Loading...
HomeMy WebLinkAboutPermit 6722 - Lindal Cedar Homes - Tenant Improvement6722 91-257 lindal cedar homes 10400 martin luther king junior way south Permit 6722 - Lindal Cedar Homes '' • • 1 1: V 1: 1 • ` y ear 1988 SETBACKS: N - S - E- W FIRE PROTECTION: OSprinklers Q Detectors N/A UT ILITY PERMITS REQUIRED? Yes (th rough NC PtZio Works ZONING: BAR/LAND USE CONDITIONS? ZIP 98063 (] Yes xQ No CONDITIONS (other than those noted on or attached to permit/plans) ARCHITECT David Kehle, Architect • ADDRESS 12878 Interurban Avenue South, Tukwila, WA ZIP 98168 '- 'TT. Lindal Cedar Homes, Inc. "•` 725 -0900 ADDRESS 4300 South 104th Place, P.O. Box 24426, Seattle, WA I7dP 9814 CONTRACTOR Great Bay Group (PHONE 725 -0900 ADDRESS p.0. Box 4566, Federal Way, WA ZIP 98063 WA. ST. CONTRACTOR'S LICENSE # GREATBQ102D1 EXP DATE 4 - 09 - 92 ARCHITECT David Kehle, Architect PHONE 433 -8997 ADDRESS 12878 Interurban Avenue South, Tukwila, WA ZIP 98168 CITY OF TUKWILA Dept. of Community Development- Building 6300 Southcenter Boulevard, Tukwila WA (206) 431 -3670 BUILDING PERMIT NO. DATE ISSUED: SITE ADDRESS PROJECT NAME /TENANT Lindal Cedar Homes APPROVED FOR ISSUANCE BY: CERTIFICATE OF OCCUPANCY NO. Cc� as 10400 Martin Luther King eg E # X114 (? Divisio 98188 BUILDIt PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) OESCRt PTlON::;< BU PLAN:CH ECK: FEE`> BUILDING SURCHARGE :: TOTAL PLAN CHECK NO.: BUILDING OFFICIAL DATE ISSUED: AMOUNT :;: 419::00 DATE RCPT #i 9 8:1 91 -257 : PROJECT INFORMATION VALUE OF CONSTRUCTION - $ 51,000.00 ASSESSOR ACCOUNT # 03z3U4 9026 - TYPE OF 0 New Building ❑ Addition U Tenant Improvement (commercial) LJ Demolition (building) 1 Grading/Fill WORK: 0 Rack Storage (] Reroof 0 Remodel (residential) O Other: DESCRIBE WORK TO BE DONE: Remove existing office, remove one overhead door and replace with glass and re -glaze existing windows with insulated glazing cut in new window in avii cti np ti l t_iip pjpel _ TI SQUARE OCC. SQUARE OCC. SQUARE OCC. SQUARE OCC. SQUARE OCC. TOTAL TOTAL FEET LOAD FEET LOAD FEET LOAD FEET LOAD FEET LOAD SQUARE FEET OCC. LOAD I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of Iav and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. SIGNATURE: / DATE: 6/94/ DATE: 7- `4 _ PRINT NAME: S TS yF i j _ Q 'AVI /L[_ COMPAN ,eE.9 This permit shall become .null and word if the work rs riot commenced w thln 80 days fron issuance or it the work is suspend 00. ..qp: 000 for a penod `of 180 days from: ° the last Inspectlo ,eeoP PERMIT NO. CONTACTED 'inOs5hO -, DATE READY DATE NOTIFIED q BY: ...( (init.) BY: (init.) PERMIT EXPIRES 2nd NOTIFICATION AMOUNT OWING 4 !i , O a 3RD NOTIFICATION BY: (snit.) PROJECT NAME A t 1 4-0 P LAN CHECK n NUMBER "t 1 - 1 INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) F.400:* 4 SQUARE FEET OCC. LOAD SQUARE OCC. SQUARE FEET LOAD FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project.. D:EPARTEM BUILDING - initial review 7 5., FIRE PLANNING Pry O PUBLIC WORKS O OTHER BUILDING - final review - v4 - 7 - lbw 1 REVIEW COMPLETED (ROUTED) 1/ / FIRE PROTECTION: Sprinklerss �) Detectors N/A FIRE DEPT. LETTER DATED: "7/7/ �!'/ INSPECTOR: 5 INIT: "j' 7 / ,/��/ ZONING: BAR/LAND USE CONDITIONS? 7777 No l REFERENCE FILE NOS.: INIT '' MINIMUM SETBACKS: N- UTILITY PERMITS REQUIRED? MT: INIT: RO W' INIT: BUILDING . ?EMIT APPLICATION TRACKING CONSULTANT: Date Sent U.II PUBLIC WORKS LETTER DATED: TYPE OF CONSTRUCTION: Date Approved UBC EDITION (year): TOTAL OCC. LOAD SITE ADDRESS 10 C7 ktoci SUITE # h -t ll �-U'i1E72 .112. Utf. o. VALUE OF CONSTRUCTION - $ 4 II PRO NA ENA T t- 1 1.1 E2 .- 12. b /Y ASSESSOR ACCOUNT # X12 • -- r'} c2-o. b7 TYPE OF U New Building U Addition 14Tenant Improvement (commercial) U Demolition (building) WORK: 0 Rack Stora•e 0 Reroof 0 Remodel residential 0 Other DESCRIBE 120 RI WORK TO 3E DONE* � i� Q )O U +i" gun '' 1, x 6JEt bH2 ��f'rc t ij t ' b+.o PE( ge4 le). Vitaodvc t►► T;X1Skl(y "t1i:* ? Ftilet 1 1 EX 14 ' Sx- s h' - - -► 0 - - � % Wirirtmy wt1► INhuw v 1►�� or BUILDING USE (office, warehouse, etc.) NATURE OF BUSINESS: keastrtgo du) rtiujii,lelEis► : ef tliiat, (. GAa2 I MF WILL THERE BE A CHANGE IN USE? 0 No U Yes IF YES, EXPLAIN: SQUARE FOOTAGE - Building: Vila , Tenant Space: % hr Area of Construction: ZscI WILL THERE IN STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 4 No 0 Yes IF YES, EXPLAIN: PROPERTY OWNER IFI ; 2 12, I 1,1-. PHONE •72y. at, ADDRESS .41a ` 1b4-iri i P. �x V2 Cv `�, UJh . ZIP G I29- CONTRACTOR PHONE ADDRESS. ZIP WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT I. Yip it- PHONE 1 ADDRESS : I2251b Iiittaleaso bUe . ft • X96 • zip,' y 't`lgl!t ::t:::, " .. ��! �'.. C. 1* �T I~ Y Tk�l�T 1 Nl M. IN�1�. .'t'HI.� -:.': � y � � *�,+�}� j � �,�y � t �+ .R::.: ::6: �:%'%` i:< ��':?:.>:•::.: �► i�i�1Rf« 4i !.fi'�IJEiO:`�''..0.6 � ... : .. : <�in�.:4'%� ���... F 11� .......... : . ................................ . ....................... .•. .:• ........... .................::::,:::..:... . • • . si��•' � :•:':: >i ".E:'E':•:'• ?: ?;E``: �•: �::•:::.:; .: :;: E2% '< .......:..:.................... :.::..::.:.. ... BUILDING OWNER OR AUTHORIZED SIGNATUR: 1ip, I DATE 1 �_��14 c*,{ PRINT NAME �j l E LE PHONE 3 5,8 . AGENT ADDRESS imp" I w .0 .561,1 bJ .� . illigagell 1.6 t CONTACT PERSON p t* it PHONE 4 - CITY OF TUKWILA Department of Community Development - Building 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 APPLICATION :MUST BE FILLED . OUT COMPLETELY BUILDIk PERMIT APPLICATION Division A O ' NT D. -CRI: 0 BUILDING: PERMIT:FEE PLAN >CHECK>FEE "> OTHER : >'' BUILDING :•.SURCHARGE TO •Vd :qt: APPLICATION SUBMITTAL In order to ensure that your application Is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse sido of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is Issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED ( (' DATE APPLICATION EXPIRES COMMERCIAL . . . . „.... NEW : COMP., ERCO L BUILDIN(f3/ADDMONS' [i] Completed building permit application (one for oaCh ••••:•"?..'" L3 Assessor Account •••-: faikiwing • INvo sets (2) of th E Specifications .. • . • Structural calculations stamped by a Wathhigt�n Stt. �cen - . report Stamped by a Washington State liCentted engineer Topographical survay Energy calculations stamped by a WashingtonS*1000 :• engineer. of .arcl)ifeof • : : :.• 1 . 13 9id deflcriPOnn, il stamped by a Waihingten•Staiel archItoct which includ • • • • RESIDENTIAL 4,JB1k/IETTAL CHECKLIST •••••••••••'••• : ••••• 1 Slte P lail; ' . ■ d raw ing f4H.:":::•..?, ••• •••.. :•.•: ::::::::::: ::::'•:: •::: .:: :::'::: ‘• ].::: ::::::::' ::: W q•'• ...„..„......... ,..............;........'..i... . . ... .. .„........ .............. .• ................................• -•.,-.....:•••••:::".'••••: Ar chi te c tu ra l ' . ::,,,,.....i.::::,.,,.::::::::::::,:,....•.„,..: ...,......„,,ral drawIngs.; ...-„,,...,...: . : .. Mechanlcai • .,... ,..................„....„.::::„:..-.....„............,.:,.„...„. ...:....„....,........:,.....„.....,..,-,:::::::::.. Suy9I.P drawitigB.,•-••:.......•••,..,..,................,,::-:::?....::::.:',.::....:,:::::.,., .. Eteyaticyls... . . . ...„..,.... • e 1 c iea vi ! ng • ...,......:..l ..... .. , ..,... . • ' . . Landscapo Pit.!.. ''' • '''''''''''•' • - .0,.......-.„ for en tire pro ject} . „ .... . .:: . k3ted litil.it`1 permit !1; IiOnlen . .. ..: 71 .............::: i 7 MP ... , ,?.. , ...,!":: . ...oi::,:....v 0 .....,:,.::•!7 0 Fig s „....:-.....,;,,,,,,,,„, IVOTE::,9 0tilltipemik,50011paticiil ar, -- . - . . . • ........:„..:...........„......„..... ., .. .... .... •:.:s.c;b.,n*l .::::,::::::::'"'"''''""'"'” :''''''''' • .. . W s " : ...,.......„..„„..,.:„...„.....,..„::...:.::....„::::..,..2.:::.:,.....:::,:-.',.:.•''''.„'::'''''''''''.:*'::''''''''''''":''''''''.....''''''';';).::'...: . ftACK . .3T9R4pEs.'..!:::::: , ......: :::: . ':::...:.:::::::::::::::::.:':::::: .......,...................,..:....,......:...:-.. . - ...':....:.::::... , ..:......:........?.... , .. , ..,.....-,..m.*. . .. . . . ....... :. ... .........................:: .........- . i .,.....:::.:::...........:::::..............- • Co building permit applicatiok:: . ...".:.•,..:;,:.......,.........:.... • .•Assessor 'cF'9...Y Vr • .. .„ .... ..:........::::,::::..1.,:ri...o....:2)'t....0......0...........!:.......'i'...4",„.......!';•...'15'...,,..h,....,1r41.:•...•.:'.!...P.•:.....°..:. ud',.....:...9..:',..:....:,....:.;::::.:1:::::.:'...::::::.... 1 ::::::::.::•.:::::::::::::::::•::::::::::::::::::::::::••• ■:Eritir.i):•iipaciai:.Where.racl<S'Orillbe • doors :* .:Dlniertitio.fi*.°,f:04.P..,,,.„sy.,..,:::::::,.?•i'..„'„:::,'.:::::::.::!::::::::::::::::-:,.... . Onantspace..lieer.p.Inq .,,....„, NOTEHncIu de • .*ittl i • • • 4.,i.rrip.teeci.•§01.44og"pptmilipplic0490.,;(00049r.1 LJ Assessor Account Number • • . . Twasets.(2)Of..w.oridng• • Foundation plan Include' iii;cesitto Milan( • Floor • Roof plop Buikng Olevotioo or. oss7600 ton. siNcalro framui plans „.„ - 3.Washi ng to c i sfo to Energy Code data 1:00 mOleted 1.0)((6) sots 01 ito pan showing act.0„.. ,4(ki1ional topagraPkca,,. and spil;:lrifOr)74!tion may be requkod,funique Poen .... f or • : copv • . 124° • • ' • 1 Existing and p roposed .-- , of. " )Pn l, F , 0 4 . , Assessor Account Number •• so ng re fir. cot nett • • Tenan 'ar•Prtatnii::•Ad roo h. Palvm waHs jatio mid • New walis, existing wall, rne..31 • tru s is to, , perm. oon bi) ,::;1-p4QTE':. and Pi if ant noved and •• • , , • • ... • . • , 1. " • 1 • , eor " AssessorAocount Number llcenS�d .• ••• HESIOENTIAL REMODEL8 ComPloteCS 4 p4MritsaPP0030:(0 for ow" IsInictui) Assesso! Account Number • • ( st!.tif w9 NC, whiah. !NH • 8411 cline• 00 . 14 4 0 . 4 %titift:: . :1•:: : ::::: • • • • "' ••• ..„ ... . . . . • NOTE If any ut/Iity iik 16 to (70:cfpnp roe ype o nspe affippligilla Sp : • a Instru ions: ad. Q� dC • Date Wanted: . am. u� Requester: Phone No.: ;-' 00 01 1 ply'V +.1•rr."r�ic +w.N+ .�r�w+ ;444 4vw s.•.r+YwYr+r" Y ❑ Approved per applicable codes. INSPECTION RECORD .2 Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMrr (206) 431-3670 ❑ . Corrections required prior to approval. 'roe ; ` . ; Ype o nsped • n i .. ../hi dress: +t " '.e a l :.: Specie nstrudlons; - �.� .414/1/ lG, I � y Date anted: 1 1 y ( a r, .,, am, Kr i Requester: Phone No.: 1,7 z 5 b 6:1 157y: svi ... - r.�, ;- cam.... .h•....:••■••..:...r... • Approved per applicable codes. 0. INSPECTION RECORD C Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Corrections required prior to approval. (� $30.00.REINSPECTICN FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100.: Call to schedule. reirispection. (206) 431 -3670 Projecf- kJ( f(i � ol 0 / S T of In peciiqr�, . 6Glc Address: CaI Date le : w Special Instruct ons: 1� A „1,4,1e,/,,,:' � �lG (t' L .A15n . L i'1 DA) ' Y k,,A Sc ! : ate Wanted: D d �� . 7 _ � am; p.m. Requester: 541,11e... P hone No;: r COMMENTS: $30.00 REINSPECTION EE REQUIRED. Prior to relnspection, fee must be paid at 6300 Southcenter Bivd., Sulte,100. Call to schedule reinspection INSPECTION RECORD 0 Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT Nta (206) 431 -3670 Approved per applicable codes: 0 Corrections required prior to approval. CITY .r OF TUKWILA BUILDING DIVISION /6300 Southcenter Blvd., #100, Tukwila, WA 98188 1 I I� f 4 ') 1 r t 1 1 1� �• r, .• '.. � r' ., r, r �� r 1 . INSPECTION RECORD Retain a copy with permit $30.00 REINSPECTION FEE REQUIRED: Prior to reinspection, fee must be paid at 6300 Southcenter Blvd:, Suite 100. Call,to schedule reinspe9tion: e: .. O Corrections required prior to approval.cg Project: � � C a Inspection: t' Type of Inspection: � Address : l % ogob M. L i - Date Called: 1 f1-- 9 - q t Special Instructions: l � Date Wanted: /1 "" ,5_ j ' am p,m. Requester: , Phone No.: _ 6 7 t�D. T r� 7� CITY OF TUKWILA BUILDING DIVISION 6300'Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. O Corrections required prior to approval. COMMENTS: eceIP IIsi RECORD 0 Retain a copy with permit • NSPECTION FEE REQUIRED., Prior to reinspection, fee must be paid at 6300 Southcenter Blvd.; Suite 100. CaII to schedule reinspection, PERMIT NOv (206) 431 -3670 40LA Project Name Address City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Retain current inspection schedule Needs shift inspection Gary L. VanDusen, Mayor Control No. Permit No. Y_ ' "� \,) uLte v. Authorize y am. - Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre- Fire: Permits: FINALAPP.FRM Al.) ',. na ure rl Date .F.D Form •F:P::85 GYP BD Illmon4 aigib 11004 o•glilY 11� 411110•4 STEEL STUD BRACE @ 81- 0" O.C. TO ROOF PURL IN - ATTACH TO TOP OF WALL AND PURL IN 10' -0" .GATT INSULATION R -11 - VERIFY • W /ENERGY CAL CS. t 10 .1°41 TYP. 'OFF ICE•WALL FRAM I NG 'W/BATT INSULATION .7 p- 5/8" GYP EACH SIDE TYP I CAL PERIMETER .OFF 'I CE TO WAREHOUSE SCALE.: . I I/2 = I '--0" DATE 10 4 1 PROJECT NAME ADDRESS 10 CONTACT PERSON ARCHITECT OR ENGINEER PERMIT NUMBER tO122. PLAN CHECK NUMBER (206) 433 -1851 kik CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * *REVISION SUBMITTAL** 17 RECEIVED CITY OF TUKWILA OCT 8 1991 PERMIT CENTER PHONE 4 - 3'S .84 7 (If previously issued) TYPE OF REVISION: '' WuxLg�96 t rAgte } b1912 t& ' b , Of f°" bt2EAl I; Ize • � APPROVED p 1991 S v tE•U BUILDING, Ip VIbION SHEET NUMBER (S) hZ !� "Cloud" or..highlight al area of revisions and date revisions. SUBMITTED TO: kat Le. S david architect June 17, 1991 Revised - October 8, 1991 City of Tukwila Building Department 6200 Southcenter Blvd. Tukwila, Washington 98188 Re: Energy Code Compliance Calculations For: Lindal Cedar Homes 10q00 Martin Luther King Way South Tukwila, Washington Dear Sir, PIECEIVED CITY OF TUKWILA OCT 8 1991 PERMIT CENTER The Following are energy calculations per Chapter 't, Component PerFormance Approach, oF the Washington State Energy Code, 1986. In designing this space, the design parameters of climatic Zone 1, indoor design temperature shall be 70 deg. F. For heating and 78 deg. F. For cooling with indoor design relative humidity For heating shall not exceed 30 percent were used. Outdoor design temperatures shall be 2'l deg. F. in winter and in summer, 83 deg. F. dry bulb, 67 deg. F. wet bulb. Air quantities shall be per Table 3 -1, oFFice 15 cFm /person and conference rooms 25 cFm /person. These can be reduced by 33: For recirculating HVAC systems, all outside air. The building insulation shall maintain substantial contact to unexposed surFaces oF ceilings and walls and need not have a Flame- spread rating or smoke density (pg. 21, 2, exception B). Moisture control shall apply to walls but not ceilings as per pg. 22, 1, B, ii. Assumed is the ground cover and perimeter slab insulation are in place at oFFice only. Section 'iO4 was used For this space, Table 'i -3. All exterior window and door Frames and wall panels have been caulked and all doors will be weatherstripped. (206)433 -8997 0 12878 INTERURBAN AVENUE SOUTH 0 ' SEATTLE, WASHINGTON 98168 City of Tukwila June 17, 1991 - Revised 10/8/91 .Page 2 Lighting power budget For oFFice is 1.7 watts par square Footing with individual switching of rooms 'i00 s.F. or less and dual level switching For areas over '.00 a F. Building areas greater' than 200 s.F:., or. within 12' to an. outside window shall also have ' dual level switching. As calculations show, the building will be in compliance with the State:Energy -Code. Enclosure: Calculations , TD .K STATE OF WASkiNu1 Sincerel .Energy Code Calculations - Revised 10/8/91 Lindal Cedar Homes * Wall Type I (Interior) * Wall Type II (Conc.. Tilt -up Panel) * Wall Type III (Windows New) 'µ Wall Type 111a (Windows Existing) * Wall Type IV (Ceiling) * Doom Interior Wall CSustem I) Inside Air Film 5/8" Gyp. Bd. Batt Insulation Air Vapor Barrier 5/8 Gyp. Bd. Inside Air Film R Uw1 Exterior Wall (Sustem II) Outside,Air Film Conc.' 6 -1/2" (0.08 /in) Batt Insulation 5/8" Gyp. Bd. Inside Air Film Windows • (Sustem III) 1" Insulated Ceiling CSustem IV) Inside Air Film 3/'1 "•:Ceiling Tile` (2.78/in) Insulation Inside Air Film Door Gross Walls Exterior East 48' x 9.5' A 456 South- 62' x 9,5' - 589 U = 0.351 Interior West - 48' North--; 62' x 9.5' am '356 x 9.5'. '589 0.68 0.58 19.00 0.00 0.58 0.68 = 21.52 - 0.0'165 0.17 0,52 19.00 0.58 0.68 R ' 20.95 Uw2 m 0.048 New:Window Uwinter 0.31 Usummer 0.36 0.68 2.09 19.00 0.68 R m 22.'15 Uclg 0.'1'15 102'1 s.F. 659 s.F. 19'1 s.F. 171 s.F. 2976 s.E. '12 s,.F. 5066 s.F. Existing - Window 1.13 1.1 Gross Ceiling 62' x 48' = 2976 Windows New Existing East - 12'x 9.5' = 11± s.f. 12'x 8' - 21 = 75 s.F. South- 10'x 8' = 80 s.F. 12'x 8' = 96 s.f 194 s.f. 171 s.F. Door West 3'x 7' = 21 North- 3'x 7' = 21 Wallow = .25 x 2090 + .035 x 2926 5066 = 522.5 + 104.16 = 626.66 5066 5066 = 0.124 OR = 8.065) Uo= 0.0'i7(102't) +0.'18( 659)+ 0. 31(19' t)+ 1. 13(171) +0.0't5(2976) +0.351('42) 5066 48.128 + 31.63 + 60.14 + 193.23 + 133.92 + 14.74 5066 '181.788 5066 Uo =:0'.095 CR = 10.53) Uo is.leas than Uallow, system as designed is ok Plan Check #91 -257: Lindal Cedar Homes 10400 Martin Luther King Wy S THE FOLLOWING COMMENTS APPLY TO AND BECOME PART OF THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER (6 . 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4732). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (872 - 6363) . 4. All mechanical work shall be under separate permit through the City of Tukwila. 5. All permits, inspection records, . and approved plans shall be posted at the job site prior to the start of any construction. 6. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 7. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 8. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 9. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washignton State Energy Code (1989 Edition), and Washington State Regulations for Barrier Free Facility (1989 Edition). Lindal Cedar Page 2 10. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction.. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid "X" REQUIRED INSPECTIONS PHONE APPROVED INITIALS CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 7 Framing 431 -3670 8 Insulation 431 -3670 R 9 Suspended Ceiling 431 -3670 10 Wall Board Fastening 431 -3670 11 12 13 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 X 17 BUILDING FINAL 431-3670 CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: 10400 Martin Luther King Wy S BUILDILG PERMIT INSPECTION RECORD (Post with Building Permit In conspicuous place) SUITE NO : BUILDING (40-7Qa PERMIT NO. DATE ISSUED: PROJECT: Lindal Cedar Homes CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (INSPECTOR COMMENT SECTION ON REVERSE) INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied In place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be Installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. 09,14,90 PLAN REVIEW COMMEL Plan Check No. :q ` "'" 7. Project: y < No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. REQUIRED INSPECTIONS Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296 - 4722). y Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277- 7272). 2e All mechanical work shall be under separate permit through the City of Tukwila. X . - All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special Inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high- strength bolting to be special inspected (Sec. 306, UBC). Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced If over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 1 . Any exposed insulations backing material to have Flame Spread Rating of X 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given In the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). pt . All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special Inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. 1. Footings 2. Foundation 3. Slab /Slab Insulation 4. Shear Wall Nailing 5. Roof Sheathing Nailing 6. Masonry Chimney X 7. Framing 8. Insulation ? c; 9. Suspended Ceiling .( 10. Wall Board Fastening 11. 12. 13. X 14. Fire Final 15. Planning Final 16. Public Works Final 17. Building Final PLAN REVIEW COMMEL Plan Check No. :q ` "'" 7. Project: y < No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. REQUIRED INSPECTIONS Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296 - 4722). y Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277- 7272). 2e All mechanical work shall be under separate permit through the City of Tukwila. X . - All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special Inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high- strength bolting to be special inspected (Sec. 306, UBC). Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced If over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 1 . Any exposed insulations backing material to have Flame Spread Rating of X 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given In the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). pt . All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special Inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. Dear Sir: City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Fire Department Review Control #91 -257 (512) July Gary L. VanDusen, Mayor 1991 Re: Lindal Cedar Homes - 10400 Martin Luther King Jr. Way S . The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.1040 Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 10.402(a). Exit signs shall be installed at required exit . doorways and where otherwise necessary to clearly indicate the direction of egress. Signs shall be of a contrasting color with the surrounding area and shall have letters not less than six inches high with a minimum letter width of 3/4 ". (UBC 3314) (UFC 12.108) Exits shall be illuminated at any time the building is occupied. An emergency system shall automatically provide exit illumination upon failure of the main power supply. (UFC 12.107(a)(b)) 2. All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NEC 70) (UFC 85.101) All electrical wiring is to be inspected by the State Electrical Inspector, Washington, State Department of Labor & Industries. (NEC 70) 4 City Of Tukwila PRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Page number Gary L. VanDusen, Mayor A11 required occupancy separations,..`area separation walls, and.draft -stop partitions shall be maintained and shall bepr.operly repaired, restored or replaced when damaged, altered, breached,` penetrated, removed .. or improperly. installed. (UPC 10.401) . This review limited to speculative tenant space only special fire permits may be necessary depending orb 'detailed description of intended. use.. CITY OF TUKWLA Department of Community Development - Building Division Phone: (206) 431 -3670 PROJECT: Lk 1.1't-)e.L. ADDRESS: DATE: TYPE OF CONSTRUCTION 'nr--1..1 ST)g, LOCATION ON PROPERTY - r{et . e'),S BUILDING HEIGHT /# OF STORIES b �3L FLOOR AREA EXITING REQUIREMENTS DETAILED REQUIREMENTS OCCUPANCY TYPE OF CONSTRUCTION PART V, CHAPTER 23, U.B.C. W.S.E.C. CHAPTER 51-10, W.A.C. NOTES J.�Ly ( t ctL l PLAN REVIEW vi4 1 !: ex; c Proica 3 (*Pic* 22 t ms a D PLAN CHECK NUMBER 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 1 D 00 krkT N LUT !4 ti..S Y.5 a. .r OCCUPANCY GROUP W Alt, Itut1... t1,16 OCCUPANT LOAD PREPARED BY: di V DATE: 7- 1-11 LO. kehle arehitec June 17, 1991 City aF Tukwila Building Department 6200•Southcenter Blvd. Tukwila, Washington 98188 Re: Energy Code Compliance Calculations For: Lindal Cedar Homes 10'100 Martin Luther King Way South Tukwila, Washington Dear Sir, The Following are energy calculations per Chapter '1, Component PerFormance Approach, of the Washington State Energy Cade, 1986. In designing this space, the design parameters of climatic Zone 1, indoor design temperature shall be 70 deg. F. For heating and 78 deg. F. For cooling with indoor design relative humidity For heating shall not exceed 30 percent were used. Outdoor design temperatures shall be 2'1 deg. F. in winter and in summer, 83 deg. F. dry bulb, 67 deg. F. wet bulb. Air quantities shall be per Table 3 -1, office 15 cFm /person and conference rooms 25 cEm /person. These can be reduced by 33% For recirculating HVAC systems, all outside air. The building •insulation shall maintain substantial contact to unexposed surfaces of ceilings and walls and need not have a Flame- spread rating or smoke density Cpg. 21, 2, exception B). Moisture control shall apply to walls but not ceilings as per pg. 22, 1, B, ii. Assumed is the ground cover and perimeter slab insulation are in place at office only. Section L±0'i was used For this space, Table '1 -3. All exterior window and door Frames and wall panels have been caulked and all doors will be weatherstripped. RECEIVED \NILA Or O JUN 2 1991 pERw►vr cENY61 (206)433 -8997 0 12878 INTERURBAN AVENUE SOUTH -0 SEATTLE, WASHINGTON 98168 City of Tukwila June 17, 1991 Page 2 Lighting oFFice is 1. 7 watts per square footing with `individual switching -aF .rooms ' 400 s . F . or less and dual level switching For areas over L100 s:P, Building areas. greater than ,200 s.f or within 12'. to an outside ipindow shall also have dual level switching. As calculations show, the building will be. in compliance with tha State , Energg ;Code . Door U = 0.351 Energy Code Calculations Lindal Cedar Homes * Wall Type I (Interior) * Wall Type II (Conc. Tilt-up Panel) * Wall Type III (Windows) * Wail Type IV (Ceiling) * Door Interior Wall,(Sustem I) Inside Air Film 5/8" Gyp. Bd. Batt Insulation Air Vapor Barrier 5/8" Gyp. Bd. Inside Air Film R = 13.52 Uwl • 0.07L1 .Exterior WalL(Sustem II) OutsideAir Film 0.17 Conc.. 6-1/2" (0.08/1n) 0.52 Batt Insulation 13.00 5/8" Gyp. Bd. 0.58 Inside Air Film 0.68 R 14.95 Uw2 = 0.067 Windows '(Sustem III) . 'Insulated Uwinter 0,49 UsUmMer(1.58 Ceiling (Sustem IV) • . Inside Air 'Film- 0.68 3/4" Ceiling Tile 2.09 (2.78/in) Insulation . 11.00. Inside Air Film ' 0.68 R 14.45 . Uclg = .069 Gross Walls Exterior East - 48 x 9,5' 456 South- 48' x 9.5' Interior West: 48' x S.5'156 North x 7 456 0.68 0.58 11.00 0.00 O .58 O .68 870 s.F. 554 s.E. 358 s.E. 2304 s.F. 42 s.E. 4128 s.F. Windows East- 12'x 8'x 2' = 192 South -. 12 ' x 8' = 96 10'x 7' ° Door ,West 3 x 7' a 21 North- 3'x 7' = 21 0.07'-i(070) + 0.49(358) + 0.067(554) :+ 0.069(2304) + 0'.351 (L12) ''f128 64.38 + 175.42 2 + 37.12 + 158.98 +.1.47 4128 Uo ° 437.37 '1128 Uo = 0.106 (R =9.LH) Uallow .25 x 1824 + ..035 x 2304 4128 = 456 536.64 1+128. '4128 0..13 CR _ s less than ' Uallow, sustem as designed is'ok 3 Wri . 0 LEGAL DESCRIPTION: <A itleo 1244. • 650 . 91- N Sec." SS 2F, " rlG" f 3c� dst. FT. F�c!�T .jCa rpt.1!L .rill Jer 4.-512o FT r ft o — Mvotivd 00' 6Emew f t 7— IN=r-P. L. e That portion of the northwest quarter of the southeast quarter and the northeast quarter of the southwest quarter of Section 3, Township 23 North, Range 4 East, I.M.; King County, Washington, described as follows: Beginning at the intersection of the northline of said northwest quarter with the west margin of Empire Way South (said west margin being 60 feet from the monument line thereof); thence north 86 °58'28" west along the north line of said northwest quarter 650.94 feet; thence South 3 °02'32" west 249.89 feet to the north margin of the Boeing Access Road Interchange; thence north 63 °46'45" east along said north margin 52.03 feet to a point of curvature of a 325 foot radius curve to the right; thence along said margin and curve 635.7 feet to a point of tangency on the east margin of said Boeing access road; thence south 4 °06'30" east along said margin 134.84 feet; thence north 85 °53'30" east along said margin 64.41 feet; thence north 34 °02'42" east 133.42 feet to said west margin of Empire Way south; thence north 0 °02'44" east along said west margin 480.68 feet to the point of beginning. SUBJECT TO: an easement for ingress . egress and utilities, being 50 feet in width, the centerline of which is described as follows: Commencing at the northwest corner of the above described parcel; thence south 3 °01'32" west 221.24 feet to the true point of beginning of said centerline; thence north 63 °46'45" east 38.03 feet to the point of curvature of a 350 foot radius curve to the right; thence along said curve 160.45 feet to a point of tangency; thence south 89 °57'16" east 240.99 feet to a point of curvature of a 400 foot radius curve to the left; thence along said curve 104.47 feet to a point of reverse curvature with a 400 foot radius to the right; thence along said curve 104.17 feet to a point of tangency; thence south 89 °57'16" east 25.00 feet to said west margin of Empire Way South and the terminus of said centerline. 1 ve-euip di o b'd o/ A 1-ri 0iew, - t4)- IeM 2 litiu4 Net •Oa a ex.! < t._IG r5 0 a 2 1°11 9 FT. _1 64•* N . 8c, b' 3°' E. IilIiIIII „ALL, 1 1- _e.e F'4RKIu.le - �ardhL 4, exivrea JJiLLLL • ---3' Mgoi/ J -r 1 5 12 T M i .,...: 1 1 1 � � S BENEFIT z ch ` .S tr D o \`\ s to , . ST 3 w . iTS RORi T S z a 4 P116RI ,r `r gY u w • S BOEI .. 41AR1 011U _ ,, 1113TH ST HE ' D RSO s1 TMPI 1 • RAINI R 1261 r. I' I �• II I L L II I I I I II I`Z V II I 'I ' V � I 11 1 I1I1 � 11 'II 1 1 1 I111 1 '11 I I g L• I No.18 �° _ • ; . w;t ® Indicates WDOE reeietered USTe within approximate 2000 feet mrcemssoe •-• 4 ►• •4111 AIL. J/1 HS 1 2 �. ,'3 � 1,4 ST � A +i�HC roH ; 4414 610 2q » o Peretterfrt Ncitri Hp 001 etc.. LoA• BUILDING AND SITE STATISTICS ZONING: BUILDING CODE: UBC 88 BUILDING TYPE: V -N SPRINKLERED OR III -N SPRINKLE.'RE!) OCCUPANCY GROUP: B2 OFFICE AND WAREHOUSE 4 BUILDING "B" TOTAL SQUARE FOOTAGE: 29,040 AREA OF TENANT (LINDAI• CEDAR HOMES) 9,024 s.f AREA OF REfviODEL : 2, q 3 ' 1 EXISTING OFFICE TO BE PEMOVED: 328 s.f. PARKING FOR NEW OFFICE: AREA @ 2.5/1000 = 5 STALLS* *RE STRIPE SOUTII SIDE OF BUILDING FOR 43' STALLS AND REMOVE 2 STALLS � Ifl tic crf e - (D,� 4 to g c Ib1L 4: ttn ll 1. i`,yto 11 , I understand that the Plan Check approvals era subject to errors and omissions ano approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con - tracta c of approved plans acknowledged. S VPAta �1.� N‘\‘‘, ; Yt 1 Ciau 1-616(9 g j��INv CANASION IU7I I�G1 .� RE.VI tc.e. 4 RIMED CITY OF TUKWILA OCT 8 1991 pmmilmCrff R oti 9 Lt lzk 4 5> 8 gm tu BC tV •• LU CL w w 2• x 11 et g e3 d W al 0 ima NJ CI 4 ,�. A -1 0-) > O co co rn 4 T ct) = to ch c UJ v Z J c ~ N N CA 14Cr 43) >M W 1 1 ght Z a CO CO 1 1 • a 11 - 11 1 1 5 (A 1 pp r-Leeit al c.61. Rue!, nw 4 •?1.? A.! - - IWJLI11L 'u ''q 4-- GNI ' 1 '::•,:- iii - frt p(orrt b rd • e76.4 ‘1 1(4 vntl, 1 , 6urLe1e-, „r1 4 /6 -r1' II! • •• , •••••••±1E , 00 il Jam . ts 0 0E4:rep or 411 ■••• • 41) 0 Aolia WAL-L? -ro Oittftept, 4rtia.4 101-214 co- Il veizi 7 t, pi i t i k Lop A 111611Litlalr 1Y" Zxt F:? flj-1 r Fr) ' AU- 4-1,6. E 10U;h11-1 r141212 WOLL "rt7 FIO‘mr R:›1 I.M1s4 P exi.vr PAI■l11- Rembo4 • - 44 - 4117 , I !...JALL5.? re, Ite. P - 4410 6511.41c4 • A • a a • • AMMI:FINAIPMINIFIVIRIPPIPMPlergertrieirt - - 4 2 fri FLITutiP. • toi `7100 00X., VVt?"4 ii,61tecti OtArr, 6rud miipe;c4otti9kt -69 POPli HYAC • 0 ... 4 5 11 $tevEzz* 2 FLIF5P *E. 1.101*E)- V't gzasszf 1.1E1-1 /4 tt.)1D 1 '4 1 / 4 14- kJ/ 60111JD 13,41'r WY - 1> P ef l kd • Z4 FRAME PPM Feirri IPLP yi co f,k. AVG' 1 I - I vw h1 PiorPHh _j - 11411U ReCt tizti Whirl/VA jj . 2] 3 4 1 51 6] No.I8 _ tieit • illumimer7 154 M44 -1*.tr• (1. 1W-2-11.4 l4b kl4r auwa SV firl 1 Ili iirii 111 1 tit h 144 )(11'11M% ortsic.e. V116.1614 1We-4.E P11.1.1 6 • 6iNE110141 wto W441144 L ' EMMIN.M. f4 tompterm 6 et- we)Fier 0 110 &0•WER-44- ALL. C-4A,V011214,1riONJ 400Ft%r-4•A 71-4e, nee L . 15. G, E7 Mlia•J cori t,lerrn_41,,cr ti„t-ie.- 14& 1-J L-4 L4. 404J211100s, 11_1E, f :54 e.t-E , VAL.Tk9t■1 4 -47n-IE.. a"1.1 —144.1— 15*. tae."..re,Ni. ,e- P r ALL I J:45 e-vi1/4n ft,ft-iTy• ecm plrr 1,1 ITO e. Nisi...rr - 4.5 714 Icy raptl v " o os-r. RS211:1.1'5151 (-Ty re Tc-IE- 1.4, Tc=14 " . E weqc-, e&I--1 P44 L-1.1M k-,11-ro IzEd . 44-)-- 14217 Plger-r (.. 14 T1-I 491 rger--"m epe., p., AA Pv-v• AT A - f_ithz. L':,1--14 a ) • 5cHELLE Hem ouotfrict - NFictiti, err WPM. 4.. AL-L. r•PAtsl a lugq i N4 61 4/k 2.- te*-1 PE. a c• , T ,. rile-0.4..1.11cL toii-tubara ror-itafl (ft;612-tfte Ftamil) 4, kw Hee.4-14.;4 !GAL. Te7 e=e- 1 ( pez 1.1 , c-. c-e1.1Tr-,44.--yorz - r r/e.e-m 401/4-1 dl!zrrAlt e Arr120-/A.L. 4 AL-1.- ArrganglATe; 51-11 L-211•461 ptyee, 1.kt-rtiwortya. tXgrowt1 (0 i:ttioirt) a- • _ 11-IVIAJJ-EAP e- c.--.1 A:friac9r4A17......iitarli `IelKI Arn/44_ . 5Flt 101L5WP 1 , rxlef111.Y.:, 5FPNI.ILEP) IJ 1 SeNKJKLE1 POP, 1.1E14 AY ce 110. IL ANC cotuvrhucriow Mge 1 4 c-t-ty MKQUIrel-tek.173, 4911124ett* 9replai (z* Mt) 5 G S.C. 1,,JOOD r: rFiAmE, 1 1 4 113, garri siLELLER PP, 1■/#4-"Y PJAL.A., 4517, P,' 3 ` 6.-.14--100C, 12:i%12. 4 reteiti Ivz. 02. NI Ifr (kik tVoLl, 9 io2. tor (61iswoLe) 3ox(p Vox' X012 riZt>it, 1Vz pt, 607 miocelb, teak VatiKorbp co 561 /Ale 10 06 -our.* gochku, NyowtS PLact) V11.11 EA- ( ps41.1 6Y1P. BP, Axle -(11.M %oleo* eoct, WA) ceiLuotPA‘iarric cm , t1-470 Stud 41'c .61111446 *11-vecrt Vi.aba \et earmea • . Itepe s• 60. polirt *it eE1Llab I 14em Slit4 &loci &Nu Mice 1 12efridve.13Mliki r1coell-k4 bilbeN4 O Iker iktets* boeMo Grp, ep 1Jew1atitt ,x4e (bv RN ea ) keiuuc is4iiiu 144 4 kw fbittt 4. Ham 114 4 14vi poor •xt 0014 pimAtoioatklit, wwe 4 r1 16 ‘e Pew Ablyvt (lbetodituerbvti)witeleNist (4t ileaCtmet),Aloviai - Riot lxle ColUtici :-Iev 04' AYs.kourftv„‘Nutici NECEIVID CITY OF TUKWILA OCT 8 1991 PERMITGENTER N- O) 0) co co T V At ICKIELARD iUDBOIIT & ASSOCIATES, INC. CONSULTING ENGINEERS 1605 12TH AVENUE • SUITE 18 SEATTLE. WASHINGTON 98122 206-324-6160 I.0 SHEET K:6 CALCULATED BY CHECKED BY SCALE NEW operiI Nt., Cr -NtM2 1 N pr% Nf'r�t 51 or N f o Ac/co. GOIJ G , 130 El. --� CUT OW 0M1,1 /)JG Iu IN) t FDFi kJlNDok* o yb ' ' r i z y.H GLAf� O • -IJC9 JOB LINDAL C4nAR. 14OI1IES T' DATE c, 1 4'gl DATE C..I LI I\-1C= G PA 1 AL SOU -. E SALE. 4 - ! -J NOUr'•P ° ' Jl Lffiat,'4 \y!r coy UI4 7i 3g 3g )e 0(. °I 5/8 "' Fr AP. b0I.T f�ti1lP.czij T.S . '/2X3' X 1/4 3'2 ,c vz.te-6 1 r Jo BLOCK 0 GRID FOAM TAPE @ WALL 2x6 CEILING JOISTS 5 /8' G'YP pf) . • f/ /-g1ii'b O1Jrok) 5 116trle- FAtJo &Po �o Q!Ho f t 5� P$9 -r ( G3LazII4 C' 2 I /2' RUBBER BASE @ CARPET 'DST .G T T, P� Per , A. 22" WIDE SOUND BATTS EA. SIDE WALL SOJND WALL �o ■uuut.ul 11111/1"..111111111.11R11111111111, (" SECT I ON SCALE: 1 I/2" = 1' -0' r - FOR WALLS GREATER THAN 8'- O' IN WIDTH WITHOUT AN INTERSECTING WALL, PROVIDE 12go. WIRES SPLAYED @ 4$` TO AN ) EYE SCREW @ Ooor \I VI ,AND TOP OF WALL 3 4 0 I/2 3/ 5/8" GYP. BD. (TYPE X' @ FIRE RATED WALLS.) ACOUSTICAL BLANKET @ SOUND WALL. CAULK GYP. BD. TO FLOOR @ ALL SOUND AND INSUL. WALLS SECTION ----- E3A'TT INSULATION - R-11 -- VERIFY W /ENERGY CALCS TYP . OFFICE WALL FRAMING W /I3ATT INSULATION 04 10" % `: /8'' GYP. BD, r C4CHH SIDE= ■ )SCALE; TYPICAL PERIMETER OFF ICE TO WAREHOUSE I I/2' = 1'-0 r ill' i)I Iill1"IIlI 1 2 i�l►��i�lr�lii�l�r�i�li� -�Gb!de; , / ; ltd ® PAPYIAL r L Io D I4lr'c U111 1itilUti 64, tb ►-'1U�'GEI I =X� r P `Zy? izeoza 1II1W1 iI+1 gait iw urltal W4It'r rI t'Illr' ktate 70.\Aritri Or Cal fli►rtto 641P' *40 I*1I461-4.r'2. 1 4 'h lot P,fai k - %eur U4ttt pqtiet iLiliti5lilil1lil11i11 No.18 hami I t 1 - p u SC/ = AFERy !ML -/!Z thl OEW 8 - (.O' FF IJ��r • kEMov ex' k nErAiv..5 IrPriC Is/ T. S I G off DOH tar r 1V2 x 2006. tai \vl haE\• G lb" e, IBC IV 'AO R6N6i q , 1 6i ? ; Nct a -it NOTE. I USE IN SEISMIC AREA AS RECD' D BY CODE 2. SUPPORTING WIRES TO BE #9 GA. C O/C CONNECTED TO BOTTOM CHORD OF TRUSS W/ I I/ EYE_ SCREWS. EMBED I' MIN. 8'- 0' TO !e . -- O,. A.F.F SEISMIC NC SCALE L Mie L EC,T - E I L PJC, PLAK1 6F310 t 9 I _ s " i� ul,t al -Dr c oui`lc4 \' 112.112- INSTALL #I2 GA.VERTICAL W I R E CONNECTED TO M A I N RUNNEF & TO STRUCTURE ABOVE. INSTALL A SECTION OF I 1/2' x 2.0 GA. STUDS W /VERT I CAI_ WIRE RUNNING THRU CENTER OF STUDS STUDS TO RUN FROM TOP OF TEE TO BOTTOM OF STRUCTURE ABOVE. WRAP END Or VERTICAL WIRE AROUND STUDS BOTTOM.. FASTEN STUDS TOGETHER W SCREWS AT 18" 0/C (SEE DTL / ) CROSS RUNNER INSTALL #I2 GA. WIRE CROSS BRACING i N EA. PLANE OF MAIN RUNNER 4 S @ 12' - -0' O/C @ 45 ANGLE !H BOTH D I R E C T I O N S W/ TOE FIRST POINT WITHIN AS r 6' -0' FROM EA. WALL BRACING MAIN RUNNEI: • RECNIVED CITY OF TUKWIlA OCT 8 1891 PERMIT ceNtiT R N fi LI; ( 4112 !ii p law 0 .1 4 F— N 4 0 o w X J p cc d 2 O 3