Loading...
HomeMy WebLinkAboutPermit 6759 - Mancini / Groesbeck - Tenant ImprovementPermit 6759 - Mancini / Groesbeck s ;E TYP •F • .. UB EDI I•N (year) 1988 SETBACKS: N- S- E- W- FIRE PROTECTION: ❑Sprinklers ® Detectors ❑ N/A UTILITY PERMITS REQUIRED? ❑Yes ©No rouh p g Worlcs) ZONING: BAR /LAND USE CONDITIONS? ❑ Yes ❑X No CONDITIONS (other than those noted on or attached to permit/plans) A _ CITY OF TUKWILA Dept. of Community Development- Building 6300 Southcenter Boulevard, Tukwila WA (206) 431 -3670 BUILDING / n PERMIT NO. �D � 5 DATE ISSUED: SITE ADDRESS PROJECT NAME/TENANT Mancini Groesbeck ASSESSOR ACCOUNT # 336590 -1390 TYPE OF ❑ New Building Addition Tenant Improvement (commercial) Li Demolition (building) U Grading/Fill WORK: ❑ Rack Storage ❑ Reroof ❑ Remodel (residential) ❑ Other: DESCRIBE WORK TO BE DONE: Remove existing door and non - structural partition on second floor and add additional walls on first floor. PR•P • • ER ADDRESS CONTRACTOR ADDRESS ARCHITECT ADDRESS tb`TA . I CERTIFICATE OF (OCCUPANCY NO. 14501 Interurban Av Six Star C -i Division 98188 14501 Interurban Avenue South, Tukwila, WA Constructive Energy, Inc. 3235 California Ave. S.W. Seattle WA WA. ST. CONTRACTOR'S LICENSE # CONSTE I 110JJ Todd Lawson 71 Columbia 11302}3, Seattle, WA This p shall b ecome null and void if the work n co nn7ence� issuance, or if the.:work !s suspended or ab andone d fora period of AN A BUILDIf' a PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) BUILD.ING:S.URCHARGE '< 450 DESCRIPTION :::;'': AMOUNT BUILDING PERMIT'FEE PL'AN'CHEC.K FEE .:11'7 i:00 ::0672 76':00 Q672. 7 22 -91: w22 »91':. 4THER TOTAL.. PLAN CHECK NO.: 91 -305 SUITE # DATE ISSUED: VALUE OF CONSTRUCTION - $ 9,700.00 PH •N PHONE EXP. DATE 01 -10 -92 PHONE CODE: COMPLIANCE USE,- FLOOR:'e` .y •u• SQUARE OCC. SQUARE OCC. FEET LOAD FEET LOAD SQUARE OCC. SQUARE OCC. SQUARE OCC. TOTAL TOTAL FEET LOAD FEET LOAD FEET LOAD SQUARE FEET OCC. LOAD APPROVED FOR ISSUANCE BY: • BUILDING DATE: OFFICIAL DATE: IPJA I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presu e o give authority to violate or cancel the provisions of any other state or local laws regulating constructiorlor th� -perfo `ance of work. I am authorized to sign for and obtai this building permit. PRINT NAME: ,, SIGNATURE: COMPANY: vvrthfn 1 t 80 days aay rom t �e. 248 -1135 ZIP 98168 932 -2277 ZIP 98116 382 -9585 ZIP 98104 rom i3e: ate ast ins ectio PERMIT NO. (0 ,—' 5'9 CONTACTED Lek*-- �+ DATE READY q _ 4 _ ' DATE NOTIFIED .. 1 6_ ( ) (init.) ___ 49.65 PERMIT EXPIRES _ 2nd NOTIFICATION 3RD NOTIFICATION BY: (snit.) BY: (init.) AMOUNT OWING BUILDING( 'HERMIT APPLICATION TRACKING PLAN CHECK NUMBER q t3oS INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE OCC. FEET LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET DEPARTMENTAL REVIEW "X" in box Indicates which departments need to review the project. 40 ATM J BUILDING - initial review .bIFIRE 4 R O PLANNING O PUBLIC WORKS O OTHER BUILDING - final review /1 E REVIEW COMPLETED PROJECT NAME SITE ADDRESS SUITE NO. 6 12 d I R (ROUTED INIT: INIT: INIT: INIT: IN T: v S CONSULTANT: Date Sent - Date Approved - c FIRE PROTECTION: • S • rinklers FIRE DEPT. LETTER DATED: 9- t , INSPECTOR: ZONING: REFERENCE FILE NOS.: MINIMUM SETBACKS: N- S- UTILITY PERMITS REQUIRED? Yes PUBLIC WORKS LETTER DATED: TYPE OF CONSTRUCTION: BAR/LAND USE CONDITIONS? UBC EDITION (year): 19 6 6S No SA TE ADDRESS SUITE `` # t501 • �: . i. ' l\ . V �JO . ,VALUE OF CONSTRUCTION - $ At 97D0 6 U ! PROJECT NAM ENANT GINI 6f0e5$C-Ck 0 U- � vc6a1 SSESSOR ACCOUNT # I39O commercial U Demolition (building) 0 Other: TYPE OF 0 ew Building U Addition Tenant Improvement WORK: 0 Rack Storage 0 Reroof 0 Rem del (residential) DESCRIBE WORK TO BE DONE: DN Mu. St ca gab' re Pi r�-i 446 ✓� 5 - f 4 &'/ t. - � ' loo is arc.. spiv. dd A.cki. ilia 14 -C t.v4I f 1 1.4)4's h' r cK1 hb ^ - Sfev /Vol/ v^r -&nr Hey A � .., r e rf 1�y 72,,e. X B UILDING USE (office, warehouse, etc - 1 ° "" 41'1 M VP/ Or FvGE. NATURE OF BUSINESS: r 5416 s requirements may need to be met. Please explain: WILL THERE BE A CHANGE IN USE? ,,No 0 Yes If Yes, new building SQUARE FOOTAGE - Building: { 1 a ( ,Cenant Space: 1 I (1:1 I(o Area of Construction: `Moo WI L THERE BE STORAGE OR USE 4 FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? No 0 Yes IF YES, EXPLAIN: PROPERTY OWNEf PHONE 2 ADDRESS 56 i i re 0 ie 54 & r Av. . 56 rtiA,,L� PHONE 761 ... CONTRACT -r- . TiS D 0 8�' 'TIC t2Nll/V ADDRESS t i ZIP --- WA. ST. CONTRACTOR'S LICENSE # ii, EXP. DATE -- , S� l�f`e H E �S1GI�1C . �dt� � L PHONE mg .75gs rAD 7 csuvi'Ita/tt +Al2z _43rze k zIP6.4j9 CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 DESCRIPTION r+.r rK.czc.2:�f:Aa�.sw. (PLAN CHECK NUMBER '.HEREBY.CERTIFYTHAT I HAVE:READ EXAMiNED' <ml S` APPLICATION;AND;;KN BE :TRUE AND :CORRECT, :AND .I `AM AUTHORIZED ;TO APPLY :.FOR THIS: <PERMiT .: SIGNATURE / OR AUTHORIZED PRINT NAME -- t, j . L hut, 1S01\ AGENT ADDRESS GOLUkt ,' / OZ S SG1� _ CONTACT PERSON T b , DISCO 1∎ BUILDING OWNER R1 305 BUILDIN PERMIT APPLICATION BUILDING PERMIT FEE PLAN CHECK FEE BUILDING SURCHARGE DATE APPLICATION ACCEPTED 1-&a-qt DATE APPLICATION EXPIRES AMOUNT: WI. RCPT: •# t -aa -q DATE E DATE 7 • 18- 91 PHONE 502. 7.5gs CITY/ZIP eof 3 PHONE 5 gg 15 APPLICATION SUBMITTAL in order to ensure that your application is accepted for p:an review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If ycu have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. :U1W91 COMMERCIAL— NEW COMMERCIAL BUILDINGS/ADDITIONS F .- I : Completed building permit application (one for each structure) : . :• .•-: : „ 'Assessor Account, Number • : • • • Two sets (2) of the following: • n i Specifications . . Structural calculations stamped by a Washington State licensed . „: • :, .• Soils report stamped by u Washington State licensed engineer Topographical survey Energy calculations stamped by a Washington State licensed . • : enginear or architect . ' • • . • ' : • Legal description . • . . . • . •• . Working drawings, stamped by a Washington State licensed : ----I architect, which include; . : • • Site plan :. . • :. • •. :* : ' • Architectural drawings • • Structural drawings • .• • • : • Mechanical drawings . • ••• • CiVil 1 I . Completed utility permit application (one for entire project) Six (6) sets of civil drawings .• • NOTE See utility permit application and checklist for specific utility submittal requirements. . : RACK STORAGE :,•'.'::'„ - 1,•:.:: :.:; ••• • .-.. . ,:::.:.., ....... :•.: . : ..,,..„,.... .., : ..... , . Completed building • : pqrmit ..epplic4!I09 ... , . . . . . , . . ,:.. .. . .. , .,.. . . . . . . . . . . . . .. . . :AsSeSSor Ac.count•Number ::::: :',:::,: • :-..•••••:::. Two (2) Sets of plans which ihalude: 1 : Building floOrl.:plari:showing: ' - h - . raci's will be located .... . . . ,. . ,,., ; - :..:'....•:Entire:spacP Y' 9,r..9 ra • ••• ::: • . . . . . . . , . : : ' : ::'• Dimensforis ot all ali10 . :,.•,,.. • : : ....,..,,,,.: . .. • • " • . . - . . • • " ' - . ' :::.:,...,.... ' : ---: TariantFaCie floor plan showing rack s)rage if layout, islas :::: and ,.•:. . . NOTE Include dimensions of racks (height, width and length) aisles and exit ways on : plart''.: '' •••,,•:::•: 1 : • ''. : :: ..... :. ,...:.... :. ,.,:.., : . ::., : • .::. . •::.. • . ....:: ',:.... . „ , ., ... : ,• . , . .. . . , . : , . Structural calculations stamped by aWashington State licensed ., . engineel (rack storage 6'.and Over) ' ::::::..... .:::::.,::: '::::::,,::',".:',.:•::::::::::::::::::: :.::,' RESIDENTIAL " SUBMITTAL CHECKLIST MMERCIAL TENANT IMPROVEMENTS I Completud building permit application (one for each structure or tenant) wo ••• . •• ••• ...• • • • Site plan • Location of tenant space • E • Landscape plan (if applicable, i e, change of use Overall building plan • tJso of adjacent (common wall) tenant ................................................................ • : Floor plan of proposed tenant space .. . . • Tenant space plan with use of each room labelled • Exi doors ogress patterns New walls, existing •-• • • Wall, !" and wails to be demolished :••••••"::::••••• • •,. . ..... • • . • • ••,. • • •••••':•••".".:•••••:Cross sectIo,.,.s,..aWingli,I.:construction . flooean,r ''::•••••• •:: hington'. ,tattf,,1 engineer may be,•required.ifsfructuraiWork:iato: e. done (2 sets) NOTE If any utility work is fe submit separate utility permit application And plans .. .... . •--- . REROOF. •• • Completed building permit application iJaiTatlye'Cla:ptr.161.fig..e)4tingroaf - material being installed . .. . ietter:fa prior to.'final.insPeCtiotndaign off of the permit . ....................................................................... ANTENNA/SATELLITE DISHES . . .. . . . .. . . - " Completed building permit application Assessor Account Number Two (2) sets of plans, which Include Site PJan (showing building and location of antenna/satellite dis Detalls:antennWst4eIlIte.illsh,:and.ajcloci.:01saaCIAen Structural calculations stamped by a Washington State license engineer: ritay: be required •■••■•••• [ Completed building permit application (one'or each structure . . . ri Two (2) sets of working drawings which include Site "plan • Foundation piun Floor plan Roof plan ................................................................... • • Building cross section • .•::: • • • • Structural raming plans NOTE II any utility work Is to be done p application.•••••••: and plans must be submitted REROOFS Completed building permit application Assessor Account NumberH.H:.::*: , . . . .. . .. ‘..,, Assessor •Account • ro ect: �h5 ; ¢ 4"."6444.7 ype o nspect o • -sy� / A dress: =te = e•: U--IR-- V Can Sp a nstru ons: * fah[ Reln Si'rru -r Date Want AP _ ._ (dub p.m. Requester: c Phone No,: � �'� 7 7g ' x�v...;,'. tw:. t n ..' , ; .y:� ' . 2' „ ' . �y"� . "Y'ar CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: nspector: Receipt No.: 1T INSPECTION RECORD Retain a copy with permit r PERMIT N0. (206) 431 -3670 ❑ Corrections required prior to approval: Co— El $30.00 REINSFECTION.FEE REQUIRED: Prior to reinspection, fee must be paid at 6300 Southcenter Blvd.,.Sutte 100., Call to schedule reinspeotion. Date: PROJECT: M lAil AMMIll PERMIT NO. i SITE ADDRESS: i 1 : VPIALMMIFIMIN DATE CALLED: b —/1 ' TYPE OF INSPECTION: ' . DATE WANTED: /v'' /5 --'7 / 8 ` m , PECIAL INSTRUCTIONS: / / , A i �+ 0 /!J. REQUESTER: 1.i1.•/. 10-64 I , �1�.� 1 .' + ._'.l PHONE NO.:. r - 2 7 INSPECTION RES LTS /COMMENTS: k !L . !W - i -.� : ,.j t _ - INSPECTOR: IP' DATE: / C) "(S -G CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 t �+ INSPECTION RECORD 6300 Southcenter Boulevard -- #100 Tukwila Washington 98188 CITY OF TUKWILA Building Division 8200 Southcentor Blvd. Tukwila, WA 98188 433 =1845: Permit No: 6 Date /o / .S � Job Address C� — 0 / . ?:. re)1.�.; ir..� A� J AAA. CORRECTION NOTICE The following items are found to be in violation of Ordinance t, — and shall be corrected. Signed ) ! ' 1 " .- r'tA Q i 1 ; ! "J E - y s -/ d1 n/ . r ( t 4- s r.S C A Psi . - 9 IA/ 14 7 1... (.2 1 0 ,` .te., Ak.3.. l = "71y ! A t / fv 5 (2 N C. I 't o '1J . ' E. L f - k_ ) , A -'S r �, t' # 7 r r.; i'r r R r .h:41... /to (3-o v r Building Official /Inspector o c. �.., . n1. Vh ' OA- : OLL.A4 ‘••whaPLA quo v :. o 1-1-:4-44 3 coo lu.�- i.� =°'r- o-� 'i1- S-►� -. aJl s of-f w-oti J2 G PROJECT: A/ et ./,,9 c- ii-? i �'J<",c .he_e PERMIT NO. ( ?S DATE CALLED: 4. -- _ - SITE ADDRESS: L/. 9 / , . ,,., ' , ,-., TYPE OF INSPECTION: - . jam,_ ,„_ DATE WANTED: 0 ...- 6 - - - 4 4 44 - REQUESTER: ca SPECIAL INSTRUCTIONS: 2 , 4 ..' 70 az- 5 P (--?,e-t/l-- PHONE NO.: �" 2 INSPECTION RESULTS /COMMENTS: / „_ . _ . _ ∎ - AO ._. �, � DATE: 9' - / /o-- 9/ INSPECTOR: /( . _ '/_, .. _.r2,, CITY OF TUKWIL A Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTION. RECORD 6300 Southoenter Boulevard — #100 Tukwila Washington 98188 J. Project Name Address Needs shift inspection n4.;:+ ��yu. rxi+? �@ 'rki.f�n.;c:;�.�'="�r.�+'�:J�'W �:µ .,. , ::�Htt7� ~ �4!w`t.4 ..,•• :.a'.�;K:�r S�' S" +� =; 4 .+ % ri.24 X�o: �-'.�t:',n .' < FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Gary L VanDusen, Mayor.. TUKWILA FIRE DEPARTMENT FILIAL APPROVAL FORM X Retain current inspection schedule Sprinklers: Fire Alarm: Hood & Duct : 'gyp Halon: A/ Monitor: Pre -Fire: Permits: FINALAPP.FRM Approved without correction notice \' Approved with correction notice issued Control No. Permit No. -- uite DATE PROJECT NAME 6. k y a rn o Y V ( w c , 4. Lea re00513Cc/AC) 'Piot 13'o< 9 6o9 6t ,/ 5 r PHONE d P: 7 S ADDRESS CONTACT PERSON CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * * REVISION SUBMITTAL * * RECEIVED CITY op TI IKWILA SEP 2 7 1991 PERMIT CENTER ARCHITECT OR ENGINEER PERMIT NUMBER 67 59 (If previously issued) PLAN CHECK NUMBER 1 ""° „?t: TYPE OF REVISION: k4& itit& 4,4 P l7I QV r 1 I1 I Cos% s Q ke v i CJ . ' - ! -'- el Q. " 1-1 eg'vE Ip L tie- J ..c VV1 i 411 i eN *ft 5e c IreiS ��- pre W; oti g #5 A/o / / / r /,, ' SHEET NUMBER(S) • , � '� +�' i "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED QE UCSEO sroPE a� arc &AIWA - caa s cuw,pir,.nrE:a Ar• De.eerur _ u.¢Jre. CITY OF TUKWILA 6200 SOUTIICENTER BOULEVARD, TUKWILA, WASHINGTON 98188 Plan Check #91 -305: Mancini /Groesbeck 14501 Interurban Av S PIIONE # (206) 433.1800 THE FOLLOWING COMMENTS APPLY TO AND BECOME PART 0 1 THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER 0 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (872- 6363). 3. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 4. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 5. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 6. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 7. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1991 Edition), and Washington State Regulations for Barrier Free Facility (1989 Edition). 8. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any-of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. Gary L. VanDnscn, Mayor "X" REQUIRED INSPECTIONS PHONE APPROVED INITIALS CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 1 6 Masonry Chimney 431 -3670 . x 7 Framing 431 -3670 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 x 10 Wall Board Fastening 431 -3670 11 12 13 H 14 FIRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 X 17 BUILDING FINAL 431 -3670 CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 S ITE ADDRESS: 14501 Interurban Av S BUILDIG PERMIT INSPECTION RECORD (Post with Building Permit in conspicuous place) BUILDING PERMIT NO. DATE ISSUED: SUITE NO.: PROJECT: Mancini /Groesbeck CALL FOR INSPECTIONS AT LEAST 24 HOURS iN ADVANCE* (INSPECTOR COMMENT SECTION ON REVER INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is In place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. 09/14190 Plan Check No.: 9 I ` US' Project: REQUIRED INSPECTIONS PLAN REVIEW COMMEI S No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). C;) Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277- 7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. C) f All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). All high- strength bolting to be special inspected (Sec. 306, UBC). Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23, All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. 1. Footings 2. Foundation 3. Slab /Slab Insulation 4. Shear Wall Nailing 5. Roof Sheathing Nailing 6. Masonry Chimney 7. Framing 8. Insulation 9. Suspended Ceiling X 10. Wall Board Fastening 11. 12. 13. X 14. Fire Final 15. Planning Final 16. Public Works Final X 17. Building Final Plan Check No.: 9 I ` US' Project: REQUIRED INSPECTIONS PLAN REVIEW COMMEI S No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). C;) Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277- 7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. C) f All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). All high- strength bolting to be special inspected (Sec. 306, UBC). Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23, All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. Plan Check No.: Project: REQUIRED INSPECTIONS PL.All REVIEW COMMEK IS 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277- 7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. 5. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high- strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 11. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). 17. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. 24. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. 1. Footings 2. Foundation 3. Slab /Slab Insulation 4. Shear Wall Nailing 5. Roof Sheathing Nailing 6. Masonry Chimney 7. Framing 8. Insulation 9. Suspended Ceiling 10. Wall Board Fastening 11. 12. 13. 14. Fire Final 15. Planning Final 16. Public Works Final 17. Building Final Plan Check No.: Project: REQUIRED INSPECTIONS PL.All REVIEW COMMEK IS 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277- 7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. 5. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high- strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 11. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). 17. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. 24. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. ...tee.. 40 A City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Fire Department Review Control #91 -305 (512) Gary L. VanDusen, Mayor August 13, 1991 Re: Mancini /Groesbeck - 14501 Interurban Avenue South Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 3302(d)) Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 10.402(a). Exit signs shall be installed at required exit doorways and where otherwise necessary to clearly indicate the direction of egress. Signs shall be of a contrasting color with the surrounding area and shall have letters not less than six inches high with a minimum letter width of 3/4 ". (UBC 3314) (UFC 12.108) Exits shall be illuminated at any time the building is occupied. An emergency system shall automatically provide exit illumination upon failure of the main power supply. (UFO 12.107(a)(b)) 2. All fire alarm systems, fire hydrant systems, standpipe systems, sprinkler systems and other fire- protection systems shall meet the approval of the Fire Department as to installation and location. Plans and specifications shall be submitted to the Fire Department for review and approval prior to their construction. (UFC 10.301(f)) *"' City tr Tukwila SI FIRE DEPARTMENT 0 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 2 Local UL Central Station supervision is required. (City Ordinance #1327) Call the Tukwila Fire Department at 575 -4404 for approval of any system shut down. Have job site address, name, and the Tukwila Fire Department Job Number available to confirm shut down approval. (UFC 10.301) 3. All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NEC 70) (UFC .85.101) All electrical wiring is to be inspected by the State Electrical Inspector, Washington State Department of Labor & Industries. (NEC 70) 4. All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd Gary L. VanDusen, Mayor PLAN REVIEW MEMO: August 12, 1991 TO: PLAN. REVIEW FILE: 91 -305 FROM: R.S.B. RE: EXITING REQUIREMENTS RECIEVED REVISED PLAN OF TENANT SPACE WITH REVISIONS" TO ACCOMODATE THE ISSUES OF CHAPTER 33, AS FOUND ON INITIAL PLAN REVIEW. ADDITIONAL LOW WALLS HAVE BEEN ADDED TO CLEARLY DEFINE THE EGRESS PATH CONTINUATION FROM THE ENDS OF THE EXISTING CORRIDORS TO STAIR THIS SERVES TO DEDICATE THIS EGRESS. PATH FOR NO OTHER PURPOSE AND THUS RESOLVES THE ISSUE OF THE EXISTING_ CORRIDOR ROUTING THROUGH AN EXISTING INTERVENING ROOM. MONITORED SMOKE DETECTORS WILL BE INSTALLED PERSUANT TO U.B.C. SEC. 3305 g, EXP . 5 . MONITORED SMOKE DETECTORS WILL ALSO BE REQUIRED AT ALL AREAS ADJACENT AND OPEN TO THE EGRESS PATH. WILL NOTE THIS REQUIREMENT ON PLANS. UNDER THE 'NOTED CONDITIONS THE SPACE PLAN FOR. THE NEW TENANT SPACE WILL MEET 'THE PERFORMANCE REQUIREMENTS OF U.B.C. CHAPTER' 33. ROUTE TO 'E PREVENTION BUREAU FOR REVIEW, 12AUG91 DATE 6 ' I . I PERMIT NUMBER "" (If previously issued) PLAN CHECK NUMBER � i " 30 5 TYPE OF REVISION: �IPi G1eAr loo 4U-ave. -r1 �e (J Lie (�►�,�r ebr fr1 ('¢- ). ' ! I ��2 SHEET NUMBER(S) "Cloud" or highlight all areas of revisions and date r cis° ►zAJ sue, SUBMIFFED TO: 'W eft+ t IGTo 5r. CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * * REVISION SUBMITTAL * * RECEIVED CITY OF TUKWILA AUG 091991 PERMIT CENTER PROJECT NAME MAN C J 1 cn 1 &Ieo &.' B -c!< arr IQ13telovATi ) ADDRESS ! d4 5 a I j yr1 U K 3 AlN! CONTACT PERSON Th L)97 L k:Po14 PHONE 332-15 ARCHITECT OR ENGINEER ' k/ k hq.vtc. 64,IF' kid Is J-fl .7 p� � r � k tvl 4' '11.' /Q°d `K.., 1 40^-0 glso VI,04.. sL-t k k )' t 1- alc,kt e,fir e9J f)1/-(, , Vet j August 7, 1991 TO:. PLAN REVIEW FILE 91 -305 FROM: R.S.B. CONVERSATION WITH TODD LAWSON TODD LAWSON CALLED TO DISCUSS THE PLAN REVIEW COMMENTS. TRANSMITTED 1AUG91.. CLARIFICATION OF CORRIDOR ISSUES WERE REQUIRED. TODD PROPOSES TO USE THE SMOKE DETECTOR OPTION ACCOMPLISH:. THE T.I. WITHOUT PROVIDING FOR FIRE RATED CORRIDORS. GIVEN THAT THE BUILDING IS FULLY SPRINKLERED, THIS IS ALLOWABLE SINCE THE OCCUPANT LOAD OF•THIS SPACE IS < 100. (ACTUAL =67 PER TABLE 33A) ON THE ISSUE OF THE CORRIDORS BEING INTERUPTED BY AN INTERVENING ROOM, THE SPACE PLAN IS TO BE REVISED TO PROVIDE FOR LOW WALLS TO DEFINE A PERMANENT EGRESS PATH FROM THE ENDS OF THE. EXISTING CORRIDORS TO STAIR NO.2. , IN CONJUNCTION WITH THE SMOKE DETECTORS THIS WILL ACCOMPLISH THE INTENT OF U.B.C. SEC. 3305 TWO ,THTJSPROVIDING AN EGRESS PATH THAT MAY NOT BE USED . .FOR ANY OTHER REASON LAWSON TO. REVISE PLANS, AND RESUBMIT. CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUKWILA, WASHINGTON 98188 August 1, 1991 Mr. Todd Lawson 71 Columbia #302B Seattle, WA 98104 RE: Plan Review # 91 -305, Mancini /Grosbeck,Inc. Dear Mr. Lawson: An initial review of the proposed work for this tenant improvement indicates that the resulting space plan will not meet requirements of U.B.C. chapter 33 ( exiting requirements). As a result of opening the entire floor to one tenant, the existing corridors are . required to serve an occupant load > 30, therefore the corridor is required to be 1 -Hr. fire resistive construction. Requirements for openings in corridor walls must comply with U.B.C. Sec. 3305 (h). In addition, the corridor layout must meet requirements of U.B.C. Sec. 3305 (a) paragraph 2. Since the proposed work to this tenant space will create the non compliance outlined above, A revision to the space plan is required before approval of this permit application can be achieved.. Please review the code requirements for exiting, and submit two copies of the resulting revisions. If you have any questions regarding these requirements please call meat:206 /431 -3670: Sincerely, Robert Benedict° Sr. Plans Examiner PHONE N (200)433.1800 Cary L. VanDnsen, Mayor TO: FROM: DATE: SUBJECT: CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD, TUKW /LA, WASHINGTON 98188 Gtet) ���- Z2 - d t_ D y �,r>� -N/� Di - �XSC�QS2 �D AWx 6 v- ACC u 4 560 A r� bk9c66a.-Apppeop) cwcrto crIAL (1/14_0; og MEMORANDUM PHONE # 1206) 433.1800 Ctuy L. ra»Dusc», Mayor 4205 ibelhfr erf ed ak/1027/ I vot !, ,' 6C2) LQ4 (. (7`t'1 cOk lQ- X$8090 7 j 50�TE KUI( QN VEN yVIt Y W SHIN N ; 981 4 $ 4(31p5 ?r :` FA ( (2 ?:? 4() 9 » {���.P' Ufa' H1N %.L�.+•r:fJ�TwS ±,af.+'�h',N.Yw �+. To: Tukwila Permit From: Mancini & Groesbeck /Intersales, Inc. To Whom It May Concern: Todd Lawson is authorized as our agent for, ('Six 'Star) .to submit plans for some minor construction in our building. n 161HS INCH 111F: E:L .. . . t . Contractor to disrupt existing tenant as little as possible : They are to remove existing tire door and separation wall latest possible time. 2.) Where there is question Ora quality, color, type, and style the Contractor is to refer to the existing space for like example. 3. The Contractor is to notify the Architect of any omissions, changes, or errors in the drawings that affect the scope of Work. 4.) The Contractors bid shall include all items that will be needed to complete the Work according to building code and level of existing craftsmanship. 5.) Contractor to provide dust separation between existing tenant and I, construction area. 6.) All spaces shall be clean and ready for use upon completion. IIII II�I JII 4 5 6 NflTE : If the. mi rt-nf i 1 ,it,I rlreriii,er.r SEPARATE PERMIT AND APPROVAL REQUIRED Sy., cI1 OF TUKWii.A APPROVED' AU G 4 1991 ed . pi N i e tscknow : Poll* i o.."..,..tl .tl.'.tl...,. 7 8 4n 1 n n n +..4 Z FILE' COPY ! uncierstand that the Plan Check apprchAis sublet*? to errors and omissions ar ans does riat authorize the violation of adopted orth tance. Raceipt of c y of a ire I of .• .. ^....4.......•..N 4 .A... 3 ....•e6 ... 6 . 6 .S.II•40 60 ..v0 Of66 H6/ stpe HAU& INIP..LJR..f3AN J\DDR. 5s :11 501 I l•ITEFUJRJ AV, 50 TU K 14ILA War E650R,, 3365901'3 D 5C-IRI T ION ON TH 5540Ni FLOOK OF TH15 X IST E3UIl.PI NG TH COW TRACTOR k IL0L Fz44 1Ioy• Ex1'rIt)G- i i AcNC.7 tie)`H--SiguclU L rA N UNfr " 0 1-1.ALF51. Itit ONE 1 erAcepz,, i1 'A 1P ;`T° Jt coNTKACreg SLR. R51.06AT AN A P PreAS „AtNIP As - sHaiN ON kN illi"i�l i�llllllIl�III�I L�IIIII . LI` . ILI LI`I 9 10 11 MADE IN GERMANY 12 .. _....a s.. PEC IVaD (Iry n; Tt % IKA AUG 0 9 1991 !PERMIT CENTER 1Jo, A G D F G DCV , 661.-1 ctrr 2 2 51z 3` i 1I STORE PR, GLASS T EfrI it TEMP Fi>J 15(- N oTeS STAIN . REL4T5.1p 2 io x7° 14t7 — _ 0 i SUILp 'tn (:x. OIJNINer Pa I 2 - I° x7 14p II 1 NO.) BI•FtLO Doa2 S 1) 1:a71?-.. S T'0 15 KErINISI1Ir17 TO H 4 X IST /Ncr I rENANT //.11S1-)ES HARM-JAKE' -0 5 eRusrMP GH Roii F. i N I S j To ' ATGI -( I xI S"17NG ScAL5 �-- NEW BI - L'D SHED F4 Rev CITY OF TUKWILA APPROVED KEY 1 5'-a" GW $ NEW PULL HEIGHT ►�B WALL 5X16TI -1G 1 ULI- IGHT WALL x IS - ri N6 - HALT~ WALL SCOPE Ni oF To �1 =t�IO L 15 D (pAT R� %DUTL .1 ; IRAcK LIGHT AVM • TuMGTIoN I X I LAC, CON 1 T� TENAY.JY 6 ) -- 51N-1 BUR I ITi1Fz5._ . P,IRUtLs @ 1 )8'' A13av - p REL Es t7 GAS 1 II Rio✓E -- r � -� WALL I I � . 1 I I 11 Rai= irl1 co FIB c , I 11 �► ®- —o -m �L • I - c rrra- O FIG#s NO3 , RE EVE SHA > .STPIP EGKt'SS rATH io KEMAIN C.LEAR, AND }IAvE 5Mo KE T -cTorY 5 INSTALIZO , c1tegAWc MTH AND am- LNG Lq;riW r povigemeoTS, TODD LAWSON PROJECT DES1 N 71 COLUMBIA #302 SEATTLE Wk 98104 ( 206)392- 9585 SECOND FLOOR 9 ! t n IA • losr examwes.m.• I .1 ., ...'.. �. �• :.. IIII��III�II�II�ILII�III�III�IIIIIIi� ► �►11 �` ��` r�lll�lli�I�I�II�1i! I�I�111�1�11! 1111�II11111�11111II�II111I1( I�11111�1�111�I�I�11111�11 111�1�. I111II�IL�II�I�11111I►�I 111111111111111111 0 le MS INCH 2 3 4 5 6 7 8 9 10 11 ..MEINNRMANY 12 Iz MME c(ST HALE NALL Rg14c. W ITh . FULL HEIGHT . MALL ALTER GI =ICING As NEDt 5A1( •l5Ti au - 11Zr/ NE Hew 2e°X se- GL465 6u,5L &HT mourns) 5M Destscrotes VeislotZED roe 44:1A•44251:16 . Ab' 4 °)<7 ° OPE=NING I ' I °x 5° 5Lpc LIt'skrs RaCEIVED (ITV (14 1KWILA AUG 0 9 1991 PERMIT CENTER NoTT 13u114)an 6. 4u :Fpp W /AUTO 5PIUNKLE AND SM OK vtTeCr0 S 1,4" IK1,C.m. d Na3 1-4 WALL FILE COPY, 1 understand that the Plan Check approvals are subject to errors and omissions and oval of Plate does not author fze the violation of any ackpteci co<4t or ordinance. Receipt of contractor' copy of approved plans aciulowied• Date...............•........................... .. ..................ti Permit No.... 0 .6THS INCH 1 2 3 4 5 6 7 8 CLVA AN A E '' , 5EV,../0N D FL oo . \ -FHAS ' ONE 1 1 ( 1 1 1 1 1 1 1 1 1 1 1 ( 1 1 1 ( 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 l' 1 1 1 1 1 1 111 1 1 1 1 1 1111111IIII11' 1 1 III 1 1 1 1 1 1 1 I 11111111I 111111 9 10 NOTE: If the microfilmed dncument is less clear than this xts`c' FULL 14 - n ` e G N 5'-0 TALL I'4/7 GAP. WALL. 1 ' Kemo D I2x15 C S &d LL WITH IIIIIIIIII'IIIIIIIIIII�It 11 ► ING "MANY 12 REmov: c R pg014 s - TWO 5, rot2 flaCHINC 5- rfli:, CITY OF TUKWILA APPROVED OCT 4. 1991 411 s BUILDIN D �, ION • RECEIV v CITY 0 F 7 {l F. op ow( SEP'27 P ERM I T ;VTR .on Ida