Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 2523049071
Address: 1000 INDUSTRY DR TUKW
Suite No:
Tenant:
Name: TUKWILA COMMERCE CENTER - BLDG 30
Address: 1000 -1016 INDUSTRY DR, TUKWILA WA
Owner:
Name: CALWEST INDUSTRIAL PROP Phone:
Address: CIO DELOITTE & TOUCHE LLP, 2235 FARADAY AVE #0
Contact Person:
Name: CHUCK MAHLUM
Address: 4910 15 AV NW, SEATTLE WA
Contractor:
Name: HAIGHT ROOFING COMPANY INC.
Address: P.O. BOX 70150, SEATTLE, WA
Contractor License No: HAIGHRC269QK
DESCRIPTION OF WORK:
TEAR OFF EXISTING ROOF TO WOOD DECK. INSTALL NEW BUILT -UP ROOF SYSTEM.
Value of Construction: $ $35,090.00
Type of Fire Protection: SPRINKLERS
Type of Construction:
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
DEVELOPMENT PERMIT
Permit Number: D03 -334
Issue Date: 11/03/2003
Permit Expires On: 05/01/2004
Phone: 206 784 -8414
Phone: 206 784 -8414
Expiration Date:05 /01/2004
Fees Collected: $833.38
Uniform Building Code Edition: 1997
Occupancy per UBC: 0016
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone: N
Hauling: N Start Time: End Time:
Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation: N
Moving Oversize Load: N Start Time: End Time:
Sanitary Side Sewer: N
Sewer Main Extension: N Private: n Public: n
Storm Drainage: N
Street Use: N Profit: N Non - Profit: N
Water Main Extension: N Private: n Public: n
N
Water Meter:
doe: Devperm
** Continued Next Page **
D03 -334
Printed: 11 -03 -2003
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
�t
/ "
Permit Center Authorized Signature: '���.t.Gl�- v Dat e: /c/
L ='
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construct' g r the performance of work. I am authorized to sign and obtain this development permit.
Date: `A. 'o c 3
Signature:
Print Name:
&f,t,6e4 "0#141-_.
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
doc: Devperm
D03 -334
Printed: 11 -03 -2003
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
PERMIT CONDITIONS
z
i t—
CL
J U
00
W
J =
H
w
LL <
w
I
f .. w
Z =
4: A statement from the roofing contractor verifying fire retardant class of roof will be required prior to final F-
HO
inspection (see attached procedure). z F—
• w
5: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997
Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). p
O 1-
6: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be = w
construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any H H
other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this L- p
code shall be valid. tii Z
co
O ~
z
Parcel No.: 2523049071 Permit Number: D03 -334
Address: 1000 INDUSTRY DR TUKW Status: ISSUED
Suite No: Applied Date: 10/29/2003
Tenant: TUKWILA COMMERCE CENTER - BLDG 30 Issue Date: 11/03/2003
1: ** *BUILDING DEPARTMENT CONDITIONS* **
2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division.
3: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any
construction. These documents are to be maintained and available until final inspection approval is granted.
7: The following conditions apply to re -roof permits:
1. All re- roofing projects will be accomplished in compliance with Appendix Chapter 15 of the Uniform Building Code
(UBC).
2. Inspections: a) New roof coverings shall not be applied without first obtaining a pre- roofing inspection
from the Building Division and written approval from the Building Inspector. The pre- roofing inspection shall pay
particular attention to evidence of accumulation of water. Where extensive ponding of water is apparent, an analysis of
the roof structure for compliance with section 1506, U.B.C., shall be made and corrective measures, such as relocation
of roof drains or scuppers, resloping of the roof or structural changes, shall be accomplished. An inspection covering
the above listed topics prepared by a qualified special inspector, as determined by the Building Official, may be
accepted in lieu of the pre- inspection by the Building Inspector. b) A final inspection and approval shall be obtained
from the Building Division when the re- roofing is complete. As a condition of the final inspection for roofs that
require a fire retardent roof covering under the provisions of Table 15 -A, 1997 U.B.C., the roof installer shall
provide the inspector with a written statement indicating the following (or something similar):
"I have installed a roof membrane assembly, including insulation if applicable, consisting of (manufacturer),
Specification No. , data sheet enclosed, which meets or exceeds the requirements for Class A or Class B roofs.
This roof was installed at (address), under City of Tukwila Building Permit No.
(NOTE: This statement shall include the name of the roofing company that installed the roof, signature of installer and
date.)
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
doc: Conditions
D03 -334
.Sx�:il�i',Cijlk:a±ttsl ':sv 41AS bSW:u .:+'$'C �iei sril�:'. !, �.
Printed: 11 -03 -2003
doc: Conditions
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670
regulating construction or the performance of work.
D03-334
,,••••••■•
Date: A3.-to
Printed: 11-03-2003
Site Address: i0c0- 101k, ►t-\D'- i 2� I?�
Tenant Name: O taP'A i a-1 17210e SLAY -NJ ILA, CC,,...10N c..0- 1TL- 42,New Tenant: .... Yes 15,.No
Property Owners Name: ' tvl�svi T CzDt..tPph l`r
Mailing Address: 1(GEDD C.+- -16T 1 4p k [CA 'T v41/4.) vJA 9c3 (63S
City State Zip
Name: c -tc.\(.W._ 0/ t KA
Mailing Address: Act (tJ t D AvE A.A.)
E -Mail Address: •I'►ukc - ha 11/1+(o0 -(%41 . Gcn'1
Company Name: (- 1 {►tAlo
Mailing Address: q° i o Lc', 1 -1 l Av.)
Contact Person:
E -Mail Address:
Contractor Registration Number: t4POGi- P- c-ZL4 O. --
Company Name: D C �►.� 5:- L- t k 1 (►, L.
Mailing Address: 4\ 01 W �S1 r L-1 -7� Ac-� t o�
Contact Person:
E -Mail Address:
Contact Person:
E -Mail Address:
\applications \permit application (3.2003)
3/2003
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
Gt.kc_.c_ _- Lt�CZCZ
Page 1
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print*
King Co Assessor's Tax No.: ra2o�a T ' fb7/
Suite Number: Floor:
Day Telephone: 2c - - 764 -- al 4-
kA)A ggt U'
SL
City State Zip
.coo
Fax Number:
City
Day Telephone:
Fax Number:
Expiration Date: CS /c,Z 12Cx�-
**An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
ARCHITECT RECORD : —Ail p lans: must be`
OF we tamped: by Architect:of Record
CA g21.c+v0
City
w
State
98t 0
Zip
State Zip
Day Telephone: 6 14 4 3 - y55 - 2 7 7
Fax Number: C'1 19 - 2-9
=: OFrRECORD ` Ail:pians must bewet tamped by:Engineer -of Record
Company Name: t ( A
Mailing Address:
City
Day Telephone:
Fax Number:
State
!CY
Zip
ILRING, PERMIT INFORM `' Ib = 2Od 6431 -36
41* tes
Valuation of Project (contractor's bid price): $ E S / pq
Scope of Work (please provide detailed information):
vJot:7��
Will there be new rack storage? ❑ ..Yes D.. No
\applications \permit application (3 -2003)
3/2003
Page 2
Existing Building Valuation: $
•
if "yes ", see Handout No. for requirements.
Provide All Building Areas in Square Footage Below
to
Existing
Structure
Floor;:
3`a Floor
:Floors hru:
Basement :'
Accessory Structure*
Attached •. •
Detached Garage
Attached Carport;
;Detached Carport:
Covered Deck
Uncovered Deck
Interior
Remodel.
Type of
Construction
per UBC
Type of
Occupancy per.
UBC
PLANNING DIVISION:
Single- family building footprint (area of the foundation of all structures, plus.any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
› ❑..Automatic Fire Alarm El _None El . Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 ..Yes No
If "yes", attach list of materials and storage locations on a separate 8-1/2 x 11 paper indicating quantities and Materia Safety Data Sheets.
t
Ps:
i.'f x.`•':5;4 +t
❑ ...Total Cut
❑ ...Total Fill
FINANCE INFORMATION
Fire Line Size at Property Line
❑ ...Water ❑ ...Sewer
Monthly Service Billing to:
Name:
Mailing Address:
Water Meter Refund /Billing:
Name:
Mailing Add esk.x' 4
S: RMIT =:
\applications \permit application (3.2003)
3/2003
cubic yards
cubic yards
❑...Sanitary Side Sewer
❑ . ..Cap or Remove Utilities
❑ ...Frontage Improvements
❑ ,..Traffic Control
❑ ...Backflow Prevention - Fire Protection
Irrigation
Domestic Water
❑ ...Permanent Water Meter Size...
❑ ...Temporary Water Meter Size..
❑ ...Water Only Meter Size
❑ .. Main Extension Public _
❑ ...Water Main Extension Public _
„
„
„
tMATIO
Scope of Work (please provide detailed information):
Water District
❑ ...Tukwila ❑ ...Water District #125
❑ ...Water Availability Provided
Submitted with Application (mark boxes which apply):
❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ")
❑ ...Technical Information Report (Storm Drainage)
❑ ...Bond ❑ .. Insurance ❑ .. Easement(s)
Sewer District
❑ ... Tukwila ❑... ValVue ❑ .. Renton ❑ ...Seattle
❑ ...Sewer Use Certificate ❑ ... Sewer Availability Provided ❑ .. Approved Septic Plans Provided
❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department.
Call before you Dig: 1- 800 - 424 -5555
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Proposed Activities (mark boxes that apply):
❑ ...Right -of -way Use - Nonprofit for less than 72 hours
❑ ...Right -of -way Use - No Disturbance
❑ ...Construction/Excavation/Fill - Right -of -way
Non Right -of -way
. Abandon Septic Tank
. Curb Cut
. Pavement Cut
. Looped Fire Line
„
„
WO#
WO#
WO#
Private
Private
❑ .. Highline
'z. • Rs7 r9
❑ ...Renton
❑ .. Geotechnical Report ❑...Traffic Impact Analysis
❑ .. Maintenance Agreement(s) ❑...Hold Harmless
❑ .. Right -of -way Use - Profit for less than 72 hours
❑ .. Right -of -way Use — Potential Disturbance
❑ .. Work in Flood Zone
❑ .. Storm Drainage
Number of Public Fire Hydrant(s)
❑ ...Sewage Treatment
•
Page 3
❑ .. Grease Interceptor
❑ .. Channelization
❑ .. Trench Excavation
❑ .. Utility Undergrounding
❑ ...Deduct Water Meter Size
Day Telephone:
City
State
Zip
Day Telephone:
City , . ;Statq
�tS$iS� °r �Fws'.�iF l'4f5wgid
Unit Type:. "
Qty >
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
.Qty
Furnace <100K BTU
Air Handling Unit
>= 10,000 CFM
Other Mechanical
Equipment
0 -3 HP /100,000 BTU
Furnace>100K BTU
Evaporator Cooler
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan
15 -30 HP /1,000,000 BTU
Suspended /Wall /Floor
Mounted Heater
Ventilation System
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood
50+ I -IP /1,750,000 BTU
Heat/Refrig /Cooling
System
Incinerator - Domestic
Air Handling Unit
<= 10,000 CFM
Incinerator — Comm /Ind
MECHANICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address:
City State Zip
Day Telephone:
Fax Number:
Expiration Date:
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
Contact Person:
E -Mail Address:
Contractor Registration Number:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Indicate type of mechanical work being installed and the quantity below:
Use: Residential: New .... ❑ Replacement .... ❑
Commercial: New .... ❑ Replacement .... ❑
Fuel Type: Electric ❑ Gas ....❑ Other:
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as
defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWN,. / A THORIZED AGENT:
Signature: f Date:
Print Name: /PSG— - 4 u t`i
Mailing Address: 4q(c) t Sn-∎ Av.)
Day Telephone: 2(x2 - - 764 -
v.1A 98)0 - 7
State Zip
City
Date Application Accepted:
Date Application xpires:
I
Staff •
\applications\permit application (3.2003)
3/2003
Page 4
TRANSACTION LIST:
ACCOUNT ITEM LIST:
Description
doc: Receipt
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
z
RECEIPT
,�W
CC Parcel No.: 2523049071 Permit Number: D03 -334 6 v
Address: 1000 INDUSTRY DR TUKW Status: APPROVED o 0
Suite No: Applied Date: 10/29/2003 W =
Applicant: TUKWILA COMMERCE CENTER - BLDG 30 Issue Date: L u F ,
W 0
Receipt No.: R03 -01327 Payment Amount: 220.40 ga n
I.L. a
co
Initials: LAW Payment Date: 11/03/2003 12:07 PM =
User ID: 1630 Balance: $0.00 i _
Z 1-
11- 0
Z 1-
Payee: HAIGHT ROOFING COMPANY INC D 0
0
O N
O 1--
W —
Type Method Description Amount I U
L I
F-
Payment Check 23475 220.40 Z
U1 co
1-- H
O
z
BUILDING - NONRES 000/322.100
STATE BUILDING SURCHARGE 000/386.904
Account Code Current Pmts
215.90
4.50
Total: 220.40
— 4701 .1,1 04 971.6 TOTAL 220.40
Printed: 11 -03 -2003
Parcel No.:
Address:
Suite No:
Applicant:
Receipt No.:
Initials:
User ID:
Payee:
TRANSACTION LIST:
Type Method
doc: Receipt
Payment
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
2523049071
1000 INDUSTRY DR TUKW
TUKWILA COMMERCE CENTER - BLDG 30
R03 -01313
SKS
1165
ACCOUNT ITEM LIST:
Description
HAIGHT ROOFING COMPANY, INC.
Check 23474
BUILDING - NONRES
PLAN CHECK - NONRES
Description
RECEIPT
Account Code
000/322.100
000/345.830
Permit Number:
Status:
Applied Date:
Issue Date:
Payment Amount:
Payment Date:
Balance:
Amount
612.98
Current Pmts
286.45
326.53
Total: 612.98
D03 -334
PENDING
10/29/2003
612.98
10/29/2003 02:07 PM
$220.40
7 1 J0/29 9716 TOTAL 1101.34
Printed: 10 -29 -2003
Z
Z
cc
0 0
CO ILI
J
CO Li.
w
g
(.2 d
w
z1
1--0
Z 1-
O N
0
W W
0
O
.Z
W
U =
O 1—
z
•
Project:
C. T� \u Cow, . CA e.
Type of Inspection:
Address:
Woo _ 1011.0
rJVS4.,.
Date Called:
Special Instructions:
I
Date Wanted:
a.m.
p.m.
Requester:
Phone No:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
133 - 33
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Approved per applicable codes. n Corrections required prior to approval.
COMMENTS:
C P t v P! 1 `t- 1 via
A P v m i4- l Oven 1-e 4--f
Inspector { c v
Date / I _ CL)
$47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
SS
Pr
Type of Inspection:
Addre
MO— ss: /O /
/ t
Date Calle 5 /2S/
Special Instructions:
9" ..lt .e)
Date Wanted: (
Requester:
Phone No:,
2)6-9.Z -- 19 2 7
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PE R 4 l
(20 • )431 -3670
Approved per applicable codes.
COMMENTS:
VVA l )-e recJr cj
Inspecto
tr?c1/4,,,Pv
'Corrections required prior to approval.
Date:
5y)-149-01"
E] $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
"SINCE 1919"
April 28, 2004
Stephania Spencer
City of Tukwila — Permits Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
RE: Permit Application No. D03 -334 — Request for Extension
Dear Ms. Spencer:
We respectfully request a one -time extension for this permit, as we were unable to
complete the project prior to cold weather setting in last year.
The roof is complete with exception to the cap sheet, which should be set in temperatures
above 60 degrees when feasible. We are now beginning our roofing season and expect to
complete this project within the next couple of weeks, at which point we will be able to
call for final inspection.
Thank you again for your help in this matter.
Sincerely,
Haight Roofing Company, Inc
Chuck Mahlum
Project Manager
CC: File
Original to follow via US Mail
HAIGHT ROOFING COMPANY, INC.
Mailing Address: P.O. Box 70150, Seattle, WA 98107 Area Code: (206) 784 -8414
INDUSTRIAL - COMMERCIAL - ROOFING and SHEET METAL WORK Fax: (206) 784 - 1058
INSULATING CONCRETE ROOF DECKS
REROOFING SPECIALISTS
Via Facsimile
206 - 431 -3665
Members: Western States Roofing Contractors Association / National Roofing Contractors Association
Washington State Contractors Registration Number HA- IG- HR- C269QK
1
"SINCE 1919"
May 27, 2004
Stephania Spencer
City of Tukwila — Permits Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
RE: Letter of Completion
Dear Ms. Spencer:
HAIGHT ROOFING COMPANY, INC.
Mailing Address: P.O. Box 70150, Seattle, WA 98107 Area Code: (206) 784 -8414
INDUSTRIAL - COMMERCIAL - ROOFING and SHEET METAL WORK Fax: (206) 784 - 1058
INSULATING CONCRETE ROOF DECKS
REROOFING SPECIALISTS
We have installed a roof membrane assembly, including insulation if applicable,
consisting of GAF Materials Corporation, Specification No. N- B -M/P6, data sheet
attached, which meets or exceeds the requirements for Class A or Class B roofs.
Sincerely,
Haight Roofing Company, Inc
Chuck Mahlum
Project Manager
CC: File
This roof was installed at1000 —1016 Industry Drive under City of Tukwila Building
Permit No. D03 -334.
Members: Western States Roofing Contractors Association / National Roofing Contractors Association
Washington State Contractors Registration Number HA- IG- HR- C269QK
GAFGLAS® Specifications N- B- 4 -M /P6 and N -B -4 -M
GAFG1 Ply
GAFGLAS
Mineral Surfaced
Ca Sheet
� 2"11daLap --
Natlabie Deck
• Sheathing Paper
(If required)
Sete Sheet
(see below)
:. Rooting
Asphalt
`. :.c
2" Side Lap
25
7
1 .'rr?; ;) 7n(in
Nailable decks up to 6 inches per loot slope, except for lightweight insulating
concrete decks which are limited to a maximum slope of 1" per foot. Wood,
plywood, poured gypsum, precast gypsum planks, other acceptable nailable
decks For lightweight insulating concrete decks. see page 9.
Materials
Sheathing paper (1 ply, if reg'ec
Base Sheet : �'`.t;
GAFGLAS Ply (2 plies)
GAF Materials Corporation Roofing
Cap Sheet ,: r:• ;. :ir,;rlt
GAFGLAS Mineral Surfacedtap Sheet
Approximate Weight per Square-,
;175 -250 Ibs.'::,
Design and Application Considerations detailed in this Manual shall apply in
addition to the following recommendations and specifications.
1 Over entire surface. lay one ply of sheathing paper where applicable. Lap
eacn sheet 2 inches over preceding sheet. Nail sufficiently to hold in place.
2 Starting at the low point of the roof, lay one ply of Base Sheet, lapping each
sneet 2 inches at edges and not less than 6 inches at end laps. Nail along lap
of base ply at intervals not to exceed 9 inches and stagger -nail down center of
sheet in two rows with nails spaced at 18 inch intervals in each row. Use fas-
teners with integral metal heads at least 1 inch in diameter or square that are
r ecommended by GAF Materials Corporation or the deck manufacturer. (See
'Special Instructions below.)
3 Starting at the low point of the roof, mop two plies of GAFGLAS Ply shingle
fashion: lapping each sheet 20 V1 inches over the preceding sheet: solidly
mopping to the underlying base sheet to provide three plies over the entire
roof area.
iInterpty moppings of Roofing Asphalt must be applied in a continuous film and
shall consist of approximately 25 pounds per 100 square feet of root area with
a tolerance not to exceed 20% plus or minus. The appropriate asphalt for the
slopes involved must be used.
' „r.,!- "TO'w"vr.,rT}\r,,. Pert , rv40.1•L! /tU -'-
jt' ; i'Ti
•
GAF MATER
CORPORATION
Slope per foot . Asphalt Type
Up to 3' Steep ASTM Type III
3 "- 6' HT -Steep ASTM Type IV
On slopes up to'/ inch per foot. Flat ASTM Type II may be used except in
Florida, Texas, New Mexico, Arizona, and California.
Apply GAFGLAS Mineral Surfaced Cap Sheet in accordance with the application
instructions on page 20, so that the laps are offset from the laps of the ply sheets
1. See recommendations for use over gypsum decks on page 9.
2. Acceptable Base Sheets include: STRATAVEN7 Nailable required for Ireshly
poured gypsum decks, GAFGLAS #75 Base Sheet. RUBEROID' Modified Base
Sheet, GAFGLAS"FlexPly6, and GAFGLAS Ply 4. For wood decks and structural
wood fiber decks, when GAFGLAS Ply 4 or GAFGLAS' ;FlexPl76 is used as a
base sheet, a sheathing paper is required.
3. See "Nailing of Base Sheet," page 19.
4. For roof slopes of 1 inch per foot or more. all ply felts must be back - nailed 4
inches in from the back edge of the felt. See "Installation on Steep Roofs.' page 10.
'.11f...
UL Class .
Substrate .
Slope
„ C .
NC
C
2 ..
3'
3 ' /i
1. Substrate
C = Combustible and Noncombustible
Combustible = Wood planks, boards, etc., plywood (min. 'VI? inch thickness).
oriented strand board (min. ' /2 inch thickness).
NC = Noncombustible only
Noncombustible = Steel, poured or precast structural concrete. lightweight
insulating concrete, gypsum, structural wood fiber, etc.
2. Slope
Maximum slope allowed, in inches per foot.
Guarantees Available
Specification Liberty Guarantees
N- B- 4 -M/P6
N- B- 4 -M /P6
N -B -4 -M
15,12, 5 yr. West Zone only, Wood Decks.
15,12,10,5yr.
Lightweight Insulating Concrete. (See page 9.)
12, 10, 5 yr.
4 1
"SINCE 1919"
October 29, 2003
City of Tukwila
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
Dear Examiner:
Sincerely,
Haight Roofing Company, Inc.
Enclosures
Charles E. Mahlum
Project Manager
KO CHANGES SHALL SE M, OS TO
7-3:7 SCOPE OF F ''OINK WITHOUT FAK.:4•:..
OF TUKWiLA i- ,UILDI s�' ....
EOTE: REVISIONS WILL REQUIRE A NEW PLAN SUEStanil
MID WAY Ind LLIOE ADDITIONAL PLAN FIEVICW FEES:
HAIGHT ROOFING COMPANY, INC.
Mailing Address: P.O. Box 70150, Seattle, WA 98107 Area Code: (206) 784 - 8414
INDUSTRIAL - COMMERCIAL - ROOFING and SHEET METAL WORK Fax: (206) 784 - 1058
INSULATING CONCRETE ROOF D
REROOFING SPECIALISTS FILE COPY
I understand that the Plan Check approvals are
subject to errors and omissions and approval of
plans does not authorize the violation of any
adopted code or ordinance. Receipt of con-
tractor's copy of approved plans acknowledged.
CITY Of OYOl�
OCT 3 NO
A6 NO i LU
j ib- - 76 - bi — CMY )
By �l
Date •0
Permit No.
RE: Narrative of re -roof at 1000 —1016 Industry Drive, Tukwila, WA
«Gv b „ z�A` r.`^:. w?' k:. s: 6il�fy` S, h: t..• :�11r'.i«t}.s?a ":;.14'�?P7'u�;
The existing roof system for the above mentioned location is: 1/2" plywood covered with
two plies of fiberglass roofing felt set in roofing asphalt and a mineral surfaced cap sheet
set in roofing asphalt completes the system. Others have patched numerous areas with
various roofing products in attempted repairs. The system is in otherwise good condition
and not currently leaking.
Using GAF Roofing Products we will tear off the existing system to wood deck; sweep
broom clean; nail red rosin and base sheet. We will then solidly set two plies of
fiberglass roofing felt in hot asphalt and cap with a mineral surfaced sheet also set in hot
asphalt.
RECEIVED
CITY OF TIJKWII '
OCT 2 9 2003
PERMIT CENTEF
bc 3y
Members: Western States Roofing Contractors Association / National Roofing Contractors Association
Washington State Contractors Registration Number HA- IG- HR- C269QK
April 29, 2004
Mr. Chuck Mahlum
Haight Roofing Company, Inc.
P.O. Box 70150
Seattle, Washington 98107
City of Tukwila
Steven M. Mullet, Mayor
Dear Mr. Mahlum:
Department of Community Development Steve Lancaster, Director
RE: Request for Extension — Permit No. D03 -334 —1000 Industry Drive — Bldg 30
This letter is in response to your written request for an extension to Permit No. D03 -334. Based on the
information received, the City of Tukwila Building Division will be extending your permit to
November 1, 2004.
Please be advised that this will be the only extension granted for this project and no further notice will
be given prior to the expiration date. A new permit and associated fees will be required after the
above -noted expiration date.
If you should have any questions, please contact our office at (206) 431 -3670.
Sinc 1y,
G►bd
Robbrt Benedicto
Building Official
/sks
File: Permit No. D03 -334
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206-431-3665
Sent By: HAIGHT ROOFING CO INC; 2067841058; Apr -28 -04 3:19PM; Page 2/2
"SINCE 1919"
April 28, 2004
Stephania Spencer Via Facsimile
City of Tukwila — Permits Center 206 -431 -3665
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
RE: Permit Application No. D03 - 333 — Request for Extension
Dear Ms. Spencer:
We respectfully request a one -time extension for this permit, as we were unable to
complete the project prior to cold weather setting in last year.
The roof is complete with exception to the cap sheet, which should be set in temperatures
above 60 degrees when feasible. We are now beginning our roofing season and expect to
complete this project within the next couple of weeks, at which point we will be able to
call for final inspection.
Thank you again for your help in this matter.
Sincerely,
Haight Roofing Company, Inc
Chuck Mahlum
Project Manager
CC: File
Original to follow via US Mail
HAIGHT ROOFING COMPANY, INC.
Mailing Address: P.O. Box 70150, Seattle, WA 98107 Area Code: (206) 7848414
INDUSTRIAL - COMMERCIAL - ROOFING and SHEET METAL WORK Fax: (206) 784 - 1058
INSULATING CONCRETE ROOF DECKS
REROOFING SPECIALISTS
RoFE ED
oiTY
ApR 2 8 200
PERMIT CENTER
Members: Western States Roofing Contractors Association / National Roofing Contractors Association
Washington State Contractors Registration Number HA- IG- 1-1R- C269QK
�l :i :rd;id.4w�.1:�n,. 214 :� :zu,•�;iiti'r D i <(..4rx,4r « .::i <a:L.�:vi3
April 6, 2004
Chuck Mahlum
4910 15th Avenue NW
Seattle, WA 98107
Dear Permit Holder:
City of Tukwila
Department of Community Development Steve Lancaster, Director
RE: Permit Application No. D03 -334
1000 Industry Drive
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila
Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the
Building Official under the provisions of this code shall expire by limitation and become null and void if the
building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work. is
commenced for a period of 180 days.
Based on the above, you are hereby advised to:
• Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final
inspection.
Steven M. Mullet, Mayor
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit
or last inspection; or if the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve a one -time
extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection or request and receive an extension prior to May 1, 2004,
your permit will become null and void and any further work on the project will require a new permit and
associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Stefania Spencer
Permit Technician
Xc: Permit File No. D03 -334
Bob Benedicto, Building Official
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206-431-3665
'l'irR+b. tit F,:r k *CYIfi2?� M
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D03 -334 DATE: 10 -29 -03
PROJECT NAME: TUKWILA COMMERCE CENTER - BLDG 30
SITE ADDRESS: 1000 -1016 INDUSTRY DRIVE
X Original Plan Submittal Response to Incomplete Letter # -
_Response to Correction Letter # Revision #_after /before permit is issued
DEPARTMENTS: J
mil' AV 1(7— U —U.5
Buildin Div sion
Public Works ❑
Documents /routing slip.doc
2.28 -02
511 Plitt_ it* .I -13
Fire Prevention
Structural El
Planning Division
Permit Coordinator
DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10 -30 -03
Complete Incomplete ❑
Comments:
REVIEWER'S INITIALS:
PERMIT COORD COPY
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route , Di Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 11 -27 -03
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
A: 3s�:: s.' C: x: is�' ir: l� :Fr.uyJ?v;ii'iadidkZU?t'k%ri' •cty- �i�a9ait xh:.tal:u a. YS.4. ` > - :r.
r..
State of
Washington
DEPARTMENT OF LABOR AND INDUSTRIES
REGISTERED AS PROVIDED BY LAW AS
CONST,CONT GENERAL
.,,.....:
CC 01 ✓ :HAIGHRC26'9QK" 05/02 /2004
EFFECTTVE`DATE 11/12/1974
HAIGHT ROOFING COMPANY INC
PO BOX.70150
SEATTLE WA 98107
DEPARTMENT OF LABOR & INDUSTRIES
PO BOX 44450
OLYMPIA WA 98504 -4450
HAIGHT ROOFING COMPANY INC
PO BOX 70150 •
SEATTLE WA 98107
DL? F&DF, WA.
vzs
FIRST CLASS MAIL
US POSTAGE
PAID
10,LY ']Al 1
PERMIT NO 312
Z
Z
— I C.)
UO
co CI
W =
J 1.-
I L
1.
w al
2 • o
0
O
co
� I—
W • w
' • O
1 z
I U , .
O
z