HomeMy WebLinkAboutPermit B92-0061 - MUSEUM OF FLIGHT - CHALLENGER LEARNING CENTER EXHIBITb92-0061 museum of flight 9404 east marginal way south mu3Eu.m OF LIGHT City of Thk l (206) 431 -3690 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: B92 -0061 Status: ISSUED Type: B -BUILD Issued: 03/12/1992 Category: ACOM Expires: 09/08/1992 Address: 9404 EAST MARGINAL WY S Location: Parcel #: 332404 -9019 Zoning: Type Const: II -1 HR Gas /Elec: Wetlands: 0 Water: N/A Signature Print Name:21e. 7v-1A_ L2ckez/ BUILDING PERMIT Type of Occupancy: Slopes: 0 Sewer: N/A TENANT .MUSEUM OF FLIGHT Phone: 206 764 -5700 9404 EAST MARGINALAWAY SOUTH, SEATTLE, WA , , 98108 OWNER MUSEUM OF FLIGHT:.FOUNDATIO 9404 E MARGINAL WAYS 07024 - 00 , SEATTLE WA , 98108 ARCHITECT GREGOV ARCHITECTS`' .. Phone: 206 622 -6990 1218 THIRD AVENUE SUITE 1200, SEATTLE,.W , , 980 ************* 4(*********,**** ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * ** ** Permit Description: ADDITION OF NEW WALLS, EXIT DOORS AND FINISHES AT THE AREA ADJACENT TO THE GREAT GALLERY TO ACCOMMODATE THE CHALLENGER LEARNING CENTER EXHIBIT, Units: 000 Front: Buildings: 001 Fire Protection.: SPRINKLERED UBC Edit`i,on: 1.988 Valuation: SETBACKS Back: Right: 45,000:00 Total Permit Fee: , ,634.80 ***************.***'************** * * * * * * * * * * * * * * * * * * * * * *, * ** * * * ** Permit Center Authorized Signature I hereby certify that.`I have read and examined : this_ permit and know the same to be and correct. All provisions of law ordinances governing this work . will be complied °with, whether: spepified herein or not The granting of permit does n.ot,presume'to give „author.ity to violate or cancel the provisions of any other state or local "lawsregulating construction or theperformance , : I am authorized to sign for and obtain this balding : pe mit. Date. 1 4. / 12--- Title: O.,oar re- ctv" This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT NO. CONTACTED R1 char A DATE READY DATE NOTIFIED 2nd NOTIFICATION .. _I 0 -#. QG BY: (init.b BY: (init.) PERMIT EXPIRES AMOUNT OWING .— � 3RD NOTIFICATION BY: ( init. ) PLAN CHECK NUMBER F INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) LOOk7 SQUARE OCC. SQUARE OCC. FET LOA �D BUILDING - nitial review FIRE O PLANNING O PUBLIC WORKS O OTHER 'BUILDING - final review PROJECT NAME SITE ADDRESS N J�, 9 gvAilett REVIEW COMPLETED INIT: INIT: e BUILDING( f ?ERMIT APPLICATION TRACKING INIT: INIT: YY1 US vm ok F\ i5h± SUITE NO. 9 Y io r t nk) vJ\j CMAR'iZ g CONSULTANT: (ROUTED DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. ZONING: INIT: - t - RV- Et IREME ,. Date Sent - REFERENCE FILE NOS.: MINIMUM SETBACKS: N- mAtt92, TYPE OF CONSTRUCTION: Date Approved - FIRE PROTECTION: Sprinklers Detectors ( N/A FIRE DEPT. LETTER DATED: 3f y.�rj`2_ INSPECTOR: 3 �. FAR/LAND USE CONDITIONS? Yes No S- E- UTILITY PERMITS REQUIRED? (l Yes p No AO PUBLIC WORKS Lt 1 I tR DATED: W- UBC EDITION (year): 19 86 08/17/90 SITE ADDRESS SUITE # 9404 East Marginal Way South, Seattle, WA 98101 VALUE OF CONSTRUCTION - $ 45,000.00 PROJECT NAME/T'ENANT Challenger Learning Center /Museum of Flight ASSESSOR ACCOUNT # 332404- 9019 -90 (commercial) U Demolition (building) 0 Other: TYPE OF 0 New Building U Addition LA Tenant Improvement WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) DESCRIBE WORK TO BE DONE: Addition of new walls, emergency exit doors and finishes at the existing storage area adjacent to the Great Gallery to accommodate the Challenger c BU IL i i' 1 o ice; ware ouse, etc.) Museum NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? ® No ❑ Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: 185,075 Tenant Space: Area of Construction: 1,694 SF WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? C No (] Yes IF YES, EXPLAIN: PROPERTY OWNER Museum of Flight Foundation (PHONE ( 206) 764 -5700 ADDRESS 9404 East Marginal Way South, Seattle, WA ZIP 98108 CONTRACTOR Cr -t„l �C �' PHONE ADDRESS t) 5 (.10c 1; ( ZIP WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT Gregov Architects PHONE (206) 622 -6990 ADDRESS 1218 Third Avenue, Suite:1200, Seattle, WA ZIP 98101 CiTY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER 139x9 00 EREBY CERTIFY:THAT I HAVE READ::AND EXAMINED. THIS 'APP.LICATION AND KNOW .T TRUE ANDrCORRE„T <'AND I A� `AUTHORIZED APPLY.`FOR THiS :P,.ERMfT'': BUILDING OWNER S FIATW RE) 1 .‘6 /CO, (4{ L. L. . - 1) ( ( / C3ei RINT NAME IC {� 7 µ f1 &/ OR AUTHORIZED AGENT ADDRESS c CONTACT PERSON BUILDIF' PERMIT APPLICATION BUILDING PERMIT. FEE PLAN CHECK FEE BUILDING SURCHARGE DESCRIPTION :AMOUNT RCPT # OTHER:':: DATE 1 Nlt4YC;(NAL o: At' So <<Tt1 DATE PHONE .764 , 5:7(1 CITY/ZIP PHONE E `Ifs / a? E >' APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. if you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES 03/10191 COMMERCIAL NEW COMMERCIAL BUILDINGS /ADDITIONS n Completed building permit application (one for each structure Assessor Account Number Two sets (2) of the following :.:: Specifications Structural calculations stamped by a Washington State license L_J Soils report stamped bye Washington State licensed engineer ; ... . r Topographical survey I Energy calculations stamped by a Washington State licensed engineer or architect Legal description. :. LI Workin g drawings stamped by a Washington State license architect, which include Site plan:.... Architectural drawings. Stnicturai drawings • Mechanical drawings • Elevations • Civil drawings • Landscape plan Completed utility permit application (one for entire project) Six (6) sets of civil drawings NOTE:; See utility permit application and checklist for specific utili submittal requirements. :. RACK STORAGE F-1 Completed building permit application Assessor. Account:Number. Two (2) sets of plans, which include Building floor plan showing.; • Entire space where racks will be located :,` • Exit doors Dimensions of all aisles .: Tenant space floor plan showing rack storage layout, aisles and RESIDENTIAL NEW SINGLE - FAMILY DWELLINGS /ADDITIONS.: 1 I Completed building permit application (one for each structure Legal description l J Assessor Account Number Two sets (2) of working drawings,: which: include; SUB ITTAL CHECKLIST . NOTE: include dimensions of.racks •(height "width and length), aisles and exit ways on plan. Structural calculations stamped by a.Washington State licensed engineer (rack storage 8' and over). . • Sao plan (Qn f.'an chowcin..est hydrantlocation. • Foundation plan inctuda access: to building, s howing ; ; •..Floor plan width and length of accass.) • Roof plan • Building elevations.(all:views • Building :cross- section Structural framing plans Washington State Energy Code da Completed utility permit application ri Six ( 6 ) sets of site plans showing utilities NOTE: Building site plan and utility site plan may be combined. See utility permit application and checklist for specific submittal requirements..: Additional topographical and soils information maybe required if unique : COMMERCIAL TENANT'IMPROVEMENTS Completed building permit tapplication (one' for each'structure or tenant): Assessor Account Number Two (2) sets of construction plans, which include :' Tenant'space plan with use,of each „room •fabell • Exit doors, egress; patterns New walls; existing. wall, and walls to, •be demolish Construction details Cross sections showing wall construction and method of attachment. for floor and;ceiling Structural calculations stamped;bya Washington State licensed engineer. may_ be. required.ifjtructural work is to be :done (2 sets) NOTE U anyutilitywark is to done; submit' separate utility permit REROOF ••.:: Completed building permit application Assessor. Account Number NOTE A oert ficationletter is •required prior to final Inspection andsigri off of the permit ANTENNA/SATELLITE :DISHES. Completed building permit application Assessor Account Number Two (2) sets:of working: drawings, which include RESIDENTIAL: REMODELS [1 Completed building permit application (one for each structure Assessor Account Number • Site plan Foundation plan.:. Floor :plan • l oaf , plan Building elevations (all views Building. cross •section Structural framing: plans NOTE If any utility; work Is to be done, provide; utility permit application and plans must be submitted; REROOFS'' LI Completed building permit appli one for each structure) n Assessor Account Number Narrative describing existing roof, material being removed, and material being installed: NOTE A certification letter:Is required prior to final Inspectronand sign.- ocation'.of.tenant space 'Existing and proposed parking • Landscape: plan .(if.applicable, t e ,:change o Overall building plan • • Tenant location • Use of adjacent (common wall) tenant Overall dimensions of building or square footage. ' Floor plan of proposed tenant space: one. for each structure Narrative describing existing roof, material being removed, an material being installed wo,.(2) Sets of plans; which include: Site Plan (showing building and location of antenna/satellite dis (— Details antenna/satellIte dish andmethod'of attachment: i Structural calculations. stamped by a Washington State •Iicense engineer.maybe required Project: Njoj.t C : ::: n: A Address: Special Instructions: D Date Wanted: r , i i —92— am.�n. Requester: C PhoneNo.: 7& '( -57foo 1 K .- Approved per applicable codes. INSPECTION RECORD C Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 - 137E" . "7""" - " .. _"_"""-".. ooGot PERMIT 4313670 0 Corrections required prior to approval. t: $30.00 REINSPECTION FEE REQUIRED., Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to 'schedule reinspection. ro ect: t t.551,.. m• r F r 1,1 r— ype o nspe on: ,- -- - --- Pct— , . ress: '� e a :.: Special Instructions: • -..,.. Date Wanted: 1 (40/92.- am p.m. Requester: r �� Phone No.: 76(1f 760 INSPECTION RECORD 0 Retalq a copy with permit P 10 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 6 0V0 I PERMIT NO. (206) 431 -3670 • ❑ Approved per applicable codes. /E Corrections required prio to approval. COMMENTS: . t) esti ryksT.A. u ss y CGS to r ., C hi ', lg c^v./Wi -'11 ' ..lt/i e1D Pc?1....... ❑ paw REINSPECTION FEE REQUIRED: Prior to reinspection, fee mu §t be paid at 6300 Southcenter Blvd.,•Suite 100. Call to schedule reinspection. Receipt No.: Date: 9 INSPECTION RECORD 0 Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS; ' 4Z1 ■140 IS • Al /R.44vim t-rw W 1 l - WI ► (fir++ r ►J G A,4)0 6.wa. Z LO( ER IT (206) 431 -3670 ❑ Corrections required prior to approval. S uSP Nso - D eel trt %JC, G ti t, S A P ila,4 W-io. O $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, tee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 472 NEMONI Sp: gal nstruct ons; 61 I.O �`t a ei; g". Date anted: (9_ 9 .... - () p.m, Reque,�j�r / �J (� �it /1/D C �7 ,l�h Phone o.: watt , . S / 60 INSPECTION RECORD 0 Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS; ' 4Z1 ■140 IS • Al /R.44vim t-rw W 1 l - WI ► (fir++ r ►J G A,4)0 6.wa. Z LO( ER IT (206) 431 -3670 ❑ Corrections required prior to approval. S uSP Nso - D eel trt %JC, G ti t, S A P ila,4 W-io. O $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, tee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. rotec: g 4 A•• Tess. 67 1, a i / � i . �� ` a � S UM = 0 nspecton: ' ` ' • a e•: -"---4- Date 'anted: S . 2 ;GGkk. , �G am, n 4 Special Instructions: -4- ester; IJ APLI/ ll//�� Phon Phone No.: r .- U/ INSPECTION RECORD Retain a copy with permit INSPE CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT No. (206) 431 -3B/0 O A pproved per applicable codes. COMMENTS: Inspector: Receipt No,: O Corrections required prior to approval. c.a- tri,,r ittcotldr Date: o $30.00 REINSPECTION FEE REQUIRE Prior, to reinspection, tee must be paid at 6300 Southcenter Blvd., Suite 100;; Call to schedule reinspection. Date: 5 ° -C . roe : i _:.. ! "11707 ..::. 7107 a ion; . / . e s.' : , %ifi ` .. re •.te • lea: gal Instru i ons: - ' Date /�f 2---- am. ?( .m. ` R u Plano No.: 7 _, 5'70-6 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT Ny (206) 431 -3670 z te Approved per applicable codes. COMMENTS: ❑ Corrections required prior to approval. Date: t 2 5 Inspector: ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule 'reinspection. Receipt No.: Date: 77Olect: A 4-- FL. ype o nspect on Address. " / qq10 1 lAd Date Calle d: . 7.-' Special Instructions: ____ Date Wanted: ,..--_- , f -2-f2., 4 1Z. ant Requester: A-11,1A/A, Phone No.:1 ( 4 . , .. 7(5 . () I • J ' , • NPCTION RtdanD'' Retain a copy with permit, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 k Approved per applicable codes. PER 206) 431-3670 Ci Corrections required prior to approval. / 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee mat be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Gary L. VanDusen, Mayor TUJKWILA FIRE DEPARTMENT /3 . mc..,6 1/7 FINAL APPROVAL FORM r„' 9 006/ Control No. Permit No. Project Name i4 5E' &'vv■ Address I` /(it(' . 15f /14 / jeti! /f.7 r Suite # Retain rrenti. inspection; schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Total Fees:: Total All Payments: Balance: 634.80 634.80 .00 ** * * * ** * ***k **kk ** ** * * ****Jr *k *J** * fi e * * *A** *** *k* *r* CITY OF TUKW1LA WA TRANSMIT **** * * * * * * * * *. * * ** ** * * * * * * * * * * * * * ** TRANSMIT..,.Number�: 9200.0131 Amo .386.50 03/12/92 14:21 Perin t No: 092 -0061 ,Type: 8-BUILD HUILDINO PCft4IT Parcel .Na: 3.32404 -9019 .Oite.Ad.dress:: 940,4 CAST MARGINAL WY 8 03/12/92 P tyment'. Method: ;CHECK Notation:, MUSEUM OF F'.L3.t HT In i t•. .OLD ***.******* k**** * * * * * * *** * **k * *** *, * * *.**. *. *** *brit * * * *. *' * ***** * ** *fi Account Cade Description Paid 000/322 100. BUILDING - NONREB. 382.00 QU0 BU /386'.904 STATE ILDING. SURCHARGE 4.59 Total '(This Pay.ment): 386.50 .. GENERA 382.00 GENERA 4.50 TOTAL 386.50 CHECK 386.50 CHANGE 0.00 7897A000 14 :19 '********************************* *k * ** * ** ** ** * * * * * * * * ** *k * * *k * ** `C7 TY. or TUKWILA, WA TRANSMIT ****+ F*** k �k****** ******* ***** * * ** ******,4 * * * * * TRANSMIT Numbei^:.:92000127•Amouritis 248.30 02/25/92 :L4:.30" Permit No: 092- -00Ci, .:" Type: 13- BUILD., .BUILDING PER 1 5/92 Parcel No.: :332404-9019: Site Ad dreaa: 9404 EAST' MARGINAL WY S Payment Method: ,CHECK Notation: ,MUSEUM CF FLIGHT Iriiis.SLU ,4** * ** *.*4 *A.* 1 * *fi * * ** * * * * ** Iii** * ** r *Ar;k* * * * ** * * * 4*ki4** ** *fit * *4, *4 k Account ',code pescr i pt i on 'Paid'' '000/345i.830 . PLAN CHECK -. NONRES 2413.30 Total (This Payment): 248.30 GENERA 248.30 TOTAL 248.30 CHECK 248.30 CHANGE 0.00 7298A000 3.4 :28 Total Fees A l l Payments; Balancer. 634.80; 248.30 386.50 Address: Tenant: Type : Parcel #: ******* A*********** *• k• k***** * ** * * *** ** * ** ** *•k*** * *** * *** ** * *•k * * *•k * * ** * * *•k Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect and the 'Tukwila Building Division. 2. Electrical permit? shall be q,btained through the Washington State Division of Labo,r�� and In;dUst 'ies, electrical work .wi 1 1 be inspected ,;by that agency be• under separate permit through . All mechanical J' r r. . �,, a?t ',4 r 'A �a the City of T 'la v , � n : t; a 4r ' , , 4. All permits; :'n ec �` p i e'dor ds,n.andl ppr ao' ed sn °s�I shal 1 be r �� � � r• '� �. .; �pla ° - Sri' *�; maintains ' avai la�ble a the job site prio. tAo the stirs of any constr 'uc'ti op, . 11,,These..doccumentc . ar'e etc) be maintained }� 'availab�ld'until Sf� nal ��inspection approval'°is granted h 5. Any new„� 1;i grid .l i il t' 0 y � f �,i�.ure insta'1Flat orb, is r g , q s i sly, requi k d',f to meet ,,,...1 ,a'teral y wr,.�a in re,,uirements f <or s". o mic •t � y , c, 6. Any x�pos d i nsulation ; 3 backi , g..m'ateria1 shall have a Flame Spreeac Rat of 25 ors less, t kand"'•ma.teria1 shall bear ' ''ti f i c roi ori show inig the f i r•e -pe'r kormanoe rating thereof f r., 7 Allr to b°e' do. a in` co fo,rlii ce...,�uith appr.ove''d p ,s and requirements`" \tii � ',fori r Building Code 4198 {8 �y' Ed Ion), nifo.r�ma�.M 1 Code,'(1988' r i..l Edition)) Washington Ste Energy Code (y19.91 Edi pion) , 'bland Wa's'hi•ngton State ",M Reg at 1 orris for `Barri�.e cf e ,e ' c il to'-d§90) Edit ion). :1.' .Ln,.WW: 8. V a Oil %: Perm i t ,� ,T h s u art'•c e `- o ff•aLa ,... p e m i t or app o v a..la pl s i t" , speaifl; cat1oi�s«,, an 1 ,dt- ° compUt�at<lo'ns;,,�s�ja�11 not be o '� o` ' strue to b a permit for,. or • app, oval -'of,�i,any violation Of ' 4 ' o'f tJ e F e, ,, e dry, K 1 provisions of this' cod'etior :o,� an other �.� ord i' nce. cth 1ty if ay jurisdiction. pe'r^�m t pre" mi g ;t r autho ' kf, ' violate or cancel t i e provisions of � ithis code shall valid. 0 #M. 1 i 9404 EAST MARGINAL WY S. MUSEUM OF FLIGHT B -BUILD 332404 -9019 CITY OF TUKWILA Permit No: Status: Applied: Issued: • B92 -0061 ISSUED 02/25/1992 03/12/1992 DATE 111 � I 1 111 Z' ! . + I PROJECT NAME plus us eu vh o1 F I g I�1T e k ade,„ xp' 1 �� ADDRESS 1 4d 4 G . nit (.-f ,S crtth- CONTACT PERSON 2\ Ju? si - . PHONE �6 4 S 7-0 0 ARCHITECT OR ENGINEER Lid • - c c e v , ,I I PLAN CHECK/PERMIT NUMBER G l 2 - o a 61 TYPE OF REVISION: ak, e o-F wz.t 1 +'.& o ro 6 54-) 1( 1 ha„ v w4( rz . nn 1; i tAs -C ree - s 4 e �; P 2,4-12-1-1 It Wt,� s t v∎ RECEIVED � 4� MAY 1 9 199. SHEET NUMBER(S) 4. 2.. 4' "Cloud" or highlight all areas of revisions and date revisions. * * REVISE CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 N SUB 1TTAL * City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review Control #B92 -0061 (512) Dear Sir: March 4, 1992 Re: Museum of Flight - 9404 East Marginal Way South John W. Rants, Mayor The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the, following concerns: 1. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 12.106(c)) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 12.106 - 12.111) Exits shall be illuminated any time the building is occupied with light having an intensity of not less than 1 foot candle at floor level. Fixtures required for exit illumination shall be supplied from separate sources of power for Group I, Divisions 1.1 and 1.2 occupancies and for all other occupancies where the exiting system serves an occupant load of 100 or more. (UBC 3313 (a)(b)) 2. All new sprinkler systems and all modifications to sprinkler systems involving more than 25 heads shall have the written approval of the Washington Survey and Rating Bureau, Factory Mutual, Industrial Risk Insurers, Kemper, or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to The Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1528) Sprinkler protection shall 'be extended to all areas iMINII■MIMIISMINIMMIMEN•11•111•10MMI■If City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 2 John W. Rants, Mayor where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13- 4 -1.1, 4- 4.1.7.1.1, 4- 4.1.7.5, 4- 4.1.7.6.1) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) 3. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72E, 2 -7.4) (UFC 10.501(a)) Call the Tukwila Fire Department at 575 -4404 for approval of any system shut down. Have job site address, name, and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1528) 4. All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) All interior wall covering materials shall be fire- resistive or shall be treated to be fire- resistive, so as to result in a flame- spread rating as required by UFC Appendix VI -C tables 42A and 428. A certificate of the flame spread rating is required to be delivered to the Tukwila Fire Department. (UBC 4204) (UFC 10.401) This review limited to speculative tenant space .only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. -� �.�� Permit No: B92-0061 Type B -BUILD Location: Parcel #: 332404 -9019 Address: 9404 EAST MARGINAL WY S CITY TUKWILA COMMENTS ACOM Status: PENDING Applied: 02 /25/1992 Issued: ******************************************** * * * * * * * * * * * * * * * * * * * * * * * ** * * * * ** Permit Comments: EXITING MEETS REQMTS OF CHAPTER 33. O.K. L the historic Red Barn, the first home of The Boeing Company, learn about the men and women who pioneered a new industry as you relive flight's greatest trials and triumphs up to the brink of World War II. In the Red Barn, exhibits include a beautifidly restored 1917 curtissJemly biplane, an authentic recreation clan early aircraft manufactur- ing wood shop, and a working replica of the wind tunnel used by the Wright Brothers. Become a Museum of Flight member. Receive unlimited free admission, bimonthly issues of Flightplans and Museum of Flight News, a 15% discount on Museum Store purchases, early notice of special events, and more. Please ask our staff about membership, or call (206) 764 -5711. The Museum Store features a broad array of flight - related merchandise and collectibles for all ages. You'll find a wide selection of unusual gifts, books, clothing, models, posters and more. The Museum of Flight Restoration Facility at Paine Field in Everett, Washington is open for tours Tuesday- Saturday from 10:00 a.m. to 5:00 p.m. Please call (206) 745 -5150 for information and driving directions. Admission ADULTS (ages 16 & over) $5.00 YOUTTIS (ages 6 -15) $3.00 CHILDREN (under 6) FREE MUSEUM MEMBERS FREE GROUPS (10 people or more) $4.00 General Information Open daily 10:00 a.m. to 5:00 p.m., Thursday to 9:00 p.m. (Closed December 25.) Fully handicapped accessible Ample free parking. Group, school and special interest tot for parties of 10 or more may he arranged by calling (20( 764 -5700. Visitor Information: (206) 764- 5720. MUSEUM OF FLIC 9101 East Marginal Way S Seattle, WA 98108 -109' Driving Directions: From Interstate 5 (North or South), take Exit #158, turn tight at East Marginal Way South, and drive approximately 3/4 of a mile to the Muset complex on your right. Parking is available on the airfiek fek (east) side of the building. Bus Directions: Front either Sea -'I'ac Airport or Second Avenue in downtown Seattle, take Metro Bus #17 Metro information: 447 -4800. Information and merchandise also avdlable at the Museum of Flight Store at Westlake Center in downtown Seattle. During the school year, The Hangar may be unavailable weekda ?s until 1:30 p.m. to accommodate student groups. © Museum of Flight and Red Ham are registered trademarks of the Muse of Flight Foundation. Accredited by the American Association of Mustn't': Member National Tour Association. Admission ADUI:Is (ages 16 & over) $5.00 YOU'I'IIS (ages 6 -15) $3.00 CHILDREN (under 6) FREE MUSEUM MEMBERS FREE GROUPS (10 people or more) $4.00 C General Information Open daily 10:0( a.m. to 5:00 p.m., Thursday to 9:00 p.m. (Closed December 25.) Fully hauulicapped accessible. Ample free parking. Group, school ,rid special interest tours for parties of 10 or more may he arranged by calling (206) 764 -5700. Visitor Information: (206) 764 -5720. MUSEUM OF FLIGHT 9.1IlI I i t Marginal Way Smith Seattle, WA 981014.109 Driving Directions: From Interstate 5 (North or South), glee Exit #158, turn tight at East Marginal Way South, and drive approximately 3/4 of a mile to the Museum complex on your tight. Parking is available on the airfield (rust) side of the building. Bus Directions: From either Scat -'I'ac Airport or Second Avenue in downtown Seattle, take Metro Bus #174. Metro information: 447 -4800. Information lull( merchandise also mailable at the Museum of Flight Store at Westlake (enter in downtown Seattle. During the school year, The Ilangar may be unasailablc weekdays until 1:30 p.m. to accommodate student groups. 1) Museum of Flight Ind Red (tarn are registered tr of the Museum of Flight foundation. Accredited by the American Association of Muse Member National Tour Asxreiation. c W lcome to the Museum of Flight, Seattle's most spectacular attraction! Conveniently located 10 minutes from downtown Seattle and Sea -Tac International Airport, the Museum of Flight is unlike any museum you've ever seen... In the steel - and -glass Great Gallery, the history of aviation soars past. A vintage DC -3 is suspended six - stories above you, flying in formation with over 20 other full -size aircraft — from biplanes to sea- planes to supersonic jets... and on to outer space. Climb into the cockpit oft, full -scale mockup ofallorthrop %A -18, then design your own tactical fighter using your imagination and the latest In computer technology. The Museum's location on one of the country's busiest airfields invites a wide range of special events. Year- round, you'll find visiting aircraft, theme weekends and lively educational programs offering an informative and enter- taining look at the world of flight and the people who make it possible. S the ground, walk under the wings of a 1929 Bc 80 -A "Pullman of the Air "...Set your sights on a Blue A A -4 jet...Picture yourself on a moon voyage in our new Apollo exhibit And get ready to meet the Blackbird! The museum's prized Apollo Command Module (at right) is the centerpiece of a dynamic new exhibit opening in early 1992 on the history of manned space exploration. Through a wide range of interactive educ tional programs, you'll learn about the individuals, eve and technology that took us to the Moon...and beyond Drop in at The Hangar, award- winnit exhibit foriv, people. Try of authentic fligi climb into oln three aircraft, take off with I most Imagina educational programs offe anywhere. Watch for.... New exhibits, including the FG -ID G the A -12 Blackbird, and the return of the restored B -1' Flying Fortress...New educational programs, including Northwest's first Challenger Learning Center...and a wi range of exciting events and fly -ins. • . •••,( iv' `•• 1 111k1OPP "; +4 '• • , , -•• : 'T ta.441meiVo 1:•"-***',„ .r_ , „;ig • •.:"- • * • P. 1 I 4 G t: n • A/1W, J.1.11• 111111.4", , 0 n the ground, walk under the wings of a 1929 Boeing 80-A "Pullman of the Mr"...Set your sights on a Blue Angels A-4 jet...Picture yourself on a moon voyage in our new Apollo exhibit And get ready to meet the Blackbird! The museum's prized Apollo Command Module (at right) is the centerpiece of a dymunic new exhibit opening in curly 1992 on the histoty of manned space exploration. Through a wide range of interactive educa- tional programs, you'll learn about the indhiduals, events and technology that took us to the Moon...and beyond. Drop in al The Hangar, our amid-winning exhibit ihr young people. any on aulbenticflight gear, climb into one of three aircraft, and take off with the most imaginative educational programs qffered anywhetv. Watch fir—. New exhibits, including the FG-1D Corsair, the A-12 Blackbird, and the return of the restored B-17F Hying Fortress...New educational progruns, including the Northwest's first Challenger Learning Center...and a wide range of exciting events and fly-ins. �� W s .e w.urrr �.. • CHALLENGER LEARNING CENTER SIMULATO S`TARATE r `,MIT AND PROVAL t,LQUIRED 1. PROJECT NAME: MUSEUM OF FLIGHT, 9404 East Marginal Way S. , Seattle Assessor Account Number: 332.404 -9019 -90 2. SCOPE OF WORK: The Challenger Learning Center Simulator Project includes addition of new walls, emergency exit doors and finishes at the existing storage area adjacent to the Great Gallery to accommodate the Space Station and Mission Control Room. This project also includes additional mechanical and electrical work. 3. OWNER: Museum of Flight Foundation 9404 East Marginal Way South Seattle, WA 98108 Telephone: (206) 764 -5700 Fax: (206) 764 -5707 Richard Beckerman Project Director Ken Blanchard Exhibit Coordinator ARCHITECTS Gregov Architects 1218 Third Avenue #1200 Seattle, WA 98101 Telephone: (206) 622 -6990 Fax: (206) 343 -5595 Lidija Gregov Principal DRAWING LIST A - COVER SHEET / GENERAL NOTES ARCHITECTURAL A - OVERALL PLAN / NEW EXHIBIT LOCATION A - FLOOR & CEILING PLAN / WALL TYPES A - SECTION / ELEVATIONS SEPARATE PERMIT AND MECHANICAL t,PPROVAL REQUIRED M -1 MECHANICAL PLAN ELECTRICAL E - HVAC PLAN 4. EXISTING SITE AREA: 226,565 SF 5. EXISTING ZONING: M - H HEAVY MANUFACTURING 6. SEISMIC ZONE: ZONE 3 7. FIRE ZONE: ZONE 3 8. USE OF EXISTING BUILDING: MUSEUM 9. OCCUPANCY: GROUP A, DIVISION 2.1 (3) 10. TYPE OF CONSTRUCTION: TYPE II, 1 HOUR 11. EXISTING BUILDINGS: 185,075 SF 12. CHALLENGER LEARNING CENTER EXHIBIT AREA: 1,694 SF 13. EXHIBIT AREA AND USE BREAKDOWN Mission. Control One (1) Exit Required Space Station Technical Access Total One (1) Exit Required 14. EXIST. FIRE EXTINGUISHING SYSTEM Automatic Spr :nkler System Automatic Fire Detection System 735 -x' 1/15 = 49 Occupants 510 x 1/15 = 34 449 1/100 = 5 = 39 Occupants 1 I ' I ' l'I '1 (Illlillll IIIIIIIII IIII�IIII IL{III{I iIIIIIIIIIIIIIIIII� n IIII Iillillll L IIII�IIii IIII�IIII Viii ii; Viii lllllilli�ll illlll I IIIIIIII LEGEND A5.2 BOT. OF FTG. EL. 372' -0' uuuuu nu nnn a. b. c. SECTION NO. SHEET NO. GRID LINE NO. DETAIL NO. SHEET NO. ELVATION NO. SHEET NO. POINT ELEVATION WALL TYPE NORTH ARROW EARTH ACOUSTIC TILE GENERAL NOTES 1. All work shall comply with applicable codes and ordinances. 2. Verify all dimensions and existing conditions on the job before proceeding with the work. Discrepancies, if any, are to be referred to the Architect for settlement. 3. Where existing work is damaged, cut or defaced due to performance of new work, the Contractor is to patch and repair same to match adjoining surfaces. Repair finishes shall be extended to the nearest visual break lines such as corners, ceiling lines, top of base and similar. 4. Where items are noted on plans to be removed, it shall mean the complete removal of the work indicated and the associated patching and repairing to match adjoining work. 5. See mechanical and electrical drawings for additional notes and symbols. 6. The Contractor is responsible for the review of the mechanical and electrical drawings for cutting and patching work within the building, beyond the limits of the architectural drawings. 7. The Contractor shall verify all rough -in dimension requirements for equipment furnished and installed by himself or others. 8. All contractor installed items shall be supplied with required mechanical and electrical services to provide operation of items installed. Provide required mechanical and electrical services for items installed by others. 9. All recesses located within fire rated partitions shall be constructed to maintain required fire rating of the partition. 1 0. In general, the plan dimensions shown are as follows: To centerline of metal studs To the face of exterior finishes To the face of concrete 11. At metal stud partitions, studs are to extend from floor to underside of the structure above, unless otherwise noted. 12. Provide closure, meeting the requirements of governing fire authorities, between all fire rated floors, shafts and building partitions and any penetrating ducts, pipes, conduit, mechanical, electrical and other items. 13. All wood blocking shall be fire retardant. 14. Wood in contact with concrete or masonry shall have a preservative treatment. 15. All ceiling suspension systems shall have seismic restraints per local building codes and ordinances. CONCRETE E= METAL (CMU) MASONRY UNIT PLYWOOD WOOD (FINISHED) WOOD (ROUGH) INSULATION (LOOSE OR BATT) INSULATION IMES RIGID GYPSUM WALL BOARD PLASTER, SAND, CEMENT, GROUT FILE C O' I understand that Ma Plan : hr,:k approvals are aibfeet to errors and orris;;: plans does rcK afi :I, a the a�+,..:,__,! : or any ,c +i' : r n,;!;r,: .t copy . of contractor's `8-44 ., Date ...?l�z /��'_ Permit No -oproval of -- (�i ✓. `•fO4s: .... 1.Q - 00 0..1 ..... RECEIVED CITY OF TUKWItA FEB 2 5 1992 PERMIT CENTER GREGOV ARCHITECTS 1214 TWO AVE., SUITE 1200 St AME. WA 98101 208/522 -4090 CHALLENGER LEARNING CENTER SEAMS, WASHINGTON APPROVED FOR BID BY THE MUSEUM OF WONT DATE BY CITY OF TUKWILA APPROVED MA 9 'y ::: w� 4 • - 81 !I- NG DIVISION NO - HDATE DRAWN BY CHECKED BY DATE JOB NO. DRAWING SCALE SHEET LG 92 -122 REVISIONS FEBRUARY 25, 92 COVER SHEET / GENERAL NOTES A -0 `011111111 '11111HU .11111111] i Homy paiimk -- SIDE GALLERIES EL. 20.00 MAIN GALLERY EL 14.50 MAIN GALLERY EL 9.00 CHALENGER LEARNING CENTER SIMULATOR SEE SHEET A2 FOR DET. PLAN MAIN GALLERY EL. 20.00 ................ 11 it, et 11 II I 11 11 It I1 II 4% II 11 ll MI 1! • II III 11 1I 11 11 II u p II 11 11 1 i1 NI 1 II II 71 11 II 11 11 11 iI 11 11 S! 41 % X11 11 II 1 . 1l 11 11 II 1I II /1 :1 .11 II 11 11 ■ LI ■ I I 1 I 11 1 ■ , 1 1 11 11 1 ■1 11 11 x 11 1I 11 1 !1 1 11 A 111 R 11 1I '11 !I it II I1 II 11 II II 1I MI IN II 111 $ 1I 11 it 11 II 11 fli SI II 11 I 11 11 1 I .�11 I� 1 i u1,11,1 \ \\`� •111111 I:1mm FIRST FLOOR BASEMENT MAIN GALLERY I!f'�'{'I•I I'll'I'�'I, I'!'�'� ��� I'I'I'�'1 � ������ �'I I � I'�� � I'! g lI .0 i I i EL i TC i l i L ;11411111611111 0 • • CORR. 3 Wir 'VD WI 10 `11111 11U11 MISSION CONTROL STORAG — SPACE STATION o 0 PLENUM O rJ" Lays • • • Eel 0 MECHANICAL 0 • M I . r I■ NM MI UM � U LI 0 CHALENGER LEARNING CENTER SIMULATOR SEE SHEET A2 FOR DET. PLAN No. t8 ,cg""e,."'."".'.. STORAGE EL. 9.00 — CHALLENGER LEARNING CENTER SEE SHEET A2 FOR DET. PI 1N CORR. 0 0 0 /// RECEIVED CITY OF TI IKWIIA FEB 2 5 1992 PERMIT CENTER • GREGOV ARCHITECTS 1218 THIRD AVE., SUITE 1200 SEATTLE. WA 98101 206/622 -6990 CHALLENGER LEARNING CENTER SEATTLE, WASHINGTON APPROVED FOR BID BY THE MUSEUM OF FLIGHT DATE BY CITY OF TUKWILA APPROVED MA ,) t c B! It D! D VISION NO. DATE DRAWN BY CHECKED BY DATE JOB NO. DRAWING OVERALL PLAN & NEW EXHIBIT LOCATION SCALE SHEET LG /TS 92 -122 REVISIONS FEBRUARY 25, 92 11111■7■111.1dMONO• Mel 1/16" 1' -0" A -1 (A) EXIST. STORAGE 1--w N w 4 ,11s LAJ ¢/- CD w � 0 (n 0w a ® NEW 3' -6" DOOR WITH PANIC HARDWARE FLOOR 1 SCALE : 1/4" = 1'- 0" 3' -10" 2' - -0 "J, 2' -0 " 3' -10" MIN 1 EXIST. COLUMN PLAN 7' -3" 1" ACOUST1CAL PAN ,EXIT, I CEILING PLAN SCALE : 1/4" = TAO 17 71► : ug i`ri no,v -" ri4ii .. entta ver 1 I I of ;i I I D 1 it ' i i 1 O `2) DEMO EXIST. WALL FOR NEW WALL j AND 'WINDOW PROVIDE BASE Pi PAINT EXIST. STORAGE SIDE A3 MISSION CONTROL I NEW CARPET TILES ON EXIST. CONC. SLAB 22' -3" NEW WALL MISSION CONTROL EL. 9' -C" r tO A3 GREAT GALLERY EL. 9' -O" RADIUS 42' - 0" 9' -3" I - ' F E J Il ll 11 11 II I EXIST. CONCRETE 11 WAFFLE SLAB r - NOM 3' -0 "X 3' -0" I I PAINT -- . 1 1 CETLING GRID ENTER OF OW L _._J r - _ - -I -- -1Ir- I II II ---1 -r I I I L__J - ___IL _ III I I I I , II II II L✓_ JIL__ L __J J L_ - --� • - --I iI MEM II EL 17 -1" (8' -1" FROM FLOOR) I , ��.�7,�,s1r4."mrmtr.. w7■e=m�•..rTw.w►.wta..�►Rw�.�s A ,:mamtrioni ► .�r.�r..w= l `1 4' -•O" IY 0 2' -0" 2'- 7 -3 59' -0" A3 J TECHNICAL ACCESS (4) EXIST. CON¢. FLOM EXIST. COLUMN FRY REGLET ALUMINIUM MOULDING TYP. BAKED -ON COLOR FINI EXIS"ING SPRI VKLER TYP. 3H 1 1/2 HOUR FIRE RETARDANT . UL APPROVED REVOLVING NEW TILE FLOOR OVER DARKROOM DOOR EXIST. CONCRETE FLOOR 1212 -BLACK CUSHION TILES (1X1) TURTE PLASTIC OF CLEVELAND SPACE STATION 22' -3" CEILING LINE ABOVE N.I. C - ----ll SPACE STATION EL. 9' -0" EXISTING DOOR I NO c) NEW WALL ONE HOUR- - - fil Ei i TT I: V 6 'In (V A3 EXTEND NEW WALL TO CONC. CEILING WALL TYPE SIM. TO W/ 18 GA STUDS FRAME FROM STEEL TUBE 1 4x4x1/4" FOR SUPPORT J 0 0 N L.0 a 0 Z 0 o °a 4 I 1 NEW 3' -0' DOOR FIRE RATED 20 MIN. WITH PANIC HARDWARE/ PREFINISHED METAL GRID McDULAR SYSTEM TO ACCOMMODATE 'X4' LAY -IN TILES WITH 1 -1/2" SQUA E OPENINGS (SCIENTIFIC LIGHTING PRODUCT - OF OF MARYLAND) STORAGE SIDE PAINT < 1 51/4" <1 a> DO NOT ADD BATT INSULATION co 1 5 1/2 "I ALU' 4U c(ouL.pWC T'( EKE ► - ��Ot F. (U \ 518" TYPE X GWB 4 SOUND CONTROL BATT INSULATION 4" 20GA METAL STUDS ® 16" O.C. 5/8" TYPE X GWB SOUND RATING STC 49 ONE (1) HOUR WALL WALL TYPES (2) 1/2" PROPRIETARY TYPE X GWB BATT INSULATION 3 1/2" 20GA METAL STUD CO 16" O.C. (2) 1/2" PROPRIETARY TYPE X GWB SOUND RATING STC 45 -49 ONE HOUR WALL ASSEMBLY, GA FILE WP 1125 1) SECTION NOTES FOR ALL SOUND RETARDANT PARTITIONS 1. WHEREVER CAULKING IS CALLED FOR, USE A SILICONE -BASE NON - HARDENING COMPOUND 2. ALL PARTITIONS HAVING ACOUSTICAL INSULATION MUST BE SEALED, TOP, SIDES AND BASE WITH CAULKING WHERE PARTITION SEALS TO A ROUGH, TEXTURED OR CORRUGATED SURFACE, SPECIAL CLOSURE STRIPS MAY BE REQUIRED IN ADDITION TO CAULKING 3. OUTLET BOXES MUST BE CAULKED ALL AROUND. HO:.ES iN BOXES MUST ALSO BE CAULKED 4. PEI,ETRATIONS OF SOUND RETARDANT PARTITIONS (DUCTWORK, CONDUIT OR PLUMBING) MUST BE SEALED ACOUSTICAL SEALANT TOP OF WALT. ACOUSTICAL SEALANT 0 FLOOR (SIDE SIMILAR) 0 N 1 1 I 1 1 1 N 4 7/8" 1 I i PL. LAh. 1/8" PLASTER VENEER 5/8" TYP. X VENEER PLASTER BASE 3 1/2" 18GA METAL STUDS 0 16" O.0 5/8" TYPE X GWB Q. 4 - I; i DP rAcE d i/ 1A-M. 5 X5 rL„ SASE' yz NET: STUDS a� V" O.C. _W-f &iv 1 R --- 110K) ITOS IJ. I . C APluSTA3Lir S 4E L-U I to_, 4n f'Ly W OOt7 v(/fl CA$IIJEY I.IUEr_ 'rye RCK SgAC -KET': AV-- 4 VoC,T. NO. S7 l.E r�CTtl 7 16/11 CN1v ' Htil_ `- �TA►J[a4t�t7� : k�.j- voC�t No. 51 APPROVED FOR BID BY THE MUSEUM OF FLIGHT DATE BY DATE SCALE maw 1 HEET ' = 1 _ 011 C m of TUKW NIA's 9\9L pe BMIT CENTp GREGOV ARCHITECTS 1218 THIRD AVE., SUITE 1200 SEATTLE, WA 98101 206/522-6990 SEATTLE. WASHINGTON fA1 CIIY or TUK4ILr1 , ' APPROvED MAY ; 190 DRAWN EiY I.G/T'3 CHECKED BY LG JOB NO. r 92 -122 AS NOTED CHALLENGER LEARNING CENTER RIIDIN, IVI • Ya ;) � Z� APRIL 1, 1992 DRAW OOR PLAN / C EILING PLAN A -2 SIM EXIST. RAIL REPAINT EXIST. WALL - CA SECTION CD 1/4'= 1'- O" GALLERY NORTH EXIST. 2 1/2" CONC. TOPPING SLAB EXIST. 6" SLAB ON GRADE .. -�--. EXIST. F.E. INSULATED LAM. GLASS c? LAMINATED GLASS TYP. SI PLASTIC LAM. 3 EAST 1 / 11- 0 MISSION CONTROL (4) MONITORS N.I.0 i" 2 Cc. rit / I /2 f.' (��i. Li,/ r� (4) CLOCKS N.I.0 LAMINATED GLASS TYP. 0 F- l-1 I a / 31-"Z G / /4+-t f 6'! L : ie CORRIDOR WEST 1/4-. 1'- 0" 4 CEMENT FILL METAL FRAME FOR FIRF RATED OPENING NEW DOOR SIM NEW OPENING REPAINT EXIST. WALL 7 ST. LL E ITIT Lir I! 1 1 1'1 1,1 I TI' I EI i iI I r6 IIII�IIII IIII,III IIIIIIIII IIII lIII IiIIIII!I III!IIIII FIN. FLOOR EL. 20' -0" BASEMEN EL. 31 4i 5 6I N0.18 g,<.. rf IIIIIIililill iillllill IiIIIIIII lilllllll l i:.I Ilil illll!lII ililllili iIIIIIIII EXIST. WALL n JAMB 1 1/2' r-0" Nitli IP .41111111111111V/1401111101111110 4111 CO WEST 1/4'= 3/4" 1 3/4 GWB. PAINT ACOUSTICAL PANELS PAINT RUBBER BASE TYP. I 24" METAL DOOR HARDWARE STORAGE DOOR 1/4-= 1 OR ONE SGL. DR. 3 MISSION CONTROL FR STORAGE 2' -0 X6' -8 "X1 3/4" W X W 1 1/2 PR BUTTS 179 US26D 4 1/2 X 4 1/2 1 EA LOCKSET 765L4 -L9555 US26D X CLS X WBX RHR 1 EA WALL STOP WC9X US26D 3 EA SILENCERS 65 RHR 90 DATE BY NO. DRAWN BY DATE JOB NO. DRAWING SCALE SHEET 'aC 0 GREGOV ARCHITECTS 1218 THIRD AVE., SUITE 1200 SEATTLE, WA 98101 206/622 -6990 CHALLENGER LEARNING CENTER SEATTLE, WASHINGTON A RPP OVED FOR BID BY THE MUSEUM OF FLIGHT CHECKED BY LG/TS 92 -122 APRIL 1, 1992 SECTION ION & ELEVATIONS 1/4" 1'- 0" A -3 GWB PAINT TYP. EXIST. 2 1/2" CONC. TOPPING SLAB NEW 1 HOUR N STRUCTURE - ON EXIST. CONC WAFFLE SLAB T----a.M.I-11 RI .. • .. 1 1111, Mall. : \ /.,„--- ------...N\ SUSPENDED CEILING N - GWB. PAINT rip. N EXIST. 7 -�,�, t gill ' . /i + .4 __� ° 0 Z. L _t L ( -fi - -- OVERHEAD WALL CONNECTION NEW .___.. . - ACOUSTICAL \_ L PA WALL EXIST. -- / \ ` -. MISSION CONTROL --- � WALL COLUMN GWB PAINT TYP. ;; SPACE STATION 1 / ./ -- _- y ..A. __ _---- -._ -__ - _ -_ -.._ _ - ___.___._.._.._ -. A" 0110000 b AQr IVY) SIM EXIST. RAIL REPAINT EXIST. WALL - CA SECTION CD 1/4'= 1'- O" GALLERY NORTH EXIST. 2 1/2" CONC. TOPPING SLAB EXIST. 6" SLAB ON GRADE .. -�--. EXIST. F.E. INSULATED LAM. GLASS c? LAMINATED GLASS TYP. SI PLASTIC LAM. 3 EAST 1 / 11- 0 MISSION CONTROL (4) MONITORS N.I.0 i" 2 Cc. rit / I /2 f.' (��i. Li,/ r� (4) CLOCKS N.I.0 LAMINATED GLASS TYP. 0 F- l-1 I a / 31-"Z G / /4+-t f 6'! L : ie CORRIDOR WEST 1/4-. 1'- 0" 4 CEMENT FILL METAL FRAME FOR FIRF RATED OPENING NEW DOOR SIM NEW OPENING REPAINT EXIST. WALL 7 ST. LL E ITIT Lir I! 1 1 1'1 1,1 I TI' I EI i iI I r6 IIII�IIII IIII,III IIIIIIIII IIII lIII IiIIIII!I III!IIIII FIN. FLOOR EL. 20' -0" BASEMEN EL. 31 4i 5 6I N0.18 g,<.. rf IIIIIIililill iillllill IiIIIIIII lilllllll l i:.I Ilil illll!lII ililllili iIIIIIIII EXIST. WALL n JAMB 1 1/2' r-0" Nitli IP .41111111111111V/1401111101111110 4111 CO WEST 1/4'= 3/4" 1 3/4 GWB. PAINT ACOUSTICAL PANELS PAINT RUBBER BASE TYP. I 24" METAL DOOR HARDWARE STORAGE DOOR 1/4-= 1 OR ONE SGL. DR. 3 MISSION CONTROL FR STORAGE 2' -0 X6' -8 "X1 3/4" W X W 1 1/2 PR BUTTS 179 US26D 4 1/2 X 4 1/2 1 EA LOCKSET 765L4 -L9555 US26D X CLS X WBX RHR 1 EA WALL STOP WC9X US26D 3 EA SILENCERS 65 RHR 90 DATE BY NO. DRAWN BY DATE JOB NO. DRAWING SCALE SHEET 'aC 0 GREGOV ARCHITECTS 1218 THIRD AVE., SUITE 1200 SEATTLE, WA 98101 206/622 -6990 CHALLENGER LEARNING CENTER SEATTLE, WASHINGTON A RPP OVED FOR BID BY THE MUSEUM OF FLIGHT CHECKED BY LG/TS 92 -122 APRIL 1, 1992 SECTION ION & ELEVATIONS 1/4" 1'- 0" A -3 i RETURN AIR I'l_ENUM CARRIER 38TKB060 5 TON C')NDENSINO UNIT OR EQUIV. • DISCONNECT DUCT RA GRILL FM DISCONNECT 208'1 1)A 30 )�� - --- -- 37" SERVICE ACCESS CLEARANCE \ 12" Iv,IN IMUM SIDE CLEARANCE 7- 22/10 WITH ACOUSTICAL LINING -» - - - -- TO RETURN AIR PLENUM (SF -4) ON 3/4" EMT - SUCTION LINE LIQUID LINE FD NEW 3' -6" DOOR HVAC PLAN CELING PLAN I L_ JFD A I 20/8 900HV --0 313 CFM 4x12 RETURN GRILL 953 CFM I 10/10 3/4 HP DX FAN COIL UNIT CARRIER 40YA060 OR EQUIV. 2000 CFM 0 0.45 IN.H20 10/14 x 10/10 - r _ _ PLENUM FITTING AHU • UPFLOW 16/14 1 16/10 PLENUM FITTING 20/8 9 OHV -0 320 CFM L F 20/8 9 0HV -0 320 CFM L_ f i •I 2� I ' �� 4 L f 5H °1 N0.16 � :"."' mil! ill 111111 lilt Ill! 1111!illl 1111111! 1111!III! 11111111 Ilfil�llll IIII�IIIi IIII!IIII IIII! IIII III!IIII IIII!LIII lilt 1111 1111 W3 1111 I 111111111 20/14 SERIES 1600 GRILL 953 CFM (MAKEUP AIR) 22/14 x 22/10 f PLENUM FITTING 24/10 . 22/16 '1050 10/10 L 22/10 Ill 16/10 I VD 16/10 14x14 TYPE MA 262 CFM (TYP) EXISTING FD Q WRAP AND IMBED IN EXISTING SLAB EXISTING DOOR J J TO PANEL C 1 208V 30A 30 1 208V 20A 10 RECEIVED CITY OF TUKWILA FEB 25 1992 PERMIT CENTER GREGOV ARCHITECTS 1218 'THIRD AVE., SUITE 1200 SEATTLE, WA 98101 206/622 -6990 IIMMNIMa BY +°HAi.LENCiER LEARNING CENTER SEATTLE, WASHINGTON APPROVED FOR BID BY THE MUSEUM OF FLIGHT DATE NO. DRAWN BY CHECKED BY DATE JOB NO. DRAWING DATE FEBRUARY 25, 92 92 -122 REVISIONS HVAC PLAN CEILING PLAN SCALE SHEET 1/ 4" 1'-•• 0" M -1