINE'R'S VENDOR BID BID M29 18 -DTM DIRECT TO METAL ACRYLIC SEMI -GLOSS CRD57 AC (ACTINIUM) 42 OZ. 12 WIDE CLEAR SILICONE. BLACK WHERE SPECIFIED BLACK NEOPRENE M35- 00/CLEAR EPDXY PENETRATING BONDI SEALER FOR CONCRETE 12' x 12' x 1/2' TILES - HONED FINISH; (2) SIDES FINISHED EACH PIECE 1"1 ar 'e? PR113~INI5i#D DARK BROhN STAINED HARDWOOD PANEL V2" TEMPERED GLASS PAINT FOR CABINETS IN 'RECOLORS AND EXISTING GLOSS SURFACES NON -SALES AREA'S - SEE PLAN STOREFRONT GLAZING SALES FL. -REFER TO FLANS : GROUT. LATK,RETE WO SAND ME1GE, INSANDED 500 SERIES 11%' m.ROUt LIE - EASED EDGE, SQUARE COQ, CAIJ RATED • GAUGED SALES FLOOR - REFER TO PLANS NON- SALES AREA'S STOREFRONT BASE GROUT - SAME AS SALES FLOOR USE MARLITE ADHESIVE *C -375 STOCKROOM 4 JANITORS SINK WAINSCOT STOREFRONT FISH SCHEDULE SHREMSHOCK ARCHITECTS, INC. 6130 S. SUNBURY ROAD SUITE 100 COLUMBUS. C101 081 614 -545 -4550 www.shrimshock.com - 0 co 0 E1 v ; 3 6 REGIST AED ' ARCHIT I GERALD S SMREMSHOCKK STATE OF WASHINGTON _CD * 2 M N - 0WZ 4).3X- M rN�.O� M , y Z W Z 0 4 2 V Z UU t W � O U O W Q.- pt,�,N '" W W22 ,460 0 n.-OZ2 erMh Ex W z ZOO - - r 0 ...=Es s z Oxiao W O a ~ W t _� 0 n i0 �ZpU V �{.1►WOVO O[OCS .- M UZ-b U. d1S. Tz Z MWrM" MO Z 2 W • � . J r REvSIoNS: A giumusimi "IL -k .W- d11 's - eras a +.Ixrts +v OrMIM . We INK" ..Y Cr DANE MOM& t c; / . COWIN Irt i IMMISEIt 0 r-- w±► � s u ()2 J , = ., 0 „ <Wpr -�++M V1 r, .n ;pac00Z Z Z UZnWW� 0 J iii =` e d _ V i•[ WWI O . M O oOY 3o , d -WW ',.n� 3oo� ,- 0Or=JSz o =acod �pGOWW� = OIZ O0a v. Z �'.� - W -. 0 no IC IX le .C W`■. EL 0 4E taJ p N Z v, 0 z � O • < 0 0 CD I- U a �W 0 � ta In 0 J I), - . *, rants FINISH AND DOOR SCHEDULES A00.2 BSS • • • • • a • i • ar • • 0 (A f) f I t.l f • A 1 4 PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98186 SCOPE: REMODEL. /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 A/E PROJECT O: 0100688 032Fb 03341/03132 PAOHLIIIIQX MtA UL THESE DRAW'NGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS ANO SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING By LIMITED STORE PLANNING, INC., 0 /9 /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC'). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY Of LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION Of THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION Of THE LSDC. ALL ORIGINALS OR REPRODUCTIONS Of THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. COPYRIGHT NOTICE; THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACLS, AND ELEMENTS OI IHE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS ANO SPECIFICATIONS MAY RESULT IN CESSATION 01 CONSTRUCTION, BUILDING SLILURL, AND /OR MONCIARY LIABILITY, ands LIMITED STORE PLANNING, INC. dlb /a STORE DESIGN & CONS V RUGGTION Three Limited Parkway • Columbus;, (.)hio 4:323 elepihonr:: G14.415./00 . Fax. 614 4 th.134 9 ttt tE):.• /www.L.St)tnC.;.1 irnitedlir cow * - OC�= ..�7 • • 1 CroE to C `' j X') - 4 ` co •-• Sn tn O fi ?-323 1 4''' ? 7C -< t om ati > 4f Rii F 1 4 /_f, 3 } o -. J '/ -- o scn A 4 p t • 4 a THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE. WA 88188 SCOPE: PCMODLL /DOWNSIZE PACKAGE: DESIGN TYPE: At MOND GENERATION: LSD&C PROJECT #: 00043/ /0 A/E PROJECT #: THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE Of THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC "). THESE DRAWINGS AND SPECifiCATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT B E DISPIAYFD IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSOC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL OE MADE WITHOUT THE WRITTEN AUTHORIIATION Of THE LSDC ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST B E RETURNED TO LSDC UPON COMPLETION Of THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. COPYRIGHI NOIICL THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 Of THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSAHON Of CONSINUCIION, NUILUINU SEICUNL, AND /OR MONETARY LIAHILITY, L._ M TED STORE PLANNING, INC. d /b /a E t -. L.) SAC xN & CONSTRUCTION 1 litoif l..iI ItF_ "lJ Park wr.3 r ()Ho 43A I t- ep IL1Tlt'. ;. i 'r. r'001..1 (14 41S. i 34:.4 nitiz • 'wwwvv I. ►ITt1�1'C�3t ter c :c�r`, r 4 t 4 8 NORM, Et (.p I I QUAL fl4 1 N L YOU OIN 1 -o 4 ' -b it LAYOUT POINT Q. 8' -3 1/2" N.R.O. F.D. 1 -0" MATCH 6" DIM 'B' EQUAL EQUAL EQUAL EQUAL f\i a\�\■ 4 00 111161 I I -0" - � ► POINT 3 e' -3 1/2" N,R.O. 2' -10" EQUAL 1 1/2" t1 ' I r U' f 1 4 U s ON t rU RI 17 1' -5 1/4' LAYOUT POINT 1/2" EQUAL (2) EQ, PIECES OF 2" 1/2" TEMP, GLASS 2 -10 2 " 2" 24' -0 13 40 - 0" LEASE LINE TO LEASE LINE (2) EQ. PIECES OF 2" 2 " 1/2' TEMP. GLASS 2 " 2 " LAYOUT POI N 2 " MATCH N fl { O N 0 01 . .L n Z an 0 8" ;'1, 3 • 9 PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 68188 SCOPE: RE MOM /DOWNSIZE DESIGN TYPE: Al MOND LSD&C PROJECT #: 000437/0 PACKAGE: GENERATION: A/E PROJECT 41: 0100688 032% 03341/03132 PROHhIITION ON,GS THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT I5 PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIIED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC "). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF tSOC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST Bf RETURNED TO MC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. CO 1A1G111 .MOIL THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1440; KNOWN AS THE ARCHITECTURAL W R WORKS COPYRIGHT PROTECTION 5 CO R T F 1 G ACT THE C OF O. PROTECTION 44 E INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION Of SPACES, AND ELEMENTS Of THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSAT'ON Of CONSINUCNON, BUILDING SEIZURE, AND /OR MONETARY LIABILITY, Limited rands L'M ►TED STORE PLANNING, NING, INC. d /b /a STORE [DESIGN & CONSTRUCTION hr ee 1. iniIt d Park; gay • t:Jc iL< {1tl Iy . O rli() 4323 leteptionk 614 115J000 Ea '4. 614 41! 7,34k..; r t tp /WW1 t ar•'T1 N \-1 . r. N sit cn 1 g oS /1 - i 1 , L 4 O!f Cf Vf 0 cn w i( r" tA 1 g N CT RV g ,c5), A W .< 3 = • O D c, , m c a i • i • a I, • • I• • .. Naa�aaN��`aaa�aaaaUaaaaaa �aaaaaaa��aa `aaaaaaa,∎:aaaaaaaaaaa :a aaasi`0V►taa`aaaaaaa�.aaa�•� h � �ili��i���► II `I�� I� �II _ 1 1 in 111:11ML� �� in B T� �. • :.aa∎a�aIa���►»•.`�I� » e' .∎�� �a»am a��a��i�ia��»>��� ta•∎∎���.1 c ••• taa"aaaaa■ 0^ tia ��s ∎aa»» IV 1 1 EQUAL_ EQUAL EQUAL EQUAL G�UA \ L ,, wit .av .ar •a% .aaaa•i •aaaa11 . - clot I I • , J c 1 I\ I \ I \ 1 I\ .1 I \ \I r \i I I�i I F '" I\ I \ \ I P • I W 14' -4" 2 , -O H aaa WIMMW CLEAR 7 1/4" 24' -0" CLEAR FIELD DETERMINE 31 -5 5/8" LEASE LINE TO LEASE LINE MATCH LINE i 2 Pi 11 91 1 h W P i ig li 2 1 8 F t 4 qi zip 0 1 114 li PI 0 r_a o 81 > -a vc AEg 2 al 1 41 0 i; 0 14 141 ill! RI l PI 1: 5S. I P g Adi 11 le i! q MI! --(), i iol i 6 la %U 4 ■ n u r Z 1 1 I a • C7 a N 1 G El 7, s 1 Fin W Fl • M o � al Z O m w N \ 14 ir I 01 5 14 OF Pi 1 14F § e c0 ii6 5,t ai 1 51 ca E gpC 1N1 0 G IF 92 R IA I 4! A' 3 Pig g ' ; i C-) L f Z In {) Vt V) 'I CM 1 1 PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 981e8 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043//0 A/E PROJECT #: 0100688 032 Fb 03341/03132 PROHIBITION ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME, REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC"). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC, NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST IF RETURNED TO LSOC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. COPYAIGfI NQT1CL THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION Of SPACES, AND LILMLNIS 01 THL DESIGN. UNDER SUCH PROTLCTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSAIiON DI CONSTRUCTION, BUILDING SLIZURL, AND /OR MONLIARY LIA91LIIY. Limited brands �.,.? M1TEO STORE PLANNING, INC. d ,!b /a STORE .,.DESIGN &. CONSTRUCT ON ihree I. i €1'IItt'd Pat t way • Columbus. Oiuo 4323G F t'It'1 i;;.;l,t 614. i:1 7 Fax: 614 11:.)1349 �tfii .. .•' L. aL)r,(: E rg It rar.ci.; cor C t v • i I • • a sr i f • • '•aIpf� •.INf" _. ►. 1=IINK, mom ►811 _ - c.■ 7 .�e �►i,r� - - - -. � : w . i? INIM "�r o `VC/. , sa� �� [idiom 11 ;a 01 P r m z •s v tro tit 14 H 3 i PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: REMOUI L /DOWNSIZE PACKAGE: DESIGN TYPE: Al MONO GENERATION: LSD&C PROJECT #: 00043//0 A/E PROJECT #: 0100688 032Fb 03341/03132 PR4HiBIT14N 4N ��; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEW ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC'). THESE DRAWINGS AND SPECifiCATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT RE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT E%CEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED RY THE LSDC. COPYRIQHI NOTICE; THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, IT U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL W WORKS COPYRIGHT PROTECTION 0 S CO RIG A T OF 1990. THE PROTECTION C O 990. H PR I E O EC 0 INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT iN CI.SSAT∎ON Of CONSTRUCTION, BUILDING SEIZURL, AND /OR MONETARY LIABILITY, I _ mitec braids L�MITE.D STORE PLANNI _:i, INC. I f I( t t. l t1Itt, J Park Y1�Iy . C; i�luTti l:. I t. k t b o i l t:." 614 t 41;')./() Fa K. (r S. -1 i 4 , 1. 1 t/ 3 ( iji. , �i/VY�J`ti [. �"lA..'fll Liu k`i11$i rii,f ; -,); . OSCIUSOStn g LA8 g M � T C n t? w 0 3 co EA v' Z E, • • • • 4 • n r 0 z z %ES. titi\A.vuuuuti EQUAL 3V - 5/8" LEASE LINE TO LEASE LINE 24 EQUAL .\■■• . w 1ii%111. q J — O w A y 4' -0" 4' -0" I I� I pK (NL1 I I r. I a D > A. MEM. B= \ \ \\ \ \ \\\\ \\\\\\ !`\ \ \\ \ \\\ \ \ \ \ \t \\ \ \ \ \ \ \ \\\ \ \\\ r .1\ \ \ \i \\ii\ \ \ \ \ \\ L \r" \\\\ \ \ \ \ ■••1\ \ \ \ \ \ \ \Ig 1M E o I I E h E I I 111 m 1 1 ,f I I I t I I I I ° 0 Zi 1 If - . �+1 —_o � I I —0 I I 0 w in I I o� 1 0 II ©0 II ;II 0II 0I Ea. EQ. Q. I I i I I I .b MATCH LINE r z 0 0 G z pgg gg r m v m F: mi F; N U T' r z z 0 cn m 4 • I . P kis fl 1 kli q 3 gk -4 fi 8 NC 8 g 2 h 11 h. IF iA iP i: FJ 1 11 P._ ; i fi et kb il 1 81 P a ; ! p g; I -4 OS g i 1 " 4 ! P 1 4 1 - i i X I V I g R I F t i 4 4 a sii j o _ -@� 5 �0 I g s i i 0 I g @ i i ! . i f: H i' 4 h 0 8 11 -.' 2 A q R AI ! I e 1 / ill i eN i' !ij _ r 13 a i 6 c% 5 i I . A i F 1 3 a A ; Ca i W I 4 4 T; 4 PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 9010E SCOPE: REMODEL /DOWNSIZE P ACKAGE: DESIGN TYPE: Al. MON G ENERATION: LSD&C PROJECT #: 000437/0 A/E PROJECT #: 0100688 032Fb 03341/03132 PROM BITIQ j Q REUSE, TNLSE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE, THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LihITED STORE DESIGN AND CONSTRUCTION {"LSDC"). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL PE MADE WITHOUT THE WRITTEN AUTHORIIATION OF THE LSOC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSOC. COPYRIG!!t 1iQTlGE: THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSAIFON UI CONSINUCIION, BUILDING SLI /UME, AND /ON MUNEIANY LIAR /CITY. limited b ran LJM[ TED STORE PLANNING, INC.;. d /b/ 5'T R I.. - I w' & GON: J HUCTIC)N I tirc. Inoted Par . Wdy Columbus. (.ft:;t.i 4323:. f eit.. ; oiii! (5 1 15. /006 • I-a... 6x14 1 i'3 7349 rittr). wvuA/.l L. u nitekiiii : km) * • O co x3 I , cm CPE 3102 g I S ea • g A sr A 3 cra . as t 4 z • 4 a NORTH I 11 lip wpm a,liNEIL ∎astarigiallatthabia.. �L ► r q.� \ ∎iM\\\\i \∎ \ ■\ \\\\\\\ \ \ \ \\\ \ \\ ■∎\∎\\\\\\\ \ \ \ \ \ \ \ \\\\\ \ \t \i \ \\ \\ \\\ \ \ \�' \. % [ 1 1E rr r 8 3. an N a z 19 1 9 1 1 I { PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSDa&C PROJECT #: 00043/70 A/E PROJECT #: 0100688 032Fb 03341/03132 PRQHIOITIQ}i ON REUSE: THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOuStY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY ( LI " MI LS O ) STORE , PLANNING, INC., 0/11/A LIMITED STORE DESIGN AND CONSTRUCTION THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. THESE DRA AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 1T U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE R ARCHIT CT R ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION Of SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSAIION 01 CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY, ted brands LIMITED STORE PLANNING, INC. `TORE DESIGN & CONSTRUCTION Throe !Aided Pa!k w 3y • CoIuo btlti, Ohto 43130 elf }) iu;)t:. 614.4 lb. ?()O Fax. b14 41,t1)1349 �t t:f.): '; ww''.[ S D imito (3r{ r cor;I 1E at 0 WM r 1 C !�7 r^ Ul iTa clo Egti g _ 3 !i o r s o' z A SF O - O O 1 1 [3 1 1 1 J t 4 z • 4 a NORTH I 11 lip wpm a,liNEIL ∎astarigiallatthabia.. �L ► r q.� \ ∎iM\\\\i \∎ \ ■\ \\\\\\\ \ \ \ \\\ \ \\ ■∎\∎\\\\\\\ \ \ \ \ \ \ \ \\\\\ \ \t \i \ \\ \\ \\\ \ \ \�' \. % [ 1 1E rr r 8 3. an N a z 19 1 9 1 1 I { PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSDa&C PROJECT #: 00043/70 A/E PROJECT #: 0100688 032Fb 03341/03132 PRQHIOITIQ}i ON REUSE: THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOuStY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY ( LI " MI LS O ) STORE , PLANNING, INC., 0/11/A LIMITED STORE DESIGN AND CONSTRUCTION THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. THESE DRA AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 1T U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE R ARCHIT CT R ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION Of SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSAIION 01 CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY, ted brands LIMITED STORE PLANNING, INC. `TORE DESIGN & CONSTRUCTION Throe !Aided Pa!k w 3y • CoIuo btlti, Ohto 43130 elf }) iu;)t:. 614.4 lb. ?()O Fax. b14 41,t1)1349 �t t:f.): '; ww''.[ S D imito (3r{ r cor;I 1E at 0 WM r 1 C !�7 r^ Ul iTa clo Egti g _ 3 !i o r s o' z A • 1 i t 11 • on r 0 a r r fA Z z 111 X „......-__ �� 0 I L__ — 1 ` li 1 a_ \ 11 % 11 1 - 1 1 1 TI � ....... I� 1 ,,, \i 46 il SI G" 1 ' .4...emf 1 1 I \! II 11 11 1 1 1 ! 1 \ 1 �l If I 1 11 1 1 1 1 1 \ 1 1 t�I I I 1 1 1 1 1 1 1 1 \ i i-- -4 � 1-i - --.J � 1-4--1-1 1- - - - - --NI l 1 1 11 1 1 1 1 1 1 1 1 1\ 1 1` I II 1 f 1 1 1 1 1 1 1' 1 11 " 1111 f1 1 1 \ �1 LLA_LJi JJ- - - --- �__ -.� -_A 1 1 \ R I \ I II I 1 1 1 1 I I I I C' 1 K11 1 1 1 1 1 1 1 1 \I I I•- -I -N1- i- ---1-1 I-1- -1-1 lc-- 11l 1 11 1 1 1 1 1 1 1 I\ 1 1t I II I 1 1 1 1 1 1 I\ 1 I L LLJL± === L \_. a ciD (iip l"1 G au 1 a Z Z 0 m 0) T w N ga gig igF gik I a i g a g ' R CC i4 4! 1 _ rg = f Vi 1 ti 8 gl .5 pi iP a ;1mi 0 a 111 IA CV 7 1 LJd '1 PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 A/E PROJECT #: 0100688 032Fb 03341/03132 PROM BITION ON REUSE THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS. OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT I5 PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DEVON AND CONSTRUCTION ("LW"). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPEC ifICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSOC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. GOPTR14tiI. NQIIM THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 L,.S.C. AS AMENDED DECEMBER 1590; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION Of SPACES, ANO ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS ANO SPECIFICATIONS MAY RESULT IN CLSSAIION Of CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY, Limited brand LIMITED STORE PLANNING, INC, d /b /a STORE DESIGN & C(_ STRUC1ION i hrefa I_ rii tE'd Park Nay • Calun w.,. Oho 43^ ., 1 & i t ptionI 6i 4 . 4 ` t : . /U;) 0 • I` a x : 614 4 ) ./ .,9 hi [t): wvvvvv i °it_1�IC; I i►t1 r't iil r r.(i:; con: I 1.0 • u lei n W 0 ' O C3 � 3 � O 0 cn Ili • • • • NOT p99 = III...uuuae1 •*SUS ...uuu..u ==1,,,i,LL I ' 1 4) immin r:;77sss: - - -- - - I - =4 - r, - DREAM LEAR AMER HANGER MANAGEMENT 1—L. � \ \ \ \ \ M \ \ R \ \ i � ► � � : � � � � 7 II t i� \ � s � . � � � \ � a \ \ E \ \ \ ! \ \ \ \ \ i \ i \ i \\ \ i i ` � \ � � � 1 \ \ \ii \ii iii ii \iii \�liiii \ \\ \' t i 24, _01► 40' -0" LEASE LINE TO LEASE LINE MATCH LINE ; 1 • m FYI g I/!f n 'I 31 PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: REMODEL /DOWNSIZE 'PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043/70 A/E PROJECT #: 0100688 032Fb 03341/03132 PNQHIBIIIDN ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIIED IN WRITING BY LIMITED STORE PUNNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC "). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT Br DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIIATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION or THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. TH R SE D RAW DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL S CO PYR HT WORKS T ACT PROTECTION D IG PR PROTECTION A F i T H INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM. ARRANGEMENT AND ANDCOMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE Of THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION of CONSTRUCTION, BUILDING SL1tURL, AND /OR MONETARY LIAHILIIY, limited brands LIMITED TORE PLANNING, INC. d /b /a. STORE DESIGN & CONSTRUCTION hree I..ir4;itF d Parkr►oy (1)too , 132;3 1 t_ ie i I= 614.41::).10D0 - 614.41.5 / 43 ht . ) vvvv,P; ... `.� ..1[t f.(. ;F21i C'C I ar(V ;• or 06 tit DI CA : i�c . TOS g A v n OT v 0 CA 3 - • 4 4 • • PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE. WA 98188 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSDC PROJECT �: 00043770 AjE PROJECT #: 0100688 432Fb 03341/03132 PROHIBITION ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE Oft AT A LATER TIME. REUSE Of THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC"). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPIAYEO IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. CQPYRIGH1 $QIICE; THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION 01 CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY. limited b LIMITED STORE PLANNING, INC. d /b /a STORE DESIGN & CONSTRUCTION I hree Limited Parkway • Cuki - sus. Ohm 43230 1 ek!p ELI I: b 4.415.7 .000 • Fax: 611 , 115 7349 ETt ip ' "V5r'11VW. ` 1.. 11G CO L.ir Ito E: F"ar ; �Y1 NORTH oQ 2% 0 „ Z - THE — — — — r LEAR DREAM f r EAMER HANGER MANAGEMENT „MEL kJ AL . III. r u\I \ � \ (Do Q 1 tl i,ll r ; j i _ `\ ; 1 1, \ X1 1 I 1 L�w, I I r,`.o. 1 1 1 1 1 I\ i 1 I I ' I .' _ - R L - - \ I<I - 1 1 T1 - - I r = = =r - - - ly i 1 I I \ \ I II I 111 1 I I I I \I I I I I II I I I I `\ I I I KII I I I I I I I I \I k I- -1-N1-1- - 1 - - 1 1 - 1 - - - - - 1 ■1 1 II I 1 11 1 11 I\ I 1 111 I I 11 11 I \ 1 f I L1_J 7LJ J - 'I__ \ A 31 -5 5/8” LEASE LINE TO LEASE LINE 24' -0" > > > > > > tJ1 1n N N W N A 4' -11 5/8" LL TO LL MATCH LINE t • • • • • s • s 0 • 0 N 3 illMe • • • • • i . . I 4 4 4 4 4 . 4 . . I • • • i . . . • . W a i f * • . r � • °,ier • • • I • i • • • E�. so iti i6 U W IC:1 1 \\S3 0 r � -v . f rl c: ,s r 1 rn ao rn co 0 ID N CO N ^ z �O J nris 46 11 0 Z O C Cl) m v 0 m r11 < -1 >rn ga : 21 N ;1mi I 4 t PROJECT INFORMATION: THE LIMITED SOUTHCENTER 033 SOUTHCENTER MALL SEATTLE, WA 961e8 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 Aft PROJECT #: 0100688 032Fb 03341/03132 PROHIBITION ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE, THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS. OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNINO, INC., 0 /B /A LIMITED STORE DESIGN AND CONSTRUCTION ("LSDC THESE DRAWINGS AND SPECITICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. THESE DRA GS A ND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK" UNDER SEC. 102 Of THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION. UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION 01 CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY. I i m ited brands LIMITED STORE PLANNING. INC. /b /a. STORE DESIGN & CONSTFWCTION l hr I.ifIItE tl Pak way • Columbus, Ohio 4 Telephone. 614.415./000 • I-n k' 614. 415./349 1111 www.t. `at..:)t, {::I4mitecibt and oun v' q Q s ▪ 01 f'? tn O1 = IA ;� C 1 :° 8 t?r ot r t Z2 A W 4 =. O 0 1 3 cot O o r n a N, ,\ , , 1 \ \ ‘. \ / \ / \ / \ , v M X 4 / / , r. \ \ \ t / /, \ \ r 1\ / e \ ~ / \ r / , \\ \\ 4, t • • • • • s • s 0 • 0 N 3 illMe • • • • • i . . I 4 4 4 4 4 . 4 . . I • • • i . . . • . W a i f * • . r � • °,ier • • • I • i • • • E�. so iti i6 U W IC:1 1 \\S3 0 r � -v . f rl c: ,s r 1 rn ao rn co 0 ID N CO N ^ z �O J nris 46 11 0 Z O C Cl) m v 0 m r11 < -1 >rn ga : 21 N ;1mi I 4 t PROJECT INFORMATION: THE LIMITED SOUTHCENTER 033 SOUTHCENTER MALL SEATTLE, WA 961e8 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 Aft PROJECT #: 0100688 032Fb 03341/03132 PROHIBITION ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE, THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS. OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNINO, INC., 0 /B /A LIMITED STORE DESIGN AND CONSTRUCTION ("LSDC THESE DRAWINGS AND SPECITICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. THESE DRA GS A ND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK" UNDER SEC. 102 Of THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION. UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION 01 CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY. I i m ited brands LIMITED STORE PLANNING. INC. /b /a. STORE DESIGN & CONSTFWCTION l hr I.ifIItE tl Pak way • Columbus, Ohio 4 Telephone. 614.415./000 • I-n k' 614. 415./349 1111 www.t. `at..:)t, {::I4mitecibt and oun v' q Q s ▪ 01 f'? tn O1 = IA ;� C 1 :° 8 t?r ot r t Z2 A W 4 =. O 0 1 3 cot O o r n a N, \ / \ / \ / \ , v M X t • • • • • s • s 0 • 0 N 3 illMe • • • • • i . . I 4 4 4 4 4 . 4 . . I • • • i . . . • . W a i f * • . r � • °,ier • • • I • i • • • E�. so iti i6 U W IC:1 1 \\S3 0 r � -v . f rl c: ,s r 1 rn ao rn co 0 ID N CO N ^ z �O J nris 46 11 0 Z O C Cl) m v 0 m r11 < -1 >rn ga : 21 N ;1mi I 4 t PROJECT INFORMATION: THE LIMITED SOUTHCENTER 033 SOUTHCENTER MALL SEATTLE, WA 961e8 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 Aft PROJECT #: 0100688 032Fb 03341/03132 PROHIBITION ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE, THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS. OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNINO, INC., 0 /B /A LIMITED STORE DESIGN AND CONSTRUCTION ("LSDC THESE DRAWINGS AND SPECITICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. THESE DRA GS A ND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK" UNDER SEC. 102 Of THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION. UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION 01 CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY. I i m ited brands LIMITED STORE PLANNING. INC. /b /a. STORE DESIGN & CONSTFWCTION l hr I.ifIItE tl Pak way • Columbus, Ohio 4 Telephone. 614.415./000 • I-n k' 614. 415./349 1111 www.t. `at..:)t, {::I4mitecibt and oun v' q Q s ▪ 01 f'? tn O1 = IA ;� C 1 :° 8 t?r ot r t Z2 A W 4 =. O 0 1 3 cot O o r n -� .I I - , • • . • . • • . •• , 1 1 I • ...... . .1 I I • .. • . . 1 • .1 L J r I • • • • • . • ` i ( /∎■ /,/ ∎` I! \ 1 ■ ) i ~%`■ // 1 1 I I s• 1•••■ • 1 I If f • • • a 4 m Z 0 C rn v z 0 C rn v L i ■ II 0 to T • C l n. I /1 r , T1 LM 9 i 4 PROJECT INFORMATION: THE LIMITED SOUTHCENTER 433 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: Rt.MODLL /DOWNSIZE PACKAGE: DESIGN TYPE: Al MOND GENERATION: LSDd(C PROJECT #: 00043/70 A/E PROJECT #: 0100688 032Fb 03341 /031 32 PROHIBITION ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE, THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS. OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIIED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC"). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC COPYRIGHT HOIIGE; THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 12 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990, THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSA1IUN 01 CONSTNUCFIUN, BUILDING SEIZURE, AND /OR MONLIARY LIABILITY. limited b ands LIMITE(�D STORE PLANNING, INC_ d/b/a STORE 1)17--)1CiN & CONSTRUCTION i hrei: 1.IwIted Parkway . Columbus. Ohio =1323u t r lr pt one 6t , 415. /t. }:.)ti Fax. 614 41b /340 11t1)). "vvvvw,t rY'ttr COrll .I I - , • • . • . • • . •• , 1 1 I • ...... . .1 I I • .. • . . 1 • .1 L J If f • • • a 4 m Z 0 C rn v z 0 C rn v L i ■ II 0 to T • C l n. I /1 r , T1 LM 9 i 4 PROJECT INFORMATION: THE LIMITED SOUTHCENTER 433 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: Rt.MODLL /DOWNSIZE PACKAGE: DESIGN TYPE: Al MOND GENERATION: LSDd(C PROJECT #: 00043/70 A/E PROJECT #: 0100688 032Fb 03341 /031 32 PROHIBITION ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE, THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS. OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIIED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC"). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC COPYRIGHT HOIIGE; THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 12 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990, THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSA1IUN 01 CONSTNUCFIUN, BUILDING SEIZURE, AND /OR MONLIARY LIABILITY. limited b ands LIMITE(�D STORE PLANNING, INC_ d/b/a STORE 1)17--)1CiN & CONSTRUCTION i hrei: 1.IwIted Parkway . Columbus. Ohio =1323u t r lr pt one 6t , 415. /t. }:.)ti Fax. 614 41b /340 11t1)). "vvvvw,t rY'ttr COrll r I • • • • • . • . • 7 1 1 I I s• 1•••■ • 1 I L_ 1 If f • • • a 4 m Z 0 C rn v z 0 C rn v L i ■ II 0 to T • C l n. I /1 r , T1 LM 9 i 4 PROJECT INFORMATION: THE LIMITED SOUTHCENTER 433 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: Rt.MODLL /DOWNSIZE PACKAGE: DESIGN TYPE: Al MOND GENERATION: LSDd(C PROJECT #: 00043/70 A/E PROJECT #: 0100688 032Fb 03341 /031 32 PROHIBITION ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE, THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS. OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIIED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC"). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC COPYRIGHT HOIIGE; THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 12 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990, THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSA1IUN 01 CONSTNUCFIUN, BUILDING SEIZURE, AND /OR MONLIARY LIABILITY. limited b ands LIMITE(�D STORE PLANNING, INC_ d/b/a STORE 1)17--)1CiN & CONSTRUCTION i hrei: 1.IwIted Parkway . Columbus. Ohio =1323u t r lr pt one 6t , 415. /t. }:.)ti Fax. 614 41b /340 11t1)). "vvvvw,t rY'ttr COrll • • L, al 16 r A �J! r If ►rM=I1 I f ■ / ►O1 1 ,..... 4 ►7 •■, 1 0 .11■ N 01 .,.. 4 ► �I /.1 ►p1 ► ■- 1 .. I i limim ni 1�1 ► �i ) I ►�I /711■111, 1 ►7111■ ►711■1■I ►� 1 VIIMIIMOIN ►�I ► �1 /�� 1 ►�1 ►��I ►� 1 . �1 1�I ►,�1 /�I /1 , •■�I / =1 ► .81■ 41 .■4 ► 7.1■ 1 ► 7■ 41 1 ■I pi..■. i mmom•F I ► 71■... I ► =1 0...=. 1 144F 'r ,. ti Z n 1 qui PA N _A Ao lg ;1i q a t � • z O C rn v C) r C z 0 . C Cl rn v 11 Z O C m v CO C) r m co C) n D O CO C -, CA � 9 • T• • 4 W PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 90108 SCOPE: RLMODEL/DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT O: 00043770 A/E PROJECT #: 0100688 032Fb 03341/03132 PROHIBITIOI4_QN REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE Of THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., D/B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC "). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT lir DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES. WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION Of SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION. UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSAI UI CONSINUCIION, BUILUtNG SEIZURE, AND /OR MONLIARY LIABILITY, Limited brands LIMITED STORE PLANNING, INC. d /b /a STORE DESIGN .. CONSTRUCTION ION F Irti Limited Parkway Cu urrtbus. Ohio 4323 eiepho e: 61 100C) • F =ax. 614 415 7349 http::' wrr� Stj, (., L ImItI +cik3r ar- fia,.con, 4E CPI 0 c i co, ( � c�o+� 3 g z ( W 3 of l r f (,) Q z n • 2" TYP, ;CAN VARY) 1/4" GAP PRE - FINISHED DARK in BROWN STAINED HARDWOOD GLAZING MEMBER. PROVIDED BY OWNER, INSTALLED BY G.G. N 5/8" TYPE 'X' GYPSUM BOARD ON MISC. METAL STUDS • 16" O.C. PAINT P -10 x#200 BEAD AND CAULK 1"l0.4 x I" DP. METAL GLAZING CHANNEL BELOW. 1/2" TEMPERED GLASS G - I I FACE OF BASE BELOW B -4 I MT -2 I 2" x 7" NHITE BREAK METAL "L" SHAPED ANGLE REVEAL. G.G. TO SUPPLY MISCELLANEOUS F.R.T. BLOCKING BEHIND AS REQUIRED. G.G. TO HEM METAL EDGE. LEASE LINE TYPICAL NEUTRAL PIER LOCATION; REFER TO DETAILS FOR STORE SPECIFIC CONDITION. END MULLION DETAIL HEAD SECTION BASE SECTION z 1 r -O " 01DA082MO 2 7/8" TYPICAL MALL BULKHEAD AND METAL REVEAL AS REQUIRED; REFER TO SPECIFIC STOREFRONT SECTIONS MT -2 i . 2 "x2" "L" SHAPED WHITE BREAK METAL ANGLE REVEAL, SUPPLIED AND INSTALLED BY G.C. HEM BREAK METAL SO THERE 15 NO RAW EDGE. MISCELLANEOUS F.R_T WOOD BLOCKING AS REQU I RED. PRE- FINISHED DARK BROWN STAINED HARDWOOD GLAZING MEMBER. PROVIDED BY OWNER, INSTALLED BY G.C. LEASE LINE * FACE OF HARDWOOD GLAZING MEMBERS COINCIDE (TYPICAL) BREAK METAL CLAD OVER 5/8" GYPSUM BOARD ON 2 1/2" METAL FRAMING 40 16" O.C. 6 " =1"-O' 01SAO82L0 FI L1115:11ial M L FC - OVER (2) LAYERS OF 3/4" F.R.T. PLYWOOD SUS FLOOR ON 3 5/8" (18 GAUGE) METAL FRAMING AT 4' o.c. PRE - FINISHED/PRE - FABR ICATED :3/4' MDF PANEL et/ ALMOND FINtSi.1_ PROVIDED BY OYWNER t INSTALLED BY G _C 3/4" x 2" PRE - FINISHED DARK BROWN STAINED HARDWOOD GLAZING MEMBER. PROVIDED BY OWNER, INSTALLED BY G.C. I" W x 1" DP. METAL GLAZING CHANNEL BELOW 1" W x I" DP. METAL GLAZING CHANNEL BELOW. CENTERLINE 1/2" TEMPERED GLASS PRE - FINISHED DARK BROWN STAINED 1- IARDWOOD GLAZING MEMBER. PROVIDED BY OWNER, INSTALLED BY G.G. FACE OF SIGN BOX ABOVE 08 LEASELINE AND FACE OF HARDWOOD GLAZING MEMBERS COINCIDE FACE OF 5-4 Id BASE BELOW SE _____[71_____ 1 /2" )0» 1/4" GAP 4 if) MULLION DETAIL I FC -c1 II OVER (2) LAYERS OF 3/4" F.R.T. PLYWOOD SUBFLOOR ON 3 5/8" (18 GA) MTL FRAMING t? 16" O.G. 3 1/2" iV LEASELINE AND FACE OF HARDWOOD GLAZING MEMBERS COINCIDE. 1" W x 1" DP METAL GLAZING CHANNEL WITH BLACK NEOPRENE GLAZING GASKETS 5-5 II B -4 PRE- FINISHED DARK BROWN STAINED HARDWOOD GLAZING MEMBER. PROVIDED BY OWNER, INSTALLED BY G.C. MISCELLANEOUS F.R.T. BLOCKING AS REQUIRED. 1/2" STONE BASE OVER 3/4' F.R.T. PLYWOOD ON 6' (18 GA) METAL STUDS Q W O.C. SILL SECTION @ PLATFORM (EXT.) SILL SECTION CP PLATFORM MT. 6 1._ 1 ' 0 " 01DA082JO r=r-o" OISAO82HO I =C - 0 OVER (2) LAYERS OF 3/4' F _R T PLYINCOD SUBFLOOR ON 3 5/8' (18 GA) MTL FRAMING p W O.C. PRE - FINISHED DARK BROWN STA +NED 16+AR'Dr4COO 'R '�'"' PROV DED BY OrWER NvSTA.a.ED B" G_C. G,c,/+ •rERS. NK F N:514 NIA : L . EADS • 'r c C - 3 i 4. p 4�i J H G 1/4" GAP I /4" GAP ' W x 1" DP. METAL GLAZING CHANNEL BELOW . 1/2" TEMPERED GLASS G -I FACE OF LEASE LINE PRE - FINISHED DARK BROWN STAINED HARDWOOD GLAZING MEMBER. PROVIDED BY OWNER, INSTALLED BY G.G. I BASE BELOW. MULLION DETAIL 6 "a1• O" OIDA082F0 SUSPENDED GYPSUM BOARD CE ILING ENTRY GLAZING CHANNEL • HEAD MT - I FILLER PIECE TO MATCH SIGN BOX. FIELD FABRICATED BY G.C. ON 5/8" GYPSUM BOARD MT -1 ILLUMINATED SIGN BOX ENTRY HEAD DETAIL SILL SECTION 0 PLATFORM MIT. 6" T-O" 01DA082E0 PRE -FIN - ED/ PRE -FABR TED 1 1/2" M .D.F. PANEL DOOR AL3" ON I F I SN . HARDWARE DED BY OWNER AND INST BY G.C. OVER (2) LABS OF 3/4' F -R_T_ PLTOtOD \\ S uBFLOOR ON 3 5/6' 06 GA\ r'TTL FRAMING • 1G' O . C_ 8— ; • 11. '4 1 c1 F E D O 1/4" GAP SE 2" 1/4" GAP in PRE - FINISHED/ PRE - FABRICATED 3/4" MDF PANELS W/ ALMOND FINISH PROVIDED BY OWNER INSTALLED BY G.C. ON F.R.T. WOOD FRAMING AS 5HOWN. FACE OF BASE BELOW B -4 I 1" IN x I" DP. METAL GLAZING C1dANNEL BELOW. I /2' TEMPERED GLASS G -1 PRE - FINISHED DARK BROWN STAINED HARDWOOD GLAZING MEMBER. PROVIDED BY OWNER, INSTALLED BY G.C. FACE OF [ 8 -4 11 BASE BELOW LEASELINE AND FACE OF HARDWOOD GLAZING MEMBERS COINCI DE MULLION DETAIL OVER (2) LAYERS OF 3/4" F.R.T. PLYWOOD SUB FLOOR ON 3 5/8" (18 GAUGE) METAL FRAMING AT 16' O.C. CENTERLINE 1/2" TEMPERED GLASS 1" W X 1" DP METAL GLAZING CHANNEL WITN BLACK NEOPRENE GLAZING GASKETS [ S -5 PRE - FINISHED DARK BROWN STAINED HARDWOOD GLAZING MEMBER. PROVIDED BY OWNER, INSTALLED BY G.C. B -4 I/2" STONE BASE OVER 3/4' F.R.T. PLYWOOD ON 18 GAUGE METAL STUDS AT 16" O.C. I /2" p03 -42,4.7 SILL SECTION B —i II/2' STONE BASE 0401166 ` rrEiR .o - r • Q I 1/2' ,.3 "WO T or, 4i- Co ` I ._._�� —46 STOLE BASE CORNER DETAIL 6• =1' -0" 01DA082Co r :r-o" O1SAO82B0 B PI E A . r3 SHREIASHOCK ARCHITECTS, INC. 6130 S. SUINIURY ROAD COLUMBUS mil. 430.1 SUITE 10 ` ,�; 614- 545 -4590 www.shrsmshock.com co co ro 0 0 O J 7:3 DATE ISSUE& DESIGNED Iff: OAMNM1 SY: CHECKED If: CI W u W I W; Z Za la X J in— a) 2 I i H , rrux 1 1111 ....r11111 +. _ • sib REVISIONS: r-, - ofIZEP * � - STANDARD STOREFRONT DETAILS A08.2 z 0 :: ! - � � 'S z � - Q,ca.v z � $ plr ck al ""• ... x p .,r -Z:do t 3OtK ag WO ^s 'Wz U K V O i N o u+ r( h . lp -w mr3 �- W Q 7 W V 3 h g z z Zu24 ;° U W .. -Oi .-i n tVVr`x►- V N NN � 2Wa ©EE!:::4 JWON r Z w od z7; O � 4�W ff u r = u,.., Eooc N L- M M 0 M M 0 0 o Z n � Q 0 0 Ds rJ 76 33 JED 85S • • • • • NOT USED SCALE w 5/8" GYPSUM BOARD BOARD CEILING ON METAL FRAMING; G.C. TO PROVIDE IN -WALL BLOCKING FOR TRACK SUPPORT. /- 1" I .D. 0/2" 3/16" RECEIVER TRACK G.C. TO PROVIDE CONTINUOS METAL BLOCKING • MARKETING RAIL AS SHOWN. ATTACH WITH TOGGLE BOLT RATED TO 75 POUNDS • W O.C. MAXIMUM STOREFRONT SOFFIT DISPLAY RAIL, CONTINUOUS IP STOREFRONT. REFER TO STOREFRONT SECTIONS PRIMED WHITE (THE LIMITED) m r n 5/16" I/8" FIELD VERIFY MATH CONSTRUCTION MANAGER. I1 /16" 03/8" 5/16" HANGER DETAIL - FRONT ELEVATION WHITE HAMMERTONE FINISH (THE LIMITED) STOREFRONT SOFFIT DISPLAY HANGER; COORDINATE INSTALLATION WITH CONSTRUCTION MANAGER VARIES (lb" MN. TO 28" MAX.) I — L 18" MIN ROD DETAIL --N NNNN,„ STOREFRONT SOFFIT DISPLAY RAIL, CONTINUOUS • STOREFRONT. REFER TO STOREFRONT SECTIONS STOREFRONT SOFFIT DISPLAY 11/16" ROD; COORDINATE 1 / 8 " INSTALLATION WITH 1 /2" CONSTRUCTION MANAGER WHITE HAMMERTONE FINISH (THE LIMITED) NEXT SMALLEST ROD DIAMETER, INSURING TIGHT FIT t EASE OF OPERATION I/2' 0 ROD 03/8" — I FO332-tb 1/8" v aD N G.C. TO PROVIDE 5/8" GYPSUM BOARD TO THE BACK SIDE OF MALL BULKHEAD TIGHT TO DECK ABOVE THE ENTIRE LENGTH OF STOREFRONT I F NOT EXISTING. EXISTING MALL STRUCTURAL BEAM 2x2x0' -6" LONG 14 GA FRAMING CLIP, TYP EA END. CONNECT TO STUD W/ (3) -u12 SCREWS. CONNECT TO BEAM W/ (2) -412 SCREWS OR (2)- 0.145" DIA POWDER ACTUATED FASTENERS (HI LTI X -DNI OR EQUAL) 11' -6" A.F.F. PREFINISHED ALMOND PANEL BEYOND. CONTRACTOR TO VERIFY/ FIELD MEASURE EXIST!NG STEEL BEAM SIZES, LOCATIONS AND SPANS AND FORWARD TO ARCI-I ITECT FOR REVIEW AND WRITTEN APPROVAL. I ,. PIIG •"O "1,► Er $+ hIG EXISTING MALL LIGHT COVE TO REMAIN. G.G. TO PROTECT DURING CONSTRUCTION NEWLY RE- MODELED MALL BULKHEAD. G.C. TO COORDINATE WORK kV LANDLORD. G.G. TO PAINT p - II 3 5/8" x i8 GA. METAL STUDS to 16" O.C. 5/8" PAINT T PSUM BOARD; PORTION OF EXISTING MALL BULKHEAD TO BE REMOVED (SHOWN DASHED) . REFER TO STOREFRONT ELEVATION 4 CONSTRUCTION PLAN FOR EXTENTS. 14' -0" A.F.F. (V.I.F.) MALL COVE 13' -O" A.F.F. MALL BULKHEAD (REWORKED) NT -2 (2" x 7/8' DEEP 'L" SHAPED WHITE BREAK METAL ANGLE PROVIDED 4 INSTALLED BY G.C. OVER F.R.T. WOOD BLOCKING (AS REQUIRED) (2) 1 5/8' x 12" x 16 GA. JOISTS REFER TO DETAIL J/AO8.5 RECESSED CAN LIGHT - REFER TO REFLECTED LIGHTING PLAN q' -O' A.F.F PRE FINISHED DARK BROWN STAINED HAROw+ :,D GLAZING MEMBER BEYOND. TOP CORNER PATCH PIVOT BEYOND CENTERLINE OF S*GN BAND SUPPORT (BEYOND) REFER TO DETAIL */A045_4 G .C. SMALL OE PI1120D046 A F1.1014 smarm imuumserN24 arrowsm InALL Fix airs 404) 'MAIO* FLOORING 4 3/4" 1 1/8" 4 3/4" G.C. TO PROVIDE 5/8" GYPSUM BOARD TO THE BACK SIDE OF MALL BULKHEAD TIGHT TO DECK ABOVE THE ENTIRE LENGTH OF STOREFRONT IF NOT EXISTING. EXISTING MALL STRUCTURAL BEAM 2x2x0' - LONG 14 GA FRAMING CLIP, TYP EA END. CONNECT TO STUD W/ (3) - u12 SCREWS. CONNECT TO BEAM W/ (2) -u12 SCREWS OR (2)- 0.145" DIA POWDER ACTUATED FASTENERS (WI LTI X - DNI OR EQUAL) 1I' -6" A.F.F. 5/8" SUSPENDED GYPSUM BOARD CEILING; PAINT I P -12 CONTRACTOR TO VERIFY/ FIELD MEASURE EXISTING STEEL BEAM SIZES, LOCATIONS AND SPANS AND FORWARD TO ARCI- IITECT FOR REVIEW AND WRITTEN APPROVAL. ' -5 7/8" PORTION OF EXISTING MALL BULKHEAD TO BE REMOVED (SHOWN DASHED) . REFER TO STOREFRONT ELEVATION 4 CONSTRUCTION PLAN FOR EXTENTS. 14' -O" A.F_F. (V.I.F.) EXISTING MALL LIGHT COVE TO REMAIN. G.C. TO PROTECT DURING CONSTRUCTION NEWLY RE- MODELED MALL BULKHEAD. G.C. TO COORDINATE WORK W/ LANDLORD. G.C. TO PAINT p -1O I 3 5/8' x 18 GA. METAL STUDS 16" O.C. MALL COVE 13' -6" A.F.F. 13' -0" A.F.F_ MALL BULKI -IEAD (REWORKED) C . . BE RESPCNOSLE POR PIR OV1 OPNG A Pri..08b4 ?r*01071+ TRANSITICI1 >DET>NEEN PULL FLOORING AIND TENANT FLOORING TOREFRONT SECTION ENTRY DOORS STOREFRONT MARKETING RAIL DETAILS Mile El STOREFRONT SECTION DISPLAY PLATFORM FULL SHREUSHOCK ARCHITECTS, INC. 6130 S. SUN BURY ROAD SUITE 100 ..: ,...,�..a, . . mimeo 01 43061 614- 545 -4350 www.shr.m=hock.com !!!: 40 OXt; ""OWdZO Z W O W Z = Z nj co co r O 6923 REGISTERED ARCHITECT GERALD S. SHREMSPIOC STATE OF WASHINGTON DATE DESIGNED BY: DRAVIN DV: GAD BY: C ) 1 a..,■a °N" � ws / 41111100ES WPM. 1 .1t R SIONS: 0 c: n X. ;; • O U J [ W Z ,• STOREFRONT SECTIONS & DETAILS A08.3 z J o� N .../ Op'.' R ! O :::;:: 2 0=-0 Wan ~1J a it Z 7= j Z _O J �0 3 ZOU U � Or- U Z a 2 7 a J W z O d W iiiiii ipvi 006C.7..3.5?! 006C.7..3.5?! z !!!!!;:i! .r n ar n • * _ U ONW 4 L'H # �O (7Q W SZ � L- ti d W K NOrU �W r :006;11:13!:'7..: I�..�``JW�- .n N � re) 0 0 M 0 , / ° C SF liSS • w • • a p 4 r z Q "Ti m M m r z m digs Email in 4 rn m N 3/411 411 3 3/4" 5 -0 t /2" r cn to 2 -0" 01:00= _ '�pp3NV -4 1 zrn too] D z Drn grn 0p 2 ,. czm t� m —' Z 70 <- ��+'D -4 �AZx - 70Mtrn?I NQ 3�mu+ rmr i I z� _ az D O pani D � � Dm 9 --ii --,10'.."" . gil: 70 _ Zm ro o u r � n r Mr> TT1 D rn 0 7 40 ao7'� , DNoo r -4 <.. EL { D 5 rc �tp pop P ppN z w 70 P gz R ... n3 v m mf 70 (li M �3 - n - N m p -4 D te m n R z m A mc 3 A Nr D r c zm rn -4 rw m ri O °; > r r -4 CS M W m tai Ar, 3 v - 4 z m rn r tor rnz r m 3 -4r n m rn o � co :ith y rn in = d 4 I, ts I PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSDC PROJECT #: 00043710 A/E PROJECT #: 0100688 032Fb 03341/03132 PROHIBITION ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., 0 /11/A LIMITED STORE DESIGN AND CONSTRUCTION ("LSDC"). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY WANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC, NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE UNLESS OTHERWISE AGREED BY THE LSDC. CSIPTIEdil MIME; THESE DRAWINGS AND SPECIFICATIONS ARt COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 Of THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSAUUUN UI CONSTRUCTION, BUILDING SEIZURE, AND /OR MONLTARY LIABILITY. Limited brands LfMsTE D STORE PLANNING, INC. / d b/a TORE DESIGN ex CONSTRUCTION I hree Limited Parkway C: aitunbus, Oruo 43230 T t? tElAio e: 614.E 15.7000 • Fax: 614.415.7343 r►tt�.�. ',`www.k._ f.:)r�t. L imitedBrard ;.e:orn fri tr • 1,031g A vtt I MILL FINISH GRILLE GUI SUPPLIED AND INSTALLE OWNER GRILLE SU SUPPLIE OWNER ORT POST AND INSTALLED BY ALL MOUNTING BRACKETS FRONT SIDE OF POST TOWARD MALL) CONCEAL GROOVE AND INTAIN INDICATED DISTANCE FACE OF STOREFRONT MATERIAL TO END OF GUIDE ILLE GUIDE MATERIAL F FINI GRILL ROLL -UP STOREFRONT FI GRILLE GUIDE & SUPPORT POST DTL. C8x11.5 WELDED TO GRILL SUPPORT POST "x3 "x3/8" GRILLE PPORT POST BY SECURE 4 STRU ABOVE GRILLE FRAMING DETAIL - SECTION GRILLE FRAMING DETAIL -PLAN N.T.S. 1 1/2" =T-0" M L (2) -1 5/8" x 12" x 16 GA. JOIST. ATTACH TO SIGN POST SUPPORTS AS SHOWN. (SEE DET A/A08.4 FOR SIGN POST LOCATIONS) . 2" W. x I -0" LG. x lb GA. PLATE W/(6) -*1O SCREWS (TYPICAL BOTH SIDES) 18 GA. TRACK BUILT -UP SIGN SUPPORT COLUMN #12 SCREWS IP 12 O.G. EA SIDE 1 5/8 "x3 5/8 "x14 GA STUD 12 "x3 5/8 "x14 GA DEEP LEG TRACK SEE DET A/A08.4 FOR FULL HEIGHT WOOD BLOCKING EA SIDE 18 GA TRACK W/(2) - #12 SCREWS TI-IRU EA VERT LEG (2)- 3/16" • POWER ACTUATED FASTENERS W/ 1" MIN. EMBEDMENT SIGN SUPPORT COLUMN DETAIL STOREFRONT SECTION ThRU DISPLAY 1 1/2 " =1' -0" • J I G—• ENTRy04Ay MIN 1' -0' TILE 1 TILE 1' — O" TILE /— 3 5/8" (18 GA) METAL STUDS • 16" O.C. - SECURE TO STRUCTURE ABOVE (NOT TO DECK). 5/8" TYPE "X" GYP. BD. ON METAL FRAMING; PAINT I P -10 i 11' -i1" A.F.F. I I/2' 1O' -11" A.F.F. 2' x 3/4" PRE - FINISHED DARK BROWN STAINED HARDWOOD MEMBER SF -3 if PRE - FINISHED/ PRE- FABRICATED 3/4' 111 .D_F. PANELS (INSIDE DISPLAY ONLY) IPRf.. V I DED BY COsNER, INSTALLED BY G_C. ('TYP. ) S iG N BAND SUPPORT POST _ r -2' AF TOP OF j a F F Fl1w5�+ FLOOR Mita El 3 5/8" METAL CHANNEL (TYP. ) F.R.T. BLOCKING AS REQUIRED 5/8" TYPE 'X' GYPSUM BOARD CEILING. 1" W x 1 1/2" DP METAL GLAZING CHANNEL. EDGE BEAD (BOTH SI DES) 1/2" TEMP. GLASS G -1 HEAD DETAIL 6 "a1" -0" F -3267 3 3/4" T 4" 2 7/8" 1" W x 1 1/2" DP METAL GLAZING CHANNEL; G.C. TO TUCK MT -1 BREAK METAL. INSIDE GLAZING CHANNEL. EDGE BEAD (SALES SIDE ONLY) HEAD DETAIL G.C. TO PROVIDE 5/8" GYPSUM BOARD TO THE BACK SIDE OF MALL BULKHEAD TIGHT TO DECK ABOVE THE ENTIRE LENGTH OF STOREFRONT IF NOT EXISTING. EXISTING MALL STRUCTURAL BEAM CONNECT TRACK TO BEAM W/ (2) -112 SCREWS OR (2)- 0.145" DIA POWDER ACTUATED FASTENERS (I-II LTI X - DNI OR EQUAL) AT EACH VERT STUD. CONNECT VERT 5T U D TO TRACK WITN #12 SCREW EA FLANGE OF EA STUD. 2x2x0' -6 LONG 14 GA FRAMING CLIP, TYP EA END. CONNECT TO STUD W/ (3) -*t12 SCREWS. CONNECT TO BEAM W/ (2) - #12 SCREWS OR (2)- 0.145' DIA POWDER ACTUATED FASTENERS (H1LTI X -DNI OR EQUAL) 11' -6" A.F.F. 5/8" SUSPENDED GYPSUM BOARD CEILING PAINT P -12 5/8" TYPE 'X' GYPSUM BOARD OVER 3 5/8" METAL FRAMING AT 16" O.C.; PAINT 5/8' GYPSUM BOARD CEILING ON 3 5/8" METAL FRAMING; PAINT P -10 CONTRACTOR TO VERIFY/ FIELD MEASURE EXISTING STEEL BEAM SIZES, LOCATIONS AND SPANS AND FORWARD TO ARCHITECT FOR REVIEW AND WRITTEN APPROVAL. F.R.T. WOOD FRAMING SV¢F PRE - FINISHED/ PRE - FABRICATED REMOVABLE PICTURE FRAME w/ BACK PANEL. G.C. TO INSTALL OWNER-SUPPLIED 1/4" THICK MAGNETIC BAGGER PANEL. OWNER TO SUPPLY AND INSTALL GRAPHICS. PRE - FINISHED/ PRE - FABRICATED 3/4' M _D. F. PANELS uu✓ ALMOND FINISH PROVIDED BY OWNER, INSTALLED BY G.C. ('T'YP.) ON WC>IDD FRAMING AS 56 N I B-2 j l/2 Tl om RBGESew 04000 BASE ON MASTIC (G C TO SCRIBE TO f) CVER 3✓4 PLYWOOD r 1 1I c'�,ppR rwG 4C (SEE Iti.,r 0/4 $ 144I,.4. rw + PLAN) O Q EXISTING MALL LIGHT COVE TO REMAIN. G.C. TO PROTECT DURING CONSTRUCTION NEWLY RE- MODELED MALL BULKI -IEAD. G.C. TO COORDINATE WORK W/ LANDLORD. G.C. TO PAINT 3 5/8" x 18 GA. ! METAL STUDS IP 16" O.C. 5/8" PAINT I P -10 I P -10 ' YPSUM BOARD; PORTION OF EXISTING MALL BULKHEAD TO BE REMOVED (S1-40WN DASHED). REFER TO STOREFRONT ELEVATION 4 CONSTRUCTION PLAN FOR EXTENTS. 14' -0' A.F.F. (V.I.F.) MALL COVE 13' -6' A.F.F. 13' -O" A.F.F. MALL BULKHEAD (REWORKED) 3 5/8' x 18 GA. METAL STUDS 0 16" O.G. 2) 15/8 "x12 "x16 GA. METAL JOISTS Sum. 10' -11" A.F.F. MT -1 V, (ALMOND) BREAK METAL CLADDING OVER 5/8' TYPE "X' GYPSUM BOARD (G.C. SUPPLIED) (TUCK ALL ENDS) CESSED CAN LIGHT - REFER TO REFLECTED LIGHTING PLAN. LEASE LINE AND PRE - FINISHED DARK BROWN STAINED e4ARDWOOD GLAZING MEMBER BEYOND COINCIDE. SF -3 PRE- FINISHED/ PRE - FABRICATED 3/4' M.D.F. PANELS (INSIDE DISPLAY ONLY) PROVIDED BY OWNER, INSTALLED 13Y G.C. (TYP.) ON F.R.T. WOOD FRAMING AS SHOWN. BUILT UP COLUMNS AND BLOCKING BEYOND TO EXTEND DOWN TWRU PLATFORM AND CONNECT TO SLAB PRE- FINISHED/ PRE - FABRICATED 3/4" M_D.F. PANELS w/ ALNOND FINISH PROVIDED BY OWNER, INSTALLED BY G.C. (TYP.) ON F.R.T_ WOOD FRAMING { G C ...o PRE- F31yaSHED DARK 8RL7F1N S'A:MED : .RD 4001) GLAZING MEME ER BEYO D, OVER (2) LA"'ERS OF 314• F R _ T x"Ln 000 5UI3F'LOCIR ON 3 " (S GA) r" ErA4.. J B- s 1112' TwwCX RECESSED T LE giiitZ MASTIC (G.C. TO SCRs TO FLOOIR) OVER 3/4 F _L. T PLY 64000 c. 9164ALL SE ROUP00054SLE FOR P'RL7VnDWG A F16.4 .41b4 spicaru "TRANISTIION APO TIDY` Pacatom EX'S NG " - r4... IrLO R NG IILINWIAC* L OW*06 (SEE Ov0 a so"-, htSi+ D. AI%) O c c STOREFRONT SECTION THRU DISPLAY SHREMSHOCK ARCHITECTS, INC. 6130 S. SUN BURY ROAD SUITE 100 COLUMBUS ON 43081 614- 545 -4550 www.shremshock.com co co 0 0 O \ 6923 REGISTE ED I '' ''''' ARCHITE GERALD S. SHREMSHOCK, STATE a YY'ASHINGTON (1) DOE OESIONED IT. Br: CHECKED O o i- z -' 0 W i-- mon CC W w- JZzv� * =3 W u J _ M 17- z 0 . I---" Z O H Z Z Z » f a W C Fyi C.1) t L 0 0 REVISIONS: 1 amorms .e aroma it - ion- tr; 0 0 STOREFRONT SECTIONS es DETAILS A08.5 r • H Q~ r d O M J � U .( W *1 !! ! :!! .0 W Z z e ...„..._ 3 � iW U .' 2 - W'-0 n =QnOOZ Z Z V Za. WW 3 ` O 4Z~►z t im 2 N IA • 7 zOOY� iV— ;= ✓i.W- - O BJ ;� �'0r �2 ZtV4 ~i0- 34t�3 WO XEXX t:00 C7�OWW O5.1 OOrc V �Z. r Ch V V 4 Z O �:) _CI CN M N ▪ M 0 O 0 W 0 0 N Vl ©r z �� Q O O 0 J 0 0 xet Lai • ta a a ' Z CI N - n-« V N. Is • 4 i t a • s 4 • D T an n (-4 1 n ♦• Q. 4'4 n r IA gi • O O ;t CD MEM PPH 1 O � D m Q N Q -4 Ma 0 = -1�A cR %to L7x =D3 r cr � N I mz- 1 2 Nz, A V l gi3 mim z r -3 .8, oo z Arp C n- EiA r D r r Cyr 3 z l i( r to D - I v 712- • � Ell o�oPr r — m O o -4 � `3 zr - 4 m Orn rE 700 0= g �i1 O Z 0 C rn z O C Ca rn v 9 n In n r m 0 n r m C Z 0 C rn 1, 2 m a m n 5 2 o1 P I v� 3 PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA lEtes SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSDC PROJECT #: 00043770 A/E PROJECT #: 0100688 032Fb 03341/03132 PRDHIBITIQN ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., D/B /A LIMITED STORE DESIGN AND CONSTRUCTION (“LSDC`). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC, ND REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. CQ?T1LQ 11 MICE; THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN * ARCHITECTURAL WORK' UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSAI 01 CONSTRUCTION, NUILDiNG SEIZURE, AND /OR MONLIARY LIABILITY. Limited brand LIMITED STORE PLANNING, INC. d/b /3 STORE DESIGN & CON; J RUCTION I hr* e 1. in• t€'ci Parkway t: i3i:lt+ bus, Ohio 43:7K rf', Nphone: 614,415 MOO F ax 614 415,7349 Fxttp..1 www !.. SI.Th(. .I irnitc9€ l3rand con f B - I SURFACE- MOUNTED WOOD BASE CUT TO FIT, GLUED AND NAILED TO 1/2" F.R.T. PLYWOOD OVER 3 5/8" 18 GA. METAL STUDS # 16" O.G. (G.C. TO SCRIBE TO FLOOR). WOOD BASE SECTION 1 BRIDGING BETWEEN RIBS, G.G. TO SCREW • 6" O.C. SINGLE TUBE F FIXTURE, A.F.F. 2 1/2" $'_1' -0" 01SA101A0 M CEILING TRANSITION ABOVE 2 3/4" ETAL STUDS " GYPSUM BOARD ON /2" F.R.T. PLYWOOD 3 5 /B" METAL STUD I PANELBOARD ISTING DEMISING NICHE - PILASTER DETAIL 5/8' GYPSUM BOARD ON 2 1/2" METAL STUDS IP 1 • O_C 3 I/2" "E STUDS • 1i' C_C S' F For E: BoT'TQ'I' ! 13' A_F FILLER PANEL TO k: p4rr TOP OF LEDGE LICE OF DesPLAY "-EDGE sm" GT.Sulm WARD Coi 3 Ste` 1T/►L STUlR7lS • O_C. \ REFER - ""r.: CJ'*s 3 5/8' NE!A4 STUD 2 3/s' S BOA STUDS FACE OF WALL LINE OF CEILING TRANSITION ABOVE. FILLER PANEL T W ITN TOP OF LE 5/8' GYPSUM BOARD ON 1/2' F.R.T_ PLYWOOD -�' A i, 2 -0' NICHE - PILASTER DETAIL ONE OF BASE BELOW t SF-2 i PANE1.eL>IA1tD FACE CIF EXISTING QU— • MALL 314" F.R.T. Boom* BEET 4A'r -r I4ED TO STLICS 7 t /Y -T-O' o�w1oLO I K DEMISING WALL - REFER TO CONSTRUCTION PLAN 5/8" TYPE 'X' GYPSUM BOARD ON 3 5/8" METAL FRAMING • W O.C. REFER TO REFLECTED LI GI-IT ING PLAN REFER TO REFLECTED LIG-ITING PLAN 3 5/6" METAL STUDS • 16" O.G. 5/8" GYPSUM BOARD SINGLE TUBE FLUORESCENT FIXTURE SF -2 IPANELBOARD 1/2" PLYWOOD STRIP AT EACH ROW OF PUCKS. PUCK 3/4' F.R.T. PLYWOOD BACKING SWEET ATTACHED TO STUDS. SCREW T14ROUGI -1 PUCK WOLE (COUNTER SINK) PRIOR TO INSTALLATION OF PUCK COVER 5/8" TYPE 'X' GYPSUM BOARD ON 3 5/8" METAL STUDS # 16" 0.G. BY G.G. 5/5" PLYWOOD STRIP TOP 4 BOTTOM_ DISPLAY LEDGE PROVIDED BY OWNER, INSTALLED BY G.G. - REFER TO SWOP DRAWINGS FOR CONNECTION DETAILS. RIBS • 12" O.G. DUPLEX OUTLET (WHERE APPLICABLE) CENTERED AS SWOWN; REFER TO ELECTRICAL DRAWINGS 5 -2 i SURFACE- MOUNTED WOOD TO FIT, GLUED AND NAILED TO 1/2" F.R.T. PLYWOOD OVER 3 5/5" 16 GA. METAL STUDS iP 16" O.C. (G.C. TO SCRIBE TO FLOOR). NICHE - SECTION 5/8' GYPSum BOARD ON 2 1/2" METAL STUDS • 16" O.C. 5/8" GYPSum BOARD ON 3 5/8' METAL STUD S/8' GYP. BRD_ ON 3 5/8' METAL STUDS ! Kr' O.C SiNGI E "'^LSE FL URESCDN'" F X RE. BOTTOM • 13' A_F F'LLER PANE. 1 'o ALIGN Iris 'w TOP OF L EIc FACE OF EXYST1NG DET"IMING i4ALL SF - 2 �a LIFE OF BASE D-2 BELON e!/4 F_RT. /tiT D MOMS BEET ATTAQ* TO STUDS B -1 BASE BEYOND NICIE - PILASTER DETAL MILLers.. mar imih, a /s' I' 5 _ :2 3/4" '--6" 10' REFER - C ' � CONS a...Aik. I TOP OF PLYWD P 10' -4 1/2" AFF 2 1/2" METAL STUDS 0 16" O.G. SCREW 0 6" o.C. G.C. TO COUNTERSINK t PUTTY (COLOR TO MATCH. ) 2 x 4 NA I LER (TYP. ) BRIDGING BETWEEN RIBS, G.G. TO SCREW 0 6" O.G. I •xT-0' o�►1o�o, H 5/8" GYPSUM BOARD ON I /2' F.R.T. PLYWOOD LINE OF CEILING TRANSITION ABOVE. LINE OF DISPLAY LEDGE BELOW 1 ' - 2 -C" Jr :0 si V In 0 0 6 6 a 0 2" 10" CRITICAL ALIGNMENT: +--� TOP OF LEDGE TOP OF RECESSED BASE NICHE - ELEVATION NICHE -PLAN DETAIL 2' -O" 1 -0" / 1' -O" I'-0" I' -0" r 4'-0" I SF -2 LINE OF SOFFIT ABOVE FACE OF DISPLAY LEDGE BELOW V4' IF _RT_ pLywOOD SACKING SET ATTACHED TO STUDS PREFINISHED PANELBOARD DISPLAY SYSTEM SF" -2 i. � � iF' DISPLAY 2' -0" VARIES - REFER TO CONSTR;XT iON PLAN r L B -2 I 6' NIGH 1400D BASE PUCK 4' -0" 2' -0" PUCK 10" 2" LINE OF F.R.T. PLYWOOD BACKER BY G.C. DISPLAY LEDGE SEAM FACE OF DISPLAY LEDGE RECEssED BASE BELom TOP OF PLYWD . 10' -4 1/2" AFF r B - L 12' N. TILE BASE • FRONT OF PILASTER NMINg i 11•111•111•111111111t UMMEM— 1- -111111111, ■�7 P -10 LI ±► -` r ~ REFER TO REFL. LIGHTING PLAN ir REFER TO REFL. , LIGHTING PLAN • TsT-O' I O�A/0�0 � B U W CZ CL. SHREMSHOCK ARCHITECTS, INC. 6130 S. SUNBURY ROAD SUITE 100 COLUMBUS. QM 43081 614- 545 -4550 www.shrimshock.com co co co 0 0 C CID --(112) 0 Z C:: rO O .t ' 7 ,, I ) - - NID (0. 1-: Li_ i , , (1) ,.......a — ..,.., — •}} 4.) 11.1 C:1 W J - � W :a _ Z ZA (.) i3 N X P .M 0) bt • ..cats .e ammo w— DATE ISSUE& DESIGNED BY: DRAWN VT: CHECKED eV: 69 3 REGISTERED CHITFCT REVISIONS: ,, O t r U- u :' Z - Y m GOtL7►= j t Z = WIr�WQ rS. -Z = tc'Jn= z xaa iy aN.1 O t2u z: cl: W V c a V "'# . = O a'c J 6 M O O zM t� O �0W =OW d y1 0 m n ar 2 �- = o Z O x z Z '_ 0 aLH`tW it r VO 0 t .' O W0 „►- P p ma � 0 Y WD Vf F x W 2 Y W 41x2WL,,, D 00� ;� V pm i Q ►-r WaC t a rrtW aC 3t W OW � z W r3Z ~ V aC o 2 Z W CW� KCO' ~ =Z ► - O V a� J a0 W.- o V 3 O O Z ` W : : Q r y W 0 U Z:' ti Zj0 =QJ 0x „ m z.. , Z ,,z W i 0 O- m 3 o Oau uwW VQ(jWOUOV v � �o a I.`� -2 a,7 W WNaVZ-1 W ti = V h2 z taZ�Z�OW U mW Q W j a r W x 0 ` X Z v x JaL „ Z x Z „ m z - ,A • x i. -' W a V OWN Z' „ aRZ 0 0,., V „ -.7* C 5 0 z O -WYI r4.' I...nar 11 .5 11 ,6 2 . ; 6_ 0 12 a c ?arc�a1aa1 W n a ac D �' W a 7T. - a[ a W a rrr „- F � O� �n all Q = =L►NCJ00 zaaa nz -o noWW x OZz__ Z= ^...«`JW.- 5x 00aavuZ . .-u0an 11... m3„ {m0 .- UVa =07 U NICHE LEDGE DISPLAY DETAILS 'RIMINI; MOM A10.1 t`J 1.- M .— M M 0 0 M M 0 �.� (7) 0r. z24 0 0 0 0 0 0 J U O Q. W Z V d V VW • O VI O J C I 0/16/C3 SF Par ass • • • le • • i i► I ; 1611 V9 la LIEU Gil lI I 0 0 0 ® 3 1/2" ® L' ® 0 0 © 3 1/2" 4 El DI 0 0 i ® CI J ® if ® 0 0 ® L B - I SURFACE- MOUNTED WOOD BASE CUT TO FIT, GLUED AND NAILED TO 1/2" F.R.T. PLYWOOD OVER 3 5/8" 18 GA. METAL STUDS # 16" O.G. (G.C. TO SCRIBE TO FLOOR). WOOD BASE SECTION 1 BRIDGING BETWEEN RIBS, G.G. TO SCREW • 6" O.C. SINGLE TUBE F FIXTURE, A.F.F. 2 1/2" $'_1' -0" 01SA101A0 M CEILING TRANSITION ABOVE 2 3/4" ETAL STUDS " GYPSUM BOARD ON /2" F.R.T. PLYWOOD 3 5 /B" METAL STUD I PANELBOARD ISTING DEMISING NICHE - PILASTER DETAIL 5/8' GYPSUM BOARD ON 2 1/2" METAL STUDS IP 1 • O_C 3 I/2" "E STUDS • 1i' C_C S' F For E: BoT'TQ'I' ! 13' A_F FILLER PANEL TO k: p4rr TOP OF LEDGE LICE OF DesPLAY "-EDGE sm" GT.Sulm WARD Coi 3 Ste` 1T/►L STUlR7lS • O_C. \ REFER - ""r.: CJ'*s 3 5/8' NE!A4 STUD 2 3/s' S BOA STUDS FACE OF WALL LINE OF CEILING TRANSITION ABOVE. FILLER PANEL T W ITN TOP OF LE 5/8' GYPSUM BOARD ON 1/2' F.R.T_ PLYWOOD -�' A i, 2 -0' NICHE - PILASTER DETAIL ONE OF BASE BELOW t SF-2 i PANE1.eL>IA1tD FACE CIF EXISTING QU— • MALL 314" F.R.T. Boom* BEET 4A'r -r I4ED TO STLICS 7 t /Y -T-O' o�w1oLO I K DEMISING WALL - REFER TO CONSTRUCTION PLAN 5/8" TYPE 'X' GYPSUM BOARD ON 3 5/8" METAL FRAMING • W O.C. REFER TO REFLECTED LI GI-IT ING PLAN REFER TO REFLECTED LIG-ITING PLAN 3 5/6" METAL STUDS • 16" O.G. 5/8" GYPSUM BOARD SINGLE TUBE FLUORESCENT FIXTURE SF -2 IPANELBOARD 1/2" PLYWOOD STRIP AT EACH ROW OF PUCKS. PUCK 3/4' F.R.T. PLYWOOD BACKING SWEET ATTACHED TO STUDS. SCREW T14ROUGI -1 PUCK WOLE (COUNTER SINK) PRIOR TO INSTALLATION OF PUCK COVER 5/8" TYPE 'X' GYPSUM BOARD ON 3 5/8" METAL STUDS # 16" 0.G. BY G.G. 5/5" PLYWOOD STRIP TOP 4 BOTTOM_ DISPLAY LEDGE PROVIDED BY OWNER, INSTALLED BY G.G. - REFER TO SWOP DRAWINGS FOR CONNECTION DETAILS. RIBS • 12" O.G. DUPLEX OUTLET (WHERE APPLICABLE) CENTERED AS SWOWN; REFER TO ELECTRICAL DRAWINGS 5 -2 i SURFACE- MOUNTED WOOD TO FIT, GLUED AND NAILED TO 1/2" F.R.T. PLYWOOD OVER 3 5/5" 16 GA. METAL STUDS iP 16" O.C. (G.C. TO SCRIBE TO FLOOR). NICHE - SECTION 5/8' GYPSum BOARD ON 2 1/2" METAL STUDS • 16" O.C. 5/8" GYPSum BOARD ON 3 5/8' METAL STUD S/8' GYP. BRD_ ON 3 5/8' METAL STUDS ! Kr' O.C SiNGI E "'^LSE FL URESCDN'" F X RE. BOTTOM • 13' A_F F'LLER PANE. 1 'o ALIGN Iris 'w TOP OF L EIc FACE OF EXYST1NG DET"IMING i4ALL SF - 2 �a LIFE OF BASE D-2 BELON e!/4 F_RT. /tiT D MOMS BEET ATTAQ* TO STUDS B -1 BASE BEYOND NICIE - PILASTER DETAL MILLers.. mar imih, a /s' I' 5 _ :2 3/4" '--6" 10' REFER - C ' � CONS a...Aik. I TOP OF PLYWD P 10' -4 1/2" AFF 2 1/2" METAL STUDS 0 16" O.G. SCREW 0 6" o.C. G.C. TO COUNTERSINK t PUTTY (COLOR TO MATCH. ) 2 x 4 NA I LER (TYP. ) BRIDGING BETWEEN RIBS, G.G. TO SCREW 0 6" O.G. I •xT-0' o�►1o�o, H 5/8" GYPSUM BOARD ON I /2' F.R.T. PLYWOOD LINE OF CEILING TRANSITION ABOVE. LINE OF DISPLAY LEDGE BELOW 1 ' - 2 -C" Jr :0 si V In 0 0 6 6 a 0 2" 10" CRITICAL ALIGNMENT: +--� TOP OF LEDGE TOP OF RECESSED BASE NICHE - ELEVATION NICHE -PLAN DETAIL 2' -O" 1 -0" / 1' -O" I'-0" I' -0" r 4'-0" I SF -2 LINE OF SOFFIT ABOVE FACE OF DISPLAY LEDGE BELOW V4' IF _RT_ pLywOOD SACKING SET ATTACHED TO STUDS PREFINISHED PANELBOARD DISPLAY SYSTEM SF" -2 i. � � iF' DISPLAY 2' -0" VARIES - REFER TO CONSTR;XT iON PLAN r L B -2 I 6' NIGH 1400D BASE PUCK 4' -0" 2' -0" PUCK 10" 2" LINE OF F.R.T. PLYWOOD BACKER BY G.C. DISPLAY LEDGE SEAM FACE OF DISPLAY LEDGE RECEssED BASE BELom TOP OF PLYWD . 10' -4 1/2" AFF r B - L 12' N. TILE BASE • FRONT OF PILASTER NMINg i 11•111•111•111111111t UMMEM— 1- -111111111, ■�7 P -10 LI ±► -` r ~ REFER TO REFL. LIGHTING PLAN ir REFER TO REFL. , LIGHTING PLAN • TsT-O' I O�A/0�0 � B U W CZ CL. SHREMSHOCK ARCHITECTS, INC. 6130 S. SUNBURY ROAD SUITE 100 COLUMBUS. QM 43081 614- 545 -4550 www.shrimshock.com co co co 0 0 C CID --(112) 0 Z C:: rO O .t ' 7 ,, I ) - - NID (0. 1-: Li_ i , , (1) ,.......a — ..,.., — •}} 4.) 11.1 C:1 W J - � W :a _ Z ZA (.) i3 N X P .M 0) bt • ..cats .e ammo w— DATE ISSUE& DESIGNED BY: DRAWN VT: CHECKED eV: 69 3 REGISTERED CHITFCT REVISIONS: ,, O t r U- u :' Z - Y m GOtL7►= j t Z = WIr�WQ rS. -Z = tc'Jn= z xaa iy aN.1 O t2u z: cl: W V c a V "'# . = O a'c J 6 M O O zM t� O �0W =OW d y1 0 m n ar 2 �- = o Z O x z Z '_ 0 aLH`tW it r VO 0 t .' O W0 „►- P p ma � 0 Y WD Vf F x W 2 Y W 41x2WL,,, D 00� ;� V pm i Q ►-r WaC t a rrtW aC 3t W OW � z W r3Z ~ V aC o 2 Z W CW� KCO' ~ =Z ► - O V a� J a0 W.- o V 3 O O Z ` W : : Q r y W 0 U Z:' ti Zj0 =QJ 0x „ m z.. , Z ,,z W i 0 O- m 3 o Oau uwW VQ(jWOUOV v � �o a I.`� -2 a,7 W WNaVZ-1 W ti = V h2 z taZ�Z�OW U mW Q W j a r W x 0 ` X Z v x JaL „ Z x Z „ m z - ,A • x i. -' W a V OWN Z' „ aRZ 0 0,., V „ -.7* C 5 0 z O -WYI r4.' I...nar 11 .5 11 ,6 2 . ; 6_ 0 12 a c ?arc�a1aa1 W n a ac D �' W a 7T. - a[ a W a rrr „- F � O� �n all Q = =L►NCJ00 zaaa nz -o noWW x OZz__ Z= ^...«`JW.- 5x 00aavuZ . .-u0an 11... m3„ {m0 .- UVa =07 U NICHE LEDGE DISPLAY DETAILS 'RIMINI; MOM A10.1 t`J 1.- M .— M M 0 0 M M 0 �.� (7) 0r. z24 0 0 0 0 0 0 J U O Q. W Z V d V VW • O VI O J C I 0/16/C3 SF Par ass • • • le • • i i► i s PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: REMODEL /DOWNSIZE DESIGN TYPE: ALMOND LSDC PROJECT #: 00043770 PACKAGE: GENERATION: A/E PROJECT #: 0100688 032Fb 03341/03132 PROHIBITION ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., 0 /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC "). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. COPYRIGHI HOWL THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSAIION Of CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIAMIL.ITY. Limited brands L.M1 TED STORE PLANNING, INC. d /b /a STORE: iD SIGN & CONS FRUCTI .SIN flr et? Limited Park way Columbus. Ohio 43 I twit #;thOft;' 614.41b 7000 • 1 614.415 /: 4t) rat tE.3: wvv.►v t S )fn( t_ u i eciF3r al ci c.c�r� s I a f 4 a n n 5 n amo ( 14 ;c1 A z 1" f /Z" f / - pit; 9 r16. a'P rt; g 1; 141: i 1 il PH 14 l'i§ ! ' or 1 Wil i 1 6 0 n iut 0 1 1 82 MIEN UI L1 1: 4 A linEm 1 -6 I /4" ()q F 2 F i /2" F A rn a -471g f'(D z t j t? O ? Z � N - J0D rnN 1d z r. C_I FIT I.� 7r� co Z 0 cn C m v r n a 00 m m 0 0 z I y I I 1 -0 3/4" z O ma, 1 • q' -4 3/4" CABINET VERTICAL ROUGH OPENING 3X m3 to O z in i� 70Xp O 13rp p 1 l rUz r n r -ir m Pi a�- z J 11 m 70 0 70 -4 -on et z- oz i m m 3 m rn 70 O O 0 ig a FA Min to i 1, r PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA oEtee SCOPE: RE. MOW. L /DOWNSIZL PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSO&C PROJECT #: 00043770 A/E PROJECT #: 0100688 032Fb 03341/03132 PROH191tI ON LUSL THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DESIGN ANO CONSTRUCTION ( "LSDC'). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SMALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSOC. CCIPIRIGIII _ HOLM THESE DRAWINGS AND SPECIFICATIONS ART COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSAIIUN Of CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY. I i m itec brands LIMITED STORE PLANNING, INC. d /b /a STORE DESIGN 84. CONSTRUCT! NI Tree I.. TITIited Park way • Columbus. Ohro 432 3 : 'telephone.: 614.41 5. /000 • }-ax: 614.41;;,. / >49 htti) :; . www.I I:::31�f �. #..irrTttE r:t(r E't.f:.t;r�rTI >E to A VI O! VI i c 46. co = 3 4$ g M uI 3 i C'1 p ,„ 3 os O -4 O to n • E 4 i • s 4 S a n mu r 1 y co O 3 Tv N 11 rn 0 to 6 111111111 EXTENT OF 16 GAUGE IN WALL S4 -IEET METAL BLOCKING r_ z ii Z r_ P z Z 1 -0 rn A, 0 m 11 m A m 0 m N 131 W 1 BASE Tt EXTENT OF SF -1 PANEL. REFER TO INTERIOR ELEVATIONS FOR PANEL I- 4E1G14T T l i mo ( T L, 71 0 ✓ > I b I lig A 1 r tit g TIE di I —18x P>1 .; or> . o au at 11 W rr PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 9E18E SCOPE: RLMODCL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043 710 A/E PROJECT #: 0100688 032Fb 03341/03132 PITD tHESE HTSITION DRAWINGS 9N AN REQ5L D SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME, REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROH181TED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY ( LIM"LSDC ITED ") STORE , PLANNING, INC., D/a/A LIMITED STORE DESIGN AND CONSTRUCTION THESE DRAW +NGS AND SPECIFICATIONS ARE THE PROPERTY Of LSDC AND SHALL NOT Sr DISPIAYFD IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL 8t MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC, ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC CQP1(R1GHI MQIICL; THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL W R Y H PROTECTION WORKS COP RIG T ROTECT ON ACT OF 1990, THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSATION 01 CONS, RUCIION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY„ I i m itec Three I ,rt f 11 Parkway t.:i;€ rt��t�iIti , e132 i,I I t its phone 614.41b. 70U) . Fax 614.4%). - ). / 3 :14 http.:/wvvw.E. t initt::(1Brard c:«r Lrands LIMITED STORE PLANNING, !NC. d /b /a STORE DESIC:3 CONSTRUCT ON U, - 7 0l !V W X C7] -4 kC, - C) 3 >E 4:1)0u) c � r • r- is (RE m 3103 g • U f -( O-4 c:4 y z F.) 4 s • 4 t c 1/4 "/ f • • • 1= .MI=Ig 11: 2' _0' (1 to r I I Tl 3 .10 Il4" T -0" 2 H iq 3/4" 3/4" z D m 1/4" to 1/2" i" SIDE SUPPORT 0 rn a 0 Z 0 Ca c m v w c� 1 0 0 1, Z m v co rn n z t cn co A 410 w ■ h m r W t' 1/2" 34 mcs� D mm r 0 70n � . O c al gx P2 O 3z .* D-4 2 ppv 0 W N? w 1 1/2" 1 i «'0 O D -I -I o o m . �X 070 0 w z: vn -40 r mc - Nn mF Z to m 6. D 3D j v z IN XI m r + or Om n v rn m r O C) i i a t 3 t. iQ T PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD &C PROJECT # 00043770 AjE PROJECT O: 0100688 032Fb 03341/03132 PROHIBITION OH REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME, REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY ( " LIMITED LSDC ") STORE . PLANNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION Of THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST RE RETURNED TO LSDC UPON COMPLETION Of THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. OOPYKIG I QlICL THESE DRAWINGS AND SPECIfICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 Of THE COPYRIGHT ACT. 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION 'NCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS Of THE DESIGN. UNDER SUCH PROTECTION, UNALIIHORIZED USE Of THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CkSSA■ON U+ CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY, Limited bran's LIMi TES) STORE PLANNING, INC. dlb /a . -)TORE DrSI N & CONSTRUCTION # tr 'e t_Im lfxd Pwk way Coluottis. Ohio 43'230 I eleIatIOI tJ 614.116.r00k) • way: 614.41=:,.7349 tit try: ',`'Nww.t.. ;. f.: tiC.;.L. imitecdt3rand`-, co,,I TV CA) O l 3 4E O' n (nm EA r 2. 16m ..+$n = los n o Os O -s J >y o n • e 1T r 4 a l�J n z 4 Z O C cn rn n cn ec• co m c� 0 z 0 y i Co T C, a cz) N I 0 1 0 o I I 0 1 ° N 5 1/2" \5 1/2" 2' -10 1,2 tt �z rm r N co n Z 0 C rn C, r z m 2 -10" w C) a) m 2'-10" p3 0 ;5,1 • 4 PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 A/E PROJECT #: 0100688 032Fb 03341/03132 PNDH1e1IQ 9N REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIIED IN WRITING BY LIMITED STORE PUNNING, INC., O /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC'). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT RE DIN ATM IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH (SOC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO ISOC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. COPYRIGHT NOTICE; THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 10Z OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES. AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSAI■ON UI CONSTRUCTION, IlUILUINU StIIUNL, AND /OR MONETARY UABltilr. = (0 T I -4 rIn l IE ch vi al in * r , C :74 O Col rI 6 U4 �m.".Vf= '43 g LimItedbrands L MITEyE.) STORE PLANNING, INt._.:. d'h /a STORE [. F }I IN 8, CONSTRUCTION 2 ( tirte Limited Pat - (' Ufa.TmbI.1s_ GIUC 4 ;':s I it:°))1It:)tte: 614.415 14:00 - 1 cl.k: 514 41513 itr :zt� . :OM ) LAMINATE •iiii ]- -- - 1 r NANGERTIGNT UNIT ►MINATE ADJACENT SHELVES i •t LI � L WANG ERTIGHT UNIT .1 -II { I lc , _ ADJACENT SHELVES LA •iiii ]- -- - 1 r NANGERTIGNT UNIT ►MINATE - I LAMINATE 2' -1 7/8" 2' -I 7/8" .1 i t • • i • 4 a THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 96166 SCOPE: RCMODEL /DOwNSILE PACKAGE: DESIGN TYPE: At.MOND GENERATION: LSDC PROJECT #: 00043770 A/E PROJECT #: eROMB11ION ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE 0R AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIIED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC "). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. COPYRIGIiI NOIIM THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1 990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION Of SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSAI ON 01 CONSIRUCIION, klUILOINU SWUM., AND /OR MONL?AINY LIANILIIv. LIMITED STORE PLANNING, INC. d /b /a STORE DESI GN & CONSTRUCTION l I Et +t1. d Park way • Ct)lLar,1t)u O uo 432x3() e 6 4.4 ;, ?t.:)f3 itX 6it4 416./.349 • wkAivv.i. 1th& (•if3i a, or,; NOT USED PLATFORM SECTION (TOILET /OFFICE) BRACING DETAILS SCALE M 2' x4' LAY-IN CEIL 3 5/8' x 20 GA. PAINTED (FACTORY PRIMED) METAL STUDS • 16" O.C. WITH CONTI TOP 4 HOTTQM TRACK 6 X I6 GA. STEEL O.C. W/HORIZONT PER MANUFACTU RECOMMENDAT 104/STUDS B . ALIGN x 16 GA. METAL ING • 16" O.C 3/4" CDX PLYWOOD DECK OVER 5/8" GYPSUM BOARD 1 1/2• =7-0" 01SAl2'LO FASTEN DEFLECTION PLATE SA F I NG MATERIAL SEALANT W/ BACKER ROD 1 LAYER TYPE "X" GYP. BD. FASTEN MIL . STUD TO RUNNER 1/2' DEFLECTION SPACE (DO NOT FASTEN RUNNER, STUDS, OR GYP. BD. TO COMP. TRACK) RUNNER TRACK UL LISTING NUMBER: #HW5 -00178 DETAIL AT DEFLECTION PLATE 3":1'-d" 01SAl21J0 ri )# t 3/4" CDX PLYWOOD DECK OVER 5/8" GYPSUM BOARD ON 6" X 16 GA METAL JOIST • 16" O.C. l / -- SAND ALL EDGES SMOOTH 1 x WOOD TRIM - RUN CONTINUOUS ALONG TOP EDGE OF WALL 16 GA. METAL CHANNELS S' -0" A.F.F. B.O. CEILING 3 5/8' X 16 GA. PARTITION - ALIGN STUDS DIRECTLY UNDER JOIST (TYP.) 5/5" GYP. BOARD, SEE FINISH PLAN E SCHEDULE. 3 1/2" FRICTION FIT BATT INSULATION NI GA. CONT NUOU TOP "RACK EFER TO ELEV_ TR .JCTURE/DECK VARIES 5.0- (E) FINISHED CEILING (Y•IERE OCCURS) 5 Q ; ti; CE _'`rG 5/e' TYPE IC GYP. BD_ CEILING PLATFORM SECTION (TOILET /OFFICE) SECTION THRU CORRIOR PARTITIONS ,2" =1'-O" O1SAl21'i0 T H 0 BRACE STUDS TO NDERSI DE OF STRUCTURE REQ'D BY CODE .F.F. CONSTRUCTION LEGEND ACTORY DS • 1 0 U.N. PLAN /WA 35/8 "X16GA. PRIMED METAL S 16" O.C. MOUNT 8' -0• WALL STANDARDS ONTO HORIZONTAL FURRING. 1'X2" WELDE (ONE SIDE WIRE MESH • WALL TYPE AS SI-10#4N ON LEGEND NON -SALES AREA (STOCKRQQ0 ) S R F R T ) STRUCTURE / DECK CONTINU SEALANT OF PARTITI 3 5/8" TOP 4 BOTTOM TRACKS ANCHOR TO STR ABOVE • 24" O.C. MAX. AN FROM EACH END. (PROVIDE DEFLECTION PLATE AT TOP A REQ' D BY CODE. ) 3 5/8' X 20 GA. METAL STUDS • 16" O.C. BASE AND FLOOR FINISHES. (SE PLAN AND INT ELEVATIONS AL TURE " INISH IOR a WALL TYPE AS 514014IN ON LEGEND UL LISTING NUMBER: *U465 SHREMSHOCK ARCHITECTS, INC. 6130 S. SUNBURY ROAD SUITE 100 :.. 4 .4,, ,,� COLUMBIA +1 43081 614- 545 -4530 - www.shr.mshock.com W • m u mz .n �0 U O . K u * 1 1 0:7, a N �[zWa ? O z - ~ Z • i- Z i ttt i a ....m O Y cry 0 t =MWW0 W .11....;= W M a< aC r X dWW W W eei4:1 3 Z . 0 y W _ W CC �► r' _ ` .-.I 4).- - - fEar 2 z_:= O 0 y 00 ;=0 2 =y0 <W # 4 W w. O e r -d .- vi•- W - x0z 00-40, r GE S. SHREMISNOCK ATE OF WASHINGTON * j - 00 • UfN Z E Z ▪ w m OJ O - W • . 4 i ar WN v�iO v X x+011= 20 200.0n22 ,[ .ic 2 0 0 W W2= �¢2D 017 �`Pc arC,?.[ 3Q~ a. �N � W .� O .i W O *.) i W rn � � =Z lO - tOg3 zvi2 -L v+ c_ z zF a. x z � O p3Zpy i t - ;2 J 0 yvi y O m O2J 4 t✓1 W = zoo,,, • � - .,,r�+ eiir Nt - �a c�> � - =.1 vi • 0 Q . '�y�05z O O oa� a4 41-Ww. !. >. 7:7:< _J n .� OOZ OOarUrz�, � c�ci�c=0av (MITE GSM SEW= Sr: ORNIIIN U: CIIIIMIED /Y: 27 0 r > r p F :27 LiJ C' rr. L.1...! E r.. 0 0 PARTITION DETAILS N La- M N M M 0 0 M 0 t ' /'` 6,/C3 C F MOP NON -RATED PARTITION (NON - SALES) VARIES REFER TO ELEV B.O. (E) STRUCTURE / DECK CONTINUOUS FIRE RETARDANT SEALANT * TOP AND BOTTOM OF PARTITION, BOTH SIDES. 3 5/11' TOP 4 BOTTOM METAL TRACKS ANCHOR TO STRUCTURE ABOVE • 24" O.C. MAX. AND 2" FROM EACH END. (PROVIDE DEFLECTION PLATE AT TOP AS REQ'D BY CODE.) BASE AND FLOOR FINISHES. (SEE FINISH PLAN AND INTERIOR ELEVATIONS. ) s WALL TYPE AS SHOWN ON LEGEND UL LISTING NUMBER: *X527 2 -HR. RATED PARTITION FURRING WALL ITWJ 1 1/2"_r -O" O1SAl2''O 1 1/2"=r -O" 01SAl2E0 F E VARIES REFER TO ELEV . 0_ (E) STRUCTURE (E) WALL PARTITION ('E) IFLLx'IR SLAB I I • 1104.L TYPE AS SIAM al LEGEND D 1 -HR. RATED PARTITION VARIES REFER TO ELEV 8.0. (E) STRUCTURE 314 STTROOM 5/8" GYP. BD. BOTH SI DES 3 5/8" X 20 GA. METAL STUDS 16" O.C. BASE AND FLOOR FINISHES. (SEE FINISH PLAN AND INTERIOR ELEVATIONS.) (E) FLOOR SLAB 1 • WALL TYPE AS SHOWN ON LEGEND SIM. SALES FLQOR FINISHED CEILING NON -RATED PARTITION (TO STRUCTURE) NON -RATED PARTITION 1 1/2 " =1' -O" 01SAl21C0 1 1/2" :1 01SAl210 VARIES REFER TO ELEV B.O. (E) STRUCTURE 3 6/8' TOP * BOTTOrl METAL TRACKS ANCHOR TO STRUCTURE ABOVE • 24' O C. MAX. AND 2' FROM EACH END. (PROVIDE DEFLECTION PLATE AT TOP ASREQDBYCODE.) FINISHED CEILING (WHERE 5✓8' GYP. BD_ BOTI'+ SI DES 3 518' X 20 GA. """rE'A, S:. DS • Iii O.C_ MST 141.... A4.. BR5IDGING • 4 O_C. AS REQ"D BY CODE BASE AND FLT FINISIIIIES. (SEE F144ISH PLAN Aw0 mrromat ELEviv ions. ) (E) FLCO! SLAB r i r • MALL TYPE AS SAMOA ON LEGEND Nam GY. dD. la, ONE SCE ONLY' Al" DAM TO 1 B • • M • • • 4 Ilj • 4 a • t n A 4 7 1 0 0 rP 2 O C m v 0 0 0 0 m 14 u IJ u i rr I�M /2 ' ( c a N_ g ▪ Zr > E CAI 4 I PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 9eia8 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 A/E PROJECT #: 0100688 032Fb 03341/03132 PROHI11110N ON REUSE: THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION C LSDC"). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSOC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC, NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS Of THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSOC. onto] NOTICE; THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990, THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL fORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF T HESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CLSSAT OF CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY, I imUtec brands LIMITED STORE. PLANNING, INC. d /b /a STORE DFSIGN & CONSTRUCTION tar s Larot d Parkway • Cu+urT buts, Ohio 43230 I .. ele :ihol ... 614.415.7000 Fax: 614 415 7349 ht tp ;; wwvw.L ` L:1t� .... rir�i�Irct r r(I (:0r1; ` Os GJ SR CA • ICmOIII col a VrOts A g • 2 ¢ I n • (Ay -4 O 0 F•' O )0 to) � Z n �I O 4< C) co Z O C y m v r 8" z Z Z O C co rn v 0 - m U) m m n mr m 11 O n • • I. ALL LIGHT FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED CEILING SYSTEM. NO.12 GA HANGERS SHALL BE ATTACHED TO THE GRID MEMBERS WITHIN 3" OF EACH CORNER OF EACH FIXTURE. TANDEM FIXTURES MAY UTILIZE COMMON WIRES. LIGHTING FIXTURES WEIGHING LESS THAN 54 POUNDS SHALL HAVE IN ADDITION TWO NO.12 GAGE HANGERS CONNECT FROM THE FIXTURES HOUSING TO THE STRUCTURE ABOVE. THE WIRES MAYBE SLACK. 2. MECHANICAL SERVICES WEIGHING LESS THAN 20 LBS SHALL BE POSITIVELY ATTACHED TO THE CEILING SUSPENSION MAIN RUNNERS OR TO CROSS RUNNERS WITH THE SAME CARRYING CAPACITY AS THE MAIN RUNNERS. SERVICES WEIGHING MORE THAN 20 LEIS BUT LESS THAN 56 LBS IN ADDITION MUST WAVE TWO NO.12 GAGE HANGERS CONNECTED FROM THE TERMINAL OR SERVICE TO THE CEILING SYSTEM HANGERS OR TO THE STRUCTURE ABOVE, THESE MAY BE SLACK. CROSS RUNNER. 2' -O" O.C. DIRECT FIXTURE SUPPORT MAY SLACK MAIN RUNNER • 4' -0" O.C. FIXTURE SUPPORT WITHIN 3" OF EACH CORNER ACOUSTICAL CEILING TILES STRUT (AS REQUIRED BY CODE) SUSPENDED LIGHTING N.T.S. 01SAl23MO M NOT USED NICHE - DISPLAY LIGHT SECTION 55/5' GYPSUM BOARD ON 3 S/8` x 20 GA. METAL FRAMING • 16` O. C_, BRACING TO STRUCTURE AS REQUIRED AUTOMATIC DOOR CLOSURE MTL. 'L' ANGLE FASTEN PRIMARY CARRY CHANNEL TO CROSS CARRY CHANNEL, CONT. AROUND OPENING. FASTEN W/ SHEET MTL. SCREWS VARIES REFER TO RLP B.O. (N) CEILING SELF TAPPING SCREWS CONCEALED PIN HINGE SCREWDRIVER OPERATED CAM LATCH, MOUNTED FLUSH ANGLE MTL. CORNER BEAD CONT. AROUND OPENING. FILL, TAPE AND SAND SMOOTH PAINTED, TO MATCH CEILING FINISH 1 - L ._ '+ J FLUSH ACCESS PANEL, SEE REFLECTED LIGHTING PLAN FOR SIZE AND LOCATION 1,r 111A11 1,1 MI NUM I ACCESS PANEL c NOT USED NOT USED 3•=1P -0' 01SAl23J0 SCALE J H H.O. (N) CEILING OPEN CEILING PREFERRED OR CEILING AS REQUIRED BY CODE NOT REQUIRED FOR GYP ASSEMBLY 6" METAL STUDS 20 GA. • 24" O.G. NOT REQUIRED FOR GYP ASSEMBLY NESTED STUD 4 RUNNER VARIES REFER TO B.O. THRESHOLD VARI 5- R F R T. R I kixos•to ACOUSTICAL PER FINISH LP 7 I /4" SUSPEND CEILING TIL SCHEDULE CONTINUOUS EDG MOULDING CONTINUOUS EDGE MOULD! SUSPENDED ACOUSTICAL CEILING TILE PER FINISH SCHEDULE VARIES REFER TO RLP B.O. (N) CEILING PERIMETER WALL (INN ERE OCCURS REFER TO RLP STRUCTURE STRUCTURE VARI . *. MECII FASTEN PER MFR DETAIL 8 GA HANGER WIRE x+48" OC MTL. I L' ANGLE FASTEN TO W/ CLIP. FASTEN CARRY CI-IAN TO MTL. 'L' ANGLE I*&/ F10 -1 1/2" SHEET MTL. SCREWS VARIES REFER TO RLP 5.0. (N) CEILING 7/8" METAL DRYWALL CHA AT 14" O.C. • RIGHT ANG TO CARRY CHANNEL A TOGETHER W/ MET CLIP OR TIE WIRE 3 -O 01SA0 SHREMSHOCK ARCHITECTS, INC. 6130 S. SUNBURY ROAD SUITE 100 COLUAN ,, ON 43081 614 - 545 -4550 - www.shr.mshock.com W NO N •4 Q. = 0 z., m 0 H W Z , x N Z Lo & . o 4` N W • W M..- h dWW�W W W ►- t Q cir � ON 2 _ 3 J nz Y N t O ■ m O - t o W W g .5,V N z2 o .. 41.. nit % N� °� Z z h R i 0z N Z iz� �r O s .. -0- 0 "► : pyy�y •-.m_....,0 e :Z E! : : i O S N ::;2::;:;2738 4 Nr4,_ tz 0 Z i p o� .- or W o o~ W Z 4 0 K j o- 0 I . O r ZaZ`Oe N ;i0. ZOO O 4 () z - I a.rcXWpjF en I = O .r OY . Qz x 0 n3 C r- z W N q 3W.o4 am 4 - n - ;NEN CEILING AND LIGHTING DETAILS 23 G ov a ;m � 0 7N W 1 ! Z ' n' OKUO-, O, UO L .m . - KU W .WNN W 0 O 0 N S0.[OOZ 2 z U z n W W O { _ � ate O u �'r n 'c o '^o W N O <N 2 r n '� U Ur2� -U Op7Y�WQ� W^, VA�r W W Z O x Q U J = Z =; WO ►mot r-� N- C7 0 UUWWt2 1 W n h UUz =O U OPEN CEILING TRANSITION (A.C.T.) CEILING C PERIMETER (A.C.T.) CELING ASSEMBLY A.C.T. 3 " :1�O" � r 01SAl23F0 01SAl23E0 F E D ATTACH TO (E) STRUCTURE VARIES REFER TO RLP B.O. (N) CEILING SUSPENDED CEILING ASSEMBLY (VARIES) 3 5/8" METAL STUD • 16 "O.C. W/DIAGONAL BRACING • 4' -O" 0.C. METAL CORNER BEAD - TYP. VARIES REFER TO ELEV B.O. SOFFIT (CABINET) SEE FINISH SCHEDULE N VARIES - SEE PLANS 3 CEILING @ SOFFIT (TYP.) CEILING PERIMETER WALL (GYP.) CEIUNG ASSEMBLY GYP. 3 ._ 1 ' -O . o1SAl23CO B h VAR; ES B.O. (E) SrRLiC71.)RE I - ! 2 CARRI'AhIG Ci4AI EL • rb" OC AND 11.4 MO 4 3' OF 1,04.4.5 (SPACE 24" OC FOR FARE RATED CC ' L CT ,) - PROVrDE f' CLR • AEluirrliNG KAL.LS AMID PART111 REF IR TO SPIV:AMA 1CIN IS Fait >0 4 'wAT MNID GORO"ACT ""r"`... GAMINE- - Cam.• P OR .4*,*.ernER V4 RE '7/e" rstra & k .. • R•Gr..~' ANGLE TO C.AIRR"*• M►I.L AND SPACED Ai' 0 SPACE FDIC, IPIIITI►ON 3' OF FIAL .5 AND PROVIDE r` CC.R • ADtiTT1IG IN AL.LS AND PARTMONIS • 1. • • • i II • THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 961 88 SCOPE: RLMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSDC PROJECT #: 00043770 A/E PROJECT #: !ROHI @ITION QH_REM THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED roR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., 0 /B /A LIMITED STORE DESIGN AND CONSTRUCTION ("LSDC"), THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL DE MADE WITHOUT THE WRITTEN AUTHORIIATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. COMM] NOTICE: THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OE THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION Of CONSTRUCTION, BUILDING SEIZURE. AND /OR MONETARY LIAIIILITY, M I i L... D STORE ORE PLANNIN , INC. h /ca SORE DESIGN 8 CONSTRUCTION hrk?E? Limited Parkway • Columbus, Oho 43230 Telephone: 6 4.4 15. / 00 • Fax: 614.4 15. / 349 hits.) 'i wwvv.L.. SI:in(.:.L itl c1H( COUT) 1 i • • • • cs w m to 1 W 14 1 3 v A 310 s 1 1 P ft t mg 04 , s o . 4 idg 8 4 E P1 41 -sh - dp‘' : ;4 ORT 9 1 1 sZD cZ) *1/4N3 1 r 0 0 co to m 0 co m rn n 0 I C z m n Z y i co W 34' m1 (n 70LP0 )* 7* o ]E1)D.. 0 -4 T � 7 6) 3 D N 70 m� C; i> 7 ): PI rn cm 9 a > LN m 71 cW r tri r 92 > RI r m Z 2 rm r Om r N � r _§ D� rn z 0 N r r m 0 " - V 8 c p- r oxi_c 3 w m -<oD A O °oEm tp�r.� 0 N 3g I D .0 mmm_i _ipop io" Om 1'_0 I/8" nrgiq m z; P-(41 040g L r 3 r 3g Z 0 C ca m z O c (I) m v C 0 - n 2 O C cn m 0 C, n co 0 m N Y 0 � �0 co 0 4 di 1 PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: REMODEL /DOWNSIZE P ACKAGE: DESIGN TYPE: ALMON G ENERATION: A LSDI#C PROJECT #: 00043770 A/E PROJECT #: 0100688 032Fb 03341/03132 PRQHIBtIIQN REUSE: THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LITER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNtNO, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC "). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT OF DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT ExCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSOC. ALL ORIOINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. COPYRIGHT NOTICE; THESE DRAWINOS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION Of CONSTRUCTION, BUILDING SEIZURE. AND /OR MONETARY LIABILITY. I i m itec brands LIMITED STORE PLANNING, INC, d /b /a STORE DESIGN & CONSTRUCTION 'tree L..imite1. Parkway • Coitrrnbi.ts. Ohio 4323C: E eltphoi e: 614.415./000 • f- ax. 614 415./349 L_yr)C:.l.irnitt :j 3r ;:3r c:i . or $I Ow 0 CA VI * - '0C-‘z • C m O r Ul 3 I a g O • ' 70 3 • • add o -I n WM Qi DESCIIpT1ON GENERAL CONTRACTOR TO INFORM OWNER IF LAVATORY INCREASES IN SIZE OTHER THAN WHAT IS SHOWN TO MEET HANDICAP REQUIREMENTS. 0 C L_ H LOCAL A AMETER METAL GRAB BARS (REFER TO DETAIL D- 4/A13.1) MUST 3 a 5'--0" HANDICAP TURNING DIAMETER TO BE PROVIDED IN HANDICAP LAVATORIES. 0 0 HEAVY LINE INDICATES EXTENT OF F.R.P. CSF -I], ON WALL: 36" ABOVE TOP OF SERVICE SINK AND 12" (MIN.) BEYOND EACH SIDE OF SINK. CAULK AT F.R.P. /SINK AND SINK/FLOOR WITH WHITE SILICONE CAULK. MOPS INK SZQRAGE SHELVES: GENERAL CONTRACTOR TO FURNISH AND INSTALL (5) 16' DEEP ADJUSTABLE PLYWOOD SHELVES 0 LAVATORY STORAGE SHELVE$: G.C. TO FURNISH AND INSTALL (3) 14" DEEP ADJUSTABLE PLYWOOD SHELVES TO BE 30" LONG WIT1 -I CLIPPED CORNERS. : CLOTHING { -IOOK: GENERAL CONTRACTOR TO PROVIDE AND INSTALL A CLOTHING HOOK MOUNTED AT 44" A.F.F. TO BE ALUMINUM FINISH, NO. SOOD BY BUILDERS BRASS WORKS (OR EQUAL) MOUNTED TO SOLID IN -WALL BLOCKING. Q GLASS MIRROR: 18" X Up" )( 1/4" PLATE GLASS MIRROR (ALL EDGES OF MIRROR TO RECEIVE SLIGHTLY CURVED EDGE 1...4 ITN SMOOTHED OR POLISHED FINISH) W/ TOP 4 BOTTOM "J" CHANNEL (SET MIRROR IN FULL BED OF MASTIC) PROVIDED 4 INSTALLED HY G.C. MOUNT BOTTOM OF MIRROR, AT 40" A.F.F. 4 CENTER ABOVE SINK. 9 GLASS MIRROR: 18" X 36" X 1/4" PLATE GLASS MIRROR (ALL EDGES OF MIRROR TO RECEIVE SLIGHTLY CURVED EDGE WITH SMOOTHED OR POLISHED FINISH) W/ TOP 4 BOTTOM "J" CHANNEL (SET MIRROR IN FULL BED OF MASTIC) PROVIDED 4 INSTALLED BY G.C. CENTER 4 MOUNT ON LAVATORY SIDE OF DOOR WITH TOP/MIRROR P 70" A.F.F. 00 CORNER GUARDS: PREFIN!SHED METAL CORNER GUARDS SUPPLIED BY OWNER AND INSTALLED BY G.C. MOUNT BOTTOM OF GUARD AT 1/2" A.F.F. (OVER BASE). 11 TOILET PAPER HOLDER: 2 3/4 "1-1 X • 1/6 "L CHROME (lb GA. STEEL) SELF LOCKING SINGLE ROLL HOLDER 4 I /2" FROM WALL. ® PAPER TOWEL HOLDER: 13 1/4 "W X 3 "L " X 4 3/4 D WHITE ENAMEL OR METAL KITCHEN ROLL -TYPE HOLDER. 3 FRICTION -TYPE MOP HOLDER: SINGLE AND DOUBLE STRIP - 5 "N X 46 "L STAINLESS STEEL, SATIN FINISH, SPRING LOADED RUBBER CAMS THAT GRIP HANDLES 7/8" TO 1 1 /4" 1N DIAMETER AND HOLD MOP(S) 3 1/4" FROM WALL ('5' 14001(5 INDIVIDUALLY PACKED) FRICTION -TYPE HOSE HOLDERS: MOUNT AT 12" A.F.F. 5 Q SEAT COVER DI�►PEN *ER: VERIFY LOCAL CODE OR ORDINANCE. WATER CLOSET: AMERICAN STANDARD 'CADET' 1$2168.100 (ADA APPROVED) B� 5INK: AMERICAN STANDARD 'DECLYN' *0321 .C26 (ADA APPROVED) FAUCET: AMERICAN STANDARD 'RELAINT' 2385.460 Q A' QP'SINK: 24" X 24' FLOOR MOPSINK W/ FAUCET SET (TO INCLUDE 42" HOSE ALL SY G.C) TOILET ROOM (KEYNOTES o , o '" a L 1. 2. 3_ 4. 5_ 6. 7 a. 0 lo_ I_ Q_ IDS ALL ACCESSIBLE ENTRANCES SHALL BE IDENTIFIED AS REQUIRED AND BE VISIBLE FROM APPROACHING PEDESTRIAN WAYS. OPERATING DEVICES ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE_ LEVER OPERATED MECHANISMS, PUSH -TYPE MECHANISMS, AND U - SHAPED HANDLES ARE ACCEPTABLE DESIGNS. HARDWARE FOR ACCESSIBLE DOOR PASSAGE SHALL BE 1"10U 4TED NO 14 IGl -IER THAN 45" A.F.F. HAND ACTIVATED DOOR OPENING HARDWARE SMALL BE BETWEEN 30" AND 44' A.F_F. MAX. EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBF FOR INTERIOR DOORS_ EACH SIDE OF AN ENTRANCE SHALL BE LEVEL W ITN AN AREA IN THE DIRECTION OF THE DOOR SOLING OF AT LEAST 60' AND A LENGTH OPPOSITE THE DIRECTION OF THE DOOR SWINIG OF 44' AS MEASURED AT RIG.cr ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION. FLOOR OR LANDING SHALL Be NOT MORE MAN 1/2'" FROM THE THRESHOLD OF THE DOORWAY WITH A SLOPE NO GREATER THAN 1.2_ FLOORS TO BE SLIP RESISTANT. IF THE DOOR HAS A CLOSER, To THE SEEP PER OD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN( POSITION OF 70 DEGREES, THE DOOR At 4/-1_ TAKE AT LEAST 3 SECONDS TO MOVE TO A r 3' FROP i THE LATC14, mEA5uRED "rO TIE i..EAD G EDGE OF "T`HE DOOR _ PIE +G 4T OF CLOTH 'VG BOOKS 5 -• 8. wiC r BE GREATER . - 644.1 , 4 AID' FROM' THE F R _ ' 5' RUC 1)RA_ S'"RENIG 44 OF GRAD! BARS, SEATS, FASTENERS, AND MOW!'ING DEVICES SHAL,L_ BE ABLE 'C w = ..STAND 250 ..IBF PO,(r 0t7M,D, BEARING, S+NE/►R, AND TORSION_ GRAB MARS 5I'4A.._ VC " ROTA - E rw"".." ' :.ER F: G.C. TO °'RW" DE >4- ti14..r. BLOCK :NMG FOR A,..._ GRAB BAR ...OIC:Al'i NS_ "A ER CLOSET F._...5.- VALVE S.gAd... BE ..00.A'ED Ow " "'IDE Sr DE OF 0..ET (EXCEPT - APirc ''YF'E) TINE FORCE REUI.iRED TO AC''. VA'*°E — 44E cLuSrA VALVE saA.G.L.L BE 5 LBF =A.aC.ET aNTROLS AND OPERA"?' li G ` ECMANtS (SEE NOr"AT'o 4 =2 ADOL/E) _ SEi.F -CLOSING VAL.vfs TO RVIA IN OIL FM AT ...EAST VO Somas «*O' - WATBt PIPES :AVER i.AVA r`'' SHALL BE SATED OR OTHER2,01SE COVERED. THERE 5•41../.. BE NO Si ARP OR ABRASIVE SURFACES UNDER LAVATORY_ IDIMIKING FOUNT*" 50.4414,4_ CONFAIrr TO REGLAMEMIDITS OF TUE AMERICAN DISABINLY i ES ACT -'2 SEE K HANDICAP CONSTRUCTION NOTES .. ; � SHREIIISHOCK ARCHITECTS, INC. 6130 S. SUNBURY ROAD SUITE 100 .. COLuMBus ON 43081 614 -545 -4550 www.shrsmshock.com m 7 :t!.: UO 7 4 WO 0 n 4 ,0. z zW Ot nOwTz O I..4zr0iw i `r O ..- U z .J W O W SIQiF N r -VIS4y adia0► -J Z WZ iZ v - zu7 0 W „ -' N o O 0ox ..,2a a = � d 1 " S 0. •�, 0 n ~ = Z t0Kj► -O O ► S 0 f,� WO C yd"4fS F.. J l..i =Wpj� i i. o 0 t W W J r S - .31"'11. W e � z °a0 '�? ° c ` ao m a : 69 J * 7 O W Z u acv0� W �W► =<O U � U , W O i W I1 xaac Oa z& O M <.[i�COto d W I 4 i ► .- a�' ca�zc.� „ V7 W 7 a07 �i ( ~ ] 'pr W W z 0 z . ° c i i = .. a— 3 a�i� ; .+o i!,_ vI =� y a i.7 V W W t= a1W i:e _gQ.� >rNarx�m7l r UUOO]:.7 r`. "6/C3 S NOP ASS H.C. PRIVATE TOILET/ JAN. CLOSET ILL Fe) N M Pe) O M 0 REFER TO SPECIFICATIONS FOR FINISHES 5/8" TNK_ GYP. BD. TERPROOF MEMBRANE UNDER SHEET VINYL AND UP WALL 6 BASE DETAIL @ CERAMIC TILE F0 E WAINSCOT ELEVATION (F.R.P. OR SIM.) 54' (MIN.) 42. (`TIN). WAINSCOT ELEVATION (CERAMIC TILE) D TYPICAL TOILET ROOM PLAN REEFER TO DOOR SCHEDL.L.F FOR HARDP4ARE RED. t REMEPCPS THIS PLAN IS FOR REFERENCE ONLY /WOW *LAMS AIRS Palle FICOM RE AND POWS BAR lumerntomiconk Pot EXACT Mlo / Sal. GONFIGUINAT1014. AND DOOR SOOMMUS - 141,901 -1v TaE O1EA131CO 1/2•2r -O" O/EA138O S r S IGNAGE NOTES: ON FL 4Sit:OHOpo 32" x 48" MINIMUM I CLEAR FLOOR SPA CENTERED UNDER PROVIDE DRINKING FOUNTAIN QNLY IF REQUIRED BY CODE. IF THE DRINKING FOUNTAIN IS LOCATED IN THE PATH OF TRAVEL, A TEXTURED AREA 1' -O" AROUND THE FOUNTAIN, CLEARLY IDENTIFIABLE BY THE BLIND 15 REQUIRED. BUBBLER IS TO BE ACTIVATED BY A HANDICAP PUSH BAR ON FRONT FACE OF UNIT. HI /LO DRINKING FOUNTAIN I. LETTERS AND NUMBERS SHALL BE RAISED 1/32 ", UPPER CASE, SANS SERIF OR SIMPLE SERIF TYPE AND SHALL SE ACCOMPAN 1 ED W I TI4 GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE AT LEAST 5/8" 1-1IGI.1, BUT NO HIGHER THAN 2 ". PICTOGRAMS SHALL BE ACCOMPANIED BY THE EQU IVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAMS. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BEE 6' MIN. IN HEIGHT. 2. WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, SIGNS SHALL HE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR. WHERE TI -IER IS NO WALL SPACE TO THE LATCH SIDE OF THE DOOR, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL. MOUNTING HEIGHT SHALL BE 60" A.F.F. TO THE CENTERLINE OF THE SIGN. MOUNTING LOCATION FOR SUCH SIGNAGE SHALL BE SO THAT A PERSON MAY APPROACI1 WITHIN 3" OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. 3 TO LET ROOM DOOR SYMBOL SHALL BE IN CONTRASTING COLOR. '1► "► r- z z F.R.P. 4 SCREEN MOLDING ) SIDES FROM FINISHED TO 46" A.F.F. I -LO DRINKING FOUNTAIN ADD F.R.P. 4 SCREEN MOLDING ON (3) SI DES FROM FINISHED FLOOR TO 48" A. F.F. SINGLE DRINKING FOUNTAIN N.Y.1L BATHROOM SIGNAGE WALL SIGNAGE III GENERIC ELEVATION As NOT= IAN OR MOUNTED SIGNAGE 0:L4, GRAB MIN. Inns sew DETAL AT WALL .0 0 I In Mat AND MOMMAIMLIMMOk I9A1X_ MIS 00111 riMllls a� .t MOT NOME I 101/11 ME 10 WE OD SOW -. a aeons ON ar I - P LL MrMii v 10 115. /III AID 10 rli.00 WAIN A aF W 11111011 S'D TO J STUD wir awe 0•1211110 �► Arlrwarws awMl _L E CEI�C110 _ A IN s.� TYPICAL TOILET ROOM ELEVATIONS I N.T.S. I OIDA131J0 l IIESTWOORIMI 01EA 1131H0 Kr.s. H ■111aA1E ON COMM M,L EDT ■I11s /MIS MOO MIS SIM - MD BMW CS sIIE ,s wuarwo 1011011 SEM P -a1 I 4' -O" A.F.F. T .O. WAINSCOT METAL TRIM I NC -1 PROVIDE CONTINUOUS COVE STRIP METAL TRIM 5/6" TNK. GYP. BD. PROVIDE CONTINUOUS COVE STRIP FC -4 SWEET VINYL WATERPROOF MEMBRANE UNDER SHEET VINYL AND UP WALL 6" BASE DETAIL @VINYL /V.C.T. o" A.F.F. 'PST 001110010 M 110 aIR E 111101.• 01wr1101► VI OBE IS rills UMW Me OIN1100 1111110.01111. MONK 011 1111511111 OF VII VOW 1I0 MEM - is AIC�"INM11E 0110111111LS amL I�wr - $ ua MI UMW 4001A10111 SIM _ slNrr TIM r WAINSCOT DASHED LINE INDICATES TOP OF WALL TILE_ USE TILE ONLY IF REQUIRED BY LOCAL BUILDING AUTH(0)RITIES LFLusi4 1 4ANDLE r"+1J5'r BE ON " S+1DE OF MIA TER C4.05ET GENERIC ELEVATION rKAM P -q If FC -6 f DULL NOSE St 1 12' * 42 (*'h_) C 4- I _ rr -1/' TO Tao cF TIIR.ET SEAT I fr :1'_o. I 01SA131FO GENERIC ELEVATION rem w S 4 • • S an C .11 o an Z C) 0 m n z r Z 0 C rn m I i I I_ 5I-4" n 5'-10 I/2" TO TOP OF GYPSUM BOARD PARTITION 7-2" VERIFY 9 N n - 1) --> zi D i: O m r X PE • ni O 2 n rT1 f1 m � i rn N ?:1 in =1. gaLimi 3.0 PI xi 3. 9 A 4 1 E`1 r it t 1 V PROJECT INFORMATION: THE LIMITED SOUTHCENTER 033 SOUTHCENTER MALL SEATTLE, WA 9818e SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 A/E PROJECT #: 0100688 032Fb 03341/03132 PROHIBITION QlLRLUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS (PRO"LSHIDC•). BITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY Or LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION or THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSOC. THESE DRAWINGS INII AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, IT U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES. WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION. UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION OT CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY. I i b rC I L.I 4.... # %FTED STORE PLANNING, INC. d1b /a. STORE DESIGN IGN & CONSTRUCTION Three Limited Parkway • CO UMbuS. Ohio 43230 .t eIt,r)t}nn1 : 614.415./000 , Fax: 614 41:2:1349 I~dt[_) • • WWW E.. ` 1::31FC = ; ,nitec.IBrar ds.c om * cab cl u) co vs • r . if C m 17 1 4°1" " a cm iO 0 0 —C = 3 O-1 Els v' p 1� P _ \ \ \ / / / / / / 0 c r \ i \ \ \\ \ / V // / / / Z m ID D r � 3 7 of -9 I': rO - t 33 -ii - � r- rr� N D m , )'-.0° W-0" > N s, ". % 4 • • S an C .11 o an Z C) 0 m n z r Z 0 C rn m I i I I_ 5I-4" n 5'-10 I/2" TO TOP OF GYPSUM BOARD PARTITION 7-2" VERIFY 9 N n - 1) --> zi D i: O m r X PE • ni O 2 n rT1 f1 m � i rn N ?:1 in =1. gaLimi 3.0 PI xi 3. 9 A 4 1 E`1 r it t 1 V PROJECT INFORMATION: THE LIMITED SOUTHCENTER 033 SOUTHCENTER MALL SEATTLE, WA 9818e SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 A/E PROJECT #: 0100688 032Fb 03341/03132 PROHIBITION QlLRLUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS (PRO"LSHIDC•). BITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY Or LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION or THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSOC. THESE DRAWINGS INII AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, IT U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES. WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION. UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION OT CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY. I i b rC I L.I 4.... # %FTED STORE PLANNING, INC. d1b /a. STORE DESIGN IGN & CONSTRUCTION Three Limited Parkway • CO UMbuS. Ohio 43230 .t eIt,r)t}nn1 : 614.415./000 , Fax: 614 41:2:1349 I~dt[_) • • WWW E.. ` 1::31FC = ; ,nitec.IBrar ds.c om * cab cl u) co vs • r . if C m 17 1 4°1" " a cm iO 0 0 —C = 3 O-1 Els v' p 9 a a IF a 4 • a r 0 v t 17 Iiii il 1 fi 1 1 : iti A L. H 4" CF i i 5 % JA g 2 I/2" -� 0 Un •1 C) 0 m . n z r 11 —�1 Z 0 co O m n O Z H 4 6' -0" 4' -10 1/2" 1 1/2" rn r rn O p -I_ 0 z (ft r rn 70 zZ m r ApOr m -1 D- 2 t rn 0 rn 0 rn rn 2 0 z UT IJ 3 z N I - Ott 4 - 0 " DOto= D11ro D d� �P� Z r rn D t 4"Al mo IN - Al 2 g 0 ( 0 rn 0 c r 2 D-13r �, ! ooXZ �D7� i P,O70v - 0 70 Ft" i - t,o r <- fq 201 rr R 70A I 3 ■ 1 AXX w 2 m i N 70 p r mrn l7 r 7D m oo ZZmy r a-i -4 2 t m rn 0 z r z ( 3 %z) Nsz 2 t_ g tt 4' -0" m r q -' z k b. ; N lb. EQUAL. PROJECT INFORMATION: THE LIMITED SOUTHCENTER 833 SOUTHCENTER MALL SEATTLE, WA 88188 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 A/E PROJECT #: 0100688 032Fb 03341/03132 PROHIBITION ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE GATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY ( LIMITED "LSDC.). STORE PLANNING, INC., 12/9/A LAMED STORE DESIGN AND CONSTRUCTION THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSOC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. CQPYHJGti.T NM; THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION Of CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY, Limited bran's LIMITED STORE PL.A NIfiI' , !NC. d/b/a STORE DESIGN 4. CONSTRUCTION Three t.imited Parkway Columbus, Ohio 43230 t telephone. 614.415./000 • Fax: 614 415./349 1�tt ; ;'WWW.[..SiAIC t EnutedBrr ldS.GOr7I co 1 ' -0 .1 2 ' - q 11 II { CO AM I A rno q rn rn t1 r z 3 z • s a • • s y an 0 z r A 0 I W gig r A O f z F r r 0 wri 1 I 0 0 IlI I 11 0 0 0 v m - W 0 r n O It 1 1 - I BASE N 1 • * 0 —� m 3q -11 qg§ " 41) 6 -2 1 N jp D- F' r61° to at n � • 1/2 1/4 MIRROR I 1/2" 4c3 czt \tb ‘4*4' r r O v m 0 0 /1 I v m C i z C) 0 0 W 0 1 v rn r r N 4 - 10 1/2" A VI 0 LAI S t PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: _ LSD&C PROJECT #: 00043770 A/E PROJECT #: 0100688 032Fb 03341/03132 PROHIBITION ON REUSE; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF. ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., D /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC, NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION Of THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. capYRIGHT _ NOTICE; THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION Of SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY. limited brands L T IW STORF PLANNING, INC. d /b /a STORE DESIGN 8 CONSTRUCTION r ,re;'e L.ini ted Parkway Columbus, Ohio 43236 1 N1ephone: 614,415,1000 . Fax, 614 4 15. 11340 http://www.t...SDne I. grnitecit :r Erck z c on, 3 Ic ' om * m sH M usg 3 g • g. g A A W '� O Cs 0 xi 0 In P 1 E 0 HANGING ®HANGING(FIXED) FOLDED /LTA. FOLDEDIFIXED) NLT.8. THESE DETAILS ARE FOR REFERENCE ONLY REFER TO SPECIFICATIONS AND MANUFACTURER GUIDELINES FOR INSTALLATION. WALL STANDARDS MOVABLE STORAGE (FOLDED OR HANGING) FIXED STORAGE (FOLDED OR HANGING) 1/4•if -0' M F in a U 4 N to z U 4 In In 0 PLANNING GUIDE N F 3' -2" 3' -O" OR 5' - \1 - 4" MOBILE SHELVING DETAILS G.C. 15 TO LOCATE (2) 16 GA. STUDS to 24" O.C. CENTERED BE4 -IIND W.C. FOR ATTAC4 -IING WALL STANDARDS. ADD ADDITIONAL WALL STUDS AS Q NEEDED TO ENSURE ADEQUATE BLOCKING FOR WALL STANDARDS IN SINK RM. 4 OFFICE. 3. USI AND GL BOTTOM 4. REFER TO ANCHOR TO LOCATION WITH GENERAL NOTE: 1. ORGANIZER 15 TO BE CONSTRUCTED IN FIELD BY G.G. USING 3/4" A.C. FIR PLYWOOD AND SCREWS. .C. TO INSTALL WOOD OR PLASTIC SCREEN LDING ON EXPOSED END GRAIN EDGES. LEFT -OVER CARPET SCRAPS, G.G. 15 TO CUT E PIECES IN ALL BIN BOTTOMS AND TO UNIT. STRUCTION PLAN FOR LOCATION. L AFTER CONFIRMING FINAL NER'S REP. EEN DING ON ALL EXPOSED EDGES 2 X 4 WOOD STUD PLATFORM SYB. (DI DESCRIPTION OMIT OMIT 14" DEEP SHELF 314 PLYWOOD SHELVES WIT4 -I V X YI SCREEN MOULDING GLUED 4 NAILED ON ALL EXPOSED EDGES. PLYWOOD TO BE TYPE 'ACC' INTERIOR GRADE MIN. FINISH BOTH SI DES. 040LO BACK EDGE OF SHELF IV OFF FACE OF STANDARD BEFORE SECURING TO CLIPS - TYPICAL) SHELF BRACKETS AND HOLD -DOWN CLIPS OMIT OMIT WALL STANDARDS - G.C. TO CUT TO LENGTH t INSTALL TO SOLID IN -WALL BLOCKING OR FURRING. REFER TO CONSTRUCTION PLAN FOR CORRECT SPACING. OMIT OMIT OMIT 03 OMIT OMIT OMIT THE >A OF BASES !N A *1ODt)LE_ T4 MAX. * OF BASES PER MODULE IS b 7 OR MORE 1" I X3 i LE IN A BAY WILL REQUIRE 2 AISLE t 2 SETS OF STOPS. TI.4E DISTANCE BETWEEN S0-+ELV3NG t 6-.E DESK S S' -0' NOT USED ..•E Si4ELAI NG A SL.E "'".:5' BE A' A "'IP, OF 3 -O" .`© "EE - ADA CODES_ USE "r4E SINGLE FACE F; XED S 4ELVI'rVIG AGAI Ni5' ./. 14I IN TIRE movABL.E BASE 5r5rEr r USE T;4E DaueLE FACE FIXED SkELYING BETAEEN MODULES OF MOVABLE SHELVING, OR AT TUE ENDS M4 4ERE "MERE ARE NO WALLS. 0 P ALIGN 3' -0' SPACE BETWEEN T11-+E r"' 0VA8LE 5'rSrTE"'1' AND TI.IE NALJL, cowrim, OR OUTERMOST OBISTRUCTCIPC FOR SE SMC APPLICATIONS ADD MITI -TIP AND ALL ON 5' -0' 1tJLTI PL.E srs AMC?✓+OR 4" EIET1NEV4 iptALL._ "Nri -TIP DEVICE TO BE USED F114 ALL 3 AMID 4 SETSMIIC ZONES_ 0 NOT USED SHELVING AND HANGROD KEYNOTES P!! r11411- i ll; 1 11 A!! HARDWARE STORAGE BIN SHELVING DETAIL AS NOTED O1DA141JO N.T.S. O1DA141HO 1, ON 7 �- 24' (SEE P,_AlN) (-- rP jNLESS _+ PUO ED 0 4 -1ER/A SE) TYPICAL GYP. BO. WALLS 1$ GYP. BD NOTE: PROCEDURES FOR LAYOUT OF TUE STANDARDS !Nf - n-+E NON - SALES w►S CI`+ANiGE:D _ P..EASE REVIE04 TwE CAMERAL. NOTES AND DETAJ LS CLOSE?'" . G.C. TO CALL T' 4E LSP PROJECT TANAGER p4/ ANY QJES 4S OR DESCREPENCJES. G. C. NOT TO START FROM CENTER OF MALL AND b4ORK OUT 24" (SEE PLAN) 241 c 2 hYC"rID UW".ESIg ) � I 1, HAWagnallftriffaillail SS GENERAL CONTRACTOR TO INSTALL 1 X 4 SURFACE MOUNTED FIRE RETARDANT TREATED r4OOD FURRING FOR STANDARDS OVER S' ' GYPSUM 80ARD_ r* ir- 5Ja• GYPSUM BOARD ON METAL FRAMING WALLS •uRFAC.E MOUNTED STANDARDS SUPPLIED Err OMi R AND INSTALLED BT SAL CONTRACTOR USING 1/7 872 SCREAS_ GENERAL CONTRACTOR TO iNLSTALl. ]i X 4 SURFACE ALE MOLAIOMMD FIRE RETAiRDIAIMIT TREATED r400112 Pummeg, Fat STANDARDS_ I" 2" bELDED (PORE !}a WERE 441DKJITED ON PLAN, PORE PlES0 Is mar REQUIRIED ON FREESTANDING HALLS, E'l1JT IS REWIRED ON MALLS MOIMMW OS SEPERATE ROOMS - *TTA04 TO STUD* w LAT111 =MEWS BEFORE INSTALL/4G stuyeliNG STRIPS. 3 SO" . III GA. FACTORY PRIMED METAL STUDS • 7-0 O C w CJDIfT11Mu11s TQ t idDTTO 4 T'RA= AND moimeariTAIL. lRtAC NG J H UPON COMPLETION OF PROJECT GENERAL CONTRACTOR MUST RUN A NEW BLUEPRINT SET FOR THE COMPLETED STORE DRAWINGS (ARCHITECTURAL, MECHANICAL 4 ELECTRICAL) AND PLACE BLUEPRINTS INTO THE PLAN TUBE HOLDER. 1/4" DIAMETER THRU BOLT W/ TOGGLE (TYP. OF 2) PAN HEAD SCREWS TO SECURE STRAP 5/4" x 2" POPLAR PLYWOOD TRIM SCREWED TO 2 x 4 METAL STRAP (TYP. OF 2) in LOOSE PVC TOP CAP 48" A.F.F LABEL m EXTENT OF WOOD HOLDER PVC BOTTOM CAP GLUED IN PLACE TUBE ELEVATION GYP. BD. SECTION THRU TUBE G.C. MUST PROVIDE AND ATTACH A LABEL (WITH CLEAR TAPE) STATING: THIS TUBE CONTAINS STORE DRAWINGS AND 15 NOT TO BE REMOVED WITHOUT THE CONSENT OF THE STORE MANAGER. THANK YOU. hit2IL ENTIRE ASSEMBLY IS CONSTRUCTED BY GENERAL CONTRACTOR IN FIELD. DRAWING TUBE DETAIL N.T.S. 0IDA14S =O F NOT USED E NOTE_ COM PLETE HA SUPPLIED AND I REFER TO REFLECTED LIGI -ITING PLAN CONTINUE TOP PIPE (ONLY) TO WALL AT END AND SECURE (TO HELP STABILIZE SYSTEM) 3/6" GALVANIZED STEE ALL - THREAD ROD 6' -6" A.F.F. 7/16" DIA. DRILLED MOLE FOR ROD ROD SYSTEM TALLED BY G.G. .o STRUCTURE - ACTUAL FLAT HEX - S BRACE ANGLES ) ( FLAT WASHER AND I HEX -NUT SEE DETAIL ABOVE " `1 111•11111111. /..111141.0. S DETERMINE DITIONS IN FEILD. ER AND (2) EL ANGLE BY G.G. - G.G. RESPONSIBLE TO ESTABLISH THE REQUIRED SIZE OF ANGLE BASED UPON ACTUAL SPAN. SECURE TO STRUCTURE. STEEL 'BRACE' ANGLE EACH SIDE OF HANGER BY G.G. TO PREVENT ROD MOVEMENT OP THE CLG. G.C. IS RESPONSIBLE TO ESTABLISH THE REQUIRED SIZE BASED UPON ACUTAL SPAN - SEE DTL. ABOVE LAY -IN CEILING (AS REQUIRED, REFER TO RCP) 1 1/4" O.D. GALVANIZED STEEL IPE IA ITN FLAT WASHER t (1) NUT TOP AND FLAT WASHER 4 (2) ON BOTTOM (TYPICAL). T WASHER AND (I ) NUT. AND (2) OF P.Y.C. END CAP - USE SILICONE TO SECURE IN PLACE 2" Arm Elm OETA�_ NU H FLAT WASH HEX NUTS G.G. TO FILE EN THREADED ROD T REMOVE ALL BURRS (TYPICAL) "M E ._.. V7 z a SHREMSHOCK ARCHITECTS, INC. 6130 S. SU NBURY ROAD SUITE 108 �. W,.�:,►... �_ COLUMBUS 014 43081 614- 545 -4550 www.shremshock.com 6923 REGISTERED ARCHITECT CIS D S. S STATE or - 0 Li 3 ^ __ z 7 a w n r- C -- 'mmi :::: 3 0 i - n m ' :1 ' (a) 2 t2" __I . ti 0 0 . .- U „ V W i0 t 2 2 N N V 7 ;Y1 O ' W x Z~ J O W 2 OO z o 00 W °3„ Q6. CJ ' zp jt SO ; 4 W .1 Z 2U7 ► -�AZN� z U Va. 0- as a W W iO W M~ W W U Z,ZN,41r-Q =H Z�(� . _ Q m OOW=dW 2'pW� -y! � YP2=p= c tt POtt7 ~O p t 2� ,y.KY"�\ Ws ~y1W Wz O[ O S =2�WO �OOF3 C►- oUs d x rx O W.,�O A 2 `.. � W W ��z �_ � oiWr. uo� Q.,, �s��q� W Q� ~WO �'tV.i( W WQ W J � WF =Z .W[w�- � 5, t OQ]I - ,t HW„N 72 �'' O .' O�WUU Y�Iq� "..�OS�`W zOOZ z O'/' .. O� „3 O 0. W_W3 yW 72r ��O it.70{p,� WOV4 VtCx! WOa VW1/!t()Z �' �_�pON= U > O W U G r„ W 0 K di =WOpj� l Cir Z'- U 2 Z 23i.CN� Z� tJ -a "t` =r •( � .17WN Cf 0- „OaW �OG�4 „ �~ �4 Z � p O M = O Z= V „ u 0 a 1/7 _Wti Vb W Zr' W ~ O �O * S y 7) ) X J'7 17 co E • DIM & OESIGINED u-'- SY: CIIIIICICED Sr: W Q Q N Z n iji 0N. CI J 0 Q 0 W 0 limn J J ■ cr i OD 0 2 F" W 4 W ii Zia ca �W .c W; 5 W cw cw imal Q 'n t O V)o CA La co 2 V1 VII O . REVISIONS: W a6M3 # Irk 01.,.,.... s 7r- I U /''3 b SF NOP i STOCKROOM SHELVING DETAILS IIIINSINC I A14.1 SUSPENDED HANGROD SYSTEM N.T.S. O1SA141CO 1) 0 1/e NOT USED VARIES O SHELVING OFIFICEMrA TOINT F w a - it a !p 0 0 0' r _ c O, 4 1r- r.11 REM TO REFLECTED UOITI4G PLAN T I x 6(515) GopeTIIAJOU5 HORIZONTAL F.R_T hIQOD FURRING STRIPS BY G.C. SPACE FURRING STRIPS TO CORRESPOND TO TOP 2 SCREW HOLES AT THE TOP OF EACi 4 STANDARD and EVERY OTHER HOLE IN THE BALANCE OF VERT. STANDARDS. SHELVING iTOCKNo0M NOTE: PoitocEDuREs FOR LA`rovr OF "rwE 5' ANQARDS =N TV+iE NON- SALES MAS 4 CmANGIED_ PLEASE REV' 13211 THE GENERAL NOTES AND DETAI CLOSELY. G.C. TO CALL TIIIE LSP PROJECT MANAGER w ANY GuEsTuoNls aR far To sTAPer _ OF KAU. AND NOW I GENERAL. NOTES: I. STANDARDS SHOULD BE LAID OUT FROM ThE LEFT SIDE OF EACH WALL (WHEN FACING THE WALL)_ 2_ THE FIRST STANDARD SUM L.D BE I' OFF THE LEFT Si DE/EDGE OF THE WALL AND THE REST OF THE STANDARDS SHOULD FALL 24' O.C 3_ G.C. ' O miSTAL4. Ti4E STANDARDS hl/ ThE PRE - DRILLED HOLE AT *TUE 1 "OP OF THE rrALL 4 G.C. TO INS FLAMING STRIPS mA:..,_ •O Ti4E S'T'OCK AREA OF TUE NON- SALES (" Th.+E LOCA"r1ONi OF "'WE MANGER ves Er4) 5 F'.rRRptiG S* RIPS TO BE 6&444D PRE - ,'JQ h..4 6 4 4 ThE STA IDARL715_ AS ' CAWED (PLEASE NOTE T•Al. TOP OF ThE S ANlDARD :" XJST DE SCANNED Forro TwE TOP FURRING, STRIP ) 6 TWE 7"AJOIRET" OF '''►+E SiEL1l"ES PDR TWE IOM - SALES AREA 514 OULD ?MEASURE 4 7/B' Ntit LENGTw AND Ili" 014 17EP'T'f+ TwERE 45 MO PM ERROR DUE TO TIE FUNCTIIGNi Or Tires 5T NON -SALES HANGRODS SHELVES St COUNTERTOPS B I. ier lab • Ar 6 f i 4 4 • 4 a s THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSDC PROJECT #: 000437 70 A/E PROJECT #: THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PLANNING, INC., 0 /B /A LIMITED STORE DESIGN AND CONSTRUCTION ( "LSDC"). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT Of DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSDC UPON COMPLETION Of THEIR INTENDED USE, UNLESS OTHERWISE AGREED BY THE LSDC. GOPYEIGIiL NOTICE; THESE DRAWINOS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION Of SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY. LIMITED STORE PLANNING, INC. d /b /a STORE DESIGN N CONSTRUCTION f hree Lurited Parkway Colo nbus. Oho 43230 Telephone. 614.411.i.1000 • Fax: 614.415_7349 hItry __ SI riC L ;rn tedt3rard on) i t s • 4 r A 0 n 0 y 3 -4 1/4" 2 3/4" Pilit6. WO, S w 1 , EIV0._.• A/Alb - -■,,, m # cp ii.) 1 7 1/2" T _ W . CD m 1 G1 \ N I t _ t + 3' -6" { ' -fin 1 2'-9 1/2" 9 N, 1/2" PROJECT INFORMATION: THE LIMITED SOUTHCENTER 833 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: REMODEL /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: ! LSD&C PROJECT #: 00043770 A/E PROJECT #: 0100688 032Fb 03341/03132 Peril B1IIDN ON REUSE: TNESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF. ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY LIMITED STORE PIANNINO, INC., D /O /A LIMITED STORE OESION AND CONSTRUCTION ( "LSDC'). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO LSOC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AOREED BY THE LSD:. QTRIGHT NOTICE; THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK' UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1990; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE PROTECTION INCLUDES, WITHOUT LIMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS Of THE DESIGN. UNDER SUCH PROTECTION. UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION 01 CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY LIABILITY, Limited LIMITED STORE PLANNING, d /h /a STORE DESIGN 8 CONSTRUCTION three I.. rnited Parkway • Columbus ()tltl: 43230 I_etr: ptio wE 614 415./000 V'a.x 614 41:)./349 t�tt www.L. `aL)tI .. L. iir iiedE3t antis.c;ot 1 i 1 m an m w 0 M 1 1 rn an m 0 1 1 iM zz zz rn3 v 3 ; 'N7° a r ' xxm Tb rN Fa 70 Fa 70 Dorn › r T 1 - oho v - oho 3 - 6 ' ` -0 1/5" W r 11 3/4" ' -10 3/8 " 7/6" J 0 w Y ' -10 1/16" 2'-O" 3 -0 1/6" 3 - 9 4 1/ 16 " 3'-5 7/6" J 3' -2 5/16" Y w T� n L T2 a 1 x co ! TABLE OF CONTENTS DIVISION 0: CONDITIONS OF THE CONTRACT 00700 GENERAL CONDITIONS (AIA A201 -1997) 00600 SUPPLEMENTARY CONDITIONS DIVISION I: GENERAL REQUIREMENTS 01100 SUMMARY OF WORK 01300 ADMINISTRATIVE REQUIREMENTS 01400 QUALITY REQUIREMENTS 01500 TEMPORARY FACILITIES AND CONTROLS 01400 PRODUCT REQUIREMENTS 01630 SUBSTITUTIONS AND PRODUCT OPTIONS 01700 EXECUTION REQUIREMENTS 01735 SELECTIVE DEMOLITION 01800 SYSTEMS DEMONSTRATION DIVISION 2: SITE CONSTRUCTION (NOT USED) DIVISION 3: CONCRETE 03540 CEMENT ITiOUS UNDERLAYMENT DIVISION 4: MASONRY 04850 STONE ASSEMBLIES DIVISION 5: METALS 05500 METAL FABRICATIONS 05700 ORNAMENTAL METALS DIVISION 6: WOOD AND PLASTICS 06105 MI SCE LLANEOU5 ROUGH CARPENTRY 06200 FINISH CARPENTRY 06400 ARCHITECTURAL WOODWORK DIVISION 7: THERMAL AND MOISTURE PROTECTION 07210 BUILDING INSULATION 07560 ROOF REPAIRS 07600 FLASHING AND SWEET METAL 07610 PATCHING EXISTING FIREPROOFING 07640 FIRE STOPPING 07900 JOINT SEALERS DIVISION 6: DOORS AND WINDOWS 06110 STEEL DOORS AND FRAMES 06210 WOOD DOORS 08310 ACCESS DOORS AND PANELS 06410 ALUMINUM FRAMED STOREFRONTS 06700 HARDWARE 06800 GLAZING 06630 FRAMELESS MI RRORS DIVISION 9: FINISHES 09260 GYPSUM BOARD ASSEMBLIES 09300 TILE 09510 ACOUSTICAL CEILINGS 0%40 WOOD STRIP FLOORING 09650 RESILIENT TILE FLOORING 09655 RESILIENT SHEET F 09680 CARPET 09720 VINYL WALL COVERING 09710 PREFINISWED FIBERGLASS WALL PANELS 09900 PAINTS AND COATINGS DIVISION 10: SPECIALTIES 10160 METALTOILET COMPARTMENTS 10260 CORNER GUARDS 10500 LOCKERS 10536 AWNINGS 10660 COMPACT MOBILE STORAGE UNITS 10610 TOILET ACCESSORIES DIVISION II: EQUIPMENT (NOT USED) DIVISION 12: FURNISHINGS (NOT USED) DIVISION 13: SPECIAL CONSTRUCTION (NOT USED) DIVISION 14: CONVEYING SYSTEMS (NOT USED) DIVISION 15: MECHANICAL (REFER TO MECHANICAL DRAWINGS) DIVISION 16: ELECTRICAL (REFER TO ELECTRICAL DRAWINGS) DIVISION 0: CONDITIONS OF TWE CONTRACT SECTION 00700 - GENERAL CON71TION5 A_ GENERAL CONDIT 40IS= • E GENERAL CCNC0TIONS OF THE CONTRACT FOR C.ONSTRUCTCN, AiA RICA r A CI 3 EDi'T`CN, 15 A PART OF THINS CONTRACT, AND SHALL GOVERN +'rG1RK 1. A CLOP ' Nei+.. BE MADE *VA ,..ABLE H1' ARGOTIC' JPON T_ SPEC IOM 00e00 SILP - AIR" C le r A cor - +DAIS ANi ; R.E, R.'5r GENERAL CONDr SUPPL YINTAR's' 0 - O NC D' '1/ S401 - GENERAL REG. ARE IEICS COCA" INFORM* T OM PIECES6ARy =OR C.0"wv-r OF EVER"' PAR CF PROJECT _ B v SOr ' . rtERE PROst SONS '.F GINERAL CL OOO6 RELATE 'O PROJECT A L r 415 Tf..04 OR POW -RELA _E: RE ' 5 L nE carritAcr, 'vow PARR Aid E °APoe h DFVSi1 C. StRIC0041U COWPRAC'OR ACREES "0 ow SueCOiT'RAC"ralit5 AND FA'IERA . S APP 9;5 -ars OF GENERAL ND suPPLErBrairr COt07 016, IirCL�E>'I�G ARBInTA - Or D IiSURANMCE AS k B" OMOIIER E DEPw -7 oN6 L, Aug REWIRES Pere % ACT CM LT' OMM R AS roes TE3a14 SUIRL AS �► V'e C �i�. ' D STW �/ ( WORM , CT®, , AC A A SAT SFA/C' M r _ 2. R SPPL'' A OC DE.MER T Q PROJECT, UNLESS OTWER NLSE rSTATED IN taRFATER or 3 insr Y..,.. cPEIRAricris AT Waal r, FRO1 IN PECT1I K AND TQ IDI :1 °LACE, RFAor FOR Let 4 IRMCN E FURNISi+ AND tNSTA4.I.. co'R'LErE III ND REAM FOR INTENDED USE, MISS Or STATED MI MATER GE'1' DIVISION ONE: GENERAL REQUIREMENTS SECTION 01100 - SUMMARY OF WORK A. SCOPE: PROJECT CONSISTS OF CONSTRUCTION OF THE LIMITED STORE AS INDICATED IN CONTRACT DOCUMENTS. 1 . ITEMS NOTED 'NIL' (NOT IN CONTRACT) WILL BE FURNISHED AND INSTALLED BY OWNER OR UNDER SEPARATE CONTRACT. 2. HAZARDOUS MATERIALS: NOT IN CONTRACT; OWNER WILL PROVIDE FOR HANDLING OF HAZARDOUS MATERIALS UNDER SEPARATE CONTRACT PRIOR TO THIS PROJECT. IF HAZARDOUS MATERIALS ARE SUSPECTED, NOTIFY OWNER IMMEDIATELY. B. WORK SEQUENCE: COORDINATE CONSTRUCTION SCHEDULE, OPERATIONS AND USE OF PREMISES WITH BUILDING MANAGEMENT. C. CONTRACTOR USE OF PREMISES: LIMIT TO AREAS INDICATED ON DRAWINGS AND AS SPECIFIED; LIMIT ACCESS AS DIRECTED BY OWNER. D. LINES AND LEVELS ENGINEERING: ESTABLISH LINES AND LEVELS BY USE OF RECOGNIZED ENGINEERING PRACTICES. LOCATE AND PROTECT CONTROL AND REFERENCE POINTS. E. REGULATORY REQU IREMENTS: PROJECT HAS BEEN DESIGNED IN ACCORDANCE WITH APPLICABLE CODES. COMPLY WITH CODE REQUIREMENTS FOR CONSTRUCTION. INFORM ARCHITECT OF DISCREPANCIES OBSERVED OR NOTED BY OTHERS. F. STANDARDS: COMPLY WITH STANDARDS REFERENCED EXCEPT WHERE MORE RIGID REQUIREMENTS ARE REQUIRED BY CODE. DATE OF STANDARD IS THAT IN EFFECT AS OF DATE DOCUMENTS ARE ISSUED, EXCEPT WHEN SPECIFIC DATE IS SPECIFIED. G. OWNER FURNISHED, CONTRACTOR INSTALLED ITEMS: OWNER WILL ARRANGE FOR AND PAY FOR PRODUCT AS INDICATED ON DRAWINGS TO BE DELIVERED TO PROJECT SITE FOR CONTRACTOR INSTALLATION. 1. CONTRACTOR SHALL INSPECT, RECEIVE, UNLOAD, STORE, INSTALL AND FINISH AS DIRECTED. SECTION 01300 - ADMINISTRATIVE REQUIREMENTS A. PROCEDURES: CONTRACTOR SHALL REVIEW AND APPROVE SUBMITTALS PRIOR TO SUBMITTING TO OWNER'S PROJECT MANAGER; INFORM OWNER'S PROJECT MANAGER I WRITING AT TIME OF SUBMISSION OF ANY PROPOSED DEVIATION FROM CONTRACT DOCUMENTS. i. SUBMITTAL BY CONTRACTOR REPRESENTS THAT FIELD MEASUREMENTS, FIELD CONSTRUCTION CRITERIA, MATERIALS, CATALOG NUMBERS AND SIMILAR DATA HAVE BEEN DETERMINED AND VERIFIED BY CONTRACTOR. B. SHOP DRAWINGS: SUBMIT ONE REPRODUCIBLE AND TWO PRINTS; PROV IDE FOR CUSTOM PRODUCTS AND PRODUCTS NOT FULLY IDENTIFIED BY PRODUCT DATA. C. PRODUCT DATA: SUBMIT NUMBER REQUIRED BY CONTRACTOR PLUS TWO FOR OWNER'S PROJECT MANAGER; INDICATE ITEM TO BE USED WHERE DATA FOR MORE THAN ONE PRODUCT OR OPTION 15 INCLUDED; PROVIDE FOR EACH STOCK MANUFACTURED ITEM. D. MANUFACTURER'S CERTIFICATES: PROVIDE TWO. E. COORDINATION: COORDINATE USE OF PREMISES AND ACCESS TO SITE UNDER DIRECTION OF OWNER; COORDINATE WORK TO ASSURE EFFICIENT AND ORDERLY SEQUENCE OF INSTALLATION OF CONSTRUCTION ELEMENTS. 1. MAKE PROVISIONS FOR OWNER INSTALLED ITEMS AND FOR SEPARATE CONTRACTS. 2. VERIFY CHARACTERISTICS OF INTERRELATED OPERATING EQUIPMENT ARE COMPATIBLE; COORDINATE WORK HAVING INTERDEPENDENT RESPONSIBILITIES FOR INSTALLING, CONNECTION TO, AND PLACING SUCH EQUIPMENT IN SERVICE. 3. COORDINATE SPACE REQUIREMENTS AND INSTALLATION OF MECHANICAL AND ELECTRICAL WORK; CONCEAL PIPES, DUCTS, AND WIRING IN FINISHED AREAS; COORDINATE LOCATIONS OF FIXTURES AND OUTLETS WITH FINISHES. SECTION 01400 - QUALITY REQUIREMENTS A. GENERAL QUALITY CONTROL: MAINTAIN QUALITY CONTROL OVER SUPPLIERS, MANUFACTURERS, PRODUCTS, SERVICES, SITE CONDITIONS, AND WORKMANSHIP, TO PRODUCE WORK OF SPECIFIED QUAL ITY. B. MANUFACTURER'S FIELD SERVICES: WHEN SPECIFIED IN RESPECTIVE SPECIFICATION SECTIONS, REQUIRE MANUFACTURER OR SUPPLIER TO HAVE QUALIFIED PERSONNEL PROVIDE ON -SITE OBSERVATIONS AND RECOMMENDATIONS. 1. REPRESENTATIVE SHALL: A. OBSERVE FIELD CONDITIONS, INCLUDING CONDITIONS OF SURFACES_ 03SERVE QUALITY OF WORKMANSHIP AND METHODS OF INSTALLATION. B. PROVIDE RECOMMENDATIONS FOR INSTALLATION AND WORKMANSHIP. C. WHERE REQU I RED, START, TEST, AND ADJUST EQUIPMENT AS APPLICABLE D. SUBMIT WRITTEN REPORT TO OWNER'S PROJECT MANAGER OF a85ERVATIONS. C. MOCK -UPS: CONSTRUCT FIELD SAMPLES AND MOCK -UPS ON SITE AS REQUIRED. D. TESTING LABORATORY SERVICES: TESTING SHALL BE BY AN APPROVED TESTING LABORATORY, AS REQUIRED BY SPECIFICATIONS AND BY APPLICABLE CODES. 1. TESTING REQUIRED WILL BE PAID FOR BY OWNER EXCEPT RETESTING WILL BE PAID FOR BY CONTRACTOR WHERE REQUIRED BY FAILURE TO MEET ORIGINAL TESTS. 2. CONTRACTOR SHALL FURNISH MATERIALS AND SAMPLES FOR TESTS AND 514ALL ASSIST TESTING LABORATORY AS REQUESTED. SECTION 01500 - TEMPORARY FACILITIES AND CONTROLS A. GENERAL: PROVIDE TEMPORARY CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS AS REQUIRED TO COMPLETE PROJECT IN ACCORDANCE WiTH CONTRACT DOCUMENTS AND TO CONFORM WITH REQUIREMENTS OF APPLICABLE AUTHORITIES. 1_ CONTRACT GOVERNING AUTHORITIES TO ESTABLISH EXTENT OF TEMPORARY FACILITIES AND TEMPORARY CONTROLS REQUIRED BY AUTHORITIES. B. TEMPORARY PLOWER: PROVIDE POWER SERVICE AND LIGHTING REQUIRED FOR OPERATIONS, WITH BRANCH WIRING AND DISTRIBUTION B0LE5 LOCATED TO ALLOW SERVICE AND LIGHTING BY MEANS OF ION -TYPE POWER CORDS. C. TEMPORARY WATER AND SANITARY SERVICES: PROVIDE AND MAINTAIN REQUIRED DRINKING WATER AND SANITARY FACILITIES WITH D. NOISE, DUST, AND POLLUTION CONTROL: PROVIDE MATERIALS AND EQUIPMENT NECESSARY TO COMPLY WITH LOCAL REQUIREMENTS FOR NOISE, DUST, AND POLLUTION CONTROL. E. BARRIERS: PROVIDE AS REQUIRED TO PROTECT ADJACENT PROPERTIES FROM DAMAGE FROM OPERATIONS; AND AS REQUIRED BY GOVERNING AUTHORITIES. I. BARRICADE AS REQUIRED BY CITY OR LANDLORD, IN ACCORDANCE WITH ALL CODES, CRITERIA, AND DETAILS. 2. SECURITY: MAINTAIN SITE AND MATERIALS SECURE DURING CONSTRUCTION PERIOD. F. CLEANING: CONTROL ACCI.11.ILATION OF WASTE MATERIALS AND RUBBISH; DISPOSE OF OFF -SITE AT INTERVALS APPROVED BY 0#84ER'S PROJECT MANAGER AND ACCEPTABLE TO APPLICABLE AUTHORITIES. G. SIGNS: SUBJECT TO APPROVAL OF GOIER S PROJECT MANAGER_ 44_ STORAGE: LIMIT Or -SITE STORAGE TO AREAS DESIGNATED FOR CONSTRUCTION OPERA TIONS AND APPROVED IN WxIT1NG IN ADVANCE BY C» 4ER; PROVIDE ADDITIONAL WEATHER- TIGI4T, SECURED OFF-SITE STORAGE AS REQUIRED_ I_ REI OVAL AND CLEANING: REMOVE CONSTRuCTION FACILITIES, CLEAN AND REPAIR DAMAGE, IN EXCESS OF CONTRACT REaJIRE'1BNTS, CAUSED BY OPERATiONIS OR USE OF TB PORARY FACILITIES. SECTION 01600 - PRODUCT REQUIREMENTS A- CONT'''RACT Amami: BASE OA MATERIALS AND PRODUCTS IN CONTRACT WHERE LISTED AN CONTRACT DCCIXTENTS, MATERIALS AND PRODUCTS - ANuFACTuRERS NOT LISTED SSNAL.L NOT BE USED WITIGJT NRIT DI APPROVAL B PRODUCTS- COMPONENTS SUPPLIED #4 QUAUTr'Tr SHALL BE RVIRCilApwaz PRO/ DE NON MATERIALS ;./NESS OT1it5E DIRECTED IN CONTRACT DOQN'ENTS C_ MIS�AW./►" ]�I AIS' ALL 'E,'S PLO 'S, LEVEL AND SECURE, AND IN C CT RE-A - 0 AOJACENNT Oltr;OuCr5c 5EC.JRE AS PLACE NrT Inn ANIC.>r1O1'AGE D(VCE5 QED AND S+ZED ♦0 pormiSTAND 5TRe'SSES, V1esATO4, AND RACOUNG_ COr"Pi.• mr'M mAN FACTURIFR RECOMENDATICK5 NC MSTA ..fuA ION INSTRLC''IC1N6 EXCEPT iNSERE MORE STRINGENT REGuIREmmrs AiRE 5P'BGFIED_ D_ TRARSPdRTAra PRODUCTS TO AVOID PROCIUCT DAMAGE, W'.E, tOELJVER IN .14D& CAGED CLADrTIO4 M PAN LINER MED CONTAINERS OR FAiOCAG+AIG_ E- +► I4CLI PROVDE EGUIPmENT AND PERsoNNEL TO N AN L.E PROCLUICTS BY METHODS TO PREVENT SOU. % AND DAMAGE E PRO P TLY IA$'ECT TO AWARE PRODUCTS NRE COMECT, CO 1R„ T , AND GuANTMES CORRECT F. STORAGE STcRE I" aTERIJ. i«N ACCORDANCE INrT1N I"liAN FACt1JRIM •ISTRU TiONS, lotne SEALS AND LABELS SIITACT NC LEGIBLE_ i PROVIDE COVEI1b15`S TO Mp PRODUCTS vWrar& Mr TRAFFIC MC cN7 STIR icTOs OPERATORS, Wen MEN NO LONGER Imo_ U- SPECIFIED PRODUCTS i IR PRIMUCTS SPECIFIED Sr IW ONE OR MOE PIKJOLUCTS OR MANUFACTURERS, , SB$T PRODUCTS OF AMY' NAM MAINUFACTIMEN MEETING SF SECTION 01630 - SUBSTITUTIONS AND PRODUCT OPTION A. SUBSTITUTIONS AND PRODUCT OPTIONS: PROVIDE PRODUCTS INDICATED OR APPROVED; REQUESTS FOR SUBSTITUTIONS OF OTHER PRODUCTS WILL BE CONSIDERED IF SUBMITTED IN WRITING. I. CONTRACTOR OPTIONS: PROVIDE PRODUCTS AND MANUFACTURERS NAMED IN SPECIFICATIONS, SUBMIT REQUEST FOR SUBSTITUTION FOR PRODUCTS AND MANUFACTURERS NOT SPECIFICALLY NAMED WHERE NAMES ARE LISTED. 2. SUBSTITUTIONS: CONTRACTOR SHALL INVESTIGATE PROPOSED SUBSTITUTIONS AND DETERMINE IF EQUIVALENT TO PRODUCTS SPECIFIED. SUBMITTALS SHALL INCLUDE COST OR TIME BENEFITS FOR SUBSTITUTIONS; FAILURE TO INDICATE COST OR TIME BENEFIT 15 JUSTIFICATION FOR REJECTION. 3 . CONTRACTOR'S REPRESENTATION: REQUESTS CONSTITUTE THAT CONTRACTOR HAS INVESTIGATED PROPOSED PRODUCTS AND DETERMINES IT MEETS OR EXCEEDS SPECIFIED PRODUCTS AND WAIVES CLAIMS FOR ADDITIONAL COSTS THAT SUBSEQUENTLY BECOME APPARENT. 4. APPROVALS: OWNER'S PROJECT MANAGER SHALL BE JUDGE OF ACCEPTABILITY AND RESERVES RIGHT TO REJECT PROPOSED SUBSTITUTION BASED ON INSUFFICIENT INFORMATION; USE ONLY SUBSTITUTIONS APPROVED IN WRITING. SECTION 01700 - EXECUTION REQUIREMENTS A. INSTALLER QUALIFICATIONS: INSTALLERS TO HAVE MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE INSTALLING ITEMS SIMILAR TO THOSE REQUIRED FOR PROJECT, EXCEPT FOR INDIVIDUALS IN TRAINING UNDER DIRECT SUPERVISION OF EXPERIENCED INSTALLER. B. EXAMINATION: BEGINNING INSTALLATION OF A PRODUCT SIGNIFIES INSTALLER HAS EXAMINED SUBSTRATES, AREAS, AND CONDITIONS FOR COMPLIANCE WITH MANUFACTURER REQUIREMENTS FOR TOLERANCES AND OTHER CONDITIONS AFFECTING PERFORMANCE. C. MANUFACTURER'S INSTRUCTIONS: WHEN WORK iS SPECIFIED TO COMPLY WITH MANUFACTURERS' RECOMMENDATIONS OR INSTRUCTIONS, DISTRIBUTE COPIES TO OWNER'S PROJECT MANAGER. D. INSTALLATION: COMPLY WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS UNLESS MORE RESTRICTIVE REQUIREMENTS ARE SPECIFIED. E. PROTECTION: COVER PRODUCTS SUBJECT TO DETERIORATION WITH IMPERVIOUS SHEET, PROVIDE VENTILATION TO AVOID CONDENSATION AND TRAPPING WATER. F. CUTTING AND PATCHING: CUT AND FIT COMPONENTS AS REQUIRED; PATCH DISTURBED AREAS TO MATCH ADJACENT MATERIALS AND FINISHES. I. REFINISHING: REFINISH ENTIRE SURFACES AS NECESSARY TO PROVIDE EVEN FINISH TO MATCH ADJACENT FINISHES; FOR CONTINUOUS SURFACES REFINISH TO NEAREST INTERSECTION, FOR AN ASSEMBLY REFINISH ENTIRE UNIT. G. FINAL CLEANING: CLEAN INTERIOR AND EXTERIOR SURFACES EXPOSED TO VIEW, REMOVE TEMPORARY LABELS, STAINS, AND FOREIGN SUBSTANCES; POLISH TRANSPARENT AND GLOSSY SURFACES; VACUUM CARPETED AND SOFT SURFACES; CLEAN DUCTS; CLEAN SITE. H. SUBSTANTIAL COMPLETION: PROV IDE DOCUMENTATION STATING WORK 14A5 BEEN SUBSTANTIALLY COMPLETED. WHERE OWNER REQUIRES USE OF SPACE PRIOR TO FINAL COMPLETION, PROVIDE LIST OF ITEMS TO BE COMPLETED. 1. OWNER'S PROJECT MANAGER WILL REVIEW LIST OF ANY ITEMS TO BE COMPLETED AND SUPPLEMENT LIST WITH ITEMS CONSIDERED TO BE INCOMPLETE OR UNACCEPTABLE. I. FINAL COMPLETION: PROVIDE WRITTEN CERTIFICATION INDICATING WORK 15 IN COMPLIANCE WITH CONTRACT DOCUMENTS, SYSTEMS WAVE BEEN TESTED AND ARE OPERATIONAL, AND WORK IS READY FOR FINAL INSPECTION. J. PROJECT RECORD DOCUMENTS: MAINTAIN COMPLETE AND UP -TO -DATE RECORD DOCUMENTS; KEEP SEPARATE FROM FIELD DOCUMENTS. SUBMIT PROJECT RECORD DOCUMENTS, MATERIAL AND FINISH DATA, OPERATION AND INSTRUCTION MANUALS, WARRANTIES AND BONDS AT COMPLETION. 1. SUBMIT BOUND IN 6 -1/2' X II' THREE RING BINDERS WITH DURABLE PLASTIC COVERS. ARRANGE IN FORMAT SIMILAR TO SPECIFICATIONS. K. WARRANTIES: PROVIDE WARRANTIES AS INDICATED, SIGNED BY CONTRACTOR AND MANUFACTURER; FORM AS APPROVED BY OWNER PRIOR TO EXECUTION. 1. WARRANTIES SHALL BE IN ADDITION TO AND NOT A LIMITATION OF OTHER RIGHTS OWNER MAY HAVE AGAINST CONTRACTOR UNDER CONTRACT DOCUMENTS AND AS PRESCRIBED BY LAW, REGARDLESS OF WORDING OF WARRANTY. 2. PROVIDE A LIST OF SUBCONTRACTORS CONTACTS AND PHONE NUMBERS IN A FRAME MOUNTED ON OFFICE DOOR. SECTION 01735 - SELECTIVE DEMOLITION A. SELECTIVE DEMOLITION: REMOVE FROM SITE • EXISTING MATERIALS, CONSTRUCTION AND UTILITIES AS NEEDED TO COMPLETE PROJECT. REMOVE EXISTING ELEMENTS INDICATED AND DURING CONSTRUCTION, AS NEEDED TO COMPLETE WORK. 1. REMOVE ONLY THOSE ELEMENTS NECESSARY FOR COMPLETION OF PROJECT, REPLACE OR REPAIR ELEMENTS UNMNECESSARiLY REMOVED OR DAMAGED DURING CONSTRUCTION. 2. CAREFULLY REMOVE AND STORE ITEMS INDICATED FOR REUSE IN PROJECT AND COORDINATE WITH OTHER TRADES FOR MODIFICATIONS AND REINSTALLATION. 3. PROTECTION: PREVENT MOVEMENT AND SETTLEMENT OF ADJACENT STRUCTURE; PROVIDE BRACING, SHORING, AND UNDERPINNING AS NEEDED AND BE RESPONSIBLE FOR SAFETY AND SUPPORT OF STRUCTURES. ASSUME LIABILITY FOR SUCH MOVEMENT AND SETTLEMENT. 4. UTILITIES: CONTACT APPLICABLE UTILITY COMPANIES PRIOR TO DISCONNECTING UTILITIES; DISCONTINUE WORK IF UNEXPECTED UTILITY LINES ARE ENCOUNTERED. DETERMINE LINE SOURCE AND USE PRIOR TO REMOVAL CAP AND IDENTIFY EXISTING UTILITY LINES REMOVED. 'SECTION 01800 - SYSTEMS DEMONSTRATIONS A. SUMARY: PROJECT INCLUDES SPECIAL FACILITY START -UP PROCESS TO BRING FACILITY TO FULLY OPERATIONAL STATE, FREE OF DEFICIENCIES, IN MOST EFFICIENT AND TIMELY MANNER ACHIEVABLE. DIVISION THREE: CONCRETE SECTION 0'640 - CEr NT'1TCU5 Uh1DERLAYMENT A. GENERAL: PROVIDE POURED CEMENTMOUS UNDERLAYMENT SYSTEM, NOT INTENDED AS FINISHED TRAFFIC SURFACE, NCLUDING AICGESS RTES AS REQUIRED FOR COMPLETE INSTALLATION_ B. SLEIMITTALS: FURNISH MANUFACTURER'S LITERATURE_ C. INSTALLEW FIRM WiTH KAMUM 5 YEARS SUCCESSFUL EXPERIENICE, REGULARLY ENGAGED IN INSTALLATION OF SPECIFIED MATERIALS, PROPERLY EQUIPPED AND ACCEPTABLE TO MAN uFACTURER O. MAiAJFACTURER: ARM, INC/K-15 IN .REONSAL COJSELF- LEVELING NEAR TOPPING. E. SYSTEM: POURABLE CEMENTmOUS, NIGH- STRENGTH, FAST - SETTING, NON- SIRMC, SELF- LEVELING UN DER AYMB T mammal 417100 PSI COMPRESSIVE STRENGTh AT 26 DAYS, ASTM 0349_ TOLERANCE IS TO BE 1/6' OVER TEN FEET F_ INISTALLATIQ* arils riTI4 MANUFACTURER RECCPMADATIONS AND INSTALLATION INSTRUCTIONS G. FURNISH AND 'INSTALL fir BASED, OR APPROVED EQUAL., MANUFACTURER RECOMENDED LEVELN6 CG POLaC AT SENSORMAT PANEL UNITS. (SEE DETAIL IN ELECTRICAL DRAMMGiS ) C- DIVISION FOUR: MASONRY SECTION 04850 - STONE ASSEMBLIES A. GENERAL: PROVIDE STONE FABRICATIONS FOR CLADDING AS INDICATED ON DRAWINGS, INCLUDING ANCHORS, MORTAR, GROUT, AND ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. 8. QUALITY CONTROL: OBSERVE STONE DURING FABRICATION AND ENSURE CONSISTENCY OF APPEARANCE. 1. DEFECTS AND BLEMISHES: CONTRASTING SPOTS, FOREIGN ELEMENTS, IRREGULAR COLOR VARIATIONS, AND IRREGULARITIES IN TYPICAL CHARACTER SHALL BE CONSIDERED DEFECTS AND BLEMISHES. C. COMPOSITE STONE: AS INDICATED ON DRAWINGS; EACH TYPE OF STONE SHALL COME FROM A SINGLE MANUFACTURER TO INSURE CONSISTENT COLOR. D. MORTAR AND GROUT MATERIALS: ASTM C150, TYPE 1 PORTLAND CEMENT, ASTM C207, TYPE S HYDRATED LIME, AND ASTM C144 SAND, CLEAN, FREE OF HARMFUL SUBSTANCES; USE WHITE CEMENT AT COLORED MORTAR AND GROUT, COLOR TO MATCH STONE UNLESS OTHERWISE INDICATED. E. ACCESSORIES: PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE SYSTEM. F. FABRICATION: PROVIDE STONE WITH EXPOSED SURFACES SMOOTH, TRUE AND FLAT. G. FABRICATION: FABRICATE AS SHOWN AND AS DETAILED ON FINAL SHOP DRAWINGS WITH EXPOSED SURFACES SMOOTH, TRUE, AND FLAT. 1. CUT ACCURATELY TO SHAPE AND DIMENSIONS SHOWN ON FINAL SHOP DRAWINGS; COMPLY WITH FABRICATION TOLERANCES OF THE STONE ASSOCIATION (ICE GRANITE INSTITUTE) FOR SPECIFIED FINISHES. ZERO TOLERANCE WHERE HAIRLINE JOINTS ARE REQUIRED. A. INSTALLATION: DO NOT USE MATERIAL WITH CHIPS, CRACKS, VOI DS, DISCOLORATION OR OTHER DEFECTS THAT MIGHT BE VISIBLE OR CAUSE STAINING iN FINISHED WORK. I. STONE APPLICATION: INSTALL CURBS WITH SOFT STAINLESS STEEL WIRE ANCHORS, MINIMUM 1/8' DIAMETER SET WITH PORTLAND CEMENT WITH SHRINKAGE REDUCER (EXTERIOR); GROUT JOINTS. 2. EXECUTE WORK WITH SKILLED MECHANICS AND EMPLOY SKILLED FITTERS AT SITE TO DO NECESSARY FIELD CUTTING AS STONE IS SET. 3. TOOL JOINTS SLIGHTLY CONCAVE. DIVISION FIVE - METALS SECTION 05500 - METAL FABRICATIONS A. GENERAL: PROVIDE MISCELLANEOUS METAL SHAPES AND FABRICATIONS AS REQUIRED AND NOT INCLUDED AS PART OF OTHER SECTIONS, WITH ANCHORS AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. 8. SUBMITTALS: FURNISH SHOP DRAWINGS FOR CUSTOM FABRICATIONS, PRODUCT DATA FOR MANUFACTURED ITEMS; PROVIDE TEMPLATES FOR ANCHOR INSTALLATION BY OTHERS. C. STEEL SHAPES: ASTM A36 STEEL. D. GROUT: PROVIDE NON - SHRINK, NONMETALLIC, PREMIXED, FACTORY PACKAGED, NON- STAINING, NON- CORROSIVE, NON - GASEOUS GROUT; TYPE SPECIFICALLY RECOMMENDED BY MANUFACTURER FOR APPLICATIONS INDICATED. E. FASTENERS AND ROUGH HARDWARE: TYPE REQUIRED FOR SPECIFIC USAGE; PROVIDE ZINC- COATED FASTENERS FOR EXTERIOR USE OR WHERE BUILT I NTO EXTERIOR WALLS. F. WELDING MATERIALS: AW5 D1.1, TYPE REQUIRED FOR MATERIALS BEING WELDED. G. PAINT: PROVIDE PRIMERS AS RECOMMENDED BY PAINT MANUFACTURERS FOR SUBSTRATES AND PAINTS SPECIFIED IN SECTION 09900 - PAINTING. 1. GALVANIZING REPAIR PAINT: HIGH ZINC -DUST CONTENT PAINT FOR REGALVANIZING WELDS IN GALVANIZED STEEL. H. FABRICATION: FABRICATE ITEMS WITH JOINTS NEATLY FITTED AND PROPERLY SECURED; GRIND EXPOSED WELDS CONTINUOUS, SMOOTH AND FLUSH WITH ADJACENT FINISHED SURFACES, AND EASE EXPOSED EDGES TO APPROXIMATE 1/32' UNIFORM RADIUS_ 1. MAKE EXPOSED JOINTS FLUSH BUTT TYPE, HAIRLINE JOINTS WHERE MECHANICALLY FASTENED. 2. FIT AND 5HOP ASSEMBLE IN LARGEST PRACTICAL SECTIONS FOR DELIVERY. I. FINISHES: GALVANIZE AND PRIME PAINT EXTERIOR MISCELLANEOUS METAL, PRIME PAINT INTERIOR MISCELLANEOUS METAL; GALVANIZE COATING MINIMUM G90 COATING, GALVANIZED AFTER FABRICATION. I. CLEAN SURFACES OF RUST, SCALE, GREASE AND FOREIGN MATTER PRIOR TO APPLYING GALVANIZED OR PAINTED FINISH. J. INSTALLATION: INSTALL ITEMS SQUARE AND LEVEL, ACCURATELY FITTED AND FREE FROM DISTORTION OR DEFECTS DETRIMENTAL TO APPEARANCE OR PERFORMANCE; ENSURE ALIGNMENT WITH ADJACENT CONSTRUCTION; COORDINATE WITH RELATED WORK TO ENSURE NO INTERRUPTION IN INSTALLATION_ 1. SUPPLY ITEMS REQUIRING TO BE CAST INTO OR EMBEDDED IN OTHER MATERIALS TO APPROPRIATE TRADES. 2. AFTER INSTALLATION, TOUCHUP FIELD WELDS AND SCRATCHED AND DAMAGED SURFACES; USE PRIMER CONSISTENT WiTH SHOP COAT OR RECOMMENDED FOR GALVANIZED SURFACES, AS APPLICABLE. K. METAL FRAMING: CONFORM TO ASTM 0754; COMPLETE 16 GAGE AND LIGHTER STEEL STUDS AND SUSPENSION SYSTEMS FOR GYPSUM BOARD SYSTEMS (SEE DIVISION 9 SECTION MAO). PROVIDE ACCESSORIES REQUIRED FOR COMPLETE INSTALLATION SECTION 05700 - ORNAMENTAL METALS A. GENERAL: PROVIDE CUSTOM ORNAMENTAL METAL ITEMS AS INDICATED WITH ACCESSORIES AND ATTACHMENT DEVICES AS REQUIRED FOR COMPLETE, FINISHED INSTALLATION. I. ORNAMENTAL METAL ITEMS: INSTALL STAINLESS STEEL AND BREAK METAL SHAPES AS INDICATED ON DRAWINGS. B. FABRICATOR: FIRM WITH MINIMUM FiVE YEARS SUCCESSFUL EXPERIENCE FABRICATING ORNAMENTAL METAL ITEMS SIMILAR TO THOSE REQUIRED FOR PROJECT. STAINLESS STEEL: ASTM ALA, TYPE 302/304 CORROSION RESISTANT STAINLESS STEEL WITH NO. 4 SATiN DIRECTIONAL FINISH. D. BRACKETS MD ANCHORS: UNEXPOSED PLATES, ANGLES AND SUPPORTS MAY BE STEEL; EXPOSED ITEMS TO MATCH ORNAMENTAL METAL TYPE AND FINISH. E. FASTENERS: TYPE REQUIRED FOR SPECIFIC USAGE; PROVIDE CONCEALED FASTENERS EXCEPT WHERE SPECIFICALLY APPROVED; WHERE EXPOSED MATCH TYPE AND FINISH OF METAL BEING FASTENED. 1- CONCEALED STEEL FASTENER HOT - DIPPED GALVANIZED MINIMUM G90 /*ERE BUILT INTO EXTERIOR WALLS CR SUBJECT TO HIGH NUM F. FABRICATION: FABRICATE COMPONENT CONNECTIONS TO SUPPORT SPECIFIED DESIGN LOADS. 1. SEj. EcT MATERIALS FOR , FREE OF DEFECTS AND IRREGULARITIES 2. EXPOSED-TO-VIEW SURFACES EXHIBITING PiTTNG, SEAM MARKS, RONL.LER MARKS 'OIL CANNING, STAINS, DISCOLORATION, AND IMPERFECTIONS ON FINISHED UNITS ARE NOT ACCEPTABLE 3. MAKE EXPOSED JOINTS FLUSH BUTT TYPE, HAIRLINE JOINTS /44ERE MECHANICALLY FASTENED; PROVIDE CONCEALED CONNECTION DEVICES WiTH HIDDEN FASTENERS OR AS DETAILED. 4. SEPARATE DIS5t 11LAR MATERIALS WITH SITLJMINAJS PANT WHERE CONCEALED, WTZN PERFORMED SEPARATORS, OR SIMILAR METHOD TO PREVENT CORROSION_ G. INSTALLATION: INSTALL ORNAMENTAL. METAL iTE1'!S IN ACCORDANCE WirTH MANuFACTUREWS T1OlS, INSTALLATION INSTRUCTIONS, AND APPROVED SNOOP DRAM NGS. I. INSTALL PLUMB, TRUE AND iN CORRECT RELATION TO ADJACENT NORK, FREE FROM DISTORTOI OR DEFECTS DETRITIENTAL TO APPEARANCE AND PERFORMANCE 2 PRIOR TO SECURING CCP4TINUOUS iTEMS, ADJUST TO ENSURE PROPER MATO NG AT BUTT JOINTS AM CORRECT ALIGNMENT NT ''i /GI~TC,>t,3T nEiR Legarw. 3. REPAIR OR REPLACE MEWS DAMAGED OR MARRED DURING PO43 DIVISION SIX - WOOD AND PLASTICS SECTION 06105 - MISCELLANEOUS ROUGH CARPENTRY A. GENERAL: PROVIDE MISCELLANEOUS ROUGH CARPENTRY. B. STANDARDS: COMPLY WITH REQUIREMENTS OF AMERICAN PLYWOOD ASSOCIATION (APA), AND APPLICABLE CODE REQUIREMENTS. PLYWOOD: PROVIDE MINIMUM APA C -D EXTERIOR (COX) PLYWOOD; STRESS RATED WHERE SPANNING SUPPORTING MEMBERS; FIRE RETARDANT TREATED; MINIMUM 3/4' THICK UNLESS OTHERWISE INDICATED. PLYWOOD STANDARD: COMPLY WITH PSI (ANSI A199.I) PLYWOOD PANEL BOARDS: PROVIDE PANEL BOARDS FOR ELECTRICAL AND COMMUNICATION PANEL BOARDS; APA C -D PLUGGED, INTERIOR TYPE PLYWOOD WITH EXTERIOR GLUE, FIRE RETARDANT TREATED; MINIMUM 1/2" THICK. D. FASTENERS: PROVIDE FASTENERS AS REQUIRED FOR COMPLETE, SECURE INSTALLATION OF MISCELLANEOUS ROUGH CARPENTRY; GALVANIZED AT EXTERIOR LOCATIONS AND PRESSURE TREATED WOOD; SIZE AND TYPE TO SUIT APPLICATION; PROVIDE WASHERS FOR NUTS AND BOLTS. E. INSTALLATION: COMPLY WITH REFERENCED STANDARDS AND APPLICABLE CODE REQUIREMENTS. 1. PLYWOOD: COMPLY WITH RECOMMENDATIONS OF AMERICAN PLYWOOD ASSOCIATION (APA) FOR FABRICATION AND INSTALLATION OF PLYWOOD WORK. 2. PLACE MISCELLANEOUS ROUGH CARPENTRY TRUE TO LiNES AND LEVELS. 3. CORRELATE LOCATION SO ATTACHED WORK WILL COMPLY WITH DESIGN REQUIREMENTS AND BE PROPERLY LOCATED. 4. CONSTRUCT MEMBERS OF CONTINUOUS PIECES OF LONGEST POSSIBLE LENGTHS. 5. FIT CARPENTRY WORK TO OTHER WORK; SCRIBE AND COPE AS REQUIRED FOR ACCURATE FIT. 6. SECURELY ATTACH CARPENTRY WORK TO SUBSTRATES BY ANCHORING AND FASTENING AS REQUIRED BY RECOGNIZED STANDARDS. 7. PROVIDE WASHERS UNDER BOLT HEADS AND NUTS IN CONTACT WITH WOOD. C. SECTION 06200 - FINISH CARPENTRY A. STANDARDS: CONFORM TO ARCHITECTURAL WOODWORK INSTITUTE (MO/QUALITY STANDARDS OR WOODWORK INSTITUTE OF CALIFORNIA (WIC) "MANUAL OF MILLWORK' STANDARDS; MINIMUM WIC/CUSTOM GRADE. 8. SUBMITTALS: FURNISH PRODUCT DATA FOR MANUFACTURED ITEMS, SHOP DRAWINGS FOR CUSTOM ITEMS, SAMPLES OF EACH EXPOSED FINISH. C. CERTIFICATION: CERTIFICATION WILL NOT BE REQUIRED. D. DELIVERY, STORAGE AND HANDLING: COMPLY WITH AWI OR WIC STANDARDS AND MANUFACTURE RECOMMENDATIONS. E. NON -SALES WOOD SHELVING: MI OR VI IC/CUSTOM GRADE HARDWOOD -EDGED PLYWOOD. I. ADJUSTABLE SHELVING BRACKETS: INSTALL HEAVY DUTY STANDARDS AND BRACKETS WITH SLOTS 2' ON CENTER, SUPPORTS MAXIMUM 24' APART, AND MINIMUM 12" SHELF BRACKETS UNLESS OTHERWISE INDICATED. F. RECEIVE 4 INSTALL OWNER PROVIDED, PRIMED WOOD WALL BASE 1. COPE ALL IN- CORNERS, MITER ALL OUTSIDE CORNERS. 2. BACK OUT AS REQUIRED TO PREVENT WRAPPING. DRILL WHERE NECESSARY TO PREVENT SPLITTING. 3. COUNTER SINK 4 PUTTY ALL NAIL HOLES, SAND SMOOTH G. ANCHORS, NAILS AND SCREWS: SELECT THE MATERIAL, TYPE, SIZE AND FINISH REQUIRED BY EACH SUBSTRATE FOR SECURE ANCHORAGE; PROVIDE TOOTHED STEEL OR LEAD EXPANSION BOLT SCREWS FOR DRILLED -IN -PLACE ANCHORS. H. WORD FILLER: COLOR TO MATCH WOOD BEING FILLED. I . FABRICATION: FABRICATE FINISH CARPENTRY ITEMS IN ACCORDANCE WiTH SPECIFIED QUALITY STANDARD. J. INSTALLATION: INSTALL WORK CONSISTENT WITH SPECIFIED QUALITY GRADE, PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS; SHIM AS REQUIRED, USING CONCEALED SHIMS_ K. PREPARATION FOR FIELD FINISHING: SAND WORK SMOOTH AND SET EXPOSED NAILS AND SCREWS; APPLY WOOD FILLER IN EXPOSED NAIL AND SCREW INDENTATIONS AND LEAVE READY TO RECEIVE SITE- APPLIED FINISHES. 1. SEAL CONCEALED AND SEMI - CONCEALED SURFACES; BRUSH APPLY ONLY, USING PRIMER CONSISTENT WITH FINISH COATS SPECIFIED UNDER SECTION 09900 - PAINTS AND COATINGS. SECTION 06400 - ARCHITECTURAL WOODWORK A. GENERAL: INSTALL OWNER FURNISHED CASEWORK AND COUNTERTOPS; PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B. STANDARDS: CONFORM TO ARCHITECTURAL WOODIe URK INSTITUTE (A141)/QUALITY STANDARDS OR WOODWORK INSTITUTE OF CALIFORNIA (WIC) 'MANUAL OF MILLWORK' STANDARDS; MINIMUM PREMIUM GRADE. C. SUBMITTALS: FURNISH PRODUCT DATA FOR CONTRACTOR FURNISHED ACCESSORIES INCLUDING SAMPLES OF EXPOSED MATERIALS. D. STORAGE AND HANDLING: COMPLY WITH MANUFACTURER RECOMMENDATIONS. E. ACCESSORIES: PROVIDE AS INDICATED AND AS REQUIRED TO INSTALL ARCHITECTURAL WOODWORK AS INDICATED; COORDINATE ACCESSORIES REQUIRED FOR INSTALLATION OF OWNER FURNISHED ARCHITECTURAL WOODWORK NOT FURNISHED WITH ARCHITECTURAL WOODWORK. F. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND REFERENCED STANDARDS. TAKE SPECIAL CARE COORDINATING INSTALLATION OF OWNER FURNISHED ARCHITECTURAL WOODWORK WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS. I. INSTALL WORK CONSISTENT WITH SPECIFIED QUALITY GRADE, PLUMB, LEVEL, TRUE AND STRAIGHT WiTH NO DISTORTIONS. 2. SCRIBE MD CUT FOR ACCURATE FiT TO OTHER FINISHED H. 3. ENSURE MECHANICAL AND ELECTRICAL ITEMS AFFECTING ARCHITECTURAL WOODWORK ARE PROPERLY PLACED, COMPLETE, AND HAVE BEEN INSPECTED BY OWNER'S PROJECT MANAGER PRIOR TO COMMENCEMENT OF INSTALLATION. 4. SECURE WORK TO GROUNDS, STRIP'P'ING AND BLOCKING WITH CONCEALED FASTENERS AND BLIND NAILING AS REQUIRED FOR A COMPLETE INSTALLATION. S. SCRIBE AND CUT FOR ACCURATE FiT TO OTTER FINISHED WOR.lC. 6. INSTALL ARCHITECTURAL WOODWORK UNDER SUPERVISION OF FACTORY- TRAINED MECHANICS_ 7. ATTACH ARCHITECTURAL NQODWORK SECURELY IN PLACE WITH UNIFORM JOINTS PROVIDING FOR THERMAL AND BUILDING MOVEMENTS. 6 - ACCEPTABLE TOLERANCES: A. VARIATION FROM TRUE POSITION MAXIMUM 1/16' AT ANY POSITION AND MAXImUM 1/6' N ANY 10 -0' LHNGTH. G. ADJOINING Af..ES OF SAME MATERIAL: NO VARIATION PERMITTED_ o r, sk Wit - � 4 l c - C SHREIUSHOCK ARCHITECTS, INC. 6130 S. S ISURY ROAD SUITE 100 COLUMBIA, OM 43081 614 - 545 -4550 - www.shr•mshock.com co co 0 0 O 6923 _CD !!!'n o ( J 0 iOW4=a o'1 '1 W W U 2 W 2 N Z a _O00 t az :; 111.1'24 o i rN OE iI2W ° a La '1 MI E a Z,n�, d y;W W W aiii0 ft- rani t = J its.. riUm '� - a ; ,� a3° u rca- y ~ M Z Q Z C.0 I ins a 0U x 00► --- ° 4 z,,,,--z... ,. z #rte, o 4!!ii = _uoan =,... rm3o4010 W .� c c W ,o W � Z' za LU Ida I- Ui3 J o Pr) limn --ww co 2 _• saCrls r! Mme s !mmr DATE ISSUElk DESIGNED IT: GRAM Mt D It GISTERED 7 CT D S SMRELASHOCK STA' OF WASHINGTQM 4,1 1i - w ie ^a 2 y N C i.=Z„ 0 r 4 3 m i r= 0 , U 2 = j 0 rw...a0 a ,0 U J iZU� ''!" O 4 Z O Q " � V <WN UZ 0 02O a m W,�..=0 ZOYaO 2� Oi2 i2 P <�� '' rW ° m~a ► 3:� V ° aF-� d aiW �.= v,UaW 3°.- d� mi°0 W WWV 1 UOC WOJ D J FZZ tU d „ U j a: , N oFQ `� ° TO C7 Sp� yz oa°[ Z' � ° OeVe WC'.W3° �zaci is <Y� � a 7�OW V i i i�OW ~ m o �' „ t V U r Z r- 0. J GGd ]- Z NOZ26► 21''12!09 iO �0<rr iiZX J° i� ^°►-WW �"ZZ V 0'1 _ ::! :.;:517:2 Z =a , u ar W ar ar- 1Li V W } 7•lOn 012 S10 aUC V r Z ..0i Gtr PA =.6 t; REVISIONS: 0 ri MUM A15.1 rQ • 0 3 i W Z 0 0, X C W N J a 0 U 0 0 U 0 U .. 0 -2 4 1( cc ]C W V Z a. 0i W p O N z N. p z: ' 0 Q G 4J o iY IF' V a. O et r - CIL W Z V U W N N o J 111F3JwE: G• OBI '3/T6/C3 SF NOP ass SPECIFICATIONS 41 or L. 0 I' oir SECTION 09770 - PREFINISHED FIBERGLASS WALL PANELS (F.R.P.) A. GENERAL: PROVIDE PREFINISHED GLASS FIBER REINFORCED POLYESTER RESIN FABRICATED WALL PANELS, WITH TRIM PIECES AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. 8. MANUFACTURERS: KEMLITE COMPANY/KEMLITE FIRE -X GLA58ORD PLUS, SEQUENTIA, SET. INC. /STRUCTOGLAS PYRO PANL SYSTEM, OR NUDO PRODUCTS, INC. /FIBER -LITE PANELS, CLASS C. PANELS: FIBERGLASS REINFORCED PLASTIC (FRP) PANEL SYSTEM; NOMINAL 0.090' THICKNESS; WHITE. I. FIRE - RATING: CLASS I (UL CLASS A), MAXIMUM 25 FLAME SPREAD, 25 SMOKE GENERATION BASED ON ASTM E64. INSTALLATION. D. TRIM PIECES: MANUFACTURER'S STANDARD MATCHING MOLDINGS AND TRIM PIECES AS REQUIRED FOR COMPLETE, FINISHED INSTALLATION, AND AS REQUIRED FOR JOINTS, CORNERS AND PANEL EDGES. E. ADHESIVE; MANUFACTURER'S RECOMMENDED NONTOXIC, WATERPROOF ADHESIVE SUITABLE FOR SUBSTRATES INDICATED. F. PRIMER: PROVIDE NON - STAINING RELEASE COAT PRIMER AS RECOMMENDED BY WALL PANEL MANUFACTURER WHERE PANELS ARE APPLIED TO GYPSUM BOARD. G. MECHANICAL FASTENERS: CONCEALED TYPE ONLY; TYPES AS RECOMMENDED BY SYSTEM MANUFACTURER. H. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE REQUIREMENTS FOR FIRE RATINGS. COPE AND MITER TRIM PIECES. INSTALL PANELS IN MAXIMUM SIZE INCREMENTS AVAILABLE. I. INSTALL WALL PANELING BEFORE INSTALLATION OF PLUMBING, BASES, HARDWARE, AND SIMILAR ACCESSORIES. 2 . SECURELY ADHERE PANELS TO WALL SURFACES; USE BLIND NAILING METHODS AS REQUIRED TO SUPPORT PANELS UNTIL ADHESIVE DRIES; EXPOSED MECHANICAL FASTENERS SHALL NOT BE ACCEPTABLE. REMOVE EXCESS ADHESIVE FROM EDGES; WIPE SEAM CLEAN WITH DRY CLOTH TOWEL. SECTION 09900 - PAINTS AND COATINGS A. GENERAL: PROVIDE PAINTING OF EXPOSED ITEMS AND SURFACES NOT PREFINISHED, AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B. SURFACES NOT TO BE PAINTED: PREFINISHED ITEMS; CONCEALED AND INACCESSIBLE AREAS, CODE- REQUIRED LABELS. C. STANDARDS: PROVIDE MATERIALS APPROVED FOR USE BY APPLICABLE AIR QUALITY MANAGEMENT DISTRICT FOR LIMITATIONS OF VOLATILE ORGANIC COMPOUNDS FOR ARCHITECTURAL COATINGS. D- SUES" IITTAJS: FURNISH PRODUCT DATA AND SAMPLES. 1 . DUPLICATE PAINTED FINISHES OF APPROVED SAMPLES ON ACTUAL WALL SURFACES AND CAIPONDITS FOR APPROVAL PRIOR TO COMMENCING WORK. E- DELIVERY: DELIVER MATERIALS TO JOB SITE IN ORIGINAL, NBAI AND UNOPENED PACKAGES AND CONTAINERS BEARING MANUFACTURER'S NAME AND LABEL. F. MANUFACTURER: BENJAMIN MOORE G MATERIAL QUALITY: PROVIDE TOP UNE QUALITY COMMERCIAL GRADE (PROFESSIONAL PAINTER) PAINTS; MATERIALS NOT BEARING MANUFACTURER'S IDENTIFICATION AS A BEST -GRADE PRODUCT SHILL NOT BE ACCEPTABLE. 1 - PRIMERS: PROVIDE PREMIUM GRADE PRIMERS RECOMMENDED BY PAINT MANUFACTURER FOR SUBSTRATES INDICATED AND FOR FINISH SYSTEMS SPECIFIED. 2 . UNDERLOATS AND BARRIER COATS: PROVIDE UNDERCOAT PAINTS PRODUCED BY SAME MANUFACTURER AS FINISH COATS; USE ONLY THINNERS APPROVED BY PAINT MANUFACTURER, AND USE ONLY WITHIN RECOMMENDED UNITS. 3- FINISH COATS: PROVIDE FINISH COATS CAPABLE OF BEING WASHED WITH MILD DETERGENT WITHOUT LOSS OF COLOR, SHEEN, OR PIGMENTS. 4_ FINISH COAT COORDINATION: PROVIDE FINISH COATS WHICH ARE COMPATIBLE WITH PRIME PAINTS, UNDERCOATS, AND BARRIER COATS USED. VOLATILE ORGANIC COMPOUNDS: PRCA/IDE MATERIALS WITH MINIMAL VOLATILE ORGANIC COMPOUNDS (VOC); COMPLY WITH APPLICABLE REGULATIONS. H. COLORS AND KNISHES: PURE, NON - FADING, APPLICABLE TYPES TO SUIT SERVICE INDICATED; NO LEAD CONTENT PERMITTED. I. PREPARATION: PERFORM PREPARATION AND CLEANING PROCEDURES IN ACCORDANCE WITH PANT MANUFACTURER'S INSTRUCTIONS AND AS SPECIFIED FOR SUBSTRATE CONDITION. I. EXAMINE AREAS AND CONDITIONS UNDER WHICH PAINTING WORK IS TO BE APPLIED. START OF PAINTING WORK INDICATES ACCEPTANCE OF SURFACES AND CGP ITK*IS OF SURFACES AND CONDITIONED WITHIN ANY PARTICULAR AREA. 2 . REMOVE HARDWARE, ACCESSORIES, AND ITE395 IN PLACE AND NOT TO BE PAINTED, OR PROVIDE PROTECTION PRIOR TO SURFACE PREPARAT AND PAINTING; AFTER PAINTING REINSTALL REMOVED ME M& -I APPLICATION: APPLY PAINT IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS; USE APPLICATORS AND TEGMIQJES BEST SUITED FOR SUBSTRATE AND TYPE OF MATERIAL.. BEING APPLIED. 1 - APPLY ADDTTKONAL COATS WHEN STAINS OR BLEMISHES 51.04 THROUGH FINAL COAT, UNTIL PAINT IS A LMIFORM1 FINISH, COLOR AND APPEARANCE. 2 . FINISH DOU7R5 ON TOPS, BOTTOMS AND SIDE EDGES SAME AS FACES. PROVIDE EXTRA ATTENTION TO ASSURE DRY FILM THIOQNESS AT CORNERS MID CREVICES IS EQUIVALENT TO THAT OF FLAT SURFACES. 3 - PAINT SURFACES BB4IND MD/ABLE EQJIPMBNT AM FURNITURE SAME AS SIMILAR EXPOSED SURFACES; PAINT SURFACES BEHIND PERMANENTLY-FIXED EQUIPP 4T AND FURNITURE WITH PRII~E COAT ONLY. 4 - PAINT BACK SIDES OF AC,CE55 PANELS AND REITNAHLE OR HINGED COVERS TO MATCH EXPOSED SURFACES. 5. SAW LJGUTLY BETWEEN EA -1 SUCCEEDING ENNIEL. NV EACH VARNISH COAT. K- SCHEDULING PAINTING- APPLY FIRST COAT TO SURFACES TWAT NAVE SEEN CLEANED, PRE TREATED OR PREPARED FOR PANTING AS 5024 AS PRACTICABLE AFTER PREPARATIQI. - ALLOW TIME BETWEEN SUCCESSIVE COATINGS TO PERMIT PROPENt DRYING _ DO NOT RECOIAT LJINTIL PAINT FEELS FIRM AND DOE'S NOT DEFORM OR FEEL STICKY UNDER MODERATE TI• Ire PRESSURE_ L mow COATING: TACENESS APPLY MATERIALS AT PCT LESS T14/W MANUFACTURER'S RECOMINDED SPREADING RATE, TO ESTABLISH A TOTAL DRY F LP1 THICXNE 5 AS RECOM ENVED BY COATING MANUFACTURER_ URER_ N . PR/ ME COATS: APPLY TO ITE IS NOT PREY OU L'r PRIMED; RECOAT PRIMED NC SEALED SURFACES W/NERE T LS EVIDENCE OF SLCTIO 4 SPOTS OR LOISEALED AREAS i4 FIRST COAT it Row COATS PROODE EVE% 'Dr:JRE: LEAVE NO LAPS, IRREGIA.ARTTY !i! TErroti., slap *1ALIi KS, OR OTTER SURFACE ravENFEcroe 00 PANT SYSTEMS PRO/DE J1' TWO COAT 'ER SYSTEM_ I. ay. PANTED '"E'rAL._ 5eF - G..QSS rig ACR'r'i.IC_ 2 - GYPSUM BOA. iI."^ hM1r,...5r- EGGS►giL (Skink) .J►'TX EMIAS 4 3- GYPSUM"' BO C Et4.AM'.& ..A J►' EX EMULSION 1 TOILET' "?' wA,_,_S AND CEt.NGFs SE3" -4055 ACRY':.c EIIMr'EL S. «''r Pa4irED "'E & set -4a.056 W I ACR'".C. 6- CCMOREIT. r. GEAR FIENF 'NtAT SEAL.. Gt c oa SYS B' AG er AeL,E- 7- FLOOR 5' p'ES TRAFFIC maw !COI -SLAo' Sire PAW_ C_ Cd►T S'VB- ACCEPTApJLE b- gL CO IP " •rrli• AST" REF6.ECTANICE OF PANT IP GLEN: -UP= CURING FINMPEX5 OF PCIRX., REmVI FJeCAi W PAi 1r riATER Ak.5,. FLeers4, CAME: MD was Mgr SITE AT END OF EAKOI+ Day'`_ t- CLEAN GLASS AND PAINT --SPA TT rrpRDIATLIT OT PICvBt INIETNI DS OF NA A% MID SCRAPING, i,BING CARE TO 5OU'ATO1 OR DAMAGE FINSIED SrUJrISF�Iaras. E rillgrE r rgra t OF OrI "MIE S,,, INrE'T TO !E PANTED OR ger, anistr c r'MGE ST CL,EILI % IEINMINIII G OR RIEI'LACI ,, AMC I N1EP II'1Ii AS lTE TO ONIllerS FOOJECT t. 1E r "Aar sae Tai Pioricr RIEI1Y- 1 N8'R7rE nErvawrr r"UIOTECnvE Ur ERAS ri7t r1UpIrELros aF 7 CF OW R HAIR A l arlitETIOS OF NEM OF O!I "NUM MUM. NW 111E3TOE OM'Mi i /11111111FalaS Olt teraCip PAWED SECTION 10680 - COMPACT MOBILE STORAGE UNITS A. GENERAL: INSTALL OWNER FURNISHED MOVABLE COMPACT STORAGE SYSTEM; PROVIDE ACCESSORI AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B. EXAMINATION: EXAMINE SUBSTRATES AND CONDITIONS UNDER WHICH COMPACTED STORAGE SYSTEM IS TO BE INSTALLED. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. C. INSTALLATION: COMPLY WITN MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS. 1. INSTALL UNITS AND ACCESSORIES AT LOCATIONS SHOWN IN ACCORDANCE WITN MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS, LEVEL, PLUMB, SECURE AND AT PROPER HEIGHT. 2. INSTALLATION TO BE SUPERVISED BY FACTORY TRAINED PERSONNEL; MANUFACTURER REPRESENTATIVE TO MAKE PERIODIC SITE INSPECTIONS OF INSTALLATION WHILE IN PROGRESS. D. CLEANING: CLEAN UNITS AND REPAIR OR REPLACE DAMAGED UNITS AS DIRECTED BY OWNER'S PROJECT MANAGER. TOUCHUP MARRED FINISHES OR REPLACE COMPONENT PARTS AS NECESSARY TO ELIMINATE EVIDENCE OF DAMAGE OR DETERIORATION. E. PROTECTION: PROVIDE PROTECTION FOR INSTALLED SYSTEM TO ENSURE PERFECT OPERATING CONDITION WITHOUT DAMAGE AT COMPLETION OF PROJECT. SECTION 10610 - TOILET ACCESSORIES A. GENERAL= PROVIDE TOILET ACCESSORIES AS REWIRED FOR COMPLETE FINISHED INSTALLATION. B. CODES AND REGULATIONS COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS WITH DISABILITIES. C. MANUFACTURERS: E1[,HRICK, BRADLEY, OR AMERICAN SPECIALTIES. D. TYPES: STAINLESS STEEL ACCESSORIES AS INDICATED ON DRAWINGS; PROVIDE GRAB BARS WITH CONCEALED MOJNTING, SIZES AND SHAPES AS INDICATED AND AS REQUIRED BY APPLICABLE CODES AND REGULATIONS. E. MATERIALS: STAINLESS STEEL, ASTM MK, COMMERCIAL GRADE, TYPE 302/304, NUMBER 4 SATIN FINISH, SATIN COME ACCEPTABLE WHERE STAINLESS STEEL IS NOT AVAILABLE FOR ACCESSORY ITEM SO4EDUL.ED; GAGES AS STANDARD WITH MANUFACTURER OF SPECIFIED I. FASTENERS, SCRB45, AND BOLTS: HOT DIP GALVANIZED; AS REC TIENDED BY ACCESSORY MANUFACTURER FOR COMPONENT AND SUBSTRATE. 2. CONCEALED SURFASC PRETREAT AND CLEAN, SPRAY APPLY OM COAT PRIMER AND BAILED B4AMEL. FINISH. F. FABRICATION: WELD AND GRID SMOOTH JOINTS OF FABRICATED , FORM EXPOSED SURFACES FROM ONE SHEET OF STOCK, FREE OF JOINTS. I. FABRICATE UNITS WITH TIGHT SEAMS NV JOINTS, EXPOSED EDGES ROLLED; I.IANG DOORS AND ACCESS PANELS WITN CONTINLICUS PIANO IINGE'5; PROVIDE CONCEALED ANCRORAGE MERE P1 SSeLE 2. PROVIDE STEEL. ANWOR PLATES AND MOOR arromeas FOR INSTALLATION. 3. FORM SURFACES FLAT •ITHOUJT DISTORTION; MAINTAIN FLAT SURFACES WI'T3NOUT SCRATCHES AND WTTHOUT DENTS, FINISH EXPOSED EDGES EASED, FREE OF SHARP EDGES 644ERE POTENTIAL EXISTS FOR PHYSICAL CONTACT. NOT DIP GALVANIZE FERROUS METAL ANK4OR5 AND FASTENING DEVICES. 5. SOP AS5E"LE COMPONENTS; PACK. GE COMPLETE WITH ANC340115 AND FITTINGS_ G_ NSTALLATIAI= CO"PL.Y WITH MANUFACTURER H AC'TURER TONS AND APPLICAB CODES AND REGULATIONS. r1703.42.4 G 1 T` i r e ;_4t5 -•.r� r u- Ir '4L SECTION 09720 - VINYL WALL COVERING GENERAL: INSTALL VINYL WALL COVERING AND PROVIDE ACCESSORIES AS - " IRED PLETE FINISHED INSTALLATION. ENANCE INSTRUCTIONS: FURNISH MANUFACTURER'S RECOMMENDED IALS AND APPLICATION METHODS, INCLUDING PRECAUTIONS IN MATERIALS WHICH MAY BE DETRIMENTAL TO SURFACES : MAHARAM - COBBLE COVERING CONFORMING TO FS DD - 408, E I NG, MINIMUM 24 TO 26 OZ.; WITN MAXI (UL CLASS A, UBC C.LASS I ). E RECOMMENDED BY WALL , NON -TOXIC B. C. D. E. F. G. H. MA CLEAN! MANUF TYPE: VINYL WITH CLOTH DEVELOPED, ASTTI ADHESIVE: NONTOXIC APPLICATION. PRIMER: PROVIDE NON -STAI WALL COVERING MANUF 1 PROVIDE PRIMER hlHICH WITHOUT DAMAGING PAPER F OF WALL COVERING EXAMINATION: ENSURE SURFACES T OF IRREGULARITIES, DO • COMM 1 - ENSURE WALL 5U . F 10' -0 NOR PREPARATION: OTHER MI W ITH SURF • APPLICAT RECOMM It\ a r a i. • a A WALL COVERING E SPREAD AND SMOKE UFACTURER TO SUIT T PRIMER AS RECOMMENDED BY WALL COVERING FROM GYPSUM BOARD AND WITHOUT PREMATURE SEPARATION WALL COVERING ARE CLEAN, TRUE AND FREE UNTIL SURFACES ARE SATISFACTORY. DOES NOT VARY MORE THAN IN IN /16' PER RUNNING FOOT. ATIONS; FILL NICKS, GOUGES AND ILLER; SAND 51100TH, FLUSH ACTURER'S RECOMMENDATIONS WITH MANUFACTURER'S ADHESIVE IN IN NO CLOSER E . • • _ • WITH ESS T RATE GREATER UFACTURER'S RECOMM OF SUBSTRATES WITH LA IME COAT IN ACCORDANCE WITH AND APPLY WALL COVERING IN AND INSTALLATION INSTRUCTIONS; MIX AND ITN ADHESIVE MANUFACTURER'S RECOMMENDATIONS. FABRIC PANELS IN EXACT ORDER AS CUT FROM ROLLS; USE IVE ORDER AS NUMBERED BY MANUFACTURER. HOR IZONTAL SEAMS AND CUTTING AT CORNERS ARE NOT ACCEPTABLE; THAN 2' OF AN INSIDE CORNER, AND NOT CLOSER THAN 4' OF AN OUTSIDE 3. FILL SPACES ABOVE AND BELOW WINDOWS, DOORS, AND SIMILAR AREAS IN 5 FROM ROLL. a n.2 SECTION A. GENERAL: G.C. TO COORDINATE MANAGER. TALLATION WITH OWNER'S PROJECT DETAILS. TO PROVIDE BLOCKING AS co co SHREMSHOCK ARCHITECTS, INC. 6130 S. SUNBURY ROAD SUITE 100 COLUMB(*, ON 43081 614 -545 -4550 www.shrsmshock.com O 6923 EGISTERED HITECT CD n� *ability; !r DATE apt DESIGNED Vf: DRAIRII SY: BALD S S . �' STATE OF WASHINGTON r z z a. OE C I14 fl w H .,W.n hiii! Nq mz V 7 N O d I, NO O 3 N W •EaL„i°.70 OW ~ 0 u1�1uR (jW W Z x Nr pNW4! �. Nr00p t- � ?N � M0 r zN , . ._ o C. s ~ n ~ i 4 ti o ° °C ar° '"`. W �WrN d a a raci n ci p cr Wr' =W - x0xcn0 30r, - w0 W7 w i. 3 W t V J 40m3"-= 0 z,, 0d\ ZnO 0-.-3t... m 0 = z al O p m ` z= p 1 1. ta M z _ 2 N 0 0 w Z . - z ..,le 3 d i u� �" odzc� °� I,, 3 W 01.; a 7:::4[:: J W J J - � Woo _ I W Z Z a �i w�Q X r- o� W ca bt ar- - tr. 1~ - • •ocsts s s• +s r. w- z REVISIONS: z A15.3 ti z 0 - z o W,u :::::: V 3 - � ,. , px'.O o z "+ 7 0. z Wn.N0 MZZO. W 07W V [3 0 d O t.��pO WN •p * _ l < UrZ_ J '. z 0 ooY:,,0, - 0 � = :: rt =Z V W W rQ � p nn , )-) - = 0 S,T Uo " r V .. i t r VU•�=07t ur O O N c!I O 2 v QO O 0 O O W 0 0 Lai IF- U a o '- a. Z W v U o V o I fH O J •z '0/76/C3 SF NOP IISS SPECIFICATIONS DIVISION TEN - SPECIALTIES SECTION 10160 - METAL TOILET COMPARTMENTS A. GENERAL: PROVIDE FLOOR MOUNTED METAL TOILET COMPARTMENTS AND WALL MOUNTED URINAL SCREENS WITH ACCESSORIES AS REQUIRED FOR COMPUTE FINISHED INSTALLATION; COORDINATE WITH TOILET ACCESSORIES. I. COORDINATE WITH TOILET ACCESSORIES. B. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS WITH DISABILITIES. C. SUBMITTALS: SUBMIT PRODUCT DATA, SHOP DRAWINGS, AND SAMPLES. D. MANUFACTURERS: SANYMETAL, GLOBAL, OR FLUSH METAL. E. TYPE: FLOOR MOUNTED TOILET PARTITIONS AND WALL MOUNTED URINAL SCREENS. I. FINISH: STANDARD BAKED ENAMEL FINISH COLOR AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL LINE OF COLORS. F. PILASTER SHOES: 3' HIGH; ASTM AMA, TYPE 302/304, NO. 4 POLISHED FINISH; STAINLESS STEEL. G. ATTACHMENTS, SCREWS AND BOLTS: 51 AINLESS STEEL; TAMPER PROOF TYPE; HEAVY DUTY EXTRUDED ALUMINUM BRACKETS. H . HARDWARE: MANUFACTURER'S STANDARD CHROME PLATED OR SIMILAR FINISH. 1. HINGES: NONFERROUS CAST PIVOT HINGES, GRAVITY TYPE, ADJUSTABLE FOR DOOR CLOSE POSITIONING. 2. LATCH: SLIDE LATCH; DOOR STRIKE AND KEEPER WITH RUBBER BUMPER. 3. COAT HOOK/BUMPER: CAST ALLOY CHROME PLATED COMBINATION UNIT. 4. WALL BUMPER: CAST ALLOY WALL MOUNTED RUBBER BUMPER FOR OUT SWINGING 6. MM. COMPLY WITH REQUIREMENTS FOR PROVIDING ACCESS FOR PERSONS WITH DISABILITIES. I. INTERNAL REINFORCEMENT: PROVIDE INTERNAL REINFORCEMENT IN AREAS OF ATTACHED HARDWARE AND FITTINGS; MARK LOCATIONS OF REINFORCEMENT FOR PARTIT MOUNTED WASHROOM ACCESSORIES. J. PREPARATION: EXAMINE SITE CONDITIONS TO WHICH WORK IS TO BE APPLIED; TAKE SITE DIMENSIONS AFFECTING THIS WORK. A. ENSURE CORRECT SPACING AND SIZE OF PLUMBING FIXTURES; TAKE SPECIAL NOTE OF FIXTURES IN COMPARTMENTS INDICATED TO BE DESIGNED FOR PERSONS WITH DISABILITIES TO ASSURE CLEARANCES COMPLYING WITH ACCESS REGULATIONS. K. INSTALLATION: INSTALL UNITS IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS, SECURE, PLUMB, LEVEL, AND SQUARE; LEAVE I/2' SPACE BETWEEN WALL, PANELS AND END PILASTERS. 1. ADJUST HINGES TO LOCATE DOORS IN PARTIAL OPEN POSITION WHEN UNLATCHED, EXCEPT ADJUST HINGES TO RETURN DOORS TO CLOSED POSITION AT STALLS DESIGNED FOR USE BY PERSONS WITH DISABILITIES. 2. ANCHOR URINAL SCREEN PANELS TO WALLS WITH TWO PANEL BRACKETS. L. CLEANING: FIELD TOUCHUP OF SCRATCHES AND DEFACED FINISHES WILL NOT BE PERMITTED; REPLACE DAMAGED, SCRATCHED AND MARRED DEFECTIVE MATERIALS WIN NEW, UNDAMAGED MATERIALS; REMOVE PROTECTIVE MASKING; CLEAN SURFACES FREE OF OIL AND IMPERFECTIONS. SECTION 10265 - CORNER GUARDS A. GENERAL: INSTALL STAINLESS STEEL CORNER GUARDS WITH ATTACHMENT DEVICES AND ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B. MANUFACTURERS: AMERICAN DISPENSER/59q, BOBRICK/B633, BRADLEY/991 OR PARKER/NO. 7. C. TYPE: STAINLESS STEEL UNITS WITH SATIN FINISH, 3 -1/2" X 3.1/2' X 40 HIGH CORNER GUARDS; MINIMUM 18 GAGE. PAINT GRIP FINISH AT SALES FLOOR. D. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS. SECTION 10500 - LOCKERS A. GENERAL: INSTALL OWNER FURNISHED METAL LOCKERS; PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B. INSTALLATION: INSTALL LOCKERS IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS, SECURE, PLUMB, LEVEL, SQUARE, AND IN LINE. i_ BOLT ADJOINING LOCKER UNITS TOGETHER TO PROVIDE RIGID INSTALLATION. 2. INSTALL METAL BASES, END PANELS, AND FILLER PANELS TO CLOSE OFF OPENINGS AND AS REQUIRED FOR COMPLETE INSTALLATION. sal • • • • 4. le • GENERAL NOTES ALL NOTES INCLUDED HEREIN ARE MADE PART OF EACH AND AU. MECHANICAL. ELECTRICAL AND PLUMBING SECTIONS OF WORK. 1. REFER TO LANDLORD'S SPECIFICATIONS AND TENANT DESIGN CRITERIA FOR NECESSARY INFORMATION AND COORDINATION WITH OTHER TRADES. 2. SHEET 14101.1 COVERS DIVISION 15 DESCRIBING IN DETAIL 15000 BASIC MECHANICAL REQUIREMENTS AND 15500 HEATING VENTILATING AND AIR CONDITIONING. SHEET P01.1 COVERS DIVISION 15 DESCRIBING IN DETAIL 15000 BASIC MECHANICAL REQUIREMENTS. 1 5200 PLUMBING; 1 5300 FIRE PROTECTION. SHEET E01.1 COVERS DIVISION 16 DESCRIBING IN DETAIL 16000 BASIC ELECTRICAL REQUIREMENTS: AND 16050 BASIC ELECTRICAL MATERIALS AND METHODS 3. THE ABBREVIATION LSD&C WHEREVER IT APPEARS IN THE DRAWINGS. SHALL REFER TO "UNITED STORE DESIGN AND CONSTRUCTION ". ANY REFERENCE TO TENANT, BRAND SPECIFIC (UMITED, ETC.) OR FURNISHED BY ANY OF THE ABOVE REFERS TO LSD&C 4. ANY DISCREPANCY BETWEEN LSD&C DRAWINGS AND TENANT CRITERIA, LSD&C DRAWINGS SHALL TAKE PRECEDENCE. 5. THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC TO THE EXTENT THAT ALL INSTALLED ITEMS AND LOCATIONS ARE NOT EXACTLY PLACED AND ARE NOT TO BE SCALED. 6. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR HIS PERMITS AND INSPECTION FEES. 7. BEFORE COMMENCING ANY WORK, CONTRACTORS SHALL REVIEW THE LATEST NATIONAL. STATE AND LOCAL CODE REQUIREMENTS INCLUDING LANDLORD CRITERIA AND PERFORM THE WORK IN STRICT ACCORDANCE WITH THESE. IN CASE OF CONFLICT THE STRICTER REQUIREMENTS WILL PREVAIL 8. 0. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF AU. EXISTING CONDITIONS PRIOR TO SUBMITTING HIS BID. ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE GENERAL CONTRACTOR, LSD&C OR THE LANDLORD'S FIELD REPRESENTATIVE FOR CLARIFICATION. b. AFTER BID. ANY QUESTIONS RELATING TO SPECIFIC M, E. OR P ISSUES ARE TO BE DIRECTED AS RFI'S THROUGH THE LSD&C PROJECT MANAGER. C. SHOULD THE SPACE HAVE BEEN INACCESSIBLE FOR INSPECTION CONTRACTOR MUST INDICATE SO ON HIS BID. EACH CONTRACTOR IS RESPONSIBLE FOR VISITING THE JOB SITE PRIOR TO SUBMITTING HIS BID FOR THE PURPOSE OF SURVEYING EXISTING CONDITIONS, WHICH MAY AFFECT THE WORK TO BE DONE UNDER THIS SECTION. NO ADDITIONAL COMPENSATION SHALL BE MADE FOR ANY CHANGE ORDERS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOBSITE AND /OR PRE - DETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS BID. 9. THE GENERAL CONTRACTOR'S FIRE SPRINKLER SUB - CONTRACTOR SHALL DESIGN AND INSTALL FIRE SPRINKLER SYSTEM CONFORMING TO LANDLORD'S CRITERIA, TENANT'S REQUIREMENTS AND PER LOCAL CODES AND NFPA STANDARDS. 10. THE CONTRACTOR, WITHIN FIFTEEN (1 5) DAYS OF THE AWARD OF THE CONTRACT, SUBMIT TO THE OWNER. SIX (6) COPIES OF A COMPLETE UST OF MATERIALS AND EQUIPMENT PROPOSED FOR THE JOB INCLUDING ALL DATA, PART NUMBER. RATING CAPACITY, SIZE, DIMENSIONS, ELECTRICAL DATA, GRADE, MANUFACTURER, AND ANY OTHER DESCRIPTIVE DATA FOR ALL EQUIPMENT OR SYSTEMS THAT DEVIATE FROM SPECIFIED ITEMS. ANY DELAYS OR COSTS DUE TO THESE DEVIATIONS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 11. CONTRACTOR SHALL. BE RESPONSIBLE FOR THE DISPOSAL OF ALL UNUSED OR ABANDONED MATERIALS AND EQUIPMENT, AND ITS REMOVAL OFF THE LANDLORD'S PREMISES. 12. OWNER RESERVES THE RIGHT TO HAVE CONSTRUCTION REVIEWED BY AN OUTSIDE CONSULTANT PRIOR TO ACCEPTANCE OF THE PROJECT 13. 0. EACH CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND woRKIAANSHIP RELATED TO HIS WORK FOR A MINIMUM PERIOD OF ONE YEAR FROM THE DATE WHICH THE OWNER ACCEPT THE PROJECT. THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER OR TENANT SHALL CORRECT ANY DEFECTS IN MATERIALS OR WORKMANSHIP DURING THIS GUARANTEE PERIOD. b. EACH CONTRACTOR SHALL BE RESPONSIBLE AND ENSURE A CLEAN INSTALLATION ESPECIALLY IN EXPOSED CEILNNG AREAS. THE FINAL APPROVAL OF THIS WORK WILL BE ISSUED BY LSD&C PROJECT MANAGER. 14. PROVIDE THREE SETS OF "AS- BUILT' DRAWINGS AND TWO BOUND SETS OF ALL OPERATIONS MANUALS, DIAGRAMS, SERVICE CONTRACTS AND GUARANTEES TO LSD&C PRECEDENT TO FINAL PAYMENT. INDEPENDENT AIR BALANCE CONTRACTOR HIRED BY G.C. MUST INCLUDE CLOSE -OUT PACKAGE. HVAC GENERAL NOTES 1. THESE PLANS MAY BE USED FOR CONSTRUCTION ONLY AFTER APPROVAL IS OBTAINED FROM THE BUILDING DEPARTMENT MECHANICAL PLAN CHECK DIVISION AND THAT DIVISION'S STAMP APPROVAL AND AUTHORIZED SIGNATURE APPEAR ON THE PLANS. COORDINATE ALL WORK MATH ARCHITECTURAL, ELECTRICAL, PLUMPING, FIRE SPRINKLER AND STRUCTURAL CONTRACTORS. INSTALL ALL WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL AMD STRUCTURAL MIE'MBERS. NO ITEM SUCH AS PIPE, DUCT, ETC. IS TO BE IN CONTACT WITH ANY EQUIPMNENT. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOLITION wORIL 4. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE LOCATION. S. REFER TO SHEETS E00.0. TC0.1 AND "M" SERIES SHEETS FOR MECHANICAL DETAILS. SCHEDULES AND SPECIFICATIONS. 6. CONTRACTOR SHALL PROVIDE CUT SHEETS TO LSD&C FOR ALL EQUIPMENT ANND DEVICES FURNISHED UY THE CONTRACTOR THAT DEVIATE FROM SPECIFIED ITEM FOR REVIEW AND APPROVAL PRIOR TO THE PURCHASE OF ANT SUCH EQUIPMENT OR DEVICES. 7. HVAC CONTRACTOR IS RESPONSIVE TO INQUIRE NTTH THE LM OLORD% REPRESENTATra ON ANY SMOKE EVACUATION SYSTEM IN USE AT TIC MALL AT THE THE OF THE BD. IF THE SOLD SYSTEM IS NOT ADEQUATELY DOOMED ON THE ORAIINGS. THE ME04A NICAL CONTRACTOR IS RESPONSia IX TO WORN THE GENERAL CONTRACTOR /MID INCLUDE THE COST AS A SEPARATE LIE ITEM M THE WO. ND ADDITIDISM. NOS SHALL BE AWARDED FOR TIE-M REQUIREMENTS TO A LANDLOADI SNOICE EVACUATION SYSTEM THAT IS M EXISTENCE AT THE TM1E OF THE MD, WITHOUT A SEPARATE UNE ITN/ FOR TIC SMIOME EYACLAT1 N SYSTEM AT THE TIME OF THE SID.. a. ACCESS TO ALL COMPONENTS AND EQUIPMENT MNUST K PR0vIDED TO MEET COPE AND EASE. IL PRIOR TO STARTUP OF HAIAC EOUJ!'MEMT. NECHANICAL CONTRACTOR iglu COMM' W11TN MAC YMRIFAICTU R DMT CONNECT POUR E PROVIDED TO LSOMlC PROIAED HL/AC UNITS MD HMS KEN T1IRarE I ON A t RAR1 OF 24 NOUNS. LSo,c DES THE RIIC ET TO CHECK c GTRM1GT ON COMMFUANC:E WI/TN PLANS AID SPECI"KAI INS. WOAD TIME mom Fme COIIKCTTNE NOM TO K 1ECI SSAAItr. NE WILL N WY cominuao, OF 911011 WNW SN Masa MIND EMT COMPLIANCE PERFORM MN OK OIEr I' AiEf COIrIECIIME NOW IS BEAM To K NECI3SARY. 11E COST OF IMENSPECTIONS WILL K LODE UT 1ME CONHTMCTMD. IE E mac IS K Of LAIC N OMR 10 Mmr"OOIIE, MANGE OR CORRECT ,AMR COMITIONI G O ERMATIONBML CONONIONS MME Trk PART NINJWMECT10N1. BRAY aR AIER INIIURY to PML'iME W E CONFER, COMMONS N S NOD M NE S'AUL CD11RrIC'TOR 9MRLL N ERECIED M MSC 10 ARDESS 1149 WM II • Wray immat i R RCO N S EVIL ON TIM MME COMINCIOR C;LTIIMM * ACCONRON 1Mit TN!LIM1,, TB>EIM WW2 72 NNW as MITIE M NONCE TIME OWNER NAT. AT IME WOCTIETION TAME We OCR NaMI AMN NNE GONNA RI IORt FOR -V LAME INA - INS K OPKO ME 10 MIT OF FIEFIDONsICIL 4150,11. IONOIDICE TWO FU.IIP I 1. MNI COMPLEUEN M 1111E NOEL CND ORAL ILJ RE wE PROM NCR WINER OF THE S MO NI LENNOX QINERAL NOTES LENNOX EQUIPMENT NOTED HAS BEEN PRE - PURCHASED BY UNITED STORE DESIGN & CONSTRUCTION. WITHIN THE FIRST WEEK OF CONSTRUCTION, THE GENERAL CONTRACTOR OR THEIR MECHANICAL SUB - CONTRACTOR SHALL FAX TO: LENNOX NATIONAL ACCOUNTS ATTN: RAZI DOLE PHONE NO. 614.817.2952 EXT. 224 EMAIL RAZI.DOLE•LENNOXIND.COM THE FAX SHALL STATE THE PHONE NUMBER AND THE FAX NUMBER OF THE CONTACT PERSON RESPONSIBLE FOR SCHEDUUNG AND RECEIVING THE HVAC EQUIPMENT AND ACCESSORIES, DEUVERY ADDRESS EQUIPMENT AND ACCESSORIES ARE TO BE SHIPPED TO AND ANY SPECIAL SHIPPING INSTRUCTIONS REQUIRED. ALLOW A MINIMUM OF TWO WEEKS AFTER CONSTRUCTION STARTS FOR DEUVERY UNLESS SPECIAL ARRANGEMENTS ARE MADE PRIOR TO THE START OF CONSTRUCTION. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY IT • .:, _ IPPIN + TIN RR • IF 11.4 RY • • • . PRIOR TO THE STANDARD TWO WEEKS SCHEDULED. IF THIS INFORMATION IS NOT SENT TO LENNOX NATIONAL ACCOUNTS, THEN THE EQUIPMENT AND ACCESSORIES WILL. SHIP IN ACCORDANCE WITH THE PURCHASE ORDER DATE AND INSTRUCTIONS ISSUED BY LSD & C AND THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR UNLOADING AND STORAGE OF EQUIPMENT UNTIL SUCH TIME AS REQUIRED FOR INSTALLATION ON PROJECT. IF MANUFACTURER'S REP. IS PERFORMING START UP, THEN G.C. AND /OR MECHANICAL CONTRACTOR MUST COORDINATE WITH MANUFACTURER REP. 2 WEEKS PRIOR TO CONSTRUCTION END DATE. ELECTRICAL GENERAL NOTES 1. THESE PLANS MAY BE USED FOR CONSTRUCTION ONLY AFTER APPROVAL IS OBTAINED FROM THE BUILDING DEPARTMENT ELECTRICAL PLAN CHECK DIVISION AND THAT DIVISION'S STAMP APPROVAL AND AUTHORIZED SIGNATURE APPEAR ON THE PLANS. 2. COORDINATE ALL WORK WITH ARCHITECTURAL, MECHANICAL, PLUMBING, FIRE SPRINKLER AND STRUCTURAL CONTRACTORS. INSTALL AU. WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL AND STRUCTURAL MEMBERS. NO ITEM SUCH AS PIPE. DUCT, ETC. IS TO BE IN CONTACT WITH ANY EQUIPMENT. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOLITION WORK. 4. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE LOCATION. 5. REFER TO SHEETS E00.0, TC0.1, AND "E" SERIES SHEETS FOR ELECTRICAL DETAILS, SCHEDULES AND SPECIFICATIONS. 6. CONTRACTOR SHALL PROVIDE CUT SHEETS TO LSD&C FOR AU. EQUIPMENT AND DEVICES FURNISHED BY THE CONTRACTOR THAT DEVIATE FROM SPECIFIED ITEM FOR REVIEW AND APPROVAL PRIOR TO THE PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES. 7. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE LANDLORD'S REPRESENTATIVE ON ANY FIRE ALARM SYSTEM IN THE MALL AT THE TIME OF THE BID. ELECTRICAL CONTRACTOR SHALL ALSO ENSURE FULL COMPUANCE WITH LANDLORD REQUIREMENTS AND LATEST APPLICABLE CODES WHICHEVER IS MORE STRINGENT. IF THE FIRE ALARM SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS, THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR AND INCLUDE THE COST AS A SEPARATE UK ITEM IN THE BID. NO ADDITIONAL MONIES SHALL BE AWARDED FOR TIE -IN REQUIREMENTS TO A LANDLORD'S FIRE ALARM SYSTEM THAT IS IN EXISTENCE AT THE TIME OF THE BID, WITHOUT A SEPARATE LINE ITEM FOR THE FIRE ALARM SYSTEM AT THE TIME OF THE BID 8. ACCESS TO ALL COMPONENTS AND EQUIPMENT MUST BE PROVIDED TO MEET CODE AND SERVICE /MAINTENANCE EASE. 9. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF AU. HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT 10. DESIGN AND CIRCUITRY MAY BE BASED ON AS BUILT DRAWINGS. G.C. AND ELECTRICAL CONTRACTOR SHALL VERIFY ACCURACY OF AS BUILT DRAWINGS. IN CASE OF DISCREPANCY, ELEC. CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONDUITS, CONDUCTORS, BOXES, MISCELLANEOUS FITTINGS. ETC. FOR A COMPLETE OPERABLE SYSTEM FOR HOME RUNS SHOWN. BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATIONS AND LATEST N.E.C. 11. WHERE PRACTICAL AND WHERE CONDUIT CONDITION WARRANTS, CONTRACTOR MAY REUSE APPROPRIATE DOMING CONDUIT SYSTEM. HOWEVER, IT SHALL BE RESPONSIBILITY OF CONTRACTOR TO CORRECT ANY AND ALL EXISTING CODE "VIOLATIONS IN CONDUIT SYSTEMS TO BE REUSED. CONTRACTOR MUST OBTAIN TIC LSD&C PROJECT MANAGER'S PENSION NI WRITING. 12. CONTRACTOR SHALL REMOVE ALL ABANDONED WIRING NOT TO BE REUSED. WIRING SHALL BE DISCONNECTED AND REMOVED FROM CONDUIT OR RACEWAY, TO PANEL BOARD AS IS PRACTICAL CONDUIT TO REMAIN WITH PULL STRING AND CAPPED. 13. IF APPLICABLE, RECONNECT, COMPLETE AND MAKE OPERABLE ALL EXISTING UGHTING, RECEPTACLES AND CIRCUITRY:. 14. PRIOR TO INSTALLING ANY UNDERGROUND CONDUIT, VERIFY CORM SIZES AND POINTS OF SERVICE WITH THE SERVING UTILITIES. 15. IT IS THE RESPONSIBEITY OF THE ELECTRICAL CONTRACTOR TO SCHEDULE ALL ELECTRICAL INSPECTIONS REQUIRED BY TIE (BUILDING DEPARTMENT AND SERVING UTILITIES. 16. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR AND ARCHITECT FOR LOCATION, RESTRICTION AND REQUIREMENTS OF ALL CONCRETE SAWCUTS. S WCUTS SHALL BE PATCHED RI LIKE AND KIND TO MATCH EXISTING CONCRETE. 17. ALL CONDUCTORS ARE TO BE STANDARD ANNEALED COPPER CONDUCTORS WITH TYPE THIN INSULATION, (PRESS NOTED AND SHALL RUN FROM POINT TO POINT IN APPROVED CONDUIT. ALL COMMITS WHEN EXIPOSED IN AREA WITH NO CEILING (EOICEPT STOCKROOM AREAS) SHALL K INSTALLED N RACKED Mt, W/ FITTED COIIOUT AND PARALLEL TO STRUCTURAL iEMERS. 18. AU. CONDUCTORS SHALL K PHYSICALLY DENTI'ED AT EACH END FOR CIICIAT USAGE AND CONTINUITY (VT OTHERS). 19. ALL CONDUITS SHALL K RUN TO SUIT CONDITIONS IN TIE FMB. CONDUIT Ruin ARE SHOWN DIAGRAMMATICALLY ON THESE PLAINS AND 00 NOT NECESSARY REFLECT TIE EXACT UMW LOCATIONS. ALL COMM SMALL K R M RO E SNELL OF WADING AND weER INSULATED COMO TO Avg HIGH ANOIDIT TOPE/MILK CONDOM M. 20. GENERALLY. ALL CONDUIT SMALL BE CONCEALED E]MCEPT FOR UIIINRSNED AREAS. SUCH AS EOUIP EEIR 110016. E>IPOSE0 COMM SMMLL K MANED ONLY AS VOTED ON IRAN MO AS A1PPRO11ED N MOWS PROJECT MIA AUX PA/AMG OF OOKI IT'S. VOTED ON DI M1I1IS OR SPECEKAIDNS NAL NE Ur iR1EwAL, COMIIMCTOR. 21. THE ELECTRICA . AMID IELEP ONE SEITNCES SINS.L K INSTALLED TO TIE KONFINDETS OF THE SEWING UTILITIES. 111E MEA/M E;Rr11E SoLL K AWE 10 11RTNSTAMD THE *IMAM WOW MDUAT CMIRRMMT IELIICATED (ARC) ON 149E LINE IMUDENL. n. Moat 11LL AMINES IN KU MC IRE MERE 23. REAM. PAM EDAM N• TEST AIL OEM FIIrNK& D/. MM f70MOLELMN OF TIE NOW CONTICIOR WELL EMBALM TIE PROM 110111M6 MIER OF 11E s1c51pN (s) ARID NNE MI' ieuusupos m IIIIESBATED F air, win 4111111101IL MIS WS INCLOIONE ANNIoNER R Mae Ar• INMAILIM RECIMIDIL CONE CTVE IS NIIMS 8161 PEE N' man SIM KIM CONIIIINCINONL A. MR111r IL M • 1JSb OD wE Mme? 1111 1_ E '.CUM III wIE a IL1•I .BELL, �E FOR w OF EQUIPMENT, INSPECTION OF EQUIPMENT FOR DAMAGES. VERIFICATION OF EQUIPMENT RECEIVED, INSURING THAT THE EQUIPMENT RECEIVED IS COMPLETE AND MEETS THE SCHEDULED PANELS FOR THE PROJECT. MOVING AND MOUNTING OF SECTIONS AS WELL AS REASSEMBLING OF SAME INTO ONE COMPLETE UNIT PER MANUFACTURER'S REQUIREMENTS. B. ELECTRICAL CONTRACTOR IS TO CONNECT ALL PROVIDED INTERCONNECTING CABLES BETWEEN SECTIONS AND TORQUE CONNECTIONS PER MANUFACTURER'S REQUIREMENTS. C. ELECTRICAL CONTRACTOR IS TO CONNECT UGHTING BRANCH CIRCUITS TO APPROPRIATE LOAD TERMINALS PROVIDED WITHIN IFS ENCLOSURE PER LIGHTING ZONES INDICATED IN THE PANEL SCHEDULE (I.E: ZONE A, B OR C). UNE SIDE WIRING AND UGHTING CONTROL WIRING WILL BE PREWIRED BY MANUFACTURER AT FACTORY. COORDINATE EXACT TERMINAL NUMBER FOR EACH CIRCUIT CONNECTION WITH MANUFACTURER'S DRAWINGS. D. ALL UGHTING, RECEPTACLE AND MISCELLANEOUS BRANCH CIRCUITS NOT SPECIFIED AS BEING CONTROLLED. ARE TO BE WIRED DIRECTLY TO THE CORRESPONDING BRANCH BREAKER IN THE DESIGNATED PANEL E. ALL CONNECTIONS WITHIN THE TELEPHONE /DATA SECTION AND HVAC CONTROL SECTION OF THE IFS ENCLOSURE ARE TO BE PERFORMED BY OTHERS. F. ELECTRICAL CONTRACTOR WILL ONLY BE RESPONSIBLE FOR INSTALLATION OF THE CONDUIT SYSTEM INTO THE LOW VOLTAGE SECTION OF THE IFS PANEL. NMI OS Inc COMIROILS 1. THESE PLANS MAY BE USED FOR CONSTRUCTION ONLY AFTER APPROVAL IS OBTAINED FROM THE BUILDING DEPARTMENT PLUMBING PLAN CHECK DIVISION AND THAT DIVISION'S STAMP APPROVAL AND AUTHORIZED SIGNATURE APPEAR ON THE PLANS. 2. COORDINATE ALL WORK WITH ARCHITECTURAL ELECTRICAL MECHANICAL, FIRE SPRINKLER AND STRUCTURAL CONTRACTOR. INSTALL ALL WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL. AND STRUCTURAL MEMBERS. NO ITEM SUCH AS PIPE, ETC. TO BE IN CONTACT WITH ANY EQUIPMENT. 3. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOUTION WORK. 4. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE LOCATION. 5. REFER TO SHEET E00.0. AND "P" SERIES SHEETS FOR PLUMBING DETAILS, SCHEDULES AND SPECIFICATIONS. 6. CONTRACTOR SHALL PROVIDE CUT SHEETS TO LSD&C FOR ALL EQUIPMENT AND DEVICES FURNISHED BY THE CONTRACTOR THAT DEVIATE FROM SPECIFIED ITEM FOR REVIEW AND APPROVAL PRIOR TO THE PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES. 7. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY THE EXACT LOCATION. SIZES, INVERTS AND CONDITION OF EXISTING SANITARY WASTE PIPING BELOW SLAB, VENT PIPING ABOVE CEILING AND UP THROUGH ROOF AND DOMESTIC COLD WATER SUPPLY PIPING TO TENANT'S DEMISED PREMISES PRIOR TO SUBMITTING BID. NO ADDITIONAL COMPENSATION WILL BE MADE FOR ANY EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOB SITE AND /OR FAILURE TO PREDETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING BID. B. ACCESS TO AU. COMPONENT AND EQUIPMENT MUST BE PROVIDED TO MEET CODE AND SERVICE/MAINTENANCE EASE. 9. THE CONTRACTOR SHALL VERIFY WITH LOCAL CODES AS TO THE REQUIREMENT /INSTALLATION OF ANY "WATER SAVING" DEVICES TO THE PLUMBING FIXTURES. (EXAMPLE: TOILET. FAUCETS, ETC.) 10. PLUMBING SYSTEM SHALL BE PRESSURE TESTED AND STERILIZED PER LANDLORD'S CRITERIA AND LOCAL AUTHORITY 11. UPON COMPUETION OF THE WORK, CONTRACTOR SHALL ENSURE THE PROPER WORKING ORDER OF THE SYSTEM (S) AND MAKE ANY ADJUSTMENTS AS REQUIRED. TABLE OF CONTENTS ANDAMEMLIZMACHIME MEP STANDAR14 E00.0 DIGINEERING SPECIFICATIONS ELECTI ICAO, E01.1 COL 1 E02.2 E03.1 EOM E04.2 £05.1 tW PROTECTION F02.1 SPRINKLER PLAN • SPECS F02.2 SPRINKLER PLAN IIIMNAIKAL 1101.1 MECHANICAL SPECIFICATIONS MO2.1 MECHANICAL PLAN MNlo2.2 MECHANICAL PLAN NO331 IECl1AIICAL WAD CADS AND DETAILS M03-2 MECHANICAL DETAILS 1104.1 ME131 INUIT SILUMORT RAN P01.1 FUMING S1FE IF CADONRS P02..1 PUMPING PLAN P03.1 !WHIM ISONEEKS a DETAILS 1C0.1 CONTROL M A C MANAMA DRA1 DISTRIBUTION SCHEDUIJE aowncIa CC. - aEewIon ROOM wt wewR+O. MME WNW ELECTRICAL SPECIFICATIONS ELECTRICAL POWER PLAN MORES marmemlu. POWER PLAN ELECIRCAL POWER PLAN ELECTRICAL WGNTING PLAN AND NOTES ELECIRICflL. LICKING PUN ELECTRI 11,. LIGHTING SCHEDULE ELECTRICAL DETAILS ELECT11IC L DETAILS ELECTRICAL. PANELS AND RISER DIAGRAM NEW • • • • • • • - • . 1t1iL� • NOM. • - - • • • A MI • • • • • • • / 111. ' -I1 • • • • • • • • • • 17 LET W cOI11ACTS FOS WM= INIPPLIED rA1lIIIAL. ma maw cfACT WOW PINICOMAIBIB AO' PLUMBING GENERAL NQTE$ b mu 11 IBIcT I nuImL r .S .DR I>' C Ml Mews - 1�! Ma /AE i1.-lPv_ R site MTV r ITEM VAIN OIIEA CU ENT DEUCE AT LNNOLOID$S vmur•w LtETER AT LAMOLCMOY W11#UAY COS AT LANDLORD'S NIENAY IERMCE ENTRANCE COOUIT(s) TO LEAK SPACE iRMCE OITRANC( RECE11(s) TO LEASE SPACE 277/490 MOLT PANEL(s) STEP ON. LAZE TRANSFOONERS t MOUNTING AOCEIIO OI (AS MUM) 120/200 MOL.T PNI . PANEL OISCOMECT SMTCN(ES) r HVAC DISCONNECT BUTCH Ir MANUAL MOTOR STARTNII(S) METER N LEASE SPACE C/T'S M LEASE SPACE Ors COT M LEASE SPACE MIMIC FOAMS NO LAMPS LD TOILET EmWIST FAN(S) ID RECEPTACLES II SALES AREA LD RECEPTACLES N MOM -SALES AREA to LIGHTING CONTROL SVIS III POOR rINIG AND COMM Fat SENSORMATIC EOLIPMENT FLOOR ROLES AND C0MS HOMER BONG FOR RounIG ORLL DELIVERY BU2zR Stow Coma N'M mum DATA CABLE CCODLITS ■ICI PLAL IELEPHOE CABLING AND .MAIMS SMOKE OETECNIR Si KIWI OR ',R4LY AM DUCT FL49 ALAN SYSi M .)9C s1rSTEM MMMK MIEN ameimcalmuor IIMPEINWPOIE COMM T AND 1 MMO STEM ACM SEANCE 1ElCFPTACLE PO>EN 1O OMEANISKAMER DUCT HEATER ME DAMPERS uNTAIANIIDA D (EATER 1EIIIMN .- FAN GUTNDE AN MEP w CONIEI15ATE 'NIPS AS -**.T s ELECTRICAL RESPONSIBILITY SCHEDULE L.•JDNAC FURNISHED BY EC EC PO49R INNING TO AMC EQUIPMENT EC MILER NINO TO 'tASNWAP' EC INSTALLED BY Lilac LNMLOIb Gahm LNOLG D CONTR. EC EC cc EC EC EC RE -USE N/A REMARKS Dam XIS IP • • • • • • • • MID OT EC BY TEL BY TEL 1W ROL BT AN: Call M AC QED BY EC OUTLET IN LD RV MC BY MK LOCAL AREA REQUIREMENTS SNORE EmMaN pN MOON oNN00E MOITOMl NO t o WORM ZONE VW NI D M S. D III G- O B 7. SPECIAL CUM HEIGHT KE+ u ns FIVE MIRE COASTAL PEOX MIRTY OTHERS. LE. METHANE. CARBON MONOXIDE. SOUND 3EI6I1I4E. ETC. OESCIIPIWIL .. . AR MLMI E ONTRACTOR COVet SEET AM BALANCE CONTRACTOR TO COPY TIPS FORm AND ATTACH AS COMER SHEET TO AR BALANCE REPORT AND WONT TO GENERAL CONTRACTOR 1 REPORT PREPARED BY NEBO OR AMC LICENSED CONTRACTOR? 2 ALL T� 219 FROM PHASE TO PHASE AS REQUIRED BY WV NAMEPLATE 3 ALL CURRENT WHIN N 10E S OM PHASE TO PHASE AS REQUIRED BY UNIT NAMEPLATE SPECIFICATIONS? 4 ALL INPUT AND OUTPUT AMR TENPERATu RES M11 1 ACCEPTAILILE RANK FOR THIS UNIT FOR EACH MOM AND STAGE? S LANDLORD SIAPPLED MEDIA (AM OR WATER) TENNERATURE WITHIN SX OF DE~S1G11 AND MEOW MON W1ETM 10E OF DESIpN? i ALL SUMP? OUFf1JSERS,. RETURN A/R GRILLES,, DUCT TRAVERSES AND STATIC PRESSURES WHIN 10(M* PERCENT OF DESIGN (PER LATEST REv1'9OM1)? 7 15 Was PROJECT SIGNED OFF N ISSUE OF A CONTROL KRIM MOH THE C01111ENTAL BUILBEC CONTROL SYSTEMS MIOIMITOIIIG CENTER AT (714) ass -.537 (SEE NOTE / PLEASE ACKUOMIEDiE UY NOM COMM MINE! M -11r- ter SEOUDICE tail S'EV►UIEIBCE MAL SEQUENCE one CIO o - aoo 1EQ L 11; THE AI R MNLMIC'IEC 4 OM NCTOR MtMT CONTACT C ONTINDIT L 111111.11116 COMM MEWS NDIII7O-'b awn *1 4) ) -M37 10 CAM 111E FLOP SENSOR K?*B?E . AT TIE OF 1111 A� NL/IIE INN M CONK ENA L ONIBIIG COMM STS MMOMr10MEC OILIER INN L. GENE II IE I11ML SMOVENCE OF TAE CONIIIIa. I1111KI . SAME Ipc 1141111 MILL ANL- COM NI COIWINCIOR 31111021111E IMAJINCE COolosclOrS ITEM PLUMBING RESPONSIBILITY SCHEDULE REMARKS PUNNING PMIILIIIES a 149! ORINNIO Mumma NO SEVER NO VENT PIPING MATER NEATER IN EI C Amor AND Cap 11110111 PIPING COMISATE OMAN PIPING SECOND COIO. IONIAN PIPING SFAS PPM NC SRAM PUMP DIANA ITAI MINI MOR NNW OEM OWL MUER m r 1 1 1 1 - T R IINNESIONS, INKANISIEMIR PIPING T sMIAMMIMit FURNISHED BY INSTALLED BY RE_ N/A LSDiC LAMOLaQ CONK COI< mut MUC K-USE XISTING PC PC NI PC Pc K PC Pc PC PC PC PC PC Pc MK PC MSC cc PC PC PC PC PC • • PAN IT MC IRONED IN IC HVAC RESPONSIBILITY SCHEDULE ITEM AM NNDLI1G UNITS AM HANDLING UNIT ACCESlONES RtLEF AIR/MANE -UP AR MOTOR OP HATED DAMS mar AM/NM -UP AIR MOTO OPERATED OAIIP P *MAIMS OUTIDE AM INTAKE HOOD Nair AIR FAN SUPPORTS FOIt Mill As • Noma Nil MANG SOK NO MIMING SOK taw OPERATED DAIMLERS NHU NIXING SOX MOTON OPERATED ONOVII ACTUATat CONDENSING LAMS CONDENSING UNIT ACCESSORIES CUM AID/OR 'STRUCTURAL SUPPORTS FOR COND. UNITS AS MUTED ROOMS WT t PAWN. MIRILATED Toe MOCK A arms LEVELING. V.A.V. SRS 1DMERATLIIE CONIIIOL SYSTEM T -STAT. COW BUSS. SENSORS SMOKE DEIECTOII(S) M KANN NO/at SUPPLY AIR DUCT OF moms NO gouts DALNSElls/a11,LES rat omouts VAAL FIRE GAINERS COMBMNAIION FOE/SMOKE DAMS LIM PIESSIME MOURN 1100/11EDI<MI PRESSI E DUCTIONt DUCT $,PDR1s SEISING BRACING 201E DAMPERS DUCT NEATEII(S) UNIT/SASESOAIEM NEAwN('S) TORII MOUSY FN1(s) MET Emma? OuCluCia NU OR 1100E CAP SECdOARY DRAM PAN COM ODISAN PUMP RE -USE N/A REMARKS Laic wage AO. molt LANELOD COMP OINDI XISTING AC Sc ID LD LD FURNISHED BY INSTALLED BY TIC IOC MC MC MMC MC MC MC TIC MC NIC MC MC MC MC MC MIC • • • • • - • • MING BY NC AIR BALANCE REPatT AS -SuGT 01tAIMNCS GC AM OR NEW CERTIFIED MC 324 FETE PROTECTION RESPONSIEILITY SCHEDULE PRAM PIE 011111111001111S AII.4111111.SE BNMMiM11 FUIWIS QED BY LlI1C LAItCIND COM - OPC ANC NIC INSTALLED IF! LAIOLOIII COM . OSIER -USE NC wt UPC N/A Ntimmes . RESPONSIBILITY SCHEDU LC - LA�L,aw TIC -* PC - COMIRCIOR .I - P� � ▪ - Wye =ONE MEIN OINSIONCIoN ac ININNER Oloinicion ClE01A.E LEGEND +� �c - �cIrR�IrT Z - �" PIS - Or - III! - �7� - 1OLIPME COmmiti11104 . - W141 IL usilLOO Is - OS SMMl11NO H B K CONSULTANTS, LTD 171 CHARRING CROSS DR S SUITE 18 WESTERVILLE, OHIO 43081 (614)$82 --1 X 1 . 99 oo co r O I- 0 A. •r IR :s r;; 0, d1 4--60 W sal rAi B i W IZ§ oW' •`° a N_ B • 5a ..t rB.W r W • i DO Wt 5. Nei Ihaii 1 :84711 Z W Z �i• '" K yy M�'rNsW� MiESC FIND ems CC 2 W r REVISIONS: ir •�.rw . .. _ • as ..... *s WIC IIIAT E tIEM DESIGNED SY: OM NI NY: DECKED If: z 0 . I-- 00 Z D CC 0I Z _ z zo ZO • oa J z W 0 cc -&--) o w 0 � W Ili Cc I- a - I~ • co 0 • r Z W :tit N LI% L o W pai Agia ....c .�.ZJ g oW Z� 0 W p r CZ "891 10 klzggiV M W r - 3P„: 11.. enc SPECIFICATIONS 11111IIIIING MOM E00.0 I- Z .. 0 -, 0 < Q. Y W 0. C7 < W 0 O IN z IN Z Pi) 0 Q 0 0 0 0 Q O a1Me -J r- W 0 oc o 0. NL v a ti VIo 10/16/03 RL.K / JS EDT /JS REK /*DB • F 'i • • S i 4 r m � go P" PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 28188 SCOPE: RELOCATION /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: sIC —t Cm LSD&C PROJECT #: 00043770 A/E PROJECT #: 0100688 032FA 03341/03132 �RONWT 0 REUM THESE ORAWINO$ AND SPECIFCATIONS WERE PREPARED FOR USE ON A SPECIFHI SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A OIfIERENT PROJECT SITE OR AT A LATER TIME. REUSE Of THESE ORAW1NOS AND SPECIFICATIONS, OR ANY REPRODUCTION THERE#. ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING BY UNITED _ STORE PLANNING, INC., D /R /A UMW STORE DESIGN AND CONSTRUCTION ("UDC". THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY Of LSDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT IT WRITTEN AOREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITI4OUT THE WRITTEN AUTHORIZATION Of THE LSDC ALL ORIGINALS OR REPRODUCTIONS Of THESE DRAWINGS AHD SPECIFICATKONS MUST PC RETURNED TO LSOC UPON COMPLETION OF THEIR INTENDED USE. UNLESS OTHERWISE AGREED BY THE LSDC. CO RIGHT NOE THE DRAWIN AND SPECIFICATIONS ARE COPTIBONTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 11103 KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF t/R0. THE PROTECTION INCLUDES, WITHOUT LIMITATION. THE OVERALL FORM, ARRANOEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION Of CONSTRUCTION, BUILDING SEIIURE, AND /OR MONETARY UABIUTY. Limited bra '1C LIMITED STORE PLANNING, INC. d /b /a STORE DESIGN & CONSTRUCTION Three Limited Parkway • Columbus, Ohio 43230 Telephone: 6144! 15.7000 • Fax: 614.415.7349 http://www.L.SDnC.LimitedBrands.com S • =a •A „w.. j i:.:.: -e� ... »..., 4 ' 7 4, 1 8=4' CI Xt.. _ t4<co> 0 00 00 c Z C7 I 0 s - V! • 0 OW- P 1� " ' j I;"i ' ep l I s i 6� 1 5 1! !S I II i i 1 i ft 1! d �� Q E �� I �� ! � F �6 �v � a�� 6� � �1� �$ s8 E _ E � � , � ` PE P A � .� � a , a i� eigao; I 1r n 'r 0 p. N ; ; 00; 10 N * N r * P P N N 711 Pg Pjf !!!!!li 1 iIIIIIII 1 1 1 1110Y111111 1 411 !ON Q gggY i E ; � p� � 1 , l 1 1�� � A 19 A AI I i �� as $, r N r IPTI I! P PR 1;,1 I Peel 1 1 1 I i INTO ip 14Ni ii! ill 6 IP igieq0 iidi ' Ip ! P i ; k 6 A � N r r 1+ r r , r P 9 1°1 s �id 1 9 I /Pi ! I l ib : I I 1;j111 I ;Pi Pi I I I NI ! ; tI ; P ! gag I I It 11 0 ; ob Ii Ei s i ;1! oi m I P! l l 1 014 11 41 111 ! /pi op pp 'IN pi 0 1! g Ti m 10 P r M N I ;' P r' F PA I N r milli 1 I a III i IiI gi i R a aka � ggg ' 4: 1 ! ii I / WWII: 1 IA! 1 1 5 5 :1 Ill / 41 1 1114111; I OH ;Agg Ppm' ViP ;35 2°) ep ii IT 1 N 1 1 PI 1:1 II :1; 111111 11111 11111111 ill ill 1 'if Al ''g A 1 1 1 lif I 1 P `+ P r P' to t i++ N ;- t o 1. MP 1 P 00i "T m 111 '! lii; ;yi 14:4 „$ 11 1 ph ; 1 x. ,I11,4:1 l'” 111" 1111141121 l ig p 1 ,1 igri 01; gri N 5{ '1' I III ' II: ogP i g loll irrtn P 1 1 lip P PPNI !OW! q! 1 ; ail:WIMP 1;1021 11 f" 1 1 1 °911 11 � 1r ya p 114" I TIP 1101 !lax 14 Id Rilei 11 111 11 1 1 15 - gs 111, iiqd 411 :14 1111 :P ipHi on:I Q liM P %II; 14i b !' 1 1 1, Q Pil;" 6 E r r M N f" 0 N N P N !o P fa 1; littt :! i tiii isids : Lel flap 54 011 ;J � ill Nips R '@ ! II plg x Ili g [ a r ig i 411 e aae a c-� a i ! aRSa L1 gl ei 1 '1 s YY i! I 11 ! 1 41 i 9f1 i s A ; 1 1 _I 191111 sh UP 11 II! 'I iii! I � Ili! i 'A: kU! �a{c M•u ON � E�S • I 10;" RIPPW PTS .p 1 l op! 1 1401 1 ER igRig fg 1R131;i i 'g"11; 5i gig; is h Ex pipsj eAffilq r k; VI a PE ego g 1 ill 1,-2 t .� ;4! IN* m 10 r isk Pa lip 4141 le;110 s!N ipo 1-000 111 101 1 ¢: a * A s dY ; bE N P 40! 10$ 1 c ip _ 4:1 :m ; 1111 111u ! 1: • N FF r 0 0 oPP R h am %hi NY 11 i ;II ;14i % ;1 l y ! I id N ! 1 eat i; : pi A dad' P' xim E 411 11 1 il Fil II Q 1 4 4; m i m 0/1 ,, IA N r r N r v pY ._ 1111-4 P r t t !g; 3 111 ff i A! 111: :; 11; GO � lil 4 1 ;Il :PA;°;04 1: 71! 1:i as i iiii! `� 2 �a�� • 1. THE AMREV I AT I ON LSDIIC . WHEREVER I T APPEARS IN THESE ELECTRICAL ORAWINGS. SHALL REFER TO 'LIMITED STORE DESIGN AND CONSTRUCTION.". ANY REFERENCE TO TENANT'S. LIMITED, OR FuRN I SHED BY ANY OF TIME ABOVE. REFERS TO LSDIIC . 2. THE CONTRACTOR FOR THOS * RK is REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF HIS SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR CLARITY. C I RCU 1 T I NG SHALL OE ' THRU -w I R I NG' WHERE AND WHENEVER POSSIBLE. 4. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT. 5. ALL RECEPTACLE CIRCUITS UP TO 100' -O" SHALL UTILIZE f12 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS FROM 101 -0" TO 150' --O' IN LENGTH SHALL UTILIZE 010 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS 151' -O' UP TO 250' -0" IN LENGTH SHALL UTILIZE /e CONDUCTORS MINIMUM. CIRCUIT ABOVE 251' -0' SHALL UTILIZE 06 CONDUCTORS MINIMUM. 6. PLACEMENT OF ALL RECEPTACLES IN THE 'SALES" AREA SHALL BE INTENTIONAL (I.E. - CENTERED ON COLUMNS. WALL FEATURES OR TIGHT TO CORNERS). IF THE RECEPTACLE IS NOT SHOWN IN A DESIRABLE LOCATION. FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH LSDDC'S PROJECT MANAGER PRIOR TO ROUGH -IN. 7. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 8. WHERE DRYWALL CEILINGS ARE USED IN THE "SALES" AREA. THE ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PALLS AS LOCATED ON PLANS. FIELD COORDINATE WITH LSDRC PROJECT MANAGER PRIOR TO ROUGH -IN TO AVOID ANY CONFLICTS. JUNCTION BOXES ABOVE LAY -IN CEILINGS ARE ACCEPTABLE. 9. EQUIPMENT LABELED "IFS ENCLOSURE' SHALL BE FURNISHED BY LSODC AND INSTALLED BY THE ELECTRICAL CONTRACTOR. REFER TO CODED NOTES. ELECTRICAL RESPONSIBILITY SCHEDULE. PANEL SCHEDULE AND POWER RISER DIAGRAM FOR SPECIFIC EQUIPMENT DESCRIPTION. 10. REFER TO SHEETS 'EOO.O E01.1. E02.1. E03.1. E03.3. E04.1. E04.2. E05.1 AND TC0.1 FOR DETAILS. SCHEDULES AND SPECIFICATIONS. 11. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE LANDLORD'S REPRESENTATIVE ON ANY FIRE ALARM SYSTEMS IN USE AT THE MALL AT THE TIME OF BID. IF THE FIRE ALARM SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR AND INCLUDE THE COST AS A SEPARATE LINE ITEM IN BID. NO ADDITIONAL MONIES SHALL BE AWARDED FOR TIE -IN REQUIREMENTS TO A LANDLORD'S FIRE ALARM SYSTEM THAT IS IN EXISTENCE AT THE TIME OF THE BID. WITHOUT A SEPARATE LINE ITEM FOR THE FIRE ALARM SYSTEM AT THE TIME OF THE BID. 12. THE ELECTRICAL CONTRACTOR MUST INCLUDE IN HIS BID TWO (2) HOURS OF STARTUP TIME FOR THE LIGHTING CONTROL SYSTEM. THE ELECTRICAL CONTRACTOR WILL BE REQUIRED TO REPAIR OR REPLACE COrPONENTS FOUND TO BE DEFECTIVE. THE ELECTRICAL CONTRACTOR MUST COORDINATE LIGHTING CONTROL STARTUP WITH CBCS /CIRCON CORPORATION CONTROLS STARTUP. FAILURE TO DO SO MAY REQUIRE THE ELECTRICAL CONTRACTOR TO RETURN TO THE JOB SITE TO PERFORM STARTUP AT A FUTURE DATE AT THE ELECTRICAL CONTRACTOR'S ORI1 EXPENSE. 13. ALL 24 VOLT COMMUNICATION AND /OR SENSOR WIRING ASSOCIATED WITH THE LSDNIC FURNISHED "CBCS /CIRCON" CONTROL SYSTEM SHALL BE PROVIDED BY LSONIC AND INSTALLED BY MECHANICAL CONTRACTOR. ALL FINAL CONNECTIONS SHALL BE BY CBCS /CIRCON. ALL WIRING AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCEINITH TIE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE. LOCAL CODE AND LANDLORD REQU I REIrENTS . 14. ANY PENETRATION THOROUGH THE ROOF OR WALL WITH CONTROL WIRING MUST BE SLEEVED IN A CONDUIT. POWER PLAN CONSTRUCTION NOTES 111 G SY1•f.1. • 4 MI T EMI sin d -4 coJ of m Q DESCRIPTION SECURITY DOMES SPEAKERS CEILING EXHAUST FAN DUPLEX RECEPT. W/ COVERPLATE QUAD. RECEPT. W COVERPLATE TELEPHONE OUTLET COMPUTER OUTLET MOTION SENSOR LIGHT SNITCH JUNCTION BOX MANUAL MOTOR STARTER STITCH MAGNETIC STARTER DISCONNECT SNITCH DELIVERY BUZZER DEUVERY BUZZER TRANSFORMER DELIVERY BUZZER PUSHBUTTON CEIUNG SMOKE DETECTOR DUCT SMOKE DETECTOR F IRE ALARM PULL STATION nRE ALARM SIGNAL PHASE MOTOR THREE PHASE MOTOR UGHHTMNG CONTACTOR TRAFFIC COUNTER DOOR CHIME DURLEX FLOOR RECEPT. WI COVERPLATE TWIST -LOCK RECEPTACLE MANUFACTURER ,It MODEL NUMBER SECURITY DOMES FURNISHED BY SENSORMATIC (FIRE RATED ENCLOSURES t CONDUIT F REO'D. BY CODE) BY E .C. SPEAKERS FUR 'D. By L.S.P. -1e GA. MIRE (AND FIRE RATED ENCLOSURES k CONDUIT F REOb. BY LOCAL CODE) BY E.C. GC160 . 120 VOLT. 1 PHASE. 11 S WATTS 20 Alp. I20 VOLT 20 Alp. 120 BOLT MATE RJ14C TELE. JACK III SALES AREA MO MIITTE RJI4C TELE. JACK N NON -SALES AREA. SEE FLOOR PLAN FOR MTG. HGT. HATE GROOVED CWRPLT. N SALES AREA AND MATE MOMNETED N NON -SALES AREA SEE FLOOR PLAN FOR MOUN1ING NOGHT INSTALLED AT 48" A.F.F. JUNCTION 80X. 4" X 4" X 2 1/8' DEEP MINIMUM NEMA 1 ENCLOSURE FULL VOLTAGE STARTER WI A NEMA 1 ENCLOSURE. SIZE 1 MINIMUM HEAVY DUTY. FUSE AND NON- FUSELE SEE FLOOR PLAN FOR MOUNTING HEIGHT TRANSFORMER AT e' -o" A.F.F. SYSTEM CONNECTED DUCT MOUNTED IONIZATION TYPE SMOKE DETECTOR COMPLETE NTH SWUNG TUBES SYSTEM CONNECTED DOUBLE ACTION MANUAL FIRE ALIAS PULL STATION AT 48` A.F.F. SYSTEM CONNECTED RECESSED AUDIO/VISUAL UNIT AT A.F.F. ELECTRICALLY ENERGIZED AND HELD LIGHTING CONTACTOR IN A NEMA 1 ENCLOSURE (FOR FUTURE) E -Z TONE SECURITY DOOR CHIME 'CH ITK13` 20 AMP. 120 VOLT DREAM STEAMER - (FURNISHED BY LSD&C) POWER REFERENCE SCHEDULE • REMARKS INA) INA1 MAI CHM INA) DIM INA) C P1 RECEPTACLES AND COVERPLATES DESIGNATED "SF" SHALL BE ALMOND IN COLOR. FURNISHED BY LSDRaC AND INSTALLED BY ELECTRICAL CONTRACTOR WHERE SHOWN ON PLANS IN THE UNDERSIDE OF THE STOREFRONT SOFFIT W I THH THE 4" SIDE PARALLEL TO THE STOREFRONT GLASS. FIELD VERIFY EXACT LOCATION OF ALL RECEPTACLES WITH LSOBC'S PROJECT MANAGER PRIOR TO ROUGH-IN OF RECEPTACLE BOXES. (5) RECEPTACLES AND COVERPLATES DESIGNATED "C" SHALL BE ALMOND IN COLOR. FURNISHED BY LSODC AND INSTALLED BY ELECTRICAL CONTRACTOR HORIZONTALLY CENTERED IN BASE. FIELD COORDINATE WITH CABINET INSTALLER BEFORE CABINETS ARE INSTALLED TO AVOID CONSTRUCTION DELAYS. RECEPTACLES AND COVERPLATES DESIGNATED "W` SHALL BE ALMOND IN COLOR. FURNISHED BY LSDIRC AND INSTALLED BY ELECTRICAL CONTRACTOR. MOUNT AT 18" A.F.F. EXCEPT AS NOTED ON PLAN. FIELD VERIFY EXACT LOCATION OF ALL RECEPTACLES WITH LSDINC'S PROJECT MANAGER PRIOR TO ROUGHS -IN OF RECEPTACLE BOWES. RECEPTACLES AND COVERPLATES IN 'NON - SALES" SHALL BE *IITE IN COLOR. FURNISHED BY LSOrC AND INSTALLED BY ELECTRICAL CONTRACTOR. MOUNT ALL RECEPTACLES AT 113" A.F.F. EXCEPT AS NOTED ON FLOOR PLAN. FIELD VERIFY EXACT LOCATION OF ALL RECEPTACLES WI TM LSDOC' S PROJECT MMINAC,`ER PRIOR TO ROUGH - I N OF RECEPTACLE BOXES. TYPICAL OF ALL RECEPTACLES IN `RECEIVING' AND "H.C. LAV . " AREAS. UNLESS NOTED OTIERIN I SE . P4 INSTALL A DELIVERY BUZZER SYSTEM AS SHOWN ON DRAB I NGS _ LSDO C SHALL PROM I DE A COMPLETE EDIMAROS DEL I VERY BUZZER SYSTEM COMPLETE WITH TRANSFORMER. BUZZERS. LOUVERED COVERPLATES AND PUSHBUTTON (WEATHERPROOF FOR OUTSIDE LOCATIONS). THE ELECTR I CAL CONTRACTOR SHALL PROV I DE ALL NECESSARY JUST I OI B OWES. CONDUIT AND WIRE TO COMPLETELY INSTALL THE DELIVERY BUZZER SYSTEM. REFER TO `DEL I VERY BUZZER SCHEMATIC" ON SHEET E04.1 FOR ADDITIONAL I NF'ORm AT I ON . ALL JUNCTION BOXES SHALL BE MOUNTED VERTICALLY. CD TELEPHONE OUTLET IN WALL. ELECTR I CAL CONTRACTOR TO RUI A 3/4` EMPTY CONDOiT. WITH PULLWIRE. BACK TO TELEPHOIE/DATA SECTION OF 1 FS ENCLOSURE. TELEPHONE W 1 RE AND ORJ 11 C JAN( FOR TAR) LINE TELEPHONE BY OTHERS. SEE FLOOR PLAN FOR MOUNTING HE I CHAT . REFER TO "TELEPHQIEACO PUTER SYSTEM SOCRATIC" ON SHEET E04.1 FOR ADDITIONAL I NIFQRYAT I OI _ EXTEND 1" TELEPHHKRE J I T FROM SERVICE ENTRANCE AT DEMISING WILL TO TELEPHONE/DATA SECTION OF IFS ENQOS RiE . 4` X 4' ,IUCT I ON1 BOX IN MILL. WITH COrEIRWLATE . INSTALLED AT 7' 1" A.F.F. FOR SOUND SYSTEM. INSTALL A 3/4" CONDJ I T . WITH PUJLLW I RE . UP IN WALL TO A 4 "1E4" JU NCT I ON BOX ABOVE CEILING. INSTALL OUAORAPLEX RECEPTACLE AT 7' -0' A _ F . F . ADJACENT TO JU CT ION 110K _ REFER TO "SOLNAD SYSTEM INSTALLATION DETAIL" ON SHEET EM .1 FOR ADO I T 1 OSAL I NFONNAT ION. ELECTRICAL aImTRACTOR IS TO Flail l 94 ND 1 NSTALL ALL CI CU • T AND JUNNCT ION BONES. ELECTRICAL CONTRACTOR SHALL MINI 9, AND INSTALL A 3/4" COHDJ 1 T R1 TM PU LLRI RE MN HNAC SECTION OF IFS DCL0su E I)P TO QIeIIE CE I L I NG . COMM NATE ENACT REOJ 1 CEMENTS RI TM MEC H N1 I E•AL CONTRACTOR _ WIN LNG FIJDI19ED NO I'STALLED BY ME0•01CAL CONTRACTOR 20 MP. 120 VOL T S I NRr .E PHASE ISOLATED DEDICATED C I IMQRJ I T . TNO i1R GROUND. sINIICLE 3/43/4" CONDUIT S HOE TO I FS A ENCL /RE FCR CO PuTER TERNI Ir11L _ DO NOT SNOW MAW PART NSF THIS cumuli VI TN NR OTHER Ul.L u C I IMO I Ts. Wan RECEPTACLES AT 311" A. F .F _ 10 INDT110m. F ICED VERIFY EXACT LOCAT Tar OF ERECEPTAQ .E M111 LSDC M*DJECT MINCER PRAM 10 ELECTRICAL I1CAD1 -HIT. WE* 10 SYSTEM SCNEWAT HC" a lEET EINT_ 1 FOR 1 Ti. a IN O TAT IA. B X 8" X 4" PULLBOX. WITH COVERPLATE. ABOVE CEILING ON WALL ABOVE MANAGER'S DESK AREA. INSTALL 1" CONDUIT. WITH PULLWIRE. FROM PUJLLBOX TO A 4" x 4" JUNCTION BOX IN WALL AT 36" A.F.F. TO BOTTOM FOR COMPUTER TERMINAL. I NSTALL 1 CONDJ I T. WITH PUL LW I RE . FROM PUL LBOX ABOVE MANAGER'S DESK AREA TO CASI#RAP COUNTER IN "SALES" AREA. DATA CABLING BY OTHERS. REFER TO "CASHORAPeBACKARAP PLAN' AND "TELEPHONE/COMPUTER SYSTEM SCHEMATIC ON SHEETS E04.1 AND E04.2 FOR ADDITIONAL I NFORMAT I ON . ELECTRICAL CONTRACTOR IS TO FURIN I SH AND INSTALL ALL C CU I T AND JUNNCT I ON BOXES. H� DATA OUTLET IN A 2" x 4" JUNCTION BOX FOR COMPUTER TERMINAL AT 36" A.F.F. TO BOTTOM. ELECTRICAL CONTRACTOR SHALL INSTALL 3/4" CONDUIT. WITH PULLWIRE. TO W.R. CONTROLS ENCLOSURE. TELEPHONE CABLE. DATA CABLE. AND 0RJ11C JACK BY OTHERS. FIELD VERIFY EXACT LOCATION WITH LS0MC'S PROJECT MANAGER PRIOR TO ROUGH.-4N. REFER TO 'TELEPHONE/COMPUTER SYSTEM SCIEWT I C" ON SHEET E04.1 FOR ADDITIONAL I NFORNT m ONm . H 1� ELECTR 1 CAL CONTRACTOR SHALL FORM I SH AND INSTALL 2" X 4" JUNCT I ON BOX AT 48" A.F.F. WITH FACE FLUSH TO DRYWALL AND 3/4" ,. J I T WITH PULLW I RE UP IN WALL TO ABOVE CEILING FOR SENSOR. COORDINATE EXACT REQUIREMENTS WITH MECIAN I CAL CONTRACTOR. ELECTR I CAL CONTRACTOR SHALL VERIFY EXACT LOCAT I CON WITH LSOIC PROJECT MANAGER PRIOR TO - I N . IFS ENp.06URE FURNISHED BY LS= AND INSTALLED BY ELECTRICAL CONTRACTOR. REFER TO POKER RISER ON SHEET E05.1 FOR ADDITIONAL INFORMATION. FOUR REGISTER CASH ARAP/BACIiMRAP COUNTER WITH FUTURE SEASONAL CASARRAP . ELECTRICAL CONTRACTOR TO PERFORM ALL MOK AS I IND I CATED IN THE 'CASHNRAP/GOUNTER DETAIL" AS SHORN ON SHEET E04.2. REFER TO ARI(H I TECTURAL FLOOR PLANS FOR EXACT ROUGH~ - I N I NFORMMT I OI . INSTALL A 120 VOLT LIGHT/RECEPTACLE AT UNIT WIRED TO CIRCUIT AS INDICATED. L I G HT/RECEPTACLE Fu NN 19ED BY LSDrC AND INSTALLED BY THE ELECTRICAL CONTRACTOR_ REFER TO SKEET (04.1 FOR ADD 1 T IONiAL INFORMATION. (ELECTRICAL CONTRACTOR SHALL VERIFY IN FIELD EXISTENCE OF A RECEPTACLE WITHIN 100' -0" OF UI I T. IF ONE IS PRESENT. DO NOT INSTALL L I GHT/RECEPTACLE UNLESS REOU I RED BY LANDLORD OR LOCAL CODES.) 5 DUET MOUNTED SMOKE DETECTOR FURNISHED BY LSDIC AND INSTALLED BY THE MECHANICAL CONTRACTOR. MEDIAN I CAL CONTRACTOR TO Rum CONTR. WIRING TO POINT SPECIFIED BY CWC I BOOT CONTROLS. CBCSr/C 1 IACONI TO man FINIAL CONECT I ON S . ENCLOSURE WI TH SENSOR AT IC POW/ PACK NND ISOLATED HraMOUJtD TYPE OuPLEX RECEPTACLE AMOUNTED Cu vERT 1 CAL MX OF SOFF 1 T IRBDME CEILING G R 1 D. CODED' NATE SENS T;C FEOUENCY W 1 TH ADJACENT TENANT SEPISORI er IC SYSTEMS. SEE SENSONTAT IC DETAIL ON SHEET E04.2. (PAINT MASSE TO TATOm CE 1L mg- ) 115, SENSOIrma IC SYSTEM/ PON I COED M LSENI C . REFER TO SENSORAT I C DETAIL ON 9EE T EO4.2 FOR ELECTRICAL 'S MESPO6IS IL MEOMN IC,AL CONTRACTOR SHALL FIAT' S H NC INSTALL AIR DEVICE TO OE MD FOR ACCESS TO Eau IgEIUT LOCATED ABOVE THE CE IL IrmC. TM I S CONTRACTOR SHALL WE IIESPONSIOLE TO ENSURE RAT A Ml Ir 1MM ILINOISTIRCTED FEE APNEA OF 3 -FEET "CRT 1CALLY me 2 -1FEET INOR 1ZOITTALux IN ALL DIRECT IONS MOUND ESNITNIENRt IS IA LAMMED '10 AL.LOR FOR INSTAL,LATKIN MD NAHNITENTIOX OF ( HHAEMT. IF THIS FREE _'A Co min D OBTAINED. CTKT 1!E LEC PRICY IMINIMER NTIM2HATIELy. OESTODONI D'CEPT/POI . aF 1. laimMED AT 42" A.F.F. GOOPIDIN ATE EIN CT LOCAT Oar IN 1N LIDC'S MOW MiMRDR MGR 110 Ra�lpt`rMM. CD) 30 AMP. 250 VOLT. 3 PHASE TWIST -LOUT( RECEPTACLE AND STAINLESS STEEL COVERPLATE FURN I SHEED BY LSDINC. INSTALLED BY ELECTRICAL CONTRACTOR FOR DREAM STEAMER. LOCATE RECEPTACLE AT 18" A.F.F. AS 9IOR1l4 ON SHEET PO3.1. RECEPTACLES AND COVERPLATES WITHIN SHON WINDOW SHALL BE ALMOND IN COLOR. FURNISHED BY LSO LC AND INSTALLED BY ELECTRICAL CONTRACTOR. INSTALL ALL RECEPTACLES HORIZONTALLY 8" ABOVE PLATFORM TO CENTER AND CENTERED SIDE - TO - SIDE CF SIDE MALL. EXCEPT AS NOTED OTHERWISE ON FLOOR PLAN. FIELD VERIFY EXACT LOCATION OF ALL RECEPTACLES WITH LSDrc'S PROJECT MANAGER PRIOR TO ROUGH - I N OF RECEPTACLE BOWES. 4f3/ JUNCTION BOX FOR MOTORIZED STORE GRILLE. 120 VOLT SINGLE PHASE. RUN 2012 T11 1 AND 1012 GROUND IN A 3/4" CONDU I T FROM A 20 AMP. SINGLE POLE 'AC' TOGGLE SWITCH. FURN I SHED BY LSDIMC AND INSTALLED BY ELECTRICAL CONTRACTOR TO A 20A-1P BREAKER IN PANEL. PROVIDE ANY NECESSARY WIRING TO GRILLE CONTROL STAT 1 016 AS REQUIRED INCLUDING ANY SPECIAL INTERLOCKS REQUIRED BY LANDLORD. MAKE ALL FINAL ADJUSTMENTS TO THE LIMIT SWITCHES. KEY OPERATED SWITCHES SHALL BE PROVIDED BY LSDIIC AND INSTALLED BY THE ELECTRICAL CONTRACTOR AT 111 A.F.F. ANND SHALL BE FULLY RECESSED IN WALL AT STOREFRONT OR IN COLUMN. REFER TO ARCHITECTURAL PLANTS FOR LOCATION AND MOUNT 1 NG DETAILS OF KEY STITCH. TCHr. RECESS BONES FOR KEY SWITCH. EMERGENCY RELEASE Al INTERLOCK SNITCH INTO COLUMN DEEP ENOUGH TO ASSUIRE CUSTOM COVERPLATES. FUNRN I SHED BY LWOW. WILL FIT FLUSH AGAINST THE COLUMN. 20A RATED RECEPTACLE • 42" FOR MICR NAVE. IF PLAN LOCATION IS NOT ACCEPTABLE. I IRED I ATELY CONTACT LSOROyC PROJECT mA NAGGER FOR DIRECT H 20A RATED RECEPTACLE • 15" FOR REFRIGERATOR. IF PLAN LOCATION IS NOT ACCEPTABLE. IMMEDIATELY CONTACT LSD•C PROJECT MANAGER FOR DIRECTION. €t° 120 VOLT. 1 PHASE POWER JUNCTION BOX FOR CONTROL POWER FUIRN I SHED AND INSTALLED BY ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR 1 S TO mot ALL FINAL 120 VOLT CONNECTIONS. POWER PLAN CODED NOTES OP A H 8 K CONSULTANTS. LTD 171 CHARRING CROSS DR S SUITE 18 WESTERVILLE, OHIO 43081 (614)882-1199 co oo 0 0 DATE ISSUE& DESIGNED ST CHECKED iJFIR:� c,-' 1 :I TO z 0 . ' - - ZD cc 0 I- _z z � Q � Z 72 5 CC ET) 0 III (1) 0w W � J 511t1g 4;11 i51:12 gg:/11 snaaV.i W hvg!ii EW :: s Z W W1WO AgiR N`3 =M� - eEY 0 v.. Og ~ 3 � poit : . "c'o" 3 a MM (a1� Q .A ' � r� qW 5 0414 li 0._ 4. .► __ m g....41 �ti 4t Q w W Z�Y ` s W «i �t iig i5445.r. 1-"ft .�ai�t�o�t W -.dig 40Eld REVISIONS: esema sF imow . . 11111110111 ' - C N 0 0 E 0 03 ax m 0. E :a ELECTRICAL POWER PLAN NOTES •I L:u 1141111113t E02.1 " Z d CZ d SC us o o. 0 La 0 Nz n N; z � 0 0 0 'Sz .. N! ._j r- W •• W fl v U a. U W h VfHIJ 10/16/03 RUC EDT REK it f • i 4 V • • • 4 A i I 1 4 L A PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: RELOCATION /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 A/E PROJECT #: 0100688 032FA 03341/03132 TH(S DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTNOMZED IN WRITING BY NITED U STORE PLANNING. INC.. D /B /A UNITED STORE DES KIN AND CONSTRUCTION ( "LSDC"). THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF LSDC AND SHALL NOT SE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH UDC. NO REPRODUCTION Or THESE DRAWINGS AND SPECIFICATIONS SMALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION Of THE LSDC. ALL ORIOINALS OR REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST BE RETURNED TO UDC UPON COMPLETION OF THEIR INTENDED USE, UNLESS OTHERWISE AGREED SY THE LSOC, garieoAT THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 Of THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 19901 KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1550, THE PROTECTION INCLUDES, WITHOUT UMITATION. THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION OF CONSTRUCTION, BUNAINO SEIZURE, AND /OR MONETARY UABIUTY. Limited brands LIMITED STORE PLANNING, INC. d /b /a STORE DESIGN & CONSTRUCTION Three Limited Parkway • Columbus, Ohio 43230 Telephone: 614.415.7000 Fax: 614.415.7349 http://www.LSDnCilmitedBrands.com 0 w o E2 1 Z in 1 t • • 4 11, 1 8 MATCH 1 LINE MATCH LINE .s. .4110 Low U Pi ; PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: RELOCATION /DOWNSIZE PACKAGE: I DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 AVE PROJECT #: 0100688 032FA 03341/03132 PROHIlITION ON REUSEI THESE DOMINOS AND SPECIFICATIONS WERE PREPARED FOR USE ON A arcane SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF. ON ANOTHER PROJECT IS PROHIOITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN wRM#10 IY LIMITED STORE PLANNING, INC., D /I /A UNITED STORE DESIGN AND CONSTRUCTION ('UDC' ). THESE NAVAHOS AND SPECIFICATION: ARE THE PROPERTY OF LSDC AND SHALL NOT SE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT NY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION Of THESE DRAWINGS AND SPECIFICATIONS SHALL OE MADE WITHOUT TILE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS 011 REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST RE RETURNED TO UDC UPON COMPLETION OF THEM INTENDED USE. UNLESS OTHERWISE AGREED BY THE LSOC. T Honer HESS DRAWINGS AND SPECIFICATIONS ARE COrYRI:HTED AND SMUT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. t02 OF THE COPYRIGHT ACT. 17 U.S.C. AS AMENDED DOWSER tfl0s KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 11110. THE PROTECTION INCLUDES, WITHOUT UMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES. AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION OF CONSTRUCTION. BUILDING SEIZURE. AND /OR MONETARY UAMUTY. limited braids LIMITED STORE PLANNING, INC. d /b /a STORE DESIGN & CONSTRUCTION Three Limited Parkway • Columbus, Ohio 43230 Telephone: 614.415.7000 - Fax: 614.415.7344 http:/, iwww.L.SfDnC.L_imitedBrands.com I M M O* IE an O ` a a0 Z Z •0 � 0 tra O y O d 7O - Q ...r e:ae.mr :u..:acc .uwe.•� 11 MP 1 t • • 4 11, 1 8 MATCH 1 LINE MATCH LINE .s. .4110 Low U Pi ; PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: RELOCATION /DOWNSIZE PACKAGE: I DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 AVE PROJECT #: 0100688 032FA 03341/03132 PROHIlITION ON REUSEI THESE DOMINOS AND SPECIFICATIONS WERE PREPARED FOR USE ON A arcane SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF. ON ANOTHER PROJECT IS PROHIOITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN wRM#10 IY LIMITED STORE PLANNING, INC., D /I /A UNITED STORE DESIGN AND CONSTRUCTION ('UDC' ). THESE NAVAHOS AND SPECIFICATION: ARE THE PROPERTY OF LSDC AND SHALL NOT SE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT NY WRITTEN AGREEMENT WITH LSDC. NO REPRODUCTION Of THESE DRAWINGS AND SPECIFICATIONS SHALL OE MADE WITHOUT TILE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS 011 REPRODUCTIONS OF THESE DRAWINGS AND SPECIFICATIONS MUST RE RETURNED TO UDC UPON COMPLETION OF THEM INTENDED USE. UNLESS OTHERWISE AGREED BY THE LSOC. T Honer HESS DRAWINGS AND SPECIFICATIONS ARE COrYRI:HTED AND SMUT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. t02 OF THE COPYRIGHT ACT. 17 U.S.C. AS AMENDED DOWSER tfl0s KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 11110. THE PROTECTION INCLUDES, WITHOUT UMITATION, THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES. AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND SPECIFICATIONS MAY RESULT IN CESSATION OF CONSTRUCTION. BUILDING SEIZURE. AND /OR MONETARY UAMUTY. limited braids LIMITED STORE PLANNING, INC. d /b /a STORE DESIGN & CONSTRUCTION Three Limited Parkway • Columbus, Ohio 43230 Telephone: 614.415.7000 - Fax: 614.415.7344 http:/, iwww.L.SfDnC.L_imitedBrands.com I M M O* IE an O ` a a0 Z Z •0 � 0 tra O y O d 7O - Q ...r e:ae.mr :u..:acc .uwe.•� THE ABBREVIATION LSO6C, WHEREVER I T APPEARS I N THESE ELECTRICAL DRAWINGS, SHALL REFER TO "LIMITED STORE DESIGN AND CONSTRUCTION'. ANY REFERENCE TO TENANT'S, LIMITED. OR FURNISHED BY ANY OF THE ABOVE. REFER TO LSO6C 2. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF HIS WORK AND THE WORK OF HIS SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTORS' RESPONSIBILITY TO PROVIDE HIS SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS . 3. LIGHTING SHALL 8E CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE 'THRU- WIRING" TYPE WHERE AND WHENEVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. LIGHTING FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE 'TNRU- WIRING ANY RELATED COSTS FOR MULTIPLE CONNECTIONS SHALL BE INCLUDED IN BID. 4. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATIONS AND QUANTITIES OF LIGHTING FIXTURES. 5. ELECTRICAL CONTRACTOR'S BID SHALL INCLUDE THE INSTALLATION OF ALL LIGHT FIXTURES AND ASSOCIATED LAMPS FURNISHED BY LSDRC. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO ENSURE THE ADJUSTIBILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND AIM THEM. LIGHT FIXTURE SPECIFICATIONS MAY VARY. IF THIS IS THE CASE. THE CONTRACTOR IS TO CALL 'LSDRC' FOR EXACT SPECIFICATIONS OF LIGHT FIXTURES. IF CEILING SYSTEMS ARE FIRE RATED. CONTRACTOR IS TO CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH LIGHTING SUPPLIER. 6. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES, ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE WITH BATTERY BACK -UP (120/277 VOLT INPUT). (INSTALL A CENTRAL BATTERY SYSTEM WHERE THE USE OF INDIVIDUAL BATTERY UNITS ARE PROHIBITED BY LOCAL CODES.) CLOSELY COORDINATE INSTALLATION WITH LSDK' S PROJECT MANAGER. LIGHTING PLAN CONSTRUCTION NOTES 7. ALL LIGHTING CIRCUITS UP TO 100' -0" IN LENGTH SHALL UTILIZE /12 CONDUCTORS MINIMUM. ALL LIGHTING CIRCUITS FROM 101' -O" TO 15O' -0" IN LENGTH SHALL UTILIZE /10 CONDUCTORS MINIMUM. ALL LIGHTING CIRCUITS 151' -0' UP TO 250' -0" IN LENGTH SHALL UTILIZE 08 CONDUCTORS MINIMUM. CIRCUITS ABOVE 251' -0" I N LENGTH SHALL UTILIZE /6 CONDUCTORS MINIMUM. 8. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COIPLETE AND OPERATIONAL SYSTEM. O. WHERE DRYWALL CEILINGS ARE USED IN THE 'SALES" AREA. ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCU!TS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. FIELD COORDINATE WITH LSDI>IC PROJECT MANAGER PRIOR TO ROUGH -IN TO AVOID ANY CONFLICTS. JUNCTION BOXES ABOVE LAY -IN CEILINGS ARE ACCEPTABLE. 10. EXIT / EMERGENCY LIGHTS AT STOREFRONT ARE FD BE CEILING MOUNTED AND CENTERED OVER OPENING (TYPICAL U.N.Q.). ExIT/EMERGENCY LIGHTS AT DOOR TO 'NON- SALES" SHALL BE CENTERED ON WALL ABOVE DOOR. FIELD VERIFY EXACT LOCATION AND MOUNTING HEIGHT WITH LSD&C'S PROJECT MANAGER PRIOR TO ROUGH -IN. 11. LIGHT FIXTURES INDICATED WITH SHADING WILL BE ZONE "B" STOCKING LEVEL. • LI ELECTRICAL CONTRACTOR IS TO INSTALL OCCUPANCY MOTION SENSOR SWITCH FURNISHED BY LSOBC FOR CONTROL OF ROOM LIGHTS AS SHOWN. ELECTRICAL CONTRACTOR SHALL SET SWITCH FOR 15 MINUTES. MOTION SENSOR SWITCHES TO BE DESIGNATED 'MS' ON FLOOR PLAN. L2 FIXTURE MOUNTED ON DRYWALL CEILING ON MANAGER'S OFFICE AND /OR RESTROOM. L3 PROVIDE JUNCTION BOX. TOGGLE DISCONNECT SWITCH IN NON- VISIBLE LOCATION, AND FINAL CONNECTION FOR 120 VOLT SIGN FURNISHED BY LSO6C. COORDINATE EXACT LOCATIONS WITH LSO6C PROJECT MANAGER. SIGN IS PROVIDED WITH INTERNAL GROUND FAULT PROTECTION BY SIGN MANUFACTURER PER N.E.C. ARTICLE 800 -23b. (REUSE EXISTING JUNCTION BOX AND CONDUIT INTO SPACE IF ALREADY INSTALLED. VERIFY IN FIELD EXACT LOCATION ON CANOPY). L4 FIXTURES SHOWN DASHED ARE MOUNTED IN THE TOP OF CABINETS AND FIXTURES SHOWN SOLID ARE MOUNTED IN LIGHT COVE. REFER TO ARCHITECTURAL PLANS FOR ACTUAL MOUNTING INSTRUCTIONS. `C:/ IN-LINE EXHAUST FAN. 120V. SEE MECHANICAL DRAWINGS AND COORDINATE EXACT LOCATION INCLUDING ITS SWITCHING SYSTEM CONNECTION. REFERENCE DETAILS ON SHEET E04.1. M LIGHTING PLAN CODED NOTES D (2) sir (3) "rr 2 • Tr ) 0 . ' Ts (r) mum NA, seraraction ����►:����iiii W 11111111EXIMENANDMENZEIS If Irin ii�il \i � 1111111111111 1,11 1 MEM PRI 1�7 ►��r� � Li =�g.�1 ■ ICI �����111� z ��l /I�� I�IM��IL�Ji�i��i� �1�1�r�lIA ImaI i�/l■�p :i�l�l �:� �i.a� ��I�1 ■ ■�1�' ■ ■■�If,��� i:� .' �,f�. �� I\�■�`�i�lE�".� Il�■f'E�`, 111\ immiginigraggaz 1: IIILliV Limes 11110 Till grar rei 1111111311.Mill: BT IF 111111 111101BEFAINal iscordatintair A-20 111 1A l'aNIMERIEN ELECTRICAL LIGHTING PLAN I r • lr4 �A H 8 K CONSULTANTS. LTD 171 CHARRING CROSS DR S SUITE 18 WESTERVILLE. OHIO 43081 (614)882-1199 oo oo a W a. C;d7r; nt� ii ,lI k .4wttttltlMttttW1J Lanstut tltl.ttlK�" cf) - 0 -- 0 DALE ISSUE& CONNED IT: R OR O IT: p ECRED IT: Y"1NIRtlMYll lMtttR11t7M. MOW: 1,1 11:/1 * t , Ft. +n— ryn +t .NI � ' z O . 1-- 00 0 z z 2 z0 J °6 0- z W0 cc 0 W W REVISIONS: • .slaws imumen w . co wet Q 0 Cl) .0 0 CD !0 - v a� E J m N ti.. t I-- .r- E03.1 O U; C on t0 t3 4. E J (5 C U) � Pr) N .— 00 M M 0 N z O Z M 0 J 0 0 < .. U si O —J t~ W ••W m ar a. Z a. t] VI 10/16/03 RLK EDT REK ELECTRICAL LIGHTING PLAN AND NOTES W Oto w M• I • r i 4 • s m 0 0 ArriP NE 714 w PROJECT INFORMATION: THE LIMITED SOUTHCENTER 833 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: RELOCATION /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 A/E PROJECT #: 0100688 032FA 03341/03132 PRQH1rITiod Qd KW3E THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED root USE ON A mono SITE CONTEMPORANEOUSLY WITH THEIR ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DI►►ERENT PROJECT SITE OR AT A LATER TIME REUSE Of THESE DRAWINDS AND SPECIFICATIONS. DR ANY REPRODUCTION THEREOF. ON ANOTHER PROJECT IS PROHIBITED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRITING DT UNITED STORE PLANNINO, INC.. 0 /11/A LIMITED STORE DESIGN AND CONSTRUCTION ruoc'y. THESE DRAWINOS AND SPECIFICATIONS ARE THE PROPERTY Or LSOC AND SHALL NOT DE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AOREEMENT WITH LSDC. NO REPRODUCTION OF THESE DRAWINGS AND SPECIFICATIONS SHALL DE MADE WITHOUT THE WRITTEN AUTHORIZATION Of THE LSDC AU. ORIGINALS OR REPRODUCTIONS Of THESE DRAWINOS AND SPECIFICATIONS MUST DE RETURNED TO LSOC UPON COMPLETION Of THEIR INTENDED USE. UNLESS OTHERWISE AGREED BY THE LSDC. COPYRIGHT NOTICFI THESE DRAWINGS AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER SEC. 102 Of THE COPYRIGHT ACT. 17 U.S.C. AS AMENDED DECEMBER 1900c KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 19110. THE PROTECTION INCLUDES. WITHOUT UMITATION, THE OVERALL FORM. ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS Of THE DESIGN. UNDER SUCH PROTECTION. UNAUTHORI2ED USE Of THESE DRAWINOS AND SPECIFICATIONS MAY RESULT IN CESSATION Of CONSTRUCTION. BUILDING SEIZURE, AND /OR MONETARY UADIUTY. Limited bra ids LIMITED STORE PLANNING, INC. d /b /a STORE DESIGN & CONSTRUCTION Three Limited Parkway . Columbus, Ohio 43230 Telephone: 614.415.7000 Fax: 614.415.7349 http://www.t..SDnC.Limitederands.com to 0 • H 8 K CONSULTANTS. LTD 171 CHARRING CROSS DR S SUITE 18 WESTERVILLE. OHIO 43081 (814)882 -1199 �.ww..w•tlt' +w7+w.f f;+nlN.(li...:y:a fti t REVISIONS: maim w OVATE MIA MINI it CHECKED IT: 0 t- cD G 10/16/03 RLK EDT REK LIMITED • • • • SYMBOL FW HI 4` DIAMETER RECESSED QUARTZ HALOGEN DOV OUGHT INTEGRAL • H3 ELECTRONIC TRANSFORMER, CLEAR CONE. CHROME REMODEL HOUSING 6' BARE LAMP FLUORESCENT • L5 STRIP. ELECTRONIC LOW BALLAST FACTOR BALLAST, 1 LAIN' IN SECTION a' BARE LAMP FLUORESCENT STRIP. ELECTRONIC LOW BALLAST FACTOR BALLAST. 1 LAMP IN • L6 SECTION. (2) 4' SECTIONS TANDEM MIRED ON ONE BALLAST, QUICK CONNECT PLUGS 12' BARE LAMP FLLIORESCDO STRIP. ELECTRONIC LOW BALLAST FACTOR BALLAST. 1 LAMP N • L7 SECTION. (3) 4' SECTIONS TANDEM MIRED ON ONE BALLAST, QUICK CONNECT PLUGS • W 3' LINEAR FLUORESCENT IN J3 FIXURE„ ELECTRONIC BALI AST, T LAMP IN SECTION 4' LINEAR FLUORESCENT IN COVE J4 FIXTURE. ELECTRONIC BALLAST. 1 LAMP IN SECTION 6' LINEAR FLUORESCENT M COVE FIXTURE. ELECTRONIC BALLAST. (2) 3' SECTIONS TANDEM MIRED J6 ON ONE BALLAST. QUICK CONNECT PLUGS. 1 LAMP IN SECTION 8' LINEAR FLUORESCENT IN COVE FIXTURE. ELECTRONIC BALLAST, (2) 4' SECTIONS TANDEM MA RED re ON ONE BALLAST. QUICK CONNECT PLUGS. 1 LAMP IN SECTION 16' BARE LAMP FLUORESCENT STRIP. ELECTRONIC LOW BALLAST FACTOR BALLAST. 1 LAMP IN L8 SECTION, (4) 4' SECTIONS TT CONNECT OH PLUGS BALLAST, QUICK Y t € • CT LU S M6 0 P5 15 TA FT FU DESCRIPTION 8' SURFACE MOUNTED BARE LAMP FLUORESCENT STRIP, ELECTRONIC BALLAST, 1 LAMP IN SECTION, (2) 4' SECTIONS TANDEM MIRED ON ONE BALLAST. QUICK IMRE GUARD CT PLUGS 12' SURFACE MOUNTED BARE LAMP FLUORESCENT STRIP, ELECTRONIC BALLAST. 1 LAMP N SECTION, (3) 4' SECTIONS TANDEM MIRED ON ONE BALLAST. QUICK CONNECT PLUGS MARE GUARD 16' SURFACE MOUNTED BARE LAMP FLUORESCENT STRIP, ELECTRONIC BALLAST, 1 LAMP IN SECTION. (4) 4' SECTIONS TANDEM MIRED ON ONE BALLAST. QUICK CONNECT PLUGS MARE GUARD 4w DIAMETER RECESSED QUARTZ HALOGEN DOMNLIGHT. INTEGRAL ELECTRONIC TRANSFORMER, CLEAR CONE. CHROME TRIM, REMODEL HOUSING • 2) 5' BARE SIDE MOUNT LAMPS T STRIP. 1 LAMP N CTION, (1) 2' STTi1P + (1) 3' TRIP ON EACH SIDE OF MIRROR. TE ELECTRONIC BALLAST 2' LINEAR T5 HO TRUE FISS}l. CONIECH 1RAOC ADAPTOR. RECESSED MONOPOINT PAR30 FRONT LOADING GIMBAL MONOPONT WHITE FVOSI I' X 4' SURFACE MOUNTED LAMS FWORESCENT 1ROFFF D R. ECTRONIC BALLAST I' X 4' SURFACE MOUNTED TWO RC AC DFLUORESCENT LENS. BALLAST 1r DIAMETER : 19" TALL MOUNTED CONICAL CLOTH SHADE. MITE (UNITED) AR30 FRONT LOADING MBA/ TRACK HEAD, NAT1E 1 1W5W AR30 FRONT LOADING GAIL 12 TRACK It MATTE Mi1E 6 GIMBAL RING MRA03C HEAQ T4 ORAL ELECTRONIC TRANSFORMER. MATTE UNIX GIMBAL RING TRACK HEAD. ELECTRONIC 11611 *SW Mal SAL MING *ACK HEAL Mart EI E r-oe' LIEAR 15 MOON OurlAilr IC WWII NM SOW MX MID IMAM Pam wrist mat Moot MEM MOW RIEC7w011C JIM UM= = NNW r-ow wow 2- 1II11P 115 PIM 4111011PMl'7 t1•/LNA• VIM 1 111111011 LIMITED ELECTRICAL LIGHTING SCHEDULE j MANUFACTURER & MODEL NUMBER MERCURY: II I - 134 - OCT fAT C EI>I - 14tf V_ (21WG -101-14Q TALUX: USN - 132 -LRS- 120 -EA81, (2)1MG/SN -4FT U T11ONIk TS -1- 32- 120- (1)L;EB- TAPS', (' DuRAY: EOH1132T2. (21WG -3' E- , , 0 t' MERCURY: M1- 132- OCT /12T- C- E1.11-12Qv, (3)WG- 14I -14Q VETALUX: 12TSN- 132 -LRS -! 20 -EMI, (31MIG/"5N -4FT U THONIA: TS-1- 32 -120- (TIGER- 1111 (+' WURAY: EOH1132TZ -12'. (3111/G- 3' mERCURY: 1111- 132 -OCT /161- C- ELB -120v, (4)WG- W -14Q UE TILL U X: 16 TTNN- t 32 -LRS- 120 -E85L (4)wG/5N -4FT UTHONIA: TS- 1- 32- 120- (1)GEB- T1NP16', 101151: UURAY: EOH1132T2 -16'. (4)WG -3` RSA: IliV2051_ COW RSA: YLV20St_ c1100 PEERLESS: 14Q15 1 39T5H0 U3 120 GE810 I LEDAUTE: 280 -8- HOT - E- N- 03- 1 -1 -E -� 6NS GIT: CF5HO /CMS /3' /1/Ilr MU MA: XE- 11632- 01- 39MIT5 ( AU TE: 280- 8- H01- E- N- 04- 1 -1 -E -V piSIGHT: CF5HO /CVS /4'/1 /Mr cc1 U A: XE -11632 .KME) GE810 L/LP =Au TE: 280 -8- Hal - E- N- 05- 1 -1 -E -� 0N9CHT: CF5H0/CVS/6'/t /1T COLUMBIA: XE- 11632- 01- (2)39WTSHQ PEERLESS: � (2) HMS 1 54T5H0 U4 12Q HALITE: 280- 8- HO1- E- N- Q8- 1 -1 -E -W 1t451GHT: CF5H0 /CVS/B'/1 /I CDLLI181A: XE- 11632 - 01_(2), 54,r MERCURY: 11111- 125- OCT/6T- C- ELB- LW -120v METALUX: 6TSN -125 -ORS- 120- LEOCR1 U T HOI : TS -1 -2S -120 -(I ) QURAIL EOH112ST2 MERCURY: III - 132- OCT/BT -C -at,- LW -12ov METALUX: 8T5N -132- ORS - 120- lEOCSRt UTHOISA: TS -1 -32- 120 -(1)B -TIPS' QURAY: E0111132T2 liglicuRy: W- 132- 0CT/1 C -ELB- LMT -12041 METAL 12TSN- 132 -ORS- 120- L.EOcRi W HOM: TS-1- 32- 120- (1 )GE8- ram 2' QURAY: EOH11321 T2 -12' JRY; W- 132- OCT/16T- C- ELB- LW-I2Ov IETALLJX: 16T5N -132- ORS - 120- LEOC81 UTHONIA: TS -1 -32- 120- (1)GEB- TrP16' QURAY: 10111132n-1W MERCURY: (2)SMC-1-17-(21SMC-1-2S-0CT- (1 w - l2ov USA; (2)5M-1-1742)911-1-25-120- elIERLUX SOLO- 2411110- T5- E- W-T(CONTECH) -120 -MOD REFLECTOR -MOD HOUSING COUE121.18=M cor_hnc en211. MAY: Y 30- 132- OCT- 9A -ELB -12011 INNETALUX: YC- 132! -12 EEC. UTHoNIA: M- 1- 32- Al2- 120-02 MERCURY: M30- 232 - OCCT- 9A- E1B -120Y - 2- 32- Al2 -l20 -n .7.alEXCIBQICasQlruiL HAIt"L L1731P 1lDY_ 1331 -■ !PY_ 133T -• Catelak.SILailmaliampe u U a ►zns nor uz - C1<a11M r aaeneo iltilkaIMELJImw �1F 7ti -� 111MAILALftagiskiEL4EaglI HEIGHT 2 -32 Matt. T8. Med. 3 1 /4. Bi -Pin Bose, Linear Fluorescent. 3000K, 82 CRI. 20.000 Hrs. 3 -32 Watt. T8. Med. 3 1/4' Bi -Pin Bose, Linear Fluorescent. 3000K. 82 CRT. 20.000 Hrs. 4 -32 Watt. T8. Mod. 3 1/41 ` Bi -Pin Bast. Linear Fluorescent. 3000K. 82 CRI. 20,000 Hrs. 35 watt. T5. GY6.35 3 1/2• Bi Pin Bose, Xenon. 35 watts 10.000 Hrs. 20 watt. T4. GY6.35 3 1/2" Bi Pin Bost. Halogen. 20 watts 3000 Hrs. 1.54' 1.54" 1.54" 1.54' 39 Matt. HOTS. Mini, Bi -Pin Bost. Start Linear Fluorescent 3000K. as CRT. 20.000 Hrs. 54 Matt. HOTS. Mini. Bi -Pin Bose, Start Linear fluorescent. 3000K. 85 CRI. 20,000 Hrs. 2 -39 Watt. HOTS. Miniature Bi -Pin Bas• Programmed Start Linear Fluorescwnt, 3000K. a5 cm. now Hrs. 2 -54 Watt. HOTS. Miniature Bi -Pin Programmed Start Linear 3 c. 85 (� 20.000 Hrs. 2 -25 watt. T8. Med. 3 1 /e Bi-Pin Boss. Linear Fluorescent, 300011, 82CR1. 20.000 Hrs. 2 -32 Watt. 111. Med. 3 1 /4' Fl Fluo scent. Linear 82 CRT. 20.000 Hrs. 3-32 Watt. T0. Med. 3 1/4' Bi-Pin Base. Linear �t, 4 -32 Watt. T8. Med. 3 1/4' Eli-Eli-Pin i-' Bose. LM+ear Fluorescent 3000K. 2 -17 Watt. T8. Met • Bose. Linear Fluorescent 3000C. 82 CRT. 20.000 Hrs. 1 11/16' 2- 25watt. TB,. Med. Bi-Pm Bose. Linear Fluorescent. 3000k. 82CM. 20.20.000 His Bi-P Ba Mrs Programmed Start 3000K. 85 ail„ • Fluorescent 20.000 lira. 60 watt, PAR30, Med. Screw Basra, Qnaartz Halogen, Norm, Fl od/Fbod . 3300 acts. 250 3000 Hrs. - 32 Watt, U. Medium 81-Pii Bass. Linear 3 3/4' Fluorescent 82 CRT. 20.000 Heirs, 2-32 Wan. T list K-Pin Bose. Linear 3 3/4" eft, 3000K. 82 CM. 20.000 Hrs. OM MN. 60 epott. PAR301. Mot 'Sava H alown. Narrow . 3300 alto 250D- + 3000 14rs. +r 7S watt or 90wvtt. M10-19. Nit Sores Base. Tempters HalogaA 2000 Hrs. 50 welt. PAR3a MMedirw Screw Bess: I florid 25'. 3000 50 M/t't6. N � 2 Prw 4x S3 3 3/4' Rae. Oi rtz Pedigo'. 30 worts Nerras now 25-- 350o -x000 iNri SO 'IM. WK. 2 Pb GX S.3 Bum Oren= 3 3/4' NNd.ge.i. Newer. SINITARst 11 7-15' (EX1). 3500 Mra 35-37 wen Hit, ISM. 2 PIN CT 5.3 3 3/4. Norm. need 24- 4000 -5000 Ma 24 ot. IB15, •i-Pb Pnesperemell Si..t MOM 85 Cpl 000 Ism LAMP WATTAGE 58 watts 85 watts 112 watts 43 watts 67 watts 85 watts 104 watts 42 watts 51 watts 76 watts 98 watts 42 watts 28 watts 60 watts 32 wits 58 watts 90 watts 60 watts 50 watts SO mats 37 setts aww 38 WWI. PRIM B 2 16W' GM>•o Ossr. mak a we11Ms AI. Ass 3r. NM les *- :� ` AIHIIIta , soft III OIL re. • • • • • • • SYMBOL TS X2 x3 X4 X5 X6 X7 X8 X9 XA DESCRIPTION SURFACE MOUNTED SINGLE F ORCUIT TRACK, MATTE TAMTE SEISM- RECESSED CEILING MOUNTED LED EXIT SIGN. EDGE UT. SINGLE FACE, INJECTION-MOLDED. *EDGE SHAPED ACRYLIC. RED LETTERS, INTEGRAL EMERGENCY SERVICE SEAN - RECESSED CEILING MOUNTED LED EXIT SIGN, EDGE UT. DOUBLE FACE, INJECTION MOLDED, WEDGE SHAPED ACRYLIC, RED LETTERS. DIRECTIONAL ARROWS. INTEGRAL EMERGENCY SERVICE SEMI- RECESSED WALL MOUNTED (BACK) LED EXIT SIGN. EDGE UT. SINGLE FACE, INJECTION-MOLDED. WEDGE SHAPED ACRYLIC. RED LETTERS INTEGRAL EMERGENCY SERVIC SEMI- RECESSED WALL MOUNTED (END) LED EXIT SIGN. EDGE UT. DOUBLE FACE. INJECTION MOLDED. WEDGE SHAPED ACRYLIC. RED LETTERS, DIRECTIONAL ARROWS. INTEGRAL EMERGENCY SERVICE THERMOPLASTIC EXIT SIGN, UNIVERSAL MOUNTING CENUNG/MIALL, LED LAMPS AND INTEGRAL BATTERY BACK UP FOR 90 MINUTES THERMOPLASTIC WALL MOUNTED EMERGENCY LIGHT MATH INTEGRAL BATTERY BACK UP. (2) 5.6W ADJUSTABLE LAMPS HEADS COMBINATION THERMOPLASTIC EXIT SIGN WITH EMERGENCY LAMPS. UNIVERSAL MOUNTING CEBNNG/WALL. LED LAMPS AND INTEGRAL BATTERY BACK UP FOR 90 MINUTES. (2) 5.6W LAMPS FOR EMERGENCY REQUIREMENTS RECESSED EMERGENCY LIGHT FOR SALES FLOOR USE. ADJUSTABLE LAMP, INTEGRAL BATTERY FOR EMERGENCY OPERATION SEMI- RECESSED EMERGENCY UGHT FOR SALES FLOOR USE. (2) ADJUSTABLE LAMPS BELOW CEILING LIE. INTEGRAL BATTERY FOR EMERGENCY OPERATION NOTE: Q ALL FIXTURES ARE FURNISHED BY LSDac TIC. UNLESS oT1ERIMSE NOTED. LIMITED ELECTRICAL LIGHTING SCHEDULE MANUFACTURER 8 MODEL NUMBER DOkt-TECH: LT2P. LT4P. LTWP. LTW. LT12P fag ENO: T211N. T411114. TUN. T811M. T121HI 9s marked 65 P L651 P. L5S2P_ 1 A ssm i c a i ,d ANDY: 2T -W. 4T -IMO 8T -W 8T -W. 12T -W as HIGH -LITES: LED- BPN- RXFO -2 -ac UTHOINIA: LRPWIRC120/277 -EIJ HIGH- LITES: LED -BPN- RXFO -3-RS UDOSALIBriaffilalleaDalizELM HIGH-UTES: LED- BPN- RXF0 -I -RG Ll THOM& LRPWIRC120 /277 -ELN4 i. •_LFD- W'N- XFO- 3- RS -END UTHOISA: Al20/277- ELN -EM ASTRMJTE= TPl1RYEU ASTRALNTE: EU -1 ASTRALIIE: EEL- U- R -W -EV UTNdiA: LHt 1 -SW3R- 120/277 MIGMJ TES: AG -1 UGHTA ARM& 605P1/LH6 F IJ1ES: XC -R -Des qua HEIGHT 11/16• NM MO WO OW MI NM OM MI, OEM 0•16 • 1)03-1.'",..016t 1- - -- - - - . - �. .- T.w,• • • •• IP M 4IrII .VMVWin sYM18o4. oESCaIPnoN MANUFACTURER a MODEL NUMBER HEIGHT LAMP WATTAGE A4 6` DIAMETER RECESSED COMPACT FLUORESCENT DOMNLIGHT. CLEAR CONE. MATTE Frost (=mow BALLAST. SELF FLANGED REFLECTOR UTHONIA- GOTHAM. AFv32TRT6ARLDMVOLT HALO- PORTFOLIO: C7032- 1E- 7C7032-1E-7001-11 a > CV6 -12� /32T- 6000 -SF 10 7/8 B Bost. T GX24q-3 watt, . T riple Compact Fluorescent. 300010. NCR!, 10.000 Hrs. J6 watts • AS 6' DIAMETER RECESSED COMPACT FLUORESCENT DOWNLIGHT, CLEAR CONE, MATTE FINISH. ELECTRONIC BALLAST. SELF FLANGED REFLECTORN UTHONIA- GOTHAM: AFV26TRT6AR,pMVOLj HALO- PORTFOUQ; C7032- 1E- 7001 -H LK;HT R -CAL LIE 8022Ct:AP_ 71 2eu , CV6- 126 /321- 60QC -SF 9 5/8" 26 watt. T4, 4Pin GX24q -3 Boss, Triple Compact Fluorescent. 3000K. NCR!. 10,000 Hrs. 32 watts A7 8' DIAMETER RECESSED COMPACT FLUORESCENT D0IMNLIGHT. CLEAR CONE, MATTE mast ELECTRONIC BALLAST. SELF FLANGED REFLECTOR UTHONIA- GOTHAM: AFV42TRT8ARLDVVOLT HALO - PORTFOLIO: C7Q42 -1E- 7401 -H LIG11101.1ELTLALCAMELIKOMDE, ,ENO: CV8- 126/32/42T- 8200 -SF 11 3/8' 42 watt. T4. 4Pin GX -4 Bose. Triple Compact Fluorescent. 3000K, 82CRI. 10.000 Hrs. 46 watts A9 7' DIAMETER RECESSED HALOGEN .A. LAW DOV IUGHT, CLEAR co*:, MA FINISH. SELF FLANGED REFLECTOR TH V ONIA - GOTHAM: A7AF�Q HALO- PORTFOuO: HD7- 7701 -9 10 51 75 wolf or 90watt MB -19, Medium Screw Bost. Tungsten Halogen. 2000 Hrs. 90 watts UL'INTOLIER- CALCJJLITE: C7OSSCCDP. C70Q - 6430 -SF AE 6` DIAMETER RECESSED HORIZONTAL LAMP COMPACT FLUORESCENT pOMNLIGHT. CLEAR CONE. MATTE FINNISH. ELECTRONIC BALLAST, SELF FLANGED REFLECTOR UTHONIA- GOTHAM: AF1 /32Tj6ARLDYVOLT HALO-PORTFOu0. 06132 -1E- 6051 -11 UfaingarSALCULLELIMIZILALVEU 7 I/4" 32 watt. T4. 4Pin GX24q -3 Bose, Triple Compact Fluorescent. 3000K, 82CR1. 10,000 Mrs. 36 watts • AF 6` DIAMETER RECESSED HORIZONTAL LAMP COMPACT LUOMANLIGHT. L C MATTE RESCENT FINI ELECTRONIC CEAR BALLAST. SELF p REFLECTOR THONIA- GOTHAY: AF 1 /26TR 6AR LD MVOLT 7 11'" 26 watt. T4. 4Pin GX24q -3 Bost, Triple Compact Fluorescent. 8 . 1 ao Hrs. 32 watts HA M- O- PORTF01.10: 06132 -IE- -H _ AG 6' DIAMETER RECESSED HALOGEN 'A' LAMP DOMNUGHT. CLEAR CONE, MATTE mist SELF FLANGED REFLECTOR UTHONIA- GOTHAM: AZjANLQ HALO- PORTFOLIO: H7601T- 1641H CA! cue TE' E705,,90Ct1P. E610 ,NJNO: TC906H- 673C -5F _ 7 3/4' 75 watt or 90watt, 119 Tungsten Sc Halogen, 2000 . 90 watts • Ell 3 7/8` DIAMETER RECESSED ADJUSTABLE ACCENT LIGHT. CLEAR REFLECTOR. NTEGRAL. ELECTRONIC BALLAST P -ITE: YH4A- TA4C -120V 4 3 / +. . AR20. ��i Oeor. M 3000K. 85 CRT. Flood 30'. 9000 Hrs. 46 watts BP 3' DIAMETER RECESSED ADJUSTABLE MR16 Do1MlLIGHT, CLEAR CONE. MATTE VIHITE TRIM. INTEGRAL ELECTRONIC TRANSFORMER - 5 1 / 50 Watt Halog MR16. 2 Pin X5.3 Base Quartz Halogen. Narrow Flood 25'30 3500- 6000 Hrs. watts • BR 3" DIAMETER RECESSED ADJUSTABLE MR16 DOMANLIGHT, CLEAR CONE. MATTE TIHITE TRIM, INTEGRAL ELECTRONIC TRANSFORMER RSA: YLV305S 0500, M6 5 1 /2' 35-37 watt HIR, MR16. 2 Pin GX 5.3 Bose. Quartz Halogen. Narrow Flood 24 -25; 4000 -5000 Hrs. 37 watts 85 4` DIAMETER RECESSED ADJUSTABLE MR16 ACCENT UGHT, CONICAL DROP HINGE LAMP. MATTE BLACK FIaStt. 358" ROTATION. 85' AD.*USTABILITY, INTEGRAL TRANSFORMER RS-'A'• mi 6_ snap/EL/166 S 1/2' 50 Watt Halogen. MR16. 2 Pin GX s�3 uartztz Halogen. 50 watts Narrow Flood 25*-30' 900• -6000 Hrs. • 4" DIAMETER RECESSED ADJUSTABLE MR16 ACCENT UGHT. CONICAL DROP HINGE BT MATTE BL LAW. MAACK Fi1NISH, 358' ROTATION. 85' ADJUSTABIUTY, NTEGRAL ELECTRONIC TRANSFORMER S 1 36 6, 2 Pin GX watt HMI. Bose. Quartz Halogen, 3 Flood 24 4000 -5000 Hrs, 37 watt _ 8 DIAMETER RECESSED COMPACT FLUORESCENT DOMNUGHT WAL.LWASHER, CLEAR C7 BALLAST. mot. LECTRONIC REFLECTOR HALO- PORTFOLIO: C7042-1E-7411-11 UO ITOLIER- CALCuuTE: _ 714 21111 A LTGOSiiA1C wFVw 11421RT DAR - A NO: Cv8- 126 /32/421- 8200- yoWS -Sr 11 1S/16` 42 watt,. T4, 4Pin pl24q -4 Bast, Triple 1 ee t, Hrs. 46 wolf: 2' BARE LAMP FLUORESCENT F2 STRIP. ELECTRONIC BALLAST. 1 LAMB' N SECTION MERCURY: 11M- 117- OCT- C- ELB -12()V tTALUX: SN- 117- LRS -12Q -E881 UTHONIA: S-1 -17 -120 -08 3 1/4" 3 1 4• / 17 Watt. T5,, Medium Bi Bost Lin. Fluorescent. 3000K. 82 CRS, 20,000 Itrs. Meirrn 25watt. T$ Fnr EN Bose. Linear Fluorescent 300x , 82CRI. 20.000 Hrs. 20 ;.rite 27 watts QURAY: ETH1117 3' BARE LALASAP MP T F3 STRIP, ' BA ELECTRONIC BALLAST. t LAMP N SECTION Y: W- 125- OCT- C- ELB -120v - 125 -O-120E 1 4 RS UTHONIA: 5- 1- 25- 120-x@ QURAY: EOH1125 41 4' BARE LAMP T F4 STRIP, ELECTRONIC BALLAST. 1 LAMP N SECTION MERCURY: It,/- 132- OCT- C- ELB -120v 3 1/4" 32 Matt. T0. M.tfirnt EN-Pin -Pin Base. Linear Fluorescent. 30001(. 82 CRT. 20.000 Hrs. 32 watts InTALUX: SN -132- ORS- 124-EBS1 UTHONIA: s -1 -32- 120-0 QURAY E01112 F 3' CHAIN HUNG BARE LAMP FLUORESCENT STRIP ELECTRONIC BALLAST. 1 LAMP N SECTION MIRE GUARD YERCIECJIIIr12 5- OCT- C- EL9 - 120V_ MG-JIM-13M O4AIN /3FT .`.. 3 1/". 3 1 /4' t'gp T8, Medium Ln ear exert. 3000k. BZCW. 20.000 Nirs. 3,Z Maatt. TB�, Medium Linear Wi 82 CRI. 20.000 Hrs. 27 watts 32 watts METALUX: 5N- 125 -ORS- 120 - EMI, 1. WG/5N -3FL EYE CHAIN SET/ 3FT UTHONIA: 5- 1- 25- 120 -CEa BGS3r CJ4AN/'j QURAY: EO11112S. VIG -3" -Y T. CHAIN /3FT 4' (HMI HUNG BARE LAMP +FK FLUORESCENT S11tP ELECTRONIC BALLAST, 1 LAMP N SECTION MIRE GUARD W- 132- 0CT- C-- E1B -120v, W-1� CHINLRS- �jAt.ux 9r- 132 -Efts- 120 -FBSt. j s Y •es! -4FL ElE F]�IAN uzza umiak : - 1- 32- t20-Cf L Get• DURAY: E0H1132 V -3'_ C1�1AN f, CatilhaEl 6' CHAIN HUNG BARE LAMP FLUONESCDIT STRIP. ELECTRC IC BALLAST. 1 LAID N SNEC110NN, FL (2) 3' SECTIONS TANDEM MIRED ION ONE BALLAST. QUICK CONNECT PLUS'' MIRE GUARD 1 Y`- 111- 125- 0CTi%T- C- EL8 -120M, (2 -W -130 CMAN/3FT 2- 2swott ' Met Ft 47 .its , Hrs. METAN.UX S1 4- 125 -ORS- 120 -E�1, - 3 1/4' 111 A: TS--1- 225 - 120- (i)GEB- TiP16', QURAY: EOH112S17_ (21•G -r -7T CF1AIi1✓.Y T • aiA1N HuN G BARE LAMP I . s: • T S1RP. ELJEC1T , 1 L N SECTION. . FM 2) 4' SECTIONS TAI EMM MIRED ' ONE BALLAST. QUICK CT PLUGS M1I1E GUARD 2-32 Best, B. M ,or�esosrrt. 3000K. watts _ JJC NUALI S ie. 132 - O RS - 120 -EBSt_ (2/1»/ i -4FT_ EYE Gum SETI T 3 1 / 1 LISA: -1 -37- �T1tP� CA. 210.000 we • 12' CHAIN HUNG BARE LAW • -. is • 3 STRIP. ELECTRONIC . 1 LAMP ei swim. FM 3) 4' SECTIONS TANDEM WIRED • ONE BALLAST, OUICK • • CT PLODS GUARD 1E1 TRY- � L12 fi (311G-W -ice DlA JVT Lofts 3-32 butt, 10. Meri. (3 )uCiS EYE oval SNETLv T 3 1/4' UMIHIONIk 15r1 -32- 121- (1)1E- W L ' 02 ail. 240100 Itrst. 16' CHAIN HUNG saw LAMP • . • 3 T SHIP, ELECTRaec . 1 LAMP M Wok ' FD 4) 4� SECTIONS TANDEM M1JiED • QE BALLAST. moot • • CT PLUGS GUANO IERCtBtY- MMH 132 a [T/16T -L ( ic "NIIt -ism C'MAMlET 4--32 Watt. 1E Mie6. 'sm. Dom fit. (. 82 GM. 20.0 les. 112 salts TM . 1614N- 132 -kE 3 1 /4 Lick Ts- -1 -32 ilia i1r011I- ' -1NC (4)iis..3" 0.1818/23 12r AME LAMP COMPACT FP • ■- • 3 Slap, atcipop . I LAtip NN SEC10N KlEirchisibidiElle,ArliEngE �i� � Nom- k�� 3 3/r" 1a welt. T4, 4Ph 2011 sm. comonwat FlrerwN■�e lest. MOIL AIM 12.000 Hera. T 2D alts 911W'ACE 110u TED WANK IFq 3 1 _1 1 UMW IN OIMIAI KUILI o_ 9W -Ells- so-_ •� •�•r 3 1/4" _ �. _ 1/1-41b 34 WA L 24.040 oft 27 salts - 0 T swam WOUNIED WM IncillEke Ste 3 11*5* ' MUM 1 L � M u1lINJimmt S -1 -3?- 1110 -CM. f4 iE E awe 1"1. Ees 6 lOsOwws Law 32 m ins IQ a. NUM lMnr. 901110E MM181NMED 1111011EICIBIIT sMr1K 3 ; B PS • z ' , =ED A at most. • • o T RIM r 111111111111 C Ir11It - 1u1 1�r•l!!~11l�Ar� t- ts- tl+• Al1>w•11RrW 3 1r +. �Z3s.AL 1• ma 10-1 Oa Wow 47 sells L =NO ws • H 8 K CONSULTANTS. LTD 171 CHARRING CROSS DR S SUITE 18 WESTERVILLE. OHIO 43081 (814)882 -1199 �.ww..w•tlt' +w7+w.f f;+nlN.(li...:y:a fti t REVISIONS: maim w OVATE MIA MINI it CHECKED IT: 0 t- cD G 10/16/03 RLK EDT REK LIMITED • • • • SYMBOL FW HI 4` DIAMETER RECESSED QUARTZ HALOGEN DOV OUGHT INTEGRAL • H3 ELECTRONIC TRANSFORMER, CLEAR CONE. CHROME REMODEL HOUSING 6' BARE LAMP FLUORESCENT • L5 STRIP. ELECTRONIC LOW BALLAST FACTOR BALLAST, 1 LAIN' IN SECTION a' BARE LAMP FLUORESCENT STRIP. ELECTRONIC LOW BALLAST FACTOR BALLAST. 1 LAMP IN • L6 SECTION. (2) 4' SECTIONS TANDEM MIRED ON ONE BALLAST, QUICK CONNECT PLUGS 12' BARE LAMP FLLIORESCDO STRIP. ELECTRONIC LOW BALLAST FACTOR BALLAST. 1 LAMP N • L7 SECTION. (3) 4' SECTIONS TANDEM MIRED ON ONE BALLAST, QUICK CONNECT PLUGS • W 3' LINEAR FLUORESCENT IN J3 FIXURE„ ELECTRONIC BALI AST, T LAMP IN SECTION 4' LINEAR FLUORESCENT IN COVE J4 FIXTURE. ELECTRONIC BALLAST. 1 LAMP IN SECTION 6' LINEAR FLUORESCENT M COVE FIXTURE. ELECTRONIC BALLAST. (2) 3' SECTIONS TANDEM MIRED J6 ON ONE BALLAST. QUICK CONNECT PLUGS. 1 LAMP IN SECTION 8' LINEAR FLUORESCENT IN COVE FIXTURE. ELECTRONIC BALLAST, (2) 4' SECTIONS TANDEM MA RED re ON ONE BALLAST. QUICK CONNECT PLUGS. 1 LAMP IN SECTION 16' BARE LAMP FLUORESCENT STRIP. ELECTRONIC LOW BALLAST FACTOR BALLAST. 1 LAMP IN L8 SECTION, (4) 4' SECTIONS TT CONNECT OH PLUGS BALLAST, QUICK Y t € • CT LU S M6 0 P5 15 TA FT FU DESCRIPTION 8' SURFACE MOUNTED BARE LAMP FLUORESCENT STRIP, ELECTRONIC BALLAST, 1 LAMP IN SECTION, (2) 4' SECTIONS TANDEM MIRED ON ONE BALLAST. QUICK IMRE GUARD CT PLUGS 12' SURFACE MOUNTED BARE LAMP FLUORESCENT STRIP, ELECTRONIC BALLAST. 1 LAMP N SECTION, (3) 4' SECTIONS TANDEM MIRED ON ONE BALLAST. QUICK CONNECT PLUGS MARE GUARD 16' SURFACE MOUNTED BARE LAMP FLUORESCENT STRIP, ELECTRONIC BALLAST, 1 LAMP IN SECTION. (4) 4' SECTIONS TANDEM MIRED ON ONE BALLAST. QUICK CONNECT PLUGS MARE GUARD 4w DIAMETER RECESSED QUARTZ HALOGEN DOMNLIGHT. INTEGRAL ELECTRONIC TRANSFORMER, CLEAR CONE. CHROME TRIM, REMODEL HOUSING • 2) 5' BARE SIDE MOUNT LAMPS T STRIP. 1 LAMP N CTION, (1) 2' STTi1P + (1) 3' TRIP ON EACH SIDE OF MIRROR. TE ELECTRONIC BALLAST 2' LINEAR T5 HO TRUE FISS}l. CONIECH 1RAOC ADAPTOR. RECESSED MONOPOINT PAR30 FRONT LOADING GIMBAL MONOPONT WHITE FVOSI I' X 4' SURFACE MOUNTED LAMS FWORESCENT 1ROFFF D R. ECTRONIC BALLAST I' X 4' SURFACE MOUNTED TWO RC AC DFLUORESCENT LENS. BALLAST 1r DIAMETER : 19" TALL MOUNTED CONICAL CLOTH SHADE. MITE (UNITED) AR30 FRONT LOADING MBA/ TRACK HEAD, NAT1E 1 1W5W AR30 FRONT LOADING GAIL 12 TRACK It MATTE Mi1E 6 GIMBAL RING MRA03C HEAQ T4 ORAL ELECTRONIC TRANSFORMER. MATTE UNIX GIMBAL RING TRACK HEAD. ELECTRONIC 11611 *SW Mal SAL MING *ACK HEAL Mart EI E r-oe' LIEAR 15 MOON OurlAilr IC WWII NM SOW MX MID IMAM Pam wrist mat Moot MEM MOW RIEC7w011C JIM UM= = NNW r-ow wow 2- 1II11P 115 PIM 4111011PMl'7 t1•/LNA• VIM 1 111111011 LIMITED ELECTRICAL LIGHTING SCHEDULE j MANUFACTURER & MODEL NUMBER MERCURY: II I - 134 - OCT fAT C EI>I - 14tf V_ (21WG -101-14Q TALUX: USN - 132 -LRS- 120 -EA81, (2)1MG/SN -4FT U T11ONIk TS -1- 32- 120- (1)L;EB- TAPS', (' DuRAY: EOH1132T2. (21WG -3' E- , , 0 t' MERCURY: M1- 132- OCT /12T- C- E1.11-12Qv, (3)WG- 14I -14Q VETALUX: 12TSN- 132 -LRS -! 20 -EMI, (31MIG/"5N -4FT U THONIA: TS-1- 32 -120- (TIGER- 1111 (+' WURAY: EOH1132TZ -12'. (3111/G- 3' mERCURY: 1111- 132 -OCT /161- C- ELB -120v, (4)WG- W -14Q UE TILL U X: 16 TTNN- t 32 -LRS- 120 -E85L (4)wG/5N -4FT UTHONIA: TS- 1- 32- 120- (1)GEB- T1NP16', 101151: UURAY: EOH1132T2 -16'. (4)WG -3` RSA: IliV2051_ COW RSA: YLV20St_ c1100 PEERLESS: 14Q15 1 39T5H0 U3 120 GE810 I LEDAUTE: 280 -8- HOT - E- N- 03- 1 -1 -E -� 6NS GIT: CF5HO /CMS /3' /1/Ilr MU MA: XE- 11632- 01- 39MIT5 ( AU TE: 280- 8- H01- E- N- 04- 1 -1 -E -V piSIGHT: CF5HO /CVS /4'/1 /Mr cc1 U A: XE -11632 .KME) GE810 L/LP =Au TE: 280 -8- Hal - E- N- 05- 1 -1 -E -� 0N9CHT: CF5H0/CVS/6'/t /1T COLUMBIA: XE- 11632- 01- (2)39WTSHQ PEERLESS: � (2) HMS 1 54T5H0 U4 12Q HALITE: 280- 8- HO1- E- N- Q8- 1 -1 -E -W 1t451GHT: CF5H0 /CVS/B'/1 /I CDLLI181A: XE- 11632 - 01_(2), 54,r MERCURY: 11111- 125- OCT/6T- C- ELB- LW -120v METALUX: 6TSN -125 -ORS- 120- LEOCR1 U T HOI : TS -1 -2S -120 -(I ) QURAIL EOH112ST2 MERCURY: III - 132- OCT/BT -C -at,- LW -12ov METALUX: 8T5N -132- ORS - 120- lEOCSRt UTHOISA: TS -1 -32- 120 -(1)B -TIPS' QURAY: E0111132T2 liglicuRy: W- 132- 0CT/1 C -ELB- LMT -12041 METAL 12TSN- 132 -ORS- 120- L.EOcRi W HOM: TS-1- 32- 120- (1 )GE8- ram 2' QURAY: EOH11321 T2 -12' JRY; W- 132- OCT/16T- C- ELB- LW-I2Ov IETALLJX: 16T5N -132- ORS - 120- LEOC81 UTHONIA: TS -1 -32- 120- (1)GEB- TrP16' QURAY: 10111132n-1W MERCURY: (2)SMC-1-17-(21SMC-1-2S-0CT- (1 w - l2ov USA; (2)5M-1-1742)911-1-25-120- elIERLUX SOLO- 2411110- T5- E- W-T(CONTECH) -120 -MOD REFLECTOR -MOD HOUSING COUE121.18=M cor_hnc en211. MAY: Y 30- 132- OCT- 9A -ELB -12011 INNETALUX: YC- 132! -12 EEC. UTHoNIA: M- 1- 32- Al2- 120-02 MERCURY: M30- 232 - OCCT- 9A- E1B -120Y - 2- 32- Al2 -l20 -n .7.alEXCIBQICasQlruiL HAIt"L L1731P 1lDY_ 1331 -■ !PY_ 133T -• Catelak.SILailmaliampe u U a ►zns nor uz - C1<a11M r aaeneo iltilkaIMELJImw �1F 7ti -� 111MAILALftagiskiEL4EaglI HEIGHT 2 -32 Matt. T8. Med. 3 1 /4. Bi -Pin Bose, Linear Fluorescent. 3000K, 82 CRI. 20.000 Hrs. 3 -32 Watt. T8. Med. 3 1/4' Bi -Pin Bose, Linear Fluorescent. 3000K. 82 CRT. 20.000 Hrs. 4 -32 Watt. T8. Mod. 3 1/41 ` Bi -Pin Bast. Linear Fluorescent. 3000K. 82 CRI. 20,000 Hrs. 35 watt. T5. GY6.35 3 1/2• Bi Pin Bose, Xenon. 35 watts 10.000 Hrs. 20 watt. T4. GY6.35 3 1/2" Bi Pin Bost. Halogen. 20 watts 3000 Hrs. 1.54' 1.54" 1.54" 1.54' 39 Matt. HOTS. Mini, Bi -Pin Bost. Start Linear Fluorescent 3000K. as CRT. 20.000 Hrs. 54 Matt. HOTS. Mini. Bi -Pin Bose, Start Linear fluorescent. 3000K. 85 CRI. 20,000 Hrs. 2 -39 Watt. HOTS. Miniature Bi -Pin Bas• Programmed Start Linear Fluorescwnt, 3000K. a5 cm. now Hrs. 2 -54 Watt. HOTS. Miniature Bi -Pin Programmed Start Linear 3 c. 85 (� 20.000 Hrs. 2 -25 watt. T8. Med. 3 1 /e Bi-Pin Boss. Linear Fluorescent, 300011, 82CR1. 20.000 Hrs. 2 -32 Watt. 111. Med. 3 1 /4' Fl Fluo scent. Linear 82 CRT. 20.000 Hrs. 3-32 Watt. T0. Med. 3 1/4' Bi-Pin Base. Linear �t, 4 -32 Watt. T8. Med. 3 1/4' Eli-Eli-Pin i-' Bose. LM+ear Fluorescent 3000K. 2 -17 Watt. T8. Met • Bose. Linear Fluorescent 3000C. 82 CRT. 20.000 Hrs. 1 11/16' 2- 25watt. TB,. Med. Bi-Pm Bose. Linear Fluorescent. 3000k. 82CM. 20.20.000 His Bi-P Ba Mrs Programmed Start 3000K. 85 ail„ • Fluorescent 20.000 lira. 60 watt, PAR30, Med. Screw Basra, Qnaartz Halogen, Norm, Fl od/Fbod . 3300 acts. 250 3000 Hrs. - 32 Watt, U. Medium 81-Pii Bass. Linear 3 3/4' Fluorescent 82 CRT. 20.000 Heirs, 2-32 Wan. T list K-Pin Bose. Linear 3 3/4" eft, 3000K. 82 CM. 20.000 Hrs. OM MN. 60 epott. PAR301. Mot 'Sava H alown. Narrow . 3300 alto 250D- + 3000 14rs. +r 7S watt or 90wvtt. M10-19. Nit Sores Base. Tempters HalogaA 2000 Hrs. 50 welt. PAR3a MMedirw Screw Bess: I florid 25'. 3000 50 M/t't6. N � 2 Prw 4x S3 3 3/4' Rae. Oi rtz Pedigo'. 30 worts Nerras now 25-- 350o -x000 iNri SO 'IM. WK. 2 Pb GX S.3 Bum Oren= 3 3/4' NNd.ge.i. Newer. SINITARst 11 7-15' (EX1). 3500 Mra 35-37 wen Hit, ISM. 2 PIN CT 5.3 3 3/4. Norm. need 24- 4000 -5000 Ma 24 ot. IB15, •i-Pb Pnesperemell Si..t MOM 85 Cpl 000 Ism LAMP WATTAGE 58 watts 85 watts 112 watts 43 watts 67 watts 85 watts 104 watts 42 watts 51 watts 76 watts 98 watts 42 watts 28 watts 60 watts 32 wits 58 watts 90 watts 60 watts 50 watts SO mats 37 setts aww 38 WWI. PRIM B 2 16W' GM>•o Ossr. mak a we11Ms AI. Ass 3r. NM les *- :� ` AIHIIIta , soft III OIL re. • • • • • • • SYMBOL TS X2 x3 X4 X5 X6 X7 X8 X9 XA DESCRIPTION SURFACE MOUNTED SINGLE F ORCUIT TRACK, MATTE TAMTE SEISM- RECESSED CEILING MOUNTED LED EXIT SIGN. EDGE UT. SINGLE FACE, INJECTION-MOLDED. *EDGE SHAPED ACRYLIC. RED LETTERS, INTEGRAL EMERGENCY SERVICE SEAN - RECESSED CEILING MOUNTED LED EXIT SIGN, EDGE UT. DOUBLE FACE, INJECTION MOLDED, WEDGE SHAPED ACRYLIC, RED LETTERS. DIRECTIONAL ARROWS. INTEGRAL EMERGENCY SERVICE SEMI- RECESSED WALL MOUNTED (BACK) LED EXIT SIGN. EDGE UT. SINGLE FACE, INJECTION-MOLDED. WEDGE SHAPED ACRYLIC. RED LETTERS INTEGRAL EMERGENCY SERVIC SEMI- RECESSED WALL MOUNTED (END) LED EXIT SIGN. EDGE UT. DOUBLE FACE. INJECTION MOLDED. WEDGE SHAPED ACRYLIC. RED LETTERS, DIRECTIONAL ARROWS. INTEGRAL EMERGENCY SERVICE THERMOPLASTIC EXIT SIGN, UNIVERSAL MOUNTING CENUNG/MIALL, LED LAMPS AND INTEGRAL BATTERY BACK UP FOR 90 MINUTES THERMOPLASTIC WALL MOUNTED EMERGENCY LIGHT MATH INTEGRAL BATTERY BACK UP. (2) 5.6W ADJUSTABLE LAMPS HEADS COMBINATION THERMOPLASTIC EXIT SIGN WITH EMERGENCY LAMPS. UNIVERSAL MOUNTING CEBNNG/WALL. LED LAMPS AND INTEGRAL BATTERY BACK UP FOR 90 MINUTES. (2) 5.6W LAMPS FOR EMERGENCY REQUIREMENTS RECESSED EMERGENCY LIGHT FOR SALES FLOOR USE. ADJUSTABLE LAMP, INTEGRAL BATTERY FOR EMERGENCY OPERATION SEMI- RECESSED EMERGENCY UGHT FOR SALES FLOOR USE. (2) ADJUSTABLE LAMPS BELOW CEILING LIE. INTEGRAL BATTERY FOR EMERGENCY OPERATION NOTE: Q ALL FIXTURES ARE FURNISHED BY LSDac TIC. UNLESS oT1ERIMSE NOTED. LIMITED ELECTRICAL LIGHTING SCHEDULE MANUFACTURER 8 MODEL NUMBER DOkt-TECH: LT2P. LT4P. LTWP. LTW. LT12P fag ENO: T211N. T411114. TUN. T811M. T121HI 9s marked 65 P L651 P. L5S2P_ 1 A ssm i c a i ,d ANDY: 2T -W. 4T -IMO 8T -W 8T -W. 12T -W as HIGH -LITES: LED- BPN- RXFO -2 -ac UTHOINIA: LRPWIRC120/277 -EIJ HIGH- LITES: LED -BPN- RXFO -3-RS UDOSALIBriaffilalleaDalizELM HIGH-UTES: LED- BPN- RXF0 -I -RG Ll THOM& LRPWIRC120 /277 -ELN4 i. •_LFD- W'N- XFO- 3- RS -END UTHOISA: Al20/277- ELN -EM ASTRMJTE= TPl1RYEU ASTRALNTE: EU -1 ASTRALIIE: EEL- U- R -W -EV UTNdiA: LHt 1 -SW3R- 120/277 MIGMJ TES: AG -1 UGHTA ARM& 605P1/LH6 F IJ1ES: XC -R -Des qua HEIGHT 11/16• NM MO WO OW MI NM OM MI, OEM 0•16 • 1)03-1.'",..016t 1- • • i CONDUIT 1" CONDUIT W/ PULL MARE O TELEPHONE /COMPUTER SYSTEM SCHEMATIC • ♦ ( V KI V T T T C CM /1 STUB AT DEMISING WALL / .- ----1' CONDUIT MI/ PULL IMRE • LIMITED MANAGER NOTE: 1. ADDITIONAL PHONE OUTLETS MAY BE REQUIRED. SEE FLOOR PLAN FOR LOCATION. 1" CONDUIT W/ PULL MARE 36" A.F.F. 2. SEE /WRAP DETAILS ON SHEET E04.2 FOR NOTES AND FLOOR PLANS FORA NOTES. N.T.S. L MUDS DIMON OF MA ME urIN 1Q Or IYCIN;a COMM. en DUPLEX 111ECEPTACIE INFADIERP1100F COOL Ms" NM Com111112ED roma moor NOM COOSMMTE Viva IATNOI or _ S iiM W1AN mil 20 OS MOW 10 KM NMI Poem STANCHION MOUNTIES) LIGHT mum( MN GLOBE. WARD AND Malt A-21 imp 3 s' INGO E vNw12Ep comour we � INRE POLE 100111LE 911TOn 11r/ 111.A1INEOP1100 F CON= MON 10 ACM 1>r/ COMM C UMP ACCU LK,IlT/RECEPTACLE RTS I J LHALVJa SOUND SYSTEM CODED NOTES 0 COAXIAL SPEAKER ENCLOSURE (#CP87) AND SUPPORTS FURNISHED AND INSTALLED BY "DMX`. 0 SPEAKER MARE FURNISHED AND INSTALLED BY "DUX. 'WEST PENN' /25224 /18 AMID OR "DECARON" 1P70 /18 ANC M. NO SUBSTITUTIONS. ELECTRICAL CONTRACTOR TO RUN PULLSTRING Mr COUNDUIT. F REQUIRED BY LOCAL CODE. SEE ELECTRICAL SPECIFICATIONS FOR EXACT REQUIREMENTS) BETWEEN SPEAKER ENCLOSURES AND TO SYSTEM CABINET LOCATED NN NON- SALES. SOUND SYSTEM CABINET FURNISHED BY "DMX" AND MOUNTED BY ELECTRICAL CONTRACTOR. SEE "SOUND SYSTEM INSTALLATION DETAIL" ON THIS SHEET FOR MOUNTING SPACE REQUIREMENTS AND ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 0 E.C. TO RUN (2) PAIR OF /18 AWG WEAKER MARE IN 3/4" CONDUIT FOR EACH TELEPHONE SYSTEM AS REQUIRED. LABEL AND TAG MARE AT EACH END THUS: `M.O.H," AND "TELECO PAGE ". i LEAVE 6' -0" OF COILED. TAPED & LABELED SPEAKER HARING (TYP, EACH CIRCUIT) NON —SALES SOUND SYSTEM INSTALLATION DETAIL 0 0 14" WALL SPACE ON HINGED SDE OF SOUND SYSTEM CABINET. 6'- .1. REI 0 1. DMX'S CONTRACTOR SHALL INSTALL SPEAKER ENCLOSURES. SUPPORTS AND SOUND SYSTEM CABINET AS FURNISHED BY 'OMX". 2. SPEAKERS. SPEAKER GRILLES. AMPLIFIER. SOURCE PLANER INSTALLATION. PREMARE AND FINAL CONNECTIONS ARE BY 'DUX', 3. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT QUANTITY AND LOCATION OF SPEAKERS, ELECTRICAL CONTRACTOR SHALL NOTE ANY CONFLICTS IN FIELD AND NOTIFY PROJECT MANAGER OF SAME, CIRCUIT CHANGE MUST BE APPROVED BY ENGINEER OR "Due". fig: SPEAKERS THAT MUST BE MOVED. DUE TO FIELD CONDITIONS. MUST MAINTAIN A SYMMETRICAL PATTERN. 4. F YOU HAVE ANY QUESTIONS REGARDING MUSIC SYSTEM INSTALLATION CALL LIMITED PROTECT MANAGER WITH "MAX" AT 1- 800 -831 -8001. 5. SPEAKER LAYOUT IS SCHEMATIC. USE "DUX" FINAL APPROVED PLANS FOR PLACEMENT AND WRING OF SPEAKERS. 6. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL A 4" x 4" GANG BOX AT CENTER POINT OF ALL WEAKER LOCATIONS WNIIEN HARING MUST BE RUN IN CONDUIT. (2) 1 -1/2" EMT CONDUIT FOR WEAKER WIRE. RUN INSIDE WALL. TERMINATE IN OPENING. K4 BOX INSIDE LEAVE 6' -0" OF COILED. TAPED & LABELED WEAKER TARING (TIP. EACH DOUBLE DUPLEX RECEPTACLE, SEE SHEET (01.1. MOUNT CENTERLINE OF RECEPTACLE AT 7' -0' A.F.F. LIMLIED SOUND SYSTEM GENERAL NOTES SALES c)044P N.T.S. FLUSH W/ WALL f SECTION "A" NT$ BATTERY BOX BEHIND WALL TENANT ELEC. CENTR SWILL CONFIRM WAIL OPENING SIZE W/ FIXTURE FURNISHED PRIOR TO ROUGH TENANT ELEC. CONTR SHALL COiI�MBA CELNG 11P'EMNHG SIZE 1r/ FIXTURE FURNISHED PRIOR 10 ROUGH -111 BOX ABOVE CEILING. ACCESS THRU SIGN COMM WI MENG EXIT LIGHT DETAIL F M011011 SENSOR SN1Ol IN Am aA ( FER TO 9#ET E031 Loam CODED NOTE Li) -\\ C l uGMING Lwei M ilina f SIEMAT FOR 2 ROOM EXHAUST FAN N.TS. REAR DOOR , REAR DOOR PW1 9 UTT • PUSHBUTTON w • • 3' 1 1 Oil / 120 VAC 24 VAC SALES BELL/BU NON -SALES BU 3. PARALLEL MORE BELL/BUZZERS. NOTES: 1. ROUTE CONDUIT UP MILL OR MU NN TO CEILING SPACE. 2. RUN 11RE IN CONDUIT IF REQUIRED BY CODE. OTHERWISE USE PLENUM RATED 1II> C DELIVERY BUZZER AND SCHEMATIC N.T.S. C B TRACK ATTACHMENT DETAR. KT.a 1 A H B K CONSULTANTS. LTD 171 CHARRING CROSS DR S SUITE 1 B WESTERVILLE, OHIO 43081 (6142 -1 11,1 :41111.1 11.1 co 0 0 r O W Or n. I i A :';', ." l'; j %. JJ, J l ry' 1 �y 11 �- 1 , Ci w 5 7.: „N so ,. � Zi o I � � J 0 �t co . 0 • MOM .. SW' DATE IME1k DESIGNED I ORMIN CNIEOCED BY: EXPIRE 1111111111411111111111111111 ‘ molhommoiumaoo Cor) O z 0 • � G .'A M Z D t` CC ui 0 s :: z o u —1 ° • Q. Z '-' O 7.0 W C9 ea o° O ? CO Q W � cc ! d J f- 1 1 ININNING R: E04.1 I- - Z W O e [ 1e La rt W""*. 0 < W p O N z 1171 0 N. Z 0 ;;;It 0 0 0 If-- U O J H W U tail NL -31 E. Z a. U OvN0 ta VI O REVISIONS: It+ol.INls R 10/1 6/03 INK EDT RDK ELECTRICAL DETAILS S • • • NO OF ANTENNAS SLAB ON GRADE SLAB ABOVE GRADE LENGTH OF EXCAVATION 7' —C 2.18m (7'21 2 13' -4" 12' —B" 4.34m (14'3 ") 3 19' -8" 18' -4" 6.51m (21'41 4 26' -0" 24' -0" 8.67m (28'51 MIME pp18 _ ∎■ tea_ -■ OB NTS VATION BACKWRAP I 0 ® .tl Jiff' ZYMier @ PLAN NEW B +� •NTS NO METAL REBAR OR WIRE MESH WITHIN 21cm (8 ") OF BOTTOM AND 31cm (121 OF SIDES OF ANTENNA NOTE: REFER TO ARCHITECT SHEETS FOR ADDITIONAL INFORMATION AVIV CONDUIT STOP —UPS CONNECT TO CIRCUIT SHOWN ON POWER PLAN 4 REG CASH /WRAP COUNTER DETAIL ELEVATION POWER PACK DATA TERMINALS AND CONNECTIONS BY P.O.S. CONTRACTOR CONNECT TO CIRCUIT SHOWN ON POWER PLAN ❑ REMOTE ALARM ANTENNAS (3cm (1.25 ") IAN TO 5cm (2 ") MAX BELOW SURFACE OF CONCRETE FLOOR). — CONDUIT RUN R 10.5m 35') O 16.Sm 55' MAX C:'.P BOARD ENCLOSURE REMOTE ALARM — 2Dcm (8 ") MIN — 7 .5 ( MAX c — 7.5M f,25) MAX — RS -2 PLATE 32 SENSORMATIC DIGITAL FLOORMAX SYSTEM DETAIL CASH /WRAP & TELE /COMP SYSTEM NOTES (=DI REGISTERS SHALL SHARE A 20 AMP, 120 VOLT DEDICATED CIRCUIT VATH A SEPARATE ISOLATED NEUTRAL & 3RD WIRE GROUND. STUB UP 3/4' CONDUIT. INSTALL FLEXIBLE CONDUIT FROM STUB —UP TO J —BOX AND CONNECT TO DUPLEX RECEPTACLES. THE ELECTRICAL CONTRACTOR SHALL FURNISH ORANGE /1G5262 RECEPTACLES (HUBBELL) CUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT TO WALL AS SHOWN. ROUTE UP INSIDE WALL TO CEILING SPACE AND CONNECT TO PANEL LOCATED INSIDE WR ENCLOSURE. REFER TO POWER PLAN AND PANEL SCHEDULES FOR CIRCUIT DESIGNATIONS. O 20 AMP, 120V., CIRCUIT FOR UTILITY POWER W/DUPLEX RECEPTACLE. STUB UP 3/4' CONDUIT. INSTALL FLEXIBLE CONDUIT FROM STUB —UP TO J —BOX AND CONNECT TO DUPLEX RECEPTACLES. CUT AND PATCH FLOOR AS REQUIRED TO ROUTE UP INSIDE WALL TO CEILING SPACE AND BACK TO PANEL AS INDICTED ON POWER PLAN. cp STUB UP 3/4" CONDUIT. INSTALL FLEXIBLE CONDUIT FROM STUB —UP TO 4X4 J —BOX FOR DATA CUT KE PATCH FLOOR AS REWIRED TO ROUTE CONDUIT TO WALL AS SHOWN. ROUTE UP IN WALL TO CEILING SPACE AND CONNECT TO TELECO STRUCTURE PORTION OF THE IFS SWITCHGEAR. WIRE FOR DATA LINES TO BE PULLED AND CONNECTED BY P.O.S. CONTRACTOR. ® 20 AMP, 1200., CIRCUIT FOR UTILITY POWER W/DUPLEX RECEPTACLE BY ELECTRICAL CONTRACTOR. CONNECT TO CIRCUIT AS SHOWN ON POWER PLAN. Q TELEPHONE OUTLET ON INSIDE OF BACK WRAP UNIT. SEE "CASH /WRAP" NOTE(6). TELEPHONE WIRE AND IRJ45S JACK FOR POLLING AND CREDIT BY OTHERS © 3/4" TELEPHONE CONDUIT WITH PULLWIRE TO TELEPHONE BOARD BY ELECTRICAL CONTRACTOR. /RA4C JACK ON LINES /1 AND /2 FOR TELEPHONE BY OTHERS. Q EDWARDS I15 —OAJ BUZZER BY ELECTRICAL CONTRACTOR. SEE "POWER NOTES" ON POWER PLAN FOR ADDITIONAL INFORMATION. © 20 AMP, 1200., CIRCUIT FOR ES SAONAL C TENOON P. TERMINA CIR CUIT IN JUNCTION BOX FOR FUTURE EXTENSION BY OTHERS. TE MATE; RUN ROMEX WIRING TO EACH RECEPTACLE FROM J —BOXES THRU WAREWAY WITHIN CASHWRAP COUNTER. NUDE; WIRING FROM CONDUIT STUBS —UPS TO J —BOXES ARE TO BE RUN IN FLEXIBLE CONDUIT. MOTE: LABEL AND TAG AU. PULLWIRE RUNS AT EACH END PATH ORIGIN/DESIGNATION. CASHWRAP COUNTER DETAIL THE LIMITED 4 REGISTER CASHWRAP SENSORMATIC DIGITAL FLOORMAX SYSTEM CD DUPLEX RECEPTACLE BOX LOCATED IN AREA ABOVE CEILING. ELECTRICAL REQUIREMENTS ARE 120V. AC, THREE WIRE, ISOLATED GROUND, 24 HOUR CIRCUIT WITH LESS THAN 0.5V. AC BETWEEN NEUTRAL AND GROUND. N.T.S. RETURN AIR GRILLE OR ACCESS PANEL TO BE USED FOR SERVICING OF EQUIPMENT LOCATED ABOVE CEILING. COORDINATE ROUGH —IN OF JUNCTION BOX AND RECEPTACLE WITH THE GENERAL CONTRACTOR. SD (NOT USED) © 1 -1/2 INCHES DEEP x 4 FOOT WADE (APPROXIMATE) SAWCUT FOR EACH FLOOR PANEL. DEPTH OF CUT SHALL BE LEVEL THROUGHOUT. CONFIRM ACTUAL DIMENSIONS OF SAWCUTS RATH MANUFACTURER'S INSTRUCTIONS. IF THE SLAB CANNOT BE CUT FOR THE INSTALLATION OF THE FLOOR (ANTENNA) PANELS, THE GENERAL CONTRACTOR MUST INVESTIGATE THE OPTION OF "FLOATING" THE PANELS IN AN ADDITIONAL LAYER OF POURED CONCRETE ('RAMPING UP'). THIS WALL DEPEND ON THE LEVEL OF THE FLOOR INSIDE THE STORE IN RELATION TO THE LEVEL OF THE FLOOR IN THE MALL. THE TYPE OF FINISHED FLOORING WALL HAVE SOME EFFECT ON THE ACTUAL DEPTH OF THE FLOOR PANELS IN THE SLAB. THE THICKNESS OF THE FLOORING PLUS THE THICKNESS OF THE CONCRETE PATCH OVER THE PANELS SHOULD BE APPROXIMATELY 1 -1/2 INCHES. CD SAWCUT FLOOR 1' WOE x 1 -1/2" DEEP FOR INSTALLATION OF 3/4" CONDUIT. ® NOTCH TRENCHES AT CONNECTOR LOCATIONS OF FLOOR PANELS. TYPICAL OF ALL FLOOR PANELS. O JUNCTION BOX WITH 120V. AC POWER FOR FINAL CONNECTION TO SENSORMATIC POWER PACKS. INSTALLATION OF POWER PACKS AND PLUG —IN OF PACKS TO RECEPTACLE BY SENSORMATIC. IF YOU HAVE ANY QUESTIONS PLEASE CALL SENSORMATIC (BRUCE SECOR) AT 1 -561- 939 -3040. MDSE;. CONTRACTOR MUST VERIFY AN UNOBSTRUCTED MINIMUM FREE AREA OF 3 FEET VERTICALLY AND 3 FEET WIDE IN EVERY DIRECTION ABOVE THE ACCESS PANEL TO ALLOW FOR INSTALLATION OF THE SENSORMATIC POWER PACK AND CAP ENCLOSURE BOXES. IF FREE AREA CANNOT BE OBTAINED IN THIS LOCATION, IMMEDIATELY CONTACT THE LSD &C PROJECT MANAGER FOR FURTHER INSTALLATION INSTRUCTIONS. St^p P °P �ITgN RfQUIRF� .. J N.T.S. CD INDIVIDUAL 3/4 INCH RIGID GALVANIZED STEEL(CRITICAL) CONDUIT INTERCONNECTS BETWEEN EACH FLOOR PANEL AND ITS RESPECTIVE CAP ENCLOSURE BOX — CAP ENCLOSURE BOXES ARE LOCATED ABOVE CEILING WITHIN 2 FEET OF POWER PACK. ONE POWER PACK WILL HANDLE A MAXIMUM OF__ _ 4 FLOOR PANELS AND 4 CAP BOXES. CONDUIT ABOVE CEILING SHALL BE ROUTED CLEAR OF ACCESS OPENING. MAXIMUM LENGTH OF CONDUIT SHALL NOT EXCEED 35' FROM FLOOR PANEL TO CAP BOX. PVC CONDUIT WILL NOT BE ALLOWED. 0 CAP BOARD ENCLOSURE (FURNISHED BY "SENSORMATIC" AND INSTALLED BY GENERAL CONTRACTOR PER THE RESPONSIBILITY SCHEDULE). EACH CAP BOX MUST BE MOUNTED WITHIN 2 FEET OF POWER PACK. 171 CHARRING CROSS DR S SUITE 18 WESTERVILLE, OHIO 43081 (614)882 -1199 Co ' Co W 0 0 r 0 ♦c C W I A ZZO�f J U u.I I- 0Lj L =N I— Cl) N REVISIONS: MUM BY: DRAWING NUMBER: E04.2 DATE DATE ISSUED: 1 0/1 6/03 DESIGNED BY: RLK DRAWN BY: EDT CHECKED BY: REK ELECTRICAL DETAILS EQUIPMENT WIRING SCHEDULE SYM. ITEM VOLTAGE HP. KW. F.L.A. FEEDERS TYPE OF CONN. BRANCH BREAKER DISC. SW. BUSS FUSES REMARKS WIRE COND. 0 WATER HEATER 120v, 10 -- 1.5 -- 2/12 GTHHN 1/I2 RD 3/4• 'AC' TOGGLE SWITCH 20A -1P 1.315 3.600• SEE NOTE N0. 1 BELOW 0 HP -1 & 2 208V, 3o -- 17.709 -- 3K THOU 1 GRD 1 1/4' DIRECT 60A - 3P HACK 60/3 NFDS 12.359 10.313 0 AHU -1 & 2 208V, 30 1.5 -- -- IN TMON 3/4° DIRECT 15A -3P NFDS - -- 26.612 O4 RF -1 2080, 30 2 -- -- 3;; 2 TERN 3/4 DIRECT 20A -3P N 30 5 17.602 1.0 0 VAV - 1 2080 30, 3W 1/2 5.0 -- 3/10 THH 1/10 GR 3/4° DIRECT 30A -3P - -- ___ C. RAL NS MEA DIS INTEG TO UNIT 0 ROLLING GRILLE 1200. 10 1/2 -- -- 2/12 GRD TNH 1 3/4° TOGH GLE 'AC• TC SWI 20A -1P - -- - -- SEE NOTE NO. 1 BELOW 7 O EBBH -7, 2 & 3 120V, 10 -- 0.75 -- 2/12 THHN 1 GRD 3/4 DIRECT 20A -1P - -- ___ DISC. RA ME INTEGL ANS TO UNIT D 8 DREAM STEAMER 200V . 30 -- 9.0 -- 3/10 THHN 1 GRD 3/4• SECIAL QUTLE 30A -3P - -- - -- NEMA L1S -308 RECE PTACLE NO TFS' 1. AC• TOGGLE SWITCH TO BE FURNISHED BY LSD&C AND INSTALLED BY ELECTRICAL CONTRACTOR ELECTRIC LOAD SUMMARY SYSTEM 208V Zod Oescipt'an ne Loa CASH REGISTER ACTUAL POWER ACTUAL N.E.C. N.E.C. N.E.C. DESCRIPTION CONNECTED KW/KVA FACTOR DEMAND KVA CONNECTED KW/KVA DEMAND FACTOR DEMAND KVA LIGHTING 18.016 • 22.520 22.316 1.25 27.895 SHOW WINDOW LIGHTING ALLOWANCE 1 052 • 1.315 3.600• 7.25 4.500 RECEPTACLES 11.780 1.0 10.890 11.780 1.0 < 1 0.5 REYMNING KW 10.890 MOYORS 10.313 0.9 12.359 10.313 .2511 LARGEST 12.359 FIXED ELECTRIC SPACE HEATING - -- 10 - - -• - • TO - - -• AIR CONDITIONING SYSTEM 26.012 1.0 26.612 26.012• 1.0 5; +25% LARGEST 26.012• ELECTRIC WATER HEATER 1.500 1.0 1 :i00 1.500 1.0 1.500 MISCELLANEOUS 17.602 1.0 17.602 17.602 1.0 17.602 TOTAL 86.275 - -- - -- 92.198 93.123 24 26 100.758 NO1E5 0 0 - -- ___ - -- ___ B C - -- ___ • USE GREATER VALUE OF THE TWO CATEGORIES •• N.E.C. ARTICLE 220 -12 REQUIREMENT (2000A PER FOOT OF SHOW WINDOW) MINUS ACTUAL INSTALLED SHOW WINDOW LIGHTING VA. ••• 125% OF THE LARGEST MOTOR OF COMPRESSOR IN SYSTEM. APPLIED ONLY ON ONE UNIT. • POWER FACTOR IS ALREADY INCLUDED IN UGHTING LOAD. N.F C OFMAND KVA 0101 MINIMUM FEEDER AMPERAGE SYSTEM VOLTAGE x 3 3.000 x lnnn 1n208 Y79.68 AMPS REUSE EXISTING 600 AMP SERVICE z 1 n758 73 at. No. I Zod Oescipt'an ne Loa CASH REGISTER Sin Bra 91• e Opts LO N.E.C. KW 1.000 Aclud KN 1.000 "o. A Actual KW 0.360 NEC KW 0.360 B. � Opts Sae • LO • Load Descriplkn TELEPHONE BD Ckt. Zaire No. 2 3 JTILITY POWER SEASONAL C/W LO LO 0.720 0.400 0.720 0.400 8 C 0.500 0.360 0.500 0.360 LO LO TEMP. CTR. PAL. MGR. COMPUTER 4 6 9 FF BACKWRAP REC. EBBH -3 LO LO 0.720 0.750 0.720 0.750 A B 0.360 0.360 0.360 0.360 LO LO 'SOUND SYS. ia�EENSORMATIC 8 10 11 SALES REC. SALES REC. 0.540 0.540 0.540 0.540 C A 1.500 0.700 1.500 0.700 LO REFRIGERATOR `MICROWAVE 12 I4 ABR ABR SALES REC. SALES REC. C C 0.540 0.720 0.540 0.720 B C 1.500 7.500 1.500 1.500 LO LO WATER HEATER EBBH -1 & 2 16 18 21 NON -SALES REC NON -SALES REC TRAGHTS TRAGHTS 0.720 0.540 0.720 0.540 A B 1.127 0.560 1.127 0.560 LO LO ROLLING GRILLE ACCU LT./REC. 20 22 23 25 VON -SALES REC. SPARE BABR 0.640 - -- 0.640 - -- C A - -- - -- - -- - -- SPARE SPARE 24 26 27 29 SPARE SPARE 0 0 - -- ___ - -- ___ B C - -- ___ - -- __- SPARE SPARE 28 30 31 DREAM STEAMER t {30/3 LO 3.000 3.000 B SPORE SPARE 32 34 37 SPACE 11 __ 3.000 ___ 3.000 ___ C ___ ___ __ SPARE SPACE 36 38 39 41 SPACE SPACE -- -- - -- - -- - -- - -- CO C., - -- - -- - -- - -- -- -- SPACE SPACE 40 42 al. No. Zone Lore Dewipl'nn Brkr Sae BM1r . Opts NEC KW AGAR KW PNiii Actud KW 0.600 NEC KW 0.9009ABR Br. B. Opts Laotl Description TRACK LIGHTS Zane C Z No. 2 1 3 A SIGN A ENTRY LIGHTS 3ABR BABR 1.200 0.096 1.200 0.096 A B 1.050 0.IoII 1.650 0.0 ABR ABR TRACK LIGHTS TRACK LIGHTS C C 4 6 A STORE FRT. LTS A SNOW WIN. TRACK BABR BABR 0.184 7.200 0.184 0.332 C A 1. 0 0 ABR ABR TRAGHTS TRAGHTS C C 0 0 ABR ABR TRAGHTS TRAGHTS C C 0 0 ABR BABR TRAGHTS TRAGHTS C C 0 - BABR TRAGHTS pPA22 C B -1T. 0 0 AGHTS TRAGHTS C C GHTS C 35 SPARE - -- - -- C 1.160 0.380 1.160 BABR BABR •TG. RM. MILTS DOWNLIGHTS C C 34 36 37 39 SPACE SPACE - -- - -- - -- - -- - -- - -- A B - -- - -- - -- - -- -- -SPACE -° -SPACE 38 40 41 SPACE ___ ___ ___ Q ___ ___ ___SPACE 42 p POWER RISER DIAGRAM GENERAL NOTES 7 HVAC CIRCUIT BREAKERS SHALL BE "HAM" TYPE WHERE REWIRED BY EQUIPMENT NAMEPLATE PER N.E.C. 2 ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT K.A.I.C. RATING OF LANDLORDS DISTRIBUTION EQUIPMENT, FURNISH AND INSTALL LIMITED SYSTEM TO MATCH. 3 ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO 7% (0) BETWEEN PHASES: A/B, B /C, A/C REGARDLESS OF CIRCUITING INDICATED. 4 PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. 5 ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FORA COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. NOTES: 1. ALL PANEL BRANCH CIRCUIT BREAKER SHALL BE BOLT -ON TYPE. 2. ALL PANEL BUS BARS SHALL BE COPPER. 3. MOUNT A TYPEWRITTEN DIRECTORY BEHIND GLASS OR PLASTIC ON THE INSIDE OF EACH PANEL DOOR AND, ON THE DIRECTORY, SHOW THE CIRCUIT NUMBER AND COMPLETE DESCRIPTION OF ALL OUTLETS ON EACH CIRCUIT. NOTE: ELECTRICAL CONTRACTOR SHALL VERIFY AMPERE INTERRUPTING CURRENT CAPACITY IF READING IS FOUND TO BE HIGHER THAN PANEL RATING, NOTIFY YOUR LSO &C PROJECT MANAGER IMMEDIATELY. (BUILDING SERVICE AVAILABLE FAULT CURRENT) PRIOR TO INSTALUNG SWITCHGEAR. IFS ENCLOSURE FURNISHED BY LSD &C AND INSTALLED BY ELECTRICAL CONTRACTOR AS HEREIN DESCRIBED: A. UNIT WILL BE SHIPPED TO PROJECT IN MULTIPLE SECTIONS AND THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR OFF- LOADING GT EQUIPMENT, INSPECTION OF EQUIPMENT FOR DAMAGES, VERIFICATION OF EQUIPMENT RECEIVED IS FOR PROPER STORE, SETTING AND MOVING OF EQUIPMENT INTO SPACE AS WELL AS REASSEMBLING OF SECTIONS INTO ONE COMPLETE UNIT PER MANUFACTURERS DOCUMENTATION. B. ELECTRICAL CONTRACTOR IS TO CONNECT ALL PROVIDED INTERCONNECTING CABLES BETWEEN SECTIONS AND TORQUE CONNECTIONS PER MANUFACTURER'S REQUIREMENTS C. ALL CONNECTIONS WITHIN THE TELEPHONE/DATA SECTION AND HVAC CONTROL SECTION OF THE IFS ENCLOSURE WILL BE DONE BY OTHERS. ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR INSTALLATION OF LOW VOLTAGE CONDUIT SYSTEM INTO THESE SECTIONS ONLY. D. SWITCHBOARD WILL BE SHIPPED ON A ENCLOSED SEMI-TRAIL ELECTRICAL CONTRACTOR MUST ARRANGE FOR A FORKUF7 TO UNLOAD AT JOB SITE. ELECTRICAL CONTRACTOR WILL RECEIVE 24 HOUR NOTICE PRIOR TO DEUVERY. IFS ENCLOSURE LIGHTING CONTROLS SOLENOID OPERATED BABR BREAKERS ARE PROVIDED WITHIN IFS PANELS FOR STORE LIGHTING CONTROLS AND STOREFRONT SIGNS. SEE PANEL SCHEDULES FOR LIGHTING ZONE DESGNATIONS (.E.: ZONE A, 8 OR C). EXISTING TWO (2) PARALLEL SETS OF 44350 MCM THW AND 1/1 GRD. IN AN EXISTING 3 CONDUIT PER SET TO REMAIN. EXISTING METER, METERING C /T'S, METERING C/T CABINET TO REMAIN. VERIFY EXACT REQUIREMENTS IN FIFI O PRIOR TO 910: L 1 J Panel Wiring Schedule (3-Phase) Pandb.:ad A Volloge 120/208 PhoseL WKe 4 IOC Rating 65000 Panel Type PRI lA Mans 5 a P M O Mains Rating 775 AMP NEMA Type Enclosure 1 Mounting SURFACE Options Note Notes 0H '8 Oo nn eRU WII breakers to be 20 -Am erw's p, 1 -Pole udess Othe noted. Sde a d Operated BURR Breaker R lck LO - mde lo-off device Actual Load TotdseA 6.268kw N.E.0 Connected ToldsO 91361. ST - REnl Trip Type 06 6.3B21n 0B 71A7R 0118 - Aud�uy Cans •C 6.418ke BE 79181. PA -WHAM PaATA. tal Allodmall - TOId 19.C6Rkw TOId 242361n GFO - Ground Font W R Interrupter HACK Heati A/C & Rettig...1 (All Phases to be bdon. to wiUn 7S usig Actud Load Tolds.) NOTE: THIS PANEL IS NOT INCLUDED IN THE ELECTRICAL BID AS THIS WILL BE INCORPORATED IN THE IFS, INTEGRATED FACILITY SYSTEM PANEL THAT WILL WE SUPPUEO BY LSD&C. REFER TO SINGLE LINE DIAGRAM BELOW FOR MORE INFORMATION. ELECTRICAL PANELS AND RISER DIAGRAM LANDLORD r - -� - - --I EXISTING 600A -3P FUSED SERVICE RATED DISCONNECT SWITCH WITH EXISTING LPN -RK 600 I J I I I EXISTING TWO (2) PARALLEL SETS OF 4/350 MCM TRW AND 1/1 GRD. IN AN EXISTING 3° CONWIT PER SET TO REMAIN. ICOND ' EXISTING TWO (2) PARALLEL 1 4/350 UIT O THOU AND 1/1 GRD. IN AN SETS EXISTING 3 PER SET 70 REMAIN. EXISTING LANDLORD SERVICE PICK -UP POINT. VERIFY EXACT LOCATION AND REQUIREMENTS IN FIFI n PRIM TO Fon. W-CP VERIFY EXACT DISTANCE IN FIELD. LEASE UNE LIMITED SPACE NEW TAP BOX FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. ,MAIN I HP -1 60 A HACR 00 OO RF -1 20 A I1 ZI a legend: A - Mvketing B - Slockbg C - Soles PANEL FEEDER FURN. BY IFS MFGR. AS RE TIRED. E.C. TO MAKE FINAL CONNECTIONS TO PANELBOARD (TYP.) -� POWER RISER DIAGRAM NT8 600 A PANEL A PANEL B 125 A 125 A r� l\ AHU -1 AHU -2 15 A 15 A HP -2 60 A HACR O® VAV -1 30 A r1 Cam' ® 0o-H-o 0® O® Panel WWitlp Schedule (3- Phase) Pandboard 8 Voltage 120/208 PhaseL OAR 4 AC Rating 65.000 Pond Type PRI IA Mains 2255 AMP MLO Mains Roting 775 AMP NEMA Type Enclosure t Mounting SURFACE Options Note Notes Breaks OolionH .Ad ciait breakers to be 20 -Amp, 1 -Pole Doles otherwise rated. OMR - Solenoid Operated BABR Weaker LO - Hawk lock -oll deriee Acton! Load TotdseA 85275. NEC. Connected ToldKak 8.577kw ST - Shunt Trip Two 08 8.4704 eB A 470kw AUX - Audi. Cantata 0C A 660kw 0C R 6601. PA O - - GSM Fad/ Honde PaOak Allo Told 25.6570. Told 25.6575. GF Gait nlerruDler HACK - Ht91ng, A/C &Refrigeration (A0 Phases to be bdonce0 to within 71T usng Actual Lood Tolls) NOTE: THIS PANEL IS NOT INCLUDED IN THE ELECTRICAL BID AS THIS WILL BE INCORPORATED IN THE IFS, INTEGRATED FACILITY SYSTEM PANEL THAT WILL BE SUPPLIED BY LSD &G REFER TO SINGLE LINE DIAGRAM BELOW FOR MORE INFORMATION. TWO (2) PARALLEL SETS OF 7.........„. 4/350 MCM THOU AND 1/1 GRD. IN A 3 CONDUIT PER SET FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 19 2 2 26 2e 30 32 42 LIGHTING CONTROLS AND TELEPHONE /HVAC EQUIPMENT CONTROL PANEL E.C. SHALL FURNISH AND INSTALL A 3/4° CONDUIT AND PULLWIRE FROM DEMARK TO IFS ENCLOSURE. -� DEMARK PROVIDED BY PHONE CO. ROOF CEILING C.C. TO PROVIDE AND INSTALL 12 %12 %3/4" PLYWOOD SURFACE MOUNTED BACKBOARD ON WALL. LOCATE ON RIGHT SIDE CF ELECTRIC EQUIPMENT. Ogee LeaenA A - Marketing B - Sled. C - Sales FLOOR APpR A Np H B K CONSULTANTS, LTD 171 CHARRING CROSS DR S SUITE 16 WESTERVILLE, OHIO 43081 (614)882 -1199 co CO 0 0 0 ONON0$ ^ 6110 /O� REVISIONS: sroaem er: r � ^ ?ECEVEa CCT 2 2 2X3 ✓e++Mi�t.Eei DRAWING NUMBER: E05.1 CATE DATE ISSUED: 10/16/03 DESIGNED BY: RLK DRAWN BY: EDT CHECKED BY: REK ELECTRICAL PANELS AND RISER DIAGRAM DIVISION 15 - MECHANICAL SECTION 15000 BASIC MECHANICAL REQUIREMENTS A. NOTE 1• THE ABBREVIATION LSD &C WHEREVER IT APPEARS IN THESE MECHANICAL DRAWINGS AND /OR SPECIFICATIONS SHALL REFER TO LIMITED STORE DESIGN AND CONSTRUCTION. ANY REFERENCE TO TENANT'S PROJECT MANAGER OR FURNISHED BY ANY OF THE ABOVE REFERS TO LSD &C. 2. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIO NSA AND TH ER SPECIFICATION SECTIONS, APPLY TO THIS ND THE ALL OT SECTIONS OF DIVISION 15. 3. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF THIS SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TO PROVIDE THIS SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 4. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THIS WORK TO COMPLY WITH THE LSD &C SCHEDULE AND THE PROJECT COMPLETION DATE. 5. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF HIS WORK. REFER TO RESPONSIBILITY SCHEDULE ON SHEET E00.0 DRAWINGS FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. 6. B. GENERAL REQUIREMENTS 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR LSD &C SHALL BE PROVIDED BY THIS CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND THE LSD &C CONSTRUCTION MANAGER, AS REQUIRED. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF CONTRACT. 4. ALL WORK IN THIS SECTION SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD CONSTRUCTION PRACTICES. 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS. PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. 7. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING AND CHANNELING REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY LSD &C PROJECT MANAGER AND THE LANDLORD. ALL PATCHING SHALL BE BY G.C. AND SHALL MATCH THE SURROUNDING SURFACES. 8. THE PLUMBING CONTRACTOR SHALL MAKE ALL FINAL PLUBING CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. C. (PARAGRAPH OMITTED) M CODES 1. ALL WORK SHALL CONFORM TO THE LANDLORDS' CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED C A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS AWARDED, CHANGE ORDERS FOR INCREASED COSTS DUE TO CODE ISSUES WILL NOT BE ACCEPTED BY LSD &C. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. LICENSES, PERMITS, INSPECTIONS & FEES THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS WORK. FURNISH TO THE LSD &C'S PROJECT MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY LSD &C'S PROJECT MANAGER THROUGH THE SHOP DRAWING SUBMITTAL PROCESS, PRIOR TO INSTALLATION. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS ;TIME PROJECT MANAGER FOR APPROVAL SUBMISS SHALL BE MADE EARLY ENOUGH iN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR LSD &C PROJECT MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL CONTRACTOR AND THE SUB - CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. G. GUARANTEE 1. THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER HIS CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT HIS OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL OR DUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION B ASD &C'S PROJECT M EXQUI WARRANTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. 2. THE EQUIPMENT MANUFACTURER SHALL GUARANTEE AND PROVIDE A 12 MONTH GUARANTEE TO LSD &C FROM THE DATE OF ACCEPTANCE. THE CONTRACTOR SHALL WARRANT THE INSTALLATION OF THIS EQUIPMENT AND WILL BE RESPONSIBLE FOR ANY GE DAMA AND /OR MALFUNCTION CAU BY THE INSTALLATION. THIS .ONTRA RKI SHALL NOT BEAR ADDITIO NAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM. H. RECORD DRAWINGS I. THIS CONTRACTOR SHALL MAINTAIN ONE SET OF DRAWINGS ON THE DR AWING S, UPSUCDATED H A5: WEEKLY TO RECORD ALL DEVIATIONS FROM CONTRACT A. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. B. REVISIONS. ADDENDUMS, AND CHANGE ORDERS. C. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL THIS CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. FAILURE TO KEEP THESE RECORDS WILL ALLOW LSD &C TO DIRECT THE GENERAL CONTRACTOR TO PROVIDE THESE RECORDS AT HIS EXPENSE PRIOR TO FINAL PAYMENT. PLUMBING SPECIFICATIONS I. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, D DETAILS) RE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AN AND INTENT A OF THE PLUMBING SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE T ADVISE LSD PROJECT MANAGER, WRITING, VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION ON OF BID. . OTHERWISE, LSD PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. J. PHASING REQUIREMENTS 1. THIS CONTRACTOR IS TO INCLUDE IN HIS BID ALL NECESSARY SERVICE REQUIRED TO KEEP THE OPERATING PHASE OF THE STORE'S HVAC, PLUMBING AND SPRINKLER SERVICE IN OPERATION. CONTRACTOR MUST SCHEDULE IN WRITING WITH LSD &C'S PROJE1 MANAG ER AND THE LANDLORD ONE WEEK PRIOR TO ANY SHUT DOWN OF THE HVAC. PLUMBING OR FIRE PROTECTION SYSTEMS. K. DEMOLITION 1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. 2. THIS CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING FIRE PROTECTION, PLUMBING FIXTURES AND PIPING NOT TO BE REUSED ON THIS PROJECT. UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, ETC. PRIOR TO REMOVAL. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND F /FLOORR PATCHED/ DUC TO UI PME TXINT FLOOR, EXISTING ABANDONED PIPES, DUCTS, R EQUIPMENT SI THE FLOOR, EMBEDDED IN CONCRETE OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW R HIPROJECT. IF REQUIRED BY LANDLORD OR R TO BE ED C DES, ABANDONED N THIS PIPING AND /OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL L SLEEVES 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SIUCATE, SILICONE "REV" FOAM. "3M" ARE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE N0. 22 U.S.G. GALVANIZED STEEL MINIMUM. M. HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C-CUMPS WITH RETAINING CUPS, CHANS RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORKNEL , HANGER . 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER S EQUIPMENT. HANGER RD C TES ERIA. AND INSTALLATION METHODS ARE ALSO UBJECT TO NDLYPRIT 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6" LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELECTRICALLY SEPARATED. N. FINAL PLUMBING INSPECTIONS 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, LSD &C SHALL HAVE AN INDEPENDENT PLUMBING CONTRACTOR INSPECT THE FINISHED PLUMBING INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT PLUMBING CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS. END OF SECTION 15000 A. SCOPE OF WORK 1. C. FIXTURES AND EQUIPMENT AS SCHEDULED. D. COMPLETE NATURAL GAS OR PROPANE PIPING SYSTEMS (AS APPLICABLE, REFER TO PLANS). E. CONANS). DENSATE PIPING SYSTEMS (AS APPLICABLE, REFER TO PL F. TESTS AND ADJUSTMENTS. G. KEEPING RECORD SET AND DO AS- BUILTS. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE PLUMBING SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 8. EQUIPMENT AND INSTALLATION THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL T0, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL WORK FOR THE PLUMBING SYSTEMS B SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: A. COENTS. MPLETE SANITARY PIPING SYSTEMS OF WASTE, DRAINS, AND COMPLETE ND HOT WATER PIPING SYSTEMS, APPURTENANCES COLD A AND INSULATION. RELOCATION OF EXISTING WATER, GAS, WASTE, VENT, OR DRAINAGE LINES TO ROP FACILIT ATE STORE DESIGN CRITERIA MUST RE INCLUDED IN BID P REFER TO PLANS FOR SCHEDULES OF EQUIPMENT AND FIXTURES. AMERICAN STANDARD, KOHLER AND CRANE ARE CONSIDERED ACCEPTABLE AS EQU 2. SANITARY PIPING A. WASTE, DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON SOIL PIPE. VENT PIPING ABOVE FLOOR 2" OR B. C. SECTION 15200 PLUMBING SMALLER MAY BE GALVANIZED STEEL ALTERNATE PIPING MATERIALS ARE ACCEPTABLE AS A SUBSTITUTION WHEN THEIR USE IS PERMITTED BY THE LANDLORD, LOCAL DOES A ND BUILDING DEPARTMENT OFFICIALS AND DOES NOT AF OTHER TRADES. SUBSTITUTIONS MUST BE LISTED AND QUALIFIED IN BID. INSULATE ALL HORIZONTAL RUNS OF PIPING LOCATED IN CEILING SPACES OF TENANTS IN SPACES BELOW, W HEN APPLICABLE. INSULATION TO BE AS SPECIFIED FOR WATER PIPING. CONDENSATE PIPING SHALL BE TYPE 'L' DRAWN COPPER TUBE WITH 95 -5 TIN - ANTIMONY SOLDERED JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS. 3. POTABLE WATER PIPING SHALL BE B FOLLOWS: A. BELOW GRADE: TYPE 'K', ANNEALED TYPE TEMPERED COPPER TUBE FOR PIPE SIZES 2 INCHES AND SMALLER. BRAZE ALL JOINTS. B. ALL OTHER: TYPE 'L" DRAWN COPPER TUBE WITH WROUGHT COPPER FITTINGS AND 95 -5 TIN - ANTIMONY SOLDER. 4. 5. 6. 7. 8. 2. 7. 8. PIPING OF DISSIMILAR METALS MUST BE DI- ELECTRICALLY SEPARATED. GENERALLY, SANITARY AND POTABLE WATER TAPS WILL BE VID BY THE LANDLORD_ FIELD VERIFY EXACT CONNECTION POINTS PRO PRIO R TO SUBMITTING ID AND NOTIFY LSD &C "S PROJECT MANAGER, IF CONDITIONS ARE NOT AS SHOWN THE PLANS OR STATED IN THE SPECIFICATIONS. CONTRACTOR MUST VERIFY THE OPERER ABILITY OF ENTIRE SYSTEM PRIOR TO TIE IN AS FOLLOWS: A. SNAKE SANITARY TO MALL MAIN AND REPORT ANY BLOCKAGE. B. TEST WATER PRESSURE TO INSURE MINIMUM PSI MATCHES MOST DEMANDING EQUIPMENT SUPPLIED. INSULATE ALL HOT WATER, COLD WER AND O CNDENSATE PIPING WITH 1 THICK ( ME O LOCAL FAT ) PIPE INSULATION WITH PR ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREE AND SMOKE DEVELOPED RATINGS. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES DE UNR LAVATORY WITH 1/2" ARMSTRONG °ARMAFLEX" PIPING INSULATION OR TRUEBRO MODEL 102W `HANDI LAY GUARD° INSULATION KIT. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SU ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE DE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. 9. STERILIZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. 10. CLEAN -OUTS AND FLOOR DRAINS SHALL BE INSTALLED PER LOCAL CODES. WALL COVERS ARE TO BE STAINLESS STEEL AND FLOOR COVERS ARE TO BE BRASS, UNLESS OTHERWISE SPECIFIED. PROVIDE FLOOR COVERS WITH INSEREA FOR CARPETED LOCATIO ALL PROJEC LOCATIONS SHALL T A BE A PPROVED BY LSD &C'S PROJECT MANAGER. 11. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE PENETRATIONS AT WALLS, FLOORS, AND CEILINGS IN FINISHED AREAS. 12. LEAKAGE TESTS SHALL BE PER LOCAL CODES, MINIMUM AS FOLLOWS: A. TEST WATER PIPING AT 100 PSIG FOR SIX HOURS. 8. TEST DRAIN, WASTE, VENT PIPING BY A 10' WATER COLUMN FOR TWO HOURS. 13. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA. USE A LANDLORD APPROVED ROOFING CONTRACTOR WHERE APPUCBLE. 14. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCA UTILITIES REQUIREM IF APPCABLE. REFER TO PLANS TO GETERMINE IF WATER ENTS METER IS U REQUIRED. C. GAS PIPING 1. FURNISH AND INSTALL A COMPLETE GAS PIPING SYSTEM IF APPUCABLE. REFER TO PLANS TO DETERMINE IF A GAS SYSTEM IS REQUIRED. GAS LINES SHALL H E BLACK STEE SCHEDULE 40, ASTM A -53, WITH MALLEABLE N TS FORD - T / NGS FOR AND SMALLER, AND WITH WELDED JOINTS FOR 2 -i/2" AND LARGER. FURNISH AND INSTALL A GAS COCK. DRIP LEO, AND UNION CONNECTION TO EACH PIECE OF EQUIPMENT. SUPPORT PIPING B REQUIRED BY CODE OR REQUIRED BY LANDLORD CRITERIA, WHICHEVER IS MORE STRINGENT, GAS PIPING EXPOSED ON ROOF MUST BE PAINTED WITH RUST - INHIBITING PAINT. GAS PIPING INSTALLED IN RETURN AIR PLENUMS SHALL BE SLEEVED AND VENTED OR WELDED IN ACCORDANCE WITH THE LOCAL GB COMPANY, LOCAL CODE, AND APPLICABLE NFPA 54 CODES. TREAT! ING MENTS OF T AND PURGIHG HE TO OF Cr GA PIP N CO MPANY HALL , BE DONE ROM THE D LOCAL CO , AN APPLICABLE NFPA 54 CODES, UP TO FINAL CONNECTION POINT AT THE APPLIANCE. CONTACT AND COORDINATE GAS RVICE. METER AND REGUTOR REQUIREMENTS WITH THE LOC SE AL GAS COMPANY AND THE MALALL'S OPERATIONS ME MANAGER PRIOR TO BID. INCLUDE INSTALLATION COST G OF GAS S METER AND REGULATOR IN BID. END OF SECTION 15200 ABBREVIATIONS - PLUMBING AD ACCESS DOOR :SA AMERICAN DISABILITY ACT AFF ABOVE FINISHED FLOOR APP ACCESS PANEL CD CEILING DIFFUSER OR CONDENSATE DRAIN CFM CUBIC FEET PER MINUTE CI CAST IRON CO CLEANOUT CONT CONTINUE CONTR CONTRACTOR COTG CLEANOUT TO GRADE DET DETAIL DF DRINKING FOUNTAIN DL DOOR LOUVER DS DREAMSTEAMER DTR DOWN THRU ROOF DWG DRAWING (E) EXISTING EWC ELECTRIC WATER COOLER FCO FLOOR CLEANOUT FCU FAN COIL UNIT FD FLOOR DRAIN FPS FEET PER SECOND FS FLOOR SINK GAS GAL GALLONS GC GENERAL CONTRACTOR GPM GALLONS PER MINUTE HB HOSE BIBB HD HEAD HP HORSEPOWER INV INVERT LAV LAVATORY LB POUND LF LINEAL FEET MECH MECHANICAL MFR MANUFACTURER MTD MOUNTED MTR MOTOR (N) NEW N.C. NORMALLY CLOSED N.I.C. NOT IN CONTRACT N.O. NORMALLY OPEN N/A NOT APPUCABLE NTS NOT TO SCALE PUMP PO PRESSURE DROP PLBG PLUMBING POC POINT OF CONNECTION PRV PRESSURE REDUCING VALVE PSI POUNDS PER SQUARE INCH (R) RELOCATE RD ROOF DRAIN RPBP REDUCED PRESSURE BACKFLOW PREVENTER RPM REVOLUTION PER MINUTE SCH SCHEDULE SOV SHUT -OFF VALVE OR SCHEDULE OF VALVE UH UNIT HEATER LION UNLESS OTHERWISE NOTED UTR UP THRU ROOF WC WATER CLOSET WCO WALL CLEANOUT WG WATER GAUGE WH WATER HEATER WHA WATER HAMMER ARRESTER WT WEIGHT P EPA RATE APP I AND RE QUIRED. H B K CONSULTANTS, LTD 171 CHARRING CROSS DR S SUITE 1B WESTERVILLE, OHIO 43081 (614)882 - 1199 0 1 - Z U OW i HI wo o N Z tn0 Q !:: J • r 0 f b Q w J �� ST Z L • O :E • _� r LL OMQ O V10 REVISIONS: .ECEIVED CENT DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: 10/16/03 JS JS WDB PLUMBING SPECIFICATIONS DRAWING NUMBER: P01.1 T UNLESS OTHERWISE SPECIFIED, CONTRACTOR SHALL PROVIDE ALL NECESSARY EQUIPMEN., MATERIAL, LABOR AND SUPERVISION NECESSARY TO COMPLETE THE PLUMBING WORK IN ACCORDANCE WITH THE SPECIFICATIONS AND STANDARDS. 2 PRIOR TO BID, FIELD VERIFY EXACT SIZE AND LOCATION OF EXISTING WASTE PIPING BELOW SLAB, VENT PIPING ABOVE CEILING AND UP THROUGH ROOF AND COLD WATER SUPPLY PIPING ABOVE CEILING PRIOR TO COMMENCEMENT OF ANY WORK. AFTER INSTALLATION AND FINAL CONNECTION OF NEW WASTE PIPING BELOW SLAB, BACK FILL AND PATCH IN ACCORDANCE WITH THE LANDLORD'S CRITERIA REGARDING SUCH WORK. 3 CONTRACTOR SHALL FURNISH AND INSTALL ALL OF THE NECESSARY PLUMBING FIXTURES (SEE PLUMBING RESPONSIBILITY SCHEDULE ON E00.0) TO SERVE THE TENANT'S DEMISED PREMISES AND MAKE NECESSARY INSTALL ATION OF DOMESTIC WATER AND SEWER PIPING FROM TENANT DEMISED PREMISE TO CONNECTION PROVIDED BY LANDLORD. _ 4 SANITARY VENTS SHALL BE ROUTED TO THE EXISTING LANDLORD'S POINT OF CONNECTION WITHIN THE TENANT'S DEMI S£D PREMISES OR TO A POINT APPROVED BY LOCAL AUTHORITY. THE CONTRACTOR SHALL PROVIDE A CAPPED TEE FOR POSSIBLE FUTURE CONNECTION (IF REWIRED BY THE LANDLORD) CONTRACTOR SHALL COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD'S ROOFING CONTRACTOR, AS REQUIRED. VENT THRU ROOF SHALL BE AT LEAST 15 FEET AWAY FROM A/C UNIT FRESH AIR INTAKE. 5 SEAL AROUND Al. L PIPES PENETRATING FIRE SEPARATIONS WITH LISTED AND APPROVED SEAL MATERIAL. ONLY LISTED AND APPROVED SEALANTS AND METHODS FOR THE SPECIFIC USE WILL BE PERMITTED. 6 THE CONTRACTOR SHALL INSTALL ALL TOILET FIXTURES IN ACCORO_WCE WITH ALL CODES AND AS REQUIRED BY LANDLORD'S CRITERIA. 7 THE CONTRACTOR SHALL ENSURE THAT ALL SLAB PENETRATIONS WITHIN THE TENANT'S DEMISED PREMISES ARE PROPERLY SEALED AND REMAIN WATERTIGHT TO PREVENT ANY POSSIBLE DAMAGE TO OTHER TENANTS AND OR 70 THE BUILDING. FAILURE TO DO SO / SHALL BE AT RISK AND SOLE EXPENSE OF THE CONTRACTOR. B A MATERIA L SHALL NBE N NEW AND OF E COMMERCIAL GRADE. AANPD I BEAR . UNDERWRITERS LBORATORIE AND UIO LABELS WiiRE SUCH LABEL LNG PLES 9 PLUMBING CONTRACTOR TO FIELD VERIFY PROPER SLOPE OF EXISTING SEWER TO MAIN SEWER PRIOR TO ANY NEW PLUMBING INSTALLATION. 10 SANITARY PIPING 2 -1/2 AND SMALLER SHALL BE SLOPED A MINIMUM OF 1 /4 - PER FOOT OF RUN. SANITARY PIPING 3 AND LARGER SHALL BE SLOPED A MINIMUM OF 1/8 PER FOOT OF RUN. 10 ALL ROOF CUTTING, PATCHING AND FLASHING REQUIRED TO INSTALL THE PLUMBING SYSTEMS SHALL BE BY A LANDLORD APPROVED ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. COORDINATE ROOF PENETRATIONS WITH LANDLORD AND GENERAL CONTRACTOR. ITEM FIXTURE ROUGH - IN SERVICES DESCRIPTION REMARKS 0 ALL WAT VENT LI NES. DUCTW DRAIN LINES, SPRINKLER LINES, ETC. T SHAL B E ER OFFSET LINES BELOW P LATFORIA AND CONCEALED IN WALL ABOVE PLATFOfdA. DO NO ROUTE PIPING, ETC. THRq)GFI STORAGE SPACE ABOVE PLATFORM OR ABOVE ELECTRICAL E O CONNECT NEW SANITARY LINE INTO THE LANDLORD'S EXISTING SANITARY SERVICE AS S.M. INSTALL CLEAN OUT AT CONNECTION TO LANDLORD'S MAIN AND COORDINATE LOCATION AND TYPE OF COVER REQUIRED TO PATCH FLOOR FINISH WITH LSD&C'$ PROJECT MANAGER. NEW SANITARY LINE SHALL BE PRESSURE TESTED PER LOCAL CODES WITH A MIN11kW REQUIREMENT OF HOLDING 10 FT. W.C. FOR NO HOURS. O OFFSET 2' -0' AND EXTEND NEW VENT THROUGH ROOF. O CONNECT NEW COLD WATER LINE INTO THE EXISTING COLD WATER TAP. NOTIFY LSDID'S CONSTRUCTION MANAGER IF TAP IS SMALLER THAN SHOWN ON RISER DIAGRAM. O FATE PIPING AND INSTALL HO WAONR HEMMAR RRR IN THE DWATER I R LERD RRD TET WATER PIPING AS SHOWN ON THE WATER RISER DIAGRAM. WATER HAMMER ARRESTERS TO BE LOCATED IN AN ACCESSIBLE LOCATION. O6 ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. O INSTALL CONDENSATE DRAINS AND SECONDARY CONDENSATE DRAINS FROM ALL AHU'S AS $ROO sin M ON PLANS. MINIMUM DRAIN SI TO BE 1'. DRAINS SHALL BE EXTENDED AT A SLOPE OF 1 1/4' PER 40' TO THE MOP BASIN AS INDICATED BY PLANS. O RELOCATE EXISTING WATER METER. INSTALL IN LOCATION AS DIRECTED BY LANDLORD. REMOTE READER IF REQUIRED. SOIL WASTE OR SEWER S. OR W OR SAN PREsSuRE GAGE I_ByP� BACK FLOW PREV. is3 ACCESS DOOR DIT1 COMBINATION BALANCE 0 GATE VALvE `rr-- l•T.I GLOBE VALVE Ip BUTTERFLY VALVE j DRAM VALvE 1,1 CHECK VALVE III uNION I fzt I PLUMBING FIXTURE CD — CONDENSATE DRAIN C D SANITARY VENT V COLD WATER C W - - -- NOT WATER H W - -DG SHUT-OFF VALVE S 0 V —0— 0— FLOOR CLEAN -OUT C 0 — II WALL CLEAN -OUT 0 BRASS FLOOR DRAIN —0 RISE DROP POINT OF CONNECTION P.C.C. GAS PIPING a31VM 10H NBLVM 0'100 BOSOM 1N3A BOSOM L03E110M SOB _ �� WAT CLOSET TANK ER TYPE 1/2- -- — KOHLER'HIGHLME PRESSURE LITE' WHITE, PRESSURE ASSISTED WATER CLOSET, MODEL N0. K -3544 WITH ELONGATED WTREOU$ CHINA BOWL, 17 -1/2 MGH, WHIT E OPEN FRONT SEAT AND D MODEL N0. K- STOP FURNISH WITH BOLT CAPS AND CHROME SUPPLY STOP. I.6 GPF CAP HANDICAP TYPE LAV -1 I LAVATORY WALL MOUNTED 1/2' /2' 2 1 1/2' — _ KXRLER 'CHESAPEAKE' 20' z 18' LAVATORY, MODEL NO. K -1729. FURNISH MTH CDNCEALED ARM WALL HANGER, CHROME SUPPLY STOPS, CHROME P -TRAP FOR WHEELCHAIR H. KOHLER 'CORALAIS' FAUCET MODEL N0. K -15182 WITH POP -UP DRAIN. INSULATE P -TRAP AND SUPPLY LINES WITH 1/2' ARMSTRONG - ARMAFLEX PIPING MSULAWON OR EWVALENT. MOUNT AT HEIGHT DIRECTED BY THE ARCHITECT. HANDICAP TYPE OF ' I F AG FOUNTAI N 1/2' — 2' 1 1/2 — — OA9S BARRIER -FREE NO.N- REFRIGERATED DRINKING FWNTAIN MODEL NO. PAM. SEE M ANUFACTURER'S MSmuCDONS FOR PROPER INSTALLATION FOR ADa TYPE TOPE I� I 1 MOP SW 1/2' 1/2' 3 1 Tif — — FIAT MOP MOLDED STONE SERWCE BASIN MODEL NO. MSB -2424 WITH VINTA euMPERGUato. FURNIST WTH AMERGCAN STANDARD FAUCET MODEL NO. 6344.112 Wlm MTE(RAL VACWM BREAKER AND STOPS. (E) EXISTING (N) NEW (R) RELOCATE III... --III SPLASH BLOCK I I TANK TYPE WRIER HEATER 3 /4 . 3/4' — — — — a0. TH ,TEL,F -6, 6 GALLON, 1500 WATT, 120 VOL , 1 RiA Sc. SMI En UN. 1� 1 I FLOOR DRAM — — r 1 1/2' — — ZURN FLOOR DRAM YODEL N0. Z- 415 -6B. CASTIRON BODY, COMBINADDN I OUTlET LE CL AMP AND A IRIEL L Cp1AR. 3' BOTTW OUTLET Wm 6' ROUND NICKEL BRONZE $DRAINER MTH DEEP SEAL P_IRAP FIXTURE FIXTuRE UNITS a ,- DETAIL MARK WCO I WA LL OIEANOJT — _ _ _ _ — CAST IRON CLEANOUT TEE WITH BRONZE THREADED CLEANOUT PLUG. PLUG TO BE GAS AND WATER TIGHT. ZURN ZANB- 1460 -9 9' X 9' WALL ACCESS PANEL AND FRAME. SET RUSH TO FIN. WALL WITH SECURING LUGS. WHA WATER HAMMER ARRESTORS — — — — — SIDEF 650 SERIES OR EDUAL BY slow CHI PRECISION PLUMBING PRODUCTS, INC. red ED STORE )RE DESIC mited Parkway ie: 614.415.70 'www.LSL1nC _a FIXTURE SCHEDULE LEGEND AND SYMBOLS PLUMBING PLAN CONSTRUCTION NOTES : F : E PLUMBING CODED NOTES : D F - G H Y ( I� I [ 3/4 ; 1) 0 .1 11 ) 2,k, J I ,.____, STREAMER 41111 DREAM %IF Ind PROJECT INFORMATION: 0100688 THE LIMITED vv SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: RELOCATION /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND I GENERATION: 032FA LSD &C PROJECT #: 00043770 A/E PROJECT #: 03341/03132 111:11 FD CO ----- - - - - -- 0W . TYP I I r L � .) P03.1 o( Tm.) ® ® - I I WCO P 0 M 3 . 1 7YP.) I I MS " En car _ MA =0 I 91 o it UI DF 1 3 -I • ® / ® I : © FCO IiIV I A Q 3/4' DOM H2O 1 1/4' CO El 11111.111l0 1 O 13'- 6' A.F.F. 1 �[ ` I I L A __ O ie • ,y, 1 1/4' r aL l nor 9 9 7nn7 DATE ISSUED: 10/16/03 DESIGNED BY: KAS DRAWN BY: KAS CHECKED BY: WDB VERIFY ALL CONDITIONS IN FIELD PRIOR TO BIDS. E N AS S IV W PLUMBING PLAN DRAWING NUMBER: • ®2 1 PLUMBING PLAN T-0" I - RIMARY COND. DRAIN ROPE DOWN TO BORM SYSTEM D PERFOR Ut SHEET LEAD FLASHING MOP IN WITH ROOFING MATERIAL MATE AL iii TURN LEAD DOWN INTO STACK MIN. 12' WIN. ,2" / FLExIBLE FILLER / SLEEVE I O ' ! � ■■ �� •• II I WALL CLEANOUT W ACCE COVER I I LL I SLOPE CAP r UNION t2" MIN SLOPE FC, AHU OR WATER SOURCE HEAIPUNP 1' CLEARANCE ALL AROUND I. 4' 1 MIN � I � I 2 .. .. O �2 ... • 4 • • JJO .O•••JO. i �JJ.Ji•Oiii.Pi'OODi -Ji•- RE NON-COMBUSTIBLE STOPPING PIPE j BE SLEEVED AND LIQUID TIGHT. 3-MIN. II N I FLOOR SLAB ALL FLOOR PENETRATIONS MUST .: „ ROOFING MATERIAL ROOF GONS7RUCRON AS REOUIROED CONSTRUCT VENT STACK �� 3 "I MIN. � DRAM IN TRAP H-- 2' HIGH li CEILMG GALVANIZED SHEET METAL SECONDARY CONDENSATE DRAIN PAN TO ROPE TO DRAIN PIPE PIPING TO HAVE VISIBLE OVER SELECTED DRAIN LOCATION FOR WATER SEAL INCREASER WHEN REQUIRED .. III CONDENSATE DRAIN N.T.S. $ I WALL CLEANOUT DETAIL M PIPE FLOOR PENETRATION DETAIL VENT THRU ROOF DETAIL OODPO3IHVTRD H )ODPNO3aW DETAIL VACUUM BREAKER BY P.C. C ,• GATE/BALL VALVE BY P.C. ( TYP. ) 3/4' T & P R ELIEF VALVE BY P.. 3/4" RUN FULL SIZE TO MOP SINK. INSULATE ALL PIPING IN ACCORDANCE VA. SPECIFICATIONS _ HW . 3/! i_•_________ UNION BY P.C. (TYP) HEALER SEE SEALANT r-TE SLAB OR / SHE GRADE AT LOWER LEVEL LIJU ED STORE )RE DESK mited Parkway te: 614.415,70 'www.LSDnC _��__ • OF OS �- C.W. INN �) /SUPPL6 -' 1I RATED WALL AL L ON MSULATION (E) OR (N) PIPE $U�GAII w0� ANDS. (MW NOT RUN PIPE INSIDE WALL 1 COOK I WALL 1 ROUTE '� "”' 1 /2" CA SUPPLY 3 7W WALL I „id WATER PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFO. - -- �'� . ' I \ "� STRUCTURE AT UPPER LEVEL r . . A ?� TO TENANT'S a; j SANITARY SEWER , ' NON -$ALE I 2" WIDE, 20 GA. SHEET METAL BAND. SECURE 1 T O WALL FOR SEISMIC BRACING WHERE : 11 3 W BRAND FIRE :- 1 1 2' 1 L" AN 4 VALVE aN igc ► jj FLEXIBLE.' DED 1 2 -0 - WRH DRFAY SIFA I , � 2" SEAL BARRIER CP253R!R A CAULK- WIN. BEAD AROUND OUTSIDE FACERAIAL IIIIIIIII I REQUIRED BY CODE. UVINSULATFO - 1!L SYSTEM VA 1001 UTSI11 A7FD - 01 SYSTEM WL 5035 35p O L 4 BY P.C. gIBLE ��� PLATFORM BY - - - 1 DRAIN GENERAL CONTRACTOR S SEPARATE DRAINS O MOP SINK. - NOTE: INSTALLATION TO FOLLOW UL SYSTEM IV!. 1001 OR TO. 5039 AND BE A UL TESTED ASSEMBLY. 4EI" _..I 11181110 ROMEO PLAN viEBREA.. FLOOR ORB FUiISHED FLOOR if BEEP SEAL TRAP SECTION VIEW N.T.S. I N.T.S. N.T.S. G "DREAMSTEAMER" PIPING DETAIL \ T PIPE THRU FIRE WALL PENETRATION DETAIL r.� - /2"r DREAMSTEAMER 1 FLOOR DRAIN DETAIL IOODP03�FLDH L RESTROOM WATER HEATER DETAIL , lam BRASS CLEANOUT PLUG FINISHOOR CONCREAB BRASS COVER ADJUSTABLE HOU57NG �I , V i 3•' PROJECT INFORMATION: 0100688 THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: RELOCATION /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: 032FA LSD &C PROJECT #: 00043770 A/E PROJECT #: 03341/03132 ■■•■.. � (TW. )� , `\ ,� . ' \ �✓ � � �yL\ I N 1 _ /2- c ? t 21 s dM_ 1 � / �, I -1/2 ^ y�7 " O ` _ l2• t- I DF © 0.5 O ` ' I WC -1 ` ©� � 4 1 -1/2 CU I _• STRUCTURE A7 J UPPER LEVEL - —.._ I \ \\ \ \ \ \ / / /� \ \ / / \ \ / \ \ / \ \ � / / \ / // // / \ C / /\ / / /\ SEALANT TO TENANrS SANITARY SEWER / _ LOWER LEVEL 4 3" 2 W0 " I E A I MS I .. KEZEZTcOMNOTFETO 2 N.T.S. N.T.S. WASTE AND VENT PIPING DIAGRAM FLOOR CLEANOUT DETAIL - I . F OR I/2 ® �'� T /2" Dr _ 0.5 3/4" 3/4' Ili ` 7-1° EMI Q I I�t /2" Y / ,/2 444CCCCC"'"' �' , 1.5 3/47 \ ` C_y ' • W L 2 `.. ��1 O6 (TYP.) � ' ( �� Q -- 7.5 , �\ 3 /4' \� I /rte: a pRFAMSTFAMER BAL VAL VE ON WAL `� 1) EAM STEAMER � T /2 .k.„,. \ ! !♦ / ' 4" / � / � ' / © m ' /1/2' 3/4" © o Fp4 /4T ® �' p "T �'EP(i/R(`(( O REVISIONS: REQUIRED c...4mE , 7n DrT 2 Anna cam - DATE ISSUED: 1 0/16/03 DESIGNED BY: KAS DRAWN BY: KAS CHECKED BY: WDB PLUMBING ISOMETRICS & DETAILS MS 2.25 SEE SHEET 'P02.1 FOR PLUMBING CODED NOTES O DRAWING NUMBER: P03 1 N.T.S. --- N ' T ' $ ' J DOMESTIC WATER PIPING DIAGRAM N.T.S. A B. SHOP DRAWINGS C. GAL... OR BLACK Limit IRON WITH BRASS SEAT . ALL WORK SHALL BE INSTALLED PER N.FBA NUMBER 13, STATE 8 LOCAL BUXOM MAXIMUM HEAD SP.!. 12 FT. CODES, FIRE DEPARTMENT, LANDLORDS INSURANCE UNDERWRITER a. FREEBIE MINIMUM 18' CLEARANCE BETWEEN STOCK AND SPINKLER HEAD, AND ALL OTHER APPLICABLE LOCAL CODES. 1. PROVIDE SPRINKLER HEADS UNDER ANY OBSTRUCTIONS EXCEEDING 48' N y SPRIKLER CONTRACTOR TO PREPARE PLANS FOR SUBMITTAL 70 AU. REQUIRED AUTHORITIES. LENGTH OR WIDTH UNLESS THIS P1» WILL SUFFICE SPROIOER SMALL BE TESTED FIN! A MINIMUM OF 2 HOURS AT 200 FBI. R REFER 1D SPECIE/31016 FOR ADpT10NAL REQUIREMENTS. SHOP DRAW. SHALL BE SUBMITTED TO FIRE RATING INSPECTION BUREAU FOR APPROVAL BEFORE FOREMEN. 11. VALVES ARE NOT ALLOWED IN THE SPRRD(LLR SYSTEM. 4. PROVIDE SIGNED CERTIFICATE OF COMPLETION. COPIES 70 BE GIVEN TO TENANT'S 1y CONTRACTOR SHALL INST. AN INSPECTOR'S TEST CONNECTION. THE Diu CONNECTION ARCHITECT. INSURANCE REPRESENTATIVE AND PROJECT OFFICE MUST BE INSTALLED OFF NE MOST REMOTE SPRINKLER, AS PHYSICALLY POSSIBLE, FROM THE SEXNKLER SUPPLY YAW IA CAPPED OUT. CONNECTION EXAM IN THE DEMISED 5. HOED � SPINIER LINES � HIGH � ��• PREIM56. INSPECTOR'S LEST CONFECTION SHAU. RE EQUIPPED WITH ONE RidF (1' CORROSION RESISTANT SFRIT -OFF VALVE. AND SMOOTH BORE CORROSION RESISTANT OUTLET DRAIN WITH HOSE BIBS CONNECTION FOR DISCHARGE TO SUITABLE SANITARY SEWER • UNLESS OTFERWISE ND1ED ON ARC111IECNRAI DRAWINGS, SPRINKLER MEADS SHALL RE AS BY LANDLORD OR AS SPEGFlED ON pGWIMG. VERIFY CORRECT SPINIER TYPES, PRIOR TO PROCEEDING WITH WORN. COORDINATE WITH ARCHITECT. 13. FASTENING AND/OR SUSPENSION DEVICES MUST BE ATTACHED TO THE BURRING STRUCTURE ONLY. / FlED TURFY CONDITIONS. PRIOR TO PROCEEDING WITH WORK. 13. 7. RAGE ANY DUSTING SPRINKLER PIPING 10 CLEAR HEY/ CEI18M, HEIGHTS. RAGE cum SPUNKIER NMI TO CLEAR NEW DUCTWORK. COORDINATE WITH MECHANMJI'. 14, PROVIDE VALVED DRAIN WITH HOSE THREAD AT ALL LOW POUR RI SPRINKLER PIPE . LOW POINT, F COKE.. WITH A CEDING MARKER AND PROVDE ACCESS TO THE VALVED DEWS. 8. TENANT SPRINKLER SUBCONTRACTOR SHALL VERIFY THE FOLLOWING WITH LANDLORD AND MT 15. LL MATOIALS A AID EDpp UNDER THIS SECTION 9MLL DE NEW ART LISTED BY FEND MEASURIUDIT PRIOR TO DESIGN OF SPRINKLER SYS•IEYB: UNDERWRITES LABORATORIES, INC, FOR FIRE PROTECTION SYSTEM INSTALLATION AID APPROVED BY LANDLORD AND ALL AUTHODTES HAVRE JURISDICTION a. M OF TENANT ST FEE SERVICE YADT STUBBED VERTICALLY. TENANT SPACE. AND COVERT/WC CODES b, S EA OF STUB-IN BOTH RIO M STUB AND TO TENANT 16. ALL HEWS ARE TO BE APPROVED TYPE AND SPACED IN ACCORDANCE WITH NEPA 13' 9, EMIR SPRINKLER SUBCONTRACTOR SHALL INSTALL HIS SYSTEM °DEPLETE, INCWDING 115191 PRIOR TO CONNECTING 70 MALL SPRINKLER SYSTEM. TESTING SWILL BE 17_ COORDINATE SPRINKLER WORK W FIRE/SAFETY CONTRACTOR, APPROVED BY THE FlRE DEPARTMENT AND LANDLORD'S REPRESENTATIVES. FINAL CONNECTION iO LANDLORDS SPRNKN THE DEMISED PREMISES YAp1 SHALL NOT RE MADE UNTIL THE SPRNKIER HEAD SWELL MATCH LANDLORD STANDARDS, SELECTION SHALL RE SU ENTIRE SYSTEM PREMISES S TESTED AND READY FOR SERVICE AND APPROVAL AND BASED ON 1}E FOLLONNG: W'IM'PS REVIEW ENCIOBU F AN SMALL n NFA C ON THE MALL SIDE OF 1OIANPS SIOREFROIIT RE, 10. LISTED BELOW ARE YDBYUM REWUEYENTS FOR SPRINKLER SYSTEM DESIGN AND PATCH LANDLORDS TYPE INSTALLATION, SYSTEM NDLO SHALL BE I CARRI DESIGNED. SYSTEM MA MUST ALSO COMPLY WITH LL 13, U ARUE LOCAL INSURANCE CARRIERS REQUIREMENTS. MALL REWIREtlE1T1S 0. REM TO Opt SIRES /NON -SALES HEADS. TO SPECIFICATIONS AND ALL APPLICABLE LOCAL OR STATE CODES. SMOKE SHALL RE INTERFACED CORN BUILDING FIRE /WE SAFETY AND 19. SPR000ER SYSTEM / 3 000 S.F. SPRINKLER LEADS .20 GPY SF OVER AN UIREI®R5. P' 1� ��' �� / AREA. MUST SYSTEM IF REQUIRED. REFER TO LANDLORD TENANT CRITERIA D RE / b. OCCUPANCY CGSSIFMATION ORDINARY HA7ARIl, GROUP II. 130 SOFT. PER HEAD IN SUITES AREA, a IOU SUM COVERAGE PER SPRINKLER: STOCK ROOM. 100 SOFT. PER HEAD RI STOCK RO H B K CONSULTANTS, LTD 171 CHARRING CROSS DR S SUITE 113 WESTERVILLE, OHIO 43081 (614)882,71m � r = - _ _ Iy�v + a .,/O;J�, S _ , /) ,,.,�. _ � - ...ES 6/10 /O� � O DIVISION 15 - MECHANICAL SECTION 15000 1. 1X15 FlRE PROTECTION CONTRACTOR SMALL PREPARE DETAILED SHOP SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER. DRAWINGS AND CALCULATIONS FOR NIS WORK SUBMIT 51X (6) D. VKTAUIIC TYPE COUPLINGS ARE ACCEPTABLE, WHERE APPROVED COPIES TO (;ENTERAL CON FOR APPROVAL BY CODE AND THE IANOLORD. 2. THIS FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMITTING 3. AFIRE PROTECTION SYSTEM TAP S NORMALLY FURNISHED BY THE LANDLORD. VERIFY IN FIELD PRIOR TO BID. SPRITE. SPACING COORDINATED DRAWINGS, HYDRAWC CALCULATIONS, HEAD TYPES AND SHALL NOT MELD 130 SQ. FT. IN - SALES' AREAS AND 100 SQ. COLORS TO ALL AUIHORRIES HAVING JURISDICTION FOR APPROVAL - COMPLY WITH LANDLORD'S DESIGN NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE BEEN RECEIVED. FT. IN "STOCK" AREAS L - 16' i2 BASIC MFCHANICAI REQUIREMENTS FOR SPECIFICATIONS REFER TO MECHANICAL SECTION 15000 ON SHEET P01.1. • TYPICAL SPRINXLER HEAD LOCATION FOR T-BAR CEILING. SECTION 15300 CODES IF MORE STRINGENT. PIPE CRITERIA AND LOC JU. ADNG SMALL BE BASED ON NFPA ORDINARY HAIARD. 3. A COPY OF THE LETTE OF APPROVAL FROM THE UJ+OLORD'S INSURANCE RATING BURLA S HALL BE FORWARDED TO THE MIDLORD'S 4. ALL SPRINIOER LINES SHALL BE INSTALLED CONCEALED, AVOID. AGENT AND TO ISO PROJECT MANAGER. 4. DUCTS. C15, PIPES. STORAGE DECK ETC. WITH LIG FIRE PROTECTION CONTRACTOR SHALL PREPARE COORDINATED SHOP G EQUIPMENT AND INSTALLATION DRAWINGS INDICATING THE LOCATIONS OF ALL SPRINKLER NERDS, PROTECTION SPRINKLER LINES, LIGHTS, DIFFUSERS, GRILLES AND REGISTERS COSTS 1. SPRINKLER HEADS PRIOR TO INSTALLATION. A ALL SPRINKLER HEADS SHALL BE NEW (EXISTING HEADS E 5. WHERE POSSIBLE. REWORK THE EXISTING SPUNKIER SYSTEM TO MEET EXISTING LSD. STORES ARE NOT TO E REPLACED LIMIER THE NEW REQUIREMENTS OF THIS DESIGN, UPON APPROVAL OF PROJECT NOTED OTHERWISE, E.L, F.Y. LISTED AND APPROVED MANAGER RELOCATE ALL MAINS AND BRANCHES COMPONENTS INTERFERING WITH CEILING AUTOMATIC SPRAY TYPE AS MANUFACTURED BY GLOBE, CEILING HEIGHTS, EQUIPMENT AND MAJOR COMPONENTS INCLUSIVE OF RELIABLE. STAR, OR YWNG. ADJACENT TENANTS MID MALL COMMON AREAS. REMOVE ALL UNUSED THE PIPING. THE B. ALL SPRINKLER HEADS SHALL BE WED FOR 165'F UN1 6. FURNISH AND INSTALL A VALVED TEST CONNECTION MAN INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL ACCESSIBLE LOCATION FOR THE SPRINKLER SYSTEM AS REWIRED OR JOB CODES. REQUESTED BY THE MALL LOCAL INSPECTOR OR INSURANCE C. ALL SAPS FLOORS HEADS INCLUDING TRIM AND COVER WILL BE CARRIER. COORDINATE LOCATION WIN LSDAC'S CONSTRUCTION TO FACTORY APPUED WHITE COLOR FINISH VERIFY HEAD TYPES MANAGER AND LOCAL FIRE PROTECTION OCIAL PRIOR TO ROUGH- AND COLORS WITH LSDWC'S PROJECT MANAGER AND SUBMIT WITH IN. SPRINKLER DRAWINGS FOR PERMIT. 7. WHEN COMPLETED, THE ENTIRE FIRE PROTECTION PIPING SYSTEM SHALL BE HYDROSTATICALLY TESTED AS REWIRED BY THE RULES AND D. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS: REGULATIONS OF THE AUTNORmES HAVING JURISpIOTION. SYSTEM FORA 1. 'SALES' AREA SPRINKLER HEADS ARE TO BE WHITE SHALL SHOW NO SIGNS OF LEAKAGE OR OTHER DEFECTS. THE RECESSED PENDANT WITH WHITE ESCUTCHEON. BASE BID CONTRACTOR SMALL BE RESPONSIBLE FOR DAMAGE TO THE WORK OF AND SHALL BE RELIABLE Y ODEL - F1'. ALTERNATE BIDS MAY THE OTHER CONDUCTORS OR TO THE MM. OR TO ITS BE BASED ON VIKING YICROMATIC YODEL 'Y' OR CONTENTS, PEOPLE, ETC., CAUSED BY LEAKS O ANY OF THE GRINNELL YODEL 'F972 AND MUST BE APPROVED BY THE EQUIPMENT INSTALLED BY HIE. ALL AIRS OR REPLACEMENT OF LSD. PROJECT MANAGER PRIOR TO ORDERING AND DAMAGES SHALL BE AT THIS CONTRACTORS EXPENSE INSTAWTOK JURISDICTION, AND LANDLORD, AUIHO REP 2. 'NON- SALES' AREA SPRINKLER HEADS ARE TO BE PENDANT 8. PROPERLY COMPLETED AND SNEED 'SPRINKLER CONTRACTORS THE HYPE ROUGH BRASS TIMEX. MANUFACTURED BY STAR, MATOOAL AND TEST LS H A VI CERTIFICATES" SHALL BE NNNI DD A TO THE PLANS RELIABLE, GRIkNELL OR wan ONLY SPRpIQER PJTIES HANG ISDC'S CO. PROJECT MANAGER. ' AREAS SHALL BE UPRIGHT R WA B' -0 TO STRUCTURE" IN CDLINGS 0 WALLS BELOW 3. HEADS IN 'OPEN 9. SPRINKLER MEADS LOCATED AVOID HYPE HEADS. NON -SALES HEADS SHALL NAVE A ROUGH ABOVE THE FINISHED FLOOR AND ABOVE STORAGE DECKS ARE TORE USE BRASS FlNHI. SALES AREA HEADS SHAM HAVE A FACTORY CONC TO PAINTED WHITE FEIN 10. NRNCH N pF UE 10 O. HYPE 'ABC FIRE 2RC ISRATIN, 2. PIPING: WITH IONS O IF REWIRED, AND AT U10 CABINETS FIELD A U LIT RC • RATING. A SCHEDULE eD, BLACK STEE PIPE, ASTIR A -53 FOR FERROUS LOCATIONS TO RE ESTABLISHED IN 'THE FIELD BY MRCS RISERS PROJECT MANAGER AND THE LOCAL FEE PROTECTION OFFICIAL IN BID PIPING, WELDED AND SEAYLE55, ANSI 8 -36 -10-70 FOR MAAYUY TRAVEL DISTANCE BETWEEN EXTINGUISHERS SHALL BE 75 WROUGHT STEEL PIPE. FEET OR LESS AS REWIRED BY LOCAL CODES. B. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND S.J.ER SCREWED OR CAST IRON FLANGED END OF SECTION 15300 ' ` FIRE PROTECTION ��� �������� ��� -� � ���'��� � - _ ,,:;; ������`��'•�� 12� A. E OF WORK SCOPE CONTRACTOR 1. THIS CO IN MUST USE A LANDLORD APPROVED FIRE CONTRACTOR TO PERFORM ALL FIRE PROTECTION WORK ALL E THIS CONTRACTORS BID. FIRE PROTECTION MUST BE INCLUDED CONTRACTOR MUST COMPLY WITH ALL SECTIONS OF 7X18 SPECIFICATION AND INCLUDE SANE IN BID. 2 7X15 CONTRACTOR SMALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL T0. FURNISHING, INS LE , COMPLETION AND TESTING OF ALL WORK FOR THE SPRINKLER SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: A. INSTALLATION OF NEW WET SPRINKLER SYSTEM AS REQUIRED PROVIDE COVERAGE IN ACCORDANCE WITH EXISTING CONpTONS, NFPA -13, LOCAL CODES, LANDLORD'S CRITERIA AND INSURANCE CARRIERS FOR THE MALL AND WIRED. B. TAPS, RISERS, LATERALS, BRANCHES, VALVES, ALARMS, SPRINKLER HEADS AND ALL COMPONENTS REQUIRED COMPLETE SYSTEM. C. DESIGN DRAWINGS, HYDRAULIC CALCUUTIONS SUBMITTALS APPROVALS. D. PERMITS, FEES. AND CHARGES. E TESTS AND TEST CERTIFICATES. F. FIRE EXTINGUISHERS. 3. ARCHITECTURAL, STARTING WORK THIS CONTRACTOR SHALL E ARCHITECNRAL SSTRUCTURAL, MECHANICAL AND ELECTRICAL AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE FIRE PROTECTION SYSTEM MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO INTERFERENCES AND CONFRONTATIONS. CONTRACTOR SHALL APPROVED RE SPRINKLER FIRE RAN HES AND SUBMIT FOR ULATIOG EXISTING FIRE SPRINKLER BRANCHES AND SUBMIT CALCUU TO LSD. PROJECT MANAGER'S SATISFACTION. S PROJECT MANAGER UPON REQUEST OR REWORK SYSTEM TO LSD 4. RELOCATION OF XSISTIN MAINS, LATERALS, BRANCHES AND TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED PROPOSAL SECTION 15300 - FIRE 18' - TYPICAL 24 - X 24'CE IL LNG TILE TYPICAL 24 - % 2 / TILE O O o _ / , ID G i 0 N - i z 0 % E? - CC o ^ m ^ f- _ ,�, T.: 0 - >_ G KT lU Z_ Z _ EO �_ Z T Z 0 y ( \ ^/, Q o J YPICAL SPRINYLER HEA D LOCATION FOR T -BAft CEILING. 24' _ - .. .. TYPICAL 48 -% 24 CEILING TILE ® -S.�G (T � ,, JOINTS FOR PIPES LARGER THAN 2 INCHES. ® FIRE SPRINKLER NOTES C SPRINKLER OCATION DETAILS L1 mH LIMIT d /b /a ST( Three Li Telepho http: // PROTECTION _ x U I- ¢z w vA H E? K L M c 5 g„,,6, I F: I I I ° ° A 0 0 I O i i t 1 f 0 0 0 1 : : : : ° o o O O O n n „g "es CLLo 1 _..- :.........: ..._..:_._.....:. .......:....... ._:......._ ;.....__._._. -..... ..........,..... ° o l I ..................... i "-':---"i ( ' i � i 9 s 0 ° O ° ( Oo i i ° 1 1 1 I 1 : 1 :1 1 : ° 1 0 0 ° 0 ° ° II O � 0 `j ° J ' LL-----.. i s ........... E'. 1....._----._........._- 1 ..... ...__...._._......... -- 6 J TA WrIw cT O J W W .. I L? -, - W ='5 W 1 v 1 r a 3i it E� i�w iii tl w I Q. I y � E0 fn Y71 J PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: RELOCATION /DOWNSIZE I PACKAGE: DESIGN TYPE: ALMOND GENERATIO1 LSD &C PROJECT #: 00043770 A/E PROJE v ° I _.....__.._... Ii� n 0 _ : v 66 . . . .... ._ _ �i ' 0 o ...... 1 o I . o / \ : I ° r6 u a� ° I : 0 : 0 � o ° ° ° • I o I I r 1J 0 o ® . a� u ° u o� ° 0 0 3 O 16 - 0 0 0 0 o o ° ° - ° ° i 0 i I i j - j O ' . o° 0 0 0 u ® � 0 O 0 1 JC 1 p a ____:c z 0 0 0 0 0 I I I i I n �� ■f LEGEND AND SYMBOLS SYMBOLS . UPRIGHT SPRINKLER HEAD 0 SEMI- RECESSED PENDENT SPRINKLER HEAD 0 CONCEALED SPRINKLER HEAD 0 PENDANT SPRINKLER HEAD PORTABLE FIRE EXTINGUISHER 0 , 4 0 F 9, /J F REVISIONS: GEWIRFU BY: oA J - u 11GT 2 1 11107 •w0�.nsro.w�w�.o,�s�,a. DESIGNED ISSU ES GNEDU B 1 0/16/03 D BY: JS CHECKED BY: WDB SPRINKLER PLAN & SPECS. RI4 RF N� VERIFY ALL CONDITIONS IN FIELD PRIOR TO BIDS. ` �. E '/iii // N „ c5. VP W DRAWING NUMBER: FIRE SPRINKLER HEAD PLAN .. 1/4" .. 1'-O" A F 02.1 m G r- > z CO TJ 13 XI p Z r- r m 23 MATCH LINE — H PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 -11 9 • • • • ' I ' • • • • • • • • 111111 F N lil LJ II 0100688 SCOPE: RELOCATION /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: 032FA LSD &C PROJECT #: 00043770 IA /E PROJECT #: 03341/03132 1�1 MATCH LINE FOS Limited brands LIMITED STORE PLANNING, INC. d /b /a STORE DESIGN & CONSTRUCTION Three Limited Parkway • Columbus, Ohio 43230 Telephone: 614.415.7000 • Fax: 614.415.7340 http: / /Www.LSDnC.LimitedEtrands.com DIVISION 15 - MECHANICAL SECTION 15000 BASIC MECHANICAL REQUIREMENTS A. NOTE THE ABBREVIATION LSDAC WHEREVER R APPEARS IN THESE MECHANICAL DRAWINGS AND /OR SPECIFICATIONS SHALL REFER TO UNITED STORE DESIGN AND PLANNING . ANY REFERENCE TO TENANT'S PROJECT MANAGER OR FURNISHED BY ANY OF THE ABOVE REFERS TO LSDAC. 2. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED READ THE SPECIFICATIONS ANO REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF HIS SUBCONTRACTORS WITH ALL DIVISION OF WORK. R IS THIS CONTRACTORS RESPONSMIDY TO PROVIDE HIS SUB- CONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 4. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THIS WORK TO COMPLY WN THE LSDAC SCHEDULE AND THE PROJECT COMPLETION DATE. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY REPS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS ACT SHALL SEPARATELY AND QUALIFIED IN THE THE CONTRACTORS BID. . SUBMITTAL OF RD SHALL SERE AS KNOWLEDGE ON KNOWLEDGE OF DUSTING O E AND ANY MODIFICATIONS WHICH ARE REQUIRED D TO MEET T ThE THE INTENT OF THE DRAWINGS E T SPECIFICATIONS. FAILURE VISIT THE SHE DEC NOT REUSE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF HIS WORK REFER TO RESPONSIBILITY SCHEDULE ON SHEET ENO OF THIS SET FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR 1.5 WHICH MAY AFFECT THE BID. 3. 5. B. GENERAL REQUIREMENTS 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT. SERVICES, TOOLS. TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE MECHANICAL SYSTEM. SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR SDAC SHALL BE PROVIDED BY THIS CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND THE LSDAC PROJECT MANAGER, AS REQUIRED. THE DRAWINGS AND CIFICATIONS AR INTEDD TO SUPPLEYEM UCH OTHER AND ANY SPE MATERIAL OR LABOR CALLLD FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT NEM MENTIONED THE CALLED ANY MATERIAL N AICH S IS IC NCNOR SHOWN ON THE DRAWINGS NOR ED D FOR OR IN DIE N THE SPECIFICATIONS, W WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE T ANO WHICH USUALLY INCLUDED WORK OF K SIMILAR CHARACTER, SHALL B INC IN W RE FURNISHED FURNISHED AND INSTALLED W ALLED AS PART OF CONTRACT. 3. WHERE THE DRAWINGS DR SPECIFICATIONS CA11 FOR REPS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTAWNG THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL WORK IN THIS SECTION SHALL BE INSTALLED SO AS M BE READILY ACCESSIBLE FOR OPERATING SICING MAINTAIING. D REPAIRING. THIS CONTRACTOR IS RESPONSIBLE ERV FOR , PROVIDIN SUF SERVICE ACCESS TO ALL EQUIPMENT. 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD CONSTRUCTION PRACTICES. 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS. AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEWINDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. 7. THIS CONTRACTOR SHALL D ALL CUTTING, CHASING AND CHANNELING REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY LSDAC PROJECT MANAGER AND THE LANDLORD. ALL PATCHING SWILL BE BY G.C. AND SHALL MATCH THE SURROUNDING SURFACES 8. THE MECHANICAL CONTRACTOR SHALL MAKE ALL FINAL MECHANICAL CONNECTIONS AS REQUIRED FOR A COMPLEM AND OPERATING SYSTEM. a. THE MECHANICAL CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR M CONTACT THE HVAC EQUIPMENT MANUFACTURER'S REP. FOR START UP. (SEE "CARRIER GENERAL NOTES" ON SHEET E00.0). C. (PARAGRAPH OMITTED) D. CODES ALL WORK SHA CONFORM TO NDLORSD' I S TERU, THE STATE'S, AND LL HEALTH CITY'S AND LOCAL THE LA CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES M REQUIREMENTS. I T h H. THIS CONTRACTOR ALL SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICTi-Er CODES, ANYINANCES ARE REGULATIONO THIS CONTRACTOR A ALL INCLUDE ANY CHANGES NO QUA INC. DE CODES IN THE HID AND IF EH CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE AS A SEPARATE ONE ITEM IN THE BID. AFTER CONTRACT IS S QUALIFIED ED, CHANGE ORDERS ED B FOR Y LSDA INCREA SED COSTS DUE TO CODE ISSUES WILL NOT BE ACCEPT E. LICENSES, PERMITS, INSPECTIONS A FEES 1. . -. PERMITS. NSPECTI NS, ANORFEES REOUIRED RE!ATEDTTO HIS WORK 2. FURNISH 70 E LSDAC'S PR OJECT MANAGER ALL CRTIFICATES N OF INSPECTION TH AND FINAL INSPECTION APPROVAL AE T COMPLETIO OF PROJECT 2. F. TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS 1 OR EN TH SPECIFICATIONS. MANUFACTURERS DRAWINGS EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY LSDAC'S PROJECT MANAGER THROUGH SHOP DRAWING SUBMITTAL PRDESS FOR ACCEPTANCE PRIOR TO INSTALLATION. THE USE OF ANY RIZED EQUIPMENT SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO LSDAC PROJECT MANAGER FOR APPROVAL SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR LSDAC PROJECT MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP AND/OR THE SIGNATURE OF THE GENERAL CONTRACTOR AND THE SUB - CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WIT A WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAXERS. G. GUARANTEE THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER HIS CONTRACT AND SHALL HAKE GOOD. REPAIR OR REPLACE AT HIS OWN EXPENSE, ANY DEFECTIVE WORK. MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY A S t PROJECT MANAGR. EXTENDED WARRANTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. 2. A 12 GUARANTEE TO DATE ACCEPTANCE. THIS CONTRACTOR SHALL WARRANTY THE INSTALLATION OF THIS EQUIPMENT AND MILL BE RESPONSIBLE FOR ANY DAMAGE AND /OR MALFUNCTION CAUSED BY THE INSTALLATION. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM. H. RECORD DRAWINGS 0. THIS CONTRACTOR SHALL MAINAIN ONE S ET OF DRAWINGS ON SHE DRAWING VE AS:EEKLY TO T RECORD ALL 1,Dz ONS FROM CONTRACT A. LOCATION B. REVISIONS, ADDENDUM. AND VALVES ( CHANGE ORD RS. DUCTS. C. CO DIT ON A DEVIATIONS RO ED EQUIPMENT AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THIS C SHALL MA ANY FI CORRECTIONS TO DRAWINGS AND CERTI THE ACCURACY OF UCH PRINT BY SIGNATURE THEREON. THE ENERAL CONTRACTOR TO RECORDS E THESE RECORDS AT DIRECT EXPENSE PRIOR TO FINAL PAYMENT. MECHANICAL SPECIFICATIONS 1 DISCREPANCIES IN DOCUMENTS DRAWINGS TPLANS. SPECIFICATIONS, AND DETAILST ARE THE MECHANICAL AND SYSTEMS. S.E THE E G .A I S NND INTENT OF THE MECHANISPL SCAT WHERE DRAWINGS. COSTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES C NCT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN R PRIOR TO SUB ET J GENERAL ONTRACTOR IS R IS RESPONSIBLE S TO ADVISE &C S PROJECT ROJECEC T MANAGEAGE R, WRITING, OF S TO CONTRACT RACT D D D P P ROJE PRIOR SUBMISSION BID. VARIATIONS OTHERWISE, CT MANAGER'S S ER'S A BID. INTERPRETATION OF CONTRACT DOCUMEOCUME NTS M OR ON CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. J. PHASING REQUIREMENTS 1. 1132 CONTRACTOR IS T O INC IP ALT ALL NECESSARY STORE'S SERVICE REQUIRED S KEEP LER OPERATING PHASE OF THE HVAC, PLUMBING AD SPRINKLER SERVICE IN OPERATION. CONTRACTOR MUS T SCHEDULE IN WRITING WITH LSDAC'S isZTJE00VM OFETHE RVACEPWMBING ORNFIREEPROTPECTRON SY�STYEMS. K. DEYOUTION 1. THIS CONTRACTOR MALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK MT THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. 2. THIS CONTRACTOR SHALL INCLUDE. AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING HVAC UNITS, HMRONIC PIPING, REFRIGERANT RECAPPJRE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT TO BE REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF / /FLOOOR PATCHED/ REPAIRED TO MATCH EXISTING STRUCTURE �KISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES. ABANDONED PIPING AND /OR DUCTWORK MUST BE REMOVED TO POINT CIF ORIGIN. CONFIRM ME EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL L SLEEVES 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR CONTRA CTOR MUST COORDINATE INATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY BOORS OR WALLS. ALL SLEEVES AND OPENINGS THROUGH FIRE TED WALLS AND /OR 'MTV" SHALL FIRE SEALED WITH N T OR RAZED L S. AS NE RTV" M AI FOAM, FIRE FIRE RATED SEALANTS OR DUAL, SO AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE N0. 22 U.S.G. GALVANIZED STEEL MINIMUM. 2. Y. HANGERS 1. HANGERS SHALL IHCLLDE A!1 MISCELLANEOUS STEEL SUCH AS ANGLE O IRN, BANDS, C -CLAMPS WITH RETAINI CUPS CHANNELS, RANGER RODS, ETC., NECESSARY FOR THE INSTALLATION NG , OF WORK. 2. RANGERS SHALL BE FASTENED TO BUILDING ST, CONCRETE, OR PERMITTE, BUT NGT SO MUST N TT C HE FERN EEL METAL RD IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR. AND IN ORDER TO SUPPORT DUCTWORK PIPING, THE CONTRA B MUST IEDTALL TRAPEZE TYPE HANGERS RS OR B SUPPORTS S WHICH SHALL DO BE LOCATED WHERE THEY NOT INTERFERE WITH ACCESS AND LLA, VALVES. AND OTHER EQUIPMENT. HANGER TYPES INSTALLATION AND INSTALLATION METT HODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE DEAFER DIAM ETER OF INSULATION. INSTALL 6" DUNG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELECTRICALLY SEPARATED. R FINAL HVAC INSPECTIONS 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PUCE. LSDAC SHALL HAVE AN INDEPENDENT HVAC CONTRACTOR INSPECT THE FINISHED HVAC INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PUNS, SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS AND SPECIFI CATION REQUIREMENTS. END OF SECTION 15000 SECTION 15500 HEATING, VENTILATION, AND AIR CONDITIONING L SCOPE OF WORK 1. THIS CONTRACTOR SHALL FURNISH ALL TABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY INPUD AND INCIDENTAL T0, THE _ FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE HVAC SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE UNITED TO THE FOLLOWING: A. HVAC UNITS. ALL RELATED EQUIPMENT AND ACCESSORIES (UNLESS NOTED OTHERWISE). B. DUCTWORK, FITTINGS, (GG(((DAMPERS, AND INSULATION. BI I E CURBS, ROOFING, U STEEL FRAMING R FORSUPPORT APPLICABLE, REFER TO PUNS). F. TESTING, ADJUSTING, AND BALANCING. G. KEEPING A RECORD SET AND PREPARE AS- BUILTS DRAWINGS. 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL VISIT THE JOBSAE AND EXAMINE THE ARCHITECTURAL STRUCTURAL MECHANICAL AND ELECTRICAL PUNS AND SPECIFICATIONS SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS, AND EQUIPMENT ITH OTHER CONTRACTORS TO AVOID OID INTERFERENCES FERENCES AND D CONFRONTATIONS. RELOCATItlN V EXISTING DUCT WEANS OR BRANCHES TO NEST STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL 8. HVAC EQUIPMENT 1. PRIMARY HEATING AND AIR CONDITIONING UNITS ARE TO BE FURNISHED BY LSDAC AS SCHEDULED UNLESS NOTED OTHERWISE. REFER TO PUNS FOR REQUIREMENTS. ALL EQUIPMENT SHALL INCLUDE WA FIVE RRANTY (5T YEAR COMPRESSOR AND TEN (10) YEAR HEAT EXCHANGER 2. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 3. 4. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. SECONDARY DRAIN PANS ARE REQUIRED TO BE INSTALLED BENEATH ALL INDOOR AIR CONDITIONING EQUIPMENT WITH THE EXCEPTION OF VAV BOXES. SECONDARY PANS ARE TO CAPTURE POTENTIAL LEAKS FROM THE ENTIRE UNIT. PROVIDE CONDENSATE PUMPS, AS REQUIRED. CONDENSATE SHALL BE DIRECTED TO MOP SINK OR AS SPECIFIED ON PLANS. C. EQUIPMENT FURNISHED BY UNITED STORE DESIGN AND CONSTRUCTION 1. THE FOLLOWING EQUIPMENT IS FURNISHED BY LSDAC AND INSTALLED BY THIS CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. REFER TO RESPONSIBILITY SCHEDULE AND PUNS FOR APPLICABILITY. A. HVAC UNITS 8. TOILET EXHAUST FANS. C. BASEBOARD, CABINET AND UNR HEATERS. D. DIFFUSERS; GRILLES AND REGISTERS. E. 7EMPERAT CONTROLS ALL DUCTWORK, ROOF DPEk!DS AND C NCESSARY TO PROVIDE A COMPLETE TOILET EXHAUST SYSTEM SHALL APS BE E ERNISHED ANLI INSTALLED BY THIS CONTRACTOR. D. METAL DUCTWORK - D FIBERGLASS DUCT ALLOWED 1. D DUCTWORK SHALL BE FABRICATED PMOR TO JOB SITE VISIT AND APPROVAL BY THE GENERAL CONTRACTOR. A SKETCH MUST BE SUBMITTED INDICATING DEVIATIONS FROM DESIGN AND MUST BE APPROVED BY LSDAC'S PROJECT MANAGER PRIOR TO FABRICATION OR INSTALLATION. 2. EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR AND ROUND DUCTWORK WITH GALVANIZED STEEL, IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS" OF THE LATEST EDION. WHERE OTHER CODES ARE ENFORCED, (IL UPC, BOLA, ON S LECK TANDAR BE TDS. HE MOST STRINGENT CODE FOR DUCT CONSTRICTI 3. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING PRESSURE CLASSIFICATIONS SBPLY DUCTS: 2 W.G., POSITIVE RETURN AND EXHAUST DUCTS 2" W.G. NEGATIVE EXCEPT WHERE OTHERWISE INDICATED, USE DUCT SEALANTS OF THE FOLLOWING PRESSURE CLASSIFICATIONS SUPLY DUCTS: CU55 RENRH AND EXHAUTT DUCTS CUSS IN ACCORDANCE WITH THESE CONSTRUCTION AND SEALANT PRESSURE C1A5501CATI0N, MAXIMUM DUCT AIR LEAKAGE WILL NOT EXCEED 5% AS REQUIRED FOR FINAL AIR BALANCE APPROVAL 4. ROUND DUCTWORK SHALL BE GALVANIZED STEEL WN SPIRAL LOCKSEAY CONSTRUCTION FOR ALL SIZES 14" DIAMETER AND LARGER. ROUND DUCTWORK SIZES 13" DIAMETER AND SMALLER MAY BE MO- M CONSTRUCTION. ALL SNAP -LOCK SEAMS SHALL BE SEALED AS DESCRIBED IN THESE SPECIFICATIONS. ROUND FITTINGS SHALL BE GALVANIZED STEEL WITH SENT WELDED AND BONDED CONSTRUCTION. ROUND SPIRAL GAC STEEL LCTWORK MAY BE USED IN P CE REGT RO AR EUCPWORK IN HORIZONTAL T FREE AREA WHEN ARE COUNT CLEARANCES PERMITS AND ALL SUP LY FLEE AREA LS MAINTAINED, WNN THE FOLLOWING EXCEPTION: ALL SUPPLY AND RETURN DUCTWORK WITHIN IS FEET OF THE AIR HANDLER MUST BE RECTANGULAR AND INTERNALLY ONO. . ONE A TRANSITION 1Y THE DIRECTION OF THE AIRFLOW TO SIRAL HAS BEEN DUNE, DUCT WILL NOT E ALLOWED TO REVERT TO AE SP KE T CH AN. CHAR RDUND GUET SUBSTITUTION WILL NVER PUCE, SUBMIT A SKETCH AND CHART SHOWING PROJECT EQUIVALENT ROUND CONVERSIONS OF RECTANQU DUCTWORK MD. DMD. PROJECT MANAGER'S GER'S FOR APPROVAL FA PRIOR TO FABRICATION OR INSTALLATION. 6. INSTALL FACTORY MANUFACTURED DOUBLE THICKNESS TURNING VANES IN A WC RIGHNA. T ANGLE ELBOWS IN MAIN DUCT PER LATEST EDITION OF TUE 7. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEITS INDICATED IN %TACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION ON USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPF J RT F DUCTS AT A MAXIMUM INTERVAL OF 16 BEET AND U LOORPON VID S . NO WOOD SHALL LL BE USED SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND R SEISMIC BRACING AS REQUIRED BY STALE AND ND LOCAL S CAL CODES R BY LANDLORD. 8. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE AS MINI 1- 1/2 "X1 -1/Y X1/8" STEEL ANGLE FRAMES AT EACH SIDE OF OPINING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. 9. ALL JOINTS AD SEAMS SHALL BE SEALED WITH 2" WIDE, GLASS - FIBER- FABRIC REINFORCED TAPE JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. LIQUID SENATES BY UNITED MCGILL CORP., DOW CORNING, MIRACLE ADHESIVES AND SUREBOND INC. WILL BE ACCEPTED IN LIEU OF TAPE. 10. SOFT STOMR M BU GASKET WITH ADHESIVE BACKING SHALL BE TO USED TO SEAL FLANGED JOINTS. 11. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. 12. PROVIDE ACCESS TO ALL YOTORQED DAMPERS, FIRE DAMPERS, CONTROLS, AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION IS EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY LSDAC'S PROJECT MANAGER PRIOR TO INSTALLATION. IN HARD CEILINGS, LAY -IN SUPPLY AND RETURN MR DIFFUSERS, GRILLES AND REGISTERS WM1 PLASTER FRAMES MAY BE USED AS ACCESS LOCATION WHEN WITHIN 3' -0" OF DEVICE. 13. ALL DUCTWORK SHALL BE INSTALLED WITH INSIDE CLEAR DIMENSIONS AS NOTED ON DRAWINGS WHERE DUCTWORK SIZE IS LARGER THAN CONNECTED DEVICE `'R. VAV BOX, DIFFUSER, REGISTER) SMOOTH DUCT TRANSITIONS ARE M TAKE PLACE JUST PRIOR TO DEVICE CONNECTION. REFER TO DETAIL MD -22. E. MEDIUM PRESSURE DUCT 1. WHERE DUCTWORK IS SPECIFICALLY NOTED AS MEDIUM PRESSURE, IT SHALL BE CONSTRUCTED IN ACCORDANCE WITH NACHA STANDARDS FOR REQUIR A PRESSURE RATING ED LANDLORD. OF BY 4 INCHES WATER COLUMN MINIMUM OR CRU TCH AS 2. ALL GAUGES AND REINFORCEMENT MUST MEET WITH THE LATEST EDITION OF SMACNA STANDARDS FOR MEDIUM PRESSURE DUCT AND WITH THE LANDLORD'S CRITERU. 3. CONNECTIONS TO THE LANDLORD'S MEDIUM PRESSURE DUCTWORK SHALL BE MADE WEAN "LO -LOSS" SADDLE TEE TAPS OR AS OTHERWISE REQUIRED BY THE LANDLORD. ALL OTHER KEYS TROY METAL DUCTWORK SPECITION SECTION APPLY TO THIS SECTION, WHH THE EXCEPTION TH ALL TEDIUM PRESSURE DUCTWORK OUST BE WRAPPED INSULATION, NOT ONE.. F. VIBRATION ISOLATION DEVICES 1. SPRING VIBRATION ISOLATION DEVICES SHALL BE FURNISHED AND INSTAL IN ALL SUPPORTS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS, , ETC.) AND STRUCTURE IBOUTON TUI B SIZED ACCORDING TO DAD HA lit' 1" OETLLCTIOR VIBRATING EQUIP Zen STRUCTURE SMALL E ISOLATED -WITH RUBBER AND SPRING DEVICES. - VIBRATING EQUIPMENT SUPPORTED -- ` FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. 2. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN AVOID SELECTINGRURDINGG DEVICE " THE AOJU ISOLATO ST FGR R. PROPER ALIGNMENT AND LOADING. " 3. CHECK HANGER ROD ERE FOR ALLOWABLE LOADS AT THE ISOLATING DUC DUCTS, ADD A S T NTE T CPER AND LOWER ATTACHMENTS TO STRICTURES, DUCTS, EQUIPMENT, ETF 4. CONSULT MANUFACTURER FOR APPLICATION DATA. G FLEXIBLE CONNECTIONS 1. FLEXIBLE COLLARS SHALL BE FURNISHED AND INSTALLED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT (FANS, AIR HANDLERS, ETC. ) AND DUCTS OR CASINGS. ALSO, FURNISH AND INSTALL FLEXIBLE CONNECTIONS WHERE DU CM CROSS BUILDING EXPANSION JOINTS. 2. FLEXIBLE CONNECTORS SHALL BE CONSTRUCTED OF NEOPRENE -COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FlEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. H. FLEXIBLE AIR DUCE 1. FLEXIBLE AIR DUCT SHALL BE F" INSULATED CLASS 1, UL LASTED AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL ((PLASTIC, CLOTH. ALUMINUM MUST ADHERE TO LOCAL CODES AN 8 LANDLORD'S REQUIREMENTS AND BE INCLUDED . SUCH IN THE BID. 2. FLEXIBLE AIR DUCT SHALL CHED PR DETAI ON TH DRAWINGS MIL AIR DUCT MAY ONLY BE BE ATTA USED I VERTICAL LS APPOCATI ON. 3. FLEXIBLE DUCT SHALL NOT EXTEND OVER 4' -0" IN LENGTH AT ANY ONE LOCATION. 1 SUPPLY AIR TAKE -OFF FITTINGS I. FURNISH AND INSTALL CONICAL , TAPERED OR 45 DEGREE SADDLE TAKE OFFS ERY VAIN DUCTWORK TO ROUND BRANCHES. INSTALLATION SHALL BE PER SYACNA LATEST EDITION. J. DAMPERS I. WHERE DESIGNATED, FURNISH AND INSTALL MANUAL LOCKING QUADRANT VODNE CONTROL DAMPERS WITH HANDLE OPERATORS AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. DURODYNE MODEL N0: K SERIES QUADRANT. 2. OPERATING HANDLES ON ALL DAMPERS SHALL BE TAGGED WITH A MINIMUM 18" LONG ORANGE MARKER TAPE. 3. WHERE ACCESS TO BALANCING DAMPER IS RESTRICTED, A REMOTE DEVICE, MANUALLY OPERATED SHALL BE USED. UNITS SHALL BE ORDERED THREE WEEKS BEFORE INSTALLATION TO ALLOW FOR DEUVRY LEAD TIME. K. FIRE/FlRE SMOKE DAMPERS 1. INSTALL PRIMARY FIRE DAMPERS WHERE INDICATED OR REQUIRED BY CODES. DAMPERS SHALL BE DEMGND FOR HORIZONTAL OR VERTICAL FLOW OF AIR AS REQUIRED. FIRE DAMPERS SHALL BE 01 LABELED AND MEET ALL CODE REQUIREMENTS. 2. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF THE AIRSTREAM AND A 165 DEGREE F FUSIBLE LINK, TYPE 8, AS MINIMUM. FURNISH AND INSTALL ACCESS DOORS AS NECESSARY. 3. FURNISH AND INSTALL ALL NECESSARY FRAMING AND SLEEVES FOR DAMPER YOUDNG PER UL AND CODE REQUIREMENTS. 4. EIRE SMOKE DAMPERS SHALL BE FURNISHED AND INSTALLED WITH ELECTRIC POWERED MECHANISM. COORDINATE WN ELECTRICAL CONTRACTOR FOR POWER REQUIREMENTS. L DUCTWORK INSULATION 1. FURNISH AND INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NEPA 900. 2. DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR MENTORS. ALL SUPPLY AND RETURN AIR RECTANGULAR DUCTWORK SHALL BE INTRNALLT %MATD NM 1" THICK, 1 -1 2 IB. DENSDT UNER C =N T 75 DEGREE WHEN A CO - UCTED RETURN AI A R D UCT CLOSEST TO THE AIR UN INDICATED oN THE D W TUGS ONLY THE 15TO BE IRS OF THE RETURN R AIR D SURFAC E EXPOSED TO AIRSTREAM S TO TREAM LINER IS TO HAVE A COATED SURFACE EO PREVENT EROSION. APPLY ADHESIVES AND MECHANICAL TRANSVERSE ES AS RECOMMENDED BY SAMNA AND THE MANUFACTURER TO TO PREVENT UNER SEPARATION TH AD FROM THE DUCT. Ail TRANSVERSE EDGES TO BE COATED WITH ADHESIVE. 3. ALL ROUND DUCTWORK, OUTSIDE AIR DUCTWORK AND MEDIUM PRESSURE DUCTWORK SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF 1 HAPOR &RItIE IS TO BE cATININY DUCT SYSTEM. ALL JOINTS MUST BE OVERLAPPED AND TUCKED SO THAT NO INSULATION FIBER IS VISIBLE EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS AND OTHER PENETRATION. LINED DUCTWORK SPECIFIED ELSEWHERE AND EXHAUST DUCTWORK IS NOT EXTERNALLY INSULATED UNLESS SPECIFICALLY NOTED. 4. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVEDPD RATING OF NO HIGHER THAT 50 WHEN TESTED IN ACCORDANCE WITH ASTI C 411, OR AS REQUIRED BY LOCAL CODES. Y. HYDRONIC PIPING I. FURNISH AND INSTALL A COMPLETE HTDRONIC PIPING SYSTEM IF APPLICABLE REFER TO PUNS TO DETERMINE IF A HYDRNIC SYSTEM IS REQUIRED. 2. PIPING A HYDRONIC PIPING FOR CHDJJ71 WATER, CONDENSER WATER W BE ASTY 53 SCHEDULE 40 AND O HEATING A7ER SHALL EA� B LACK STEL PIPE WITH PWN ENDS INSTALL STEEL PIPE WITH WEEDED JOLTS WHERE PIPE IS D JOINTS RICH AND URGER INSTALL STEEL PIPE P RHREADEDNTS AND FITTINGS. INSTALL TYPE "K" COPPER PIPE FOR 2 INCH AND SMA LLER PIPP E. PROVIDE DIELECTRIC UNION BETWEEN S NC DISSIMILAR METAL ALL PIPING SHALL D' IN STRICT CONFORMANCE IS EQUIPMENT WITH A MOST ASR, AND UN ONSS REQUIREMENTS, FLANGES VER STRINGENT. UNIONS EIANES ONS OR MUST WHICHEST BE USED AT EQUIR CONNECTIONS WHERE SERVICE OR REMOVAL MAY BE REQUIRED. ALL PIPING AND EQUIPMENT SMALL BE PRESSURE TESTED WITHOUT LEAKAGE AT A MINIMUM PRESSURE OF 125 PSI. C. ALL HYDRONIC PIPING AND EQUIPMENT CONNECTED TO THE HVAC PIPING SYSTEM SWILL BE C.N. AND FLUSHED. REMOVE, CLEW, AND REPLACE STRAINER SCREENS FILL TENANT'S SYSTEM WITH DOMESTIC WATER AND VENT ALL PIPING AND EQUIPMENT PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM. CONTRACTOR SHALL NOT FILL TENANT'S SYSTEM WITH WATER FROM THE UNOLORO'S SYSTEM UNLESS SPECIFICALLY INSTRUCTED TO DO SO FROM THE LANDLORD'S FIELD REPRESENTATIVE. ANY RUNS THRU A CHASE OR SHAFT WILL BE DONE WITH FEWEST JOINTS POSSIBLE USING THE LONGEST LENGTH OF HARD COPPER PIPE AVAILABLE SHOULD A JOINT BE REQUIRED, CONTRACTOR SHALL WAKE ALL EFFORTS TO KEEP THE JOINTS IN ACCESSIBLE AREAS D. PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM, CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION FROM THE LANDLORD'S FIELD REPRESENTATIVE, THAT ALL TESTING, FLUSHING, AND PROPER FILLING OF THE TENANT'S SYSTEM HAS BEEN COMPLETED IN ACCORDANCE TO THE LANDLORD'S REQUIREMENTS AND THAT THE TENANT'S SYSTEM IS READY 70 BE CONNECTED TO THE LANDLORD'S SYSTEM. 3. VALVES A. GATE VALVES, 2 -INCH AND SMALLER: CLASS 150, BODY AND UNION BONNET OF ASSN B 62 CAST BRONZE WITH THREADED OR SOLDER ENDS, INTEGRAL SEAT, RENEWABLE SOLID BRONZE WEDGE DISC, RISING STELA, SCREWED BONNET AND RE- PACKABLE UNDER PRESSURE BALL VALVES ARE ACCEPTED AS AN EQUAL SUBSTITUTION. B. GAFF VALES, 2 -1/2 INCH AND LARGER: C1A55 125 CAST IRON BODY, RENEWABLE BRONZE SUES AND SOD. WEDS DISC, RISING STEP, FLING. ENDS, AND RE- PACKABLE UNDER PRESSURE C. SWING CHECK VALVES, 2 -INCH AND SMALLER: CLASS 150. CAST BRONZE BODY AND CAP CONFORMING TO AST I B 62 WO HORIZONTAL SWING, ',PATTERN, RENEWABLE BRONZE DISC, AND HAVING THREADED OR SOLDERED ENDS D. SWING CHECK VALVE, 2 -1/2 INCH AND LARGER: CLASS 125 CAST IRON BODY AND BOLTED CAP, HORIZONTAL SWING, RENEWABLE BRONZE DISC, FLANGED ENDS AND CAPABLE OF BEING REFITTED WHILE THE VALVE REMAINS IN THE UNE. E COMBINATION BALANCING AND SHUT -OFF VALVES: BELL At GOSSM CIRCUIT SETTER WITH LOCKING SET POINT. A CIRCUIT SETTER BALANCE WHEEL MUST BE INCLUDED WITH 0 M MANUAL TACO OR GRISWOLD ARE CONSIDERED AS EQUAL 4. PIPING SPECIALTIES / / A INCH NPT FITTINGS TU RECEIVE PLUGS EITHER A TEMPERATURE OR PRESSURE PROBE, 1 B INCH O.D. FITTING AND CAPS SHALL BE B.. WITH VALVE CORE OF NORDEL, RATED AT 400 PSIG, 0 TO 200 DEGREES F. 4. STRAINERS - "Y" PATTERN STRATUS, 125 PSIG CAST IRON BODY NM PERFORATED STAINLESS STEEL SCREEN THREADED LER FOR 1 INCHES AND SMAL FLANGED FOR 2 -1/2 INCHES AND LARGER. SCREEN OPENING SIZE AT 0.033 INCH FOR HEATING AND 1/8 INCH FOR CHILLED OR CONDENSER WATER PROVIDE NTH BLODOWN VALVE WITH HOSE END FITTING. 5. INSULATION A ALL VFU NIC PIPING FOR CHILLED AND /OR HEATING S PECIE! O Y NOTED BE U S % VAW WATER FO P FITTTI 9 ES TO 2 INCHES, INSULATE WITH 1 INCH THICK K=G23 0 75'F) Fl INSULATION WITH 1/ LL SE CE JACKET AND VAPOR BARRIER. INCHES INSULATE W I �2 INCH THICK K 0.23 AND 75FGER, ) WITH -1 FIBERGLASS INSULATION WITH ALL SERVICE JACKET AND VAPOR BARRIER. B. INSULATION AT ALL HANGERS FOR PIPING 2 1/2 !INCH. AND LARGER SHALL BE HARD AND NON - COMPRESSIBLE. C. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 TO CONFORM WITH ME REQUIREMENTS OF THE NBA. D. PROVIDE ZESTON OR EQUAL INSULATION FITTINGS FOR ALL TEES, ELLS OR SPECIALTY FITTINGS 6. GENERAL INSTALLATION A. INSTALL WATER LIMNS WITHOUT PITCH. USE ECCENTRIC REDUCING COUPLINGS AT CHANGES IN SIZE WITH THE TOP OF PIP. AT SAME ELEVATION. B. BRANCHES TO UNIT BELOW MAIN TO BE TAKEN FROM BOTTOM OF MAINS AT A 45 DEGREE ANGLE, PITCH DOWNWARD TOWARD UNITS. BRANCHES TO UNITS ABOVE MAINS TO BE TAKEN FROM TOP OF MAINS AT A 45 DEGREE ANGLE PITCHED UPWARD TOWARDS UNITS. PITCH NOT LESS THAN 1" TO 10 FEET. C. SEE MECHANICAL DETAIL DRAWINGS FOR APPLICABLE DETAILS N. REFRIGERANT PIPING: 1. THIS CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE REFRIGERANT PIPING SYSTEM BETWEEN THE INDOOR FAN UNITS AND OUTDOOR CONDENSING UNITS. REFER TO PUNS TO DETERMINE IF A REFRIGERANT SYSTEMS REQUIRED. 2. PIPING A. REFRIGERANT PIPING SHALL BE TYPE "L" HARD DRAWN COPPER NITROGEI CHARG�D. TUBING SHALL NE CLEAN, CAPPED AND 0. ALL FITTINGS AND JOINTS SHALL BE WROUGHT COPPER OR CAST BRONZE ANSI B16.22). A COPPER TO COPPER JOINTS SHALL BE BR ED WITH ACOLL PPER- PHOSPHORUS ALLOY AND ALL OTHER JOINTS SHALL BE BRAZED WITH SILFOS -5 ALLOY. C. ALL ELBOWS ARE TO BE LONG RADIUS TYPE. 3. INSTALLATION A SUCTION ON SHA NAE ADEQUATE LIFT TRAPS AND/OR DOUBLE SUCTIO N RISE RS TO MEET THE REQUIREMENTS OF FIELD CONDITIONS AND EQUIPMENT MANUFACTURER'S JOI B RAZE NDATI E BRAZE ALL JOINTS W SILFOS -5 STARTING NI THE INDOOR UNIT AND WORKING SO THE OUTDOOR UNIT. THE SEALS ON THE OUTDOOR E U SHALL BE BROKEN LAST. A NITROGEN BLEED E EVED SHALL USED ALL BRAZING AND ANY TIME THE SYSTEM S ALL OPEN. ALL OPEN ONES SHALL BE CAPPED AND SEALED BEFORE LEAVING THE SITE DURING CONSTRUCTION. YE. PRESSURE TEST FOR LEAN WITH AN INERT GAS UP TO 245 PSIG. REDO LEAKING JOINTS AND RETEST UNTIL SYSTEM IS TIGHT. EVACUATE ATE E ENTIRE SYSTEM TO 200 MICRON OF TO MERCURY. 2 CHARGE SYSTEM WN 25 P51 R -22 AND A INERT GAS GAS TO 245 PSI AND RETEST SYSTEM. ENERGIZE CRANK CASE NEATEN 24 REARS PRIOR TO STARTING EROM TO ENSURE LIQUID ALL REFRIGERANT LIQUID TH ID IS OUT OF THE COMPRESSOR. C. URN COMPLETION OF TESTING, BUT BEFORE THE REFRIGERANT PIPING INSULATION S B APPLIED, THE PIPING MUST INSPECTED BY A REPRESENTATIVE OF THE LOCAL GOVERNING AUTHORITY AS NECESSARY. D. IN THE REFRIGERANT SUCTION ONES AND CONDENSATE LANES ES WITH WITH ARMSTRONG 1 INCH THICK PIPE W. FLAME AYS E SPREAD RATING OF NOT MORE THAN 25 AND A SPOKE E D FL EVELGPED RATING OF NOT MORE THAN 50 IN ACCORDANCE DARN INDUSTRY STANDARDS DO NOT NOT GAS LIQUID ONES OR ANY HOT GAS BYPASS. INSULATE THE 4. INSPECTION A. CONTRACTOR MUST PREPARE AND SUBMIT A COMPLETE PIPING SCHEMATIC TO THE LOCAL MANUFACTURER REPRESENTATIVE FOR APPROVAL PRIOR TO BEGINNING INSTALLATION. UPON COYP.ON OF PIPING, THIS CONTRACTOR MUST CALL THE LOCAL REFRESENTATIVE FOR FIELD INSPECTION OF WORK PERFORMED . ALL EMS FOUND TO BE INADEQUATE FOR PROPER PERFORMANCE BY MANUFACTURER REPRESENTATIVE MUST BE CORRECTED. THIS INSPECTION IS PERFORMED AT LSDAC EXPENSE. 0. LABELS /PIPE MARKERS 1. FURNISH AND INSTALL PIPE IDENTIFICATION MARKERS ON ALL PIPES INSTALLED UNDER THIS CONTRACT. MARKERS SHALL BE A MINIMUM OF 1 -1/2" X 8" AND IDENTIFIED IN ACCORDANCE WITH THE BACKGROUND AND LETTER COLON ISSUED BY THE AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). 2. PIPING SHALL BE IDENTIFIED AS FOLLOWS: CHILLED WATER RETURN, CHILLED WATER SUPPLY, CONDENSATE, HOT WATER RETURN, HOT WATER SUPPLY, CONDENSER WATER RETURN, CONDENSER WATER SUPPLY, REFRIGERANT LIQUID, REFRIGERANT SUCTION, AND DIRECTIONAL ARROWS. ALL IDENTIFICATIONS MUST BE VISIBLE AT EQUIPMENT. P. CURBS FOR SUPPORT 1. THIS CONTRACTOR WILL FURNISH AND INSTALL ALL NECESSARY CURBS REQUIRED TO INSTALL ALL HVAC DUIPNENT AS DESCRIBED ON THE DRAWINGS. CURBS SR rr 5 Tel MINIMUM OF 8" (SEE UF "LOCAL AREA REQUIREMENTS REM HIGH, O THE A SME MANUFACTURER TA THE VET P S UNLESS ARE OTHERWIS E ALL CURBS MUST IS INSTALLED PENETRATIONS THE LANDLORD'S EXISTING R ARE LEVEL ALL THAT TOP OF SO CU BS STRUCTURE SHALL BE DONE IN ACCORDANCE AC TOR MUS THE T REC EIVE GUIDELINES L SD AT THIS CONTRACTOR'S EXPENSE. THIS CONTRACT RECEIVE LAC PROJECT MANAGER'S WRITTEN APPROVAL BEFORE ANY WORK TAKES PULL THIS CONTRACTOR IS ALSO RESPONSIBLE FOR ALL SEISMIC, HURRICANE OR OTHER SECURING DEVICES REQUIRED ECUIRED BY LOCAL OR OTHER CODES. 0. TESTING, ADJUSTING. AND BALANCING 1. TESTING, ADJUSTING ANC BALANCING OF ALL WORK SHALL BE MADE BY AN INDEPENDENT CONTRACTOR WHO IS A CURRENTLY LICENSED ASSOCI ATED AIR BALANCING COUNCIL (AABC) EZ NATIONAL NO OTHER BALANCING BUREAU (PNIEBBI BALANCING CONTRACTOR NO BALANCING OTHER WORK REPORTS WILL M UST COMPLETE ANE A D DONE IN ACCORDANCE WITH ALL THE MOST RECENT WORK M A TD DUNE THE MOST STANDARDS OF THEIR SOCIETY AND A MINIMUM SHALL REV I K THE INFORMATION AS SHOWN IN THE STS R BALANCE CHEC REVIEW . PAYMENT NT O ALL COSTS FOR TESTING TING AND AND BALANCING ANCING NCING SHALL BE INCLUDED IN THE BID. HOWEVER, R WILL THE G.C. THAT WILL CONTRACT T CL DIR DIRECTLY WITH THE AIR BALANCING COMPANY. 2 FINAL TESTING ADJUSTING AND BALANCING REPORT MUST TS TO BE COMPLETE AND SUBMITTED WITH FINAL CLOSE-OUT DOCUMEN LSDAC 1 WEEK PRIOR TO MERCHANDISIiNG DATE 3. THE HVAC CONTRACTOR SHALL BE PRESENT FOR AIR BALANCE TO VERIFY ACCESSIBILITY YO ALL DEVICES, VERIFY ALL OPERATING SEQUENCES AND INSTALL NEW FILTERS IN ALL UNITS JUST PRIOR TO THE AIR BALANCE THE COMPLETE AIR BALANCE SHALL TAKE PUCE WITH OUTSIDE AIR DAMPERS IN MINIMUM POSITION, EXCEPT AS NOTED OTHERWISE. HVAC CONTRACTOR SHALL ALSO INSTALL A NEW SET OF FILTERS ONE DAY PRIOR TO MERCHANDISING. 4. BALANCE LANDLORD MEDIA QUANTITIES TO WITHIN 5% OF THAT INDICATED ON THE DRAWINGS. ANY REQUIRED CHANGES IN SHEAVES, BELTS OR PULLEYS NEEDED TO ACHIEVE SPECIFIED FLOW RATES SHALL BE PERFORMED BY THE HVAC CONTRACTOR WITH NO ADDITIONAL COST TO LSDAC. ALL CONT SEQUENCES SH ALL BE TESTED (IN TERLOCKED O EQUIPME SMOKE DETECTORS, SMOKE EVAC ATION, ECON MIZER, ETC.) AND OPERATING STATUS RECORDED IN THE BALANCE REPORT. AIR BALANCING CONTRACTOR IS TO CONFIRM OVERRIDE OF MINIMUM OUTSIDE AIR INTAKE UPON C MONITORING CONFIRMATION. FOR CO2 MONITORING CONTACT, SEE A BALANCE COVER SHEET E00.0 7. THREE COPIES OF THE BALANCE REPORT SHALL SUBMITTED THROUGH THE GENERAL CONTRA BE TOR TO LSDAC F OR APPROVAL THE GENERAL CONTRACTOR SHALL VERIFY THE COMPLETENESS OF THE REPORTS PRIOR TO SUBMITTING TO LSDAC. SUBMIT ONE COPY ER FINAL APPROVED AIR BALANCE REPORT TO MALL GENERAL MANAGER 8. THE BALANCING CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANCING FUNCTIONS REQUIRED FOR THE SYSTEM DESIGNED ON THESE DRAWINGS. ALL SYSTEMS UNABLE TO BE COMPLETELY BALANCED AT THE TIME OF ORIGINAL BALANCE MUST BE BALANCED IN FUTURE AT NO ADDITIONAL EXPENSE TO LSDAC THE BALANCING CONTRACTOR SHALL RECHECK ANY ITEMS THAT LSDAC DEEMS NECESSARY AT NO ADDITIONAL COST TO LSDAC. END OF SECTION 15500 O 24 ABBREVIATIONS - HVAC AMERICAN AIR BALANCE COUNCIL AIR CONDITIONING UNIT ABOVE ACCESS DOOR APPROVED FIRE DAMPER ABOVE FINISH FLOOR AIR HANDLING UNIT ACCESS PANEL AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR CONDIONING ENGINEERS BACK DRAFT DAMPERS BELOW BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BRITISH THERMAL UNIT PER HOUR CAPACITY CEWNG DIFFUSER OR CONDENSATE DRAIN CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING, COOLANT CONNECTION OR CONNECTOR CONTINUOUS CONTRACTOR COEFFICIENT OF PERFORMANCE COMBINATION FIRE /SMOKE DAMPER CONDENSER WATER RETURN CONDENSER WATER SUPPLY DRY BUD, DECIBEL DEGREE DETAIL DIAMETER DIMENSION DISCHARGE DOOR LOUVER DOWN DOWN THRU ROOF DRAWING EXHAUST AIR EXHAUST AIR GRILLE EXHAUST AIR REGISTER ENTERING AIR TEMPERATURE ELECTRICAL CONTRACTOR ENERGY EFFICIENCY RATIO EXHAUST FAN EFFICIENCY EXHAUST GRILLE ELECTRIC ELEVATOR ENCLOSURE EXTERNAL NT EXTERNAL STATIC PRESSURE ELECTRIC WATER COOLER E EXHAUST EXISTING FAHRENHEIT FAN COIL UNIT FULL LOAD MAPS FLEXIBLE FLOOR FEET PER MINUTE FEET PER SECOND GAS GALLONS GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE HEAD HORSEPOWER HEATER HEATING VENTILATING AND AIR CONDITIONING HOT WATER RETURN HOT WATER SUPPLY //ASIDE DIAMETER INCH KILOWATT LONG LINED DUCT POUND LINEAR FEET LINEAR DIFFUSER HAXIMUP THOUSAND BTU PER HOUR MINIMUM CIRCUIT AAPACITY MOTORIZED DAMPER MECHANICAL MANUFACTURER MINIMUM OVER CURRENT PROTECTION MOUNTED MOTOR NEW NATIONAL ENVIRONMENTAL BALANCING BUREAU NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN NOT APP... NOT TO SCALE OPPOSED BLADE DAMPER OUTSIDE DIMENSION OR DIAMETER OPENING OUTDOOR AIR PUMP PRESSURE DROP PLUMBING POINT OF CONNECTION PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH RETURN AIR RETURN AIR GRILLE RETURN AIR REGISTER RETURN GRILLE RELATIVE HUMIDITY REVOLUTIONS PER MINUTE SUPPLY AIR SUPPLY AIR GRILLE SUPPLY AIR REGISTER SCHEDULE SENSIBLE SUPPLY FAN, SQUARE FOOT SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION SHUTT-OFF VALVE STATIC PRESSURE SQUARE SQUARE FEET STAINLESS STEEL TEMPERATURE TRANSFER GRILLE TOTAL STATIC PRESSURE THERMOSTAT TYPICAL UNDERCUT UNIT HEATER UNLESS OTHERWISE NOTED UP THRU ROOF VARIABLE AIR VOLUME VENTILATION, VENTILATOR VARIABLE FREQUENCY DRIVE VENT THRU ROOF WATT WET BUD WALL CLEANOUT WATER GAUGE WEIGHT S EPA RgT APP RE Q 11 IREC H B K CONSULTANTS, LTD 171 CHARRING CROSS DR S SUITE 1B WESTERVILLE, OHIO 43081 S SYRYE &1OI v / 0 0 Co --o I ^c ji'Eu „„ DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: z 0 • o C U E U m Z D r U _ CC TE LV N : ' C zz zps' J o - E OZ CC Wc3 7. OWTn 0 O L.LI _ m om z W C VE O C r) a C) m m >Z - 10/16/03 - J � F t .0 0 10/16/03 JS JS WDB MECHANICAL SPECIFICATIONS DRAWING NUMBER: M01.1 4 • • rw 4 y SON sr sr £o /9l /O l o v 0 0Z � -- 0 rn -4 r '. n E5 z 0 0 CP JAL r � W z V Z 0 171 > 0 ▪ 'O m 7C O 0 .. m Z - - 4 VZ011111 (1tnu;ur. 41381111181 MINIM Nrld OINV14331111 -4 cp cD 3 1, :y n i n 0 C cr cn 0 "6 . w G.; 0 &ilia OIL a ...... %NOON • = sN MIA] d 0 cxt 0 m II m 111 0 Z - Q 2, r Q (I) Z 00 "i 0 z '. rntlph•m nm^wmunnHm� 1, ;OL'9 ,��tdXJ =AS 0171330 :Ai NAM .� MASS 31V0 CIS 3 j 0 -4 661 1 -MO 19) MBOE, 01HO `311IA831S3M 8 l 3i�fS S dO SSOdO ONIbdVH3 lL l all •SINtillfSNOO N 8 H L pond ivowneomm 5 3 N C2i, �!y '•df NO 111MRIO3N l 1VN10 111 OOV I103 VOX O71 133HS 33S ' a311dd1S 10I11NO3 32m1vx3€I31 A8 031.33a10 SV 3x I■ IMAM) 11V1SN I ca 0013Vd1NO3 1V3 I NVH33N1 ' x3RlO3SNva1 VA O* AOZ I /A$Z 11VISN I ONV Jim 3VAN H U N M10N31d N I 3181 SS374V N O 1 11001 x08-r 003 S133HS 11(31 x13313 01 a333a "21013V IN00 1V71NVH33M A8 0311ViSN1 ONV 39V)OVd IDHLNO3 H114 341OS1 A8 03HSINH0J x31a035NVal ONv 3"100011 IO INO3 NOIlvmuO3NI 1VN011I00v xOA 1 13345 01 a3d3x NVd M013x3A0 AavON 0035 341 NI 11(3 I NVH331 311 AS O311VISN 1 ONV 3.051 AS 0345 i Nwl3 431115 M013a3A0 31VSN3ONO3 11VISN I `NOI 1VIWg3N I 1VN011100V x03 I'031 13345 01 d33311 'X08 ONIXIA JO Mv3a1SNMOO 1V3INVH7311 3H1 A8 0311VISN 1 OMI 38051 A8 03151 Nafld VOSN3S a I V 03x 111 11013vMMOO 1V7 I NVH73A A8 0311VLSN I OM► 341051 A8 0345 I NH0J 38 01 ' SxOSN3S d4V SSOIV1113V a3d1VG IN 10013N I ' S1N31OdNx3 l01e1NO3 Hl 1 M X06 ON I X 111 'x08 9N i x 111 311 O1N I 13J*1O3 ONV 3Z 1 S 11(13 SNO 1133a1O3 L i m n MOH3 0311V1SN 1 38 111(45 x10M1300 " 1 I Nfl 1V 5N0113311103 13110 3181 X313 Hl I M ON I N3d0 1N31d 11103 JO 3Z 1 S 11113 30VM1 39 1 nHV 01 SN01133NIN103 17110 sly 301 SlflO ONV A1dd05 ' NRlfl131! MO 11V11x03N1 1VNO 11 10OV dO3 1'031 13315 01 1134311 ' SS3331( 331 Aa3S SMO11V 1VH1 NOi1V3O1 V NI xOSN3S 11V1SN1 'a013Vx1NO3 1V3INVH3311 311 AS 0311VISN I ONV 340S1 AS 03HS I NIN13 dOSN3S sly 31aV1O5 I 0 ' SLN313a 1 nO3a 1VN0 I 1 I O0V x03 .9NIdId 1NVx3O11:133a. 'N01133S NOIIV3I3133dS 1V3INVH331N O1 x3333 ' SNO 1133NNOD lvN 13 3)11(11 ONV 11 Nn ON I SN30ND3 X0 031003 HIV O1 1103 x0 S.1 I Nn 9N 110NVH HIV 341 r1Oa3 S3N 11 1NVt13O I dd 321 11134 11V1SN I ONV HS I NRlt13 11VHS dO13Va1NO0 1V3I NVH331 3111 "A131VI03M1 a3Dywn 133r0ad 7 311 13V1NO3 '031IV190 38 LON NV1 V3dV 331J3 SIHi. 31 "1N31d1 1103 30 33NVN31N I VM1 ONV NO 11VT1V1SN I x03 M011V 01 03111 V1N I VM1 Si 1N3Ad I flO3 0N0OHY SNO 117331 0 11v NI A11V1NDZ I a0H 1333 -Z ONV A11V311a3A 1333 -f 3O V3aV 3303 03130a1S80N 0 MrNh11 N I VI V 11(41 3H0SN3 01 3191 SN 0dS3a 38 11VHS 0013Va1NO3 Sim " 9N 1 1133 3A08V 031V001 1N3Md1003 01 SS330V x03 0350 39 01 33IA30 HIV ' NID 11V1R103N 1 1VNO I L I O0V x03 1'031 133HS O1 d333a "SS333V 331Aa3S SMD11V LvH1 N0 1 11(301 V NI 17n0 HIV Nxnl3x NI dOSN3S 11VISN I' d013Vt11NO3 1V3 I NVH331 311 AS 0311VJSN I GA' 31051 A9 0315 I Nxfl3 x0SN3S Z03 'N0I1V11d03N1 1VN011100V x03 1'031 133HS ONV 01 x3A3x 'SS333V 331Aa3S SM011V 1vH1 NO11V301 V NI 000H a1V 3OISlnO NI dOSN3S 11VLSNI 1013Vx1NO3 1V71NVH331 341 A8 0311VISN I ONV 311051 AS 03HS I NR111.1 dOSN3S a I V 301500 ' NO 11V301 318155333v NV NI 39 15(11 x0133130 3m3115 'H0133130 3H1 1V ONV OdVO6 10a1NO3 3an1Va3dI%31 3H1 01 SNOT 133NNO3 ON I x I M 1VN11 ! 111( 3)(1(11 01 S 1 131► ON! 1 a 1 M •0x1NO3 030131 HS 031Va 10N31d 11V1SN 1 11VHS x013Va1NO3 11(3 I NVH33r ' IJ013Vx1NO3 1V3 I NV1331 AS 0311V1SN I (91111 800N3A 10a1NO3 DIIOS1 AS 03HS I NRN13 1300 ally x03 x0133130 3)IamS 'SN0113f111SNI NOI1V11VISNI x3Hlxn4 x03 a3OVNVMI 133r0ad S.3 13V1NO3 A131V 10311111 ' 11011V301 51 H1 Ni O3NIV190 38 IONNV3 V3aV 33x3 3i '1VA0xddV S.x3OYNVM1 133rOdd 390S1 Oa 1331805 SV3HV 35341 01 SS333V 301 AOad Ol ONV V3aV 51W. NI 11 Nn 3H1 JO 149 13H 1'113 3H1 S33NVxV313 331Aa3S NIV1NIVMI Cu A111I8ISNOdS3d S.a013Vx1NO3 1V31NVH331 311 SI 11 ' 33NVN31N I VII 1N311d 1003 x03 S33NVxv313 03013N1033a S. a3afl13V3(ton S1N3S36d3a LN3MId 1 003 3VAH 0NN1011V 3N I 1 03HSVO 'S3903 1300 01 03M3a3S a0 0313AIa 'N33a3S0a18 HI IM 1300 !0 ON3 N3d0 a3A03 ' 11x031V1d 3A09V .Z t an 1300 " VJ 91 81115 ' P' 031V1d 3A0811 1lYM 01 14011 do ONV 33VdS 1S I Or NJfl0ll ON 1 1133 x3101 NI 331A30 M10a3 13(10 11113113 3HS Nnx (' ! ' r V .0-.9 ' x0addV ) ' 1R10l1V1d N10139 9N 1 1133 11VMil 410 a3M01 NI 0311001 33 I A30 HIV ' SN011Va01 VOA SNV1d 01 a333a ' 033 1 00311 SV S31dOSS333V ONV dV3 MOON '13n0 LSnVHX3 11VISNI ONV HSINana Ol a013Va1N00 WON 131101 3A08V NV.J 1SnVHx 3 131101 11VLSN I "0310N SV 3dV NOIIVA313 ONV 3ZIS '3dA1 1NI1113d 01 ON1did JNI1S1X3 "0310N 51( 3d! NO I LVA313 ONV 3Z 1 S ' 3dAL " N 11113x Ol xaO1Ml3(0 ON I IS I x3 'N01LV11VLSNI 01 WPM a3OVNVM 133rOdd S.3110S1 Hl 1M dOSN3S JO MO 11N30, 171(X3 A.11 0A 10001! O3HS I N I d 34&081( .910 1V d013Va1N07 1V3I NVH3311 3H1 AB 0311VJSN I ONV 39051 4&8 031S I N anJ aOSN3S 3dfl1Va34M31 1001 4B• 0 c> O I! 0 0 1 a 0 0 a • 0 0 v ry O a Oct IRE a 0 - O ---� 11110110 13 1V N1100 IMO J004 9 , 44 (40 04 V' a a dill 03AOr13a 39 NIV113x Ol 9N11SIX3 031V3013x 11000 ifl3x30Nfl NO11331003 3O 111IOd 00133130 3x0MLS '0111 13(10 IVLSO11a3H1 dOSN3S 3a(11Vx3d1131 MOO • 13110 ONnos do - L3n0 minim 13110 3191X314 °Z • a 3�i+loi 0011 - 113d11V0 Q3 O o9v - a3d11V0 Iwamoto 311V1101nV OSl3 - x32111(0 NOILVN18111103 03 - 1113dm0 3x1! 0 a 0.01 .0I l S3•1YS X74(0) -- (3) rzga. D .Z1x2I (a) 0 0 0 0 0.01 U 0 •.01 ciet T-E 09£ T-g Zee 0 0 0 0 !I 0 0 53NVA 9N$Ndnl /M 10813 MOO - 1(10 "HX3 dO 141(113t1 do - lan0 ' HX3 a0 Nxn13d MOO - 13(10 AlddflS do - 13(10 Alddr1S NOILISNVai 13(10 31a1N33NO3 NOILISNVdI 13110 31111113333 a3d11V0 33NV1V8 13NVd/a000 SS303v 3111aD Nllf13a 3113118 910Z1V0133S/M 113501310 4&122(15 113S114.100 A1ddnS ► =� 9N11113 M NIdS I 30V18 0350dd0 SX11V113d • 0 • 0 • 0 • • 0 • • • • • 1'£011 13345 NO 11V130 335 'AVM - NVHL x3H1O M013dIV d03 1018 1VNOU33a10 801 301110x2 :310N NI -AV1 0 1008 031V1nSNI 6£ -d1( H11M 1130x08 ONV 3NVx3 XX -YZ I'£OMI 13345 NO 111(130 33S 9N11133 11VMAVO dO3 3MVx3 1 f 13004 Snlll H1110 3014&0x2 'NI -AVl 0 031N11011 33Vix05 C) 311115 a30d00 • 33-OZOS # 130011 ddO 'dOIVlnO3d S,ON=OA 1O211NO3 311(110A /M a3d1VVO 343 d033 03 043 NDISna 1NVaavno S31a3S x 13001 3NAO0s00 sa3lma '(H51N13 131VN3 HIM TIVM dO 31111133 H31VN1 01 8 VO V 1NIVd 01314 01 - 3 . 0) on) '3111* x31100 - at snlu use dX3 'dY3N11) '311141 OdY ONV1S - 9L# snit' 0 0 a HSINI4 3111a3 -9 1131S10321-a x3503310 -0 1131131 0NO33S 1snVHx3 -3 minim-a AlddnS -5 4131131 15x13 A 3)I 1081111S :0N3'031 Mike MO All £ worms r9M.>wes so soma 311t V ware" al Mad 111118181D of~113 MN as a:1lr►3Nrrs 31 MN 11111 1rp01.]A4 3a alimeriM 3 asMMw NOtt311.21100 31 .!a 110111431111 311 at 11 OUS 311 A713tviO311111 ,5114 LWOW Sea JO 11011v se. 311 L311lr AVM 91011003 Irat SMag a amid Gnu 3a r Sime_ 11, & IM31► alt S1 a0L3111•1oo WIN 331x1 Sr -_ slO1tw313 x,]119 alit ' i1r 111311160103 w° TM .S lamp S1 (same /swam 3L31CMD0 is mots) 11311131 11111M'IL3(3LS 15.3.011 !0 waular all gab MGM • 110rad1► 10 31011v 31039 JD 101/100 at a001J 13D t • 13131 110 0311,3019 MOILS 319111(4.1(110 Swam - S9 •_Va0 1var g '! N (AMMO NI 0101011r1 A31105 01,4 110 03 VO SHO[1 VA313 1YIA13fl8iS 1 -n • S310N 1V3INVH3311 i • iliblowitmemrammg. d :: \/ I � W A 0 massissianis ✓ - 0 0 Iv 0 0 0 0 • • • • 0 • • • 0.01 0 (del n --°.-8 0 1.01 0 (dill Y J� • { A 0_4 _0 • • r�01 0 • • • • • • • • • • dS 0 0 } (du nag t) u 0 dS 0.01 dS 0 0 0.01 Z- imi � 0 0 dS (du ( du. 831VS • 0 0 cis • • • • 0 dS • r 0 0 0 ... wow a 0 S108101l1S aNV (IN3031 Q NIP c c O o • l 31�uS a3'lddfl5 a , • t • • • • 0 • • • • 0 .z 1 1 0 • HSINU '110111 1VIa31VS Drama' 3ZIs 4 X3 31 0 0 0 o 0 • • • • • 0 INM -■• 0 i • 0 0 0 0 0 0 0 • 0.01 { 0 0 i � a c 0 0 1 II a 10 O H I Il • 0 0 0 0 0 i _ w ! 0 0 f.r O 0 1! 111111m.U• 110.11 ■ 0 �Ir Aft 3 0 0 0 0 0 0 0 0 0 0 El ECM ._ -- - - - - ds a 0 .01 OPC Z=� 0 l dS 0 O T 0 ( J U xiS . Zx.►Z TRE IF 0 V 0 RICE 0 INN 1 CCII dS 17775 I 1 1r • • • • • • • 1331s taw° • • • • IN -SSC -0v3 1H-CSC C-Od 11-CSC Z -ON Sal-00E S-aS iNnO -as ono t -as Maim 130011 10811AS 3 '30 01 11311AVd 1,111J 01 M03031141 38 TTVHS 380S1 AO 1110d311 51141 JO 3311V1d333Y . 101/310103 NOdn 113000 011)1/10" 113d01141 3VOS.13 01 SVOMISIWCN 03111O0311 ANY 3)IVN (S)131SAS 1131WA/VIV JO 0113W/110 3111 P1110J113.1 11VHS ANVd1103 51141 VON 00 311VY JO 11381311 `LN30143d3am Nv JO 33IA83S 3111 30V0113 TWIG 1101311111403 1V1131130 L ATM TIVHS VOLOVVINO0 311 e )1/1104 NU JO P10113141103 NOM 1 110110311K1 110.1 1130VNYM 1331'011d 3,061 13 A13111031111 `318v1.1333Y ION SI POMO 1'311113313 11110*1300 1131110 'WWI VMS NO/Th 01 AV,331110 SN311 HMS 38 'TIM '313 8 5331A30 ONIN31SYJ IdVillS 1300 6 SM* MOWN '4 3003 KIM satin 38 TOMS monona Nan1311 Alddl1S *3 110131 NI .0-,t 0333X3 01 /ON 13na art rsixru (1st is) own - rn )1111111.1 1113013A 1 woo NOW SVIONVV8 '031VNOIS30 3113110 '0 113188V8 80dVA 'vim .1 JO WWI V mia maims 38 Ow 30m0 UmadOaddv MI JO MS 30VVO 1V1311310103 JO ON, MN 311 INNS 1VIN31VII 'S1131131 )13V111 110114 .1P NI 03113131S 38 Tim ONV NOILYNDIS30 38 TIM 1N3P1d1O03 011101110103 NV ONV 0011Y11N3A ONILY3H 31V 't '0'003 `INS NO 31(103140S • • !� • • Sr Sr c4 /91/01 CA N 0 C)) Z .. 0,D 0 -u m CI - CI pi 0 0 w z V Z 1y 00 r*� > 0 '1M I re X - 0 213 0 : F 0 .. ✓ i A Z 0 w 00 CA CA N C44 N > 014 Kind 1rOM1rNO311 cn •V loons mama 0 0 • ? r eci,) w K 5 3jm (—IZ �. m CJ CD iv 0, -I R- m `�' o 0Z g p z - , �Z 5 5 — I g) W C Z cv 0 0 r,0, 0 —I' 0 Z Q_ Ci) wurnunnrw +marwnnmmw:nnrrmm�anww� t f S rr rt�n� 411 anniCI :AS NEMO :All aN01530 MASSA 31M0 �r�s 7�r �► snifter • arras COMM :SNOISIA.321 CA Cli //� - W V -1 =n » m , �Z UMW mom 0,1 r rn 30 0 c. 6 Z88(,19) 190£, OIHO '311IA0131S3M 81 3llns S 0,0 SsoaO ONIadYH3 1 L 1 011 'SLNY11 f SNO3 )1 8 H • Mid WOINVW33N1 I- it • Irl liv ANI]A MMIIM- ' r' AN= = �� - WA 40 "iat. LUG 3 . au I woo aillw a w adi MK SAMS on 3u*3 A 31 11 61 11* - 13311111 M1! 51M•b V 1e UK 9041311411003 allo r•ry 111 1S110II 4119, w! .3091e LAIIIIMOMI «r SOO illOr 101 bid a . WAN t • 17DA MC *1* wd 'dMIR3 'd'M t "d'S' 3 .0" 1 • "It's 1103 ONO — &air - 0M 131 ]3 II 1 oarali S.3 * awl Oil S3128 sal Jw is0d311 "SeStliN311 C1001 1191n1 Sl1ta• Enna 'GUM S41 WU, 111 3319r611311 •M' w310 - 1041m301 1711x3 Ai I * i milli ' 0,391 a• Oil wi !3113( abk111d1 40011 2111S 1 x0, 0 0 • • • • 0 0 I 1 1 r i PI 'OM 01 MUM COWS St► xs0■0110 0111► ID11r>Dl i31,41 Ai s3A 07314 'aura JOIN 0w N331106 Or 10 111,131 1111893iN 1 MINI S.31 105$333v soma 1 Si x3 'MOO 311111SS3md .1 0 IM111I ray • wi3 000! '039n311 36 Ol MYICIA - OM mom !1003 cam =a om 3]1I/1M 1 sal iS i x3 - 1111♦ MI31 M31s3 1SM I V',yV 0111.0035v6 IV M31V31 DIM 0315 I 1 - 1 n 3 1i1AI5 11 1M1, 'J.99 111 136 1VIS0111311 0311M1a1 rycons 711M.931M 1 Hun 11S Imaii 0301I101 rycia RS 'Di OM ' - Md I " A OZ 1 • • OSL MC ISrZ302•1 7300,1 Oxen 21311131 01lIIi0935* 31&13313 S31 aOSS333v ONV 0113 JOON I c ' + ' : t : . " o i l . 3 . 3 A8 1011 MS 11011 MUM 037C7D11131N 1 011~ 1-AOL I '8010N dill Z 1/ I - d'S .s • I1L43 O01 M14/ 1300w 14331NV! vein NUJ 1StMM X3 131101 31111 -N1 NO 1111x81 A N I adS GlIM wawa 0, NO 11x1 I S Irc 3 3N11-NI '3131d1 SI I NV313 311OLS 1vN I i V314v N I VOV 3010 GIV 33 1V8 HIV 01 201 ad 1StW 5!311 14 33V d31 01 i3v 111 3 ' Sa31114 a 1 V OavONV1S S13S 330,11 .. IC ■ . . :II'.". NONUO45Nra1 10tl1NO3 'NOI 1MIVOII I 1MIO 11100V VOA 1 133 HS 33S ' 1N I Od 13S 3101131 ' dOSN3S 3DvdS 310•30 '1ONDIO3 dD1S/L?JVIS NV4 '10111103 a31r314 13(10 ' a0SN3S sly 1311 I ' aD1Vn10V ' 31f10a1 1011x100 1131SAS 10V1N00 NO31113 : • is• - 1 - '"' : r - I I. • r T 111 00 ' ' Hd t '110A 90Z ' dH Z/ t ZH 09 - Hid f ' il0A VOZ 'MCI S _ d'S' 3 S'0 • 1140 OOS NO I 1 I SOd 1ri11 N I MI 1140 00, = NO 1 S30 MJ3 099 .il 3ZIS 13111 'SI 3ZIS LINn :1101011 Nv4 : V31V3H 71!17373 = Nv4 :HIV A2M11 ad 3dSCO 730011 Viol 1 VN £O-01 3JV)17Vd Limn 1vN I I'R131 a 1 V 319V I avA 03a3M0d Nv3 ' ND 1 1x11!10411 1VN0111 OOV VOA Sl 1x130 ON 1 d I d 1NVa39 I 4321 01 d343a - SiNN13a 1 n03a M131SAS &M BA a3A O1 yoinerdiSI0 1131SAS N011Va39Ia43a ONIN0I10Nni 0Nv 3131JID3 V 11VISN I O1 030,1(133! SA311 llV 0NV S3A1VA NOISNVdx3 Imam. 'S3A1VA OION310S 110A $Z 'S3SSV15 U'01 S ' Sa3 I a0 2131114 ' SiaOd SN I OaVHJ ' S3A1VA J40-in HS S31210SS333V 911111 NOI1Va391a33d 11Nn 11110ddn5 01 1vl03 0,0 Sea13 .31Vd. HMON31 11nJ = S31 a0SS337V 03111/151 I ONV 43NS I NHnJ ND13VJIN00 - 03H1* OIIV 0311VLSN I Ala3dO8d 1OR11NO3 1N3 I Ev'1v Nr11 ( —) '03a1M ONV O311VJSN 1 A1a3dO 1d Aa05S333V 1Oa1NO3 1SviS a31N 1 M ( —) 'S33113Vad 03014391033s aid O311ViSN I SdOLV3 I ON I n1S I ON a I nD l l ONV Sa3 1 710 x31114 (-) ' (318vv I lddv 3a319) 10a1NO3 A112VdV3 VOA O311VISN I 3A1VA 010N310S 3N11 0111011 (`) '10a1NO3 1NVa39Idi3a d0a0 010N310S VOA O311ViSN 13A1VA 010N310S 3N 11 arm, '3N11 1V1NOZ I dOH NO )0013.0 i iv dO 31411 towns 4O a3S I a 1v3 11a3A NO 0311r1SN I A1a3dO2ld 8x18 9N I SN3S Axl ("-) '0311V1SNI ONV 03ZIS A1133aa00 S.AX. ' 031V VISN I A1a3dOad 3N I 1 NO 113nS ( —) ( —) - else a0SN3S AXl JO Mv3ViSdn 0311VJSNI 5.0913 .06 010.L 4O "MINIM V Hi 1M ' S33 110Vad 030N3 11 330, HUM 33NV0a007V NI 3100 1103 HO1Va0dVA3 311 IV ONIdId 3111 NO 113fS - Nanl3a 110 VOA 031431 I d A1a3d02k1 S3111 iNVa391 a43a Sa3'3NVH 1111/1 031aOddrlS Ala3dOad S3N I 1 iNVa351 a43a '1.111 01(1011 JO 1H91311 ONV SON 111 14 JO Worm ' 33NVLS I O VOA a3Z 1 S A1a3d0ad S3N I 1 iNVa3O I ai3a ( ) i'0 '00501 N01133S NO11V314133dS KIM 33NV011033v NI a0133dSNI x0NN31 11301 A8 031311403 38 01 IS 1 1)0310 NO I L33dSN I NO 11V1IVLSN I N131SAS l 11dS ( —) 741051 AO 01Vd3ad NO1133d5NE 031VNIOa003 HO17Va1NO3 SN01103NNO3 10a1NO3 3aniYa3Gr131 ONV 11310,10313 11V ON I Oni0N 1 ' SN011VON3nn003a S. a3af113V4nNVMl aid S31 a0SS333V 031S I 1 311 11V1SN I A13131d03 01 318 I SNOdS3a SI a013Va1N00 30Vx0Vd ON I d 1 d annd 1x31 S3IVOSS333V 0311VLSNI dO17VaiNO3 ONV 0301A0ad MOST ' 8l SOP :11.1513M ON 11ra3d0 10f -A90Z : 39x1l0A 10411 SNO1 S'L :5101 NI 3ZIS A- 06-&dH :ON 1300N i I Nn 68-01 30VX3Vd JIM DNISN3ON00 XONN31 ' NO I iVIR104N I 1.00V dO4 von £011 133HS NO 1nO1N 1 ldd IN3rid I n03 01 a343a ' IOW NO 0311VJSN 1 11 Nn drl<ld 1r3H 031000 a I V SdOiVlOSI NOILVa8IA ONIadS ONV amens NO I iYN 1 81103 3N11-NI H1 IM 3an10na1S Nga4 030N3GSnS SI 1INn'AIMMOSVH NOISN3dSAS ONV SdOIVlOSI NOIlraelA ' 3131dm03 S I JN I NV3i3 3dOlS 1VN 14 a314V NIVOV 3010 ONV 33NV1V8 dIV 01 dOlad 'Sir Sd3illi 33V1d3a Ol a010Va1N00 ' Sa31114 HIV OdVONYLS S13S 330,11 53 I a055333V 031 1/1151 I ONV - 0315 I Nan4 a013V211NOa ' SN011r0N3MM033a S. d3an13YJflNMU aid S3 I dOSS333V 031S I 1 311 11V1SN I A13131c4103 01 3181 SNOdS3a S I dO10rd1N00 3A1VA 010N310S 39V)OYd ONIdId Grind 1V3H S13)13ra8 NOISN3dSnS OV3Ha3A0 ' NO 11VNRp4N 1 1VN011 1 0011 dOi 1'031 13315 33S 14311MS M014a3A0 31VSN3ON00 'dOSN3S INIOd 13S 3101138 11OSN3S 33VdS 310M13a '10a1NO3 dOlS/laYLS NV4 HIV 43113d ' 10a1N00 dOlS/ldVIS NV4 (A1N0 L -lila s aOSN3S 301x010 NO8dY3 'Od1NO3 a3dVIV0 x00 Nunn A1NO L-nla dOSN3S dIV 301Sin0 'dOSN3S alr 3tdVH3SIO '3'1n00n 10a1NO3 4131SAS lOa1NO3 NO3 I3 (SL31NI VV3a 1 d01) XOe ONIXINI :t 0,4 S'1 - 3AIdO OSVONV1S NOI I33S !31114 1x14 .Z 1 53i/105533W 0311 VLSN I - Aa017V I NI43 OCS :HIV 3OIS1n0 'NI“ 'd'S'3 .0' 1/1140 000e :aIV A1ddl1S • 91 LSC :114013M ON 11Vd3d0 and 1V3H :1r3H 4O 3dAl 41 0 - A9OL :3019110A tUNA A-S6 -L 1 180 :ON 130011 I'm 68-01 3D10Vd 11 Nn ON 1 101x14 dIV XONN31 ' NO 11VMVO N I 1.001 VOA It 011 13315 NO 1f101N I ad iN3Ad 1 n03 01 71343a '1103 11011 1x31 N131SAS -1 11dS HUM M 1 I Nn '0141 1003 ON 11ONVH dIV ,0 Allta MIL ICY AIL d Q El COOLING AT • Jun • 1500 HEATING AT • Winter Design COOLING OA 08/RH..: 83.0 F / 38 % HEATING OA 08...: 21.0 F ZONE LOADS Details 4 COOLING Sensible Latent (BTU/hr) (BTU/hr) t HEATING Sensible (8TU/hr) Solar Loads 0 sqft ACTUAL OUTSIDE AIR REMARKS t 1 - Wail Transmission 496 sqft 165 W. SALES 1719 Roof Transmission 5597 sqft . AHU-1 530 27425 Gloss Transmission 0 stilt 1279 0.15 0 Skylight Transmission 0 stilt 400 IR TOTAL , 0 Door 1 r onsmi ss ion 0 waft 1.060 - 0 Floor Transmission 5597 sqft --- --- 914 P a r t i t i o n s 0 sqft MO It -- 0 Ceiling -- -i - 0 sqf t 0 --- --- 0 Overhead Lighting 3273 W - 1 Task Lighting 15277 W - 3EINSIONIMIC - Electric Equipment 2615 W 3n - - - People 64 people 40 II 411 It " il infiltration 1 ----- MisceIIonou I 0 EMI is - - Safety Foetal, 10/ 10/ 10 Ig ar•r.r. 3006 »Total Zone Loods (1) I I 88875 17459 I 33065 Zone Conditioning (2) MISC. BTU FOR COMPUTER LOAD EST. 92414 17459 Plenuellfell Lood 75 - PlenumRoof Lood 27927 - Plenum Lighting Lood 3350 - Return Fen Loed ■ 0 - 0 Ventilation Lood 6630 -1689 Supply Fon Load 7633 Spoce Fon Coil Fans 0 - Duct Heat Goin/Loss 0 - >>Tot•I Systems Loads I I 13E1029 15770 I 99699 Central Cooling Coil 138030 15763 •0000 ! ! 0, Central Heating Coil 0 Precool Coil 0 0 Preheat Coil 0 Central Reheat Coil 0 - Humiditicetion Load 0 0 Tsnminoi Roulet Coils 0 Spoce/Skin Heat Coils 0 - »Total Conditiowing I I 138030 15783 I - 99699 . OUTSIDE AIR REQUIREMENTS EOUPMIDAT NAME ROOM PURPOSE FLOOR AREA SO. FT. ASHRAE 62-1989 OUTSIDE AIR REQUIREMENTS SALES SYSTEM NUMBER ACTUAL OUTSIDE AIR REMARKS CFM PER sa FT CFM REM CFM PER UNIT 165 W. SALES 4323 an 865 . AHU-1 530 275 IL 775 It NON SALES 1279 0.15 192 AHU-2 530 400 IR TOTAL , --- 1.120 TOTAL 1.060 - , MISC. ELEC. WATTS FOR COMPUTER LOAD EST. EOUPMIDAT NAME NIX. ELEC. KO H.VA.C. LOAD WATTS ROOMS SALES \ NON SALES CITY, WATTS OTT. WATTS AEI SOUND SYSIEM 165 W. • 165 W. - - 1 N 165 CASH NEMER 275 IL 775 It 4 1100 - --- PC 0911PU1DIVPRINIER I 4110 It 400 IR --- --- 1 409 roams 120 111. 120 W --- 390 --- --- 7CP PANEL 230 IL MO It -- 1 --- MOIL 3W It - 1 - 3EINSIONIMIC NU 3110 It 1 3n - - lox sister 40 II 411 It ----- 1 ----- 1111L BrOMMER 0 EMI is - . ....- . ar•r.r. ligeat WC 113101 I 4 1f4O0 , MISC. BTU FOR COMPUTER LOAD EST. • STORM COLLAR FLASHING BY G.C. EXH. DUCT FROM RESTROOM EXHAUST DUCT THROUGH ROOF DETAIL FROM CEIUNG EXHAUST MILL W/HARD DUCT CONNECTION COUNG JOIST (TW) FACTORY MOUNTING BRACKET SECURED TO CEIUNG JOIST UP THRU ROOF OR LA_ EXAUST MAIN TOILET EXHAUST IN-LINE FAN • , hi I N.T.S. XDT • I N.T.S. J K TYP. DUCT TRANSITION DETAILS ILT.S. 00011111LTIRAN E OUTSIDE AIR CALCULATIONS NO1E ROUGH-IN OPENING NOMINAL 20"st 20" a 20 1,/2"s 20 1/2" NOMINAL 24 2e 24 1/2 24 1/2 DRYWALL CEILING FRAME MOUNTING DETAIL N.T.S. N.T.S. 000110311:111E CEILING DIFFUSER MOUNTING DETAIL II N.T.S. I F DAMPER HANDLE TO BE INSTALLED MAXIMUM OF .3 ABOVE CEILING. SUPPLY /WR DIFFUSER (LAY-IN FRAME) ROUND DUCT 11111111111111111111 18" LONG ORANGE MARKER INSULATED Flaw CONNECD3N (MK 3 FT., MAL 4 FT.) TO IDENTIFY LOCATION TAPE ATTACHED TO DAMPER - FIRE DAMPER WHERE - INDICATED ON PLANS. / 1111111111■ irrus MODEL * Dr DIRECTIONAL BLOW PLATE CUPPED ON DIFFUSER RODS SEE NOW BELOIT. PROVIDE VOLUME DAMPER WTH LOCKING CUADRANT. PROMO( WITH r EXTENDED SHAFT AND HANDLE (SEE AR DEVICE SCHEDULE) SPIT. INTL EU3011 REQUIRED SECURELY TAPE VINYL FLEX DUCT TO 94T. UTI. W/ I. OF (2) CONTINUOUS WRAPS OF DUCT TAPE STRAP CLAMP OVER FLEX DUCT INSULATION a VIM TO 947. MTL TAPE INSULATION TO DUCT TO FORA A GOOD SEAL its LONG 941. MIL SECTION SECURED TO DIFFUSER COLLAR W/ MIK (3) 91T. MTL SCREWS. DUCT TAPE AND INAS11C. TRANSITION FROM DUCT SIZE TO COMM NECK SIZE AS NECESSARY 'THERMAL INSULATING BLANKET REQUIRED FOR ARE RATED CEILINGS ONLY CEILING IIKKINTIMG FRAME FOR op. APPUCATION TIT. MODEL MIL SEE OCTM. 3 1116 WET NOM #4.1 DIFFUSERS ARE 4-MAY BLOW MESS N OTED °THEME- PROVIDE OPTIONAL DiRECTIONAL BLOIL 17US MODEL 06 TO CONVERT DIFFUSER FROM STANDARD 4-WAY 70 1-WAY. 2-IWAY OR 3-111117 BLOW AS DESICTIMED ON PLANS BY SHADED AREA. G LENNOX PRODUCT SUBMITTAL THE LIMITED - SOUTH CENTER LENNOX PRODUCT SUBMITTAL OCTOBER 16. 2003 PROJECT INFORMATION. THE LIMITED - SOUTH CENTER SEATTLE. WA UNIT ID: AHU-1 & 2 / HP-1 is 2 CONDENSING UNIT NAME HP29-090-3Y HEATPUMP/7.5TON/230-3 COIL NAME CBH17 -95V-3 FAN-COIL/7.510N SOUND RATING NUMBER OF OUTSIDE UNIT (08) 92.0 HEATING HEAT SOURCE COP 47 DEGREES CAPACITY 47 DEGREES TOTAL. UNIT POWER • 47 DEGREES COP 17 DEGREES CAPACITY 17 DEGREES TOTAL UNIT POWER • 17 DEGREES HEAT PUMP HEATING DESIGN TEMP. HEAT PUMP OUTPUT AT ABOVE TEMP. COOLING ARI NET COOLING ARI TOTAL UNIT WATTS ARI EER (BTUH/WATT) ENTERING EVAPORATOR DRY BULB TEMPERATURE ENTERING EVAPORATOR WET BULB TEMPERATURE OUTSICC AIR DRY BULB TEMPERATURE GROSS COOLING CAPACITY SENSIBLE COOLING CAPACITY LEAVING EVAPORATOR DRY BULB TEMPERATURE LEAVING EVAPORATOR VET BULB TEMPERATURE REFRIGERANT TYPE CONDENSING UNIT LIQUID LINE SIZE CONDENSING UNIT SUCTION LINE SIZE COIL CONDENSATE DRAIN SIZE COIL LIQUID LINE SIZE COIL SUCTION LINE SIZE BLOWER PERFORMANCE BLOWER AIR VOLUME EXTERNAL STATIC PRESSURE REQUIRED BLOWER MOTOR INCLUDING WET COIL NOMINAL BLOWER MOTOR BLOWER TYPE OCTOBER 16. 2003 SEATTLE. WA HP 3.2 85.000 7.790 2.0 47.000 6.890 21.0 (DEC F 52.111 (BTUH) 90.000 (BTUH) 8.910 10.1 63.7 DEG F 93.0 DEC F 78.1 iDEG F 91.231 (BTUH 76.306 (BTUH 54.6 (DEC F 53.5 (DEG F R22 (2) • 1/4 IN. 1 3/8 IN. 1 3/8 IN. 5/8 IN. 3/8 IN. 3.000 (CFM 1.00 (IN. W.C. 1.30 (HP 1.5 (HP BELT ELECTRICAL CONDENSING UNIT POWER SUPPLY 208/230 V 3 PHASE CONDENSING UNIT OPERATING RANGE + OR - 1011 COMPRESSOR 1 RLA 28.8 CONDENSING UNIT MINIMUM CIRCUIT AMPAC1TY 40.0 CONDENSING UNIT RECOMMENDED MAXIMUM FUSE (AMPS) 60.0 BLOWER COIL POWER SUPPLY 230 V 3 PHASE BLOWER COIL OPERATING RANGE + OR - 10* BLOWER MOTOR FULL LOAD AMPS 5.6 A/C UNIT PERFORMANCE MISC. illfAC CALCULATIONS N.T.S. • B 1 DESIGN PARAMETERS MO NMMINMOID. 1 ■..1110■1•••■•■■•1.10, City Name • Location • Latitude Longitude Elevation Summer Design Dry-Bulb Summer Coincident Wet-Bulb Summer Daily Range Winter Design Dry-bulb Atmospheric Clearness Number Average Ground Reflectance Soil Conductivity Local Time Zone (GMT +/- N hours).: Current data is HVAC LOAD CALCULAT1ON$ AIR SYSTEM SIZING SUMMARY Air System.: SOUTHCENTER 10.-13-03 Weather • Seattle-Toccoa. Washington HAP v3.20 Prepared By: HEIK CONSULTANTS Page 1 AIR SYSTEM INFORMATION System Type • Number of Zones • SIZING CALCULATION INFORMATION Zone and Space Sizing Method: Zone CFM: Sum of Space Airflows Space CFM: Peak Space Load CENTRAL COOLING COIL SIZING DATA Total coil load (Tons) • Sensible coil load (Tons).: Coil CFM at Jun 1500 Max possible CFM Design supply temp (F)....: sqft/Ton • 436 7 BTU/hr/sqft • 27.5 Water gpm • low rise • 30.78 ar.M.M•wmwmmlbwIlwa SUPPLY FAN SIZING DATA IIIINIMMININ■IMIMMIMM O M MI III MM IN N II MMINM E RINI.1.11114101••••••••11i Actual max CFM Standard CFM Actual max CFM/sqft TABLE 2. ZONE SIZING DATA Zone Name Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 CAV/RH) 6 Zone and Space Sizing Method: Zone CFM: Sum of Space Airflows Space CFM: Peak Spoce Load 12.8 11.5 5774 5774 57.0 TABLE 1. SIZING CALCULATION INFORMATION Cooling Sensible (MBH) 22.2 31.2 21.2 4.4 11.3 2.1 MT Seattle-Tocamo Washington 47.5 degrees 122.3 degrees 386.0 ft 84.0 F 65.0 F 22.0 F 21.0 F 1.05 0.20 0.800 BTU/hr/ft/F 8.0 hours Carrier Defaults Floor Area 5597 sqft Colculotion Months: JFMAMJJASOND Sizing Data • Calculated Load occurs at • Jun 1500 OA DB/RH (F/%) • 83.0/ 38.0 Entering Db/Wb • 78.2/ 63.8 F Leaving Db/Wb • 55.8/ 54.7 F Coil ADP • 53.7 F B ypass factor • 0.083 Resulting RH - 57% Zone T -stet Check.: 6 of 6 OK 5774 Fon motor BHP • 3.00 5694 Fan motor kW 2.24 1.03 OUTDOOR VENTILATION AIR DATA Design airflow (CFM) 1060 16.56 CFM/sqft 0.19 CFM/person ZONE SIZING SUMMARY Air System.: SOUTHCENTER 10-13-03 Weather • Seattle-Tacomo. Washington HAP v3.20 Prepared By: HBK CONSULTANTS Page 1 Calculation Months: JFMAMIJJASOND Sizing Data • Calculated Air Heating Flow Design Lood (CFM) Mon Hour (MBH) 1387 Jun 1800 1951 Jun 1800 1325 Jun 1800 275 Jun 1700 705 Jun 1600 130 Jun 1800 Note: Zone loads calculated at occupied thermostat setpoint. 6.3 10.3 5.0 1.7 7.9 1.8 AIR SYSTEM DESIGN LOAD SUMMARY Air System.: SOUTHCENTER 10-13-03 Weather • Seattle-Tacoma. Washington HAP v3.20 Prepared By: HOW CONSULTANTS Page 1 of 1 1 Notes: 1 Zone loads celculeted et occ ed upi thermostat setpoint. 2 Zone conditioning based on beet •xtrection enelysis. 3 In the COOLIING coition. positive loads indicete boat "sins. while positive coil loss indicate system hoot rumwvol. (4) In tom HEATING column. positive ioeds indicate beet loos, while positive coil loses indicate • system beet edditiom. SIPANWE z 4 ";:ltrti: HVAC LOAD CALCULATIONS A H B K CONSULTANTS. LTD 171 CHARRING CROSS DR S SUITE 18 WESTERVILLE, OHIO 43081 (614)882-1199 111 V. .L ... • / I " " • ; 0 . v co co co EXPIRES wilimumw tunt, um :um: z 0 P: b' Z D I Z CI) 2 0 Z O c' Cl. Z W CC Eli O w t- 0 cc W • CD ILL:0 REVISIONS: mem ep 4 Lit. --e _ aliCIMOS NM IMMO ND VII !Mr DATE Mak MINDED IT: DRAWN IT: CHECKED IT: cv) (NI (v) vT. 0 0 CO 0 0 E 3 o_ 71 a) I- OMMINIMIC NUNIElt M ririE22%.1 .18s.iv.at U M03.1 0 11:s r- 0 0 4( ce le Id (,) < tai'■ 0. 0 < la 0 0 NJZ ic7k 0 r" Z 711 0 0 d 0 IaJ- - 9- ak. 0 t 11; z o. 0 VI 0 ka VI 0 10;16 C3 wovs MECHANICAL LOAD CALCS AND DETAILS • • Ob • • • 0 • 4 • • 4 • a• C w 41 3minimmenna--118— J i S f su 1 l a WW1; 11 Xi ti gel% I g Plgei R 9 w i I M 7 I • a i N • • a I • a I A i I a I X a I • a I A us M a I • a t I • V I - • • a I us • a I • V I us • I wh 4 t M a I • V I • i • a I • I • I All 7 M I 1' a w a I M I N A1� ;1 1 S L I ri; { + S ‘ 1 cz' S S S S I I 0 r • m a 0 cn m r a a tO r z 0 m a r F p c� z 0 co A'N=== -4 C ;a z z .; ,* C) z m rn r ‘i3 0 A N g 2 F w Awl i I A PROJECT INFORMATION: THE LIMITED SOUTHCENTER 633 SOUTHCENTER MALL SEATTLE, WA 98188 SCOPE: RELOCATION /DOWNSIZE PACKAGE: DESIGN TYPE: ALMOND GENERATION: LSD&C PROJECT #: 00043770 A/E PROJECT #: 0100688 032FA 03341/03132 'ROMIIIITION ON MSC; THESE DRAWINGS AND SPECIFICATIONS WERE PREPARED FOR USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH THEI ISSUE DATE. THEY ARE NOT INTENDED FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. REUSE OF THESE DRAWINGS AND SPECIFICATIONS, OR ANY REPRODUCTION THEREOF, ON ANOTHER PROJECT IS PROHINTED AND CONTRARY TO LAW UNLESS EXPRESSLY AUTHORIZED IN WRiTINO BY LIMITED `` STORE PLANNING, INC., 0 /B /A LIMITED STORE DESIGN AND CONSTRUCTION "UM"). THESE DRAWINGS AND S►ECIflCATION$ ARE THE PROPERTY OF UDC AND SHALL NOT BE DISPLAYED IN ANY MANNER OR USED ON ANY OTHER PROJECT EXCEPT BY WRITTEN AGREEMENT WITH LSOC. NO REPRODUCTION Of THESE DRAWINGS AND SPECIFICATIONS SHALL BE MADE WITHOUT THE WRITTEN AUTHORIZATION OF THE LSDC. ALL ORIGINALS OR REPRODUCTIONS Of THESE DRAWINGS AND sPECiWICATIONS MUST S E RETURNED TO UDC UPON COMPLETION Of THEM INTENDED USE, UNLESS OTHERWISE AGREED BY THE UDC. THESEIODRAW NGS[AND SPECIFICATIONS ARE COPYRIGHTED AND SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 or THE COPYRIGHT ACT, 17 U.S.C. AS AMENDED DECEMBER 1550; KNOWN AS THE ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1550. THE PROTECTION INCLUDES, WITHOUT LIMITATION. THE OVERALL FORM, ARRANGEMENT AND COMPOSITION OF SPACES, AND ELEMENTS Of THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE DRAWINGS AND sPtCIFICATIONS MAY RESULT IN CESSATION OF CONSTRUCTION, BUILDING SEIZURE, AND /OR MONETARY L.IANUTT. Limited brands LIMITED STORE PLANNING, INC, d /b /a STORE DESIGN & CONSTRUCTION Three Limited Parkway -Columbus, Ohio 43230 Telephone: 614.415.7000 . Fax: 614.415.7349 http://www.I_SDnO.LimitedBrands.com : 0 t4' 7 , �rial Iv uvi�I • 1- L4x4x3/8 <- - -- / ! t DIAG • .. ao "'' x DO OD '7-7- ' J A F -- Q w m I— in W� W - DO L OVIC1, DIAG - DIAG d TYP 7 -95V -3 t-_ 7 r h. DO co :::7:1 I ,c _ _, OD �SOD, ix � I --+ DO F<1, I ;...v iu DIAG co ,I, J • AIR HANDLING UNIT LENNOX MODEL #CBH1 WEIGHT = 357 lbs -- A 1/2"0 A36 ROD, TYP 1/2"0 A36 TYP 24' -0" AIR HANDLING UNIT LENNOX MODEL #CBH17 -95V -3 WEIGHT = 357 lbs EXIST 16" JOIST - - - PARTIAL EXISTING ROOF FRAMING PLAN SCALE: 1/4" = 1' -0" STRUCTURAL NOTES: 1. CONTROLLING BUILDING CODE: 1997 UNIFORM BUILDING CODE DESIGN ROOF LIVE LOAD: 20 PSF 2 EXISTING ROOF CONSTRUCTION: MR DECK ON BAR JOISTS 0 4' -10 "- O.C. 3 IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE TO INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES, BUT IS NOT LIMITED TO, THE ADDITION OF WHATEVER TEMPORARY BRACING, GUYS OR TIE -DOWNS THAT MAY BE NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER COMPLETION OF THE PROJECT. 4 FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION. ROOF TOP UNIT DIMENSIONS SHALL BE COORDINATED WITH APPROVED RTU MANUFACTURER DRAWINGS. 5 SUPPORT FRAMING SHOWN IS FOR THE MECH UNITS SPECIFIED ON MECHANICAL DRAWING. IF A DIFFERENT UNIT IS TO BE USED, CONTACT ENGINEER BEFORE PROCEEDING. 6 ALL STEEL SHALL BE ASTM A36. 9 WELDING ELECTRODES SHALL BE E70XX, LOW HYDROGEN. 7 STRUCTURAL STEEL SHALL CONFORM TO THE AISC "SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS "_ (LATEST EDITION) 8 ALL WELDING SHALL BE DONE IN ACCORDANCE WITH "AMERICAN WELDING SOCIETY SPECIFICATIONS (LATEST EDITION). NO STRUCTURAL DRAWINGS WERE AVAILABLE AT TIME OF DESIGN. BEFORE FABRICATION OF MECH EQUIPMENT SUPPORT STEEL AND BEFORE INSTALLATION OF HVAC DUCTWORK, CONTRACTOR SHALL LOCATE EXISTING BUILDING DRAWINGS AND FORWARD TO STRUCTURAL ENGINEER FOR REVIEW /ANALYSIS & WRITTEN APPROVAL. IF NO STRUCTURAL DRAWINGS ARE AVAILABLE, CONTRACTOR SHALL FIELD MEASURE THE FOLLOWING MEMBERS, AND FORWARD INFORMATION TO STRUCTURAL ENGINEER FOR REVIEW /ANALYSIS & WRITTEN APPROVAL BEFORE FABRICATION OF MECH EQUIPMENT SUPPORT STEEL AND BEFORE INSTALLATION OF HVAC DUCTWORK: 1. COLUMN SIZE & SPACING. 2. STEEL BEAM SIZE & SPACING (DEPTH, FLANGE WIDTH & THICKNESS). 3. BAR JOIST SIZE & SPACING (DEPTH, CHORD /WEB SIZES, SPACING & THICKNESSES). NOTE: IF BAR JOISTS ARE TAGGED SHOWING JOIST SIZE, THEN FIELD MEASUREMENT IS NOT REQUIRED. 4. ROOF SLAB CROSS- SECTION, INCLUDING ROOFING MATERIAL & INSULATION. FIELD MEASUREMENTS OF STEEL MEMBERS MUST BE EXACT DIMENSIONS AND NOT "NOMINAL" DIMENSIONS, TAKING INTO CONSIDERATION THE THICKNESS OF PAINT OR OTHER COATINGS. FORWARD INFORMATION TO: PAUL J.. FORD & COMPANY STRUCTURAL ENGINEERS 250 E. BROAD ST, SUITE 500 COLUMBUS. OH 43215 ATTN: GREG K1.APHO E PHONE NO. (614) 221 -6679 FAX NO (614) 220 -4056 IF CONTRACTOR DOES NOT PROVIDE THIS INFORMATION, THEN CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY AND LIABILITY FOR INSTALLATION AND STRUCTURAL SUPPORT OF MECHANICAL EQUIPMENT. LILL EXIST BAR JOIST L4x4, TYP ROD CONNECTION TO SUPPORT FRAME BY OTHERS DOUBLE NUT & LOCK WASHER TYP /16 SECTION SCALE: N.T.S. EXIST BAR JOIST - SPRING ISOLATOR, TYP 2 FIELD WELD L2x2x3/16 FROM LOAD LOCATION TO NEAREST TOP CHORD PANEL POINT. (TYP BOTH SIDES) L4x4x3/8 I ANL i AIM SUPPORT FRAME BY OTHERS 1/2"0 A36 ROD, TYP AHU UNIT SECTION SCALE: NTS SECTION SCALE: NTS DOUBLE NUT & LOCK WASHER L SUPPORT FRAME BY OTHERS L4 3/16 EXIST MTL ROOF DECK EXIST. BAR JOIST EXIST MTL ROOF DECK TYP 2 SPRING ISOLATOR, TYP 1/2"0 A36 ROD, TYP DOUBLE NUT & LOCK WASHER 1/2"0 A36 ROD ROD CONNECTION TO SUPPORT FRAME BY OTHERS SCALE: NTS 1 1 /2"- SECTION L4x4x3/8 I) 0 ,•-. ll g 00 CD 0 0 0 PAUL J. FORD AND COMPANY 250 EAST BROAD STREET SUITE 500 COLUMBUS, OH 43215 (614) 221 -6679 PJF JOB NO. 35003 -32 (1) Z C c .1- 0 0 Z Z Co Z 0 -J LU 0 CC C� w Co 0 CC L0 _ Q) 0 � F � ii! !NI � 9� � ��� iI 14 1/ 1 : N i b V1 11 0:111 111§21b1 1/1 iht 1614 1101. egi 111:1 qiNts AMU 111E1 REVISIONS: •••• R- DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: • —• . 1•1111111111111116 VIM DRAINING MOM 0 ti C 0 r bs I.- M04.1 H Z O O -, Woo caarr At Ct Y W Z 1 -161 < W\ =11C, f'V Z Z � � J a 0 0 0 0 0 I - W U W-) a p r � eL CL 0 O in 0 ' V1 C J irat 10/16/03 xc AAG GDR NCH UNIT SUPPORT PLAN • r lib w Ohio 43230 EXIST BEAM • FPVAV WIT COINIMOIL SYSTEM DETAILS SCHEDULE SUPPLIED BY DESCRIPTION CODED NOTES AND WIRING LEGEND SCHEDULE C) ITEM(S) PROVIDED BY EMS. HELD WIRING TERMINATION TO BE COMPLETED BY MC CONTRACTOR. CD TYPICALY, ONLY ONE CO2 SENSOR AND ONE OUTSIDE AIR SENSOR PER STORE WILL BE REQUIRED. (1) ALL CONTROL WIRE SHALL BE FURNISHED bf EMS AND INSTALLED BY MECHANICAL CONTRACTOR. CD M(S) PROVIDED BY AND INSTALLED BY OEM. CD ITEM(S) PROVIDED BY EMS. FIELD WIRED AND INSTALLED BY GC CONTRACTOR. ITEM(S) PROVIDED BY EMS AND INSTALLED BY WS. CD APPLIES TO STRIP CENTERS OR OUTDOOR LOCATIONS ONLY. OEM - Orig Omd IWOnsw* Manufocturer wS - integrated Facility Systems, pre manufactured and pre assembled structure that contairs6 frormlonmer, breoker panels communication equipment, EMS •quiprmot. etc. EMS - Energy Marogenumt System T/P - Twisted Pair T-STAT THERMOSTAT PELD - Job Stie EMS CON UNK - Daisy chained system submit bum. I. LSD&C shall provide an Energy Managernsoi System (EMS) to aulomalrecally control the twang, ventilormg,„ air conditioning equipment and lighling systems es specified herein and as shown on Ike drawings. AN EMS components 'voluted to perform the Wended sequence of operation ono to be furnished by LSIMiC and b• atoned by the mechanical Conlroder wilts Are exception of the factory mounted controls. (see drawings) 2. AN low voltage, correnunicallen and/or sensor wire sdhell be provided os part of the LSO&C furnished Energy Management System ond installed by Are Mechenical Corinsclor. Wiring must be installed al • nimi of le away form ony lighting fixtures. Volker* or any moilootio *mica& Olio ofirtoinfi is pervnilted. AN wiring arid equipment shall be totaled in accordance with latest edes of the national electric codes. local code and lowidlord requirements. Moles General Cambodian Wilbira lbe second week of coestructiewi. EMS components and wire 11Pla be shipped to the job site. Included with Ike shipment will be all necessary boiallalion docurnerdallion and dromiegs vehiclo describe the irestolislion ami commissioning of the Energy Management Sylielft. if needed the project superiedendevi may piece a Pismo cell to Ike responsible EMS Engineer • (714) BS3-4537 review The crodents ailed the documentellein remised. .3. A check Rot for kleilalislion s Are Emmy alemagernera Spasm mil be provided wink the EMS efluiPoomet, we stert-up is to be performed prior to coompletion and verification of Mlle chocidiell b General Cerdrecler. lids checklist is le be signed end serbmIllted Carlinerist Central *shwa (COM) Cerior prier Is iterting ibe commisiOning process. The comening process cemswit be bseed wrineist the oemptiled checlideeL 1- sate commiesiming of Ike MAC mini sputum mereiree the use ell en enelleg Obenu line. swell se • toe W the permessmi plume Sae ere est bedelbm& the jib Woe's pewee Sae eels be estmL 5. Wpm rea. sit cembre beim lbe ismonoi Cesibecter or deeigeolled 1115,11111111199110,111 teem LWOW Oniessle Service Setetens WI Cooler (UM) (see bellslistlen illecensemesilkse). ClICS samellellee • Sew Ter ceodrel ieveltsim noiteSe osaverdseissing lab Ilve illecbessieel Cesterectsr. PO Se selbulkilledl One the Ilisdlemloel cemitreeller mils ales and Mb jobs110 partings the reenete cesisiniseionivi. The leecloskist Cenhember vassed ellen ene beer Syr WV MIK gaol for Conselseients. ilbe esenplailen of Ste asseenbienbmg Ike eseend n ed Ste essibel ewdber is Tweed r Arnim Insineer andlit Ilse ler Beasseleg Combeeller sib Abe ceillivelse Wig .11/111 —s--I lire ipeteratibig Centiresier mast esegise the COM Msaller bag CsNier (114) 1115-4151 le will ISO Ike esv-olle vestemes el any er Imeler Ave asessie UPS CIONISSMIN wilts Me sseass bob% emeallisred by The COM ilonlitelmg Courner. a like ceen•iellen el Om ear posoes. eseder„ voll Imo the IlesT esvisterse el lite essistot nesuber le Ise Mr listismos CaReorder. eilll WNW* ISO Ste egoism los Sew sir es• egeselien. 7. I I esetbetsitor mu, bielleds esitylsead Istalled 0.104,41. Mita lab as Colleml 110111•••• maw. emmil slibmaist Op 'be ilmouggi Omakstem r Oft r ij H B K CONSULTANTS, LTD 171 CHARRING CROSS DR S SUITE 18 WESTERVILLE, OHIO 43081 (614)882-1199 • .1 , 0111114111,11:1 0 .‘"' r ' .4! % DME ISSUE& DIESOCD BY: DRAWN IT: MEMO If: 1 E R REVISIONS: pieeesi 10/16 . 03 JS 4S TO NEXT COMPONENT IN SYSTEM (IF APPUCAILE) SPLIT SYSTEM CONTROLLER DIAGRAM FROM oUTSIDE Ate SCISSOR CD C) I I LL 24 V COM 24 VAC NOTE: ALL HELD INSTALLED WIRING IS 18 GAUGE TWISTED PAIR. OUTSIDE AIR TEMP SENSOR MUST BE MOUNTED IN OUTDOOR LOCATION PREFERABLY IN SHADED AREA AND AWAY FROM DIRECT SUN BEATING ROOF. EMS COM. LMK DIAGRAM TYPICAL ONE FAN COL UNIT SPLIT SYSTEM SEQUENCE OF OPERATIONS 1. FAN CONTROL A. SUPPLY FAN- The supply fan is controlled to run at all times during the occupied period and will cycle on and off during the unoccupied times based on the primary temperature sensor. It wRI prevent the space from rising above 85 degrees Fahrenheit or falling below 55 degrees Fahrenheit. 2. SPACE TEMPERATURE AND SET POINT ADJUST A. The slid* bar on the primary temperature sensor will be configured to provide local adjustment of +/- 2 degrees Fahrenheit. This will modify the heating and cooling set points accordingly, whether In occupied or unoccupied mode. B. If indicated on sheet (MO2.1), an additional sensor(s) will be installed as a temperature monitoring device(s) depending on the size of the space being controlled. 3. COOLING CONTROL A. Upon a call for cooling the first stage of cooling shall be enabled. This compressor shall run until the space temperature is satisfied. if the temperature in the space continues to climb because the first stage has not satisfied the cooling requirements, the second stage of cooling shall be enabled (if applicable). 4. HEATING CONTROL A. ELECTRIC/HOT WATER COL- Upon a call for heating the first stage of heating shall be enabled. This stage shall run until the space temperature is satisfied. If the temperature in the space continues to drop because the first stage is not capable of heating the space then the second stage of heating B. ai 1 larrotr the reversing valve is de-energized and the first st compressor shall be enabled. This stool shall run until the spoke temperature is If the temperature in the space continues to drop because the first stags is not capable of hoofing the space then the second slogs compressor shall be enabled (If applicable). 5. SAFETES A. SMOKE DETECTION - When the smoke detector is tripped, the unit shall be totally disabled. B . If any safeties, such as a freeze stat, float switch or any internal manufacturer safeties trip, they will activate the alarm relay. 6. ECONOMIZER CYCLE A. Economizer mode will be operational when the outside air temperature is between programmed set rira and may run in conjunction with the compressor(s). The economizer may also be utilized n shedding condifions. 7. SCHEDULES A. SCHEDULES - The schedules may be programmed for lime of day/day of week/holidays/special •vents/for full y•ar/accurate to within one minute. B. SYSTEM CLOCK-The system clock automatically adjusts for daylight savings time. 8. CO2 MONITORING A. Minimum outside air intake will be closed for CO2 levels below 900 ppm as long as economizer is not enabled. - FAN START/STOP ▪ 1f1 (COOL 1) / COMP. ▪ Y2 (COOL. 2) / COMP 2. ▪ WI (HEAT 1) / REVERSING VALVE(S) ACTIVATE FOR COOUNG - • W2 (HEAT 2) (AS REQUIRED) "Tr 20 19 IS 17 16 IS 14 13 12 11 10 +9 +7 A. UNIT modulates damper open on a call for cooling when the space temperature rises above the occupied setpoint. When the space temperature drops below the occupied set point the damper modulates back to the ventilation position. B. UNIT can be configured for morning warm up using heat resident on the RTU, AHU. OR FCU. C. UNIT operates on reheat, for a call for heating upon a drop in space temperature below the occupied setpoint. On a call for heat the damper modulates back to vent mode, the fan is energized and the reheat is enabled. When the reheat is electric the duct heater is activated to satisfy space temperature setting. When the reheat is hot water, the hot water valve is opened to satisfy space temperature setting. When satisfied the reheat shuts down and the fon shuts down. The unit returns to ventilation mode. Comfort ID controller communicates with the Rooftop unit to establish system demand for cooling. Through linkage the Damper can be driven closed for smoke shutdown or smoke evacuation mode of operation to meet these sequences. Through linkage the Damper can be driven open for smoke pressurization mode of operation to meet these sequences. FPVAV CONTROLLER WITH ACTUATOR DIAGRAM TUBING TO VAV AIR PROBE TIPS TO NEXT SENSOR APPUCABLE) FPVAV UNIT SEQUENCE OF OPERATIONS TYPICAL FPVAV UNIT TO NEXT COMPONENT IN FROM PREVIOUS COMPONENT 173 —ccilaitcluilt ill oar FROM AIR TEMP -«- FAN START/STOP FROM PREVIOUS COMPONENT IN SYSTEM (IF APPUCALILE) 1. SWITCHES AND LED's HEADEND AND LIGHTING CONTROLLER DIAGRAM ZONE 0 ZONE C ZONE • ZONE A Lc F F 2. 120V/24V TRANSFORMER FROM PHOTO CELL A. 120/24 V Transformer w81 typically NOTE: ALL FIELD INSTALLED WIRING IS TWISTED PAIR. HEADEND ASSEMBLY NOTES EMS COMM LINK DIAGRAM TO ft INLAY MIL ZONE C ZONE B ZONE A I I I I I I — 0 TELEPHONE RJ11 JACK be installed on plug mold in Switches are momentary push buttons. Indicators are 12 VDC LED's. Switches and indicators are mounted together and are labeled. Override package provided by EMS If applicable. If code jurisdiction requires a remote installation, then switches and LED's will be provided in special panel for field installation. this project then 120/24 V field mounted over J-box and • I.