HomeMy WebLinkAboutPermit 6719 - Dr Eugene Hunt - Build Out6719 91-267 dr eugene hunt 13030 military road south #208 Permit 6719 - Dr Eugene Hunt TYPE OF CONS1`.: V —N UBC EDITION (year) 1988 SETBACKS: N — S - E— W— FIRE PROTECTION: Sprinklers 0 Detectors x0 N/A UTILITY PERMITS REQUIRED? 0Yes ® No ( Pyblic Norks) ZONING: BAR /LAND USE CONDITIONS? 0 Yes © No CONDITIONS (other than those noted on or attached to permit/plans) ARCHITECT Kovach /Ovitt Partnership PHONE 485 -3838 ADDRESS 7415 222nd Street S.E., Woodinville, WA ZIP 98072 "•P • R Hi -hline Communit Hospital PH•N 431 -5343 ADDRESS 16251 Sylvester Road S.W., Seattle, WA ZI P 98166 CONTRACTOR Lumpkin Construction PHONE 329 -1129 ADDRESS 1627 Eastlake Avenue East, Seattle, WA ZIP 98102 WA. ST. CONTRACTOR'S LICENSE # LUMPKI242BE EXP DATE 12 - 23 - 91 ARCHITECT Kovach /Ovitt Partnership PHONE 485 -3838 ADDRESS 7415 222nd Street S.E., Woodinville, WA ZIP 98072 BUILDINC, PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) CITY OF TUKWILA Dept. of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDING PERMIT NO. DATE ISSUED: 1 1 s-q-91 :PROJECT. -INFORMATION VALUE OF CONSTRUCTION - $ 70,000.00 PROJECT NAME/TENANT Dr. . Eugene Hunt ASSESSOR ACCOUNT It 162304 - 9171 - TYPE OF U New Building Li Addition (.) Tenant Improvement (commercial) Li Demolition (building) U Grading/Fill WORK: 0 Rack Storage O Reroof 0 Remodel (residential) O Other: DESCRIBE WORK TO BE DONE: Build -out of existing shell:to medical suite. SITE ADDRESS APPROVED FOR ISSUANCE BY: SIGNATUR CERTIFICATE OF OCCUPANCY NO, 13030 Military Rd S J 12.P 0 DESCRIPTION :: ;' AMOUNT RCPT # :: DATE '.;<:.:< `1$111 B.UILDING;PERMITFEE 505.00 PLAN CHECK FEE 328 00 0031 7 011 BUILDING:.SURCHAR E 4 50 I I ( OTHER <<'>>':: TOTAL PLAN CHECK NO.: SUITE it 208 CODE COMPLIANCE USE .4Of .f ice: /B - FLOOR:i SQUARE OCC. W FEET LOAD 1,610 18 SQUARE FEET OCC. SQUARE OCC. LOAD FEET LOAD SQUARE OCC, FEET LOAD SQUARE FEET / OCC. LOAD TOTAL SQUARE FEET 1,610 1,610 TOTAL OCC, LOAD 18 18 AVANILT WANT T• di) PRINT NA BUILDING OFFICIAL I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of lav and ordinances governs ± thi work will be complied with, whether specified herein or not. The granting of this permit does not presume to g • a,t ority o violate or cancel the provisions of any other state or local laws regulating construction or the an e o work. I am authorized to sign for and obtain this building permit. DATE: 1 A,/lr I c l I COMPANY: K00 dvtTt ' tr2r,JErcSN1.P is pe � „shall become null and void if the work /s not commenced wit m 180 days from the :date o. issuance, or if the work. i s suspended ora bandoned :fora period of ;180 days from the last inspection DATE ISSUED: DATE: 7 3 Y / 91 -267 PERMIT NO. CONTACTED Left- hr e `�- \ � D C , DATE READY DATE NOTIFIED 1 ^ or — � BY: (init.) PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING O I 5 3RD NOTIFICATION BY: init. BUILDING )ERMIT APPLICATION TRACKING PROJECT NAME PLAN CHECK NUMBER 1 - a(p -- ) INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) .6.1.001:14; SQUARE OCC. FEET LOAD SQUARE FEET OCC. LOAD !T O SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. D EPARTM ENT t! BUILDING - , initial review a SITE ADDRESS SUITE NO. 7 CONSULTANT: Date Sent O PLANNING AbeAre /67. O PUBLIC WORKS O OTHER N,H l!Q BUILDING - 7 z2 - cfl final review REVIEW COMPLETED INIT: INIT: INIT: FIRE PROTECTION: Sprinklers Detectors N/A FIRE DEPT. LETTER DATED: 7 — / - -- qJ INSPECTOR: 5) 3 REFERENCE FILE NOS.: MINIMUM SETBACKS: N- S- UTILITY PERMITS REQUIRED? Yes PUBLIC WORKS LETTER DATED: TYPE OF CONSTRUCTION: v\1 Date Approved - nog UBC EDITION (year): TOTAL OCC LOAD IBAR/LAND USE CONDITIONS? ( )Yes �No CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER SITE ADDRESS t Ma-triaz a& PROJECT NAME/TENANT DESCRIBE WORK TO BE DONE: CflrMatERc. th J Ntf D1C■L c•5heAr4V ';) tr BUILDING USE (office, warehouse, etc.) MEsnCfkL 01Ft NATURE OF BUSINESS: 1 etc i WILL THERE BE A CHANGE IN USE? fi DATE APPLICATION ACCEPTED SIGNATUR PRINT ADDR (Di SUITE # � za 74)6 222,1* BUILDIN PERMIT APPLICATION APPLICATION.,,iVIUS:T, BE. FILLED O..U:T COMPLETELY _ DESCRIPTION ' ° <.<i' <; BUILDING .PERMIT FEE PLAN CHECK FEE UILDING SURCHARGE:. . THER: 4wJ tU V t"('I"_ 4-VA 1 - ,RCPT * Z TOTAL:: VALUE OF CONSTRUCTION - 10 0 ASSESSOR ACCOUNT # . EOC.rENi F t � ._ 2309l7i —O ilding TYPE OF U New Bu Addition Tenant Improvement (commercial) Demolition (building) WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) 0 Other* f3utLD-our ai= E2CtSrt 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: a ) 17 ) 9 Tenant Space: ) r fo) 0 Area of Construction: t r 6 ) 0 W BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? lJ No 0 Yes IF YES, EXPLAIN: ADDRESS CONTRACTOR ADDRESS WA. ST. CONTRACTOR'S LICENSE # ARCHITECT ADDRESS 741' .222 sr. s• BUILDING OWNER OR AUTHORIZED AGENT PHONE IZIP EXP. DATE AMINE!) ; T t 8:« ►1 P:LIC:A'Tl D:T O:AP PLY DATE PHONE $� 4 $ CITY/ZIP J d D t *f "J\LLE CONTACT PERSON w (fiat ittE MAthb2_,�Q EL 1 PHONE .1 fst�c� -� . APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431-3670. DATE APPLICATION EXPIRES 03/16791 COMMERCIAL :NEW. [J Completed budding permit application (on . . • .. Assessor Account ..:.•.: followinc . . EaSpecificatiOna• si • structural calculations starnpedbylaWaShitigttia State (cep • • •••• ..• Soils report stamped by a WashingtoaStatalicenied engineer 1 Ener calculations stamped by Washington:State liCeriSed:• • .... engineer or architect , Wt)ricing drawings, stamped by ..a Washington State licensed architect; which include.. • .. . . . • Site plan Architectural drawings Structural drawings Mechanical drawings • Elevations Landscape plan • Completed utility permit application (one for entire pro SIX.(6) . df . . civil drawings NOTE See utilisy permit application and checklist for specific utlh4' . . subittitttci:r:equirelnpnts... . . • . . • Com pleted building permit application ..„.. '..Assessor Account Number Two (2) sots of plans which include E Building floor plan showing Exit doors ..... . . • . . . .E.Tenant space floor piroski.*Ing exits ..... . .....,...:. . NOTE: Include dimensions Of .rackk(heit4ht,: ':aiSittit and �xft ways on plan Structural calculations StaMPed..by• • . . ... . . . . • . . RESIDENTIAL — SUBMITTAL CHECKLIST ....• ...„ Completed building permit . • f or .. . •• Two sets (2) of working .1 Site • Foundation plan lackmfe4tccess to building:: shovrinv: • Floor plan . . . •:„ We/rand length • Roof plan . • : : • • :: • Building elevations (all views) • • : • • : .r : • Building cross-section Structural framing plans : ... . . . . ••. Washington State Energy Code data Completed utility permit application : •• ..• . 1 .• riSix (6) sets of site plans showing utilities NOTE: Building site plan and utility site plan may be combined.. See utility permit application and checklist for specific submittal requirernents: Ad:Nonal topographical and soils information may be required if unique site conditions. M • , for ea tenant) ietw:A000.0 t Two (2 sets of construction plans1 Which incltr . Location of tenant space * Existing and proposed parking • Landscape plan (U applicable I a change of use) Overall building plan • Tenant location • Use of adjacent (common wall) tenant • Overall dimensions of building or SJare footage E • •• Floor 044M • Tenant space plan with use of each morn labelled • Exit doo rs egress - Construction • details • • rOaa: „., sec.09±.1. cei 4% attachment • for109f and • ••' .!••••• LI Structural calculations • stamped by a Washington State licensed .................. • application and plans. ....... se utility permit . . Completed building permit ... ap plicatio n (one for each structure) Narrative descnblng existing roof material being removed and material being installed NOTE A certification ffa/• off of the permit . . . . .„ . . . ...... :••• Assees�rA000u ntNumbe Two (2)sets •••••' • . . • :.:: . .. . . •••••• .lch.. . • . cShyi..:: ...... '''Shb'tkit . ' . ...giti? .....„........9...„!!!?.......„.......,..,...........,......„:..... a . • ... ,.. , ..... . ‘.. P0 , ,i ... -....-i.:..t6 • f - . a ::dish ano.rnp;p9 ...... 51 10::........ ••••• • ••::: ........ : -. ::: .,..,.-i., : ., : : : , ..:::::::::::::::':::;:M . :::...: -.. ':::: ... '..........,..... : • : - . :nnd.:'''''.....: :: : . : ki**4 . .4i.in.iii: t . 0 : 0: : ; :.!:.' „ ?..'.::::::::::::::::: ... .: ... • :8 rOogd;k0a...,.....ii7.,7•77......:,.....„:„::::giis::::.::::.........,.......,:.,:,::::::::::::i:;::..q:R„.,:.•;„..;..,...:A::...,:..:,;:a,...1...i.......,... : r equired . ......--.....-::::::::::::::::::::.:::::'„?:::::::::•::::::::::::•:::-,:: . : ..... ..:. .... , . . . .• • . .........;.. „.......•.....:...................„:„.„..•::::.....:.........::.:..„......„.........„..... •...... ••• .. %iodation ofn! plan • Roof plan •••••• . • Building elevations (all views • Building cross-secton.' • Structural framing plans iREINM■111••• ..... . . . .. . poniofetpoiNi1000 for each stricture) .•.'irisessor:Accatint Number 1\o (2) sets of working drawings, which include • • • • • St nian . ..• NOTE:flanyutility.wor Is tobp.donn poyide permit application and plans must be submitted. REROQFS LI : • ••••• Completed building permit application (one for eaoti.itroature) El Assessor Account Number '.•;• • ....••••'. Narrative describing existing reof,:-.material beinvemoyed, and : - material being installed.:.';•••• • . : „ • NOTE :A certification letter is required prior to final Inspection and sign- off of the permit. -: PROJECT: Dr, . Z-0 PERMIT NO. (0 7 / C SITE ADDRESS: j�5D .6 � � ~ DATE CALLED: f().- ''`�! t' l . DATE WANTED: Q -- ¥ - 9 l P.M TYPE OF INSPECTI • ' : .,� SPECIAL INSTRUCTIONS: REQUESTER: l*E NO.: )/ ( le . - 753 7 _. ----.- -- .- --....E-dQ INSPECTION RESULTS /COMMENTS: � -- 7, A517ee. .7 I AI i INSPECTOR: rV� e.., rry DATE: hp- 4,r-'/ CITY OF TUKWIL-A Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTION RECORD sta 6300 Southcenter Boulevard -- #100 Tukwila Washington 98188 PROJECT: get-x.- PERMIT NO. 67 7 / 9 SITE ADDRESS: /30_3 - ..Qi_1 r S #c) DATE CALLED: /l'- Y4 " 4 TYPE OF INSPECTION: � L.�L•r� -� /� -- � . % DATE WAN TED: 9 - ) REQUESTER: '�' ' am. �- �: •, SPECIAL INSTRUCTIONS: / j PHONE NO.: '/ 9 -- 3 INSPECTION RESULTS /COMMENTS: fr INSPECTOR: �- DATE: c i - Z '7 - `l l e+ ::1�: b C' her. wutxrr. �,.,,. i.. yana., �. w« aarwx..rsnw.rw�vwrwar.>xn�:.n�� CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: ) , I� -. PERMIT NO. / . SITE ADDRESS: 1 j. A 11 i%'r � ; DATE CALLED: r q( , --- . TYPE OF . ` DATE WANTED: ti 7— A;m; INSTRUCTIONS: SPECIAL REQUESTER: pp PHONE NO.: INSPECTION RESULTS /COMMENTS: C 4)/ s� cis / 7-, r. { C � fr t ,e„--{ 7"C";<---2 INSPECTOR: ANEW - AI DATE: --/2, — CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 fi /*Aes.4n:dW.IX4q.w 1wN',... eery. suf'h tur.,..k. wnvrt isb+ te. �citbVn :�vvv.V'.91`:R +.`�Ii.YSK"i :: rCNfV1' nlffiYY .lul :t:'Ji�.:ri:l, ^vrn4'�izt i'.'.. rA�i.: aka^: v' rt aeeta�T vxMFSii +'EM1 {1N:•2`4VF1C 1i.'?I d,1 1NSPECTIOIf RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: ,.Q • • U PERMIT NO. ((51 1 "I SITE A)DRESS: l�O 1 l Y �t Rd 3 DATE CALLED: C I -C t'" q TYPE OF INSPECTION: la A i DATE WANTED: SPECIAL INSTRUCTIONS: REQUESTER: PHONE NO.: In I k. - 439. - "1"C 3"1 - 63 --A ez-dg INSPECTION RESULTS /COM S: . 0 .+o 4. ` • DATE: ( 6 - �1 INSPECTOR: v' 5!jCt::i�fCJ { :ELI."!5:'t r .t,'.74'.:,X:ilw:ta'.tQJtpiit:m nr,.xa:.t. nrrv?4t ,/,t!? f l'�:'tJ.a ^.�r:trnx- :: CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 ..'� °L�ttl,i:l?C^... L !9/ "'(.':,': i ! t• L +t�tiX'1: {1...iY'..m.!' ^{'..f n r.: W i.J'» ' INSPECTION RECORD :n:G5:i1C {t:..t:.v."1'fu�s:: t!tir11. Y.M'w•.r.24Yt;.,ztire.'. 6300 Southcenter Boulevard r- #100 Tukwila Washington 98188 September 1991 Mr. Mike glinger ;Lumpkin 6vnetruotion 1 527 Eastlake Avenue E. seattle, washington 9 —Project: Riverton Medical/Dr. Hunt 8iite Subject: Interior F,c'txmiu9 Detailing, Dear Mika t After review of the interior non- struotural. elteel stud framing at the above project, 2 concur with your method or sramii19 - which • anchors framing stud track directly to the .building a,tructure above (for walla perpendioular to :the foist :framing) and by strut or ceiling bracing for all other , walls: (which do not intertsnot ►structural compor1enta) . : Therefore, the site MOditiCation acceptable. Reopeat£ully� ARCHITECTUkE / M PLANNING / INTERiUR 4E H. 7452�2nJ ;w4? dOI H VP Ik / �3!!tit 4M.fl3 i<,4c,$IMt4, I3l4)46 0a9 to the. tee .il da p1.61 is PROJECT: 1�. ' PERMIT NO. 1 SITE ADDRESS: / I L e 1 l s , _„ DATE CALLED: / f TYPE OF INSPECTION: A/0,/ntiA.- DATE WANTED: q-- a ' m ' SPECIAL INSTRUCTIONS: REQUESTER: PHONE NO.: 9-3' - 78737 INSPECTION RESULTS /COMMENTS: • • ,- , , -e 7 - A �'c} -(_ -) DATE: INSPECTOR: 12.44., - 'Z,•/,,4. , C!?Y OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTIOk RECORD 6300 Southcenter Boulevard - #100 Tukwila Washington 98188 Permit No. c em u s 7 464, Signed CITY OF TUKWILA Building Division 6200 Southcenter Blvd. Tukwila, WA 98188 433-1845 4:7/9 Date Job Address /3 3 CORRECTION NOTICE The following items are found to be in violation of Ordinance and shall be corrected. Building •ftiala / nspec or City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 TUKWILA FIRE DEPARTMENT FINAL APPROVAL . FORM Gary L. VanDusen, Mayor Project Name 0'' Address i 11 •.» > Retain current inspection schedule / shift inspection Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Approved without correct ion. notice Approved with correction notice issued 3 . • Authorized Signature Date Control No. 91 Permit No. 6 "7 / l Suite # FINALAPP.FRM T.F.D. Form F.P. 85 TO: FIRE PREVENTION PLAN REVISION TO PERMIT NO. 6719 PERMIT HOLDER SUBMITTED A REVISION TO SPACE. PLAN ON 28AUG91,:HAVE REVIEWED NEW PLAN FOR EXITING REQUIREMENTS. NEW LAYOUT WILL INCREASE THE CALC.'D OCCUPANT LOAD TO 24'. REQUIRED NUMBER :OF.EXITS REMAINS ONE. TWO DOORS TO EXISTING" CORRIDOR WILL SERVE THIS SPACE EXITING REMAINS 0. K PLEASE REVIEW FOR YOUR INFO, AND COMMENT IF YOU DISAGREE. DATE 2ES 4utr 11 I I PROJECT NAME Cart. ADDRESS ! 0 r t•A% ARCM hCT OR ENGINEER PERMIT NUMBER 4 ‘711 PLAN CHECK NUMBER TYPE OF REVISION: SUBMITTED TO: CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * * REVISION SUBMITTAL * * CONTACT PERSON 1 B.DI • t a% ^' r.+eHONE RECEIVED CITY OF TUKWILA AUG 2 8 1991 PERMIT CENTER .244 -ol$b (If previously issued) a0 :IS Cri it.ire✓tiotz ebom. c.0nIF'iewurtA4-1 0J . A2tximiCe rti r2k-L. t f■L Gtr (-r g... t ►.l 156 cat. 0 CI—L) P t+ ... laVtArS - C t . Srh�..tw S5 k - 6gsr. .�L�► . wrap Emx ■ �._ :..► - - Li r • D L 1 111 t)G ( UNDER SESIAAXE Ps i&1r) ''IAMB r w,)117 t DIFr eattl.1f CaC-tcr., SHEET NUMBER(S) A o eJ A 2 - "Cloud" or highlight all areas of revisions and date re ' ons. d CITY OF TUKWILA 6200 SOUTIICENTERBOULEVARD, TUKWILA, WASHINGTON PIIONE N (2061433.1800 Plan Check #91 -267: Dr. Eugene Hunt 13030 Military Rd S #208 THE FOLLOWING COMMENTS APPLY TO AND BECOME PART 1F THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER j ll . 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296 - 4732). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (872 - 6363). 4. All mechanical work shall be under separate permit through the City of Tukwila. 5. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 7. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 8. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 9. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washignton State Energy Code (1989 Edition), and Washington. State Regulations for Barrier Free Facility (1989 . Edition). Gary L. VanDusen, Mayor 10. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any . violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. "X" REQUIRED INSPECTIONS PHONE DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 x 7 Framing 431 -3670 8 Insulation 431 -3670 X 9 Suspended Ceiling 431 -3670 X 10 Wall Board Fastening 431 -3670 11 12 • 13 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431-3670 X 17 BUILDING FINAL 431-3670 CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: 13030 Military Rd S s BUILDIIS3 PERMIT INSPECTION RECORD (Post with Building Permit In conspicuous place) SUITE NO.: BUILDING PERMIT NO. D ATE ISSUED: PROJECT: Dr. Eugene Hunt CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (INSPECTOR COMMENT SECTION ON REVERSE) INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. Ar 3. SLAB - If structural slab or if undersiab insulation Is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. ammo PL -,N REVIEW COMMEIV , S Plan Check No.: CI I --ZP7 Project:, .F.-06F.-NE I4Utr REQUIRED INSPECTIONS No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277- 7272). All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). All high strength bolting to be special inspected (Sec. 306, UBC). Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by that agency on the Job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7, Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the Jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. A Certificate of Occupancy will be required for this permit. 1. Footings 2. Foundation 3. Slab /Slab Insulation 4. Shear Wall Nailing 5. Roof Sheathing Nailing 6. Masonry Chimney 7. Framing 8. Insulation 9. Suspended Ceiling 10. Wall Board Fastening 11. 12. 13. 14. Fire Final 15. Planning Final 16. Public Works Final 17. Building Final PL -,N REVIEW COMMEIV , S Plan Check No.: CI I --ZP7 Project:, .F.-06F.-NE I4Utr REQUIRED INSPECTIONS No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277- 7272). All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). All high strength bolting to be special inspected (Sec. 306, UBC). Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by that agency on the Job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7, Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the Jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. A Certificate of Occupancy will be required for this permit. City Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review Control #91 -267 (513) Dear Dr. Hunt: Gary L. VanDusen, Mayor July 18, 1991 Re: Dr. Eugene Hunt- 13030 Military Road South, Suite #208 The attached. set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10 B:C).dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) (UFC 10 -1 (3 -1)) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.6), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.6) (UFC 10.301) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher," with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC 10.301) 2. Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 10.402(a). Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) Exit signs shall be installed at required exit The Tukwila City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 cc: T.F.U. file. ncd Gary L. VanDusen, Mayor doorways and where otherwise necessary to clearly indicate the direction of egress. Signs shall be of a contrasting color with the surrounding area and shall have letters not less than six inches high with. a minimum letter width of 3/4 ". (UBC 3314) (UFC 12.108) 3. All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored . or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) Walls and ceilings of corridors serving an occupant load of 30 or more shall be not less than one -hour fire resistive construction. (UBC 3305(g)) (UFC 12.105(a)) All interior wall covering materials shall be fire- resistive or shall be treated to be fire - resistive, so as to result in a flame - spread rating as required by UFC Appendix VI-C tables 42A and 42B. A certificate of the flame spread rating is required to be delivered to the Tukwila Fire Department. (UBC 4204) (UFC 10.401) This review limited to speculative tenant space only special fire permits may be necessary depending on detailed description of intended use. Yours truly, Fire Prevention Bureau CITY OF TUKWILA Department of Community Development - Building Division Phone: (206) 431 -3670 PROJECT: t.k ADDRESS: 1' D M L Them 7 9! DATE: OCCUPANCY GROU TYPE OF CONSTRUCTION LOCATION ON PROPERTY % /G BUILDING HEIGHT /# OF STORIES re *1► FLOOR AREA OCCUPANT LOAD NOTES PREPARED BY: A 1. EXITING REQUIREMENTS Lae r .:. AfA di _I; 1 ire ,• • • • DETAILED REQUIREMENTS OCCUPANCY TYPE OF CONSTRUCTION PART V, CHAPTER 23, U.B.C. 140 0 CHAPTER 51-10, W.A.C. 4 (L a(' ,` N J 3 j . ma c. - 7 ©�k I �M CFO � PLAN REVIEVi 1 w_oce 3e 4 5 F1.O?- 1 1 175 PLAN CHECK NUMBER 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 DATE: p 7 0/1 11. g er r;Y egg • � s I SCOPE OF CONSTRUCTION 0i a, Obt LI buiiding /mschanicalielectrical:peermits B. As -kilt eurVey Ot eisting conditions 3. Nell d taseltng (resin and *existing well codifications 4. Floor, Wall and ceiling patch and finish repair aim required 5., New or revised interior finishes as mChnduIed 6. Coordination of Owner ;:2'eavided equipment and furnishings. Provide Cr schedule for Owner review. 7. Coordination of sub -c ontraotor trades, inspections and Wilding Cede vanforsance, 9. Project *arterial i installation shop drawing submittals 9. As- built'drawing (blueprint set) documenting the position of all site utilities 'installed, modified or encountered, and field revisions to building design /assembly as approved. ;1C. Subaissiot of Olose -out material, as outlined below: a. Guarantee* (1 year general construction plus materials /equip) b: Equipeent operations & maintenance manuals C. SUrelua saintenence stock . Ceiling tiles (2% of project image) . Paint & Stain finishes (1. quart minimum per color) Mechanical • Veamign/BUild 1. As - built survey of existing hvac utilities (for connection/ revision) to bs modified by work this document 2. !(vac system deaden, procurement and :restalletion for adaptation of axistins mechaCnical hvac system. a. Syatee* shall include: .t Meted return with acoustical control lining /layout, (for transmission from room -to -room? or common plenum with acoustical return duct sound control elbows b. System Zoning 1. southern exterior rooms 2. Intcriot rooms 3. Procedure /Lab sons with independent exhaust fan c. Thermostatic controla /system operation:, 1. System shall have contralti compatible with the central Alb ,i Z I in f0$ 7a1 • lOb li3 it a- 104 qb 4} /02 .......AMO.", 2.4' • C. DI TO ---1 MKE title 1 , ..at - o.•! CO) CRS D.VMPSTER PACK eeeeee • - -. • Neehanicad - pssigf /Build Zcontiratd) 3. Mechanical drawings as required for owner review and design approval (including shop drawing submittals), per*tts and construction 4. As- built'drawins (blueprint set) documenting the position of all utilities provided this Contract. glectricat. Design/Build 1. As -build survey of existing electrical panels, circu ee and coaaunicetion spate's in area* of remodel construction. 2. Service load analysis, expansion, panel circuit consolidation or service upgrade as required for. now loadins requirements 3. Electrical outlet circuit,. mechanical /electrical equipment circuits, hose run revisions, wiring, conduit, fittings and devices 4. Electrical lighting fixtures, wiring, switching and circuiting as required for lightins as shoun by contract drawings. 5. Placement of coas+unicatian (telephones, PA) and date call /ceiling outlet baokbox, Junction boxes for termination within ceiling Cavities conduit (wall and inaccessible - ceiling routing; and where required by code for shielding /str;ecture penetration) for Owner provided communication equipment wiring and installation. 6. Electrical drawings as required for owner review and design approval (including shop drawing submittals), permits and construction. 8. As -built drawing (blueprint set) documenting the position of all utilities provided this contract. • -- x;S I) G P?k 'cE ROADV\iA) . t ;JNCRETS TRAN5FORMER PAP. SEA 70 ' ' 1. • . . • • !>F0 3Y•D.'a'. _a..k� p or CRE :' AT t . Ce�iOLSR 7 ; .7 ekm s �o��..�`, � ?v a s • • 65' a KAN OVERALL SITE PLAN Riverton Medical Center ! 40' - -aereasia ' 1 Hightine Community Hospital Riverton Campus ACS . RAC" REL OCA PAS! I N TO E Re N W EC7C/e P PAVI NG' PAVI NC-6 • 1 tXl,Tit�l G. , TO REMAIN "r AR L,.; v- HT • • i FIN. PL. �1.►. = 92.0 ` 1l1 Check approvals are isSion$ and approves of e the violation of any Receipt of contractor's acknowledged. 1~1t 1 �r "ltd PARK I M LI __- I @ rb2. - t i.C 5° P • ,,--- •ROCKERX' AT 17GE ' 'TARP LIGHT 7 OF a'X191'1N& PAS /tNC& PROJECT Txx).Ra PROJRCt GeNZR: .-I • 9 CODE ANALYSIS D. HUl1T OFFIC1t Riverton' Neldicsl Center Suite 208 HIGHLIN'S COMMS'R''Y HOSPITAL 16251 Sylvester Road S.W. Seattle, Washington 98166 Re r 3 nta ive: R ch rd Wedi Ati C i p a s Associate Administrator 1244.0180 APPLICABLE CODES: City of Tukwila Jurisdiction Uniform Building Code, 1.908 edition Uniform Mechanical Code. 1968 edition Uniform Plumbing Code, 1938 edition National Electrical Code. 1907 edition Uniform Fire Code, 1988 edition Life Safety Code, 1988 edition National Fire Protection Association (NFPA) 101 Tukwila Fire Marshall Fire Protection Requirements Washington State energy Code, 1986 edition Washington State Regulations for Barrier Free Facilities, ZONING INFORMATION Project Address: 13,030 Military Road South Seattle, Washington 518168 Tax Parcel Number 162304- 9171 -05 Property Classification: Project Classification: Parking Requirements: Parking Required: (31,719 gsf x 1/400) . Standard • Handicap 2% required Parking Provided: . Standard . Handicapped LEGAL DESCRIPTION That portion of the N.E. 1/4 of Section 16, Township 23 N. Range 4 E. N.K. in Ring County, Washington, described as follow: Beginning at a point on the south line of said :sub- division 561 feet east of the s.v. corner thereof; Thence N. 0 "E, perpendicular to said south line, 184 feet to the true point of beginning: Thence N.89'45'43 "W, parallel with said south line, 207.50 feet; thence N.0 "E. 210 feet; thence S.89'45'43 "E. 121.0 feet; thence N.0 ° 14'17 "E. 215 feet; thence S.89 ° 45'43 "E. 62 feet; thence S_0'14'17 "N. 215 feet; thence $.25 ° 31'53 "E. 96.61 feet; thence S.0 °14 "W. 123 feet; thence N.R9 ° 45'43 "W. 17.50 feet to the true point of beginning. P.O Professional Office Medical Office - Approved Use 78 stalls 2 stalls 106 stalls 103 stalls 3 stalls 21 69 w 1,59 ee 80 stalls } • eeieaeeeoeiaeeeeeO , Plassification: ls Tone: III District, not applicable ,0Ccu Typo • -2 Medical Office • 8 -1 Parking Uc rago Cons tion Types V -N unsprinklered (exce pt garage)' Aable Building Urea 36,000 e.f• Area: 8.00O s.i. . iple Floor Increase 8,000 s.t. 00. x 100 ?1 e Ye1'd Separation ihcrease 8,040 s.f• ' -20')x 2,5% x ment Exssption i1, 00 is 50% (yard s h) s.f Actual Building Arose 3 1.719 s.f. • Ram rent Parking 10,829 s.f . First Floor 10,633 s.f. . Second Floor 10.257 s.f. Tenant Ie rovesrsnt Remodel Area: yglg e - f - Area Separations Not Required Occupancy s$eparatton2 . Garage to Storages (81 -B2) 1 hour . Garage to Office (B1 -02) 1 ho Construction Fire Resistive 5equirewe . Exterior Walls Non - rated . exterior Wall Openings Nun -r . Structural Frame Non -r . Interior Partitions Non -r . Shaft Enclosures 1 hour . Fluor /Ceiling Non -rated R oof / Ceiling Non -rated Fire P Fir al arls requirements as mandated by the Fins Marshal: monitor of .existing basement (garage) sprinkler system =ow say COT13 INroamatiON Envelope Requirements (chapter 6, performance approach) envelope Insulating Requirements (R value) Required Provided . Ceiling/Roof- 30.0 30.0 . Opaque Walls 11.0 19.0 • Window Glazing (double) 1.7 rein 1.88 . Window Area Allowed (sax) 515.2 s.f. 3275 x 1,610 (floor arms) Window Area Provided 'Infiltration, mechanical and electrical systems to comply with applicable energy code standards -RELOGATh Y.AFI P LIGHT. 9011.01191 IINVORNATIO$ VICINITY INDEX • • 0 16 THS INCH 1 ;.;, :.. ,. :s ..r - _ -;, it .y' �. .,.''z ,r. 4. <: S hC - .:r'• IIIIIIIII'IIII+I PII'1`1I1I1I1I1I 111111111111l1lll1111111111111111111111 11 111I1I l� '' X11111111 ,l►1lI 10 11 MAK INCA 12 2 3 4 5 6 7 8 9 NOTE: If the microfilmed document is less clear than this notice, it is due to the quality of the original document. 06 6Z 8c: Le 9Z 5d e7Z CZ ZZ IZ OZ 6L 81 LL 91 G1 VI CI ZL It 0e. 6 8 L 9 s i C Z I oo o IIIIIIIIIIIIIIIIIIIIIuIllulII11III► Ii11IIIIIIIII1I1111111 ►6111I1 iillll!1NIIMIIIIIIIIIIIHI IIM 11111 I0 111 1 1111 1 1 ► 111 111111111 I 11111 1 1 u11 1 111 1 11ubIl11 .10111111► 1111► IPIIIII111I111I11111111111I1IIIIIiIII11 111111111111∎ 1111I1111IlIdlul !IIlIIIIII II I I1 • BURIEN u z Al • SITE PLAN, CODE ANALYSIS, LEGAL DESCRIPTION • i •• N 94.41 s.f.. HIGHLINH HOSPITAL RIVERTON CAMPUS CITY OF TUKWILA APPROVED s p 19 1 BUILDI • I' lSION RECEIVED CITY OF TUKWILA AUG 28 1991 PERMIT CENTER KOVACH(OVIT PARTNERSHI eatemealeatemeastranereetrearearate • ARCHITECI RE MAST-£R NN1 - INTERIOR DESIGN 7415 222nd St. S.E., WOODINVILLE, WA 98072 (206) 485 -3838 FACSIMILE (206) 486 -0999 ate► /�It Rectsaco4 t w r is Rev. e • CC e • owe • De setip,aa REVISIONS: 1 DATE ISSUED: I DULY 11 DRAWN BY: PROJECT NO: DRAWING TITLE: DRAWING NO: CHECKED BY: 4 Tics, >.. DOOR Room - Name 0 •. Size OPENING IIR'M SCHEDULE Door Frame�' Hardware , Remarks ■� North - South . gleinoIIini,.LI Met ' " L I Sill �. t rcul Stop Neat( art. - R 1L REcJIPr I r EZIFOr Atifs 1J8 r 6 I P r M nJr Ws 8 ale a I cc we, Exisr'• � R f - 8'6 �� a Gil u P r �iF WS . OD _ D - E$1 II 3 ExAN 3 -" 2 NW' ctr I r4f r Pity ExAt1 3 EJ(AM 4 F ' F :'iii�ts • y - "- ra - ni A n 1111111 A.Ir2 Pi�f r , : m) D : a A A a _____P r 4 , 1 As iM CI r 1 r) r 11 1 6044 IM i4 ft _ LAE, LA r _._ __, 4 ofria a 123 .'n1' (Lif i1122Gril 7 6 ExAir) LA 4 MT Pair --r--- i ae aritf PE A t�LA I t. 10 Lo t* _.. _ A e ft 1 . D 6t, Exist AI1.3 Qty fx (1i6 f►Jf C as 4r At_r11I 8 te ; Act di 8-• r,FFitrE I • .11PA ExAM I FQ - / ►_ r1s _ i i . ExAM a - 11211 • , ". t16 6 14 8 . ' i ,,e B1 T rt P f„ i Acf 1 8.4 2 M PAttir srmre(R1r1 2 0 7 t 8 a e El 4 �� - r + 13 . ThIL,E " H D IEM 1111 r%Jr 4. 14 c *iri oo i 7 -,,,• 20 L 1 IN D ( 1Tt.si U 0 s Y (o turd om r.'L ; - ∎� . ._ _ A►1r61} DEThIL a . RO FINiSH SCHEDULE Room, No. Room Name Mil= Walls Collin • lag ' Trim , Notes �>A North East South . gleinoIIini,.LI u izri 11ioni V at I. F nis In s i - - R Lids 6usr -- EY.Ip 9s - W Oa I r EZIFOr Atifs 1J8 r 6 I P r M nJr Ws 8 ale a I p r -..r cc we, Exisr'• sir' Pt-Ir Mit a Acria. Act t i Acr ir MI* 8'6 a Gil u P r . RO FINiSH SCHEDULE Room, No. Room Name Mil= Walls Collin • lag ' Trim , Notes �>A North East South West gleinoIIini,.LI u izri 11ioni V at I. F nis In rr I r I PT I Vc1. - R Lids 6usr -- EY.Ip 9s - W Oa CM EZIFOr Atifs 1J8 r 6 I P r M nJr Ws 8 ale a I p r -..r cc we, Exisr'• sir' Pt-Ir Mit a Acria. Act t i Acr ir MI* 8'6 a Gil u P r RE(EPr 51u.1 It 8 ` life) II ExAN 3 -" EA1( 4 NW' ctr I r4f r Pity 1.6 En �a F ' F :'iii�ts ' fins r1 11Jr P+Jr ' Exisr E'4 0ws A.Ir2 Pi�f r , : merai tcr +L 8 • B 1 e�� OFI`K.EZ 6044 vGf LAE, LA r vsF ore 6 44 6M 123 .'n1' (Lif i1122Gril EttsIr s 1 MT Pair Act'L 18 pAr'<I 8'c' oFFIc. I :Mk VC .r R e ft 1 . Alf 6t, Exist AI1.3 Qty fx (1i6 f►Jf C as 4r At_r11I 8 te ; Act di 8-• ExAM I vt:r Exist r1s li act 4 1 8.6 ;4. rot to RA A • , R R t16 6 ' �r..] 8 . ' i ,,e B1 T rt 11• • 6 i Acf 1 8.4 PAttir srmre(R1r1 2 0 7 t 8 a e NN 0 1111 EAR EAST lo1Jr,1 - tlnu L 1 ( 1Tt.si U ji. DooRlyre. AseREVIA11O I J: J 4 Ni I 44 I i•th TAP• y1A5S t 14 tJD . 5 - of coley F sa r, / FMS 'I"f, eE t foR M Et orZ FirlIStl As Sr.11E0+.ILED c 12 � Ge�RPE11 cm �(� odr( F cF �' I- I I F -alb u v .rr 2 - M EDF E D 713 5T L R 2'$t" row° RIJ eeaIE 2 BrtSE {,j/o m-, Ro(PE.+ ao VGr `IIJTt?1LE iesik -MA 1'iiolkit'51`Jil GENERAL NOTES DEMOLITION NOTES t. Demolition notation represents the general scope of demolition and salvage work. The drawings do not necessarily represent all existing conditions one features (Architectural. Mechanical and Electrical). 2. The Contractor shall verify all existing conditions, diaensions and utility locations prior to construction. Notify the Architect of any discrepancies In existing conditions from that represented this document. 3. The General Contractor shall be solely responsible for maintaining free aceese of owner vehicles end personnel to the site and building areas during construction. and for maintaining adjacent suites, corridors. building grounds end streets free of dirt and debris which may result from construction operations. 4. ell adjacent building areas shall remain occupied during demolition and new construction. The general contractor and his subcontractors shall trice every precaution to insure the safety and limited disruption to ongoing operations which shall include. but not be limited to: a. Temporary dust partitions to adjacent. occupied areas b. )Encapsulating construction areas within a one hour fire rated partition C. in the event that a •itillty shutdo.e is required to perform contract work. the contractor shall notify the owner a minimum of 24 hours in advance of scheduled work and s6ail perfur■ said shutdowns during building off - peak hours. 5. Demolition acttvitles shell remove all existing building' features to the extent required for new construction. Store features scheduled for reuse or owner salvage and dispose of all non- salvaged materials (refuse) off site in accordance with applicable codes. 6. For construction activity adjacent to or Including the building structure. do not impair the structural members design strength. bracing or connection to other work • by cutting or boring operations. 7. All demolition which requires mechanical cutting (to incorporate new construction) shall be porforged by sowing or grinding tools, not hammering or chopping tools. Core drill openings throtreh concrete work. 8. Construction srees which shall remain occupied (oper- ational), existing building finiet:es for reuse and owner selvage materiels not scheduled for Contractor demolition or relocation shall be protected from construction work by tarps and /or berracades as required. Confine construction activities to those locations where contract work has been scheduled and provide whatever meeuures are required to protect owner personnel end facility operations. h coat iZ �-¢-- {. E►tISr1J(1 D . IIE4DI:f� -t-° i NEAoER - Etlstll,k Exr N z$4, srt1os @ i� 4.c- Cpl tft I Sri � c) ALL - _�_ - 03L. 2k4 STtlD ARI1 1EXTH Roof ikti5SES r g 4x(4 pf si` ? Jbu II � (Miry E) IR4 fi HEADEK ABSREVIAT14dS 1.10 coop- 7 PLy '14ROI4GOD vedEE. POOR Sol! D Con., WITF1 VOJEEi� To MATeli N91Jisii A SPEt1P1ED , To idryEetiidsER sa , IrA RasA Sect E..S Ftu►I1E - 0).44 tJ ooD Flo 11 cesIce,1 to Marsh 6L1 5rA�JoARD 1111 16 NOLLOII) METAL FRAME. (D8Llt� E61r DE.5 N 4 �.2 Re IN To !JAIL. FRAME SIIAt.L 6E WELDED C.bRt cogst12 10 f I11TLgio1`Z �Ko(rI,Jc oft ARRoVEW Sol IJO t»MME I (t GoAf1 Rh" Jo . i.Jooc SEALS �e I rriE.12 ' 2 Gc ArS LATEX SATTIJ 04 - strEet. PRIME § (A f$ ALkN(D 5f- CiLOSS/co ?o WALL. SO 14ARDIAorap To MA1 r edIL.Di 11 STAik*gp IV R INKS I GOAT' - rRAils FaRAIJr rTAIN j 2coATS ti iJoLJ- '(E LLo1J VAVIS W Act 4416 YISF dKNERAL NOTNO 1. All dimensioning is to face of of now walls (gypsum wellboord. column centerline. All disensi over scaling (drawing). 4. All elevation references shall unless otherwise noted. IIIMIMIMMI STRUCTUR "_•_____ t:A411 bi A1t'rtu1 %1 1'MAc o GEru 4(00 teas PAIt.Ii COA?1NI4 - I c4Ar PV PIQitAL coATS LATt' sAftN MI II � MIIJ v E to Aci;IEy uiJJfoRM 'QVe:.RAME -' otEs F' ' V DE c rES s/kbE c lv(� - ! j 2.. t tJLE►Jt M(tZs A toted 1JodJ • FiRE RATED SJs''►JDED MO - Oo1.111 cx 4JNit'� /%GOJSTI *LE Eat, r3uX1. sTkJLl O Acr+i - 2x1¢ yRID AGr t2 • a,ea ( io V '( qr 1th4 WA`L60ARD TIM Se TAtrrD sA1JDED vI t. St+E.i-t FLOOtz'y Artr4siRolJM II N%learrIE5 1 I 8ee0 5 1. The General Contractor shall furnish all labor, materials. equipment. transportation. and services • necessary for the completion of the work. All materiels end installations shall comply with applicable codes and governing regulations, end shall be of first quality materials and installation (industry standard). Materials shall match building standard design and finish throughout unless otheruiee noted. 2. It is the responsibility of arch contractor (General and Subcontractors) to obtain all governing permits and in- spections. and pay all use /service fees as a feature of their contrsct bid. Additionally, it is the respons- ibility of each contractor to review their rspectiver wo.k and coordinate ti.a integration of their work with other trades. existing walla, the face concrete) or structural one shall have preference be to Top of Plywood Floes* S. All door and relite openings. unless specifically located (horizontally) are to be centered on the wall face, two stud iamb wall return or located as noted. Where a door or relit* anchor to an adjoining wall stud pair, the stud providtng anchorage atachment to the free, shall be a 20 gauge stud minimum. 6. Doorway openings shall contain door, frame and hardware as scheduled. For openings not scheduled. provide gypsum wall- board cased o,:ening with paint finish to match surrounding walls" 7. All ancillary rooms (closets, veStib•rlee, alcoves), wing wally, or freestanding column features within rooms constructed and /or remodeled as scheduled by this construction contract small contain finishes (floor. wall s ceiling) to match the primary room finish in which they are located or as scheduled. 8 All fixtures, equipment or furnishings scheduled for salvage and reuse or equipment supplied by the owner for installation this contract !FDIC) shall be coordinated by the General Contractor. The General Contractor shall notify the Owner. by way of a CPM Schedule. of required Owner material deliveries to maintain the construction schedule. elc lsTI t 8+L1►lc g r an lrr IJf c.m11r. 6L VA ICA1t I4 EM rip olf b of . 5 t9 012 sr 45 irlta c(E'ES@ rZb'Ip.f. 14D i etk.ifrloiJ tk A S r •I F1ED swanam Tire. ' e. HARDWARE 1(1 W. _X 1 i'OCKET DOOR FRAME PACKAGE 2 RECESSED DOOR PULLS 1 RECESSED EDGE PULL LW .2 1 -1/2 1 3 1 H1l14 -3 tiPN. 4 1-•1/2 PAIR BUTTS 7 PRIVACY - LE /ER 1 set SOUND GASKET FLOOR STOP. 110)4, _$ H17416 PAIR BUTTS 1 LOCKSET - LEVER (office) ice.) 1 CLOSER 1 FLOOR STOP 1 net STOKE GASKET DOOR HARDWARE GENERAL NOTES 1. All hardware shah be handicapped accessible lever design in manufacture and finish to match the existing building standard. The General Contractor chali procure the services of a well established, reputable. hardware specifier /supplier, as a feature of this construction contract. _.o review as -built hardware specificat .r standards as established. All hinges shall be non- reaov.i bl i pin aesign in configuratlo.^ '.o provide door opening swing as shown or anticipated. 3. Provide door closers with adlustahle key/ valves for speed and latching adjustment. 48 04 t a i cl t 'JALs3 PARALLCI. ro ..JOlsr tad. cosh. rya .loi u4 IWZ -14ei HAILS i I PARTI'T'IONS PAIR BUTTS PASSAGE SET - LEVER FRAME SILENCERS FLOOR STOP (AIR BUTTS PASSAGE SET - LEVER PLAST7:7 KICKPLATK (10" x width) FRA•.- SILENr"S !,00R ST :•b PAIR BUTTE; LOCKSET - LEVER SOUND GASKET FLOOR STOP CiEJJERAL 1 yctJ v*J rl,y 4c roR r C sJs cotlitenc.f2� 4�' IALL 14 LJ 4 CoORDI,1btrrt. cohlsr, L.J : o f 1i0E FLOoR BU.oid II.kLJOi�(4� F411511 J REP R aJ12ED ro Ac.co.1PL15i1 at:1a F or office) `- IJooD as (l ernt 81.iEt is c. 4u1J I As O4 W/ EQUAL BoRoE2 "HIES, 1YP 7 -zs c�, s p Tik�t k (cltaiE!E D To rvipi o Ftoort e- Pc. xKE44s e O 4 e To i jE)JP Fat i1M.L `XFJ. S • 8 J4oW cagt4E, Lir or S S SaIL'LF 0 r Folk �1I EaVIC,E ACC. 14014 - 1- 1}At - / A<.L.ES5 - JEd 11lt0�! - Mi� TGt1 SIZE OPERATiOi4 of Exlsry (/ 4 TILE eicEA1 ' Fw:14E IA/ ll ( 4 Res! �( o0,AtJ NI °RrI ALE. 61/4.1(80. r .xIeily Li,J I 1 �r7VAIT�NG d 5I YERIFy If c1�D t ,LL mss: • eAr'tR of -� 'AN D° mou4 ro / st4okre J tag ye. LAB '5'.3dc ";11,(1j .�oFFI r sour11 yRlo ro -11o1D D�1; Tiy14r ro (411(1. 4-10 ctR __ 7, f BILLING 'Y�4IrZIT e 1 I a 3. e.oI r W Arj t 1I CI (� r 87' .'\ ttr FILE. �! sl +Elf -. RECEPTION MIJ v 11 _ f ir _ -_ Gc __ -- • FAX i I b ? � Il 4% CEILING PLAN I/ IN I.E SHE( I - 0 oFr 2 402 i i 4 Aft ESS Done (rb Fo) • I E1cI y L.1140.4 FXAIVI'5 urge /z FLOOR PLAN f st2 s sEE LLFr S J Ar I ExI57I4" OLIO( R 1l %tor t.° smact. A IL 0 to INS INCH 1 2 r s. r tI4'J IIfjIiIIIIIIiIIIIIIIIIIIII II ;IIiIII IIIIIIIIIIIIIIIIIIIIIIIf II 1111:;"111111 ( 3 4 5 6 7 8 9 10 11 1m�I� 12 NOTE: if the microfilmed document is less clear than this . notice, it is due to the quality of the prlginal document. 0€ 6Z se Lz 9Z 9Z 7Z CZ a2 I Oz 6I 8l LI 91 St ti E:1 ZI IL pl 6 9 L 9 S 7 C Z L ww 0 IIIIIIIIIIIIIIIIIIIIIIII1111! III! LIIIIII IItiiIIIIII1111I111! IIIIIIIlIIIIIIiI' I !!!I!11IIIIIIIIIIIlIILIIiIJIiii itIIit!IIIIIIIIIIIIIIII! Ili 'IIII!!�IIIIIIII{II!IIiIIiIIii IIIlIIIIIIIII'IIiii IilllIIIIIJIIIIIIIiIIIIiIIIiiIIipiiit ,,ii,i !!II!IIIIII! IIIII IIIII' IIIIIlII!IIIIIIIIIiii,IIIIII!I I LEGEND ! JLE R04 (E.lLilJy ylta thy- III Acoi)srlurL TILE. scIIEOJLE. c �15Tl 1 I j( 1 o'EE $PEEL sruo E u iJ .JoIS7S e 21 a/ sEISM1iC. BRAGIIJ 1-b TIE S`1R'U GTl1Qt. A•VE alga(' Fit.lts 4 ra e.e 3i LoWe 11-144 511sr,E11DE0 CiR;o A�a,�I1AGE Pklalr FiiJls14 A'a ScHEOdLED j� I x kEcESSED FLJopEse - Edr llyHr FII(TtiRf. E4LIAL. To DAy- t3RIr if r O+rsl 1! VDr E.F-33- LI As RtAtion.0 21f4 REctss FLJOgesfEi•.J1 LI Iir I FIxertJ(2E. E•iil4L To gutLOII.Jy sto OFFICE EIRAAE tJ/ Poz1stAATie.. L.E�Is 2if2 RI<.CE•S D FLJoRESE.Et1T' Lu jf Fi )(TIME- At.- lb DAY - utrigr DESi(ciJI;lr vor GF- 33 O L LEGEND Ei( i Xrl1�� oR Fart* 1•0 Rfiolio .4 ORI( EXI'sl lfdy I01Au. in REYISEP FoR fEI�i r L FR4MI� i EL O1 tiaa. alt art FI (38 As SGdED DLJ L.ED EIJ E TERlog aQNoIA4 &ISr1N Au, - RRoDE. DoLJW-( 'SldD ��M PEi.JIt M 1 FA ��J Rereok To i . PortR� FuJIS ES tilKfol ExJSTI J Li Az" 2 L IE. sta. 1� srtlo F ttiv Ifobd.G• 9 I 1 EtAc. Sipe. - r U D 1.1 " Acne lr�tL_ ESA' T I� (ION CALJl 1(• N61-I f St.F1ELD. NEW 3 x4 i == cothiE sr silk) FF'AMId ° ray/ 'i` 1C E M 10 a-I silirc4 f?OM E. Adele IT 208 KEY PLAN SECOND FLOOR REGES✓SD IIIcA1•JDESUEN i FixrdR E1 LJAL. to CAPRI RMA 100c1LD LEIS 6W /14oJsiIj(J Te MArIF'1- 7511 Recess•ED II�l:Adoese. fr Lic� tir AX tR Eq d i.APRi ml LE W/ 146►;c ro MATtN 7' W sJRfMfc. E. N1O IJe'EO Tga.e.ld y c 1 r $PtiO REIRFORbEME4t c1.104hkt. 0480 G E EQ UAL.To �1gNT oLIEF, it 4o2S3( MAie -H1Ny TRAG t-It0I4r' 614k-14104° 614k-14104° IIIaI @ 42 "Aff' l CRY I C: 1 IJ�b l.li O LATT i'I d1SIDE. AflO rtJ ABIoV - F�Irj IsI� F f 5u4 iJ IJ 2 ZS you.146. STEEL stdD FdV IK e la" o.t ec rjrE tX oij Eatl'cs fA t0 . Ai6VE. GE III I.J U I NE snip W 1 yyr . &Fr L1 F� � D(PE Ib 5iR t a E 1 -lol�i t ,LL io IratlSi�n� FIOE- UAI.L- t Hills(,( rsR sc46.0t1L.E.. ovERLAy I4A s' 6OL O Til�t I Hit ARE RAND Ass► .M i341 1 DFi.I0 rJiq 4t1d E. oR EQLIIPMEr1r i.JIIIGF� 1 I1IG• I.IAiL ELEVArl4t,1 REFEt2EkkE. SEE CITY OF TUKWILA O(JI'LEX AJ fl.Et', X11 4 #I ts GPI ie.A P P ROVED 12 NEtt1N otc 1($ iJoYEo d 4 rL J( ourLEr; L4}hrE tALG1 NEIyH tli scr4srtaU p ThL) PI4O BIAx 1I .4 1, To fail: cAVITI I 12' dE.I(4 OR AV Nor'ED ELEc L4EIZ s&IProRr i4od 1r FOR ot-lph Z 'Ammo LIr- q11' o vie, AS SfSC.IFIE0 tJ L1 E f.Att s ear ) e iJ l r 1,1 e(8:1/21,111f. DO E. Ik n@ (� 4 u c '1t6' ALkl O P't4'161 IQ) SEP UILDIN Ir ISION RECEIVED s CITY OF TI IK LA AUG 2 8 -1 PERMIT ENT R t 1991 KOVACH /OVITT PARTNERSHIP 7415 222nd St. S,E., WOODINVILLE. WA 98072 (206) 485 -3838 FACSIMILE (206) 486 -0999 APPROVED: REVISIONS: DRAWING NO: 11zC i {J 1 1:C I'U RJ.: -4> -11:R PLAN N-1N( I 'NTFRl()R DF,SIC;N a•1441mrasmroo DATE ISSUED: 5 _1JLy A -2 I .. 1t7\ t. G ! n 8127/91 IM-oESly 41s104 Rev. B. CC 4 • Dale • Description DRAWN BY: CHECKED BY: PROJECT NO: DRAWING TITLE: