Loading...
HomeMy WebLinkAboutPermit 6610 - Boeing #7-33 - OfficePermit 6610 - Boeing #7-33 . • • 1 1: III - N 1 ' ' • ` y ear 1988 SETBACKS: N - S - E- W- FIRE PROTECTION: g Sprinklers Detectors ❑ p ❑ ❑ N/A UTILITY PERMITS REQUIRED? Yes ❑ �' roug o p Public Works) ® No ZONING: BAR/LAND USE CONDITIONS? ❑ Yes ® No CONDITIONS (other than those noted on or attached to permit/plans) 1 �r CITY OF TUKWILA Dept. of Community Development - Building 6300 Southcenter Boulevard, Tukwila WA (206) 431 -3670 BUILDING PERMIT NO. DATE ISSUED: SITE ADDR SS PROJECT NAME/TENANT ADDRESS CONTRACTOR ADDRESS ARCHITECT ADDRESS ToTAt APPROVED FOR ISSUANCE BY: SIGNATURE: K --7 12687 Gateway Dr Boeing #7 -33 TYPE OF U New Building Ii Addition WORK: ❑ Rack Storage ❑ Reroof DESCRIBE WORK TO BE DONE: Addition of Bedford Properties 12720 Gateway Drive, Suite•107, Seattle, WA 4055 Lake Washin WA. ST. CONTRACTOR'S LICENSE # KBINTCC160QF BE & C Engineers CODE COMPLIANCE SQUARE OCC. SQUARE OCC. SQUARE OCC. OCC. O TOTAL SQUARE FEET SQUARE FEET OCC. LOAD O dtk I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of lav and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. PRINT NAME: 6 GE?JI.) CA Ie . Thisp ertrnt. issuanc CERTIFICATE OF OCCUPANCY NO. Division 98188 one office. KB Interior Construction Co. 14675 Interurban Avenue South, Seattle, WA 4ric BUILDIW'3 PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) DESCRIPTION:; BUILDING:: PERMIT. FEE::;:; PLAN :CHECK :FEE BUILDING.SURCHARGE:1 .; FEES Ar+AOUNT; TOTAL:: RCPT: #: PLAN CHECK NO.: SUITE # ton Boulevard, Kirkland, WA BUILDING t. OFFICIAL DATE: ‘14 91 -194 VAL E OF CONSTRUCTION - $ 10,000.00 ASSESSOR ACCOUNT # 000480 - 0008 - (jJ Tenant Improvement (commercial) U Demolition (building) U Grading/Fill ❑ Remodel (residential) ❑ Other: 241 -1103 ZIP 98168 PHONE 889 -9400 EXP. DATE PHONE 393 -8411 DATE: _ e COMPANY: 1 a L= / i (r ZIP 98083 -0849 3 -31 -92 ZIP 98168 shall `become null and tpd rf the work is not commenced wnthin 1 frotl't the ed if the work �s suspended ar aba fora period of ,180 ; days from the, last insF DATE ISSUED: i TOTAL CC LOAD PERMIT NO. CONTACTED C...I(i DATE READY DATE NOTIFIED rr — oa�—*"t I BY: (init.) BY: (snit.) BY: (Init.) 13 PERMIT EXPIRES 2nd NOTIFICATION 3RD NOTIFICATION AMOUNT OWING J • 50 PLAN CHECK NUMBER c of INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized In writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) SQUARE FEET OCC. LOAD SQUARE OCC. SQUARE OCC. FEET LOAD FEET LOAD SQUARE FEET SQUARE FEET OCC. LOAD OCC. LOAD TOTAL SQUARE FEET DEPARTMENTAL REVIEW "X" in box Indicates which departments need to review the project. BUILDING - initial review O PUBLIC WORKS O OTHER 51 BUILDING - final review INIT: INIT: lA.._ UTILITY PERMITS REQUIRED? PUBLIC WORKS LETTER DATED: TYPE OF CO STRUCT • N: UBC EDITION (year): REVIEW COMPLETED PROJECT NAME SITE ADDRESS BUILDING lERMIT APPLICATION TRACKING 15-32i r5 3" lal��`1 C°tokinut br m - : UIREMM�M ' S: ! C(IyINMUM CONSULTANT: Date Sent Date Approved FIRE PROTECTION: S. rinklers Detectors N/A FIRE DEPT. LETTER DATED: 5 "y - ' INSPECTOR: dr, 3, ZONING: REFERENCE FILE NOS.: MINIMUM SETBACKS: N- SUITE NO. BAR/LAND USE CONDITIONS? Yes _t `a? (9, 8 TOTAL OCC. LOAD No 0:1 Y. CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 UILDING PERMIT :?FEE::;. UILDING SURCHARGE`. PLAN CHECK NUMBER APPLICATION MUST PE FILLED OUT C.OMPL ETEL Y SITE ADDRESS PROJECT NAME/TENANT M r f Tv/ Ho TYPE OF (i New Building U Addition WORK: O Rack Storage 0 Reroof DESCRIBE WORK TO BE DONE: At7r7 /1?oAJ roe c f/ce BUILDING USE (office, warehouse, etc.) r f /G. 1 S7ziaos NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE ?A No U Yes IF YES, EXPLAIN: SQUARE FOOTAGE - Building: 4 /, -24z Tenant Space: 4/ , 2_4 z Area of Construction: / WILL THERE BE STOR GE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 0 No Yes IF YES, EXPLAIN: TH�ee% , ' TLVO ex/.S 7 sire)/.,re 44640e73 (F -404441 E 4QU /as) /N TJe f6C1 /4.O /AJ y , .uo r Gcc;q-re/J /.0 77/e - as , Z' Z , A-- PROPERTY OWNER /?zop1'E -S (Gr oK E ) 1Z7 go �A AJ ' ae/V / 4 `l� 7 ,� / e,4 r -ee ADDRESS CONTRACTOR ADDRESS ,1c 7 /ati l c. ' /.cr, 2ja/25 u sT, G' 4 0 5 ' 5 ^ GA-ge N A s / / / 4 / C 7 - T b / J v d k i r lan c0 , L'O A EXP. DATE j _ 3 1 _ G2 WA. ST. CONTRACTOR'S LICENSE # ARCHITECT 00 , G e,Q4C.S ADDRESS /4107 - 7,i ize.0ov Ave.. AR BUILDING OWNER OR AUTHORIZED AGENT 'CONTACT PERSON SIGNATURE DATE APPLICATION ACCEPTED 5-m-q) A UTHOR IZ E AAA U EXAM IN PRINT NAME s7wp ADDRESS /1 00 771-L13 ,ea. So erLCC S''774. BUILDII PERMIT APPLICATION Tv V/G-G VALUE OF CONSTRUCTION - $ ASSESSOR ACCOUNT # x¢80- 0 - •g Tenant Improvement (commercial) U Demolition (building) 0 Remodel (residential) 0 Other DATE APPLICATION EXPIRES PHONE / - //o3 ZIPc18 /1 PHONE gif _c# Zl P qp3 - PHONE 393 -,25548 DAl E 5 / / PHONE 3 CITY /ZIP c18 C) , PHONE 3cj3 Zq / ,�, APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. 07106/90 COMMERCIAL ...• • • • ." • " " • NEW COMMERCIAL BUILDINGS/ADDITIONS " • •• ,••••-• •••••••••:".:'••••• 0 Completed building permit application (One for each . :: • •.• • •,:,•••:: •••••• : . : : ..• ••••••::•••••••••••::::: , 1:::1'AssesSOf Account Number • • .,. • Two sets (2) of the Specifications. • ::.••••!:•..., :',•.•••••• • ••••••• Structural calculations stamped Oy.a.WasfOrOcai•,pyiaa:POonaad.",".:":.:••: engineer • . ••:::.:•••••••••: • Soil k report:tarnpedbye Washington 'State licensed anin�ur . ..• ,, , , . , . • • „„. • E].TOpcigrapi riurvey EnargY calculations stamped by aWasttingtrini:Stateticertsedi.:: • , ..engineer Of architect: • • 1 • , • • • '•:" • • • • :•••: :••• ••• 1 .•Legal description ,••,•••:-.:•••,•••":••• •• • -1' , •WOtking drawings, stamped by a Washington Stale licensed architect, which include•::. . I • : . „11 ,, Site plan • •••h'••••••::' • :•::•...:„ drawings . • • Structural drawings:: Mechanical drawings :::••• :• • • • • Elevations: -:•(::••• • ••• • •• ••: • •• • • :•••••••••:•:: Civil drawinge.: 'Landscape plan :: • : • 1 1 Completed utility permit application (one for entire Ej Six (6) riettrof•civitdrawinge••• • •NOTE.'..]:$40: toffitY pennitapOlication sod olleS4clist subrnittal RACK STORAGE •. exits. • • RESIDENTIAL • • • . Completed building permit • • • • applicati •••••••••••••••••••••••••••:,,:•.•-•:,••••••.•:•:::::,:•,........::::::•....:::::••:.:::.::::•::::.,:......•;::. Assessor Account • . • • Two (2) sets of plans, which • i nc l u d . ..:•••.: uildlng floor. plan showing • • • ••• • ::::::••••••••.•,••::•:•••'•••••••••••••••••■ Eritire•sp•ao3 wherelrackri will be located • Exit doors Of Tenant Oacc.:floOr.ofoO::altO0 reck.."sto.tefe:.ittyput,...e4 WI! i .;,......• : ::,:: . . : . : :: :: :::::: . . : ,.. : • : •• • ••,:.: : :•.::•. : :• : ,:•,• : •::: : •••.:.. ? :::::: : .•.:., ; .:„...:,..::......:••::.:•....„.....:•. : : : . : ,...:•: : :,...,• : : : . : .::: : : : :::.,,,, , ,:•,, , ,-, : ••••..: : :•....:::: : :.,•:.:•-•: NEtk.61NOLEFAIIIL'fO.WELI,IikiGS/ADOrl.)Ofiti.'•••::'::::•:•• :.....• .• • ......................................••••.• ... ... • • • • • • ••• • •••••• ,,,,, ••..: • • ••. .„.... :..........„,,...„.:...„.............:........:..- .:. :„.,, .. ....... ........: ,,, , .. ...• . . . ....„„ ., ,.. •..... Completed building permit application .for:::.pi■pf:sfo4ofAirs) .•••••• • • ••••......,....,....:::„.„.....,•:: .... ...;.,......::::,....,...........:;::::.:::......;.:.......„.• „..............: , ., . ••••••••...•••••••••••••..„.::::„....„.......,•,:•„:..............:.:.....,,..„.., • . ' . • • ..:::::....:,.: ' t .egal•descriptici r t.'•:•;•••••••,.?::::...:::: :: ::::::: : ::;•.: . ::.;0:::y:::::::::: : :::::::::•4::•!..:::;;;,:il . •:::::.1::::::ai::::::.if,... , •••,:::!.••:::.::;:••••:::::: , .. , .;:•:•••:::::::::,::::::.::....:.:.: •••.............. Assessor OTW.Osels.(2Ycif working draWings;:whickirteltitia:1:•5::':••••: Site ..• .• • •.•..•...,.:. • :.• Plaff Floor ....... . .... ........ .• . • ......... . . plan Roof plan. Builcng elevations (all views) . ' Building cross section • Stnrctural framing 'plans .Washington State Energy Qode data ••Completed utility permit application SUBMITTAL CHECKLIST Six (6) sets of site plans showing utilibes • : • : NOTE Building site plan and utility site plan may be Oorobtrieek::Seel::;:. utility permit application and checklist for speOlfloSdbmittelreqekements.: Additional toppgrappical and soils informativn mar be mthd site conditions. '. • • COMMERCIAL TENANT SM Era f;eit Afi te ... 11 *,00' n11;i11' ;7 ........... ..... wh ich .................................................................................................................................................................................................... Two . Oft: of.Opo ................... • • Site plan • • Location t of tenant space • Tenant location •••••• • building p PVer10 attiacppt.:*!: .... . .... Floor P of pro posed • • • NOW ait:63.° Tei,:f e iI g tr:3 1 ,1110 . wall, anl waits to be demolished • • • • • C°1•.:1!tf.- uct sections showIng wall eisff0 !°I.°83 11418°11 moot for floor and 'Stru*til0•Gel9uittio ito b :W �nsed • iriber, orft dono permi sepa rate . .. .... .„. ‘. .. .... . . . . . . ... • • (ore for . . . • , • .. . . .. Assessor AiXount Number: •• Narrative describing existing roof material being removed and ...materiel; being installect,'•::, • . NOTE: ,A Oertiffoatioa letter Is ro4vorci okfor 0•#/v110411:iectivii and si4 oft of ,t119 . • . ' . . •••••'' • •.: . •:••• ..................................................................................... • • ... ' • • PROJECT: 4fi 7-55 , P PERMIT NO. 6 6 D SITE ADDRESS /'( gl 1 ,�,c.Q) D DATE CALLED: 6 6 - 2?- ei / TYPE OF INSPECTION: . 4f , v D DATE WANTED: — — ' ql P. CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431:3670 INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: kJ; . a• 33 PERMIT NO. I I () SITE ADDRESS: IWO% el (3., 0 s t)r DATE CALLED: (17--&i-q1 ---0.)11. TYPE OF INSPECTION: littilm i .. cc- DATE WANTED: p ib I • . m . SPECIAL INSTRUCTIONS: REQUESTER: P-ek-e. PHONE NO.: • . I '5 el 0 INSPECTION RESULTS/COMMENTS: - 7" --- CL' (i-rel- / i , tt fl be -c ' ' .1 7 DATE: INSPECTOR: CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431-3670 INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: + i' PERMIT NO. i i • SITE ADDRESS: ��~ �- � ir7r /, _ � DATE CALLED: (0 /S TYPE OF INSPECTION: I ' DATE WANTED: i �--- ia� REQUESTER: `�/�i ',NW SPECIAL INSTRUCTIONS: PHONE NO.: 4.. --- o r ��7; „ INSPECTION RESULTS /COMMENTS: INSPECTOR: i < Ar.., DATE: -- CITY OF TUKW1LA Dept. of Community Development - Building Division Phone: (206) 431-3670 INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: gBrwraIIIIIIIIw'NEIr4. , ,,,, _ ___, ... 0 PERMIT NO. , i 0 DATE CALLED: — j' q 1 SITE ADDRESS: 4. , : F AIMOMIIIMS7W2 I TYPE OF INSPECTION: 4,111 .ario DATE WANTED: e / 7 ! SPECIAL INSTRUCTIONS: ir REQUESTER: I PHONE NO.: 40-67/ /all I INSPECTION RESULTS/COMMENTS: ....-^ ■-.,, ..,..c. L ThOQ ciskle c WC EICONTAl2. I II ATC. 63 - I CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431-3670 INSPECTION RECORD 6300 SouthceRter Boulevard — #100 Tukwila Washington 98188 PROJECT: 0 3 PERMIT NO. 1470 SITE ADDRESS: 2!. DATE CALLED: r; ^- / 3 DATE WANTED: - ----q TYPE OF INSPECTION: FL/ " I , S - CTIONS: 7 � 1 A .- REGIUESTER: 4 Q � r .- do ( !� /. PHONE NO.: q7/ 6202 INSPECTIO RESULTS /COMMENTS: tL% e d'� ' -/ / ^ /.r --GP GI' / _L!�- et0�..Z Yom-, INSPECTOR: �_,,, DATE: 6 -f -.--l CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431-3670 c ovc INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 C City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Project Name Address Suite # Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Authorized Signature Date JUL 011991 D Cli 'Y L* TUKVVILA PLANNING DEPT. Gary L. VanDusen, Mayor Control No. Permit No. FINALAPP.FRM T.F.D. Form F.P. 85 CITY OF TUKWILA tom SOUTIICENTER BOULEVARD, TUKWILA, WASHINGTON 98188 Plan Check #91 -194: Boeing #7 -33 12687 Gateway Dr PNUNE N 131161.133.1800 Gan L. Vui1)usen, Mayor THE PLANS FOLLOWING AND BECOME UNDER TUKWILA BUILDING PERMIT NUMBER QQI1 THE APPROVED F 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (277- 7272). 3. All mechanical work shall be under separate permit through the City of Tukwila. 4. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 5. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 6. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 7. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 8. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 9. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. "X" REQUIRED INSPECTIONS PHONE AP DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 X 7 Framing 431 -3670 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 X 10 Wall Board Fastening 431 -3670 • 11 12 13 X 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 X 17 BUILDING FINAL 431 -3670 CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: 12687 Gateway Dr BUILDWG PERMIT INSPECTION RECORD (Post with Building Permit In conspicuous place) SUITE NO.: BUILDING PERMIT NO. DATE ISSUED: PROJECT: Boeing #7 -33 CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (INSPECTOR COMMENT SECTION ON REVERSE) INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if undersiab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -1n Inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is In place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not. required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. mom r E, PLAN REVIEW COMMENTS Plan Check No.: q I ` I 41 Project: REQUIRED INSPECTIONS X No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, Including all gas piping (296 - 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277 - 7272). All mechanical work shall be under separate permit through the City of ✓� Tukwila. X All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special Inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high - strength bolting to be special inspected (Sec. 306, UBC). X Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. X Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department,approval, it is the contractors responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. ..X.41 Validity of Permit. The Issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the Jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. 1. Footings 2. Foundation 3. Slab /Slab Insulation 4. Shear Wall Nailing 5. Roof Sheathing Nailing 6. Masonry Chimney X 7. Framing 8. Insulation 9. Suspended Ceiling X 10. Wall Board Fastening 11. 12. 13. )< 14. Fire Final 15. Planning Final 16. Public Works Final X 17. Building Final r E, PLAN REVIEW COMMENTS Plan Check No.: q I ` I 41 Project: REQUIRED INSPECTIONS X No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, Including all gas piping (296 - 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277 - 7272). All mechanical work shall be under separate permit through the City of ✓� Tukwila. X All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special Inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high - strength bolting to be special inspected (Sec. 306, UBC). X Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. X Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department,approval, it is the contractors responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. ..X.41 Validity of Permit. The Issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the Jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. �J oti1LA 4 City of Tukwila y FIRE DEPARTMENT 444 Andover Park East a Q Tukwila, Washington 98188 -7661 (206) 575-4404 Gary L. VanDusen, Mayor Fire Department Review (513) Control Number 91 -194 May 17, 1991 Re: The Boeing Company - 12687 Gateway Drive, Building #733, Tukwila, Wa. Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. 2. Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 10.402(a). Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) 3. Maintain sprinkler protection for all enclosed areas. (NFPA 13, 4- 1.1.1) (UFC 10.302) All sprinkler drawings shall be prepared by companies licensed to perform this type of work. Drawings shall first be approved by the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528 & NFPA 13, 1-9.1) (UFC 10.305) 4. All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) All interior wall covering materials shall be y slj City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 2 Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. File Gary L. VanDusen, Mayor fire - resistive or shall be treated to be fire - resistive, so as to result in a flame- spread rating as required by UFC Appendix VI -C tables 42A and 42B. A certificate of the flame spread rating is required to be delivered to the Tukwila Fire Department. (UBC 4204) (UFC 10.401.) PLAN REVIEW CITY OF TUKWILA Department of Community Development - Building Division Phone: (206) 431 -3670 PROJECT: ADDRESS: DATE: f Vy,A Y t 5 , I' G 1 f Kesiz_-- 1 m (0 .4-- 2- I. OCCUPANCY GROUP TYPE OF CONSTRUCTION LOCATION ON PROPERTY .r ,4 a r BUILDING HEIGHT /# OF STORIES V �� I dB 0 FLOOR AREA OCCUPANT LOAD EXITING REQUIREMENTS DETAILED REQUIREMENTS OCCUPANCY TYPE OF CONSTRUCTION NOTES PREPARED BY: NI •4'51 /&.a( -, PART V, CHAPTER 23, U.B.C. W.S.E.C. CHAPTER 51-10, W.A.C. i. 7 / K) (9 CI~ 0 /. 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PLAN CHECK NUMBER DATE: t ,Gk eP4 � + O{ e n C{,c. �ev� � Oat piS sue ..�. <; ,�r`'� `+�� G { . any t � ���d�'� GC �a + {O(1 '•� v:��`� U{ con uc does dot a orti∎ ,%,,,: r � tr��,,;�vted9 d. �,1r d code or {avedp11�' di t C actor SCUP /I 0 ate ADS ADS ADS DATE SYM 5.27.87 6 -12 -87 6 -25 -87 7 -24 -87 5.8.91 APPROVED BY COVER SHEET AND PROJECT DATA TITLE MOTION PICTURE AND TV AREA BUILDING 7 -33 GATEWAY BUILDING '4 INDEX REVISION 87059 sOl'' 409 PQ 0 s OA AREA OF BUILDING TENANT IMPROVEMENTS -. _... - ......,0.010_........._ . ,....r. _�.�....._...� - SITE MAP VICINITY MAP REVISION ........_.�. .,.........- 0000.._ ISSUED FOR BUILDING PERMIT REVIEW EVIEW 9 0 9C .- - �..- ,�...- ...M... ISSUED FOR CONSTRUCTION �....e..,.._......- 0000. . LOBBY RELOCATION INDEX REVISION JOB S 91012 -062 BY .....__ .............•∎••.* wm.a...Y ftabsSIO.M■•w.Apb...4..efte..00gioiwoNIMOW....0M.MM..■o*IONO M M OMOMMV.MM.d REFER TO CIVIL DRAWINGS FOR TENANT IMPROVEMENT RELATED SITE WORK SITE .I..- ....0111•■•■■••■•-. PARCEL A: ALL THAT PORTION OF THE CYRUS C. LEWIS DONATION CLAIM NO. 37, LYING IN SECTIONS 10 AND 15, TOWNSHIP 23 NORTH, RANGE 4 EAST w.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE NORTHEASTERLY MARGIN OF THE PUGET SOUND POWER & LIGHT COMPANY RIGHT OF WAY, SAID POINT BEING NORTH 22 °20'26" WEST FROM THE QUARTER CORNER BETWEEN SECTIONS 14 AND 15, A DISTANCE OF 1,722.57 FEET BASED ON THE NORTH ZONE LAMBERT GRID SYSTEM FOR THE STATE OF WASHINGTON, SAID POINT BEING ALSO THE SOUTHWEST CORNER OF THAT CERTAIN TRACT OF LAND CONVEYED TO FRANK MENAGLIA AND VITTORIE DEMARCKI, AS RECORDED IN VOLUME 1513 OF DEEDS, PAGE 13, IN KING COUNTY RECORDING NO. 2693164; THENCE NORTH 48 °13'44" WEST ALONG SAID NORTHEASTERLY MARGIN 1,770.27 FEET TO THE POINT OF BEGINNING; THENCE NORTH 41 °46'16" EAST 179.27 FEET; THENCE NORTH 81 °30'14" WEST 45.00 FEET; THENCE SOUTH 28 °05'42" WEST 159.11 FEET TO THE TRUE POINT OF BEGINNING. PARCEL B: OOMI TI N BUILDING 7 -33 (GATEWAY BUILDI 1 GATEWAY DRIVE SEATTLE, WASHINGTON 95168 LEGAL DESCRIPTION A NON - EXCLUSIVE EASEMENT FOR INGRESS AND EGRESS IN AND ACROSS THE FOLLOWING DESCRIBED PROPERTY: A STRIP OF LAND, 20.0 FEET IN WIDTH AS MEASURED AT RIGHT ANGLES TO AND LYING SOUTHERLY OF A LINE DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE NORTHEASTERLY MARGIN OF THE PUGET SOUND POWER & LIGHT CO. RIGHT -OF -WAY, NORTH 22 °20'26" WEST, FROM THE QUARTER CORNER BETWEEN SECTIONS 14 AND 15, A DISTANCE OF 1,722.57 FEET BASED ON THE NORTH ZONE LAMBERT GRID SYSTEM FOR THE STATE OF WASHINGTON, SAID POINT OF BEGINNING BEING ALSO THE S.W. CORNER OF THAT CERTAIN TRACT OF LAND CONVEYED TO FRANK MENAGLIA AND VITTORIE DEMARCKI AS RECORDED IN VOLUME 1513 OF DEEDS, PAGE 121 RECORDS OF THE AUDITOR OF KING COUNTY, WASHINGTON, UNDER RECORDING NO. 2693164, SEPTEMBER 25, 1931; THENCE NORTH 48° 13' 44" WEST ALONG SAID NORTHEASTERLY MARGIN 1,570.27 FEET; THENCE NORTH 41 °46'16" EAST 310.54 FEET; T H E N C E NORTH 8°29'46" EAST 2 0 . 0 F E E T T O THE TRUE POINT OF BEGINNING OF THE ABOVE MENTIONED DESCRIPTION LINE; THENCE ALONG SAID DESCRIPTION LINE, NORTH 81 °30'14" WEST 595.37 FEET TO THE NORTHEASTERLY MARGIN OF THE PUGET SOUND POWER & LIGHT CO. RIGHT-OF-WAY; TOGETHER WITH A STRIP OF LAND 16.0 FEET IN WIDTH EXTENDING FROM THE MOST WESTERLY CORNER OF THE ABOVE DESCRIBED EASEMENT, NORTHWESTERLY ALONG THE NORTHEASTERLY MARGIN OF THE PUGET SOUND POWER & LIGHT CO. RIGHT -OF --WAY A DISTANCE OF 190.0 FEET, WORE OR LESS, TO A ROAD CROSSING SAID RIGHT -OF -WAY BEING KNOWN AS 42ND AVENUE SOUTH. EXCEPT ANY PORTION WHICH MAY LIE WITHIN PARCEL A. SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. REVISION TENANT IMPROVEMENTS RJR ......._ •.. ...... -..OIA ....._..,..- ..w.......,- 0000.._ °1L FACILITIES DEPARTMENT PROJECT DESCRIPTION: TENANT IMPROVEMENTS TO EXISTING BUILDING FOR A MOTION PICTURE AND VIDEO PRODUCTION FACILITY. LAND USE ZONE: M1 (LIGHT INDUSTRIAL) GROSS AREA OF TENANT IMPROVEMENTS. 120 SF PARKING REQUIRED AT 2.5 PER 1000 GSF: 64 GATEWAY BUILDING 14 GROSS FLOOR AREA: 40,971 SF BUILDING CODE: 1985 UBC OCCUPANCY GROUP: B2 CONSTRUCTION TYPE: ITI N - SPRINKLERED NUMBER OF EMPLOYEES (INCLUDING OFF -SITE CAMERA CREWS): 50 MAXIMUM SIMULTANEOUS VISITORS: 20 ENERGY CODE LIGHTING BUDGET: GENERAL OFFICE AREAS 1.7 WATTS /SF 1. THE BUILDING SHALL BE FIRE SPRINKLERED THROUGHOUT. 2. ALL EXTERIOR WALL FURRING AND FRAMING SHALL BE NON-COMBUSTIBLE. 3. ALL DOORS INTO CORRIDORS AND INTO THE MECHANICAL ROOM SHALL BE 20 MINUTE RATED AND SHALL BE SELF - CLOSING OR SMOKE DETECTOR ACTUATED AUTOMATIC CLOSING. 4. ALL RELITES ON CORRIDORS SHALL BE 1/4" WIRED GLASS IN STEEL FRAMES. 5. MINIMUM CORRIDOR ILLUMINATION SHALL BE ONE FOOTCANDLE AT FLOOR LEVEL. 6. ILLUMINATED EXIT SIGNS SHALL BE PROVIDED AT ALL EXIT DOORWAYS FROM CORRIDORS. 7. NO CELLULOSE NITRATE FILM WILL BE USED OR STORED IN THE BUILDING. 8. THE PROJECTION ROOM SHALL BE PROVIDED WITH "SAFETY FILM..." SIGN AS REQUIRED BY THE 1985 UBC. 9. ONLY SAFETY FILM WILL BE USED IN THE PROJECTION ROOM. 10. ONLY ONE PROJECTION MACHINE, FULLY AUTOMATIC, WILL BE USED IN THE PROJECTION ROOM. 11. ALL DOOR HARDWARE, TOILET ROOM ACCESSORIES, AND THE DRINKING FOUNTAIN SHALL COMPLY WITH THE LATEST ADOPTED EDITION OF THE WASHINGTON STATE BARRIER•FREE REGULATIONS. 12. THE SUSPENDED CEILING SYSTEM, INCLUDING LIGHTING FIXTURES, SHALL COMPLY WITH UBC STANDARD 47 -18. 13. PLUMBING FIXTURE COUNT BASED ON ACTUAL EMPLOYEE AND VISITOR COUNTS PER 5 -01 -87 A. SHAW TELEPHONE CONFERENCE WITH JOHN MCALERNEY AT KING COUNTY HEALTH DEPARTMENT. GENERAL NOTES CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS. ADVISE THE ENGINEER OF ANY DISCREPANCIES. CONTRACTOR SHALL VERIFY LOCATION, DIMENSIONS AND ANCHORAGES OF ALL EQUIPMENT AND ACCESSORIES TO BE INSTALLED. DIMENSIONING IS AS FOLLOWS: TO TOP OF EXISTING CONCRETE FLOOR SLAB TO EXISTING COLUMN GRID LINES TO FACE OF EXISTING CONCRETE WALLS TO FACE OF STUDS FOR FRAMED WALLS AND PARTITIONS T O CENTERLINE OF COLUMNS AND BEAMS BACKGROUND PLANS AND SECTIONS ON MECHANICAL, ELECTRICAL, STRUCTURAL AND CIVIL DRAWINGS ARE BACKGROUNDS ONLY. REFER TO ARCHITECTURAL FOR DIMENSIONS AND CONSTRUCTION OF GENERAL CONSTRUCTION. 5 CONTRACTOR SHALL PROVIDE CUTTING AND PATCHING AS REQUIRED FOR INSTALLATION OF MECHANICAL AND ELECTRICAL WORK. 6. ALL DOUBLE WALLS AND DOUBLE CEILINGS, AND ALL WALLS WITH MULTIPLE LAYERS OF GYPSUM BOARD, ARE ACOUSTICAL WALLS. ALL PENETRATIONS SHALL BE CLOSED UP TIGHT TO THE PENETRATING ELEMENT AND SEALED ALL AROUND WITH ACOUSTICAL SEALANT TO PRODUCE AN AIRTIGHT SEPARATION BETWEEN ROOMS. CODE DATA CODE NOTES 0 AUBURN, WA. 98002 O BELLEVUE, WA. 98007 O EVERETT, WA. 98201 O KENT, WA. 98031 Li PORTLAND, OR. 97220 O RENTON, WA. 98055 SEATTLE, WA. 98124 III III II! IIl III III III �III III III l I I I ICI ! I ! i I i I I i I (! l I (I I i I I ! !III III III II.' • 4 • '"_(: .. ,. .... " ' � .. <.,.`.� , � „ � . " " I I I I I I I► I I I IV..I I I I I I I I I I I I I I 1 i l I I I I I I I I I I IIIIIIIII 11111lIII'ITIIIIIIIIIIIII '1 1111'11IIIIII111111I111I11 '1111111111111 0 16THSINCH 1 2 : 3 4 5 6 7 8 9 10 11 MADEIN61RM*HV 12 NOTE: If the microfilmed document is less clear than this notice, it is due to the quality of the Qriginal. document. 06 6Z 8G aZ SZ 1 7Z CZ ZZ LZ 0Z 6L 8L cI. 9 Si ' iL Et Zl !. 0E 6 8 L. 9 51 47 E z ww 11, I..• 0 11l111ni! I MITI II111lIII 111111111 nIIIIIIIIIIIII!���,Illllilld il! II( ICI, �I �!! I II ll1f !!!IIIIIIIIIIII!ll,I�IIIIIIIIII IIII! IIIII! IiIIIII�IIIIIIIIIIIIIIIIIIIINIII III! I, it! fUIIJlilin111111iln1111111innli1nin111 11111n1I111lilnli1ni11111111111111IIIIII111111n111111lll� 1 1. .1 111 NC G -1 C -I C -2 C -3 C -4 O A -1 A -1A A -2 A -3 A -4 0 A -5 A A -6 O A -7 A -7A A -8 • A -9 A -10 A -11 A -12 A -13 A -14 S-.1 S -2 S -3 M -1 M-2 U -3 M -4 0 I M-10 M -1 1 M -12 M -110 M -111 M -•260 M -261 M -262 M -500 M -501 M -502 M -503 M -504 0 M-100 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED ELEVIS ION 41 TITLE GENERAL COVER SHEET AND PROJECT DATA CIVIL SITE LAYOUT PLAN SITE GRADING PLAN SITE UTILITIES PLAN SITE DOMESTIC WATER PLAN ARCH I TECTURAL FIRST FLOOR PLAN - WEST FIRST FLOOR PLAN - EAST SECTIONS AND ELEVATIONS WALL SECTIONS & ROOF PLAN INTERIOR DETAILS FINISH & DOOR SCHEDULES PARTITION TYPES REFLECTED CEILING PLAN - *EST REFLECTED CEILING PLAN - EAST AUDIO AREA & MISC DETAILS DOOR DETAILS MISC. DETAILS STUDIO FIXED GRID & TRACKS CEILING FRAMING PLAN - WEST CEILING FRAMING PLAN - EAST MISC. DETAILS STRUCTURAL STUDIO CEILING FRAMING & DETAILS MISC. DETAILS HVAC DUCT & EQUIPMENT SUPPORTS E -1 INDEX & SYMBOLS E -4 ONE -LINE DIAGRAM E -6 PAGING, AT & TELEPHONES 40 E-7 DATA CABLE SYSTEM E -8 OUTDOOR LIGHTING (-9 GROUNDING 40 I E -10 LIGHTING PLAN E -11 LIGHTING PLAN 40E -60 120/208 VOLT POWER E -61 120/208 VOLT POWER E -110 277/480 VOLT POWER E -111 277/480 VOLT POWER E -5O0 MOTOR CONTROL DIAGRAM MCC -1 40 IE -501 LIGHTING SCHEDULE & DETAILS E -502 DETAILS (-50 STUDIO PLANS & DETAILS INDEX OF DRAWINGS I FOR REFERENCE ONLY I I FOR REFERENCE ONLY 1 MECHAN I CAL MECHANICAL LEGEND & ABBREVIATIONS MECHANICAL LEGEND & ABBREVIATIONS MECHANICAL SCHEDULES MECHANICAL SCHEDULES HVAC PLAN FIRST FLOOR WEST HVAC PLAN FIRST FLOOR EAST HVAC EQUIPMENT ROOM PLAN PLUMBING & UTILITIES PLAN FIRST FLOOR WEST PLUMBING & UTILITIES PLAN FIRST FLOOR EAST FIRE PROTECTION FIRST FLOOR WEST FIRE PROTECTION FIRST FLOOR EAST FIRE PROTECTION SPRINKLER SCHEDULE & NOTES HVAC SECTIONS HVAC DETAILS HVAC SECTIONS & MISC. TOILET ROOM PLANS & RISER DIAGRAMS PARTIAL PLANS, SECTIONS & DETAILS WORMALD FIRE SYSTEM, BLDG. 44, SHEET 1 HVAC PLAN FIRST FLOOR WEST DEMOLITION ELECTRICAL 1' oNLY RECEIVED CITY OF TUKWILA MAY 14 1991 PERMIT CENTER 7.33 -C1 7.33 -C2 7.33 -C3 7.33 -C4 7.33 -Al 7.33 -A1A 7.33 -A2 7.33 -•A3 7.33 -A4 7.33 -A5 7.33 -A8 7.33 -A7 7.33 -A7A 7.33 -A8 7.33 -A9 7.33 -A10 7.33 -A11 7.33 -Al2 7.33 -A13 7.33 -A14 7.33 -S1 7.33 -S2 7.33 -S3 7.33 -M1 7.33 -M2 7.33 -M3 7.33 -M4 7.33 -1M10 7.33 -1U1I 7.33 -1M12 7.33 -1M110 7.33 -1M111 7.33 -1M260 7.33 -1M261 7.33 -M262 7.33 -M500 7.33 -M501 7.33 -1502 7.33 -M503 7.33 -M504 REFERENCE DRAWING 7.33 -11!10 7.33 -El 7.33 -E4 7.33 -E6 7.33 -E7 7.33 -E8 7.33 -E9 7.33 -1E10 7.33 -1E11 7.33 -1E60 7.33 -1E61 7.33 -1E110 7.33 -1E111 7.33 -E500 1.33 -£501 7.33 -4502 7.33 -E503 .1•101••• /12•1110•121•PPINWIIIII - BE &C ENGINEERS B A A A G A B 8 8 F B E A B B B A A A A B 7-24-87 B 7 -24-87 B 7-24-87 A B 8 Q B B B B B A B B B B B 8 REV. DATE 05.08.91 7 -24 -87 6 -25 -87 6 -25 -87 6-25-87 I 05.08.91 7 -24 -87 7 -24 -87 7 -24 -87 7 -24 -87 05.08.91 7-24-87 05.08.91 7- 24-87 7 -24 -87 7 -24 -87 7 -24 -87 7 -24 -87 7 -24 -87 7 -24 -87 7 -24 -87 6 -25 -87 6 -25 -87 7 -24 -87 7 -24 -87 05.08.91 7 -24 -87 7 -24 -87 7 -24 -87 7 -24 -87 7 -24 -87 7 -24 -87 7 -24 -87 7 -24 -87 7 -24 -87 7 -24 -87 7 -24 -87 7 -24 -87 05.08.91 E 10 -25 -88 B 7 -24 -87 F 7 .2.d. &7 C 05.08.91 A 6 -25 -87 B 7 -24 -87 G 05.08.91 A 7-24 -87 1'r 05.08.91 A 7 -24 -87 B • 7 -24 -87 A 7 -24 -87 6 -25 -87 H 05.08.91 6 -25 -87 7 -24 -87 05.08.91 0 -J REVISION ISSUED FOR PERMIT 90% REVIEW ISSUED FOR CONSTRUCTION LOBBY RELOCATION BREAK ROOM ADDITION DATE SYM REVISION AUDIO ROOM SOUND CONTROL DUPLICATION CTR. ALTERATIONS RELOCATE A/C UNIT JOBS 91012-020 OFFICE ADDITIONS JOB S 91012 -062 BY APPROVED DATE FOA CC .26.9 RLT GC 1.2.9 PC GC FOA ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY FIRST FLOOR PLAN — WEST OFFICE ADDITION AlrINITTor 87059 F SYW .... ._._.. 111P.a�(AI� err ^. 11 t...Ims∎ka oa.i VV:I<ala1 1,4 6,. r..;,• . (. 131 UND 0 102SF UD10 CONTROL REFER SHEET A8 FOR FL SLAB ISOLATION SAWCUT AROUND RIr1S 141 & 142 LIBRARY SERVICES L 239SF ALIGN W/ EXISTING PARTITION VIDEO LIBRA 2410SF EXISTING ROOF ACCESS LADDER EXISTING PARTITIONS FLOOR TO ROOF STORAGE 1528) VIDEO DUBBING EEO SCHEDULING (�152A BUSINESS OFF -LINE OFFICE EDIT 1 2635F 93SF <106> <107> VIDEO VIEWING E X XTINGUISHER I N BE CABINET 548SF FIRE HOSE CABINET NSTALL OPERABLE WALL FLUSH / PARTITION WHEN STACKED FILM VIEWING ft 0o0 54asF SHIPPING 455SF --OPERA WALL CA MERA'OFFICES tz 692SF 71_5 / 11 . 14 1-8"4._7'.51/2 1 4 7' - 17'-9" 311 CONFERENCE tax 300SF VERIFY POCKET DIM W/ OPERABLE WALL REQM'1S 4' -0" _I Inl n� IIIII J1)111�I� ACHINE FF• -LINE EDIT 3 7 '93SF - 1A -0 ----L A V SEE MECH OFF -L EDIT 372SF VIDEO OFF] -Jl_ NE [.. F - LIN 4 DIT 5 L JAJ 93SF 113 CENTER PARTITIONS ON EXISTING STOREFRONT MULLIONS, TYP. OFF-LINE EDIT 6 fits 93SF M.> ELECTRICAL 1024SF 373SF PLASTER CYCLORAMA W A L L EQUIPMENT R 8 TO FACE OF VERT . STUDS 17 1_ 3 11 PROVIDE ME W/ 5/8" GW CLOSURE AT -- PROVIDE MET 5/8" GWB HO AT ELEV SIM 8'-0 "R TO FACE OF VERT. STUDS 93SF 1 Y 93SF OFF -LINE OFF -LINE EDIT 7 EDIT 8 Ltd r tII R STORAGE 104SF JOISTS W/ HOR I 1 9' -611 AFF JOISTS W/ I7 CLOSURE STUDIO CLG FILM EDIT 1 ail] 10SSF FILM EDIT 2 EEO 1055F 01200 ,,., BOOTH STUDIO Effl 2441SF 2' -8' FACE OF VERT. TO CONC. SLAB SAWCU PLASTER STUDS , TYP. - PRODUCTION CONTROL 2 314SF SOUND LOCK ART 714SF a. ®- 2r �,,.e.,>m.�®Jr1.. L.SJ VCT 11 11 COMPUTER ANIMATION o ANIMATION STUDIO FIRE HOSE CABI NET FIRE EXTINGUISHER IN CABINET EL �C T 1 -t A- -1A -0 -- MO OM SO -4 A- 4 OMEN 645SF 162SF YP `- SINFK, REF. I+ECH SET PREP C) REF ELECT FOR NEW METER ENCLOSURE PHOTO CELL ON EXTERIO WALL (22 -9 ") _ kIA— OFFICE Ioz 131SF Ci) (247 ") .� TYP. INFILL 17 //, 104 .; 11 _ - -.- -, •. - ii 11 ii ii _...11110=..M...r...... 0 i 8 "± EXIST 'G OP'G TO NEW DO ON'G 1/8 " =1' -O" (24'-7") 5� FIRST FLOOR PLAN — WEST (24'-7") PLAN NORTH r `' ' 4D7/7 �OG� /_G FACILITIES DEPARTMENT (24' -7 ") ❑ AUBURN, WA. 98002 ❑ BELLEVUE, WA. 98008 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 Si SEATTLE, WA. 98124 (24 ",ENTER PARTITIONS ON EXISTING STOREFRONT MULLIONS, TYP. INFILL AT STUDIO to t-- x 1"_", WEST PORT I ON I EAST POR ION (24'-r) .J C „ k 1- r fw L j�1 ICI III Iii Iii III III III 111 III III i I1 I ICI 111 III III 111 I� I(I III 1 11'1 1 TAIL III,III I�IIIIl I�111 ; 1111 IIIi1111111i1I11111�1I9i1111111i111i111 111 11111111111 III 1 1 1 1 � if1. 1 � 1 1 1 1 I I I C I II �i� Ali I I I �Ii i 1 i i � 0 16 THS INCH 1 2 3 4 5 6 7 8 9 10 11 WWEAJOEAMAKI 12 NOTE: If the microfilmed document is less clear than this notice, it is due to the quality of the original document. 0€ 6Z 8d LZ 9Z GZ bZ EZ ZZ lZ 0? 61 91 Ll 91 GL +11 El Z1 11 Q 6 9 L 9 G fi E 4 l ww 0 II!iI! iiiiiil�nl�i ��f iuh iii Iiii�iuliui�uiilni��iii� ,I�,!�I i��i�iii�h,�i��1i ! Iiii�li�i�iilii�,) �tIII�IIi, iilii�i�ni�lini�nul��i�Iii�il�nl�ii�il� ,ii_nnlinilit!!! ii ���11 �n,I! !rl►�n�i�!�I IHI�IIfI itiI�n 1 !III �I I i 1 1 I.!I ' ,I i 1 I 1 �� I�11�I���1M��1�1��, �� ► ►IIII�I�► ►��11����I�.II,�111I S111. REF. 12/A4 NO SCALE <16o> KEY PLAN FIRE EXTINGUISHER ON BRACKET 174 6. REMOVE LOW PARTI ION AND RETURN TO OWNER 7. PROVIDE AND INSTALL DOOR AND FRAME SEE SHEET A5 FOR HARDWARE SCHEDULE. 42' -7” PLAN NORTH 1i PLAN LEGEND MECHA G L 1404SF MECHANICAL ROOM PARTITIONS 5/8" TYPE "X GWB BOTH SIDES, TYP. REFER STRUCTURAL FOR CONC. EQUIPMENT PADS & BASES 112 REFER MECHANICAL & ELLECTRICAL FOR EQUIPMENT IN MECHANICAL ROOM MOTION PICTUME AND TV AREA BUILDING 7-33 GATEWAY BUILDING .4 L......J ROOM NUMBER, REF. SHEET A5 f1:::> DOOR NUMBER, REF. SHEET A5 A PARTITION TYPES, REF. SHEET A6 <� RELITE NUMBER, REF. SHEET A8 `°`° EXISTING CONCRETE WALLS AND COLUMNS METAL FRAMED PARTITIONS, FURRING AND INFILL NEW EXCEPT WHERE NOTED AS EXISTING EXISTING STEEL PIPE COLUMN NEW CMU INFILL a FLOOR DRAIN OR FLOOR SINK, REF. MECH. c -_7A OPEN PLAN OFFICE PARTITIONS, NIC c-•J MECHANICAL & ELECTRICAL EQUIPMENT, REF. MECHANICAL AND ELECTRICAL. 1 REFER TO SHEET A -lA FOR THE PORTION OF THE WORK EAST OF THE MATCH LINE. 2 DIMENSIONS SHOWN IN PARENTHESES () ARE EXISTING AND MUST BE VERIFIED. 3 DIMENSIONING IS AS FOLLOWS: TO EXISTING GRID LINES TO FACE OF EXISTING CONCRETE WALLS TO FACE OF STUDS 4. MECHANICAL AND ELECTRICAL EQUIPMENT AND FIXTURES SHOWN ARE PICTORAL ONLY, REFER MECHANICAL AND ELECTRICAL. FOR ACTUAL LOCATION AND CONSTRUCTION. 5 ROOM SQUARE FOOTAGES SHOWN ARE NET FLOOR AREAS FOR OCCUPANCY LOAD CALCULATIONS. DO NOT USE SQUARE FOOTAGES SHOWN FOR ONSTRUCTION QUANTITIES. RECEIVED CITY OF TuK VILA 11,41 1 4 1991 PERMIT CENTER PLAN NOTES 1 WEST PORTION I EAST PORTION Of w \ P P i` 0 \ I I LIE &c ENGINEERS DIG. ND. 7.33 -Al [1..... ROOM . ROOM FINISH SCHEDULE R1 FLOOR BASE MALLS CEILING REMARKS .. .. z —. '_i ► T'�;� 1 3;4'1 I 3/4'1 1 3/4`' %a •.ruru swa ; F HEAD 1 /A9 �i /A9 1/A9 �` � 8/A9 - 8/A9 7/A9 FIRE RATING _ _ - . GROUP 1 CLG H1 101 LIBRARY SERVICES F - 3 B -1 102 103 W -5 W -1 W -1 W -5 C -2 9' -O" . 102 IC OFFE M F -3 B -j 9/A9 W -5 • W -1 W -1 C -2 9' -0" 1 3/4'1, 1 3/41 13/4' 103 CORRIDOR -5 B -1 " - W -6 - W -5 W -1 III - W -1 - W -1 C -2 C -2 • C -2 9' -0" 9'• -0" A /A9 104 BUSINESS OFFICE _F F -3 B -1 1/A9 105 106 PRODUCERS F-3 B -1 9' -O" 109 OFF -LINE EDIT 1 F - 3 B -i W -1 W -1 W -1 W -1 W -1 W -I W -1 W -1 -- 11111 - 11111 - - • - - - - - - C -2 C -2 C -2 C -2 9'-0" 9' -0" 9' -L`" 1 3/4" ,: i 3/4 C A 1/A9 1 /A9 107 OFF -LINE EDIT 2 F -3 F - 3 _ B -1 B -1 108 OFF -LINE EDIT 3 9' -0" 112 109 OFF -LINE EDIT 4 F - 3 F-3 B -1 8 -1 C -2 C-2 C -2 C-2 9' -0" 9' -0" 9' -0" 6/A9 2_ 0 MIN 110 OFF -LINE EDIT 5 113 111 OFF -LINE EDIT 6 F - 3 F -3 F -3 B -1 B -1 B -1 1/A9 112 OFF -LINE EDIT 7 9' -0" 3____ -- 3 113 OFF -LINE EDIT 8 114 FILM EDIT 1 F -3 B -1 W -1 - • - 20 MIN C -2 9' -0" 1 ' -O" 115 FILM EDIT 2 F -3 B W -1 - - 116 C -2 9' -0" - - __-- 116 WORD PROC F -3 B -1 20 MIN - 117 3' -O" C-2 9' -0" A 117 OFFICE F -3 B -1 W-1 W -1 W -1 C - -2 9' -0" 1/A9 118 ART F -5 B -1 - _ 119 W -1 W -1 W -1 C -2 9' -0" 1/A9 1i9 CORRIDOR F -5 B -1 120 - - - - C -2 91_0" 6 /A9 120 LOBBY F -3 B -1 3' -0" -1, W -1 W -1 W -1 C -8 10: -0" ~12' - 121 VESTIBULE 122 B -4 - W -6 W-5 W -1 W -6 W -6 C -3 -0" TEMPORARY EXIT CORRIDOR -. 3' -6" B-1 C -2 9' -0" OFFICE PORTION OF BUILDING _. 20 MIN MEN F -6 B -2 7' -0" W -8 W-8 r W -8 C -7 9' -0" 125A VEST F -6 B -2 W -1 - - 3/A9 -- C7 g � -0 „ 126 WOMEN F -6 B -2 W -8 - - 4/A9 C -7 9' -0" 127 126A VEST F -6 B -2 W -1 2/A9 7/A9 20 MIN C -7 9' -0" 3' -0" 127 VIDEO LIBRARY F -1 B -1 - - 20 MIN 'C- 1/C3417' -0 °4: ON EXISTING ROOF 2X4 JOISTS 128 CORRIDOR F -5 B -1 W -1 - 20 MIN 20 130 C -3 9' 129 VIDEO VIEWING F -3 B• -1 W -1 22/A9 22/A9 W -11 C -2 11' -0" 132 130 FILM VIEWING F -3 B -1 W -1 21/A9 - _ W -11 C -2 11' -O" 3' -0" 131 CORRIDOR F -5 B -1 W -1 W -1 20 MIN 22 - C -3 [ 9' -0" 7' -0" 132 CONFERENCE 1/A9 B--1 - C -2 9' -0" 133 PROJECTION 7' -0" B -1 W -1 1/A9 1/A9 - - C-2 9 -0" 136 134 STORAGE F -1 F -5 B -I B -1 B -1 W -1 W -1 W -1 Ell -- - 6/A9 - - - - C -2 9' -O" 2' -10" C -3 C -3 9' -0" 9' -0" 1/A9 135 CORRIDOR 20 MIN 136 CORRIDOR F -5 137 ELECTRICAL F -1 B -1 W -1 1/A9 1 /A9 - - - C -2 9' -0" i /A9 138 STORAGE F -5 F -5 B -i B -1 W -1 W -1 - W -1 -- W -1 - - W -1 - - W-9 C -2 C -2 9' -0" 143 9' -0" 7' -0" 139 EQUIPMENT REPAIR C -5 8' -0 1/A9 140 SOUND LOCK F -2 B -6 141 AUDIO BOOTH F -2 8 -6 - W -1 W -1 W -9 W -9 C -5 8' -0 142 AUDIO PREVIEW F -2 B -6 A W -9 W -1 W -9 W-1 C -5 8' -O 143 144 AUDIO CONTROL PRODUCTION CONTROL 1 F -4 F -4 8 -6 B -1 - W -9 W -9 W -9 ': - - W -9 - - - ant W -9 Illaniffil -- C -5,C -' • 9' - -O" C -2 9' -0" ',SLOPED CEILING, 8' -0" 0 LO - 'HICTFPOJNT '# ' , 1O' -0" 0 7' -0" 145 TECHNICAL CONTROL F -4 F -4 B -1 B -1 146 PRODUCTION CONTROL 2 C -2 9' -0" 147 CORRIDOR F -5 B -1 W -1 2/A9 2/A9 6/A9 20 MIN C -3 9' -0" 148 COMPUTER ANIMATION F -4 B -i W -1 1 /A9 1 /A9 • 6/A9 - C -2 9' -0" 149 ANIMATION STUDIO F -5 B -1 W -.1 - 1 /A9 6/A9 - C1 /C3* 17' -O "_ ON EXISTING ROOF 2X4 JOISTS 150 ELECTRICAL F -1 B -1 p -1 1/A9 1/A9 -- - C -3 9' -0" 151 ELECTRICAL - - -- 1/A9 1 /A9 - - - 17' -0 "_ EXIST. RM, NO FINISH WORK 152 VIDEO DUBBING F -1 B -1 - 24/A9 24/A9 -• C1 /C3* 17' -0 "T * ON EXISTING ROOF 2X4 JOISTS 153 CAMERA OFFICES F -3 B--1 W -I 1/A9 1/A9 - - C -2 9'-0" 154 SHIPPING F - i B - I W -1 1/A9 1 /A9 6/A9 20 MIN C -I 17'--0 "± 155 M MACHINE F -3 8 -1 W -1 1/A9 1/A9 6 /A9s11, - C -3 8' -O" 156 FILM LOAD 1 F -i D -1 W -I 1/A9 1/A9 - 20 MIN 8' 157 FILM LOAD 2 F -i B -1 W -1 1 /A9 1/A9 - 20 MIN C -3 8' -0" 158 PHOTO EQUIPMENT F -1 B -1 W -1 13/A10 •- - - C -1 I7"- 1 __ 159 VIDEO OFFICES . F -3 B -1 W -1 2/A9 - - - C -3 9' -0" M 160 STUDIO F -2 B3/85 - W--1 - W -1 - W -13 - - - - 15 C -4* :5' -6 "_ C -2 9' -0' # � COU5TIC WITH EXPOSED LIGHTING GRID 7110 FOR MATERIAL 161 CORRIDOR F -5 F -5 B -1 8 -1 162 SOUND LOCK C -2 9 -0 " A.LTACHUF 1T DETAIL 163 SET PREP F -1 B -1 W -1 B - - - C -1 17' -O '_ 164 MECHANICAL F -1 B -1 - 1 3/4" 1 3/4 1 3/4" W -1 W -10 18/A9 1/A9 1/A9 C -i 17' -0" - 165 UNOCCUPIED F -1 - - W -I0 W -10 W -I0 ' C -1 17' -O" 1 3/4" A 1/A9 1 /A9 - - 17 168 2' -6" 1' -0" _ A 1/A9 i /A9 - - 17 169 170 6' -O" 7 ' -0" 1 3/4" H 12/A9 12/A9 13/A9 - S 18 3' -0" 7 ' -O" • 1 3/4" F35 25/A9 25/A9 - 10/6/87 5741 1 90% REVIEW A ISSUED FOR CONSTRUCTION B LOBBY RELOCATION BREKE RM ADDITION REVISION APPROVED DUPLICATION CTR. JOB S 90244 OFFICE ADDITION JOB S 91012-062 REVISION FACILITIES DEPARTMENT D AUBURN, WA. 98002 D BELLEVUE, WA. 98008 D EVERETT, WA. 98201 O KENT, +A. 98031 O PORTLAND, OR. 97220 O RENT ON, WA. 98055 • SEATTLE, WA. 98124 HARDWARE SCHEDULE DOOR 140 1 1/2 PR. HINGES HA I EA LOCKSET YA 1 EA KICKPLATE BW 1 EA WALLSTOP BW ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY BB1279 26D 10A MOR8701 CLS 10B 37 10'X2" LOW IOB WC 9T 10 DEPT. ENGINEERS DWG. NO. 7.33 -A5 SINK RELOCATION DATE A D FLOORS Fl EXPOSED EXISTING CONCRETE SLAB, SEALED F2 EXISTING CONCRETE SLAB, LEVELED & PATCHED, SEALED F3 CARPET F4 ANTI - STATIC CARPET F5 VINYL COMPOSITION TILE F6 CERAMIC TILE F7 ENTRY MAT BASE 81 4" RUBBER BASE B2 COVED CERAMIC TILE BASE B3 PLASTER CYCLORAMA BASE B4 ALUMINUM BASE SIMILAR TO STOREFRONT FRAME B5 1X6 WOOD BASE 86 6" RUBBER BASE WALLS W1 NEW GYPSUM WALLBOARD, PAINTED W2 NEW GYPSUM WALLBOARD, UNPAINTED W3 EXISTING GYPSUM WALLBOARD, PAINTED W4 EXISTING GYPSUM WALLBOARD, UNPAINTED W5 EXISTING STOREFRONT, FACTORY FINISHED, WITH NEW GYPSUM WALLBOARD ABOVE, PAINTED W6 NEW STOREFRONT, FACTORY FINISHED, WITH NEW GYPSUM WALLBOARD ABOVE, PAINTED W/ PLASTER CYCLORAMA WALL W8 CERAMIC TILE OVER CEUENTITIOUS BOARD W9 NEW GYPSUM WALLBOARD, PAINTED, WITH ACOUSTIC PANELS OVER W10 EXPOSED EXISTING STRUCTURE, UNFINISHED W11 NEW GYPSUM WALLBOARD, PRIMED, WITH VINYL WALL COVERING W12 OPERABLE WALL WITH VINYL WALL COVERING W13 NEW GYPSUM WALLBOARD, PRIMED, WITH ACOUSTIC MATERIALS OVER, WITH HARDWARE CLOTH WAINSCOT. CEILINGS C1 EXPOSED EXISTING STRUCTURE, UNFINISHED C2 STANDARD SUSPENDED LAY -IN ACOUSTIC CEILING TILES, 24 "X48" C3 GYPSUM WALLBOARD, PAINTED C4 GYPSUM WALLBOARD, PRIMED, WITH ACOUSTIC MATERIALS OVER C5 SUSPENDED LAY -IN GLASS FIBER ACOUSTIC TILES, 24 "X24" C6 SUSPENDED LAY -IN 5/8" PAINTED GYPSUM WALLBOARD TILES, 24 "X24" C7 GYPSUM WALLBOARD, WITH ADHERED 12 "X12" ACOUSTIC TILES OVER C8 LOBBY SUSPENDED LAY -IN ACOUSTIC CEILING TILE, 24" X 24" GRID, TEGULAR EDGE TILES 0 167NSINf" ., 2 3 PRE -FIN LIGHT GAGE HM. FRAME SOLID CORE OAK VENEER WOOD DOOR STOREFRONT DOOR T O MATCH EXIST. STOREFRONT WINDOW EXISTING HM DOOR & FRAME FINISH LEGEND B E H EXISTING SECTIONAL 0.H. DOOR DOOR TYPES WIRE GLASS LITES PRE-F64 LIGHT GAGE HM. FRAME PAIR SOLID CORE OAK VENEER WOOD DOOR PAIR STOREFRONT DOORS TO MATCH EXIST. STOREFRONT WINDOWS HM FRAME PAIR HM DOORS C ACOUSTICAL DOOR & FRAME F88 : APPROX. STC : 35 F4S : APPROX. S'TC : 42 NEW INSULATED SECTIONAL O.H DOOR 1 I 1 1 1 1 1 1 1 1 1 1! I I 'I ': f! I :. ter.- ,F, ;.;,�:: I I! I I I 1 I i 1 i l l 1 1 1 1 1 111 III 1 1 1 1 1 II1 1 1 1 1 1 IIIIIIIIIIIIIIIIIIIIIIIIjIIII 1 1 1 1 1 1111111 , , 1 1 1 1 1 1 1 1 11111111111111111111111111 4 5 6 7 8 9 10 11 ►,. l•, Ea►Wn 12 NOTE: If the microfilmed document is less clear than this notice, it is due to the quality of the original document. oc 6Z 8G LZ 9Z SZ VZ CZ ZZ Lz OZ 6t Sl Lt 9t St Vt Ct Zl « OI. 6 8 1,. 9 S C Z l riW 0 I iiiIill!!!l ill i!!iInnln liIiii►h iiIiiiit iii�iilillli ! �iii ili!11��! !,Ir!! !!!ill�i!�n! !!, J ul iiilliiiilli! i�! niL iii�!!! I I� ii i�iii !1 �n11i11111�11liililuliIiiiii ! Iil! it !li ilifuu�liil!!►ii�iiilliii�in lli!iiiiiii i� ►I a �� - ......::, , .; .. _ _ ! ,,. LI!II) ��. Ill�ll. ill► II (I,1111.1lIII.Il��IIIIIIIlIIl11 RECEIVED CITY OF Ti1KWILA HAY 1 4 19gi PERMITCENTER FINISH & DOOR SCHEDULES T TIE MOTION PICTURE AND TV AREA BUILDING 7-83 GATEWAY BUILDING #4 J OFFICE F ADDITION . . , C i .4 %lrr• 1 •; <''3 i T`� V': A A A.. DOOR SCHEDULE r_ DOOR MO. 101 WI1�T i 3'-0" .rr¢ IIEI6h= 7' -0" .. .. z —. '_i ► T'�;� 1 3;4'1 I 3/4'1 1 3/4`' %a •.ruru swa ; F HEAD 1 /A9 �i /A9 1/A9 �` � 8/A9 - 8/A9 7/A9 FIRE RATING _ _ - . GROUP 1 REMARKS JAMB 1/A9 1/A9 1/A9 2 3 - 102 103 3' -O" 3' -0" 7' -0" 7' -O" 20 MIN 104 3' -O" 7' -O" - 1 r) 3 /A9 3/A9 9/A9 - 12 105 106 3' -O" 3' -0" 7' -0" 7' -0" 1 3/4'1, 1 3/41 13/4' A A 1/A9 1/A9 1/A9 1/A9 1/A9 6/A9 a20 _6/A9 6/A9 MIN 20 MIN 20 MIN 3 7 _ -- 3 --- 3 107_ 108 3' -O" ' 7' -0" A /A9 3' -O" 7 '-O" 1 3/4" A 1/A9 1 /A9 6/A9 6 /A9 20 MIN 20 MIN 3 7 J - ___ 109 3' -0" 7' -0" 1 3/4" A 1 /A9 1/A9 110 111 6' -0" ' -" 3 0 7' -O': 7 1 3/4" ,: i 3/4 C A 1/A9 1 /A9 1/A9 1/A9 7 /A9 6/A9 — 20 MIN 6 20 MIN 3 112 3'- -0" 7' -O" 1 3/4" A 1/A9 1 /A9 6/A9 2_ 0 MIN 3 113 3' -0" 7' -O" 1 3/4" A 1/A9 1/A9 6/A9 20 MIN 3____ -- 3 114 3' -O" 7' -O" I 3/4" A 1 /A9 1 /A9 6/A9 20 MIN 115 6' -O" 1 ' -O" 1 3/4" B 2/A9 2 /A9 6/A9 20 MIN 8 116 • 3' -0" 7' -0" 1 3/4" A 2/A9 2/A9 6/A9 20 MIN 117 3' -O" 7' -0" 1 3/4" A 1/A9 1/A9 6/A9 20 M]-t-4 118 3' -0" 7' -O" 1 3/4' A 1/A9 1/A9 6/A9 20 MIN - _ 119 3' -0" 7' -0" I 3/4" A 1 /A9 1/A9 6/A9 20 MIN 120 3' -O" 7 ' -O" 1 3/4" A 1/A9 1/A9 6 /A9 20 M]N 121 3' -0" 7' -O" A 1 /A9 1/A9 - - 122 3' -0" 7' -O" 1 3/4" A 1/A9 1/A9 6 /A9 20 MIN 123 3' -6" 1' -O" 1 3/4" A 1 /A9 1/A9 6 /A9 20 MIN 124 3' -0" 7' -0" 1 3/4" A 1/A9 1/A9 - 125 6' -0" 7' -O" - E 3/A9 3/A9 5/A9 - 126 6'-0" P-0" • - E 3/A9 3/A9 4/A9 127 3'-0" 7'-0" 1 3/4' A 2/A9 2/A9 7/A9 20 MIN 128 3' -0" 7' -0" 1 3/4" A 2/A9 2 /AQ - 20 MIN 129 3' -0" 7' -0" 1 3/4" 1 3/4" A _ F35 1/A9 20/A9 1/A9 20/A9 6 /A9sly - 20 MIN 20 130 3' -0" 7' -0" 131 3' -0" 7' -0" 1 3/4" F35 22/A9 22/A9 - 21 132 3' -0" 7' -0" 1 3/4" F35 21/A9 21/A9 - _ 21 133 3' -0" 7' -0" 3 1/4" F42 23/A9 23/A9 20 MIN 22 134 3' -0" 7' -0" I 3/4" A 1/A9 1/A9 - 2 135 3' -C" 7' -0" 1 3/4" A 1/A9 1/A9 - 3 136 3' -0" 7' -0" 1 3/4" 1 /A9 1/A9 6/A9 20 MIN 3 137 2' -10" 7' -0" 1 3/4" 1/A9 1/A9 10/A9 20 MIN 3 138 2' -10" 7' -0" 7 7'-0" i 3/4" 1/A9 1/A9 1 /A9 10/A9 - 20 MIN 3 . 0" 3 0 6'-0" i /A9 .. 13 1 40 . 142 B 4 SEE HDWR SCHD. THIS SHEET 2/A9 2/A9 143 3' -0" 7' -0" 1 3/4" A 1 /A9 1/A9 7/A9 20 MIN 10 144 6' -O" 7' -0" 1 3/4" B i /A9 1/A9 6/A9 20 MIN 8 145 3' -6" 7' -0" A 2/A9 2/A9 6 /A9 20 MIN 11 146 3' -0" 7' -O" 1 3/4" A 1 /A9 1/A9 6/A9 20 MIN 3 147 3' -0" 7' -0" 1 3/4 "' A 1 /A9 1 /A9 7/A9 20 MIN 3 148 3' -0" 7' -0" 1 3/4" A 2/A9 2/A9 6/A9 20 MIN 3 149 3' -6" 7' -O" 13/4" A 1 /A9 1 /A9 • 6/A9 20 MIN 3 150 3' -O" 7' -O" 1 3/4" A 1/A9 1 /A9 6/A9 20 MIN 3 151 - 3' -O" 7' -O" 1 3/4" A 1/A9 1/A9 -- - 1 152 3' -6" 7' -0" 1 3/4" A 1/A9 1 /A9 •- - 11 153 3' -O" 7' -0" 3 1/4" F42 24/A9 24/A9 -• 22 154 3' -O" 7' -O" 1 3/4" A 1/A9 1/A9 - - 1 155 3' -0" 7' -0" 1 3/4" A 1/A9 1 /A9 6/A9 20 MIN 3 156 3' -0" 7' -0" A 1/A9 1/A9 6 /A9s11, - 2 157 6' -0" 1' -0" 1 3/4" B 1/A9 1/A9 - 20 MIN 14 158 5' -8" 7' -O" 1 3/4" B 1 /A9 1/A9 - 20 MIN 23 159 5 7' -O" 1 3/4" H 13/A10 3,14/A1 + - - 24 160 3' -O" 7' -O" 1 3/4" A 2/A9 2/A9 - 1 -HR _ 7 161 3' -0" 7' -O" 1 3/4" G - - - - 15 EXISTING DOOR 162 3' -0" 7' -0" 1 3/4" G 11 /A9 I1 /A9 - - 15 EXISTING DOOR 163 6'--O" 3' -0" 1 3/4" B 2/A9 2/A9 - __ - 13 164 165 166 9' O - " 3 0 3'--6" 10�' -O' 7 -0 7' -0" 1 3/4" 1 3/4 1 3/4" 1 A A - 1/A9 1/A9 18/A9 1/A9 1/A9 16 - EXISTING DOOR, ELEV. 19/49 - - - 1 1 167 2' -6" 7' -0" 1 3/4" A 1/A9 1 /A9 - - 17 168 2' -6" 1' -0" 1 3/4 A 1/A9 i /A9 - - 17 169 170 6' -O" 7 ' -0" 1 3/4" H 12/A9 12/A9 13/A9 - S 18 3' -0" 7 ' -O" • 1 3/4" F35 25/A9 25/A9 - 25 _ 171 9' -O" 10' -0" - J 14/A9 14/A9 - - 16 FRAME ELEVATION 15/A9 172 9' -D" 10' -0" - J 16/A9 16/A9 - - 16 mu FRAME OEREVATJQNSTINC OPENING 173 3 7' -0" - G 11/A9 11/A9 - - 19 EXISTING DOOR 174 10' -O° 12' -O" - I I - - - - 16 EXISTING DOOR 175 3' -O" 7' -O" - G - - - - 15 EXISTING DOOR 10/6/87 5741 1 90% REVIEW A ISSUED FOR CONSTRUCTION B LOBBY RELOCATION BREKE RM ADDITION REVISION APPROVED DUPLICATION CTR. JOB S 90244 OFFICE ADDITION JOB S 91012-062 REVISION FACILITIES DEPARTMENT D AUBURN, WA. 98002 D BELLEVUE, WA. 98008 D EVERETT, WA. 98201 O KENT, +A. 98031 O PORTLAND, OR. 97220 O RENT ON, WA. 98055 • SEATTLE, WA. 98124 HARDWARE SCHEDULE DOOR 140 1 1/2 PR. HINGES HA I EA LOCKSET YA 1 EA KICKPLATE BW 1 EA WALLSTOP BW ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY BB1279 26D 10A MOR8701 CLS 10B 37 10'X2" LOW IOB WC 9T 10 DEPT. ENGINEERS DWG. NO. 7.33 -A5 SINK RELOCATION DATE A D FLOORS Fl EXPOSED EXISTING CONCRETE SLAB, SEALED F2 EXISTING CONCRETE SLAB, LEVELED & PATCHED, SEALED F3 CARPET F4 ANTI - STATIC CARPET F5 VINYL COMPOSITION TILE F6 CERAMIC TILE F7 ENTRY MAT BASE 81 4" RUBBER BASE B2 COVED CERAMIC TILE BASE B3 PLASTER CYCLORAMA BASE B4 ALUMINUM BASE SIMILAR TO STOREFRONT FRAME B5 1X6 WOOD BASE 86 6" RUBBER BASE WALLS W1 NEW GYPSUM WALLBOARD, PAINTED W2 NEW GYPSUM WALLBOARD, UNPAINTED W3 EXISTING GYPSUM WALLBOARD, PAINTED W4 EXISTING GYPSUM WALLBOARD, UNPAINTED W5 EXISTING STOREFRONT, FACTORY FINISHED, WITH NEW GYPSUM WALLBOARD ABOVE, PAINTED W6 NEW STOREFRONT, FACTORY FINISHED, WITH NEW GYPSUM WALLBOARD ABOVE, PAINTED W/ PLASTER CYCLORAMA WALL W8 CERAMIC TILE OVER CEUENTITIOUS BOARD W9 NEW GYPSUM WALLBOARD, PAINTED, WITH ACOUSTIC PANELS OVER W10 EXPOSED EXISTING STRUCTURE, UNFINISHED W11 NEW GYPSUM WALLBOARD, PRIMED, WITH VINYL WALL COVERING W12 OPERABLE WALL WITH VINYL WALL COVERING W13 NEW GYPSUM WALLBOARD, PRIMED, WITH ACOUSTIC MATERIALS OVER, WITH HARDWARE CLOTH WAINSCOT. CEILINGS C1 EXPOSED EXISTING STRUCTURE, UNFINISHED C2 STANDARD SUSPENDED LAY -IN ACOUSTIC CEILING TILES, 24 "X48" C3 GYPSUM WALLBOARD, PAINTED C4 GYPSUM WALLBOARD, PRIMED, WITH ACOUSTIC MATERIALS OVER C5 SUSPENDED LAY -IN GLASS FIBER ACOUSTIC TILES, 24 "X24" C6 SUSPENDED LAY -IN 5/8" PAINTED GYPSUM WALLBOARD TILES, 24 "X24" C7 GYPSUM WALLBOARD, WITH ADHERED 12 "X12" ACOUSTIC TILES OVER C8 LOBBY SUSPENDED LAY -IN ACOUSTIC CEILING TILE, 24" X 24" GRID, TEGULAR EDGE TILES 0 167NSINf" ., 2 3 PRE -FIN LIGHT GAGE HM. FRAME SOLID CORE OAK VENEER WOOD DOOR STOREFRONT DOOR T O MATCH EXIST. STOREFRONT WINDOW EXISTING HM DOOR & FRAME FINISH LEGEND B E H EXISTING SECTIONAL 0.H. DOOR DOOR TYPES WIRE GLASS LITES PRE-F64 LIGHT GAGE HM. FRAME PAIR SOLID CORE OAK VENEER WOOD DOOR PAIR STOREFRONT DOORS TO MATCH EXIST. STOREFRONT WINDOWS HM FRAME PAIR HM DOORS C ACOUSTICAL DOOR & FRAME F88 : APPROX. STC : 35 F4S : APPROX. S'TC : 42 NEW INSULATED SECTIONAL O.H DOOR 1 I 1 1 1 1 1 1 1 1 1 1! I I 'I ': f! I :. ter.- ,F, ;.;,�:: I I! I I I 1 I i 1 i l l 1 1 1 1 1 111 III 1 1 1 1 1 II1 1 1 1 1 1 IIIIIIIIIIIIIIIIIIIIIIIIjIIII 1 1 1 1 1 1111111 , , 1 1 1 1 1 1 1 1 11111111111111111111111111 4 5 6 7 8 9 10 11 ►,. l•, Ea►Wn 12 NOTE: If the microfilmed document is less clear than this notice, it is due to the quality of the original document. oc 6Z 8G LZ 9Z SZ VZ CZ ZZ Lz OZ 6t Sl Lt 9t St Vt Ct Zl « OI. 6 8 1,. 9 S C Z l riW 0 I iiiIill!!!l ill i!!iInnln liIiii►h iiIiiiit iii�iilillli ! �iii ili!11��! !,Ir!! !!!ill�i!�n! !!, J ul iiilliiiilli! i�! niL iii�!!! I I� ii i�iii !1 �n11i11111�11liililuliIiiiii ! Iil! it !li ilifuu�liil!!►ii�iiilliii�in lli!iiiiiii i� ►I a �� - ......::, , .; .. _ _ ! ,,. LI!II) ��. Ill�ll. ill► II (I,1111.1lIII.Il��IIIIIIIlIIl11 RECEIVED CITY OF Ti1KWILA HAY 1 4 19gi PERMITCENTER FINISH & DOOR SCHEDULES T TIE MOTION PICTURE AND TV AREA BUILDING 7-83 GATEWAY BUILDING #4 J OFFICE F ADDITION `) 4',10 ON DM0 I ' 2Ls anions 03AOI ddY zI0!.6 ,# OOP VOA ONIMAI 33N3}3 42Wti d - r1LI "°2N da27a4 1r ..� c/: a /- 17 NOI51A31d 03A0!!+!d!* A8 N O LI.OnYuc Mo Na: &a t m, i / \3zt °b oreD h 1.1.VV 7''1 144301 I66!ft 1 w V1iN1)if11 10 AID 4 >; , ` t v a9A133EH e 14e //s& , c3Vvt-,1 lV�i'dl c:1r )1d st •7NO +1�' - 7Iv 1.1-t i'1 4 "))<, ;,N , h�IC7t1l t2'Vd 3ThL L9 •$'6 °J 03AO1:1ddd SI NOI1V313133dS MOI0NY NDIS30 Still ,Rll •.: �::. 333K (D`� 1 OE 'aH ' A UMUM4111ifiu�i11Yy11 UiiuuU MYrI iiiiar 11Yssuvum • "11 HQ LLD NOLLI °1'dt- iailtG.!G'd �tO c .v 1 cW 1 01 t tZt-86 ''VM .'31iIV3S g9096 ''VM 'NO1N38 ❑ OZZL6 '80 'ONV 11i1Od 0 LCO86 'VM 'IN3! ❑ L OZ86 'VM '1131#3/ 3 ❑ ZOO86 'VM 'N8fl8r1V ❑ 1N3INJUVd3a S3I111I3Vd arAiltzWir 110 UUY Win/AM ' 1.1.01021.110.11.114U NOir ,Aatl tem 'A $Y slob ON* a • '11�71..3U: C.t ON tom' x3 4 9‘116.1 't"ti cr1 k/t- 112r1 -7 1N07 �t3"111 7 NO :1vIGIM- rl ter1 - ugA4 tm G I r Q d l ItitOI i1- 11.4'.1 ~In�F�tl .L» '4 GE 1`J(1C �Z / '7 �Gtn�G✓ "4 ? or'i x cl2tIl 'NO CidIvW),,Q s GI a'1r1G1:J't-t 7o cy Hc; i Nld "r N\ Zvi 'IdS,L •W1g '710 t- eoth1 Ava No - ei e arek rs- SH,Nt. C,J.gtO- 1- t3SNtt3eci �7NG17C)`Kd C0* VZ. 4? tom 57 waspish% o-,t nee- .98 0 . 116- ,6OL 'cot 1 -t1Gz1 •1fl 4 1.1'44 c�Nnc> u T� c��G IG 1-ticx� dl,i ( ?'O „mil GeAnic OZ x u r 4t y NU e-tzmiCed crtoil1 NO 3"1!1 ',1b- IV'?1t37 --)o '1 z ail 'ccu�1� �o c1 Cy ziar'INn 1NCX7 01 '7'O 1P Z g 9 ctLL • 1c :N I U1--10C, 6134., - ► 'e7"17 1no at Inn c',0 ( i1 01 - I t' 131"1 - ''dam crb )„J- (9dTe/cy t' 1491 • d .'t1- t CI3tcln.Z)h it ��I I II I lIl�!I!!!I;nl!I 0 MM 1 Z1 nNvwat„N,aam I, I, 111111111111111i11111 71 .1 -\.i1. 41Mt 11 „ � L c 1A ei ict - e.I C't1OI.L i1N3Lv.3'.7 ?t AO Si 11 711.. d i3V t.0 Cd M9 .,X 11 1,1- 11 TI'Z'* .70 „t v c�rJni4; 131.AA ''4'7 OL x�,e /y� 44MA 11X11 aeU-1- *NI 11 d G1N()3 qJ /+C HcxJ 1 —1IQL •h,7 I f zaAO 3111 7�Id.'1H� NG� Ge31.ON "a2'I :t v?N171 i;1 C ■11' c; , .v' 31v • 1 H; -`v1a W 't71D •C7 r�Sut H.lcxd Cs4N 11) t Q 1 )17 ;1 1'vN\ "v cr)'ZiF4 -i ” " QQL -` 4 w 11 17Ti e c .L 310.E :LG I/4 `9'9 43 S X , 1 '� c G1n.1c 1 A.L'3Ce! 1)1- 117r)o 4.1 NO ir) 0 7 „Y, SeJ,J1L fdlM�) 11% _'+re 11'1NO SdhL 4CK3 1: 01. _E?t-11'74 5 "1.71.4 7's/tJ bb) o7, X 1 .2 /Gt'r�,. U`v�H c3'v'1°" t� O 11:73'1 �3C1 II I! II�I .I ;lllllnu;!!!iI!!lil!I!iluu;!I I Assorammo sztaHm / \i)tdkl.a adt,.L 7 111 , 4n) e 9*_ i) — ediA9 a nd /c, � OOe'i " 'O qtYtS cp 07/1 (Q) / >t ' .. 1dam'`1) Ci.LIOZ =1002:5 Nab NA,1 N17170143 1 1x;©17 -tt N\' N 411 or ,rsayr .s7 •rwwugs�we.•. rre . ; �I ;,I . IIiII; Ii llllll IIIIil; IUI�IiII ;{IIII1111;11III!!II;II! 111111;; LI�IIII; I1IIlilIl ;lIJI1111;IulI!I,I�ullf ll1!; 11111!! II; lIIIII IIIIIIIIi ;IIIIIIIII;ill,llilll!IIIII 1;11111 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 98 29 30 Q” •Wamn3op Te1T2T10 0113 Jo AMenb atl: ctaLQN cam' l .4 cV /Z. •� 1rr't: - 0 1 *iC ::KDO •p' v2,1. �d 'Vv14� ��`9V -r! v7 -,7 13.1.v'i8 °t"IVN\ 'a1 01710 �l 1G,\y'1 1 �C,G1C'lt5 ?taLL\rd „U Z �tio I °1"NL�'c/ cat1 37v..*1 lot-4 co j 4NOI1tlzl' ode; 11 I .1x/41 or-knor; :Lon�i15 ��2t I ':Yc ji 7 S Un1'.; - ,, 191^1 • I F') m 6gAO 1,1'91/4 1■1tWd21O V ( 1t - tf1o5 . . 11 2 / 441Me' „rd/, (4) t7Ni?:12:O 4c-,o t7 ' e )'1J $XZ t I'd ' 251` Lt-'it'lam G Utzt") hrt11. QICICIL� . �� :l0(ret.L Aar `141ar. 7`17 oiGnLG -_ - -_�- ) � d 4 7N1 ~•7o - tc-d hr.11,1'7014d ON d00?1 'r,1C,IX C) C1.1 -'1 1.1`'1Q . st NYV OZ " „a — "1C7GItzl'atC72 11,101-4 (� 1dS7)G q _"a,a11.1 1 tom. :No1.Lc n L NOJ ! G`dat °) v 1- 401,0 1A3Gt 3 1 x t1 I 01 siq� ueto 1e0T3 1390T ST: 31104013 0P pamTT3o1ZTm aila 31 : LION 6 6 9 G 9 C z 0 I 1 a H�NI SHl 9t `.I•� iIIIIII <I 111 11111 1III 11111111 1111111I11111111111 111111_ II11111111111111111111I11 !1111111!11IIiIIIIIt ri. 1111111! I111I1111111I1111111111111111111111 , -�. �v i ✓ i' , . 6 � - i b ..�'., .` . e y�, u.w r„ J;�.� J 1!:Z 1 - .:. • �� � �. �nY �' �`]L'. �. :iyJ T'r ..fir- .:-P .- .x. >.m • . 11 °0 : ,1 11 ► 2 r C,AV H NO 11 21 1 :I j 4 0 -,1 11Q /,C. c c r..1 tNioi .L I 1 • -ad .............................. • n .'�1. 1� -T'Tt 11111• , enp sx 3T 'eactou 'ut'1 '1:19 .t:A aC1 C2t H ' LI " ION od onIG 11� 'N►t� `7.47dau. 'rr1 d33rt •S 0)I -A0c)1, c1t ixa ,' \--1 01.1.11-6 i t-tt Jrn NO ri1 (Yti`�7 ttiOi1I12tvcl aztn o ?. 4Jf fit-? it HC)il.1123'dd ��f\o y 717 1 71 d rdY1 , 'Nit'4 • G4 c: aL. - Nt -ire1, Gnt� 'n1 i 'N11/1 �1 ty oNc; l,tv'd N4 1/ A 4oQ6 at_ c1`+oW1ze,' 3 1°1�1�N 1ON QC-1 :SIGN 01 t7 Cl�rdC1 ni f�I LL*d•1f7Gihil 111''4 • Qt- ocx 1 ,7�/$ 7i: - a13 618n cu. (;13(..11C, t- tl cxd el t'\t7 1 f � O t1-b•Z boo a1. • 1t-to OC (:7 'vl7 OZ, x u' -rte fi Sl7'1: �unl� 4- 43M13cd �')N►7l'7O1�d . 7c7 110 - - a3 in^ k; 1117 • f �?9'I�_I u t, T9T ttio 117 '13aGi 1 Lifaist ?.1QGlzizloJ Gg is 11 .1.041 t'ciM� „ )<,1 1L g / c am GtC"li: 1.SW7 ' e ) . < -_ Zl?l07 / CI v'°e t IL 'Tt V. LiV H NOLL7 1JCi r aria i 1 QL td/s ,1t2/r-+' '1 C: :a �" t 11r1C7J �\7zl4� 1rto.7 rI 11 11x '11 a v)91. dam-,? 4= M 1= -toll %,1; `std' 1 ' ILI'�101 Q • . ):•O c4r C70 - . Z "' HOLI,U2:1Vd 1 .0'17.41MCra _7 -sN : 17N17:os 3G1� t-11o41 41.1 7'o N bZ c G ant. 1.3W• 4Z f cat t 1Yn 91 r • 2i 21OJ na1QN .`Q` 1- -401,1:00M1GNO'D '70 ,R'j -,``7 'e7 :1.' ),1 A00 Q. t- •117V7J4.1 T('9N: ►r1 d JNI 1 . 7 0 iJ rv �KL►* . `VI 34.-1 'NI 'aiG✓NO7 ctQL: l`- vj .. kl 1O W. 3600_ -''—' 0 0 - 1 1 uZit, 400161 21, - 611/A wirg VT 1 960\1 rzIAOD -Avv.1 070 . Pa rn SYR REVISION BY APPROVED DATE REVISION BY APPROVED DATE 1 ISSUED FOR PERMIT ADS + 5/27/87 F.T. , . 1 RELOCATE A / C UNIT JOB ii 91O12-O20 ADS 11=11 90% REVIEW ADS .6/12/87 OFFICE ADDITION JOB t 91012 -O62 FOA t — 5.08.91 ISSUE FOR CONSTRUCTION ADS 6/25/87 B LOBBY REIOCATIQN ADS 7 /24 /81 DUPLICATION CT R . JOB 190244 RL T cc 7/24/90 LOW CLGS. , PP EXPOSED ST TU CEILING CO ABO frur ■1 � ■1iLIlI ■ ■ ■ ■ ■� I 1 U . 1 1 11 4000 - _ 1►r ��l�fi I�IMnIa•_..� iw.l�t�1.� - --- 4= . 101.rr >ii:■w. ,...... i% I��1■ I�I1: I�fMIII�I�I�I�I�I* I� /i�I li�l!llf . 11111±11 M 011.11111P ! I:I 1 1. 1 11111 tri 7-T+i •� , IA fil � � � • ► a.. taua .i � � ►�,� _� t.!:�t• nl.r' 11111111 Ili II I 111111 !�1 10111111 411 Pill I :I111,M111 iiM � ■ �I �■ III M I .�.: {. ., l rl�l�i:. 11 111 1, _ IJ� ■� I I rl.� I..II wA yid� I . 1 I — I !i' �� _ #1 _ :I fil l :`r`I IiJ.ID' 1 E t. 0'4 ., 41 Ina im flI1 ���IIEi� 11�I N.ms it a l■ ammo ano m ll. mu mmini I ��I�t �1 1� *I�� ` I rM.rr��,��. r . ..nr r.r J�+n i r.w�lll � *iawiiw . otowlimowi �u I I111 III ■II111.�ialu.: l y � • t � �� � -� _ : II . _- "�� ���� ��. !��II�� ■11;x. R1.III;.I� , I , -"' _ ,r; (► �- i . `� IiI ❑III• •yttl�lJI Mf/1- . I1 ,1.: � ,�IlC�,lll ■II,Ij.IiEt..�,, _ .__ .. Yt............ rtiwi '" ltI11 I /I�IUI tiliMtlti* JUI I>•1R11111•U �F :a ilia dINII`Il$.NIUI■l slur I�MtR ui•i 01110.1* lw11111111111 1 , - _l ■JM1�1 1�1 ►'�1 1 ■1��1(I rI IAI IK111 1I. r Sri IIi*rl 1i_ 1 1.1 I .. . tyi�w� __� . i�I1.tl!irrlitl■iriiiilil !!iA Mi!"�in , 1 I � �i� .�■■lr■I�Ilrlrl�ll�ll „■11■��� • w.p0.lrry - .11•1•••..wwwa- w1YM11111111.00111wA_ - REFLECTED CEILING PLAN - WEST 1/8"=1 EXTEND DRAFT STOP '(0 EXTER WALL DRAFT STOP CLG. T O ROOF DECK FACILITIES DEPARTMENT Rigitamo EXPOED OPEN WEB STEE JOISTS, REF STRUCT STUDIO CEILING LIGHTING GRID, REF All FOR CONSTRUCTION AND CONFIGURATON PLAN NORTH PS G % ❑ AUBURN, WA. 98002 ❑ BELLEVUE, WA. 98008 ❑ EVERETT. WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 11 SEATTLE, WA. 98124 Cr) EXHAUST DUCT REF MECH //A/al n - � - - -- � , " !�l�� 1 �l� R 10111111 1 II 1111 1 1 11101 tilliiiif ill11111111111111111111111111111 Nifiridli r i, ..„. - mil al iimArimi fa irmit i i i iiiirt i iii iI 1 II uii ii u i iirn i iniuI " I � I • - �II i"'i � ���� l��� i . IN ' +rrr +.+ ■ ■ �� ■ ■ ■� )��■ ■ , � I ■ ■r■ �r■ , � � ■ i■ N��1.. ■..� � ,� '� �. =■ ■ �i��i■�� i�� ii� ■ ■■■ ■ ■ ■ ■ .■ ■! 1 1 ■I■■■II1■ =i l l. � ■ ■� Dr %.I ^+4 rr � � I1 LAY ■� rn i i i w ; :i:! 1 . I 111 -� i �A. 7ilwarny.. .. .. .. . $ 11111 ....� .,..R �•.. ... P A R T I T I O N CONT. ABOVE CORR. CLG. CURTAIN TRACK, REF. A -i1 (IIIIIIII 11111 111111111,111 ITjIIIllVITIIlllillllllITIIiIIIIIIIIIIIIIIIIIITIIIIIIIIIIP11111111111II11111I111111TITIIIIIIPIIII {II 1111111111 111II!III111111IIIIIIIIII HILL! 0 .,.Ng i'«. 1 2 3 4 5 6 7 8 9 10 NOTE: If the microfilmed document is less clear than this . notice, it is due to the quality of the priginal document. APPROVED BY OFFICE ADDITION 87059 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED • y `j. �3 P�,i .4 %s 1 ! C r . ... i . E , n 11 MOE If; GERMANY 12 0€ 6Z se LZ OZ SZ *.Z CZ ZZ LZ Oz 6L St LI 91 St hl CL Zt tt 01, 6 s L 9 S � C Z t WW 0 IIIlillilll !llllliilllln!111!IIII lirl!II!II!li11111 1111lllllllllll IIIHIII(111l III!II 11 1 IIIIIIIIIIIIHIII11 111111 IIII!! 1! 1! 1111111111111I1111IIIIII111111IIII111111 !HIIIIIIII!II!IIIIIIIII I II I I III. .:. . :. ! ! IH1i 11111111111 — 5/8° GWB CLG. ON •X. . ING 2X CLG. JOISTS BETW ►EN EXISTING PURL I NS do ' EAMS TYP. RU. 149 CLG. PARTITION CONT. ABOVE CORR. CLG. REFLECTED CEILING PLAN - WEST Z ARCHITECTURAL WALLS AND PARTITIONS TO OR THROUGH CEILING EXPOSED EXISTING STRUCTURE ..._.._... LAY-IN SUSPENDED CEILING 11[1 1 ADHERED ACOUSTICAL CEILING TILE DRAFT STOP OR CLOSURE TO ROOF ABOVE CEILING 11 ROOM NUMBER MECHANI CAL SUPPLY AIR DIFFUSER SLOT DIFFUSER 23 RETURN AIR AND EXHAUST GRILLES EXPOSED DUCTS AND PLENUMS . .'. 6. PROVIDE AND INSTALL AIR DIFFUSER 7. PROVIDE AND INSTALL TRACK LIGHTS REFLECTED CEILING LEGEND F I ELECTRICAL SUSPENDED FLOURESENT INDUSTRIAL FIXTURES OR SURFACE - MOUNTED FLOURESCENT FIXTURE Pi5E1 LAY -IN FLOURESCENT RECESSED TROFFER WALL - MOUNTED FLOURESCENT COVE UPLIGHT 3i RECESSED INCANDESCENT DOWNL I GHT EXPOSED CABLE TRAYS a CEILING MOUNTED TRACK LIGHT REFLECTED CEILING NOTES 1.REFER TO SHEET A -7A FOR PORTION OF THE WORK EAST OF THE MATCH LINE. 2.ELECTRICAL AND MECHA EQUIPMENT, DUCTS ,CAB ARE PICTORAL ONLY, R ACTUAL CONSTRUCTION. 3.REFER DETAIL 15/A -6 LATERAL BRACING. 4.STUDIO CEILING LIGHT ONLY, REFER TO SHEET CONFIGURATION AND CO S.FIRE SPRINKLER HEADS INTERFERENCE WITH ME II..': ENT AND FIXTUR RECEIVED CITY OF TUKWILA MAY t 4 1991 PLAN NORTH PECINi!TCENTER • 0 BE&C ENGINEERS TITLE MOTION PICTURE AND TV AREA BUILDING 133 GATEWAY BUILDING ;4 NICAL F LE TRAY EFER TO FOR SUS ING GRI All FO NST RUCT SHALL CHANICA ES IXTURES, S, ETC SHOWN MECH & ELECT FOR PENDED CEILING D SHOWN IS PICTORAL R ACTUAL GRID ION. BE LOCATED TO AVOID L AND ELECTRICAL DWG. KO. 7.33 -A7 t.W -144 4 Dco JAM 5 (givtr ) 1 DOOR_ 11; '-D" P.F.e.'002 PlAkia 00 8000 4076 Rev. 7183 REVISION PkSvit-411-ler? LIcaHT cosae i-toLLow MET,6,1.. FRAME. DOCe, J Iver, roe CONM2UcTIOki 5TILL NOTO GOPB woor Poog. CANiziveT DQO FO.,/s\ME A5 A') AOA eyx 4 1 1+ 1-11) • rot-4c.. L. at„ ,FAcTote( 1-4Azost-let) 4 P1--17 FAI■IEL EDCAS CONcoriauCTION DEPT NOIFJ7 DCDOR -0" 15 TDOCYZ: 4 1-" w L 5% Q) J4 4 1-4)4?-1/4 1 FW1.) tzE.e -exic21 r opEA, tzEmbve r,x30R. ,-s 000R. — E L.)Pit •L ' A EtR Isj .-1 - 7 T 1 %L- AT7 .-Per4K0 1C0C„v - coNc. 1L. f)t-&r- Dode. JAI\41 ( '*1‘: I Fotztatklel 12E; - t ra... - r- LbAt..t.- ta-ltW - MACK, c uf - .11 . 3t)fei 1 rApoR it-4 REVISION Nay-1 1;71 QF FM :JAm1 - rt24,0‹. E • DUPLICATION C1 9024+ Dooe 3 44? DOC:j12,. LL " l2 4-,n2ucr. F012 Ft2ANM-16 121MBIs-4. DETAILA) w/ r2o012, EQ. E.Q. 4 7poiQ.OP tt 1 F 2AM E ELEN. C3) &Of) C11-it-JEt Tfre")e) FAME12 17P,L: 20 C. 1 a 3 GROUT FILLE.r) 16, 12APWAE1 r):X)P. Fgwe 69.ou1 r 1 16.0 �itS., CAST", Cf :14 ACOUSTICAL 5J-4T vv/ 120C? CONT. ome... SAMP.v.1.11,4E.K') PILL 0TiviNT ArnUSTAtV1-.S D002 Si IA)012 J4,\/11 (Ho) ardritEfAVA7 FACILITIES DEPARTMENT DOOR- 74\4E7 AV?) • iNTrACH ...YAK/0 be. 22 :%4.A.41 - Itzitvt - to veTzT MAT'L-)5.)e-FIIVAI0 /4- 5 Va." Hokiz. 0 0 , Rise,FMT FOR I V.4)' DOD 5A15 -ST012.E.FIZONT 3"... tit ,...e POOR. ptviK0 IGE5A EI-4 M4T 6 • - 1.5C1A, 24T. MET 4-1w ONC. WALL APPROVED AUBURN, WA. 98002 O EVERETT, WA. 98201 O KENT, WA. 98031 ' 0 PORTLAND, OR. 97220 0 RENTON, WA. 98055 • SEATTLE, WA. 98124 Cwt cAtzooT FiLLe.r, 1C0 CAA c-ANCaLS gis2to2er F12.At4e 1 orci stiecwvip, 4.cous '1')! to/kv,vem. 12oc Iiilltliitilalinligairri ..11 EXIVT 200R TV-Ac D\_)12. FRAME ELEV. IS i/4" t--1 rap.ma N.M. - r7ook... ACCEPTABILITY - Nis DESIGN AND/OR SPECIFICATION is APPROVED -- 91-)1... 6"x 20 OA- lot): U.Atvir), FuLL 14f. CONC. 4L,A9', lc/ HW\P TAPINc..4 IDO OR, :.7 4\t'v1e ( "; 1)OC ILL 5/ c.A (01 DOOR 51LL, FC)1 3" C.I.-1;a1...11•415L. ATTAGNME)+11 COt-iSTM)GTIot 20/A9 E.)(c.EFT , 7 SUBTITLE Coy zAfro Acowri 4 ,.4 61 4J T • @ LAilv 11-4To cArzoor th"1 60/41 LAP Iwo ALL Ar-OL 4000 %V1f PERNUTCENTER POoR. DETAIL ' DOOR LL JQ8#91t.12O1 CAvo, Cp2.).*) &woo" DWG NO A5 Ar As A9 c.oti.trreucjiom r20/A, y'FrA 'NOrel2 1_ - - -r, . . 6 p, I A _.10,4\‘, 4INYL:_.161.5 --- C.)M O : iv? 0- 06 ; *\ 0 ge.A-L3.4r wip __ _ OCW2i, r _O. ro-,-;1--.6.0A-6-6,,,Askc. 174-e5-F2._ 1 LL ii (7;\ APPROvED BY Log OF: IAA Bid , . . . . • „.„4 r . , • 1 111111 0 16 YHS INCH 1 2 : 3 4 r- 3 6 7 8 9 , 10 • 11 momomom 12 NOTE: If the microfilmed document is less clear than this • . . . notice, it is due to the quality of the original document:. 06 6Z 8G LZ 97, SZ VZ CZ ZZ oe 6l 91 GL 4 71 CI Zt. pi, 6 , I. 9 G E "" 0 • 1 " m, r SD \235 CFM 8 "RD. S.M. (TYP) BOTTOM OF DIFFUSER 10' -0" AFF (TYP 6) 200 CFM (TYP 2) 10 "RD, S.M. TYP) BOTTOM OF DIFFUSER 10' -0" AFF (TYP 4 �Ir 16/10 940 CFM 470 CFM 360 CFM 50 CFM 0 VO O 12/12 FE 1440 OC CFM 5.08.91 TG 270 3 CFM 180 CFM. 10/12 12/12 �. _480 CFM I 38/12 r 939f FM /f 10 � T a AG 30 30 ©CFM 1220 CC CFM 610 CFM 'AG (TYP 2) 1 610 CFM nisdaeimr2lawammu 2 CFM 20 CFM 800 CFM 204Sf CFM 10/10 EF 250 CFM min ' 560 FE CFM 122 1 F M L [ (TYP 4) © 334S?' 360 CFM Ar CC 400 08 CF M 692SF AG 200 CFM F� (TYP 2) 02 CFM SD 140 CFM 140 EM CF l.! 20 CFM 260 CFM F M \ 6 / 200 CFM (TYP 2) 100. 120m 200 CFM ( YP 5) FE 180 CFM 13D 180 1240 CF (TYP 3 2219SF 260 CFM /LD\ 180 \ 2 / CFM ==�F = n 12/12 12/12 , .I. ' nn;, }r i'�mmrr 2 1 5 E-F M ( Y 2) F +3 08 CFM 810 CFM 120 UP 10 ROOF CAP- 314Sf 1 - fiO - 10/10 180 CFM 50 CFM (TYP 2) 100 20/12' NEW 100 TO PLEN FOR CON CFM 95 'AG CFM 2 300 CFM (TYP 6) 1500 SD 235 CFM 1 ( YP 4) MAXIMUM NOISE COEFFICIENT (NC) TO BE 30 (TYP 4 CCC -60). 27. MAXIMUM NC LEVEL TO BE NC35 UNLESS OTHERWISE NOTED. APPROX. LOCATION OF STATIC PRESSURE SENSOR FOR UNIT ACU -1. APPROX. LOCATION OF STATIC PRESSURE SENSOR FOR UNIT ACU -2. 44 "X 24" OPENING IN WALL ABOVE CEILING (TYPICAL 2 LOCATIONS). F ALL TRANSFER GRILLES (TG) TO BE LOCATED ABOVE TOP OF CORRIDOR UNLESS NOTED OTHERWISE. SYLI 1040 CFM 260 CFM M ER 550. 1 15/15 UP TO 12/12 U' TO (NOTES & 10/10 • 10/10 FLAG NOTES CONTINUED) REVISION REVISED TO ADD COOLING TO ANIMATION LAB h PMc 400 _ __� - - -; TOP OF TRANSUCR WILE TO BE 6" BELOW CEILING `Or MM 150 PROVIDE WITH FIRE DAMPER. 6" RD FROM TERMINAL BOX, TRANSITION TO 8X6 TO DIFFUSER. PROVIDE FIRE DAMPER WHERE DUCT PENETRATES CAP OF CORRIDOR. LOCATE BOTTOM OF DIFFUSERS 16' -0" FROM F.F. :i1 LOCATE BOTTOM OF DIFFUSERS 13' -0" FROM F.F. CHANGE OUT .COOL -ONLY THERMOSTATS & WIRING TO 2 -STAGE HEAT /COOL THERMOSTATS & APPROPRIATE WIRING �37 COOL -ONLY T E R M I N A L BOXES I N FILM VIEWING ROOMS #129 & #130 TO BE REPLACE WITH COOL /HEAT BOXES, VFE -12A. SEE SCHEDULE, DWG M -3 BY APPROVED f l.mpt l ROOM ADDITION, JOBS 91PE062 C STILL PHOTO - ISSUE FOR 90% REVIEW I RS KMR 3 YP 3) CFM GATE SYB REVISION (TYP 2) (4) STILL PHOTO - ISSUE FOR CONSTRUCTION ECREASE CfM'S F RECORD DRAWING ktDO x'"74.87 G ISSUED FOR REVISION -JOB NO. 89012 -050 3.3.88 11 I REVISED AUDIO CONTROL AREA AS SHOWN 9.05.90 0 34 2,0) E lD 350 CFM ( Y' 3) i i (TYP 2) APPROVED 350 DISCONNECT (2) 2 "0 FLEX FROM EXIST VCC -20 D X. INSTALL 10" RD. TO 8/14 SQ. ADAPTERS AND REC ANGULAR DUCT W/1 1/2" THK 1.5 PCF NEOPRENE COATED INTERNAL INSULATION. DUCT SIZES GIVEN ARE NET INSIDE. RECONNECT (2) EXISTING DIFFUSERS. INSTALL (2) ADDITIONAL. DIFFUSERS, SAME AS EXISTING. LEAVE THROAT DAMPERS OPEN ON ALL DIFFUSERS FOR MIN. NOISE GENERATION, >NC2O. . PROVIDE RD. TO SQ. ADAPTER & INTERNALLY LINED DUCT AS SHOWN FOR EXISTING VCC -12. 442_,->- C O N F I R M THAT DAMPER ON VAV BOX I S OPEN AND MODULATING. 350 -- T40 LTNEI� FLEX. DUCT (-1YPi , 1 4 (TYP 16) ED 175 CFM TYP 2) E.-Y 10 215 CFM 140 UNLINED SHEETMETAL DUCT, INSULATION, SEE SPECS (TYP) . CO) REMOVE 2 �S6D DIFFUSERS, & 80 DUCT BACK TO C� RUN NEW 100 FROM VCC -04 TO NEW DIFFUSER AS SHOWN COORDINATE LOCATION OF NEW DIFFUSERS WITH EXIST. LIGHT FIXTURES AND EQUIPMENT. ,...�.�....., ✓•.y„�.. r ,� . .,�,� -- .,.bpd °""` ADJUST OUTPUT OF TO 1050 CFM. cam, I. z WEST PORTION EAST POR SEE SHEET M -11 FOR UPPER LEVEL DUCTWORK THIS AREA. EXCHANGE TRANSFER GRILLE FOR 36/16 SIZE; M . CUT WALL AS NECESSARY. £r:Ty r= 1I1III111111II1III1111IIIIIIL IIIIIIIIIII +I 41 111 1 111 1 111 1 11I I I1I 111111II 111111111111111111111111111111111111111111111 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII1II1IIII111111111111111111111 ,`1IIIII.,.Ii > : 0 ieTHEINCH 1 2 3 4 5 6 7 8 9 10 11 wamGERMANY 12 NOTE: If the microfilmed document is less clear t'stan this notice, it is due to the quality of the original document. 06 62 Be LZ 92 SZ 4 72 CZ 22 lZ Oz 6l 8l LL 91 i *A el El I l 01, I 6 5 L 9 9 '' C 2 L WW p II! I�IIIIIIIII�IIIIIIIIIIIIIIIIIIi�IiIIIIill�lililllll�lllllllll 'II III!! I! �IIIIIIIIIIIIIIII! Illlllllli! IIIIilllli�! I; IIIII�IIHILII! IIIIiIIilllillllllll�iilllllii�lllIIIIII�Iillliill�il! Illlii�lllllllll�Illilllll�lilll I 'I I I I II , 'III Illf�llli�llll ,�( {I�IIIIIIII�IIIIIL, III .I.&llllillLlIIlIIdICIl ION 450 E /C f AI 14/10 TO CFM --1Tra.a 95 AG CFM 2 / 9 5 � CFI 2 95 CFM DUCT CONNNECTS 1M, SEE DWG. M -11 SDI L) LJ nc W � cn SEE SHEE M-11 t OR L NED SHEETMETAL '-" UPPER LE EL DUCTWORK SUPPLY PLENUM (TYP) THIS ARE NOTES & FLAG NOTES: RETURN AIR GRILLE RAG -1, 950 CFM (TYP 2). LINEAR DIFF. LD -6, 155 CFM (TYP 6) . RETURN AIR GRILLE RAG -5, 465 CFM ( TYP 2) . 12 NOT USED 91. 21 TERMINAL BOX VFE 08, 350 CFM WITH 8 "0 FLEX DUCT, & 8 "0 DUCT CONN. TO 28 "0 DUCT MAIN. PLAN NORTH TAUF y *0 :: 4,0404 , NO SCALE KEY PLAN TERMINAL BOX VCC -6O, 3240 CFM, WITH 38/12 FLEX DUCT AND 38/12 RADIUS CONN. TO 180 DUCT MAIN. TERMINAL BOX VCC -60, 3240 CFM, WITH 38/12 FLEX DUCT AND 38/12 COLLAR CONN. TO 200 OR 240 DUCT MAIN. ` TERMINAL BOX VCC -40, 1000 CFM, WITH 26/12 FLEX DUCT AND COLLAR CONN. TO 140 DUCT MAIN. TERMINAL BOX VCC -40, 1900 CFM, WITH 26/12 FLEX DUCT AND TRANSITION TO 160 DUCT. TERMINAL BOX VCC-40, 930 CFM, WITH 26/12 FLEX DUCT AND COLLAR CONN. TO 120 DUCT MAIN. LINEAR RIFF. ID-6, 165 CFM (TYP 6). RETURN AIR GRILLE RAG -5, 500 CFM (TYP 2). LINEAR DIFF. LD -4, 315 CFM (TYP 6) . 12/4 SCREENED OPENING 10" ABOVE FLOOR. PROVIDE 120 DUCT FROM TOP OF AIR BRUSH BOOTH FAN, APPROX. 5' -0" AFF TO ROOF; TO BREIBERT TYPE 'L' SIZE 14 AIR EXHAUSTER MOUNTED 3' -0" ABOVE ROOF. MAXIMUM NOISE COEFFICIENT (NC) TO BE 20 THIS ROOM. DUCTS SHOWN WITH DASHED LINE INSIDE DENOTES DUCT TO BE ACOUSTICALLY LINED. DIFFUSERS TO BE LOCATED NEXT 10 AND EVEN WITH BOTTOM OF JOISTS. COORD. DIFFUSER LOCATION WITH PIPE GRID TO AVOID AIR FLOW BEING INTERRUPTED BY PIPES. FOR TYPICAL TYPE "VFE" MINAL BOX AND LINEAR DIFFUSER CE IONS, SEE DETAIL FOR TYPICAL ROOF MOUNT EXHAUST FAN, SEE DENI. (T M -10Im1 501 FOR TYPICAL RETURN AIR SOUND SEE DETAIL 0 1 DUCT FITTINGS TI BE USED THE TYPE INDICA D ON TH PARTICULAR Y: F96° - TIES ), L TEES (ire, );; Y - BST - ITUT T - i --C}TR �ilCT SHOULD BE OF E DRAWINGS. 45°, 90° TEES (,.h, ) ; 'Y' FITTINGS (< ) OT ACCEPTABLE. FIELD IZES AND LOCATION MAY F i l - ATIMEDHAFFEC ff SYSTEM BALANCE. I ALL DUCT I I ZES DIMENSIONS. DIFFUSER�LO' I S MAY BE ADJUSTED IN FIELD TUN- �. PI NUM SIDE UP WITH TRIANGULAR OPEN G IN WEB OF JOIST. I F140 .. DUCT AS REQUIRED TO E RAT i g: O11 JOIST AND TO ALLOW -C-T -1 ON TO S E OF P L E NUM/' (NOTES & FLAG NOTES IONT. Tt LOW 'E FT OF THIS DWG.) .'I BY K O'W AR KOW P Mc PM C KMR KMR DATE 3.10.88 6.22.88 10.28 . 8l 06.16.8' 02.06.8 tz:V/A__W FACILITIES DEPARTMENT ❑ AUBURN, WA. 98002 0 BELLEVUE, WA. 98008 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RE NT ON, WA. 98055 ® SEATTLE, WA. 98124 1 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT PP AWN EY 1 T I E MOTION PICTURE AND TV AREA BUILDING 7-33 GATEWAY BUILDING 04 ROOM ADD'N J. 91PE062 SHEET MiO JOB NO. 81059 DWG. NO. 7.33 -IM10 OF 5 12 "X 21 "X 16 "DE ATTACHED T O NEC WEST PORTION EAST PORTION RECEIVED CITY OF TUKWILA MAY 1 4 199i PERMIT CENTER 8E84 ENGINEERS HVAC PLAN FIRST FLOOR WEST ,— d E CLEAR INSIDE LINED SUPPLY PLENUM, OF DIFFUSER (TYP) . w ❑ 05.08.91 i a N -Ng F 1040 OB CFM 260 CFM ( Y. 4) 235 CFM -- (TYP 4) 235 CFM ER 550 1 CFM 15/15A UP TO UP TO act 8 "RD. S.M. (TYP) BOTTOM OF -- DIFFUSER @ 10 -0" AFF (TYP 6) t 20/18 OPENING IN WALL ABOVE ADJACENT CEILING. F 940 12k CFM 470 CFM 10 "RD. S.M. (TYP) BOTTOM OF DIFFUSER 10 -O" AFF 360 CFM CC 10 12 CFM 12/12 KMR /DM KMR /DM DATE SYM 9.05.90 3.21.91 E 140 CFM LD - (TYP 4) 2 MP" 560 F E CFM 1 CFM 1 SFC F M (TYP 4) WASNIMININIUMMIIMI 1011 80 1 WF . r 38 80 0 CFM 39 800 4u 4.0SF 250 CC . --� CFM 04 pp:: ___ ___ _ - — gi lib Itims==-1,7,4 560 CFM 50 SD Ems!! FM 6 Ar 200 CFM 400 _(TYP 2) 08 CFM 692SF 200 CFM (TYP 2) DECREAS CFM'S RECORD DRAWING ISSUED FOR REVISION -JOB NO.89012 -050 REVISED AUDIO CONTROL AREA AS SHOWN KMR KMR 6.22.88 10.28.8 12/10 UP TO 470 200 CFM (TYP 5) LD 180 \ 2 CFM APPROVED DATE BY K O'W AR KOW P MC 06.16.8 P MC 02.06.8 12/4 470 3.10.88 610 CFM REMOVE T'STAT & HOLD FOR RELOCATION 135 CFM ❑ AUBURN, WA. 98002 ❑ BELLEVUE, WA. 98008 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 a SEATTLE, WA. 98124 a { ... r :° .l.sc y_i a.. �. `r'! ..,.i.,+ a �,�, s . s: v: �,�C' j �: i• c r 2 120 UP TO ROOF CAP 10/10 314SF O t° TITS INCH 1 2 . 3 4 5 6 7 8 NOTE: If the microfilmed document is less clear than this notice, it is due to the quality of the original document. ' 06 6Z Oc; LZ 9Z SZ .1 73 £Z ZZ tZ Oz 61. et Lt 9L 9L ht £L ZL tL 41, 6 8 4 9 S 1 7 £ I 10/10 UP- T- $ -3 `TG 40 � ri)usl ', n �I 7 I. trj %t% u I I II �rlr1 � � 1 /lir LL�1Irr � w '� , / ..._a..., r . , . -owe e--r 0 o . VR►rilljrANlr 1 APPROVED BY IIIJIIIIIIIlIlIlIlIlIJIIJI IIIIIIIIIIII ail 111+ 111IIIIj111I111111111111111111111i 1111111 11111111 1II1IIIIIIIIIIIIIII111111111 1�i 1i'1111111.11111III1i11111 VIII . 111111I . I . IIIIL . 'I111111I11 I 9 10 11 mADE7NOCRMA. 12 L"0 11111;!(11H 11 I {111111111IiA111111!IilW1111111 1iI1i1i1111i1111If11M11 111i114I1 Hllililll4lHll iii' t !1111 01111n11111i11111 01101.11 0. 1 I ti � II .� IIIIIII�IIIII.IIInluI111111 1111111111 10/10 G 180 2 CFM ►� :� :4, . l 1 i I I i WWII& ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED Dr — 50 CFM (TYP 2) --100 TYP 14/12 100 -0 CFM 335 CFM (TYP 3) 345SF 95 AG CFI 2 95 LD CFM',' `~-- 95�� 20/12 NEW 100 TO PLEN FOR CON C M 02 95 CFM 02 95 LD TITLE HVAC PLAN -- DEMOLITION FIRST FLOOR WEST MOTION PICTURE AND TV AREA BUILDING 7-33 GATEWAY BUILDING 84 BE&C REM ENGINEERS DRAWING DWG. NO. 1040 MAXIMUM NOISE COEFFICIENT (NC) TO BE 30 (TYP 4 4CCC-60). 27. MAXIMUM NC LEVEL TO BE NC35 UNLESS OTHERWISE NOTED. (NOTES & Q -J FLAG NOTES CONTINUED) APPROX. LOCATION OF STATIC PRESSURE SENSOR FOR UNIT ACU -1. APPROX. LOCATION OF STATIC PRESSURE SENSOR FOR UNIT ACU -2. 44 "X 24" OPENING IN WALL ABOVE CEILING (TYPICAL 2 LOCATIONS). ALL TRANSFER GRILLES (TG) TO BE LOCATED ABOVE TOP OF CORRIDOR UNLESS NOTED OTHERWISE. REVISION 200 CFM (TYP 2) REVISED TO ADD COOLING TO ANIMATION LAB RECORD DRAWING ISSUED FOR CONSTRUCTION LOBBY RELOCATION STILL PHOTO - ISSUE FOR 90% REVIEW 2 400 APPROVED 320 CFM 6/12 C F M 60 10/12 12/12 (TYP 2) M TOP OF TRANS ER GRILLE TO BE 6" BELOW CEILING s RIM 150 PROVIDE WITH FIRE. DAMPER. 6" RD FROM TERMINAL BOX, TRANSITION TO 8X6 10 DIFFUSER. PROVIDE FIRE DAMPER WHERE DUCT PENETRATES CAP OF CORRIDOR. LOCATE BOTTOM OF DIFFUSERS 16' -0" FROM F.F. LOCATE BOTTOM OF DIFFUSERS 13' -0" FROM F.F. REVISION STILL PHOTO - ISSUE FOR CONSTRUCTION 36 CHANGE OUT COOL -ONLY T H E R M O S T A T S & W I R I N G T O 2 -STAGE HEAT /COOL THERMOSTATS & APPROPRIATE WIRING COOL -ONLY TERMINAL BOXES IN FILM VIEWING ROOMS '129 & 1130 TO BE REPLACE WITH COOL /HEAT BOXES, VFE -12A. SEE SCHEDULE, DWG M -3 i i 350 CFM ( YP 4) 1 ! I ,,.., L 1 "1 1 C)11 Joe, ► .. Sn '- 4 PG: b2 ----. 1 M ii REMOVE LINEAR DIFFUSER, FLEX CONN, & 6/12 DUCT. CAP OFF & SEAL AIR TIGHT AT ADAPTER. 12/12 12/12 UI 20 CFM S D 2 6 ,. I&%_ '�lllllrn,�, (TYP 2) 240 e j Y P 4) 6 C ?� CONFIRM THAT DAMPER ON VAV BOX IS OPEN AND MODULATING. 20 CFM (TYP 3) DISCONNECT (2) 2 "0 FLEX FROM EXIST VCC -20 B X. INSTALL 10" RD. TO 8/14 SQ. ADAPTERS AND REC ANGULAR DUCT W/1 1/2" THK 1.5 PCF NEOPRENE COATED INTERNAL INSULATION. DUCT SIZES GIVEN ARE NET INSIDE. RECONNECT (2) EXISTING DIFFUSERS. INSTALL (2) ADDITIONAL DIFFUSERS, SAME AS EXISTING. LEAVE THROAT DAMPERS OPEN ON ALL DIFFUSERS FOR MIN. NOISE GENERATION, >NC20. R c : :::::;:» PROVIDE RD. TO SQ. ADAPTER & I NTE RNALLY LINED - DUCT AS SHOWN FOR EXIS, .,G VCC -12. 1441ST 810 CFM (TYP 16) T CINEf — L E X DU� _ S LY PI-_ 75 CFM YP ) 215 CFM ( YP 140 UNLINED SHEET METAL DUCT, INSULATION, SEE SPECS (TYP) . 6) REMOVE 2 6 DIFFUSERS, & 80 DUCT BACK TO E8) SEE SHEET M - 11 FOR UPPER LEVEL DUCTWORK THIS AREA. L a NED SHEET METAL SUPPLY PLENUM (TYP) RUN NEW 100 FROM VCC -04 TO NEW DIFFUSER AS SHOWN. EXCHANGE TRANSFER GRILLE FOR 36/16 SIZE; • . CUT 'WAIL AS NECESSARY. 45 COORDINATE LOCATION OF NEW DIFFUSERS WITH EXIST. LIGHT FIXTURES AND EQUIPMENT. 1'2 FM WEST _ PORTION I EAST P ( 6) ION SEE SHEE M -11 FOR UPPER LEVEL DUCTWORK THIS AREA. KEY PLAN 00 SCALE 450 CFM 350 CFM CFM 95 CF \ 2, 300 CFMKSD) (TYP 6) 1 1500 GEM NCI CONNNECTS M, SEE DWG. M -11 It L T .i PLAN NORTH 1404SF 2 NOTES & FLAG NOTES: 21 TERMINAL BOX VCC -60, 3240 CFM, WITH 38/12 FLEX DUCT AND 38/12 RADIUS CONN. TO 184E DUCT MAIN. TERMINAL BOX VCC -60, 3240 CFM, WITH 38/12 FLEX DUCT AND 38/12 COLLAR CONN. TO 200 OR 240 DUCT MAIN. TERMINAL BOX VCC -40, 1009 CFM, WITH 26/12 FLEX DUCT AND COLLAR CONN. TO 140 DUCT MAIN. TERMINAL BOX VCC -40, 1900 CFM, WITH 26/12 FLEX DUCT AND TRANSITION TO 160 DUCT. TERMINAL BOX VCC -40, 930 CFM, WITH 26/12 FLEX DUCT AND COLLAR CONN, TO 120 DUCT MAIN. LINEAR DIFF. LD -6, 165 CFM (TYP 6). RETURN AIR GRILLE RAG -5, 500 CFM (TYP 2). LINEAR DIFF. LD -4, 315 CFM (TYP 6). RETURN AIR GRILLE RAG -1, 950 CFM (TYP 2). LINEAR DIFF. LD -6, 155 CFM (TYP 6). RETURN AIR GRILLE RAG -5, 465 CFM (TYP 2). NOT USED 12/4 SCREENED OPENING 10" ABOVE FLOOR. PROVIDE 120 DUCT FROM TOP OF AIR BRUSH BOOTH FAN, APPROX. 5'--0" AFF TO ROOF; TO BREIBERT TYPE 'L' SIZE 14 AIR EXHAUSTER MOUNTED 3' -0" ABOVE ROOF. MAXIMUM NOISE COEFFICIENT (NC) TO BE 20 THIS ROOM. DUCTS SHOWN WITH DASHED LINE INSIDE DENOTES DUCT TO BE ACOUSTICALLY LINED. DIFFUSERS TO BE LOCATED NEXT 10 AND EVEN WITH BOTTOM OF JOISTS. COORD. Dlr LOCATION WITH PIPE GRID TO AVOID AI"R FLOW BEING INTERRUPTED BY PIPES. FOR TYPICAL TYPE "VFE "� MINAL BOX AND LINEAR DIFFUSER C NE'� IONS, SEE DETAIL FOR TYPICAL ROOF MOUNT EIXHAUST FAN, SEE DETAJ L M -10 M -501 FOR TYPICAL RETURN AIR S SEE DETAIL RECENT() CITY OF TIJKWILA HAY 1 4 1931 P ERMITCENTER u M -10 5O 1 DUCT FITTINGS T THE TYPE_INDICA PARTICULAR Y: 9 a °_. E - E S c i 45° TEES (:,) ; Ir -- i1} H-S-T- T i � ARE C-+-A -N_•G — 5--• t . 'T} U C T F - T A AFFEC i ALL DUCT $ IZES DIMENSION . 12 "X 21 "X 16 "DE ATTACHED TO NEC DIFFUSER l0_ FIELD TO LT TRIANGULAR OPEN 41/F T 040 �rPE(JE RATS:_ tO - C - H 0N TO S (NOTES & FLAG NOTES OF THIS DWG.) 01 BE USED SHOULD BE OF D ON THE DRAWINGS. 45°, 90° TEES (,,.4 ); 'Y' FITTINGS ('< ) OT ACCEPTABLE. FIELD ICES AND LOCATION MAY SYSTEM BALANCE. E CLEAR INSIDE LINED OF DIFF S MAY B NUM SID G IN WE WEST PORTION EAST PORTION SUPPLY PLENUM, USER (TYP) . E ADJUSTED IN E UP WITH B OF JOIST. UCT AS REQUIRED TO JOIST AND TO ALLOW E OF PLENUM A \ ONT. TO LOWL-FT • C) C) 00 '11 SHEE N0. TiTIE DRAWING N0, REVISION NO. ELECTRICAL El INDEX & SYMBOLS ' 7.33 -El E E4 ONE -LINE DIAGRAM 7.33 -E4 D E6 PAGING, ADT & TELEPHONES 7.33 -E6 D E7 DATA CABLE SYSTEM 7.33 -E7 C E7A DATA CABLE SYSTEM 7.33 -E7A A E8 OUTDOOR LIGHTING 7.33 -E8 E9 GROUNDING 7.33 -E9 0 ElO LIGHTING PLAN 7.33 -1E10 G Ell LIGHTING PLAN 7.33 -1E11 E E11R LIGHTING PLAN (REMOVALS) 7.33 -1E11R A E60 120/208 VOLT POWER 7.33 -1E60 H E61 120/208 VOLT POWER 7.33 -1E61 E E110 277/480 VOLT POWER 7.33 -1E110 El11 277/480 VOLT POWER 7.33 -1E111 D E500 MOTOR CONTROL DIAGRAM MCC -1 7.33-E500 E501 LIGHTING SCHEDULE & DETAILS 7.33 -E501 H E502 DETAILS 7.33 -E502 E503 STUDIO PLANS & DETAILS 7.33 -E503 E504 PANEL SCHEDULES 7.33 -E504 A 0 0 30 Ie. 50 30 ICE GFI 20 3 Elih -sc SURFACE METAL RACEWAY OR PLUG MOLD CABLE TRAY (SIZE AS NOTED ON DRAWINGS) CONDUIT CONCEALED IN MALLS OR CEILING UNLESS OTHERWISE NOTED SYM i A LE( ;E 4 (UNLESS OTHERWISE NOTED) 41,0V MOTOR (SIZE AS NOTED) 208V OR 230V MOTOR (SIZE AS NOTED) 115V MOTOR (SIZE AS NOTED) CIRCUIT BREAKER, AIR a ..6 DISCONNECT SWITCH E❑] FUSE (2) 15A DUPLEX RECEPTACLES, HUBBELL 5262 SITITORRIr CO TRANSFORMER (CAPACITY, PHASE, & VOLTAGE AS SHOWN) 30A, 480V, 3 PHASE, CROUSE -HINDS ARE-3482, STYLE 2 50A, 120V, 1 PHASE, SINGLE, HUBBELL 9360 30A, 120V, 1 PHASE, SINGLE, HUBBELL 2610 15A, 120V, 1 PHASE, DUPLEX, HUBBELL 5262 15A, 120V, 1 PHASE, SINGLE, HUBBELL 5261 15A, 120V, 1 PHASE DUPLEX WITH GFI, HUBBELL GF -5262 15A, ISOLATED DUPLEX RECEPTACLE, HUBBELL IG 5262 20A, 120/250V, 1 PHASE, SINGLE, HUBBELL 8410 WIREWAY (SIZE AS INDICATED) B U R I E D CONDUIT & W I R I N G (UNDERGROUND & I N FLOOR SLAB) FLEXIBLE METAL CONDUIT OR LIQUIDTIGHT FLEX AS NOTED MARKS INDICATE QUANTITY OF CONDUCTORS (SIZE AS NOTED). SHORTER SLASH INDICATES PHASE CONDUCTOR LONGER SLASH INDICATES NEUTRAL CONDUCTOR BACKSLASH INDICATES GREEN GROUNDING CONDUCTOR. BACKSLASH WITH CURL INDICATES GREEN WITH YELLOW STRIPE ISOLATED GROUNDING CONDUCTOR WHERE MARKS ARE OMITTED, CONDUIT CONTAINS (1)EACH 512 PHASE CONDUCTOR, & 112 NEUTRAL. CONDUIT TURNS DOWN ...�... ...O CONDUIT TURNS UP GROUND CABLE ( UNDERGROUND) & CABLE CONNECTION n GROUND ROD LOCATION GROUND CABLE PIGTAIL MEM FIRE ALARM PANEL (ADT) 01D PANELBOARD, 480Y/277V, 3 PHASE PANELBOARD, 208Y /120V, 3 PHASE REVISION .. r w... r.... sor. r. .— .....w.w... ISSUE FOR 909E REVIEW ISSUED FOR CONSTRUCTION LOBBY RELOCATION STILLPHOTO - 909E REVIEW FILLPHOTO - ISSUED FOR CONSTRUCTION JUNCTION BOX � DISCONNECT SWITCH (FUSED OR UNFUSED) 30T2O (SWITCH RATING / FUSE SIZE) NF = NON -FUSED --FA- FIRE ALARM CIRCUIT (ADT) C.O. CONDUIT ONLY EG EQUIPMENT CONNECTION LIGHTING CONTROL Chi LIGHTING CONTACTOR - MAGNETIC SINGLE POLE TOGGLE SWITCH, LINE VOLTAGE DIMMER /ON -OFF SWITCH 5, (1) LOW - VOLTAGE LIGHTING CONTROL SWITCH AND SWITCH LEG:1 /2 " -3t18 (2) LOW VOLTAGE LIGHTING CONTROL SWITCHES 2 DI AND SWITCH LEG:1 /2" -5118 LOW - VOLTAGE LIGHTING CONTROL RELAY. NUMBER INDICATES QUANTITY OF RELAYS. SEE SHEET E501 FOR TYPICAL WIRING. •--- L.v-- LOW - VOLTAGE L I G H T I N G CONTROL W I R I N G I N 1/2" RACEWAY. CONCEALED UNLESS OTHERWISE NOTED. THREE CONDUCTOR 118 AWG, UNLESS OTHERWISE NOTED. LIGHTING FIXTURES $v SEE FIXTURE SCHEDULE, SHEET 1E501. "X" DENOTES FIXTURE TYPE "Y" DENOTES TOTAL INPUT WATTS COMMUNICATION TELEPHONE RACEWAY ONLY, SIZE AS SPECIFIED. - .--- m -_.-- PAGING CIRCUIT TELEPHONE OUTLET SZ DATA /COMMUNICATONS OUTLET ® PAGING SPEAKER SPEAKER ON /OFF -- VOLUME CONTROL ABBREVIATIONS A.F.F. DED GFI LV MCC N.I.C. PNL WP XFMR REVISION ISSUED FOR RECORD DRAWING ABOVE FINISHED FLOOR DEDICATED GROUND FAULT INTERRUPTER LOW VOLTAGE MOTOR CONTROL CENTER NOT I N CONTRACT PANEL WEATHER PROTECTED TRANSFORMER / g/49y // ;! FACILITIES DEPARTMENT osorrarto BY R.KENT JRB R.KENT APPROVED DATE SYM 6.12.8 E 6.25.8 � MJB/DM p4141 � 4141• I -' pie �' `� « i0• -n'CY , t -: .:.`Ai, �'+ .ri.. �' "•i) ti },. :r�ya� tr'�,S'^s - ✓ BY APPROVED H . L E EE . 0.25.88 IIIIIIIIIIIIIIIIII I II 11111111111 11V IIIIII IIIIII! II (I I IIIIIIIIIIIIIIII �L L IIIII III111 1 � i ILI1I (illi'iILIIII 1lllllaIllll I I+III1IIIIL 0 ilTHSINCH I 2 3 4 5 6 7 8 9 . 10 11 MADE IN OER► 12 NOTE: If the microfilmed document is less clear than this ,, notice, it is due to the quality of the original document. Q^G 6Z Be LZ 9Z GZ te CZ ZZ re 0Z 61, 8l LI 91, S: hi CI Zi ll Q( 6 8 L 9 6 +l CE l wW 0 lILIIhI,I nllli!If 1lll l!IIIIIIIIIIIIIIILIILIII lflllil!I IIIIIIII!III{Iifil IIfII!fiI !!I!II!!IIIIIIilliiiiillllll IIIIIIIII il!illili lllll!!!I iifllilll IlIIIlIII IIIIIIiII IIIIIIIIIIII(I1II!lilll!Iilll !1!IIII!I IiI Il IIIIIIlllllilllllll,Ili fII III!!! IIIIIIIIi�II!Ililll�llliIIIIII I 4141 4141.. 4141 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY 9 EPT ❑ AUci1RN, WA. 98002 !J BELLEVUE, WA. 98008 ❑ EVERETT , WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 RI SEATTLE, WA. 98124 REFERENCE ONLY • INDEX & SYMBOLS ELECTRICAL MASTER BLDG. 7 -033 1ITLE 410•,,._.......•.0 • RECEIVED (ITV OFTUKWILA — MAY 1 4 1991 PERMITCENTER EiE&C ENGINEERS :�i^:'7`R:f y Y :0•i }0•i': : %, .c: 'r3 { REVISION ISSUE FOR 90% REVIEW A ISSUED FOR CONSTRUCTION LOBBY RELOCATION HY APPROVED DATE R.KENT R.KENT 6.12.87 REVISION BY APPROVED ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED -.. s a ::2 ="' _ :w...., _. / ° Cam : '`' , •�/' ; r �NJ ': '/. � ^, I ! I IIII IIIIIIIIIIIIIIIII1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1I t TII I I MILLI1 11ITI!J 1IIIII1I1I1IIIIt1IIII tII II'I 0 f0YHSIN 1 2 3 4 5 6 7 8 NOTE: if the microfilmed document is less clear than this notice, it is due to the quality of the priginal document. oc 6z 9G Lz 9z sz tZ CZ Ze re OZ 6i 9l Ll 91 Sl 4 ,1 cl zl U p 6 8 L 9 s , c Z 1 ww ( llllliilll!I!i1l!IIIIII!11!!Ill 1I!IIIII!i!IIIII111111iIIi 0 1{ IIIIII llIlilll! ! Ilillllil! ilillIIIIIIIIIIIIII! IIIIIIIIIiillllilIIIIIII !II{ I !IIIIIIIIIIIII!{1{II {lilll 1 ' i i' , i 1 0 . , II!(!J II II�IIII�iI� !1iIILI,III�,ll,tll,ll�,lll IIII�IIII �!! I�IIIII !I�!I!n!IIIIII!!Illinll!!!!1 11111111 11111111111111111111111111111111111111.11 9 10 11 INGEr:>m 12 } 1 .25.87 05.08.91 4) 3" RSC C.O. STUBBED THRU WALL WITH CAPS, MOUNTED OVER CABLE TRAY INTO THE BACK OF THE TELCO MOUNTING BOARD. 1 -1/2" EMT C.O. 1-- 1/2 "C.O. ABOVE SUSPEN CEILING 2" EMT C.O. ABOVE SUSPENDED CEILING - T: --�F- --- ------ 2" EMT C. O. MOUNT TIGHT TO CEILING O 12" WI TYPE, I•E1EPH E, 4" DEEP, LADDER ABLE TRAY FOR NES -- 10' A.F.F. k=fir— --a. =— = .= = {HIT 2 n itun 111111111 W MUD 6"X6" WIREWAY NE MA 1) WITH SCREW COVER MO NTED 4" ABOVE SUSPENDED CEIL NG, BY HANGERS ATTACHED TO TH!>ZEADED ROD. 18" WIDE, 4" DE LADDER TYPE, CA TRAY SUSPENDED ROOF STRUCTURE CEILING SO THAT TRAY IS 8'• -0" A.F.F. r "'"?' FACILITIES DEPARTMENT LE ROM HRU BOTTOM OF Y ID"-----= �'�'-�r- =• 1 USE VERTICAL TO CHANGE EI. WIREWAY AS N ❑ AUBURN, WA. 98002 ❑ BELLEVUE, WA. 98008 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 NI SEATTLE, WA. 98124 FITTINGS VATION OF CESARY Jr' 1 r � IC; WEST PORTION I EAST POR1 1" C.O. ABOVE SUSPENDED CEILING - (2)1- 1/2 "C.O. ABOVE SUSPENDED CEILING A.F.F 1S EE DETA l 1 DWG. 7.3} -E6 i ® k NO SCALE ILE 0 KEY PLAN CONSTRUCTION NOTES PROVIDE (1) VERTICAL RACEWAY (WIREMOLD G -4000 W /DIVIDER) FOR TELEPHONE & DATA CABLES & POWER CIRCUITS. ROUTE RACEWAY FROM 6" ABOVE SUSPENDED CEILING DOWN TO A FLAT ELBOW (WIREMOLD G -4011 W /DIVIDER) ATTACH THE FLAT ELBOW HORIZONTALLY TO AN INTERNAL ELBOW (WIREMOLD G --4017 W/ DIVIDER. ATTACH THE OTHER END OF THE INTERNAL ELBOW TO THE G -4000 DIVIDED WIREWAY MOUNTED Al THE BASF OF THE WINDOW (SEE SHEET E60) . i I ri PLAN NORTH N I lk 4 DATA CABLE SYSTEM U ---- -u , . a. -. a F ii RECEIVED CITY OF TUKWIlA MAY 14 1991 PERMITCENTER BE &C ENS!NEERS MOTION PICTURE ANDS TV AREA BUILDING 7-33 GATEWAY BUILDING #4 'OFFICE ADLIITION SHEET WEST PORT I ONEAST PORTION . ^. fly, ) fib -s .' mi -., -, C2) C -C� E7 d48 NO. 87059 Dik6 N0 7.33 --E7 i 0110110110101100 0 INN 0110101 t _ AM . C6- /32a C6- 2/22b,24c 24c C6- /16b,18c,20a 81/30c 81/26a,28 • • f, 0 :r a - 0111100 .�, M o . r TO CKT 14o RELAY COLUMN C3 -- R1/2o,4b,6c — B1 /1 4aS . — _ - -- = V---- ___. YIN Mai .. C6 -2/35 ■ 1U 1 111111 uu W.iu V1.2 LVI lvt O C6 2a,4b C8 -2 /1a CEILING MOUNTED TRACK MALL MOUNTED TRACK b 5c C6 -2/7a 9b 11c 6-2/1 o ,y 3' -0 TYPIC DiT1 B1 /20o LV 2b . Lv ! Lv1,2 it II `. _ ■r 1.t.2J C6 -2 /6c SEE 503 FOR LOCATI 26a TYP 14 A8 - 1/26o 2 111.2.3.4 30c TO CKT 14c RE AY C6- 2/31a,33b 28b 28b Ti CKT 14a RELAY COLUMN C3 26.0- _- - -. -- 4 4-- C 1 C -- rF� 10b TYP 7 REVISION FOR 90% REVIEW 11011 2c 12c 11271 1 TYP 28 L V --- -- --.. -. TYP 52 SYM 10b REVISION ISSUED FOR RECORD DRAWING DUPLICATION CENTER OFFICE ADDITION 1 i TYP 10 ILY ___.__ i EEO THIS AREA AS MODULAR FURNITURE WITH 120 V INDIRECT LIGHTING, INDIVIDUALLY SWITCHED AND FED FROM PANEL C6 -1. SYM 1 ISSUE L R.KENT R.KENT NC /DM 6.25.87 7.24.87 3.3.08 3.10.88 R.KENT JRB MJ B /DM ISSUED FOR CONSTRUCTION OBBY RELOCATION . ..,�. .. �....a........_�._. o . . . STILLPHOTO - 9 % REVIEW STILLPHOTO - ISSUED FOR CONSTRUCTION BY JRB APPROVED DATE 6.12.87 F 1111M111111111 10.25.88 BY APPROVED A•S • 11.09.90 J491012 -062 JC ' 05.08.31 1111111111111111M DATE TYP 36 _. __ — - -__ r rs 26a 41..1 -.._ .7..,0,..,_.......• ADIE/E'llAY0 FACII]TIES DEPARTMENT ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY 81059 LIGHT I NG PLAN A L r A MOTION PICTURE AND TV AREA BUILDING 7 -33 GATEWAY BUILD I NG 84 OFFICE ADDITION E T D. N0. 7.33-1E10 0 05.08.91 28b 81/18c TYP 16 0 AUBURN, WA. 98002 0 BELLEVUE, WA. 98008 0 EVERETT, WA. 98201 0 KENT, WA. 98031 0 PORTLAND, OR. 97 220 E0 RENTON, WA. 98055 M SEATTLE, WA. 98124 crp _ w -= 18c 18c PNL A8 4 WE PORTION I EAST POD ION Lv T Y2 2A___ TO CKT 140 RELAY COLUMN C3 YP 16 30c III II1I I11111111111111111I I'll 11111III1111 L1 111111111111111IWI11I11111111111111I11111I11111I1111I 11111I111111111111111 11111 ,l1111111111 • 0 10THSINCH 1 2 3 4 5 6 7 S 9 NOTE: If the microfilmed document is less clear than this , notice, it is due to the quality of the original document. 0£ 6Z Be LZ 9Z SZ 4 7Z CZ ZZ LZ OG 6t et LL 91 91 *'L CL ZL • Lt Dlr 6 IIIIIIIIIIlllilllillfl;! !iillillilliilllllill�ili iiill nlllllJ1iii1����11111 fllllll!, II�IlIII�II�II��lli�l !!!�IIIiJilii !li!��lli�i1 Iii)f)1iilli�l�l1i; i i;i 1 lllillil1Ill[ I11 11 !)(If!II;IIIIII�n1111111�11111 i; ,ri'1;li t1 1 111111111111 1 11111111111I11 10 11 ►WEINGERMANY 12 o c 7 c Z L r +r 4 0 IIILIi11iIIIII40,14011i111111illlll ildmilllli mil x--310 1 -- 1 11 1 r 1# ANE i D9 /310 n SEE SHEET Ell L. 310 1. r io GEMERALOTEL 1. ALL CONDUIT TO BE 1/2" E. Y.T . UNLESS OTHERWISE NOTED. 2. ALL DIRE TO BE f12 THWN /THHN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 -VOLTS OR LESS: 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5 FEEDERS TO PANELS SHOWN ON SHEETS [4 & [500. 6 SEE DRAWING 7.33 -E501 FOR LIGHTING FIXTURE SCHEDULE & MOUNTING DETAILS. 7 ALL 120V DIMMING CIRCUITS ARE TO HAVE INDIVIDUAL NEUTRAL CONDUCTOR FOR EACH PHASE CONDUCTOR. 8. ALL LIGHT AND DIMMER SWITCHES ARE MOUNTED AT 48" AFF, UNLESS OTHERWISE NOTED. CONSTRUCTION NOTES REMOVE AND RELOCATE DIMMER FOR EAST FIXTURE TRACK. P> INSTALL NSTALL NEW, MATCHING DIMMER FOR WEST FIXTURE TRACK. REMOVE EAST TRACK FROM CIRCUIT 190 PANEL C6-1 AND CONNECT TO CIRCUIT SHOWN. "A" PHASE (LEFT BUS IN PANEL) "B" PHASE (CENTER BUS IN PANE "C" PHASE (RIGHT BUS IN PANEL NEUTRAL EQUIPMENT GROUND ISOLATED GROUND WEST PORTION RECEIVED CITY OFTUKWILA MAY 1 4 1991 PLAN NORTH 1 ,40 01 , PERMITCENTER --- NO SCALE r " °�T BE &C NO SCALE 1 . / ENGINEERS L )088/120V BLACK RED BLUE WHITE GREEN GRN /YEL 1 EAST PORTION 11."F 480/277V BROWN ORANGE YELLOW GRAY GRN /YEL >,».u- ....:+.:s.- +,:,.eva+� • r ,�.,Y.k,4Kw`�:,4•uire�.nGgf>^'. NACN REF. NO. MACHINE PROPERTY NU. H.P. REMARKS �AR = � t/3 SEE HT Id -3 EF2 AIR BRUSH BOOTH EF -5 1/4 HP. ON ROOF ----, _ REVISION SSUE FOR 90% REVIEW SSUED FOR CONSTRUCTION LOBBY RELOCATION NSTALL UPS 1 11 c B4/28b,30c b 11c 25o 70 ] 12c 70 PNL 84 W.P. DUPLEX ON -- ROOF w /DISCONNECT ROOF MOUNTED CONDENSING UNIT t DENSAT E P, 1 /5HP 115V,30 ' C 1 /2 "C 60 � N C6/20,22 2 NEk1A /`°" 1 "C,3116 { 1 TYPE 1 8 4 / 13 a ,15 b ,17c 42c 04/42c _ 84/25o,17b,29c 29c I I - 24c 24c 24c 24c 26a �1 26o \ 1 2 9 c ►1� 84/24c,26a,130 ,3 14o 16b 16b 9b B4/20o,22b B4/8 1Ob, 2c rn 16b 11-111 16 18c 16b EF -3 HP. ON 13i HOA 6c� 10b 10b 10b 31o,33b,35c,37o C6- 1/19o,21b,23c IC C6Mo,21b C6/27b 2 39b a , 41c 39b 41c 39b1t141 1 tt5 41c 41c mow' t► 70 C6 /6c , 8a IG 9 IG C6- 1/13a,16b,1 13a C6-1/20,4b,6 C6- 1/8a,10b,12c 18c ►� 130 -- 3/4" FLEX* Iul IC6/23c,250 1Ob 12c 140 C6112c,14a 17c 190 IG 88/24C 3/4 "C -286 + 29c i RECORD DRAWING BY H.LEE J RB R.KENT RA -UGH DATE SYN REVISION 4.11.87 DEMOLITION DRAWING 6.75.87 F I DUPLICATION CENTER RE —MODEL 2.12.90 11.9.90 11.9.90 03.13.91 05.08.91 OFFICE ADDITION G REMOVE /RELOCATE A/C UNIT J4910112 -038 J191012 -062 APPROVED CI) SEE SHEET E503 FOR ADDITIONAL STUDIO LIGHTING ZDaf FACILITIES DEPARTMENT 4b 5" {4b 4 BR B8 /41c 314 "C -9/6 +1 GND 88/35c 3/4 "C -286 --- +1410 CND B8/310 4 3/4 "C -286 +1410 CND B8/39b 3/4 "C -296 +1810 CND I BS /37a 3/4 "C -246 +1 #10 GND PNL 88 B8 /10 4b GFI B8/33b 3/4 "C -246 +1410 CND ❑ AUBURN, WA. 98002 ❑ BELLEVUE, WA. 98008 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 0 PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 IL SEATTLE, WA. 98124 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED . WEST PORTION _ . EAST PORR 42 " IG 5c 2a Cr! 2 Q• B9 -1/2o, 1163] JP :1 0 16 In. INCN � Y• OE 6z 8G Lz 9? G,Z 4 7? CZ Z? lG 03 6l 8t Li 91 Gl lfl C { t Zl P. p(, 6 9 L 9 S +, C z t HY+ 0 IIIIIl ILIIIIIiIlIIIII! IIIl !fillililllllllllil!! Mill! i II) IiIIIIIIIiIIIIl ILlIIIIIIIlIilIIIII! lilllllil!; 1!! Ilillllilllill{ Illtiliilllllllllllllllln► IIIIE�!!! lilillll�I !IIIIII�{IIIIIIIIllllillllllil I " I IIIIIII I IIII1111111IIII I IIIIIl1 2 IlIIII1 I I I LI1 11III I1 1{ II II I { PI i i 4 5 6 7 8 9 10 1 1 MADE IN GERMANY 1 NOTE: If the microfilmed document is less clear than this . . notice, it is due to the quality of the: original. document. 15bIG 10bIG BaIG 3bIG 120G G 3bIG 12cIG 17cIG 10bIG C) 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. 6 FEEDERS TO PANELS SHOWN ON SHEETS E4 AND E500. 7. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 18 >SEE SHT [502 FOR ELEMENTARY WIRING DIAGRAM. f9)PROVIDE 24V CONTROL RELAY CONNECTED IN PARALLEL WITH L.V. LIGHTING CONTROL RELAY. SEE SH1 E502 FOR ELEMENTARY WIRING DIAGRAM. CONSTRUCTION NOTES 'PROVIDE *TREMOLO G4000 UNDER ROOM 140 WINDOW SILL WITH POWER AND COMMUNICATION SECTIONS. PROVIDE 120V RECEPTACLES, AS SHOWN, IN THE POWER SECTION. PROVIDE 120V OUTLETS FOR NEW DEMOUNTABLE PARTITION FOR ROOM 140 AS SHOWN. 4bIG 14oIG 20 1 G 10IG 5c IG 13a15bIG 3bIG 1a IG _.Il_11/1 I._-811L - 2X(1- 1/4 "C,14410 +1812G) - ---UPS REMOTE MONITORING PAN GND PNL B9 -1 n 1Y 1 t, a 1. ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOIED. 2. ALL WIRE TO BE 412 THWN /THHN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. E A ' PRASE ( L E F T BUS I N PANEL) "8" PHASE (CENTER BUS IN PANEL) " C " PHASE ( R I G H T BUS I N PANEL) NEUTRAL EQUIPMENT GROUND ISOLATED GROUND 4 LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. n ;_ L.J I I Lill I�1 89-1/10 89 -1 /Sb LJ AIR DRYER .65KW., 115V AMA GIMP+ (14 L 2a RECEIVED CITY OF TUKWIIA MAY 14 1991 2o WEST PORTION PAN NORTH "4 PERMITCENTER KEY PLAIN � Emu: NO SCALE " ENGINEER 120/908 VOLT POWER MOTION PICTURE AND TV AREA BUILDING 7•°33 GATEWAY BUILDING •4 120/2001. U7/480V BLACK BROWN RED ORANGE BLUE YELLOW WHITE GRAY GREEN GREEN GRN /YEL GRN /YEL EAST P OORRTIION .;\ yf " - r - , OFFICE ADDITION w cV 2 --LAMP BALLAST (TYPICAL 4 LAMP FIXTURE) rM r 1 1 BLACK (OFF) 1 -_.. RED (ON) 4 _ BLACK (OFF) 1 RED (ON) I- t GN - ---• -� OFF I L~ OUTER MAIMS DETAIL NOTES 1. PROVIDE SUPPORT CHANNEL SYSTEM WITH MATCHING HARDWARE AS REQLIIRED TO SUPPORT LIGHTING FIXTURES 12 FEET A.F.F. 2. ROUTE CIRCUITS THRU FIXTURES WHERE FIXTURES ARE CONTINUOUS. ROUTE CIRCUITS THRU EMT CONDUIT BETWEEN FIXTURES WHERE FIXTURES ARE NOT CONTINUOUS. SUE FOR 90% REVIEW ISSUED FOR CONSTRUCTION LOBBY RELOCATION BREAKROOM ADDITION 51.1.LLPHOT(4 99% RFV1 EW = 1— — 1 _, k - - -- INNER LAW' LICIff FIXTURES °---- --°- 2--LAM BALLAST 2-LAMP BALLAST Maim 1 -5/8" SQUARE X 12 GA STEEL SUPPORT CHANNEL (UNI ST RUT P1000 SYSTEM OR EQUIVALENT) - i - 1--LAM BALLAST (TYPICAL 3 LAMP FIXTURE) ` 277 V.A.C. I � LIGHTING CIRCUIT ----- 1 - •--- GROUND ; NEUTRAL --I--- PHASE BLUE �.._�.__ –_–I WHITE .–.,. ...............1 WHITE ` 14-1 -- 75 `/A 1 1. _..1.. ,�,._ 277/24V L _ -_ ._ _....._. _ _ __ __ _ __ N _J 1 XI MR - . _-- _._ -`1 W ALL SWI TCHES L_ WIRING DIAGRAM 1 1 Y P 10A ►_ L . V . L I C K I N G CONTROL i 10l 15 0 NOT TO SCALE AP "ROPED 14 277 V.A.C. JUNCTION BOX ABOVE CEILING b-• 24 V.D.C. JUNCTION BOX ABOVE CEILING 277 POWER EYEBOLT EYEBOLT CF NTERED VERTICALLY ON PURLIN (TYP) -- -3/8" THD ROD -- ATTACH TO ROOF FRAMING 08' -O" C . C MAXIMUM SPACING USING SWIVEL BRACKETS FIXTURE TYPE " SCALE 1J8 " =1' -0" -J it � - CORRIDOR CEILING LIGHT /,J.// ---1" SPACER • � FIXTURE TYPE "D" & "E" MOUNTING DETAIL PURL I N -- TO UPS LOADS BREAKER PANEL B1O ANIMATION LAB UPS INSTALLATION DIAGRAM r ROD HANGER PRE-DRILL AND CENTER VERTICALLY ON PURLIN (TYP) —THREADED ROD MOUNTING DETAIL CIRCUIT BREAKER ATE "NEL Zr 1 MAIM'. BYPASS BREAKER 3. PROVIDE SEISMIC BRACING GUY WIRES AS SHOWN ABOVE. FOR ROWS OF FIXTURES, PROVIDE (1) PAIR OF WIRES AT EACH FIXTURE. FOR INDIVIDUALLY MOUNTED FIXTURES, PROVIDE (1) PAIR OF WIRES AT EACH END OF FIXTURE. 1 UPS SUPPLY BREAKER urs srstEU� CABINETS , iMNT. BYPASS TRANSFER SWITCH 14 GUAGE STEEL WIRE SOFT DRAWN (ONE ON EACH SIDE) CHANNEL SUPPORT STRUCTURE --"-----'%'NN\c,----' . r'� FIXTURE. 3 -T URNS MI NI MUM ( TYP) /-SUSPENDED CEILING !LC/111_i i' -WALL TRACK HEAD FIXTURE TYPE "F" MOUNTING DETAIL fo�Gr,� FACIL1TlES DEPARTMENT 1 3 7 (2) T5 TUNGSTEN (1) 150W R -40 FLOOD (_) 9W COMPACT FLUORESCENT LAMPS (2) 34W HPF,CBM, F40T12 /RS U- SHAPED WARM WHITE (2) 5W /T5 COMPACT FLUORESCENT (2) -34W F40T12 /RS WARM WHITE (1) -250W QUARTZ PAR PER HEAD (2) -34W F40T 12/RS WARM WHITE HPF,CBM, ENERGY SAVING HPF,CBM, ENERGY SAVING ENERGY SAVING TRIGGER START HPF, CBM ENERGY SAVING (4) -34W F40112 /RS WARM WHITE (3) -34W 140T12/RS WARM WHITE (3) -34W F40T12 /RS WARM WHITE 65 WATT R30, GE# 65R /FL /M1 HPF, CBM ENERGY SAVING HPF, CBM ENERGY SAVING HPF, CBM ENERGY SAVING HPF, CBM ENERGY SAVING HPF, CBM ENERGY SAVING (4) -34W 'HPF, CBM F40112/RS ENERGY WARM WHITE SAVING 277V 277V 277V 277V 120V HPF, CBM ENERGY 277V SAVING 277V 277V 120V 277V 120V 277V 277V 277V LIGHTOLIER LYTESPAN BASIC 120V 6000 SERIES TRACK LAMP #6337 OFFICE ADDITION JOB NO. 87081 DWG. NO. 7.33 -E501 E501 SYMBOL H 0) 48 "X24" X4 -3/8" (MIN DEPTH) FLUORESCENT REC. TROFFER W /ACRYLIC A-12 LENS 48 "X 24 "X4 -3/8" (MIN DEPTH) C FLUORESCENT REC. TROFFER 124 W /PARABOLIC SHIELD(SEE CAT NO) 0 5. ❑ AUBURN, WA. 98002 ❑ BELLEVUE_, WA. 98008 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 11 SEATTLE, WA. 98124 48° FLUORESCENT INDUSTRIAL W /PORCELAIN REFLECTOR 6 "X6 "X48" FLUORESCENT INDIRECT UPLIGHT 6 "X6"X48" FLOORESCENT 1ND1RECI UPL1GHT WITH ASYMMETRIC REFLECTOR DESCRIPTION INCANDESCENT TRACK SYSTEM WITH WHITE HARDWARE 12 "X 49" FLUORESCENT WITH S CE ONE PIECE 1 NJ ECT 10N- IIOLDED MOUNT ON PRISMATIC ACRYLIC DIFFUSER CEILING EXIT SIGN WITH DOWN LIGHT & EMERGENCY POWER KIT. SATIN ALUMINUM HOUSING WITH GREEN LETTERS EMERGENCY UNIT WITH TWO HEADS BATTERY PACK INCANDESCENT DOWNLIGHT WITH SPECULAR BLACK ALZAK OPEN REFLECTOR EMERGENCY DOWN LIGHT WITH BATTERY PACK & CLEAR ALZAK REFLECTOR 24 "X24" X4 -3/8 "(MIN DEPTH) FLUORESCENT RECESSED TROFFER WITH ACRYLIC A-12 LENS SIGN LIGHT WITH SINGLE FACE, RED LETTERS & WHITE FINISH 48" FLUORESCENT WITH CLOSED TOP AND ACRYLIC LENS (WITHOUT SWITCH OR RECEPT.) INCANDESCENT TRACK SYSTEM WITH WHITE HARDWARE 48" FLUORESCENT INDUSTRIAL W /WHITE ENAMEL REFLECTOR, 5% MIGHT, & WIRE GUARD 48" FLUORESCENT INDUSTRIAL W /WHITE ENAMEL REFLECTOR, 5% UPLIGHT, & WIRE GUARD 48" FLUORESCENT WRAPAROUND W /WHITE ENAMEL FINISH AND PRISMATIC ACRYLIC DIFFUSER INCANDESCENT DOWNLIGHT W /MATTE BLACK STEPPED BAFFLE AND THERMALLY PROTECTED F RAM.E. =1 N 11ft0 48" FLUORESCENT WRAPAROUND W /WHITE ENAMEL FINISH AND PRISMATIC ACRYLIC DIFFUSER 24 "X48" RECESSED FLUOR. TROFFER SPECIFICATION PREMIUM GRADE FOR LAY -IN GRID. W I T H 1 -1/2 X i --1/2" SILVER PARACUBE --TYPE LOUVER 24 "X48" RECESSED FLUOR. TROFFER SPECIFICATION PREMIUM GRADE FOR LAY -IN GRID. WITH 1 -1/2 X 1 -1/2" SILVER PARACUBE -TYPE LOUVER �.•� INCANDESCENT TRACK SYSTEM WITH MATTE WHITE HARDWARE 1 1 LIf,NTING FIXTURE SCHEDULE mnt MOUNTING BALLAST OI.TAGE CATALOG NUMBER SUSPENDED ON CHANNEL SUPT . SYST . LAY-IN f -BAR LAY-IN T -BAR WALL MOUNT IN CONTINUOS RUNS W11H OFF SET BRACKETS WALL MOUNT IN CONTINUOS RUNS W/OFF- SET BRACKETS WALL MOUNT TOP OR BACK MOUNT SURFACE WALL MOUNT RECESSED IN CEILING RECESSED IN CEILING LAY-IN T -BAR FLUSH MOUNT IN WALL WALL MOUNT T IGHT TO CEILING UNLESS NOTED OTHERWISE CEILING MOUNT TRACKS ARE PART OF CEILING GRID SUSPENDED ON CHANNEL SUPPORT SYS. SUSPENDED ON CHANNEL SUPPORT SYS. SURFACE MOUNT ON CEILING RECESSED IN CEILING SURFACE MOUNT ON CEILING LAY-1N T -BAR LAY -IN T -BAR 1'9" FROM CEILING OR ON CEILING LAMPS (2) -34W 140T12/RS WARM WHITE (3) -34W F40112/RS WARM WHITE (3) -34W F40T12/RS 5000 °K (2) -34W F40T12 /RS WARM WHITE (1) -34W F40T12 /RS WARM WHITE (1) -250W QUARTZ PAR PER HEAD (2) -34W F40T12 /RS WARM WHITE (2) 4W /T5 FLUORESCENT (1) -150/ R40SP (4) -34W F40T12 /RS WARM WHITE NPF,CBM, ENERGY SAVING 277V ENERGY SAVING HPF,CBM, ENERGY SAVING TITLE 277V 120V 277V 120V 277V 277V REVISION 3.10.88 2.23.90 1.09.90 5.08.91 REVISION E STILLPHOTO - ISSUED FOR CONSTRUCTION F INSTALL UPS DUPLICATION CENTER RE -MODEL H OFFICE ADDITION J891012 -062 APPROVED 0 IB THS INCH 1 2 , 5- .. rte.'. -. .:..f .,. . t;' }; � • � .. L..-; .. .. . -._ •.. 1111 1111; 111I111I111I111I1ITHIIIIIIIIIIVIHIjiIil IP111111111111111111111i1i (i11111111111111111i11j11!`!1T 3 4 5 6 7 NOTE: If the microfilmed document is less clear than this notice, it is due to the duality of the original docuaent. ' 1IillllIIIll !II�I�II!III!IlIII!�!�illIlill , 10 11 >"OR 12 pH 6 se Le 97. 5z VZ CZ ZZ tz O3 61 81 Lt 91 91 tiL Ct zt a pi. 6 s t, 9 5 i C z t $r II( Il�illllllll�l! lll I�IIIIIII! I�IIIIIIII! �IflIIIIII�IIIIIIIilflll�li !!`I!i!�II! Lill!! �i! lI�III; �IIiI�II�IIIIII�► II! IIIII�IIII�lI! I�IlI! Illli�ilillllll�! iliflllllll! I�IIII�iiillllli�lllIII!! I�IIIllllfl�lllllllll�Il!IIIlII II I �' ` ''' ! II p '. Ll�llllll.Il II. III. uI�i�! �IIlI��IIIllllflllll�lllllllll�lllillllllilil� ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY BLDG. 1 -033 S HIE L D: I NJ E CT I ON -lOL DE D PARABOLIC POLYSTYRENE PLASTIC LOUVER, 1/2 "X1 /'2'X1 /2" SQUARE CELL WALL MTD W /1" SPACER BETWEEN FIXTURE & WALL EXCEPT Al MTC BRACKET SE'" DTI 3 THIS SHEET WALL MTD W /1" SPACER BETWEEN FIXTURE & WALL EXCEPT AT MTG BRACKET SEE DTI 3 THIS SHEET PART- LITHONIA CAT# HEAD TCR -40 /WH TRACK 8' T8 /WH END FEED TA -1 /WH MARCO SINGLE FACE - X25916 DOUBLE FACE- X2595G L, AD- CALCIUM BATTURIEL. LITHONIA ELM -2 LiGHTOLIER CAT. NO. 7707-A2 LITHONIA CAT. NO. LE- RFC- 1A277EL MARCO X2599R/F28 DAY -BRITE EQUALITE 45242 -1 LITHONIA WS240 WILLIAMS 2922 OR APPROVED EQUAL LIGHTOLIER LYTESPAN III WITH 7151 HEADS -WHITE LITHONIA ;I`EJA240277ESWG4 OR APPROVED EQUAL LITHONIA 8EJA440277ESWG6 OR APPROVED EQUAL LITHONIA 4AW340A277ES 277y OR APPROVED EQUAL LITHONIA #RB -3 /0 OR APPROVED EQUAL LITHONIA 4AW440A277ES OR APPROVED EQUAL LITHONIA #2SPG340PC2S277ES OR APPROVED EQUAL LITHONIA #2SPG440PC2S277ES OR APPROVED EQUAL SEE DETAIL 2 THIS SHEET RECEIVED CITY OF TUKWILA MAY 1 4 1991 PERMIT CENTER BE &C BACK MOUNT LIGHTING SCHEDULE & DETAILS ELECTRICAL MASTER GATEWAY REMARKS PROVIDE W/ EACH FIXTURE (1)2 -LAMP BALLAST & (1)1-LAMP BALLAST PROVIDE W/ EACH FIXTURE (1)2-LAMP BALLAST & (1)1 -LAMP BALLAST OFFICE COVE LIGHT DUAL SWITCHED 0 R RTUR "V E u ONE BALLAST CONTROLS TWO FIXTURES SEE DETAIL 4 THIS SHEET DOOR STYLE -FLAT TOP MOUNT - -ARROW I NDICATES SECT I OR NORMALLY OFF WITH LEAD-CALCIUM BATTERIES VESTIBULE LIGHT NORMALLY ON WITH LEAD- CALCIUM BATTERIES SIGN SHALL READ "RECORDING" SEE DETAIL 2 THIS SHEET SEE DETAIL 2 THIS SHEET FIXTURE LISTED FOR USE WITH 100/A19, 150/A21 , 150/R40, AND 150/PAR38 LAMPS s. I r.91 L co