HomeMy WebLinkAboutPermit D03-392 - SOUTHCENTER MALL - KING COUNTY LIBRARY SYSTEMKING COUNTY LIBRARY SYSTEM 1115 SOUTHCENTER MALL D03 -392 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049023 Permit Number: D03 -392 Address: 1115 SOUTHCENTER MALL TUKW Issue Date: 02/19/2004 Suite No: Permit Expires On: 08/17/2004 Tenant: Name: KING COUNTY LIBRARY SYSTEM Address: 1115 SOUTHCENTER MALL, TUKWILA WA Owner: Name: 3G SOUTHCENTER LTD Address: 25425 CENTER RIDGE RD, CLEVELAND OH Contact Person: Name: DANIEL GERO Address: 1050 N 38 ST, SEATTLE WA Contractor: Name: MIKE WERLECH CONSTRUCTION INC Address: 4522 49TH AVE SW, SEATTLE WA Contractor License No: MIKEWCI044LL DESCRIPTION OF WORK: TENANT IMPROVEMENT COMBINING (2) EXISTING LEASE SPACES WITH RENOVATION OF FINISHES, MECHANICAL, PLUMBING, AND ELECTRICAL SYSTEMS. Value of Construction: $ $100,000.00 Fees Collected: $1,644.19 Type of Fire Protection: SPRINKLERS /AFA Uniform Building Code Edition: 1997 Type of Construction: II -N Occupancy per UBC: 0023 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: N Storm Drainage: N Street Use: N Profit: N Water Main Extension: Water Meter: doc: Devperm N N DEVELOPMENT PERMIT Private: N D03 -392 Phone: Phone: 206 - 675 -9151 Phone: Expiration Date:04 /13/2005 Public: N Non - Profit: N Public: N Printed: 02 -19 -2004 Signature: Print Name: doc: Devperm City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: _, \14% D03 -392 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this per i it does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constru •nor he performance of work. I am authorized to sign and obtain this development permit. Date: Z' / —0 `( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printed: 02 -19 -2004 :: �ni.0 Y. e....:: iaR:+ iki+ 51'itni}+'r..:fi�diiYiJUW...i� dig e • --__ '.i�]Lit ,. City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049023 Permit Number: D03 -392 Address: 1115 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 12/23/2003 Tenant: KING COUNTY LIBRARY SYSTEM Issue Date: 02/19/2004 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206 -835- 1111). 4: All mechanical work shall be under separate permit issued by the City of Tukwila. 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 7: Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 8: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 9: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 10: There shall be no occupancy of the building(s) until the final inspection has been completed by the Tukwila Building Inspector. 11: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform Building Code and the Washington State Ventilation and Indoor Quality Code, Chapter 51 -13 WAC. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 14: Maintain fire extinguisher coverage throughout. doc: Conditions PERMIT CONDITIONS 15: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 16: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) D03 -392 Printed: 02 -19 -2004 z _ 1.: � QQ � JU O 0 U 0 CO 111 J I = -' CO u_ w 1I w w d = W z I- 0 z 1— LU U 0 O - 0 1— w w O tJi = O z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 17: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) 18: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) 19: Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1003.2.8.4) 20: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. 21: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13- 4- 5.5.3.1) 22: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 23: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 24: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 25: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) 26: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 27: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 28: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Conditions Signature: Print Name: D03 -392 Date: 2- — / 1 —42 Printed: 02 -19 -2004 z H z c w -J C-) 00 U) 0 N W J H u w w w = w z z0 gui • Ll U O — O I— w W IL 3 z W U = 0 z CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100. Tukwila, WA 98188 ("63 S ou-k{A. Site Address Tenant Nam roperty Ow rs Name: V, -ut.t7 (,0 Mailing Address: Name: T)ts1.11L31 ( 7 1 1 -19 Mailing Address: 1 o S o iU. "7,9, 4-e-s- St 0 V aw\A ' s kcs (war,: ch • s ct_v-e-QA- E-Mail Address: A G Company Name: Company Name: Mailing Address: Contact Person: E-Mail Address: Contact Person: E-Mail Address: IV) Contact Person: E-Mail Address: Contractor Registration Number: **An original or notarized copy of current Washington State S thcs Prre-e,* 5 17)cvw; 5c-t_ frxX Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** FL' 19 Artt..4rt, King Co Assessor's Tax No.: "tc.S oFctcor k -QtA s 3'( cl-rf •Tvettott-p Suite Number: Floor: City Day Telephone: 7-t 101 5 , 9 City Fax Number: -10 .5 - 9 Mailing Address: State City Day Telephone: Fax Number: Expiration Date: 2J25 04 - New Tenant: ID .... Yes El ..No State 9( 03 Zip Zip Contractor License must be presented at the time of permit issuance** _ (Ai A- State City Day Telephone: '1-06 . 61S. "( G Fax Number: "?,.? c„ 1 • 5 v Zip Company Name: Mailing Address: State Zip City Day Telephone: Fax Number: Valuation of Project (contractor's bid price): $ 07 / e515 Scope of Work (please provide detailed information): T tt nn \ I 4.31--tar r i' r Will there be new rack storage? [J ..Yes p.. No \applications \permit application (3.2003) 3/2003 • Page 2 ptnek, • C Existing Building Valuation: $ d, If "yes ", see Handout No. for requirements. Provide:All•Building Areas.in,Square Footage Below "FFloor' 2 3`tl'Float Floors: Basement Acces Strticttu Attached Garage Detached Garage Attached Carport Detached Carp Covered Deck :Uncovered Deck • Existin 292';• 4 sc- .54 s c' Addition 'to Existing ;Type ;of. onstructton -per UBC , (IN Typ of Occupancy per UBC PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 ....Yes 0 ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: R.. Sprinklers pf..Automatic Fire Alarm []..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ..Yes ..No If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. �c Q s Y.tu :!. ;M1:w:i?:� ii l G ^014t Scope of Work (please provide detailed information): lease refer to'Public Works Bulletin #l:for fees 'and estimate'sheet Water District ❑ ...Tukwila ❑... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila 0... ValVue ❑ .. Renton ❑ ...Seattle ❑ ...Sewer Use Certificate 0... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water \applications\permit application (3.2003) 3/2003 ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line „ Call before you Dig: 1- 800 - 424 -5555 „ ❑ ...Permanent Water Meter Size... 2 I WO# ❑ ...Temporary Water Meter Size.. 11 WO# ❑ ...Water Only Meter Size I 1 WO# ❑ ... Sewer Main Extension Public Private ❑ ...Water Main Extension Public Private ❑ .. Highline Page 3 ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Renton ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ .. Maintenance Agreement(s) ❑...Hold Harmless FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: ❑ ...Sewer ❑ ...Sewage Treatment Day Telephone: City State Zip Day Telephone: City State Zip wistKS. r. W�77 L'+ it c! RAir. 1�� ,.,""!4sr3r..:a7a::.Yiirsv'sY Unit Type: Qty : Unit Type ' Qty Unit Type : Qty . .Boiler /Compressor Qty:; Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler 3 -15 I'IP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended /Wall/Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig /Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm /Ind •1EANI MECHANICAL CONTRACTOR INFORMATION Company Name: "rT3D Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .... rj Commercial: New ....0 Replacement .... 0 Fuel Type: Electric 0 Gas ....ID Other: Indicate type of mechanical work being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: V-3Qi? A Print Name: le--e).1 y S o ,�,, ,„ r 0-9, U S Mailing Address: o ' 'N Day Telephone: - 2.c) S. 51 S 1 City Date: c&Lc-. 2303 State Zip Date Application Accepted: 12 -13 -05 Date Application Expires: 6 -- Z3 -a Staff Ztials: �J�f - �pp�� � iV ( KP s. ,fir! rm ?n fli s a r < :n.., r x.. ; ,.a wr., , 7.re.r., W ^7,V!t Y L�R1'�T''R5. .•�` 1n�5`rgN"R�tl�i ���rt���`'.�?3,'� ��. 71 �ab. Y7 r.' ?fi'el'iY n — � ; Y! r ��:.�f�:ti' Nicnt+.�l+pSritKOtias.'t�.r i t•."" „ +t. P:t: ” k- .$k City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 2623049023 Permit Number: D03 -392 Address: 1115 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 12/23/2003 Applicant: KING COUNTY LIBRARY SYSTEM Issue Date: Receipt No.: R04 -00195 Payment Amount: 998.25 Initials: SKS Payment Date: 02/19/2004 08:40 AM User ID: 1165 Balance: $0.00 Payee: MIKE WERLECH CONSTRUCTION INC TRANSACTION LIST: Type Method Description Amount doc: Receipt Payment Check 7167 998.25 ACCOUNT ITEM LIST: Description BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 Account Code Current Pmts 993.75 4.50 Total: 998.25 7950 02/20 9716 TOTAL 990.25 Printed: 02 -19 -2004 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049023 Permit Number: D03 -392 Address: 1115 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 12/23/2003 Applicant: KING COUNTY LIBRARY SYSTEM Issue Date: Receipt No.: R03 -01549 Payment Amount: 645.94 Initials: BLH Payment Date: 12/23/2003 12:27 PM User ID: ADMIN Balance: $998.25 Payee: SNYDER HARTUNG KANE STRAUSS ARCH RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 1663 645.94 ACCOUNT ITEM LIST: Description doc: Receipt PLAN CHECK - NONRES Account Code Current Pmts 000/345.830 645.94 Total: 645.94 '5922 12/23 9716 TOTAL 645.94 Printed: 12 -23 -2003 Proj .r. ct: t , ; �� 16Y� of sp ction: Type - �c /t l� Addr sr Date Called: 2 / Special Instructions: • Date Wante 1 6091 ino 7 a.m. Requester: � / Phong,No_ Co - c) 1 I k I L t INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ‘ p \ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: 3 , /05/ ctor: 1 //C J A A A-�, I W J 47.00 REINSPECTI • N FEE REQUI5ED. Prior to inspection, fee must be paid at 6300 South nter Blvd., Suj a 100. Call to schedule reinspection. Receipt No.: Date: Pro'e t: Type of Inspection: Address: 1kts G• C. mA ►► Date Called: S -zN - Special Instructions: Date Wanted: a.m. Requester: "'—"- Phone No: a aef, -s -' -/79V INSPECTION NO. INSPECtION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1o3 - 3Cz.- PER 206)431 -3670 '"fi per applicable codes. El Corrections required prior to approval. COMMENTS: L i O r' K6 Insp • ctor: Date: ? 2 7 $47.00 REINSPECTION I REQUIRED. Priof to inspection, fee must be p id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. R'ec ipt No.: Date: Pr a t: Type of Inspe,lon: riz ,/ y , Addles . C ' /174 Date Called: . -- of Jo v Spbcia Instructions: Date Wanted: a.m. Requester: Phone No: (MI P -' 9 7 / -'. 1 INSPEC ON NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspector: $47.00 REINSPECTIO paid at 6300 Southcen Receipt No.: INSPECTION RECORD Retain a copy with permit Date: PERM (20 )431 -3670 • Corrections required prior to approval. / 4 / / /-4 p„, )„,/ Dates_ EE REQUIRED. Prior to inspection, fee must be r Blvd., Suite 100. Call to schedule reinspection. COMMENTS: � / , c ( .Oh e . , Type of Inspectiod J , ._.3 / 4 pbio / 1,- ,,, ed-'! ,j e . / / // C / " 2 Date C Iled: L — 1 _D _ 1'45- o.-- /, Zerle 04 , , j t/ 7_ �'r' , _ �r�'>!..P d �c,.✓�+u- , fit 'r�� led 4%6, X. 1' _ 3 2' per+ : RegT1'ester. f)4_ L(' /6 C..4 e ', s- 7,-/../ r -e.. r Phone. : /7 /.) ,-,2S -- Al .e..i/ l./ 4 4 2, . as 4.--- ,e i , c..'.. - ./ 4.7 /.. Or- . 4le Z?..el f 4% , 'A./ - '60 SWI Jr, / 1a .2 1r z., _ er ri 0 -1-, r'e /', e s-e _ AGe.x -. Q.�' ems`` S tat.... Yt7i/ * I—, // 7 2 7 — _,--psze7240...0..),I, r 0 g ' 44wf,e/1 i J tf 7 . . / ■-5 --- 1 t Project: d t � z 6P Type of Inspectiod J , (_..ct5 6 e . / / // C / " 2 Date C Iled: L — 1 _D _ i, ions: Date' anted: f 7 a.m. RegT1'ester. f)4_ L(' Phone. : /7 /.) ,-,2S -- /96 INSPECT NO. CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Inspector: INSPECTION - RECORD Retain a copy with permit Corrections required prior to approval. Date: El $47.00 REINSPECTI N FEE REQUIRED. Prior to inspection, fee rfiust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: (206)431 -3670 COMMENTS , �,( .do// lx/ -° ,� -'/ 4 Type of Inspecn: 4-071<kie9,4 i'l-r<e. S-- e .-ez .... ; 5 / 054,. , ,25 0 12t9'--- 6 Lt/' A-70 S / ^ l�fJ.e.-e, 7f f Me? I/ /— / ir2?- e.�,4e- Wes.- 1 S 0:..� P /! /n t../2 ✓i! 4 €/94- .6d f, ke / / / V ;J 7 /f i • c- �.- '/-` 3 F � ' 41 1�,, Lr) S�fr � (,0 /,G, t ‘(, c e __ '-1.7u l/ s , n , c d---, c_i-o- c,--,7)-.1.-- d st t -ry 4-J 1 S l u a A 4:Q, ( se( L.4--) r-- ..:1/ ‘._.../ /1 A Pr ect: Type of Inspecn: 4 Ad ress: \t \'S -' Date Called: D�f .Mall Special Instructions: 7 30 41°424:--. Date Wanted , aim j P.m. Requester: Phone No: ;INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter 'Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. f)r)?' PERM (206)431 -3670 Corrections required prior to approval. Inspecto 4 Date: j,., / ., 9_ El $47.00 REINSI CTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ProjeP / 1 Type of Inspection: /' e-2/ i,-/,_, -3_, Address: �` �i / ) i.," Date Called: ,5,- Special Instructions: Date Wanted: Requester: Phone No: Yi�2: rd�t` :,d7`v�:::.K!:tr;yw"ti:t'C2 .. " ;• .r. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: y $47.00 REINSPECTION F REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: ! P YI t„ ` ,_,J, k,, _=S "iced Ct,r l f C'ir (' e -,,D(, f/ / r / //5 S.C, Mq // Date Called: r �(q_ L Special 1 structions: • 7 - 2,..--) 4-Weyr Ltf 0 c S P i J s d-t., , } C✓ ads ,5,-, ,' 4 a. Phone No: ( /0 ( ei.." /I ,ems.- ,-, Projec L'» Type of Inspection: - / //5 S.C, Mq // Date Called: r �(q_ L Special 1 structions: • Date Wanted: , ' z f.7 0 a.m. p.m. Requester: • Phone No: k.. INSPECTION RECORD Retain a copy with permit INSPECTI• N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. (206)431 - 3670 VKCorrections required prior to approval. Inspector Date: �1-0C $4 .00 REINSPECTION(F E REQUIRED. Prior to inspection, fee must e paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • Pct: �; ` � Type Inspection: • � t I A dre s: i s.C , WU(� I nstr C Called: LI 1it ° Special uctions: 9. t i I 1.� Date Wanted: ted: an i 1 1 1x/04 Requester->, Phone C 1 . 7 I 1 / 8 L INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PER. j !0 (206)431 -3670 Corrections required prior to approval. , 14 COMMENTS: _ � ,hA re .e4!."4-4; / El $47.00 REINSPECTION F REQUIRED. Prior to inspection, fee mustlbe paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: _sp COMMENTS: D ✓)2cr'f/,J / j,9 / WOV /- -' /n/6 604* - (. d 744,7`.. , 21 " 72 i 7 U4t G(II' / Type of In _:,,I,,,�1/65 / 4 'el: 1 I 71 KI-7 ," ct /4 -iii /n,7 .) c i _.- �/rY" ,'� 'l7h ') /(►,a 1 ., ' -� <y --/ - vim/ 7 ,gel . ' ,577)0 PeA f /�' M.W1 a,ra 1Q.JUYt 04 -040 6 tP fad d 6 -1 1 -0 `- I Special Instructions: Prejest: t -I i `./ t.._) tau t. /1-'1 y Type of In _:,,I,,,�1/65 / 4 Add a s• �r /�' Date Called: / Special Instructions: Date Wanted: a.m., Requester: ��_ Phone No: zS" 7614 47 // 4 • 3 �a!: rY �.?,.". 3 .✓t"�i.J:i<'Cic;:,s�.fi�A'4C:d I ti�yi:���i:~:::w`'.'�Si2 ji.. u:a'., i" i� `S'Aia:�..:�;:r`.::u':c::;:i6. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Sou thcenter Blvd., #100, Tukwi a W/� 98 188 i ter / rio3- 392. (206)431 -3670, Approved per applicable codes. ❑ Corrections required prior to approval. ctor: /044_, >0-1-41e.f-tial Date: ,.� /(5706/ $47.Q0 REINSCTION FEE RE UIRED. Prior to inspection, fee must be paid at 6300 outhcenter Blvd., Suite 100. Call to schedule reinspection. p:. Receipt No.: Date: Pr� c �i Type�of Inspection; P n l }.))MZtd res Ad s: & A.1 Date Called. Special Instructions: Date Wanted: � j a / p.m. Requester: Ph a o: 51 ( 17 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector:' INSPECTION RECORD Retain a copy with permit A O. (206)431 -3670 pproved per applicable codes. D Corrections required prior to approval. COMMENTS: Date: a-02-1 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: 7 Ciiy of Tukwila Fire Department Address 1 1 l ."- ... rn•07 \7 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM .Project Name l jNJ i CO- I r 1 /1 to _.Retain current inspction schedule \' Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: `/ Fire Alarm: /W/ Hood & Duct: Halon: ii Monitor: Pre -Fire: Permits: Authorized Signature FINALAPP.FRM Rev. 2/19/98 J Permit No. Steven M. Mullet, Mayor Thomas P. Keefe, Fire Chief Date Suite # G, T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 Project Info Project Address �cyrlr� 4.4531,A ,���.� r r - t L S C w (check appropriate box) i2.2=y• 0 3. 1 (1 5 Sc "mein.". S& 5C4-t l 7 ye. '°JJF-11✓ E'C 0. o For Building Department Use 'N I ..k.. .fit f v.) Ac 0.3 W /ft2 Applicant Name: c A►i 9 , 11t-'5 0.2 wile Applicant Address: i v%e N o/„.t,...t 3'� Sr c e Applicant Phone: (ZCG,,,) Gel 5 _' (5 0.2 we Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts Alteration Exceptions • No changes are being made to the lighting (check appropriate box) Less than 60% of the fixtures are new, and installed lighting wattage is not bean. increas- . • Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts ProptibeBMIT C Allowed Watts x ft (or x If) {�,, S& 5C4-t l 7 ye. '°JJF-11✓ E'C 0. o 0.2 W/ft2 Covered Parking (reflective paint) 0.3 W /ft2 Open Parking 0.2 wile 6 #f"'r 2 6 2 aUt Outdoor Areas 0.2 we Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 'Fri maximum i-uitowed Lighting wattage (Exterior) -- �o sL -1 c—#- Location Description Allowed Watts per ft or per If Area in ff (or If for perimeter) CIO OF TJKWiL4 APPRO�IFII Allowed Watts x ft (or x If) {�,, Covered Parking (standard paint) 0.2 W/ft2 Covered Parking (reflective paint) 0.3 W /ft2 Open Parking 0.2 wile 6 #f"'r 2 6 2 aUt Outdoor Areas 0.2 we n S ; ; } 'Fri Bldg. (by facade) 0.25 W /ft _. .__ _ Bldg. (by perim) 7.5 W /If _' ' ; ;;. `..•i�' L , II�:�i '7J✓f� Note: for building ex erior, choose either the facade area or the perimeter method, but not both) Total Allowed Watts ubr o at/ Wts Lcto itr ecito itrs Fxue Pooe oa rpsd Wts my nt ece oa loe at o xeir Ttl Pooe at CITY OF TUKWILA Lighting Summary LTG -SUM 2001 Washington State Nonrosidenllal Energy Code Compliance Forms Project Description New Building 0 Addition )1 Alteration Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Maximum Allowed Lighting Wattage (Interior) Location (floor /room no.) 'Occupancy Description t�A� �. b-•1 (i o ` �G ~ r . �. % b 4(' 0 ' �.r'. t-tr. ) Allowed Watts per ft2 "' I.5 FiLE COPY Area In fe ►t 21 . t7 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts Allowed x Area 16 35 Cps.ts Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the fMMGIfFEIVED table in the NREC Technical Reference Manual may also be used C Y OF TI JKWII A 2. Include exit lights unless less than 5 watts per fixture. Proposed Lighting Wattage (Interior }ist all fixtures. For exempt lighting, not exception and leave Watts /Fixture blank. DEC 2 3 2003 • 14-1.1, Buildin • Division June 2001 • KJM p g g g ENTER Use' LPA` (W /sf) Use' LPA` (W /sf) Painting, welding, carpentry, machine shops 2.3 Police and fire stations' 1.5 Barber shops, beauty shops 2.0 Atria (atriums) 1.0 Hotel banquet/conference /exhibition hall" 2.0 Assembly spaces', auditoriums, gymnasia', heaters 1.0 Laboratories 2.0 Group R -1 common areas 1.0 Aircraft repair hangars • Cafeterias, fast food establishments' 1.5 1.5 Process plants Restaurants/bars' 1.0 1.0 Factories, workshops, handling • 1.5. • Locker and /or shower facilities 0.8 Gas stations, auto repair shops 1.5 Warehouses ', storage areas 0.5 Institutions . 1.5 Aircraft storage hangars 0.4 Libraries' .. Nursing homes and hotel /motel guest rooms 1.5 1.5. Retail retail banking Parking garages 1.5 See Section 1532 Wholesale stores (pallet rack shelving) 1.5 • Mall concourses • 1.4 Plans Submitted for Common Areas Only' Schools buildings (Group E occupancy only), school classrooms, day care centers 1.35 Main floor building lobbies' (except mall concourses) 1.2 Laundries 1.3 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) 1.2 CITY OF TUKWILA Lighting Summary (back) LTG -SUM 2001 Washington Stale Nonmsldontial Energy Code Compliance Forms Prescriptive Spaces Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Occupancy: 0 Warehouses, storage areas or aircraft storage hangers • Other Lighting Fixtures: 0 Check here if at least 95% of fixtures in the space meet all four criteria: 1. Fixtures are fluorescent, non - lensed, with only one or two lamps, and 2. Lamps are T -1, T -2, T -4, T -5, T -6, T -8 3. Lamps are 5.50 Watts, and 4. Ballasts are electronic ballasts 5. Exit lights < 5 watts /fixture 6. Screw -in compact fluorescent fixtures do not qualify TABLE 15 - Unit Li Power Allowance (LPA Footnotes for Table 15-1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Sectiop 1512 for exempt areas. • 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Includes pump area under canopy. 7) In cases in which a lighting plan is submitted for only a portion of a floor, a Unit Lighting Power Allowance of 1.35 may be used for usable office floor area and 0.80 watts per square foot shall be used for the common areas, which may include elevator space, lobby area and rest rooms. Common areas, as herein defined do not include mall concourses. 8) For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot. 9) For indoor sport toumament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per square foot. 10) Display window illumination installed within 2 feet of the window, lighting for free - standing display where the lighting moves with the display, and building showcase illumination where the lighting is enclosed within the showcase are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, Indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. w Buildin • Division June 2001. KJM Cu "ti,u' tLM. �. �. . +.g1+.R- "W'P1.i. �tmOnti._;day_ Project Info Project Address 40 ..., cat _ f (, t. 490 N f°%e fsate ( • 0 3 I 9 S-0 WTI-1 Govt. L itA.O,,."` si 1 For Building Dept. Use 11) v-v., ll.-A W P' Location of Service 1 Applicant Name: 5 ‘ . - Applicant Address: ' o se, 1 ,1. . ei d% 5erperr Applicant Phone: (2.e a ) 6 ,- / G..... 9/5'1 Fan Equipment Schedule — t -yk 51 a CC Equip. ID Brand Name Model No .1 CFM si 1 HP /BHP Flow Control Location of Service Location Cooling Equipment Schedule - ex L sr t .-1( - a , -.M o ±,.J . Equip. ID Brand Name Model No . Capacity2 Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV3 Location Heating Equipment Schedule — t i c t s rl r., cc - ra f V , Equip. ID Brand Nam& Model No . Capacity2 Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiencv CITY OF TUKWILA Mechanical Summary MECH -SUM 2001 Washington State Nonresidential Energy Code Compliance Forms Project Description I Briefly describe mechanical systen type and features. Includes Plans Compliance Option f■G pi F---t C Srt •.a & -tx0 drwo ti. . ( 12 v s ( rJ & (-2) 6?« ' r r✓ & 'f av ' T Z v L,, FILE COPY Include documentation requiring complia g wit r lit fq �rr1 1 teal t8pprovals ar 3 5jCt tO errnr S and e missions a �tpiiuv(3 Of 0 Simple System O Complex Syste ,,, • • 3 - ,p Systems Analysis ..� o ,0 l� C'1 ST �+ (See Decision Flowchart (over) for qualifications. Usq.stiparate MECH -SUM for simple & complex systems.) lc '`-i r0;;. . Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the 1 plans. For projects without plans, fill in the required information below. 1 1f available. 2 As tested according to Table 14 -1, 14 -2 or 14 -3. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). CITY OF TUKWILA APPROVED JAN 2 0 2004 AS WALL) �3UILD - IING i�i�' , I< N Building Division -7 -c. June 2001 - KJM RECEIVED CITY OF TIJKWtI A DEC 2 3 2003 PERMIT CENTER r rxr , ... rvwor,. n °�x� rp., .i.vr., +.. r,. .,. . «x!r:...,... -�.�• -e. .. .. . *r..ar� System Description See Section 1421 for full description If Heating /Cooling or Cooling Only: • Constant vol? Split system? • Air cooled? • Packaged sys? • <54,000 Btuh Economizer included? or 1900 cfm? • • of Simple System qualifications. If Heating Only: • <5000 cfm? • <70% outside air? CITY OF TUKWILA Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating/ Cooling Heating Only Complex Systems Yes Yes). or Cooling Only Reference Section 1421 Yes Yes Yes Yes Yes Reference Section 1423 Simple System Yes Mowed Reference Section 1420 Yes No-0 NO-0 Building Division 6 f ` ( Reference Section 1430 Refer to MECH -COMP Mechanical Complex Systems for assistance In determining which Complex Systems requirements are applicable to this project. Si 05/05/2004 10:00 2066759150 SHKSARCHITECTS PAGE 01 w D M E M O 0 F A X 0 T R A NS M I T T AL Dear Mr. Nelson, To Ken Nelson City of Tukwila 6300 Southcenter Blvd. Tukwila, WA 98188 From Daniel Gero Date May 04, 2004 Protect King County Library, Connection at Southcenter Re: Exiting requirements cc: Dale Brickman, KCLS (425) 369 -3310 File Fax number (206) 431 -3665 Total pages 1 This letter serves a record of telephone discussions regarding requirements for final acceptance of the means of egress for the King County Library Connection at Southcenter. On Monday, May 3, 2004, Daniel Gero and Ken Nelson spoke twice to review the means of egress as designed and built, the City of Tukwila Field Inspector's findings and requirements, and finally, the conclusion as to what would be acceptable. The following summarizes that discussion: 1. On Friday, April 30, the Field Inspector determined that two exit doors are required. He determined that the west mall entrance can not be permitted as a designated exit door because its operation mechanism does not conform to exit door requirements. The man door to the east could be designated as an exit if the door swing was reversed to swing in the direction of exit travel. The south mall entrance is acceptable as a designated exit as it currently exists. 2. Gero cited UBC 1003.3.1.5, which states, "Exit doors shall swing in the direction of the path or exit travel where the area served has an occupant Toad of 50 or more." Both Gero and Nelson agreed that the occupancy of the area served by the east man door is less than 50. 3. Nelson stated that the swing of the east man door is acceptable as installed, swinging into the Reading Room, against the direction of exit travel. 4. Nelson stated that only one exit is required. He further stated that any exit signage installed above the east man door should be removed, so that only the south mall exit shall be a designated exit. We will instruct our client to act according to the discussions described above. If your understanding of our discussion or conclusion is In any way different than this record, please contact us immediately so that we can Instruction our client accordingly. Thank you. 1050 Nom 38^ Sbee4 Sa a Waahi gb n 98103 Tel 206.675.9151 Fax 206.675.9150 www.shicarcNiecis.00rn RECEIVED CITY OF TUKWILA MAY 1 0 2004 PERMIT CENTER �3- 3 ere_ 05/05/2004 10:00 2066759150 W z CC C3 Z V w 1- U d Dear Mr. Nelson, SHKSARCHITECTS PAGE 01 M E M 0 0 F A X O T R A NS M I T T A L To Ken Nelson City of Tukwila 6300 Southcenter Blvd. Tukwila, WA 98188 z From Daniel Gero tu o!2 Date May 04, 2004 0 CO Project King County Library, Connection at Southcenter w = U LL Re; Exiting requirements uJ 0 Cc: Dale Brickman, KCLS (425) 369-3310 g File to Id Fax number (206) 431 -3665 �' w z H Total pages 1 Z O lil in U D This letter serves a record of telephone discussions regarding requirements for final acceptance 0 I— of the means of egress for the King County Library Connection at Southcenter. On Monday, w w May 3, 2004, Daniel Gero and Ken Nelson spoke twice to review the means of egress as F- H designed and built, the City of Tukwila Field Inspector's findings and requirements, and finally, "-- z the conclusion as to what would be acceptable, The following summarizes that discussion: 11 u) U = O ~ 1. On Friday, April 30, the Field Inspector determined that two exit doors are required. He determined that the west mall entrance can not be permitted as a designated exit door because its operation mechanism does not conform to exit door requirements. The man door to the east could be designated as an exit if the door swing was reversed to swing in the direction of exit travel. The south mall entrance is acceptable as a designated exit as it currently exists. 2. Gero cited UBC 1003.3.1.5, which states, "Exit doors shall swing in the direction of the path or exit travel where the area served has an occupant Toad of 50 or more." Both Gero and Nelson agreed that the occupancy of the area served by the east man door is Tess than 50. 3. Nelson stated that the swing of the east man door is acceptable as installed, swinging into the Reading Room, against the direction of exit travel. 4. Nelson stated that only one exit is required, He further stated that any exit signage installed above the east man door should be removed, so that only the south mall exit shall be a designated exit. We will instruct our client to act according to the discussions described above. If your understanding of our discussion or conclusion is In any way different than this record, please contact us immediately so that we can Instruction our client accordingly. Thank you. 1050 Nash 38 Steel Seaele Washington 98103 Tel 206.6759151 Fax 206,675.9150 traw.shksarchltele.com RECEIVED CITY OF TUKWILA MAY 1 0 2001 PERMIT CENTER 4:•A d., ... . i,: f:'. �v.... :cR_...,.4.s!.tt�..o..,in';'.., u+a.is�.xd`.u::1'. Sidi- e'iti • a:w z 05/05/2004 10:00 2066759150 W Z to w z U cc D M E M 0 0 F A X 0 T R A NS M I T T AL Tukwila, WA 98188 z From Daniel Gero 1 W 2 Date May 04, 2004 00 Project King County Library, N D Connection at Southcenter 2 Re; Exiting requirements W 0 2 I- cc: Dale Brickman, KCLS (425) 369 -3310 File co = Fax number (206) 431 -3665 �' W z = Total pages 1 Z F- W W Uin N This letter serves a record of telephone discussions regarding requirements for final acceptance 0'-- of the means of egress for the King County Library Connection at Southcenter. On Monday, = W May 3, 2004, Daniel Gero and Ken Nelson spoke twice to review the means of egress as 1 ;- designed and built, the City of Tukwila Field Inspector's findings and requirements, and finally, U. 0 the conclusion as to what would be acceptable. The following summarizes that discussion: U = 0 z Dear Mr. Nelson, SHKSARCHITECTS PAGE 01 To Ken Nelson City of Tukwila 6300 Southcenter Blvd. 1. On Friday, April 30, the Field Inspector determined that two exit doors are required. He determined that the west mall entrance can not be permitted as a designated exit door because its operation mechanism does not conform to exit door requirements. The man door to the east could be designated as an exit if the door swing was reversed to swing in the direction of exit travel. The south mall entrance is acceptable as a designated exit as it currently exists. 2. Gero cited UBC 1003.3.1.5, which states, "Exit doors shall swing in the direction of the path or exit travel where the area served has an occupant load of 50 or more." Both Gero and Nelson agreed that the occupancy of the area served by the east man door is less than 50. 3. Nelson stated that the swing of the east man door is acceptable as installed, swinging into the Reading Room, against the direction of exit travel. 4. Nelson stated that only one exit is required. He further stated that any exit signage installed above the east man door should be removed, so that only the south mall exit shall be a designated exit. We will instruct our client to act according to the discussions described above. If your understanding of our discussion or conclusion is In any way different than this record, please contact us immediately so that we can Instruction our client accordingly. Thank you. 1050 Nonh 38" Sbeel Seale Washington 98103 Tel 206.675.9151 Fax 206,675.9150 www.9tiGanitecis.aom RECEIVED CITY OF TUKWILA MAY 1 0 2004 PERMIT CENTER DEPARTMENTS: Documents /routing slip.doc 2.28.02 ACTIVITY NUMBER: D03 -392 DATE: 12 -23 -03 PROJECT NAME: KING COUNTY LIBRARY SYSTEM SITE ADDRESS: 1115 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after /before permit is issued PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP kw-Get ,92._ Fire Prevention 4] Buildin' +'vision Public Works [ t_ Z Structural lu �y 44-03 Incomplete ❑ APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions DETERMINA • N OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -30 -03 Complete Comments: REVIEWER'S INITIALS: PERMIT COORD COPY Planning 6/1)(-- Division jn -4 Permit Coordinator Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 01 -27 -04 Not Approved (attach comments) ❑ Notation: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: VA Its s= .ta;:: ∎.1'14 a`.:4A4..4%11 4v DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST. CON.T GENERAL r.a r .CC.101 , - .;- :N1IKEWCI Q4/13/2005; EFF DATE 0/13/.1996 MIRE WERLECH CON INC: - .' ' 4522 49TH AVE SW •• SEATTLE WA 98116 F625-052-1101)1807) - 0 7 3 H m C)) 0 z G) m • m z • W J O 0 (.0 0 J = H U) LL w 0 2 u. co w Z � Z� w O i n - • 1— W u. W U= O H z ABBREVIATIONS s L 1 0 NOD A.B. ABV AC ACT ACU ADJ ALT AWN AMNON MD MOLE AT OPMETER POUND OR OR NUMBER EXISTING CENTERUIE ANCHOR BOLT ABOVE AMT CONDITIONING ACOUSTIC COM TILE NM CONDITION UNIT ADJusTAI,E at MISTED FLOOR ALTERNATE MUMMY APPROXI A1EL.Y BUILDING BELOW BORTOM OF CATCH BASIN CEMENT BACKER BOARD CENT CONTROL JOINT CENTERU E COUNG CLEAR CLEAN OUT COLLUTA N OOINCRETE CONDITION CARPET CERAMIC TIE NTS .,r1YMIr .M. ' .IniRyR � Ok DOW OF OM on" ow OMP ON OR OS OW 1r ---�i le - --'1 1 1144■ y1 DOUBLE DEMOLITION DRINKING FOUNTAIN DNI ETER DIFFUSER DIMENSION DISPOSER DOWN DOOR OWNSPOUT DETAIL DISHWASHER 1 EAST IA EACH ICS EXTERIOR COMPOSITE SIDING EXHAUST FAN EJ EXPANSION JOINT IL ELEVATION BBC ELECTRICAL. ELEv ELEVATOR !TIRO EMERGENCY IQ EQUAL Ex! EXPANSION IWP FIBER BOARD PALL FD FLOOR DRAIN FE ARE EXTIMI SUER FF FINISH FLOOR FN FIRE IfYDRANNT FN HASH RR FLOOR F.O. FACE OF FOIC FURNISHED BY OWNER, INSTALL BY CONTRACTOR FOLD FURNISHED BY OWNER INSTALL BY OWNER FR ARE RESISTANT FS FLOOR SINN( ,• ■ SITE/ KEY PLAN imoomoomovall irz OA GALV so al as SW OR WO HP IBC NCMII IOW IOW NT IS se TROP SOUL I.D. TIT .IAN KO JT IQT LAB LAN LAV L10t LOC LT LVL GNJGE GALVIAIMZED GRAB 6118 GLASS GROUND 11141 GRADE GROUTED GYPSUM WALT BOARD HOSE BIBB WOW HOLLOW CLAY IKSON Y UNIT 101117/1000 IWRDWRE MIGHT HOLLOW METAL HOUR HORIZONTAL INSIDE METER INSULATION INTERIOR JAITOR JOINT KNOCK DOWN KRCH II LABORATORY LATINATE LAVATORY LOCKER LOCATE UGHT LAIINTED VENEER UMBER f '04 .E iS. de, 9 . N NA NC NON NT$ NR OA OsS O.C. O.D. OFF OMl6 OPP WITONAL Kamm MEDICINE 1Eip1AIr COMET MOW MANUFACTURER MAIM MEBMOR MISCEUMEOUS MMMiOIE M ASiOIMTY OPENING MOUNTED MEM M LUON NORTH NOT MOBIL NOT IN 03NTRACT NOMINAL NOT TO SOLE NOT RATED O1IERILL OBSCURE ON CENTER OUTSIDE DRIFTER oFFXE OPENING OPPOSITE OT MARRY 11E R w RAD RAMS R• RCP 01 PSI MIPS BLOC R/f1 MI RO Mw 0 OA IC STABILE SECT SS SILT SPEC SG Ss. STA STD STN. STN STOR MCI 006 SNP SYN RESTON BASE REFLECTED CEIING PL* ROOF DRAW Puma REFRIGERATOR RONFOICED RELOCATE REQUIRED RESIUDIT ROOM ROUGH OPENING ROOF MIT RANI WATER LEADER SOUTH SMOKE ALARM SOLO CORE SCHEDULE SECTION SAFETY GLASS SHEET SM�A,JYi SPECIFICATION SQNE STARLESS STEEL STATION STANDARD STEEL STAR STORAGE STRUCTURE SLAB ON GRADE SUSPENDED SYMMETRICAL T, 11P TOM TL 101 11K T.O. TB TV UL WRT uNo VII' w VTR R1 MSC RD WF RID 1WON OW WP WR VA= TNT ,11 SWWWINDO Rabe►,&* TEMPERED TONGUE It GROOVE TELEPHONE TERRAllO THICK TOP OF T'EE STEEL TELEVISION MICA AL UNDERWRITERS' LISORATORB UNLESS NOM) OTHERWISE VINYL. COMPOSITION 11LE MICA VESTIBULE VBIFY IN FIELD VENT THRU ROOF WEST WITH WATER CLOSET WOO MOE amGE WITHOUT WALK OFF MAT WOMEN'S WATERPROOFING WATER RESISTANT WAINSCOT WEIGHT i 0 1 • GENERAL NOTES 1. ALL WORK SIWLI. OE w CONFMINANCE MT1f APPUCALE CODES Mm LOCJI. OWODING RICH INCWOE THE MOST CURRENT EDITIONS OF UE UPC, WC, UNIFORM FIE CODE. AND SA STATE ENERGY COOS. 2. CONTRACTOR SWILL VEINY ALL DIMDI 10NS SHOW ON 1E maim &FOIE COMMON MIN WORK. ANY DISCREPANCIES SWILL BE DROUGHT TO 1!E ATTD1TION OF THE AACIIIECT PRIOR TO MSS ANY CONSTRUCTION TO THE AREA mann DO NOT SCALE ORAIIIINtS. 3. DIVISIONS ARE TO Ha OF STEEL, FACE OF CONCRETE OR FACE OF STUD, UNLESS NOTED 011EKw 4. PMTMO IS AND WALLS NOT MI MS( DI ENSIOIED SHALL. PC LOCATED FLUSH WITH wear WAIL FACE OR WITH REFERENCE TO CE71TERLSE OF COLUMN. 5. PRIOR TO AID DIEING WORK, CONTRACTOR SWILL MR EXISTING COMM AID DIMENSIONS. ANY COMMONS OR DIMON NCON51SID(T WITH THOSE PRESENTED IN TIE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO TIE ATTENTION OF TIE ARCOITECT PRIOR TO STARTING OR CONNING WORK IN DE AREA CONCERNED. 1 COORDI ATE ALL OPERATIONS WITH LANDLORD, SUCH AS AREAS USED FOR *GEM. STORAGE, ACCESS TO AND FROM THE SAE, 111ING OF WORK MD SPECIE CONSIDERATIONS OF THE NOISE OROIONAINCE. INSTALL OUST AND NOISE WIRERS AS REQUIRED TO PROTECT DOSING ADJACENT BUILDING MD OCCUPANTS AID TO M IKAN NI E M R01IENT SMILE TO PERMIT COMM OCCUPANCY OF ADJACENT BUEAPNGSS. 7. PRO DE EVCIONG, 81.O0011G NOD SUMCRNT STRUCTURE IN WALLS FOR SUPPORT= COWERS, CABINETS, BC., AS REQUIRED. 8. COORDIMITE MW PROVIDE REQUIRED PENETRATIONS AID PATCHING W11H ADMIT OWL SUBCONTRACTORS TO SUIT NEW WORK. 9. 10. 11. 12. E sculam WL 633 SOUTHCENTER MALL PARKWAY Tunti ~, Wk 98188 PROPOSED LEASE AREA: SPACES 384 AID 392 VERTICAL DIMENSIONS TIRE TYPICALLY REFERENCED FROM STRUCTURAL SLAB UNLESS NOTED OTHERWISL AT ARE RATED WALLS OR CEILING ASS WHERE PENETRATIONS FOR MECIWNCAL, ELECTRICAL, OR PLIMrIBNNG OCCUR, PRO OE *PROM THROUGH PENETRATIONS FIRE STOP ASSUMES. WI NTAw REQUIRED RATING OF ASSEMBLES. MAMMA DBMS, OR NOTED oats ARE NEW UNLESS NOTED WORM All SHGNAIE PROVIDED SHALL BE AQA COM PLJANT. CHARACTER PROPORTION AND HEIGHT: LETTERS MW NUMBERS ON SIMS SIG SHAH WANE A WIDTH -TO- HEIGHT RA11O HE1 D1 3 NO 1 :1 AID A STROI(E - 1H - TO- -IWGNT RATIO BETWEEN 1:5 MW 1:10. OORACIER AID NUMBERS ON SIGNS SWILL BE SIZED ACCORDING TO THE VIEWING DISTANCE FROM WHICH THEY ME TO BE READ. THE MINIMUM CHARACTER HEIGHT FOR SIGNS THAT ME SUSPENDED OR PROJECTED OVERHEAD ES 3 INCHES FOR UPPER CASE LETTERS. LOWER CASE LETTERS ARE PERM TITER 13. CONTRACTOR TO C00RDPIkTE SCOPE, EXTENT, DIMDISIONS AIO D ACT LOCATIONS OF ME.OWNC,AL MW ELECTRICAL. DEMOLITION WITH ARCHITECTURAL OIrENSHONS. 14. CONTRKTOR SHALL EXECUTE ALL DEMOLITION REQUIRED TO COMPLETE NEW WORK. PROTECT DaSTWG WORK FROM QAMCE PER SPECIFICI110N. pO C1<"� p' . °' A " L. ENE MADE Ta _ IT ourr PRIOR Jr- 1 1 1 �w err •w rt '-• • • �' .� .* I 4 _ • t oLOINO DIVISION. r 7 ''JAE A NEW PNMI suemmM. REMOVE (E) SIGN - MOUNTING BRACKETS TO REMAIN (E) CABLE LIGHT FIXTURE TO BE REEVED DEMOLITION PLAN 1 /11" =I'-0" 0 1 6 • 1 1 1 1 16 FEET DRAWING SYMBOLS (E) ORNAMENTAL TRUSSES TO BE REMOVED, (3 TYP.) (E) MIRRORS TO BE REMOVED, CINB MW FRAMING TO REMAIN, TYP. (6) LOCATIONS REMOVE ALL DISPLAY SHELVING AND BRACKETS tAcE384I SPACE 1115 SOUTHCENTER WILT. SEATTLE, WA 98188 RMNAME Ixxxl RMNAME xxx ©©© (API UUBI NG FIXTURES TO BE (E) CASEIORK TO BE RE.MO►VED (E) ELECTRIC& PHIL TO BE REIKNED GEMPALffinatiOn 1.PRESE.RVE (E) FDASH ON FALLS. PREPARE DAM SURFACES FOR REPAN AID RE -FISH. 2. (E) LIGHT FIXTURES TO BE REMOVED, U.N.O. 3. MIX (E) GW8 AS REQUIRED FOR BL0O RG/ METAL BAICKOIG VSTALLA REFER ELFMVIONS FOR LOCATIONS. 1 1 1 1 1 MALL SECTION BLDG SECTION EXTERIOR ELEVATION INTERIOR EMMONS INTERIOR ELEVATION HAT DETAIL NORTH ARROW . FLOOR TRANSITION ROOM NUMBER VI RASH DESIGNATION • ELECTRIC/ PANEL TO BE RELOCATED (E) WALLS TO BE REMOVED, TYP. REMOVE (E) SIGN U n • 1 • FILE COPY e check aPPrOV o 1 u nderstand that th d o,issions and app violation of any sublst to errors and the Receipt of con. r plops does code or ordinance. la s acknowledged. �. t adopte d e s py o1 approved P tom' f 1 (E) CARPET MD VINYL FLEA RING TO BE DEEIOVED THROUGHOUT (E) STOREFRONT NI SECURRIY DOOR TO REMAIN GIRD BUBBLE WALL TYPE WINDOW NUMBER KEY NOTE FLAG NOTE REVISION DETAIL BORDER SMALL (sue 392 11 L J LJ XXX T.O. XXX 4 a n T.O. XXX 47- 1 � I t_ (E) : DOOR AND FRAME ( F � IXIUREs TOO ROAW1 +i __,__,__ 1 I XXX CENTERUNE PROPERTY UNE MADISON POINT ELEV. NOTE SKETCH NUMBER ALIGN SYMBOL SPOT ELEVATION DETAIL BORDER LARGE cm Of Ttgill A AQPROvE 3 At4 2 4 2Q 04 Aj t*UItU CoIv;Si') 1 I_ 1 \ \I SAWCUT /REMIONE (E) BRICK FO ,,NEW BOOKDROP ' (E) 2'x4' :ACOUSTIC CEILING ALE RIND SUSPENSION SYSTEM TO Ik REMOVED �E) K.D. METAL FRAMES AND Oa TO BE REMOVED (E) core CELNG 10 BE REMOVED (E) ALUMINUM DISPLAY RAIL TO BE REMOVED 1 t1ROU 1iHOU 1. (E) 2'x2' AOOUSIIC CEILING TILE AID SUSPENSION SYSTEM TO BE REMOVED f l� DRAWING INDEX SAE PLAN/COIERAL INFORMATION A1.0 FLOOR PLAN A2.0 REFLECTED CEIING PIM A3.0 INTERIOR ELEVATIONS 411 STOREFRONT ftEIMTIONS A4.0 (Ms 1110.1 MEOWI CIII. LEGEND At GOOK NOTES M1.0 MECIMMMCAL DEMOLITION PLAN M1.1 MECIWiCAL PLAN E0.1 ELECTRICAL SYMBOLS 8 MITIROPAIONS E1.0 ELECTRICAL MOUTON PLAN E2.0 POWER ! COMMUNICATION PIM E3.0 WITTING PIM E4.0 Rim wows PROJECT TEAM SHKS AN CTS 1050 NORTH 38TH STREET SEATTLE, WA 98103 (206)675 -9151 (206)675 -9150 (FAX) CONTACT: DAM GIRO CERRA ASSOCIATES 2505 THIRD AVENUE SUITE 204 SEATTLE, WA 98121 (206)442 -0112 (206)442 -0113 (FAX) CONTACT: O RM BOEHOLT MECEINCILMINEM THE GREE NBUSOI GROUP 1900 WEST MU2KER90N STREET SURE 201 SEATTLE, WA 98119 (206)378-0569 (206)378 -0641 (FAX) =TACT: DAVID OR1G€Y Km COUNTY uBI1ARY SYSTEIrI 960 NEWPORT TAY NW ISSAQUAH, � 98023 CONTACT: KAY JOHNSON WESTFELD CORPORATION 11601 WILSHIRE BLVD. - 12th FLOOR LOS ANGELES, CA 90025 (310)575 -5918 CONTACT. NARK IIGRAMI PROJECT INFORMATION PROCT ADOtRE'SS: 1115 SOUTHCENTER 1# 11 IUKINIA, W. 98188 --MW- 1127 SOUMCENTER MAIN. TUMKWIIA, SA. 98188 ENNECLOWEBN TENANT IhiPRovEmENT COINING TWO DaSTING LEASE SP,cES WITH RENOVATION OF ROES, MECHANICAL, PLUMBING AID U ECTHBCIL SYSTEM. 663 SOUTHCENTER PARKWAY MINA A, WA. 96118 LatijaMMILMILBSCELIMIREft NOT AMIABLE - PROPERTY ADDRESS SUBMITTED IN LEU OF IEORMMTION NOT AVAILABLE FROM ASSESSORS OFFICE AS ADVISED BY COY OF 1UMKI IA BUHLDING DEPTH EVENT. MOUSE; RETAIL •8 infinagtiifit of I EASE M k 2923.54 SF RELIMILEAILISILLIM UBC 1997 WITH WA STATE • ^TTYC)FT( IA DEC 2 3 2003 PERMIT CENTER 1010 tear 3 SHIM 0l Wastailon011101 TT1r01rorrs 1011175.11161 Famide 31111.075.0100 K C vravaidmdglsolstan L S Connection at Southcenter permit set Mew s fir, o.f�: Nt �o►�r.r� SOUTHCENTER 1115 SoWioeiMer Mel Tukwila, WA 98188 22 D.o.ere«, 2003 As Nord Doran eyr. arschnt Oda Sc* rK No. Deli AMrnorls Site Plan E Demo Plan A0.1 1051-03 A • 1 • •■••••• ....,...... ..- ,.. . 1' -8' s 1/4":1'-0* SOUR SURFACE COUNTER TOP 11' -4' SOLID SURFACE COUNTER TOP FLOOR PLAN 0 ' 2' 4' rill1 15' -O' 0 SIAM r o• or (i.) 1 • f r 8 ._ 8 ' 6' SOLD SURFACE COUNTER TOP PATCH / REPMR MB FINISH AFTER WALL/ MIRROR/ SHELVING DEMO, TYP. All LOCATIONS 1 • 0 READING BOX N COLUMN W/ GINS ON MEAL STUDS ALIGN W/ *wee GRID UNE K /60 i 1 u \\,77' t/ i CNILPREN'$ AREA 11 BOX 11 COLUMN w/ GM ON METAL STUDS NV BOTTOM EDGE OF (E) PAPER rows HOLDER IS 40 OrepSiss s 24' AFF 5'-0' OIA l ! IKEK RON l� r 6' JAVElJI 9' -1 1/2' 3' -8' TELECOM NORTH 29 1/2' TO e.o. ( SINK, 34' TO T.O. (E) SN( (E) TOILET UD 5 19 1/2' AFF Vao • N_ - v BOOK DROP N P(W . 1 - (E) TREE RANTER • 0 _� ..� .....� _ �J 1 N 0 41,40041,444, filervibirS L4410 hrM 1," CM OF TURALA APPRUv0) JAN 202g' iRt�E+vE. ...,• DEC, 2 ;i 2003 ►?ERMII CENTEp toOlivJ 1060 Nom 81Ih 011est Wadinglon 11101 TMlpiww 2(18.1175.0151 Paoli* i.S 8.01110 wire iderdilsdi aom K C L S Connection at SouUxenter permit set SOUTHCENTER 1115 SoWioenler Mal Tukwie, WA 96188 Drawn by: lay Chalet 'MAL_ 22 DOCOMbir, Suit No. DMA Rends W Floor Plan A1.0 r • 411.1%. • , ..- .,....- .,w... ,....... w...�,...,� PERFORATED ALUM PANEL SOFFIT ON METAL FRAMING 0 (E) GWB SOFFIT f EQ. 4' -0" TYP. V E0. U X _— GMIB SOFFIT • 9' -Q' AFF, FLUSH W/ (E) SOFFIT, ul J GYM SOFFIT 0 +9' --6" AFF REFLECTED CEILING PLAN � i 1/1."21'-0" r 1-4 8' -0' (E) SPRINKLER SYS151 TO REMAIN (E) GALVANIZED ILEX SARK DUCT ----0 13 DISPLAY UGHTING, TYP. 1 REFER TO ELECTRICAL DRAWINGS FOR UGHTING FIXTURE SCHEDULE AND ENERGY CALCULATIONS 1-4 • 8'-0" 8'-0' 1 • (E) STEEL JOISTS • 0 • 0 0 (E) GWB C 1LN; (E) SPRINKLER HEAD (E) 50 CFM CEI.MNG FAN GWB SOFFIT • 10'-0' off (E) EXTERIOR SOFFIT OPEN TO STRUCTURE GWB HEADWALL /SOFFIT 0 10' --0' ;OffU flXWR ERIOR ES 2x2 ACOUSTIC t LUNG 0 10'-0" AFF CO NNG FEATURE: VNra WINI'" FOO TECH UGHTING MONORPL LOIN VOLTAGE 'AERIAL' TRACK (E) GWB SOFFIT 0 8' - AFF 0 • L RECEIVED ITV nF TI AIWA A DEC 2 3 ?003 PERMIT CEN'Ek tO)x 1060 No* US Old Seib WrMigion X105 TMoplue 200.075,151 Fi 21:I.1115.5150 K C L S Connection at Southcenter permit set Divan by Checklist Dale: Revisions: No. DA Ramie SOUTHCENTER 1115 SautlhOenler Mel Tukwila, WA 98188 'cs J MS /i 22 Dsoenber. 2003 14 " ; I O Rellected Ceiling Plan A2.1 NIF %P 111111 1 I /4 " =I' -0` • Hai EAST INTERIOR ELEVATION 0 2' 4 51,911111111 9' -6" (E) SOFFIT A l 8' -6" B.O. (E) PANEL. i j k 7' -6' B.O. SOFFIT ALUM PANEL. SOFFIT AND METAL FRAMING SOLID SURFACE COUNTERTOP 0 2' -6' AFF (E) SECURITY DOOR TO ROAN 6 60'-0" vI V (E) RN. FLOOR 3 /6"O THREADED STEEL ROD •4'- 0'O.C. UII51RUT FRAMING (E) STOREFRONT TO REIM PERFORATED METAL PANEL ON (E) STRUCTURE TO REWJN ---- NORTH INTERIOR ELEVATION xme xi BOOKCASES AND FURNITURE SHAM BE uss mw a'-o' 1/4" =1'- SHEET METAL 8N(NIG NOTE: ALL BOOKCASES AND FURNITURE SHALL BE LESS THAN 8'-O' I/4 •=1' -0• 0' 2' 4' N SOUTH INTERIOR ELEVATION 0' 2' 4' Fili • EXTEND we Mb FRAMING AS REQUIRED (E) SOFFIT TO REIM AXOU1S1IC CEILH; - - - SUSPENDED CO NG 8' - 6' a' - 6' (E) so�rr � ¶(E)sOFHT (E) GLASS STOREFRONT TO REMANII MI PATCH AT SHEET METAL BACKING, 1YP. NOTE: REFER 5/A3.1 FOR FURTHER R ORMMIOM NOTE: ALL BOOKCASES 11 FURN LURE SfNLL t LFSS TWIN e' SOUR SURFACE COUNTERTOP 0 2' -6' AFF 0 0'-0' (E) FNr. FLOOR + (E)AN.FLOOR • 1111111111! WEST INTERIOR ELEVATION I/4•=1' -0' / JUNCTION BOX FOR UGHTED SOMIGE— REFER ELECTRICAL • 0' 2' 4' PATCH AND REPMR 0w8 AS REQUIRED BY REMOVAL OF (E MIRRORS MD NON - STRUCTURAL TRUSS„ TYP. GYM PATCH AT SHEET METAL BACIMG, 1YP. NOTE ALL BOOKCASES AND FURNITURE SHALL BE LESS TH11N 8'--O' 1 1 1 1 1 CITY OF TUKWILA APPRovt0 JAN 2 0 2004 MAW BUILDifi G D1ViSiON RECEIVED err.' T1 11N W l C PERMIT CEN rEF DEC 23 - '003 S0 b SURFACE COUNTERTOP 0 2' -6' PET 1060 Nab 3111 SSW ONO WIr11111aan 11103 Telephone 203 315.9151 Fads* 201.675.$150 K C L S Connection at Southcenter permit set SOUTHCENTER 1115 soulhoenler Mel Tukwila, WA 98188 Dram b Pocket Daly: Scar: Rrririas: Na Dar Rrrrrarls 22 Dsosobrr; 2003 1 1„, Interior Elevations A3.1 • • V 1/4•=I' -O' 0' 2' 4' (E) DOMIN LIGHT PRE-MANUFACTURED STAINLESS STEEL BOOK DROP (E) HOLLOW METAL EXIT DOOR TO REMAIN (E) BUZZER TO REMAIN PARTIAL ELEVATION- BOOK DROP CONC PAVING IN RACE OF (E) LANDSCAPING - REFER FLOOR PLAN • SOUTH STOREFRONT ELEVATION I /4' =1' -0" SOUTH INTERIOR ELEVATION -PLAY AREA in• 0' r %%MA • 0 2' 4' NOM 41 BOOKCASES AND FURNffURE 9 i BE LESS 11*1 I .# 111.1111•• - ten ...∎0w11111.w.... +111.• rr... - • 0 I /4•=I' -0 1/4•=1'-0" WEST STOREFRONT ELEVATION 0' 2' 4' 6i) I f w • 411. .1.•11.0. L. t. / Ch APVVIO JAN 2 0 2t1O4 Bvit� • '1 J ••■..11.141.4 ✓ (E) GINS SOFFIT SOLID SURFACE COUNTERTOP 0 2'-6' AFF NORTH INTERIOR ELEVATION PLAY AREA SWILL a ° � °0` m � e o ` � ° 0' r l>03* RECEIVED :"'17 OF TI 1KWI1 A DEC 2 3 2 003 PERMIT CENTE 1060 Nonh 3INh Steel 8..16. Washi ipon 116103 Telephone 2011.675.9161 F.o1 i 205.515A150 on.Mdnerd led corn K C L S Connection at Southcenter permit set SOUTHCENTER 1115 Southcenler w Tukwila, WA 98186 D avao by: 15 Chocked ,jMs /d3 Nit 22 D.mbsr, 2000 s ��I1_1p, Rations: Na Dab f.n.Is Slorefront/ Interi�' EIeVatIOnS A3.2 A4• • TYPICAL 1 HR. FIRE RATED DEMISING WALL 1 1/2"=1 • 4 61...1 -0 11 41 • 1 TYPICAL SHEET METAL BACKING 3" = 1"-Oe 1 1/2.7.1'-0" 0 3" 6" ..IMMI■ 1111110■10 •■■■ 110 MEWS TOP NI BOTTOM AT DAM STUD 5/8* FTRE-RATED GYM PATCH AS REQUIRED 1 1 SECTION @ BACK WALL SOFFIT 0,14, 11 4° Immili LCr 10 (E) MEM FINING N1D ACOUSTIC 1W INSIAATTON TO II" Wee CONTINUOUS 22 St MEET METAL BACKING / - FURNITURE/ COUNTERTOP EMMONS AS NTED, REFER • DEFLECTION JOINT 3• = l'-0" ) 0 3• 6" 1 1111 61 .111.1 %■un 1 0 BRACE • 4'•0" O.C. W/ 35E162-54 METAL FLASHING- (3) 18 TOP frie BOTTOM HEADER PER STRUCTURN. ACOUSTICAL =NG TLE & SUSPENSOR SYSTEM I 11 I BIM IIIIIII 9" h A.C.T. AT GWB SOFFIT 0 a SECTION @ SCREEN 1 11•xr-1• 0 6' II-0" A '1: • a.". 0 3" 6" 358T150•33 TRACK TOP N BOTTOM W/ 16 • 12* oc. • TOP IMITOM 5/8' GW8 HEADWALL (2) 800S182-54 SCES 358S150-54 TRACK TOP N4D BOTTOM W/ 18 SCREWS • 6' O.C. DIM PT 2 1/2 RESLIENT MALL BASE AN. SURFACE PER FLOORING PLAN (E) SLAB NTS 1 ACOUSTICAL ILE Wt4 IEE TYPICAL ACT SUSPENDED CEILING 1 SECTION 0 BOOWDROP 1 1/2":1'-0" 0 6" r-c• • TOP CUP W1 MECH. FASTENER TO STRUT 100 LB CAPACITY WNW INCHON TO STRUCTURE COMPRESSION STRUT CONNECT TO STRUCTURE ABM (200 LB. CAPACITY F.S. Kr-o. O.C. TYP 12 GA LATER&4. BRACING WHIN 2" OF CROSS TEE 111/ 4 TIGHT TURNS IN 1 1/2% BOTH ENDS OF MIL TYP CROSS TEE 12 GA VERT IIVIGER WIRE CONNECT TO 14*1 TEE (E) EIRKX VENEER (E) 6 klETAL STUDS (E) 3 1/2" METAL STUDS (E) STEEL FRAME BEYOND (E) 1x CASING PER MFR INSIALLOON INSIRIA:NONS SS BOOKDROP INSTALLED PER MFR STD DTLS 0, CONT GLAZING TAPE 0 INTEGRATED FLANGE - ALL FOUR SIDES FINISH SURFACE PER FLOORING PIM (E) CONC SLAB (E) COW MD EXPANSION JOINT CONCRETE PAVING TO MATCH (E) a 4 4 1) • 44 1 ■ 1 . cy . r .,:RECE WED WWII A CEC 2 3 2 P ERmor cENT 1000 No 30 WM Swab Waiickm 91103 Tek•Aor• 201175:151 2011171919) avauktrichbdazo KC LS Connection at Southcenter permit set SOUTHCENTER 1115 Southcenier Mall Tukwila, WA 96188 Draw by. ks/ Owlet • J' wis /60,5 Oa* 22 Oscerriar, 2003 Scab: Roams: No. Dab Remota Wall Sections/ Details A4.1 MED GRILLES, REGISTERS & DIFFUSERS MARK CFM STATIC PRESSURE SIZE BASIS FOR DESIGN PRICE RCD PRICE 80 REMARKS 1 FRAME 24" X 24" 24" X 10" DUCT 10" ROUND SEE PLAN SD - 1 RG-1 — 330 330 1000 0.06 0.05 NOTE: 1. PROVIDE SPECIAL FACTORY FABRICATED LAY –IN CEIUNG MODULE. • ABBREVIATIONS ABBR ABV AC ACU AFF APPROX ARCH ASHRAE BDD BFF BOO BTUH CD CFM CO COND CONT CW DB Db'1l. DEG DIA DIM DN DWG EA ELEV, EL EAT EG ESP EWT EXIST EXH FCO FD FLA FLR FT G GA GAL GALV GPH GPM GRD HP HVAC HW HWC HWR HWS ID IN KW LAT LWT MAX MBH MCA MIN NIC NTS OA OAT OC OBD OSA POC PRV PSI RA RD REF RG RPM RPBP SA SM SMACNA .7O SP SPD SPEC SWT TDH TOD TPD TSP TYP v 0 VTR w WB WCO VYG VA-1 ABBREVIATIONS ABOVE AIR CONDITIONING AIR CONDITIONING UNIT ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING BACKDRAF T DAMPER BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEIUNG DIFFUSER CUBIC FEET PER MINUTE CLEAN OUT CONDENSATE CONTINUATION COLD WATER DRY BULB TEMPERATURE DECIBELS – A WEIGHTED DEGREE DIAMETER DIMENSION DOWN DRAWING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING EXHAUST FAHRENHEIT FLOOR CLEANOUT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FLOOR FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GALLONS PER MINUTE GRILLES, REGISTERS, AND DIFFUSERS HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATING HOT WATER RETURN HOT WATER SUPPLY INDIRECT DRAIN, INSIDE DIAMETER INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM NOT IN CONTRACT NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER OUTSIDE AIR POINT OF CONNECTION PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH RETURN AIR ROOF DRAIN REFERENCE RETURN GRILLE REVOLUTIONS PER MINUTE REDUCED PRESSURE BACKFLOW PREVENTER SUPPLY AIR SHEET METAL SHEET METAL AND AIR CONDITIONING CONTRACTOR'S NATIONAL ASSOCIATION SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS SWITCH TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WALL CLEAN OUT WATER GAUGE WALL HYDRANT NOTE: DRAWINGS MAY NOT CONTAIN AU. ABBREVIATIONS USTED LEGEND SYMBOL XX OR L -- +r•III•w NMI MEP woo - =1.111•1•1.111111•1 INIMIII■111■ IMO iM■HiN.I. NO 0111 ■MP T � F/so ►.t 0 FLEX DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SHOWN UGHT UNE, EXISTING HEAVY UNE, NEW WORK EQUIPMENT ITEM XX NG NATURAL GAS W SOIL OR WASTE V VENT CW DOMESTIC COLD WATER HW DOMESTIC HOT WATER HWC HOT WATER CIRCULATING PIPE SIZE REDUCTION ELBOW UP ELBOW DOWN TEE OUTLET UP TEE OUTLET DOWN VTR VENT THROUGH ROOF DIRECTION OF FLOW ROUND DUCT EXHAUST OR RETURN INLET SUPPLY OUTLET BDD BACK DRAFT DAMPER MOD MOTOR OPERATED DAMPER VD VOLUME DAMPER FIRE AND SMOKE DAMPER EXH OR RET EXHAUST OR RETURN AIR DUCT SUP SUPPLY MR DUCT FLEXIBLE CONNECTION DOUBLE UNE FLEX FLEXIBLE CONNECTION SINGLE UNE SYMBOL +11D+ + 1 R of/4010Z V. ttd se" .4■El .1 X/Y ABM DESCRIPTION OFFSET D01Md IN FLOW DIRECTION OFFSET UP IN FLOW DIRECTION TRANSITION ROUND TO RECTANGULAR TV TURNING VANES IN SQUARE DUCT DUCT VA TH 1" THICK ACOUSTICAL UNING DUCT WITHOUT SOUNOLINING SINGLEUNE DUCT WITH 1" THICK ACOUSTICAL UNING DEMOUTION WORK SUPPLY GRILLE OR DIFFUSER INDICATE AC71VE ELEMENTS (4 WAY IF NOT SHOWN) RETURN OR EXHAUST GRILLE DIFFUSER OR GRILLE CALL OUT CFM X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION THERMOSTAT SWATCH DIFFUSER NECK (SQUARE OR ROUND) OVAL CONNECTION MAY BE USED FOR AREAS WHERE CLG SPACE IS LIMITED PLAN SMACNA APPROVED CLAMP FLEX DUCT MOUNTING FLANGE DIA EQUALS FLEX DIA DIFFUSER NECK SIZE ELEVATION DRAWING INDEX DUCT ATTENTUATOR SCHEDULE MARK 51-1 LENGTH 36 INCHES STATIC PRESSURE .05 _ DUCT CONNECTION SEE DWG OCTAVE BAND INSERTION LOSS BASIS FOR 63 1 125 1 250 1 500 1000 2000 4000 7 1 8 1 17 1 20 1 18 1 13 1 11 8000 1 1 DESIGN IAC 3LFM NOTE: DYNAMIC INSERTION LOSS BASED ON FACE VELOCITY OF –1000 FPM 1 FLEX IWO 1 CEILING M0.1 LEGEND, ABBREVIATIONS Os SCHEDULES M1.0 MECHANICAL DEMOUTION PLAN M1.1 MECHANICAL PLAN GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING PLANS, DIAGRAMS, DETAILS. ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND WORKABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS USTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA BASED ON AND IN COMPLIANCE WITH DIVISION 1 OF THE SPECIFICATION, AND VA TH THE WRITTEN APPROVAL OF THE ENGINEER. COORDINATE THE INSTALLATION WI TH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK SHALL BE NET FREE DIMENSION WITH SOUND UNING INSTALLED. SOUND UNING SHALL BE 1" THICK UNLESS OTHERWISE NOTED. 5. PIPING OR DUCTWORK PENETRATIONS THROUGH WALLS. PARTITIONS, CEIUNGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. PIPING, DUCTWIORK, OR STRUCTURAL COLUMN PENETRATION THROUGH PLENUMS, DUCTS OR RETURN SHAFTS SHALL BE SEALED AIRTIGHT. PIPING PENETRATIONS THROUGH SLAB SHALL BE SLEEVED AND SEALED WATERTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, MOTOR STARTERS AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ALL REQUIRED EQUIPMENT GUARDS AND STRUCTURAL SUPPORT AS RECOMMENDED BY EQUIPMENT MANUFACTURERS TO SUPPORT EQUIPMENT AND TO ASSURE SYSTEM PERFORMANCE AND SAFE OPERATION. COORDINATE PRIOR TO INSTAULATION. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT. ACCESS VALVES AND DAMPER OPERATORS. COORDINATE FIRE RATING WITH THE ARCHITECTURAL DOCUMENTS. 8. COORDINATE LOCATION OF ALL THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE ARCHITECT. LOCATIONS AS SHOWN ON THE DRAVANGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -6" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. 10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. PROVIDE MINIMUM OUTSIDE AIR PER WASHINGTON ADMINISTRATIVE CODE REQUIREMENTS. 13. SHUT OFF FOR SMOKE CONTROL PROVIDE SMOKE DETECTORS FOR AUTOMATIC FAN SHUT DOWN IN AIR HANDUNG UNITS IN ACCORDANCE WITH UMC SECTION 608. 2 X DUCT DIAMETERS (o)—ol 1" SOUND UNING C JAN A5 BUILDIN or V i SCALE: NONE NOTE: SIMILAR CONNECTION FOR RETURN AND EXHAUST EXCEPT NEGATIVE FLEX CONNECTION W/ DUCT DIFFUSER CONNECTION DETAIL • • CEILING RETURN W /ACOUSTICAL DETAIL (TYPICAL) SCALE: NONE 1 1 ` � r s t . i s CITY GF TUK ILA API'RUvtt) • 2 0 2004 Iii✓ i tU G DIVISION , 1)0 RECEIVED "TTY C)r Tl IKWII A DEC 2 32003 PERMIT CENTER d 1 --"11261-21211a111421 Lame nAm - SEPARATE PERMIT AND APPROVAL REQIi! RE D 1 1 1050 North 38It Street Seattle Washington 98103 Telephone 206.675.9151 Fusin* 206.675.9150 www.sedularchitectaarn THE OREENBUSCH GROUP. INC. ))) MilkailtuMFE Imam 1110/104 SOUTHCENTER 1115 Soutltoerder Mel Tukwila, WA 98188 K C L S Connection at Southcenter Permit Drawings SOUTHCENTER 1115 Soutlioenler Mall Seattle, WA 98188 Drawn by: Checked: Dale: Scale. Revisions: No. Dale RR mG 22 December, 2003 yr = 1'-0' Remarks NOT FOR CONSTRUCTION ABBREVIATIONS, LEGEND, INDEX II GENERAL NOTES M 0.1 • OPEN TO SPACE EXISTING PACKAGED ROOFTOP TRANE UNIT TO REMAIN • i EXISTING EXHAUST GRILLE & EXHAUST FAN TO REMAIN 1 ( 20 /io (TYPICAL) FLAG NOTES: REMOVE EXISTING WATER CLOSET. REMOVE WASTE AND DOMESTIC WATER PIPING BACK BEHIND WALL AND CAP. REMOVE EXISTING LAVITORY. REMOVE WASTE AND DOMESTIC WATER PIPING BACK BEHIND WALL AND CAP. REMOVE EXISTING SINK. REMOVE WASTE AND DOMESTIC WATER PIPING BACK BEHIND WALL AND CAP. REMOVE EXISTING HOT WATER HEATER. REMOVE HOT /COLD DOMESTIC WATER PIPING BACK BEHIND WALL AND CAP. • ED— MECHANICAL DEMOLITION PLAN SCALE: ,fir in r • REMOVE EXISTING GRILLE AND FAN n it IL _ `qll■ r �I . ' T I L b ri o. J 1 1 FAN V r Gf CAP • J r 1 L L 6" F 1 1 8 "o 200 1 T - T EXISTIN a HOT WATER HEATER LOCATED ABOVE TO REM tN EXISTIN e LAVATORY TO REMAIN -- EXISTIN a WATER CLOSET TO REM IN SEPARATE PERMIT AND 1:;01) iip iip i:.Pr..1,1)R,OIRVLADL • 4 � • CITY OF TUKC,`riLA APf ROvd) JAN 2 0 2004 AS trig I Li) BUILDING DIVISION RECEIVED f ITf ( TI I1(W1I a D E t 2 3 '()O PERMIT :.ENTEh 1060 North 36th Strut S.alt1. Wahinplon 96103 Telethon. 206.675.9151 Facsimile 206.675.9150 west ohkoorc iilocio oom THE GRBENBUSCH GROUP. INC. ) )) 110,1111131 SWUM SOUTHCENTER 1115 Southcenter MaM Tukwila, WA 98188 K C L S Connection at Southcenter Permit Drawings SOUTHCENTER 1115 Southcenter Mal Seattle, WA 98188 Drawn by: RR Checked: DWG p er: 22 December. 2003 114" = 1'.O Sale: Revisions: No. Dale Remarks NOT FOR CONSTRUCTION MECHANICAL DEMOLITION PLAN M1.O • PLUMBING CONNE TION SCHEDULE FIXTURE MARK SYMBOL SERVICE CONNECTION WASTE VENT CW HW SINK S-1 y 2 1/2 1/2 EXTEND AND CONNECT PIPING TO SINK. FURNISH COMPLETE, FUNCTIONAL SYSTEM. 20/18 HOLD TIGHT TO STRUCTURE 1 I I 14/42 AHU ON ROOF 20/18 HOLD TIGHT TO STRUCTURE fI 1 8 " O E LAG NOTES: PROVIDE ARE SPRINKLER COVERAGE FROM EXISTING FIRE SPRINKLER SERVICE. RELOCATE SPRINKLER HEAD AS NECESSARY. SEE SPECIFICATION SECTION 15300. REPLACE ALL TORN INSULATION. INSULATE ALL SUPPLY DUCT WORK PER SPECIFICATION 15200, TYPICAL. ADJUST SETTINGS ON WATER HEATER TO CURRENT CODE TEMPERATURES. REPLACE LAVATORYS P— TRAP AND CLEAN OUT LAVATORYS WASTE UNE. COVER RETURN AIR OPENING WITH MESH SCREEN. HW & CW POC NEAR EXISTING HOT WATER HEATER. SHEET NOTES: 1. FLEX DUCTWORK SHALL BE LESS THAN 5 FEET IN TOTAL LENGTH. 2. BALANCE NEW AND EXISTING DIFFUSERS TO VALUES SHOWN. • T 375 (TYP OF 6) • • c� uNC RETURN WITH ACOUSTIC DETAIL, SEE MECHANICAL PLAN SNIMIIIIM 1000 OF 2) 10 "0 (TYP OF 6) 10 "0 1 330 (TYP OF 6) 10 "0 0"0 1 Si" HW & le c* HOLD TIGHT TO STRUCTURE 1 1 1 1 750 WATT. 115 V INSTAHOT CAP 1 10"0 • 10 "i IJ 10 " L 1 10 "0 10 "o t 10 "0 4— Kg-q SAW CUT EXISTING POC POC FLOOR " M C1v' 0 0 - (040) ,A.Ist 2 7.04k 11,6 tst0i0 1301_ONG 01\:\101.4 • • HECE vE ON OF T !KW' 4 DEC 23 ?003 PERMIT UENTE SE PERMIT AND 41)5 AFPA REQUIR I . . . .. . . . . . .. . .. MVO 1050 North 361h SMwt Sadie Washington 96103 teMphione 206.675.9151 Facsimile 204.675.9150 www.shksardrlede.aom Ill K C L S Connection at Southcenter Permit Drawings THE OREENBUSCH GROUP, INC. intlizugaiM [mots 9111/1104 1 SOUTHCENTER 1115 Southcenter Mal Tukwila, WA 98188 SOUTHCENTER 1115 SoutlioerNer Mall Seedle, WA 98188 Drawn by Checked: ,NVG Dow 22 December, 2003 Scale: 1!4 = 1'-0' Revisions: No. Dale Remarks NOT FOR CONSTRUCTION MECHANICAL PLAN M1.1 • 1 Pro$Ot Ws Arlen OS MEM lasted •sins i M— ' Ode 12/19/2003 , DEMOUTION PLAN Orin—an WO Fer MiMNp Oseerb ant Uss E3.0 er rWA *Om* Nem= OBE Olsom wl One AOpNoont Address: MM VW IIur Otis III *ISM 111A nes Amami* Phone: w1/ u" 119 DRAWING INDEX E0.0 SYMBOLS AND ABBREVIATIONS E1.0 DEMOUTION PLAN E2.0 POWER & COMMUNICATIONS PLAN E3.0 uGHTING PLAN , E4.0 _RISER DIAGRAM, PANEL SCHEDULES & SWITCHBOARD LAYOUT Leoetisn (floor /room no.) Oooupaney Description Moved T Watts per 112 .s Arso in ft2 Allowed x Area limy tww' Ow os NSW _ 1.1 1121.0 1001.1 Way (W.r• oa121O 40 00 is 1001.0 OWLS ve war Tea Taut A Lr Trask DP el Tessa 47 06 1174.0 Aso owe Mir flu ! Soo 000.0 v wee 4111 st roam oar spa= 16 71 1110.0 1.S Padre In twsig Ileac 11 4 24 00 204.0 240.0 ** From Table 15-1 (aver) - document ale emotions on fare LTG -LPA Ted $102.0 1047.3 Location - (low/room no. ) Fixture Description Number of Fixtures w,/ Fixture watt Proposed IMM 1., .Ms ewe awry 0 71 440.0 I: Ilesessed ws.....r w s• t a Oa fa 20 1100.0 ve war Tea Taut A Lr Trask DP el Tessa 47 06 1174.0 Aso owe Mir flu ! Soo 000.0 v wee 4111 st roam oar spa= 16 71 1110.0 1.S Padre In twsig Ileac 11 4 24 00 204.0 240.0 IA Wow Paint at ark Wm. LW Cleue i i i i r a i m 3 7! 110.0 u+ ..►Ole WNW is idea `s..rp• 24 0 0.0 Total Proposed watt may not ceased Total Nosed watts for ',Airier Told Popeo ed WN M 02110.0 • • 1 ■■1/11.- -1 • • NEN cso o 0 O 0 DUPLEX RECEPTACLE 120V ' DOUBLE DUPLEX RECEPTACLE 120V DUPLEX RECEPTACLE – GROUND FAULT CIRCUIT INTERRUPTER TYPE DUPLEX RECEPTACLE – CEIUNG MOUNTED RECEPTACLE – FLOOR MOUNTED SAFETY TYPE RECEPTACLE DUPLEX RECEPTACLE – DEDICATED CIRCUIT PANEL -- 208 VOLT SYSTEM. +8' TO TOP U.N.O. EQUIPMENT CONNECTION FUSED DISCONNECT NON –FUSED DISCONNECT di) (il VD II Sm rag v LIGHTNC SYAAIOLS FLUORESCENT FIXTURE. TYPE AS INDICATED ON PLAN FLUORESCENT STRIP FIXTURE. DRAM TO SCALE TRACK UGHTS. CEILING MOUNTED FIXTURE CEILING MOUNTED FIXTURE PENDANT MOUNTED FIXTURE CIRCUITED VIA EMERGENCY BATTERY BACKUP SYSTEM EXIT SIGN MATH ARROWS AS INDICATED CUSTOM FIXTURE. SEE FIXTURE SCHEDULE SINGLE POLE SWITCH DIMMER SWITCH FURNITURE MOUNTED UGHIING POWER SYMBOLS ELECTRICAL SPECI FI QATI ON S: SECTION 16010 – GENERAL PROVISIONS Provide complete and operational electrical systems as specified and /or shown on the drawings. A. Codes: Conform to the latest applicable edition of the National Electrical Code, State of Washington Electrical Code, and Vocal ordinances. B. Permits and Fees: Obtain and pay for all required licenses, permits and inspections. C. Coordination: Coordinate electrical work with other trades. Obtain drawings for all disciplines. Contractor is responsible for reviewing all documents as they relate to the electrical documents and shdl notify the architect immediately of any conflicts noted. D. Testing & Warranty: Test the electrical systems for proper operation and provide one full year warranty after completion. E. Record Drawings: One (1) full print set at the job site, kept continually updated. Submit to Architect at completion of project. SECTION 16100 – BASIC MATERIALS AND METHODS General requirements for materials and installation methods, pointing, dean –up. and workmanship. A. Materials: Provide new equipment unless noted otherwise. All equipment shall be listed by Underwriters Laboratories or other approved testing organization and shall be so labeled. B. Substitutions: Where substitutions are allowed they shall be reviewed by the Architect prior to acceptance. C. Submittals: After award of contract submit three common bound brochures (one copy returned to Contractor) containing catalog cuts for the following items: Wiring Devices Cable Tray Disconnects and Fused Switches Lighting Fixtures Panel and Circuit Breakers D. Painting: Repaint any electrical items scratched or marred in shipment or installation. E. Clean Up: Continually remove debris resulting from the electricd installation work. Clean all electrical equipment at completion of project. F. Equipment Connections: Provide all electrical connections necessary to serve new or relocated equipment and provide required control connections to all equipment so that the equipment is fully operational upon completion of the project. Prior to rough –in, obtain copy of submittals and shop drawings for all equipment requiring wiring electrical connections being furnished under other divisions. Provide wiring per the ring diagrams and requirements indicated. SECTION 16110 – RACEWAYS A. Interior Raceways: Electrical metallic tubing (EMT) with steel compression or set screw fittings. Indentor, drive –on and pressure cost on die cast type set screw fittings are not acceptable. Conceal dl raceways in walls or ceding spaces where ever possible. Where specifically noted surface metd raceways may be used. B. Flexible Raceways. Galvanized flexible steel conduit for dry locations. Flexible metallic tubing permitted for light fixture pigtails only. C. Exterior Raceways: Rigid galvanized steel or PVC where permitted by code and for underground runs or concrete encasement D. Raceway Penetrations: Penetrations through fire rated construction shah be sealed using 3M Fire Barrier Caulk, Nelson Electric nemesia! or T & B Fiomesafe or use other method approved by the Architect. F. G. MC Cable and /or Romex not occeptable except where specificrdly called for. For roof mounted equipment, raceways) shall penetrate the roof within the roof curb. shdl AN wiring be run in conduit raceway. SECTION 16120 – CONDUCTORS AND TERMINATIONS A. Copper, insulated for 800V. Type THI MN/T1 *IN or *VW, *12 AWG minimum. B. Spikes: Solderlss type only. Preinsuloted "twist –on" type (limited to size /10 and smaller). Bolt or compression set type with application of preformed insulated cover, heat shrinkable tubing or plastic insulated tape acceptable for all sizes. C. Terminations: Compression set, bolted or screw terminal. • 4 a A. B. C. D. - - o SYMBOLS & ABBREVIATIONS Color: Ivory. SIGNAL it GOMMIRICA710N SYMBOLS COMMUNICATION OUTLET (# INDICATES QUANTITY): 'P' INDICATES PAY PHONE 'C1/' INDICATES CREDIT VERIFICATION PHONE INDICATES WALL PHONE ▪ DATA OUTLET (1 INDICATES QUANTITY) • SYSTEMS OUTLET: "SCO" INDICATES SELF CHECKOUT "LCS" INDICATES UBRARY CATALOGUE STATION Q SPEAKER PUSH BUTTON CIRCUITING SYMBOLS NEW WIRING. HASH MARKS INDICATE NUMBER OF #12 AWMG WIRE UNLESS OTHERWISE NOTED, OTHERWISE. NO HASH MARKS INDICATES TWO MIRES PLUS GROUND UNLESS NOTED OTHERWISE. LONG HASH MARKS DENOTES NEUTRAL. INDICATES GROUND WIRE. NEW WIRING RUN IN OR BELOW SLAB OR BELOW GRADE. RACEWAY STUB–OUT WITH BUSHING HOME RUN TO PANEL OR LOCATION NOTED RACEWAY UP RACEWAY DOWN CIRCUIT CONTINUATION Q JUNCTION BOX EXISTING RACEWAY OR WIRING (IF HASH MARKS ARE SHOWN PULL NEW CONDUCTORS) CABLE TRAY SECTION 16130 – OUTLET AND PULL BOXES • A. Interior Wiring: Pressed steel, zinc coated with plaster ring where applicable. Mount outlet boxes for receptacles and other devices at 18 ", or match existing outlet heights. B. Surface Metal Raceway: Boxes of some manufacturer as raceway. Boxes shall accommodate standard device plates. C. Exterior Wiring: Cast or malleable iron or shall be cast of corrosion resistant alloy, with conduit hubs compatible with raceway to which it is connected. All boxes shall be Labeled for damp or wet locations as applicable. SECTION 16139 – CABLE TRAYS A. Provide complete cable tray system with accessories, fittings and all mounting hardware as required B. Aluminum construction – ladder type, ventilated bottom. 9 "W X 6 "D with 9" rung spacing. C. Manufacturer B –Line, Husky, PW, & Mono– Systems D. Install level and parallel to buMding structure. SECTION 16140 – MIRING DEVICES B. Switches: Specification Grade, Federd Specification W –S 896, back and side wired, rated 120 volts, 20 amp. Provide single pole, double pole. keyed, 3– way, pilot Tight. locking type or as required. Pass & Seymour 20AC1 –i, Bryant 4901 -1. Hubbell 1221 -1, Leviton 1221 -1, Eagle 2221V, An-ow Hort 1991 -1, or General Electric GE 5951 -2G. C. lfioat Federal iflc tion –5 , p e x N 5-1 con ra tii on amp, 0 unless own o erwise. an wired. ass & Seymour 5252 -1, Hubbell 5252 -1, Leviton 5252 -1, Bryant 5252 -1, Eagle 5252V, Arrow Hort 52521, or General Electric GEN 5252 -2. (Provide 20 amp devices on dedicated 20 amp circuits.) Install receptacles with ground pin up. D. Ground Fault Circuit Interrupter (GFCI) Receptacle: Specification Grade, NEMA 5-15R configuration, duplex receptacle with 4-6 milliamps leakage current trip Level. Ivory color. Arrow Hart GF- 5242 –I, General Electric GF 5342 -2, Hubbell GF- 5252 –I, Leviton 6599 -1, or Pass & Seymour 1591 -51. E. interior Device Plates: Rigid plastic, smooth, ivory color. Flexible nylon device plates not occeptible. F. Incandescent Dimmers: Specification grade, non – preset, slider type dimmer. Single pole with LED off indicator. 1000W rated. Leviton IllumaTech or equal. G. Fluorescent Dimmer Coordinate and provide fluorescent slider type dimmer in accordance with and compatible with fixture supplied dimming ballast. Contractor is responsible for coordinating ballast and dimmer compotiblity with fixture manufacturer. H. Surface Raceway: a. Steel construction, complete with all fittings, accessories and mounting hardware as required. Color 111 Ivory b. Grounding receptacles, 20A rated, 18" o.c. Max 4 per circuit. c. Manufacturer: riirernold 2100 Series or equal. SECTION 16170 – DISCONNECTS AND FUSED SNITCHES Unfused: Heavy duty type, horsepower rated with interlocking cower. NEMA 1 typicd, except whore shown outside or identified as "MVP" shall be NEMA 3R. Provided with fuse space and dips to accept Class R fuses where indicated to be fused. Provide permanent label indicating Wood served, voltoge, phase, horsepower, fuse size and type. SECTION 16450 – GROUNDING Provide ground wires to receptacles and within all circuits run outside the building. Metallic raceways shall utilize double Iocknuts and other fittings listed as providing grounding continuity. SECTION 16471 – PANELBOARDS Deod front type. UL 67, NEMA P81.1 compliant. 100% Neutral and Ground Bus. Manufacturer: Square D, Cutler Hammer, Siemens Compatible breakers: Boit an, minimum 10,000 MC rated. 20A minimum. Contractor shall verify and provide nwinufocturer's equipment with proper MC ratings to match or exceed existing protect conditions. c> r •__ - - - t_ 1 FLAG NOTE REVISION SYMBOL EXISTING EQUIPMENT OR DEVICE EM EN ROVE EXISTING ELECTRICAL EQUIPMT EQUIPMENT IDENTIFIER ABIREVIAliONS AC INDICATES ABOVE COUNTER MOUNTING AT +4" ABOVE BACKSPLASH OR +d" %M OUT COUNTERS OUT BAO(SPI,ASH AFT ABOVE FINISHED FLOOR A. AMP AMPERE BOF BOTTOM OF FIXTURE CB CIRCUIT BREAKER CKT CIRCUIT DED DEDICATED (E) EXISTING G. GND GROUND GF1. GFCI GROUND FAULT CIRCUIT INTERRUPTER HT HEIGHT J–BOX JUNCTION BOX SECTION 16742 – SURGE PROTECTION A. B. C. D. r MISCILLAIMUS Section 16550 – CENTRAL BATTERY EMERGENCY UGHTING A. UL 1449, UL 924, UL 1778 listed. N P PNL RO RECEPT REFRIG NEUTRAL POLE PANEL RACEWAY ONLY RECEPTACLE REFRIGERATOR TELEPHONE TYPICAL VOLT ME OR WATT PHASE WITHOUT OUT ANSI/IEEE C62.41, UL1449 listed. LN. NG, LL protection with self diagnostics. 120/208V, 30, 4w, G. Stand done panel protection, Min.: 80kA max surge current. Manufacturer. Leviton, 42000 Series. APC PM2 Series. SECTION 16500 -- UGH1ING Provide a new lighting system complete and fully operational and in conformance with code and U.L. listing requirements. A. Catalog Numbers: Model and series numbers indicate design intent in terms of fixture quality and general requirements. The actual fixtures submitted shill correspond with the number of lamps, wattage, ceiling type and any other specific performance and instillation requirements specified or shown on drawings. Verify actual requirements prior to ordering fixtures. B. Lamps; Fluorescent type Bi –pin, T -8 rapid start, 32 watt, 35001( color temperature unless otherwise noted. Compoct 11T and DTT, 35001( color temperature unless otherwise noted. C. Magnetic Fluorescent Ballasts: Shall be HPF (greater than 907(). UL and CBM listed, and certified by ETL Shall be Class P, high power factor type; "A" sound rating. Approved manufacturers are Advance, Magnetek, Valmont or Robertson or as specifically noted in the fixture schedule. D. Electronic Fluorescent Ballasts: Shall meet the following regulatory requirements: EMI and RFl limits set by the FCC (CFR47, part 18 and FCC Part 18,15D ANSI Standards C.62.41 transients and IEEE publication 587. category A (transients) Minimum efficiency standards of Public Low No. 100 -357 Starting sequence consistent with ANSI standard C82.1 -1993 • Reduced light output ballasts (ballast factors below 87%) are not acceptable except as noted otherwise in the fight fixture schedule. • Total harmonic distortion shall be less than 2071 of the input current. Current crest factor shall be less than 1.7. Operating frequency shall be between 20 and 60 kHz with no visible flicker. • Rapid Start ballasts shill be wired is series (or in parallel if manufactured accordingly) and Instant Start bdlasts shall be wired in parallel. • Acceptable manufacturers: EBT, Advance, Magnetek, Valmont, Osrom. E. Fluorescent Dimming Ballasts: to be supplied by and provided in accordance with fixture manufacturer published recommendations and/or specifications. Fixture manufacturer shall guarantee compatblity of supplied ballast with fixture. See 16140 for dimming control requirements. B. Maintenance free, sealed lead battery 8 year life min. 90 min. runtime. Hot swappable. C. Solid state charging system, self diagnostic, with user test switch. m D. Provide with adequate interface odules) as required to puss controlled circuits and with Monufocturer's mounting /shelving hardware. E. Manufacturer: Powerd RG1000 or equal. SECTION 16999 – PROTECT CLOSEOUT Perform test to confirm proper operation of all devices and systems InstaNed, address and correct all find punch list items and deliver "as–built" mark –up drawings to Architect Lighting Summary Prol_ot Desoription Cla ❑New &Aldine n ®*motion 091dg. >9,000 sm 00o .ft. (auto shutoff reo ®Pleno looludsd Indicate controls (SEC Section 1513) including commissioning requirements on pions. Alteration Emotions ( a app1e► box) DN► ohongen e• being mode to d+. lighting E1CSOX of fixtures n. histdlsd M011ltrq watbsge le not increased. and Table 15 use is net charged Maximo Allowed Lu s Luting Watts anterior) Proposed lighting Wattage Ont.) 2 0 z KEY PLAN =ALE sac N o d . on Pnrl+assd Wiling 1. use menelocturs's MAW reaxdmum Input wattage. For bard - wired Womb only, the default fable :n is NaE7C Teduded Nelerunee Mu.Npl nay also be wed. 2. Muds end IiMIMs onoesdlne 5.0 watts per fetus. 3. List al fixtures. Far arrrwipt ylrllrq, net arroapeen en applicable fbtwss. CM ppNK3'tO 3A14 2 020 it 8 ILC1t45 V ISiON N 0 LTG -SUM 11 \,,,,, REQUIRED .EPA RA T F_ PERMIT AND Af PRDVAL REQUIRED MAIN ELECTRICAL ROOM NEW UBRARY SPACE PECENE "rr r.r 71 IKWH A DEC .' 3 2003 PERM CENTER MITSET 1Y/7L03 1060 Nor•3SM+ See S one Washington 611103 Telephone 2011.1175.11151 Facsimile 2011.11759160 www SOUTHCENTER 1115 Southcenter Mel Tukwila, WA 98188 K C L S Connection at Southcenter Permit Drawings SOUTHCENTER 1115 Southcenter Mall Seattle, WA 98188 Drown by: LES Chsclred: Delo: Scala: Roviiriarit_ No. Dale W 1-� a ,,,,•••• 5 at o C1 + fi t Immo li? a F. Remarks W MIND V ar 1 EXPIRES 1 - I R(r9PP NO ripwU BBB NO SCA F SYMBOLS6 ABBREVIATIONS EO.O' . TO .. .+.R . .. r 1. 1 + + i 7 .1 ' i \— ; C UNIT ON ROOF ABOVE 1 0 f- 4 �r -t l • • STORE SHELVING FLOURESCENT STRIP UGHTING (TYP) --'� ir.• I. LOW — VOLTAGE TRACK LIGHTING (TYPICAL) + + • tA GENERAL NOTE8: 1. UNLESS NOTED O7HERIMSE. INDICATED DEVICES, EQUIPMENT AND FIXTURES ARE TO BE REMOVED. ALL ASSOdAiED RACEWAY /CONDUCTOR IS TO BE REMOVED BACK TO SOURCE. INDICATED LAYOUT IS BASED ON FIELD VISIT AND PREVIOUS TENANT DRAWINGS ONLY. "THIS DRAWMIG IS INTENDED ONLY TO SHOW MAGNITUDE OF GENERAL DEMOLITION REQUIREMENTS. CONTRACTOR SHALL INCLUDE IN THIS BASE BID AND BE RESPONSIBLE FOR FULL DEIAOUTION AS REQUIRED TO SATISFY INTENDED DESIGN REQUIREMENTS. • 'A 1- 2. CONTRACTORS OPTION: WHERE PRACTICAL, CONTRACTOR MAY REUSE EXISTING RACEWAYS FOR NEW WORK IF DESIRED. WHERE RE— USED, RACEWAYS SHALL. BE KEPT PARALLEL TO BUILDING LINES AND ROUTED WITH NEW WORK WHERE POSSIBLE. ABANDONED RACEWAY NOT ALLOWED. FLAG NOTES: 13>m. TENANT PANEL AND ASSOCIATED FEEDER/RACEWAY TO BE REMOVED BACK TO SOURCE (MAIN ELECTRICAL ROOM). RACEWAY ONLY MAY BE STUBBED INTO GENERAL MALL ASE CDIJNG SPACE. DO NOT LEAVE IN TENANT COUNG SPACE �j TENANT PANEL TO BE REMOVED. CONTRACTOR TO MAINTAIN FEEDER/RACEWAY IN COUNG SPACE FOR EXTENSION TO NEW TENANT PANEL AC UNIT FEEDER TO BE RECONNECTED TO NEW TENANT PANEL. MAINTAIN AS REQUIRED. E3::;:l MAINTAIN STORE SIGNAGE CIRCUIT AND CONTROLS FOR CONNECTION TO NEW SIGNAGE I::::' TENANT TELEPHONE SERVICE TO BE EXTENDED OR REPLACED PER MALL STANDARDS. MAINTAIN EXISTING RACEWAY AS REQUIRED FOR EXTENSION TO NEW LOCATION. SEE E2.0. 13> TENANT TELEPHONE SERVICE TO BE REMOVED. REMOVE ALL ASSOCIATED CONDUCTOR/RACEWAY BACK TO SOURCE (MAIN ELECTRICAL ROOM). Et> EXISTING HVAC CONTROLS AND FIRE SHUTDOWN/RESET TO BE MAINTAINED AND EXTENDED TO NEW LOCATION. SEE SHEET E20. Ce— 9— I --e TO PAN , — POWER dt (; TELE/DATA TO CASH WRAP POLE • LOW —BAY PENDANT FlXTURE Cam) { _ -e -- --.- - ITT SCALE: 1/4' _ 1 -0" - I L 0 1 r \� - — I I!! MW r t# ,; � I I r- i1 , L U ! 1 � ' 4 , 1. + 01 Cb 7--1 I II Si STORE SIGNAGE u 9 4 E1- 4 REAIN ROOM r + r m4.1 16 J tr- I r- I 0 LL : rT ,72. = rr M PANEL I r T - 1 r ij F T .. ,I FEEDER TO � F — , L e CTRIc ROOM —4 i - { e _ - 01- _ _� � iE) +TOT w 1 tom, i 7ELE/DATA 6 L CLG r a . 1 1 AC UNIT' (ON BOVE 1 1 1 1 1 _ J.. -L _ ' L -4 1 I• r r 7 4, HyAC CONTROLS I w_ _J L-'- .�. - © ` 1 .<-- x.- . - ... -- € ---14 - -1. -- i4 ---N -- - -4,--- --,( * ---ci- - I 1 r I ..--.--.--, . - ;__ -; 1 1 1 1 I 1 1 1 1 1 1 -r -i r - e " -r 1 _ 1__; ; 1--- • i I WATER TANK r } HVAC CONTROLS ROOM '4 i \ - I 11 1 alp 1 "re We dins Ali i r aim 1 I ( ` s I' -r { TA • TO MAIN ELECTRICAL ROOM AN 2020 itU Lt) 0 RECEIVED r/TV ( r »novtl a DEC ? ;; 2003 PERMIT CENTER SEPARATE PERMIT AND APPROVAL 11111)01 � FpUIRED RMIT 12122/03 1060 No* 30 SW Seal Wail orlon 118103 Teleplay 306.675.6151 Face m . 3061175.9150 .a..,.r.olr1 SOUTHCENTER 1115 Southcenter Mal Tukwila, WA 98188 K C L S Connection at Southcenter Permit Drawings SOUTHCENTER 1115 Southcenter Mall Seattle, WA 98188 Drawn by: LE$ Checked: Dew Scale: No. Dale Remarks DEMOLTION PLAN E1.0 W 1 EXPIRES 1 -17-04 Ja8 1/4' S ■Q' • 11 o r L7 (TYP) to DJ /CABLE BRIDGE 'TRUSS STATION DESKTOP SIMPLEX RECEPTACLE FOR CONNECTION OF Tin L7 FIXTURE (TYPICAL) FURNITURE SUPPLIED WTH (3) SEPARATE BOX LOCATIONS PER SIDE A4I FURNITURE SYSTEM DETAIL SCALE: NONE EXISTING AC UNIT ON ROOF 0 f rm, 1 k..." I I / LCS SCO `s- ( 7) 0 1) sco (- r GENERAL NOTES: 1. FOR ALL INDICATED LOW VOLTAGE AND SYSTEM DEVICE LOCATIONS, ROUGH IN SHALL INCLUDE RACEWAY STUBBED INTO CEIUNG SPACE AND ROUTED TO CABLE TRAY AT APP. 18*-0. FLAG NOTES: 13> UBRARY SELF CHECKOUT: PROVIDE ROUGH—IN FOR (1) UBRARY CARD SWIPE READER AND (1) UPC SCANNER. COORDINATE EXACT REQUIREMENTS WITH EQUIPMENT PROVIDER. UBRARIAN COMPUTER STATION. UBRARY CATALOGUE STATION: PROVIDE ROUGH—IN FOR CARD CATALOGUE STATION. COORDINATE EXACT REQUIREMENTS WITH 1 --- 00 20' O+120 -----.._..4,--.71-- - ' VIP IN/ . - ._ .._. _ ' • Nr lir Igr III 1111 'V mir II 7 'Iv V' 'V 1 1/ Ilr `Ir lir ■Ir `Ir 1 1/' lir ' ' ' ' J r IV IP' 'V V' IV V' NI 11/ 7 IV 'V Vir NI NY NI 'V V V4 'V II 'V I% .4•,..... . A.. ,a, a, 4 4,,, Aih. AIL 44,. A., Ah, A., 416 ,d1,„ 4b, Ali 41... AI. Al. 411. alL 4h..416 ./b, 41. 46 4114 Ah. Al, A6 .11.■ AL .ai. Al& 46 4111. 411. 411. AL. .".4101611&10111.4 4141 C.01.414 416. 4111. AI, 411, A. .4114 III. 4IAL 44 414. 41,.. 7 9, :.,.., IVA 1 7r., in . ± .. \ /--,, ( 0 PRINTER STATION EQUIPMENT PROVIDER. [3>. POWER, TELE/DATA ROUTED IN CASEWORK. COORDINATE ALL ROUGH—IN REQUIREMENTS WITH CABINETRY DETAILS. D> PRE—FABRICATED FURNITURE SYSTEM: UNLESS NOTED OTHERVASE, (1) DUPLEX RECEPTACLE AND (1) DATA PER STATION. CONTRACTOR SHALL MAKE ALL FURNITURE CONNECTIONS AND PROVIDE DATA AND SYSTEM ROUGH—IN AS REQUIRED. ALL POWER AND DATA/SYSTEM RACEWAYS SHALL BE CONCEALED IN ARCHITECTURAL FEATURE. ALL DATA/SYSTEM RACEWAYS SHALL BE STUBBED OUT AND OVER TO CABLE TRAY. FOR ISLAND STATION. PROVIDE MC CABLE POWER EXTENSION ACROSS FURNITURE BRIDGE TRUSS. FURNITURE POWER CIRCUITS SHALL BE VARED THROUGH CONTACTOR. SEE DETAIL 1, SHEET E3.0 FOR CONTROLS a>. LAPTOP STA'TION: PROVIDE 2—CHANNEL PLUGMOLD MATH PCYMER AND DATA OUTLETS AS INDICATED IN SPECIFICATIONS. FURNITURE BRIDGE TRUSS • CABLE TRAY AFF 0 , , t "- 0 : 0 i, ,..,. --......... : / i t n 1 t ; • . ,..-- .N. , -‘, \ C , „..114.14 ,,. 0 c ., ,„ ....' ..., . , \ ....--".> - -.....---• 1 ,,.. , \ .......- / \ ......-...,--- • - i - - ..- ■ t ''', l' / .. ' ■ ..• .....• \ \ - r''. \ • \ ,....,..... / \ r , ...-,---------------- (..-..) •■.....- ... `,......," i f i 0 s'-' ' / „-- s / , \‘ / - 1 A,\ o 0 i 4 '`-- \ Ci ) . FURNITURE CONNECTION POINT. SEE: Jv sq e)+12e 0 +PCr 0 0 I HOUSE CLEAN RECEPTACLE. PROVIDE SAFETY 'TYPE. RE>. PROVIDE NEW OR EXTEND EXISTING TELE/DATA SERVICE CONNECTION PER MALL STANDARDS BACK TO MAIN ELECTRICAL ROOM TELEPHONE TERMINAL BOARD. Cr>. PLUGMOLD WITH POWER OUTLETS AS INDICATED IN SPECIFICATION& Ea> DIGITAL PROJECTION SYSTEM: PROVIDE ALL 120V CONNECTIONS AND ROUGH—IN FOR CONTROLS AND CABUNG AS REQUIRED FOR PROJECTOR AND SCREEN. COORDINATE EXACT REQUIREMENTS WITH EQUIPMENT SUPPUER. EXISTING ROOFTOP AC UNIT: EXTEND DOSING CIRCUIT MAINTAINED UNDER DEMOUTION TO NEW INDICATED ORCUIT. ASSOCIATED EXISTING DUCT DETECTOR SHUTDOWN/RESET AND CONTROLS SHALL BE MAINTAINED AND RELOCATED. EXTEND ALL RACEWAY/WRING AS REQUIRED TO NEW LOCATION. P:2>. (2) WI—A TRANSMITTERS PROVIDE 120V DEDICATED CIRCUIT AND DATA OUTLET (ALL. DEVICES MOUNTED TO CABLE TRAY). Es> PROVIDE CONNECTION FOR SIGN. SEE DETAIL 1, SHEET E3.0 LOAFOR CONTROLS. SEE ARCHITECTURAL PLANS FOR EXACT SIGN CTIONS._ 13t>” PROVIDE fr,PID INSTALL MALL STANDARD SMOKE DETECTOR/STROBE (SIMPLEX). CONTRACTOR SHALL COORDINATE REQUIREMENTS WITH LANDLORD AND PURCHASE DEVICES FROM LANOLORD. [1:".:prptS 0 •-- -1 - POWER & COMM PLAN SCALE: 1/4 1.—cr tdr) READING ROOM Df EN AREA WATER ir HEATER ------ PROJECTION FILTERED INTERNET STATION (TYP 4) ' *-; - - \ .,.., - - 1. EXIS1ING AC UNIT ON ROOF 1. 1 ' .---. i - i. .- .> S . '‘ \ ‘, I 1 ,., ? i i i 1 I.- . :,... I \ - . ? . . -- ■ /v LIk . +. A rA 4 1 €0480 , 0114 1 s PANEL L1 NEW TELE/DATA BACKBOARD 4'W x 8'H FIRE RETARDENT 3/4" PLYWOOD 44- BACKUP RACEWAY/PULLSTRING FOR LV AND SYSTEMS CABUNG. ROUTE ABOVE CEILING tt) 41IP 41111 E R MI A T I ND APPROVAL REQUiRED PERMIT SET 12/22/03 1 E2.0 RECEr. Iry r T w. DEC 2 3 2 003 PMT CNTE 1050 NMI 38h Sind Sons Wellington 91103 Telephone 205.675.9151 Facsimile 2o5.6759150 vavmehkeerdelscis.com KCLS Connection at Southcenter Permit Drawings I EXP I RES 1-17-04 I SOUTHCENTER 1115 Southcenter Mal Tukwila, WA 98188 SOUTHCENTER 1115 Southcenter Mall Seattle, WA 98188 Dravn LES_ Chalet Date: 2212KIMIEL2:03 Scab: 4 114• r.o Revisions: No. Ds Ram ■■■■•••••■1. .01■■■••■• OIMMMIMM. POWER & COMM PLAN u� W FIXTURE SCHEDULE t b t c t e LAN, 9 h TYPS MAMMONISM VOLT NO, TAPS MU". FORUM WATT O 11111101111 NOTUS MSS NO. SOATALOG NO.) Li 120 1 LV iiitle 75W Bectronio <10611H1) 75 ladtdbotteul Pendent fixture. Self contained low vamps trensionner Complete with el mounting limbers and esessearbe. L2 Juno Medical CF. IPL002EU 120 1 111. 01T Electrode <101ITHD 20 Illsommed compact fluoresces.* doesoliglit. 6-5/5° nominal diameter. with ultra-trim while baffle. Tech Lighting Manor Truck *stem MN, MN - - 25 Specialty 12V low voltage buck erliem. Suppled complete with iodated truck 3O01 low woltoge bansfornwr and oil mounting heremee and aocemories au required. Furnished owner. bstelled contractor. . listed beer foot for cede cakulotions Toth Liglabulp Curtsy Torpedo 120 1 LV 11R10 5Ati 50 Specialty low vases buck itchwe. Famished and Metaled by owner. L4 Tech Lighting Aero - Thdterbell 120 1 LV 110111 SOW 50 Specialty low mikes buck Rebus. Furnished and buriolled by ownsr. LZ NOT USED LIT Tech Lighting Atrial Cloud Track *stern - - - - 300 Specialty 12V law voltage brook oplero. Suppled cemplete with Jadeite) book. 300bto mita,* transformer and all moonlit* hardware and eocamodse as required. Furnished W owner. bieblied W oentrochor. Tech Lighting To be delermined 120 1 201/ 111-Pin Per Rider* - 20 Mind Suture Wes to be determined. Furnished and Inslelled by wow. L7 n.i NW* Flood /W-DLX MI 120 1 Li/ 1111t16 7fIN 75 Mosby elyle spotlight. Itikinkoorn bombs esif oentebed low volley Clump mount with ph* in Gerd oenneoler. MIS Pendent 141932 120 1 FAN 11tT Electrenic ciOSTIM 24 Ardranabind Coselyer Pendent Rohm Sidle polled maid 4101 glees dIffuww bran end lbw 1.. USiono La Towles 120 2 32W Tli Deobonkt <101ERID 10 Nem, Bo* Swim* Wrap Pendent. Prismatic awille ism PAW, web sulleide pendent men, hereuere or o-doonosI meant where N� maw mist L10 120 3 ram/1W Eleciterdc <1010$0 72 Osetom Vetoed Wit Rehm ILi 1 120 . 1 F1415 Ontrasio c1010111) 20 Lifter *Ip I'M integre, le furniture. Fterdelled end Inetelled by owner. •armisriesesov . xi Liphloiler LT Serbs 120 UM 5 .- 1 . ram - arm ca VW pelyeerbenete hewing wIlls eland! fine. Newel Need by for emeriencp - 1-- - t AL ICA= 01104.00 MINIM RIM" A OESION MS ONLY MD CORRESPOND 10 1E UPC IIPOMFACTIAERS Spa NUR. AL OPTIONS, AOCESIONES MD/OR MIAS COMPONENTS NW IMT SE RIPLIORD IN TOGS MASER NO 001 lialIONIMILI FOR PROVIDING AL SUCH NOM ONICIOSIII IN PURSE DISCRIPRON MD/OR SPECIFICATIONS. SUSINVIURON OF MIRE TAM MIL MILY SE POMP= IF PICNIXIENICS. CONSIRUCION/CONPONENT OMIT SIM at _i INIMIIIITY ME MOM TO OE SPX TO 114E 001C41 MUT. AWL ORICRETION TO SE DERININED SY DIP L 111111111111110111 MILL MANE PIOXWEIRICS NO SE NICOIND (5) 1110111NENS OAVS MR TO MOMS KM INGINISNING NM= IL PROM COLD IIVINEN MUMS FOR ALL °MOON ROMMEL Ii. AL PLUOREICINT NO NID MAPS FNMA= SMALL IS MONO MN IN-U LP rum ' CONFIWOOR TO min cams =swam FON PRIM SIOUNIIMI NINENNE 7 21111 • . M M V S l 1 1 OUE mums at OM OM OM ME WI 111,11111 1111111111F M MEN 1W WINN. L t a t b t c t e t f 9 h • ■••■•■•■•■ 1 • ; I ; I ! ; 11 I: I L1 1; I , , 1 '\ \( ii , \ i• 1 k , s. • // I t I ‘\\,,•`'— ' \ '- ......-/ ." 1 -------- ‘.-- .. --. ...- 4.- , — ---,--; • - t - i i I 6 • I I I 11 1 I i ; I I • 1 1 1 i I , i i I 1 . i / i i ; I I 13 x1 i i i i'll :1:0/ 1 It I t 1 l l i le l) 1 P .1 \ , ! i i ; i ! I ■ I I ' / ' ; ,r'. L I. „ . 4 24 ■.-.,' Hi Ir. - ! , 1 1 1 ---''' i 1 4 r 7 \ I 0 I l ! : r II‘ il, ,, --1- -4-", 1111 i i 1 1 , I I . 't . r t, -- i 1 1 I I • 1 1 ; 1 i ! ;11 • , 1 ! _ „,' 1 , ; i' 1 i ! i , ; ' . . •---", 1 1 I • I I '...4 ,..).- .., , Th,;..--i- ! i ■ : ; 1 -..., ... r.... it ! d ( . • 4 • 1 ! ! 1 ' •; I ' I ; 1 ; H Ll 1 I _It 1 ' I LJJ i 1 L_ _ ___ i 1 , _ -771 H 1 ' . ' i L 4 ---------- - -1---- - - - - -- L- ~". -- - - - . v- FT Ili0--i >4 ; I , . -,,, -7-..K.,.-.. ...... : ! 1 1 1 1 f ; i I L10 ; r -11----i- ; ; ; ! I ! I ' t ! i ! ! , 1 -------- " - 1 I ..1rtf I t ; 1 1 1 • ; 1 .„..:.„,.,....,.., 1 _ a 0 .._ !,... r_ ,A,,,:.::_ i ! V 1 i 0 1 I i ')\‘‘. ; . l,_____ , ; 7-----s - . / 1 \ : ...,,,,.......,;, • .. r ' 1 ! , i L „:, Isi... fi t : ,......,. i (-- ..4,-1 '. IS ,, , / , - _-______, -, ' 1 ' kr---„,.. ....„----\ \ ; -... . I )....c.---.. .-"----K f 1 \ 1 M / [I ________ .,,.....A___ 1 1 \ (7) ,, 0 • i 1 • ,.. , -- i.7 7 ...._. ....) ii L I ci (TYR ALt.; TypE trr !I i ( 7i i 8,, L7 ; 0 ; i 1.. . ; 1 LII i *LS I I \ I : i ! ‘ —0" (TYP) : ! 1 i 1 . _ 1 t • \ FIXTURE IS ATTACHED TO FURNITURE PARTITION SUPPORT SYSTEM VIA CLAMP MOUNT AND IS FURNISHED WITH CORD/PLUG. [Z>.. NE1V FIXIURE IN EXISTING LOCATION. D>. TIME CLOCK AND CONTACTOR FOR IGHTING AND SIGNS. SEE DETAILS 1 AND 2, THIS SHEET. 1:3>. PROVIDE 120V CONTACTOR WITH POLES AS REQUIRED. ; — 1 I 11 I ! 0 I; \ L7 ; .. ___ •••-, 1 i H. L11 I. I I i I 1 SCALE: 1f4 LIGHTINgi PLAN fb --- I `--z ; 1 I ' , ; 1 ft ..:.— -----z-.... v ,, , „,,,. ,. .........„,_..,:.„,..—• A o 7 r ' .4, , ,( LI 0 i \-----41 / r , •La 1 0 I ! 0 I I ' 1.2 ; I 12 „ I ; 1, I - • - I L . i ! ! ! L-4.--- - - — t 1 . • : 1 ' . - .— ---- 1 ! 1 , , ! 1 i 1.........:.■ . --;.- - .1 - _.-,.., .. ' ' I I 0 0u ! 1 bi..■.± ...._.."- . - 1 0 1 0 1 O ; I- 0 u ; 1 -12.,------i-----42 I 1 u , 1 L2 LA . . i I , ' 1 ; ________ 4.___i_ • _____. _ _________ I.... - 1 ,------I I 1 ! ; 1 ------ -i : I - --,--- 1 ._..___ ...t.••-- • , . ! 1 CEILING 4EIGHT! , , i 10*-0" ![ ; i ......• _ _ .... 1 1 , 1 1 . ; . 1 ; 1 , , • .... ; 1 I ' r . 4 : 1-- 4- -- _i__ _ ___ , ;.. _. ....: I 01 I 0 1 ; I . 1 • - : 1 t--_-4A I ; I 0 1.---- -9, ,„ 1 1 I , -_ , '-_____ ....4.......... j I 12 L2 I I I ;"12 O 0, ,,, 1 1 ....._A-___..L............_4 , 1----- i i !---! , , ......... , 1 , , i I — Ii • 1 ■ I . ' j , : .......---...- fi ' tt , , 1 .-.4 . i 1 i i o 11 i i I . \ . . • ti , , ', ...j \ 1 1 • . ; ; --, ! -- -, - - - i --",.., 1 1' '44 . ;:.._ ,... i —., -- ' , -------- , I 4 . , I 7 i r ' ! , I! 1 , .' -1--- -- -- - - ---- 1 ---- tTL:=. - .11 - -1 .-----1 - -._; ' - -i--, I • ...._ ! n I I • L2 f • o ■ , 1 / ! i I ! Ti o ..... f -.' ..". • 1 / O i s , --------i----+---- -- --. -t---- -.-- .---1.i ----- - — - 4-,'.-- ' . i , . 4 , ; , , 1 ! o I u : L2; • t i l i .3 12 . i 1 1 '1•---; ; 1 ; : , , , • I ; I ! i 1 ; o ; • h 0 . 1 1 , t I ! , , , ----1-\ I 1-2I: 1 t 12 ' -.- I ; ! t 1 i ,I 1 - — I , \ : II j it 1 . , , 1 , , 1 i o ! O, ; 1 0 1 o ',. ' o I ' ". 1 0 I f ,,‘ L2 ; 1 ' , 1 o ; 1 1 J ., ; , t i • I I —1___ ___ ____1 u ca 9 u i 1 i S°FFer , • a – ENTRY 4k MMN PENDANT FIXTURES b – SYSTEM FURNITURE UGHTS c – UNARY BACK DESK d – CHILDREN'S AREA CAN UGHTS – CHILDREN'S AREA TRACK UGHTING f – 11100KSHaF LIGHTING 9 – ILLUMINATED SIGNS h SYSTEM FURNITURE POWER minim SWITCHBANK 1.• NO SCALE PANEL Li 3 5 / 0 1 SIONASII CONTROL ••• I I I , I , l'. 1 'I , I • i t 0 N Lti -N 1! 1 PANEL L1 2 PANEL L1 'TIME CI,MICK} CONTACTOR BACKUP UPS/BATTERY OPEN STRUCTURE CEIUNG HEIGHT 19•-0• CITY OF TifiCiiiLA APPROvt.D JAN 2 0 2004 A ivu tu BUIL Dikri-EA410 — - w SY•TIM PURNITUMIE CONTROL SYS1D1 FURNII1URE POSER SYS1EM FURNITURE POWER SYSTEM FURPITURE POIER FURNI1URE PovER SYSTEM FURNrTURE POWER IF SYSTEM FURNITURE POVER RECEIVED rrs rI 1.! WI' 4 1 • 0 E C 2 3 2003 PERM.' ..."ENTEF, is SFPARATE PERMIT AND TA APPROVAL L ERMIT 1060 Nest 31IM : - - salle Washinolon 9E103 isisoione 206.675.9151 Facsimile 205.675.91M wevahltearthisclaccrn K C L S Connection at Southcenter Drawn br Chedtat Date: Swig: Revisions: No. Date 1 EXPIRES 1-17-04 *MOP•NG TOWNS SOUTHCENTER 1115 Southcenter Mall Tukwla, WA 98188 Permit Drawings X SOUTHCENTER 1115 Soutticenter Mall Seattle, WA 98188 LIGHTING PLAN E3.0 r.:0 r :: Ill II i% ill t L�ZJ L '.. «J r::�-1 r: I 1 ,_ ;I ;; M;I r � r :";� #1 it Mil #6 i M, ' � L =J L =J r7.701 r:...-1 #2 Ii'r� J 5 I: M;I r GFP r - L_,.J 1...:=J r 1 r 1 :Oki rM;, L L= =.1 L__J L�LJ z 1 r te , #3 :(M;1 •4 1(M)1 L` J L��J /�/� : p 1200.9 /Jr' TENANT 3 DISCONNECTS --•� 11 001 10012001200120011001 1 2 3 4 5 6 T— MOBILE • • 2 4-3/O. PG GENERAL NQ.IE$: EXISTING 1200A MAIN SWITCHBOARD 208/120V, 30, 4W MANUFACTURER: CHALLENGER LOCATION: PERIMETER ELECTRIC ROOM, SEE E0.0 PARTIAL ONE -LINE DIAGRAM SCALE: NONE 1. ALL DISTRIBUTION EQUIPMENT IS EXISTING. ASSUMPTION IS MADE THAT TENANT IS ALLOWED UP TO FULL 200A CAPACITY BASED ON LANDLORD/TENANT CONTRACT AND THAT SERVICE DISTRIBUTION IS DESIGNED TO CARRY TENANT LOAD. LOAD CALCULATIONS BACK TO UTIUTY SERVICE POINT ARE NOT INCLUDED UNDER THIS CONTRACT. 2. ALL TENANT MIRING TO BE COPPER AND INSTALLED IN ELECTRICAL METALLIC TUBING (EMT). PVC RACEWAY NOT ALLOWED EXCEPT FOR IN SLAB OR UNDER GROUND INSTALLATION. 3. PROVIDE COPY OF FINAL LOAD INFORMATION TO LANDLORD MALL OPERATIONS UPON COMPLETION OF WORK. FLAG NQTES: �• PSE METER #ze725697& rove METER, PROVIDE BLANK COVER OR MAKE SPARE PER SERVING UTILITY REQUIREMENTS. REMOVE DOSING "AIRES' TENANT FEEDER BACK TO SOURCE. REMOVE TENANT PANEL_ REMOVE RACEWAY BACK TO AND STUB INTO ADJACENT SERVICE CORRIDOR OR AOCESSIOIE GENERAL CEILING SPACE DO NOT LEAVE RACEWAY M ANY TENANT SPACE UNLESS AUTHORIZED TO DO 90 BY MALL MANAGEMENT. Dr>. PSE METER 11Z6472619Et METER TO BE MAINTAINED AND USED TO SERVE NEW LIBRARY TENANT PANEL. ED> INTERCEPT AND EXTEND TENANT FEEDER/RACEWAY TO PEW TENANT PANEL. PSE UTIUTY 1)baxi3 0 r • CITY GE TUKCrr►LA APPKOvtu JAN 2 0 2004 AJ iiuitU BUILDING DIVISION PECEI'.ED "+'r (1F TI jKW+ a DEC 2. 3 2 003 PERM +' CENTEF SEPARATE PERMIT AND APPROVAL 4911; REQUIRED PERMIT SET 12172103 • 1060 No 30 Still Mee WsMwplon 91103 Telephone 205.675.9151 Facsimile 206.675.9150 rww K C L S Connection at Sduthcenter Permit Drawings Drawn by: Checked: Dal: Scare: Revisions: No. Da s Remade W ( EXPIRES 1 -17-04 I SOUTHCENTER 1115 SoutlhceMer Mel Tukwila, WA 98188 SOUTHCENTER 1115 Southcenler Mall Seattle, WA 981 LES 22Darw w.2Qo3 RISER DIAGRAM SCHEDULES E4.0 J • �1