Permit 6706 - Swanson Residence - Addition and Reroof
6706 91-266 swanson david sunwood condos addition 4616 south 124th street Permit 6706 - Swanson Addition . - • • l „ - g: s • ' year 1988 SETBACKS: N - S - E- W - FIRE PROTECTION: rm Sprinklers De tectors x N/A O O UTILITY PERMITS REQUIRED? Oyes x No O (troug Public works) ZONING: BAR/LAND USE CONDITIONS? O Yes 0 No CONDITIONS (other than those noted on or attached to permit/plans) CITY OF TUKWILA Dept. of Community Development- Building Divisio 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 DATE ISSUED: BUILDING / - PERMIT NO. U/ 70 ((2 SITE ADDRESS PROJECT NAME/TENANT Swanson, David TYPE OF U New Building J Addition U Tenant Improvement (commercial) U Demolition (building) Li Grading/Fill WORK: Q Rack Storage © Reroof 0 Remodel (residential) O Other: DESCRIBE WORK TO BE DONE: Add 216 square feet to single- family residence, replace windows, install new siding, and reroof entire home. ADDRESS CONTRACTOR ADDRESS ter' „digiiiiili 4616 S 124 David C. & Merle J. Swanson 4616 South 124th, Tukwila, WA D. J. Sweet Construction 7503 South Taft, Seattle, WA WA. ST. CONTRACTOR'S LICENSE # DJSWEC *099MT ARCHITECT ADDRESS TO APPROVED FOR ISSUANCE BY: PRINT NAME: SIGNATURE: ---rte BUILDIF..G PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) FEES BUILDINC:.I?ERMIT;FEE ::..3 26:.00 ( ( f • PLAN;CHECK`.FEE :8:2 00:: < 00 PLAN CHECK NO.: SUITE # VALU 0 CONSTRUCTION - $ CODE COMPLIANCE OCC. D SQUARE FEET OCC. LOAD SQUARE FE SQUARE FE OCC. LO 0 TOTAL S.UA:EF • OCC. OA' SQUARE E OCC. O BUILDING OFFICIAL I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of lair and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. ek This permit shall, become null and void if th work r issuance, or if'the work �s suspended oraband CERTIFICATE OF OCCUPANCY NO. of commenced within 18 day from th datE o r;a period of 180 da fr t he la in spe ct ! • DATE: � COMPANY: ( DATE ISSUED: 91 -266 PHONE EXP. DATE PHONE DATE: 7 ... y _ 10,699.00 762 -8568 ZIP 98178 772 -5555 ZIP 98178 8 -17 -91 ZIP ASSESSOR ACCOUNT # 017900 - 1010 -01 TOTAL O C L PERMIT NO. CONTACTED kt -- • f3�i n e cx )D 61 I BY W ^ HT(---- DATE READY DATE NOTIFIED PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING 3 50 3RD NOTIFICATION BY: ) C C BUILDING VELNIIT APPLICATION TRACKING PLAN CHECK NUMBER INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET 000. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCC. LOAD DEPARTMENTAL REVIEW "X" in box Indicates which departments need to review the project. RTME:NT J.M l BUILDING - initial review O FIRE P LANNING LAN N I NG��r,' O PUBLIC WORKS O OTHER BUILDING - final review REVIEW COMPLETED PROJECT NAME SITE ADDRESS (ROUTED) INIT: 7 /e-10A REFERENCE FILE NOS.: INIT ,MINIMUM SETBACKS: N- 0 S- 3Q E - 7. 5 W - 7. 5 UTILITY PERMITS REQUIRED? Yes (�No .,W/° INIT: INIT: 7:47/ P P; INIT: Sw■rlon, bmiJ L- c0Ro s ia4-44. sr CONSULTANT: Date Sent - Date Approved - FIRE PROTECTION: Sprinklers FIRE DEPT. LETTER DATED: ZONING: PUBLIC WORKS LETTER DATED: TYPE OF CONSTRUCTION: v� SUITE NO. Detectors INSPECTOR: N/A BAR/LAND USE CONDITIONS? ■ Yes UBC EDITION (year): SITE ADDRESS SUITE # b 1 ? S i L I 7 h T(. (WI ' L4 ( VALUE OF CONSTRUCTION - $ 10_, (c lq .00 PROJECT NAME/TENANT 4 3waf ton , mul ASSESSOR ACCOUNT # n1 o0 - I O I O~ O l TYPE OF U New Building ,,.._ Addition U Improvement (commercial) De olition (building) WORK: 0 Rack Storage IQ'Reroof U'Remodel (residential) O Other S i DESCR E WORK T C BE DONE: x 2.7 ' et,.CiAlit,6 .-s . BUILDING USE (•ffice, warehou k, etc.) . 1 S A '"�1 — d)U Q 1�"■.X3vni—_, NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? Vio U Yes IF YES, EXPLAIN: L SQUARE FOOTAGE - Building: in Tenant Space: 97q Area of Construction:01/4 q WILL THERE BE RAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? No 0 Yes IF YES, EXPLAIN: PROPERTY OWNER ocLAAd C , 4 yq � Cir2Ln&birS1 PHONE q a .35.,„g ADDRESS L-{ ( i (a S is y —T Qom„ LOA- Zl �8'/7 F CONTRACTOR --�M F .. �.., PHONE - u Sa s ADDRESS p- 3 s , ( 4 SaaoA, 0A- ZIPFg/ 72' WA. ST. CONTRACTOR'S LICENSE # Ai e F l 1c f 1 b0 EXP. DATE $215 PHONE ARCHITECT ADDRESS ZIP ::. ; • >:CE T1I�Y O RR T�fif�T �P�V� t�EAE�: A�i� :<:EXAM I T IZ D TO A P Y t . THIS RS ..MIT::::::,. < ; _» BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE t Q C ���- DATE (Q .40 /9/ PHONE �' iaz $sSs - -- E PRINT NAME A Le sr Q()Qe� ADDRr SB --0 S '..7 • -1 Se : CITY.1,t.iF .zS'l 7g PHONE CONTACT PERSON 54mcC... CITY OF TUKWiLA Department of Community Development - Building 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 APPLICATION MUST BE FILLED OUT COMPLETELY Y DATE APPLICATION ACCEPTED BUILDING' PERMIT APPLICATION Division w . c . I . o UILDING> PERMIT`FEE> PLAN .CHECK FEE':'<'< BUILDING :, SURCHARGE' APPLICATION SU' 1MITTAL In order to ensure that your application is accepted for plan review, I. c•%.ce make sure to fill out thn appli'hlion completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide mwiri, detailed information on application and plan submittal requiran Application and plans must be •:-ompiste in order to Lo accepted fur plan VALUATION; Of- ? STRUCTION Va'uation for new construction and additions are calculated by the Department of Comr►ksPity I,mvelnpment prior to a »plication submittal. Contact the Permit Cc ...:+''atnr at 431 -3670 prior to submNtyr,j tipr ilicatioi. In all cases, a valuation amount should be entered by the applicant. h his figure will be re<<Vw: ;E ? :a sulr' ,, -1 possible revision by the building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or cc; ^t•n't.r IIr.ot ; zd by the State of Washington, a notarized letter from the property owner authorizing the agent t:. 5uuinit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations: The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION EXPIRES _ -ate a COMMERCIAL : NEW COMMERCIAL SUILtRNOS/ADOITIONB Completed building permit application (one for each situ •Assessor Account Number hno seta (?):of the folbwin � Speafiaaticxtg Structural calculations. stamped by a Waahktgton state I engineer Sails; report stamped. by a Washi • pographical survey! • Energy calculations stamped by a •Washington State iieenf • engineer or architect epee description;` < Wo�Scing drawings, : stamped b a 1Alashinglon Star I architect; which include Architac�ural dfawingc , structural drawings Mechanical drawings.: Elevations Civil drawings Laiidacape p Completed utility permh application • sets;of:civlt :drawing NOTE See utdhy permh application and ch eckdst tor: submlftal requlremonts tonstao iiaansaf heigh t NTENMAISATELLIT DlBN 0.itit0l0100 lwikl&ii perm Assessor A ccount: N umb+ sus showing wail aonatfttcdon end mo ih s Mont for 1 oelUn ku iad s tamped by si V1tashington Stater �aei I be • i f sbttsrittrai work is OQ be darlA (2 fy wwlt Is fa lea pbt>a, eui7ntic s t o: a d rp Cprnplet+ad twlidtrlq' permit *ppiicnn (one h'tr aactk abuaa �• Asso;sor Aoc ount Nu Namadvv describin existing roof, matodai being removed; ;mate{lal ... istalied ,.:.. NOTE:. A c ertification letter Is required prior to final inspectio n . oft of the permit yida`utiliry perm appr RACK STORAGE Completed building permit application Assessor Account Num wb (2) Seta of plans , loci Building floor, plan shows pike :space whore rack xit doors enslons.of ail ................. ..................... anent space flout plan showing rata exits . NOM Include dimensions of, rants and exit ways on plan truotural calculations stamped by a Wachmptgn •State; iiceri engineer (rack starega 8 and over :: RESIDENTIAL - S`iBMITTAL CHIC .LIST NEW SINGLE.FAMILX DWELLINGS/ADDITItN $ Completed •building permit application (one for eac h structure; ;Legal description Assessor :Account Num wa sets (2) of warWng, drawings, which)► ci Site. plan =.�..�. (Q plan sh w cio ethy int �cedon Foundation plan brdude •access b br aFrtO stwwlrrg ;?. Floor. plan width and iarryih of aoosas.) `Roof , .Building elevations(all.views . Building cross - section : • Structural framing p iano ; • • • Washington State Energy Cnde •data Completed utility permit application •• Six (6) sets of site pians showing NOTE : Building site plan and utility site plan may lea combinod S utility permit application and chocldist fog specific submiaat vqulrpmonts.' • • Addtional topographical and soils information may required i unique • efts condiNon+� ' COltft>VILRCfAL;Tfa?tAttC IM V.EME 1 Completd buildup peanut apps tenant), Comp leted building permit apps Asses Num • Nacradve:descnbing exisI1 ' material being installed ::.NOTE. f. oartildcgfion tarter Is :required pact to Neal >nspeodor► anti sign oil of the permit: • removed an d IX" PERMITS TO PWD APPROVED PERMIT NUMBER APPROVED PLAN /LETTER DATE ISSUED S4-e_ U-- i ti -i�t, Channelization/Striping/Signing Curb Cut/Access/Sidewalk Fire Loop/Hydrant Flood Zone Control Grade/Fill Hauls , Landscape Irrigation Moving an Oversized Load Sanitary Side Sewer Sewer Main Extension (private) Sewer Main Extension_ public) Storm Drainage Water Main Extension (private) Water Main Extension (public) Water Meter (exempt) Size: No.: ❑Deduct ❑ Water Only Water Meter (permanent) size: No.: Water Meter (temporary) size: No.: Other: Other: RECEIVED TYPE OF REVIEW TO PWD APPROVED REQUESTED COMMENTS Irr co S4-e_ U-- i ti -i�t, (Q --� c. i PLAN CHECK NUMBER -atoo ROUTING PERMITS REQUIRED PROJECT NAME SITE ADDRESS UTILITY P' O "ECT TRACKING CHECKLIST SUITE NO. 4 lv l lt) 5 1 Q L1 � Swar150f , I k\J i CONDITIONS OF PERMIT ISSUANCE OR FINAL SIGN -OFF OF PROJECT I HEREBif: CERTIFY THAT i HAVE READ THIS AFFLICATION AND KNOW THE SAME ME TO BE TR IE ANLII CORRECT. Applicant/Authorized Agent Signature: Z Contact Person e n (print name):' Address: --f Print Name: p ec. `I Date: 2o t ci Phone: 21 5 Phone: Date Application Accepted: Date Application Expires: ) a_, G� �. CITY OF TUKWILA Central Permit System - Engineering Division 6300 Southcenter Blvd., Tukwila, WA 98188 Phone: (206) 433 -0179 PROJECT Site Address: 9 / S INFORMIATION Name of Pro ect: Property Owner: 'bR L O C fl' f? L sw A to Sc,►o Street ,► rel Engineer: Street Address: Contractor: M Street Address: ) ta:), 3 S City / State/Zip: Se, Lc),j- 912 King Coy Assessor Account Number: / 4 - 0/ 7? o o °- Jo Jo -- O S PERMITS > ;` ❑ Channelization/Striping/Signing REQUESTED ❑ Curb Cut/Access/Sidewalk ❑ Fire Loop/Hydr. (main to vault) – No.: ^ Sizes: ❑ Flood Zone Control ❑ Grade/Fil cubic yards ❑ Hauling ❑ Landscape Irrigation ❑ Moving an Oversized Load ❑ Sanitary Side Sewer – No.: ❑ Sewer Main Extension Private ❑ Public ❑ WATER: METE . DEPOSiTt;<> < REFUND /SILLI Name: Street MONTHLY Name: SERVICE < >> BILLINGS<:Yp;'. < <:< Street ( rILITY PERM"; P ?PLICATiON a 0 PLAN CHECK q NUMBER: / 2 4/ tG' 7 '4.w .Q A- 5 /7 Cit /State /ZI . : S rvt Phone No.: Cit /State/Zi . : Phone No.: ' Phone No.: City /State /Zip: a ❑ Water ❑ Sewer El Metro ❑ tandb >:DESCRIPTION OF: PROJECT Single - Family Residential Phone No.: City /State/Zip: ❑ Multiple - Family Dwelling El Hotel ❑ Duplex El Apartments ❑ Other: No. of Units: ❑ Motel ❑ Tri.lex ❑ Condominiums El Commercial/industrial ❑ Office El Retail ❑ Warehouse ❑ Manufadurin Phone No.: % 8 S(,,,q 7 Z SS 5 ❑ Storm Drain ❑ Street Use ❑ Water Main Extension Private ❑ Public ❑ ❑ Water Meter/ Exempt:– No.: — Sizes: Deduct ❑ Water Only ❑ ❑ Water Meter/ Permanent – No.: — Sizes' ❑ Water Meter/ Temporary: – No.: — Sizes• ❑ Other: El Church El School/College /University ❑ Hosaital El Other: MISCELLANEOUS' ❑New Building rd" Remodel/ Square footage of original building space: og3 INFORMATION Square ddition ,: >.:. Footage: 02 /b Square footage of additional building space: a /& King County Assessor's valuation of existing structures: $ 5 / 5 0 Valuation of work to be done: $ -61) I b 0 09/18190 SUBMITTAL_ C !(LIST All site plans shall be provided in one submittal for review by the Public Works Department. Six (6) sets of plans stamped by a licensed engineer are required along with this application completed and signed by the applicant's representative. The following information is necessary for Public Works Department evaluation and approval of site plans: • All utility construction is to meet the City of Tukwila Standards • Indicate scale of drawing and show north arrow • Identify location by address or distance to nearest intersection CURB CUT /ACCESS /SIDEWALKS/ CHANNELIZATION /STRIPING /SIGNING O Dimensions O Type of surfacing - asphalt, crushed rock, etc.(and thickness) O Percent of slope or runoff direction O Size of curb cuts/location O Vehicular and pedestrian traffic facilities, including signing and striping, wheel chair ramps, curb cuts FIRE LOOP /HYDRANT O Type of pipe O Size of pipe /location O Location and type of all valves O Type of bedding and backfill materials /percent compaction O Distance from structures, storm and sewer facilities at minimum separation O Location and size of thrust blocking FLOOD ZONE CONTROL (Requirements are under Flood Ord. No. 1462 and can be obtained from the Public Works Dept.) O Lowest finished floor elevation O Contours and elevations per National Geodetic Vertical Datum LAND ALTERING (CLEARING, GRADE AND FILL) O Contour map (2' Intervals) showing existing and proposed contours O Estimate of yardage, both cut and fill O Erosion control plan HAULING O Copy of Certificate of insurance coverage (minimum $1,000,000) O $2,000 bond made out to the City of Tukwila for property damages caused by activities O Route map LANDSCAPE IRRIGATION O Location of DSHS approved double check valve O Type of pipe - copper, high density molecular plastic, ductile O Size and depth of pipe O Size of meter O Location and elevation of meter box (water meter - permanent and exempt). Clearly show whether tap is on main or domestic service O Location and type of tap O Type of bedding and backfill materials/percent compaction MOVING AN OVERSIZED LOAD O Copy of Certificate of insurance coverage (minimum $1,000,000) O $5,000 bond made out to the City of Tukwila for property damages caused by activities O Business License with City of Tukwila O Route map SANIT lY cr - `E SEWER O Typ,... pipe 'i•. ,ncrete, PVC, etc. O Size of pipe/location O Percent of slope on pipe /length of run O Connection point(s) to public O Location of cleanout(s) and test Tec(s) O Type of bedding and backfill material/percent compaction O Invert elevations at structures and Junctions SEWER MAIN EXTENSION O Type of pipe - concrete, PVC, etc. O Size of pipe /location O Percent of slope on pipe/length of run O Connection point(s) to public O Location of cleanouts O Type of bedding and backfill material/percent compaction STORM DRAINAGE (including existing topography and proposed grading and surfacing) O Type of pipe O Size of pipe O Percent of slope/length of run O Location of all structures O Square footage of area to be drained, Including roof area O Bedding material for pipe O Invert or flow line elevations STREET USE O Complete description of proposed activity O Map with address and outline of limits of activity relative to public right -of -way and easements O Proposed traffic control/detour (per Manual of Uniform Traffic Control Devices) O Proposed schedule (times and dates) WATER MAIN EXTENSION O Type of pipe O Size of pipe O Hydrant type and locations O Valve type and locations O Connection point(s) to existing system O Type of connection - live tap, tee, etc. O Location and size of thrust blocking O Size and location of mains, including elevations (profile) WATER METER - EXEMPT O Diagram of domestic system/tie in of exempt meter O Number /account for existing domestic meter O Size and type of material of meter and service O Site address WATER METER - PERMANENT O Type of pipe - copper, high density molecular plastic, ductile O Size and depth of pipe O Size of meter O Location and elevation of meter box (water meter - permanent and exempt) O Location and type of tap O Type of bedding and backfill materials/percent compaction WATER METER - TEMPORARY O Address and hydrant location O Size of meter O Estimate of quantity and schedule fter t o Pub c o s Department has comp et :. t e r rev ew an t e p ans are approv , t e app t w not by letter concerning the necessary permits and requirements; an approved set of plans will accompany the letter. If the plans are not approved, the applicant will be notified by letter of necessary resubmittal requirements. TO: FROM: DATE: CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUKWILA, WASHINGTON 98188 Svr�e Q$, 1 SUBJECT: Fa C Rer i-1- MEMORANDUM flan Ck�ec1 tea, o n. SUr Chora.sz _ 1 1. 50 1 a 5� .' C PHONE p (206/ 4331800 Gary L. VanDusen, Mayor akuk. Con n i ba o Su i U aAucl.�ion '1)0o40., R:pri I , qq a).W&W rl l5 (0 x CDI-1.15 =- 4 1o) Qo` . L1 O r 3°' (1. 53 a co • • Io, ( rO roe e ype o ns. : Address: /2 0/ 2 9 ' Date Called: Special Instructions: : CO . Date Wanted: ..., / — am. On. Requester: Phone No.: 7M.7 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: I ()cep% No.: • INSPECTION RECORD Retain a copy with permit frit Approved per applicable codes. 0 Corrections required prior to approval. .• • 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule feinspection. 0. " 2 0 6 431 -3670 • PROJECT: / ilk PERMIT NO. ' 70 SITE ADDRESS: i / Z- DATE CALLED: f 6 a TYPE OF INSPECTION: G1/VV -4-41 DATE WANTED: ' (� =. - 9 • +� SPECIAL INSTRUCTIONS: REQUESTER: jV ' • '� PHONE NO.: (e - -� 5562 INSPECTION RESULTS /COMMENTS: ,t V i ■ ...,ice / A , .. i INSPECTOR: £2tJ ... ".. - _,I DATE: 9 .2' -et, vklTic :"+s:rc�n CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 tlxartee't•. }y:r x.v4.1' • „ua �ac.raM: rase,, w�i�� '�'•,l'�.��'�':�`rs£�'�a�::.. INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 Permit No. _ Date t 7--V/ • CITY OF TUKWILA Building Division 6200 Souihcentar Blvd, Tukwila, WA 88188' 433 -1845 • Job Address CORRECTION NOTICE The following items are found to be in violation of Ordinance eJci and shall be corrected. / 7 7 . L'1 / f ►lr t G l'� �?¢�G�+ Signed ul vi 3 -g of n„i/,, +✓s f1 b. i•i 4 ` d 1224'`4 4- 0704-if uiiding ottici"al /Inspector A/.i. ' ifJ!'i_ T: 7"'_. 1.i i J_. "I.. Ai PROJECT: / PERMIT NO. 6 D‘ , _„ -. _ : n. ---- SITE ADDRESS:4/6 / 1 14 /0 DATE CALLED: -- :r �"I'P A IMP TYPE OF INSPECTION: ma y- -c.i z. • DATE WANTED: REQUESTER:_ / SPECIAL INSTRUCTIONS: ItS mac. —a. A • /2) ec•/x2 u.e.e. " PHONE NO.: 7C . INSPECTION RESULTS/COMMENTS: ,, /. ./..... ., l INSPECTOR: , - - aus DATE: -- ' ,, ILLTAK 7; CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 (r.:;c�. •ar.h vaW �d0.r;+uu.^a....e „,..yn'�..r z+. \� +W.i INSPEC710k RECORD 6300 Southcenter Boulevard -- #100 Tukwila Washington 98188 PROJECT: ( 4) PERMIT NO. 76(0 SITE ADDRESS: i , , • DATE CALLED: DATE WANTED: REQUESTER: i - c9 q SIONnat " TYPE OF INSPECTION: L-411411..../.1 SPECIAL INSTRUCTIONS: PHONE NO.: , , o INSPECTION RESULTS/COMMENTS: 04 c.0 c 77 r_ e _ --i--- INSPECTOR: .15:770 i . _.4. TY, DATE: IQ.-- An.- g/ CITY OF TUKW1LA Dept. of Community Development - Building Division Phone: (206) 431-3670 C INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 Permit No. 6700 Date �...' CITY OF TUKWILA Building Division 6200 Soulhcen(or Blvd. Tukwila, WA 98188 433 -1845 Job Address _ — -c ' /2/r CORRECTION NOTICE The following items are found to be in violation of Ordinance bi and shall be corrected. ��� 4•l • r fro 0I p1 4 Signe Building 0 icial /Ins.actor PROJECT: j , U7jM ��y DaAPt_0C PERMIT NO. 6T SITE ADDRESS: i J - _ (. • DATE CALLED: - cj - 7 I TYPE OF INSPECTION: Y Ic DATE WANTED: 6 — ,9 ' :, -1 SPECIAL INSTRUCTIONS: REQUESTER: Q Z� PHONE NO.: `7C`v 2 INSPECTION RESULTS /COMMENTS: z r ,t / INSPECTOR: r Pve J DATE: CL-- `"' C 'I/ i i.3b:..,ru!:...nr..a•.M.i.z.� CITY OF TUKVV 1LA Dept. of Community Development - Building Division Phone: (206) 431 -3670 • INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: a, Shy y-N re S ‘. c.A. PERMIT NO. 6 70 (p SITE ADDRESS: c{(p CPO .S. /2-Cr DATE CALLED: 2 • (b q 1 TYPE OF INSPECTION: tilrl 0.nfrt+d y.. DATE WANTED: �r - L -' L SPECIAL INSTRUCTIONS: e. 4{ _ REQUESTER: N.. S . " r PHONE NO.: 1 g 53y INSPECTION RESULTS /COMMENTS: ,.) 4 atsy•-c-ut.7-... - tvir (c...c.a..,+ INSPECTOR: — DATE: Ir • 2 - - 1 , '), •!; 1lA:Y.'1 ":. Vr{ tttt0 1: n m.r.e+M.a:N+nar» „rsn�...n.: 4-1.4,1, ».,nrA+n +...rn.N , rnr. :u :•.r•.t.x .a.wn.:.,.� e,...... CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 T� +u .ss °YCfr INSPECTION RECORD 6300 Southcenter Boulevard #100 Tukwila Washington 98188 0 . I CITY OF TUKW1L APPROVED •JU S 1991 AS BUILD G ilvi 'Ok e t„o 1. 7 t SEPARATE PERMIT AND APPROVAL REQUIRED 7 ou a ;1 WPJ C' I ELeCigICAL FILE O Y I i`i lit 0 o 4 %. ,8 ,9I TL 11'4 it • I understand that the Ch k approvals are 7( &ubiect to errors and omission. and approval of plans does not authorize the vi gLany ..... adopted cOdeOr Receipt of contractor's copy of approved plans acknowledged. By. Date 't-7 7 Permit No . 14 , QI • RECEIVE CITY OF TM< ILA JUN 2 8 91 PERMITCEN ER RECEIVE CITY OFTUKWILA JUN 281991 PERMIT CENTER CITY OF TUKWILA APPROVED 8 1991 • t , CITY OF TUKWILA APPROVED 'JUL 1991 81 ILDING DIVISION • r r r CITY OF TUKWILA APPROVED JUL ; 1991 � r B LDING DIVISION :1• , 7/ r ■ R ECEIVED' CITY ©F TUKWILA r� JUN 2 8.1991 PERMITCENITER O • 4l Lr � •I• Ct ,p <3 • I - i( c., 7 tA. s . PER IVIIT CENTER FtEcitvEa. CITY OF TI 1KWILA , JUN 2 8 1991 3 CITY OF TUKWILA APPROVED JUL 1991 BUILD G DIVISION I ••.,„ • ". • . .• • . • • . • (;p) OP C VAWA. S (10 1 F CITY OF TUKWILA APPROVED 'JUL 8 1991 RECEIVED, CITY OFTI IKVVILA JUN 2 8 199 PERMIT CENTER , • 0 i f) • ,11 t r ' 0 . r ' i. 7'• . I, - -f RECEIVED CITY . OFTI IKWLA JUN.28 PERMIT. CENTE 1t • •/1 • CITY OF TUKWILA APPROVED JUL 'Y 1991 f t • • IT, c1/4. • CITY OF TUKWILA APPROVED JUL = 1991 d� �.n BUILD NG DIVISION RECEIVED (ITy TI IKWILA JUN 29 1991 PERMIT CENTER N - 1.1...L1.1111111.4 r rr CITY OF TUKWILA APPROVED . JUL A ; 1991 B ILDING DIVISION RECEIVE) CITY OF TUKWILP JUN 2 8 1991 PERMIT CENTER • 4 4 ; 1 nf Y ?' { • ti 1 \ • MINEVISO 4 . `O G cn JUN 281991 PERNIITCENTER CITY OF TUKWILA APPROVED JUL 1991 BUIL.I G DIVISION • RECEIVED MY OF Tl ll <WILA ,root Lags wi 11 he excavated Into undisturbed e•(rth unlesa soils investigation T,on is provided per Section 2907 (a) and Table 20 -A, 1955Uniform Building Code. Foundation width and thickness requirements shall be in accordance with Table 29 -A, 1988 Uniform Building Code, shown below. Each floor containing the load of a stud wall is considered a story. Stepped footings and walls shall be tied one level to another with continuous rebar. (lobar shall be accurately placed, supported, secured against displacement, and cleaned prior to calling for inspection. (lobaT:at the time concrete is placed shall be free from mud, oil, frost, or any other materials that adversely affect bonding. Con crete will not he placed on frozen ground and shall be protected during freezing or near freezing weather per Section 260S (f), 1988, Uniform Building Code. Stub steel is required when placing footings and walls separately. It shall be placed 12" from corners then 36" 0.c. and will protrude 16" above' tooting. All wood forms which have been used in placing concrete shall be removed before a building is occupied. Pressure treated or foundation grade cleats will be the only acceptable ttiood member left between footing and foundation walla Unless an approval design is provided, foundations for masonry and concrete fireplaces shall contain reinforcing steel, be not less than 12" thick, and extend not less than 6" outside the fireplace wall. All foundation walls and footings will contain rebar as shown below. Footings will always, have a minimum of two 1t4 rebar continuous. TABLE NO, 29•A— FOUNDATIONS FOR STUD BEARING WALLS — MINIMUM REQUIREMENTS 'r Id' id} cautions (g� w4e4o04.-.) 10{, . g} it DEPTH OF FOUH04TIOH WIDTH THICKNESS DCLO W HUMBER THICKNESS OF OF OF NATURAL OF FOUNDATION WALL FOOTING TOOTING SURFACE STORIES (Inches) (Inches) (IncMfl OT CROUHO UNIT AN`RAIDMESH CONCRETE MASONRY MOW 1 12 CO 12 2 CO co 15 18 B 18 24 ,root Lags wi 11 he excavated Into undisturbed e•(rth unlesa soils investigation T,on is provided per Section 2907 (a) and Table 20 -A, 1955Uniform Building Code. Foundation width and thickness requirements shall be in accordance with Table 29 -A, 1988 Uniform Building Code, shown below. Each floor containing the load of a stud wall is considered a story. Stepped footings and walls shall be tied one level to another with continuous rebar. (lobar shall be accurately placed, supported, secured against displacement, and cleaned prior to calling for inspection. (lobaT:at the time concrete is placed shall be free from mud, oil, frost, or any other materials that adversely affect bonding. Con crete will not he placed on frozen ground and shall be protected during freezing or near freezing weather per Section 260S (f), 1988, Uniform Building Code. Stub steel is required when placing footings and walls separately. It shall be placed 12" from corners then 36" 0.c. and will protrude 16" above' tooting. All wood forms which have been used in placing concrete shall be removed before a building is occupied. Pressure treated or foundation grade cleats will be the only acceptable ttiood member left between footing and foundation walla Unless an approval design is provided, foundations for masonry and concrete fireplaces shall contain reinforcing steel, be not less than 12" thick, and extend not less than 6" outside the fireplace wall. All foundation walls and footings will contain rebar as shown below. Footings will always, have a minimum of two 1t4 rebar continuous. TABLE NO, 29•A— FOUNDATIONS FOR STUD BEARING WALLS — MINIMUM REQUIREMENTS 'r Id' id} cautions (g� w4e4o04.-.) 10{, . g} it July 29, 1991 Mr. Dale Sweet 7503 South Taft Seattle, WA 98178 Dear Mr. Sweet: Sincer CITY OF TUKWILA 6200 SOUT!ICENTER BOULEVARD, TUKWILA, WASHINGTON 98188 RE: Building Permit #91 -266 Swanson Residence 4616 South 124th Street, Tukwila, WA As you and our staff have discussed, the new addition proposed at the . above address does not meet the required 30' front setback. However, the Tukwila Zoning Code gives the Director of Community Development the authority to reduce this setback to be consistent with other properties in your neighborhood. You were given the option of revising your plans or submitting a request for a waiver to the setback. You elected to request a waiver, and I have completed my review of your request. 4 Based on the photos and map which you submitted (7/17/91), it appears that the typical setback of other homes along your streets ranges from approximately 13 feet to 24 feet. This is similar to the 22 -foot setback of your existing house. In addition, your application shows that the proposed addition will not extend any farther into this existing 22 -foot setback. Based on this information, staff has concluded that your proposal is consistent with existing adjacent conditions. Therefore, your request for a setback of 22 feet is approved. Now that the setback issue is resolved, we can continue your permit application review. Please call our Building Division's Permit Center at 431 -3672 for information on your permit. L. Rick Beeler Director, Dept. of. Community Development cc: Building Official Permit Coordinator dirP W ac v 5 - P!lONE # (206) 433.1800 Gary L, VanDusen, Mayor activity log CITY OF TUKWIL APPROVED • JU . 1991 AsAo 47I • BUILDI G DIVISfC • • (.) ( 1.,01)( A (1, Date SEPARATE PERMIT AND EmcnzICAL - APPROVAL REQUIRED $7 4745y.oitkizaVni.717.0 . _ _WbVitA 71 osoro0, \\Iota b '41 . ..I • • 'L•. • \ IJ I "I ••./. • • a_ 1 1 ‘1•: .; 1 4 ■Ii FILE 0 eld Zec .,t. I understand that thtrPran Ch k approvals aree 3ublect to errors and omission, and approval of plans does not authorize the vi lat ion of any adopted code"oro Receipt of contractor's copy of approved plans acknowledged. By Permit No Ti 1j 1/1 14/tete _ 8 RECEIVE CITY OF TIJKV ILA ni JUN 2 8 1391 / - PERMIT CENTER Ci as0.ca OF PHONE l 77 S55 AREA CODE NIJ R EXTENSION MESSAGE ••• f CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUKWILA, WASHINGTON 98188 Plan Check #91 -266: Swanson, David 4616 S 124 St PHONE II (206) 433.1800 THE FOLLOWING COMMENTS APPLY TO AND BECOME PART OF THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER 1. No changes will be made to the plans unless approved by the Tukwila Building Division. 2. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (872 - 6363). 3. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 4. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 5. All construction to be done in conformance with approved plans and requirements of, the Uniform Building Code (1988. Edition), Uniform Mechanical Code (1988 Edition), and Washignton State Energy Code (1989 Edition) and compliance will be subject to field inspection. 6. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for , or an approval of, any violation of any the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. Gary L. VanDasen, Mayor "X" REQUIRED INSPECTIONS PHONE DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 R 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431-3670 X 7 Framing 431 -3670 X 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 X 10 Wall Board Fastening 431 -3670 11 12 13 14 FIRE FINAL lnsp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 x 17 BUILDING FINAL 431 -3670 (INSPECTOR COMMENT SECTION ON REVERSE) SITE ADDRESS: 4616 S 124 CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDIG PERMIT INSPECTION RECORD (Post with Building Permit in conspicuous place) SUITE NO.: BUILDING PERMIT NO. DATE ISSUED: PROJECT: Swanson, David CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar Is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - if structural slab or if undersiab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries -- 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. 00„4,9 PAN REVIEW COMM COMMEhciS Plan Check No.: l' Z-ww Project: 0 No changes will be made to the plans unless approved by the ,A iiteeb -awl-04e Tukwila Building Division. REQUIRED INSPECTIONS 0 0 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277- 7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high.strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 11 Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), GuMpt1A►44 Wril�� eot°5,w.C•Z"' 18. All food preparation a i s ablish have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the job site, 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. 1. Footings 2. Foundation Slab /Slab Insulation ip 3. 4. Shear Wail Nailing r 1 5. Roof Sheathing Nailing 6. Masonry Chimney 4 7. Framing pall 8. insulation IN IAN 9. Suspended Ceiling 10. Wall Board Fastening 11. 12. 13. 14. Fire Final 15. II Planning Final 16. Public Works Final 17. Building Final PAN REVIEW COMM COMMEhciS Plan Check No.: l' Z-ww Project: 0 No changes will be made to the plans unless approved by the ,A iiteeb -awl-04e Tukwila Building Division. REQUIRED INSPECTIONS 0 0 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277- 7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high.strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 11 Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), GuMpt1A►44 Wril�� eot°5,w.C•Z"' 18. All food preparation a i s ablish have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the job site, 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. p pr pioneer National Title Insurance Company WASHINGTON TITLE DIVISION between REAL ESTATE CONTRACT THIS CONTRACT, made and entered Into this 19th day of June, 1972 WILLIAM J. ZIN1ERLIN, as his separate estate hereinafter called the "seller," and DAVID C. SWANSON and MERLE J. SWANSON, his wife hereinafter called the "purchaser," WITNESSETH: That the seller agrees to sell to the purchaser and the purchaser agrees to purchase from the seller the following described real estate, with the appurtenances, in King County, State of Washington: Lots 24, 25 and 26, Block 5, Allentown Addition, according to plat recorded in Volume 12 of Plats, page 100, is King County, Washington. No Reserve Account Required. • As referred to in this contract, "date at closing" shall be... Ju;1Y 10 1972 The terms and conditions of this contract are as follows: The purchase price is TWELVE • THOUSAND FIVE HUNDRED AND NO /100 a$12 p 500000.....) Dollars, of which FIVE HUNDRED AND NO /100 - —) Dollars haVe been paid, th): receipt whereof Is hereby acknowledged, and the balance,of said purchase price shall be paid as 'follows: ONE HUNDRED AND NO /100 ($ 1A0.00 ) Dollars, or more at purchaser's option, on or before the 10th day of July ' ► and ONE HUNDRED AND NO /100 ($ 100. 00 ) Dollars, or more at purchaser's option, on or before the 10th day of each succeeding calendar month until the balance of said purchase pei a shall have been fully paid. 'The purchaser further agrees to pay interest on the diminishing balance of said purchase price at the rale of — 7 - per cent per annum from the let day of which interest shall be deducted from each ltistallment payment and the balance of ea . - ,o • •• d In reduction of principal. All payments to be made hereunder shall be made at SEATTLE FIRST NATICh lik' ° _ . S it'f ter Branch or at such other place as the seller :nay direct in writing. � ; s7 1.8451 ` t ' yi14 July . 19 ?2, A•I... RECEIVED • CITY OFTIJKWI,I.A JUN 2 8 1991 PERMIT CENTER (1) The purchaser assumes and agrees to pay before delinquency all taxes and assessments• that may as between grantor and grantee hereafter become a lien on said real estate; and if by the terms of this contract the purchaser has assumed payment of any mortgage, contract or other encumbrance, or has assumed payment of or agreed to purchase subject to, any taxes or assessments now a Ilea on said real estate, the purchaser agrees to pay the same before delinquency. (2) The purchaser agrees, until the purchase price is fully paid, to keep the buildings now and hereafter placed on said real estate ' insured to the actual cash value thereof against loss or damage by both fire and windstorm in a company acceptable to the seller and for the seller's benefit, as his interest may appear, and to pay all premiums therefor and to deliver all policies and renewals thereof to the seller. (3) The purchaser agrees that full inspection of said real estate has been made and that neither the seller nor his asslgna ah611 beheld •