Loading...
HomeMy WebLinkAboutPermit B92-0407 - BOEING #7-35 - REMODELr 0 0 • I : • • • ;'.•• 4,1.t 71 P41q6 41 -35 City of ?itzzkwitA, Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: B92 -0407 Status: ISSUED Type: B- BUILD Issued: 12/09/1992 Category: ACOM Expires: 06/07/1993 Address: 12674 GATEWAY DR Location: Parcel #: 271600 -0020 Zoning: M1 Type Const: V -N Gas /Elec: Wetlands: Water: N/A Contractor License No.: KBINTCC160QF Permit Center Authorized Signature Date' Type of Occupancy: OFFICE Slopes: Sewer: N/A TENANT BOEING #7 -35 12674 GATEWAY DRIVE, TUKWILA, WA:;;98168 OWNER KAISER GATEWAY ASSOC BEDFORD PROPERTIES, 12870 INTERURB :TUKWILA WA 98168 CONTACT WILBER LISA Phone: 206 393 -3097 P.O. BOX 3707, M/S 6Y-59, SEATTLE, WA 98124 CONTRACTOR K B INTERIOR CONSTRUCTION CO. Phone: 206 889 -3126 4055. LAKE WASHINGTON BLVD, P.O." BOX 849, KIRKLAND, WA 980830849 ******************************************** * **** * * ** * * * * ** * * * * * * * * ** * ** * ** Permit Description: REMODEL AREA TO PROVIDE MORE :OFFICE SPACE. SETBACKS Units: 00 Front: '0 Back: Buildings 001. Left: .0 Right: Fire Protection: SPRINKLERED UBC Edition: 1991 Valuation: 14.,430:00 Total Permit Fee: 271.'80 ****************** * * * * * * * * * * * * * * * * * * * * * * * * * * * ** (206) 431 -3670 I hereby certify that I have read and' examined this ; ankno.W: the same to be -<true and correct. All prov,�isi "ons, cof; law'and` ordinances.,. governing this work will be complied ; w`ith, whether`specif"ied herein or not The granting:,: of this. ; permit does not presume " to"' g authority _,to violate or cancel the:., provisions of`any other state or ;-local laws regulating construction or: the per or ance of "work. , ". I am' author..ized toY for and obtain this b, 11,0ng pe mi Signature:' I �_�_ Date: r_9, Print Name: This permit shall become null and v'o'i"d if'°' le work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT NO. CONTACTED • DATE READY DATE NOTIFIED � - � �� BY: (init ) PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING I („ t i� r , .� ' i .Jl_) 3RD NOTIFICATION BY: (Init.) . BUILDING( ?ERMIT APPLICATION TRACKING PLAN CHECK NUMBER gq& - Owo-1 ..... .................. . ............................... DE PAfiTME NT x BUILDING - 13- initial review FIRE O PUBLIC WORKS O OTHER PROJECT NAME SITE ADDRESS ∎Z 1 1 0 PLANNING I � (g BUILDING - final review 1 "1 I vt2 REVIEW COMPLETED INIT: Ai ROV ED 1'Z / I k OLTED 3Qeri -?- s la (ct`1-i at�ew INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) FLO .> i SQUARE FEET TOTAL ............... ............... OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. CONSULTANT: Date Sent 4_1i, FIRE PROTECTION: P S•rinklers Detectors FIRE DEPT. LETTER DATED_ r Z INSPECTOR: INIT: ZONING: REFERENCE FILE NOS.: MINIMUM SETBACKS:. N- UTILITY PERMITS REQUIRED? PUBLIC WORKS LETTER DATED: 1 I L , C TYPE OF CONSTRUCTION: INIT: REQ UIREME NT / . COMMENTS_ BAR/LAND USE CONDITIONS? )Yes S- Yes SUITE NO. Date Approved - N/A UBC EDITION (year): TOTAL OCC. LOAD PROPERTY OWNER \ � Gam . �.� A5 ,� A .- ( E PHONE .. \cY ADDRESS 34 i-A 7 A�LO 'Q�7. 1.�4GAge�(`c� LA ZIP 1 CONTRACTOR PHONE ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT - PHONE ADDRES ZIP 2 A ... 21z,--7 fiJUU 0ourncenrer creurevara, I U? W1Id vvr+ .70 I oo (206) 431 - 3670 DESCRIPTION AMOUNT RCPT < >'; DATE BUILDING PERMIT FEE (pM PLAN CHECK CC NUMBER D J�L LAN CHECK. FEE BUILDING SURCHARGE 111111111MVal APPLICATION MUST BE . FILLED OUT .COMPLETELY OTHER. TOTAL - : l' j(1 SITE ADDRESS SUITE # VALUE OF CONSTRUCTION - $ PROJECT NAME/TENANT sab -.CL.1 .-- ti $ ' ��1 ASSESSO ACCOUNT # ,1 t . 1101 - OD ZD TYPE OF • New Building • Addition WORK: 0 Rack Stora•e 0 Reroof F. Tenant Improvement (commercial) • Demolition (building) • Remodel residential 0 Other: DESCRIBE WORK TO BE DONE: I P-- V A. 1 'cc Pal I l c7� i-- DV.-- CPF IC S — BUILDING USE (office, warehouse, etc.) nr-Fc.?�. \IIN -,nus_ NATURE OF BU INESS: G (L-J I�- t S .a WILL THERE BE A CHANGE IN USE? o 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building:, 800 Tenant Space: IL, k o I Area of Construction: 1Op WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR FAZARDOUS MATERIALS IN THE BU ?LDING? lA No 0 Yes IF YES, EXPLAIN: CITY OF TUKWILA Department of Community Development - Building Division EBY CERTIFY <THAT:; TRUE, AND :CORRECT,; SIGN BUILDING OWNER OR AUTHORIZED AGENT PRINT N • E 1 1 j � ADDRESS -? \ L 2 c .. ) LA Jci CONTACT PERSON LA -\ APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED BUILDING PERMIT APPLICATION PI I T(O t ANI K1!IQ!'W THE«8. .:.:...:.. DATE APPLICATION EXPIRES DATE PHONE ,p _ 7 CITY2ll - - `gNZA•1,20 PHONE SUBMITTAL CHECKLIST COMMERCIAL : : ... . . , • . NEW COMMERCIAL •• au;LpiNqyikantriop43 Ej Completed building permit application for ea . . Assessor Account Number •:: •••. :: • :•":• • • ... . • • Two sets (2) of the following . • Epecifications . :n: Structural calculatIonS.:staMped by;ti Washington ••,engineer: ::„ •.. Soils report stamped by a Washington State licensed engineer ". • T opograp hi ca l surey Ej Energy calculations stamped by a YllaShirigten:Btate licensed engineer or architect : ;:: ••••••• • :••••::. . , .;... „. „„„ „ • „.„ „. Site Atchltoctural drawings Structural drawings • •:••••••••••::::::V::::::::":"."•:::•••••••.• Mechanical. drawings ••••••••" •'••••• Completed utility permit appllcation (one for entire pmject) •••••.$iii; (6) sets of civil draWingi:i•• NOTE petthitoi:ii4fidatioir ..... . . . RACK STORAGE • • •"••• • •"•••• I I • • • aoolicabon C°111Pl!te. tNOrpl)e■- • tWSi igY se •• ••••••••••••• • • .• • El Assessor floc) r 0100 ••••••... • 11). • and . •:••• .. • au rack stor flans space floor plan showing . .• , • laagth), ofeite Its NOTED:: ll ways ral‘,,,claioin!. . s stamped by ver)7 Was hington State licensed and cal culation s 8' . engineer (rack iterepe and o . .. . . RESID • .! ... ......NEW SINGLE FAMILY DINELLJNGE/ADDITIONS ,.....• .•...........:::....,.................'.. ...... ... eschat .. - ... ' onnit nplicetle(eneloealden)) ccimpieter1 bij:i.fing 1 a pplication - a. ., . .. ...... :..... ...."..... .. . Legal desciiplior. .Working drawings, stamped by. a Washington.BtateliCarised • ardhiteCt, which include: . , . • • showing Two sets (2) of working drawings, which Include Site plan *°•441414*"8" R plan • • •‘•.:;: • • . . . •••:• • • . • • Building elevations (all views) • • • •SButiVitdcittIngralcross framitIgplans . • .000tion . •.• ••••• •••••••• ••'• • . . . ,.. E . Washington State Energy Code data .... :.:., ... • ......, : , .. . Completed utility permit applicationiatil• utilities ... . ... .: ..:.. : _.-- . .. . ' . rai Six , (6) se of site plans show N p lan may be co mb regu ned 1 •• re S m ee NOTE:. Building site plan and utifitysitep specific submitta i ents.: A l utility permit application and checklist for spec Additional topographical and soils information may be required if unique site conditions. • ,• 1Et,11:69r)s11#!!!P : • . • fl Completed bulIcng permIt application (one for each or Assessor Account Number TWo Site plan (2 se ts spa _ c h a ng e ....: EJ • Existing and .• Tenant ,",::;•::••;:.i.:••:::,••:•;••• • wai 49e2 i.tiOricSif:0 840 L. tiona . .. . :U80 of ........ . . . • Tenant . •:>••:••• . plan with use of each room labelled Ex it doors. floor and S Cross sections showing wail attachment ce iling for 411971 OOF Completed building permit apphcadon (one for each structure) Narrative describIng existing roof material being rerr :matarlal being Installed .. . , OofV1 'Roof plan • Building elevations (all views .:: ••.:.•:•:,§1racteral framing .... . . • • : •.; •• • • ev0f40'; 4111111M=MI " • .. .. RESIDENT , . r. . ••••: . • •-•••Slta:• •:. . ••• •••••• :::, t i n y u t i l i t Y * . O r k i e l e • b e : ' 0 9 n e ' O r o y i d e t r t i l i t y pemlit• application i;lariS•Mual ••• • :L... • ]..• . • ......... . . . • „ . . Completed building permit application (one for each structure) C Assessor Account Number , • •:.; : :•• • • : • : • Narrative describing existing roof material bono and ;: • ::;. material being installed,•: • •:•, ••••••• • , • •• : • : .• • • : NOTE: A certiffct0On letter Is required prior to final Inspection andsign ofl of the permit. . • *****,*,* ***..k ****** *** ***************s***4,******************* • C TY OF .ILIKWILPI, WA T[tANSM GENERA 105.30 T ' ' 105 : too pmit, 9.20430 A in'O.irit 0 9 2 3'"i: - CHECK • • • ;, • • CHANGE , 0 00 Permi Type , Purcel NO:; 271600-0020 , , i 52,7A 000 . ‘4itE.:•AitclrOssis:"1267A GATEWAY DR „ . . Is • fe;t4cle' rie4r it;' * * * * 4r 'ft* * * JcSie **4 A ** * 4r* $ .*)Ii r * POCatAr De&ertPtiat1 ” ' Paid 11 000/345.30 . • PLAN CHECK NONRE8 : 1 05. Total . ((This Payment): 105 :.30 PayMent::kethed CHECK Notation: DPEING:QUM,PAN In i ,Total Fees: 271.80 Total (11 1 Payments: 105.30 Balance: 16'6.50 irisk*A.***ic****:***A4*****************************.le**1c**********4!* CITY OF TUKWILA; WA ; Reprinted: 12/09/92 141:01 TRANSMIT **.A TP.ANSM/T Number: ,92001398 Amount i , 166.50. 12/09/92 '14:00 Permit, No: 1392-6407 • TyPe:' -B U IL D , BUILDING PERM 'Parcel 271600-0029 • ; „ Site 'Addreis:; 12674 GATEWAY DR • Payment Method: CHECK Notat;i on: .BOEING " SLD GENERA 166.50 TOTAL 166.50 CHECK' 166.50 CHANGE 0.00 5910A000 15:33 _Account Code. . Deseription 000/322.400 BUILDING - NONRES• 162.60., 000/386 STATE. BUILDING SURCHARGE , 4.50 Total (This Payment): , 166.50 Total Fees; 271.80 Total All Payments: 271.80 Balance : .00 Address: 12674 GATEWAY DR Tenant: BOEING #7-35 Type: B -BUILD Parcel #: 271600 -0020 CITY OF TUKWILA * * * * * * * ** * * * *•k * * * * * ** *ail * * * * * * * * *•k * * * * * * * ** k * * *•k * * * *•k * * * *`k* * ** * * * ** *•k* * * *•k ** Permit Conditions: • 1. No changes will be made to the plans unless approved by the Architect and the'Tukwila Building Division. 2. :Plumbing permit shall be obtaine,d;.,.t,h the Seattle -King County Department of Publfic {e,alth Prr u will be • i nspected by that 'age nn'T`ud ing"a l i �: a a'� i:; i pipi (296-4722) e;Y ,M Elect * `} /sue x Y! ''� ;�`. rical per ry i=t ::shal b l `e ta hrou h the ton h.� in • � ^` +" r{ � ti { ei ob Bti t : z �.ns ^ i g �. f a i g State ' D i v i s i o i ,d f" La bor ' ; d Industrie and a l 1 J e l e'G t r,i a 1 work will be!� ',,i�nspected��b Oat ag cy 48 • Al 1 en `(2 5 m e , c a90;+!/ r`} tS' : 1' 1 • rp s ¢ � ' h meal wor�c�, s,�ral1 b.e��'Under se pe�r��tit through the Gi t , Tu kr �4, l��� .�„ x k Jy r� x � � � `�''�' E �"� r �,.w 5�1!T -� fs � f ;. ' All per its„ Inspection recor ', approved',,:pla'hs�sh,p1l,, •mainta y ,' , d available at th8�',ipb sit`e(r prior to the 'stett of any •c trt uction. i These, d�ocupients,,are to b.e maintained:' avai a` � e urlti l final inspection ,arpproval is granted:`'' . i Any. ,ne' ceilin ;grid and 1 igh.:,4i`xtu.r ~ : e i nstal 1ation is'' ;re u�1'ed to imee�t l ater e l���b.t ac .i re q � , g qu•.i remen f Se,i s m Z 7 r J o n s t @7 1 •y " + . � <,:., 1 t fi1 s } (k,. .. . :Par io e a r �� n' walls 0,tacti di ; ce t i i,n r019 . must be late br e5,:f if ove inr^; u ed•ght (=8) '\feet in A c. *� , q An xpose, slatiri ns.a ?ing mate �i a haw a Fl r d i d �} b tali: l s l l have _ s r p e Rat1ng of 2 01:41$70- , ,, and r. ial 1a11 bear aidenti� ` ' fic a oneo Cwing t e' ifir /per f;�or.ma`nc:eMrati,ng thereof . 'Ail onstrubtVon td. d in''+conft r` ; nano with approyved'' "`�7 ,plarlq and ` r qu'1,rements' of the Un `c rim,, Bu tl.d ing,. Code '419.44 '.'Edit )�a-s amended'.by the Washirn.g tin. S'•tate Bui ldin Code, Unif M0.c`.ranical Code .(1991 Edi io)'�; ' and 'Was Ener t o3 (x`199 Second Edition f y 4, :`Valid ## of Permi t4 The issuance oft a ' m . N r �' perr�ii;.. p.r�approva1 0 plans,.,' s ecificationsr and computa fans i4, lA 'not be' 'on -, strued `` ,a + e.`rnit xior, :or:'an...approval 'of.v a lat; for of .any of t e pro bisio.ns o this code''or of' .'14'any 'an otIe ' �s� � � y t . �.�r ,� t ,� ,rs t Jtirisdictionp,4sNn4per t presumAng t �' rve ordinance authors ty ol^,,1'{., ,pl ate or :cance•l the rovis i ons of th .s odde s h a 1 1 b e. v a 1 ii'd� `° „4 p JH. Permit No: B92 -0407 Status: ISSUED Applied: 11/1 Issued: -12 /09/1992 • ro :: T -...55 ype o ns : u ion: ....1 trI J Sp: gal Instructions: �Q ,l (P77-725' , " — t gate Want:.;,. F 2 13 ,^ am. �:m: Requester: , j ' ( l Phone No,: � EGTION N Approved per applicable codes. COMMENTS: nspector: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 431 -3670 0 Corrections required prior to approval. '. e: 2r; 9 3 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at. 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Project 1- , s Type of Inspec ly r'y k Addres f f C') G1.�2� Date Called: Special Instructions: ■ Y I (`d ,. MO I M t/� Y V bate Wanted: I', - 2- e.. am. p ,m. Requester :� / t Phme Na: " t r S (1-- 4/ 1 v1 7 INSPECTION RECORD Cl Retain a co with permit PY Pe CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: /2/ scu No.: 0 Corrections required prior to approval. 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. e: ?-(5407 PERMIT NC1./ (296) 431 -3670 ro"Fr lec" t , 3 Type of Inspect u1/4)0,\\ Y' 50,5k Date Called: : � Q. -a3 ° m. ���� I Gate SpSpecial Instruc o ns: 0 l -1` k -k--er oon 4 n Date Wanted: L ` ✓ L.4.. ��`� am. Req uester: �ItI Phone No.: q %, Hug INSPECTION RECORD Bga0-101 Retain a copy with permit Rmr N 0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431- 670 s K Approved per applicable codes. COMMENTS: Inspector: 0 Corrections required prior to approval. Date: ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 SQuthcenter Blvd., Suite 100. Cali to schedule reinspection. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD C Retain a copy with permit ❑ Corrections required prior to approval. oId7 PERMIT tr0 (206) 431.3670 ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection; fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: .: J Date: I .. ype o nspect ' ruct " ty - i( H :p Ad NI , ( D , . � Date Called:/ _... Special Instruct lot • r ntn ' F 16 , _ .: . r ++ Date Wanted IA ..-- —_,,z: to Requester L ,.: No ,: q6 n4 L t l i 9 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD C Retain a copy with permit ❑ Corrections required prior to approval. oId7 PERMIT tr0 (206) 431.3670 ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection; fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: .: J Date: — P role d:AIPP- OtAi , 4 * - - 7 -35 Type ot Inspection. ' - r tat/int/A-0 Date Callaci: — rd- 6 1?" -- Address. r. J / ep / 7 ltrA) Special Instructions: -- Date Wanted: .,A.O. . Requester: 13 ; i / ‘INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 E3R-oeio, (206) 431-3670 Appioved per applicable codes. 0 Corrections required prior to approval. %IP COMMENTS: 704 oz._ /0-7 o $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100 . , Call to schedule relnspection. xry' vti w», �...nn ;anu." - , Y 7,rr..,{ q - r, �r�rrt »m^y�v..pnr,. 7 r-'ni r -vo Vt:4,;„:,:+11..r.bry inter1`;14 'Pi,i 1 .'t?7.7.`,; ".4`. City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name C.t° /A,'C - Address /. 2 4 74 Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: 60.5/9 d Cam, 01 Autho' ed Si • ature FINALAPP.FRM Gary L. VanDusen, Mayor Control No Permit No. Suite # T.F.D. Form F.P. 85 City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 John W. Rants, Mayor Fire Department Review Control #692 -0407 (512) December 3, 1992 Re: Boeing Company Building #7 -35 - 12674 Gateway Drive Dear Sir: The attached set of building plans have been reviewed by The Fire prevention Bureau and are acceptable with the following concerns: 1. No point in a sprinklered building may be more than 200 feet from an exit, measured along the ;path of travel. '(UBC 3303(d)) Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more.. (UBC 3304(b)) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 12.106(c)) Obstructions, including storage, shall not be placed in the required width of an exit, except projections as permitted by the Building Code. Exits shall not be obstructed in any manner and shaii remain free of any material or matter where its presence would obstruct or render the exit hazardous. (UFC 12.104(a)) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit hardware and marking shall meet the requirements City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 2 John W. Rants, Mayor of the Uniform Fire Code. (UFC 12.106 - 12.111) Internally illuminated exit signs shall have both bulbs working at all times. (UBC 3314(c)) When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of. egress.. (UBC 3314(A)) Aisles leading to required exits shall be provided from all portions of buildings. The width and spacing of aisles shall be maintained at all times. (UFC 12.104(b)) 2. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 25 heads shall have the written approval of the W.S.R.B.; Factory Mutual, Industrial Risk Insurers; Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal.to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1528) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and'tests. (UFC 10.503) 3, Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type..of construction, draft stop partitions and roof coverings shall be maintained as .specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.601) *ILA ''q S.� City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number special fire permits may be necessary depending on detailed description of intended use Any over ,looked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. • John W. Rants, Mayor r► DATE //-- . PROJECT NAME C N 2 L 4e ✓`/ r F -4 . 7 4 17 ADDRESS /2b74* /' f C/ 11 . �v CONTACT PERSON Z.-457'A 4 ' �L . PHONE ARCHITECT OR ENGINEER 0- �l/��- PLAN CHECK/PERMIT NUMBER eft - TYPE OF REVISION: SHEET NUMBER(S) bet/67 ,1A /� r ri/ f f4-,'W "Cloud" or highlight all areas of revisions and date revisions. SUBMIT'T'ED TO: A - E Y V -- '�� / CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * RaillSEIONI SUE ,11TTAL * z: RECEIVED CRY OF TUKWILA NOV 3 0 1992 PERMIT CENTER * * REVISION SUB MAL * DATE CITY OF TUKWILA 6300 SOUTHCENT'I'ER BOULEVARD TUKWILA, WA 98188 PROJECT NAME ADDRESS CONTACT PERSON L- ■` L- PHONE __ 93- 3 ARCHITECT OR ENGINEER — ?- 4\L... PLAN CHECK/PERMIT NUMBER — 04D TYPE OF REVISION: .cya (0 - < ot,4-L,L,441 SHEET NUMBER(S) 4.1D "Cloud" or highlight all areas of revisions and dat revisions. SUBMITTED TO: ' PIM 2. 3 199 COMMUNITY NT CITY OF TUKWILA Id: ACTP125 Activity Table Processing Permit No: B92 -0407 Status: PENDING F1 =Help, ESC =Exit current screen. ft Keyword: UACT User: 1677 12/01/92 BUILDING PERMIT Tenant: BOEING / #7 35 `'x' Address: " 12674 GATEWAY DR Type: B -BUILD Vers: 9101 Screen: 01 Base Information Parcel No: 271600 -0020 Owner: KAISER GATEWAY ASSOC Validated By: SLB Plan Ck Approved: / / Status: PENDING Applied: 11/13/1992 Issued: / / Active /Inactive: A Completed: / / To Expire: / / C of 0 Issued: / / Bus Lic #: Nature of Work: REMODEL AREA TO PROVIDE MORE OFFICE SPACE. Location: Category: ACOM (N= NEW /A =ADD /ALT + SFR,DUP,TRI,APT,MH,COM,IND) Zoning: M1 Gas /Elec: Census Code: 437 # of Units: # of Bldgs: 1 Pub Own:N Streams: Slope: Wetlands: Water:N /A Sewer:N /A Setbacks - North: .0 South: .0 East:,;,;,; , „West: .0 Valuation: 14,430.00 Fire ProteC PRINKLERED Type Const: V`N Type Occ s 0016 OFFICE UBC Edition: 1991 Occupant LoadN /C Occupancy Grp:B -2 F7= Update, F2= Previous Line, ESC = Cancel Update CITY OF TUKWILA Id: ROUT130 Keyword: UACT User: 1677 12/01/92 Activity document routing maintenance. BUILDING PERMIT Permit No: B92 -0407 Route: 1 Current Route Line: 3 of 6 Packet Units Description Station Status Received Assigned Complete aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa Packet Units Action Station Initials Status Received Assigned Completed BUILD 01 01 C BLDG KEN Approved 11/16/92 12/01/92 12/01/92 Priority (0 /low..9 /high): 0 Regular hours HH.MM): .00 Overtime Hours HH.MM : Comments . 1 " SC OP ExOFti' }WO RK ,7x 1. DEMO SOME EXISTING WALLS. 2[' " " 2.CONSTRUCT NEW OFFICE PARTITONS. 3[ 3.WIDEN REST ROOM ACCESS. ] 4•[tEXIT r .. ..,,O.K; i ] 5'['QCC`LOAD ;`. f N/L ] 6[ 7 [FIR1 8 9 [ 10[ LEASE REVIELAN D:COMMENT. ] ] ] /r �W. INDEX OF DRAWU'JGS INCLUDE INSET r.,9 -/.- NO. _ 'SHEET T NO , DRAW I NG TITLE REV DATE DRAWING GENERAL 40 7- 35--AD AO COVER SHEET A 1.18.92 ARCHITECTURAL 7- 35 -IA10 IA1OR FLOOR PLAN (REMOVAL) _____. 11,18.92 7--35 I A 10 I A 10 FLOOR PLAN - _...__. , f I . 1 8.92 7•• -35 -2A 10 2A10 FLOOR PLAN IIJ8.92o. 7-- 35-- IA280R IA28OR REFLECTED CEILING PLAN (REMOVAL) 1!.18.92 7-- 35 -IA280 ._ IA280 .2A280 REFLECTED CEILING PLAN - LING 11.18,92 7 3 -2A28 Q REF I_E C ► ED 6 L I NG PLAN I f . 18.92 7-35-A500 A5U0 DETAILS 11 . 18.92 MECHANICAL .......... . 7 35 - - 1Mi0 _ ._ 1_MIf-, HVAC PLAN 1 I . 18.92 0 I 7-35-2M10 2M10 HVAC PLAN 1 I . 18.92 7 35 I M I I UR I M I I OR PLUMBING PLAN (REMOVAL) 2 7--35- I M 110 I M I f G PLUMBING PLAN 1 1.18.92_ ELECTR I CAL 7-- 35-1EI0 IE10 LIGHTING PLAN FIRST FLOOR < ' < < < 11.18.92 73� 2E10 2E10 LIGHTING PLAN SECOND FLOOR I ! 18.9 2 7-35-1E60 1E60 208Y/ 120V POWER FIRST FLOOR - 1 1_ 1 8.92 7-35-2E60 2E60 208Y/120V POWER SECOND FLOOR 11.18.92 0 1 0 " . 7-3 7-35-2E360 1E360 2E360 COMMUNICATIONS AN PL FIRST FLOOR COMMUNICATIONS PLAN SECOND FLOOR II. 18.92 1I 18 . 92 ._._. /r �W. .tPP r - D - 1U� ��r� � -t i DATE j . � a.92 r.,9 -/.- - RFV ., 4 BY PPPRCHED [DATE { i RVISKM CONSOLIDATE FOOD SERVICES #92060 PC L83[LALD11 1267 K IL PUGET SOUND REGION J t __ _- •' r ,- _ _�_._�_ _. ` FEDERAL. WAY . N N i / r / 1Y VICINITY MAP KENT 8 I ) AUBURN r ATE S GTON 9 16 1, E3E1.1 r1(i1 +: RFNTON / ` r ALGONA KING CO. TO TACOMA PIERCE CO. NO SCALE AY DRIVE BUILDING 7 -35 PROJECT SfTE rrr.....a.+ FACILITIES DEPARTMENT PROJECT LOCATION ice. -•.e1 hX SITE PLAN DIMAIASH MEM N\c \<1,4t a AUBURN, WA. 98002 0 BELLEVUE, WA. 98007 0 EVERETT, WA. 98201 0 KENT, WA. 98031 0 PORTLAND, OR. 97220 0 RENTON, . WA. 98055 SEATTLE, WA. .98124 ISSUE LEGEND NOT YET ISSUED PREVIOUSLY ISSUED, NOT I N THIS ISSUE N THIS ISSUE PREVIOUS PROJECT, NOT YET ISSUED FOR CURRENT PROJECT PREVIOUS PROJECT, NOT REQUIRED FOR CURRENT PROJECT NO SCALE P.,. X55°4 i REGiSTEREJ ' 4I�CFfI ACCEPTA on/ TNlS DEIGN MO /art SPECWICAT1oN IS APPROVED E'f R. APPROVED lrY 1 MPT. , w DATE CODE SUMMARY EXISTING ADDRESS PROJECT SUMMARY P. CARPENTER lefr Ap Th AF'PRO?VED 4 = .l �. `h �!', C y r✓ S�' ARCHITECTURAL MASTER j 111 I l I I I' I I J I J I I I I I � I J I I I I I � I I I I I1I P P I I T T H l 0 16 YHS INCH 1 2 lZ O 6l el LL 9L 5l +7l El Zl I j i f 1 ; 1 1 1 1 . 1 ! { ' I ' • , I j . 1111; (Litt (I 11111 is , IIIJ I 1' jl III I lI 11 Ii.' 3 4 5 _ 6 I 7 8 NOTE: I f the microfilmed document is less clear than this notice, it is due to the quality of the priginal document. IjIIIII111111IIII1III 1 1 1 1 1 1 1 1 1 01 1 1 1 1 1 1111111 9 10 11 HARE IN OF,RHANY 12 I I II� II i+ i o1_ 6 8 L 9 5 4 7 £ z l WW IIIII�! IIIIIIIItII IIIIIII�IIIIIIIII�I 'IIIIII�lll1 I I�ihIII IIIIIli1111111i1I1] L1I I I III J !j11!IIIII111111lII1I�I?IIIIIl �lllllll II!IIII11111I�1I I� 1111!11 II I I I �' I II II O ,..., I, .:. , .... L. I. III III . liI( III��III IIIIIIl II�II�LIlI )�IILn,i�lllil�ILI,1h!�1�111 �IIII�LII�IIIIIIIII�II1 11111! IIIIIIIIIi�lllillllilllllli !IIII�t1l 1267.4 GATEWAY DRIVE, B U I L D I N G 7-35 TUKWILA, WASHINGTON 98168 CODE . .1985 EXISTING CONSTRUCTION TYPE V' -N, FULLY SPRINKLERED EXISTING BUILDING AREA 97,800 SQUARE FEET (APPROX,) EXISTING OCCUPANCY GROUP 82 (OFFICE /WAREHOUSE) EXISTING FIRE PROTECTION FULLY AUTOMATIC SPRINKLER SYSTEM NEW IMPROVEMENTS (TENANT I MPROVEMENT5j ADDRESS 12674 GATEWAY DRIVE, BUILDING 7-35 TUKWILA, WASHINGTON 98168 BASE ZONING NO CHANGE CODE 1991 CONSTRUCTION TYPE. NO CHANGE TENANT AREA 26,101 SQ. FT, OCCUPANCY GROUP . NO CHANGE FIRE PROTECTION NO CHANCE SUB---DIVIDE APPROXIMATELY 800 SQUARE FEET OF_ EXISTING OPEN OFFICE INTO I N D I V I D U A L OFFICES. ENLARGE E X I S T I N G HALLWAY WIDTH AND TOILET ROOM DOORWAY CLEARANCES TO ALLOW DISABLED ACCESSAB l L I TY. CONVERT APPROXIMATELY 265 SO. FT, MAINTENANCE SHOP FLOOR TO OFFICE USE. REMODEL APPROXIMATELY 230 SOIJARE FEET OF INDIVIDUAL OFFICE INTO OPEN OFFICE. COVER SHEET COL 1 -4/B- H IL ww orsairi csa approvals are .. s that the P1an Check' app royal o{ understand issior5 and 'approval 1 unde and Orr+ the violation nd'ap o{ act t0 errors a rite o { cc sv'oi not authori � adopted does code or ordinance. sec t of con . adOPt of approve - ., 4 tr actor' G "i .�.. . , . a pate -- permit No C.P ? " �� SHEET SEPARATE PERMIT REQUIRED ptMECVIRNICAL ELEIC ►:'� PLUMBING Gas PIPING CITY OF TUKW110 E 0E1\103 2 MMO GO c oVie U ENGINEERS tiYl1BgL -r T ^- is�S SIGN 4 'i ? R j'? B UILDING 7-35 . ___w __ __-______��_..__,__... _w_ , OF 13SS -4-- 92060 92137 "IUKWILA DWG 14n• BSS.- 4.- .92061) 2APAOO 1 N PR : t4Y,, ✓-= : .,_!....h ....,.. .. ?,j ?, .::,:YS :.7.. _:. �✓'' x .',' �: :'�itnia:3' _ r '" . ia:F?.. . � �f:'c;Y✓�:'::�.�+.tt�° « I - REVISION BY _ _4141_ 50•...0 FLOOR PLAN! SCidE: 77 -0 � (2� 4 T I I 1 I II 50 0' 4141. ........... v.......0.. 0,. w,... FACILITIES DEPARTMENT 50' -O' o • AUBURN, WA. 98002 O BELLEVUE, WA. 98007 O EVERETT, WA. 98201 O KENT, WA. 98031 O PORTLAND, OR, 97220 O RENTON, WA. 98055 rti SEATTLE, WA. 98124 4141.. . _...._........ �.�..�.. .,<.. � r....: - �tSrc+� s .. f .P!. ^ti•3 ��.., 4141 ...� b �- � -..,,w �t+`+� ° : t nl%%t�jf Fy,'7.s3.a:' ; ��r'*� '� ' 4141... 4141 � t. 4141 ,�+ �...��Y���, (490 REGISTERET1 imfqii EC gTATE ` 1 WAS4stttaiImt �t- - - 4 ti C Ehs ACCEPTABILITY I P. CARPENTER ; This DESIGN AND/OR SPECIFICATION IS APPROVED APPR(Mf) 13Y A OVED suatitt __ — TfIE r�• • A; 7 41 ,41 I I I I I I I I I I I i 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ) 1 1 1 1 1 1 1 1 ' I � i lI I l ' I ' 1 1 1 lit ' Willi! " I ' 1 1 1 1 III I I ` I I I (° I I I I I . I I I I I I I Ititt I 8 0€ 6Z se GZ 9Z 5Z tt? ' CZ Z 111!1 {Illililll{ III ►11111 {IIllI! IilI II II Ii�ll 1111111 {IIIII III4LILIJIIIlllI _ ::..... _.... ..... .,....«._ NU ?Et It the microfilmed document is less clear than this notice, it is due to the quality of the original document. tZ OZ 6t 91 Lt 91 GI VI et Zt tt 01, 6 111 I Ili. 111 II�II IIIII�IIiI 'IIIIIIIIIIIIIIIIIIIIIIIIIII 9 10 11 /ODE LNGERMAHY 12 illii inil lii{ hi111111 I{ 11III!ii(1111111I11M11I11!{1111 1111111111111 1111 1111!111111111111llllll111111111111 11111 111!111 1111111 I II I II I II 11. 1II 1 E . '111 0 � :. 4141., ,4141., � .,.... 1 41,41: 41,41._ IL 1{ , „ 4141) } 111 �l I il l II IIIIIIII{ Ii IIIIIIiIlIIII1111111lIIIII1111111 .�. i. 4141 .:...� 4141.. 4141«.,:: l��`i,. , 4141 `� ., ,Y'is�.b�',? }Ak'ry�„. ., Jrf ✓r`r; �. i::. 4141. FLOOR PLAN ,_ ARCHITECTURAL. MASTER COL 1- 4/B.•_H 7 A f3 BUILDING 7 -35 LEGEND: END GENERAL NOTES: INDICATES REMOVE EXISTING SHEET VINYL FLOORING AND EDGING STRIPS CONSTRUCTION NOTES: REMOVE DOOR, HARDWARE & FRAME COMPLETE. RETURN DOOR AND HARDWARE TO BOEING SURPLUS AS DIRECTED BY BOEING CONSTRUCTION MANAGER. REMOVE DOOR, HARDWARE & FRAME COMPLETE 2 -- AND STORE ON—SITE AS DIRECTED BY BOEING CONSTRUCTION MANAGER FOR REINSTALLATION IN NEW WORK UNDER THIS CONTRACT. • REMOVE GYP. BD./FRAME PARTITION AND BASE. APPROX. 460 SQ. FT. THIS SHEET. REMOVE WINDOW & RETURN TO BOEING AS DIRECTED BY BOEING CONSTRUCTION MANAGER. TUKWILA t KEY PLAN SURPLUS Jos NO BSS- 4 -92060 ENGINEERS I,A.ST REVISION SI EET IA COMP NO. 92137 1 OWG NO. 7 - -35— 1A1 OR 2APAO1OR PR ► 1. 2; ' I (. 1 1 •27 . 9.S 4141. ^;.!'i�'q'°'r1�'}�.^.`�•�'..J +'.'��'�:�:�:�.. _ I? F � .........,,...._...._..��. �:` .,� ...:.ate ,!ri r, <ti� -T�.F ,. . -. 4141. �A�.�' FLOOR PLAN EIY AMMO _ ' LATE , SW CONSOLIDATE FOOD SERVICES #92060 PC WH LW I: t .18. 92 HALLWAY -=-- OPEN OFFICE STORAGE �o�= = x •_ IIIII1I1I1 IIIIIIIIIIIIIIIIIIIII MILLI I I1LI111I1I T!I .,I -: , II ,'L I4I IIt 11 I pi I I i t ° I :: r , I f itifilif 0 ,6 THS INCH 1 3 pi' 5 6 '7 8 ' ' NOTE: If the microfilmed document is less clear than this i - notice, it is due to the quality of the original document. i I DC 6Z ee LZ 9Z 9L ti ' CZ Z IZ Oz 6L 9t LL 9L SL bt £L ZI It 01, a I IIIIIIIIIIIIIIIIIIIII!II IIII I II! I►!! III1LIIIIIIIIII !!IIIIIIIIIIIIIiIIIUdrill 1114! II1III. ' IIII!IIIIIIIIII II ! ! . Ill1 11L1I1 IJIIILI. I.I!I�IL!I!I!IIIlI,I , I�Il III1IIIIIIIIIIIILIIIIIIIIIIIIII �' r r „ WA. 0 559 R C TTE ED 1_. OVA. 98 02 WA. 98201 WA. 98031 , OR. 97220 0 RENTON, WA. 98055 SEATTLE, WA ; 98124 JAY S. • WALLACE STATE OF WASHINGTON \< I q /ert. ACGEPTAIILITY Tits DES ON AIWOR SPEC,1F!CATION IS APPROVED APPRCNED aY DEPT 11 I III I I1I1I IIII I I I I I I I I I i 1 I 9 ! 10 I 11 mANINCIEMAMIY 12 L 9 S ' £ Z l ww O LIIII)I111►:If �III II IIIII! VIII) IIIII!l IIIIIIII11111IiIlllllil lllll!lIIIIII Y + 1"' �F..:f Y.v;�,q'�i� C•y,. Y. f ` , ," '� t IIIf I II I 22. APENTER 50'- WAREHOUSE 08 • .._ ..._.�..._. .r,.•_._■....OW 0 N •st- C'-' N G� w...w..w. •••••.w.... ww .gW..e+rMYOI 11. PROVIDE & INSTALL NEW MATCHING CARPETING WHERE INDICATED. COORDINATE EXACT CARPET INFORMATION W/ BOEING CONSTRUCTION MANAGER. PREPARE SUB -BASE PER CARPET MANUFACTURER'S 'RECOMMENDATIONS. MODIFY, EXISTING DOOR HARDWARE AS FOLLOWS: NEW LOCKSET: YALE 5407 FL NEW THRESHOLD: PEMKO 1714 NEW WEATHERSTRIPPING: PEMKO 58801 NEW ASTRAGAL: 1 1/2" x 10 go. ALUM. W./ S88D1 GASKETING 13. PROVIDE & . INSTALL NEW MATCHING 4" VINYL BASE AT ALL NEW PARTITIONS. MODIFY EXISTING PARTITION AS SHOWN ON DETAIL B, SHEET A -500. MODIFICATIONS ONLY IN AREA INDICATED ON PLAN. PROVIDE & INSTALL NEW GY. BD. PARTITION. SEE DETAIL B, SHEET A500. F PROVIDE & INSTALL NEW CYP. BD. PARTITION TO UNDERNEATH NEW SUSPENDED CEILING. SEE DETAIL 3 SIM. & 5 SIM., SHEET A500. PROVIDE & INSTALL MATCHING 4" COVE SHEET VINYL FLOORING & VINYL BASE TO ACCOMODATE RELOCATED PARTITION. PROVIDE & INSTALL NEW GYP. BD. PARTITION. SEE DETAIL A, SHEET A500. PATCH . EXISTING GYP. BD. 0 PLUMBING REMOVAL WORK. SEE MECHANICAL DINGS. FOR EXACT LOCATION. INFILL PARIItm0N AT REMOVED WINDOW WITH MATCHING GYP. BD. & STUD WALL RUSH WITH EXISTING, FINISH TO MATCH. ' OCCUPANT LOAD IS 28. • THEREFORE ONE (1)- EXIT REQUIRED, AND ONE EXIT IS PROVIDED. ALL NEW CYLINDER LOCKS TO RECEIVE ZERO BITTED CYLINDERS. THIS HALLWAY IS NOT A REQUIRED EXIT CORRIDOR AND : HAS NO FIRE RATING REQUIREMENTS. PATCH WALL FINISHES AT ALL REMOVED ELECTRICAL DEVICES. MATCH ADJACENT FINISHES. REINSTALL HALLWAY DOOR & FRAME STORED ON- SITE. PROVIDE ALL REQUIRED RE- FINISHING & TOUCH -UP FOR A COMPLETE FINISHED INSTALLATION. REMOVE UNICAN LOCK & INSTALL YALE 5401 FL PASSAGE LATCH. PER=lT CENTER FLOOR PLAN BUILDING 7 -35 RECEIVED CirY OF TUKWILA NOV 3 0 1992 YI : NEW GYP. BD. PARTITION ARCHITECTUR.AI. WASTER COL 1-4/8- H TUKWILA GENERAL. NOTES: KEY PLAN NEW DEMOUNTABLE PARTITION INDICATES NEW MATCHING CARPET - CONSTRUCTION NOTES: INFILL OPENING IN PARTITION WITH MATCHING GYP. BD. & STUD WALL FLUSH WITH EXISTING, FINISH TO MATCH, PROVIDE MATCHING BASE EACH SIDE. ( i ) (' (1 IAlO 4o. coo ,1o. , BSS -4 -92060 92137 tr " . ..� NC°. 7- 35 -- 1A -0 2APA0101 PRC/ 11.23.92 /11:07 : •.F Y/yy� ,x1 x� 1 . pp B &e ENGINEERS A 1'1 18.92 PROVIDE & INSTALL WALL MOUNTED STEEL SUPPORT W/ PLYWOOD DECK FOR MECHANICAL EQUIPMENT, SEE DETAIL 7, SHEET A500. ALIGN NEW PARTITION FLUSH W/ EXISTING PARTITION FINISH. . ALIGN NEW COLUMN FLUSH W/ EXISTING COLUMN FINISH. PROVIDE & INSTALL NEW 3' -0" x 7' -O' x 1 3/4" SOLID CORE OAK DOOR IN MATCHING PRE- FINISHED FRAME. DOOR FINISH: STAIN TO MATCH EXISTING: DOOR HARDWARE: LOCKSET: YALE 5407 FL HINGES: HAGER BB 1279 4 1/2 x 4 1/2 WALL STOP: BBW • W9X CLOSER: - YALE 4400 THRESHOLD PEMKO 1714 WEATHERSTRIPPING: PEMKO S88D1 PROVIDE & INSTALL NEW 3'--0" x 7' - -0' x '1 3/4" SOLID CORE OAK DOOR IN DEMOUNTABLE PARTITION FRAME. DOOR FINISH: STAIN TO MATCH EXISTING. DOOR HARDWARE: LOCKSET: YALE 5407 FL HINGES: HAGER BB 1279 4 1/2 x 4 1/2 WALL STOP BBW W9X PROVIDE & INSTALL NEW. 3'-G" x 7'-0" x 'I 3/4" SOLID CORE OAK DOOR IN MATCHING PRE - FINISHED FRAME. DOOR FINISH: STAIN TO MATCH EXISTING. DOOR HARDWARE: LOCKSET: YALE 5407 FL HINGES: HAGER BB 1279 4 1/2 x 4 1/2 WALL STOP: BBW W9X , CLOSER: YALE 4400 THRESHOLD: PEMKO 1714 WEATHERSTRIPPING PEMKO 38801 NOTE THIS IS NOT AN EXIT DOOR. PROVIDE & INSTALL DEMOUNTABLE PARTITION, SEE DETAILS 3 & 5, ON SHEET , A -500. SEE '.SHEET A- 500 FOR PAR Tf1ON SPECIFICATIONS: REINSTALL RESTROOM DOORS & FRAMES STORED ON -SITE. PROVIDE ALL REQUIRED RE-FINISHING . & TOUCH-UP FOR A COMPLETE FINISHED INSTALLATION. PROVIDE & INSTALL NEW GYP. BD. PARTITION FLUSH WI NORTH FACE OF EXISTING PARTITION. SEE DETAIL C, SHEET A -500_ MATCH FINISHES. . LAST REVISLOH SKET 3 :i'SW I� A CONSOLIDATE FOOD SERVICES , #92C160 f3Y APPROVED J DATE SIN JW WH LW 11.18.92 FLOOR PLAN RUISION OPEN TO WAREHOUSE BELOW ad !7t* >rs.•„ a� ::: •r;.v -... '"r.u' c. r *!".t -±-. ._ mmoy.^r ?°°3 r y..' ,yi 4 ` Yr�rr�`�^ ` ��. ,r.i ■••, ,...._. ...,.../MM..,,...,...ftlA....._.. ( /4 FACILITIES DEPARTMENT skl:`.'•' p�' F�^ GS' 1:" �?' ''�` k > . «�!na"1�'S';�;;f1+�.:¢�s - � �+• * y O AUBURN, WA. 9800.2 0 BELLEVUE, WA. 98007 O EVERETT . 9820 O KENT, WA. 98031 0 PORTLAND, OR. 97220 0 RENTON, WA. 98055 kATTIE,'A, X { ! n ; ACCEPTABILITY THIS tES1:1rr AND /OR SPECIFICATION IS APPROVED APPROVED BY DEI>'I.1 DATE 4 Iii_ P, CARPENTER T IIiIIIIIillip riiiIiliiiiiiiiliiiiiii,IiIIIi iiiiiiil [ II' r i iliiiii all ii 11111I1111111 ii I (irl P )5 III ICI 0 18 ?NS INCH 1 2 3 4 5 6 7 8 NOTE: .If the Microfilmed document is less clear than this notice, it is due to the quality of the document. zz Lz OZ el al Lt 9t S !! I t 4 71, CI ZL LL p f IU�Jlllllll 11111' �Il Ii11111111iI�1 1) UIII�Jllilililll! Ii�IIIIIIIIIfIIIIj1Llllil !IIII!ll,i�lllllii 1111!1!1IIII v < r atlj' f : MADE IN GERMANY c z I WW 1!!11111! i111111111111111111�i11111 !;IIIIil11111� ARCHITECTURAL MASTER COL 1-- 4 /B--H FLOOR PLAN BUILDING 7 -35 ._ _._..._._. " ... -.. _._... _o..._._ LEGEND: GENERAL NOTES: CONSTRUCTION NG REMOVE PARTITION, PATCH ADJACENT FINISHES AS REQUIRED AT REMOVAL. PROVIDE & INSTALL NEW MATCHING CARPET AT PARTITION REMOVAL. REMOVE DOOR, FRAME & HARDWARE COMPLETE. RE1URN TO BOEING SURPLUS AS DIRECTED BY BOEING CONSTRUCTION MANAGER. KEY PLAN SCALE: NONE TUKWILA 6 . ' 2APAO102 ....� ,�. X�...i.J+�7 �....« _..,.': +T"� `r}''�.��9"�q�I< A'y .�.�' _' a Y �'•."2' � .��y yam,+ . .tr: 1.,:+..� - n�.t 1�, v'. r' r.. �' i�. w 'a[anWtr.:L4LYii�,traT:ri•�'-�1 st ....rt,� +r. BE &C ENGINEERS �i DATE 171ST r�ttisIoN A 11.18.92 SHEET 2 JOB NO. CC,f,� NO 2 BSS- 1 4- 0 92060 921 37 MO NO. 1-35 2A10 PR 11 T.6 . � 1 / 1.0 .3" -otio or BY - _ _ __ L ......_ '!"‘PROVED DATE SYM I _ REVISION BY APPROVED DATE ......,________ — — _ ._ _ ._........4 _ _. _.............4.........___ ..„........_ _ _______ • — — — SYM ••••■•••■Nromarwor RNSIDN ""!.. •-••"' : erls-/,- 50' - 0" 1 1'--O 4 .4 REFLECTED CEILING PLAN •••40. 4 (2) 50'-0" r1.41.0",■•••••■• *W. AffiraWintar FACILITIES DEPARTMENT r r .fr• 11111 till 1111 11111 0 1 I6 THS INCH 2 3 4 5 6 7 8 NOTE: if the microfilmed document is 1;,ss clear than this • • — O AUBURN, WA. 98002 O BELLEVUE, WA. 98007 O EVERETT, WA. 98201 O KENT, WA. 98031 0 PORTLAND, OR. 97220 O RENTON, WA. 98055 • SEATTLE, WA, 98124 notice, it is due to the quality of the original document. Ian ogoaohmae........orwasitlt- EG SITRE:0 . , , B ) F E ) ••■••■•• ■••14/•■■*•••,r ACCEPTABIUTY P. WPENTER SPECIFICATION IS PPRCIVED APPROVED eV birt. THIS DESIGN AND/OR 9 10 11 " NINANY 12 • 08 6Z 8 L3 9Z GZ t' CZ ZZ tZ OZ 6l et /..1 9l Gt fit Et L t hi I 1, I I !!! 11,1 LI 1 1111,11,111 0114 i(j11,191,1111111 I 111 01 JP ill.P11 1111,1!1!),I1 11A1 11! 11 1 - , . OL c z 0 • • • y 4. • 1 • • AVM --- WggitY 1 IIRE itetiliMONNSIEMOTSv REFLECTED CEIING PLAN ARCHITECTURAL MASTER • "I • COL 1-4/B BUILDING 7-35 LEGEND:. 7/ 74////,/ i// • GENERAL NOTES: CONSTRUCTION NOTES: i ,------, ( 4 ..! i 6) , •, ,, Y1 .., ---,--- --, , , ' / / ' ' / / / / / „. • . / / / INDICATES CEILING REMOVAL APEA REMOVE SUSPENDED ACOUSTICAL CEILING IN SHADED AREA TO ACCOMOFATE NEW PARTITION LAYOUT. t ti '6?- KEY PLAN orN Sffiff: NONE \jh 10 4 7 319 p. L AST R Sfirrt - • — . 1A28OR cOMP 408 hr, BSS-4-92060 I 92137 BEittc ENGINEER3 syOttcC -- 11)7kft 'TUKWILA DWG NCI 7-35-1A280R 2APA)AOR PRC/11.19.92/16: 1 3 I 4 I , ti _ _...._ _. _._. _ ._..._■ -- - -� .... • _ . •■... _. 4 50' _ 0." REIISION BY CONSOLIDATE FOOD SERVICES #92060 LPC JW j wH LW 11 .18.92 •— s =awe �. s*^s �s a?tirri cc a r tom* L r!�" -�..,, -.� -z.r REFLECTED CEILING PLAN (2) 50' —0" FACILITIES DEPARTMENT .c.� + - w w #,..,...�e.- i,Ye`.'"++, era,,, a- wu�,. rs„' 2 Kw± v+ h& ti-.+ tia�z .:= *= '�?'..;.z.:.'nlgri!ryw► Fir#• J+? 1.\ rF,' tnjd !^t.�}?%F1i�..+J+`,,^.`'43?P'W, i`: �,x,p��.?�s�+'°^o`CUif+�i _.Ttr""r..._ _._ _ �_ • 50'-0 _. O AUBURN, WA. 98002 l BELLEVUE, WA: 98007 O EVERETf , WA. 98201 O KENT, WA. 98031 O PORTLAND, OR. 97220 O RENTON, WA. 98055 SEATTLE, WA. 98124 ! ., 0 1),r t � L I _ / i) k �i ? �V1 I .•.� Y .as #I; ihtg Q 'VA:3-j.'i ,;1r} . 'lrr �0y� wb . ' 4 ACCEPTABILITY P t CA' 1HIS DX;$hN AND /OR SPECIFICATION IS APPROVED j am • APPROVED PY DEPT.1 DATE --( D A 10. PNTER 9. — RELOCATE FIRE SPRINKLER HEAD AS INSTALL NEW MECHANICAL DIFFUSER INTO EXISTING GYP. BD. CEILING. PROVIDE NECESSARY BLOCKING ABOVE CEILING. SEE MECHANICAL. DRAWINGS FOR EXACT SIZES AND LOCATIONS. NEW FIRE SPRINKLER HEAD. SEE MECHANICAL DRAWINGS FOR EXACT LOCATION. INDICATED. SEE MECHANICAL DRAWINGS. MECHANICAL SUPPLY AND RETURN DIFFUSERS ARE SHOWN IN NEW REQUIRED LOCATIONS. SEE MECHANICAL DRAWINGS FOR NEW & /OR RELOCATED ITEMS. U TITLE TITLE ARCHITECTURAL MASTER Q . IIIIIIIII111I111IIIIIIIIIIIIII {I rr•1� 1 111111� IIII111 IIIII { ", I(Ii I111 lilt 1JI - 1 {II Iii 111 I Il 11 0 te 1HSINCH 1 3 4 J r7 NOTE: If the nticrofilmsed document is less clear notice, it is due to the quality of the original 11111111111 1111111 11 UA ENGERWWY 12 0 LZ I OZ 6L 91 LL 9: 9I 4 71 EL ZL LL 101, E Z L rvw Q 11., 1�Ji�I�IIIIIIIIIi�I�I�In�Ii !I��!I!�I�niIJ�- . . - . . III► II�Illi1111 !InI11!!I!IIIIIIiii��III HAM" iii! hiliil !IIIIIIIiillii!!{n1111i111 - r t. COL 1--4/B H (> PROVIDE SUSPENDED ACOUSTICAL CEILING SYSTEM TO MATCH EXISTING. CONNECT AND ALIGN WITH CEILING IN HALLWAY, MATCH TILE PATTERN. p>. REFLECTED CEILING PLAN BUILDING 7-35 LEGEND: 77 iY /1 GENERAL NOTES: INDICATES NEW SUSPENDED ACOUSTICAL CEILING, SEE CONST RULTION NOTES ALL SUSPENDED ACOUSTICAL CEILING WORK TO CONFORM TO DETAILS 1, 2, 4 & 6, ON SHEET A500. 2. PATCH EXISTING CEILING FINISHES AS REQUIRED WHERE WORK UNDER THIS CONTRACT DAMAGES EXISTING FINISHES. CONSTRUCTION NOTES: PROVIDE SUSPENDED ACOUSTICAL CEILING SYSTEM. SUSPENSION SYSTEM: MATCH EXISTING OFFICES, ACOUSTICAL TILE: MATCH EXISTING OFFICES PATCH GYP. PD. CEILING AT RELOCATED PARTITION W/ 'I /2" GYP. BD., FINISH TO MATCH EXISTING GYP. END. CEILING. MECHANICAL AIR HANDLING UNIT (SEE MECHANICAL DRAWINGS) TO BE INSTALLED ON TOP OF EXISTING CEILING FRAMING (4" x 25 GA JOISTS). PROVIDE & INSTALL 3/4" PLYWOOD DECKING FASTENED TO MINIMUM THREE (3) JOISTS W/ /18 SELF — TAPPING SCREWS la 1 2' Q.C. SECURE AIR HANDLING UNIT TO DECKING. LOCATE DECK & UNIT AT NORTH WALL OF EXISTING OFFICE. RELOCATE EXISTING FLUORESCENT LEGHTTNG FIXTURE AS INDICATED. RELOCATE CEILING TILES AS REQUIRED FORA COMPLETE FINISHED CEILING INSTALLATION. REPLACE ALL TILES DAMAGED IN THE COURSE OF THIS WORK. SEE ELECTRICAL DRAWINGS FOR LIGHTING. NEW 2 X 2 FLUORESCENT LIGHT FIXTURE. PROVIDE NEW SUSPENSION FRAMING MEMBER. SEE ELECTRICAL DRAWINGS FOR LIGHTING. / // / r/ /r / . ,r' r r r/ KEY PLAN Tr VN TUKWILA •Lk ,!a yLl ( j: I ' 2 P. '`) \1 r f `;s i' l's . J Nt?. 7-35— A280 BE &C ENGINEERS 11.18.92 { 7APA2' ' 1 P 2 R C 1.19, 9 1 . r 4. V r ---- RE!nson hA CONSOLIDATE FOOD SERVICES #92060 aese !Y' APPROVED PC ,JW WH LW IVLSIN I SCALE: 178 1 o REVISION (?) REFLECTED CEILING PLAN FACILITIES DEPARTMENT 0 AUBURN, WA. 98002 £ 3ELLEVUE, WA. 98007 0 EVERETT, WA. 98201 0 KENT, WA. 98031 0 PORT'L_AND, OR. 97220 0 RENTON, WA. 98055 I SEATTLE, WA. 98124 orfarlpr DAV SUIFO TLE -. ,� ACCEPTABILITY P CA PENTER REGISTER/1) F REIN ,., tr � T JAI' a WILLIAM ,TAlt PF h'A$N1fici.tti jo , y � '. " vE± b 'G}tA'A= °,Y t'°•'a,F'��► '!'w•y tea . �"`'+ �' . i • = V� ,.,,.d..F�.i�.� i u�.r `�".1+`F•�` x3M7' „ �ldY±�^�"��l'1'�:�A�+S! sM .sw. - - ... .. � � .., ... t ��•3'�'".T' +3*rY�f' #�''fJ^�°�3�r+ ^".,1'?"` "_' ?1 ''°' '^ + //f HI\ .,) ?HS DESIGN AND/OR SPECIfo11ON tS APPROVED APPROVED W.( 7 4 '. E I CR. OAT!_ ► --.- rnrarD MI I III�I I I I I I I�I I I I I IIIJIIiIII�IIIIIII IIIIIIII I I I III�IIi�i I lIj IIIItIIIIiiIi I l. I I , i I I Ii I i I 1' I II III II;) : 11II Q 14 THS INCN 1 2 .:. 4 5 6 7 O r NOTE: If this Microfiloaed docum is less clear than this ! notice, it is due to the quality of the original document. I II I III 4 IIIIIII I IIIIIIIIIIIIII1I1IIII111111III1li111 I 9 ? 10 11 MAC" OERMhw 12 0€ 6Z 8G L 9Z 5 +!Z , EL ZZ !z Q? 6L 8L Ll 91 ' I t4 £ ZL 11 01 6 f3 L Z ! wv+ Q IIi11l 1111{ 111 {i11111I111111{1111111111111. 111111 illlll lllli l ll�111IIIIIIIIIIIIIIIIIIIIIIIII IiIiii1.111�11111i11111111 I1{III11111 111111!111111l� 1111Ii11111111{ I I I I " 1 .. :. >... :.. ,.. ., , . ,,:,. .,.. 1, .:. ,.. .. .L: � .. a.._.. .:._ _III�II11,111(I (IIIIII! VIII) 11, IIIIIIIIIIII Ii�111111i111 111111II111�Inililiillllllllllllllll • , ._.:; Week TrrLE ARCHITECTURAL MASTER REFLECTED CEILING PLAN BUILDING 7 -35 LEGEND: GENERAL NOTES: CONSTRUCTION NOTES: I REPLACE CEILING TILES WHERE PARTITION REMOVAL. WORK DAMAGES OR DISCLOSES DAMAGED TILES. MATCH EXISTING TILES. 2. PROVIDE MATCHING CEILING TILES AT RELOCATED MECHANICAL DIFFUSERS & /OR FIRE SPRINKLER WORK. [ :> REMOVED PARTITION & DOOR BELOW. SEE SHEET 2A10. 4. MECHANICAL SUPPLY AND RETURN DIFFUSERS ARE SHOWN IN NEW REQUIRED LOCATIONS. SEE MECHANICAL DRAWINGS FOR NEW & /OR RELOCATED ITEMS. 5. NO FIRE SPRINKLER WORK ON THIS FLOOR. i / F / ; '�.'/ / ' ; %/. KEY PLAN SCr NONNE SHEET 2 Joe N(%. ,. l!{ U' t i , INF o \\ a 121 ENGINEERS t3L " tl'sr r:tv!SIOI A 11.18.92 (;OIMMP NO. BSS-4--- 92060 92137 DWG NO. " 7__35-2A28O COL 1-- 4 /B - -H TUKWILA . �. 2APA2802 PRC 1 I .18.92/12:55 :d a_.;w :'„' wX_l..�S.S. •- � - - -. ' S , ,1,� 1. ,fi•rr: c.,�. r f .. _.c... .f .�. -.. - • ., .: .,. �.� <.,..rL'a; •..,r,...t..,:: . ,_- ...:,:..c � "�� ,w_<;� ..� ].X: ' i`�.�hln�y � 'l ' ?"`iS`5 "`.. .._ >. �.., .. i Ix:.uG't -.sS,a .. ,..d �.r�.y...4�. -i} >}+✓ a ....: i+T..3.' ...> c'_ r I x ----- .- ........_ ....._._ ............. _ - ..— .111LU LU1illli ULU11U.1,i,. a 3 4 �. LIGHT FIXTURE ..-- -. ATTACHED TO SUSPENDED CEILING SYSTEM W/ (2) CLIPS OR (2) SELF TAPPING S.M.S., ONE AT EACH END NO SCALE 4 r fv NEW LAY-1N SUSPENDED CEILING SYSTEM @ 8' -6" A.F.F. --- ......"- G / 4 PROVIDE SOLID 2X BLOCKING, TYP, ---''� NEW PARTITION: 3 5 /8" x 25 GA. MTL. STUDS Q 24" O.C. W/ 5/8" GYP.BD. EA. FIDE CONT. MTL, TRACK W/ PONDER DRIVEN ANCHORS @ 24' 0.0 --° --` MAINTENANCE ofto __.__- -.�.._ ......_- .- - ...w._. 4CKW s .1 Uixiiilw.U.w.luunnhiuAluuiiutuu tWAtxu n C " � REV S CONSOLIDATE FOOD SERVICES #92060 PCJW LIGHT FIXTURE BRACJN(JYFI ) _ I _ i A2801 DEMOUNTABLE PARTITION SYSTEM AS SPECIFIED FASTEN RUNNER TRACK WITH 1/4" D I A POWER ACTUATED FASTENERS @ 24" U.C. VINYL BASE TO MATCH EXISTING / EXIST. CARPETING OVER CONC. SLAB NOTE: PARTITION TO BE INSTALLED OVER EXISTING CARPETING DEMOUNTABLE PARTITION BASS SCALE: NONE OFE' 1 CE OFFICES WAPEHOLJSE 3/4- - l'-0" APPRfNM MATE WH LW 11.18.92 4500 12 GA: HANGER WIRES, TYP. A50014500 l r s\ S I M \ \ (15 45500 A500 f- R--19 FIBERGLAS BATT INSUL. (FOIL. FACED) SIM _TO? OE - _PARTITION _ - EXTEND EXISTING PARTITION W/ MATCHING MTL. FRAMING & GYP. BD. 8 7 0" 70P_Q _EXIST• PARTITION_ PROVIDE R--1 1 " FIBERGLAS BATT INSUL. (UNFACED) IN WALL CAVITIES +r" INSUL. TO EXTEND TO TOP OF 1 PARTITION REMOVE EXISTING GYP. BD. THIS FACE ONLY & INSTALL NEW 5/8" GYP. BD. AS SHOWN WAREHOUSE ofte I A I O jA500 12 GA. VERTICAL-- HANGER WIRE (EXISTING) 5. 45' %.t W 8" MAX. CLEAR ----- PROVIDE CLEARANCE AT OPPOSITE WALLS, (NOT ATTACHED). ATTACHED AT STARTING AND ONE ADJACENT WALL, CEILINGGRID @ WALLS (IYELL_IM NO SCALE IA280 A500 MAIN TEE 45 ' f 1 � CROSS TEE .- `' % ,J C 4 144, WAREHOUSE #12 GA. HANGER WIRE, TYP. 3 TURNS, MINIMUM 8" MAX. LOCATE VERTICAL COMPRESSION POSTS PER DETAIL 7 I A280[A500 AT 12'-0" 0.C. EACH WAY, LOCATED 4'--0" MAX. FROM PERIMETER WALL INSTALL 1-5/8" S.S. 20 GA. "STEELER STUD OR EQUAL INSTALL WITH SHEET METAL SCREW TO CEILING AND WOOD SCREW TO STRUCTURE ABOVE USE #I2 GA. SPLAY WIRE BRACING IN PLANE OF FACH TEE. VERTICAL ANGLE, 45'. MINIMUM 3 TIGHT TURNS AT EACH END, NO BENDS OR KINKS ON WIRES. SEISMICALLY BRACE ALL OBJECTS WITHIN 6" OF SEISMIC WIRES. 45' NOTE: HANGER WIRES "E" AND '`W'" ARE IN THE SAME VERTICAL PLANE AS THE MAIN TEE. HANGER WIRES "N" AND "S" ARE IN VERTICAL PLANES PERPENDICULAR TO THE MAIN TEE. CEILING BRACE ( . IYP ICALI NO SCALE E • FACILI DEPARTMENT IA280 A500 EXISTING 2x & GWB PARTITION, REMOVE HORIZONTAL GWB FOR NEW PARITITION NEW SUSPENDED LAY...IN CEILING MATCH HEIGHT OF ORIGINAL CEILING SYSTEM -- EXISTING CONC. SLAB, SEE FLOOR PLAN FOR FLOOR FINISH NOTES PARTITION @ WAREHOUSE 3/4- v l'-o- ft , _ „Am-- --- ------ ._-- •----- ---- ------ -- NEW PARTITION: 3 5/8" x 25 GA. MTL. STUDS 24" O.C. W/ 5 /8" GWB EA. SIDE (FLUSH FINISH @ WAREHOUSE) f --r .— . -------- ---- -. 3 1/4" FIBERGLASS BATT 1NSUL. HALLWAY . �__ - -- CONT. MT TRACK W/ POWDER DRIVEN - .- ANCHORS 0 24" O.C. P BRACE SCALE: i 1 /2 OFF ICE O AUE:3UR.N, WA. 98002 O BELLEVIJE, WA. 98007 O EVERETT, WA. 98201 O KENT, WA. 98031 O PORTLAND, OR. 97220 O RENTON, WA. 98055 SEATTLE, WA. 98124 rv'? fS,. s, �3C. 6 !. riG�1 4i� rybYy�! CJNy/,} r ' 1 t 1 Sw . � r. Y"."_. i_ '.' �.. d' �. � G . rST:, �'!!.§ af' f% ro.. 9lt�i• F3�fyw' '. �i1'!'7,�',,�' r, .1' ... _..._.... ...- .- ...... _.... _...._._.... ....�- _.a_....._... _ _.2 __ . _ _ .. 1' BRACE 3/4" 0 RIGID METAL CONDUIT AS SHOWN OR 25.GA . STEEL STUDS (ALTERNATIVE) ALTERNATE (180') DIRECTION EVERY OTHER BRACE, FLATTEN END AND BEND, SCREW TO TOP TRACK OF PARTITION W/ SELF TAPPING SHEET METALSCREW, SCREW OTHER END TO UNDERSIDE OF FLOOR FRAMING 3 s iM A5()OLA500 HALLWAY HALLWAY PAR�r # T I ON 3/4- -- I ' .4) " t • -, SPACE BRACE Al 5'-6" O.C, ALTERNATE DIRECTION (180') EVERY BRACE - _ S i t0 i , . 411z1? S. W 4j I.A , • t.1L ';•iF t1• ,s:11.. ' NOTCH CEILING TILE AS REQUIRED A500 NEW OR E X I S T I N G SUSPENDED CEILING SYSTEM �---- NEW 6" MTL. FRAMING �.�-r- ~EXISTING 2x CEILING FRAMING & 5/8" GWB NEW 5/8" GWB CEILING INFILL `~ -- -2x SOLID BLOCKING AT CEILING LEVEL ---- . - -NEW PARTITION: 3 5/8" x 25 GA. MTL. STUDS @ 24" O.C. W/ 5/8" GWB EA. SIDE (SEE PLAN FOR LOCATIONS) MEN'S /WOMEN'S CONT. MTL. TRACK W/ POWDER DRIVEN ANCHORS 0 32" O.C. `'- EXISTING CONC. SLAB, SEE FLOOR PLAN FOR FLOOR FINISH NOTES MECHANJCAL PLATFORM SCALE: 1/2 ACCEPTABILITY THIS DESKA AND /OR SP CIFICOON IS' PPRRONED EXISTING CONC.. PANEL 3/4" C- -L) PLYWOOD DECK, ANCHOR TO FRAME W/ #8 SELF - TAPPING SCREWS 3 t r kOVED 1/2" DIA. EXP. BOLTS, 3 1/2" EMBED FI. CARPENTER_ SEE MECHANICAL DWGS. FOR MOUNTING HEIGHT 4 , -0 " � MAX 0 0 L_ 2x2x 1 /4 CROSS FRAME WELD TO FRAME ENDS L 1 x2x 1 /4 WELDED FRAME, ONE EACH END (SPACE END FRAMES 24T" APART) 111Ij111I11II1111 '11I11 0 14THSINCH 1 2 OC CZ 8e LZ 9 SZ +iZ ' CZ Z 1111E 11111111111 iii 111IIIIIi11111I1I11i111111l111111111111i1 ,1Y1111111 IIIII+Ii1I11 liliIItIIIlip r i 11 II1IlIml1I1 i III I I I 1 I 1 I IIi1 ill II 1 X111 1 3 4 5 6 7 8 MOTE: If the microfilmed document is less clear than this notice, it is due to the quality of the original document. tZ 0 61. Si Lt 9t St ttt CI Et tt 01, 411111 l 11111llililll1111llIIilotIIEIIUi1! 1l( lulu!!!nillUIIiI1I1111I HI11111111mlI Imiti 8 L 9 S - C t "IN 0 1111h11l lll�IIIIII�III�IIIllilil�lliil{l Ll�Illlilil( �I�I111�1111IIIli1I1 llllli�llllll� 0 o cre/ 0 0 0 0 12' -0" ON CENTER >� o d DETAILS BUILDING 7 -35 0 0 0 CEILING STRUT LAYOUT - #i2 WIRE PERIMETER HANGERS, 8" MAX FROM WALLS #12 WIRE HANGERS @ 4' -0" O.C. EACHWAY SUSPENDED FROM STRUCTURE ABOVE, CEILING BRACING AT 12'-0 » x12' --0" O.C. (MAX) TO MATCH STRUCTURAL SYSTEM AND ON CENTER, EACH WAY. SEE TYPICAL CEILING BRACING THIS SHEET. LOCATE FIRST POINT OF BRACING WITHIN 4'-0" OF WALLS. (OMIT WHERE ROOM IS 128 SQUARE FEET OR LESS) TYP SCALE: NONE (SEISMIC POD LOCATIONS) DEMOUNTABLE P A R T I T I O N S GENERAL: I. COMPLETED INSTALLATION TO BE.FREE FROM EXPOSED FASTENERS. 2. SOUND TRANSMISSION CLASS (STC) OF 36 M I N I M U M , I N ACCORDANCE W I T H ASTM E90. 3. DONN HIGH PERFORMANCE WALL SYSTEM AS MANUFACTURED BY USG INTERIORS, INC. TELEPHONE: (206) 646 -4900 PANELS: I. BEVELLED EDGE 5/8" GYPSUM WALLBOARD PREDECORATED IN MANUFACTURER'S STANDARD VINYL WALLCOVERINGS TO MATCH EXISTING VINYL WALLCOVERINCS. 2. EACH PANEL TO BE INDEPENDENTLY REMOVABLE. FRAMING MEMBERS: i, TREAT CONCEALER STEEL FASTENERS AND CLIPS TO PREVENT CORROSION. 2. DO NOT USE EXPOSED FASTENERS EXCEPT AT CORNERS, DOOR FRAMES OR END CONDITIONS. HOLD VERTICAL MEMBERS IN PLACE WITH CEILING AND FLOOR TRACKS TO PREVENT LATERAL MOVEMENT. USE CEILING TRACK TO COVER PANELS, 4. PUNCH STUDS AT 6" CENTERS FOR UTILITY PASSAGE. 5. STEEL FRAMING TO BE 2" WIDE 'HP' STYLE. 6. FURNISH & INSTALL THROUGH -POSTS TO CEILING OR OTHER CONCEALED SUPPORTS TO ENSURE LATERAL STABILITY PARTITIONS. BASE & TRIM 1. TO MATCH EXISTING FIELD APPLIED BASE. 2, TRIM TO MATCH EXISTING. PROVIDE TRIM REQUIRED FOR A COMPLETE FINISHED INSTALLATION , ELECTRICAL I. PROVIDE SPACE FOR VERTICAL RACEWAYS AS REQUIRED. SHEET LAST REv:skON A50O IA280 A500 ENGINEERS ciAtt 11.18 :92 JOk3 No, 65WR R0. BSS-4-92060 92137 ARCHITECTURAL MASTER COL 1.4 /B -H TUKWILA (Awc ice. 7-35-A50 0D i(� I '11.19.92/ A r . 5 .., P I� CG 2 ., tc�";s` "",.-,r`.. :e�T,'T "y c ? .. $.... f x �. ». w' .5..�... s -.; `«'` .+.r, ..`'�"..,��: "�.° ..a. � '" ' .�i ✓a .� ir, t -444