Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit 6523 - Boeing #7-383 - Temporary Trailer
I t 3 g3) sp* CoSa - a.,, Boeing .•e, 544 -2898 \DDRESS P.O. Box 3707, )K S 46 -25, Seattle, WA IaP 98124 - 1234 :ONTRACTOR Evergreen Mobile Co. PHONE 392 ADDRESS P.O. Box 1043, Issaquah, WA ZaP 98027 VA. ST. CONTRACTOR'S LICENSE 1$ EVERGM202KT EXP DATE 3/31/91 ARCHITECT Ever Mobile Co. PHONE 392 -1231 1 D DRE SS P.O. Box 1043, Issa.uah, WA aP 98027 'YPE OF CONST.: V - year 1988 SETBACKS: N S - E- W- =1REPROTECTION: O Sprinklers 0 Detectors O N/A UTILITY PERMITS REQUIRED? O Yes (fit) No p d workel '.ONING: ONDIT •N (other than those noted on or attac ad to perm Uplans) BAR/LAND USE CONDITIONS? O Yes III No i ,PPROV FO 9 'i .___� BUILDING 3SUANCE BY: 2 r� - ,.. ` /) A. ' _,, OFFICIAL DATE: _ . 3 -.,2 `c ° (/ / YTY OF TUKWILA )ept. of Community Development - Building Division 300 Southcenter Boulevard, Tukwila WA 98188 ?06) 431 -3670 3UILDING 'ERMIT NO. ATE ISSUED: (c7 5 Q 1 -1-- cti INFORMATION ;ITE A 'SE ,00R SQUARE OCC. OTAL 3IGNATURE: FEET LOAD 9800 'ROJECT NAME/TENANT Boein TYPE OF [xJ New Building WORK: 0 Rack Storage 0 )ESCRIBE WORK TO BE DONE: 1i7 - 383 ASSESSOR ACCOUNT #000340 -0018 Addition U Tenant Improvement (commercial) U Demolition (building) U Grading/Fill Reroof 0 Remodel (residential) 0 Other: TEMPORARY STRUCTURE - PERMIT EXPIRES 18 MONTHS FROM DATE OF ISSUANCE. Install 12' X 42' office trailer on concrete surface (Commercial Coach). E Marginal W SQUARE OCC. FEET LOeD SQUARE FEET OCC. LOAD I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of lav and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. ®`Jfl6..limii1W1 iiiv11111 (POST WITH INSPEt.. SON CARD AND PLANS iN A CONSPICUOUS LOCATION) FEES RCPT :QA > : MO Nr; 6�i A'd7IOW0 DESCRIPTIO < >? BUILDING: PERMIT FEE i:I PLAN: CH ><; BUILDING SURCHAR OTHER:. Inv st ` } atiott TOTAL': =: PLAN CHECK NO.: 90 -070 SUIT # SQUARE FEET OCC. LOAD 3 RINT NAME: This permit shall become null and void if the work is not comment issuance, or if the work is suspended or abandoned for a period o �ERTiFICATI:OF r.�. _...� ( DATE ISSUED: DCCUPANCY NO: ..._ .. N ...... 4 7 : A. I . 0 CO S RUO - 3,044.00 SQUARE FEET DATE: OCC. L 3• TOTAL with . days from t c 0 days from the:last l MI C, ,P ERMIT NO. CONTACTED G ar+h DATE READY DATE NOTIFIED _ q 1 ( It , cD - Q 5_ - PERMIT EXPIRES 2nd NOTIFICATION (iiy , tic . ) , �'ci I ( t i - AMOUNT OWING . G 3RD NOTIFICATION - bat Yi'ZP. f BY: u- L O--cI I (ini __,,, . PLAN CHECK NUMBER ' 0 ) t gib. BUILDING PERMIT APPLICATION TRACKING PROJECT NAME - Boefknj BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) - 7 - 3%3 SITE ADDRESS 9VXJ C YnOa' illUd DEPARTMENTAL REVIEW "X" In box Indicates which departments need to review the project. SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". SQUARE OCC. SQUARE OCC. SQUARE OCC. SQUARE OCC. SQUARE OCC. FEET LOAD FEET LOAD FEET LOAD FEET LOAD FEET LOAD TOTAL OCCU- PANCY LOAD TOTAL SQUARE FEET BUILDING - initial review 21 FIRE PLANNING O OTHER .BUILDING - final review INIT: UIREME ZONING: BAR/LAND USE CONDITIONS? Luso No REFERENCE FILE NOS.: MINIMUM SETBACKS: N- UTILITY PERMITS REQUIRED? PUBLIC WORKS LETTER DATED: Detectors ... .. ............................. • DE> A R.T I : 12) PUBLIC WORKS REVIEW COMPLETED .;f U FIRE DEPT. LETTER DATED: INSPECTOR: • I/ I VN t INIT: 2 - ;;;/ TYPE OF CONSTRUCTION: UBC EDITION ear): 16158 SITE ADDRESS SUITE # 9800 East Marginal Way S., Bldg. 7 -383 VALUE OF CONSTRUCTION - $ 31 OIL(' cc) PROJECT NAME/TENANT Boeing Commercial Airplanes /AFL ASSESSOR ACCOUNT # 000340 -0018 TYPE OF 1 New Building Li Addition Li Tenant Improvement (commercial) • Demolition (building) WORK: ❑ Rack Storage ❑ Reroof ❑ Remodel (residential) ❑ Other DESCRIBE WORK TO BE DONE: Install 12' x 42' Office Trailer on concrete surface (Commercial Coach) BUILDING USE (office, warehouse, etc.) Office NATURE OF BUSINESS: Boeing Military /Aircraft Component Testing WILL THERE BE A CHANGE IN USE? (J No Li Yes IF YES, EXPLAIN: SQUARE FOOTAGE - Building: 504 SF total Tenant Space: same Area of Construction: same WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? ® No ❑ Yes IF YES, EXPLAIN: PROPERTY OWNER Boeing Commercial Airplanes PHONE 544 -2898 ADDRESS P.O. Box 3707 M/S 46 -25, Seattle, tV\ ZIP 98124 CONTRACTOR Evergreen Mobile Co. PHONE 392-1231 ADDRESS P.O. Box 1043, Issaquah, WA ZIP 98027 WA. ST. CONTRACTOR'S LICENSE # EVERGM202KT EXP. DATE 3/31/90 ARCHITECT Evergreen Mobile Co. PHONE 392 -1231 ADDRESS P.O. Box 1043, Issa uah ZIP 98027 CITY OF TUKWILA Department of Community Development - Building Division 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 433 -1849 APPLICATION MUST BE FILLED OUT COMPLETELY CONTACT PERSON DATE APPLICATION ACCEPTED 9'01- C10 BUILDIIK3 PERMIT APPLICATION Garth L. Wilson DESCRIPTION BUILDING PERMIT FEE PLAN CHECK FEE BUILDING SURCHARGE ENERGYSURCHARGEE. : FEES (for staff use only) AMOUNT RCPT :# Lac*? DATE BUILDING OWNER OR AUTHORIZED AGENT DATE APPLICATION EXPIRES CITY /ZIP Issaquah, 98027 PHONE 392 -1231 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of (:ommunity De lelopro9ot prior to application submittal. Contact the Permit Coordinator at 133 - 1851 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 433 -1849. 03/30,60 COMMERCIAL — NEW COMMERCIAL BUILDINGS /ADDITIONS u Completed building permit application (one for each saucture). Ej Assessor Account Number Two sets (2) of the following C Specifications Structural calculations stamped by a Washington State license engineer Solis report stamped by a Washington State licensed engineer Topographical survey Energy calculations stamped by a Washington State licensed engineer or architect • Legal description Q Working drawings, stamped by a Washington State licensed arch Itect, which include: ; • plan s Architectural drawings. • Structural drawings • Mechanical drawings • Elevations Civil drawings Landscape plc Completed utility permit application one for entire pro Six : (8) seta;of.civil drawings NOTE:. See unity permItapplication and checklist for submittal requirements ct) lid' till d Sll s3MITTAL CHECKLIST th) 'alS/es' RACK STORAGE Completed building permit application Assessor Accornt Number • q: (2) sets of plans, which indudei. 8uflding floorplan showing Entire space wht .ractts be; •.Exit doors • Dinronskins of Tenant space floor plan s NOTE Include dimensions •of rscks;(he* and exit waye orf plan Structural cak iations stamped by a engineer (red storage S and over); RESIDENTIAL ........... NEW 1RNGLf fAiAILY: OWE WNGS/AD Completed building permit applicati (one' for e structure): • Legal description ❑ Assessor Account Number:: • we sets (2) o f working drawii �Site Foundation plan door plan • Roof plan Building eievattons (ail; views Building cross- section Structural : framing plan • WashIngtont Energy; Code:da Completed utility pttrmit application Six <(6) sets.of site piens showing utilities NOTE Balloting s W plan and linty site plan may bit .combineci See unity permit application and checklist for apecNl• submittal lequiremente • • pograpIr cal an sods informatkrn: may be requkod d uniqu sloe: t didons C OMMERCIAL : IMPROVEMENTS. . Com building perm application (one for each structure or - nant) Assessor Account Number C Two.(2) sets of construction plans, which. include. Slte: plan ; r Location of tenant space Existing and proposed parking • Overall building plan • Tenant location' Use of adjacent (common wall}: tenant Overall dimensions'of building;or square footage Floor plan of proposed tenant space anent space`plan with use of_ each room label Exit doors, egress patterns New walls,; existing wall; and walls to be :demo Construction details • Cross sections showing wall construction and method o attachment for ftoot:and : ceiling.. Structural calcutations stamped by a Washington State,iicens engineer may be required if structural work is to be done (2 sets NOTE If any utility work Is to be done, submit separate utility permit ''application and plans REROOF > . • C Completed building permit application (one for •each structure) C Assessor Account •Number r— Narrative describing existin roof, matarial being removed, an d . being installed NOTE A cerdlication.letter Is required pnor; final In and ... AN TENNNSATEU.ITE.. DI811 > . E completedf building parn.it application • one for. each structu matanat being , removed, an Assessor. Account : Nu i Two: (2) •sets of plans, which include . RESIDENTIAL REMODELS:. • Completed building permit application C Assessor Account Number •Two (2) sets :of working drawings which inclu • Site plan :;+.'Foundation plan Flrorp!4n ::• Roof plan • Bti.iilding elevations (all;views • Building cross#A • Structural framing p NOTE: If.a ny.titilityWaik la be dare provide utility permit applicati and plans must b submitted REROOFS C Completed fuildng permit application` (one for each structure Assessor A ccou nt N umber; : Narrative describing i:existing mat being installed NOTE A certlflcatlon lanai is required prior. ;o / I nal In spection and sign; Oft of.. the.permlf :' PROJECT: &II • f 41 PERMIT NO. Q SITE ADDRESS: • cn $ El U■.) 3 DATE CALLED: TYPE OF INSPECTION lit noL a.m. DATE WANTED: l4 ( q ) • . SPECIAL INSTRUCTIONS: REQUESTER: , • • PHONE NO.: . Q 1�51 INSPECTION RESULTS/COMMENTS: . .• 7d -a).. ' lc_ 11 ' 1 1 - ■rniumminINIIIIIIMMIIII■ INSPECTOR: DATE: 4 CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431-3670 INSPECTIOCNI RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 "X" REQUIRED INSPECTIONS PHONE AP DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 X 2 Foundation & Tie Downs 431 -3670 Ni-A 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 7 Framing 431 -3670 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 10 Wall Board Fastening 431 -3670 11 12 13 x 14 FIRE FINAL insp: 575 -4407 hi l- .4e4.0 X 15 PLANNING FINAL 431 -3670 Ai t R h 16 PUBLIC WORKS FINAL 431 -3670 x 17 BUILDING FINAL 431 -3670 (INSPECTOI? COMMENT SECTION ON REVERSE) CUILUIIVIa YCFfMI INSPECTION RECORD CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 (Post with Building Permit In conspicuous place) BUILDING (s) r �3 PERMIT NO. , DATE ISSUED: PROJECT: Boeing 1i7 -383 CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE INSPECTION PROCEDURES AND REQUIREMENTS 1 -1)- J@- All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping Is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be Installed to keep attic ventilation points dear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) -- King County Health Department -- 296 -4732 Electrical — Washington. State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. O9114 CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUti 14' /LA. WASHINGTON 98188 Plan Check #90 -070: Boeing #7 -383 9800 E Marginal Wy S PHONE p (206) 433 18011 THE FOLLOWING COMMENTS APPLY TO AND BECOME AR _ OF THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER (oSQ- _ . 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (277- 7272). 3. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 4. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 5. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 6. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 7. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 8. Validity-of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority-or violate or cancel the provisions of this code shall be valid. 9. Approval of the installation of this structure is subject to Tukwila Administrative Policy Procedure (see attached copy). Gary l.. Vnt/haen, Jlavur REQUIRED INSPECTIONS cg.AN REVIEW COMMENTS PLAN CHECK # qQ -Q70 PROJEC`f lei t NCG( t'.1 - 7.'- 3E �`/ No changes will be made to the plane unless approved by th (,;2 Tukwila Building Division. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). ti.) All structural concrete to be special Inspected (Sec. 306, UBC). 0 . Ali structural welding to be done by W.A.B.O. certified weldor and special inspected (Sec. 306, UBC). 0 All high-strength bolting to be special inspected (See. 308, UBC). Re 18. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (277. 7272). All mechanical work shall be under separate permit through the City of Tukwila. All permits, Inspection records, and approved plane shall bo posted at the job site prior to the start of any construction. When special inspection is required either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the Inspection agencies prior to the first building Inspection, Copies of all special inspection reports shall bo submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being Inspected. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced II over eight (8) feet In length. Readily accessible access to roof mounted equipment la required. Engineeroed trues drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear Identification showing the fire performance rating thereof. Subgrade preparation Including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given In the soils report prior to final inspection (see attached procedure). A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). Ail construction to be done In conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department Inspection should be made by calling King County Health Department, 2964787, at least three working days prior to desire inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by that agency on the job site. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall boar identification showing the fire performance rating thereof. Such Identification shall be Issued by an approved agency having a service for Inspection at the factory. 0 Notify the City of Tukwila Building Division prior to placing any concrete. This procedure Is in addition to any requirements for special Inspection. 0 Ali spray applied fireproofing as required by U.B.C. Standard No. 43-8, shall be special Inspected. All wood to remain In placed concrete shall be treated wood. 0 All structural masonry shall be special inspected per U.B.C. Section 308 (a) 7. Validity of Permit. The Issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. A{'ROOAL OF - like t NSTAL .taTtON 5TRt7G'riO Re. 1`a 'SIll3JEGT '(a '7ut< Wlt.A. AOMtNteaTRA Ft,Gt 9 rCE E t C' . 11TACI Q 1DLIccA) 1 Footings 2 Foundation 4 rie -touo. 3 Slab /Slab Insulation 4 Shear Well Nailing 5 Roof Sheathing Nailing 6 Masonry Chimney 7 Framing 8 Insulation 9 Suspended Ceiling 10 Wall Board Fastening 11 12 13 14 FIRE FINAL 15 PLANNING FINAL 16 PUBLIC WORKS FINAL 17 BUILDING FINAL REQUIRED INSPECTIONS cg.AN REVIEW COMMENTS PLAN CHECK # qQ -Q70 PROJEC`f lei t NCG( t'.1 - 7.'- 3E �`/ No changes will be made to the plane unless approved by th (,;2 Tukwila Building Division. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). ti.) All structural concrete to be special Inspected (Sec. 306, UBC). 0 . Ali structural welding to be done by W.A.B.O. certified weldor and special inspected (Sec. 306, UBC). 0 All high-strength bolting to be special inspected (See. 308, UBC). Re 18. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (277. 7272). All mechanical work shall be under separate permit through the City of Tukwila. All permits, Inspection records, and approved plane shall bo posted at the job site prior to the start of any construction. When special inspection is required either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the Inspection agencies prior to the first building Inspection, Copies of all special inspection reports shall bo submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being Inspected. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced II over eight (8) feet In length. Readily accessible access to roof mounted equipment la required. Engineeroed trues drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear Identification showing the fire performance rating thereof. Subgrade preparation Including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given In the soils report prior to final inspection (see attached procedure). A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). Ail construction to be done In conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department Inspection should be made by calling King County Health Department, 2964787, at least three working days prior to desire inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by that agency on the job site. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall boar identification showing the fire performance rating thereof. Such Identification shall be Issued by an approved agency having a service for Inspection at the factory. 0 Notify the City of Tukwila Building Division prior to placing any concrete. This procedure Is in addition to any requirements for special Inspection. 0 Ali spray applied fireproofing as required by U.B.C. Standard No. 43-8, shall be special Inspected. All wood to remain In placed concrete shall be treated wood. 0 All structural masonry shall be special inspected per U.B.C. Section 308 (a) 7. Validity of Permit. The Issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. A{'ROOAL OF - like t NSTAL .taTtON 5TRt7G'riO Re. 1`a 'SIll3JEGT '(a '7ut< Wlt.A. AOMtNteaTRA Ft,Gt 9 rCE E t C' . 11TACI Q 1DLIccA) SUBJECT: Temporary Portable Offices. PURPOSE: STATEMENT OF POLICY: ADMINISTRATIVE POLICY PROCEDURE To outline the procedure and requirements for permitting portable offices on a temporary basis. There is hereby established an Administrative Policy for the administrative review of and final action on temporary portable office structures under the authority of the Zoning Code. The review and decision procedures are as follows: 1. Temporary portable single story office structures that meet the State factory inspection requirements are logical and reasonable appurtenances customarily accessory to permitted uses in the M -1, M -2L and M -2 zones. Review of proposed temporary portable office structures shall be through the normal building permit process. The standard of review and conditions to be imposed on these permits shall be: A. Eighteen months after approval of the permit the structures shall be completely removed from the property, B. Uniform Building Code requirements shall be met, C. Adequate parking, vehicular access and safety separation for fire protection /prevention between the structures shall be demonstrated, and D. To the maximum extent feasible the structures shall not be visible from public streets. 2. Construction offices (job shacks) for contractors constructing permanent buildings shall be permitted for the duration of construction in all zones. This shall include residences for commercial construction security personnel, but not the owner of the property. 3. Temporary single story offices shall be permitted during remodeling of office spaces in office, commercial and industrial zones for the period of the remodeling, but not to exceed 6 months. Page 2 4. Governmental and public educational institution temporary offices or classrooms shall be permitted during the period of remodeling or construction of offices or classrooms in any zone where the use is allowed, unless authorized for longer period by the Planning Commission. Review of applications for these temporary offices or classrooms shall be through the normal building permit process and shall maximize parking and vehicular circulation. EFFECTIVE: Immediately 'K o APPROVAL:.✓ DATE: .213 - ?Y CRY OF TUKWMLA Department of Community Development - Building Division Phone: (206) 431 -3670 ADDRESS: CI C O � Mq.eb I ta. W/ DATE: �? Gi TYPE OF CONSTRUCTION LOCATION ON PROPERTY BUILDING HEIGHT /# OF STORIES FLOOR AREA OCCUPANT LOAD 16t1 , 7-351 EXITING REQUIREMENTS DETAILED REQUIREMENTS OCCUPANCY TYPE OF CONSTRUCTION ..4 PART V, CHAPTER 23, U.B.C. NOTES PREPARED BY: 60 5$ 2 4,3 385 MeDivte &. M1N. cage exit ✓o. K W.S.E.C. L 4r J�orts ®tcnQw CHAPTER 51.10, W.A.C. '�,�, (..SLSGCJ5 ?QOO t • 6300 Southcenter Boulevard — #101 Tukwila Washington 98181 OCCUPANCY GROUP _ ' )ND L ' Lr ...Sur.Istalc.Ttot4 of.tv ¶(Z. N.W.1.1t12. LS. A 686.6A c EXGe t:DN . A: 0 d] AL L► = 27 - 7 D — ONe - e:A.11.t71 5 g_LPRoDite Vole. 1 fix_ oN ALL SkAposueeG. m rsr. c . cuaD < 20 i s 140612 1 'F30GY . (iOM , Rpl,f Cc1 2-1S - ! NE 5 DATE: 2 - /3 -91 55' Fire Department Review Control Numbers 90 -068, 90 -069, 90 -070, 90 -071, 90 -072 (512) Re: The Boeing Company - 9800 East Marginal Way South, Seattle, Wa. Dear Sir: t City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 March 8, 1990 Gary L. VanDusen, Mayor The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: This review will cover all five mobil installations - Buildings #7- 381, #7- 382, #7 -383, #7 -384, #7 -385 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10 B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) (UFC 10 -1 (3 -1)) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinents, or set on shelves (NFPA 10, 1 -6.6), and shall be installed so that the top of the extinguisher is not more than 5 ft. above the floor. (NFPA 10, 1 -6.6) (UFC 10.301) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher," with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC 10.301) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) There shall be no enclosed usable space under City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Page number 2 Gary L. VanDusen, Mayor stairways in an exit enclosure, nor shall the open space under such stairways be used for any purpose. (UFC 12.106(c)) Exit signs shall be installed at required exit doorways and where otherwise necessary to clearly indicate the direction of egress. Signs shall be of a contrasting color with the surrounding area and shall have letters not less than six inches high with a minimum letter width of 3/4 ". (UBC 3314) (UFC 12.108) 3. A fire alarm system is required to be installed and functionally tested. (UFC 10.301) Local UL Central Station supervision is required. (City Ordinance #1327) 4. All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NEC 70) (UFC 85.101) All electrical wiring is to be inspected by the State Electrical Inspector, Washington State Department of Labor & Industries. (NEC 70) 5. In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. Numbers shall contrast with their background. (UFC 10.208) 4- Dear Mr. Griffin: EVERDREEN MOBILE COMPANY CUSTOM DESIGNED AND MANUFACTURED MOBILE STRUCTURES February 22, 1990 Mr. Duane Griffin, Building Official City of Tukwila Department of Community Development - Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 Subject: Permit Application /The Boeing Company Five Single -Wide Trailers As requested following our meeting yesterday afternoon, here is a breakdown by trailer of the onsite costs associated with the installation of the five buildings that are set up on Boeing property at 9800 East Marginal Way South. 1. Boeing Building 7 -381 (Serial No. 1189 -123), 14' x 52' Modular Structure: Deliver to Site $ 175.00 Block /Level /Set 330.00 Skirting, Plywood Backed 320.00 Tiedowns 270.00 Decks /Ramps (Pro Rated) 2,023.00 Total Onsite Costs, This Unit... $3,118.00 2. Boeing Building 7 -382 (Serial Number 1189 -124), 14' x 52' Modular Structure: Deliver to Site $ 175.00 Block /Level /Set 330.00 Skirting, Plywood Backed 320.00 Tiedowns 270.00 Decks /Ramps (Pro Rated) 2,023.00 Total Onsite Costs, This Unit... $3,118.00 22433 6.2, 56th • P.O. SOX 1043 • ISSAOUAFI, WA 86027 206 3s2 -1231 FAX 206 392 -2617 RC_CI:IV',: D CITY OF TUKWILA FEB 231990 PERMIT CENTER GLW:ch Mr. Gr ff n c ontinued February 22, 1990 Page -2- 3. Boeing Building 7 -383 (Serial Number 1189 -122), 12' x 42' Office Trailer: Deliver to Site $ 140.00 Block /Level /Set 125.00 Skirting, Plywood Backed 486.00 Tiedowns 270.00 Decks /Ramps (Pro Rated) 2,023.00 Total Onsite Costs, This Unit... $3,044.00 4. Boeing Building 7 -384 (Serial Number 1189 -121), 12' x 42' Office Trailer: Deliver to Site $ 140.00 Block /Level /Set 125.00 Skirting, Plywood Backed 486.00 Tiedowns 270.00 Decks /Ramps (Pro Rated) 2,023.00 Total Onsite Costs, This Unit $3,044.00 5. Boeing Building 7 -385 (Serial Number 1089 -104), 14' x 24' Self - Contained Restroom Trailer: Deliver to Site $ 70.00 Block /Level /Set 240.00 Skirting, Plywood Backed 342.00 Tiedowns 180.00 Decks /Ramps (Pro- Rated) 2,023.00 Total Onsite Costs, This Unit... $2,855.00 TOTAL COSTS, THIS PROJECT: $15,179.00 Hopefully this information will be adequate to complete the application process to your satisfaction. GT'WL. Wilson Special Projects :•••••' • . Puget Sound-Developmental Center 7,8 E. Marotriat Way $., S*10011, WA 0810S N . •7 442tt.-14.. • • i • y m.,..,..,0•••••■••••••••••••••••t• • • 1 ., '71 - • •!., , • , - 4, s. 4 mono u • :tinii.6.4-ros, * • . Vr.io • 0 KEIASTOP •Is.• • . \130E: ••• • ••• IttAPORaZ • • ;: • ' \\•;,k.... -‘, \ • i i ,.„ A • trove , , ..; 4 satesswase•evis l'‘ %,•••-•-.-- ' 'CP" N-IPOCR TAU= &Eta i •. N: ••■ •` mottoes ." - \ • • titP5ECESYCI AFEAS ' . ''•.1 • ' amowspeweico L.. • PESMICTIEZ PAYINAR1 I &ENT* StYS MOP • •••=:•:"N ..... ....... • • A •. ••-•'••. ... . •. . • . • 43 • .01 1m • _n, 1 EArt NA.9b2N.M. WAS/ =POOP.= PAPIg • • • . ' • .411 Mit/ •• SEATTLE-T4C0h1P, AP.PORT • ft 44. .Y • t-t ,...i..„........,siominkow 7 .. i:.-Z ".. . • ,,. . - i' •■•• • - 't '' • C , 1'..: .-. i ' ‘ 0 .!. 10 ?Aci#V ' • -., - 3 • • , .a.r+ ,..•_, , . V it t,,, .. ...t•ItItte2k.._ , '.....%:... . •: t .rie4• ACTPANY j„.........".;cr:•i••‘`'".ii.;• • : ;.: • '--. • • -- \ ' s ,.. 7440 -. .. . .1..oraili.i.; , "•• c • t j • • • N. • it7 FROM '- '1/4, • . %. • • $ • ••••‘;,.., •*•••' • • • s, „.•• •• .•5` • • FROM KENT:',%t. kkt.So'itt.ASIJRN ‘• • ' 5 iA0BURN . mota .1' • , FREEWAY • Th.c ". CD., a- ,...in.iAtl,,,°•, nd in consider:A.:too tit '1 • t?oirseyn and iissit claim to IX/E111G:11111 COI:INY, a Delaware :en:A • the clrc ouribed reisl Darnel 1: •L „portion Alm •riy4otlyv Crow ' • • ;44 loccoted.1 it noutioo A:4 tOt?.1Ji • 2. north, • oust, •V. 4 Lint.; County, Jusyliiti ..eczci•lbsod • us. tondos:: t ;Joint .. 01! Ltd: costt. lino of cia It/ o;volion • , • • A.:, ddosito Is; iotei•oa.octon by iiuj whien is; .." bar ic.12 of out: 1.41r1,110.1 to tliu t.ouLt Lnu oi' • • Tiisottly Oroa Donation Lund Claits; thonoo nortto • mot iTarallol to :zooid Noutti .tt.10 :cot to point on tho noottowoniurly lino or ,:t1dit1on to t.ocint; Lc1d Couilty AirpOrt au ftist and Josicribod in Iiinz; , County Sup-orior *out Cnuno ;to. :-.:28201; th:inesc: ilortn ,, .11°20 ;lost along; Auld nouthuout(rI) lino 5:17.30 feat .to the 1.riso point oryt Cosiat:o noy•Lto •'',Ii1/984. parallel iti the Lint! I 'I 11..1 DonatIonClaiut..71i0.26 rout to trio northi:onlarry •• ; of Primary atoto 1ikwaiy$o. 1. (alsio !amen as' 24.1::ot , • . Margien1 .W1k);, north --33°•22 hoot plot.- nia LI • ' 4ortlyeatathrly lino d1 t(. fact; thuticu coloth UCti;.•:t ...• - osin,t parallel to Lllo .nouth J. non:Ai-on' Clclioy 709.44 root-J..4a the :notethayoutorly Iino of y..1.11 Lion - to toonfig; Coulity.iir,sert; thaloce bOtittl 44 10 T.:61.31.., 1401411 ayou'i4 nswitin4ibLerly•-3.1no Jj sotothwentOrly, 11;x: • Bpi:C*1'41° 2LIt10 nue t .110 .roty to the Algol - 11.0!4t or • .". • • • 7 • - r „, --A • • • 44, ;1.ocated.:istlidaCt1ost nOrth,, lid V.ittg.Causriy;'...bifithliSgton, doe'Crilictl an •' • • • •. -130gini1in4!01; 4 int 'this; cif bola toitsttloil 4, -411st3 • it . intorno° Lod Py t lista viol:lets fect neortti cif and parallal to tho uouth. lltic of TiRiothy Crow DO/station Lund Claim; theiu ec. north it9u84 boot in:rolls:1 to twist %outli Lino Io10,00 icc:t wore or lens.: to a point %Nilo.% io OlI foot- oas.Lc•3y, mousuroki 41(1111: s id - 1 , 11'0141 tlitt 110r 1.3.t0.1. 1.y 1 I Is II(' or Triralary totto to •Dighway. 1:1•:;:-.• (alt.° ts.licor.,,, Marginal flay) alio tM3 .truoN,:otilt. or 1...,:oloosio;;,; ch.:owe or •13°42 A 4:1" iron t par a 1 lol to Liu 1,1 nor Liroaa Lori y I ino 4U &d hic1Jw2y :Coot; theono north Cb":.11'..:0" T/Gkrt DICTI1,1 2-1310 pya•zi 1101 • LM flow • Donation. Litant Claim itO„I.:4) roe t; 1.11c Hoe nor Lie ;;.1* ,"' west, Oaralloi to uaid uortIonastarly line or bald - highway 1 11.04: foot; tboycno C7 wsosii 21;11,..ta . -feet to the. swirLhouNLorly :gad Il.b%.LI ; t Nu Nylej :ota olti OUS1 Ult.till; nu id 110r i,t1 LC - 1.11114 - r 247 •'; Ot.;' foyyt yolor( or luny, to lo'voilit lit voy•allei witt: oho eouth Ukh. of sitild'Donation Claim allic12..daisi ' parallel lino iItO'c:tl LI trot; in).iast ot Ing.,iyinito,,;; theUouth 89 tuawi.i.aral /el th &.0 Us •• .11:10 or :staid Lostation Claim 30€ Tort to Liao triie point Pr --; ..."" 'O i. ' '• • -2/i'v c , 7;51 • • AST 11.01111... Tr -•'•- - • • _ • • .1 • • • • At'S1 _ 11 ARcit.NA.L., - I 1.• WAy I. 4' BLO _ aLto 44- 11 44.1 VW. t1e)c -124 42" , fl 1 t 1-3 eL0 a:V.4'118%42z Iv- Nas•* FL I I - •=ic X- -•-•i ••••• •■•■■• •••.'••••...•••••••••••••••••■••• DESCRIPTION ; DATE - FILE COPY I understand that the Plan Check approvals are ..Jbject to error and omissions and ;approval of plans does not authorize the violation of any adopted code or ordinance. Receip of contradoes copy of approved plans ac Weed By/Ma Date Permit NoLD..5 , 1 EVERGREEN MOBILE 4 COMPANY JOB NO. 2 ED52 DRAWN BY p CHECKED BY CITY OF TUI(WiLA A P P R E D FEB 9 .0 1 7 :14&.1001, BUIL )!NG DIVISION AWING IS:1z SALES: 22433 S.E. 56th ISSAOUAH. WA 98027 P.O. BOX 1043 (:3) 392-1231 PRODUCTION: 14219 - 35th AVE. N.E. MARYSVILLE. WA 98270 (206) 553-7577 S/N APPROVAL DATE 1/3/90 JOB NAME 60E:ANC:i FL isr..)i--17 L LT THIS DRAWING CANNOT BE REPRODUCED WITHOUT WRITTEN CONSENT Of EVERGREEN MOBILE COMPANY H 4 KESTREL BLUEPRINT INC./ , 130772 111 1 1 1 1 1 1 111 1 1 11 1 1 11 1 111 1 1 k 1 1.1 III 11 . - 7 • • • yi ••1 1 ••• I'''1 1. "1'1"111 . 1 . '1 1 ''' 0 THS INCH 2 3 111 111 111 4 111 III ! ij 11111111111111111 11111111111111;1111111111 t 7 szz 111111111 • 1 11 1111111111111111111111111111ii111 ym • t;.. -.�; .: -£..4 EVERGREEN MOBILE .. COMPANY JOB NO. ... S/N DRAWN BY frlt,,, APPROVAL CHECKED BY DATE (/;i, JOB NAME v ,p_061I DRAWING 6 i - ffr THIS OPAWMIv CANNOT SE REPRODUCED WITHOUT WRITTEN CONSENT OF EVERGREEN MOBILE COMPANY SALES: 22433 S.E. 56th ISSAQUAH, WA 98027 P.O. BOX 1043 (206) 392 -1231 PRODUCTION: 14219 - 35th AVE. N.E MARYSVILLE, WA 96270 (206) 653.7577 • . KESTREL BLUEPRINT INC./ .130772 r G i.-r) -7- : r :, U i Lf7! f- -i1 t � • \ . 3 2 J -02 is D 4_,t_. F (' f'x� ( ►'!... 6r �I�i 5rr- � _ .._ 7 LULt7iH61 1-1 p. `Ja 1 7 f, B -123. =4*-1 1 =4 _I ___..........,.....____ _ E DESCRIPTION I' IIJIJIII IIIIIIJIIII IIIIIIIIIIIIIIIII . LII�IIiII I IIIIJIIIIIIIJIIIIIIIIIIIIIIIf IIIIIII IIIIIIIIIIIIIIIIIIIIIf I�III�III�IIII IIIIIIIIIIIIIIIIIIII'ilI IIIIIIIj IfI III'II II tII I 0 16THSINCH 1 2 3 4 5 6 7 £3 9 . 10 11 MAXEINGERMANT 12 9 n fan A- 108g -104 CITY OF TUKWILA APPROVED - FEB 2O'9.:: AS NOTED BUILDING DIVISION P T t t_ 1.7 -- DtzTA L. r0 PL. AKI V . iEVE1a)(42._ IsLa-i .tr.7• 1 ivi kt's.), kk t,,,...,T t-i 3 (OR Va ) . :Zt_./...k.... 1" . :,.0 t■4 C. 1 .,,,' 3 t S e:t--. ..1;lei' :- t=; a:- It 611.1.3 - L en A' ; . . Lt...e 1. --!.41.1 .•..T.Z. . .:4..;.. Kt dx I r---i - A. - 7r I - .9 -- ,71 : ::::::: r'........ ''....' _ . : - i '& o 1 1 : 1.- - tc:Ilact;.4.E..7".E.7_,.. ZL A a ," 0 . cn.-Q ci. .-. -. - a.: ea : 1 ..... tad Len . . _. - ( ax 1 ,-......r L LJ.--;, tr-- I C3 V-.-4 li.L.:( i. . : ' cc:5 V.--.1 _ . I-1 E. DOW t‘iAl p ;et:5 •-- - T - FE.'F' / P s Na (7,7 j i57. - Ls 15 EAF-C O - 1 1.,s7R 1 • -**;› :•:- • wIp " fOlzSt Teon.4 /5 .: _ _ .3:‘ .7.7 II ..-. - - a. an 41r_ s REV. NO. Spliie Device Cat. No. SO Required for the tensioning of frame and or - roof ties with all tension •head anchors. 16-0030 • BISB aflg BCL.T & . ' tree Root Codified 0:1 \44 ** -111.1111P-2-1 vavired Stracciad cookouts tv ANSI 4119.1 • - and HIM scecifteetion tor mobile home Os - - devficetioo and tios e !vivito= Wil e *length 014150 16-0070 S42 42° 6111.1. STRAPPING 16-0071 SSO 60/ ROLL - SMUT IN 164072 s 670 670 HtiLI - 'STRIPPING COMM GAMIN= SIMPPRiG DESCRIPTION ) installs easily into existing concrete slabs or footings with only a 5/8" drilled bole for expeosion anchor bolt. 24 percortion @ 30 lbs. • NUT h BOLT NOT INCLUDED PLEASE ORDER SEPARATELY SOLD PER EACH 16-0040 - ICS-2 CONCRETE SLAB AcJfl EVERGREEN MOBILE OMPANY S/N •1 — 1 ra2.- APPROVAL DATE Nv.. ct JOB NAME tsc,:v FLA H - s SHT. oFr ; a.. INN BY CKED BY THIS DRAWING CANNOT BE REPRODUCED wirmoin WHITTEN CONSEN1 OF EVERGREEN MOBILE COMPANY CITY OF TUKWILA APPROVED FEB !A AS NOTED BUILDING DIVISION! SALES: 22433 S E 56th ISSAQUAH, WA 98027 P.O. BOX 1043 (206) 392-1231 PRODUCTION: 14219 - 35th AVE. N.E. MARYSVILLE, WA 98270 (206) 653-7577 KESTREL BLUEPRINT INC.! 130772 • I. r ^ - • • 0 16 THS INCH 2 3 Li. F S 7 P 0 rl 11 S.M Ita neen■wsiv ‘iBLOC1 LI KV a r'xF-s 1 ' , c DE TA\ t L. = "ce> C, 3/ c:," ft, -.S. TM EL. 1`11-7, TZ) / . TAP F 1 0 , - * r " . " ; - crai tN,,T e..r5 . . I IZOWhL .14:1 .5 a, z 11 \*L (c.„-E-, E.Gaft• L , Arz.H .C )-6 - le5L":114 . 1 t 1 '4 G/ t- - 1774E Dovit - - • - - . LAE! : = 7i Z:5 ci.V-;7 vc-i •:5' F.r. it:741;a' .s " - t I; YYN . .tZ - 4. z k :12YOWU CAL.C._5 LJ ESC . JOT f FPI r 45TER t8( DL'.'R GE PA Pscir- Cif!>.31'rtap Iron Rent estlifled Cst- vanited Stiepping etetforrns to ANSI A/19.1 anti HUD rgeettketion kr mobile how tie dorm toprcaticit awl has a minimal tee strength at 4750 Its 16•0070 $42 421 STRAPPING PO 60' RIXL STRA.PPIN 16-0072 S 670 670' RdU. - STRAPP1 Installs easily Into existing concrete siabs or footings with only a 54" drilled hole for expansion anchor bolt. • 24 per carton os ibs. • . & BOLT /far INCLUDED PLEASE ORDEtt SEPARATELY Soto PR EACH 1CS-2 CONCRETE .SLAS MOOR REV. NO. STRA.P RUT- . • Required for the tensioning of frame and or • wines with all tension head anchors. 16-0030 BIM STRAP SOLT & NUT DESCPVTION EVERGREEN MOBILE 4 COMPANY JOB Nt3._ ze:) a DRAWN 1 - APPROVAL CITY OF TUKWILA APPROVED - FEB 20 AS NOTED BUILDING DIVISION SALES: 22433 S.E. 56th ISSAQUAH, WA 98027 P.O. BOX 1043 (206) 392-1231 PRODUCTION: 14219 - 35th AVE. N.E. MARVSVILLE, WA 98270 (206) 653-7577 Piq 1189 12.3A 124;7 JOB NA ME Is:1Z ILK FAA ad CHECKED BY DATE--11-40 L4E OFF "el - SLIT. THIS DRAWING CANNOT SE REPRODUCED WITHOUT WRITTEN CONSENT OF EVERGREEN RAOSILE COMPANY KESTREL BLUEPRINT INC.! .130772 ^ • ";, , , , ,j■ 1 .■■•■•••••••• 1r O. I IIIII t g L , 11111111111111111 I 1111 1 6 16 THS INCH 2 3 4 D 6 7 8 9 , 10 11 P '" E IN GERMANY 12 :173, 41. rt REV. NO. JOB NO./20 DRAWN BY CHECKED BY EVERGREEN MOBILE COMPANY -2.051 - 2052- DRAWING 1-b,g / y S/N APPROVAL DATE IS NAME !NVv 'FLI -tT L1 THIS DRAWING CANNOT BE REPRODUCED WITHOUT WRITTEN CONSENT OF EVERGREEN MOBILE COMPANY SALES: 22433 S.E. 66th ISSAQUAH. WA 98027 P.O. BOX 1043 (206) 392-1231 PRODUCTION: 142:9 - 35th AVE. N.E. MARYSVILLE, WA 98270 (206) 653-7577 SHT. I -- - -- -- 1' T • KEETRaL VLUEPRINT INC./ .130772 C 1 �� -- 4x.4 pas T5 G -(50 "at C., ATh "`M►4 r -) L_ { 4I (I Nr-P - L. ( P ,P -Jr ' r T ^ _ y I , ' va f } - . 1.1- }g4 '� -� --_ I J i "RAW: • '0 74Nt4. , :Ai }sir OPt • i _. I� {� - - 't' i I III I I1h I h1I I I1I I I1I I I1I I I1I I hII I I I I I I I I I I #' IL # I � I I I + I i I I I � Ii l i # I I I l l 0 16 THC INCH 1 2 3 4 4' f 3 -21s $ 7 . 14A Kurt Or- • -•ML-1 4: r—•- I { �,,:,�- „.,, -.•r ,..�.r�- •�'+�- -_ —•'v -ter. .- �- .. .r..- ^= T'.'_ "°'-"" �- w..a >. .. - •Y ~Y-- .....r._....� -n .... -.._ Apt io . e. w. i.a,,,.--.-.»... M w.... .............,..- M.w..r..e..n ... �-- t..1 4E eor4 C. O r e - t I --4 $ Ida �2 L pert..t.w. f 1.4rt 'e r=' 1441, 1111111111111111111111111111I1 11111111111 111111i11111111 I11111'1 Till � ll .. IL I_ LIL I i . la l . l . 1 , ll . �.1 1 l 1 �I�I I �` ill � l � l � ll 5 6 7 8 9 1 O 1 1 MADE IN GERMANY 1 2:474 CITY OF TUKWILA APPR0\1ED FEB 20 '. AS NOTED BUILDING DIVISION! I : ALLAN C I • 4 11 S. f Of • o - 1, 1 E r Nr k Iili' t :1i» II 1 1 T MB $ DOMING CANNOT BE REPRODUCED WtT$OUT WRITTEN CONSENT OF EVERGREEN 61098E COMPANY ELECTRICAL SCHEDULE SYM. I QTY. 2'X 4'TROFFERS LITHOtIIA 02SPG- 240-Al2- ES- 120-PV PARCH LIGHT PROGRESS 1P -5511 ONE VAT SVI?CH 2 LEVI 101451 -I 10 DUPLEX OUTLET, NEMA 5-15R, WWII *5262 RAE( IRITLET, NBA 5.208, ISOLATED GR["a1ND, HUBBELL 111G-5362 DIRECT CONNECT 1 FRAME FOR FUTURE = 3' -0 °X 6' -8' ACTIVE DESCRIPTION W/ 5'W X 20'H VISION WINDOW, WOOD JAMB & BRICKMOULD 4 FRAME FOR FUTURE 46'X 39' INSULATED IND. SLIDER _ -. ',FLOOR 3.CEILING /ROOF S.PLUMBING :ELECTRICAL A. UNDERCLOSURE' 7/16' PEL.BD. A. 2'X 4' SUSPD ACST CMG . . A . PLUMBING: NONE A. PANEL' UD 12L 100 D/S 100A 2(96V. B. FLOOR JOIST' 2X8 TRANSVERSE V/ REGENCY TILE DONN 'DX' GRID B. PANEL COVER' QOC 2OU 100 F/S C. RIM JOIST' 2X8 DOUBLE B..F D. F.S. - 25 C. SERVICE WIRE1 GI RN 'INSULATION+ R -1i C. FRAMING' 2'X Ms. 6.HEATING (3) #2 BLK, #6 WHT, #8 GRN E. SUB - FLOOR' 3/4' T &G PLYYD D. INSULATION' R -30 FF 5 A. INTERTHERM #AWY- 024 -B10 D. SWITCHES! (2)1 -WAY F. VINYL FLOOR' E. 1X4 LUNGITUD. VENT STRIPS f3 • 24,000 BTU AIR E. RECEPTACLES' (11) LASALLE DEITCH- DIAMOND4#9002 F. ROOF SHEATHING' 7/16 PEL. BD 35,000 Bl'U HEAT F. LIGHTS' (10) 2'X 4' TROFFER' I G. ROOFING' DUROLAST 230/I1OV- 141 -6OCY. 43.3 AMPS LITH IA #2SPG 240- Al2- ES--120-PV 2.WALLS ice's pig r.1%. cv A L?F1 (U PORCH LITE' PROGRESS &P-511. A. INTERIOR' 1/4' CIt AMOK BIRCH 4.MISCELLANEOUS ALL CREAM DUCTING .G b � G. TELEPHONE OUTLETS' (7) B STUDSi 2X4 X SD Y'�TUD 16 A. INTERIOR TRIM' t'' REFINISHED - 'X 20 10' ! H. HVAC " DISCONNECT' 60A. FUSE C. TOP - PLATE' DOUBLE 2X4 COLONY OAK TRANSITION - 8'X 16' TO 8`X 16' . D, BOTTOM PLATE' SINGLE 2X4 DUCTING - 8'X 16`)( 30' • • ` E, INSULATION' R -11 END CAF' 8'X 16' --i F. EXTERIOR' 1 X 4 BELT RAILS WHITE ROGER 1F90 -1 THERMOSTAT G. BLOUSING' 16'TOP/ . 12' BOTTOM f . $' t `= Fig -. ' ' H. SKIN ,019 ALUM. WINDOW . AND DOOR SCHEDULE 1 RHR • 4 1/2' 36 1/2'X 80 1/4' --- 4 1 /E' 46 5/8' X I 39 5/8' DESCRIPTION 000R FINISH' WAL R.O. SWING SILL HARDWARE' 1REMARKS THICK' THICK' HEIGHT' 3' -0'X 6' -8' MTL. INSUL. DOOR 1 3/4' PAINT 4 1/2' 38`X 82' 1 LHR -"`- >1AIIYA.E 5407-07 EVER) STD. HMIES & CLOSER YALE LIX:KSET OMB) PANEL 1A 100 AMP CONN LOAD 13.0 _kVA 36 ASPS @ 208Y/120 V, 3 PH OT TO SCALE SCALE' 1/4' = 1' -0' exga JUNCTION BOX TO SERVICE POINT FLOOR PLAN / BLDG, #1 REV. NO. DESSAIPTION M 7 MIME CABINE1 NEM --- - 100 AMP.2Y /i9 v, 30 POWER PANEL W /2' NIPPLE 1,S.R8 X4' J-BOX - /-- 60 AMP DISCONNECT SWITCH r - INTERTHERM ?#AWY- 024E -10 24,000 BTU "AIR 35,000 BTU HEAT 230/11OV- 10 -60CY, 43.3 AMPS RETURN AIR OPNG, 20'V X 12'H JOB NO. DRAWN BY . CHECKED BY JOB NAME . i EVERGREEN MOBILE COMPANY DRAWING °' - p i1/4 SIN f tad ,: };. }. SALES: 22433 S.E.--561h ISSAQUAH, WA 98027 PQ. BOX 1043 (206) 392 -1231 PHO UCTIUi3: 14219 - 35th AVE. M.E. MARYSVILLE, WA 98270 (2O6)653'7577 APPROVAL eLo_ �•- �`�3 DATE I SHT KESTREL BLUEPRINT INC./ .130772 P 0 16 THY INCH 1 2 3 111111111'11111'111111j 1 1 1 1 1 1 1 111111111111Ij . 1.11 . 111111111111I1111'J 1 11 IIIII '1111111111I111I�I1� 7 8 9 10 NOTE: If the microfilmed document is less clear tan this _. -..:Y • 11 MADE IN GERMANY 2 PANEL SCHEDULE NumBER IA LOcATIoN AFL POS. 72, N.F.C. SERVING BLDG. 1 208Y/120 VOLTS 3 PHASE 4 WRE 100 AMP with MAIN BReAKER QTY LOAO DESCRIFMON TRiP AMPS 20 20 st 20 20 .--, . - - •• a II ..Th-- i g .---'-- '''' If is II 11 If TRIP AMPS 20 20 20 • 20 - - LOAD DESCRIPTION 0 1 3 5 7 9 11 23 15 LIGHTS SPARE I SPARE SPARE . SPACE WHINE SPACE t*/HDWE . SPACE W/HOME SPACE WHOWE 0.8 . - - - 0.6 0.6 0.6 0.4 10.0 (3) DUPLEX RICE T (3)' DUPLEX RECEPT. ' (3) DUPLEX RECEPT. (2) DUPLEX RECEPT. SPACE MINE • SPACE W/HOWE WC UNIT 2 a s a 10 12 14 1 REMARKS - CONNECTEDLOAD 11.0 KVA 35 AMPS DEMAND LOAD KVA AMPS MEM REv. NO. 1 JOB NO, 2 DRAWN BY • R CHECKED BY DRAWING APPROVAL &JD .-3St THIS Os CAMOT 8EFRODUCEO vinmoui. VINTTEN CONSENT Of EVERGREEN 1402111...E COMPANY S/N 1z-i AR ebno PW - 100 AMP 208VIZO V. 30 POWER PANEL W/2 NIPPLE , 6'X 6' X4' J.BOX ELEC. LIGHT PLAN / BLDG, #1 60 AMP DISCONNECT SWITCH INTERTHERM AWY-024B-10 24,000 • BTU AIR 35,000 BTU HEAT 230/110V-10-60CY. 43.3 AMPS RETURN AIR OPNG. 204 X 12'H SALES: 22433 S.E. 56Ih ISSACtUAti, WA 98027 PO. BOX 1043 (206) 3921231 PRODUCTION: 1429 - 35th AVE. 11 E. MARYSVILLE. WA 98270 1206) 653-7577 KESTREL. BLUEP11114T INC./ ,1307Y2 1 ■•• • 1 0 I6THSINCH 1 2 3 4 5 6 7 i 1-111 • 8 1111 1 I 1 1 9 11111111111 1111111111111111111111111111 10 11 mem GER.A 12 ELECTRICAL SCHEDULE SYHBOL QTY DESCRIYTION 10 2' X 4' TROFFERS LITHO'S 1123PG-240-Al2-ES-120-1 0 -0- 1 PORCH LOT PROCRESS *P-5511 $ 2 ONE VAY SWITCH LEVITIN 01451-i 10 DUPLEX OUTLET, &)A 5-15R, HUBBELL t5262 0 DUPLEX OUTLET, NEMA 5 ISOLATED GROUD, HUBBELL fIG-5362 1 7 I TELEPHONE OUTIIT 01 3 =TIM BOX L . 03 . _ _ DIRECT COMECT MEM REv. NO. 1 JOB NO, 2 DRAWN BY • R CHECKED BY DRAWING APPROVAL &JD .-3St THIS Os CAMOT 8EFRODUCEO vinmoui. VINTTEN CONSENT Of EVERGREEN 1402111...E COMPANY S/N 1z-i AR ebno PW - 100 AMP 208VIZO V. 30 POWER PANEL W/2 NIPPLE , 6'X 6' X4' J.BOX ELEC. LIGHT PLAN / BLDG, #1 60 AMP DISCONNECT SWITCH INTERTHERM AWY-024B-10 24,000 • BTU AIR 35,000 BTU HEAT 230/110V-10-60CY. 43.3 AMPS RETURN AIR OPNG. 204 X 12'H SALES: 22433 S.E. 56Ih ISSACtUAti, WA 98027 PO. BOX 1043 (206) 3921231 PRODUCTION: 1429 - 35th AVE. 11 E. MARYSVILLE. WA 98270 1206) 653-7577 KESTREL. BLUEP11114T INC./ ,1307Y2 1 ■•• • 1 0 I6THSINCH 1 2 3 4 5 6 7 i 1-111 • 8 1111 1 I 1 1 9 11111111111 1111111111111111111111111111 10 11 mem GER.A 12 FLOOR . WNO N OR SHDL Y T. DSRPIN Dii IIH AL RO WN EGT ADAE EAK HC+ TIK AE LCST (EE) (- `0) '8 I. ISL OR j 1 34 AN /' 3' 2 H RA 5 / 5W X 2' IIN WNO, I. lNE OD JM RCMUD YL ita H - PF 50-12D i SD IGS I, COE O 6 FAE FR FTR 6X 3' ISLTD ID LDR ! 4 12 6 58 9 58 6 A T ECITO --- 1 ' X 4 RFES WOI 2P-4-l-S10P OC IH 1> 4 A PEGS P51 x VY SIC EIO 15- E 6 RP 1 HBEl #22 1 UL( OTE, NH -0, IOAE RW IDL I-32 4 II ULT 0 3 ACIl BX DRC ONC SALES: 22433 S E. 56th atm erg %A BIM JUI WM ISSAQUAH, WA 98027 PO. BOX 1043 MOBILE (206) 392-1231 PRODUCTION: 14219 - 3511/ AVE. N.E. MARYSVILLE. WA 98270 (208) 653-7577 raw • i 1.FLOOR 3,CEILING/ROOF 5,PLUMBING . 7,ELECTRICAL A. UNDERCLOSURE: 7/16' PEL.BD. A. 2'X 4' SUSPD ACST CEILG . . A. PLUMBING+ NONE A. PANEL+ OD 121- 100 D/S 100A 220V. B, FLOOR JOIST+ 2X8 TRANSVERSE W/ REGENCY TILE DONN 'DX' GRID B. PANEL COVER+ QOC 20U 100 F/S C. RIM JOIST+ 2X8 DOUBLE B. FD1 F.S. - 25 C. SERVICE WIRE+ ' D. INSULATION+ R-11 C, FRAMING+. 2'X 10...... (3) #2 BLK, #6 WHT, #8 GRN SUB-FLOOR1 3/4' T&G PLYWD D. INSULATION+ R-30 FTIWZGiV,Z D, SWITCHES+ (2)1-WAY IF. VIINTY.: FLER: E. 1)(4 LONGITUE. VENT STRIPS € 12SC. - 6,HEATING E. RECEPTACLES: i - --- LASALLE DEITCH F. ROOF SHEATHING+ 7/16 PEL, BD .4. INTERTHERM #AWY-024-B10 F. LIGHTS+ (10) 2'X 4' TROFFER+ G. ROOFING: DUROLAST 24,000 BTU AIR • LITHLINIA #2SPG 2.VALLS R DRIP RAIL 35,000 BTU HEAT » PORCH UTE+ ..PRO3RESS V-5511 A. INTERIOR+ 1/4' CINNAMON BIRCH L 2 1./2'X 5'-O' GUTTER @ EXT DOORS 230/110V-10-60CY, 43.3 AMPS G. TELEPHDNE OUTLETS' (3) B. STUDS+ 2X4 It)A 7 §2 7- STUD 16 1 0.C. RETtAinairrAG H. HVAC DISCONNECT+ 60A. FUSE c. C. TOP PLATE+ DOUBLE 2X4 4.,MIKELLANUUS ALL DUCTING D. BOTTOM PLATE: SINGLE 2X4 A. INTERIOR TRIM+ PREFINISHED DUCT G - 8' an 10' E. INSULATION+ R-11 COLONY OAK TRANSITIDN - 8'X 20' ID 81 16' - 12'L F. EXTERIOR+ 1 X 4 BELT RAILS DUCTING •- 8'X 16'X 26' G. BLOUSING 16'TOP/ 12' BOTTOM END CAP - 8'X 16' H. SKIN .019 ALUM, (4) -B4 X et• DIFFUSERS WHITE wt4a. DRAWING p 001 i A. sf 4-1 v mis DflienrING CAHNOI DE StEr4lOCA;dF.0 WITHOUT 1 • 11111111111111111111111111111111111111111114iti Iv III-141 1111111111T11111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111i11111 0 16 THS INCH 1 2 3 4 5 6 7 8 9 1 i i E OERMANY 1") ' LFLOOR aCEILING/ROOF 5,PLUMBING ?ELECTRICAL A. UNDERCLOSURE: 7/16' PEL.BD. B. FLOOR JOIST' 2X8 TRANSVERSE C. RIM JOIST' 2X8 DOUBLE A. 2'X 4' SUSPD Aar CEILG k PLUMBING' NONE . A. PANED 00 12L 100 ivs 100A 220V, V/ REGENCY TILE Di Itti TX' GRID B. PANEL COVER' QOC 20U 100 F/S B. FOIL F.S. - 25 (7\ \r1; C LOSER C. SERVICE WIRE' D. D. INSULATION! R-11 C. FRAMING' 2'X 10 PAINT CREAM () #2 BLK, #6 WHT, #8 GRN D, SWITCHESI (2)1-WAY E. SUB-FLOOR' 3/4' T&G PLYWD D. INSULATION' R-30 Fila_aRGI '''S. F. VINYL FLOOR' E. 1X4 LONGITUE, VENT STRIPS 8 12'O,C. 6.HEATING E. RECEPTACLESt (10) LASALLE DEITCH-DIAMOND#900P F. ROOF SHEATHING, 7/16 PEL. BD A. INTERTHERM #AWY-024-B10 F. LIGHTS, (10) 2'X 4 r G. ROOFING' DURMAST 24,000 BTU AIR LITHONIA #2SPG-240-Al2-ES-120-PV 2,WALLS H. DRIP RAIL 35,000 BTU HEAT (1) PERCH MEI PROGRESS fP-5511 A. INTERIOR' 1/4' CHIAMON BIRCH I. 2 i/2'X 5'0' GUTTER @ EXT DOORS e30/110V-10-60CY, 43.3 AMPS G. TELEPHME OUTLETS' (3) B. STUDS: 2X4 IDZt STUD 16 ------- eurwmararmir H. HVAC DISCONNECT! 60A. FUSE C. TOP PLATE: DOUBLE 2X4 4.MIS_CELLANEOUS ALL DUCTING D. BOTTOM PLATE SINGLE 2X4 A. INTERIOR TRIM' PREF/NISHED COLONY OAK DUCTING - 8'X 2O' 10' TRANSIT/ON - 81 20' 111 8'X 16' - 12'L E. INSULATION' R-11 F. EXTERIOR; 1 X 4 BELT RAILS DUCTING - 8'X 16'X 26' G. BLDU ENG 16'TOP/ 12' BOTTOM END CAP - 8°X 16* H. SKIN .019 ALUM, (4) - BP x 8. DIFFUSERS WHITE ROGER 1F90-1 THERMOSTAT SYMBL WINDOW AND DOOR SCHEDULE , SYM, 1 QTY. DESCRIPTION THICK DOOR ' '' FINIS THICK! 1 R.O. SILL SW i HEIGHT' SING HARDWARE' REMARKS (7\ \r1; C LOSER 2 3'-0'X 6'-8' MTL, INSUL, DOOR W/ 5°W X 20'H VISION WINDOW, WOOD JAMB & BRI 1 3/4° PAINT CREAM 4 1/2' j 38'X 82' : I 1 LHR 0 YALE LEICKSET (LEM) #AU ',407-US26D STD. HINCES & f * 1 LHR ---- YALE LOCKSET OMB) Kr 5407 STD. HINGES & CIBSER 6 I FRAME FOR FUTURE 4 -t 4 A . 39' , IN • SULATED IND, SLIDER 4 1/2' 46 5/8' X 39 5/13' 36' 1 -- SYMBL ELECTRICAL SCHEDULE 1 I OTY DESCRIPTION EC..) — 1 2' X 4' TROFFERS i 1° LITHONIA #2SPG-240-Al2-ES-120-PV <> • PERCH LIGHT • 1 PROGRESS W-5511 $ 2 ME VAY SVITCH LEVITDN #1451-I t.11 6 MU OUTLET, NEMA 5-15R, HUBBELL #5262 16 1.401. 20 . 0 DUPLEX OUTLET, NEM 5-20R, ISOLATED GRUM, HUBBELL #IG-5362 4 3 TELERDIE OUTLET 0 3 INCTIal BOX * 1 DIRECT CD1NECT REV. NO. A DESCRIPTION . SALES: 2 S E. 56th ISSAQUAH, WA 98027 P.O. Box 1043 MOBILE (206) 392-1231 PRODUCTION: 14219 - 35th AVE. N.E. ft.IARYSVILLE WA 98270 (206) 653-.7577 • et.n.....mtnamamposswir ,...veromaamerwar SIN EVERGREEN COMPANY. DRAWN BY 1K APP RDVAL6L0 •1.- 3 • CHECtiED BY DATE 0 .119 NAME FLI (4, pp f1461 fa Li ;s10 DRAWING FL.004 Ht ti DRAW14+3 CANN9T REPROOMEO WITHOUT wil trrett coersem t voGivack MOStLE COMPANY PANEL 2A 100 AMP 2 vex 5'-0' GUTTER CENTERED OVER DOOR TYR JUNCTION BOX FLOOR PLAN. / BLDG, #2 /-- 60 AMP DISCONNECT SWITCH INTERTHERM #AWY-024B-10 ZA V 24,000 BTU AIR /- 35,000 BTU HEAT 230/110V-10-60CY, 43,3 AMPS RETURN AIR OPNG, 20'V X 12'H 100 AMP 208YA20 V. 30 7-- • POWER PANEL W/2" NIPPLE / & Slf.e X4' J-D(IX KESTREL e.USEPRiNT INCJ .1 ft, a ',. -..:- . ''' ...`7'...1. • v- r '. . ... ' ' ''%0 / 1 `'''' `" r '`' i . . ' ' ''.. .,,,,,,r.P.,, ,"* - ' * * ' '''.....4' ' '.. 4 o .,t• . , k. '''' * — ,P `''',. -. :..' ' ,-,.-``*^' '",..,.6.V '` -.. `.. / '',' '.';;-"*.■./.. ,. ..', ,. . . "..p ,.....*- : '• vs , ..-•._, . ,-,-, j • r; -. ..`e ',,,,-..,,, , .- 111111111111111111 I 1111 , . •,• ,...'" ' • ' --••• ",."' ''''''' • k " r, , ....,••■ :' • .4 0 .., 1 .".' .. -• , • . ,, ,,, '4 .:.:1-1 N‘. ...,,,, , t' •.. ,1.. .........,-1,.., ›.„.,,, . .)..',- r,.. _ '4.- ,,....., ' . ," -.• ..• '.:..„ t-'", ' , 77 .4.'1.... • '1- -'' %- - - -",,,, .„.., .., --; '. -, ,!..z.ti. , ;.4., , ,, 1 1 I I I 1 111 1- 1 1 . 1 1 1 1 1 1114P:111111111111111111111111f11111111111111111111111 11 I 1 1 1 11111111111111 1 I 1111111 4 5 6 7 8 9 10 11 NWEMERWANY 12 • mnyR! if tha mitsrafilmad Ailf.rimelnh .. Vo Lao. ,idanw 1.-h.... 4-1.s4 - • • • it DATE to JOB NAME .B0.5. it.441 f+ , LINE '# Z.;'1' i5 DRAwING Moor( mhta ouT g SALES: 22433 S.E. 56th ISSAQUAIi, W.A 98027 P.O. 80X 1043 (206) 392 -1231 PRODUCTION: . 14219 - 35th AVE. N.E, N ARYSVILLE, WA 98270 (206)653.7577 S/N i t e,9 SHT. KESTREL BLUEPRINT INC./ 130772 (c L M • (6) 2 1/2'X 5`-0' GUTTER CENTERED OVER DOOR TYP, SCALED 1/4° FLOOR PLAN / BLDG, #2 • u Ilil 1i1lllj 11 11III1I/I1II +I�I Iif j llt i1111I1I II1I1I1I1i111 1j11111iljliijlll11ll1l1l 1li1I1I1i1I1I li1lll1lli (I1I1I1I1III1III1III1I+ 1111111, 11llf1l1l1l11 11 /11III1I1I1Ill1lii11i1111111h 100 AMP 203Y/12.0 V. 10 PO E , PANEL W /2' NIPPLE & F X4' J-BOX 60 AMP DISCONNECT SWITCH INTERTHERM #AWY- 024B -10 24,000 BTU AIR 35,000 BTU HEAT 230/110V- 10 -60CY. 43.3 AMPS RETURN AIR OPNM. 20°V X 12'H T't":I•c;� fr1C t C. Nc i FURLI • M.EPHIINE CABINET V/ 2' PlIPPLE ' • 1 ELECTRICAL SCHEDULE t - SYMBOL - - j 0TY • 10 -. � DESCRIPTION 2' X 4' T;RIffFERS LIili1NIA B2SPG- 24O- Al2-ES- 120-PV r p � � L J _ 1 <�- P LIGLIGHT PRORC GRR ESS 3P -5511 $ 2 . ONE VAY SWITCH LEVITON 81451-1 6 HUBBEL DUPLEX OUTLET, NENA 5 -15R • C l • ° DUPLEX OUTLET, NEMA 5-KR, ISOLATED GM% HUBBEL 11G -5362 • 20 44 3 TELEPHONE OUTLET O 3 JUNCTION BOX DIRECT CONNECT KESTREL BLUEPRINT INC/ ,1707T4 0 1 L.t ;-s?' - 1G fiCo 1hI . 4 1 toC3`h! Cw'.„i ..+ I C7�✓ Post k ,y z NUMBER 2i C1(T. 1w. 1 3 7 11 13 .: 15 , 11 Z 0 000W I .5,c)t a' / r : ,....5 1.d, / c DUN. x { l D N. , „y REECE }} P , T. Ca DUPLE ♦.ECE,- i o 6 L3 1.EX. 4EPT .6 1tJPC. X ItECEPY 8: X RECEPT. } 1 E tPT, _. 10.0 LIGHTS - (3 DUPLEX RECEPT. ( 3} DUPLEX RECEPT. PARE SPARE SPARE SPACE V/8D1 E SPACE WHOWE SPACE,14 /IOWE TIUGUTS . a. W14H LOCAT' N AEL ;POST , Ii,I G: [RV SU G €BLDG. 2 LOAD DESCRIPTION , 2R SCALE 1/4' = 1' -0' \. l - - 100 AMP ZO6Y /!20 V. 30 / "POWER PANEL `d /2' NIPPLE .1 r g g X4' -Bfl X __ 60 AMP DISCONNECT SWITCH �-- INTERTHERM ##AWY- 0248 -10 . 24,000 BTU AIR V 35,000 BTU HEAT 230/11OV- 14 -60CY. 43.3 AMPS RETURN AIR UPNG. 20°"V X 12'H ELEC, LIGHT P�.AN / BLDG. #2 - TEL( p !-� N E C P 13 �✓'� FUR N, i`i O (4C TELEPH CABIY£T V/ 2' NIPPLE IIIIJIJIJIIIIIJIJIIIJIIIIIfIIIIIIII ;IIIIIII : I: II1IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII' tIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII f6 THS INCH 2 3 4 5 6 7 8 9 lo 11 MADE IN GERMAN{ 12 NOTE: If the microfilmed document is less clear than this Alta. Ain • • • REV. NO. DESCRIPTION JOB NO, 2.0s-1 DRAWN BY R CHECKED BY DATE t0:_ ;t JOS P1AME E5OS 3 3 C.&.: % t DRAWING LAC-11 PLAN THIS (MOO O CANNOT. BED FtErAOOUCED WITHOUT - WRITTEN CONSENT OF EYkRGPEEN UOtRE CO2MNY APPROVAL •- SALES: , 22433 S.E. 561h ISSAQUAH. WA 98027 PO. EiOX 1043 (206) 392-1231 PRODUCTION: 14219 - 35th PVc. N.E. MARYSVILLE, WA 98270' (206) 653 -7577 ' 7 I ` ik,7 K. . - 1st. : P . -n6 : ..:'_ (*TY P PLC:%S." : t ; 'j • t y. L _ , 'yam ; , . 1- +.a' a+. . j ... v 1 Y e1 x E .1, .' >._ JOB NO. Ci' I EVERGREEN MOBILE COMPANY REV. NO. SALES: 22433 S.E. 36th ISSAOU,4N, WA 98327 PO. SOX 1043 (206) 392.1231 PRODUCTION: 14219 - 351h AVE. IJ:E. - MARYSVILLE, WA 98270 (206) 5537577 DRAWN BY u APPROVAL .9 -- -7 j. TMF$ ORAVANfi CANNOT RE REPRODUCED VATHOUT WRITTEN CONSENT OF EVERGREEN MORIECOMPAN KESTREL pl.UEPRINT INC.! ,130772 F J �ilt�! ! !I! !I! !I! :�i!�!Ii�!i!�!I!�!I!f !I! !I! !I! ! I!l tlt�! Itl tit�tl !�!I!�t1!it1!�!I!�!I!�!It�! Its! i T1 1 1 1 1i 1t l! 1t► 1 1tltj 1 V ;! ��ji�! IililI�tlt�tl�� !Itltjt�►1t�!It�! 0 16TMSINCH 1 2 3 4 5 6 7 8 9 10 11 MAGEINGERMANY 12 OD ENSINRNMSWIliffiEfEad UMW SCALD 1/4' = 1' -0' WINDOW AND DOOR SCHEDULE SYM, QTY. DESCRIPTION DOUR FINISHI WALL R.O. SWING SILL HARDWARE' REMARKS THICK• THICKI HEIGHTI O 1 3'-O'X 6' 8° MTL INSUL, DOOR 3/4' PAINT 6 15/16' 38 X 82' RHR ----- YALE LIUSET ) ‘,// MU S'W X 20 °H VISION WINDOW, CREAM 540741S26D WOOD JAMB & BRICKMOULD STD. HINGES & CLOSER 1 • 3' -0'X 6' -8' MTL. INSUL. DOOR 1 3/4' PAINT 6 15/16' 38'X 82' RHR -- YALE LOOG T ODD) }1 v/ 5'W X 20'H VISION WINDOV. . CREAM KY 5407- US26D WOOD JAMB ' & PRICKMDULD STD, HINGES & CLOSER YALE 0063) 1 3'-0'X 6'-8' S.C. ka# )L Le-ei'a' -W DESCRIPTION �— .60 AMP DISCONNECT SWITCH INTERTHERM #AWY- 036 -B10- 35,000 BTU AIR 35,000 BTU HEAT 239/110V- 3 -60CY. 43.3 AMPS RETURN AIR OM 2$'V X 14'H Tai:; STRJCTURE MEE P€iX'fPER' is23 O l FwiD`.NG -TYPE • NO t G'. C: pANTe. t 4S( #LA T.t ON L r< I I i r R-30 wo11 0--11 ftoc R -11 Seismic Zone 3 JOB NO. /01 ..., DRAWN BY F CHECKED BY EVERGREEN MOBILE 4 COMPANY CONSTRUCTION 1938 Ursa BLDG , CODE .... OCCUPANCY. CROUP It, DESIGN LOADSS roof love•. 2•,ps wind tsar I iop taI 8O h- (exposur,e b). 3piift: 15p,c, f,l oor Live 50psf - 20001b. concoct tr 6t,ed: SALES: 22433 S.E. 551h ISSAQUAH. WA 98027 PO. 8OX 1043 (206) 392-1231 PRODUCTION: 14219 - 35th AVE. N.E. MARYSVILLE, WA 98270 (206) 653 -7577 JOB NAME I t521, ` DRAWING THIS DRAWING CANNOT SE REPRODUCED WITHOUT WRIT TEN CONSENT Of EVERGREEN EN MOSM.E COMPANY APPROVAL ii 6LO KESTREL BLUEPI UMT iHC./ ,130775 1 A 0 le THS INCH dim • mikagaumaamam 1' I11 ' 11 1 1f1 1J11' 1111111' 11f111J111 1' 1111Vl11111111111111111111111111111 1 1J11f t 1' 1 '1'1'11 1 '1' J '1' 111 11111 1 1 1 1111 111 4 5 6 7 8 1 1 1 9 10 1 1 ' 111111 11 11 PADEtN 12 HVAC SCHEDULE SHYDOL QTY. DESCRIPTION SHOEMAKER 0 104 PD-TIBD: (S ' 1 2 RETURN AIR VENTS SHOEMAKER 8 105' 24' X 24' V/ 12' DIA, NECK r i 1 L.. 10 FT k DU -. CT 28'V X 814 i L.. 25 FT LUCT - 20 X 811 r 1 , 26 FT to I .....■ Gt, , DUCT - 16'V X 8'H V/ END CAP. r L. 2 8 16'-6' I 1,1 , .. DUCT - 14'V X 811 V/ END CAP. 2 RUNS 16'-6' U rl , 1 L i I i — I h. (.1; 1 i . REDUCER - 211 X 8' TO 20' X 8' - 12 r-1 i 1 ,.....,1 1 LI i .- ' REDUCER - 20' X 8' TO 16' X 8' - 1E'LONG. 1 TFERMOSTAT - W'rlITE ROGERS - 11F901 V/ AUTO SET DACX & PlruGRAMMABLE. (SEE FlOGI PLAN FOR THERMOSTAT LOCATIOND SCALD 1/4' = • (13) - e X 4' TROFFERS 2' X 4' SUSMED ACOUSTICAL CEILING LITHUNIA 02SPfr-240-Al2-ES-120-PV V/ REGTICY TILE & DON 'DX GRID W•9 I/2' I Po. spcs) CROSS TEE WALL CHANE SUSPENDED CEILING SYSTEM NuT m SCALE RET1.RN AIR DUCT SIDS) DESCRIPTION VIRES SHALL BE SUPPORTED FROM ROOF RAFTERS V/ 2 1/2' SCREV EYES - 114' DIA. CLOSED EYE INT62THERM 44AV/Y-036-B10 35,000 BTU AIR 35,000 BTU HEAT 230/110V-4-60CY. 43.3 AMPS RETURN MR OPNG. 28'V X 14'H tormrsikainimmamonnewmai IMENERNISEINIESISEIRISIE REV. NO. BEM mogiagaISSMISEsmal Joe No. DRAWN BY CH ECKED BY ."' DATA JOB NAME ) 6. . THiS DRAWING CANNOT GE REPRODUCED VATHOUT WRITTEN CONSENT Of EVERGREEN AtO6A.E COMPANY SALES: 22433 S.C. 5 ISSAQUAH, WA 98027 P.O. BOX 1043 (20f) 392-1231 PRODUCTION: 14219 - 351h AVE. N.E. MARYSVILLE, WA 98270 (206) 653-7577 KESTREL OLUEPRIN• ,1307z2 9 10 11 ..14°E1 12 ENBOBEIRSI SCALE! 1/4' = 1' -0' FLOOR PLAN / BLDG. #4 WINDOW AND DOOR SCHEDULE SYN. QTY, DESCRIPTION IIIIIITHII FINISH* T -Y1 Ct R.O. SWING SILL HARDWARE! REMARKS HEIGHT* Q 1 3' -0'X 6' -8' MTL, INSUL. DOOR 1 3/4' PAINT 6 15/16' 38'X 82' LHR -- YALE LOcKSE7 4.EVER) W/ 5'W X 20'H VISION WINDOW, CREAM A!) 5407-11S260 WOOD JAMB & BR t(Q! CKMOULD STA ' S 8 CLOSER 1 3' -0'X 6' -8' MTL, INSUL, DOOR 1 3/4' PAINT 6 15/16' 38'X 82' RHR — YALE UEKSET XMJB) W/ 5'W X 20'H VISION WINDOW, CREAM KT 5407 -US26D WOOD JAMB & BRICKMUULD STi n USER tY.t YALE 7 a 1 3'-0'X 6'-8' S.C. MB DOOR 1 3/4' CQL 5 5/8' 38'X 82' RHR *1F 5401 -US26D d/ VIED ,IAMB o x STA HINGES © 8' YALE 1 3'-0'X 6'- S.C. 4ATC]D DU REV. NO. �-- 60 AMP DISCONNECT SWITCH r-- INTERTHERM ##AWY- 036 -B10 35,000 BTU AIR 35,000 BTU HEAT 230 /110V- 30 -60CY. 43.3 AMPS RETURN AIR WK. 28'V X 14'11 THIS STRUCTURE YYYE.ETS REOUtRELENTS OF THE I BUILDING TYPE:.; NO OF " OCCUPAi TS 1NSUL ;TI g 4vo 1 , 3 r ,. 1 f itior R -t d "isrrtr o11Q CONSTRUCT ION 98€. uN1 F •8LC1C : E- , -OGCtlpANC y 040 DES I GN -OAD • • 2Spsf :tlpl 14 i 10 ©r,` 1 I:,e; Z00014 , C.oncera�t t i# e: 4 APPROVAL U SALES: 22433 S.E. 56th ISSAOUAH, WA 98027 P.O. BOX 1043 (206) 392 -1231 PRODUCTION: 14219 - 35th AVE. N.E. MARYSVILLE. WA 90270 (208) 653 -7577 LO S. -3 KESTREL BLUEPRINT INC./ .130772 1 SHI$ DRONING CANNOT BE REPRODUCED WITHOUT WRITTEN CONSENT OF EVERGREEN MOBILE COMPANf GIONSZEINI :ks , =_t; . ti ,„� ,., f ° P _ . M.; yr . . f _ � - ... . . • -.., � ,.. i.. �, r .: ...;. A ._.. t � -. .�. ,. L�v> �' �z.,v'c: ,...::F ..+af'ie' �.. "Y . �.?`. 1' 1i 111111111' 111' 11J111j1111l111i1111J11'I •1JPJ 1 1 Ji1i1'1 1 1 1 1 1 1 1 1 1 1 1 ! 1 1 1 1 1 1 1 1iJ 1 1 1 J 1 1 1 1 1 1 1 1 ! 1 1 1 . 11i1iI11 111ili1111!1 1 1 1 ..1 t 1 1 1 ji1 1 1'1 1 16 THS INCH 1 7 '.; L Q (- 1t. 14 4; • REV. NO. KESTREL @ILUEPRIIVT MCI .130712 REFLECTED CEILING & HVAC PLAN BUILDING #4 SCALE, 1/4' = 1 (14) - 2' X 4' TROFFERS -- 2' X 4' SUSPENIED ACOUSTICAL COL/NG L ITHONIA 12SPG- 240- Al2- ES- 120-PV V/ REGENCY TILE & DOW 'DX' GRID - 8' X 14' RETURN AIR DUCT (BOTH surd) CROSS TEE -- WALL CHANNEL. 12GA. VIRE HANGER EACH FIXTURE CI R & 4' C. TYP. SUSPENDED CEILING SYSTEM NOT TO SCALE NOTE: mL..IP i DIFFUSERS To BE CII9ECTED Ti] SYSTEM FOR SETI4IC BRACING VIm I 515 CADDY CUPS. s t+:1 r u: HATA Aak TEE DESCRIPTION II IIIIIIIIJIIIIIII IIIIIIl JIIIIII, IIIIIIIII IrJ. Ll I' IIIIJIIIIIIIJIIIII IIJIIIJIIIIIII�IIifIIIIIIIIIIIIIIIIIIIJIII Iil. I IIIIIIIIIIII�IIilII jIIIIIIIIIIIIIjIIiIIIIIIIII 16 THS INCH 1 2 3 4 5 6 I 7 8 I 9 10 I 11 .ADENGERMANY 12 -- 60 AM? DISCONNECT SWITCH INTERTHERM #AVY- -036 -B10 35,000 BTU AIR 35,000 BTU HEAT 230/110V43 60CY. 43.3 AMPS RETURN AIR OPt+'G. 28' X 14'H SEISMIC BRACE 4 VIRES 2 45' EVERY 12`-0' O.C. i'-O' FRON TEE VIRt:S SHALL BE SUPPORTED F4 Riff RAFTERS V/ 2 1/2' SCREV EYES - 1/4' DM. CLOSED EYE EVERGREEN MOBILE 4- COMPANY DRAWING THIS ORAW ;NG CANNOT BE REPRODUCED WITHOUT WRITTEN CONSENT OF EVERO EN &IowLE COMPANY 9 SALES: 22433 S.E. 6th ISSAQUAH, WA 98027 P.O. BOX 1043 (206) 392-1231 PRODUCTION: 14219.35th N.E. MARYSVILLE, WA 98270 (206) 6537577 JOB NO. - y0 5-:. S/N 1 _ t24 DRAWN BY rt, APPROVAL 6LD 1 _38 CHECKED BY DATE JOB NAME 1 4 .' x ��,'. Gi: > -iC 17k-vt L, HT HVAC SHYBOL eTY. PESCRIPTI114 tut rut SHOEMAKER it 104 PD-UBD ', `"+'+ 1 •J (E." C. -, ,., ):( 2 RETURN AIR VENTS SH EMAKER B 195P 24' X 24' W/ l2' DIA. NECK 1 L — 19 FT ! . WALL.:: F.DUCT - 28'V X 811 i. _ 25 FT ? w. .t.< . DUCT - 29°11 X 811 t t [ - - 26'-6' - I st L C' DUCT - 16`V X 8'H V/ LID CAP. r L 2 f I Id , " s ' - T - ,14' X 811 W/ END CAP. RUNS Illie LONG • . rl 1 J 1 ritifil.I,FE,.RE R - 28'X8'TO20'X8'-12'I.01-ci. `J 1 ' ll`EL:,RE) Jft $ °29'X8' TEl 16' X 8' - 121246. � ` 1 THERMOSTAT - WHITE ROGERS - 9W90i V/ AUTO SET BACK & PROGRAN4A3LE. ( SEE FLOOR PLAN FOR THERMOSTAT LOCATDti) REV. NO. KESTREL @ILUEPRIIVT MCI .130712 REFLECTED CEILING & HVAC PLAN BUILDING #4 SCALE, 1/4' = 1 (14) - 2' X 4' TROFFERS -- 2' X 4' SUSPENIED ACOUSTICAL COL/NG L ITHONIA 12SPG- 240- Al2- ES- 120-PV V/ REGENCY TILE & DOW 'DX' GRID - 8' X 14' RETURN AIR DUCT (BOTH surd) CROSS TEE -- WALL CHANNEL. 12GA. VIRE HANGER EACH FIXTURE CI R & 4' C. TYP. SUSPENDED CEILING SYSTEM NOT TO SCALE NOTE: mL..IP i DIFFUSERS To BE CII9ECTED Ti] SYSTEM FOR SETI4IC BRACING VIm I 515 CADDY CUPS. s t+:1 r u: HATA Aak TEE DESCRIPTION II IIIIIIIIJIIIIIII IIIIIIl JIIIIII, IIIIIIIII IrJ. Ll I' IIIIJIIIIIIIJIIIII IIJIIIJIIIIIII�IIifIIIIIIIIIIIIIIIIIIIJIII Iil. I IIIIIIIIIIII�IIilII jIIIIIIIIIIIIIjIIiIIIIIIIII 16 THS INCH 1 2 3 4 5 6 I 7 8 I 9 10 I 11 .ADENGERMANY 12 -- 60 AM? DISCONNECT SWITCH INTERTHERM #AVY- -036 -B10 35,000 BTU AIR 35,000 BTU HEAT 230/110V43 60CY. 43.3 AMPS RETURN AIR OPt+'G. 28' X 14'H SEISMIC BRACE 4 VIRES 2 45' EVERY 12`-0' O.C. i'-O' FRON TEE VIRt:S SHALL BE SUPPORTED F4 Riff RAFTERS V/ 2 1/2' SCREV EYES - 1/4' DM. CLOSED EYE EVERGREEN MOBILE 4- COMPANY DRAWING THIS ORAW ;NG CANNOT BE REPRODUCED WITHOUT WRITTEN CONSENT OF EVERO EN &IowLE COMPANY 9 SALES: 22433 S.E. 6th ISSAQUAH, WA 98027 P.O. BOX 1043 (206) 392-1231 PRODUCTION: 14219.35th N.E. MARYSVILLE, WA 98270 (206) 6537577 JOB NO. - y0 5-:. S/N 1 _ t24 DRAWN BY rt, APPROVAL 6LD 1 _38 CHECKED BY DATE JOB NAME 1 4 .' x ��,'. Gi: > -iC 17k-vt L, HT RADI GUTTER 2.1/D`' X 5'-O' THIS ORAWIT'O CANNOT BE FiEPRODUCEO WITHOUT WRIT TEN CONSENT OF EVERGREEN MOaILE COMPANY REV. NO. INTSiTHEIN AVY--03 -B10 DESCRIPTION - :* %2 L11-11 ✓c JOS NO. 'Zp +-, S/N if t19 DRAWN SY 1 APPROVAL. CHECKED BY DATE I J 4 6. JOB NAME 4 15-2 O,9 DRAWING v ��- i.- V; VA-110H KESTREL BLUEPRINT INC.: ,130772 :l I Kamm .019' At " 16' VITE PORCH LINT .019' ALI/I SIDIi G I1J !!AST REEFING J - RAIL --` D( .AST R!? JflN ' J - RAIL .919' itUNN SIDING BLOUSING .019' ALUM 12' VIDE BLOUSING .019' ALUM - 16' VIDE PORCH LIGHT BLOUSING A19' ALUM VIDE tk AP CHU8''X8'X16' @ 6' Q.C. MAY CHU 8°X 8'X 16' @6' D.C.NAX J O ELEVATION BLDG, # 3 SCALE! 1/4' = 1 ELEVATION BLDG. # 4 SCALES 1/4' I111111111111111I11111111111111111111111111411. 111111111111i1111I11111111111111111II�illll 111111I1111111I111I111I1111111 111111 p1111I111I11111111111111111111111111111111111111 f0 TNS INCH 6 7 8 9 10 11 NADEINGERMANY 12 1 2 3 4 5 LT/101 T -.1 ..�..t3 I-. ...7 Li RAIN GUTTER 2 1/2' X 5'-O' PORCH LIGHT 3'-0' X 6' -8' INStL D4D. DR V/ 5° X 20' VISION VINDQV SEE DWR SCHEDULE INTT( AVY- 036-B10 F:7 fr COMPANY C: „:""" 1 i. l. 4 . 3' SALES: EVERGREEN 22433 S.E. 56th ISSAQUAH. WA 98027 • • P.O. BOX 1043 MOBILE (206) 392 -1231 PRODUCTION: • 14219 - 35th AVE. N.E. MARYSVILLE, WA 98270 (206) 653-7577 • i SECTION Scale! 1/2' = V-0' 5/8' TYPE 'X' GVB ( 2 LAYERS ) ,019 ALUM. am STD. ROOF VENTING Scale! 1 1/2' = 1'--0" EVERGREEN. MOBILE 4 COMPANY SALES: 22433 S.E. 58th ISSAQUAH, WA 98027 P.O. SOX 1043 (206) 392-1231 PRODUCTION: 14219 - 35th AVE. N E. MARYSVILLE, WA 98270 (206) 6S3-7577 THIS DRAWING CANNOT BE REPRODUCED WITI1011( WRITTEN CONSENT OF EVERGREEN MOBILE COMPANY KESTREL BLUEPRINT INC! , 130772 .. •• " "..- • . 5 , ,,,,„ ..?• -,' , •• •".4.,- •/' - . ' • -. ' ' ' ' "-'`''''' ..tki.. 7 i... ' . . ' ' .. ' /<*. .k111- ..... .,,, ... • , o- / •"- r s, : f : : ; VI ' ' , - ' , ,;*. • ..." : '' , • -. :1 f l" . t....4.;:..., 1 g ''''?";' I I I I I I I T I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 1 4 , 1 1 . 1 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I imp I; illIIIIIIIIIIIIIIIIIIIIiiII;;;IIITIIIIIIIIIIII 1 IIIIIIIIIIIIIIIIIIIIIIIIIiIII , .,,, s .v... , ...,, ..,$••■■ .47 „ :..,.. r Z." , ',/,`• • .;..., :r 0 la 71•IS INCH 1 3 4 5 6 7 8 9 in ii MADE IN GERMA/fi 1 °, It' . • • ]• m,r - i un_ yflpU[fl tS NUMBER 38 M3 'HAS 5 WIR LOCATION i POS 72, H.F.C. 2OSY/O '.'S SERVING BLDG. 3 100 AMP wflft MAtN PEAXER - — ------- — . I ; OM DESCRPTION — --- KVA -- VA - U- O. 0.2 O2 - , . . : KVA LARD 87 $ LIGHTS LIGHTS (SPARE . SP!kRE SPAR • • 'SPARE SPACE 14/HOWE . SPACE W/iiOW PACEW/ij .: . 0.8 . 0.2 . - - . .6_-oI-------------,- (1) 1G5362 RECEPT. (I) 1G5362 RECEPT. • • (I)IG-53(2 RECEPT.. SPNW .. SPARE . SPACE11/HOWE • . SPA W/HOWE • : SPACE I!fIE SPACEW/BDWE ,.,. I 2 8 10 0.2 . 0.9 •O.4 0.6 10.0 .W r, FLEX RECEPT. .(4)DtJpU1R . . #2) DUPLEX RECEPT. : (3 DUPLEX spAcE•&1HDwE . ,. SPAcl U/HDWE A/C tfl4U • . . . . 2 4 6 8 10 12 .. 16 FIB DUPL.EX OUTLET, 5-2R, IStIATED cJIB FILL 6I5362 - - - -- ---� I yflCtO g t 4 Nn2. N I ! >! ! i t' C,( t 011 OM SWIM Mk ow !poi 111111111110 1111111 •.as F M ‚ t CONNEC ED t OED I Z KVA 3 AMPS : -,--------- -- . EIE:: . .. J1CTIE1 B3X — . PANELSCHEDtJLE : • _i .A LOCATION AFL POS. 72, PU.C. SE1VNG BLDG 3 •' • . 20$Yf120 . VOLTS 3 PHASE 5 . WRE : AMP h MAIN. BREAKER • ------- ! -- LOAD DaSCRIPT�N -- VA - U- O. 0.2 O2 - , . . : I KVA LOAD DEacRtPrIoN 1 87 $ . 4 —. 0.2 Cl O ;2 - I . . . . - L :• .6_-oI-------------,- (1) 1G5362 RECEPT. (I) 1G5362 RECEPT. • • (I)IG-53(2 RECEPT.. SPNW .. SPARE . SPACE11/HOWE • . SPA W/HOWE • : SPACE I!fIE SPACEW/BDWE ,.,. I 2 8 10 •1b r (I) IG-5362 RECEPT. (1) IG-5362iECEPT. . (i),IG-5362 RECEPT. 'PARE SPARE . • ... ;PACE W/IIDWL ISPACE W/HWE . . SPACE W/HDWE P kCE E . 6 DUPL.EX OUTLET, 5-2R, IStIATED cJIB FILL 6I5362 - - - -- ---� I yflCtO g t 4 Nn2. N I ! >! ! i t' C,( t 011 OM SWIM Mk ow !poi 111111111110 1111111 •.as F M ‚ t CONNEC ED t OED I Z KVA 3 AMPS �SYHBOL Q TY €SRlPTI� r .— . iii 13 2'X4'TR1FtRS LIT13N1A 2S'E'G—c4C— Al2—fS -123 ?v -:::. 2 PtEHLIQT PRLXRESS P-5511 $ . 4 ivrrt 61451-1 10 DUPLEX EthZT, HEM 5—i HUBDELL5262 - �6. P 6 DUPL.EX OUTLET, 5-2R, IStIATED cJIB FILL 6I5362 - - - -- ---� I 1. TELEPURJTW ® 4 J1CTIE1 B3X — flCTECT PANEL SCHEDULE SThBO QTY DESCRIPTION 14 2' X 4' TRINFERS LITF[MIA 12SPG- 240- Al2-ES- 120 -PV p • 2 PORCH LI(BfT PROGRESS #P -5511 • ME VAY SWITCH LEVITt1 #1451 -I 14 DUPLEX PDUPLEX OUTLET, NEMA 5-155, HUBBELL 85262 1 2 SCALEI 1/4' = 1' -0' ELEC. OU ► PLAN / BLDG #4 V4g. � TYP.7 2' PVC . 40) 3 PL4CES 6 SI 4' J -f1X & Gi# NBIFKO 4A-6,6 1 1/2 4A -2,4 iiRiaDEMEDNZZESDKNESEED THIS RE M G CANNOT SE REPRODUCED WITHOUT WRITTEN CONSENT OF EVERGREEN moatE C^MPANY 60A SAFETY SUIT W /(3) RES. 45P ION 1/4' o MIER REV. NO. NUMBER LOCATION AFL POS. 72, N.F.C. 203Y/120 VOLTS 3 PHASE 5 4� 1111E 4A . SERVING BLDG. 4 . IOO AMP With MAIN BI;EAKER LOAD DESCRIPTION KVA E LOAD DESCRIPTION LIGHTS 0.9 0,6 (3) DUPLE?t RECEPT- 2 3 LIZHTS 0.2 0.8 (4) DUPLEX RECEPT. Q 5 SPARE 0.6 (3) DUPLEX RECEPT. 6 7 SPARE - 0,8 (4) DUPLEX RECEPT. 8 SPARE . - SPACE W /H&dE 1 0 11 SPARE - t SPACL 1 /HD !E i2 13 SPACE W /FIOWE 10.0 A/C UNIT 's 15 SPACE W/ HtY E . 1s. 17 SPACE N /HO's . ... is REMARKS CONNECTED LOAD 13.9 KVA 39 Amiss DEMAND LOAD t o ELECTRICAL SCHEDULE .1 & TAP 368' 60 AMP DISCONNECT SWITCH INTERTHERM #AWY- 036 -BIO 35,000 BTU AIR 35,000 BTU HEAT 230/110V- 143 - 60CY. 43.3 AMPS RETURN AIR OPNG. 28'V X 14'11 0 TEL, FILTERS) DESCRIPTION 5Le CTI JCAL, I RJ CALCUk4r!! - A1Z.4A= 14 72..3.e1.7 1235 W, 13 L16,Hi 6 S W = 110S" w 1105 C IZ :s EVERGREEN MOBILE COMPANY DRAWING S/N NO. s` . DAWN BY K /WI CHECKED BY KVVFa JAB NAM E Hai APPROVAL DATE .1 f / f 0 . SALES: 22435.4 56th IS AOUAH, WA 98027 P.O. SOX 1043 (206) 392-1231 PRODUCTION: . 14219 - 351h AVE. N.E. MARYS /ILLE, WA 98270 (200) 653 -7577 KESTREL 1 3LUEPRINT INC./ ,130772 c�l�.u^'�•n�,rie:.`��11 ¢S�C'ti�.tN.��7..F.;� � ,h Y` a Illl�llllll 11 , 1 1 !ll 0 16THS INCH 1 '.G 4 1f 111!1l11il1jallJ111 llllll1J!11 1111111 1111111 1111' 1 111 111111111!1 111 1111l11t'111'11 11111 1 1l 2 3 4 5 6 7 8 NOTE: If the microfilmed ducument is less clear than this 1111111111 9 iI1I 11 11l 10 11 MADE INOERMANT 12 SThBO QTY DESCRIPTION 14 2' X 4' TRINFERS LITF[MIA 12SPG- 240- Al2-ES- 120 -PV p • 2 PORCH LI(BfT PROGRESS #P -5511 5 ME VAY SWITCH LEVITt1 #1451 -I 14 DUPLEX PDUPLEX OUTLET, NEMA 5-155, HUBBELL 85262 �c�.IG i-\`-'''20 0 0 DUPLEX rJUfl T, t€MA 5-208, MATED GROUND F#1BBELL ItIfi-5362 4 4 TELEPHONE OUTLET 4 JUNCTION BOX ® 1 DIRECT ACT 1 DATA CABt - OU1't-s 1 2 SCALEI 1/4' = 1' -0' ELEC. OU ► PLAN / BLDG #4 V4g. � TYP.7 2' PVC . 40) 3 PL4CES 6 SI 4' J -f1X & Gi# NBIFKO 4A-6,6 1 1/2 4A -2,4 iiRiaDEMEDNZZESDKNESEED THIS RE M G CANNOT SE REPRODUCED WITHOUT WRITTEN CONSENT OF EVERGREEN moatE C^MPANY 60A SAFETY SUIT W /(3) RES. 45P ION 1/4' o MIER REV. NO. NUMBER LOCATION AFL POS. 72, N.F.C. 203Y/120 VOLTS 3 PHASE 5 4� 1111E 4A . SERVING BLDG. 4 . IOO AMP With MAIN BI;EAKER LOAD DESCRIPTION KVA E LOAD DESCRIPTION LIGHTS 0.9 0,6 (3) DUPLE?t RECEPT- 2 3 LIZHTS 0.2 0.8 (4) DUPLEX RECEPT. Q 5 SPARE 0.6 (3) DUPLEX RECEPT. 6 7 SPARE - 0,8 (4) DUPLEX RECEPT. 8 SPARE . - SPACE W /H&dE 1 0 11 SPARE - t SPACL 1 /HD !E i2 13 SPACE W /FIOWE 10.0 A/C UNIT 's 15 SPACE W/ HtY E . 1s. 17 SPACE N /HO's . ... is REMARKS CONNECTED LOAD 13.9 KVA 39 Amiss DEMAND LOAD t o ELECTRICAL SCHEDULE .1 & TAP 368' 60 AMP DISCONNECT SWITCH INTERTHERM #AWY- 036 -BIO 35,000 BTU AIR 35,000 BTU HEAT 230/110V- 143 - 60CY. 43.3 AMPS RETURN AIR OPNG. 28'V X 14'11 0 TEL, FILTERS) DESCRIPTION 5Le CTI JCAL, I RJ CALCUk4r!! - A1Z.4A= 14 72..3.e1.7 1235 W, 13 L16,Hi 6 S W = 110S" w 1105 C IZ :s EVERGREEN MOBILE COMPANY DRAWING S/N NO. s` . DAWN BY K /WI CHECKED BY KVVFa JAB NAM E Hai APPROVAL DATE .1 f / f 0 . SALES: 22435.4 56th IS AOUAH, WA 98027 P.O. SOX 1043 (206) 392-1231 PRODUCTION: . 14219 - 351h AVE. N.E. MARYS /ILLE, WA 98270 (200) 653 -7577 KESTREL 1 3LUEPRINT INC./ ,130772 c�l�.u^'�•n�,rie:.`��11 ¢S�C'ti�.tN.��7..F.;� � ,h Y` a Illl�llllll 11 , 1 1 !ll 0 16THS INCH 1 '.G 4 1f 111!1l11il1jallJ111 llllll1J!11 1111111 1111111 1111' 1 111 111111111!1 111 1111l11t'111'11 11111 1 1l 2 3 4 5 6 7 8 NOTE: If the microfilmed ducument is less clear than this 1111111111 9 iI1I 11 11l 10 11 MADE INOERMANT 12 ELECTRICAL SCHEDULE SYMBOL QTY DESCRIPTII,I 2 ' X 4' TROFFERS 11THONIA B2SPG- 240- Al2- ES- 120-PV Q 13 2 PORCH LIGHT P'OGQESS BP -5511 4 ONE VAY 3VITCH LEVITIIN B1451 -I E DUPLEX OUTLET, RENA 5 -15R, HUBBELL 05262 , IG DUPLEX OUTLET, NEMA 5 -20R, ISOLATED GR HUBBELL BIG -5362 6 4 j TEtfp10BBE OUTLET 0 4 - 1 JUNCTION BID( I -1-- 1 -4 DIRECT CONNECT 1 36 -1,3 lie (TEL) • i „ c. JOB NO. 2052- DRAWN BY g . REV. NO. DESCRIPTION S IN tr - i z.5 EVERGREEN MOBILE 4 .. COMPANY SALES: 22433 S 56th ISSAOUAH, WA 98027 P.O. BOX 1043 (206) 392 -1231 PRODUCTION: 14219 - 35th AVE. N.E. MARYSVILLE, WA 98270 (206) 653 -7577 TNt5 ORMING CANNOT BE REPROOXVCED W TKOs T WRITTEN CONSENT OF EVERGREEN MOBILE COMPANY KESTREL BLUEPRINT INC/ .130772 6'X 6'X 48' VIREVAY 1 306 TO 301(VA TRANSFORMER 60,4 SAFELY SWITCH V /(3) RES FUSES MEL 3A (RED POVER) VIREM LD 1 1/2'C-402 f 02 GRD, VIRENOLD *GG-4046B V/ FSIBBELL • BIG -5362 (5 -TYP. @ 5' -0' (IC, WIRFJBA) 0G- 4015D, TEE • iA SCALE' 1/4' = 1' -0' ELEC, LIGHT PLAN I BLDG, #3 2' -3' 1 1 SCALEI 1/4' = 1' -0' IA 1'C - THRU EXT. WALL FtR TEL) POWER FILTER PANEL 114I >312X- UL -3X60A ��.-- 1'C - 306 02/0 BARE CU GROUND VIREHEILD G-4000 DNIDED RACEWAY MISTING I)FI 06- 40008, BASE; 836 -4000C, COVER; 1640001, DIVIDER; 06-40 LITIG; 0G4010B, BLANK END FITTINGS; 0G -40011), DIVIDER CLIP @ 30' INTERVALS. t— 4' I VIR3 a ut @G-4046B V/ HUBBELL 0IG -5362 I I I LOCATE : ATH FILTER PANEL, 3 KVA ISOLATION XFI SV, 34 TO 120/208V, 30, 4V TI r •,#A.C330- 8T18H -ES / 1' PVC TI'l;U WALL TO 6'X 6 4' J -BOX / 4'X 16'X 1/4' COPPER RD BAR NOWTED ON GLASTIC INSULATED STAND -IFS. DRILL & TAP 3/8' DIA. HOLES @ 2' D.C. SECTION W SEE 'X 3'l( 4' J.:BOX (MIN. 61Z(E) .('OVER G u`R tBING) . POWER FR.-MR PAI 21, PANEL 3A(RED POWER) --- (DOA S AFE")'}'' a - M H w /(3) R+E*6 45 1115e5 -- 5' 6 "1 54r)X -- 010 /A IWL.ATcP TICA1,I5F00 TggPE.YitAC330- PANEL 3B(BLACK POWER) 30 KVA ISOLATION XFMR TIEMEY *AC330- 8TISH -ES (2 REQ'D) YXCJ..Fri'.G.Y : e''iRal iS iLi� 'Z� fia+ AEA 'SS +�w���L i:.1L�i'�C «�.esxesmMlwca :�aa � •.- ... -• � r ': .. - . n.: : : :. — II1I111l11111111'11l11 l�l 1 1 111111IIIIIIII1I41 1,111I11IIII1II III I1 j'IIIIIIIIIIIII1I1IIIIIIJIIIIII IIIII111111IIIIIIIIII 0 I6 THS INCH 1 2 3 4 5 6 7 27 PVC (S HD 4 TI4Ri:I W.ALt, CT (P ;C.P t..4 PURGES), TELEPIOZ CABINET 0134A 3R) ruco-os14.50 .13Y a QV ' C, (TOL) -6' MG 04110 PVC Q EAT, (E LIB 5105 Og FILTER. PAtJEL) IllEfinvX FILTER PANE t M (!♦.PTC 14650 W CI5) LTC- I ( O ' TELEPHONE FILTERS IIIIIIIIIIIIIIIIIIIIIIIIIIII . II . IIII . IIII'I , :.. 1n 11 MADE IN OERMA1JY 10 /-- 60 AMP DISCONNECT SWITCH INTERTHERM #ANY- 036 -B10 35,000 BTU AIR 35,000 BTU HEAT 230/110V- 10-60CY. 43.3 AMPS RETURN AIR cIPNG. 28'V X 14'H APPROVAL !CHECKED SY DATE, 1 11 i 0 $ f FOIE NAME - .clout ek Pi 1414T t 11q SHE : DRAWING .kT P' 1 fi H n c SHT. ELECTRICAL SCHEDULE SYMBOL I QTY . DESCRIPTION r " -- 1 U ■ 14 2' X 4' TROFFERS LITFA 02r240- AI2-ES- i20-PV' 1 <> a PIIicMH LIGHT PRESS *P -5511 5 ONE WAY SWITCH LEVITON 01451• I tt�- C 14 DUPLEX OUTLET, NENA 5-158, HUBBELL'#5262 0 D?,IPLU OUTLET, Nis 5 --20R„ ISOLATED GREMD, ERIBDEL_ 0IG -5362 44 4 TELEPHONE OUTLET ® 4 JUNCTION BOX DIRECT (ACT REV. NO. EVERGREEN MOBILE at COMPANY JOB NO. 2 SIN DRAWING SALES: 22433 S.E. 56th ISSAQUAH, WA 98027 RO. BOX 1043 (206) 392-12:1 PRODUCTION: 14219 - 35th AVE. N.E. MARYSVILLE, WA 98270 (206) 65:3 -7577 THIS DRAWING C HHOT BE RE3 W00UCED W'fHOU1 WRiT1 EN CONSENT OF EY!?RGREEN MOW::.E COMPANY DRAWN BY KK / wj r APPROVAL ~7_Q CHECKED BY wi3 DATE ! I i d � .a0 / 8 . JOB NAME e, r: SE T FLtf1HT L t E 514E " ' NEMTREL BLUEPRINT INC./ ,130772 SCALE: 1/4' = 1' -0' ELECT LIGHT PLAN / BLDG #4 8`X 87 4' J-BffX (POVER & G4 VDD 2' PVC (ScHD 40) 3 PLACES ----- PANEL 4A 1 i/2'C -442 & #2 GM \oa SNITCH FUSES TELEPH 1E CABINET (64A 3RD FLig.t4 FBI! l: r -t1.14, A--- -- B t5") FOX •,t" C - 3t4 J INTERTHERM #AWY- 036 -D10 35,000 BTU AIR 35,000 BTU HEAT 230/113V- 10 -60CY. 43,3 AMPS RETURN AIR OPNG. 28`V X 14'H TELEPICNE FILTER PANEL .. LIII RLPTC 18X1650 (10 TEL FILTERS) — PUVER FILTER PANEL LPO BLPX- U.. -3X60A 30 KVA ISOLAI 1 Xrt 480V, 30 TO 120/208V, 30, 4 \TIES Y DAC330- 8T1811-ES a'.tii: 3S::2Cb'?�i H.u t��I:k3i9t3i4'.WC14i .'9' moN:��7ii '` '%fak9u'�. 3$161 { 'L+l:Is'3k .ou,w vzia. _ ».�. . II IIII IIIIIIIIIIIIIIIIIIIIIIIIJIIIIIIIIIIII• J II{ 11 IIjIIIII IIjIIIIiIIIIIIIIIIIIIIIIIIIIIiIIIIJIJIIIII! IIIJIII�IIIIIIIIIIIIIIIIIIIIIIIIIIIII IIiIllililIII I llllllllllljI II IIFIIIIIIIIIIIIII 0 ISTHSIN.H 1 2 3 4 5 6 7 8 9 10 /-- 60 AMP DISCONNECT SWITCH 4'X 16'X 114' COPPER GRD BAR tOJWTED UN ELASTIC !MATED STAND -OFFS, �. 1 DRILL, & TAP 3/8' DIA. HALES 2' PVC (SCHD 40) 3 PLACES 1 1 MADE IN GERMANY 1 f osAYMYEAN kr Ate $40NAt- Sri' J 1 48' WAINSCOTE OF q F.R.P. GLUED DIRECTLY TO I/4" N PANELING (TYP. 2 PLCS. AS SHOWN)----, I /4 " -= I' SCALE REV, NO. EVERGREEN MOBILE COMPANY JOB NO. 2034 DATE JOB NAME 14 X 24 WASHCAk SHT. BOEING DEVELOPMENT CENTER 1 DRAWiP�G F;..O0t1 & NV . P AN SALES: 22433 S E. 56th ISSAOUAH. WA 96027 PO. BOX 1043 (206) 392-1231 PRODUCTION: 14219 - 35th AVE. N.E. MARYSVILLE. WA 98270 (206) 653-7577 SIN IC 9 APPROVAL 6LO 1 _is &5 TN&S DRAWING CANNOT BE REPRODUCED WITHOUT WRITTEN CONSENT OF EVERGREEN MOBILE COMPANY FLOOR PLAN 38" X 82' MTL INSUL. DR. W/WD. FRAME 13/4" THK. DOOR: CECO ENTERGY SERIES 100 ESMI BRICKMOULD: CECO 22 SERIES WD. PROFILE THRESHOLD: 6 3/I6" THK. JMB. PEMKO # 172 -A 36" SWEEP: PEMKO # 315 AN 36" WEATHERSTRIPPING: PEMKO # 305 AR SET HINGES: McKINNEY # TA- TB3313 4 1/2" X 4 1/2" N.R.P. 11/2 PAIR CLOSER: CORBIN # KPI20XD- SBL -SNB COLOR: CREAM LOCKSET: E -Z -SET # BP- IOOT- SN- -US32d STAINLESS STEEL 38 °W, X 82" H PRE -FIN. COLONY OAK DR. W/WD. JMB. 13/8" THK. HINGES: McKINNEY # TA- TB3313 4 1/2" X 4 I/2" N.R.P. 11/2 PAIR LOCKSET: E -Z -SET # BP -• 10 I T-- BA -US3 POLISHED BRASS GREY WATER TANK 165 GAL 38" W. X 82" H. 38" W. WALL X THKNSS. 82" H. 6 3/16" I -RHR I -LHR i -LH. I -RH WALL THKNSS 6" DOOR AND HVAC SCHEDULE R.O. REMKS. SYM. QTY. DESCRIPTION 4 F SENTINEL FAN FORCED WALL HEATER 1500 W. 120V. # WHA- {512 SEE WAINSCOTE NOTE NOTE: SEE PLUMBING SHEET #4 FOR FIXTURE DETAIL NUTONE THRU THE WALL EXHAUST FAN C/W HOOD WALL STYLE II5V 60 CY. - 1.5 AMPS METAL TOILET PARTITIONS TYP. -IVAC PLAN 1/4" = I' SCALE L_ SENTINEL FAN FORCED WALL, HEATER 1.5 KW. # WHA -I5I2 TYPICAL AT 4 PLCS. DESCRIPTION '41 8" THRU THE WALL NUTONE EXHAUST FAN # 8870 TYPICAL F AT TWO PLACES KESTREL BLUEPRINT INC./ .130? ?: • 1 C 16 THS INCH 1 .y...,.._...w...i�',r i . .t- &y.. x..d�,✓dlY.� '' rTS» i.�. .: .. ". .: , '' 1 ; . . ��. � c. � v , - R. , �, `^ r "p• �,.n - � . .a' _ f p � '�, . �� . r f y�i' 2 f y .;s ;su 7' '-� �s 1,0. II IIII I IL IJiJIIIIII ^ Ifiij I�III��IIJII��IJI`II �a. l�' T' IIJ�I�IIIIJIJIIIIiJIII IIIIJIII'IIII I IIllilliII III III ��II�!t IIIIiIlIIIIIi�l��II It I�1;�i�l l I; �I�II� ►IIII!I�I;�iIIIIII�I'III�III 2 3 4 5 6 7 8 9 10 NOTE: If the microfilmed document is less clear than this 1 1 MADE IN GERMANY 1 • • DESCRIPTION JOB NO. 2034 DRAWN BY C A W CHECKED BY D W P S/N I0 : 9-114' APPROVAL DATE 11 -89 "B NAME I4," X 24' WASHCAR BOEING DE VELOPMENT CENTER DRAWING SECTION SHT. F THIS ORAWIttG CANNOT BE REPRODUCED WITHOUT WRITTEN CONSENT Of EVER. REEK MOISILE COMPANY DATE T OR TOP . , Y1v5U:: OR EAr c.u{tx s es .4-.242z.1 TT4 "t7u}SAtec.P . _ q� 'W I {YO . CO U ,r_ = f f I ( t'-G4 0 PS A LUK 0I48riW8WEO ROOF VENTING STD. RENTAL END DETAIL TOP HORIZ. BLOUSING DBL. TOP PLATE BOTTOM HORIZ, BLOUSING. --_____ ' Mr` 1 x` DRIP FOR VENTING SEE FOUNDATION DWG . --- • 0-4 r ft o ft - r,r ---- _.-, VINYL-MOULDING VAPOR BARRIE 4 . GROUND LINE t . liiiilii ii7440Q i i iiil i EXTERIOR WALLS — I /4" PRE — FINISHED CINNAMON BIRCH PANELING C. TOILETS AND URINALS. 4' WAINSCOT W/ FRP IN ALMOND — 2X6 STUDS @ 16 "•0 /C. — -19 INSULATION — 7/16" PELICAN BOARD — .019 ALUMINUM SIDING CREAM SECT 1O 3/4" = i' SCALE FLOOR .44 --- _WOOD S H I M 8 "X 8 "X 16" CONCRETE MASONARY BLOCK X' 4e, CONCRETE PA F- VINYL — ARMSTRONG # 86501 j BIEGE'SEAGATE — 3/4" T & G PLYWOOD - 2X6 JOISTS @ 16" 0, /C, - R —I9 INSULATION — 7/16 PELICAN BOARD R. I AS t !t1Y .t Mttt St X11 Rif 5Il 0I4VIOR '$! � 10 1 BEAM. CEILING — 1/2" MOBILE SPAN — 7 16" PELICAN BOARD — 2X8 NO SLOPE @ 16" 0 /C. — .-- 0 RIGID INSULATION — IX4 VENT.SPACERS @ 12" 0 /0. — 7/16 PELICAN BOARD — DUROLAST ROOFING III 12" 12 CROSS ANCHOR — HOLD DOWN 2500 LB. WITHDRAWAL. CHN.t t:,c ?o P>awnr r 141F7F,P, 11 Tip I CAL I NT. NOT TO SCALE 1/4" PANELING 48" WAINSCOT I N TOILET AREAS 2X6 STUDS @.16" 0 /C. 1/4" PANELING PREFINISHED METAL SKIRTING KNEE BRACE FOR SKIRTING 0..4-0" 0 /C. PRESSURE TREATED WOOD 1 1/4" X .035 STEEL TIE DOWN STRAP 4750 LB. TENSIL STRENGTH I) 1 EVERGREEN MOBILE 4 COMPANY ER I OR WALL SALES: 22433 S.E. 56th ISSAQUAH. WA 9802 P.O. SOX 1043 (206) 392-1231 PRODUCTION: 14219 - 35th AVE. N.E. MARYSVILLE, WA 98270 (206) 653.7577 KESTREL BLUEPRINT INC./ ,130772 y . V:n..fxr1.. « «- :..q.w >.t+: i.1.cs2..cr v,,,l .u......a6,w+.u'< X74+ s�.: ��Lc .dw..s',.sA.w"��`"'a�.:,F4.,.� css.r3•...1 ,c f °. � .�^,;.�� ,�; .3e ? .* - r -N••t - ��?. , I .m...� 6. .5�«; �fSEtr�� ' �i:ulfii:Y�:}-Y `' ��.. +�� t i �',,� ti � r:� x.r ..;u:i:.....•`7 , .:�`re'�'�sS ��aaa� 1111�1II 111111111111111111111111111111111 I 1. 11, 11111111I1111111J1111111111111j111111111I1111111I1111111J1111111J1I11l 11i1111111I11111I 111I1111111111111I1111111I1111111I111111111111111I11111111 0 I6THSINCH 1 2 3 4 5 6 7 8 9 10 1a /1•717 11 MADE INGERMANY 12 -PANEL SCHEDULE - PAN L N t !. .. - LOCATION • ° ' =a R a., i''.,tl ti VOLTS t c PHASE k „CY t ai AMPS MAIN F CIR. DESCRIPTION III I1' " ^Tli , ,` 8RK l+ +Try =Y +i A $ CIR.DESCi2IPTION � IIVIIIIIM I - ' wo. 1 1011011F1:11 -- - - ° t. -I_ a - .1 d iS Co IIIITLIVOICZSMI �, i I��� .. MIN rillionsillale= - M �� _ tom MI 1010101101111110110 CONNECTED LOAD. DEMAND LOA D, t 36 WATTS /03. AMPS. t tr AMPS I, 5 �-- ��.f7 soQ 7�a • DRAMIN EY DRAWING ELECTRICAL PLAN SHT. THIS DRAWING CANNOT bE REPRODUCED WITHOUT WRITTEN CONSENT OF EVERGREEN MOWLE COMPAN'i OF G N07 £S: ,(j E. 12' �\ 03 e 1.0 !timber . is not inteideil to Identify a specific ::3rcuit breaker or location ins1 the load center., but to identify like circuits only. . Circuits shall be balanced between phases u near es • • possible ias, accordance with N.E.C. sections 220 -3(d) itEIO FACTOR:: - J -- Tights • '.gip. Ft. X 3 watts X Sq. Ft. X 1.25% Receptacles a Qty Z 103 Watts X 100% For Irst 10,000w remainder at 50X (table 220-13) • 1 ELECTR I CAL PLAN /4" = I SCALE 15 Rap : 114 CU 2fi lw�p-112CU • 30 Rea - 110 CU Resistance Neat 9.1.03% (Table 220.20) katts Volts + Amin Vales X Amps ■ Watts AfC. 1.00% (Table 2202.35) N For 3 0 �.V • AmPs Appliance Moto X 1.2SX (Table 430150) ,Oaf. GFC r o ] a� 14 . g. , air °. MO T - d3Ar 1 - o 6 do W it IBM �000�, coo -. ELECTRIQAL AMP FIAT N I ' DE SCR I P'TION AC"T L CALCULATED DE.1141 0 LOAD! we LOA 01 NIG Fs rt R 8w g�O1 t:° PTO o w qoo W. 1.0, 1.0 00 1 0 HO TOiA.L LOAD 10..22. 12 8 .. _TOTXT. 120 . GENERAL HIRING SIZE l�PER. 60 Amp #4 CU 90 Atp f2 CU I2• REV. NO. ELECTR I CAL LEGEND 4 8' STRIP SURFACE MT. FLUORESCENT LIGHT # C240 —ES W /40 WATT TUBES ►} 2 PORCH LIGHTS MARCO # 8 -2 W /I00 AMP BULBS 5 GROUNDED DUPLEXES LEVITON # 5248 -1 IVORY COLOR. [5] PLATES LEVITON # 86003 IVORY COLOR. I GROUND FAULT INTERRUPTER DUPLEX LEVITON # 6599 —I IVORY COLOR W/ PLATE 8 SINGLE SWITCHES LEVITON # 1451 —I [•4] 2 TOGGLE PLATES LEVITON # 86009 IVORY COLOR. 1 125 AMP ELECTRICAL PANEL 120/240 V. 10, 60 CY. UNDERGROUND SERVICE. SQ. D. # 00-20L-125 WITH COVER Q0 6 DIRECT WIRE UNITS DESCRIPTION DATE I . • 4 EVERGREEN MOBILE 4 COMPANY JOE NO. . , s SIN . I SALES: 22433 S.E. 56th ISSAQUAH, WA 96027 P.O. BOX 1043 (206) 392 -1231 PRODUCTION: s 14219 - 35th AVE. N.E. MARYSVILLE, WA 93270 (206) 653 -7577 CAW APPROVAL CHECKED BY D1 DATE I 4-e - JOB NAME 14x 24 WASHCAR BOEING DEVELOPMENT CENTER KESTREL BLUEPRINT INC.! , i3O7ta 1 .'. x. �:......,«.., st%' �.. �. w: N . v �......' 3" i,..' r:.'�.'�::t.a..'�ii'ar:.Ct�!"L: Jess-'/. �.>: ONZ' Y91�e". 1G�i, id� . $J�''0�{GSG7b G. i ,s Ei . .. �� v . � � ... �' ` !. .� '' 1S �. °n"{. .S,Y 1.:l y ,�?'. .. �M'2',. i ..sm .. ��b'yy�������������� • ;C;[+'S''' : " -. iC (y ,( .: . V.Y . � ....!.LQY'9Rlfi,55fdP#i�'�Aum !eFN4'2 Pa?.ri1 :Tti IIIIIIIIII II IIJIJIIIJIIIIIIIIIIIIIIIIIIII II. II`�IIIIIIIIIIIIIIIIIIII!I IIIIIIIf IIIJIIIJIIIIIII ' i,ilI II Illlll�IIIIIIIIIIIIIIIIIIIII,! iIIIII IiIIIIII�III�I IIIIIIIIIIIIIIIIIIIIIIIIIIIII 'II IIII 2 3 4 5 6 7 8 9 10 11 MACE IN GERMANY 12 O 16THSiNCH 1 y IBBIEMESMIBMBIII MOUNT ON WALL ! \`' u .,;: . � p , WATE" LE1fr �L , ` - ,l: : - i 4 /2 " \ \ '„& V ; • GA L. WA . �\ 1 p� I . ON SHELF (CURE - TO WALL W/t STRAPS j 1 ( 1 v 8. CL ! P TO }IEEE O 4'.-------- BA \E) 1 1 17------N NOTE: ALL SEWER LINES ARE GRAVITY FLOW DOWN TWO INCHES TO TANK. 3' KNIFE A 2" V.T.R. PUMP \ 3" CAP & CHA MOUNT ON WALL.- 3/4: CW ./ FLOAT .,.. VALVE T° MARINE TOILET INAL). I I/2 P —TRAP 2 " CLEAN OUT CAP & N/ WASTE • ISOMETRIC 1/4" = I' SCALE GENERAL NOTE I. THE 1988 U. P. C. APPLIES. 2. USE SCHEDULE 40 ABS /DWV PIPE WHERE NOTED. 3. ALL LINES ARE GRAVITY DRAIN SLOPE TWO INCHES TO TANK. I I P —TRAP 3/4_ CW 3/4" APPROV FLEX LIN CONNECT )N WALL I/2 " FLEX HOSE 3/4" GENERAL NOTES : 1. THE 1988 U. P. C. APPLIES. 0 2. USE COPPER WATER LINES TYPE 'L', 3. CLEAN ALL LINES EXPOSED OF SOLDER FLUX. 4. USE ESCUTCHEON PLATES ON ALL WALL JOINTS WHERE EXPOSED. 5. USE SHUT OFF VALVES ON ALL FIXTURES. 3/4" SHUT OFF VALVE I /2" 3/4" CITY WATER INLET CAP AND CHAIN REAM PIPE OUT LAV / smasmsskommagessiBIBBIBIZI REM THIS DRAWING C KNOT BE REPRODUCED WITHOUT WRITTEN CONSENT OF EVERGREEN MOBILE COMPANY EMMEN REV. NO. s' DESCRIPTION ^M CW RN VENT .TRAP MAKE & MODEL ' QTY 1 FLR. Mr. WATERCLOSET 3/4" - 3" f t /2" RAJITAPI HOUSEHOLD SIZE PHFHRII - I15 V 2 WALL MT. URINAL 3/4' - 3 2" AMER. STD. � 8.581.017 � ; lab URINAL FLUSH VALVE 3/4 - .. - SLOAN $ 186 1 HOT WATER HEATER 3/4 3/4" - - RHEEM ! 84-S i MI 1 EA. 42" 8 3Q` GRAS OVAL LAVATORY - - . 1 f /2" 1 1/2" BRIGGS LAVATORY FAUCET ! /2' 1/2' - - MOEN $ 4896 -A W/A4TL WAST 2 3002 2 Ei�oS STD. ! 2 SET j r'7 TOILET PAPER HOLDER - - - - McK 1 NNEY WASTE TANK PAPER TOWEL DISPENSER - - - - MCK i,N'NEY 3" - MA.R i NE SAM I . SPEC, #W --5lsl 1 605 I 2 I (�32 ! 2 - - I 4] LIQUID LEVEL CONTROL - - - - SJ i01 PWf- -I IS V. ! liti I B "X 36" MIRRORS — - EMCO STD. W /CL ! PS 2. 1 — - -- - -- — t ! , WASTE ELEVATION NOT TO SCALE DESCRIPTION TANK 13 I /2" PLUMBING SCHEDULE EVERGREEN MOBILE 4 COMPANY JOB NO. 2034 DRAWNIR . MPPROVAL6jj CHECKED BY D W P DATE i 4 89 C1s NAME ! 4 X 24 WASHCAR ... . BOEING DEVELOPMENT CENTER Df AW1NG P r - A SALES: 22433 S.E. 56th ISSAOUAH, WA 98027 R.O. BOX 1043 (203) 392 -1231 PRODUCTION: 14219 - 35th AVE. N.E. MARYSVILLE, WA 98270 (206)653.7577 KESTREL BLUEPRINT MCI , 1±0778 1 iXiXfflS 1III1LII1III1III1III1III1III1IIJ 11111111111I1L11111 ) 16 THS INCH 1 2 3 0 16 THS INCH ;�.a� #;fir a^ 4� i.:.n . tc „., :r. r � 7 n�.0 <w /1 � 1 11 1!11!1 11111'1 1I 11 1i1111I1ij1111111111111111 9 10 1 1 MADE IN GERMANY 12 DESCRIPTION REV. NO. KESTREL BLUEPRINT INC.! 12421g CLEAN OUT CAP & CHAIN = i WASTE PLAN 1/4:= SCALE T1? I WASTE VALVE UNDER UNIT W/KNIFE DUMP, " CAP& CHAIN I I i r-o v 3 VENT T"RU ROOF • 1 &2.T_ 4) 3" I3ENU STREET I/8 2) 3" COUPLING 2) 3" FEMALE 1- 00r; FLA:E 2) SX 3 NIPPLE (1`siIPT X GRENTEC I003 GATE IvALES 2r) 5 VENT PPE 2) 42:X 27 10 P012 1-40!..1;1 t i TANKS NEL. ALL SEWER LINES ARE GRAVITY FLOW DOWN 10 BLACK WATER TANKS_ GENH2AL,NOTES I. 1988 U. P.C. APPLIES- 2. USE SCHEDULE 40 ABS/DWV PIPE WHERE NOTED. 3. ALL LINES ARE GRAVITY DRAIN SLOPE TO TANK. NOTE: THE SEWER DROP MUST EE A OF 3" FROM ALL PAM'S OF THE STRUCTURE ; I I BLACK 0 -Li ' ._ •..__•. • . • ._ _ _ • • ELF\ATION 3I8 I SCALE VENT THRU ROOF BLACK. VITIR VENT THP1JPOO O t :i1 it 1: ;1" 11 11 .; ;• ;1. 1 :I - 1■IEW [BLACK 11" • 3" INLET F. PT ' VENT THRU ROOF (NEW) ROOF FLASH iNG 1 V TR. (EX ?STING) ROOF FLASHING ISOMETRIC OF VASTE NOT TO SCALE 3 41; cAL. cAP. SDE HOLDING TAW CALE EXISTING BLACK .-4VTR TANK STILL t ----1 IPR URINAL & ■ P•11414 • " ` .."1 " • , • 0 16 THS INCH 2 • 3 4 5 6 7 8 9 10 11 MADE IN OERNIMY 12 VTR. (EXISTING) 1ST IN G) ROOF FLASHING cI „BLACK . JOB NO. 2034 DRAWN BY • A w. CHECKED BY DRAWING Nikr A STE PLAN I t' T R. (N E VV) ROOF FLASHING BOLT TO f:p(0 JOIST 26 GA STEEL STIRAPS.C( sie DA. X 2 BOLT —2X2 PLACED SO TANK SLOPES TO DIVA NOTE: FRAME AROUND HOLDING TAW A TO PROTECT /' (31 NT ,,/ F. ET t ., INL ET 4 5 64 L C AP. LEFT SIDE HOLDING TANK 314 SCALE EVERGREEN MOBILE COMPANY THIS DRAWING CANNOT 8E REPRODUCED WITHOUT WRIT TEN CONSENT OF EVERGREEN MOBILE COMPANY SALES: 22433 S.E. 56th ISSAQUAH, WA 98027 PO. BOX 1043 (206) 392-1231 PRODUCTION: 14219 - 35th AVE. N.E. hiARYSVILLE, WA 98270 (206) 653-7577 S/N 1069-104 APPROVAL 61 7_3 85 DATE 12_29_89 JOB NAMEI471/4724` WASHCAR SHT. BOEING DEVELOPMENT CENTER OF 6 REV. NO DESCRIPTION SALES: 22433 S.E. 56th ISSAQUAH, WA 98027 P.O. SOX 1043 (206) 392 -1231 PRODUCTION: 14219. 35th AVE. N.E. MARYSVILLE. WA 98270 (208) 653.7577 $,Weci* O Itioe'tate Wit swil M t b a c t r kaes bctloae s f asd t, tsso. Furl alit aa+cst ks achieved a '. • Smicsi Iglesias Heed: lied 33'x 3/4" iti Tonsil steed reds ere sgptled ' ' loth each £2Ch t. S au ootoo , st o4 FOUNDATION PLAN 1/4" = I' SCALE STRAP BOLT fe WI .d qle iself a r %aa B .. . so, -.q art Ur xfu gag Ws +.acts, ao w.. w =KM a,e sows ,,4& of I t.. - Ras aaioc ce6fl.u. 11.6 76x.►i4 amt. is Ys as lw aw vma t,.c ac►vaa NOTE: VENT CALCULATIONS FOR GENSCO # F--8I5 336 SQ. FT. — 150 = 2.24 2.24 = .52 =.3.69 OR 4 VENTS. GENERAL NOTES: f. ASSUME 2,600 P.S.F. SOIL BEARING PRESSURE PER U.B.C. 2. SET 8 "X8 "X16" CONCRETE MASONARY'UNITS CONFORMING TO [988 U.B.C. SECTION 2402, IN STACK DETERMINED BY ELEVATION AT SITE. ALL STACK BLOCKS OVER 3'--O" IN HIEGHT SHALL BE SOLID GROUTED SET ON 3'X3' CONC. PADS 6" THICK. 3. PLACE WOOD SEES ON TOP OF CONC. BLOCKS TO LEVEL MOD 4. TIE DOWN STRAPS SHALL BE TYPE 1 CLASS BE GRADE I • STEEL STRAPPING 1 I /4" X .035 CONFORMING WITH FEDERAL SPEC. CIO--S- -781 —H WITH MIN. BREAKING STRENGTH OF 472818S. 5. NUMBER OF TIE DOWN STRAPS IS BASED ON 20 P:S.F. — 80 M.P.H. FOR A DURATION OF ONE DAY EXPOSURE B. STRAPS ARE BASED ON 3,150. LBS. AND CONFORM TO ANSI 119.1 N.F.P.A. 501 B C.F.R, 24 PART 230 WAC 296 -48B. JOB N0.2Q DRAWN CAW CHECKED BY D W P - DATE . 11_ 4 _ Job NAME, 14 X 24 WASHCAR SHT' BOEING DEVELOPMENT CENTER • e KESTREL BLUEPRINT INC./ .1$0772 . .. .. .- :.> r .. :,., a. r�1 .- ..> . - -. x .. .. ri:•; . ,. i_,, > e. E. . "F g r f l roY�`: .,... ., ., .o., iw+' Ju"" G�1�7`itY�{LkY�i.L�l '�'� Y n, k �•- y,,,liy.�,, - �.(..rs`.✓�S' ' y�XiL�y,`,. ; �., .. .0 . r ° . r .ar� a. ..... ,:a'•..> -.'_ ...i �: c�' i .:., ..c... - . ^s: .�L ;: � fL�G3GR $'/�.'�( =. ��n;,� _ �_{,f� . IIl1II!lI1I1I1I1 1 1!!1!111' 1.111 1111111111111111111111111111111111111111 !11 1 11111I1f 1I11!III!I!11 !!11!11 111111 1 1111 1! 111'11, 1111'1'11111 11111 !1111111!1'111111I111111�j1I 0 16 THS INCH 1 2 3 4 5 unTT, Tf the 6 7 8 9 10 1 1 II0EINGERi4AHY 12 mirrnfilmnd Anrmmcnt is 1nen r1nnr Flinn this DRAMMNG EOUNDATI N PLAN TN1S DRAWING CANNOT BE REPRODUCED WITHOUT WRITTEN CONSENT OF EVERGREEN MODILE COMPANY