Permit 6580 - Easter Residence - New Single Family Residence
z ;c MEMORANDUM OF MEETING Meeting between Duane Griffin, Building Official, and John Easter, 12/10/91: Mr Easter's building permit expired. As a result of my letter notifying him of the expiration, he requested this meeting to see what would have to be done to reinstate the permit when he obtains financing. I explained that the plans would have to be changed to meet ; the Energy Code and the Ventilation & Indoor Air Quality Code. It was agreed that if the actual structural part of the plans would not be substantially changed he would be charged only half the original permit fee and half the plan check fee when he resubmits, if he resubmits the original plans modified to meet the current codes. He also said he owned two lots side by side and there was a person interested in buying the lot that this set of plans applied to. Mr Easter wanted to know if he could use this same set of plans if he built the house on the adjoining lot. I told him a complete new permit with full permit fees would be required in that case because the plans would have to be routed through all city agencies again. He said he understood. GP E GRIF Building Official •. - .111 John Michael Easter -�•� 244 -2978 ADDRESS 4820 South 150th, Seattle, WA MP 98188 :ONTRACTOR Singleton Building Corp. PHONE 322 -9200 ADDRESS 3130 East Madison, Seattle, WA ZlP 98112 NA. ST. CONTRACTOR'S LICENSE # SINGLBC124KD EXP DATE 3 - 24 - 92 ARCHITECT PHONE ADDRESS ZIP • . : V - I e • year 1988 SETBACKS: N - S - E- W - FIRE PROTECTION: ®Sprinklers 0 Detectors 0 N/A UTILITY PERMITS REQUIRED? Ll Yes 0 No (th Pu Worka1 ZONING: BAR/LAND USE CONDITIONS? 0 Yes ©No :ONDITIONS other than those noted on or attached to permit/plans) kPP RED FO BUILDING SSUANCE BY: OFFICIAL DATE: 1 hereby certify that 1 have read and examined this permit and know the same to be true and correct. M provisions of lav and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. 3IGNATURE: ""I /� •• ' e - DATE: 5-'- `7 — et 1 COMPANY: p w e e I-- . i°' PRINT NAME: el, - r : 144"4 6166‘... :ITV OF TUICWILA )ept. of Community Development- Building Division '300 Southcenter Boulevard, Tukwila WA 98188 206) 431 -3670 WILDING 9 ERMIT NO. )ATE ISSUED: ISE LOOR TOTAL CERTIFICATE OF OCCUPANCY NO. BUILDI. (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) DESCRIPTION BUILDING PERMIT PLAN.CHECK FEE ><< .: BUILDING SURCHARGE:::::.:. TOTAL -> FEE S 590.00 <''384Of1 978.50':: RCPT# : DA 1eL 4 D.WYISMi. 0-,26 »'90 it= MIME PLAN CHECK NO.: 90 -444 SUITE# VALU 0 CO STR CTION - $88,950.00 iITE AD 'R S 4816 S 150 'ROJECTNAMElTENANT Easter, John & Christi ASSESSOR ACCOUNT # 004200- 0150 -08 TYPE OF 1© New Building [J Addition U Tenant Improvement (commercial) U Demolition (building) U Grading/Fill WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) 0 Other: )ESCRIBE WORK TO BE DONE: Construct single - family residence. :CQDE COMPLI'AN.CE SQUARE OCC. LOAD OCC. SQUARE �:• .. OCC. LOAD , SQUARE FEET SQUARE FEET OCC. TOTAL 3.OAD SQUARg FEET OCC. LOAD SQUARE FEET TOTAL 000. LOAD This permit shall become null and void it: the ..work is:not commenced. within 180 days from the date of issuance, or if the work is suspended or abandoned fora period of days from the last inspectlon.' DATE ISSUED: PERMIT NO. CONTACTED Ch -t DATE READY DATE NOTIFIED 5 ,-) f CO BY: 8 PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING ° t' ` . d 3RD NOTIFICATION BY: snit. PLAN CHECK NUMBER I A SITE ADDRESS BUILDIN(PERMIT APPLICATION TRACKING INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. �► Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) DEPARTMENTAL REVIEW "X" In box Indicates which departments need to review the project.. FIRE BUILDING - initial review (PLANNING ck PUBLIC WORKS 0 OTHER BUILDING - final review Jo qo REVIEW COMPLETED INIT: INIT: !NIT: CSL % ' Cc' 10 ROUTED 261 51: FIRE PROTECTION: ZONING: INIT: LA. %-. 3E IR . Date Sent - FIRE DEPT. LETTER DATE REFERENCE FILE NOS.: 5-1 t 'I'YP OF CONSTRU5T N'. 30 UT LITY EP RMITS REQUIRED? (rY [� PUBLIC WORKS LETTER DATED: Date Approved - Detectors ■ N/A INSPECTOR: 1 USE CONDITIONS? Yes No MINIMUM SETBACKS: N- Sy E es No U EDITION (year): SITE ADDRESS SUITE # k[ (% ,�} /J'l / . c rr77/7r I,cv,!., VALUE OF CONSTRUCTION - $ q CI S° 6) IS °•D° ASSESSOR ACCOUNT # Coo Lf o 0-- or 50- O PROJECT NAME/TENANT Ca.,fi.er , 1i oh �'� / �_ TYPE OF ( New Building U Addition U Tenant Improvement (commercial) U Demolition (building) WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) 0 Other DESCRIBE , t WORK TO BE DONE: C l `/ S / //r / Ciir)f / i r stc n 6-/ c' ('C -i?`i/ Yc( C. of 7C/ BUILDING USE (office, warehouse, etc.) c/ NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? No 0 Yes IF YES, EXPLAIN: SQUARE FOOTAGE - Building: / e 4f. & Tenant Space: Area of Construction: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? {3 No O Yes IF YES, EXPLAIN: PROPERTY OWNER T , J / 1r7 / ,l /-l-),, 77/ PHONE 1 1--`1- 1 y 7AI. ADDRESS �, „2. C ;! / ` t- c .. , . 7 ! , -�. , S.- te -7`/ l - / ZIP 7 . 1 (V c`�' F7 CONTRACTOR ,",. 5,;, /�c; t /cuf PHONE 3.L.Z- ` /,.Z.oC'J ZIP r- l c c3' // � ADDRESS !� / ' / 7 G' .0 / c ,chS C.∎ <2 .S cz 177 4 6' WA. ST. CONTRACTOR'S LICENSE # > 07c / 4 3 C / . �,_ 4 / EXP. DATE `� _ c, / ARCHITECT - PHONE ADDRESS ZIP CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 APPLICATION MUST BE FILLED Out COMPLETELY , BUILDII3 PERMIT APPLICATION UILDING .PERMIT FEE PLAN;.CHECK: UILDING :SURCHARGE ::: DESCRIPT o AMOUNti ;. CPT:.t1!: ERTIFY;" ................... BUILDING OWNER SIGNATURE OR AUTHORIZED AGENT CONTACT PERSON PRINT NAM 1 ' ADDRESS '. -cf7 4 DATE /0 3 c! 0 PHONE ,( PHONE (&C, APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed Information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is Issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. N you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES CITY /ZIP .7/0610 COMMERCIAL NEW COMMERCIAL BUILDINGS/ADDITIONS Ej Completed building permit application (one for Assessor Account Number. Two sets (2) of the followings Specifications Structural calculations stamped by engineer Soils report stamped by it Washington Stabs Wanted Topographical survey >: Energy calculations stamped by a Washington State licensed . engineer or architect El Legal description Working drawings, stamped by Washington State licit architect, which Include:,: " Site plan 9 Architectural drawings ▪ Structural drawings • Mechanical drawings • Elevations • Civil drawings Landscape l? Campieted utility permit application (one for arid! • Six (6) sets of civil drawings Washklat ► Sltee Ilpen NOTE:: See utility permit application and checklist for apedtl submittal requirements. • RACK STORAGE • Completed building permit application'::` Assessor Account Number Two (2) sets of plans, whlch include: n Building floor: pion showing , ': • Entire space 'whatq racks will be foes • Exit doors • • DI menstons of all Tenant space boor plan *hewing re*: e>dts • NOTE lr.cluda:dimensrons of tacks (tretphf, width and kwlq t}, and exit ways on calculations stamped by a Washmgtan Stute:lice engineer (rack storage 8' and RESIDENTIAL S6BMITTAL CHECKLIST • NEW: DWE41,WNG8/ADDITf Completed building p.nmitapplicatioh, (one torr!Itch Legal desadptfon Assessor Account Number Twa seta of working drawings, which to • Site. plan ■ • (Can ptar►, sl ..... w.rPryaitiprt, • Foundation plan ktdluda aaoe*e b**? atiavint . • Floor pl rt1trd bra a f. Ere ts Roof plan . Building elevations (all view; Nor Building cross - section; • Structural training plans Washington State Energy Code data ( mil Completed utility permit 'application ..: Six (6) sets of site piaris showing unties NOTE_: BuAdnp site plan and utility site plan may bo contbkrad ; uWly paarmlt application and cbecWiat fps s p®c IBO itubmdttal requlremonte Adc#f onat topographical and soils inkrrmaoron may be regc krrd d►unk a slut conditions.: < .: ... .................................. ....................... COMMERCIAL TENANT IMPROVEMENTS r conatruCtion details • Crate seotiiuta show ng wai oo and method o f • Poi fbur and celhg 3fruoturawl stauysod by.a Washington Stets dcensed erpineer m ay b rag ts xa d ; 11 strtsulural work is to be done (2 sets} • • NOTE; M any trd7fty wvrk k to be cone, aubmlt sail u.�type appAcatYon and pfanA `: ;: REROOF Completed bupdine permit app llcadixt (ores; for o AaseasocAocount' Number :Narrative describing existing roof, matadal being removed • 'tnaterial being insmlled • NOTE A certification latter la rbquked prior to flnat inspection and s off al the permit Completed bulcfing permit application (ogre for each ettucture or tenant} ANTENNA/SATE.LLITE : RP S HES • Completed buildinC peemlt appUR Aase:tsor Account Numbe tY07� if any uBky oilt is to be • don aced plansmtrst be $t*mrtmd : REROOF$ Cormpk teed bu lking p ermit apptrca ion asessor Num roof, notarial one for eactt:stiuotu UTILITY PROJECT TRACKING CHEC ST Control# 90 -444 SITE ADDRESS_ 4$10 3 15b Project Description New Residence PROPERTY OWNER John Easter Address 4820 South 150th, Tukwila, WA CONTRACTOR Singleton Building Corp. Address 3130 East Madison, Seattle, WA CONTACT PERSON John or Christi Easter Address 4820 South 150th, Tuwkila, WA ROUTING DATE PLANS RECEIVED TYPE OF REVIEW 10 -26 -90 Site Utility PERMITS REQUIRED APPROVED PERMITS PERMIT # PLAN /LETTER DATE ISSUED DATE FINAL (l Channelization /Striping/ Signing J Curb Cut /Access /Sidewalk [I Excavation (public) O Fire Loop /Hydrant O Flood Zone Control O Hauling [( Landscape Irrigation (] Moving an Oversized Load O Sanitary Side Sewer O Sewer Main Ext. (private) [ J Sewer Main Ext. (public) ❑ Storm Drainage [� Water Main Ext. (private) O Water Main Ext. (public) O Water Meter (exempt) Size: No. O Water Meter (permanent) Size: No. Q-Water Meter (temporary) Size: No. 10 -26 -90 Q Other O Other CONDITIONS OF PERMIT ISSUANCE OR FINAL SIGN -OFF OF PROJECT FINAL PWD SIGN -OFF APPROVAL (signature) (PW.UTILTRK) PROJECT Easter, John Square Footage 1,848 Phone 244 -2978 Zip 98188 Phone 322 -9200 Zip 98112 Phone 244 - 2978 Zip 98188 DATE ROUTED DATE PLANS DATE RESUB. TO PWD APPROVED REQUESTED COMMENTS Date CONDITIONS Yes / No ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 0 . ❑ ❑ ❑ ❑ xv 1 HEREBY CERTIFY THAT 1 HAM READ TH1S APPLICAnON AND KNOW THE SAME TO BE TRUE AND CORRECT. Applicant/Authorize Agent Signaturg: /•(; IYK .A:t..---( ..1.- /Al/ CA a -ci 1:‘ /9s ri , - " X Contact Person (print name): chv s i i - i 4 Address: 4 e - 8,20 S. /5 S. ?.E3/&& Print Nam&: k) Date: ) - -- - 0 Phone: :2, 9-9- c(* se Phone: P.. 9- 4 1 , -- a. 9 ,8 Date Application Accepted: h_...Q _ 0 Date NvcatiorjL ....e....... a ............... Lxpires CITY OF TUKW1LA Central Permit System - Engineering Division 6300 Southcenter Blvd., Tukwila, WA 98188 Phone: (206) 433-0179 UTILITY PERMr. APPLICATION PLAN CHECK NUMBER: 111INIMINV . 4•1•1111111•1 • • PROJECT, INFORMATION Pro ert Owner: Site Address: LisL(E) 5 7` Name of Project: - E3t -- -e.r` oh r (;c. tct-e. - ir Street Engineer: Street Address: oS - Contractor: Si p7 Street Address: / 2 0 L7 WATER METER Name: DEPOSIT/ REFUND/BILLING Street MONTHLY Name: SERVICE:: BILLINGS Street 8 O Office O Retail / F.- S TIC:X So 1.71 /SC Pi a S O Warehouse O Manufacturin c, 0,, King County Assessor Account Number: 00 - 0 „s - PERMITS 0 Channelization/StripIng/Signing REQUESTED 0 Curb Cut/Access/Sidewalk 0 Fire Loop/Hydr. (main to vault) - No.: Sizes: O Flood Zone Control O Grade/Fill cubic yards O Hauling O Landscape Irrigation O Moving an Oversized Load IX Sanitary Side Sewer - No,: 2. O Sewer Main Extension Private 0 Public 0 1 Water 1R1 Sewer 0 Metro 0 Standby IR SI le-Farrridentlal DESCRIPTION OF PROJECT O Multiple-Family Dwelling 0 Hotel 0 Duplex 0 Apartments No. of Units: 0 Motel 0 Tri lex 0 Condominiums • CommerclaVindustrial O Church O Hos ital Phone No.: Cit /State/ZI Phone No.: Cit /State/Z Phone No.: 3,2a czo c, Cit /State/ZI • o• (),..,3 c1 feir) S City/State/Zip: Phone No.: City/State/Zip: O Other: 6 )• O Storm Drain O Street Use O Water Main Extension PrivateD Pubic R-Water-Meter4-Exempt---No7:-2--Sizes: Deduct 0 Water Only 0 a Water Meter / Permanent No.: 2._ Sizes' O Water Meter / Temporary: - No.: Sizes: O Other: IC) AC1 uc //nr 1101111•IEUAR Phone No.: ct 297 0 School/College/University O Other: [g MISCELLANEOUS Z New Building 0 Remodel/ Square footage of original building space: INFORMATION Square Footage: ig8 `t- Addition Square footage of additional building space: King County Assessor's valuation of existing structures: $ Valuation of work to be done: $ 09/18/90 SUBMITTAL CH , KLIST All site plans shall be provided in one submittal for review by the Public Works Department. Six (6) sets of plans stamped by a licensed engineer are required along with this application completed and signed by the applicant's representative. The following information is necessary for Public Works Department evaluation and approval of site plans: • All utility construction is to meet the City of Tukwila Standards • Indicate scale of drawing and show north arrow • Identify location by address or distance to nearest Intersection CURB CUT /ACCESS /SIDEWALKS/ CHANNELIZATION /STRIPINGISIGNING O Dimensions O Type of surfacing - asphalt, crushed rock, etc.(and thickness) O Percent of slope or runoff direction O Size of curb cutsllocation O Vehicular and pedestrian traffic facilities, including signing and striping, wheel chair ramps, curb cuts FIRE LOOP /HYDRANT O Type of pipe O Size of pipe /location O Location and type of all valves O Type of bedding and backfill materials /percent compaction O Distance from structures, storm and sewer facilities at minimum separation O Location and size of thrust blocking FLOOD ZONE CONTROL (Requirements are under Flood Ord. No. 1462 and can be obtained from the Public Works Dept.) O Lowest finished floor elevation O Contours and elevations per National Geodetic Vertical Datum LAND ALTERING (CLEARING, GRADE AND FILL) O Contour map (2' intervals) showing existing and proposed contours O Estimate of yardage, both cut and fill O Erosion control plan HAULING O Copy of Certificate of insurance coverage (minimum $1,000,000) O $2,000 bond made out to the City of Tukwila for property damages caused by activities O Route map LANDSCAPE IRRIGATION O Location of DSHS approved double check valve O Type of pipe - copper, high density molecular plastic, ductile O Size and depth of pipe O Size of meter O Location and elevation of meter box (water meter - permanent and exempt). Clearly show whether tap is on main or domestic service O Location and type of tap O Type of bedding and backfill materials/percent compaction MOVING AN OVERSIZED LOAF) O Copy of Certificate of insurance coverage (minimum $1,000,000) O $5,000 bond made out to the City of Tukwila for property damages caused by activities O Business License with City of Tukwila O Route map SANITARY S I SEWER O Type of pipe - rete, PVC, etc. O Size of pipe/location O Percent of slope on pipe/length of run O Connection points) to public O Location of cleanout(s) and test Tec(s) O Type of bedding and backfill material/percent compaction O Invert elevations at structures and junctions SEWER MAIN EXTENSION O Type of pipe - concrete, PVC, etc. O Size of pipe /location O Percent of slope on pipe/length of run O Connection points) to public O Location of cleanouts O Type of bedding and backlit! materiaUpercent compaction STORM DRAINAGE (including existing topography and proposed grading and surfacing) O Type of pipe O Size of pipe O Percent of slopellength of run O Location of all structures O Square footage of area to be drained, including roof area O Bedding material for pipe O Invert or flow line elevations STREET USE O Complete description of proposed activity O Map with address and outline of limits of activity relative to public right -of -way and easements O Proposed traffic control/detour (per Manual of Uniform Traffic Control Devices) O Proposed schedule (times and dates) WATER MAIN EXTENSION O Type of pipe O Size of pipe O Hydrant type and locations O Valve type and locations O Connection points) to existing system O Type of connection - live tap, tee, etc. O Location and size of thrust blocking O Size and location of mains, including elevations (profile) WATER METER - EXEMPT O Diagram of domestic system/tie In of exempt meter O Number /account for existing domestic meter O Size and type of material of meter and service O Site address WATER METER - PERMANENT O Type of pipe - copper, high density molecular plastic, ductile O Size and depth of pipe O Size of meter O Location and elevation of meter box (water meter - permanent and exempt) O Location and type of tap O Type of bedding and backlit! materials/percent compaction WATER METER - TEMPORARY O Address and hydrant location O Size of meter O Estimate of quantity and schedule After the Public Works Department has completes - their rev ew an t e p ans are apprWeriffeTpplicant will be notified by letter concerning the necessary permits and requirements; an approved set of plans will &ccompany the letter. ff the plans ar not app roved, the applicant will be notl/led b let ter of necessary resubmmai requirements. "1:)WQI l( 29 G arb TO: FROM: DATE: SUBJECT: oAue d i_Dn t - ton I',5 [tea.) an (5I (10 /T2.MEMO) Cit of Tukwila 6200 Southcenter Boulevard Tukwila Washington 98188 (206) 433.1800 Gary L. VanOusen, Mayor . Fi ��X11i 15Ckt.2 . C Ci©lpc.r 1 Q1 O �e C c� P a1ooi 0 -cL. MEMORANDUM 5 o • <64, 51S. Qo - iota\ s<6 , f So J-10 r lb Values 9o. co Plan Ch K fur Chore "5S L{ o0 4.6o, l 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 I 23 24 25 26 27 28 29 30 31 k 32 33 34 35 36 37 39 40 41 42 43 38 I 5 44 !� d cv Creative Engineering Options INC. PROJECT NO. SHEET PROJECT &-Mer / 482.o S, iSo}� .+reet COMPUTED BY Gm SUBJECT zeicol P.. /e404.< ,,+ Se .+ CHECKED BY • Geotechnical Engineers, Geologists L Environmental Scientists ' iri IVNFr) PP7' 2,997 TYPICAL PAVEMENT SECTION • '' q o • •'� Q: `.. o `.�.ti LD " �.Os •sto.+ Cse rCl.♦ ' d r p , t O .. Native subgrade soils to be redensified and subgrade fill soils to be compacted to 95 percent of Standard Proctor dry density. 91 -1138 OF DATED 111-1 DATED t — 2- inches Class "B" — 4- inches Crushed Rock All native and fill subgrade soils should be treated in general accordance with the . recommendations contained in the geotechnical report provided by Creative Engineering Options, Inc., dated March 7, 1991. If fill is to be placed over a sloping roadway subgrade, the subgrade surface should be cut flat and horizontal to provide a level surface on which fill canbe placed and compacted, and to avoid the creation of a potential plane of failure between the fill and underlying native soil. 414333 1Y/0,1 NI • 11441uti »u3, WA 9II0 • 1.4)(4 sot (,1UN) • j,IY■I'P.11111 1 A\ (?3I 3'.9! LEGEND T t# 599E tiEr 90S Subsurface Seepage -m•--1111 Creative Engineering Options ,NC, M40 csoaeoOkS Crcheers. Ccotges0 a Emenwryncel iderinn 4-Z6SE ti9990z Schematic Onty • Not to Scale H1 f3a noh min, 1-1/41n. 90 100 3/4 In. , 0 20 3/e in. 0 2 Roadway Surface Varies 12-inoh min, penetration Into impermeable soil Gravel 8acktlll for drains: WDOT Standard Spedficattons, shall consist of material meeting gradation of Mx No. 4, Section 9- 03.1(3)C, % Passim Steve Size Min, Max, 1.1/21n. 100 - TYPICAL INFILTRATION TRENCH DETAIL 4820 South 150th Street Plsta 3 Nd00 : TO T6 -Zv -a0 00Z4S0 I Hdh?1nhiHdld : As bras Associates. undated. i LOT A 4820 SOUTH 150th STREET EXISTING HOUSE APPROXIMATE INFILTRATION TRENCH LOCATION 240 -Feet TP-1 A TP -2 Scale is approximately I- inch32 -feet A 4- LOT B TP -6 -6 - 8 _ -10 -12 14 16 -18 -20 -22 -24 -26 TP -3 19 -28 -30 TP -5 Creative Engineering Optlonsavc N.,lcv Geotechrsical Enolnecri. eeoioahts t EnAtonna,ral Sde,llst& LEGEND PROPOSED USE TP -6 Ei Approximate Location of Test Pit TEST PIT LOCATION PLAN 4820 South 150th Street RECEIVED APR 16 1991 TUKWiLA PUBLIC WORKS Plat( 2 SEE 35MM FILM CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUK {VILA, WASHINGTON 98188 April 30, 1991 Ms. Christi Easter 4820 S. 150th St. Tukwila, WA 98188 RE: Site Address: 4820+ S. 150th St. - Easter Single Family Residence Utility Permit Approval PC# 90 -444 Dear Ms. Easter: The Public Works Department has reviewed and approves the site plan for the above mentioned project. This approval is for Public Works review only. You are referred to the Tukwila Fire Department and the Department of Community Development for their approvals. All utilities servin• this site includin• sower and •hone must be installed under • round er TMC 13.08 PHONE a (206) 433.1800 Cary L Vn Alayor Please call Denise Millard, Permit Coordinator, at 431 -3672, to have the following permits prepared for pickup: 1. Curb Cut /Sidewalk /Access (Permit Fee $25.00) This permit is for construction of a 20' private drive, with connection to S. 150th street. The construction shall comply with the design and recommendations of the geotechnical engineer and City of Tukwila Standards. The maintenance of this driveway is the sole responsibility of the underlying property owner(s). 2. Storm Drain (Permit Fee $25.00) This permit is for construction of the drainage system for this property, including the proposed percolation system. All construction shall comply with the design provided by the geotechnical engineer, and City of Tukwila standards. April 30, 1991 Ms. Easter Page 2 The Storm and Surface Water Utility charges must be adjusted to reflect the change in use of this property; please complete the attached Informal Adjustment Request Record, requesting a rate change to single family (category 07). 3. Grade & Fill (Permit Fee $76.50) This permit is for the earthwork portion of the project. Construction must comply with the recommendations and design of the geotechnical engineer, and City of Tukwila standards. This permit is issued under Chapter 70 of the Uniform Building Code. Your application was accepted on 10/26/90, prior to the adoption of the current Land Altering Ordinance. This development is therefore vested under the older law. 4. Street Use (Permit Fee $25.00) This permit is for work in the public right -of -way (the proposed widening of S. 150th street). This work is to be done under the direction of your engineer and the City Inspector. All construction must comply with City of Tukwila standards. Where required, warning signs, barricades, and flagmen must comply with the Manual on Uniform Traffic Control Devices. Greg Villanueva, City Inspector, can provide you with a work zone control booklet to assist with this matter. You are required to maintain existing accesses at all times (typically one lane open). Prior to issuance of your permits, please revise your application to request all of the above permits, as they are all required for this development. You are referred to Val Vue Sewer District for your side sewer permit, and to Water District #125 for approval of your water service. Prior to beginning construction, please call Greg Villanueva, City Utilities Inspector, to arrange for a preconstruction conference. Greg can be reached at 433 -0179. Prior to occupancy, your soils engineer of record must submit written confirmation that he or his representative has inspected all earthwork, drainage, and roadway construction; and that all such construction is in compliance with his design and recommendations. April 30, 1991 tMs. Easter Page 3 Please complete the attached copy of the Residential Sewer Use Certification, and forward copies to Metro and Val Vue Sewer District. If you have any questions, please feel free to call me at 431 -3673. U Ross S. Heller Senior ngineer Enclosure(s): Plan, IARR, METRO'form RSH /arc:RSH10:Easter3 xc: Greg Villanueva, Inspector - w /site plan Denise Millard, Permit Coordinator METRO, Val Vue, PW Read File, Dev.File:Single Family 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 • If fill is to be placed over a sloping roadway subgrade, the subgrade surface 29 should be cut flat and horizontal to provide a level surface on which fill canbe 30 placed and compacted, and to avoid the creation of a potential plane of failure 31 between the fill and underlying native soil. 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Creative Engineering Options INC, (16., = Geotechnual Engineers. Geologists d Environmental SclentiSt$ PROJECT EusFer /482o 5.15 s4-reet SUBJECT INQ1G41 P.,ver•+t• Sec.-Ho" TYPICAL PAVEMENT SECTION O'er. G. •,: •,dAA x .0.1. 0 '.' ' Gs.s - ♦q „v�r�•r ;Jo PROJECT NO. 91-1138 SHEET 1 OF COMPUTED BY Crm DATED CHECKED BY DATED Native subgrade soils to be redensified and subgrade fill soils to be compacted to 95 percent of Standard Proctor dry density. d r I 2ZIgl — 2- inches Class "B” 4- inches Crushed Rock All native and fill subgrade soils should be treated in general accordance with the recommendations contained in the geotechnical report provided by Creative Engineering Options, Inc., dated March 7, 1991. ..4 lit I 'Oil 1 PI.I e l41 ' lietlin11nrl, WA 9 11051 • (: I N.I NH I f.IUi'1 • I /('. 'P, l 1111 I AX IU 1'M1 LEGEND ent ' Creative Engineering Options INC. CEO Geateanrite Engheas, Gaoiog00 4 EnvMorrxrui Wentrts Schematic Only • Not to Scale Subsurface Varies Seepage F 6 an 0 h min, % Passing Sieve a Size Min. Max. 1- 1/21n. 100 - 1.1/41n. 90 100 3/4 in, 0 20 3/8 In. 0 2 Roadway Surface T t4 S99E TEta 90E 4- e65£TSS9Z1 Wd00 t TO .T6 12 -inch min. penetration into impermeable soil 1 Gravel BackfIll for drains: WDOT Standard Specifications, shall consist of material meeting gradation of Mx No. 4, Section 9.03.1(3)0, TYPICAL INFILTRATION TRENCH DETAIL. 4820 South 150th Street Plate 3 1 t' r#Sz) I HdHbD0Hd1H : AH 1N3S eton Associates. undated. rid TP -1 LOT A 4820 SOUTH 1S0th STREET EXISTING HOUSE i• APPROXIMATE INFILTRATION TRENCH LOCATION 240 Feet Scale is approximately 1- inch32 -feet Ly TP2 LOT B TP -6 -10 TP5 Creative Engineering Optlonsr+c. rIcro 1 G V Geotechrice Engineers. Gcotoghcs a En4ramiertal Sda,nsa s•011& z PROPOSED _HOUSE LEGEND RECEIVED APR 16 1991 TUKwit.A PUBLIC WORKS TP -6 61 Approximate Location of Test Pit TEST PIT LOCATION PLAN 4820 South 150th Street PIatE 2 SEE 35MM FILM Dated Agreement To Be Subject"' To A Sensitive Areas Ordinance The undersigned owner and developer of real property located at 4820 south 150th PI and more specifically described in Exhibit A attached hereto, hereby agrees, pursuant to the requirements of Tukwila Ordinance No.'s 1544.and 1550, that if the City of Tukwila will process the following . applications: ‘ 5 7 / c rj' /" /� /; -- ! ! i 1 , J a 1.7C+4. e ?v - c, P fr the development of the property described in Exhibit A will be subject to all of the Sensitive Areas Ordinance provisions as finally passed by the City Council even though those provisions may be more restrictive than any conditions or limitations imposed by or resulting from the processes described above. The Undersigned agree(s) that these processes will be continued solely at their risk and expense and that the result of the final Sensitive Area Ordinance may be to require extensive project modification and re- evaluation or recision of the above approvals. It is also understood and agreed that continuation of these processes does not mean that applications not pending on November 20, 1989, for this project, will be accepted or processed unless the. City Council approves a petition therefor. The undersigned acknowledges that the covenants herein run with the land described in Exhibit A and that this document will be recorded with the Ring County Department of Records and Elections and that these covenants cannot be released without the written consent of the City of Tukwila. STATE OF WASHINGTON ) ss. COUNTY OF KING ) On this day personally appeared before me - 56\n/ ., .E.✓ , to me''known to be the individual described in and who executed this and acknowledged that s /he signed the same as a free and voluntary act for the uses and purposes herein mentioned. - 1 1 '7 � I 1 Applicant Notaryi Public in and for the State of Washington, residing at �wr /A k'A I& My appointment expires .4447,s-1 :..; RECEIVED CITY OF TUKWILA OCT 2 6 1990 PERMIT CENTER 1)44e ... •. �F.. . h., d.,i`..certif.icate.,.prov,ides the epartment" � and Bu ding; &. Development . ith'`•.informa.tionnecessary to e.valuate•development proposals. i ':Building ,y ;i j "Short' Su APPLICANT'S NAME V d // c,ROPOSED:,.USE_ Gc.I P LOCAT i9N • 4 . /50a� (Atta h. map & legal d # ; # # ATER. PURVEYOR. INFORMATION ' Water will be provided by service connection only to •water „main , :5" • feet from the site.`' Rate of Flow eye. `k, hereby:' certify :.t'hat the ;certification; shall.be..val less than 500 gpm (approx. to 999 : gpm ' • 1000,;'gpm or m're flow of ❑ calculation of gpm gpm W ZaT '7 / 41, /,5 > ,<5 Please return to: BUILDING& LAND_DEVELOPMENT 450 Administration Building Seattle, Washington 98104 206.344.7900 '. KING COUNTY CERTIFICATE OF WATER AVAILABILITY Permit ❑ PreliminaryP1at ' orPUD c bdivision ❑ Rezone or other • 3 1 0 - ' 4 cription if necessary). A11 ,0 i ■�ff P,. Zlie 2 an,existing Water will require an improvement to the water system of: • (1) ' feet of water main to reachthe'sitet and /or (2).', the construction of a distribution system on „ the . site;. and /or (3),: other (describe) •The.,.water'.system is in conformance with a County approved water;comprehensive plan. t -` ,The;,water,system improvement will require a water ; comprehensive,plan amendment. The proposed project is within the corporate limits of the district, or has been granted Boundary Review Board approval for extension of.'service outside the distric ori:,city, or is within the County approved service. area of a pri,vate.water purveyor. Annexation or BRB approval will be necessary to provide service. Water is /or will be available at the rate of flow and duration indicated below at no less than 20 psi measured at the nearest fire hydrant_ O O feet from the building /property (or as marked on the attached map): Duration ❑ less than'1 hour our to:2. hours. FOR hours or • more I'.. Ali: ❑ other (Commercial Building Permits require flow test or calculation) providing M above water purveyor . information ' is` true,.;?;::This id for one year from date. of ,- gnature.`' �( d °a `xhis cbrtificate provides the Department of Health and Building & Land Development with information necessary to evaluate development proposals. KING COUNTY CERTIFICATE OF SEWER AVAILABILITY ono wraain as •ox APPLICANT'S NAME �Q}/L M/ A, t L , a 9 7(1'' PROPOSED U SIN , Ix e � � LOCATION •S, C) -SD . S 1. a. F279 number ❑ Building Permit ❑ Short Subdivision ii _ Y 2. p � (Attach map & legal description if necessary) # # # # # # # # # # # # # # # # SEWER AGENCY INFORMATION Sewer service an existing and the sewer OR b. Sewer service 2. (Must be completed if 1.b above is checked) • The sewer system improvement is in conformance with a County approved sewer comprehensive plan. OR b. The sewer system improvement will require a sewer comprehensive plan amendment. 3. a. The proposed project is within the corporate limits of the district or has been granted Boundary Review Board approval for extension of service outside the district or city. OR b. ❑ Annexation or BRB approval will be necessary to provide service. 4. Service is subject to the following: a. Connection charge: .. 1)L.ce n_ten� l Cao►,7y6Ci'to� b. Easement(s): m,Q y gyp= r2,L,g c. Other :_.'k, /,r/, t wl;t..tr Ralis-t<<t.e A. INAmp Sys risrrl St "lb Se heAsoDo•-) i % 3 6ptaurty seav ec . Ls AvatLATzt -=. I hereby certify that the above sewer agency information is true. This certification shall be valid for one year from date of signature. yAL VUE SEWER D1S'1`llL;1' Agency Name MANAGER Title 0 (1) and /or ❑ ( 3 ) other (describe) 450 Administration Budding Seattle, Washington 98104 206.344.7900 • name 03 Plat or PUD ❑ Rezone or other *rig? Please return to: BUILDING & LAND DEVELOPMENT 'JG will be provided by side sewer connection only to (r size sewer / feet from the site system has the capacity to serve the proposed use. will require an improvement to the sewer system of: feet of sewer trunk or latteral to reach the sites ❑ (2) the construction of a collection system on the sites and /ter M AT E L1 C1 -1 Signatory Name SEE 35MM FILM CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUKWILA, WASHINGTON 98188 December 2, 1991 Mr. John Easter 4820 South 150th Seattle, WA 98188 Dear Mr. Easter, PHONE # (206) 433.1800 Gary L. VanDarn, Mayor RE: Your letter, dated 11/24/91, Request for Extension of Tukwila Building Permit No. 6580 1. I regret to inform you that your request for extension of the above referenced building permit cannot be extended because of the following reasons: a. The permit expired prior to your requesting an extension. Section 303(d), Uniform Building Code, states that building permits expire by limitation and become null and void if the work authorized by such permit is not commenced within 180 days from date of such permit. b. This section further states that "any permittee holding an unexpired permit may apply for an extension of the time within which he may commence work under that permit when he is unable to commence work within the time required by this section for good and satisfactory reasons." In this case, however, your permit had expired before you requested an extension. Also, the building code only allows for one extension not to exceed 180 days, and your request is for six to twelve months. c. The code further states that "to renew action on a permit after expiration, the permittee shall pay a new full permit fee." 2. Another reason for not granting your request for extension is that the State has mandated the enforcement of more stringent and additional building and construction codes since your permit was originally issued. Specifically these are the Washington State Energy Code and the Washington State Ventilation and Indoor Air Quality Code, both which became effective July 1, 1991. Since the plans submitted for your permit did not include the requirements of these new codes I do not feel it would be appropriate to extend your permit past the original expiration date. 3. Based on the above, permit #6580 is expired and considered null and void. If you should have any further questions please feel free to contact me at 431-3670. Sincerely, u• e Building Official cc: Permit Coordinator iD6Re MR. 6eirri 0.; Due T� 5cdivornio coivoinbAks 47ELy 016 c5rrnv erg__ l OOK i5u/c4/Ag, Pgeril_r_7" 65,5'"0 (refi&I y0 ://e W Worn _ foi Sly 1 77,064.9e Monirtis, Does 77/43 • C/7 OF 7uiaxi■09 111.2 01 ealtibiwuiTY Deu6top. 6o1lfuo 41■Iksis le 7 I4J4sw/tuGroA) 9?/ : DoWlgyni 6g114 , tAlt Do 13g4 ti(16 cex.kx oer4/10 r/NRAlakio , TiMAJ/ Voo roe YouK cong'f1 so. • /6 - edi (5(5977 9sygcp 070/- 0 ,19'76> Pc69s6 cfte, col ouGvioNs NOV 211991 -CITY--F-ITu ILA_ PLANNING DEPT. s CITY OF TUKWILA 6200 SU VTHCKNTER BOULEVARD. TUKWILA, N'ASIIINGTOV 914188 Plan Check #90 -444: Easter, John & Christi 4816 S 150 St HUM a (206 433.1800 THE FOLLOWING COMMENTS APPLY TO AND BECOME PART OF THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER (o5 . 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296 - 4722). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (277 -- 7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. 5. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. Engineereed truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 7. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 8. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 9. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. Gary I.. Iunlnsen, Mayor 4 Easter, John & Christi Page 2 10. All wood to remain in placed concrete shall be treated wood. 11. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation' of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. "X" REQUIRED INSPECTIONS PHONE APPROVED INITIALS CORRECTION NOTICE ISSUED 1 Footings 431 -3670 X 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431-3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 7 Framing 431 -3670 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 x 10 Wail Board Fastening 431 -3670 11 12 . 13 x 14 FIRE FINAL insp: 575 -4407 15 PLANNING FINAL 431 -3670 x 16 PUBLIC WORKS FINAL 431 -3670 X 17 BUILDING FINAL 431 -3670 i • (INSPECTOR COMMENT SECTION ON REVERSE) CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: 4816 S 150 1:5uiLur:► u rcnivoe I INSPECT:•N RECORD SUITE NO.: (Post with Building Permit In conspicuous piece) BUILDING (D5%.o PERMIT NO. DATE ISSUED: PROJECT: Easter, John & Christi CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if understab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is In place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. , FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (Including gas piping) — King County Health Department — 296.4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although rrot required, a meeting of this type can ofte' eliminate problems, delays and misunderstandings as the project progresses. V 1. Footings 2. Foundation 3. Slab /Slab Insulation 4. Shear Wall Nailing y 5. Roof Sheathing Nailing 6. Masonry Chimney 7. Framing 8. Insulation 9. Suspended Ceiling x 10. Wall Board Fastening 11. 12. 13. X 14. Fire Final 15. Planning Final X. 16. Public Works Final Z 17. Building Final Plan Check No.: 90 ` 44 4- Project: C.AS TER, �c)H t∎S PAN REVIEW COMMEFITS No changes will be made to the plans unless approved by the Architect REQUIRED INSPECTIONS , and the Tukwila Building Division. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277 - 7272). X All mechanical work shall be under separate permit through the City of Tukwila. X All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building Inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special Inspected (Sec. 306, UBC). 8. Alt structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high - strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and Tight fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 11. Partition walls attached to ceiling grid must be laterally braced 11 over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. . Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 4. Any exposed insulations backing material to have Flame Spread Rating of ( 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of root will be required prior to final inspection (see attached procedure). Ali construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. t 4. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. t Ai iiCONVERSATION RECORD DATE: M N n1E wE� --MI' FRRI SAT SUN TIME: / P.M. TYPE: ❑ Visit E] Conference El Telephone— Q Incoming 0Outgoing Name of person(sJontacted or in contact with you: Q GS Organization (office, dept., bureau, etc.) Location of Visit/Conference: n, SUBJECT: SUMMARY: ed-cr 5 ✓ Can y`u c. - 54a/712 - Cr'/1 0 vin a M 1 Ccce 15 /1 -1 . liok 071 plan .. " 5�j1 /)rYn 5 t �j► t e 4 terns ��"u � wl gg /s f . access re /Mainn�nce- prrer5 nw,ner . 7 5- a r4 21c 5er VI Ce s wi ,J) i re7,a ;red / 64; /4 j Telephone No.: FOR OFFICE USE ONLY pa- I t0: ' 9/ DATE h f I PROJECT NAME Cam- aS I E TYPE OF REVISION: .* r -- Soz - 12-e SUBMITTED TO: CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * * REVISION SUBMITTAL * * N N � c t5 ADDRESS 4Z Z-o S I eY ti CONTACT PERSON -- 4-• fe (,`R_ PHONE ARCHITECT OR ENGINEER 1.. .jam' A C\ ts�T tr ! S— PERMIT NUMBER _ (If previously issued) n PLAN CHECK NUMBER Cie — 449 (ONO!TV N IE. u tz2 6.7Z VLA-to cle 5 Slav-Le b OZ. L � SHEET NUMBER(S) "Cloud" or highlight all areas of revisions and date revisions. CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUKWILA, WASHINGTON 98188 January 25, 1991 Ms. Christi Easter 4820 S. 150th St. Seattle, WA 98188 PHONE # (206) 433.1800 Cary L. VanDusen, Mayor RE: Site Address: 4820+ S. 150th St. - Easter Single Family Residence Request for Utility Permit Resubmital Dear Ms. Easter: The Public Works Department has reviewed the site plan for the above mentioned development, including revisions submitted 1/11/91, and requests that you resubmit the plan with the following additions /corrections: 1. WATER. Show water main and meter location. Please show the service from the house to the connection point on the main, and through the meter. The meter should not be located on adjoining private property. 2. SEWER. This property is served by Val Vue Sewer District. Please provide a written approval from a Val Vue official that the district has reviewed and approves the site plan, including pump location, size and type, and size and type of materials. 3. ACCESS. You will need to meet the access requirements of the Fire Department (20' all - weather driving surface, turnaround, and 13'6" vertical clearance). The access shown involves considerable cut in a steeply sloping area. Your plan must show a detailed typical section for this roadway, including the existing slopes above and below the cut, roadway slope (typically 2% into the hill) and surface (for stability of the slope a hard paved surface is appropriate), and provisions for disposal of the storm water runoff. This roadway design should be completed by a Professional Engineer, see comments for geotechnical report below. 4. STORM. Provide detention for site. Show drainage from roof, foundation, and all hard surfaced areas being directed to a public drainage system. Identify size, type and condition of public system to be used. If public drainage is not accessible, provide a design using infiltration, private drainage, etc., which insures downstream erosion or other property damage will not occur. There are a number of alternatives possible for this site, and the design should be performed by a Professional Engineer. See comments for Geotechnical Report below. 5. GRADE & FILL. It appears from the contours recently provided that cuts of greater that 5' and /or fills of more than 50 cubic yards. will be required for this development (proposed contours are not shown on your plan). This requires a permit under Chapter 70 of the Uniform Building Code. Please provide engineered yardage estimates of cut and fill, a grading plan (existing and proposed contours, sections where appropriate), and a soils and geology report which meet the requirements of Chapter 70 of the UBC. See comments for Geotechnical Report below. 6. GEOTECHNICAL REPORT. The City Council granted this property a waiver from the moratorium on development of sensitive areas on February 20, 1990. As a condition of that waiver, you are required to provide a geotechnical report. All of the above requirements may be meet by a single report. The report should include a review of all submitted plans (including a typical section for the access roadway, and drainage details and plans), notes and data from a site visit, and a soils and geology report per Chapter 70 UBC. The report must be signed and stamped by a State of Washington licensed professional engineer. 7. Please note on plan: Construction shall be in accordance with the City of Tukwila Public Works Department Standards. You will need to submit six copies of your revised plan to the Tukwila Permit Center. Your property is located in the service areas for Water District #125, and Val Vue Sewer District. Your will need to gain approval from these districts, in addition to meeting the City's standards, for your water and sewer services. If you have any questions, please feel free to call me at 431-3673. I look forward to hearing from you. Sincerel oss S. Heller, Associate Engineer RSH /arc xc: PW Read File, Dev. Files Single Family Denise Millard, Permit Coordinator • .■ FOR OF PHONE AREA 162 NUMBER DATE MESSAGE Ile,90/4" (PHONE/CA EXTENSION . -42j TI M E P12.0 0 i%Y.O.LIF,11. ALL you. CAU. , t0A11■1 METO ANTSIO: SEE Q TOPS to FORM 4003, CONVERSATION RECORD � DATE: / v2 % / 9 / MON WED U TIME, , /�'u PM' TYPE: ❑ Visit ❑ Conference Name of per ?" s) contacted • r in ct with you: Organ zat on (off ce,, i pt., • urea, etc. Location of Visit/Conference L2.t //4. SUMMARY: ,,a,„ Z• /tom elephone - (} Incoming toutgoing t) -;„ c1 (lc-) J .> FOR OFFICE USE ■5Y e /rte,/-. );K.J 7 4'1 61 Telephon 33 N 9 ' 0 x day Date: — / DATE: / / u g / 7 Afilikih.CONVERSATION RECORD C . TUE WED THU FR SAT SUN TIME: g Ara b TYPE: ❑ Visit ❑ Conference (s ' Telephone— O lncoming 0.0utgoing Name of 4w n(s) contacte in contact with you: Y Y V.�kr�. c C."'no L J Oh n) Organizat (office, dept., bureau, etc.) Location of Visit/Co erence: SUMMARY: A .Li IL -Ot r- D .4 A .C "L .0 / f Win, *IL Sru- -f ¢7711 4 1' e 9 Q 'f .ii AP ; �J(�?.�t L, ( I,e G - 11�f1)2.,�1__�t. �� J 8, a m.4_t4 a n1 l.' 3R) FOR OFFICE USE ONLY Telep ne No.: _ ��� PERMIT NUMBER a PLAN CHECK NUMBER -( 0 CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * * REVISION SUBMITTAL * * DATE //n /9 PROJECT NAME ADDRESS O SC /-56 441 :. %o / / V,� CONTACT PERSON (- /1" l PHONE ..- ''""n2 Q 7/F ARCHITECT OR ENGINEER // l I r T E Lg Lj L (If previously issued) RECEIVED CITY OF TUKWILA JAN 1 1 1991 PERMITCENTER TYPE OF REVISION: PLi(6(4 J (i0Y /1 5uPJ7J/ SHEET NUMBER(S) "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED TO: Pu ` U O(K ? City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review Control Number 90 -444 Re: John Easter - 4816 South 150th Dear Sir: Gary L. VanDusen, Mayor December 31, 1990 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Provide a copy of the easement for ingress and egress. 2. Every building shall be accessible to Fire Department apparatus by way of access roadways with all- weather driving surface of not less than 20' wide and 13'6" vertical clearance. Access roads in excess of 150' shall be provided with an approved turn - around area. Access shall be within 150' of all portions of the building. (UFC 10.207 as amended) Widen access driveway to the new home to 20'. Extend ingress- egress access to the property line to provide adequate hammerhead turn around for fire department apparatus. 3. Provide smoke detectors per U.B.C. 1210(A). 4. Provide a hydrant to within 150' of this home or sprinkle the home. Prior to installation of the sprinkler system, the contractor must submit 3 sets of plans to the fire department for approval. After sprinkler system installation, a functional test of the system is required. The system shall conform to the requirements of N.F.P,A. 13D. 5. Parking vehicles will not lie permitted on the required ingress- egress access road. -y�ji/ CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * * REVISION SUBMITTAL * * DATE i ?)�gd PROJECT NAME ) C T ADDRESS 1 , ,) -() �i <ti /`.7 CJ 4/ A C O N T A C T PERSON C-N 1 S f / PHONE 4 / ARCHITECT OR ENGINEER PERMIT NUMBER ?(;) � ii / / 1 "( (If previously issued) PLAN CHECK NUMBER 4/ TYPE OF REVISION: f L/), 5 &Z) PM/JS SHEET NUMBER(S) "Cloud" or highlight all areas of revisions and date revisions. SUBM1Tt'LD TO: KEW I ' s'F,V RECCIVCD CITY OF TI IKWII.A 0EC 1 7 1990 PERMIT CENTER November 9, 1990 CITY OF TUKWILA 6200 SOUTNCENTER BOULEVARD, TUKWILA, WASHINGTON 98188 John Easter 4820 S. 150 th Seattle, WA 98112 RE: New Residence, 4816 S. 150 th Plan check number 90 -444 Dear Mr. Easter: I4/ONE N1206)433.1800 Cary h. VanOusen, Mayor After an initial review of subject project, it has been determined that additional information typical to plans and corrections be submitted to complete the plan review. Please address the following comments. 1. General Notes to reflect conformance to 1988 U.B.C. and the Washington State Energy Code. v/2. Submitted foundation plan indicates 6 inch foundation walls \lit; are proposed, this is inadequate per U.B.C. table 29 -A, 8 inch would be required to support two stories. v' 3. Provide cross section details of foundation showing any ��I�1"�' steel requirements. Walls 48 inches and greater in height E �� require additional steel reinforcing. Provide pier sizes on plans that support 4 x 4 posts and bracing detail of post to beam, for decks and crawl space. V 5. Provide ventilation to crawl space 1 sq.ft. net opening per 150 sq.ft. area U.B.C. 2516 (f). ,6. Provide detail to show one -hour fire resistance between garage and dwelling U.B.C. 503 (d). v'7. Provide location of smoke detectors U.B.C. 1210 (a). , /8. Provide mechanical ventilation to bathrooms U.B.C. 1205. % 9. Provide details on floor plan of any proposed utility rooms. - Provide location of hot water tank and furnace. Page 2 Sincerely Ken Nelsen Plans Examiner 11. What is the heat type ? Gas, electric ? x /"12. Provide location of under floor access per U.B.C. 2516 (c). 13. Provide location of attic access minimum 22" x 30" U.B.C. 710 (g). ‘ ,/14. Provide minimum one exit door not less than 3 ft. per U.B.C. 3304 (a) and (f). ✓15. Provide out side combustion air to fire place per U.M.C.. .0 Provide on details attic ventilation 1/150 of the area per U.B.C. 3205(c). \ /17. All sleeping rooms escape windows require a minimum clear height of 24 inches and width of 20 inches U.B.C. 1204. 08. Provide chimney height 2 ft. above 10 ft. horizontal. (19\ Provide sq. ft. total glass area calculation not to exceed 21% of total floor per Washington State Energy Code. Contact me if there are any questions on these comments, 8130 a.m. to 4:30 p.m. at 431 -3670. r' CITY OI% T UKWILA 6gun SOUTIICIiN7ERBOULEVARD, TUKWII.A, IVASIIINGTON9x188 November 8, 1990 Ms. Christi Easter 4820 S. 150th St. Seattle, WA. 98188 RE: Site Address: 4820+ S. 150th St. - Easter Single Family Residence Request for Utility Permit Resubmittal Dear Ms. Easter: I'IIONli 11 (2(16) 43 :1 1800 The Public Works Department has reviewed the site plan for the above mentioned development, and requests that you resubmit the plan with the following additions /corrections: 1. TOPO. Show existing and proposed 2 foot contour lines. 2. WATER. Show water main and meter location. Identify materials to be used. Note 18" minimum cover over all pipes. Provide a copy of the required easement. 4. SEWER. Provide a design, stamped by a Licensed Professional Engineer, for the sanitary sewer pump. Provide a copy of the required easement. 5. ACCESS. Identify access as existing or proposed, and show paved surface extending a minimum of 10' from existing roadway. Identify access slope (maximum 15 %). Provide a copy of the easement and maintenance agreements for shared access. 6. STORM. Show drainage from roof, foundation, and all hard surfaced areas being directed to a public drainage system. Identify size, type and condition of public system to be used. If public drainage is not accessible, provide an infiltration design, stamped by a Licensed Professional Engineer. Provide a copy of easement, where required. 7. Note on plan: Construction shall be in accordance with the City of Tukwila Public Works Department Standards. You will need to submit six copies of your revised plan to the Tukwila Permit Center. Cnry L. ! irnl)usr,i. Moor } Your property is located in the service areas of Water District #125, and Val Vue Sewer District. You will need to gain approval of your proposed sewer and water connections and provide Certificates of Availability from these districts for your water and sewer services as part of your resubmittal. You must also meet City of Tukwila Standards, which is the basis for the above requests. I have attached a typical site plan of a single family home for your reference. If you have any questions, please feel free to call me at 431 -3673. I look forward to hearing from you. Sincerely Ross S. e ller Associat Engineer xc: Read File, Dev. File: Single Family Denise Millard, Permit Coordinator RSH /arc:RSH06 =Easter • July 10, 1990 John & Christi Easter 4820 South 150th Street Tukwila, Washington 98188 Re: Development of Lots B and C at 4820 South 150th Street Dear Mr. & Mrs. Easter: Your letter requesting to be allowed to install sprinkler systems in the homes proposed for lots E and C at 4820 South 150th Street, in lieu of installing a fire hydrant, is acceptable. As noted in your letter, plans for the sprinkler system need to be approved by The Tukwila Fire Department prior to installation. In addition, you will need to provide a copy of the ingress - egress easement prior to plan approval by the fire department. The access road to lots B & C is required to be 20 feet wide with an all weather surface. Access roads in excess of 150 feet must have adequate turn arounds (for each house) for fire department apparatus. If you have any questions pertaining to these matters, please contact me. Sincerely, 6041 City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Nick Olivas Assistant Chief /Fire Marshal cc: Darren Wilson - Planning Department NJO:ncd Gary L. VanDusen, Mayor • BUILDING COMPONENT DESCRIPTION INCLUDING U -VALUE OR F -VALUE Single (U =1.20 ) HEAT LOSS FACTOR (HLF = U x 46 A t) 55.2/SF 41.4 /SF 34.5/SF 27.6/SF 23.0 /SF 18.4 /SF /SF 21.6 /SF 14.7 /SF 9.2 /SF /SF 18.4 /SF 2.5 /SF 1.6 /SF 1.2 /SF 0.9 /SF /SF 11.5 /SF 6.4 /SF 3.7 /SF 5.1 /SF 2.4 /SF 1.7 /SF /SF 11.5 /SF 3.7 /SF 2.5 /SF 1.6 /SF /SF 37.3/LF 28.1/LF 25.8/LF 24.8/LF /LF 1.5 /SF /SF 1.0 /CF 0.5 /CF COMPONENT SQUARE FT(SF) LINEAR FT(LF) CUBIC Ft (CF) x SF COMPONENT HEAT LOSS (HLF x SF, LF or CF) = Btuh A. Window, Skylight, Sliding Glass Door . Double,untested (U =0.90 ) x SF = Btuh AAMA- tested (U =0.75 ) x 2,41 SF = msya Btuh = Btuh AAMA - tested (U =0.60 ) x SF AAMA- tested (U =0.50 ) x SF = Btuh AAMA- tested (U =0.40 ) x SF = Btuh Other (U= ) x SF = Btuh B. Opaque Door Wood (U =0.47 ) x •j-o SF = poy. Btuh W /storm door (U =0.32 ) x SF = Btuh Insulated metal (U =0.20 ) x SF = Btuh Other (U= ) x • SF = Btuh C. Roof/ Ceiling Insulation None (U =0.40 ) x SF = Btuh R -19 U =0.055 x SF = Btuh R -30 (U= 0.035) x SF = • Btuh R -38 (U= 0.026) x X6'0 SF = ii,s -%2 Btuh R -49 (U= 0.020) x SF = Btuh R- (U= ) x SF = Btuh D. Wall Insulation (above and below grade) ' None (U =0.25 x SF = Btuh R- 11,metal stud (U =0.14 ) x SF = Btuh R- 11,wood studs (U =0.08 ) x SF = Btuh R- 19,metal stud (U =0 1 ) x SF = Btuh R- 19,wood studs (U= 0.053) x / ;;-/ SF = 1.,vy.7 Btuh = Btuh R- 27,wood studs (U= 0.037) x SF R- (U= ) x SF = Btuh E. Floor Over Unheated Space Insulation None (U =0.25 ) x SF = Btuh R -11 (U =0.08 ) x SF = Btuh R -19 (U= 0.055) x ode o SF = .,q..00 Btuh R -30 (U= 0.035) x SF = Btuh R- (U= ) x SF = Btuh = Btuh F. Slab On Grade • Floor Perimeter Insulation None (F =0.81 ) x LF R -5 (F =0.61 ) x LF = Btuh R -8 (F =0.56 ) x LF = Btuh R -10 (F =0.54 ) x LF = Btuh R- (F= ) x LF = Btuh G. Basement Floor None (F= 0.032) x to SF = x a Btuh R- (F= ) x SF = Btuh H. Infiltra- tion Pre 1980 (.018x1.2 ACH) x CF = Btuh Post 1980 (.018x0.6 ACH) x CF = Btuh TOTAL= Design If electric, Divide (DHL) Space Heating Minimum required Maximum allowed Proposed (For gas -and oil Heating Load. (DHL) in•Btuh = • divide by 3.413 for DHL in watts = by ( / g y- & Heated floor area)= c7.. C7 Btuh or Watts /750$ Btuh b 33 Watts square foot Btuh or watts Btuh or watts Btuh or. watts Equipment Sizing Limits equipment size = OHL x 1.0 = equipment size = DHL x 1.5 = equipment size (Output) = -fired equipment exceeding 150% of DHL, j ?5'o f; ? �, ;46 2 a5 see reverse) . . 15 DEPARTMENT OF CONSTRUCTION AND LAND USE Project Address: ''- a c5 ! S� �� �' =.7f / �- 6u.4 SEATTLE ENERGY CODE DESIGN HEATING LOAD (D Date of this submittal: EQUIPMENT SIZING CALCULATION FORM Project Number: March 1988 Instructions: See reverse. EN11 /hlc.1 -2 rr o Permit Number: RECEIVED CITY OF TUKWILA (! I. 1 ti 1! : PERMIT CENTER INSTRUCTIONS FPR DESIGN HEATING LOAD & EQUIPMENT SIZING CALCULATION FORM , ; Proposed output (must be 56,000 Btuh or less) = General Information This form is recommended for sizing the heating systems for all residential buildings. It may be used for commercial buildings where appropriate. This form, or acceptable alternate calculations, must be completed for each dwelling unit. A separate copy shall be attached to each set of drawings submitted with the building permit application. If you have any questions, please call the Department of Construction and Land Use at 684 -8860, between 10:30 a.m. and 4:30 p.m. If new or enlarged electric service is to be installed in an existing building, you may be subject to additional requirements in the Seattle City Light efficiency standards. For further information, contact Seattle City Light at 684 -4220 if the project is north of Mercer Street or 386 -1600 if the project is south of Mercer Street. Detailed Instructions For existing buildings, complete for each dwelling unit as proposed after remodeling. If space heating equipment is simply being replaced, complete for the dwelling unit as existing. For new construction, complete for each dwelling unit as proposed. On the line with the appropriate description, enter the proposed design square footage for windows, skylights, sliding glass doors, opaque doors, roof /ceiling, wall, floor over unheated space and basement floor (more than one foot below grade). Enter linear feet of perimeter for slab -on -grade floor (less than one foot below grade). Under infiltration, enter the volume of the interior heated space in cubic feet on the appropriate line based on when the dwelling unit or portion thereof was or will be built. For glazing and doors, where U- values different from those specified are used, enter those U- values in the blanks provided for that category. For other components, where R- values different from those specified are used, enter that value and the corresponding U -value or • F -value in the blanks provided in that category. For all new entries, multiply the U -value or F -value by the 46 °F. design temperature difference (70 °F. - 24 °F.) to obtain the corresponding heat loss factor and enter that value in the heat loss factor column. Multiply the heat loss factor by the component square feet (sq.ft.), linear feet (lin.ft.) or cubic feet (cu.ft.), as appropriate to obtain the component heat loss. Add all entries to obtain the total which is the Design Heating Load (DHL). Divide the DHL by the heated floor are to obtain the load on a square foot basis. Multiply Design Heating Load (in either Btuh or watts) by 1.0 and by 1.5 obtain minimum and maximum equipment sizes allowed. Commercial buildings have no minimum requirements. Enter proposed equipment size (output) and verify that it is within the limits calculated. For gas- and oil -fired equipment, the optional calculation procedure may be used. Subtract the Design Heating Load (DHL) from the proposed output size. Divide this figure by 5000. Then, add the result to 74 to determine the minimum AFUE required. OPTIONAL -NOT REQUIRED: Applicable only to gas- and oil -fired equipment. For gas- and oil -fired equipment with total rated output in one dwelling unit of 56,000 Btuh or less, the maximum allowed equipment size may exceed:150% if the equipment has a higher minimum AFUE as calculated below: . Minimum required AFUE 74 + ( • output) -( • DHL) 5000 Btuh' EC11 /hl c -marl 880222 Btuh % AFUE • BUILDING COMPONENT DESCRIPTION INCLUDING U -VALUE OR F -VALUE HEAT LOSS FACTOR (HLF = U x 46°&t) COMPONENT SQUARE FT(SF) LINEAR FT(LF) CUBIC Ft (CF) COMPONENT HEAT LOSS (HLF x SF, LF or CF) A. window, Skylight, Sliding Glass Door . Single (U =1.20 ) 55.2 S 41.4 /SF 34.5/SF 27.6/SF 23.0 /SF 18.4 /SF /SF 21.6/SF 14.7 /SF 9.2 /SF /SF 18.4 /SF 2.5 /SF 1.6 /SF 1.2 /SF 0.9 /SF /SF 11.5 /SF 6.4 /SF 3.7 /SF 5.1 /SF 2.4 /SF 1.7 /SF /SF 11.5 /SF 3.7 /SF 2.5 /SF 1.6 /SF /SF 37.3/LF 28.1 /LF 25.8/LF x = Btuh Double,untested (U =0.90 ) x SF = Btuh AAMA- tested (U =0.75 ) x '2,9-9 SF = ( #15 Btuh AAMA- tested (U =0.60 ) x SF = Btuh AAMA tested (U =0.50 ) x SF = Btuh AAMA- tested (U =0.40 ) x SF = Btuh Other (U= ) x SF = Btuh B. Opaque Door Wood (U =0.47 ) x Lt-0 SF = S?‘ 4 f Btuh W /storm door (U =0.32 ) x SF = Btuh Insulated metal (U =0.20 ) x SF = Btuh Other (U= . ) x SF = Btuh C. Roof/ Ceiling Insulation None (U =0.40 ) x SF = Btuh R -19 (U= 0.055) x SF = Btuh R -30 (U= 0.035) x SF = Btuh R -38 (U= 0.026) x a'o SF = ,,rr Btuh R -49 (U= 0.020) x SF = Btuh R- (U= ) x SF = Btuh D. Wall Insulation (above and below grade) ' None (U =0.25 ) x SF = Btuh R- 11,metal stud (U =0.14 ) x SF = Btuh 11 studs (1=0.08 ) x SF = Btuh R- 19,metal stud (U=0.11 ) x SF = Btuh R- 19,wood studs (U= 0.053) x i s' '/ SF = 4..i 4.2„ Btuh . R•- 27,wood studs (U= 0.037) x SF = Btuh R- (U= ) x SF = Btuh E. Floor Over Unheated Space Insulation None (U =0.25 ) x SF = Btuh R -11 (U =0.08 ) x SF = Btuh R -19 (U= 0.055) x le.-44a SF = poo Btuh R -30 (U= 0.035) x SF = Btuh R- (U= ) x SF = Btuh F. Slab On Grade Floor Perimeter Insulation None (F =0.81 ) x LF = Btuh R -5 (F =0.61 ) x LF = Btuh R -8 (F =0.56 ) x LF = Btuh R -10 (F =0.54 ) 24.8/LF /LF 1.5 /SF /SF 1.0 /CF 0.5 /CF x LF = Btuh R- (F= ) x LF = Btuh G. Basement Floor None (F= 0.032) x 4 1-o SF = 6b Btuh R- (F= ) x SF = Btuh H. Infiltra- tion Pre 1980 (.018x1.2 ACH) x CF = Btuh Post 1980 (.018x0.6 ACH) x CF = Btuh TOTAL= Design If electric, Divide (DHL) Space Heating Minimum Maximum Proposed (For gas -and Heating Load (DHL) in Btuh = - divide by 3.413 for DHL in watts = by ( Heated floor area)= 7 Btuh or Watts/square 7 7b g Btuh 5� o Watts foot Btuh or watts Btuh or watts Btuh or watts Equipment Sizing Limits required equipment size = DHL x 1.0 = allowed equipment size = DHL x 1.5 = equipment size (Output) _ oil -fired equipment exceeding 150% of DHL, / 75 _262_62_ agv o o see reverse) 6 DEPARTMENT OF CONSTRUCTION AND LAND USE Project Address: SEATTLE ENERGY CODE DESIGN HEATING LOAD AND Date of this submittal: EQUIPMENT SIZING CALCULATION FORM March 1988 Instructions: See reverse. EN11 /hlc.1 -2 Project Number: 6TH Permit Number: g) J C RECEIVED CITY OF TUKWILA OCT 2 6 11)X(1 PERMIT CENTER INSTRUCTIONS F0 gESIGN HEATING LOAD & EQUIPMENT= TZING CALCULATION FORM General Information This form is recommended for sizing the heating systems for all residential buildings. It may be used for commercial buildings where appropriate. This form, or acceptable alternate calculations, must be completed for each dwelling unit. A separate copy shall be attached to each set of drawings submitted with the building permit application. If you have any questions, please call the Department of Construction and Land Use at 684 -8860, between 10:30 a.m. and 4:30 p.m. If new or enlarged electric service is to be installed in an existing building, you may be subject to additional requirements in the Seattle City Light efficiency standards. For further information, contact Seattle City Light at 684 -4220 if the project is north of Mercer Street or 386 -1600 if the project is south of Mercer Street. Detailed Instructions For existing buildings, complete for each dwelling unit as proposed after remodeling. If space heating equipment is simply being replaced, complete for the dwelling unit as existing., For new construction, complete for each dwelling unit as proposed. On the line with the appropriate description, enter the proposed design square footage for windows, skylights, sliding glass doors, opaque doors, roof /ceiling, wall, floor over unheated space and basement floor (more than one foot below grade). Enter linear feet of perimeter for slab -on -grade floor (less than one foot below grade). Under infiltration, enter the volume of the interior heated space in cubic feet on the appropriate line based on when the dwelling unit or portion thereof was or will be built. For glazing and doors, where U- values different from those specified are used, enter those U- values in the blanks provided for that category. For other components, where R- values different from those specified are used, enter that value and the corresponding U -value or F -value in the blanks provided in that category. For all new entries, multiply the U -value or F -value by the 46 °F. design temperature difference (70 °F. - 24 °F.) to obtain the corresponding heat,.,loss factor and enter that value in the heat loss factor columh. Multiply the heat loss factor by the component square feet (sq.ft.), linear feet (lin.ft.) or cubic feet (cu.ft.), as appropriate to obtain the component heat loss. Add all entries to obtain•the total which is the Design Heating Load (DHL). Divide the DHL by the heated floor are to obtain the load on a square foot basis. Multiply Design Heating Load (in either Btuh or watts) by 1.0 and by 1.5 obtain minimum and maximum equipment sizes allowed. Commercial buildings have no minimum requirements. Enter proposed equipment size (output) and verify that it is within the limits calculated. For gas- and oil -fired equipment, the optional calculation procedure may be used. Subtract the Design Heating Load (DHL) from the proposed output size. Divide this figure by 5000. Then, add the result to 74 to determine the minimum AFUE required. OPTIONAL -NOT REQUIRED: Applicable only to gas- and oil -fired equipment. For gas- and oil -fired equipment with total rated output in one dwelling unit of 56,000 Btuh or less, the maximum 'allowed equipment size may exceed 150% if the equipment has a higher minimum AFUE as calculated below: . Proposed output (must be 56,000 Btuh or less) = Btuh Minimum required AFUE = 74 + ( output) -( DHL) _ 5000 Btuh EC11 /hlc -marl 880222 % AFUE Imo PROJECT . `� 77 ADDRESS DATE 11 �� G CITY OP mom.. u rv,i.o. • prepared by: PLAN CNECK NUMBER Plan Review PROJECT ADDRESS DATE OCCUPANT LOAD EXITING REQUIREMENTS ICe 5 l 5O 2..1 OCCUPANCY GROUP 1 �'" � \OL)SE TYPE OF CONSTRUCTION ..._ _ 1% '% Se. \- `-- Re.f) LOCATION ON PROPERTY (:'1 Q0‘-k- sr BUILDING HT. / NO. STORIES 2 - FLOOR AREA 1 8 Li o rit Q. Peel _)x® DETAILED REQUIREMENTS OCCUPANCY TYPE OF CONSTRUCTION PART V, CHAPTER 23, U.B.C. W.S.E.C. CHAPTER 51 -10, W.A.C. o AIL IMP CITY OF TUK `YI LA DEPARTM &NT OP COMM ''Y DEVELOPMENT prepared by [ NUMB ER W CHECK 0 - Lk ut , Regular Council Meeting February 20,1990 Page 7 Waiver Request (con's* Craig Hittle Request for Waiver of Ordinance #1544 - Mike and Christi Easter N BUSINF c South King County Transportation Benefit District MOVED BY EKBERG, SECONDED BY ROBERTSON, TO APPROVE THE WAIVER SO THAT A BUILDING PERMIT MAY BE PROCESSED CONDITIONAL ON A GEOTECHNICAL STUDY BEING DONE.* Councilman Robertson asked Councilman Ekberg's reason for making this waiver more specific than the other waivers in that you have requested the geotechnical study done prior to the building permit. Councilman Ekberg responded that the one considered before Mr. Hittle's was generally a flat piece of roperty with a 15 degree slope in one corner. Here there is a piece of property that is between a 15 percent grade and a 40 percent grade. *MOTION CARRIED WITH DUFFIE VOTING NO. WAIVER IS GRANTED WITH CONDITIONS. Mike Easter addressed the Council with his proposal to build two single family homes at 4820 So. 150th Street. He noted that there are no large trees on the property. The houses would be built on what is now a pasture. In response to Council President Hernandez' question of urgency, he noted that to wait until after the moratorium expires, he will lose the ability to schedule sub - contractors for early summer and the interest rate is unstable. Councilman Moriwaki asked Mr. Easter if he would be willing to conform with the adopted SAO at his own risk and expense. Mr. Easter replied that regarding surface water management, he had assumed that he would have to put in some type of infiltration system to handle the downspouts. He commented that he wouldn't mind creating some water diversion or more extensive infiltration type systems, but if he has to put in a.400 foot storm drain, he might want to apply for some help. He stated.he would be willing to take care of any water he personally diverted. MOVED BY MORTWAKI, SECONDED BY DUFFIE, THAT A WAIVER BE GRANTED SUBJECT TO THE PETITIONER FILING AN AGREEMENT TO CONFORM TO THE ADOPTED SENSITIVE AREAS ORDINANCE AND TO PROCESS APPLICATIONS AT HIS OWN RISK AND EXPENSE. MOTION CARRIED. Director of Community Develop Rick Beeler noted that Council did not impose the condition subject to the petitioner filing an agreement on Mr. Hittle's waiver request as with the other requests, but they did impose the geotechnical study. Councilman Robertson stated that when he seconded the motion, he did it with the intent and understanding that it was similar to all the other waivers we have granted with the exception that it had an additional item to it, and that was that they had to do a geotechnical report. Council concurred with Councilman Robertson. Councilman Robertson reported on the SKCTBD. He commented that it is beneficial to the City to join in this program, and there is a very low risk in the way it is set up to start. To get the "flexible" TBD goinng we will make public notice but not a mailing to everyone. The TBD cannot issue debt to start with. Therefore, it is fairly low risk at this point. We can modify the boundaries or get out of it easily. Our commitment at this time will help to hire an administrator and a consultant to put together a project list. We will also be able to finalize the rules as to how the' flexible" TBD would work. Tukwila's commitment is only $8,000 and we can back out at any time. After the O tt year, all of the jurisdictions may decide to jointly go into a "strict D. The undersigned owner and developer of real property located at It.74 2 0 h and more specifically described in Exhibit A attached hereto, hereby agrees, pursuant to the requirements of Tukwila Ordinance .No.'s 1544.and 1550, that if the City of Tukwila will process the following . applications: `/i5/90 Agreement To Be Subject To A Sensitive Areas Ordinance R.. the development of the property described in Exhibit A will be subject to all of the Sensitive Areas Ordinance provisions as finally pa 'sed by the City Council even though those provisions may be more restrictive than any conditions or limitations imposed by or resulting from the processes described above. The Undersigned agree(s) that these processes will be continued solely at their risk and expense and that the result of the final Sensitive Area Ordinance may be to require extensive project modification and re- evaluation or recision of the above . approvals. It is also understood and agreed that continuation of these processes does not mean that applications not pending on November 20, 1989, for this project, will be accepted or processed unless the. City Council approves a petition therefor. The undersigned acknowledges that the covenants herein run with the land described in Exhibit A and that this document will be recorded with the Ring County Department of Records and Elections and that these covenants cannot be released without the written consent of the City of Tukwila. Applicant STATE OF WASHINGTON ) ) ss. COUNTY OF KING ) On this day personally appeared before me . - 56\n/ to me known to be the individual described in and who executed this instrument, and acknowledged that s /he signed the same as a free and voluntary act for the uses and purposes herein mentioned.. Dated � r: 1 1 ? � , 1990. • Notary Public in and State of Washington, at 'f"rl 9 �?' appointment expires for the residing �' My ��Z ^9v s � ,moo y e o-F bu'I lcPl / 84 , 6 3 . Pc r, I / - ) .5 • u as / c u e 0 aN /c -c. JcJt o ,)w...t t'�tizc� . / 9 p c L ©n ir c- 7 1- 0 I'S /D 0 c Cca c a /ut ah _62 h /8/-8 RECEIVED CITY OF TIUKWIlA OCT 2 0 1990 PERMIT CENTER (.) w 0e-3c. -Q ? 01 ran e 5'0 _ 7 0 A _se = �ut fc)shy �rrrrrr Fec. SScf . aG /a n Ch «h Fe c 3 6 3- .� S14? Baifcti1 Jtr Chaavye `F - .3 7. 5./ s, ? X /c§ cf = ' `t' /3.3_ ��' ge.411d rn / c- P /ter? CIrC/r Fie 5carchcarf' (coo.. o" 3 .2 5 9 - - 5-c:' /b ce/ 82 q.s° rr new .water lines • 4 .:selKvhdc I m .ceuer .6.10.4,;.. ..finilb _0 rode 1 • • 1 , • • 4 t . - • • • .C.G i�Jii3 1 1 , wK nCrt Groten►1y eatomr,ti narraJ here $su /dsr .0.grrt$ i.q els n_patXemce7 '. 1.•v_ ._ •a---wietth - -_ �n�f6is. _area_ _ fCW rn.he�nen'f in ro•.4 c not a AtlA'ter 1 UndcroroypN poi + WtR"t exl5 ! I I LG .O r'e�eru'1 pc n�aKy nFritii:113A.`6a•1•∎• .er - +'r�lVA1�:klw J: i.: 312( 5Aseih5WT 1 •i Propel-1'y Tax Atcounf 4' oo'- 2.0 - o/so -08 s ea„a9e 1-0 be pur+npc c. tier-11.4i r.lst a p pro )4 12' 3/0 -__ 5 -D .. . . , . -y -• r rte • ., r LEGAL IIESCRIPTtofS : • tefore the Short subdivision: Lots 14 and 15, Block 2, Second Addition to Adana' Home Tracts, according to the.plat the recorded in Vulvae 12 of Plats, page 90, in Wing County, Washington; • EXCEPT *be wet 111.4 beet of said yot,15; • ' BJJBJECT TO in easement for ingrain, 'egz•ese ; and utilities ` over:tbe east 30 ' _thereof.. Aural 'C: Lots 3.4 and + 15, Bloek 2, Second Addition to Adams' Home Tracts, according to p recorded in Volume 12 of flats, pegs 90, in King County, Washington; $(EPT the south 2 A thereof and PT the wept 111.4,0 of maid 'Lot '15i TOGETHER WITH an easement for sewer the east 10' of the west 121.40' atlhe south,2t}b; of said Lot 15;' SUBJECT TO AM TOTE an easement for ingress, egress and utilities over the east 30' of paid Lot 14. After the short subdivision: Parcel A: The s' w1;E 182' of Lots 14 and 15, Slock 2, Second Addition to Home'Trac according to plat recorded in Volume 12 of Plats, page 90, in King County, Washington; EXCEPT the west L 1.40' said Lot 15; SUBJECT TO and easement for ingress, egress and over the east 30' thereof and SUBJECT TO and easement for sewer over the west3D' thereo • Parcel $: The north '6b" of the south 24p' of Lots 14 and 15, Block 2, Second Addition to Home Tracts, according to plat recorded in Volume 12 of- Plats, page 90, in King County, EXCEPT.the.west.LU.40'. of said Lot 15; SUBJECT TO AND TOGETHER WITH an easement for ing ;egress and utilities over 'the east '3O' of the south 24s'' 'o'f .said Lot l4; `- ' `'': ''. SUBJECT TO AHD 'TOGETHER WITH an easement for sewer over the east 10' of the west 121.40' south '24f•' of said Lot 15. Parcel C: (see above) 1ti_�e__SI� 4 3 ._ A� ��11J flnfe --Pr_Ppgr_ri . Drty ei..%ay For Lets 3 t c._ w P4 sMrittte sx •endiJ in to' from maihtsni+ncv rive 4 dc*. - z`4? bs Proposed /Loans /So" 51 121.4. net re5perW 4/l FLEXIBLE RULER -302 AW.. It iz s __rutr_�r_ 2t e /euafioq. ._ _._._.___ .Iy. tYe.. M - I '1 I g 1 ' T� II� 5 1 II�11 1 ` � I T I ��I���I�I�f I � I h I ��I�� I I�� r j � ` � ' irip 1'011 1 11 I' I i.rhnHCH --1' 2 3 4 5 I 6 I 7 1rifLlfraiton sysfry, . -3cc __deter: SGaIC ...732 a •/ 8 10E 6Z Be LZ 9Z se 1 /7.1 CZ ZZ IZ OZ 61 81 LI 91 SI VI el ZI II 01. . 611► 41116IIIIIIIIIII 11141644440u40IIII 11011 pI�� l40401uIJ441I4,IIjILl P1 61I►►Ll66v6114011106H44 fj / 4 ' • itiee P/1 . • • ,.....- 11•. A • IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, IT IS DUE TO `iTHE QUALITY OF THE ORIGINAL DOCUMENT` Ai- s /•pe A - I p /en / sue* �"u /WP+ Felu nda t ic,, t 7 f►,amins EMu.(74ens E /cNn ttottr 2.nd r-/oar 4. Roof fra',imp 4 its ft./ •1Ore l oos col �vcucwa CCt• APPR LETTE DAB DR PUBLIC WORKS RECEIVED APR 2 21991 TUKWILA PUBLIC WORKS • M • • Co o W Cn efkbenweert' o /// t LOT $ / / �\ ile ,� -- Sewer' I t /r /• E�� __ __ LOT A _ - �tepoloP._lerhr_ntek —_�„ J / Lor 7 � 20 I • 4.1c.) -2.8' I _ jr ..----. rr new .water lines • 4 .:selKvhdc I m .ceuer .6.10.4,;.. ..finilb _0 rode 1 • • 1 , • • 4 t . - • • • .C.G i�Jii3 1 1 , wK nCrt Groten►1y eatomr,ti narraJ here $su /dsr .0.grrt$ i.q els n_patXemce7 '. 1.•v_ ._ •a---wietth - -_ �n�f6is. _area_ _ fCW rn.he�nen'f in ro•.4 c not a AtlA'ter 1 UndcroroypN poi + WtR"t exl5 ! I I LG .O r'e�eru'1 pc n�aKy nFritii:113A.`6a•1•∎• .er - +'r�lVA1�:klw J: i.: 312( 5Aseih5WT 1 •i Propel-1'y Tax Atcounf 4' oo'- 2.0 - o/so -08 s ea„a9e 1-0 be pur+npc c. tier-11.4i r.lst a p pro )4 12' 3/0 -__ 5 -D .. . . , . -y -• r rte • ., r LEGAL IIESCRIPTtofS : • tefore the Short subdivision: Lots 14 and 15, Block 2, Second Addition to Adana' Home Tracts, according to the.plat the recorded in Vulvae 12 of Plats, page 90, in Wing County, Washington; • EXCEPT *be wet 111.4 beet of said yot,15; • ' BJJBJECT TO in easement for ingrain, 'egz•ese ; and utilities ` over:tbe east 30 ' _thereof.. Aural 'C: Lots 3.4 and + 15, Bloek 2, Second Addition to Adams' Home Tracts, according to p recorded in Volume 12 of flats, pegs 90, in King County, Washington; $(EPT the south 2 A thereof and PT the wept 111.4,0 of maid 'Lot '15i TOGETHER WITH an easement for sewer the east 10' of the west 121.40' atlhe south,2t}b; of said Lot 15;' SUBJECT TO AM TOTE an easement for ingress, egress and utilities over the east 30' of paid Lot 14. After the short subdivision: Parcel A: The s' w1;E 182' of Lots 14 and 15, Slock 2, Second Addition to Home'Trac according to plat recorded in Volume 12 of Plats, page 90, in King County, Washington; EXCEPT the west L 1.40' said Lot 15; SUBJECT TO and easement for ingress, egress and over the east 30' thereof and SUBJECT TO and easement for sewer over the west3D' thereo • Parcel $: The north '6b" of the south 24p' of Lots 14 and 15, Block 2, Second Addition to Home Tracts, according to plat recorded in Volume 12 of- Plats, page 90, in King County, EXCEPT.the.west.LU.40'. of said Lot 15; SUBJECT TO AND TOGETHER WITH an easement for ing ;egress and utilities over 'the east '3O' of the south 24s'' 'o'f .said Lot l4; `- ' `'': ''. SUBJECT TO AHD 'TOGETHER WITH an easement for sewer over the east 10' of the west 121.40' south '24f•' of said Lot 15. Parcel C: (see above) 1ti_�e__SI� 4 3 ._ A� ��11J flnfe --Pr_Ppgr_ri . Drty ei..%ay For Lets 3 t c._ w P4 sMrittte sx •endiJ in to' from maihtsni+ncv rive 4 dc*. - z`4? bs Proposed /Loans /So" 51 121.4. net re5perW 4/l FLEXIBLE RULER -302 AW.. It iz s __rutr_�r_ 2t e /euafioq. ._ _._._.___ .Iy. tYe.. M - I '1 I g 1 ' T� II� 5 1 II�11 1 ` � I T I ��I���I�I�f I � I h I ��I�� I I�� r j � ` � ' irip 1'011 1 11 I' I i.rhnHCH --1' 2 3 4 5 I 6 I 7 1rifLlfraiton sysfry, . -3cc __deter: SGaIC ...732 a •/ 8 10E 6Z Be LZ 9Z se 1 /7.1 CZ ZZ IZ OZ 61 81 LI 91 SI VI el ZI II 01. . 611► 41116IIIIIIIIIII 11141644440u40IIII 11011 pI�� l40401uIJ441I4,IIjILl P1 61I►►Ll66v6114011106H44 fj / 4 ' • itiee P/1 . • • ,.....- 11•. A • IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, IT IS DUE TO `iTHE QUALITY OF THE ORIGINAL DOCUMENT` Ai- s /•pe A - I p /en / sue* �"u /WP+ Felu nda t ic,, t 7 f►,amins EMu.(74ens E /cNn ttottr 2.nd r-/oar 4. Roof fra',imp 4 its ft./ •1Ore l oos col �vcucwa CCt• APPR LETTE DAB DR PUBLIC WORKS RECEIVED APR 2 21991 TUKWILA PUBLIC WORKS • M • • Co o W Cn , S. /so"' RECEIVED APR 2 2 1991 1 unwflA PUBLIC WORKS I I I I 1‘ 11 I 11 , citemagt 1 _ rvl ty fl from here iv " -7sf. .retin 3e ' .67•3/1 'rade' appro. eci et y e r ( S r-carr...4 rim "_ /mrs 'rye ,I_, _ .ao .6 Sow o-a _than_ouis _eux f rope', r• tnttliffruf761 cfrfaill 1-11;s pctye c/ 4.. ft s , 4 Mini I fill OP 11 I 11 I I p 1 19 1 IT INITITI I 11' 11111 p 1110431/1CM -1' 2 3 4 5 6 7 8 FLEXIBLE RULER -302 . ;OE 6Z 8C L 9 CZ Ze 18 0? 61 Ell LI 91 SI VI CI ZI 11 01. I 11 1 111 11 11111111111111111111111 4 111 1 1111 1 111 1 11 11 1 1 11111 11 1 11 1111 1 11 01 1 1 1111 1111 1 1 1 1 1 111111111111111)1111141111111i1116111111411111111111111P11144111111611111111 ' o //rcl-‘; 41.je j -es. _ hiAthrie r esop to I/ irAl 014 SC4/C. aJ r in f rAh.n p hc.y,..4 h&ose ibar. .rPezf reci toocr _4 ' IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, IT IS DUE TO t THE QUALITY OF THE ORIGINAL DOCUMENT f ) ..2. '.4;it 7 s e er- r-mqk elet.. Q in io ' 2. elec. volpr. 1 -seiI S t: _d th 1.12'4-1 Dri vie way /plc/Hi-I:O./6M rcrC .7 be ded ony w ))le col veur et.natilly pco m.05 rsve way slope 3__ hne 'ra 7'/0u fro n-I Ho e a ton A- Jen b e ci in sot / tea, ,?/ dole; oe he ) „cc (x le ;6. '1 / // p-4/r1, 3 c r te <A ) exr_otin, 9rade Fr relocotefel to be SrrotrOi c.,l1 Vt.1 - 1 511; fr vrr a sr tlu, / 1-o l ro_kt o _ _ -_ eisetitt - - +P 1.1! -w {rom jolt ( fk.'1sOh rench — ------ i2 3 6-- -- arrer -_ - 1 r - vX - .. /.S!.. t Propa$ec.Q Ft-.€ G vad 1 -1ocs5 r Qrry -t way wil 6c Cut and 6 444 u on /out.) YIO mute rla neecL'S f be relocated ,excrpI Io s• // 1- clvo' - Ire - Plc/1 °'f 1-1TITI I l ITIlpi f. I I I I I I fir rI l Irfn v i 1 F 1 1 I I I I. 11 I I I I IrT1111 I I I ITh I I (I I ITI r 1 h'ITI I I ITITIT I I fh'IT I'I LI 1 f T I f l I I 1 TN 'NON 'L ' 3 4 5 I 6 7 8 ai _ ® FLEXIBLE RULER -302 AWS.�in - .M:— ,I - DOE 6Z BE Lz 9Z BZ CZ ZZ IZ 0z 61 Ell Ll 91 91 4I CI Zl U 01. 1 11 1 111111111111111 1 111 11I 11 11 111111 1 11 1 11 1 11 1 111 11111 1 11 1 1 111U1IIJ11 11 11I 1111. 1111111111111111111[ 111111111111111IIpI1111I1111111114p11111101111111I111, 111111111p111111111 f- r 6 /r %c ,/ c✓ NoaSE IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMENT • Elev Acr++lth ce wi}i. 4a ir� P e 6 75 cr<w-Irw Ge'eW r 11 51 IISSS d. AL..14 cnta //.04 t / /It e / ua 'froh F° o N 1 � Q1 m 8 Q N I Uin < — Q (D 3 o w J w 1- 1- I•- Q w (n ( Z z Z 0(.3 w w O 1 Q 0 w Q 1- � 0 (n Q Wm w 0 � w co W V Cr N � q U q r Q s — . -- _ 6 �� + __ — 1 �- 1- - 6ft.'._ ... ___ -,-- " ir- --��8� Sewer trouem eri7 4 i ._.:._... - -- a� c.T B _ _ / . • ` --. -91620 _. / ._:.::_.- .. _. -. -- � Lor p.sar�! i& Jer_e'Ie+e rs A... •,' �o��. / . ±..— f sics/ —16 1 1 - ,�•� rr 5 s .�,' • .. r . r_ v ii: S: ' ;• 1 . ,. j :1, uu fTl _fl I„mt ranf4ij peprince/ nawo here _13s a rsml - iD . -.._ .lairs dsq-- /�° - -- ol�..n'Ltb._ of- Lao- -- — . i.. `t6ii tetra --- - -- ': _n :.0 ,sms tzr .lines l e ,be_/ ' p.0 se rr M 3o J.. !_8 min toyer J.s- _1 Omar 1 I n main J N •t L I 3 hi 1 `Ur 1 1 1 t�CN s / 1A/af 1 Urwie r5rounti powr•.- flew ra./e.nertl +o n a*(-h exLSf in ,-e-4 l�L-se Q, r.ep aru ov) t , 1 /n ewy '}h ir�cnev5 �:. ^.:: iii: /_::a:'Lr. rte. isc:: s�., ^.n:.�.._�SU" ^ < -._�.. .. 4l 1 f},optr Tay Aceounl 4* / 3Q. E, emff,.'T 310' . _ -: o� "• Parcel'C: Lots 14 and .15, 'Rioek 2, second Addition to Adams' Home Tracts, according to p I' •recorded in Volume 12 of plats, 90,. in Sing County, Washington; APT the youth 2 thereof and EXCEPT the Meet 111.40' of said tot•15i, =STEN WITH an easement for sewer .- the east 10' of the west 121.4O'•of the south lib, of .said Lot 15; SUBJECT TO AND TOTE • 1 an easement for ingress, ,egress tad utilities over the east 30' or said Lot 14. •41 ooys.o�. - /) /so -oe , Sew..�e to be puMpea uc r i s•c approx r2 w LEGAL OESCRIPTIOIS Before the 'hurt sub81v1ston: ' Lots 14 and 15, Block 2, second Addition to Adams' Boas Tracts,• according to'the.plat the • • recorded in Volume 12 of Plats, page 90, in Ping Camty, Washington; EXCEPT -the wait 111.4 feet of,said yot 15; SUBJECT TO An easement for ingress, egress and Utilities Over.the west 30 ' thereof. .. s After t e short subdivision: . Parcel A: Te s� � of Lots 14 and 15, Block 2, 6ecend Addition 'to Adams' Horne Trac ' according to plat recorded in Volume 12 of Plats, page,90,"in King County,.Washington; EXCEPT the west 111.40' of said Lot 15;'BUBJKCT TO and easement for ingress, egress and aver the east 30' 'thereof ;and SUBJECT 10 end••aasement •$or sewer over ,Lbe'west.3D' . bereo Parcel B: The north .. 6.4" of the south 2k 4 of 'Lots 14 and 15, Block 2, Becorid Addition to Home Tracts, according to plat'recorded in Volume 12 of•Plats, page 90, in King County, EXCEPT'the west 111.40'. of said Lot 15; SUBJECT TO Alien TOTKTH6R WITH an easement for i D 'egress and utilities over the east 30' of the south244'' of .said Lot 14; SUBJECT•TO AND TOTETHER WITH an easement for sewer over the east 10' of the west 121.40' A south '246" of said Lot 15. Parcel C: (see above) I [1'i1T�T�rl�ijiil�r� ' 1' iiTIT1Fr�irri'i`�i�ijiil�ii�j�j uns.usus -1• -- • 2 3 4 v,•_ sti,.r =d ci c.cres. .At j-hir f ;me tI ev o I _ �••-- �pQ_ Lnns._cu_cr� a _eleue' oo _drive _ _. rT Propase4 ffousc ,-- 1nfl.Itrwf/on s.ysfrn7 .aye ___Beta/ it ii �iil•i11In1r 5 6 Stale . � 32 L/ m / / P rops) Drrye�ay f-nr- Lets a t _C- _.u, Pu ue C. s41r.7fslte _ .cx +qq�I J ._min . lo from .s s lna,ht/imne4 �f dreitcway_._7`o._.bc ow►ler5 •resporlsibill FLEXIBLE RULER- 302AWe.r,w.. s'il'l 1IIIi 7 8 `l `06 6z eQ LZ 9Z 9Z 4Z CZ ZZ IZ of 6I 6I LI 9I sI VI CI ZI 11 OL ��: �IlIllOil�111111. 1. 1 Illllll�l• III�pl��llll�IIII�IIIIjII�l�II ,IIIIIIIU 1J),I�Illl�lll sill// �lJJ, ��III���JI�IIII�Ip��lll( �Il1�, liil�IlUl11), I��II��AJ���� ,I�U,I,I�II,I�II�I��U,��Illl��l ities os' hingtot e the . k b . S ' / �° /4n N \ 3 IF THIS MICROFILMED DOCUMENT IS LESS� CLEAR THAN THIS NOTICE, IT IS DUE TOj' THE QUALITY OF THE ORIGINAL DOCUMENT '' A -1 I 1 I 1 l /ot sfope C /f'�r p /wr: / sri �n`r /= /Wr Fnundahem t / t f 7�/ooy' 7 cstei ► E/eua�%ofi J �/ J d* dew 2. F/ Oor 4- Roof zero mina 4 , 4..1t l �Orop0$e �i-turway C4 AppR LD — LETTZR DATPp R PUaCI RECEIVEC APR2 21991 TUKWILA PUBLIC WORKS W oR i E2O W ° L Q) f Ill/ Q U� 3 Q (D ILO F z Zz 08 W WQ W I U)o WW I m W I-- 2 ° 1— W aC W i, W H i �a G- m 0) W W U F W Y a Q � W 0 r ■ s. 18-oPA SY- RECEIVED APR 2 2 1991 1 ul\ MLA PUBLIC WORKS 1,31;hty maw " flow from Arre Tin ..../vIirt 3 L " be buy .6n.3A r.dr. ...Tr:L:1h Alpert c e -cieLetod_ay_ ;niali_kt\t/ dr) 7`re•r)c 11 er Arty . fiv, ry ,; n _ao"! b oracle 44 Wd ‘'t _cieste_ootis / or.po3e...1 clrout oy .5 infoitruf/61 1 pce,, 0) 1110 6 7 8 FLEXIBLE RULER •- 302 AWalmw.)01 1,1 10E b BL Z2 9Z SZ CZ ZZ LZ OE 61 Ell LI 91 SI VI CI ZI II 01. ownspocd 1' h ti V; V SC , 5 A/C. . o roole 4 /a." s‘si 3 fteki r • 4-44 ■ 4 4.4.44. ."".•••••-", •• ' t • ' "•• • •••• IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMENT t •1 . 5 or ly/H.J 4. 5 Jot ciepth /o reJts.;c•tur /oyers 2 1 1 " Sod 3 ye fdtioty" 4.10th 2 " ' to sewer maA elcu qjn /o check vc.thit l■ 0 • • c ) ;) 0 to ( o 6 (./ o 0 O 00 b 0 2 p//' . 9 /o by deep scale fa / . 2. „ 1.1 or Do 2. 0 0 C., L 6 0 0 0 • 1 c /0 drive way c c ( e s hipe a 6 r c sod c/eth 943 olhoon 5 re. UC //?C 9r vv.\ 14°43r 3 :- / -kb Lc; n tonic imbecie d firmly in sot 1 174,,,, clala attached) Sec. ic ” / cxu t-in, 9ro cle " ecr 1 17e-we way In fil - ty0,176e1 .1-revic• ( 7 1 0 be , n$ it. dd e /f ony waiter pr.b/ens.s ore crrotecA 6 0. rr r eto 3‘ 14 be se 1.44 j tt rpss . . _ — - - — - - T • • • - • • ylore / fo I .._... • • • • ... • — —...... •t• T'" (Ai et- ruil0 .a. t E, .• r elbee% • " • feern t1•4•ii0h l'n4‘1 . Trot- - -•• - • a p rex - - / 6s i ° C? 6 e ; ktot. Ay-f wi II b eat Qnd /et., no „n...1-c r I nerCh re I 0 Get ec-i 9xtirpl -top 6:1 / d ram french Pv-opoleJ adc p 111 TH1111401 3 4 5 6 7 111 •••••;4-i- • It FLEXIBLE RULER-302 Awxwa • . OE 6 Z Be LZ 9Z SZ 4Z CZ ZZ 1Z QZ 61 81 LI 91 SI VI CI Zt II t.11•• 1 . 1111111111111111111111111111111 0 1111 11 111111 1 1 11 11 11111111111,IIIIIIIIIIIIIIIII!IIIIIIIIIIIIIIIIIIIII! 6 1116 6 110 4 4 4 16 6 044 6 1 6 40 4 r; . • " / , r _ rc 4 , / / L' G HousE / (1' , IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, IT IS DUE TO t THE QUALITY OF TFIE ORIGINAL DOCUMENT E/rui'0 t arilnwr.L. Opab;,, 4 civetett c(4-4,...c.e L'a E>ste. , , ',Ha is, 414 fle,CEV ED APR 1 6 1991 'TUKWILA _ S PUBLIC WOBIC rn UJ ucU Flij u 8 Ww H z 0 8 rc W 2 Lij 1 < 1- rn — 0 UJ Lll cr bid 2 I 2 U./ CC “.1 te) r • x3 1 1 1' L' r ' " . SEATTLE TA90(11A lNTLRNATI NAf. AIR PORT \ I l � � . Isu ucl 1 INOM l t,l L L I -� -- C' 0 U j� y cMICKE ) 27 sr HEIGHT5 \ m eK1,111n5 water 1 �I main new water /,nt to be / %r" Puc sc% -du /rI 3 0 r /8" miet rover 6/o"- 7 n i s b oracle V • Z L 3 u Ater 1 Un s to be purnpec. k vertical rtst clp prox 12 g1Gy .2 r Prop e✓fy Tr Atcourrl 00' -24'o - O /SO - 08 e L — powYY Proposed we fer rrrefer t� — /Oa 20 3 E.45. e,vr stir 3/0 __,Sewer e'a�Pment 9-8 20 S. /so " St fxrs'1rn rloksC LOT A 4` h / Parcel C: Lots 14 and 15, Block recorded in Volume 12 of Plats, thereof and EXCEPT the west 111 the east 10' of the went 121.40' an easement for ingress, egress Lor 5 LEGAL DESCRIPTIONS Before the short subdivision: Lots 14 and 15, Block 2, Second Addition to Adams' Home Tracts, according to the plat thereof recorded in Volume 12 of Plats, page 90, in King County, Washington; EXCEPT the west 111.4 feet of said Lot 15; SUBJECT TO an easement for ingress, egress and utilities over the east 30 ' thereof. After the short subdivision: Parcel A: The TORE :182" of Lots 14 and 15, Block 2, Second Addition to Adams' Home Tracts, according to plat recorded in Volume 12 of Plats, page 90, in King County, Washington; EXCEPT the west 111.40' of said Lot 15; SUBJECT TO and easement for ingress, egress and utilities over the east 30' thereof and SUBJECT TO and easement for sewer over the west 10' thereof. Parcel B: The north '644 of the south 246 of Lots 14 and 15, Block 2, Second Addition to Adams' Home Tracts, according to plat recorded in Volume 12 of Plats, page 90, in King County, Washingtor. EXCEPT the west 111.40' of said Lot 15; SUBJECT TO AND TOGETHER WITH an easement for ingress, egress and utilities over the east 30' of the south 246'' of said Lot 14; SUBJECT TO AND TOGETHER WITH an easement for sewer over the east 10' of the west 121.40' of the south 246" of said Lot 15. Parcel C: (see above) 0 N / 2, Second Addition to Adams' Home Tracts, according to plat page 90, in King County, Washington; EXCEPT the south 246' .40' of said Lot 15; TOGETHER WITH an easement for sewer over of the south 246; said Lot 15; SUBJECT TO AND TOGETHER WITH and utilities over the east 30' of said Lot 14. 4 /c ' ,Y{ ,.o SI1Nrrct otccesS AT t'111J I' 'MC' _ .1...� Propose r4 /10k C /0 rnr 5Et 3 As ASuT / PER LOT /n fl l tr -/ on dry -30' pro p osra Ont.) eway / = LotS 8 C u, O vc v 1 5ar ate exi'Tndln3 rr11n /0 6Orr, /50 $t f'opo /ants eucry e /euatron ciroe MUST se IoM e. Av �5 G IT' Z01,11M( c be - K s see r l e +a I I SGa le .731 " _ / /tc /%tr/ i1TI ITlj'111 1 1 II jiTij ijl "1i ITi'�IIIIIt I�'I'hlf flTlfl;i: 11111,11 ij11 • 1 I�� I I I I I f I p "TH "INCH • 1 2 3 4 5 6 7 FLEXIBLE RULER -302 AW.uu. :OE 6Z e6 LZ 9z SZ 7Z eZ ZZ lZ Oz 61 91 Ll 91 SI 71 CI al U e4 IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMENT r nrzic R .4 -a, /FnundcJ / sf o/ E/ ,air P-/oor i o o l -7W IYr, Pte 7 3 SEPAR PERMIT AND APPROVAL REQUIRED 1) A 1 r SL INe l cc; 0/.6 REQu(RE q� �$APC O R . REgOVE ■►i.Ybow p L C, 12DLI 01 L1./6r K5 Ipw4r15 Pare Sl:PA F * 4 6 " • /ot s /opc k044 . ic4 L Met N.4NIC l SUbjt t to +e. O MiterovAie clivivnika 1 1 ItAgti 1 0roposeel �rtvrwa cc C1 \V S I R 0 I ‘"- 1 kvv ,, X991 t'1P v6i D DOI O FILE COPY 1 understand that the Plan Check approvals are subject to errors and omrssrons and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con. Iractor's coopy of approved plans acknnowledged. By Permit No. W ✓I,L.J Date RECEIVED CITY OF TUKW IIA DEC 17 1990 PERMIT CENTER WU Q I 0. U ( 00 E2 Q H U) z z 08 F- WQ W z LL W ° 11 W W I m w o W U 0: W W ,■ V ~ ) x U = Wre N N CD 713 1- U) W 0 rr 8 2' 4 Ek r or' GOA //3 Zk 6 2 Or) tenfc /? - 19 /nsa /o floa I nTer/ o r• (_)p //5 Z k't .2.' on center /6 IR Al /'t 7' /o" 4P /2 scale 79/ /9 — b 40 ' r u// baihruems f'o have 80 C FP1 f cn/r4 to ex. • 13edroom wlnr�nws proul4Y a cica o/o e n l'n cJ. or 3 o K 3 0 a� / CASe / II havr 2n he' I a /echic 2 11r1�1'i'� • il 5 1f1�111 'I�IfI'�'I 1 P II TN/ INCH FLEXIBLE RULER -302 AW°, 06 60 Be LZ 9Z 5Z 7Z CZ ZZ 1Z O? 61 Ell LI 91 GI 7I CI ZI II 01.: luidiiii�niihui�uuluii unluii�uuluii�unliui�uilluu�uiduu�uiiliiii�uiihiul iiuhm�iuihui�iiiiluu�uuluu�uujiui ilululi�luiluu�unhlu�iluhui�uiihuil�i • 8. /I - / 0 " /2 N 3 ° / cRr uen'/cr.) 1- ex/r r, or VlucMry W■IIrr 4 .I ryee O /'las1e .30.01 n, l; " ftpy2s v.Dc. Izos ' 0 SmolQc d e /ecto J 0 cd roo 3 °y° IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, IT IS DUE TO THE QUALITY OF TIME ORIGINAL DOCUMENT 5 ° 6 T S ' " �I DA/ S ° 6 8 8 u1(IC access x 3o 8Pd roory, 3 ° 9 ° O' 0, 3 n 7 0 ' / i /8 Roof Old cr(x.n5 Tip , g SA. 1 1 CITY OFTIl1KWILA DEC 1 7 '199U PERMIT CENTER W O° N _ ..T. m Q um Q 8 <, u_o ow J w I— Q I- W U) u) Z 06 W 1-.W o J Q 0 W Q 2 ,- 0 VJ O Q W m w mry L"J W - V t. W , A It � � Pi 4o , /1 -81/2 -� 2z / r I _ J / 2 ` r 1- Foan Cla)lon P han 8 w q //S 11 J L___ N\IN. >ci P OI 8 / 416 foof7n_95 /.2 " 4t- /o / I/ 8 3 - - 1 8 q �o ut ' ll'1IS /I- 4-c4 dC r I —I ~ I L C 30 3' /0X Be = \ N o157u1`IScv, Y�inlslleci 9rc1dc G(:oC.NU c�u.. /2 µ 2o ' I8 � c r 1oN coe Scq /C =Qr� FLEXIBLE RULER • 302 AM.,. UiS -. ?` 1-.'n of 06 6z Be az ez sz az CZ zz Iz 0Z 61 el LI 91 sI vl el et 11 pi. . IIIII1IIIIII111111IIIIIIIIIIIIIIIII1IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII1IIIII11111IIIII111111IIIIIIIII1111IIIIIIIIIIII111111III1111IIIII1IIIIIIIIIIIIIIIIIIII11 all deck- piers Yo be .24424 - x /o' w slni pson P 1 rr anchors IC ['. KTe.Np Re LC) \N„) LING = ( '2 ")ORA: 2io16. 5 6ratnijc ' \\ for ,Ardis I ZX!lS.._ haLtra ..ts+ 6oi±am. °i`_ooists . sid43_ of house 4.`16 Q . clash An.c.,+tcol s•Icps to y r•de restle9 on 9 Concrete 1,:)Ncl z s r, ,,.. ,r• r I 1111)111�I11I11111.11111 I h1r�1 111111111g1111111 ,1'1111 " �fjri 111II'1 ,T `` ll 11 r�11rillIIr1r Tji� i " 11 �i 11 1IrIi 11illll1 p isms INCH • 2 3 4 5 6 7 N / / / / / / 4 X`} t eci o s fs 4x9 t /cotes/ past - -n 4 x z� 0 r(! ci IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMENT Y k`f freate. post ix e1 - — E I z- 2X I�.s UP access 1 Q ere.w4 Naf TM� tank 1 1-X8 w 2x6 ae�k joists ., oc, &Se mend R 3 - Zkl1S 0 Garage ax' ._ 4-1 --� 3 ° 6 8 a o rn.n door -�� w1 c /os'- r 2. /avers Type h Gw/3 on all wal /S i ceI /Ins /n Garo9r O f /por f'ru H p/U 3 - .2x 127 nqi /ccl 7'cge7/7er 3 - /6 /D 'C '/ oC C11'/ n1- 111041LP DEC 1 7 199u PERMIT CENTER ' F-8 N � CU H 01 4 N U ((9 Q H Q oO J W I— I— Q F w (O (i) Z 06 bi HW z 1< o c o W Q 2 rn 0 v J O w Q Wm w I o F ('7 t7 ,- W w W 1 H 2 C.6 04 4 - , oc Grow/ 9pgce venfS spaced even I J GrouNd bu „ /So Se ft acre{ 5o0 E /euq'ion u enfe4 bircl blocks eaCh $ . SCq /c 4/' / ' .ITiNTIT7T�ril�,i IiiilppiiiwirrI riilhiillirirui 1i7(Hi �: -=--. ;��� I I I � I 1 I ili � I t I � II ��1� i �1 i1I �� LLL lIII I LLiI L ��. It .LII,I,�I�IL�:(,'TIT! , i - II) 1 2 3 4 5 6 7 84 IF THIS MICROFILMED DOCUMENT IS LESS ..,.� CLEAR THAN THIS NOTICE, IT IS DUE TO =eFLexieLe RULER - sosnw ". "._ THE QUALITY OF THE ORIGINAL DOCUMENT OE 6z se 6z 9z sz 7Z se ze lz 0Z 61 el Ll 91 GI hl Cl zI 11 1111111 II IIIII .liiuliiu uidiui imliin nnliui uulnu, uuluii iulluu uiiliiii uiihui �inliililuuluii 111111111 uiduu uuliui uuhui imliiu uuluii unluu uiduu uiiliiul�� �/- la en fed bira 6 /oc /cs cont,nuouJ lM. wr ll�eT UC3c, 7;2_ (c) /J/o E/eerel 1 Fin F /oo.- L ines RECEIVED CITY OFTl1KWIlA DEC 1 7 19911 PERMITCENTER O W u Q m z� U cc m uO O N F in Z 06 W Q _ I W u_ fn 0 CC W W I m W I a W 6.1 CC W N = M r4 a a m 5 ui rr EN s r E ce v Art i oN /OkvfYl oab /c u cnf cuch w a10 0" / chimney ht 2' c bone /' Ayr-mental 06 net 10 see/e) ven }ca bird blocks cuch slay JGQIc 7 # __ , I .ITFRINIIIP TIIIII11 IiI iTiITh (11MT 'lj'�II`'1''I71 1 71711 I41111a .. p U TNIIINCH 1 • 2 3 4 5 6 7 FLEXIBLE RULER - 302 0c 6Z B6 LZ 9Z GZ 7Z CZ ZZ lZ OZ 61 Ell LI 91 GI 71 CI ZI U CI: . Iuiihiuliuiliniluullliiliudluiluuliiglluililnluuliiulliiiluiililulilnlnuluiiliiuluillililluuluilluulludiui uuliuiliiiduuluiiluillluiliuiluuliuiluiihuilu .IF THIS MICROFILMED DOCUMENT IS LESS ,CLEAR THAN THIS NOTICE, IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMENT 0 N US l \ 11 \ �a1Uev�G r n i \. cuch w . 3 o a" InI1/1rc F /00 line) WEST ELEvATION J RECEIVE C ov M WIIA lko; , yu PERMIT CENTER W u° N I- E N Q) Q Li u) Q 8 Q� 0a, J W ,- D Q W • W Z O U w W 0 WQ In 0 W Q H 2 u 1 O (f) JJ w < Wm W IW 0 E- 2 co 1 W V CC W 1... v, � aaV M Q riiss by °tiler's T I 3 - 3 con?' aluminum ,sc c4k " / 6 1 4 i Ys" 7 - /// scchn, o n .2... X 6 -1. ' 0 C s h■ el R -/ 9 /ns - :/.3 " de t.dailoi) r ii • •, E ul FirrirrriirrrrrnifilTrnirorrolip,. p -r • 2 3 4 5 6 7 tEt: FLEXIBLE RULER -302 AW oc 6Z BG 12 9Z SZ he CZ eZ le 0? 6l 8l LI 91 SI VI CI ZI 11 01 . hy—afitcP At oc 5/ cD4 p/ wood t COM") roe 7 / a. x a /4" oc 4,0 TE 6 p(9 , Adoo t 9p 6 bloclnn5 on o // bcal-,n3 I/6 rin4c.isill hated cuory " hat-5 .4// Door window Ne.ders 6 ,n,1 / poly L/c...por /rr x D r. • / 8 ,t n1in IF THIS MICROFILMED DOCUMENT IS LESS CLEAR THAN THIS NOTICE, IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMENT 1 A. 40 ' 6" 7C-om cud.) cowncr- - 4 - )301+ Mt*. imm caucs.zie ,Jo 113 ICC y ec 7 / " 4- re bay-- RECEIVED P .1•11•11111 1.6.1 CC uj ce)=