Loading...
HomeMy WebLinkAboutPermit D03-379 - LUWA DISTRIBUTING - STORAGE RACKSLUWA DISTRIBUTING 1112 ANDOVER PK W D03 -379 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3523049053 Address: 1112 ANDOVER PK W TUKW Suite No: Tenant: Name: LUWA DISTRIBUTING Address: 1112 ANDOVER PK W, TUKWILA WA Owner: Name: LINCOLN CENTER HOLDINGS Address: C/O R 3 HALLISSEY CO INC, 12835 BEL -RED RD #140 Contact Person: Name: ROGER STUESSI Address: 18271 ANDOVER PK W, TUKWILA WA Contractor: Name: ENGINEERED PRODUCTS INC Address: 1033 6TH AVE S, SEATTLE WA Contractor License No: ENGINPI0133K DESCRIPTION OF WORK: INSTALLING NEW PALLET RACKING Value of Construction: $ $0.00 Fees Collected: $280.46 Type of Fire Protection: Uniform Building Code Edition: 1997 Type of Construction: VN Occupancy per UBC: 0025 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: N Storm Drainage: N Street Use: N Profit: N Water Main Extension: Water Meter: doc: Devperm DEVELOPMENT PERMIT N Private: N N D03 -379 Permit Number: D03 -379 Issue Date: 12/23/2003 Permit Expires On: 06/20/2004 Expiration Date:01 /01/2004 �..........— ...rw+w�X.'W M4 Li'.[, i..' ei. �Sr}' xll� :y?S.0.9Z1.i. +4.:i:i ✓ "..% Phone: Phone: 206 394 -3331 Phone: Public: N Non - Profit: N Public: N Printed: 12 -23 -2003 Signature: Print Name: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: // ?e mow` Date: /2 7B c)3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction . - performance of wor I a • authorized to sign and obtain this development permit. Date: //._ -3 0 3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D03 -379 Printed: 12 -23 -2003 z _1- w oC 00 • ILI J = H U) LL w cc< = • d 1_ z � I— 0 Z 1— w • w 0 O • N O H WW H ✓ - O .• z W — • 1 0 z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3523049053 Address: 1112 ANDOVER PK W TUKW Suite No: Tenant: LUWA DISTRIBUTING 6: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: DO3 -379 Status: ISSUED Applied Date: 12/10/2003 Issue Date: 12/23/2003 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 4: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 5: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 7: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 8: Maintain fire extinguisher coverage throughout. 9: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 10: No point in a sprinklered building may be more than 250 feet from an exit, measured along the path of travel. (UBC 1004.2.5.2.2) 11: Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) 12: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 5.5.3.1) 13: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 14: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) doc: Conditions D03 -379 Printed: 12 -23 -2003 15: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 16: In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 13) 17: Maintain minimum 6" longitudinal flue space between back to back racks. (NFPA 13) 18: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinklers at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 19: Depending on the classification of the commodity being stored and the size of the storage area, smoke vents, small hose stations and curtain boards may be required by Table 81 -A of the Uniform Fire Code. Contact the Tukwila Fire Prevention Bureau for further information. 20: Racks designed for high -piled storage must comply with section 2207 of the Uniform Building Code. Please contact the Tukwila Building Department for details pertaining to design and installation standards. 21: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 22: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Date: Print Name: doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 D03 -379 Printed: 12 -23 -2003 ak'iib.{r 71rA5:v44: 0:'.aiuz , , • - .. .... ' ✓.:r..i' 'x; �.!'.; King Co Assessor's Tax No.: Site Address: ///v? /1iv 4 U P2 ��n k 64JeS T• Suite Number: Floor: Tenant Name: u Gt1 O/• 7,Z /414- f`/ N f New Tenant: [] .... Yes ..No Property Owners Name: Z� Si y e--/./2p / � , -- /2 j I �' /l ' �- Ge Mailing Address:l )' P 3 el --/'c e-/( ✓�dQ G Q r� /Pic,.� 4114 • J Name: O, Mailing Address: /27.7 ( — A /—t p 6 E -Mail Address: /'Oy e.�+._ e l s y „L. L-c-,S 4. , G� s•, Company Name: 6 �✓ %/fr, e e u' C _237 Mailing Address: /e?.. 7 / - /.r,47 ) e .rr Contact Person: E -Mail Address: i"01 ept✓ CAS, c. 2 al ,4 . G a 347 Fax Number: 0 - 5 7 5 Contractor Registration Number: ./W G.2/) P D/ 3 Expiration Date: / //. 0 o * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** 1 plans must be wet stamped by Architect: of Record Company Name: Mailing Address: Contact Person: E -Mail Address: •'Ali; Plans; must ,be;wetstamPed.by.:Pigineer„of RCCOr Company Name: /ZS / L / A9 77. Mailing Address: l/ .2- Z — /�-� `` ��� .5� /r�� T" !. ✓� l 3 / Contact Person: , ?.'7S / C - i<" 7 r c G A E -Mail Address: bpplications\pennit application (3 -2003) 3/2003 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blv.,d., Suite 100 Tukwila, WA 98188 Page 1 City c: . Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** State Zip Day Telephone: .6- 3 r y - 333 / City State Zip Fax Number: c? e 75r —e t"J 4 Li/4 1. 7 City State Zip Day Telephone: o e - 3 y y' -33.3 / City Day Telephone: Fax Number: City State Zip Day Telephone: Z tS - 3F2-$:2- ?C Fax Number: 5 3 State Zip 4BPI DING?PE LT 431 = 3 ° r - ,x � �I ,INFURMATION -„20�= >� �� � „...,.,,.��.,:�; �. <;;; �fl,. ��..,�- ..�.w�4. � f ` +1 Y 7« :`� 7.'..z, .+ 3 • .• N "R . +,•..:1; N'.t .: `,l,ia.;t til. �F� �, .-' /.:: };i�K1�,y {. �y � .�.ri ^'' T.: �,MJ' ?.k';' 1� % �'{r7: �' " ��t�PZY, .�. � ` t ;�� � 4�, 1y t ri r t� c '�i � to P�y',' .4 `• :9i h: ^i�. �,4 .s �wu'ij Tr 4 J �'j� + . e :(pJi:ir'• .t + ;�v.i �i�.esf r � D,:. ��r , S;/:C \ 3:„i'�•..t�:'. #�'X, b�"`'� .r „�.r # •7 �i . t ;/ . ... l.y`, t .rt d'� y ” Valuat!lon ef- Project (contractor's'bid price,. ,t; c e.ro Scope of Work (please • provide detailed information): ,94 PQ /le r /44 c- i s, Will there be new rack storage? '] ..Yes O.. No If "yes ", see Handout No. for requirements. rovide. AII'BuildingAreas in Square :Footage Below 2 "° Floor: w Floor Floors :Basement Accessory.' Structure *. Attached Garage;:;.: Detached Garage Attached Carport Detached: Carport;: Covered .Deck ;: Uncovered Deck Addition: to Existing` Structure Typo of Construction !• per UBC .; Type of .Occupanc); per UBC PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? 0 ....Yes ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: [1. Sprinklers ❑_Automatic Fire Alarm ❑..None Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ..Yes ❑ ..No If "yes", attach list of materials and storage locations on a separate 8-1/2 x 11 paper indicating quantities and Material Safety Data Sheets. \applicationslpermit application (3.2003) 3/2003 Page 2 Existing Bu,... ng Valuation: $ 0 . Other (specify) Handicap: !ft+.W�+!ar•+,ns++. 4wk.6i,..ne�w......yF•,. wa:.r•w:..�... ., ..:• ... ... LIC,O 1ER[�' Scope of Work (please provide detailec .formation): Water District ❑ ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ... ValVue ❑ .. Renton ❑ ...Seattle ❑ ... Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size— 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ... Hold Harmless Proposed Activities (mark boxes that apply): 0 ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... 11 WO# ❑...Temporary Water Meter Size.. WO# ❑ ...Water Only Meter Size II WO# ❑ ...Sewer Main Extension Public Private ❑ ...Water Main Extension Public Private FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ... Sewage Treatment Monthly Service Billing to: Name: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: Day Telephone: City State Zip 4pplicationslpermit applic�fipp ( 3ot y' 3/2003 ease:refer Public Works Bulletin #E for fees and estimate sheet. cubic yards cubic yards tiAlVA ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line /1 Call before you Dig: 1- 800 - 424 -5555 ff ❑ .. Highline ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage :a y : Page 3 ❑ ...Renton ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size rgd � N Unit Type: • • . , Qty : : ;:Unit Type :: Qty:' .: Unit Type Qty '.:: Boiler /Compressor Qty . Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended /Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm/Ind J .ORMATI CHN�CAL E'ERtTINF, . �� ^�U•�S +'a:�... .. r „[.r. <s'u ?...t . :`t'� 2;:OT MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: State Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New ....0 Replacement .... D Commercial: New ....0 Replacement ....0 Fuel Type: Electric 0 Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE R AUTHORIZED ASiEN • Signature: /� — ■ Print Name: ? -ti \appliationslpermit application (3.2003) 3/2003 Mailing Address: . ).-7 / a sp tivP,�. w e ; z� Page 4 �rfy.Yy9ti :'- f�"Art�rrl��+�•fN'hit� IWYEj'F:. . �,�,>Rarei ta�;a;t�.Ja6ytiL`. Cep City 4 State Zip City Day Telephone: Fax Number: Date/ 3/63 Day Telephone: D -61 - - 3 3 3 / Zip z RECEIPT ,i_ z re 2 Parcel No.: 3523049053 Permit Number: D03 -379 Address: 1112 ANDOVER PK W TUKW Status: PENDING 0 0 Suite No: Applied Date: 12/10/2003 w Applicant: LUWA DISTRIBUTING Issue Date: N w00 Receipt No.: R03 -01470 Payment Amount: 280.46 J g � a Initials: SKS Payment Date: 12/10/2003 04:31 PM H w User ID: 1165 Balance: $0.00 z ii— 0 Z I-- U.1 U 0 - 01-- w ii i 1— Type Method Description Amount LL'O z U Payment Check 8629 280.46 l L i in = O~ Payee: TRANSACTION LIST: ACCOUNT ITEM LIST: Description doc: Receipt City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 ROGET H. SfUESSI BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/345.830 000/386.904 167.25 108.71 4.50 Total: 280.46 3568 12/15 9716 TOTAL 280.46 Printed: 12 -10 -2003 Z COMMENTS: n ario dei 5 A -- e H `Pi-� � S Q � A Y 'irk+ ' • . .. !� _ c !R . R.. �!...._.�.rl� C°:.r• i"Ili'�1ii� � � i�:eLir.r�. vF k P IL W Date Called: ^7 — / a `/ 6_ r 0 Af s fr f f t0 P i\ s-/-i) ( I l; + LA A A e b, \v- af\) f) (-jam i PI PA (;_i .01441-K‘ 01 ". > \( f) \-013 yvN i- A• 1r P t t 16 3 5 '.. e e Ci /1-0 I L' ( / Z 1 V' t° 1,--(YAM 1,I Ytn I`�' s1 c' N.1� V . lJ V Project: i ' 1tL J Type of Inspection: PA /'; / 1 /9 / Address: 1 1 2 vF k P IL W Date Called: ^7 — / a `/ Special Instructions: c "---- \ Date Wanted: 7- / a.m. 657 Requue -.0 7 71) Phone~fVo j:-.5---14-/ 3 IrI p INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 roved per applicable codes. INSPECTION RECORD Retain a copy with permit (//1 /v)_ _3' e (206)431 -3670 Corrections required prior to approval. Date (5 -(3'7 $4 .00 REINSPECTION I E REQUIRED. Pri r to inspection, fee must be pa at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. i No.: Date: i ry ..... ■r . �h Nt�....e�wa.L. t....y {R.Y�..i .r T.+Cl+f..w-. ^ t Project: % - ,P /S ?-T Type of Inspection: • 1 °—r3 -7 , s Ac(di,s l 4 • ul ' Date Called � Special Instructions: // - � - � f !C _ .. 7 -I ,Q /LG (s gE 5- 1/1/1)/ Date 7/ nted: a.m. �� — 2 P.m. Requester) �O fie Pho e No: ? c7V 0 b) 39 V 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. 1 ha t (206)431 -367 M Approved per applicable codes. COMMENTS: r r U) 1 /}Q 7 • 2 �t `t C kG vy -.{ m v+. erek\te( r `P IAC, I vl - y °'... ricts en w o Corrections required prior to approval. Inspector. e Q cpi a rtr. Date: _2L -. ❑ $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: COMMENTS: Ty pe of I , p pectin • • C evt4 - t - r rou) 11 ,( Date Called. Sp c C ') Rro \1 (' \ P In c, h 4 e r .S L or 01 a.m I fii- P.m. '`� Ctpfvbv c.. . 5 ((l� , 0* c kolinerch 1 e‘ P oomie:_ S 14 --D 1 T O , A op rovfet cwA 0 5 CCt1,t Toy - \V C. c ` _ . \'\•PC. 0 s 1`- hAI A \ i Li, f' Stet, i\ , 14 g r- Trie LI) I Pr 'ect: D. Ty pe of I , p pectin • • A dress: Date Called. Sp c C Ir ctio : Date Wanted: ri a.m I fii- P.m. '`� ;ter: P oomie:_ S 14 --D 1 T O tai YFvsi1«i! to tl } Frrw s`S?'i iti:a� . tai s '' . 1.. • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. 0 O. 'Corrections required prior to approval. Inspect Date: C` �- ( O i l $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor:. Pre -Fire: Permits: te vtievek FINALAPP.FRM City of Tukwila Fire Department 1 Project Name , 1 t,0c, i)1 54 IJL P Address • 11 / , ,,./rc>r' ✓' i2k. !� . . Retain current-inspection-schedule Needs shift inspection L. Approved without correction notice Approved with correction notice issued Authorized Signature TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM • •1 Rev. 2/19/98 Steven M. Mullet; Mayor r., Thomas 1? Keefe, Fire Chief Permit No. 003- 3 7 e Suite # Date ..: L��..., i...r.rnr...�t+.v4G l:w'.4. .'k•ti...��..ti,. .. . %, f:'� ;a4.`.. T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206 -575 -4439 January 19, 2005 Mr. Roger H. Stuessi Easy Up Storage Systems 18271 Andover Park West Tukwila, WA 98188 RE: Request for Extension — Permit No. D03 - 379 — LUWA Distributing Dear Mr. Stuessi: This letter is in response to your written request for an extension to Permit No. D03 -379. Based on the information received, the City of Tukwila Building Division will not be extending your permit. Your failure to respond to the City's last Correction Notice (dated July 19, 2004), and then complete and final this project was cited as justification for this denial. Please be advised that a new permit and associated fees will be required in order to complete the above noted project. A permit application and submittal checklist is enclosed for your convenience. If you should have any questions, please contact our office at (206) 431 -3670. Robert Benedicto Building Official /sks File: Permit No. D03 -379 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 FROM :EASY UP STORAGE SYSTEMS January 13, 2005 • :E'•M..S TO: Ms. Stephania Spencer CITY OF TUKWILA FAX: 206 -431 -3665 PHONE 206-431 -3670 FROM: Roger Stuess', • Storage Systems RE: Pe No D03 -379 PAGES: 1 (INCLUDI OVER SHEET) Stephania, For financial reasons, my customer, LTJWA, had to break the racking project up into 3 parts. We have finished the first two and plan to complete the Final phase within the next 90 days. Please keep this permit active for that period of time. Roger H. Stuessi, Sales Manager Easy Up Storage Systems 206-394-3331 (direct) 206 - 575 -6829 (fax) roger@easyupusa.com FAX NO. :206 -575 -6829 Fax . Cover Sheet ay PUtOtd Jan. 13 2005 05:56PM P1 4 • C L Cal . .04,ixartbIl Mat a • -ow) ezz,(4,cut ni1216 STORAG & MATERIAL HANDLING SPECIALISTS 18271 Andover Park West Seattle, WA 98188 Ph: (206) 394-3330 Fax: (206) 575 -8829 Toll Free: (800) 426 -9234 Mw,eng- prod- inc.com cam.- ��d. -�� G'-( i; r✓ .0.44/ aic 5aW4 $44 v' ii4 ii)41444K a,r:.tu June 17, 2004 Roger Stuessi 18271 Andover Park West Tukwila, WA 98188 RE: Permit Application No. D03 -379 1112 Andover Park West Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one - time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to July 24, 2004, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer Permit Technician Xc: Permit File No. D03 - 379 Bob Benedicto, Building Official City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director • Call the City Of Tukwila Permit Center at (206) 431 -3670 to arrange for the next or final inspection. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 12 -06 -2004 ROGER STUESSI 18271 ANDOVER PK W TUKWILA WA 98188 RE: Permit No. D03 -379 1112 ANDOVER PK W TUKW Dear Permit Holder: City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Permit Center at 206 - 431 -3670 to arrange for the next or final inspection: This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one - time extension up to 180 days. Extension requests must be in writirte and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 01/15/2005, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer, Permit Technician xc: Permit file No. D03 -379 Bob Benedicto, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 -431 -3665 f.¢ �titi��1����s' ��i Pi:�'�d�t /.k�'a ° � i::» '�Z.`, •.1,, triot A6 4 Jrue-rs .1" 6011 UP Cro/LA&c SilSreos 18271 #4 rAilk 5 iJ A 92/81 JA-AuMitej /6 ) 200 4 - isAcit -r 1Ckrrz4 A 2,1/22,- 12.47M "We k&4r WA t� 3/ 5 bracf STee:. Se LEc- lAM P-,4Cic5 R'Z. L01414 Di scittaWr LrJ 0.1 TOPA) I LA 143 . - DOM- 11.0 IT 1 c Mt.( u riel-spix) a 7114 fir "P We- a X " itk Pit 'nof .4 4ere7L67- "11-4.1ecr Of*.at 'Aril am Ve WY* fardrivi Letiet. I4o 1.4 Sie*D 01- 12-, Fir A'S 146: Pt/0 vriptt s436Aterreo 14-1-10 A P ItoV&P DerAtLs akaf-) "nl-ose 4c4 3 1,s L.t* Le. Le-jeu Jw1? 1 e c givao.o kW) rpogo • 1140 1144- 5.(11-61)E-s 143 Arm. N r Argt rt int-c$0 Ash . ?ickstS rtm- rite& To c.44A_ Air /ss 431 —10 Lrov- iftAroe Oakevrtags ,att- 'Jae° FIt.124s tAFO. ,u1 -- Lek,'ALivatiiiwo,c4kap:ktaAii ti3 Ult.& tail YE - 77 K4ffuLA AecervEo cm ThicwilA JAN 2 2 2004 PERMIT CENTER CM a 1 ,IEC 5 3 25/ AS violL ) LtSE wi14-6 LA c. GL4k -P 12. ttv. Vit r'a. l IQsM cf `a t S t i A ! C b t7 lut. E T 0 ('1.. i CA.1 A a. ✓) } 1.0 C = .36 SEISMIC ?o,.ae : (, 130) a= 4.4 - ntAlo S v. 1i 2 - I (LAt 6.0 FU Inca . R .2 G Lo►., Gig 44 .14 O.M44 A0 / (/.Et / p t.ft.. or fit ,ls»c $ l5 C) t(PE A (kcwcs ; !,ob L&. rot car I.F"s ;006 I g 4 roe- L) p(Ftt- t vt' IA) 1 '6" ;Apo Ito Jed!, l loo LA, s pelt- LtJez.. 13. gam& De71,0 !„ 4 ra BUIL 1 1VSON . 1.4,0 (.dG,?lob) 4- Z.b0.154 56t 56ts It o.set.. « Sec.. `L?.Z1.1,1 Sill M = 112.2,s 14- _ .._. ¶Es 2..41 It L.Alo k. \14 6 pit) (1- = L C 0 VII- z 0.380 € Is 7 T = 0.21 X 4 Y2" 641.1,T 14 PA)LTS C3 C-lit g l) pert -_ i3/1-1 p LATE' r z 2 o.i4S x 413 I.aa P -1.-.c.40 A 6(1.-4102.7 W 1T34ouT \ % )G /.34 k 413 = g Spec.!,-'_- t O s f c,riohi CT/TA-) C uiv'A) 5 h , w .9. 0 iflr.) k 1.0 Le,4 a� � Job IitleLl lJA .iA wk, B 15-rx Subject STEEL S eLEC'(►v gArGIt. /41.,1h'( Sl. S 1. if.�. ( iteo 64-04- `}7) tkkcx. , - 1A)t S` .3.0/2 4- .16 I. rook 1 L. /. l M � .012 + 41Z IT Lk le/1- 64,re fu Date Checked E)U'IRES ) t( 4/ -3 - - r o. d l� `l 49, 47 )4 / CAA 'efirl-,c. I~40 f r F v. 11,1147 /VV�. V to. 4'•1 it /124 L1M'M P'oflAC. £ C-2.7-1 z 1.24 14 FULA c.6;1 Ar12.6 1 1/2 g 1 14 OA A ,742. .4os Job No. 04-DO Sheet 1 of .• 4 l A 14 Artie) e,,, iE . °12.`t tc i .w ? : , i� ! "" °tea °F lvE° DEC 1 0 2 003 P E M,T CENTE, Job i ale By I' 7 it, Date 12 /03 Job No. 04002 Subject tvIlew (ICLIC), z I d ( 1D i : I.D I �, FG K 1Z3l tool ld;; A e. 4. 4- 13 1 ,2.10 1. PIC ?Ace LAe'rGs %L./14 Y V vi i [� Ei. yid �• ? Tt , � �•�., / t4 false puirfts.s x,.: ISA4E ptA7'f- wi P e zo ek . (2.5b)7 z = 0.43E k"/- • 0,75" 4-/3 36 gm() # 32fp " 6'•l;- ,4 C i L ' A (.. t 8 s4/ " 7WCik £' Ike Is)1rI1 { x, 5 . 0 p $1' 4'/fj N1 ,01 / f 0 , 48 'p 6 t1.r / to tru /YVLe LJ IF 7 1,0 ksF 4' v 5011 (ILaC. Aiso - (244at+ S.s4- s.o g 2,444- 5.5" ) .1 1 te 5 ,1. a. j : c' k ' "' , CITY TUKVVILA D , Gtr �2 APPROVED OF • . 9 € "A (Z ,rc.cs6 0,04.3r (2 L, art& -- 22'l `d , 5. = I, (,o k / Ieu . n I,)3 . 24 40 k I a1EC 1 8 2003 vL : • 110( • 6'1'(4c4• 2.,() s v . 333 k f G►L., A5 fYUIEU Z . �. 70tZ7k., . BUILDING DIVISION -heti& gothi41 M4 1 4 4 6446x. VI' O a P 144114' Stes M. 14- vo N S; D W Stt) MA 7 Ito" 14 Pt 1 4,0WS 2 ' c3) ,t AG- At � � , ry � 3 49 - - Pr; L k u) 54g 3/3" ,r 40 M k etc G fiatop -Fp = 0. 'Fe! i 4/3 /, ov '3 S 1,3 4 7 2 444 4- / h." Ma C- I N /11( ( o• " gQ4.0 4 SID La &LO 5 66"i k 9 2 ,423t S 1,024 �- $ro Lisew Seis ,I4 It, (ti Co Olt..e J 66A1U) Checked Sheet 2 of Ala o = .bv PsJ e ' a0.g4cf14 /, Job Title Subject BY 5K- 6 f1 c 9.,-/,90 to �, \.�S'titl4 i,) � L'i) 7►� a 7 (Solt, /2.) . 144/2, Ut Lr`% 6. A tS' /. C»0 Ln-( I_i-^k j tF.1.,J) M s W.00 4- .15• Ctim) lZ.�q. Imo' c )A, (3) AA 1144 h 4-5.90 ir epic) *4 2.7,11 4- ,1L&) -= 6 ).i? t`' 0k < iU1, M '- 3 .k -Fk . 2'! . SS .. 4 . G r 33 ks. mks( /g4.. 4 Di = L/ 0 . D.To Mile* 72" 7P/ s Moe: (5.1 )'Z) 'Z 1 g y 22.. ac tei Nt a M 51 ' Dk. 6 Go p,8R.i30,3 1t 14 4: SA4;4)r VV w 4. m.51. k" -F,", l9.tt ( /9/4 4 'AA, b , = 0.15' bk 4 L f I e. -. 0.4©-► Cod- oohs • Au. ,1.,te 3 ft 3x G4 C f crIo.d :J1171 Date 12,10 3 Job No. 0 40 Q 2 Checked Sheet a of Lip 2.01 ., I * , 0bll 4 L ro 3,3y -" Ae 0,54 'E vy P.€774' 44. L k Q X34- ; Sxe .1. 0, SS4 - w 3 Si 2- p. 3? 4,;3 j. le VW 2 `. 1.141" . 1 � i ' Px S.GS -�.c Z 10,431 1-s7 M = (.Sg W g , 14.97 M v. 33 k-s-: ) 1,1 $3.3%" 6k-1'��) /018 Gv,vrGs Ccv = 5 g , 12- k o./ 41" I 1 `F I, 23 1"0: Ai i !t. + 14. 42. /"" /► Sel) ?a -y, :. 43. k>1 o 1 1 " =1' ac 2. c9,77 tgA ej}tc s 0, g S' Ck &ci - rt.1 , - -- 4;, x Cootv,/� D . ?t 4-- 0,S 1.21 G��C 1.33 x V/� gU. Dig, : )??Are Comp P g,144 - �`( OF TDKW1l.A -&a 14. 99 kr,E CI APpRDV CP f . C4 -to,/ 1,03 Dk G 1,33 DEC 18 2003 as NuMk� sulLumG - 1 -- jtSION PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D03 -379 PROJECT NAME: LUWA DISTRIBUTING SITE ADDRESS: 1112 ANDOVER PARK WEST DATE: 12 -10 -03 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision #_after /before permit is issued DEPARTMENTS: Buil Div iZ ��]� Public Works ❑ I 7 AV& Fire Prevention © Planning Division ❑ Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -11 -03 Complete [ Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R�TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01 -08 -04 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing sllp.doc 2 -28 -02 P HMl i COORD COPY ,... tis:::.:::,cY;;'ti.s:,•:is�l r .. v =uL' Sw:.YSY�A 4'M .......... F625•052.000 (S/97) State or Washington DEPARTMENT OF LABOR & INDUSTRIES PO BOX 44450 OLYMPIA WA 98504 -4450 F625-052-000 (8/97) ENGINEERED PRODUCTS INC 1033 6TH AVE S SEATTLE WA 98134 Sehi'ae.'riZ071 6 DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS'PROVIDED BY LAW AS CONST CONT GENERAL EXP: DATE ;':';` CC01 ENGINPI013JK 01/01/2004; :EFFECTIVE "DATE. :o4/124.90: ;, ENGINEERED PRODUCTS INC 1033 6TH AVE S SEATTLE WA 98134 ._-. Detach And Display'Certiricaie Detach And Display Certificate REGISTERED AS PROVIDED BY LAW Al CONST CONT GENERAL II REGIST. # EXP. DATE CCO1 ENGINPI013JK 01/01/2004 EFFECTIVE DATE . 04/12/1999 ENGINEERED.PRODUCTS INC 1033 6TH AVE S SEATTLE WA 98134 . Signature Issued by DEPARTMENT OF LABOR AND INDUSTRIES FIRST CLASS JIAII. US POSTAGE. PAID Z1.3 `r1UF , 14% . tctAhlr! 1.) ! PERMIT NO 312 C Receiv OF TUKWILA DEC 2 3 2003 diiiq PERMIT` CENTER 11161111111101d1 • • • Please Remove And Sign Identification Card Before Placing In Billfold site plan easy up luwa distribution floor plan elevation O "A145 s 4' -0" SIDE 1 COMUMN 14 GA THK 12' -0" OR 6' -0" FRONT TYPE A RAC< ELEVATIONS SCALE: 1/4"= 1 1 /2' 14 GA THK ---n FOR 6' -0" (TYP) FOR 12' -0" (TYP) Nt- ( COLUMN STRUT 7/8" T 6 1 /4" 1' FOOT fi { e CN \T\ 3/v6V FLAT , --- 12' - 0" OR 6' - 0 " FRONT TYPE B BRACKET ASSEMBLY -, AS NOTED �. :.o LOAD BEAM SEE V,TES :c 2 3/4" t:E 1/8 V \TYP 14 GA THK UPRIGHT COLUMN HORIZONTAL BRACE I DIAGONAL BRACE (TYP) ?J� BRACKET ASSEMBLY AS NOTED kio • • • LOAD BEAM STRUCTURAL NOTES 1. RACKS ARE MANUFACTURED BY ANDERSON RACK OF SFOCKTON, CA. 2. MINIMUM YIELD (Fy) AN() ULTIMATE (Fu) STEEL STRENGHTS SHALL BE AS FOLLOWS: A) PALLET RACK BEAMS AND COLUMS Fy =55ksi Fu==65ksi B) PALLET RACK BRAC:NG STRUT Fy= =55ksi Fu =65ksi C PALLET RACK BASE PLATES Fy =36ksi Fu =58ksi 3. MAXIMUM RACK LOAD PER LEVEL PER PAIR OF BEAMS SHALL BE: TYPE "A" RACKS: 3,000Ibs FOR THE BOTTOM 2 LEVELS. 5,300Ibs FOR UPPER LEVEL. TYPE "B" RACKS: 3,000Ibs. 4. CONCRETE SLAB IS GIVEN AS 5 1/2" THICK WITH Fc' =2,500psi. 5. ALLOWABLE SOIL BEARING IS GIVEN AS 1,000psf FOR GRAVITY LOADS. 6. TIE-DOWN ANCHORS SHILL BE HILTI KWIK BOLTS OR EQUIV. USE: 2 -1 /2 "0x4 1 /2" ANCHORS WITH A 3" EMBEDMENT PER BASE PLATE. SPECIAL INSPECTION IS NOT REQUIRED. 7. POST LOAD SIGNS NOT LESS THAN 50 SQUARE INCHES IN AREA DEPICTING THE DESIGN CAPACITY AT CONSPICUOUS LOCATIONS. 8. IF ANY DISCREPANCY OCCURS, CONTACT THE ENGINEER FOR CLARIFICATION. a Ioaes arp OD c 1 C py,, 411--Ylq