HomeMy WebLinkAboutPermit 6608 - Bon Marche - Storage RacksPermit 6608 - Bon Marche SHE BoJ BP4 (0(o0 ' Racks UBC EDI year 1988 SETBACKS: N- S- E- W- FIRE PROTECTION: Sprinklers Detectors ❑ ❑ N/A UTILITY PERMITS REQUIRED? Yes ❑ ❑ No (through Public Workal ZONING: BAR/LAND USE CONDITIONS? ❑ Yes ❑ No CONDITIONS (other than those noted on or attached to permitplans) CITY OF TUKWILA Dept. of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDING PERMIT NO. DATE ISSUED: PROPERTY OWNER Bon Marche ADDRESS CONTRACTOR ADDRESS WA. ST. CONTRACTOR'S LICENSE # ARCHITECT ADDRESS TOTAL: APPROVED FOR ISSUANCE BY: PROJECT INFORMATION SITE ADDRESS 17000 Southcenter Parkway DESCRIBE WORK.TO.RF DONE: SUITE # PROJECT NAME/TENANT The Bon TYPE OF U New Building U Addition WORK: ® Rack Storage ❑ Reroof Li Tenant Improvement (commercial) U Demolition (building) Li Grading/Fill ❑ Remodel (residential) ❑ Other: Add 1600 Lineal Ft. of 29' High Furniture Storage Rack VALUE OF CONSTRUL HON - $ 125,000 ASSESSOR ACOOUNT #262304- 9077 -0 17000 Southcenter Parkway Same as Above (Owner) COQE COMPLIANCE SQUARE FEET SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD °C C. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCC. LOAD (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) BUILDW PERMIT FEES AMOUNT : RCP.T # 473 28: r{ li)77 477.78 < /: BUILDING:PERMIT FEE DESCRIPTION. :: >� ': PLAN CHECK FEE BUILDING:SURCHARGE TOTALi PLAN CHECK NO.: BUILDING OFFICIAL 91 -207 PHONE 575 -4979 PHONE EXP. DATE PHONE DATE: ZIP 98188 ZIP ZIP I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. SIGNATUR ‘a" PRINT NAME: T 1 2 /i'/ T his permit'shall:become null andvoid if the work is not commenced within 180'days fromthe:date of issuance, or if;the work is suspended or abandoned for, a period of 1 89 days from the last inspection. DATE ISSUED: CERTIFICATE OF OCCUPANCY NO. NIA DATE: - -,/ PERMIT NO. CONTACTED DATE READY ` Q 6-5k-91 DATE NOTIFIED � .-'.� � " BY: (init.) —af3 PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING Li 3RD NOTIFICATION _ BY: (init.) BUILDING +'ERMIT APPLICATION TRACKING PROJECT NAME PLAN CHECK NUMBER SITE ADDRESS r1 000 INSTRUCTIONS TO STAFF Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGEJOCCUPANCV INFORMATION (to be filled out by Plan Checker) s�� f•: s;%�ti: SQUARE — gET OCC. LOAD SQUARE OCC. SQUARE OCC. O D s D i DEPARTMENTAL REVIEW "X" in box Indicates which departments need to review the project. FIRE FIRE PROTECTION: Sprinklers FIRE DEPT. LETTER DATED: 5' -2-i 'J UBC EDITIO (year): BUILDING - initial review O PLANNING O PUBLIC WORKS O OTHER REVIEW COMPLETED ROUTED INIT: INIT: INIT: I ho_ oci\I aLk`IPl0DI'1't✓ f REFERENCE FILE NOS.: BUILDING - 5-31 TYPE OF CONSTRUCTION: inal review 5 (I INIT: UIREME UTILITY PERMITS REQUIRED? PUBLIC WORKS LETTER DATED: Yes (l No SUITE NO. CONSULTANT: Date Sent - Date Approved - Detectors INSPECTOR: 5') ZONING: BAR/LAND USE CONDITIONS? MINIMUM SETBACKS: N- S- E- W- TOTAL OCC IAA CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 APPLICATION MUST BE FILLED OUT COMPLETELY PLAN CHECK () 1 _ r_3_ 0 -7 NUMBER l 1 SITE ADDRESS 17000 Southcenter Parkway, Seattle_, WA 98188 PROJECT NAME/TENANT Bon Marche Racking Add 1600 Lineal Ft. of 29' High Furniture Storage Rack BUILDING USE (office, warehouse, etc.) Warehouse NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? No U Yes IF YES, EXPLAIN: SQUARE FOOTAGE - Building: 500,000 Tenant Space: PROPERTY OWNER Bon Marche ADDRESS CONTRACTOR ADDRESS WA. ST. CONTRACTOR'S LICENSE # ARCHITECT ADDRESS (:HE REBY CER TI( AND CORR BUILDING OWNER OR AUTHORIZED AGENT Distribution 17000 Southcenter Parkway Same as above RIZ SUITE # EXAM. SIGAI� A"(�URE PRINT NA 7)A ,'I-IX') t — ADDRESS/ 700c, /4-4 t/ CONTACT PERSON lvlt.�:R)cc., 5 f ph c BUILDIha PERMIT APPLICATION DESC'F O `: MO BUILDING PERMIT,: FEE PLANCHE TOTAL IZEMINElatin lintiMiattlaMMISEN ENEILIMINIMINEMMI VALUE OF CONSTRUCTION - $ 125,000 ASSESSOR ACCOUNT # TYPE OF U New Building Li Addition U Tenant Improvement (commercial) ❑ Demolition (building) WORK: ® Rack Storage U Reroof ❑ Remodel (residential) 0 Other DESCRIBE WORK TO BE DONE: Area of Construction: 100,000 WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? ® No 0 Yes IF YES, EXPLAIN: PHONE PHONE EXP. DATE PHONE ZIP ZIP 57 --4979 ZIP 98188 DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES DATE PHONE 375 X797 PHONE- 75 5/9 CITY /ZIP _.� APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and Is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations, The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of ttlg Uniform Building Code (current edition). No application shall be extended more than once. '$. If you have any questions about our process or plan submittal requirements, please n �� contact the Department of Community Development Building Division at 431-3670.% t �C ciN RACK STORAGE SUBMITTAL CHECKLIST ••• • . : • Legal description Working drawings, stamped by a Washington State licensed • . architect which include: Site Architectural drawings • Structural drawings • Mechanical drawings • Elevations Civil drawings • Landscape plan fl Completed utility permit application (one for entire preleet) . . : . Six (6) sets of civil drawings • . NOTE: See utility permit application and checklist for specific utility submittal requirements. • . j Completed building permit application::: :::.•••••:, „ •: r --, :• Assessor Account Number : •-• : • •• • . . . Tenant space floor plan showing rociStorege layout, aisles exits. • N OTE:: Include dimensions of racks and exit ways on plan . . . . Structural calculations stamped by a Washington Statelicensectii.:: . engineer (radi storage ancl:over): •••••:••:-. • •• ••• : • : RESIDENTIAL NEW SINGLE-FAMILY OWEI.I..INGS/ADDITIONS . . . .„ . Completed building pennit applicdon (one for each sttua) Legal description .• E:1Atisesser. Account Number . . „ . . • • •• .... • •• • .• . . • • . Two sota.(2)ofwarking drawings *hick ..'',.••••••••••••• ••••. •" •••••••.••• ■.Site Foundation • Floor plan " •••• •••'' :"' • Root plan Building .elevations ............................................... ••••.•••••:•:• :•::' • • • Stalk:ling cross-section: ■.Structural framing plena: • •• • •'" -:" • • • • • ••• • • • .:• • • .. • „.:„.„:•.:..,..... . .„.. . Washington Sta Energy code data • : ••• D Completed utility permit application ••••• Ei•Sla ,.(6):sets of site plans showing. utilIDe . • NOTE Bulking she plan and utility site plan may be eetettineckc'qett:'..::: uwiiy perthlrepplication and checMst ter specitioseprititteiptleiremett#ii Ackitional lOpographiqel and soils information may site Condhions. •• I COMMERCIAL TENANT IMPROVEMENTS ParrnitPPPliPail9n structure or • • •• Two te nant} 1 Number n I rtalidtenan pro posed Ag te ses" plart locatio ..:.... 7 . Qa spa par king ( 2) sets over building plan wail) or sq.iare tenan rootage Existing aiaatinnt;6(ni on ng Use amen t Floor * P T of 61°n of to tan of with itse he demon Exit w.aispflsgre proposed and walls New ceilinofge::::alln 0:8) • *. C1,0171"calCuClailiti:fonrsflo:rif awsililairtil:ingeispatorsba State done a any n: , : be z....i5. to be do NOTE 60 and engineer El Cons tructio n s and Washington (2 se atbIC'h stamped reUrfilT17 . .. , ....... . . . Completed bullcirtg: permit Lppli each atrUcture) Assessor Account Number Narrative .desCribing oxiStIng roOltriatedel being removed, and •• NOTE:: A certification letter Is required prior to inSPectionandsiOn4:::::.: •.: off of the . . . . . . . . iNTEt11 ••: Completed bulkng permit applicetlon AsSeaserAceOunt Numbe r . : . . . • Completed bkilldim permitaOptiCetiOnl(ena for each atrUC tore) Assessor material being Installed. • ••• NOTE A certlficeb;?rt letter Is required psior to final kispocti • Off of the permit. CITY OF TUKWILA 6200 SOVTIICENTER BOULEVARD, TUKWILA, WASHINGTON 98188 MEMORANDUM TO: FROM: � h�, \ �l �, 1 0:1 DATE: f in c)) l g q I SUBJECT: _l__c�c._K 33r 0 ,e. _ C L c,.5 k'r-'3 h Roc TotoJ 5(0 X Dq k (p,L4(o cscc D X ca Ok LP 3aS ÷ too = 1- 4 - 73. DS ¶ota1 7 ) `"7 ^7 S' PHONE # 1206) 433.1800 Gary L. VanDusen, Mayor COMMENTS: • ) a VI La ..... ' .L/ : ciL. - Tv= TS...,Q P(L\Pas�7 Q(a) wt12..c , a - cr i.4 A -Li t hi S" -a C 9 'Flo__ (>4_A-,..). i --,`„A 0 -„,......,2_. 0 3) H p , - —, = N) t vA CO Art- P» imk \ S y --(2.-All i-r- A NJ P nt' 0/ A .,,, _s C , l .s r - pew.._ -i— t le_ -�, Spec onsr Reques�gr; al. - -ao� Phone No,:: Project: ) to M (ftC.F ly SG, ype o nspection: c Pa./ Address: S � C. 21--64 Date Called: —ale-Wanted: -�, Spec onsr Reques�gr; al. - -ao� Phone No,:: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. I Inspector: INSPECTION RECORD ( Retain a copy with permit (206) 431 -3670 0 Corrections required prior to approval. p ale: — q2-- -- 0; $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Lt No.: Date: 1 Authorized Signature FINALAPP.FRM City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Project Name 64 --+ Address c' �.d;� Sprinklers: Fire Alarm: ✓" Hood & Duct: Halon: Monitor: J `1 Pre -Fire: .A, Permits: TUKWILA. FIRE DEPARTMENT FINAL APPROVAL FORM /Retain current inspection schedule Needs shift inspection .Approved without correction notice Approved with correction notice issued Control No. { 1 " Permit No. d u`!� Y'' Suite # Date Gary L. VanDusen, Mayor T.F.D. Form F.P. 85,_, _ ' 1Y 4. • STORAGE RACK DESIGN for THE BON MARCHE TUC 7M171., 11S717NCTO1 by SANTIAGO C. MANALANG, DESIGN CRITERIA Code: 1933 Uniform Buiding Code Seismic Zone No, 3 Max. Load per Level : 1450# Total (7251 per side) RECEIVED CITY OF TUKVVILA MAY 2 1 1991 PERIVIITCENTES BY ) .4e• Panda" DATE 06- 2-e ll CHKD. BY DATE CLIENT you MAgCli / PA An. MCA DOW S. PROJECT PO PAR Ctka 5TOR-,4Cr AC S' 6-1.1ti SUBJECT 581 2-88 SHEET OF DEPT. OFS NO. NO. . • el f' P 00 s0 o t w + 0, 17 • %. I- A, 0 A • 1 79 i0 4'0/STE8 BY . ,. Pamoia DATE Ds -c2 -gi CHKD. DATE CLIENT 13014 MARCl-ig PROJECT SUBJECT 581 2.88 you M,4.R -Cl6 sran.A( ,ekcic SIDE a LEVAT/otJ Yr ` a r • 4E0 SN5 CTYr SIM ELF.VATI0hi SHEET 2 . OF DEPT. OFS NO. NO T picks. cQoss (312A-cbu q dN� pB�e 4 RAYS 14" Re 0 0 CI Sgg 5 4. ( p) 'ON 'ld3a dO £ 133HS ON SAO 'sar.1. 2r k1 ly-ZI - S 0 31da J'-vi/e Jii-vvert r/ai1 w,Iiii 31tfa 6 filltZ tag 103 r8 r1S 133rOUd 1N31'13 A8 'a)IHO ) ofrd A8 � / / /IVOy 4 C -_ 4144/ I C* 62 o y ar +Q 13779 � O 4 F ' 4 STE R � 1 S'ONA ECG s - so -fir COLUMN II I i \ I -\ Ii �2r1� x 411 PMZhsocT OR AV. - W/ 2� 2 ° MJIi 1 (3FOMF -NT CTYPn a c i.- 'v V 7- G Ii • • / • D a COLUMN = 13A INSTALLATION) 1 =1 S c A 3 = 1'-o TS 6 x4x (' OASE . t_ cotidcRaTg SLA8 f y C m 0 r m Z -i 0 Z rn 0 m 0 -n 07 Z 0 BY S. Cy UQkaAQ►t DATE as /2 - CHKD.BY DATE CLIENT f341.) MO- PROJECT aCq /ARC $TOPAGg_ R-Ac K SUBJECT 581 2.88 SHEET OF DEPT. OFS NO. NO BY • 61 ' 1 DATE _ ej ' s- /1 ' CHKD.BY DATE CLIENT & 1i 444 .1 1 0 PROJECT gOst) MAC4 STa AA cgs SUBJECT MiEMr3$2 P(243 Pe2TI s 581 2-88 MEMIg-. Q It1= MO 4 Mf=M(3pt Q 1 P- (3R M eM !3 E P- I l 2 { fix= 3y�� 1A 12. X 10 7 .Tx;o,Cq f3d-./ 34,8* �. = R >< o,los o. ff �.,. —3 ( X 3 li 1. � _ ©.61 i~, / A q,s ©.lob 1,0 Li 4-4 I 2. Ix _ OS K 33 - 3 I2 S - I.15 = ail Cpvss AISt4 M ENrig2 3/8 6012 Q= q,S'>< 0.4OS 1.0 'c4.'' (04? SHEET 6 OF DEPT. OFS NO NO 4d d2 yO,1oS II��I ��o1 12.,,•=-0.105" i C r a .�,�„� - 1 O ,% Z ' 1.67 4,z r 2 A [3,63-'- 1 d, � q 3 ¢, J 12 I.o4 S-• -op 4 d BY C 4 M ar/44b g DATE 65-12:— II CHKD. BY DATE CLIENT 801C-i MAR-C PROJECT 1301`i imgcN4 sTorzAqa CK SUBJECT 581 248 0 • 0 V = 0 0 0 7 .45so T O1oIJ • ((2.- • • • 72.E 725" t. O 3 , E C W • 71-5 -72s * °•$. C: 217.S gap:42 12 72st (0KSt63.1 tDE-R- VIM (16C Fc* MoldiF-Nr P-P-SISTIN SRISMIC LOAD ' 1-RAML WO- VIO" cA /) rd _ _ [45 _ 108 , 441 Aso . 2 - 0 2 302 14s tar 1 6, OFS NO. y 8 )(i 2(75 04,07 SHEET --- OF DEPT. NO. 5- 26- ? / 805 c Pa Tr. ado A 3 4,3 I BY S.ei►1 DATE Q -�Z -q� CHKD. BY DATE CLIENT I3 A ie.C ►{� PROJECT PYO u M T .4 Cam' SUBJECT Dpsic couitc IJ 044413 CD) Ksi PAX .M a 4_= / 30gs .1" / 2 49t 1 73)6S4, N_ # < _ C v -, 4- S MAX /4 e_ S ) (de)- ,le ac'i rj eTh 07%e Sae oa, l� ) = 154 g 2.0 .f 100 ; (00 + 72 S 112 ( 4? 7/,26 -0 ��- < 73 esa 581 2-88 r y 4,07 TV' = 0,07 X 0.3 x � = (3 0s -1) ; F, = (3os- 1) 4 `3 °2 4 706 F� o (os--i) )( s? 906 AiAx 4ic/A -c. 1.0440 43s 230 psi leeq + 7 M _, :73 = 8 • 534 _ /o t si 4416 Ca L I? i a srrt s ss-s --. • 2 t 0,61 = 4, 79 < 1433 5640 11. -4 MID 52 G >< 72S = 436-0 a -# lex )e h 4,3 �a n 5 ksr OFS NO. «a _. = 4e 27,(,Ari' SHEET 8 OF DEPT. NO By ga Ci ittoo-147 DATE CHKD. BY DATE CLIENT 6 1414 /LCAIE PROJECT gO/ MAlt•COIC grolaA-ae f SUBJECT 581 2-88 OgS/ ark) BASE MO/0g k = 614 • MAX = 73,8S3 8 _ 7385D i F be tom A4c/fort. mot,7 735V 1 luie4GE A-kcmtiee 6 10 io/ 24,7" gxfae-oxig4ir. pe j ) •PL= oF .341 .?_- a ) 4. o, 34, avt■ SO-44 73E5' Wp.44 c-AP • a • • • .......1.06•••••••••••• psi 2.7e YD it 3 3 0 k, Mr:73 •-\-- cot. 11,•••■••••■•••• 41 to 6 1 0 I I t Fi SHEET_____ OF DEPT. OFS NO NO. g• 2 ° -II 13/tsE. 0 &Doc, "Al 0,e? 2 7‘ 2 g =2.cy?# o/c BB1 2413 BY � , 04`04 DATE GS"- / z 4I CHKD.BY DATE CLIENT 114 PROJECT 130N AA/ix-Me- 5 TOR- x4 - A SHEET _ OF DEPT. OFS NO NO. SUBJECT Pa st . _f4 I - j ) X M 72s K f,/ _ 224,065 ;p5j < 0,6 X 4c 2 20g h s % ok BY C 62 ' 144#41-64 DATE CHM). BY DATE CLIENT ta °/-) LtA /44 PROJECT N 4:45-i 44si SUBJECT FOR fmMO PRAM! - V— o,3_x 2 581 2-88 DESterki 1-dOR atzAci.0 M/4/3. sroft4ccte. - 0; isetv 0 SHEET I I OF DEPT. OFS NO NO, TO, c4aoss cij4 ONE. PER 4 AYs. 4 0 0 0 47-4 ‘0 13„ 4x L . A .k„ sb ig-BG ,11 /e36 psi s-01.44 . /06,AL 41 ^WO bt-r test*i ClU) ES-. l3nAcht) 4441 4130 R 77?-y x 2 ' 134-ft • zottp. = - ,G ,c3�v..7 5401 > 2 424 at , . 9 04,hsat caubciAi ,14AH/34,e co IF C1z49 13,c/,&J; kiittiS is abiii,ths r e EL 4-2/2.# d4 60 )( 2 " a 3 oat " SS zr 2 . 65 & 3 Of) ,t 2 75/ 3 ) hrt 3 • • 4 4 • 6 K 3 30000 • - • = 2/ 4.G)t 4 elOre ok. CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUKWILA. {WASHINGTON 08188 Plan Check #91 -207: The Bon 17000 Southcenter Parkway PHONE II (206) 433.1800 Gary L. VanDusra. Mayor THE FOLLOWING COMMENTS APPLY TO AND BECOME rP.RT Q THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER 0,00 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 3. When special inspection is required either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 4. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 5. All high - strength bolting to be special inspected (Sec. 306, UBC). 6. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washignton State Energy Code (1989 Edition), and Washington State Regulations for Barrier Free Facility (1989 Edition). 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. "X" REQUIRED INSPECTIONS PHONE APPROVED INITIALS CORRECTION NOTICE ISSUED '— 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 7 Framing 431 -3670 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 10 Wall Board Fastening 431 -3670 X 11 Bolts X 1 Welding 13 X 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 X 17 BUILDING FINAL 431 -3670 BUILDI!G PERMIT INSPECTION RECORD (Post with Building Permit In conspicuous place) CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: 17000 Southcenter Parkway SUITE NO : BUILDING PERMIT NO. DATE ISSUED: PROJECT: The Bon CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (INSPECTOR COMMENT SECTION ON REVERSE) INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or If underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. mow PLAN REVIEW COMMENTS Plan Check No.: q I "2-0 Project: 14 -a �! REQUIRED INSPECTIONS No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be Inspected by that agency, including all gas piping (296- 4722). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277 - 7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. I X All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. ar When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). X All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). R' All high - strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 11. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire rotardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. 1. Footings 2. Foundation 3. Slab /Slab Insulation 4. Shear Wall Nailing 5. Roof Sheathing Nailing 6. Masonry Chimney 7. Framing 8. Insulation 9. Suspended Ceiling 10. Wall Board Fastening X 12. We AnDI Ku_ 13. X 14. Fire Final 15. Planning Final 16. Public Works Final X 17. Building Final PLAN REVIEW COMMENTS Plan Check No.: q I "2-0 Project: 14 -a �! REQUIRED INSPECTIONS No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be Inspected by that agency, including all gas piping (296- 4722). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277 - 7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. I X All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. ar When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). X All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). R' All high - strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 11. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire rotardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. Dear Sir: City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review (513) Control #91 -207 May 28, 1991 Re: The Bon Marcr:e, Distribution Center - 17000 Southcenter Boulevard, Tukwila, Wa. Gary L. VanDusen, Mayor The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 3302.(d)) 3. All sprinkler drawings shall be prepared by licensed to perform this type of work. Drawings shall first be approved by the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528 & NFPA 13, 1•-9.1) (UFC 10.305) In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 231C 4-3.1) All sprinkler drawings shall be prepared by companies licensed to perform this type of work. Drawings shall first be approved :by the Washington Survey & Rating Bureau, Factory Mutual Engineering or .Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528 & NFPA 13, 1 -9.1) (UFC 10.305) 4. A permit is reauired for storage of high-Piled City of Tukwila Page number 2 combustible stock. An application is enclosed. (UFC 81.103) If the building is to be used for the storage of high -piled combustible material (as defined in UFC, Sec. 9.110); automatic fire - extinguishing systems, smoke-removal systems, fire protection and fire separations are required per Uniform Fire Code Article 81. Smoke removal capability shall be provided in buildings used for' the storage of high -piled combustible stock and protected by an automatic fire - extinguishing system and shall be designed to provide a minimum of six changes of air per hour at 100 percent exhaust to the outside. (UFC 81.10.7a) Any overlooked hazardous condition. and/or. violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. File slj FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Gary L. VanDusen, Mayor CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 ADDRESS: PROJECT: agd t'J o c U 5 u C ev, r 1 4 : 3/ ~l DATE: 1 .5m e4,6 lr= CJC I T PLAN REVIEW PLAN CHECK NUMBER 'Q.m \ftay.' n C6 wv s - r 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 Prepared by: —. hibay racking addition