Loading...
HomeMy WebLinkAboutPermit B92-0002 - BASEBALL WORLD - RESTROOM AND OFFICEb92-0002 baseball world 319 tukwila parkway bk6EBA LL \IVDIZL CITY OF TUKWILA 6300 SOUTHCENTER'BOULEVARD, SUITE 100 TUKWILA, WASJ{IN.G;TON 98188 CERTIFICATE OF OCCUPANCY THIS CERTIFICATE ISSUE,P ' PURS` TQ +'HE ,REQ 4T ��OF SEC1 I 307 OF THE UNIFORM BUILDING CI CE a TI YIN t THAT AT THE' °TIME�'OF IS ,THIS STRUCTURE • WAS IN COMPLIANC ti �TH VE ar THARIOUS0ORD IhANCt5z THE REGULATING BUILDING . APPL`ICABL \CITY FIR " CODES, { F E ANDAL TH OLLOWING F t/ ,,i,• to -,0"'' .g. 1 w s« ` M Vi. i sr . A ` � - a of a j ( S , �" 6 •;r , . : r Te n ' t 'BASEBALL WORL ` ; 1 : . t F . Per'mj t No*"B 002 Building Ad , , 'ss '19 TU�ICWILA, Y ,,.. °' `'y' Pa 443'223,00-0010 1 , Q ne.. : §OUTHCENTER—'ANNEX' j SSOG " "` "' `' •4tt +•M '•r�� 3 `# I y rte :... 7' '' ��JA '.� a•4ei�t r...�,� r,'t Q0 .upancy• ,TORE ,+ 4, M Occupant LQ,a'# Occupy Gr�,ou} : B -2, j \, ..b Type , T� ,} 4 T e of ,ions o f y J 1 t k k BATH'OOM AND WALLS FOR FFI.cE USE DAT. : A� 1i:r�inh TYPE •F •N •: 111—N UB EDI I S" (year) 1988 SETBACKS: N— S— E— W— FIRE PROTECTION: Sprinklers ❑ Detectors 0 N/A UTILITY PERMITS REQUIRED? ❑Yes 50 No BAR /LAND USE CONDITIONS? 0 Yes (througl, Public Worksl 0 N ZONING: CONDITIONS (other than those noted on or attached to permit/plans) WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT 11 ADDRESS PROPERTY OWNER Southcenter Associates PHONE 454 - 6120 ADDRESS 201 116th Avenue N.B. , Bellevue, WA DP 98004 CONTRACTOR Owner PHONE ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT PHONE ADDRESS ZIP DATE ISSUED: SITE ADDRESS USE ;--1 B 7-2 SQUARE OCC. SQUARE FEET LOAD FEET irs permit sha issuance, or t CERTIFICATE OF OCCUPANCY NO. CITY OF TUKWILA Dept. of Community Development- Building Divisio 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDING PERMIT NO. (59 a'rJ0oa DESCRIBE WORK TO BE DONE: Install bathroom and office. SIGNATURE: ,66—c i eJer -rte PRINT NAME: ,7"..)/0. ,G .a6 ✓2 icome'nu an e wo rk ` is . suspen, ora BUILDING PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) RCPT: V. 'OA >552 is DATE::: BUILDING :PERMIT FEE:;: PLANCHECK FEE BUILDING:;SURCHARGEI OTHER• 92 PLAN CHECK NO.: B92 -0002 PROJECT.' INFOi�IUIA'TION VALUE OF CONSTRUCTION - $ 319 Tukwila Py 2,000.00 SUITE # PROJECTNAMEirENANT Baseball World, Inc. ASSESSOR ACCOUNT # 022300 - 0010 -09 TYPE OF U New Building U Addition (x) Tenant Improvement (commercial) U Demolition (building) [] Grading/Fill WORK: ❑ Rack Storage 0 Reroof ❑ Remodel (residential) ❑ Other: CODE COMPLIANCE FLOOR.: 2,464 71 OCC. SQUARE OCC. SQUARE LOAD FEET LOAD FEET OCC. LOAD SQUARE OCC. FEET LOAD TOTAL SQUARE FEET 2,464 2,464 TOTAL OCC. LOAD 71 71 BUILDING OFFICIAL DATE: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. DATE: /2- -- 73/''e/x1- y' / 9 c 9 COMPANY: 47 ac/a �pu�li c l �S5 c! e work rs not commenced with 18 0 days from the; day andoned :for a periodof 1;80 days from th ':last rn DATE ISSUED: uirra+w PERMIT NO. CONTACTED v 12_ DATE READY DATE NOTIFIED BY: 4 PERMIT EXPIRES 2nd NOTIFICATION 3RD NOTIFICATION BY: (init.) BY: (init.) AMOUNT OWING - --f' SITE ADDRESS BUILDING ERMIT APPLICATION TRACKING PROJECT NAME boil World INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC, LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. TOTAL OCC. LOAD U1REME ME hI�'' ,BUILDING - initial review N �• ) ROUTED 4102 2r- CONSULTANT: Date Sent Date Approved - Pj • Detectors FIRE PROTECTION: FIRE DEPT. LETTER DATED: INSPECTOR: N/A FIRE O PLANNING O PUBLIC WORKS O OTHER REVIEW COMPLETED INIT: INIT: ZONING: ----- ]BAR/LAND USE CONDITIONS? REFERENCE FILE NOS.: MINIMUM SETBACKS: N- PUBLIC WORKS LETTER DATED: S. UTILITY PERMITS REQUIRED? Yes (BUILDING - IttZ I t FEB ciZ TYPE OF CONSTRUCTION: UBC EDITION (year): final review INIT: �� tit"" “ 1 Yes (1 No 08/17/80 :4:.i.:;tiglIEB G;5,RT(FY.:T.tiAT :4:11'AV.EiE R , �y}�y , Y��7� 1 I:; AMINED ::Tl'if a F Yr. ,. I .. ..T.n 1Il�lill t^•�' , ; A'Cl4N�: AN , . , ... : ", � E �A bi•:.AM AUTH�l�tI�E .'�Oi�,ApPk ��FA P Yy� • I TRUE•AND , R R CT ;' M `N' •f D.' .1 I . Y•. M :'��I� I.I -:.KNCjW.:iT�i F,�,;:•�AM , .•.. .I ir. II '. ;, *• . /: Y'.nn .I<•11.. :IIY.�I�.1. •rY..A..l v'1 DATE BUILDING OWNER AUTHORIZED AGENT CONTACT PERSON SIGNATURE e.47 PAINTNAME David E. Edwards. Jr PHONE454 -6120 WILL THERE BE A CHANGE IN USE? M No 0 Yes If Yes, new building requirements may need to be met. Please explain: ADDRESS 201 11 th N.E. Berle-Niue, wA CITY/ZIP Bellevue 98004 Dave Edwards PHONE 7'P 98004 : :. :0ESCFi •.TI• : ; PROJECT NAME/TENANT 1 ASSESSOR ACCOUNT # Baseball World, Inc. 022300 - 0010 -09 AMOUNT.:,.; RCP.' # v; :.;R,DAT6,:':.;• BUJLDING:PERMITFEE WILL THERE BE A CHANGE IN USE? M No 0 Yes If Yes, new building requirements may need to be met. Please explain: r :s s WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? ® No 0 Yes IFYES, EXPLAIN: PRO PER OWNER Armada /Southcenter Associates PHONE�4 --T PLAN :CHECKFEE:. 7'P 98004 CONTRACTOR - ' Zi BUILDiN U-Cil'RQ :.,..,:,icc�:.•I ( �r/ / S,, ; ADDRESS :: ' :;;.:. Q ,THERf'.'.4•. .Y •M• . : 1. .I Nl. . ... ..tv 1 'I.Y : f • .y i: • : ..Yi N•. 111. :::::....., .;. .. .. : ;:.......I . TOTAL' :J' `"l. SITE ADDRESS SUITE # I VALUE OF CONSTRUCTION • $ ; ' i , '%c, " ( 0 , Q 319 Tukwila Parkway, Tukwila, WA 98188 � $2,000.00 PROJECT NAME/TENANT 1 ASSESSOR ACCOUNT # Baseball World, Inc. 022300 - 0010 -09 TYPE OF New Building 0 Addition X Tenant improvement (commercial) U Demolition (building) WORK: • Rack Storms 0 Reroof R m el (residential) CD Other: DESCRIBE WORK TO BE DONE: Install bathroom and office +� - BUILDING USE (office, warehouse, etc.) Retail NATURE OF BUSINESS: Retail Baseball Cards WILL THERE BE A CHANGE IN USE? M No 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE • Building: 39 , 074 Tenant Space: 2464 Area of Construction: NW Corner WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? ® No 0 Yes IFYES, EXPLAIN: PRO PER OWNER Armada /Southcenter Associates PHONE�4 --T ADDRESS 201 116th Avenue N.E. Be WA 7'P 98004 CONTRACTOR PHONE ADDRESS Zi WA, ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT None PHONE ADDRESS PP 12/28.'91 11:59 FAX 205' 11 3865 CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431.3670 'PLAN CHECK NUMBER c - Vc TUK PUB WORKS LOU COZZETTI Q1002 BUILDING PERMIT APPLICATION APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form, Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new constriction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. in all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and Is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/encineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent ,o submit this perm :t application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations, The building official may extend the time for action by the applicant for a period not exceeding 160 days upon written request by the applicant as defined In Section 304(d) of the Uniform Building Code (current edition), No application shall be extended more than once. if you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES V ec • I Type ' Inspe« I : Dt Pt' K. I.te a e.: .3_ 4 9. c>._ al Instructions:. Date Wanted: s ......am p.m. Requester: 1 Phone No.: MOP M INSPECTION RECORD ( a copy with permit INSPECTION NO. P CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 �_ —_; 06) 431 -3670 Inspector: Approved per applicable codes. COMMENTS 4-0 ❑ Corrections required prior to approval. Date: $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection: eceipt o. : '' COMMENTS: ' d on: p ype o nspect C 4 n co Address: ,31q .. ;) K W ('G. 1j arn 1•1 P (-\Arl t iC; F-t >`.i AI_ . 6■MTE' 'rt9 E' — J — _ y o "I ►2A Date Wanted: CI C- t► 1 r 1 L C r /NW) 2) P(I... (AA . Sr • t3A`t2..YLtc - "iZ. - (Lt,. REla-wirs . Li (Sy —I + & 0) a 1 c.. -"1" S te` NE1(NM— N 'i2S. 31\ 'E 17 - 19 " -sZT) cult R- . b) AOO l r.1stt � ?) To Si Nv-` () ` rZA -P. /. - A,3EL .I 2 w 11 k &AQ4t Y2. FL.c S1C,NAGQ • nG Ati' n tL. t. S E rte:, n. F ii= . (1 6 1 (✓ LE''G - ( Pi 1J Pr 4/4P FT l&q Ft N Iri- -- w -L 1 NM) i tiA CE ArrlAch rqt ",c-t) 1././Pct., . IS EVAA:VE ..( ev■ L ) l roe ��� ll.)C�Y ` � d on: p ype o nspect C 4 n co Address: ,31q .. ;) K W ('G. 1j Date Called: — J — _ y o "I Special Instructions: •„/ 2 0 6 , 1 d z— Date Wanted: `"� 1 `� " am. p.m. Requester: m,e_. Ed war cb Phone No.: Li (Sy —I + & 0) Inspector: -0 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 O Approved per applicable codes. (206) 431 -3670 K Corrections required prior to approval. 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: ' 5) ff-bv of) q: A 1.19 S (4 C'Stom,IT K�= vISVIP P (/M M - / Z S No ■ N l v t . C i ''A -A 6vo t..- '` C ) o_ -t.4 \4..S , l H or wW-T - 7z - TA-r.t 1t- W t` A Address: ' 1L e 3i 9 e led: Date Called; vA-L.V� JS Sod u SA-5 i /i-eP /1"W ! & NtiJ t r:16 I 01 A P1- toFnr..61rJ -, ✓e1\1T W f S / LL.erlitt.. J r" tm UST" • 0r w )4 R I L-L '1`O 7 r o v..'r t 0 e . Q K.. .) R tvi P P rr z, vi .D� t) La c rJ m . '1 G L A a-O k ►J9 iSA -N1 It-n•ntN ►=- tcmr2.. R Requesuester: Phone No.: Project: " Pr -1, Lt 9 � o on: N Fl Address: ' 1L e 3i 9 e led: Date Called; Special Instructions: ea .. Z O r anted: � . 7 -.. s. ,C 2- am. p.m. R Requesuester: Phone No.: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 Approved per applicable codes. Date: - J O $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: .0 INSPECTION RECORD 0 Retain a copy with permit [Date: 0 2--: PERMfT (206) 431 -3670 CCorrections required prior to approval. ro act: i , / few I ype of Inspe ' -teCa es: 10'. isr _ - /3 --- / a Add .� u,�u�� /�— s— p - gla structions: f Date Wanted: 3 '-' /G qZ m . m. Requester: Phone 0 INSPECTION RECORD 0 Retain a copy with permit I S' ECTiM` `0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 Approved per. applicable codes. COMMENTS: Inspector: ❑ Corrections required prior to approval. ❑ $30. REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No.: e: P roject: 1 _ k) � %�� type 0 nspection:F i L_ Address: Date Called; Special Instructions: Date Wanted: � q�i am. p.m. Requester: Eon Phone No.: 434-6 (Za Approved :per applicable codes. COMMENTS: C INSPECTION RECORD 0 Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT N (206) 431 -3670 0 Corrections required prior to approval. O LAK 0 A , bi-QA''s•-• 4- n C7 $30.00 FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. yy� „ i�SfC r ir. ro'�„�'Y:'l�4 }.:,J 4� ;)K:a,?�es+ksa.• ^,� L City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Project Name Address Retain current inspection schedule Needs shift inspection TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM �'�.t�,tlFtiS t �k .'�`vt r .:;ai•�i'r;��,, , ti.b...lt't 3''+;:? .i: 4 ..''i• 71.717..- 19:56 /f 1 L J.t?,d .Z Suite # Gary L. VanDusen, Mayor Control No . 3f Permit No. • • Aut or ze Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: • A/ Halon: Monitor: Pre-Fire: 4/ Permits: nature FINALAPP.FRM . T.F.D. Form F.P. 85 "X" REQUIRED INSPECTIONS PHONE DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 R 7 Framing 431 -3670 R 8 Insulation 431 -3670 X 9 Suspended Ceiling 431 -3670 X 10 Wall Board Fastening 431 -3670 11 12 13 X 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 x 17 BUILDING FINAL 431 -3670 CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: 319 Tukwila Py BUILDIK3 PERMIT INSPECTION RECORD (Post with Building Permit in conspicuous place) SUITE NO.: BUILDING PERMIT NO. O DATE ISSUED: PROJECT: Baseball World, Inc. CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (INSPECTOR COMMENT SECTION ON REVERSE) INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. 09/440 PROJECT NAME ADDRESS CONTACT PERSON CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * * REVISION SUBMITTAL * * DATE January 27, 1992 in the store. Baseball World, Inc. 319 Tukwila Parkway, Tukwila, Washington 98188 Dave Edwards ARCHITECT OR ENGINEER Own e r PERMIT NUMBER n /a (If previously issued) PLAN CHECK NUMBER B -92 -0002 TYPE OF REVISION: 1. Revised exiting from premises. 2. Details of bathroom facilities. SHEETNUMBER(S) one (revised 1 /22/92) "Cloud" or highlight all areas of revisions and date revisions. PHONE 454 -6120 3. There will be a maximum of three employees at any one time SUBM1TI'ED TO: Robert Benedicto RECEIVED Pmv OF TUKWIlA JAN 2 s§ Poonnrcewirem July 14, 1992 Dear Ms. Bates: Shelley Bates City of Tukwila Building Division 6300 Southcenter Blvd. #100 Tukwila, WA 98188 RE: Baseball World 319 Tukwila Parkway Tukwila, WA Permit #B92-0002 • /3 ETA COMMERCIAL PROPERTIES, INC. An inspection was made on the above referenced location on July 8, 1992. One: �f the items requested was an "as built" plan of the restroom be submitted to your department. Enclosed is the "as built" for your records Pryou questions, please call Me-. Thank .you. SincerelY, •'Ginny Christofferson jgc 201 - 116TH AVE, N,E., BELLEVUE, WA 98004 / (206) 454-6120 RECEIVED CITv OF TUKWILA JUL 16 1992 PERMIT CENTER Address: 319 TUKWILA PY Tenant: BASEBALL WORLD, INC. Type: B -BUILD Parcel #: 022300 -0010 CITY OF TUKWILA Permit No: B92 -0002 Status: ISSUED Applied: 01/07/1992 Issued: 02/12/1992 **************** k*********************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** *off ** Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296- 4722). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical . work will be inspected by that agency (277- 7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. 5. All permits, inspection records, and approved plans shall be maintained available at the job site prior to the start of any construction. These documents are to be maintained available until final inspection approval is granted. 6. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 7. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 8. Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identi- fication showing the fire performance rating thereof. 9. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1991 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 10. Provide toilet room exhaust fan ducted to exterior of building. 11. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 12. A CERTIFICATE OF OCCUPANCY WILL BE REQUIRED FOR THIS PERMIT. City of Tukwila N111L4 FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review Control #B92 -002 Re: Baseball World - 319 Tukwila Parkway Dear Sir: February 5, 1992 John W. Rants, Mayor The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in . the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA .10, 1 -6.3) (UFC 10.505A) 2. Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 12.106 - 12.111) Exit doors shall be openable from the inside without . the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 12.106(c)) City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 2 Exits serving more than 50 people must be provided with illuminated exit signs. (UFC 12.108(d)) a John W. Rants, Mayor Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 3304(b)) 3. Maintain sprinkler protection for all enclosed areas. (NFPA 13, 4- 1.1.1) (UFC 10.302) All sprinkler drawings shall be prepared by companies licensed to perform this type of work. Drawings shall first be approved by the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528 & NFPA 13, 1 -9.1) (UFC 10.305) 4. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 10.208) All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) All interior wall covering materials shall be fire- resistive or shall be treated to be fire- resistive, so as to result in a flame - spread rating as required by UFC Appendix VI -C tables 42A and 42B. A certificate of the flame spread rating is, required to be delivered to the Tukwila Fire Department. (UBC 4204) (UFC: 10.40.1) ,a;1 vr /W CITY OF TUKWILA BUILDING DIVISION MEMO • TO: B92-0002 BASEBALL WORLD FROM: RSB DATE:2 /4/92 SUBJECT: REVISION SUBMITTAL *********** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1. EXITING: APPLICANT REVISED PLAN TO SHOW EXTENT OF RETAIL SALES FLOOR AND TO ADD A SECOND EXIT. DIAGONAL DISTANCE OF AREA TO BE SERVED = 54'/2 = 27 ' MIN SEP BTWN EXIT DOORS. SECOND EXIT HAS BEEN LOCATED IN EXISTING STOREFRONT WHERE DOOR FRAMING EXISTS. THIS PROVIDES A SEPARATION OF 26 FEET FROM JAMB TO JAMB, OR 3% < MINIMUM. EXITING O.K. 2. BATHROOM FACILITIES REVISED TO MEET BARRIER FREE REQMTS FOR CLEARANCES. O.K. 3. LETTER FROM OWNER IN FILE INDICATING THAT THREE EMPLOYEES. WILL BE PRESENT AT ONE TIME ON PREMISES. ONE TOILET FACILITY O.K. ROUTE TO FIRE PREVENTION BUREAU THIS DATE. City of Tukwila 'Planning Department Tukwila , ,Wash.. 9 818 8. To whom it may concern; As ..requested, this letter shall serve' to :.confirm that our retail store located at 319 Tukwila Parkway will not be staffed by more than three employees at a time, not to include the owners. aseball :World' Inc • 4621 'Airport Way S. • Seattle, WA 98108 • Seattle (206) 682 -1160 m Tacoma (206) 565-5154 DATE: 1/21/92 Sincerely, PLAN REVIEW NO. B92 -0002 PROJECT: BASEBALL WORLD, INC. CONTACT: Mr. David Edwards, Jr. 201 - 116th NE Bellevue, WA 98004 RE: Plan review comments Dear Mr. Edwards: Robert Benedicto, Plans Examiner CITY OF TUKWILA * BUILDING DIVISION * The initial plan review has been completed by Building Division, and the following corrections or clarifications are required to show compliance with The Uniform Building Code and The Washington State Regulations for Barrier Free Facilities. 1. The retail sales floor serves an occupant load such that two exits are required. Please review space plan and provide a second exit. Note that the two exits must be separated by no less than one half the largest diagonal distance of the space served. 2. The proposed bathroom facility must be made to comply with the Washington State Barrier Free Code. Provide details to show compliance, i.e. fixture locations, dimensions and door size and direction of swing. 3. If this business will employ four or more workers, then facilities for each sex must be provided. Please respond to the listed comments in itemized letter form and submit two copies of all revised plans that are developed. If you have any questions, you may call this office at 206/431 - 3670, weekdays between 8:30 AM and 5:00 PM. baseball world restroom plan plan