Loading...
HomeMy WebLinkAboutPermit 6708 - Segale Business Park - Reroof6708 91-319 segale 18290 andover park west reroof Permit 6708 - Segale 'PE. 'SI - - Reroof lB Di. year) 1988 . SETBACKS: N- S - E- W- FIRE PROTECTION: r--, pg Nth uSprinklers 0 Detectors UTILITY PERMITS REQUIRED? PR (---1 v r l_J ' es i__, No (t P l u ro b t lic gt Norks) ZONING: BAR/LAND USE CONDITIONS? Dyes 0 No CONDITIONS (other than those noted on or attached to permit/plans) SEE ATTACHED"REROOF CONDITIONS" REGARDING VERIFICATION OF CLASS1F1CAllUN. I) P 10 Sedate Business Park PHONE 575-3200 ADDRESS 18010 Southcenter Parkway ZIP 98188 CONTRACTOR Seale Business Park PHONE 575-3200 ADDRESS 18010 Southcenter Parkway ZIP 98188 WA. ST. CONTRACTOR'S LICENSE # SEGALBP151M5 EXP. DATE 07_09 _92 ARCHITECT PHONE ADDRESS ZIP CITY OF TUKWILA Dept. of Community Development-Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431-3670 BUILDING PERMIT NO. DATE ISSUED: SITE ADDRESS PROJECT NAME/TENANT S e USE APPROVED FOR ISSUANCE BY: Liiog \ 1 \ 64its : ■■••=1■111101MY 18290 Andover Park W ale TYPE OF U New Building U Addition U Tenant Improvement (commercial) U Demolition (building) U Grading/Fill WORK: 0 Rack Storage (Z) Reroof 0 Remodel (residential) 0 Other: DESCRIBE WORK TO BE DONE: Repair existing roof. CODE COMPLIANCE OTAL SQUARE FEET OCC, LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCC LOAD SIGNATURE: • CERTIFICATE OF DATE ISSUED: OCCUPANCY NO. BUILDI4G PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) FEES DESCRIPTION BUILDING PERMIT FEE PLAN CHECK FEE BUILDING SURCHARGE TOTAL- AMOUNT 350.00 RCPT.': PLAN CHECK NO.: 91 SUITE # BUILDING OFFICIAL VALUE OF CONSTRUCTION - $ ASSESSOR ACCOUNT # DATE: 7,, 39,900 3523049018 I hereby certify that I have read anCi this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit . does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. DATE: PRINT NAME: ..5 COMPANY: Ic i „ . • This permit shall become null and void if the work is n�t commenced "itii#7:;409 frOritlf*data::: of issuance, or/f the work is suspended or abandoned for a period of 180 days from the last inspection I '?I PERMIT NO. CONTACTED ate ,. DATE READY DATE NOTIFIED 1 `31 91 BY: (init.) - In PERMIT EXPIRES 2nd NOTIFICATION 3RD NOTIFICATION BY: (i1) BY: (init.) AMOUNT OWING t BUILDING CERMIT APPLICATION TRACKING PLAN CHECK NUMBER ql -6(9 INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) FL • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". in "I O FIRE O OTHER SQUARE FEET P `.TME O BUILDING - initial review O PUBLIC WORKS 4 0 / INIT: O BUILDING - final review OCC. LOAD REVIEW COMPLETED PROJECT NAME SITE ADDRESS SUITE NO. r Qar1 •� A II SQUARE OCC. FEET LOAD RO (ROUTED) SQUARE FEET OCC. LOAD DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. CONSULTANT: TYPE OF CONSTRUCTION: SQUARE OCC. SQUARE FEET LOAD FEET E Date Sent FIRE DEPT. LETTER DATED: INIT: O PLANNING ` ZONING: , REFERENCE FILE NOS.. INIT: MINIMUM SETBACKS: N- PUBLIC WORKS LETTER DATED: S- UTILITY PERMITS REQUIRED? 7 Yes OCC. LOAD Date Approved TOTAL SQUARE FEET FIRE PROTECTION: ( ) Sprinklers (l Detectors (1 N/A INSPECTOR: BAR/LAND USE CONDITIONS? Yes UBC EDITION (yearj: TOTAL OCC. LOAD I HEREBY; CERTIFY;THAT;I HAVE READ AND. EXAMINED THIS APPLICATION AND' KNOW:THE;SAME TO BE TRUE AND :CORRECT, AND I. AM AUTHORIZED TO APPLY FOR THIS :PERMIT BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE 2�l c� 2 /f ,1--- DATE 7 - Z 9 - 5 / `i - ?O i "7 - 3o -4 i ) PRINT NAME Steven R. Nelson ENERGY SURCHARGE PHONE 575 -3200 PHONE 575 -3200 ADDRESS Pp Box 88050 Z1P98188 CONTRACTORSegale Business Park j CITY /ZIP Tukwila 98138 CONTACT PERSON Steve Nelson �j/ PHONE ADDRESS ZIP PHONE 575 -3200 DESCRIPTION AMOUNT RCPT # DATE BUILDING PERMIT FEE 5().00 4 4:60 ?7VQ D 6 `i - ?O i "7 - 3o -4 i ) PLAN CHECK FEE BUILDING SURCHARGE ENERGY SURCHARGE PROPERTY OWNER Segale Business Park PHONE 575 -3200 OTHER: Z1P98188 CONTRACTORSegale Business Park j _ TOTAL - 3L) ST) EXP. DATE 7_09 -92 �j/ SITE ADDRESS SUITE # 18290 Andover Parkwest VALUE OF CONSTRUCTION - $ $39,900.00 PROJECT NAME/TENANT SBP 741 roof ASSESSOR ACCOUNT # 3523049018 TYPE OF U New Building U Addition U Tenant Improvement (commercial) U Demolition (building) WORK: ❑ Rack Storage Sa Reroof ❑ Remodel (residential) ❑ Other DESCRIBE WORK TO BE DONE: Repair existing roofing BUILDING USE (office, warehouse, etc.) NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? > 6j No U Yes IF YES, EXPLAIN: SQUARE FOOTAGE - Building: 7 25 4 6 Tenant Space: Area of Construction: 72546 WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? CD No ❑ Yes IF YES, EXPLAIN: PROPERTY OWNER Segale Business Park PHONE 575 -3200 ADDRESS Z1P98188 CONTRACTORSegale Business Park PHONE 575 - 3200 ADDRESS 18010 Southcenter Parkway IZIP 98188 WA. ST. CONTRACTOR'S LICENSE # SEGALBP151M5 EXP. DATE 7_09 -92 ARCHITECT PHONE ADDRESS ZIP CITY OF TUKWILA Department of Community Development - Building Division 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 433 -1849 PLAN CHECK NUMBER DATE APPLICATION ACCEPTED �1 - 30_crI BUILDII' a PERMIT APPLICATION FEES (for staff use only) APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 433 -1851 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 433 -1849. DATE APPLICATION EXPIRES 61.0100 COMMERCIAL NEW • Two sets (2) of the foRowln Specficadons I Structural .+•••••:1112. 1"Dns license stamped by a WashlnQton Slate license lnoer I TopographII survey Energy calculations stamped by a Washington State Icon an9lneer or architect • Architectural drawings 'Structural drawings • Mechanical • drawings Elevations Completed utility permit appllcatto drawings (pp 0for entire } (6) sets civil drawings ........,...,.,.... . . . :M .,,,........,,........,...,...."......,...‘... -.... ... . . . . pic./00!■:...';iii;.1..... ... ...:,..:...,::'...::.,....:',,,.■,...1...........:...::.".'''.":".::::"....'. . .. — .... ............... •“....., Compl ' ." iii Oi*I?"?.;i:::..„.„,:?:„ i„:%,.:..... o‘......,.,.., i : :ll;::f:: i 0;iii i* t1I°IP !!!. : :::' . ' , ' .... : ;;..:::: . ...... , . 1 ........ .•7 fi:::::::::::!::::::::,:i ...,.., 64- 611a .. tin''..111!..... :;:1...-1..:?i..:::-. la yout , a ;11 TenallillPane:fiber•Ritlq 7 :*.pioen.s . ‘9,. ,:,..::: ,. i::::„:„.:,.... • --.., aillte,. ... ..... ........_ ; •,NQT . E ; , ./i000 9 ' evaenSion 0 q #,.!..if..w4?),fyprnf?...::::;5:::::::::::::::::::::::::ii:':.::::.,::::::i:::::::::::„:*:',........... . . Structural calculations StaMPed by a Washington State license . :. :engineer (r.ackistorage.8. ,...„:„.:„......:::...,&....;..,........:.::::::;.,.....„ . ••.:.... ''' ••:',.:::]•:::••,:••••••• RESIDENTIAL .. .. . „ . ..... . .. . .. . . .. „ .. , . . .. . . . . . . . ... . . . . .. ;,„ . . . . NEW SINGLEFAMILY DWELLINGS/ADDITIONS corripteteci beildirig . permit application (one for each structure) E Assessor Account Number .. • . Two sets (2) of working drawings, which Include ." . • • • • • . • ,...• -• • Root • . „ . . . Building elevations (all 1ews) Building crass section Stiuctural framing plans . . Washington State Energy Code data ..*. • .. , : .. • Completed utility Permit application ••••••• • • • NX (6) sets of site plans showing utilities • • • • • •:, NOTE: Building site plan and utility site plan may be Combined,: See utility permit application and checklist fo specific subtnittal.TluiretTif?nts; . . . . Adcitional topographical and soils information may be required,! unique site condidons. . . . . aMITTAL CHECK1ST POMMEriPiA4':I.EtiART. . . . , . .......,:. . Completed building permit application (one for each structure or Assessor Account Nu" , • Site plan • •• 7 difotteOantioa • Existing and proposed pai • .j.i.:;TanOnt !?,..Ot!"qiia . . r - 1. ! • • • r aPPlibatiOrterld• Completed builng permit application (ono for each strUctu Narrative de,0*tblog: • existing ••••.nOti:enatodo being removed, an ..„ • .• „niganat • • . . ... . .... Completed building permit application (one for each structure) Two (2) sets of working drawings, which Include • Site plan • Foundation plan . • .. . • Building cross section • • • -.•••••,••••••••••••••••••••••••.••••••••,•,•• •,":„ NOTE If to bsIdOtta provide utility permit application 000.1;4,0S Oust be submitted. "" • "" • •.• • • • . . . . . . .•.- .. R EROO FS ....... .......... ................. ....„ „. • . .. . • ... Completed building permit appliCatiok(onkftir each structure) Assessor Acc ount Number •••• , .. • 'Narrative des Cribing:erriating roof, material being removed, and Material being Installed . : . • NOTE A certification fatter Is required prior to final Inspection and sign- off of thePerinik: . : Project: "T ype of Inspectior /.... r re__ Address: a 4p Date Called: 2'- ~' r 3 Special Instructions :. Date Wanted: 2- 2s --� .3 a p.m., Requester: Phone No.: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 A Approved per applicable codes. COMMENTS: C, INSPECTION RECORD Retain a copy with permit 1 -3670 \' 0 ; Corrections required prior to approval. 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 ...5=7"— -,(44 c- 7- Li/ ype o nspection: ot)F •", N — Address: 9'Z, f P, tti1. Date Called: 2 —3— 9 2- Specs l Instructions: Date Wanted: am. p.m. Requester: Phone No.: .37.5 L INSPECTION RECORD C Retain a copy with permit INS 'E • NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Approved per applicable codes. 7 PERMIT NO. l Corrections required prior to approval. ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (206) 431 -3670 COMMENTS: /. .D(), I-1C) -fir �1cr �rct� n,S / - 3rtil 9tS Cu C 'vn i N 4,J a+C � ∎r t+'L -t34- r fnrJ',f) lS -tlL.. 7 - 1 4 c�C A .J'() (S. v � —�.��� v T \ i E SDI A AL-!L B •.1"{ `t f C - YZ.- F p C-1 G C + z ,.Y ra Rc7 - 0r- A vy, ► 1.N-04.._ r;r.A� ee '_" vj 1 t c,(tk rel A• C r3E I a otr f re.E er2.6 45t_ mS nspector: receipt No.: "Date: PROJECT: : f # 1 , _ PERMIT NO. ' DATE CALLED: o • '� g I-- 9 SITE ADDRESS: 1.. I i A so* • r" ai, TYPE OF INSPECTION: • ' L > DATE WANTED: 6 _ a ^ 9 a. SPECIAL INSTRUCTIONS: REQUESTER: .� (,(Q ill ? lPX �-�� 3aO PHONE NO.: INSPECTION RESULTS /COMMENTS: 40A- 1‘434 re INSPECTOR: d; DATE: 4 ! -- I CITY OF 'TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 a.' . :.:..`.. �w';�:ti•�::�Rxii�:: � s' i�f i:�F�`Y..� i:.u:.rdr. ti:i*A1.A..Ag INSPECTIO RECORD 6300 Southoenter Boulevard — #100 Tukwila Washington 98188 17506 BOTHELL WAY NORTHEAST BOTHELL, WASHINGTON 98011 • (208) 367 -4011 • 487-2329 'February.3,1992 City of Tukwila Department of Community Development Building Division 6200 Southcenter Boulevard, Tukwila, WA 98188 To Whom it may Concern: RE: Building # 741 of Segale.Business Park, 18290 Andover Pk. W., Tukwila', Washington We,,as Commercial Industrial Roofing, Inc., installed a roof membrane assembly, which did not include insulation, consisting of Malarkey Specification # NS 3 >.Heavy Duty;: data sheet enclosed,; whcih meets,. for: "exceeds the requirements for: Class A or Class B roofs. This roof was: installed at above ,Building;. #.;741, under:. City. of .Tukwila-building' permit number 4 .57.7 47 t>8 4 • Malarkey BUILT-UP ROOFING SPECIFICATIONS ALL ZONES SLOPE -0" to 3" FIBRATED EMULSION U.L. CLASS "B" -- Up to 1 /2" slope CLASS "A" — Up to 1 /2" slope with ISOCYANARATE SBS PREMIUM 1 BASE SHEET NO. 501 SBS PREMIUM 1 BASE SHEET NO. 501 Per 100 Square Feet 1 ply 5 lbs. 3 plies 90 lbs. 50 lbs. 15 -25 lbs. 3 gals. 24 lbs. 2 gals. 18 lbs. 2 gals. 18 lbs. Materials Rosin sheet recommended Glass Premium 1 Base Sheet No. 501 Asphalt between piles Asphalt surface or Emulsion and /or Aluminum or Malarkey Rhino -Hide Ti -Cote Follow general requirements. APPLICATION: Over wood boards only, lay one ply of rosin sheathing, lap each sheet 2" and nail to hold in place. NS3 HEAVY DUTY ASPHALT, EMULSION, ALUMINUM CERAMIC GRANULES Apply Malarkey Premium 1 SBS Base Sheet so flow of water is over laps. Lap each sheet 2" on sides and 6" on ends. Nail each sheet as required, turn up 2" above cants at verticals. At a uniform rate apply hot asphalt to base sheet per diagram. Sheets shall be applied so flow of water is over laps. End laps shall be at least 4" and adjacent end laps 12" apart or more. Broom each ply gently and turn up 2" above the top of the cant and shall be solid mopped to vertical wall. Coat entire surface with a uniform application of specified hot asphalt, emulsion and /or aluminum coating. Malarkey recommends the use of its SBS Mineral Cap Sheet No. 601 or SBS 3 -Way Type Mineral No. 917 as a base flashing material. Malarkey recommends the use of its SBS Walk Board No. 916 for all traffic areas. "X" REQUIRED INSPECTIONS PHONE APPROVED INITIALS CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 7 Framing 431 -3670 8 Insulation 431 -3670 9 Suspended Ceiling 431. -3670 10 Wall Board Fastening 431 -3670 X 11 Re 2.e. v o9U1 )4 ' Noo 12 13 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 x 17 BUILDING FINAL 431 -3670 CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: 10290 Andover Park W BU1LD1G PERMIT INSPECTN RECORD (Post with Building Permit in conspicuous place) SUITE NO.: BUILDING PERMIT NO. Co 705 DATE ISSUED: 7 — _ PROJECT: Segale CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE INSPECTOR COMMENT SECTION ON REVERSE) INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if underslab Insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. o9„4/oo July 29, 1991 Segale Business Park P.O. Box 88050 Tukwila, WA 98138 Attn: Mr. Steve Miller Dear Steve: e R A T T I SWENSON PER B I X CLARK Re: Roof Structural Capacity - Segale Bulding 741 Segale Business Park Tukwila, Washington As you requested by phone on 25 July 1991, we have reviewed our original structural design for the referenced building to determine it's ability to sustain a proposed additional roofing membrane. We have . based our analysis on the existing roofing, weighing 1.41 pounds per square foot (psf), and the proposed additional roofing at 2.1 psf. You telephoned these weights to our office. Our calculations show that the existing roofs structural system can sustain the additional roof's weight without overstressing the members. The controlling element is the 47.16 roof purlin at 8' -0" o.c., which can accept only an additional dead load weight of 1.8 psf. If we can be of further assistance in this matter, please advise us. Sincerely, RATTI SWENSON PERBIX & CLARK i2a10 I Dean B. Ratti, P.E. DBR/ta RECEIVED CITY OF TUKWILA JUL 3 0 lyol PERMIT CENTER A Prufessionul Service Corporation 1411 4th Avenue Building, Suite 500 Seattle, Washington 911101 Phone 20¢,624.8687, Fux 206,624,8268 July 29, 1991 Duane Griffin CITY OF TUKWILA 6300 Southcenter Boulevard Tukwila, Washington 98188 Re: Segale Business Park Building 741 18290 Andover Park Weest Dear Duane: S,EG.Al-E" EUSINESS P.404K If you need any additional information • The existing roof membrane is a class "B" built -up roof with an aluminum reflective coating. The roof will be repaired with Malarky specification #NS3 Heavy Duty system with ceramic granules. Enclosed is a letter from the engineering firm of Ratti, Swenson, Perbix & Clark, P. S regarding the additional dead load and the existing roof structure. Sincerely, SEGALE BUSINESS PARK Steve Nelson Enc. P.O. BOX 88050 I TELEPHONE: (206) 575.3200 • please call me at 575- 5200. RECEIVEp on OFTYPABLa 'Jul. 'gyp i PERMI'tCENTER FAX: (206) 575.3207 N TUKWILA, WASHINGTON 98138