Loading...
HomeMy WebLinkAboutPermit B92-0090 - RUCKER FLUID POWER - REROOFQe 3 I 1 r\ O I tki . • ' • . • , • , „ , • ; , ' • " • . " , • ", • . tfi I.UCKER - rbu it) 1 3 OD9c) City of l it kvid i '' (206) 4313670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Permit No: Type: Category: Address: Location: Parcel #: TENANT OWNER CONTRACTOR 892 -0090 8- REROOF NRES 365 UPLAND DR REROOF PERMIT Status: ISSUED Issued: 03/17/1992 Expires: 09/13/1992 883650 -0070 Type of Occupancy: WAREHOUSE RUCKER FLUID POWER 365 UPLAND DR , TUKWILA, WA , , 98188 BOEING OREGON MESABI TRUST 1325 - FOURTH AVE. , SEATTLE WA , , 98101 CUSTOM ROOFING, INC 8001 FIFTH AVENUE SOUTH ,"SEATTLE, WA , , 98108 ****** i***** * * * * * ** * *. * * * * * * * * * * * * * * * * * * * ** Permit Description: INSTALL NEW:Bl1ILT UP ROOF OVER EXISTING ROOF Valuation::' 86,000:00 Total Permit Fee: 581.00 **********************1********* * * * * * * * * * * * * * * * * * * ** * * * * * * * * * ** • -, Permit Center. Authorized Signature Date I hereby certify that I- have read; and ,examined this permit and .knowthe same tobe true.and correct. All pro'vi'sions of law and ordinances governing` this. work will be complied with,, whether specified' herein or not The granting . o'f this permit does not presume to give authority to violate or cancel the prov,i s i ons, of any other state or local laws: regulating construct i on or the performance of work. Vain authorized to sign for and obtain this building permit. Signature: Print Name 17 Date: Title: gy res, This permit shall become null and void if the work is not commenced within 180 days from thedate of issuance, or if the work is suspended or abandoned for a p'erio,d of 180 days ;from..the last inspection Phone: 206 762 -0170 PERMIT NO. CONTACTED DATE NOTIFIED ,5" I-1-9 BY: (init.� DATE READY PERMIT EXPIRES 2nd NOTIFICATION 3RD NOTIFICATION BY: Lit. BY: (Init.) AMOUNT OWING - BUILDINGC'ERMIT APPLICATION TRACKING PROJECT NAME PLAN CHECK u crk -2 r VI t I c1 P w.QJ NUMBER SITE ADDRESS SUITE NO. Q D O aO 3 ( 0 INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE'FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) F . I Al SQUARE OCC. LO :D SQUARE ET OCC. OAD SQUARE OCC. OA . SQUARE g OCC. OAD SQUARE FE OCC. D TOTAL U • RE FEET TOTAL OCC LOAD DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. Detectors BUILDING - initial review O FIRE O PLANNING O PUBLIC WORKS O OTHER BUILDING - final review 3-16 REVIEW COMPLETED INIT: INIT: INIT: INIT: ROUTED CONSULTANT: Date Sent- Date Approved - FIRE PROTECTION: FIRE DEPT. LEI I ER DATED: INSPECTOR: ZONING: (BAR/LAND USE CONDITIONS? ( )Yes ( ) No REFERENCE FILE NOS.: MINIMUM SETBACKS: N- S- F- UTILITY PERMITS R EQUIRED? Yes N PUBLIC WORKS LETTER DATED: TYPE OF CONSTRUCTION: I li~ li6l. R llllENTS • >l .. :• :1�IMM� : N/A UBC EDITION (year): SITE ADDRESS SUITE # 365 - 369 Upland Drive VALUE OF CONSTRUCTION - $ 86,000.00 PROJECT NAME/TENANT Rucker Fluid Power /Eagle Automotive Bldg. ASSESSOR ACCOUNT # (See Attached) 883650 - 0070 TYPE OF ❑ New Building Li Addition U Tenant Improvement (commercial) U Demolition (building) WORK: ❑ Rack Storage © Reroof ❑ Remodel (residential) ❑ Other DESCRIBE WORK TO BE DONE: Install new built up roof over existing roof. BUILDING USE (office, warehouse, etc.) Office & Warehouse NATURE OF BUSINESS: Multi Tenant Facility WILL THERE BE A CHANGE IN USE? LL No U Yes IF YES, EXPLAIN: SQUARE FOOTAGE - Building: SAME Tenant Space: SAME Area of Construction: 53,700 WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? (3 No ❑ Yes IF YES, EXPLAIN: PROPERTY OWNER Boeing Oregon Mesabi Trust PHONE (206) 624 -4494 ADDRESS 1325 Fourth Avenue, Suite 1940, Seattle, WA ZIP 98101 -2510 CONTRACTOR Custom Roofing, Inc. PHONE (206) 762 -0170 ADDRESS 8001 - 5th Avenue South, Seattle, WA ZIP98108 WA. ST. CONTRACTOR'S LICENSE # CUSTOR *291M9 EXP. DATE 09/30/92 ARCHITECT N/A PHONE ADDRESS ZIP CITY OF TUKWILA Department of Community Development - Building Division 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 433 -1849 APPLICATION MUST BE FILLED. OUT COMPLETELY i ; HEREBY CERTIFY;THAT l HAVE READ AN J /EXAM INED THIS APP LIC A TION" Y RIJE AND t ORRECT, I AM AUTHORIZED TO APPLY: PERMJT, BUILDING OWNER SIGNA +RE PO AUTHORIZED PRINT NAME Steve Larson AGENT ADDRESS 8001 - 5th Ave. So., CONTACT PERSON DATE APPLICATION ACCEPTED b Steve Larson BUILDIN PERMIT APPLICATION FEES (for staff use only) DESCRIPTION BUILDING PERMIT: FEE PLAN CHECK FEE BUILDING SURCHARGE ENERGY SURCHARGE OTHER:. TOTAL - AMOUNT RCPT # 576.50 4.50 •581.00 v DATE DATE APPLICATION EXPIRES D KNOW THE SAME TO B DATE 3/13/92 P 762 -0170 CITY /ZIP Seattle 98108 PHONE SAME APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 433 -1851 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 433 -1849. 03130/86 COMMERCIAL NEW COMMERCIAL BUILDINGS /ADDITIONS 0 Completed building permit application (one for each structure) Assessor Account Number' Two sets (2) of the following: El Specifications Q Structural calculations stamped by a Washington State licensed engineer :. n Sails report stamped by a Washington State licensed engineer r Topographical survey Energy calculations stamped by a Washington State licensed engineer or architect • ! descliptron Worfdng drawings, .stamped by a Washington State licensed architect, which Indude • Site plan Architectural drawings • Structural drawings •: Mechanical drawings • Elevations Civil drawings • Landscape plan Completed utility p M permit application (one tor:errtlre project • L Six ( 6 ) sets of civil drawings • NOTE • • See utility pennitappllcation and checklist for specific utiln : submittal requirements RACK STORAGE Completed building permit application Assessor Account mber Two sets of plan w hich include; n Building floor plan sho Entire space where radcswiilbe Inca p + Exit doors • Dimensions 01 all aisles • n Tenant space floor plan showing rack storag layout, aisles an exits NOTE :. Include'dlnrensions of racks ( height, width surd length), alder: and exit Ways on plan : C Stntatur c stamped by a Washington State licensed engineer (rod *storage W and over).: RESIDENTIAL NEW SINGLE- FAMILY DWELLINGS /ADDITIONS n Completed building permit application (one for each structure) E Legal description E Assessor Account Number Two sets (2) of working . drawings, which include: • Site p! ^1 • Foundation plan • Floor plan : • Roof plan • Building elevations (all views • Building cross - section • Structural training plans C Washington State Energy Code data Completed utility permit application E Six (6) sets of site plans showing utilities NOTE: Building site plan and utility site plan may combined See • ut!lfty permit application and checklist for specific submittal requirements.: Adaktkinal topographical and soils information may be required if unique site conditions. SIsBMITTAL CHECKLIST •• COMMERCIAL TENANT IMPROVEMENTS E Completed building permit : applicatlon (one for eadh, structure or : tenant): Assessor' Account Number .. • Two (2) sets of construction plans, whlch•:includo; Site plan • !Location of tenant apace • Existing anti proposed parking,;; E Overall building plan Tenant:location • :Use afadjacent (common wall) tenant •: Overall dimensions `of building.or square,footage • Floor plan of •proposed tenant space •Tenant space plan with use of each room :labelled. >; •.Exit doors, egress patterns • New walls, existing wall and walls to be demoiished. Construction details Cross.sections showing wall construction and method attachment for Floor. and calling SWcturat calculations stamped by; a Washington' State licensed ;. ;; engineer may be required if structural workis to, be :done (2 sets) NOTE: if anyutrlrtywork is to be acne;: submit separate 404 permit application and plans RESIDENTIAL REMODELS ;' n n Completed building permit application (one for each structure) C Assessor Account Number n Two (2) sets of working drawings, which include • Site plan r: Foundation pier • Floor plan. i eeof plan .. • Builtding,elevations. (all views) •:Bt iiding'cross- section • Structural framing plans: NOTE If any utility work Is to be done provide : utility . permit application • and plans must be submitted :: REROOF Completed building permit application (one for each structure [7/ Assessor Account Number Narrative describing existing roof, material being removed, and material being installed .. ;NOTE A`certifcation letter is. required prior: to final inspection and si off of the permit • ANTENNAISATELLITE DISHES Completed building permit application assessor Account Number. Two (2) sets of plans, which include Site Plan (showing building and location of: antenna/satailite.dish) Details antenna/satellhe:dlsh.and method :of attachment nsed Structural calculators stamped by a Washington State lice engineer maybe required REROOFS Completed building permit application (one for each structure Assessor. Account Number Narrative describing existing roof material being;removed and material being installed >'. • NOTE: A certification letter ls required prior to final Inspection and 519,77. off of the permit • ro e f ► ••cress :2( , gram 9 l je -1 YPe o , pact on: �� (/tred I.teC:ge.: '—/a Special Instructions: �. , q S Id'V Date Wanted. Z g � q� �. p.m. (arr m. Requester: Phone No.: ..7 & 2 — 0( 7 0 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes, COMMENTS: Inspector : INSPECTION RECORD Retain a copy with permit Ok_. ❑ Corrections required prior to approval. 2 PER -2g _9 ❑ $30 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Gentlemen: aatem Rao ilaff, 8001 5TH AVENUE SOUTH SEATTLE, WASH, 98108 PHONE 762-0170 City of Tukwila 6200 Southcenter Boulevard Tukwila, WA 98188 RE: Rucker Fluid Power Facility 365-369 Upland Drive Tukwila, Washington SUBJ: Bldg. Permit No. B92-0090 Reroofing Completion Custom Roofing has installed a new built up roofing membrane in compliance with the following specification. Owens-Corning Specification # 31-IC Insulation - 3/4" Fiberglass April 28, 1992 Per Owens-Corning specifications, this roof has a Class A rating over 3/4" fiberglass roof insulation. Please see attached specification sheet. Sincerely, Custom Roofing, Inc. E. L. Larson, C.E.O. '• • • • UL Class Bitumen Type 33 -IC 31 -IC 30 -IC Materials per 100 ft lnterply • , . Felts . • 3 plies Bitumen 0 -1/2" 11, ill 75 lbs 1 /2 -3" 111 75 lbs 3 -6" IV 60 lbs Surfacing Bitumen ' 0 - A 111 25 Ibs • 1/2-3" A Ili 25 lbs 3 -6 ". C** . IV 20 lbs • PERMA CAP 78 Ibs • • Nominal installed lb /100 ft (Below weights exclude roof insulation and are provided for system design consideration) New Construction Guaranty (Specification must be over FIBERGLAS roof insulation to qualify) 33 -IC 31 -IC 30 -IC 205 . 205 w /PP -IV. ; .. 211 w /PP- WP. '.. 211 - 10 yr unlimited 10 yr penal sum 10 yr penal sum • — ' • OWENS, CORNING FIBERGLAS : }�,�•� • Insulated /Cap Sheet Application of insulation; ': = Apply roof insulation in accordance with specification requirements. Insulation joints should be staggered In one direction. .:: For multiple -layer applications, joints of each layer should be offset a minimum of 8 inches from all joints of the preceding layer. Application of Plies ,. . Embed three plies of PERMA PLY in shingle fashion (starter sheets required), lapping 24-2/3 Inches into uniform solid moppings of hot -�` asphalt, using a nominal 25 lb /100 ft per ply. Plies may be left ' exposed up to six months without surfacing.' Application of Mineral Surface • . .. Embed 12 -ft. lengths of PERMA CAP into a uniform solid mopping of hot steep asphalt, using a nominal 25 lb/100 ft PERMA CAP end laps should be staggered 3 ft. The re -roll /roll -in method of application is recommended to minimize fishmouths and blisters. 33 -IC All Ar ®as 31 -IC All Areas PERMArPL -IV or PERMA PLY No. 11 30 -IC Area 111 PERMA PLY -WP 30 -IC •• FIBERGLAS roof Insulation only 7.1/Ow General Note All general instructions contained In the General Requirements section of the Fiberglas Built -up Roofing Specification Manual (Pub. #1 -RW -5393) shall be considered part of this specification. drainage Roof decks must be g raded to drain all water freely to drainage fittings, Drains shall be sufficient in number and size to assure rapid. • elimination of water from the roof surface. • . Nailing . •• Treated wood nailors are required on inclines exceeding 2 inches per: •',. foot to help secure insulation and roof membranes to non - nailable '•: ` :. . decks or to decks with insulation. Naiiers should be the same thickness as the insulation and should be installed perpendicular to the slope on ' 20 foot face -to -face for slopes up to 3. inches per foot and 4 foot faco -. . • to -face for slopes greater than 3 inches per foot. Felts are to run parallel to the incline and must be secured at.each nailer, 12" in from.: the back t X ~ edge of the felt. Each nail must be Iverediy ; ,, , plies., . fi.Y1;'}',i j.F;c "vr. I lime E u v:. „.M. , I ,,. • ' I w' I � icia Tb : . • '�'� KAMA PLY esek of Ply '45. To N.M See Flashing Section and the Owens- Corning BUR Reference Manual: • •Consult your Owens - Corning branch office for local product availability. ,... � . • • • Project; �v K r 'J icy P Ty p e of Inspection: 1(IQ — Rern0€ Address: -bq Up iand to Called: .- , i .. 1 `9 Special Instructions: � Date Wanted: r' 3 — � ; Cl a am. p.m. Requester: ' r e \tp Loomn Phone No.: ._7 (OrZ — 0 f n SPE 10 0. ❑ Approved per applicable codes. nspector: °cep o.: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Date: / ► PERMIT NO (206) 431 -3670' ❑ Corrections required prior to approval. COMMENTS: C .c1 ro.-`'-r r CAA _4'� ,. 1`— - sp cL"W4. 3 - » -9 ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Total Fees: Total All aymentm: P Bmlmncm; • 581.00 581.00 .00 ^r T � / �� � '� �� k****^***** *******+**+*+**********A****+*********+************** %TY OF TUKN%LA WA` ° r '� TRANSMIT +**+*********+******'**++***+*******+**+****+*****+ *********k* TRANSMIT Number: 92000200 Amount:' ' 581.00 03/16/92 � 15o19 Permit No: 892-0090 Type: g_WEROOF RERDOF� |ERMI --- `` Parcel No: 883650_0870 �� Site Address: 363 UPLAND DR Payment t oymenn Me hod: CHECK Notation: CUSTOM ROOFING Init: G.- B + ** Account Code ' Description Poid 000/322.100 BUILDING NONRES , - 576.50 000/386"904 STATE BUILDING SURCHARGE ` 4.50 Total (This Payment): 581.00 GENERA 576°50 GENERA 4.50 TOTAL 581 CHECK 581.00 CHANCE 0.00 7967A000 15:20 Permit No: B92 -0090 Project Name: RUCKER FLUID POWER Address: 365 UPLAND DR-, * ** * * * * *k * * * ** k ** * * *. * ** ,r. CITY OF TUKWILA REROOF CONDITIONS * 'k, * dr ** **k';kk•k***':kk * * * * ;**k ******•k•k *•k*k*k*** THE FOLLOWING CONDITIONS ; T(7'" RE -ROOOF PERMITS: , r 1 A11 roofing projects wi 1 ; be, accompl isl ed in '�� {compli,ance with • Appendix Cha `` 32 of ;the Unifor Building' Cod`e.�•( .UBC)`�`' 2. Inspections NeW r of, coverings shall not be applied without first obtaining a pre roofing °,inspection from the Building Division anl;. written: approv,al1 f:ro,r Building Inspector' +. { The pre;raofing'•inspection Shallr•;pay,particular att'er tion'.to evidence of accumul�a,ti`on of water n ,Where extesiv ponding :! of.,, f's, ap an. analysis of ,.the roof struoture {for k compl with.'Secti,on`�3207, UBC, shall be made and corrective measures,'' such•ast' relocation of roof drains or , g scuppers., res l op 1 ng of the', 'oo f•w'or, : structura 1 l�chang,es , , sha 1 1 beLeaccompl lshed. An inspectionGcoyering the ::above l ist`efd to0q'sprepared by a qual if iedsspedial inspector, a's determined by the Building,:.Official,;may bey =accepted .i'n`s lieu ;01' the pre - inspection by the Buifld'ting In-'spector. 1 B. A ,final inspection and approval shall, b`e obtained from % Bul,id�ing ` D1.vision •when the re- roof�,in'g is cojnplete; As cond.iftl.on of the final` ° ' inspection for roofs that require a fire retardant roof covering under the provis of Table 32 -A, 1988'UBC, the roof f i,nstalller shall prov;i,de the inspector wi0,a written'-statement indicating'' the following (or something 'lmilar). I HAVE INSTALLED A ROOF MEMBRANE PSSEMHL.Y4` ~INCLUDING INSULATION IF APPLICABLE, CONSISTING OF (MANUFACTURER), SPECIFICATION # DATA SHEET ENCLOSED, WHICH MEETS OR EXCEEDS THE REQUIREMENTS FOR CLASS A OR CLASS B ROOFS. THIS ROOF WAS INSTALLED AT (ADDRESS), UNDER CITY OF TUKWILA PERMIT NO. (The statement shall include the name of the roofing company that installed the roof, signature of installer and date.) the a March 10, 1992 • Boeing Oregon Mesabi Trust 1325 Fourth Avenue Suite 1940 Seattle WA 98101 -2510 Attention: ...Reference: Dear Jack: Dean B. Ratti Jack Link • !R AT T I SWENSON 'P ERBIX IC LARK 1 • Building 365 -369 Upland Drive Re- roofing Tukwila, Washington If I can be of any further assistance in this matter, please feel free to call me. Sincerely, RATTI SWENSON PERBIX, Inc. Consulting Engineers RECEIVED CITY OF TIIKWILA MAR 1 6 1892 PERMIT CENTER At your request, I have reviewed the structural system for the referenced building to determine the feasibility of adding a new roof membrane over the existing. The analysis was performed using the original structural drawings by Engineers Northwest dated July 14, 1948, revised August 1, 1978. Weights for the existing and proposed roof membrane were taken from Custom Roofing, Incorporated's letter dated March 4, 1992. It is my opinion that the structure can safely sustain the additional weight of the proposed roofing system within the allowable stresses of the materials used for the construction of the buildings. The analysis was based on the original roof weighing 1.25 psf and the new roof system weighing 2.75 psf. A Professional Service Corporation 1411 4ih Avenue Building, Suite 500 Seattle, Washington 98101 Phone 206.624.8687, Fax 206,624.8268 Lot 7, Upland Tukwila Industrial Park, City of Tukwila, King County, State of Washington as recorded in Volume 104 of Plats, pages 8, 9 and'10, records of said County, Recording No. 7708290789. ONMta -- ?klei N4 A4r '7"6Lu�r • i TAx ZOT Nth Ps 36, so — oo-70 1 // 31-0 ¢ 2a,F' Sine. P s y LEGAL DESCRIPTION s/ �N 0 RECEIVED ' CITY 0= 71 IKWILA MAR 1 6 1992 PERMIT CENTER