HomeMy WebLinkAboutPermit D03-349 - DHS BUILDING - WALL NDHS BUILDING - WALL "N" 12500 TUKWILA INTERNATIONAL BOULEVARD D03 -349 z • Z • W. U0 U � W =' W 0 2 • u. Na =W Z� 1- 0 Z 2o U �O N WW 2 1- U_ 0 W Z UN O Z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 DEVELOPMENT PERMIT Parcel No.: 7340600602 Address: 12500 TUKWILA INTERNATIONAL BL TUKW Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Value of Construction: $ $22,800.00 Type of Fire Protection: Type of Construction: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: doc: Devperm DHS BUILDING - WALL 'N' 12500 TUKWILA INTERNATIONAL BL, TUKWILA WA INTRNL GATEWAY EAST III 12201 TUKWILA INTRNTL BLVD, SEATTLE WA RALPH HAGLER 12201 TUKWILA INTERNATIONAL BL, TUKWILA WA SABEY CONSTRUCTION INC. Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 281 -8700 Phone: 206 - 281 -4700 Address: 12201 TUKWILA INTERNATIONAL BLVD, SEATTLE WA Contractor License No: SABEYCI033KM Expiration Date:01 /06/2005 DESCRIPTION OF WORK: CONSTRUCTION WALL "N" MODULAR BLOCK WALL FOR PORTION OF THE NORTH PARKING LOT. Public Works Activities: N N N N N N N N N N N N Private: N Profit: N Private: N D03 -349 D03 -349 12/31/2003 06/28/2004 Fees Collected: $935.86 Uniform Building Code Edition: 1997 Occupancy per UBC: Number: 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Size (Inches): 0 Public: Non - Profit: Public: N N N Printed: 12 -31 -2003 Permit Center Authorized Signature: Signature: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Date: % - 3- / - t3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating conviction or perf mance of work. I am authorized to sign and obtain this development permit. Date: 12.(10). Print Name: f 4.%tt`j �EN This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D03 -349 Printed: 12 -31 -2003 Parcel No.: 7340600602 Permit Number: D03 -349 Address: 12500 TUKWILA INTERNATIONAL BL TUKW Status: ISSUED Suite No: Applied Date: 11/10/2003 Tenant: DHS BUILDING - WALL 'N' Issue Date: 12/31/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 4: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 5: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 6: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 7: Contractor shall notify Public Works Utility Inspector Mr. Greg Villanueva at (206)433 -0179 of commencement and completion of work at least 24 hours in advance. 8: Work affecting traffic flows shall be closely coordinated with the City Utilities Inspector. Traffic Control Plans shall be submitted to the Inspector for prior approval. 9: Flagging, signing and coning shall be in accordance with MUTCD for Traffic Control. Contractor shall provide certified flagmen for traffic control. Sweep or otherwise clean streets to the satisfaction of Public Works each night around hauling route (No flushing allowed). Notify City Inspector before 12:00 Noon on Friday preceding any weekend work. 10: Any material spilled onto any street shall be cleaned up immediately. 11: A copy of the Certificate of Insurance Coverage (minimum of $1,000,000 naming the City of Tukwila as additionally insured). 12: A map which shows the haul route. 13: Hauling over 50 cubic yards shall require application for a Hauling Permit prior to any associated activity. 14: Clean and remove debris from City catch basin in and around hauling routes. Provide adequate temporary access as not to interfere with other vehicle movement or cause trucks to travel over curbs. All vehicles must make a complete stop prior to entering public right -of -way. 15: Business License with the City of Tukwila. 16: Route Map. doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS D03 -349 Printed: 12 -31 -2003 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 17: From October 1 through April 30, cover any slopes and stockpiles that are 3H:1V or steeper and have a vertical rise of 10 feet or more and will be unworked for greater than 12 hours. During this time period, cover or mulch other disturbed areas, if they will be unworked more than 2 days. Covered material must be stockpiled on site at the beginning of this period. Inspect and maintain this stabilization weekly and immediately before, during and following storms. 18: From May 1 through September 30, inspect and maintain temporary erosion prevention and sediment at least monthly. All disturbed areas of the site shall be permanently stabilized prior to final construction approval. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: ` l Date: 1Z (117o3 Print Name: doc: Conditions D03 -349 Printed: 12 -31 -2003 King Co Assessor's Tax No.: Site Address: /06 TOki/Ulla l'ii g Tenant Name: Z N ea //c/iny &Atli "N " Property Owners Name: ■3 CC , rprla-'7? e3K Mailing Address: /2.2 0 / 7741/..; ' /0_, .Thter'h a z/ as. 7, GOA, ? g I 68 - 5721 City State Zip Name: Mailing Address: E-Mail Address: V,Y Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E-Mail Address: Contractor Registration Number: Expiration Date: **An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance** Company Name: Mailing Address: Contact Person: E-Mail Address: , • Company Name: Mailing Address: Contact Person: E-Mail Address: CITY OF TUKWIL4 Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** #097ek Day Telephone:P(4 2N-4700 / 7u4u}ila -Tn‘p-iieth'ov?al 1 5/4, 77;Auilk AA-, fg/68-57 ‘applicationslpermit application (3.2003) 3/2003 (.4t Lfrt rik/ ? E 'n - -V )• RECORDl plang MuSt be b ;En inee tieeeid o Li crioe_ V flta/ *tit e com „ Dk 'tit? .1; 4 ;i3ti Page 1 , Suite Number: State State Floor: New Tenant: 0 .... Yes 0 -No City State Zip Fax Number: Zip City Day Telephone: Fax Number: Zip Everat go City State Z p Day Telephone: ( 42S) Fax Number: (4 .zs 25f 577 1 nt"ta=erfitv.,Pas."4 z < • 1 uJ Z Ce —1 C.) 00 (1) 0 LLJ LL1 ui 0 2 g < 1 w z i- z uj O 0 • co O — O 1— 111 I 0 1— w z I I 0 O c° P O /— z ��. , . ' }:t: t {'•, 'C��' .. � ��'4't`� •i•" w ' 1Z, ( r' * • • I Valuation of Profect (contractor's bid price): $ 2. ) 0 ° Existing Building Valuation: $ om Scope of Work (please provide detailed information): C oY\, ('V`C ' 1 1 os, 1 It Q c _l a v b l e5 1 i Q, ` ( '1r cc U' t ov.. of- -)-Lki )1c- -- c•;1 -S u c Ici Vt. An o kr-k nav (ot" Will there be new rack storage? ❑ ..Yes ❑ .. No If "yes ", see Handout No. for requirements. it v All .0i14140 Area14,0:. aajre FogtageBelq 1 "'Floor 2 7 ..Floor 3" Floor Floors asement Accessory Structure' ., `Attached Garage i - Detached Garage Attached :Carport Detached Carport: Covered Deck 'Uncovered Deck ?'Addition do E fisting Structure: !':`: - Type;aif Con striicti.on 1per UBC PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 .... Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑.. Sprinklers ❑..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? .. Yes ❑ ..No If"yes", attach list of materials and storage locations on a separate 8 -1/2 x I I paper indicating quantities and Material Safety Data Sheets. \+pplicationskpermit application (3-2003) 3/2003 Page 2 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila 0... Water District #125 ❑ ... Water Availability Provided Sewer District ❑ ...Tukwila 0... ValVue ❑ .. Renton ❑ ...Seattle ❑ ...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ .. Right -of -way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill %applicationflpermit application (3.2003) 3/2003 ❑...Sanitary Side Sewer ❑...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water Igase.:r..efer:toPublic Works Bulletin #1 fees'ar d: estiinate,sbeet. cubic yards cubic yards ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size.. ❑...Water Only Meter Size ❑ ...Sewer Main Extension Public _ ❑ ...Water Main Extension Public „ Call before you Dig: 1 -800- 424 -5555 ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line If WO# WO# WO# Private Private ❑ .. Highline ❑ ...Renton ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ .. Maintenance Agreement(s) ❑...Hold Harmless ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑...Deduct Water Meter Size „ FINANCE INFORMATION Fire Line Size at Property Line ❑ ... Water ❑ ...Sewer Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: City State Zip Day Telephone: City State Zip Page 3 Sr13Y11y� t' Y�rv7.Pa'6. .X:ti Unit Type:..,,: .Qty •.Unit : Type: `:.... Qty . Unit Type: : .. Qty : ,Boiler/Compressor:: Qty. Furnace <I00K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm/Ind t Y6)7 j ai. ti �i:- yi'�.`;jl•.!ia {:�Ct•.�'•i: Contact Person: E -Mail Address: Use: Residential: Commercial: Fuel Type: Electric AT Ot,13A1 t`fi tl - . Y :: �'�.�vg ° Indicate type of mechanical work being installed and the quantity below: MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): New ....0 Replacement .... ❑ New .... ❑ Replacement .... 0 Gas ....fl Other: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STAJE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR HORIZED AGENT: Signature: Print Name: Mailing Address: '20 We rn,, Date Application Accepted: // - 1 .0 -0 3 tapplicationalpermit application (3.2003) 3/2003 EKfl7/ F ri - Date Application Expires: ,s = /D Page 4 Date: ( 7 -d3 Day Telephone :( 2 j ' Z S ✓ 1 — 4 v y zoo Ever4t WA-; ? 7g2e) 1 City State Staff Initials: S Project: S Type of Inspection: , N vv. Address: k?--TO a 7 - Date Called: 8 - 0 2 1 Special Instructions: Date Wanted: m; Requester: Phone No: l S INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector: INSPECTION RECORD Retain a copy with permit R ce 4 6,\Ar. PER (206) 31 -3670 Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: ",e v vvN i 4- C w\ DLQ- l JtL n 1 ✓•trot Date: 8 3 \ _ QL.) El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: S Type of Inspection: 0 w Address 12500 T 16 Date Called: J2?_/oL/ Special Instructions: , 1 WALL k) Date Wanted: a.m. / 2./1/ p.m. Requester 6 �� S a 7 Phone Nd: r -10- - 7 5 2.— � INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: /2,310 y P.o sc 6/7-yot( (Art -2:2 -c-LAtJ o ptdv., 9,124ny 64,0 01 2 crt-t-- lri� i( \fs57;Ab1 Inspector: 6 \l Date: 5q 2 —V6 O $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cal to,schedule reinspection. Receipt No.: Date: A Project: Type of Inspectio Address: Date ailed: Special Instructions: Date lilanted: --- • P • Requester: Phone No: INSPECTION O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit 206)431 -3670 Corrections required prior to approval. COMMENTS: 600/9 -/;,-17k ..- t{..5 "v:':. ?i;�'.'. .. . ✓vnY li lv4c�,(� 71.-0 Li S47.00 REINSPECT' $ N FEE REQUIRED. Prior to inspection, fee must .6e paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: �q;eGt: Type of Inspei VI) Q ( Al Adces_ _.j f Date Called: 7 570 q ----- Sdecial Instructions: Date Wanted 1 7 - a.m. Requeste �� ,`y+) Phone No: 3 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 y Approved per applicable codes. Corrections required prior to approval. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Date: f . $47. 1=INSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 1 Project: /) /744,c) Type of Inspection: // / �//���, Address: Date Called: Special Instructions: Date Wanted: // Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 1 6)431 -3670 fg A s pproved per applicable codes. El Corrections required prior to approval. COMMENTS: Date: El $47REINSPECTION EE REQUITED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: PCaj@ctj r �� I N Type of Inspe ion: • — Addr ss: 1 a Date Called. f Special Instructions: P Dat Wanted: 41) ,/ m. Request U A i t 'AP L 1 • Phone No: n( -- -tgs i %r INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT (206)431 -3670 pproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector Date: ''- 1 S - 40 2- 1 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Z RECEIPT ,_W Ce Parcel No.: 7340600602 Permit Number: D03-349 6 Address: 12500 TUKWILA INTERNATIONAL BL TUKW Status: APPROVED co 0 Suite No: Applied Date: 11/10/2003 w = Applicant: DHS BUILDING - WALL 'N' Issue Date: ...1 LL W ga s Receipt No.: R03 -01579 Payment Amount: 408.75 U- co Initials: SKS Payment Date: 12/31/2003 01:47 PM ▪ W User ID: 1165 Balance: $0.00 ? 1-0 Z 1- W uj 0 O N ca t` . W H • U Type Method Description Amount u_1— Payment Check 91104 408.75 U N — I O H Payee: TRANSACTION LIST: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 SABEY PROPERTIES LLC BUILDING - NONRES PW PERMIT /INSPECTION FEE STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/342.400 000/386.904 363.25 41.00 4.50 Total: 408.75 6137 12/31 1716 TOTAL 6151.39 Printed: 12 -31 -2003 Z Parcel No.: Address: Suite No: Applicant: Receipt No.: R03 -01568 Initials: LAW User ID: 1630 Payee: TRANSACTION LIST: Type Method Description Payment Check 91010 ACCOUNT ITEM LIST: Description doc: Receipt SABEY PROPERTIES LLC PW BASE APPLICATION FEE PW PLAN REVIEW City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 000/322.100 000/345.830 RECEIPT 7340600602 Permit Number: 12500 TUKWILA INTERNATIONAL BL TUKW Status: Applied Date: DHS BUILDING - WALL 'N' Issue Date: Account Code Payment Amount: Payment Date: Balance: Amount 291.00 Current Pmts 250.00 41.00 Total: 291.00 D03 -349 PENDING 11/10/2003 291.00 0 %3 12/30 9716 TOTAL 3309.00 12/29/2003 03:35 PM $408.75 76g Printed: 12 -29 -2003 Parcel No.: Address: Suite No: Applicant: Receipt No.: R03 -01358 Initials: SKS User ID: 1165 Payee: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT 7340600602 12500 TUKWILA INTERNATIONAL BL TUKW DHS BUILDING SABEY PROPERTIES LLC TRANSACTION LIST: Type Method Description Payment Check 90271 PLAN CHECK - NONRES Account Code 000/345.830 Permit Number: Status: Applied Date: Issue Date: D03 -349 PENDING 11/10/2003 Payment Amount: 236.11 Payment Date: 11/10/2003 03:22 PM Balance: $367.75 Amount 236.11 Current Pmts 236.11 Total: 236.11 4579 :UM / ." 97 6 TOTAL 436240 O0 Printed: 11 -10 -2003 MODULAR BLOCK WALL DESIGN INS SEATTLE DISTRICT OFFICE TUKWILA INTERNATIONAL BOULEVARD TUKWILA, WASHINGTON FII.E.�COP E- 2579 -44 February 26, 2003 PREPARED FOR SABEY CORPORATION Earth Consultants, Inc. 1805 - 136th Place Northeast, Suite 201 Bellevue, Washington 98005 (425) 643 -3780 Toll Free 1- 888 - 739 -6670 RECEIVED rI7Y n� TI IKNWHI A NOV 1 0 2003 PEKMII (; N r Ji okil OF TtLA AppR4 VtD DEC 3 0 Z0Q3 AS NUCED U1LOING p1� iM? TD5 0 ,a..u..vc::u..r°:.u:.,,.a .,�.� ..mss• s .. . ,.......... w. ,:.uS:.s.,scStiYr; �.... z re d J U O 0 co 0 w z J I- N lJ., w0 2 L a' = d Z = zo w w co 0 ❑ I-- wW LL. O I ..z z Subject: Earth Consultants, Inc. Geninclinical I;I;II1('(i- ,.(i(Y)I(1).'i is&I:I1virlI 1(p Sci(iniisis (2,It,trtI(li(nt t(:SIiny;h ICI tc): \%'. \I3<)II'.Ix'clitlServices Sabey Corporation 12201 Tukwila International Boulevard Fourth Floor Seattle, Washington 98168 -5121 Attention: Mr. Ralph Hagler Dear Mr. Hagler: Modular Block Wall Design INS Seattle District Office Tukwila International Boulevard Tukwila, Washington MSE and Modular Block Wall Design Established 1975 February 26, 2003 E- 2579 -44 In accordance with your request, Earth Consultants, Inc. (ECI) has prepared this modular block wall design for the proposed site development. We understand mechanically stabilized earth (MSE) fills and modular block wall construction is being considered throughout portions of the site. The modular block wall heights and MSE fills could be on the order of ten (10) to twenty -six (26) feet in some areas. Our scope of services included review of the grading plan prepared by David Evans and Associates, engineering analysis, and preparation of the attached drawing. This design includes the attached drawings with recommendations for construction of the MSE walls, as well as recommendations for seven and one half foot and ten foot high gravity walls. The design calculations for the MSE Wall and gravity modular block walls are included in Appendix A. The reinforcement schedule and recommendations for the wall construction are presented on the attached sheets SM1 and SM2. The soil parameters used in the design assume the reinforced fill soils will be compacted to the specified relative compaction of 90 percent of the maximum dry density as determined by the Modified Proctor Method (ASTM D- 1557 -91). The wall design assumes drainage is provided, and that hydrostatic pressures will not be allowed to mobilize. Additional drainage other than what is shown on the drawings may be necessary, depending on soil and groundwater conditions observed at the time of construction. The drainage shown on the drawings is a minimum requirement. The installation of sheet drain may be necessary along the contact between native cut and the reinforced fill zone, if groundwater seepage conditions are encountered. ECI should observe the MSE and modular block wall construction on a full -time basis. Supplement recommendations for drainage will be made by ECI, if necessary. 1805 136th Place N.E., Suite 201, Bellevue, WA 98005 Bellevue (425) 643 -3780 FAX (425) 746 -0860 Toll Free (888) 739 -6670 Sabey Corporation February 26, 2003 For the MSE and modular block wall construction, a traffic surcharge of two hundred fifty (250) pounds per square foot (psf) was assumed. The design should be reevaluated by ECI for other surcharge loading conditions, where applicable. For the gravity walls, traffic surcharge loading was not included, assuming that the gravity walls will be constructed above the driveway areas or in the vicinity of the storm water detention pond. If the surcharge loading will apply to the gravity walls, ECI should reevaluate the design. Global stability of the proposed walls and fill areas was assessed in the geotechnical engineering study prepared by ECI (see Geotechnical Engineering Study E- 2579 -44, dated February 20, 2003). Global stability was assessed for both static and seismic loading. Adequate factors -of- safety were calculated for the static and seismic loading. We trust this design meets your current needs, and the submittal requirements. If you have any questions or need additional information, please contact us. Sincerely, EARTH CONSULTANTS, INC. EXPIRS5 7 Z-e-i/ 200 Raymond A. Coglas, P.E. Project Manager RAC /KRC /csm Attachments: Appendix A - Calculations Sheets SM1 and SM2 Earth Consultants, Inc, Kyle R. Campbell, P.E. Principal E- 2579 -44 Page 2 r L 2 z. re J U : 0 N C W W I : H N U- W O . D u. a co I a • W APPENDIX A z � o CALCULATIONS w • w n o E- 2579 -44 0 CI W • W I— V, 1 1 1 Z Cr) N Z Earth Consultants, Inc, 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 PROJECT Z7 5' Mode_iw , c.Dc•-11 .14 I. 1. I. • 120S • Is� Earth Consultants Inc. ( oarhnle al I nglne•e•rs. Ge'edogI iIs d I rivlronme•nlal ScIe nIL.ts Q.�...:}is„ . -. _, ..x... , -• -- -. fit .... .. ref • Z..S' S;O 57,5 • c) e O,O • COMPUTED BY C'7 0 1 DATED ^ Z CHECKED BY DATED PROJECT NO. 2S /9 "I Li SHEET ( OF SUBJECT i d L v 6 ...': . } _ �_ 2.?�' L : . . ... r. I ?3D zis ' o ...._ .Z. .o _. } ,, .. ?5 _. _ ' � I lid._ • 1 I M . . 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 I r t Earth Consultants Inc. (Ny l t15nlr.11 litigIneers. Geologists 8. Iim•Ir.,. ni 7uul Scientists PROJECT CI4 , ' , Z a,e-4 l.Qto I 565 .0! s, Z,•S'� 1 152 izES- lobo 1Zg 1s6.5" 232.6 2 6 Z,i 6o , 1 -- °A..) 4 • 1 COMPUTED BY DATED CHECKED BY DATED PROJECT NO. 757 1 ..1 SHEET _- OF SUBJECT 6 ' Q. :: 40e r i \3 1_ GE-II C.a �.. sYir...i'VA V 4iit WuW VLi.L::A5.41,1.:1A. 2 3 4 5 8 7 8 9 10 11 12 13 14 15 18 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 PROJECT • Earth Consultants Inc. Groe('I1nllal Ifi>;Inet•rs. G(l)Ioglsls & L'nvinnunt•nwl ticlrNkts 9 C-k Y r SLth v , Pe V �J1'1-1'cc�� L c,1 < L 12 54, 2'7, s x.11 • 3, o c o *- 1/ CL.X.x-st- 1 l • t f I I i ! 1 • ' s 1 I I ! i ' I ., I (231 COMPUTED BY DATED CHECKED BY DATED PROJECT NO 2 S - N SHEET OF I SUBJECT • \ c i 7 • 1LS i r • r ! • cz— • 2 3 5 - Getme•ehnlevl Engineers. Ge•nk)glsis E. Environmental ScleniKis PROJECT NO 2 LI 4 SHEET OF PROJECT SUBJECT Earth Consultants Inc. COMPUTED BY DATED CHECKED BY DATED Z = L • rew.. ..w.," «.n.r.w. a,. •. a .1,.. vAn.. N ..,. ...y.• �.�.. .. �. ;KH i t t j .... s......•. a.. ....n....,. u.. ....r ;:,. ..r.. ,,, ✓• ,, .r. , •.w.«. .a , . , :..c,,..nm,,. , a.ng ..... v ..,. ....... a.,• +•o „j.. ,n.,. .1. , ...:. ,nnovy... •,,.+., ■ .�.: .. i.. -.. .. _ _ _ ' J 1 1 i k 't 4 r 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Earth Consultants Inc. Cnvterinritatf Engineers. Geologists h Environmental Scientists PROJECT \- P� .. � Sc�cc � �� �cx � G.:. W I ∎3, \zz 1, 6 5D 1 7sa Z Z S II J 7 - 77 1 5 7S Ll �Go Zo e,c110 1 LI co 1- 13, 17,S 4,, $2.2. 1 275 33 z 1 O 2.4,309 �Z,s ,4.E Eb• 2-c 1 ° 2 . ,2 a 7 I P 7.5 1 2 5 3 �?.�i CJ 5 T7 I t c O l ` c ( r Wes' \ +c. *� COMPUTED BY DATED CHECKED BY DATED PROJECT NO. Z -S79 - 4 4 SHEET - OF t SUBJECT s 07 26 CIS 2y I ct • 1 i .. ... i I fi t ' 'ai.t is;; 1 • : � l;�A ,i'.f':.t. _.'rJ I..,:..(vt...0 ,, ,+,V t. l' N• rii. Aw ui • x. .• 0 .'.<... M •i .•.r.+ +AnW4.r. n_ :.frn ^N.,,• 4,., .. ..-. 4..•..' ` r#. u :,..,:.•,, r ! y i a 1 . i } 1 1 Y s I 1 I • { t A 2 t J ■ ! .. I .. 1 g t 11 .z.S i 9 U g 7 z • r f + ,.•.., I ' ' 3. ; r I S I t I J i 1 w•- ,, .N,a. . . , ....,5 - n.w. x .wep...•.gw .a,,.,ru.41•0; .•.h.my w+lL01 n. w. . u... r,+.. a. :t :,n..s+... •I x.r.....,,�e..•.. . 4 . 110 .r.r::•«L.e. .:•,,. ....,.. ....•. • L••.•• •••• ;',:.•• X i 2.2 1 e) 2,, I 2A 4' 1 1 1 2,3 ' Z Z 7 12. 2- I 0 2,. • i 1 Earth Consultants Inc. GIYwc (Iu lliil lifgincrrs. Ge loypsls & Iimlronnw•nlnl Sclenlisls PROJECT • CAC, Se..`•st4 � , -1 rL AMc9e,( > ") = o - 4c.9,b7 Use_ 0. 2So J PtF ,F'Fc a C 4_I c44 () 0 411 5 - //1 -0 . 3 o c l ec --1s- ° i oec^ `c- scpCCe - CD ' o • \ 19 :4 • (2,'7.5 > - � ..S.s gl PRA_ o . 3 7 5 - : 0 .1 0 sor • _ .. r .. . y 4 j.... r i. e j i ,1 Z w Il COMPUTED BY DATED CHECKED BY DATED PROJECT NO.2 7q-4 L. SHEET G ) OF I t SUBJECT •5 , �s ' • :. 1c ::•:T::.w+.Y�F..t�i::.ilii.{..; LiW N�:'.:: r'.'.. tdJ.. S'.. tc�5n11.. 1•A'.i..+:r:.'a.�S�Si<ni�(.�wr. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Earth Consultants Inc. G(4)u m iuik. it Gnginrc•rs. (trologisls & Iinvirun till Sdenllslti PROJECT 1 I • COMPUTED BY DATED CHECKED BY DATED PROJECT NO Z 'S�`l - � L 'I SHEET OF SUBJECT • 4 • r iwrr i .7r1 ,:.4i ?:i;Y.(s.,111.w4,:r sip:y ;;„W3sUu444rr .x;r+lta::+ +.�xaftitiF .;ucl il.+w. s s i ;: Si: iy',iid.t ,S.l�,.. 14 5 „e,S` Earth Consultants Inc. Cvolvchnical ISnglnr ers. <. trloplsls & 13rvirun mill Sclenlisls PROJECT o CL cap « -1. 41u ; Op, FS I j i f i 3 ! i - - al,(? f, L 1 =11 kp = 1(o 1 4. '.' 9• «4. 1 ) 0 12.S • 137S' i- IS,31y 12, S - 5,743• )4,s y e G , ( 0 2 1 \6 - i , . •.r. ,..- .r......a,.w:r.....jrr.:.r, « ... . rr «A . . i„ .,r �.r. r+.•... �; ..,..x COMPUTED BY DATED CHECKED BY DATED PROJECT NO. 9 SHEET OF J,! SUBJECT gl,(off // - , J i .1 • nU« .:i.`['. 44..". }.i.u•J:_ i,f.� "` i.«ioLe.t,`i3a.$ &ii+3�:;�Yl' ••. � ik7: :7Aa:,lik''s'::si�.c�ii..n'w.li i.YrJHC' r.tSsr:L.L r 157S' 00 Earth Consultants Inc. (tottleclutk•alt <knk»41s1s & Iiti nI Sch•nlisth 'ROJECT C V CD4-‘cc- (-1,Sf 2)100 cxi1:3 12,6 (0 2 I os0 Lissc e."6 s164 1 1 74 2.0 2s , • . .t : 4 • +4 r • ; 4 . • i i • r. I • : i r e , I 2s-Z 1 -t I 47 • 0 I 2.5 y e=g2egglaffttoolottewb04~titgalltotti~494401~ 0 001= 01 11 0ii=r-,--.---...— COMPUTED BY DATED CHECKED BY DATED PROJECT NO. 1-51-111 1 SHEET \ OF SUBJECT 3G7 2 \ . , . () :CA (,075m, 1c05514 i I I-1 174 I c J •) ,_*;,),) 16 ,s 7, 1 3= Lic I zcile z 1.5 - ( ‘2- .G 19545-cv 2.1-1)7 B 1L1S4S e" I k 1 114c° 1. a )�a GL4 1 1. Z.. • j • 5 ( t•TRY>lief, t j‘ CS-st;,(c. VS0T I I L o. 10 e 2 3 4 5 43 44 45 lass' A • t Earth Consultants Inc. Qrotttilntl <�tl lingintt•rs. Geologists & IEnvinrunentnl Scientists PROJECT SUBJECT • c-k • c cu- Aotc41 c.r - =t4ex- t,...( '14e - mac. ice 4D .5 Aevi i4 , (Lt s' ` /z.) ( N • � c) .3,e5 ,e 2.. Cis a l.-ki Le:(a. ott, 2:S I 7 Co 1 77 .7,:. ` .• I.5 ..� lD . . t , 12. s fel 1 o • COMPUTED BY DATED CHECKED BY DATED PROJECT NO 2. - 1 4 SHEET I O OF t X3 3 7 : 2A tal !MIMCNYNI(•lJK{.'cIC!•l tt) r G.: • PROJECT Earth Consultants Inc. (R•oter:hi en! Engineers. Geologists & E: vI;ornnrnlal Scientists yi-cgcgc. COMPUTED BY DATED CHECKED BY DATED PROJECT NO 2S H SHEET , \ \ , OF 11 SUBJECT 3 ,7 1 2��s ° �� \G.Ic...S�OC1S ... .�.......1. .. .i. .. ` .... -..'.. ... �._....1 1 .... 1 t ' ,itt!t , 1.z< -3s„ k ! j i i + I tt I I ( i i i d ! 1 I 'M'rr .awv'• F I I ti 71 i ..T._.... 1 } .._._ r) .._ .H ... � .,._. I f .._.N "...nit...". mj4 I i 1 , { p I 1 Gravity Wall Calculations 7.5 Foot Wall Project Description: INS Building EGI Job No. E- X579 -44 February 26, 2003 Wall height will be 7.5 feet maximum Grade above wall will level The blocks will consist of Lock - Blocks manufactured by "Ultra - block" which have typical dimensions of 2.5 feet high, 2.5 feet wide, and 5.0 feet long Soil Conditions: Wall backfill will consist of native and imported silty SAND with gravel Soil in front of wall will be native soil The area below wall will be level Lock -Block Wall Dimensions Height of wall -- 7.5 feet (three blocks high) H : =7.5 Wall batter measured from vertical -- wall vertical, no batter a : = 0•deg Wall embedment H emb : =2 Exposed vertical wall height H := Hw•cos(a)— Hemb Bottom width of wall B : =S Design wall height H : =H e + H B b•sin(a) Top width of wall B t : =2.5 Inclination of ground slope behind wall measured from horizontal plane a : =0•deg Inclination of back of wall measured clockwise from horizontal plane atan B b— B t - 18.43 °deg 0 : =90 +a— 18.43 0 = 71.57 H H e = 5.5 H= 7.5 1Z . • w U o • LIJ Ill I Wo LL co d = w H =. z � !- 0 z uj 0 — 0 H W W : H � LL. O Z H =. o � Z Determination of Earth Pressures and Surcharge Loading Backfill soil unit weight y : =135 Friction angle of retained soils :=30.deg Inclination of back of wall measured from horizontal plane 0 :=71.57.deg Angle of Backfill to Wall Interface with Soil yr :=- 2.74.deg Wall batter measured from the vertical a : =0•deg Friction between concrete Lock -Block and soil 8 := 28•deg K a : =.33 Resultant of active earth pressure z P K a YH 2 Horizontal Component of P P H := P.cos(90•deg— 0 + 8) Vertical Component of P P P.sin(90•deg— 0 +8) P = 1252.97 P H = 863.6 P v = 907.82 Mass Unit Area x'l y'l Weight Mass Moment Mass Moment Sq. ft ft ft k/ft k- ft/lin foot k- ft/lin foot Block 1 12.5 2.5 1.25 1.75 4.375 2.19 Block 2 6.25 1.25 3.75 1.75 4.375 6.56 Block 3 6.25 1.25 6.25 0.875 0.9375 5.47 Soil 1 12.5 3.75 5 1.5 5.6 7.5 Total 16.25 5.875 15.2875 21.72 X' 2.60 V 3.70 Evaluation of External Stability Calculate Center of Gravity for Wall by taking moments of all resisting masses about the toe of the wall and then dividing sum of resisting moments by weight of wall in xy planes: Horizontal distance of "O" measured from toe in xy' coordinates x' := 2.60 Vertical distance of "0" measured from toe in xy coordinates y' : =3.70 Weight of wall and soil resisting overturning W := 5875 Horizontal arm of W measured from toe in XY planes a := cos(a)•(x' +y'.tan(a)) a = 2.6 Vertical arm of PH measured from toe In XY planes b '- H - B b•sin(a) 3.34 Horizontal arm of Pv measured from toe in XY planes e : =B b •sin(90•deg - a) 3.34 .3 .tan(90.deg- 0) b =2.25 e = 4.25 z z - w 6 00 co co 21.1 J H N W WO J u- co = 1- W _ Z � 1- O Z1- W uj n o' 0 5 '- Ill W U- O .. Z. U = 0 Z Evaluation of Overturning Stability Resisting Moment M R :=W P Driving Moment Md:=PH Factor of Safety against overturning MR FS := ° M d Seismic Driving Moment M ds := (P H .b) + 1139+ 427 Factor of Safety against overturning MR FS Os M ds M - - 19134.78 M d -- 1939.21 FS o = 9.87 M d = 3505.21 FS os = 5 Evaluation of Sliding Stability Coefficient of friction between well and foundation soil F :=tan(6) Reaction at the base of wall N := W•cos(a) +P +PH•sin(a) z Q Z . K : =350 JU U Sum of forces providing resistance to sliding N w w= F r:= N•F +W•sin(a) +Pv•sin(a) +Kp H F 4306.49 �--, LL ' u O Sum of forces driving the wall in sliding QQ . F d: =P H•cos(a) F d= 863.6 LL Factor of Safety against sliding d F E- w _ FSs: =Fd FSs =4.99 F— O Z F-. w O co Sum of forces driving the wall in sliding Ill F ds :_ (P H•cos(a )) + 1139+ 427 F d = 2429.6 H H .. z ,H = O ff , Z Seismic Factor of Safety against sliding F FS ss = F ds F = 0.53 FS ss = 1.77 Evaluation of Bearing Capacity and Foundation Stability Width of wall footing B B +0.5 Soil unit weight for bearing soil y : = 135 Friction angle of bearing soil :=34.deg Soil cohesion c : = Surcharge q : = y . ( emb+ 0.5) Ultimate Bearing Capacity q := c•N +0.5•y•B fN +q•N Allowable Bearing Capacity q ult q all 3 q = 337.5 Bearing Capacity Factors from table 4.4.7.1A, AASHTO 1.996 N : =42.16 N : =29.44 N : =41.06 q ult = 25179.53 q all = 8393.18 itricity and Bearing Pressures amming moments about the center of the footing base := W.cos(a) + P v .cos(a) + P H•sin(a ) v := N•cos(a) H := N•sin(a) ,rizontal distance of normal force from toe W.a+ P •e- P H .b := X= 2.54 No NH•tan(a) :centricity of the base reaction from the center of base of wall measured mg the plane parallel to the base of the wall x; Bb X e= - 0.04 2 . cos(a) t b — = 1.67 3. cos(a) B b < and B b- X 5 b 3 cos(a) cos(a) 3 1.6752.54 and 2.4653.33 aximum bearing pressure N 6.e x g max : = 1 Bb + Bb nimum bearing pressure N 6.e x ) q min :_— 1 - B b Bb X X 2.B b -254 Bb- -246 -333 cos(a) 3 q max = 1299.32 q min = 1413.81 N = 6782.82 N v = 6782.82 NH= 0 Project Description: INS Building ECI Job No. E- 2579 -44 ' February 2S, 2003 Wall height will be 10.0 feet maximum Grade above wall will be level The blocks will consist of Lock - Blocks manufactured by "Ultra- block" which have typical dimensions of 2.5 feet high, 2.5 feet wide, and 5.0 feet long Soil Conditions: Gravity Wall Calculations 10.0 Foot Wall Wall backfill will consist of native and imported silty SAND with gravel Soil in front of wall will be native soil The area below wall will be level Lock -Block Wall Dimensions Height of wall - -10 feet (four blocks high) H =10.0 Wall batter measured from vertical -- wall vertical, no batter a : =0•deg Wall embedment Hemb : =1 Exposed vertical wall height H := Hw.cos(a)— Hemb Bottom width of wall Bb: =S Design wall height H:= He+Hemb +B b•sin(a) Top width of wall B t Inclination of ground slope behind wall measured from horizontal plane I3. =0.deg Inclination of back of wall measured clockwise from horizontal plane atan B b — B t - 14.04 adeg 0 :=90+ a — 14.04 0 = 75.96 H H e = 8.5 H= 10 Determination of Earth Pressures and Surcharge Loading Backflll soil unit weight y: = 135 Friction angle of retained soils i := 30•deg Inclination of back of wail measured from horizontal plane 0 := 75.96-deg Angle of Backflll to Wall Interface with Soil yr := - 2.74-deg Wall batter measured from the vertical a : =0•deg Friction between concrete Lock -Block and soil S := 28•deg K =0 Resultant of active earth pressure 2 P: = KayH P= 2227.5 2 Horizontal Component of P PH:= P•cos(90•deg— 0 +8) PH= 1654.31 Vertical Component of P P P•sin(90•deg -0 +S) P 1491.64 Mass Unit Area x'I VI Weight Mass Moment x' Mass Moment y' Sq. ft ft ft k/ft k- ft/lin foot k -ft/lin foot Block 1 12.5 2.5 1.25 1.75 4.375 2.19 Block 2 12.5 2.5 3.75 1.75 4.375 6.56 Block 3 6.25 1.25 6.25 0.875 1.09 5.47 Block 4 6.25 1.25 8.75 0.875 1.09 7.66 Sall 12.5 3.75 7.5 1.562 5.8575 11.71 Total 27.5 6.75 16.7875 33.59 x' 2.49 y' 4.97 a Evaluation of External Stability Calculate Center of Gravity for Wall by taking moments of all resisting masses about the toe of the wall and then dividing sum of resisting moments by weight of wall in xy' planes: Horizontal distance of "0 measured from toe in xy coordinates x' : = 2.49 Vertical distance of "0 measured from toe In x'y' coordinates y' := 4.97 Weight of wall and soil resisting overturning W := 6750 Horizontal arm of W measured from toe In XY planes a := cos(a)•(x'-t- y'•tan(a)) a= 2.49 Vertical arm of PH measured from toe In XY planes b := H B b•sin(a) b = 2.99 3.34 Horizontal arm of Pv measured from toe in XY planes e :=B b•sin(90•deg- a - H 7.34 •tan(90•deg- 8) e = 4.25 • MR FS o : = - d Seismic M FS os :_ M ds Evaluation of Overturning Stability Resisting Moment M := W•a +P Driving Moment M d : =PH•b Factor of Safety against overturning Driving Moment M ds :_ (P H •b) + 2025+ 750 Factor of Safety against overturning M 23148.91 M d = 4953.04 FS = 4.67 M d = 7728.04 FS os = 3 Evaluation of Sliding Stability Coefficient of friction between wall and foundation soil F :=tan(6) Reaction at the base of wall N := W•cos(a) + P v •cos(a) + P H•sin(a) K : =350 Sum of forces providing resistance to sliding F r : =N•F+ W•sin(a) +P vsin(a)+ K p•Hemb Sum of forces driving the wall in sliding F d : =P H•cos(a) Factor of Safety against sliding F FS s := Fd Seismic Sum of forces driving the wall in sliding F d :_ ( P H •cos(a )) + 2025+ 750 Factor of Safety against sliding F FS ss : _ F ds F = 0.53 F r = 4907.16 F d = 1654.31 FS =2.97 Fd = 4429.31 FS ss = 1.11 • Evaluation of Bearing Capacity and Foundation Stability Width of wall footing B f:= B -F0.5 • Soil unit weight for bearing soil y : =135 Friction angle of bearing soil :=34.deg Soil cohesion c : =0 Surcharge q : = y' (H emb+ 0.5) q = 270 Bearing Capacity Factors from table 4.4.7.1A, AASHTO 1996 N =42.16 N : =29.44 N Y : =41.06 Ultimate Bearing Capacity q ult := c•Nc +0.5•y•B f +q•N Allowable Bearing Capacity q ult gall 3 q ult = 23192.33 q all = 7730.78 Eccentricity and Bearing Pressures Summing moments about the center of the footing base N:= W•cos(a)- }- Pv•cos(a) +PH•sin(a) N = 8241.64 N := Ncos(a) N 8241.64 NH;= N•sin(a) NH- 0 Horizontal distance of normal force from toe Wa +Pve- PH•b X := N�+ NH•tan(a) Eccentricity of the base reaction from the center of base of wall measured along the plane parallel to the base of the wall e = B b X x - 2 cos(a) B = 1.67 3 Bb d _ 3 cos(a) 1.6751.95 X - 2.21 cos(a) Maximum bearing pressure N 6.e q : = —• 1+ B b B b Minimum bearing pressure N 6 -e x g min '_ —• 1 - B B X B b - - 2.79 cos(a) and B b 5 - b cos(a) 3 and 3.0553.33 q max = 2226.31 g min = 1070.35 e =0.29 X-= 2.21 2•B b -333 3 June 17, 2004 City of Tukwila Department of Community Development Steve Lancaster, Director w tr � i U • u U O J = H W O 2 u . i �W Z = t I- O W E-. • W O N. O I- lia W • U This inspection is intended to determine if substantial work has been accomplished since issuance of the permit 16 p or last inspection; or if the project should be considered abandoned. W Z UN If such determination is made, the Building Code does allow the Building Official to approve a one -time 0 extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why Z circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to July 13, 2004, your permit will become null and void and any further work on the project will require a new permit and associated fees. Ralph Hagler 12201 Tukwila International Boulevard Tukwila, WA 98168 RE: Permit Application No. D03 -349 12500 Tukwila International Boulevard Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer Permit Technician Xc: Permit File No, D03 -349 Bob Benedicto, Building Official Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206-431-3665 • '..r. ru.r ,wax: December 1, 2003 Ralph Hagler 12201 Tukwila International Blvd Tukwila, WA 98168 -5121 Dear Ralph: If you have any questions, please contact me at (206) 433 -7165. Sincerely, Stefania Spencer Permit Technician encl xc: File No. D03 -345 File No. D03 -346 File No. D03 -347 File No. D03 -348 File No. D03 -349 File No. D03 -350 File No. D03 -351 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: CORRECTION LETTER #1 Development Permit Application Numbers D03 -345 - Wall L, D03 -346 — Wall M, D03 -347 - Wall Ml, D03 -348 — Wall M2, D03 -349 — Wall N, D03 -350 — Wall R and D03-351 — Wall P DHS Building —12500 Tukwila International Boulevard This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. At this time the Fire, Planning and Building Departments have no comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `revision sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 l,: ati>:t uws: IdaiY,W..w.m+.td..:.4.u!irissrek .. ,�,,, �u,» rua+.tw....i.4w,i.ax+L'+:JL4�u �•,,• :i.:.SL'.i:.�:S� .: ':'1' z = z J U U N 0 -J • u. w 0 g J u. < -± z �' l-0 Z • ~ D O U O N O l- w • w I— a. O .. O 1— z DATE: PROJECT: PERMIT NO: PLAN REVIEWER: . Plan Comments 1) Provide benchmark data on the plan sheet. (P:Laurie Admin/Mike /Comments D03 -345) PUBLIC WORKS DEPARTMENT COMMENTS November 25, 2003 DHS Building - Retaining Walls D03 -345, D03 -346, D03 -347, D03 -348, f D03 -349, D03 -350, D03 -351 Contact Mike Cusick at (206) 433 -2441 if you have any questions regarding the following comments. 2) Provide top of wall elevations on the sections of the wall (not just gridline elevations). 3) Application base fee of $250 plus 2.5% of erosion prevention and storm water due with revision for each permit. Upon issuance of the permit, 2.5% issuance and inspection fee is due for each permit. 4) Minimum footing drain size is 6" for Earth Consultant drawings. ACTIVITY NUMBER: D03 -349 DATE: 12 -12 -03 PROJECT NAME: DHS BUILDING - WALL "N" SITE ADDRESS: 12500 TUKWILA INTERNATIONAL BLVD Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # Revision # after /before permit is issued DEPARTMENTS: Building Division ❑ Fire Prevention ❑ Planning Division ❑ Public W orks 21 � Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -16 -03 Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route [v'( Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01 -13 -04 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28.02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Incomplete ❑ PERMIT COORD COPY Not Applicable ❑ DATE: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D03 -349 PROJECT NAME: DHS BUILDING - WALL "N" DATE: 11 -10 -03 SITE ADDRESS: 12500 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # /before permit is issued DEPARTMENTS: ��nn &C. /1-161 4457 h1 t Build `Division U Fire Prevention d Planning Division Lz, Public Vygrps / , Q Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -13 -03 Complete [d Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R�TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12 -11 -03 E( Approved CI Approved with Conditions ID Not App roved ( attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only / 11.4 " ."0 3 CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PWW Staff Initials: SAS Documents /routing slip.doc 2 -28-02 PERMIT COORD COPY a3h;` Y � ` . ' �� i i ^ .: s xw s w Ls ` rE iSic+:: 4iL .'Y:nu:;r;:w:u�a a.:, 1t/Yb /u.. nrU tt.JO rtiA LW, 601 UU6u attuey uorvuraLion City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /a 7 0 3 Plan Check/Permit Number: D03 - 341 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # / ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: 2-W3 3(//4.0f4 Project Address: / - Ziff Contact Person: 4,6i 1-6, Phone Number: .206 -- o?S! — g70ca Summary of Revision: ,6E✓✓CA01 4DOF) o/ /4604.0 ,e41/4540 774/0 err✓ /*',W. /,r 7 A 7-70-vAL 4I IJ& . -1 42A,WA 9/Y.$72/ ciesb Der c Fk Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by : /S [-r Entered in Permits Plus on (2-1? .4 3 08/06/03 tgj uua • OM WE 11••I NM EN MIN NMI MMMMMMMMMMMMM 1111•11 UN MIN MN =I ON MI MN MS MI MIN MI IIMMI NM EMI NM MN INN 1•• NMI INS MI MI INN II= NE NMI IMP MI 11= I•111 MMMMM MN MI EMI NM UM MI Eli • • • IN MIMI 1110 11= IMO MM MMMMMMM MN MI MI MS INN MN ME =I IMO NM NM 1•• 11.• EN MN INN MMMMM MMMMMMMMMM ! ■ 0 1 • • WALL 'M' 0 110A1111 I 1.1111 II 11111111AILL 1P. I 11. ~ q uit NI IIIIIIIII�IIIIIIIII HIIII■ •'' WALL 'A' GRAVITY WALL I I 1 R+k2O0.00\ L-2721' b•7'52'42' A PORTION OF THE 8E 1/4 OF ME 8E 1/4, SECTION 9 AND A PORTION OF THE 8W 1/4 OF THE 8W 1/4, SECTION 10, ALL IN T. 23 N., R 4 E., W.M. R•202.50' WALL A' *DER SEPARATE PER$ T .....L. WALL 'A' GRAITY WALL EAST ONE — QUARTER QUARTER SECTION 1231.R4E, 11111. TOP OF r PME W/VASS CAP • yE `xz• - -" ��� y PROJECT DATUI•14.46 PROJECT DATU•M NAVO ♦ 0.3S FEET f CITY GF TUKWI,LA APPROVED C 3 0 2003 F- ... —gEEMBINNICIEL 1. CONSTRUCTION SPECRICATIONS ARE PER THE "MODULAR BLOCK WALL DESIGN' REPORT PREPARED BY EARTH CONSULTANTS, PC. FOR THE OHS BUNANrO, 1UKMB,A, WA. DATED FEB 26, 2003. SHEETS 211 AND SY2 CONTAIN SPECIFICATIONS, SCHEDULES AND VARIOUS DETAILS. NG S it, .: if A gg F ' _ f " rr 1 . ' p � �S I�'d''.�, UT � 1 ._1.':. ' .: EfL . :"!,g WILL RE A � N �< . A:') NAY •IC.L ADO N.* � . �8► i lay :fie. plans t. Department for cnrformarc standards. Acceptance is snl'icct to errors. an missions Tfi ttryito tat ,nthorixc violations of adopted standards or ordinances. ctr s rr the adequacy of the design rats totally - i11 , } q designer. Additions, deletions or revisions to these dry,« inks. after this date will void this acccrt:;'cc ; -nd will require a res:-.hriitT.il of revised Ornvings for sl :hsc :1cn1 3'_CC� j tnraa. t r T''ii'C 1 • C ..».1 CCt t( f.c' . 1'. 'CCT'nr. 1 t J lT :il tl;r P :�lic t1? � . t ic% irsrci? 1 `. i 2 `t l c - 7 • S Panel No. FILE ca : �`'.. ______ NIB _ w,■__.■_ ____ ale __111.__._.r_ MIN _ MIN ......................... i WALL 1: ! ._ a0 N c=> RTH 0 1S SO SD I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- s copy of approved plans acknowledged. / 7 eF1‘01 DE 1 12 2003 Q DAVID EVANS woo ASSOCIATE= ono. 1620 W. Marine view D,%*, Ste. 200 Everett Washington 00201 Phone: 425.259.4099 A A C H I T I I C T S A I A 130 LAKESIDE • SEATTLE, WA 9122 • 206 325 2553 i NUGSICSIMISEER 0 C 0 ' WV* 12.50' 15.00 — TOP BACK I • u11111 'i III I umummoim mom I ilia 111111111111111111111111WIN1UM111111101 1111111111111111111111111111115411111UMM1 11111111111111111111111 10.1145 MIMI Mill Mil 11111111111111111 VI IIIIIINNAR 41 911111111 MISE IU NIA MI 5.00' 40 0+00 • 87.50' 0+50 0+00 100 MMOOMMOOMMEMOMMOMOMMOMMEM ,AIJIMIIMMINNIMOMPAIMMIRWEIMINNIPANOWINIAIMINIONNIL Ill I N 1111111 & 111E11111111111111111111111516:22MLIPMININIMMIll __ Ihrilbsommi I „gag" , 11111110ian _EWA .11111111111111111111111111111111111111111111111111111111111111111111111011111111hiiiiiiiialMZEHEIMIIIMMINININEME OblErliniellill i 1 1 NNEraiiiilLI •EBLJILIIIIIIIIIIJMIIIIIIJIIIIIIIIIIIIIIIIINIMIIIIIIIIIIIUIMUIIIIIIIIIIMIMIMMNINMIIMMIIIIIIIIIIIIIIIIIIIIIIIIIIMIMiliiiiiiiiiitinCIES1CLIE;IMIPIIIIIIIIIIIIII , 11111111111 WALL ASA 11,406 , MillriliIllihlillibsmsii6NIIIIIMMPNIIMFIMIMNNIIIBWIIIIIIIIIIIJIMIMMIIIIIIIIIIIIIIIIIIIMMEIIBIMIMIUIMIIIIMIIII,f.IIMIIIIIIIIMIJMMliiSEI I I llingallalliniodilININIIIIIIIIIIIIIININIUMIIIIIN1111111111111111111111M1111=111111011111111111111111111 111111111111111111011111111•1111 _ . __ . pp A 1111111111011111111011111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 1111111111111111111111111111111111111111 IM IUMNIMENEMP I , IPMEII 11101011111111111111111111111MSTIMII111.1011111111111111111111111111111111111111111111111111111111111111111EHINI1911111111 iiiiIMICZNEN11111111 iiirommIll111111111111111111111111111111111111111111111M11111/21111111119611.1 ! , 111111111110111111111111111111111111111111111111111111M1111211 i ! NINO 111101111.E.M111111111111111111111111111111P51111 111111111fil i 1 Min Mi11111111111111111151111 111005111111111111211111 111111111: Mill APPROX GRADE AT FACE OF WALL WALL AFEA 1 - -60 • - : • • MIN DEPTH OF RAU. BELOW GRADE 111.1111tramon 11111111111•11111111111,1 M1111111111111VAII 11 1111•11111111151 1 111111111111111111101 liii 111111/11111 511111111111111111 11011111111111rra wommiemIl M f: ain a I1EV.117.5 122■043.0 0+50 40.00 1+00 1023 - r 8196 APPROX GRADE AT FACE OF WALL 1 CD 3.98 40 - 0 9 V 1+50 1+00 L465 ptiiwlib. W AL 'N' FITIOFILE SCALE:1 HOR2 1 1..10' VERT i I I ■ 1 i i 1 0+00 0+50 2+00 285.00' mei DIEPTH OF WALL 13ELOW GRADE STEPS TO UPPER SIOEWALK INFRONT OF WALL 1+50 ALL LAMA W SF • J 2+50 - -r 3+00 397.50' -GRADE-AT TOP CX OF WAULm47.5 0+00 10.0' ' • ' ■ • i raw.mt 11011.114011. i INIMUNIIMMINEINNIII misionmsesammiummamoromm = wpm m immommummums immommommu ism IIMMESSOINOMIN111111111:11111111111111111111 NOIMMMIN I 1011111111111E1111111111 111111111111110111111 IIMEHOmmiiiiiii=IMUSESAININIMMININIIIIIIIIIIIIIIM momsammummommoommismanommilissouv= 3+50 'M PROF:)_ SCALE:130' HORZ 1 VERT 2+00 2+50 3+00 .--, ZS:. -- T 7 r _ I __ _ 7 UNIIIII . ! . , i . IIIIIIONSLINIIII HIIIIIIIIIIIIIMENOMII 111110111111111111111111111111112EFININI IIIIIIIIINIMEN111111111111111111111111111M111 11111111111111111111111111111111111111111111111111111111111111151111 111111111111111111110111111111111111111112M1111 . \ ,, >, , mmmemmummumemmermiummommummememinummummom ' . aro.xto , OilliMmummommilarammammummumummummiiimmumnimm , mosimmummomigaim summommummummommumunial ! , , ! WALL AREA 5825 SF . diallingenniniiiii691111111 APPROX GRADE AT ; I : FACE OF WAU. I . 670.00 4+00 3+50 • 1414 DEPTH OF WiLL WI OW GRADE 4+50 4+00 5+00 4+50 c lii;Th411.0 375.00' 5+50 .GRADE AT TOP BACK OF WALL 41E;;77 C 5+00 37.50 • V ; ! 2401 100 W4L. APF4 5004 SO i -- _L.,;_ _ ! (00-974 riall WOWS ' 'r „largammusesimmommommummum slimm • ' 11111011111111111 MINIINIMMOdiiiiii1012991NOMONINI . 1211111111111111111111111111111111111111101111111111111111 =mu , BEIM W/4.L 1 i ! EUEV,47 umplimplommilmommoommommummomong Ammoommaimmliprimprommonomm millimilmillip Immulau -11111mommillgepli. _AllmommommEMMIIIINO 80 APPROX GRADE AT 1111111111,111 E . 1 101110Wail WALL 'P' MALE : FAcEoF •ALL i ' am MN OEM OF WALL i t , ' : SCALE:1**30* HORZ 1 I BEI.OW GRADE A ___ 1 J. i i 1'240' VERT ' 1 1 : 0+50 1+00 1+50 2+00 GRADE AT TOP WALL • • 1199.01 ; 100 80 1 6+00 . 1 . MIN DEPTH OF WALL BELOW GRADE , 5+50 AT i 20240' 6+50 6+00 100 - — eo 60 . es 0+00 - 1 7+00 6+50 7+50 6+56 eo - 160 1+00 8+00 25.31' ace montew *knew eo 60 IMO STEPS, MIND IMO HIM NMI 1+50 8+50 22 375.00 WALL AREA MN SF WELL 'MA' PROFILE SCALE:1"30 HORZ 1 VERT mum DEPT10 Cf WALL MOW GRADE 2+00 21' 9+00 GRADE AT TOP RACK OF WALL • 9+50 2+50 • 10+50 bi)41 25.00' CLOO'j 00' 0 a 3+00 11+00 ION msommumminisimmu mmommomemommilmommomm ossummammumminummus imummassommosinsmomm' nivots 4 4 APPROX GRADt AT - + 1111161"7"111111311 WALL i4FIEA 3344 SF !FACE OF wxy OL ') 35 %tifn +0 Li00/ONG SOUTH; -. 100 80 11+50 60 STEPS BEHIND • 60 37.50' - I - BO so - -40 N441.1. AREA 2406 SO ALL 'L,' SCALEris HOME 1 VERT I 20 DAVID IMAMS Ano ASSOCIATES 1,00. 1620 W. Wine View Drive, Suits 200 Evora Washingion 96201 Phone: 425.259.4099 A PI C NITRO te • AI^ 130 LAKESIDE • SEATTLE, WA 98122 • 206 325 2553 DEPARTMENT OF HOMELAND SECURITY SEATTLE DETHICT OFRCE 12500 TUKWILA tfTONAL BLVD. SEATTLE, WASHINGTON Geogrid Layer Spacing (Ft.) (Measured From Bottom of Wall) Lock - Block Wall Height (ft.) Geogrid Length (ft.) 1 2 3 4 5 6 7 8 9 10 5.0 6.0 2.5 - - - - - - - - - 7.5 8.0 2.5 5.0 - - - - - - - 1 ■•- vlogiib- �, 10.0 10.0 2.5 5.0 7.5 - - - - - - ,, ci�nc eta 12.5 12.0 2.5 5.0 7.5 10.0 - - - - - y ± r►t - ';`�'tIgs l_i _ (,t ,be �� lc 1 �illr ��,1,�r - 15.0 14.0 2.5 5.0 7.5 10.0 12.5 - 17.5 16.0 2.5 5.0 7.5 10.0 12.5 15.0 - _ 20.0 18.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 - - v'- "A‘ lr: r,,; 22.5 20.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 • 1 25.0 22.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 - 27.5 22.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 SPECIFICATIONS: MODULAR BLOCK AND MSE WALL CONSTRUCTION GENERAL A. Work shall consist of furnishing and construction of a Modular Block and MSE Retaining Wall System in accordance with these specifications and in reasonably close conformity with the lines, grades, and dimensions shown on the plans. B. Work includes preparing foundation soil, furnishing and installing leveling pads, drainage fill and backfill to the lines and grades shown on the construction drawings. C. Work includes furnishing and installing geogrid soil reinforcement of the type, size, location, and lengths designated on the construction drawings and MSE Wall Schedule. SUBMITTALS A. Contractor shall submit a Manufacturers certification, prior to start of work, that the retaining wall system components meet the requirements of this specification and the structure design. B. Contractor shall submit a test report documenting strength of specific modular concrete unit and geogrid reinforcement connection. The maximum design tensile load of the geogrid shall be equal to the laboratory tested ultimate strength of geogrid I facing unit connection at a maximum normal force limited by the "Hinge Height" of the structure divided by a safety factor of 1.5. QUALITY ASSURANCE A. Contractor shall submit certification, prior to start of work, that the retaining wall system (modular concrete units and specific geogrid) has been successfully utlilized on similar projects, i.e., height, soil fill types, erection tolerances, etc. B. Contractor shall demonstrate prior experience on projects of similar size and magnitude where the specific retaining wall system has been constructed successfully. Contact names and telephone numbers shall be listed for each Proiect. C. Owner shall provide soil testing and quality assurance inspection on a full-time basis during earthwork and wall construction operations. Owners quality assurance program does not relieve the contractor of responsibility for wall performance. DELIVERY, STORAGE AND HANDLING A. Contractor shall check all materials upon delivery to assure that the proper type, grade, color, and certification has been received. B. Contractor shall protect all materials from damage due to jobsite conditions and in accordance with manufacturer's recommendations. Damaged materials shall not be incorporated into the work. PRODUCTS DEFINITIONS A. Modular Block: a concrete retaining wall element machine made from portland cement, water, and aggregates. B. Structural Geogrid: a structural element formed by a regular network of integrally connected tensile elements with apertures of sufficient size to allow interlocking with surrounding soil, rock, or earth and function primarily as reinforcement. C. Unit Drainage Fill: drainage aggregate which is placed immediately behind the modular concrete units. D. Reinforced Badkfill: compacted soil which is placed within the reinforced soil volume as outlined on the plans. MODULAR RETAINING WALL UNITS A. Modular Block units shall conform to the following architectural requirements: face color: concrete gray - standard manufacturers color may be specified by the Owner. bond configuration: running with bonds nominally located at midpoint vertically adjacent units, in both straight and curved alignments. B. Modular Block materials shall conform to the requirements of ASTM C1372- Standard Specifications for Segmental Retaining Wall Units. C. Modular Block units shall conform to the following structural and geometric requirements measured in accordance with appropriate references: compressive strength = 3000 psi minimum absorption = 8% maximum (6% in northern states) for standard weight aggregates unit size: 2.5' (H) x 5.0' (W) x 2.5' (D) minimum unit weight: 4,320 lbs. / unit BASE LEVEUNG PAD MATERIAL A. Material shall consist of Drainage Fill (1" Minus Crushed Rock) and placed as shown on the construction drawings. DRAINAGE FlLL A. Unit drainage fill shall consist of clean 1" minus crushed rock meeting the following gradation tested in accordance with ASTM D-422: 1 inch 3/4 inch No. 4 No. 50 P 100 75-100 C -10 0-5 REINFORCED BACKFILL A. Reinforced backfill shall be free of debris and have a moisture content that is at or near the optimum level. B. The maximum aggregate size shall be limited to 1 1/2 inches unless field tests have been performed to evaluate potential strength reductions to the geogrid design due to damage during construction. C. Unsuitable soils for backfill (high plastic clays or organic soils) shall not be used in the backfill or in the reinforced soil mass. D. The fill material shall meet the following gradation: M Percent Passing 1 1/2 inch 100 - 75 3/4 inch 100 - 75 No. 40 0 - 60 No. 200 0 - 35 Fill that does not meet the above gradation must be approved by the geotechnical engineer. GEOGRID SOIL REINFORCEMENT A. Geosynthetic reinforcement shall consist of geogrids manufactured specifically for soil reinforcement applications and shall be manufactured from high tenacity polyester yam or high density polyethylene. Polyester geogrid shall be knitted from high tenacity polyester filament yam with a molecular weight exceeding 25,000 Meg/m and a carboxyl end group values less than 30. Polyester geogrid shall be coated with an impregnated PVC coating that resists peeling, cracking and stripping. B. Geogrid long term design strength shall be at least 4,700 lbs./ft for walls 15.0 feet or higher. For walls 12.5 feet or less, LIDS shall be at least 2,800 lbs./ft. The contractor shall provide manufacturers specifications to the geotechnical engineer for review and approval. C. Manufacturing Quality Control The geogrid manufacturer shall have a manufacturing quality control program that includes QC testing by an independent laboratory. The QC testing shall include: Tensile Strength Testing Melt Flow Index (HOPE) Molecular Weight (Polyester) DRAINAGE PIPE A. The drainage pipe shall be rigid perforated PVC pipe manufactured in accordance with ASTM D -3034. EXECUTION EXCAVATION A. Contractor shall excavate to the lines and grades shown on the construction drawings. The geotechnical engineer shall observe the excavation and approve prior to placement of leveling material or fill soils. Proof roll foundation area as recommended by the geotechnical engineer to determine if remedial work is required. B. Over- excavation and replacement of unsuitable foundation soils and replacement with approved compacted fill will be compensated as agreed upon with the Owner. BASE LEVEUNG PAD A. Leveling pad material shall consist of Drainage Fill, and shall be placed as shown on the construction drawings, to a minimum thickness of 12 inches. B. Soil leveling pad materials shall be compacted to a minimum of 95% Modified Proctor density per ASTM D- 1557 -91. C. Leveling pad shall be prepared to insure full contact to the base surface of the concrete units. MODULAR - BLOCK UNIT INSTALLATION A. First course of Modular Blocks shall be placed on the leveling pad at the appropriate line and grade. Alignment and level shall be checked in all directions and insure that all units are in full contact with the base and properly seated. B. Place the front units side -by- side. Do not leave gaps between adjacent units. Layout of corners and curves shall be in accordance with manufacturers recommendations. C. Place and compact drainage fill behind Modular Block wall units. Place and compact reinforced backfill soil behind drainage fill. Follow wall erection and drainage fill closely with structural badkfill. D. Maximum stacked vertical height of Modular Block wall units, prior to unit drainage fill and backfill placement and compaction, shall not exceed two courses (5 feet). STRUCTURAL GEOGRID INSTALLATION A. The geogrid strength, perpendicular to the wall alignment, shall meet the strength specifications. B. Geogrid reinforcement shall be placed at the strengths, lengths, and elevations shown on the construction design drawings or as directed by the Engineer. C. The geogrid shall be laid horizontally on compacted backfill and attached to the Lock -Block modular wall units. Place the next course of modular concrete units over the geogrid. The geogrid shall be pulled taut, and anchored prior to backfill placement on the geogrid. D. Geogrid reinforcements shall be oontinous throughout their embedment lengths and placed side -by -side to provide 100% coverage at each level. Spliced connections between shorter pieces of geogrid or gaps between acacent pieces of geogrid are not permitted. REINFORCED BACKFILL PLACEMENT A. Reinforced backfill shall be placed, spread, and compacted in such a manner that minimises the development of slack in the geogrid and installation damage. B. Reinforced backfill shall be placed and compacted in lifts not to exceed 6 inches where hand compaction is used, or 10 inches where heavy compaction equipment such as rollers is used. Lift thickness shall be decreased to achieve the required density as required. C. Reinforced backfill shall be compacted to 90% of the maximum density as determined by ASTM D- 1557 -91. The moisture content of the backfill material prior to and during compaction shall be at or near the optimum moisture content. D. Only lightweight hand - operated equipment shall be allowed within 3 feet from the modular concrete unit. E. Tracked construction equipment shall not be operated directly upon the geogrid reinforcement A minimum fill thickness of 6 inches is required prior to operation of tracked vehicles over the geogrid. Tracked vehicle turning should be kept to a minimum to prevent tracks from displacing the fill and damaging the geogrid. F. Rubber tired equipment may pass over geogrid reinforcement at slow speeds, less than 10 MPH. Sudden braking and sharp turning shall be avoided. G At the end of each dad's operation, the Contractor shall slope the last lift of reinforced backfill away from the wall units to direct runoff away from wall face. The Contractor shall not allow surface runoff from adjacent areas to enter the wall construction site. AS -BUILT CONSTRUCTION TOLERANCES A. Vertical alignment: +1.5" over any 10' distance B. Wall Batter. within 2 degrees of design batter C. Horizontal alignment: +1.5" over any 10' distance Corners, bends, curves +1 ft. to theoretical location D. Full contact between blocks shall be maintained. FIELD QUALITY CONTROL A. The wall construction shall be observed by the geotechnical engineer on a full time basis. Testing of the compacted backfill shall be performed by the geotechnical engineer. B. As a minimum, quality assurance shall include foundation soil inspection, soil and backfill testing, verification of design parameters, and observation of construction for general compliance with design drawings and specifications. NOTE: For tiered walls consider the overall effective height of the tiered wall system when determining required geogrid length from the reinforcement schedule. MODULAR BLOCK - MSE WALL : REINFORCEMENT SCHEDULE b!r3 cm of TIOILA APPRoro DEC 3 O ZI13 AS IOUItU BUILDING DIVISION Q C C Co, 1 Ct ry U !E, 7 pidl r e\ ie�� e,1 1,: , the Vu'Olic alt. for 4��t�t with curccfl . .t , e �,ru� tcr5 at+ bul)\c''t to c Aid11211904" '15 ° not The with the ich ordinances. I vr es of rests totally IvAcv of the recisi cliIi 'elct'�`�n` or Dance ; l ,his acceptance c cli;i�r`• hie will vr� CT t�1 rrc,tl'`�1tsa1 of roc tine „i rr lent arrr rn•al. E"icicl irct�'ctto° W.; 1` sit�`��[t t� r. Vance �ct� r C` I it,,l ice it re _____L---- -------------- 2 I U co O V L LU U C au � M C E 2 cA cp to c� ` ya • •8 c o C C � Tri �J Shoot No. SMI d . • • Mar 0 S a Weight • 4,320 bs. Lock -Block At Corner MODULAR BLOCK UNIT DETAIL NOT - TO - SCALE NOT - TO - SCALE VERTCAL WALL - 90 CORNER Battered walls at 90 degree corners are constructed as follows: Stack a vertical column to fill the comer. Adjust toe of battered wall to meet with corners of vertical stack (ie: kick toe out for outside corner, meet toe at edge for inside comer). For walls higher than 7.5', you may use a stack of full-size, interlocked blocks to make a 5'x 5' vertical stack, rather than 2 - 2.5'x 2.5' stack with single half blocks. Use geogrid between the vertical blocks, extending bad( into the fill. Make the corner stack the same width as the wall base (2.5' i 5' / 7.5' etc.). 4.92' etIDEMIEW 4.92' TOP VIEW MODULAR BLOCK WEDGE CORNER DETAIL • w NOT - TO - SCALE ISOMETRIC CORNER VIEW MODULAR BLOCK CORNER OPTIONS NOT - TO - SCALE Modular Block 2.511 x 2.5W x 5.0'L 2H : 1V Slope (.) .w =wa =mmwmm aam =imam mammal mmumuma •wam =mma•m NOTE: Geogrid is to be placed on level bsoldMN and extended over the top and out to the floe of the Lock - Block Units. Plops next row of Bock, pull geogrid taunt, *took es required and baakM. GEOGRID AND LOCK -BLOCK CONNECTION DETAIL NOT TO SCALE Place Ge000nnposito Sheet Drain on face of temporary excavation. Minimum 30% coverage of excavation face. Use Miradrain 6000 or approved equivalent Reinforced Fill Zone Reinforced Fill Zone MODULAR BLOCK MSE WALL SECTION I I I 1 1 I d" Diameter Perforated PVC Drain Pipe, Surround with Minimum 1 cubic Boot of 1' Washed Rock per meal foot of pipe. Gravity flow to approved discharge point. Wrap Washed Rock with Mir fabric Mirali 140N or approved equivalent. 111 111EII1 111E. Modular Book 2.6Hx2.5Wx5L (TyP) 7.5' MODULAR BLOCK GRAVITY WALL NOT - TO - SCALE Modular Block 2.5H x 2.5W x 5L (T-P4 NOT -TO -SCALE Drainage Fill " Minus Crushed Rock Pea Gravel 1 Cubic Foot per Lineal Foot of Drain Pipe Drainage Fill 1" Minus Crushed Rock 6" Diameter Rigid PVC Perforated Pipe r 9