Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit 6587 - Johnstone Supply - Walls
b J6H N3T3NJ SuPPLy 0S'37 L • - • rr, - Segale Business Park • 575 -3200 ADDRESS 18010 Southcenter Parkway, Tukwila, WA Z1P 98188 CONTRACTOR Segale Business Park PHONE 575 -3200 ADDRESS 18010 Southcenter Parkway, Tukwila, WA ZIP 98188 NA. ST. CONTRACTOR'S LICENSE # SEGALBP151M5 EXP DATE 7 - 09 - 91 ARCHITECT Lance Mueller & Associates PHONE 325 -2553 ADDRESS 130 Lakeside, Seattle, WA Z1P 98122 • ` • • .: I II - II • ` year 19 SETB ACKS: N - S - E- W - :IRE PROTECTION: Sprinklers 0 Detectors 0 N/A UTILITY PERMITS REQUIRED? O Yes [xQ No Public ■Works) f.ONING: :ONDITIONS (other than those noted on or attached to permit/plans) BAR/LAND USE CONDITIONS? 0 Yes 0 No Ii .I /I • PROVED FOR BUILDING SSUANCE BY: OFFICIA {I / /� i' /) DATE: _. /5-- t / DESCRIPTION BUILDING. PERMIT: FEE:: PLAN CHECK BUILDING SURCHARGE ':FEES AMOUNT::. >189r00: 123.00 :: 316.50 : DATE::> :ITY OF TUKWILA )ept. of Community Development- Building Division 300 Southcenter Boulevard, Tukwila WA 98188 ?06) 431 -3670 3UILDING ,C5 6 ERMIT NO. ( , )ATE ISSUED: 5 I SITE ADD'ESS 18205 'RCM ECTNAME/TENANT Johns TYPE OF U New Building U WORK: 0 Rack Storage 0 )ESCRIBE WORK TO BE DONE: '.00R 'OTAL SIGNATURE: 7 - v ) - V22,- P RINT NAME: - c evt iVc.(Scv 7.ERTIFICATE OF DCCUPANCY NO. - -- BUILDII'3 PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) PLAN CHECK NO.: 91 - 171 BPA Andover Pk W SUIT # VAL E 0 CONSTRUCT ON • $ 18, 450.00 tone Supply ASSESSOR ACCOUNT # 352304 -9119 Addition Tenant Improvement (commercial) U Demolition (building) U Grading/Fill Reroof 0 Remodel (residential) 0 Other: Install new demising wall and add wall behind counter. SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCC.LOAD I hereby certify that I have read and a amined this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. DATE: 6 ( P COMPANY: DATE ISSUED: l This permit shall become null and void If the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT NO. CONTACTED L -�` )Y \Q a. DATE READY DATE NOTIFIED .- B • "� 1 (init.) --gB PERMIT EXPIRES 2nd NOTIFICATION BY: (Init.) AMOUNT OWING 3RD NOTIFICATION BY: (Init.) PROJECT NAME PLAN CHECK NUMBER C W -P IN TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) Etfi({ SQUARE OCC. SQUARE OCC. SQUARE OCC. SQUARE OCC. FEET LOAD FEET LOAD FEET LOAD FEET LOAD SQUARE OCC. TOTAL FEET LOAD _ SQUARE FEET DEPARTMENTAL REVIEW "X" In box Indicates which departments need to review the project. < i . 'PARTMEN INIT: Detectors ■ N/A 14 BUILDING - 5 _ - to initial review tt FIRE O PLANNING O PUBLIC WORKS O OTHER N/A N/A REVIEW COMPLETED INIT: INIT: INIT: UIREME CONSULTANT: Date Sent - Date Approved - ROUTED C vlu I /g/ INIT: BUILDING HERMIT APPLICATION TRACKING FIRE PROTECTION: FIRE DEPT. LETTER DATED: ZONING: REFERENCE FILE NOS.: MINIMUM SETBACKS: N- UTILITY PERMITS REQUIRED? PUBLIC WORKS LETTER DATED: 7/ TYPE OF CONS UCTION: rinklers /W' / 5- (�Yes � o TOTAL OCC. LOAD BAR/LAND USE CONDITIONS? MEM E- UBC EDITION (year): !!16 w- Property Owner: Segale Business Park Phone No.: 9 31bb Address: 18010 Southcenter Parkway City /State/Zip Tu 'ii1a, WA Contractor: Segale Business Park Phone No.: 5'75 -3200 lip . , Address: 18010 Southcenter Parkway City /State/Zip Tukwila, WA 98188 WA State Contractor's License No.: SEGALBP151M5 Expiration Date: 7 - 91 MN Architect: Lance Mueller & Associates Phone No.: 3252553 APPLICATION MUST BE FILLED OUT COMPLETELY Address: 130 Lakeside City /State/Zip: Seattle, WA 0 I hereby certify that I have read and examined this application and know the same to be true and correct, and I am authorized under Blanker Permit Agreement No. to apply for and obtain this permit. Signature: � - c,v,,i - �,_ Print Name: StevenR. Nelson Organization: g ale Busi Park Phone No.: 575 -3200 Address: 18010 Southcenter Parkway City /State /Zip: Tukwila, Wa 98188 ic.vw -ry I -vvi v DESCR PTION::.:. :: :::> AMO NT LEM DAT -WWI • Permit Fee ": l� lip . , 1�1Y PLAN REVIEW [�` _ NUMBER: L I( J i J 15 P-P\ Plan h :ck Fee Off . "a0 MN uiiding Surcharge . APPLICATION MUST BE FILLED OUT COMPLETELY 0 111111E: . . TOTAL - EIR Blanket Permit Agreement No.: 90 Site Address: 18205 Andover Park West Value of Construction: $ $18,450.00 Project Name/Tenant: Johnstone Supply Assessor Account No.: 352304 - 9119 Type of Work: 6) Tenant Improvement O Demolition (interior) Q Other: Describe Work to be Done: Instal new demising wall and add wall behind counter. Building Type: Building Use (office, warehouse, etc.): warehouse Nature of Occupancy (printing, manufacturing, etc.): Wholesale sales. Will there be a change in use? 0 No 0 Yes If "Yes ", explain: Square Footage — Entire Building: 96768 Construction Area: 13824 Tenant Space: 20736 Will there be storage or use or flammable, combustible or hazardous materials in the building? 0 No Q Yes If "Yes ", explain: CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard — #100, Tukwila WA 98188 Will there be ANY structural work? ® No Q Yes If "Yes ", describe: BLANKET PERMIT Tenant Improvement Application FEES (for staff use only) See reverse side of application for specific plan submittal requirements and information. [Date application accepted: _, Date application expires: GENERAL INFORMATION' This tenant improvement application may be submitted for non- structural interior construction which is authorized under an existing approved blanket permit agreement. It Is the responsibility of the applicant to be aware and comply with all the terms and conditions as set forth In the agreement. The work is limited to that shown on the plans as submitted with this application, and such work is limited to non- structural interior construction only. The following work is not covered under the blanket permit process and separate approvals, permits and inspections are obtained through the applicable agencies. ELECTRICAL - Department of Labor and Industries (872 -6363) PLUMBING/GAS PIPING - King County Health Department (296 -4732) FIRE PROTECTION - City of Tukwila Fire Department (575 -4404) MECHANICAL - City of Tukwila Permit Center (433 -1851) RACK STORAGE - City of Tukwila Permit Center (433 -1851) BUILDING PERMIT APPLICATION Application Submittal - Application and plans must be complete In order to be accepted for plan review. Make sure to fill out the application completely and follow the plans submittal checklist which follows. Handouts are available at the Permit Center which provide more in -depth detail on preparing the submittal. Authorized Agent - The applicant must be an authorized agent as Identified In the Blanket Permit. Fees - The permit fees are based on valuation of construction as declared by the applicant on the application, and shall Include all the work to be covered under the permit. The valuation will be reviewed and is subject to revision by the Building Official to Insure compliance with current fee schedules. To obtain a fee schedule, contact the Permit Center at 433 -1851. ❑ Completed Building Permit Application ❑ Attachment #1 - Architects Statement SUBMITTAL. HECKLIST ❑ Three (3) sets of construction drawings, which include: ❑ Site Plan, showing: a Building location on property O' Adjoining public right -of- way(s) Parking layout O of tenant space or area of work within building Cl Overall dimensions of building Gr Overall dimensions of tenant space, or area or work . 0' Name of each common wall tenant(s) and type of business or occupancy ❑ Floor plan of entire floor or tenant space that the work is taking place, showing: er space layout with use of each room labeled C$ All exit doors, corridors and egress patterns Cr All new walls, existing walls and proposed walls (provide construction key) 0" All other proposed construction ❑ Construction details 0' Construction key O' Cross sections showing wall construction and method of attachment, floor and ceiling Cr Reflected ceiling plan (if applicable) ❑ Miscellaneous O 6" x 8" blank space provided on lower right hand corner of each page of plans (for use by the plan checker) O Title block on each sheet, identifying: • Project name • Company job number (if applicable) • Site address • Blanket permit agreement number • Architect, address and phone number O Each sheet of plans stamped by a Washington State licensed architect O Minimum sheet size 18" x 24" O Plans must be drawn to scale and clearly dimensioned Drawings shalt be prints which are clearly readable (original pencil or highlighted drawings are not acceptable.) ❑ Permit Fees (plan check fee, building permit fee and state building surcharge) Is any part of the work proposed under this application include structural work or affect structural components of the building? 0 Yes 0 No PROJECT NAME /TENANT: Johnstone Supply COMPANY JOB NO.: 91- 731 -02 if yes, has the structural work been authorized by the Tukwila Building Official to be Included in this application? 0 Yes 0 No Does the proposed work comply with the requirements of Chapter 33 of the Uniform Building Code (1988 Edition)? Q Yes 0 No If no, please explain: Will any special inspections be required per Chapter 3 of the Uniform Building Code (1988 Edition)? Yes x No If yes, list specific inspections: •• . -- • • •• ..::i As a result of this proposal, does the parking meet the requirements of Tukwila Zoning Code parking requirements? ©.Yes'. No ` : • :... • • . . If no, please explain deficiency: • ' . : :-- :. • , ` SITE ADDRESS: 18205 Andover Park West PROJECT NAME /TENANT: Johnstone Supply COMPANY JOB NO.: 91- 731 -02 CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 Phone: (206) 431 -3670 ( BLANKET PERMIT AGREEMENT Tenant Improvement Application Attachment 1— Architects Statement PLAN REVIEW NO.: Architect/Engineer Signature: Print Name: Bob Fadden BLANKET PERMIT 9 0- 0 01 AGREEMENT NO.: qi Iii 3FA Firm Name: Lance Mueller & Associates Business Phone: 325-2553 Street Address: 130 Lakeside City /State /Zip: Seattle WA PROJECT: D A fr ' 1 L ► .O_ EN IN II 1111 IIII PERMIT NO. Co . % SITE ADDRESS: I ,, (. , / , DATE CALLED: ..... 1=2" --- Cj I TYPE OF INSPECTION: L . _ _. , DATE WANTED: 7 ► -- - SPECIAL INSTRUCTIONS: REQUESTER: PHONE NO.: 6 '7 -0 C r INSPECTION RESULTS /COMMENTS: INSPECTOR: .. x DATE: 7 " ' CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: , ' >r" • ' '' I J 4,41, A44 PERMIT NO. / 7 � SITE ADDRESS: ; s 05 ,,,,N, ( %r DATE CALLED: , — � TYPE OF INSPECTION: ft/Yl/ DATE WANTED: — / ? �- / / p.r SPECIAL INSTRUCTIONS: U REQUESTER: PHONE NO.: L 75-- 3D-n INSPECTION RESULTS /COMMENTS: & �/ p 3 c•'I�- O ,.�XS.-p `-1-0 C.St- v-c-(' I 1t1 -„r+c G f � .AAs� G c ttMA C 0.04-0 C` , -� . n..,kr-t,. " • :...- j c 0. . Id c l-. 1..1L 't. cock --,. -- -4v c U r A- -a-, -A L. j T <- •Y -..- , --1 Z --- # Z .9 �.� .,-n 1 e a-• n�- 1.�. ..�. t, 1-ic -t i-t -.,1c A.-a a , - .--- t - --- INSPECTOR: -- -- DATE: Co -- ( 7 -�i CSTY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTION RECORD 6300 Southcenter Boulevard - #100 Tukwila Washington 98188 PROJECT: Ow . 4 r--tryi,(-- PERMIT NO. (05 • 7 /I SITE ADDRESS: / K D c) 5 c - A4L( 9 4 - 7A-04 VaiLle u )60 DATE CALLED: Co — / / / ? q —4 7/ 13,111 TYPE OF INSPECTION: DATE WANTED: SPECIAL INSTRUCTIONS: REQUESTER: PHONE NO.: 5 D INSPECTION RESULTS/COMMENTS: - a ii. \C c .A\--v R- C 4- I 74--:1N ' ° DATE: .,.'• 72 INSPECTOR: -(. CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431-3670 INSPECTIad RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: ffiii . ,A 6 1 1 4 I I 4 ....LI ir PERMIT NO. 65 j - SITE ADDRESS: t i./ / , , DATE CALLED: —02 q/ TYPE OF INSPECTION: rta4totl 1 DATE WANTED: a.m. SPECIAL INSTRUCTIONS: REQUESTER: • A PHONE NO.: INSPECTION RESULTS/COMMENTS: E r\ A wt 0/NS C.-- (s E --- (_1/4.•=rt 6-41--try.-- --iNi (-A–us i.N.4.2.4 P it- . Giv•sY /.1/1.-%. L ,..\ GI (s crpd* S-4,./2 4. INSPECTOR: (---5?-- DATE: Z.3 - ctJ CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431-3670 . • INSPECTIO RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: �OhY1 f-7 Su I PERMIT NO. kSD / SITE ADDRESS: )% aO 6 ' 1. • V-e w DATE CALLED: S I Le-- 4 I TYPE OF INSPECTION: ip 1 A � SPECIAL INSTRUCTIONS: IMMIIIIIIIIIIII DATE WANTED: I — ; REQUESTER: ,1i� # \ #. 0 PHONE NO.: 55 aO INSPECTION RESULTS /COMMENTS: . �,, .. m • _ / INSPECTOR: 4'X"- nit DATE: s -17 -9/ CRY OF TUICWIL.A Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTIO14 RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 r . (sow. /.lAt ' ! .. • Authorized Signature City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Needs shift inspection TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name f F °�i) t.t Address / ( \ / 0 ( Retain current inspection schedule Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: _ Hood & Duct: Halon: Monitor: Pre -Fire: Permits: F743 Si Gary L. VanDusen, Mayor Control No. /J 7 / Permit No. ( E: T7 V Suite # 1 Date FINALAPP.FRM 'T.F.D. Form F.P. 85 "X' REQUIRED INSPECTIONS PHONE AP DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 �'i 7 Framing 431 -3670 8 Insulation 431-3670 ,9 Suspended Ceiling 431 -3670 10 Wall Board Fastening 431-3670 . 11 12 13 X 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 x 17 BUILDING FINAL 431-3670 (INSPECTOR COMMENT SECTION ON REVERSE) SITE ADDRESS: 18205 Andover Pk W CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 1:3UILUIIVu h'Cti1V111 INSPECTON RECORD (Post with Building Permit in conspicuous place) SUITE NO.: BUILDING / NO. CQ�J�� DATE ISSUED: a / -- 1 PROJECT: Johnstone Supply CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be Installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. Op/1V CITY OF TUKWILA 6200 SOUT!ICRNTE'R BOULEVARD, TUKWILA, WASHINGTON 98188 Plan Check #91 -171: Johnstone Supply 18205 Andover Pk W PHONE II (206) 433 1800 Cure L. VinI)usrn, Mayor THE PLANS UNDER TUKWILA UKWILA BUILDI G PERMIT NUMBER (00-b. p THE APPROVED 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (277- 7272). 3. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 4. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 5. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 6. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. PLAN REVIEW COMMENTS Plan Check No.: - ' 7 I Project: -- %-4Nr6TOt45. r „�U REQUIRED INSPECTIONS 0 No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277- 7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. 5. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high - strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. 1. Footings 2. Foundation 3. Slab /Slab Insulation 4. Shear Wall Nailing 5. Roof Sheathing Nailing 6. Masonry Chimney X 7. Framing 8. Insulation 9. Suspended Ceiling X 10. Wall Board Fastening 11. 12. 13. X 14. Fire Final 15. Planning Final 16. Public Works Final X 17. Building Final PLAN REVIEW COMMENTS Plan Check No.: - ' 7 I Project: -- %-4Nr6TOt45. r „�U REQUIRED INSPECTIONS 0 No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277- 7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. 5. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high - strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. Fire Department Review Control #91 -171 (512) Dear Sir: City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 May 9, 1991 Re: Johnstone Supply - 18205 Andover Park West Gary L. VanDusen, Mayor The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10 B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) (UFC 10 -1 (3 -1)) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.6), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.6) (UFC 10.301) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher," with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC 10.301) 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 3302(d)) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) There shall be no enclosed usable space under City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 2 Gary L. VanDusen, Mayor stairways in an exit enclosure, nor shall the open space under such stairways be used for any purpose. (UFC 12.106(c)) Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 10.402(a). Exit signs shall be installed at required exit doorways and where otherwise necessary to clearly indicate the direction of egress. Signs shall be of a contrasting color with the surrounding area and shall have letters not less than six inches high with a minimum letter width of 3/4 ". (UBC 3314) (UFC 12.108) Exits shall be illuminated at any time the building is occupied. An emergency system shall automatically provide exit illumination upon failure of the main power supply. (UFC 12.107(a)(b)) 3. All modifications to sprinkler systems shall have the written approval of the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528) (NFPA 13, 1 -9.1) (UFC 10.307) All sprinkler drawings shall be prepared by companies licensed to perform this type of work. Drawings shall first be approved by the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528 & NFPA 13, 1 -9.1) (UFC 10.305) Contact the Tukwila Fire Department, Fire Prevention Bureau to witness all required inspections and tests. (NFPA 13, 1 -10.2) (UFC 10.305(b)) All Alactrical work and eauinment shall conform Page number 3 City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Gary L. VanDusen, Mayor strictly to the standards of the National Electrical Code. (NEC 70) (UFC 85.101) All electrical wiring is to be inspected by the State Electrical Inspector, Washington State Department of Labor & Industries. (NEC 70) 5. All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly,. >gS /2 The Tukwila Fire Prevention Bureau cc: T.F.D. fiel ncd CITY OF TUKWILA Department of Community Development - Building Division Phone: (206) 431 -3670 PROJECT: G, J4, 0 ADDRESS: 7 ' t7! Wu ao-u-ex. O- L . c-0 DATE: OCCUPANCY GROUP - TS =Z. TYPE OF CONSTRUCTION LOCATION ON PROPERTY BUILDING HEIGHT /# OF STORIES FLOOR AREA (3 OCCUPANT LOAD 1-1 G EXITING REQUIREMENTS PLAN REVIEW PLAN CHECK NUMBER 91- 171 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 S ai DETAILED REQUIREMENTS OCCUPANCY TYPE OF CONSTRUCTION PART V, CHAPTER 23, U.B.C, W.S.E.C. CHAPTER 51-10, W.A.C. NOTES PREPARED BY: DATE: (nave plan Keview numoer, tiianKer permit Agreement numoer, project name and site address ready) "X" REQUIRED INSPECTIONS DATE APPROVED INSPECT iNmALS PLANS DATE DATS CORRECTION N ISSUED 1. Framing 2. Insulation 3. Suspended Ceiling X( 4. Wallboard Fastening DO NOT PROCEED BEYOND THIS INT UNTIL THE BUILDING PER PERMIT MUST BE PICKED UP WiTHIN 24 HOURS OF NOTIFICATION THAT THE diT IS ISSUED. PERMIT IS READY. CITY OF TUKWILA Dept. of Community Development - Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 BLANKET PERP AGREEMEN1 Tenant Improvement Temporary Inspection Card Plan Review No. Date Issued: Blanket Permit Agreement No.: ciO-DO 1 Project Name /Job No.: Site Address: I`G QOJ Nrlrlc \ -er PK 11J 5 1 ,►• Suite No.: CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (431 -3670) INSPECTIONS 1. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 2. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilatior points clear. 3. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 4. WALLBOARD FASTENING - Prior to taping (See UBC Chap. 47 and Table 47G). 5. PLAN CHECK INSPECTION - immediately after the Tenant improvement Permit is picked -up by the applicant.Work may n proceed until the City Inspector delivers the plans and new Inspection card to the site. This inspection should be scheduled at the Permit Center when the permit is obtained. CONTRACTOR /APPLICANT BEGINS WORK AT THEIR OWN RISK PER THE TERMS OF THE BLANKET PERMIT AGREEMENT. • Construction will not proceed past required inspections. • The Building Permit and approved plans shall be picked -up by the applicant within 24 hours of notification that the permit is ready. Failure to do so may result in a stop work order. • Construction may not deviate from that shown on the plans as submitted at time of application. • All corrections shall be undertaken within three (3) days of notification by Building Inspector, unless otherwise agreed to by both parties. • No more than 30 days shall elapse between tho last required inspection and the "Building Final." • Unauthorized occupancy and/or use of the remodeled area shall not occur until the Building Inspector completes the "Building Final," which takes place after the Building Permit and Permanent Inspection Card has been issued. • The City reserves the right to stop work at any time that in its judgment the work presents a safety problem, warrants a building permit prior to continuing work, Is not proceeding according to approved plans, or otherwise would not qualify for consideration under the blanket permit process. • The following work is not covered under the blanket permit process. This work shall not start until approvals and permits are obtained through the applicable agencies, under their normal process: Electrical — Department of Labor and Industries (872 -6363) Mechanical — City of Tukwila Permit Center (431 -3670) Plumbing /Gas Piping — King County Health Dept (296 -4732) Rack Storage — City of Tukwila Permit Center (431 -367 Fire Protection — City of Tukwila Fire Department (575 -4404) If special inspections are required, work shall not proceed past where special inspection is required, or special inspections must be pre- arranged with Building Official. THIS IS A TEMPORARY INSPECTION CARD ONLY AND WILL BE REPLACED BY A PERMANENT INSPECTION CARD WHEN THE BUILDING PERMIT IS ISSUED. FOUND LEAD 8 TACK IN WALK PIT • I r•: I ." . FOUND , CONC.MON. .' • ; SET, BRASS CAP IN ASPHALT Water Valve ,TAt.K IN RR. TIC I FOUND, CONC. MON. Elec. Outlet Box N 30 *55'/5 "W 52.59 --- - -- , Sprinkler Heads a 4 y a e SAN. M.H. Catch Basin • " 47 i tru • P LANTER • • dCnI C R r _ r E 0 R A'S Sprinkler Heads"' ~_ d = 05° 22 20" 1 1 _ Railroad TrQc4Cs -i - -ST -6 "- Gi0'NC. • -- •• .cONC, 0UTTER ' R. 2470.90 1 = 23/.5.9 empol. *AMINO IL - 41.e.1111. N 07 °44'56" E 2/3.72 . M OnsworsammoliER3 annt. If.. AN-D-0-\;440- 1 dromitssaismoir G RAVEL .SI'prink /er Heads CONC. MON., END. 42.11 . R• 47746 TACK 4N R.R. TIE L. 97. 22 - S 07'44`56 --r- _~ __ -____ =- PARK -WEST Roof Drain UMW e SINGLE STORY OFFICE- VVAREHOU (CONCRETE). Transformer Automatic Sprinkler .Valves I U • : nd that the Plan. Check approvals are object to ors and omissions and approval of plans does • uIho tze the violation of any adopted code or ' >'nonce. Receipt of contrector's copy of approved p acknowledged. t H T E R ^ r`APPRdcIMATE• Roof Drains ATLON CXth €R MAf� . ... Electric Meter Gas Meter Ro�f Drain : , � 9 PARKING NOTE Q 3 49 �' SHOWN TACK IN R.R. TIE 9. 97 Set ST. 6 "CONC. °t .9I t r. J 1 ArPO;..cNATE`LOCUM or OAR 'id Mel • ' CONC. &UTTER -. - /9/. 25 Eire- Hydrant SAN. 30.10 Roof Drain •; CONC,RTC I LOAOIry& GOOK • .1 0 �1 MI ;. fTACK IN R.R. TIE i SET, CONC. MON. C.B. e20 cncroachir, 1 t !wipes?' .'r yNr/ 0.7 Encroachment WIDEST POINT) ° % SET & R A S 3 ! LEAD &TACK IN WALK et E! seinent 765:42 S07 ° 44' 56' " W ATT.ACIIIVIENT #1 SBPIM.AS BUILMING 731 Scale`' 1 20' 0 fe tH$ INCH 2 • 1 3Far' Nat ^' -. •� J r ;a oc 6Z 8C LZ 9Z sZ hZ CZ ZZ II CZ 61 81 LI r 1 I 1 �IIIIiiiiII. IIIiiiIIIi1IIIIIIIIIIIIIIIIIIIIII�IIn ffilhiii iI I IIIIIIII.!II II i I I 1 111111 IIIIIIIInI�IIII,IIIIIIIl.�II l:li�ll�.IJ IIII! III' 1 1 1 1 1 11 1 t1'I1IIIIIIIIIII,II I1i1 1 111111 II I, 3 4 5 6 7 NOTE: If the microfilmed document is less clear notice, it is due to the quality of the original 91 cI hl Cl ZI It pi. 6 8 L 9 5 h C Z I wN 11H 1 111I�1111 iIII�IIl1111ii�Ilillllii�ill1I 11I� 11 1�l" "li"„W11 °�,+Il,i,�I�, 1"11,"„1t� th ill i 1 ii Iln ttlinttuccicnc " "! II I ct I!i t I IIf111i1 Illlil IIII Ill► IIl! (II► W11111111 II 111111 I1III111111111 11111111111111111111j1L . ILILi11I . 8 9 10 11 w1DEINGERwhKY 12 than this document. CONC. MON , FNb LEGAL DESCRIPTION: That portion of the Southwest Quarter of the Northeast Quarter of Section 35, Township 23 North, Range 4 East, W.M., in King County, Washington, described as fgllows: BEGINNING at a monument et the Northeast corner of the said South- west Quarter of the Northeast Quarter; thence South 07°44'56" West 765.42 feet; thence North 82°15'04" West 30.00 feet to Point '°A" and the TRUE POINT Or BEGINNING; thence South 07 °44'56" West 191.25 feet to a Point of ; Curve, thence along a curve to the right having a radius of2,470.00 feet thru a central angle 0.5 °22'20" an arc distance of 231.59 feet; thence North 69 p 15 04 West 55.31 feet; thence North 30 °55'15" West 52.59 feet; thece North 82 °15''04" West 187.64 feet; thence North 07°44'56" East 213.72 feet to a Point of Curve; thence along a curve to the right having a radius of 477.465 feet thru a central angle of 11 °40'00" an arc distance of 97.22 feet; thence North 19 °24'56" East 59.97 feet; thence South 82 °15'04" East 263.25 feet to the TRUE POINT OF BEGINNING. SUBJECT TO AND INCLUDING an easement for sidewalk and utilities purposes over the Easterly 15.00 feet thereof. SUBJECT TO AND INCLUDING an easement for railroad purposes, in- eluding but not limited to, main track, lead track and .spur tracks, over that portion thereof lying Westerly of the Westerly building line produced. RESERVING to lessor the right of ingress and egress to maintain, install, improve and extend utilities. TOGETHER WITH A SUBJECT TO an easement for building setback purposes over a 60 foot wide strip of land Surrounding and, ad jacent to the main building line, which is .described as follows: BEGINNING at the said Paint; "A "; thence `North 82 °15'04" West,OO.00 feet; thence South 07 °44'56" West 3:0.00 feet to the TRUE P©I' of BEGINNING; thence continuing Sout;h`07'44'56" West 3 36.00 feet; the "hae North 82°15'04" West 144.00`feet; thence North 07 °44'56", East'336.;00 feet; thence 'South 82 °15'04" West 144.00 feet to the TRUE POINT OF BEGINNING. . C.B... _ ... Fetch Basin M.H... . . . . ... Mon Hole ........:. SAN ... San /t'ory ST Storm ..:.. _ CONC .... Concrete Sanitary Sewer Storm Sewer Water Gas Telephone Electric ,.0 .LEGEND SURVEYORS CERTI FICA a E I hereb y certify this "map correctly represent o survey made by me or under my direction. This 5 Dar of Jul 19 75 REGISTERED LA D SURVEYOR Existing Tree NE COR SW 4, NE % 'C. 35 a T23N -R4E etiweth � achnran SURVEYORS ENGINEERS RECEIVED rrry TI IKWR.A MAY 1 1991 DRAWING N.. 2354 REVISED L.S. 8271 A ►►R R. E. M. r TUBE SITE ADDRESS: 18201 182e1 Andover Park We A. T. A. Survey for M.A,. Se4a a Inc. SEGALE INDUSTRIAL. PARK TUKWILA WASHINGTON , SCALE I "s 20' .- DATE :JULY •'3, 1975 DRAWN IY y1 W. S.