DESCRIPTION OF WORK:
DEMOLISHING EXISTING OFFICE AREA (APPROX 1300 SF). INSTALLING NEW OFFICE TO WAREHOUSE SEPARATION
WALL; REMOVING EXTERIOR STOREFRONT. INSTALLING OVERHEAD DOOR.
Value of Construction: $ $14,000.00
Type of Fire Protection: SPRINKLERS
Type of Construction: VN
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
doc: Devperm
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
SPECULATIVE SPACE
10838 EAST MARGINAL WY S, TUKWILA WA
E MARGINAL WAY PROPS LLC
3006 NORTHUP WAY STE 101, BELLEVUE WA
DAVE KEHLE
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
N
N
N
N
N
N
N
N
N
N
N
N
DEVELOPMENT PERMIT
Private: N
Profit: N
Private: N
D03 -353
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 206 433 -8997
Phone: 425 369 -8655
Expiration Date:03 /04/2004
Fees Collected: $395.96
Uniform Building Code Edition: 1997
Occupancy per UBC: 0016
Number: 0
Start Time: End Time:
Volumes: Cut 0 c.y. Fill 0 c.y.
Start Time: End Time:
Size (Inches): 0
Public: N
Non - Profit: N
Public: N
D03 -353
12/10/2003
06/07/2004
Printed: 12 -10 -2003
doc: Devperm
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Permit Center Authorized Signature:
D03 -353
Date: 1-2 "∎°
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating cons ction or the " performanc of work. I am authorized to sign and obtain this development permit.
Signature: ��- /1 /�_ �.I.0 Oh ��"1 Date: h2 — JO -
Print Name: /)t12i'd)L 77d 1I-2x'D
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
Printed: 12 -10 -2003
City of Tukwila
PERMIT CONDITIONS
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 0323049164 Permit Number: D03 -353
Address: 10838 EAST MARGINAL WY S TUKW Status: ISSUED
Suite No: Applied Date: 11/12/2003
Tenant: SPECULATIVE SPACE Issue Date: 12/10/2003
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division.
3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical
work will be inspected by that agency (206- 835 - 1111).
4: All mechanical work shall be under separate permit issued by the City of Tukwila.
5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any
construction. These documents are to be maintained and available until final inspection approval is granted.
6: Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3.
7: Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length.
8: Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear
identification showing the fire performance rating thereof.
9: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997
Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition).
10: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be
construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any
other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this
code shall be valid.
11: There shall be no occupancy of the building(s) until the final inspection has been completed by the Tukwila Building
Inspector.
12: ** *FIRE DEPARTMENT CONDITIONS * **
13: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following
concerns:
14: Maintain fire extinguisher coverage throughout.
15: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5)
16: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors
shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of
an approved type. (UFC 1207.3)
doc: Conditions
D03 -353
Printed: 12 -10 -2003
«". S: v.. I+ YR: c.' h1l ?.974Y6�•in�uk+W:l�SttiLti0.N�tid
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
17: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (UFC 1207.3)
18: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212)
19: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating
and /or adding sprinkler heads.
20: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions
and under overhangs greater than four feet wide. (NFPA 13- 4- 5.5.3.1)
21: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal
to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance
#1901)
22: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance
#1900 and #1901)
23: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70)
24: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to
location on property, fire resistive requirements based on type of construction, draft stop partitions and roof
coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored
or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1)
25: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and
properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed.
26: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed
description of intended use.
27: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
28: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work.
Signature ta ) a-tuLdeD
doc: Conditions
D03 -353
Date: /�
Printed: 12 -10 -2003
0838 Ea6f m
Tenant Name: 5 C . ate
Property Owners Name: L GD
Mailing Address: 30069
Site Address:
Name:
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
\applications \pcnnit application (3-2003)
3/2003
CITY OF TUKWIL4
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
uLe. .h(.e�
Mailing Address: I ,A/AD Giatettiaj bV i V-e l
E -Mail Address: CI k zh( 6.e.toye.4. Ca,yj
Page 1
Building Permit No
M echanical Permit No.
Public Works ?ermi '
! roject No
City
or office :se,o »1y;
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
King Co Assessor's Tax No.: 0 3CJ`-1 -- " 4 J(4 - 09
WaJ 6o . Suite Number: Floor:
eVeLna/ `6,11! J
New Tenant: .... Yes
W4 . g�OO
State Zip
Day Telephone: ‘.2 O co •4' 3 -p qq
rfattt e_ WA. r6,8,
City hh State Zip
Fax Number: oA(:)(P - -
State
Zip
City
Day Telephone:
Fax Number:
Contractor Registration Number: Expiration Date:
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
ARCHITECT OF RE CORD All plans must be wet stamped by Architect of Record
Company Name: Da U CL Q ivy / d1 ( K /{,`
Mailing Address: !,P � Q,,�ez<i Lj b✓(✓e, #1IC, a.jtx td A 9hIe,,8
, City Slat Zip
Contact Person: .1...X11 Day Telephone: O1P - /' 5 - q' 7
E -Mail Address: d h e,h (e 06ecu)6t, (:D/)1 Fax Number: 0 4,0 ' - &3(11
: ENGINEER OF RECORD — All plans, must be wet stamped by Engineer o f Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
..u, �.r. ntG[wku ail
UILDINGPEIIMITINFO
Valuation of Project (contractor's bid price): $ I 000 11 Existing Building Valuation: $
Scope of Work (please provide detailed information): J)erY1i) /15 h - i. held ( - ('6�CP '{ t' - Iift.S+ILL /
6
l� QrPox. 130 SF.
Will there be new rack storage? [] ..Yes
\applications \permit application (3.2003)
3/2003
6=431 = 3670
to)
o If "yes ", see Handout No.
Page 2
y
for requirements.
Provide All Building Areas in Square Footage Below
Pt Floor .. .
Z"a Floor
3r" Floor
Floors .thru
Basement-";
Accessory. Structure*
Attached Garage
Detached Garage
Attached: Carport
Detached Carport
Covered Deck
Uncovered Deck
Interior
Remodel
Addition to
Existing
Structure
New
Type. of
Construction
per UBC
N s P.
Type of
Occupancy per
UBC
PLANNING DIVISION:
Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: (+ �1 H r andicap::
Will there be a change in use? ..Yes ❑ ..No If "yes ", explain: / SF Ot offta. `N ogreAva i-}
FIRE PROTECTION/HAZARDOUS MATERIALS:
X r . Sprinklers ❑-Automatic Fire Alarm E]..None . Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ ..No
If "yes", attach list of materials and storage locations on a separate 8-1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
Scope of Work (please provide detailed information):
Water District
❑...Tukwila 0... Water District #125
❑ ...Water Availability Provided
Sewer District
❑ ...Tukwila ❑... ValVue ❑ .. Renton ❑ ...Seattle
❑ ...Sewer Use Certificate ❑... Sewer Availability Provided ❑ .. Approved Septic Plans Provided
❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department.
Submitted with Application (mark boxes which apply):
❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ")
❑...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑...Traffic Impact Analysis
❑...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑...Hold Harmless
Proposed Activities (mark boxes that apply):
❑ ...Right -of -way Use - Nonprofit for less than 72 hours
0 ...Right -of -way Use - No Disturbance
❑ ...Construction/Excavation/Fill - Right -of -way
Non Right -of -way
❑ ...Total Cut
❑ ...Total Fill
❑...Sanitary Side Sewer
❑ ...Cap or Remove Utilities
❑ ...Frontage Improvements
❑ ...Traffic Control
❑ ...Backflow Prevention - Fire Protection
Irrigation
Domestic Water
❑ ...Permanent Water Meter Size... WO#
❑ ...Temporary Water Meter Size.. S S WO#
❑ ...Water Only Meter Size WO#
❑ ...Sewer Main Extension Public Private
❑ ...Water Main Extension Public Private
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
❑ ...Water ❑ ...Sewer
Monthly Service Billing to:
Name:
Mailing Address:
Water Meter Refund/Billing:
Name:
Mailing Address:
\applications \permit application (3.2003)
3/2003
Please refer to Public Works Bulletin #1 fees and estimate sheet.
cubic yards
cubic yards
Call before you Dig: 1- 800 -424 -5555
❑ .. Abandon Septic Tank
❑ .. Curb Cut
❑ .. Pavement Cut
❑ .. Looped Fire Line
)t
I
❑ ...Sewage Treatment
❑ .. Right -of -way Use - Profit for less than 72 hours
❑ .. Right -of -way Use — Potential Disturbance
❑ .. Work in Flood Zone
❑ .. Storm Drainage
Page 3
❑ .. Highline
City
City
❑ ...Renton
❑ .. Grease Interceptor
❑ .. Channelization
❑ .. Trench Excavation
❑ .. Utility Undergrounding
❑ .. .Deduct Water Meter Size
Day Telephone:
State Zip
Day Telephone:
State Zip
Unit Type:
. Qty ::
Unit Type:
Qty
Unit Type ::
Qty .
` Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit
>= 10,000 CFM
Other Mechanical
Equipment
0 -3 HP /100,000 BTU
Furnace>100K BTU
Evaporator Cooler
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan
15 -30 HP /1,000,000 BTU
Suspended/Wall /Floor
Mounted Heater
Ventilation System
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood
50+ HP /1,750,000 BTU
Heat/Refrig/Cooling
System
Incinerator - Domestic
Air Handling Unit
<= 10,000 CFM
Incinerator — Comm /Ind
MECHANICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address:
State Zip
Contact Person:
E -Mail Address:
Contractor Registration Number: Expiration Date:
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Use: Residential: New ....
Commercial: New ....
Fuel Type: Electric Gas ....❑ Other:
Indicate type of mechanical work being installed and the quantity below:
RMIT'APPLICATIUN NOTE = Ap plicable to all peirmits >Iil
4
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as
defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
I HEREBY CERTI AVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PE URY e� ii LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING 0
Signature:
Print Name:
Mailing Address: 1,% . *Jt ay
Date Application Accepted:
Date Application Expires:
Staff Initials:
i
tapplications\permit application (3.2003)
3/2003
�il U-r oc_ h),L„
D AGENT:
7
Replacement ....
Replacement ....
Page 4
.5e
City
City
Day Telephone:
Fax Number:
Date: — /a' - OJ
Day Telephone: ? O (O - `1'JS " 8 7
` QQ
qb/ i∎Ov
State Zip
z
1 z
,1-- w
re 2
Parcel No.: 0323049164 Permit Number: D03 -353 _I 0
Address: 10838 EAST MARGINAL WY S TUKW Status: PENDING N o
Suite No: Applied Date: 11/12/2003
Applicant: SPECULATIVE SPACE Issue Date: _ H
w
2
Receipt No.: R03 -01364 Payment Amount: 154.21
co
Initials: SKS Payment Date: 11/12/2003 01:25 PM H w
User ID: 1165 Balance: $241.75 z F
ZO
U • 0
O -
O l--
w w
• U
Type Method Description Amount O
Payment Check 15809 154.21 ai
U =
0 ~
z
Payee:
TRANSACTION LIST:
ACCOUNT ITEM LIST:
Description
doc: Receipt
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
DAVID KEHLE ARCHITECT
PLAN CHECK - NONRES
RECEIPT
Account Code Current Pmts
000/345.830 154.21
Total: 154.21
46:1'; 11.i•..L 2 97.1.6 TOTAL j `4.21
Printed: 11 -12 -2003
RECEIPT ` 1 Z
re 2
Parcel No.: 0323049164 Permit Number: D03 -353 6 v
Address: 10838 EAST MARGINAL WY S TUKW Status: APPROVED U 0
Suite No: Applied Date: 11/12/2003 co W
Applicant: SPECULATIVE SPACE Issue Date: w tz-
W O
2
Receipt No.: R03 -01469 Payment Amount: 241.75 g 5
co
Initials: SKS Payment Date: 12/10/2003 04:18 PM z w
User ID: 1165 Balance: $0.00 Z i
iI— O
Z IH
W
• W
Payee: DAVID E. KEHLE ARCHITECT ' v o
O S,
O I—
W W
Type Method Description Amount I
U. O
Payment Check 15850 241.75 lllZ
U =
O ff'
TRANSACTION LIST:
ACCOUNT ITEM LIST:
Description
doc: Receipt
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
BUILDING - NONRES 000/322.100
STATE BUILDING SURCHARGE 000/386.904
Account Code Current Pmts
237.25
4.50
Total: 241.75
ITO 12/15 9716 TOTAL 1100.00
\A
Printed: 12 -10 -2003
�+....n;..isua[,iv. Diu .,:.r.�i.:"va:,:.......riu:.::.: , +; •n:,; i7:s „r.,n 45:i<'i:uWawS:A,' •iu:..:,t�.:,s,:C:a::
Z
Pr9ject:
Type of
)OJ'/ E. / Z-7�I
Date Call
%- .3 —G q
Special Instructions: t _,7 .
Date Wanted: �'
a.
Requester:
Ph /
7 S 7(5
94
✓:Wa!»uM464.4,41, ..Onith#41 .WiE'Y9tl1.7f,
: g�J, iisaahkt;..„ ,..z:C.M, _.:, >��
INSPECTION RECORD
Retain a copy with permit
INSPECT NO. PERMIT O.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2'6)4 1 -3670
Approved per applicable codes. Corrections required prior to approval.
$47.00 REINSPECTIONfEE REQGIRED. Prior to inspection, fee must be
paid at 6300 Southcen er Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
COMMENTS:
COMMENTS:
2/441. _ a yrA -(I .5 — dr.),./fr —c
0 ( /Pi/Jr /'_. ✓t,IA 1/9n. --, •�-
/ 0, e
kl
oC) Z/5
/ , NI { 77∎1 Y'4 / C. — Ale<Ae
V /
Date Called:
/' D#
/+CG�i / J IA/�1 / / v 6 . # 67''
,,_3)
A/e97 : glecl-7 i ;,9 / �7V5peod7 -/u>) &AsiCl
ca , �:5 . " (.fj/j )1 4 ' 4 /'its 5
, YtIY,
/h-Ad coops /v in/c0, ,t l erewee
`
Requester:
/ 075 7.-S
yro d t:
2 Ecu,4 r
t'e- ,_5;94(e
Type of Inspection:
• f
Address*
i
A i ,.
Date Called:
/' D#
Special Instructions:
!'�.. _)
_
V 5 ,
r,Ph
Wanted: •.,.
1 -mod ^off
`
Requester:
/ 075 7.-S
''' 4P(
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
pproved per applicable codes.
Corrections required prior to approval.
.00 REINSPECTION NEE REQUIR
paid at 6300 Southcenter Blvd., Suite 1
Receipt No.:
•
PERMIT
Date:
0
. Prior to inspection, fee must be
00. Call to schedule reinspection.
Date:
EN ct:
ittit
6v.--)
v.9 .y
Type of In pection
Ad boaA e ,
Ad r ess:
?lions:
..
/
Date called. }
. c. I j.2- bef
Spi c al
r
Date Wanted:
�/ ��
•
Requester:
Pho a No:
tvikiZ °i;:S'w(i.:;;uw,.S�1ta�.� V.;tk�ii,.li�+t:+:e -tic;:. .:iit:��. <.ii!!ir...a . ��.
INSPECTION RECORD
Retain a copy with permit
Do3-353d
INSPECTION NO. PERMIT/NO:
I -
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 3
-3.70
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
Ins ect r: N .4.__,
DatI: 3
4 .00 REINSPECTION FEE REQUIRED. Pr' r to inspection, fee my t be
p id at 6300'Southcenter Blvd., Suite 10 . Call to schedule reinspection.
Receipt No.:
Date:
COiDN4ENTS:
Type of ns�,. tion:
- . 4 ' ~ ' 1 -- 6 74//
C
Address:
3( 6 i /71/9#6,
Date C. • .
` — J 9
S ecial Instructions:
1
./,
----,
e
/ -5-7 r/li z 7 - 1.7
6
9
_'Ai , Li _ i
c t
- -, l i
r"
1
Projec •
? aL17 77/ 5*
Type of ns�,. tion:
- . 4 ' ~ ' 1 -- 6 74//
C
Address:
3( 6 i /71/9#6,
Date C. • .
` — J 9
S ecial Instructions:
Date Wanted: '
/ ~- f .- 4'3
a.m.
p.m•
Requester
PhoeN
I�� 7
6
INSPECTf ' NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TU!(.1tVILA BUILDING; DIV SION
6300 Southcen erj3 d., #100, Tukwila, WA 48'1'88 (206)431 -3670
Approved per applicable codes.
Corrections required prior to approval.
Date:
1'03
El $47.00 REINSPECTION F REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
7
COMMENTS:
''''") CUR i' i NS7f /4 / /;"711 — 49 Re%-g
Vv
a 0e,1 ,AA / / /Mir , :vs ; ' KV -
i ' /ee:5"s ° if .A67, 7‘i -2.,}veoiee o A e
ate Called:
7)-9,r/ , %&PA?, 443 /4/-,/// `�
`
.jar
0' (iTV - /id r ��i �r ��t/N P ,- 371
( " [/ e,/ i27 - C � (2 JZ Y / CA /Y-)-?7
n
( h
r
p.m.
Requester: ,s,
��'J
Projects P% °` 'v
,. ,, ...,,
•e of Inspect: . ./)ion . 1
Ty t /, �a ,T /T pl
A. r ress:
to
��� / �' j , S °
ate Called:
/1/ 3
Special Instructions:
i /o3
l J )
/
t ?1
Date Wanted:
14
r
p.m.
Requester: ,s,
��'J
Phone No:
/,..� / -/
� /tL✓'FO
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 South en ter 31 41 ila, 98188
Inspector'
p-
pproved per applicable codes. Corrections required prior to approval.
lF�t -..rte, )
47 s 0 REINSPECTION F
Receipt No.:
d at 6300 Southcenter
INSPECTION RECORD
Retain a copy with permit
Date:
(206)431 -3670
Date: l
9
i
REQUIRED. Prior to inspec ion, fee must be
Blvd., Suite 100. Call to schedule reinspection.
COMMENTS:
\ MW1 CA of 00 fOt)r
1 ( r
46,05 -- i0 -P1 !n
�r1( (t'
`votA 1 1A)d1k
Date Called.
. co. /cf n
N r4e • ` V n ✓\`-\• 0 -CS t,P re, I to!
j t(' `
.. 5 u)1 `\ Y\ e '
i
ff,.
` t `` 1 ( 4 it I l
('11 �� I��1 C le'rf r-..Dw\0 ISig
__.-
Pone No:
c -762,5 (PU (
T ect: c
(it javttssiottcx
Type of Insp tion: •
Add eP ss:
1c),3 E k
Date Called.
. co. /cf n
Special Instructions:
�/
ate Wanted: a.m:
1 / o10 3 (p.m.
Requester.
__.-
Pone No:
c -762,5 (PU (
�.ikt,st:az
INSPECTION NO.
Inspector: ,
• 1
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
00 3-353
Approved per applicable codes. El Corrections required prior to approval.
Date: /01_ () , z)
� w
El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
r. ,•; .;..y,:,.r7 "4�wL+'. rot •. , yy'/a iti_ ;Cbi4:'t' . nraS ,. ., �2�:a4tlf Ffy,1 NW; • '01 •- 0V1StKa
n
City of Tukwila
Fire Department
Project Name . , pl'c v cri; ✓e. S @ {,
l
Address 10.,E 3 �, /
✓ /
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
_ Re,tain .current. , inspection schedule :.
FINALAPP.FRM
Needs shift. inspection
s / Approved without correction notice
Approved with correction notice issued
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre -Fire:
Permits:
Authorized Signature
Rev. 2/19/98
Steven M. Mullet, Mayor
Thomas P? Keefe, Fire Chief
Permit No. 00 S - 3 - . 3
Date
Suite #
T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439
Opaque Concrete/Masonry Wall Requirements
Insulation on interior - maximum U- factor is 0.19
Insulation on exterior or integral - maximum U- factor is 0.25
If project qualifies for Concrete /Masonry Option, list walls
with HC 2 9.0 Btu/ft °F below (other walls must meet
Opaque Wall requirements). Use descriptions and values
from Table 20-5b in the Code.
Wall Description
(including insulation R -value & position)
U- factor
`� ° /p
Concrete/Masonry Concrete/Masonry Option tion
0 yes Check here if using this option and if project meets all requirements for the Concrete/Maso
Option. See Decision Flowchart (over) for g ualmT ="^ ^° °°'
or eac qualifying
......
jqj no assembly below. F f I F CO
Applicant Name:
-
Below Grade Walls
ray cw UkW LA
APPRO ►i ED
Ill IT
Floors Over Unconditioned Space
DEC —g 2t;d"f
Slabs -on -Grade
`(2
Radiant Floors
14 ) /S
Maximum U- factors
Opaque Doors
d '
Vertical Glazing
Space Heat Type
0 Electric resistance ,All other (see over for definitions)
Glazing Area Calculation
Note: Below grade walls may be included in the
Gross Exterior Wall Area if they are insulated to
the level required for opaque walls.
Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1.
(rough opening) Gross Exterior
(vertical & overhd) divided by . Wall Area times 100 equals % Glazing
/)�'1 • I� X 100 =
1
`� ° /p
Concrete/Masonry Concrete/Masonry Option tion
0 yes Check here if using this option and if project meets all requirements for the Concrete/Maso
Option. See Decision Flowchart (over) for g ualmT ="^ ^° °°'
or eac qualifying
......
jqj no assembly below. F f I F CO
Envelope Requirements (enter values as applicable)
Fully heated/cooled space
Minimum Insulation R- values
Roofs Over Attic
12 4.5
. 0 Ilt
All Other Roofs
For Building 1�4 D
t+
C T Y OF TUKWILA
NOV 1 2 2003
PERMIT CENTER
12 .'Z' tit
Opaque Walls
Applicant Name:
. 2'1 \
Below Grade Walls
12720 Gateway Drive au 116
Ill IT
Floors Over Unconditioned Space
Ii'a
Slabs -on -Grade
`(2
Radiant Floors
14 ) /S
Maximum U- factors
Opaque Doors
d '
Vertical Glazing
MP
Overhead Glazing
t4 14
Maximum SHGC (or SC)
VerticalOverhead Glazing
I I
Project Info
Project Address
Date II
12 4.5
I e v
5 ;W tlb�0��b�\
/•�•' I
For Building 1�4 D
t+
C T Y OF TUKWILA
NOV 1 2 2003
PERMIT CENTER
Applicant Name:
David 1 else Architect
Applicant Address:
12720 Gateway Drive au 116
Applicant Phone:
(206) 433 -8997
Envelope Summary
Climate Zone 1
ENV -SUM
2001 Washington State Nonresidential Energy Code Compliance Forms
Project Description
Semi- heated space 2
Minimum Insulation R- values
Roofs Over Semi- Heated Spaces
I \\
1. Assemblies with metal framing must comply with overall U- factors
2. Refer to Section 1310 for qualifications and requirements
Notes:
2001 V■ . .nington State Nonresidential Energy Code Cc' Form
❑ New Building ❑ Addition p Alteration ❑ Change of Use
First Edition, June 2001
Compliance Option
❑ Prescriptive *Component Performance ❑ ENVSTD 2.1 ❑ Systems
(4.0 not acceptable) Analysis
(See Decision Flowchart (over) for qualifications)
*e 353
AN Insulating Installed?
Opague Wall R -11
Masonry Wall (int) U -0.19
Masonry Wall(other) U -0.25
Below Grd Wall (ext) RIO
Below Grd Wall (obis) R -11
Roof Over Attic R-30
All Other Roof R -21
Raised Floor R -19
Slab-On -Grade R -10
Radiant Floor R -10
Opaque Door U -0.60
Glazing Criteria Met?
Glazing Vert OH
Area % UVal UVaI SHGC
0-10% 0.90 1.45 1.00
10-15% 0.75 1.40 1.00
15-20% 0.85 1.30 0.80
20-25% 0.60 1.30 0.65
AN Insulating Installed?
Opague Wall
R -11
Below Grd Wall (ext)
R -10
BelowGrd Wall (ath)
R -11
Roof Over Attic
R-30
All Other Roof
R -21
Raised Floor
R -19
Slab-On-Grade
R -10
Radiant Floor
R -10
Opaque Door
U 0.80
Glazing Criteria Met?
Glazing Vert OH
Radiant Floor
Area % UVaI UVaI
SHGC
0-15% 0.90 1.45
1.00
15-20% 0.75 1.40
1.00
20-30% 0.65 1.30
0.65
30-40% 0.80 1.30
0.45
All Insulating Installed?
Metal Framed Wall
11-0.062
Other Opaque Wall
R-19
Masonry Wall (int)
U -0.19
Masonry Wall(other)
U-0.25
Below Grd Wall (ext)
R -10
BelowGrd Wall (oth)
R -19
Rod Over Attic
R-38
All Other Rod
R-30
Raised Floor
R-30
Slab-On -Grade
R -10
Radiant Floor
R -10
Opaque Door
U-0.60
Glazing Criteria Met?
Glazing Vert OH
Area % UVa1 UVaI
SHGC
0-20% 0.40 0.80
1.00
All Insulating Installed?
Metal Framed Wall U-0.062
Other Opague Wall R -19
Below Grd Wall (ext) R -10
Below Grd Wall (oth) R -19
Rod Over Attic R-38
All Other Roof R-30
Raised Floor R-30
Slab- On-Grade R -10
Radiant Floor R -10
Opaque Door U 0.60
Glazing Criteria Met?
Glazing Vert OH
Area % UVaI UVaI SHGC
0-20% 0.40 0.60 1.00
2001 Washington State Nonresidential Energy Code Compliance Forms
2001 V% .nin ton State Nonresidential Ener. Code Cc 'lance Form
Envelope Summary (back)
Climate Zone 1
ENV -SUM
Decision Flowchart
for Prescriptive Option
Use this flowchart to determine if project qualifies for the optional Prescriptive Option.
If not, either the Component Performance or Systems Analysis Options must be used.
1302 Space Heat Type: For the purpose of determining building envelope
requirements, the following two categories comprise all space heating types:
Other: All other spew heating systems Including gas, solid fuel, oil, and
propane spew heating systems and those systems listed In the exception to
electric resistance. (continued at right)
Component Performance
or
Systems Analysis Required
Electric Resistance: Space heating systems which use electric resistance
elements as the primary heating system Including baseboard, radiant, and
forced air units where the total electric resistance heat capacity exceeds 1.0
Wfft of the gross conditioned floor area. Exception: Heat pumps and
terminal electric resistance heating in variable air volume distribution systems.
Totals
Area weighted HC: divide total of (HC x area) by Total Area
First Edition, June 2001
'If the area
weighted heat
capacity (HC) of
the total above
grade wall is a
minimum of 9.0,
the Concrete
Masonry Option
may be used.
"For framed
walls, assume
HC =1.0 unless
calculations are
provided; for all
other walls, use
Section 1009.
Pro}ect Address 10$ j KiXi Vii4 w�4‹
Date ``Iz. `b
Space Heat Type
0 E resistance 0 All other
For Building DepartmerittgemED
CITY OF TUKWILA
NOV 2 2003
Glazing Area as % gross exterior wall area
/'2 Prop.
I I' Max.Target
Concrete/Masonry Option
0 Yes ' No
Notes: If glazing area exceeds maximum allowed in Table, then calculate adjusted areas on back (over). If Concrete/Masortg, CENTER
used, Target U- factors, SHGC and Glazing % will be different than shown below. Refer to Table 13-1 for correct values.
Building Component
List components by assembly ID & page #
Proposed UA
U- factor x Area (A) = UA (U x A)
Target UA
U- factor x Area (A) = UA (U x A)
c
5
u 6,gZ Plan ID: ei, III Irlyvw
U= Plan ID:
U= Plan ID:
Ui = Plan ID: .
u= Plan ID:
U= Plan ID:
U= Plan ID:
0-62 '
140 G.
0' ID Ph; 2-I 1,
Glazing % Electric Resist. Other Heating
0-15% 0.40 0.90
>15 -20% 0.40 0.75
>20 -30% not allowed 0.60
>30-40% not allowed 0.50
(see Table 13-1 for Conc/Masonry values) -
uReIJ PeB v o I
g.
a
U= Plan ID:
U= Plan ID:
U= Plan ID:
U= Plan ID:
i 1 j
� P
Glazing % Electric Resist. Other Heating
0-15% 0.80 1.45
>15 -20% 0.80 1.40
>20.30% not allowed 1.30
>30 -40% not allowed 1.25
(see Table 13-1 for Cortc/Masonry'values)
a
i 0
f U=
U= Plan ID:
= Plan ID: I T�
Plan ID:
U= Plan ID:
a e
$ 8
0 c
U =0,3, Plan ID:`j., \Voo
U= Plan ID:
U= Plan ID:
O. grD X 42,
0,0o s1,- 41 ■ 4
Electric Resist. Other Heating
0.60 - 0.60
,, I
3 a
R= Plan ID:
1414,1k R= Plan ID: ,'
R= Plan ID:
Electric Resist. Other Heating
0.031 0.036 ..
S 8
cc
R= 11 Plan ID: Z' II ON 11'41..C4
R= Plan ID:
R= Plan ID:
b.0.1 'L 1 % {"f , 17). n
d ' b5 I I'O 10.5
Electric Resist. Other Heating
0.034 0.050
a
-
E.
R= II Plan ID: 17 VA .t.
R= Plan ID:
R= Plan ID:
R= Plan ID:
R= Plan ID:
R= Plan ID:
R= Plan ID:
* *Note: sum of Target Areas here should equal
041 > I 100 �
Target Opaque Wall Area (see back)
b- ** It) V O. d 2
**
**
Electric Resist. Other Heating
Ordinary 0.062 0.14
Conc(int) 0.19 0.19
Conc(oth) 0.25 0.25
. s
$ R=
0 s
R= Plan ID:
R= Plan ID: N k
Plan ID:
Note: if insulated to levels required for opaque walls, list above with opaque walls
Electric Resist. Other Heating
0.062 0.14
5 c ,1 r
R= Plan ID:
R= Plan ID: u i
R= Plan ID: I
R= Plan ID:
Electric Resist. Other Heating
0.029 0.056
5 ,a F,
d°_ 1
Q
R= d Plan ID: pt re�(1Y4Q
R= ID Plan ID: r U.1
R= Plan ID:
R= Plan ID:
b.13 r .ki ‘ \ b�j, 22A7
6' I I3 '
0 �� D el I P 6
Electric Resist. Other Heating
F=0.54 F =0.54
(see Table 13-1 for radiant floor values)
For CMU walls, indicate core insulation material. Totals
For compliance:
I
/ C>
�z ,
Totals
' f�(�
p9, i Z
chall not ,avr amp n a
11 Prnnnsnrl Tntal Arpa chat! pni dal Tarnat !Arai Area anri 71 Nrnnnsan i ntAl I I
2001 Washington State Nonresidential Energy Code Compliance Forms
2001 V. ,Alin ton State Nonresidential Ener Code Cc` 'lance Form
Envelope UA Calculations Climate Zone
ENV -UA
rv, ^ex�ro t+n•�'i�"r�%�b!»emr aeu;rgt wira e+w. rwsntrw.act ttrt£!,b?A
First Edition, June 2001
Glazing
List components by assembly ID & page #
Proposed SHGC
SHGC' x Area (A) = SHGC x A
Target SHGC
SHGC x Area (A) = SHGC x A
I Buzo
ID: 61, cliA510e1
ID:
ID:
ID:
ID:
ID:
Z t7 /-4'O
1 b
Glazing % Electric Resist. Other Heating
0-20% ' 1.00 1.00
>20-30% not allowed 0.65
>30 -40% not allowed 0.45
(see Table 13-1 for Conc/Masonry values)
'Note: Manufacturers SC may be used in lieu of SHGC.
Totals /
e
v40
Totals! d
Climate one 1 ENV -SHGC
2001 Washington State Nonresidential Energy Code Compliance Forms
For compliance: Proposed total SHGC x A shall not exceed Target total SHGC x A
NOTE: Since 1997 SHGC compliance for vertical and overhead glazing is allowed to be calculated together.
Target Area Adjustment Calculations
If the total amount of glazing area as a 1 of gross exterior wall area (calculated on ENV -SUM1) exceeds the maximum allowed in Table 13-1,
then this calculation must be submitted Use the resulting areas in the Target UA and SHGC calculations above.
Glazing Area
Opaque Area
Gross Exterior Wall
Area
I
X
Roofs over Attics
Other Roofs
Walls
Pro
2001'd..4hin ton State Nonresidential Ener. Code C` Thiance Form
Proposed Areas: Numbered values are used in calculations below.
Roofs over Attics Other Roofs
OG=
OG=
VG=
Max Glazing Area
(Table 13-1)
Target OG Area in Roofs over Attics
Max OG Remaining
0 lesser
ed O
Pos
paq
100
I
Walls
Maximum Target
Glazing Area
Target OG Area In Other Roofs
0 lesser
I
Target VG Area
I I
ue Area Pro used OG Area �J Ta et OG Areal Target O ue Area
+
Proposed Opaque Area Proposed VG Area Target VG Area Target Opaque Area
I I
I + I I
Note: If there is more then I type of wall, the Target VG Area may be distnbuted among them, and separate Target Opaque Areas found.
If the Target Areas for Opaque Walls listed on the front must equal the total calculated here.
Target values in shaded boxes are used In the applicable Target UA calculations on the front
Target VG Area and Total Target OG Area are also used in the applicable Target SHGC calculations above.
Fist Edition, June 2001
Note:
OG = overhead glazing
VG = vertical glazing
For Target OG's, the
lesser values are used
both here and below.
I Target Areas OK I
2001 V, .nin ton State Nonresidential Ener. Code Cr Fiance Form
Building Permit Plans Checklist
2001 Washington State Nonresidential Energy Code Compliance Fortes
ENV -CHK
First Edition, June 2001
Envelope - General Requirements
1311 Insulation
1311.1 Installation Requirements: Al insulation materials
shal be installed according to the manufacturer's instructions
to achieve proper densities, maintain clearances, and maintain
uniform R- values. To the maximum extent possible, insulation
shall extend over the full component area to the intended R-
value.
1311.2 Roof/Ceiling Insulation: Open -blown or poured loose -
fil insulation may be used in attic spaces where the slope of
the ceiling is not more than 3/12 and there is at least thirty
inches of clear distance from the top of the bottom chord of the
truss or ceiling joist to the underside of the sheathing at the
roof ridge. When eave vents are installed; baffling of the vent
openings shall be provided so as to deflect the incoming air
above the surface of the insulation.
Where lighting fixtures are recessed into a suspended or
exposed grid ceiling, the roof /ceiling assembly shal be
insulated in a location other than directly on the suspended
ceiing.
Exception: Type IC rated recessed lighting fixtures.
Where installed in wood framing, faced batt insulation
shall be face stapled.
1311.3 Wall Insulation: Exterior wall cavities isolated during
framing shall be fully insulated to the levels of the surrounding
walls. When installed in wood framing, faced batt insulation
shall be face stapled.
Above grade exterior insulation shall be protected.
1311.4 Floor Insulation: Floor insulation shal be installed in
a permanent manner in substantial contact with the surface
being insulated. Insulation supports shall be installed so
spacing is not more than twenty -four inches on center.
Installed insulation shall not block the airflowthrough
foundation vents.
1311.5 Slab- On-Grade Floor: Slab -on -grade insulation
installed inside the foundation wal shall extend downward from
the top of the slab a minimum distance of twenty-four inches or
to the top of the footing, whichever is less. Insulation installed
outside the foundation shall extend downward a minimum of
twenty -four inches orto the frostiine, whichever is greater.
Above grade insulation shall be protected.
Exception: For monolithic slabs, the insulation shall
extend downward from the top of the slab to the
bottom of the footing.
1311.6 Radiant Floors (on or below grade): Slab -on -grade
insulation shall extend downward from the top of the slab a
minimum distance of thirty -six inches or downward to the top of
the footing and horizontal for an aggregate of not less than
thirty-six inches.
If required by the building official where soil conditions
warrant such insulation, the entire area of a radiant floor shall
be thermaly isolated from the soil. Where a soil gas control
system is provided below the raciant floor, which results in
increased convective flow below the radiant floor, the radiant
floor shall be thermally isolated from the sub -floor gravel layer.
1312 Glazing and Doors
1312.1 Standard Procedure for Determination of Glazing
and Door U- Factors: U- factors for glazing and doors shall be
determined, certified and labeled in accordance with Standard
RS -31 by a certified independent agency licensed by the
National Fenestration Rating Council (NFRC). Compliance
shal be based on the Residential or the Nonresidential Model
Size.
Product samples used for U- factor determinations shall be
production ine units or representative cf units as purchased by
the consumer or contractor. Unlabeled glazing and doors shall
be assigned the default U -factor in Section 2006.
1312.2 Solar Heat Gain Coefficient and Shading
Coefficient: Solar Heat Gain Coefficient (SHGC), shall be
determined, certified and labeled in accordance with the
National Fenestration Rating Council (NFRC) Standard by a
certified, independent agency, licensed by the NFRC.
Exception: Sharing coefficients (SC) shall be an
acceptable alternate for compliance with solar heat
gain coefficient requirements. Sharing coefficients
for glazing shall be taken from Chapter 27 of
Standard RS-27 or from the manufacturer's test data.
1313 Moisture Control
1313.1 Vapor Retarders: Vapor retarders shall be installed on
the warm side (in winter) of insulation as required by this
section.
Exception: Vapor retarder installed with not more
than 1/3 of the nominal R -value between it and the
• conditioned space.
1313.2 Roof /Ceiling Assemblies: Roof /ceiling assemblies
where the ventilation space above the insulation is Tess than
an average of twelve inches shall be provided with a vapor
retarder. Roof /ceiing assemblies without a vented airspace,
where neither the roof deck nor the roof structure are made of
wood, shall provide a continuous vapor retarder with taped
seams.
Exception: Vapor retarders need not be provided
where all of the insulation is installed between the
roof membrane and the structural roof deck
1313.3 Walls: Walls separating conditioned space from
unconditioned space shall be provided with a vapor retarder.
1313.4 Floors: Floors separating conditioned space from
unconditioned space shall be provided with a vapor retarder.
1313.5 Crawl Spaces: A ground cover of six mi (0.006 inch
thick) black polyethylene or approved equal shall be laid over
the ground within crawl spaces. The ground cover shall be
overlapped twelve inches minimum at the joints and shall
extend to the foundation wall.
Exception: The ground cover may be omitted in
crawl spaces if the crawl space has a concrete slab
floor with a minimum thickness of three and one -half
inches.
1314 Air Leakage
1314.1 Building Envelope: The requirements of this section
shall apply to buildng elements separating conditioned from
unconditioned spaces. Exterior joints around windows and
door frames, openings between walls and foundation, between
walls and roof arxi wall panels; openings at penetrations of
utility services through walls, floors, and roofs; and all other
openings in the building envelope shall be sealed, caulked,
gasketed, or weatherstripped to limit air leakage.
1314.2 Glazing and Doors: Doors and operable glazing
separating concitioned from unconditioned space shall be
weatherstripped. Fixed windows shall be tight fitting with glass
retained by stops with sealant or caulking all around.
Exception: Openings that are required to be fire
resisia nt
1314.3 Building Assemblies Used as Ducts or Plenums:
Building assemblies used as duds or plenums shall be sealed,
caulked, and gasketed to limit air leakage.
4 dFsiw.a++:;,a:4),.%��.d+'a
Y lYe1Wo!MiM
Building Permit Plans Checklist ENV -CHK
2001 Washington State Nonresidential Energy Code Compliance Forms First Edition, June 2001
Project Address 101 �v .
4941 I r(,_ V /,,) , I
Date 1 1 1 1 ` U3
Yb in
The following information is necessary to check a builds permit a Natio for compliance with the building envelope requirements the
9 N n9 permit ppll P 9 Pe
Washington State Nonresidential Energy Code.
Applicability
(yes, no, n.a.)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
GENERAL REQUIREMENTS (Sections 1301 -1314)
1301
Scope
Unconditioned spaces identified on plans if allowed
1
1302
Space heat type:
l r "other, Ay
i ndicate on plans that electric resistance heat is not allowed
11
k
1310.2
Semi - heated spaces
Semi - heated spaces identified on plans if allowed
""t'—
1311
Insulation
(,t
_ 1
1311.1
Insul. installation
Indicate densities and clearances
—I. -1
1311.2
Roof /ceiling insul.
Indicate R -value on roof sections for attics and other roofs;
Indicate clearances for attic insulation;
Indicate baffles if eave vents installed;
Indicate face stapling of faced baits
��
.2
1311.3
Wall insulation
Indicate R -value on wall sections;
Indicate face stapling of faced baits;
Indicate above grade exterior insulation is protected;
Indicate loose -fill core insulation for masonry walls as necess;
Indicate heat capacity of masonry walls
if masonry option is used or if credit taken in ENVSTD;
1-2,
V\iP'
1311.4
Floor insulation
Indicate R -value on floor sections;
Indicate substantial contact with surface;
Indicate supports not more than 24" o.c.;
Indicate that insulation does not block
airflow through foundation vents
� I
1311.5
Slab -on -grade floor
Indicate R -value on wall section or foundation detail;
Indicate slab insulation extends down vertically 24" from top;
Indicate above grade exterior insulation is protected
li, Pc.
1311.6
Radiant floor
Indicate R -value on wall section or foundation detail;
Indicate slab insulation extends down vertically 36" from the top;
Indicate above grade exterior insulation is protected;
Indicate insulation also under entire slab where req'd. by Official
11
1312
Glazing and doors
Provide calculation of glazing area (including both vertical
vertical and overhead) as percent of gross wall area
- t ". 1
)Pc
1312.1
U- factors
Indicate glazing and door U- factors on glazing and door
schedule (provide area - weighted calculations as necessary);
Indicate if values are NFRC or default, if values are default
then specify frame type, glazing layers, gapwidth, low-e
coatings, gas fillings
11 r
1312.2
SHGC & SC
Indicate glazing solar heat gain coefficient or shading
coefficient on glazing schedule (provide area - weighted
calculations as necessary)
1313
Moisture control
9
1313.1
Vapor retarders
Indicate vapor retarders on warm side
x .'
IA 1313.2
I �
Roof /ceiling vap.ret.
Indicate vapor retarder on roof section;
Indicate vap. retard. with sealed seams for non -wood struc.
'--•--
tdl
1313.3
Wall vapor retarder
Indicate vapor retarder on wall section
�
•\1#r
1313.4
Floor vapor retarder
Indicate vapor retarder on floor section
N I
1313.5
Crawl space vap. ret.
Indicate six mil black polyethylene overlapped 12" on ground
1314
Air leakage
1314.1
Bldg. envel. sealing
Indicate sealing, caulking, gasketing, and weatherstripping
�t',,1
V
1314.2
Glazing/door sealing
Indicate weatherstripping
1314.3
Assemb. as ducts
Indicate sealing, caulking and gasketing
PRESCRIPTIVE/COMPONENT PERFORMANCE (Sections 1320 -23 or 1330 -34)
‘')\, Provide
Envelope Sum. Form
Completed and attached.
component performance worksheet if necessary
Provide ENVSTD 2.1 screen 1 output if necessary
PnC.p
2001 b. ,hington State Nonresidential Energy Code C f ,,.. -, liance Form
If "no" is shown for any question, provide explanation:
CITY OF TUKyyILA
N V 1 2 2003
PERMIT CENTER
7'c +Y�m}n14PgvMAt�
a
v:1 kr.,[1... • V A
•
vn ..,saa•
\VI)i)'! Z VIO V
rizve47\yut.
oi4vi-v pJrL x
i- ••7•,..-- • i i
ii
10 -1
p,a2- evto
Niqud „ 1 41
0 X 10 5 I CaA
six1'
:.„
detz a2
t, •
Icell,11.i 4io
II I 2403
c4 •
Noy - 2 2 17 :
PFIttfirozvrei4
Material
Thickness
Inches
R /In
Thickness
R Value
Solid
R value
Cavity
It'ipt eta k
• COI
3Y2" 9 tt.. 9ru17
v'(2.
-- _
.
I2 -I1
,'li
(0 , Ilo
11
l Orbit
•(01
•
-
. Summation R Values
. 8.61„
.
U = 1 /R
0.11
4
U Value for Element (Avg.) =
Area of Element* =
Element•. T
SKETCH OF ELEMENT
Note: Make copies of this form for every building element
Framing Ratio (if applicable) _ .
1 17, !�:tilic7 v"
iZ •II upirc4
*le air. en.
C4OR rV k1Nl
NOV 1 2 20 03
' Area of Element is net area after openings such as doors, window's and skytiet. have
been subtracted. MATT ��NrE
Material
Thickness
Inches
R /in
Thickness
R Value
Solid
R value
Cavity
1w5Acska 1414
0 4 ,0
IN:)utzetinti
312
t
61LI144 'tILt
1/4
Z •
1 • h i
1
Element: C'(.M'..ki
Framing Ratio (if applicable) se
U Va!ue for Element (Avg.)
Area of Element' =
* Area of Element is net
been subtracted.
SKETCH OF ELEMENT
Note: Make copies of this form for every building element.
. Summation R Values
U = 1/R
•
14. o -� 7i
. 0 4 184 '4 1 Z
Op r uk e t,
it 7ov 200 ;4
R
a•ea after openings such as doors, windows and skylights ha a '-'vTp,
Project Info
Project Address %
Y
we ll Lz-1 o
( D
I �I41 p �, b �\` I
WN 1/
For Building ggoa�tDErat.{ to
CITY TVU�K LA
NOV 1 2 2003
PERMIT CENTER
Applicant Name:
David Kahle Architect
Applicant Address:
12720 Gateway Drive Su 3.2.6
Applicant Phone:
(206) 433 -8997
p g g
Number of Watts/ Watts
Location Fixture Description Fixtures Fixture Proposed
Alteration Exceptions • No changes are being made to the lighting
(check appropriate box) • Less than 60% of the fixtures are new, and installed lighting wattage is not being increased
Location . Allowed
(floor /room no.) Occupancy Description Watts per ft Area in ft Allowed x Area
, alga 1.2 • 14-to 1(012-
0 \4011,61 0. 5 - (Q Iv V 10
" From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 4 �(oz
Location Number of Watts/ Watts
(floor /room no.) Fixture Description Fixtures Fixture Proposed
112/1
/4X 3't" torte w,e\e' w I aa, I�L,1 ',-1b I(o. $ 8 144.--
V/ u� UiiNtI 2- 2— 17 v
1A 'tl H(D WO6 1C 21D /61ao
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts �
Allowed Watts Area in ft Allowed Watts
Location Description per ft or per if (or If for perimeter) x ft (or x If)
Covered Parking
(standard paint) 0.2 W /ft`
Covered Parking '
(reflective paint) 0.3 W /ft
Open Parking 0.2 we we Outdoor Areas 0.2 W /ft
Bldg. (by facade) 0.25 W /tt
Bldg. (by perim) 7.5 W/It
Note: for building exterior, choose.either the facade area or the perimeter method, but not both) Total Allowed Watts
•
2001 Washington State Nonrestdential Energy Code Compliance Forms
20 Vashington State Nonresidential Energy Code C 'oliance Form
Lighting Summary
LTG -SUM
June 2001 - KIM
Project Description
❑ New Building ❑ Addition El Alteration ❑ Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
Compliance Option
Q Prescriptive ® Lighting Power Allowance 0 Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive 8 LPA spaces clearly on plans.)
Maximum Allowed Lighting Wattage (Interior)
Notes:
1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the
default table in the NREC Technical Reference Manual may also be used
2. Include exit lights unless less than 5 watts per fixture.
Proposed Lighting Wattage (Int&ibt»t all fixtures. For exempt lighting, not exception and leave Watts/Fature blank.
Maximum Allowed Li tin Wattage (Exterior) t'
Total Proposed Watts may not exceed Total Allowed Watts for Exterior
Use mtgr listed maximum input wattage. For tortures with hard -wired imam imam only,
Pro osed LihtinWattage (Exterior) the default table in the NREC Technical Reference Manual may also be used.
Total Proposed Watts
rt
NI)); lc+
Alteration Exceptions • No changes are being made to the lighting
(check appropriate box) • Less than 60% of the fixtures are new, and installed lighting wattage is not being increased
Location . Allowed
(floor /room no.) Occupancy Description Watts per ft Area in ft Allowed x Area
, alga 1.2 • 14-to 1(012-
0 \4011,61 0. 5 - (Q Iv V 10
" From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 4 �(oz
Location Number of Watts/ Watts
(floor /room no.) Fixture Description Fixtures Fixture Proposed
112/1
/4X 3't" torte w,e\e' w I aa, I�L,1 ',-1b I(o. $ 8 144.--
V/ u� UiiNtI 2- 2— 17 v
1A 'tl H(D WO6 1C 21D /61ao
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts �
Allowed Watts Area in ft Allowed Watts
Location Description per ft or per if (or If for perimeter) x ft (or x If)
Covered Parking
(standard paint) 0.2 W /ft`
Covered Parking '
(reflective paint) 0.3 W /ft
Open Parking 0.2 we we Outdoor Areas 0.2 W /ft
Bldg. (by facade) 0.25 W /tt
Bldg. (by perim) 7.5 W/It
Note: for building exterior, choose.either the facade area or the perimeter method, but not both) Total Allowed Watts
•
2001 Washington State Nonrestdential Energy Code Compliance Forms
20 Vashington State Nonresidential Energy Code C 'oliance Form
Lighting Summary
LTG -SUM
June 2001 - KIM
Project Description
❑ New Building ❑ Addition El Alteration ❑ Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
Compliance Option
Q Prescriptive ® Lighting Power Allowance 0 Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive 8 LPA spaces clearly on plans.)
Maximum Allowed Lighting Wattage (Interior)
Notes:
1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the
default table in the NREC Technical Reference Manual may also be used
2. Include exit lights unless less than 5 watts per fixture.
Proposed Lighting Wattage (Int&ibt»t all fixtures. For exempt lighting, not exception and leave Watts/Fature blank.
Maximum Allowed Li tin Wattage (Exterior) t'
Total Proposed Watts may not exceed Total Allowed Watts for Exterior
Use mtgr listed maximum input wattage. For tortures with hard -wired imam imam only,
Pro osed LihtinWattage (Exterior) the default table in the NREC Technical Reference Manual may also be used.
Total Proposed Watts
rt
NI)); lc+
Location . Allowed
(floor /room no.) Occupancy Description Watts per ft Area in ft Allowed x Area
, alga 1.2 • 14-to 1(012-
0 \4011,61 0. 5 - (Q Iv V 10
" From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 4 �(oz
Location Number of Watts/ Watts
(floor /room no.) Fixture Description Fixtures Fixture Proposed
112/1
/4X 3't" torte w,e\e' w I aa, I�L,1 ',-1b I(o. $ 8 144.--
V/ u� UiiNtI 2- 2— 17 v
1A 'tl H(D WO6 1C 21D /61ao
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts �
Allowed Watts Area in ft Allowed Watts
Location Description per ft or per if (or If for perimeter) x ft (or x If)
Covered Parking
(standard paint) 0.2 W /ft`
Covered Parking '
(reflective paint) 0.3 W /ft
Open Parking 0.2 we we Outdoor Areas 0.2 W /ft
Bldg. (by facade) 0.25 W /tt
Bldg. (by perim) 7.5 W/It
Note: for building exterior, choose.either the facade area or the perimeter method, but not both) Total Allowed Watts
•
2001 Washington State Nonrestdential Energy Code Compliance Forms
20 Vashington State Nonresidential Energy Code C 'oliance Form
Lighting Summary
LTG -SUM
June 2001 - KIM
Project Description
❑ New Building ❑ Addition El Alteration ❑ Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
Compliance Option
Q Prescriptive ® Lighting Power Allowance 0 Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive 8 LPA spaces clearly on plans.)
Maximum Allowed Lighting Wattage (Interior)
Notes:
1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the
default table in the NREC Technical Reference Manual may also be used
2. Include exit lights unless less than 5 watts per fixture.
Proposed Lighting Wattage (Int&ibt»t all fixtures. For exempt lighting, not exception and leave Watts/Fature blank.
Maximum Allowed Li tin Wattage (Exterior) t'
Total Proposed Watts may not exceed Total Allowed Watts for Exterior
Use mtgr listed maximum input wattage. For tortures with hard -wired imam imam only,
Pro osed LihtinWattage (Exterior) the default table in the NREC Technical Reference Manual may also be used.
Total Proposed Watts
rt
NI)); lc+
Location Number of Watts/ Watts
(floor /room no.) Fixture Description Fixtures Fixture Proposed
112/1
/4X 3't" torte w,e\e' w I aa, I�L,1 ',-1b I(o. $ 8 144.--
V/ u� UiiNtI 2- 2— 17 v
1A 'tl H(D WO6 1C 21D /61ao
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts �
Allowed Watts Area in ft Allowed Watts
Location Description per ft or per if (or If for perimeter) x ft (or x If)
Covered Parking
(standard paint) 0.2 W /ft`
Covered Parking '
(reflective paint) 0.3 W /ft
Open Parking 0.2 we we Outdoor Areas 0.2 W /ft
Bldg. (by facade) 0.25 W /tt
Bldg. (by perim) 7.5 W/It
Note: for building exterior, choose.either the facade area or the perimeter method, but not both) Total Allowed Watts
•
2001 Washington State Nonrestdential Energy Code Compliance Forms
20 Vashington State Nonresidential Energy Code C 'oliance Form
Lighting Summary
LTG -SUM
June 2001 - KIM
Project Description
❑ New Building ❑ Addition El Alteration ❑ Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
Compliance Option
Q Prescriptive ® Lighting Power Allowance 0 Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive 8 LPA spaces clearly on plans.)
Maximum Allowed Lighting Wattage (Interior)
Notes:
1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the
default table in the NREC Technical Reference Manual may also be used
2. Include exit lights unless less than 5 watts per fixture.
Proposed Lighting Wattage (Int&ibt»t all fixtures. For exempt lighting, not exception and leave Watts/Fature blank.
Maximum Allowed Li tin Wattage (Exterior) t'
Total Proposed Watts may not exceed Total Allowed Watts for Exterior
Use mtgr listed maximum input wattage. For tortures with hard -wired imam imam only,
Pro osed LihtinWattage (Exterior) the default table in the NREC Technical Reference Manual may also be used.
Total Proposed Watts
rt
NI)); lc+
Allowed Watts Area in ft Allowed Watts
Location Description per ft or per if (or If for perimeter) x ft (or x If)
Covered Parking
(standard paint) 0.2 W /ft`
Covered Parking '
(reflective paint) 0.3 W /ft
Open Parking 0.2 we we Outdoor Areas 0.2 W /ft
Bldg. (by facade) 0.25 W /tt
Bldg. (by perim) 7.5 W/It
Note: for building exterior, choose.either the facade area or the perimeter method, but not both) Total Allowed Watts
•
2001 Washington State Nonrestdential Energy Code Compliance Forms
20 Vashington State Nonresidential Energy Code C 'oliance Form
Lighting Summary
LTG -SUM
June 2001 - KIM
Project Description
❑ New Building ❑ Addition El Alteration ❑ Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
Compliance Option
Q Prescriptive ® Lighting Power Allowance 0 Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive 8 LPA spaces clearly on plans.)
Maximum Allowed Lighting Wattage (Interior)
Notes:
1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the
default table in the NREC Technical Reference Manual may also be used
2. Include exit lights unless less than 5 watts per fixture.
Proposed Lighting Wattage (Int&ibt»t all fixtures. For exempt lighting, not exception and leave Watts/Fature blank.
Maximum Allowed Li tin Wattage (Exterior) t'
Total Proposed Watts may not exceed Total Allowed Watts for Exterior
Use mtgr listed maximum input wattage. For tortures with hard -wired imam imam only,
Pro osed LihtinWattage (Exterior) the default table in the NREC Technical Reference Manual may also be used.
Total Proposed Watts
rt
NI)); lc+
•
2001 Washington State Nonrestdential Energy Code Compliance Forms
20 Vashington State Nonresidential Energy Code C 'oliance Form
Lighting Summary
LTG -SUM
June 2001 - KIM
Project Description
❑ New Building ❑ Addition El Alteration ❑ Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
Compliance Option
Q Prescriptive ® Lighting Power Allowance 0 Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive 8 LPA spaces clearly on plans.)
Maximum Allowed Lighting Wattage (Interior)
Notes:
1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the
default table in the NREC Technical Reference Manual may also be used
2. Include exit lights unless less than 5 watts per fixture.
Proposed Lighting Wattage (Int&ibt»t all fixtures. For exempt lighting, not exception and leave Watts/Fature blank.
Maximum Allowed Li tin Wattage (Exterior) t'
Total Proposed Watts may not exceed Total Allowed Watts for Exterior
Use mtgr listed maximum input wattage. For tortures with hard -wired imam imam only,
Pro osed LihtinWattage (Exterior) the default table in the NREC Technical Reference Manual may also be used.
Total Proposed Watts
rt
NI)); lc+
DEPARTMENTS:
Build ir `TYi 'is4
Public I s •` /c. //r oc l O �
(� /Qj
Documents /routing slip.doc
2 -28 -02
PLAN REVIEWIF�QtIT�YG SLIP
ACTIVITY NUMBER: D03 -353
PROJECT NAME: SPECULATIVE SPACE
SITE ADDRESS: 10838 EAST MARGINAL WY S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # /before permit is issued
572. /04, li J -o3 6/ n - 1 /-f8 --o3
Fire Prevention I� Planning Division
Structural ❑ Permit Coordinator X
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -18 -03
Complete d
Comments:
Incomplete
DATE: 11 -12 -03
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route gi Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 12 -16 -03
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
PERMIT COORD COPY
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
: .µ
WAY. r i w tifMsi' ".. ". , �4' iJ1F.aa' ^ SAd++. 1' :, 1iasaaL .(la4Y�ran'w'.1.1Y:eJ:ep:..i:Gi . .
Jul 10 03 07:57a
p.2
w•
F625.052.000 (8197)
DEPARTMENT OF LABOR AND INDUSTRIES
REGISTERED AS P,OVIDED BY LAW AS
CONST CONT GENERAL
REGIST. #. EXP. DATE
`•
CC01 "'MMTSEIt 94P5 03/04/2004
EPFECTYVE 'DA'E " '.. . 10/25/1991
M M I SERVICES INC
245'S 'SUNSET WAY
ISSAQUAH WA 98027
JUL 1 3 2003
•
•
J.O
N�
•
•
40 000 6.° 54; 0 11°.
it4
OJT I f .040
•
•
•
NORTH
•
•
•
•�
VICINITY MAP
Weir
• •
• •
•
N
ttl•
NOT TO SCALE .
S • •••‘•0; •
•
w
Co:
••
•
•
• •
!!
PROPERTY TAX ACCOUNT NUMBER
032304-9164-09
W
34 1 ..JELEIAL.
KJ NV
.�
••••
w•• .
S
0
0
0:0
ri sot
•• ,•
• • • •
_' • • •• • •
• ••
•
• �.
••
•
BUILDI 4 SITE STATISTICS
ON AMA
LOT FarnRcouwmr wr
IM MO APIA
1'OTAL INALDIMs.11,14111 e
pmci •DI *TALL
ANN& M' ICM
;240 .10 C01MILICTkp V.N
Qi1101 Or 4.1
RUINS CODIs Ill l MC
tEN�Nt .I�o�at�oN
aPICI•101 OF
= ;r'
3
S
• • •
•
I
•
••
r
•
•
•
•
e+
•
• A
LEGAL DESCRIPTIONS
• ►. i 00 .. -. • • .. •. M.•• 00. 00. • • -.... • •
83 MGM � � • r
811613172118 in 310MMIOrM 011 III8 UMW 111888811 SIP INV
Wet ISM MM SIM 1188111 I= MI aa 81188161 Ss
7MM &f/MA MM NUM MIS W47•$ 1881' 4441.611 Filia IS
IS IM MR OF 111181.8881
MMO SIO1181181111 AIM 81118 MI= Mr 3e•4 +•30 �!
NC OS Mil
111M38 1118.12 WIMP IS M . MUM UMW
ISOM 3818111111111M1 mum 124111MilleMil
3M'MM —== 111113 L LUIS Mil MM
IMAM 73'iO• �•1i•ir MI M' 111111 !M MRS/ •
- MM
•
III t Palegal Or TM SSIIRSOT pMMIM M MOC710M 4. 10 =s
33 MOMMA SOMS8 4 fMr IL.r. MP MS SOVIT+t• iu i.
MMtU Is Ni MMI
sosnomso 'M mrei minor or iiu ammo masa or as:
MAMMA& 1611. • WDS & Mid1 MOM KM Or is ssn. will
Ins GOYIM LIMs or SAID maw a. Rai0 Mahe inn iii.7t!
rust. MOMS SO u• sonsaga or !us sessuon COMM Or SAID .
socnool
eimes - 88•47.3S =M/'! AIMS Asa ieO'!' & M 324.70$
rim . Wig. MUM WS or nor
soon rows us uong Gowan 12411100FeekTo 7011111118
'MMrM FOUS ISS SAID MIMI SMOOT OP M Mt Or A
MVO TO 'M Sirt WINS A SAOMS Or 38i4.43 !.i v MO In
WMS AIM Or MA MU MOM 1s•1s•ss wiv. 3so.os11 :SM
TO PI MM or ISOIMOCTi
:mom OOMSzMozoo moo SAID 11001110111112 MOM 31•$3•$I UMW
133.:0 !SM 20 A IMF & AMM
IIMMIS Ate SUS /ART OM TM AOG OF A CMOMi TO TIM
RzOM WOWS A RAMS Or 11114.92 FM MO 'CIS 'M tO or
macs Naas MR 3.4•211•3$ 114/!. is M OI/3AMC! Or 000 •
flir JIM OR LM. TO Ills ROM Lin Or A TRACT
IM imam Sal or COMPIRACT is MID moos RSONSMIS MO.
10413.41 MID Mope AtaO UM 'M MOM LIM Or All 13112911310
PRIM! 1106011111I
110/311Cs emu 711I•13•3•• ism M PS SAID SMAIRIY tm 322
vamp MOM as lips 30 'elLit OMMIWIAMIU M1l Or & TOWS
33141 #OMO roe Salo VIM 'oars own auruaiR C MM's OMs
MO. 3130331 •
• TEM= Melt 00•37 MEW AWNS TM own MR Or MAID
TRAM 21.4 siM 'e0 a sOZM! as TER MUM WWI Or SAM!
Mi
IMP=S NMI 10.47.31 ip'!' 14310 ..LT MOBS OR too. AMMO
MID MUM 31111113111• 10 =It MCI Or OSIMINTINIi
WIRT TIM POWER OhM =M AO 101101114
C NNIIICiSO At A IOMM! OM 'eM sAMMM`a IMMM'rl UM Or sAMI.
MAY RAID PO!O! MIMI M!l 14•47•31 MIT 1307.23.5
MT M011 in lOiM! MOM 3'14 SAID RUT sow= LIMB
IIITERSOCTI TER SONE 1110LISIRT LIMM Or SAID acne* 31
MAIM w is SOOMI 10•47•30. OM! MOOS S Mi0 UST NMSIMAL
LiMS 1113.5211
s'aMCi Mrml 0$•37.314 UM! 333.103 tSM 30 & lOZII 70 fl
DI$TilMCS sear Slat Ci na Lis Or
RAZIMMs
TIMMCi CO INS AM amain CIMM MM'!MS A RADIOS OW 3934.93 PM
AM. Tin 141/'! IOIMRI WOO Or A CWMP SAM AND
TO MA331 tai um. 114 14MIS cam Or ARCM £0$ BABA MA
23•34•13" 1145! 141.403 MRS
TIM= MORlM 819•37•si Milt MIDI'S TER M IR BOOED= M'M! Or
A CM= ROAD 2433.019 FM TO '!s HMI Or
SOCZ'MIMS. .'
ALSO
U M" TIOOMON VOW r MO" ?MIDI LT Or TOE
gamma sum= LIMS; •
1sZIIM A!t 34S INTRIEO OF TER ROr '!M uaw a 'IOM Or MR
W. 01=1.1Mt SW= MM TSB SOOTS LAMS Or SAID SIMOM 33.
MIMI MOM WO NM= NOM w •47.314 1141!' 4441.110 rill 's
T1f1 TM Mar Or OWODMINO8
TIM= 11011111 73•13•30 MT TO TWI won= IOOl11MRY Oar '!M3.
!OBIT =ONO OOIMR Aas LZOil! . NINO=
TACOMA i'rwMMN;M ■• M M TIMM TIM OF
SAID LM.
FILE COPY -
I understand that the Plan Check approvals are
subject to errors and omissions and approval of
plans does not authorize the violation of any
adopted code or ordinance. Receipt of con -
tractors copy of approved plans acknowledged,
ay .1.. a
Date
Permit No.
%/MIX
SEPARATE PERMIT
REQUIRED FOR:
[11rI ECHANICAL
ELECTRICAL
LUMBING
GAS PIPING
CITY OF TUKWILA
BUILDING DIVISION
---
NO C1 E8 A i 1
" 1)63- -353
S.
ISCOVI
OplocasA
NOV 1 2 Se
vepw ce
S
4
a
0
C4
Set -0
/--ADD NEW
O�MIAT�CH
D(IQi11NS AND
MAXIMIZE
ear CODE
3110 WATTS
TOTAL
EX. GYP. BD
CEIL ING,
REPAINT
EX. CEILNG
TILES TO BE
REPLACED BY
DING
REMOVED TILES
PEW CEILING
GRID TO MATCH
EXISTING
r
63
i
0' I'
i
lin ON
(Ir.% REFLECTED CEIL L
SCALE: use • NY
• STANNIC 4 GRID MD TILE SCALE 1/1 • I - O'
• INSULATE ON TOP OF =LNG WR•NJ
• SWITCH !"OR 101lF101E LI6HRM6 t0 SE SEPARATE PROM ADJACENT TENANT
• REM O1Af1N2 TU. TO WA* DAMMED TIL[5
712,r
ros\
Ex. RAMP TO REMAIN
SEAL CONC. FLOOR
SEMI DATED TO MAX. 8 BTU.'
(PROVIDE UNIT NEATER AS REQUIRED)
.NEW STUD WALL TO
IC-6 AFF
PATCH AND RMP ASPHALT I
TO LEVEL VAN SLAP TO END
OF STALL /
0
OP flugaginmal -
, urv.i, ur • r.r
• ALL ORlN61QNO ,111E TO TF# fACS OP 811D8
•
•
:944- -
EXISTNG WALL
kW STEEL STUD wail
IOW STEEL STUD WALL, SCUC INSULATE
EXISTING WALL TO OE WOAD.
`MP MID Of/
.. MIN IIIIP
LEGEND
NMI
F7
EXIT
$3
NL
r 71
Lc'
0
f;11
is*
rcT
C
NEW DOOM
EXISTING DOOR
FOUR -FLEX OUTLET
DUPLEX OUTLET
WALL TELEPI.ICNE OUTLET, MIRING, CONDUIT AND PULL STRING.
WALL TELEPHONE/DATA OUTLET, MUDRINs, COPCUIT
SAND PULL STRING.
NEW OR RELOCATED 1' X 4' 3 -TIRE FLUORESCENT, MATT
EX 2' X 4' 3•TUOE FLUORESCENT, SS WATT TO REMAN
NEW CEILING GRID
ILLUMINATED EXIT SIGN
SWITCH
3 -WAY SWITCH
NIGHT LIGHT
EXISTING SKYLIGHT
INCANCESCENT LIGHT FIXTURE
NEW 3 BULB WALL MOUNTED INCANDESCENT LIGHT FIXTURE
EXHAUST FAN.
EXISTING PETAL HALIDE
r ;,;1
REMOVE EXISTING CEO Mao
— _AND RELOCATE LIGHT FIXTURES
PER NEW CEILING PLAN
•a
Le—
REMOVE EXISTING
HEADER SYSTEM AT -
CLG.
= I ====
WALLS TO BE
REMOVED OPEN
WAREHaUE
J
A
TILES Estues
-ant MIN Mai =Is Mr
mum. , wisi■ mama aims
Irm—*
REFk7VE EXISTING
STOREPROIT FOR NEW
DOOR
MINIM
RIB a
a2..'
A. OM. , MINED
- -
DEtIOPL,AN _
l'Z' ua. rr . r.e
• �c ac� REMOVED rius TO IREPAneMPLAa
MIN PI
ENERGY CODE NOTES
I) HEAT IS VIA GAS, NO ELECTRIC HEAT ALLOU.D
1) PROVIDE VAPOR ON ALL WALL TO TIE WARM SIDE
3) CAULK AND SEAL ALL OPEININGS TO OUTSIDE OR DATED SPACES
INCLUDING UMATHER4TRIPPING AT ALL EXTERIOR DOORS.
4) MAXIMUM ALLOWABLE LOAD FOR SWITCH IS SOS OF 20 AMP CIRCUIT.
5) PROVIDE DUAL LEVEL. SWITCHING IN ALL ROOMS ADJACENT TO
EXTERIOR WINDOWS
L IG34TING CALCULATION
,4LLOIL6&LE WATTAGE:
OFFICE 1,410 SF x 12 WATT/SF • 1,692 WATT
WAREHOUSE 6,340 SF x 03 UL4TT/SF • 3,110 WATT
TOTAL • 4 5 WATT
2'x4' FLUORESCENT FIXTURE (3TUBE) 86 WATT x 16 FIXTURES •
LIGHT BAR, 3 DECORATOR BALL 120 WATT x 1 FIXTURES •
METAL HAL IDE 250 WATT x 11 FIXTURES -
TOTAL
WALL TYPES
0
a
El
U
EXISTING EXPOSED TILT -UP CONCRETE PALL
EXISTING 6" STEEL STUD • 24" O.C, WITH 5/8" GYP. BD.
EACH SIDE TO STRUCTURE ABOVE
EXISTING 6" STEEL STUD • 24' O.C, WITH 5/8" GYP. BD. EACH
SIDE TO 10' -6" AFF, R -11 BATT INSULATION
EXISTING 3 If2" STEEL STUD (25 GA) • 24" 0rC., WITH R•11 BATT
INSULATION AND GYP. BD. EACH SIDE TO 10' - 6" AFF
NEW 3 V2' STEEL STUD (20 GA) • 24" O.C, WITH 5/S" GYP.
BD. EACH SIDE TO 10' -6" AFF, WIR -11 BATT INSULATION TO
1 AFF IIUVAPOR BARRIER ON tumm SIDE
ROOM SCHEDULE
12 FLOOR: CARPET NEW
BASE: 4" RUBBER PEW
WAILS: GYP. BD. PAINTED (EGGSHELL) NEW
CEILING: ACOUSTIC SUSPENDED CEILING •9'- 10"AFF EX AND NEW
5 FLOOR: VCT EX
BASE: 4" RUBBER BASE EX
WALLS: GYP. BD. PAINTED (EGGSHELL) NEW PAINT
CEILING: ACOUSTIC SUSPENDED CEILING •9' -10" AFF EX.
344 FLOOR: SHEET VINYL EX.
BASE: 6" COVED SHEET VINYL EX.
UL4LLS: GYP. BD. PAINTED (SEMI - GLOSS) PEW PAINT
CEILING: GYP. BD. PAINTED (SEMI - GLOSS) 08' ,GAFF NEW PAINT
U14NSCOT: 4' PLASTIC LAMINATE WAINSCOT EX
6 FLOOR: SEALED CONCRETE
BASE: NONE
WALLS: TILT UP CONC. I PAINTED GYP. BD. NEW PAINT
CEILING: EXPOSED CONSTRUCTION
DOOR SCHEDULE
El
E2
El
NEW 10' X 10' VERTICAL LIFT OI/ERNEAD DOOR W/
UEANER SEALS AND DOOR BOTTOM, SLIDE LATCH
EXISTING 3'x1' STOREFRONT DOOR
EXISTING 3'x1' WOOD DOOR ADD IEATI4ERSTRIP, SHEEP
AND LO KSET
EXISTING 3' X 1' WOOD DOOR
EXISTING PAIR 3'x1' WOOD DOOR
MEWED
CITY Of nIKWILA
Nov 1 2 2003
PERMIT CENTER
1) ••••353
1,42 WATT
240 UL4TT
3000 UL4TT
4,02 WATT
11/12/2003 1123 an WKST -4 /CAD /2002 /082281nv- Mckonkty /SPEC. SPACE /T1- T2.dwg
wow ...111..... OM
• •
a
z
0
H
z
riT3
a 0
�
rn >•
gi a
z
ca) a
u2
cr.)
z � �
2P-4
T -1
d 41
•
As ....amoomowsrasmaINI• • - r.a.. i -- t . •••••--
• •
BLACK TRACK
ALUM MAK
PlTAL CUT Ro7Tol
ONO- N AMNIA •
MIAMI TO ALLOW
GLASS CHANGING
GASKETS V4'
PALL WIN
W CD
WALL TO WJNDOU
ATTACH BOTTOM TRACK
TO C.ONC, FLOOR LW
POWDER DRIVEN
/*OCRS AT 24' oe
2 VZ" RUBBER
BASE • CARPET
wa.L $ECTION
SCALE: I -VZ' • rimy'
LIGHT FIXTU PROTECTION
SCALE: 1•IR" • r-r.
NOTE:
L USE N SEISMIC AREA
AS !WV BY CODE
2. S(PPOora PARES TO
BE 0 9 GA. • 4.4°
o/C CCNNECRED TO
BOTTOM CHORD OF
TRUSS IW 1 V4"
EYE SCREILS.
EMBED 1" MIK
CMOS AMR
MIN AMR
5EI5MIC 6RACNG
NOT TO SCALE
-I !if t !--
uluiIU■n•■....■..•r , ■uu1111MI■
PARABOLIC LENSED FLUORESCENT FIXTURE
FOR RECESSED LIGHTS 14 AN NSU.ATED
SUSPENDED CELNNGS
SILL BELOW
DEEP LIG TRACK ATTACH -
SILL AND CIO* GYP. OD. To
8TEiL TRACK lM9CmDE Ill' AIR
SPACE TO STEEL KID AND
ATTACW GYP. OD. TO STUD
TAPPG COMPOUND
OVER PAPER
COWER DEAD.
5/8' GYP. D.
ACOUSTICAL BLANKET
• SOwD WALL.
CAR.K GYP. BD. TO FLOOR
• ALL SaND AND INS L.
ILIALL5
talLATICN
I/1' GYP. eD. OR
CEILING TILES BIRACED OR
STRAPPED TOGETHER TO PROVIDE
AIR TIGHT ENCLOSURE III/INSULATION
ABOVE - STEEL SW FRAMING AS REaIIRED
TALL 1 12 GA.VERTIC:AL WIRE COMECTED TO
MAIN RUNNER s TO STIRJClU RE ABOVE. WALL A
SECTION OF (RIGID STEEL CONDUIT IWVERTICAL
WIRE RLIMING THRU CENTER OF PIPE. PIPE TO RIM
FROM TOP OF TEE TO BOTTOM OF STRUCTURE
ABOVE. WRAP MD OF VERTICAL WIRE AROUND
PIPE BOTTOMS. SEE ATTACHED TABLE FOR PPE
SIZE.
TALL 41 GA. WIRE CROSS BRACING N EA. PLANE
CF MAN RIPPER • 12'-0• 0/C • 4b ANGLE N BOTH
DIRECTIONS WINE FIRST PONT WITHIN *'.0" FROM
EA,. WALL
TABLE FOR PPE SIZING
Ii" • EMT COI IT•ACCEPTAINCE TO 4
RI' • EMT CONDUIT-ACCEPTANCE TO 9'4'
I' • Q'IT CONDUIT -ACCEPT AICE TO 6'4'
I14" • Ell CONDUIT-ACCEPTANCE TO 8'•2"
It1' • EMT CCNDUIT•AC.CEPTAINCE TO 8'•10"
AV- EMT CONDUIT-ACCEPT/CS TO *'4"
3' • EMT CONDUIT-ACCEPTANCE TO 2C'•1"
4" • EMT CONDUIT - ACCEPTANCE TO 26'4"
MOST OF THE ME E 18 TYPICALLY $TOOCED N 10'
LIM* COUPLNGS ARE AVAILABLE OM
NECIOANY. VALUES ARE BASED UPON
•TMD IND CALCULATION* IC CAN BE
OUNTANTIATED BY mo reiterech FIRM.
SECTION
FOR WALLS GREATER THAN 8'• 0' N
WIDTH WITHOUT AN INTERSECTNG
WALL, PROVIDE 12ga. WIRES SPLAYED
• ARV TO AN EYE • ROOF AND
TOP OF WALL
SECTION
SECTION
SOUND CA .K F' RIO R
TO ATTACNNG
GYP. BD.
WOOD FRAM DETAIL
SCALE: I -V2' • r-!r
-1 1) () "i•0435
TYPICAL STALL
FRAMING
ATTACH BOTTOM
TRAGIC TO CONC.
FLOOR IW POWER
DRIVEN /OM
AT 24' oz.
4' MEER
BASE • CARPET
UJALL to 5LAB
Oc4E: Mvr
CAIN WeRCP"
�pEC g 2003
,U)
•
S T E E L we) M . •'• V OC. TO
ROOF MIN M -
ATTACH TO TOP OF
WALL AND FUXN
WN.a 11°-
INSTALL vISauMe+ TO poor
DICK, nATaW WRING
BATT INSULATION
R•M • MATCH EXISTS
TY'P. MICE WALL
FRA I WISATT
WS LATION
3 IR' x 20 GA
STEEL STUDS •
24 O/C
3 I/?" MTL SW
2x WOOD BLOCKINS
2 VT" U OD CASN1G
1/2' x WOOD JAMB
x WOOD STOP
SOLID co IRE WOOD DOOR
S/8' GYP BD. EACH SIDE
SECTION
RECEIVED
CITY OF TUKWLA
MP GYP. BD. NOV 1 2 2003
CCNC. SLAB ON GRADE