Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit 6769 - Boeing #12-126 - Partitions Removal
6769 91-350 boeing #12-126 18300 cascade avenue south 6769 91-350 boeing #12-126 18300 cascade avenue south Permit 6769 - Boeing #12-126 TYPE OP CONS777 _ UB D year 1988 SETBACKS: N — S — E— W — FIRE PROTECTION: ®Sprinklers 0 Detectors 0 N/A UTILITY PERMITS REQUIRED? OYes ® No BAR /LAND USE CONDITIONS? 0 Yes (thrbug Publ ic Works 0 No ZONING: CONDITIONS (other than those noted on or attached to permit/plans) WA. ST. CONTRACTOR'S LICENSE # ALPHACC131P6 EXP DATE 10 -05-92 ARCHITECT PHONE ADDRESS IZIP PROPERTY OWNER Boeing PHONE 723 -0444! ADDRESS P.O. Box 3999, Seattle, WA ZIP 98124 CONTRACTOR Alphase Construction Corp. PHONE 862 -0328 ADDRESS P.O. Box 7282, Sumner, WA ZIP 98390 WA. ST. CONTRACTOR'S LICENSE # ALPHACC131P6 EXP DATE 10 -05-92 ARCHITECT PHONE ADDRESS IZIP CITY OF TUKWILA Dept. of Community Development - Building 6300 Southcenter Boulevard, Tukwila WA (206) 431 -3670 BUILDING PERMIT NO. DATE ISSUED: SITE ADDRESS PROJECT NAME/TENANT Boeing x/12 -126 DESCRIBE WORK TO BE DONE: Remove demountable partitions. APPROVED FOR ISSUANCE BY: SIGNATURE: JY\ PRINT NAME: CERTIFICATE OF OCCUPANCY NO. (0 18300 Cascade Av S Division 98188 BUILDIU PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) BUILDINGPERMIT:FEE PLANCHECKFEE 1 ;35' 00<;; BUILDING SURCHARGE < >: >: 346.5 1 8- 2.11 -'91 1:.5:35; :.. SUITE # BUILDING OFFICIAL DATE: DATE ISSUED: VALUE OF CONSTRUCTION - $ 20,000.00 ASSESSOR ACCOUNT # 788890 -0175 TYPE OF • New Building ■ Addition © Tenant Improvement (commercial) 0 Demolition (building) U Grading/Fill WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) 0 Other: CODE , CON1pilANCE USE LOOK �' SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. TOTAL TOTAL LOAD SQUARE FEET OCC. LOAD I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performanc wor>c. I am authorized to sign for and obtain this building permit. t, COMPANY: Pi_ l nr' Ct�n5 h . C_Dr ► permitshall.become ii tan d word rtahe wor n ot 'commence d within X 80 days front the date:: PERMIT NO. CONTACTED 1 Y1e�so. ec . DATE READY DATE NOTIFIED Q t ) (init.) BY: (init.) PERMIT EXPIRES 2nd NOTIFICATION AMOUNT OWING ,r l�J 3RD NOTIFICATION BY: (init.) f BUILDING(: ?ERMIT APPLICATION TRACKING PLAN CHECK NUMBER 9 1'55- INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. PARTMME &BUILDING - al - a 8 40gl initial review (ROUTED) IJ FIRE /zyYg 111,1\ �. INIT: O PLANNING O PUBLIC WORKS O OTHER BUILDING - final review Rl tATM REVIEW COMPLETED PROJECT NAME SITE ADDRESS //4 INIT: INIT: INIT: INIT: T ROV /0-6r19 SUITE NO. I �3 Cocad_e_. Nv CONSULTANT: Date Sent • ZONING: REFERENCE FILE NOS.: TYPE OF CONSTRUCTION: UIE: EMEN MINIMUM SETBACKS: N- S- 5:; FIRE PROTECTION: (✓ Sprinklers 1 Detectors ( ) N/A FIRE DEPT. LETTER DATED: 27 / INSPECTOR: r) 7 UTILITY PERMITS REQUIRED? Yes PUBLIC WORKS LETTER DATED: ME..TS:: Date Approved - BAR/LAND USE CONDITIONS? UBC EDITION (year): ciOS TOTAL OCC LOAD Yes No O8I17IO SITE ADDRESS SUITE # \ :l7 () C11 -� :C. c: -A O . cj., - VALUE OF CONSTRUCTION - $ 62o, oil - a 7 ASSESSOR ACCOUNT # PROJECT NAME/TENANT TYPE OF O Ne Building • Addition P Tenant Improvement (commercial) • Demolition (building) WORK: O Rack Storage 0 Reroof • Remodel (residential) Other DESCRIBE WORK TO BE DONE: cke fr o e_ c�c. mou 9ctr -- • ; c-\ ■a _ (-2 t c ( .A -. a. BUILDING USE (office, warehouse, etc.) NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? 54 No ❑ Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building:X Tenant Space:X Area of Construction: k 1 4 WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? p No 0 Yes IF YES, EXPLAIN: PROPERTY OWNER S r y PHONE 1223_ 0 ,4'44 / ZIPc tc5 I ��/ 1 ADDRESS ' ,(� ,R.,),,),, .`2 9 ., S \v �-LJ�. • CONTRACTOR 1 t 1►- ,. 41 lk PHONE l-� ( 3 (of a��, I5 ___ ADDRESS '7,9, , cw - `rr\ r\c�Z �-cO� ' ZIPc ca 39 . WA. ST. CONTRACTOR'S LICENSE # R�y,4,(:)C c (J' P � EXP. DATE (27 PHONE ARCHITECT ADDRESS IZIP CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER IEREBY CERTIFY THAT :1 HAVE READ EXAMINED; THiS A PPLiCA710N AND BE TRUE AND CORRECT AND THIS IZED.:i:TO:APP,LY OR.THIS,P.ERM {T IGNATURE ,- T BUILDING OWNER OR AUTHORIZED AGENT CONTACT PERSON DATE APPLICATION ACCEPTED PRINT( X r l ADDR -§ T BUILDIN PERMIT APPLICATION DESCRIPTION BUILDING PERMIT FEE PLAN CHECK FEE: BUILDING SURCHARGE OTHER: AMOUNT TOTAL . :;j ir? RCPT. IT val DA DATE APPLICATION EXPIRES W; PHONE '` 03,9 CITYIZI PsGc rrt, e, 9R3 9c. PHONE APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and Is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT if the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. S 63/16/01 COMMERCIAL • . . NEW COMMERCIAL BUILDINGS/ADDITIONS • . • • n Completed building permit application (one for each structure) [7] Assessor Account Number . . • . Two sets (2) of the following:" • •• Specifications ri Structural calculations stamped by a WashIngton State licensed engineer Soils report stamped b 1 a Washington State licensed engineer . • Li Topographical survey • . • . •.• . .E bY ;i'.:Washingtori'State licensed engineer or architect .:••.:., •:: ••••, • Legal description :'..••••;':,:::?; • • . Working drawings stamped by a Washington State licensed ..t architect which inClUde:• . . • Site plan • • Architectural drawings -•,.. .„ Structural drawings Mechanical drawings Elevations • •••.•• Landscape plan • pioject), Six (6) sets of civil druNlngs NOTE See utility permit application and check/is; for specific utility • : . . ' ' submittal „ • .. ' '' • . .• . : ... • . : . . • .”. . RACK . : . . L I Completed building permit application ....AsSeisor:',Aczount '.NuIrnbef . . • .• • Two (2) sets of : plan s,":whicti, include • . . . • ••• Entire space where racks will . be Exit doors •••••:•';'•-• ' -.• DiMensionS of ell .aiilea.".:*".• • ',";••••.::::•:::• • .ri Tenant space floor plan showing rack storage layout, aisles and „. ••• e .. . • • NOTE Include dimensions of racks (height width and length) aisles and exit ways on plan Structural calculations stamped by a Washington State licensed engineer (rack 8 and over):i • ;.: •;•;•: I . . - RESIDENTIAL NEW SINGLE FAMILY . „ .. :„. . . ... Completed building permit applicatan (one for each structu a) Legal descnption • • • , .„:.,....... El :Assessor Account Number . • TwO•.setS":(2)"Of 'WcitHng drawings which include • : . SUEMITTAL CHECKLIST • ..• • .. • .. • COMMERCIAL T ENANT IMPROVEMENTS Account Number 1 Completed building permit application (one for each structure or : tenant) Two (2) sets of construction plans which include tiie plan Existing and Assessor proposed parking use 1:::17:17.7• Landscape plan ... . . apPliaa ". building plan • • Tenant.location . ... Use of adjacent (common wall) tenant • '" • . " Overall dimensions of building or square footage . -•.• • • • • ••••••••-." Floor plan of proposed tenant space . ... ••••:- 'el • Exit doors egress patterns New walls existing Well;inclWalli•ta' be demolished I • ••••• • " • " ..... • . . Construction : • Cross sections showing wall construction and method of • Structural:balculationS"'Stamped'OY".0:WashIngtep:tate licensed engineer May be required if structural work is to be done (2 sets) : • • . , • . NOTE If any utility worlds :to ba.done;; separate utility permit • •-•-•• • .application and . • :,,...: • . ...: :•:•:::•,..... . : . ...::: . . . .:.... F t EtIpp ....,......i::::.,, •....-:::•::....•••‘T,..,••'..•:,•:;.•.•'.:.:•:::':::::.':!..:••••:,:::::::,.;::::::',.,,:::-..,'.::::::k:•::::.i.:;!:::::':ii',:::...i :::::::::: . ':•Completed'bilIItdh Assessor ---- - •-•••••• • ... Ac „,,,,,,, e.:::::„::::::: , .:::,::::::::,, , ,„:::,::„,:::::„.::::.,..::.,:::::,::::: : :,: : : : : : :,„ : : : : : ,..„,: ; ....„....:,,,,. : „..„,....„.,,. , ...:: . :'•••• . - de s cribing ,rin '... iiitin roof;•:•material:being rpnlq■ie0..:0 ....„ . . . ::::::::::::::::::::::::'•:' ,' .',.:,.:..., ,:,,-.7,,, c .....•::::::::: .:.:.:..-....:.:.,......::',:::::::,,....:..../.,:--,<,, NOTE ':::ii 'iiitifidaiidri101ti,ii i? i ?ft:.?!....! / ...!P . 1'?! . T I ....';'::: : :......:: .. ..,:::,....:,:r.'.',.i...:: . :i7 . !.:-.1:g::::::::::::::: . :::;.5::::::': . :'.';::‘::,':::' , ..::::i . ;:::::;:::::,::::::11:M::::::;1::::E. '...' ' • •-.: • - .. ....... .. .. . .. . NA/SATELLITE eOriiletod:bUildinglpermit application Assessor Account Number • • ..• •• .• ” .•"" " •••Two (2):sets'of which i . Site Plan (showing buIlding and location of antenna/satellite ciis DetaIls anterinalsatelllte dish and method of attachment Structural ...:.„.; . calculati ... ............................................................................ RESI REMODELS r Completed „ . building permit aboliCation:(one;sqrea01 Asset or'AcicoUnt Number Two (2) sets of working drowlings Site plan • Floor plan .............. . . • ' Building .... •...... Building ross section Structural framing plans NOTE If any utility work is to be done provide utility permit epflcation and plans plus! be submitted . . .... „ Completed building permit application (one for each structure) Narrative describing existing roc) e m , • material being installed:") 7. NOTE: A certification letter Is required prior to 1001100000 and sign PROJECT: /' - /Y4 PERMIT NO. 6769 SITE ADDRESS: / /SOD (/ . - i e-e./ ‘e.4 c- e.,.5. DATE CALLED: 9 -,2c,G DATE WANTED: .9— p .77 - REQUESTER: /J.A.r -r✓ la TYPE OF INSPECTI • G -jc'rc . .C� . , O SPECIAL INSTRUCTIO �j PHONE NO.: 041 -9,c// oed "& INSPECTION RESULTS /COMMEN `' tr DATE: 4 21 ' ! ( INSPECTOR:. \,L52,— r..n„a k:4H .rp , 12, ,,,r a•d'.Y+ +u-Ywn:L +t'YT }thv wy:n w• cm' OF T U16WIL4 Dept. of Community Development - Building Division Phone: (206) 431 -3670 �4a rYt tut NSPECTIO6 RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: ■ k. - ( LLQ PERMIT NO. lY 1 (_r? SITE ADDRESS: % co fib 4k_3 LA 1 , I DATE CALLED: 1 --9 TYPE OF INSPECTION: 12 (ITVI ( 0 C DATE WANTED: 9-- a = -; SPECIAL INSTRUCTIONS: REQUESTERY l ct PHONE NO.: 7(1 6a4 -QN INSPECTION RESULTS /COMMENTS: C r c iv„.t r INSPECTOR: v DATE: ¶'`I k ) CITY OF ruKw1LA Dept. of Community Development - Building Division Phone: (206) 431 -3670 v.,.u.r.,,. �. +.:.•..n¢hN.... -•: E'x sF GF.rv:q; >'.Y' nv.yuN:.V4.idF': INSPECTION RECORD It ^.u.'F 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: 2' 17-4 PERMIT NO. 0 q C9 61 SITE ADDRESS: I t ' ?j 6 (A- P(Vt. ` S' DATE CALLED: ( 1 - ) Z ' 6 / I +., TYPE OF INSPECTION: ' N ' 4A DATE WANTED: o v i �I -- `40 SPECIAL INSTRUCTIONS: REQUESTER: / ai(,---d e / PHONE NO.: Gj I INSPECTION RESULTS /COMMENTS: 'AI A...s... C 4Ns-lfatia. ja-4^-- ! A.A.__ INSPECTOR: DATE: C • AC iarte gr. CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 • !NY, INSPECTION RECORD 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 PROJECT: rip •`e_ /l 4 a s D PERMIT NO DATE CALLED: ( () (Oq d " � I „� SITE ADDRESS: ! ..... / `ke • 1'01 .3 TYPE OF INSPECTION: ( ` i'1 i'1 ` DATE WANTED: REQUESTER: q-1,.._cti OciLI0n `ghbl C»� • �-• SPECIAL INSTRUCTIONS: PHONE NO.: INSPECTION RESULTS /COMMENTS: //o / e",, -, f.ra /� f --- // c, 4,G, (5. 14-.1 r - ,�iC ..- 9 ' 4 - l__ - t/ INSPECTOR: T/' . a _ ..- -- ) DATE: -- /' - ?--9/ CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTION RECORD "P116 6300 Southcenter Boulevard - #100 Tukwila Washington 98188 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Retain current inspection schedule Needs shift inspection ■ FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Gary L. VanDusen, Mayor Control No . I - 3 5 Permit No. r'' Project Name I V- / `• Suite # Address AE j �'!;�"'7 � r , ,4-��, ), ..� Approved without correction notice ... with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon : t�l Monitor: Pre Fire: Permits: vw Authorized Signafiur, Date FINALAPP.FRM T.F.D:..Form F:P 85 CITY OF TUKWILA 6200 SOUTIICENTER /BOULEVARD, TUKIVILA, WASHINGTON 98188 Plan Check #91 -350: Boeing #12 -126. 18300 Cascade Av S I'IIONE II (200)433.1800 THE FOLLOWING COMMENTS APPLY TO AND BECOME 1 ft THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER 11"1 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (872- 6363). 3. All mechanical work shall be under separate permit through the City of Tukwila. 4. Al'l permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 5. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 6. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 7. Any exposed insulations backing material to have Flame Spread Rating of '25 or less, and material shall bear identification showing the fire performance rating thereof. 8. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1991 Edition), and Washington State Regulations for Barrier Free Facility (1989 Edition). 9. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. Gary L. VanDusen, Mayor "X" REQUIRED INSPECTIONS PHONE DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 R 7 Framing 431 -3670 8 Insulation 431 -3670 X 9 Suspended Ceiling 431 -3670 X 10 Wall Board Fastening 431 -3670 11 12 13 14 FIRE FINAL Insp: 575 -4407 , 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 x 17 BUILDING FINAL 431 -3670 CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: 18300 Cascade Av S BUILDU*G PERMIT INSPECTION RECORD (Post with Building Permit In conspicuous place) SUITE NO.: BUILDING PERMIT NO DATE ISSUED: PROJECT: Boeing #12 -126 CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (INSPECTOR COMMENT SECTION ON REVERSE INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if underslab insulation Is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. m,,,,,00 Plan Check No.: 61 11 -3 5 - 0 Project: 2- I Z REQUIRED INSPECTIONS PLAN REVIEW COMMEi4. S 6 ( 1. No changes will be made to the plans unless approved by the Architect �--� and the Tukwila Building Division. 2. Plumbing permit.shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277- 7272). 0 . All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). All high - strength bolting to be special inspected (Sec. 306, UBC). Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). 17. All construction to be done In conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear Identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special Inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. 1. Footings 2. Foundation 3. Slab /Slab Insulation 4. Shear Wall Nailing 5. Roof Sheathing Nailing 6. Masonry Chimney Framing ili 7. 8. Insulation 014 9. Suspended Ceiling 10. Wall Board Fastening 12. 13. I ll. 14. Fire Final 15. Planning Final 16. Public Works Final 17. Building Final Plan Check No.: 61 11 -3 5 - 0 Project: 2- I Z REQUIRED INSPECTIONS PLAN REVIEW COMMEi4. S 6 ( 1. No changes will be made to the plans unless approved by the Architect �--� and the Tukwila Building Division. 2. Plumbing permit.shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277- 7272). 0 . All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). All high - strength bolting to be special inspected (Sec. 306, UBC). Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). 17. All construction to be done In conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractors responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear Identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special Inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. DATE — PROJECT NAME ADDRESS ®ems CA C i g CONTACT PERSON JO i ARCHITECT OR ENGINEER -2 i BO,EZ VG' CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * * REVISION SUBMITTAL * * Co 504 /p47-E S Z PERMIT NUMBER (If previously issued) PLAN CHECK NUMBER 9 / 3 S O TYPE OF REVISION: "Cloud" or highlight all areas of revisions and date revisions. SHEET NUMBER(S) k /!& 0 9� -- A l John S. Murdoch Building Codes & Permit Management Facilities Architectural and Engineering Department Aerospace & Electronics Division Boeing Defense & Space Group P.O. Box 3999, MS 89 -14 Seattle, WA 98124-2499 Telephone 206 -773 -0444 Fax 206- 773 -2432 PHONE 7 �'" 7h SUBMI` TED TO f:1 D IO 5 � ,4 5 1 FErimr CENT gate elevation typical edge section consolidate esd typical edge section gate elevation corridor CIR FRAMES AMPS wire load PANEL /°C ELECTR ICAL PANEL SCHEDULE BLDG 7--/e6 - / DATE 7 / LOCATION Cot. 8 -7 dTuiry Roots CA'T Low TYPE c. E . 40 7M 4E420WSC3 za4D crR FEEDERS '1 f' / #1, GREEA/ /V 214 "AL MAIN BKR. Zoo 4 , ' i° L8' FROM �'.S KVA 61A? BLOW RATING 'OoA . /2o zoB�W' E - 7 - ms PAM osioks C VI G , eO/IN.D BLOCK 4v.57 ' CONNE REFERENCE DWG. NO. 1Z - 1 1✓ / � REVISED CKT. I) c- REVISION L DATE REVISED a lo• /`.1 ENGINEER_ _1Jt t JOB NO. "116053 -0 • " RE FE RE NCI DWG, NO. '67 - /26-240/- . ./30 R,E)/kSIONL. ,E NGINEER , 611 tirEWref L. TING s/2dL 34 9 L/ 2.064 • ELECTrical PANEL scHEdule. BLDG DEt LOCATION E3 7. tows FEEDERS 32. FROM • PN H v a Vt& REVISED CKT. 131 .DATE REVISED t JOB NO. 1,15073•4=cP•V • 'LOCATION ;;:!: . 71,1 ,,_:. .P.1i0•2d i. CO Eii,:!1:i L. .T E ': ii ;',.. ii. •:• - ;..:: .. MINN . : ,:,.:.,: i : ' , ; •■; votli BROMBEMEMR:j i! • ,5 T.v;Fil . powsr ammiles!: .,. j R ' • 113 IBM . ( 1 A•sek - £W • , 1 • I I MM. IIII Wilnialla 1.111:1 BIM . . . . titii.111111111111111111111111111111111111111/118 MN MINN MUM . . .....1 'Z. gg.i 011111111111111111111111111111111111110101.1111111111.1111M1111111 ,. E V MOM NI MINIMMISMONONSWV.Mici 0711:MIN011 Mir.A1010M, .N ' , `: J 7:!: . . WI viriltr,. 727 0 1pl av r easslana tfittIM miss "'.:4 Illef WieNfilE M 1121S. • . • • • . . • • .• , •'..ys ....zt: i i'llivowelptc•ea:70t". WiNt itait NAM 'K . -1 MieittS 1 . 1 M 1 1011101100011000000 0 .14ONSMIIIMINVe . 11. 11 1 i 111111111111111.10MMINIMMI1$PINOMMIENNOM INN imp ppm • * WailikittitOW1 i 5.5 e4 tatiaiii.:;:i MUM Olahlaili0110111.11111 MS 1111101.6111111 'ten IIMWPOGSIIIMIIIIIIIMNNNEIIEIIIIIIIIIIIIMIMNIISIEMIIIMIII NMI XISEN NeallIMMIIIMera; . .1 11 EV.1110111111r4111 IMP I IN NI C- . ism .1 ralrhMII. !Aral NIIIININI . •-;vs......0.1•-•• .. - • ....- , SWIM PRIN .:, . 7 ... . MAIM - . :-i•:i ' • ... :, ' 5f RAMENNIMN NM WA WEISMINI. 'tlfj,VA ... I' . ' Anirellasim ElliiffE401PWANIEWOMMIZEMIONNIIIIIIN sasia usalaiiMunittiagu 1ArMS11110111 i' • '':.• 'j .:70.2 , ' , ',INVENINNE • .., ..: FS 1144 . ',romiNNNN* t' IN • ie4:,.,,i,„.,• ,,!, Wi rimsrbile . 1-111111 18 : 0 wan ie 7; ..11:1 111111:11:111111111 61.1 A rimilmm: ;:iii.4 z14 ■ii :iMlii, $1144*1!i;Itif44' , ..;:tiii! , : ; ';1;4Iiii; Ifiiii;.ii , ;;;!,.,;!, ENTRY t:ITES 1, • f . "" r – k•h : .,' co .E• • • RE-'s 7 • PiS - 14/ES ..., • , A " ' ' 1 1 '' ' ..1111111 tn. MIN NM UM IMOMMICEEMBEI MINN NW , • . .. - :;. 1 1 1111111.1nal . HERIV: MiglinVii:; i gi. % •• 1 1 ' .- • ' ' . ! DI ' la r1 1 1 76VMPB1 . •. t 1 ';), . : • • i ; : : At] M le I X 9 it taillWaj MI g a if01 f LA170 ;24mM Itn 7MrliV7ttr OP TEpragig.**greigligAVOIXI. g UMW= ONIMMRNVtiv''' ‘ - • . • • ' •i:,;::::7.• :: :: 1 iin kiTil,R TYMP•PW, Wagrqgrg-`0%10.giAr 0:•edgC4V lienvlsol AIM ININTRMIsMorkt:*; .. ..• •.•• • • • . ••.. •• .• ..• .•v,••• - rom *an* fffirgii,WZ150 :g 4g ifff ,' WA -115,4W afif - WWI MiIIINIMIIM NIVIROMMOMPAMMWRINIMIM PIMI OROP, NW • • •• . ••••. • . • • .: • .:: 1 ; 7 FVffiatira 711571infl l'. - " A..414 . „,, .. . . r „„ 1 ,,,.-, ci-, ,,,,,,,,,,,, ,,,,,tpc. ra•;:wismr...vo&ntprilrisfrr';' A 4 ',;,..i;.:.;...; ,::....41::,.•W4. i: ;A ,z ' 941,KI;LA,- . MI!' f.' . OW ' ' a's*. ; A 1.-SPMV:Xar r q.. 'r :).-• • ' iv 'w.. ..• r .. .77 --- 1;71,v,ZTr7 77 37,. '17 1 PIT .r7, 7.3:7 1 • . • WIRE SIZE " •• A CIR FRAMES M SIZE LOAD TOTAL PANEL I TYPE G-1,c r .:f �) MAIN BKR. tk70E RATING ?�e 11:+4/ L.0 est , 34 4-W ELECTRICAL PANEL SCHEDULE BLDG I' . -1 Z(c) .t DATE I L -9 —awl LOCATION 2M w I ML4 f FEEDERS ,_12/4.. , 2 FROM ' 1. Ik .. VA10 WITh A 1ooA • c.4.5E ON s ..ri+ •'} REFERENCE DWG. NO, t Z- •/26 - 2E4 I REVISED CKT, REVISION DATE REVISED ENGINEER JOB NO. CIR FRAMES & AAAPS WIRE SIZE LOAD PANEL P 6' TYPE 6E:" N LA S MAIN BKR. 3 P- 200A -rtc i RATING I20 /Zo9V, t.dQA 1 545 % + 5) REFERENCE DWG. NO. - t 24 - 2E6 I REVISION ENGINEER ' ELECTRICAL PANEL SCHEDULE BLDG t2=12‘. '38 DATE 6- it -8 LOCATION 2 — FL Z.. FEEDERS 2' . , 4 # 4 ./ FROM p�1c. Hv A1 -k. 1a. 5c vow 75 *REVISED CKT 1 ' DATE REVISED 40 2tt 413194 JOB NO 'y` CIR FRAMES & AMPS WIRE SIZE LOAD LOCATION MIG M O SPLAY Cq ) Icaoti) PANEL 1 TYPE 61E. ' A.C1' MAIN BKR. -10 A 'rNQL. RATING 11.0 /244V., paDA. i a 9W REFERENCE DING. NO. 7 REVISION, -• ENGINEER 'N • MENTY?) ELECTRICAL PANEL SCHED LE BLDG 1' I lao DATE (o- « LOCATION V7 (6.QUIP. 2M) itIrk2 FEEDERS II/4" 6.-ti FROM PNL PA/ F SK R, 4 REVISED CKT. 25e, 3 ,3SL DATE REVISED S /la /`Ii JOB NO l s 50 9s --oD Dear Sir: City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review Control #91 -350 (513) Gary L. VanDusen, Mayor August 28, 1991 Re: Boeing Company Building #12 -126 - 18300 Cascade Avenue South The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. 2. Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 10.402(a). Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) 3. Maintain sprinkler protection for all enclosed areas. (NFPA 13, 4- 1.1.1) (UFC 10.302) All sprinkler drawings shall be prepared by companies licensed to perform this type of work. Drawings shall first be approved by the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528 & NFPA 13, 1 -9.1) (UFC 10.305) 4. All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NEC 70) (UFC 85.101) 5. All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and • City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) Gary L. VanDusen, Mayor All interior wall covering materials shall be fire- resistive or shall be treated to be fire - resistive, so as to result in a flame- spread rating as required by UFC Appendix VI-C tables 42A and 42B. A certificate of the flame spread rating is required to be delivered to the Tukwila Fire Department. (UBC 4204) (UFC 10.401) The Tukwila Fire Prevention Bureau PLAN REVIEW: 91 -350 PROJECT NAME: BOEING BLDG. 12 -126 DATE: September 9, 1991 OCCUPANCY GROUP: B -2, OFFICE USE TYPE OF CONSTRUCTION: V -N, SPRINKLERED LOCATION ON PROPERTY: N /C, T.I. LOCATED ON 1ST & 2ND FLOORS BUILDING HEIGHT /NO OF STORIES: 2, N/C FLOOR AREA: N /C, PROPOSED WORK WILL NOT CHANGE FLOOR AREA OCCUPANCY LOAD: PROPOSED WORK WILL NOT CHANGE OCCUPANT LOAD EXITING REQUIREMENTS: EXITING REQUIREMENTS WILL REMAIN THE SAME, AND NO CHANGES IN EGRESS WILL RESULT EXCEPT FOR THE PROPOSED GATE AT CORRIDOR. ORIGINALLY PROPOSED AS A STANDARD DOOR, THIS WAS REJECTED BY KEN NELSON IN COMMUNICATIONS WITH JOHN MURDOCH. SUBSEQUENT REVISION WAS RECIEVED ON 5SEPT91. THE BOEING COMPANY ORIGINALLY PROPOSED THE DOOR TO SEGREGATE THE SAUDI PERSONNEL FROM THE REMAINDER OF BOEING PERSONNEL ON THIS FLOOR FOR SECURITY REASONS. AS AN ALTERNATE METHOD OF ACCOMPLISHING THIS SEGREGATION BOEINGS HAS PROPOSED TO INSTALL A 42" HIGH BY 36" WIDE GATE (WITH LATCH) ACROSS CORRIDOR. A STRUCTURE SUCH AS THIS IS A PARTITION < 5' -9" HIGH THEREFORE IT' WOULD NOT OTHERWISE REQUIRE A BUILDING PERMIT. HOWEVER, SINCE THE LOCATION IS IN A CORRIDOR, THIS BECOMES A MAINTAINANCE OF EXITS ISSUE WHICH WILL REQUIRE APPROVAL OF FIRE DEPARTMENT. THE FOLLOWING RELATED ISSUES SHOULD ALSO BE ADDRESSED: 1. WHICH WAY SHOULD GATE SWING? 2. SHOULD THERE BE A LATCHING DEVICE ON THIS GATE, OR IS THIS A PROBLEM ? DETAILED REOUIREMENTS: OCCUPANCY REQMTS N /C. CONSTRUCTION TYPE REQMTS. N/C & CONSIS T WITH EXISTING BLDG. CHAPTER 23 REQMTS, N /C. BARRIER FREE 'EQ . N /C. W.S.E.C. N /A. 416 PREPARED BY: * D.C.D - BUILDING DIVISION * PLAN REVIEW * ROBE 'T BENEDICTO, SR.P.E. SPiceekX11-4)44-4-4 41-9LQ lace /11-)Leg/IA0-ra AfFIZ E10,liW U�U E f R G :1 1916 1 991 . 7 5 1 C , II August 15, 1991 4- 7300 -REW -431 Alphase Construction, Inc. P.O. Box 7287 Sumner, Washington 98390 Attention: Marilyn Long Subject: Invitation to Bid Boe,ig, No. 115093 Building 12.126, ESD Relocation Southcenter South, Tukwila, Washington Dear Ms. Long: You are invited to submit your bid to perform all work necessary to complete the subject work and attached. data Your proposal should also include a; completion schedule based on verbal Notice to Proceed. by Boeing, with completion on or before September 20, 1991. All permits will be the responsibility of the contractor including the Building Permit. Any questions may be to Ray Wolford Sincerely, BE &C Engineers immerman ruction Management REW: j e Booing Support Services P.O. Box 3707 Seattle, WA 98124 -2207 1 Or,,119.01 feet, an 'Arc di.40116) df 03,21 toodartikoi00111 ''.nilitigal,',61191* to the west line of said 4pel71 ": A • Thence N 1123' f 004 : 3110 . wt lihe 4400tance 149.53 feet to.the nor*est: corer of AOtd Lot 17, And - the 10 of the eight" Dank of the Giedil iliverr A Thence eh* said top ofthe' right bank of the Green River the following courses aed die tentes; S '44°20'00' E a Ms-tents 'of 60.08 feet; 5 59°4360" E a distance of 98.00 feet; „S' 72 t a distance of 101.00 feet; S 82 E a distAnce of 100.00 feet; N 78°64t00" E a diseepee of .90,00'feet; P1 6834'00" ,E- a istarice of 99:00 feet; N 73'0013" E a distance of 97.69 feet more Or . 10$ t the west margin Of Secondary State Highway Thence leaVingelaid-tep or„the rieht bank of 'the Green River along said welt margin ,oh a clieve to the tight, the oenter �f,hich bears ''N•47".33;2 W. haVing A radios n:a s of $43.14 feet, arc distance:Of 47,9* t Tough a: ntrtal Angle of 0911 Thefic*S41!310" W along said margin a diStence•Of 111:40 'feet; thee* alongit „curve to the eft, on said west margin, he4ing a radius 04p3;10ea:t AI Ore distance of 423.03 feet throUgh a central anOle Of 4014 ThilAce S 1 023 1 60" W Olotig said west Marvin a distance of 35.28 feet; ,Thence N'711°30'50" W a dittenee of 10.00 feet; Thente 5 11°23 la distance of 345.04 feet; Thence along e curve to the right having a radius of 50.00 feet, an 1 eel: diAtence 78,54 feet; I Theoee ti 78°36°10" ,W a dI t stencAf 185.00 fe th et to the true Point of beginning. • t Coetainieg 286,580 sqUare feet 'liar 6.579 acre. —I - e-- - 1 I- -- t t l t I \/1 Co scL 1. All materials and workmanship shall conform to the 1979 Uniform rioildirati, Mechanical and Electrical Codes and Local Codes.. 2 TyPiteV details shall aPply where no Sped fit Aetai ls aee given. 3. The Contractor shall verify all dirnensions, elevations and condi- tlens prior.to construction. - 4. Al) dimension4 are to take precedence over scale shown on plans, elevations, sections and details. 5. AII exit'dOors to he operable infde building WithoOt keys or spetial' knowledge. . 6. Work rl,etedte -tent improvement and required eelordination to shell' conqtr64ien shall be determined by the Genteel Contractor for bidding And contracture] 'agreement. 7. Walls are to fireStopped per UBC Section 2517(f), 8. Hose stations,shall be providedper City Ordinance f1141 tions to ,tfr appeoved by City prior to installation). 9. Ore eNVIO-goirthers shell be provided per NFPA 010 10. All interior wall covering materials shall be fire resistive or shall be treated to be fire resistive, so as to result in a flame speead rating of at least Class III (Class 11 for exitways). Oliver certificAte to th2 Tukwila Fire Department. DATE DRAWN ; CHECK SHEET NO OF SYM REVISION BY APPROVED DATE I SYM REVISION APPROVED DATE (8) D A FACILITIES DEPARTMENT c ) (b) r) \ ViEW — 1ST FLOOR SCALE: 1/16"=1'-0" D AUBURN, WA. 98002 D E.VERETT, WA. 98201 0 KENT, WA. 98031 0 PORTLAND , OR . 97220 D RENTON, WA. 98055 El SEATTLE, WA. 98124 APPROVED BY ACCEPTAB THIS DESIGN S P E C I F I C A T I O N I PROJECT AREA JOB #115093-00 ILITY AND/OR S APPROVED DEPT. DATE DRAWN BY -- TDATE ML SMITH A_ 578-90 (1) ED BY LA-C3F FL PI__A\ vES 1JF SPACES. SEPARATE PERMIT AND APPROVAL REQUIRED. 114 SUBTITLE TITLE F 1 Y tegi elat MailfAtsti ...... ~ • • I understand that the Plan ITher:.:1.. are subject to &Irrors akki onionc- a:x.1 . of 1 Piall'S CkVirg., noti authorize Me yin adt, code or oi koceiot of contrrictors cci)y of approved ptii - wleUged. Date. I- 0-.11 = No....,._ ...... (?...t. SEP r:TY Of FUKWILA APRP.0 BLDG 12•126.1 PLAN V I E W - 1ST FLOOR iM IT MASTER COL A-F/1-14 JOB NO. DWG. NO. LAST REVISION 7 DATE ACCEPTABILITY THIS DESIGN AND/OR OVED SPECIFICAT!ON IS APPR DRAWN BY M.EE 1 D TE 7 4 6 8 SUBTITLE ____ PART I AL F I RST FLOOR PLAN LAST REV!310N SYM F DATE .27.131, _ OF I r trCKED TRINECRED-PY SHEET 1 1 A 1 APPROVED BY DEPT; ATE TITLE ___ _ ARCHITECTURAL MASTER B11)(3. 12-126.1 COL. A-C/1-9 SCR NECTEID P JOB NO. E4 ... APPROVED _ ________L. .._ --1 _... DW DWG. NO . '. 12.126-1A11 D SYM JANITOR WOMEN CO P RO M ST RAGE CONF. ROOM AMA 0 W i-WWW.WEVOMMSW:W.UWWFWAic,awli., ---------- ••■•■•■••■■•••■■••• LUNCH ROOM STORAGE 2'-6" REVISION AJ REVISED ENTRY J W175010-00 AS-BUILT J W794512-00 NAVYFFICFKAW 105020-00 MAIL DCN NETWORK 4704143 SURVEILLER LAB J#704593-00 STORAGE ROOM BY g.COLLINS M.LEE APH STANDAAR DJT B. COLLIN J.TORR 6.COLLINs APH STANDAART KITCHEN APPROVED DATE 4/7/87 STORAGE JW/AB 12/7/89 JW/AB 4-23-90 JW/AB 5/7/90 DJS/AB 11-19-90 SYM E F STORAGE F ACE OF / / WALL 18 -0" r FACE OF WALL--, REVISION FLOOR SINK 4 714131-00 CONSOLIDATE ESD J# 115093-00 D i_ A\ V 1 7 1A/ SCALE: 1/8"-1'-0" • BY NT B. COLLIN MLS B. COLLINS APPROVED DJS/DG/AF DJS/DG/MB --====== DATE 4-5-91 8-15-91 .44144, A500 1 A ■•••••••••••••■••■■•■■••■■■...1. 7/5_771g4 CD (.0 B : j [ o i°gs°1\4441"3"‘1144 FACILITIES DEPARTMENT . . . . • .•. " . . •. . - • . OPEN OFFICE SPACE 0 AUBURN, WA. 98002 El EVERETT, WA. 98201 El KENT, WA. 98031 0 PORTLAND, OR. 97220 Li RENTON, WA. 98055 Cl SEATTLE, WA. 98124 0 le TH3 I/4CH 1 2 ! 3 4 5 6 7 8 9 10 11 WaKftWN 12 NOTE: If the microfilmed document is leas clear than this notice, it is due to the quality of the original document. 0€ 6Z Be LZ 9Z GZ 9Z CZ ZZ 12 0? 6L 9l LI 91 GI M CI t IL ofl 6 R L 9 1 C Z "" 0 11111111 0 11 MIIII 11111 1 111 . 111 01161111111Inhil4h: i llilill10 , 1 1 1!!! 1 1 , 1 1 1 11114111Mlind011ithifill fF=1117--- -0) (F (--; N RAI NOTES 1 RETURN REP LINED DRAWING SHOWING ANY DEVIATION FROM ORIGINAL DESIGN TO D. STANDAART , M/S 89-14, 773-0676. 9'-0" HIGH, g'x 20 GA. STL, SrUD CLOSET ALONGSIDE EXISTING W/ (1) 5 / 6"GWEI EACH SIDE AND (1) 3 /4 1 . 1 x x 8 FIRE RETARDANT PLYWOOD ON ALl INTERIOR WALLS, L > F 2 L INSTALL NEW 37';x20 GA WALL W/ 5/8" (MB TYPE 'X' EACH SIDE FROM CONCRETE FLOOR TO UNDERSIDE OF WOOD TRUSS. PER DETAIL. -Ln 0 0 CONSTRUCTION NOTES 1 EXISTING VANGUARD PARTITION. SEND RE-USABLE MATERIALS TO BOEING AGING WAREHOUSE BUILDING 18-236. PATCH CARPET AS REQUIRED. SEE NOTE - 2 - >RELOCATE EXISTING VANGUARD DOOR. FILL OPENING WITH RE--USED PANELS, TRACK, ETC. 2,11.›-TOUCH-UP PAINT WITH PRESERVATIVE'S "NEW LIGHT STRING" SEMI-GLOSS LATEX. REMOVE ENTIRE CARPET FROM ROOM. USE OLD CARPET TO PATCH CARPET ELSEWHERE IN PROJECT AREA. INSTALL NEW CARPET IN OFFICE TO CLOSELY MATCH OLD CARPET. EXACT MATCH MAY NOT BE POSSIBLE. KCEIVF.D CITY0i AUti 23 PERWCENIER AS 107-Al26-1004-A2 CITY (Jr THROW. • A EP R E D St:E; 0 D!VI,q6Fr IflTr Q9 8 KEY PLAN BLDG. 12-126 SCALE : NONE Al2.126-1A11 s•-• "..111144%,,4, S YM A B C) Uo (2Qd AS—BUILT PROVIDE VENT SYSTEM NAVY OFFICE /LA C DCN NETWORK D SURVE I LER LAB I RE VS ION D9430771 B J# 105020 -00 4704143701 J #704593 --00 __ BY�TAPPROVED ~ DATE SYM TEN ZAK B. COLLIN TORT B.COLLINS APH STANDAART ML JW /AJB 1 - 19 -90 E PJD FOR AJB 12 - -4 -89 JW /AJB 4-23-90 JW /AJB 5/7/90 DS /AJB 11-18-90 s :DART IA REFLECTED CEILING CONSOLIDATE ESD REVISION J#115093-00 MATCH LINE FOR CONTINUATION SEE SH SCALE: 1/8"-l'-0" BY COLLINS APPROVED DATE DJS /DC /MB 3 - - DLA\ ._ 1ST FLOOR FACILITIES DEPARTMENT • [1 AUBURN, WA. 98002 El EV ERE TT, WA. 98201 KENT, WA. 98031 PORTLAND, OR. 97220 D RENTON, WA. 98055 L] SEATTLE , WA . 98124 C2) k: .a 4. . __... �..._... -. �. ,. ... ...— ns....w.....- .o�+ +wur+raxR +.VL+4I I I (I T I T 1 1 I III IIIIIiiIIIIIIIIIIII' ). II�III�IIIIIIIIIIIIIIIIIIIIIIIIIIIJtIIII 'IIII!IIIIIIIIIIIIIIIIIIIIIIII IIIII I�' tIIIIII IIIIIIi (IIIIIIIIIIIIIIIIIIIIIIIIIIII 0 18 TMS INCH 2 : 3 4 5 6 7 8 9 10 11 / awm 12 NOTE: If the micrafilmr:d document is less clear than this notice, it is due to the quality of the original document. 06 6Z 8G GZ 9Z G '72 CZ ZZ lZ nZ 6l 8l Lt 9t St h! sl Zl U ca 6 8 L 9 S � e z L ww 0 Il�li�lllllfil�IiiIIILII�iIIIIIIII� !III III; IIIIfII ►1!!IIIIIII�IIllliiil�IIIIII III I fI I I I IiII,Ii,li{Ilill , illtl 1 I ►► I I I ', III�III I .I 1, II I lilt Ill�llli�.!IIIIIII�IIi 111�11I1 ►IIIIiII�IiII�il�lliliilllll llll1II�I IIIIIIIIIIIIIIII �II f �Ililll I �IIIIIIIII�IIIIIIIILIiII +IIII�IJlllillfillillill IIII) f II I II ED ACCEPTABILITY THIS`DESIGN AND /OR SPECIFICA IS APPROVED APPROVED BY DEPT. CDA DRAWN BY A. HARRY t N I NEf:l BY CR CIETU APPROVED IAPPROVED SPRING CLIP- NO. 12 CA. VERTICAL HANGER WIRE ' CROSS RUNNER -' DATE 1 .1 1 2/ 31 .L0 9 SEISMIC BRACI ET N G DAIL_ � : NONE _.. -.^ �. (STANDARD 4 -WAY SEISMIC SPLAY) SUBTITLE TITLE BOLE) CLIP-' MAIN RUINER - - -- A (RUNNERS AT WAL /1' GEAR.; ;CE ATTACHED Al 1CTARTIT,G CLEARANCE AT CPT'OS'TE 411./ A " C1:17. ADJACENT AALL1111.S (OT A1lAD1JD) TOE CLIP WITH --- MECHANICAL FASTENER - USG INTERIORS VSA AJUSTABLE CCWRESSION POST - -UNDERSIDE OF GRIO STRUCTURE ABOVE. - - SPLAY WIRE SECUREDD TO STRUCTURE I TE CTURAL • RECEIVED CITY or •TI-Jl;4MLA Mit;23 t:.Iz�i PCFTMIT cENTFf BLDG . __12-- 1 COL ._ A -C/1 -9 V FIRST Cs 9 F I RST FL REFLECT CE IL LING PLAN L. EGE V ) 2X4 FLUORESCENT LIGHT F I XTURE RETURN A GR SUPPLY A I R D I FFUSER EXIT L'GHT SPRINKLER HEAD SPEAKER SMOKE DETECTOR GENE SAL 1. L 4 ATE 7--18 UBC STAN DREQUARDS IRAL DEREMENTS /SUSPENDED CEILINGS VERTICAL _ HANGEES: SUSPENSION WIRES NOT SMALLER THAN ;/12 GA. SPACED 4' O.C. ALONG EACH RUNNER. EACH VERTICAL WIRE TO BE ATTACHED TO SUSPENSION MEMBER AND THE SUPPORT ABOVE WITH MINIMUM OF 3 TURNS. WIRES SHALL NOT HANG MORE THAN 1 IN 6 OUT OF PLUM, WIRE SHALL NOT ATTACH TO OR MEND AROUND INTERFERING MATERIALS OR EQUIPMENT. PERIMETER HANGERS: TERMINAL ENDS OF EACH CROSS RUNNER AND MAIN RUNNER SHALL BE SUPPORTED INDEPENDENTLY A MAXIMUM OF 8" FROM EACH WALL OR CEILING DISCONTINUITY OR OTHER APPROVED WALL SUPPORT. LATERAL FORCE BRACING: HORIZONTAL RESTRAINTS SHALL BE FOUR #12 GA. WIRES SECURED TO THE MAIN RUNNER WITHIN 2 OF THE CROSS RUNNER INTER --` SECTION AND SPLAYED 90' FROM EACH OTHER AT AN ANGLE NOT EXCEEDING 45' FROM THE PLANE OF THE CEILING. THESE RESTRAINTS SHALL BE PLACED 12' O.C. IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6' OF EACH WALL. L I G H T I N G FIXTURES: ONLY "INTERMEDIATE AND HEAVY DUTY" CEILING SYSTEMS MAY BE USED FOR SUPPORTING LIGHT FIXTURES. FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED CEILING SYSTEM. THE FIXTURE SHALL BE SECURELY ATTACHED TO CEILING GRID BY USE OF (1): APPROVED CLIPS; (2): FIXTURE MANUFACTURERS INTEGRAL CODE ACCEPTED CLIPS; OR (3): BY 1'` LONG SELF- TAPPING, BUTTON HEAD SCREwS. PNoV i DE MINIMUM UI 'L FAS I ENEKS (ONE IN EACH END OF FIXTURE) OR 4 FASTENERS MAXIMUM. WHEN 'INTERMEDIATE' SYSTEMS ARE USED, #12 GA. HANGERS SHALL BE ATTACHED TO THE GRID - MEMBERS WITHIN 3" OF EACH CORNER OF EACH FIXTURE. WHERE "HEAVY DUTY" SYSTEMS ARE USD, EXTRA HANGERS ARE NOT REQUIRED I F A 48" MODULAR HANGER PATTERN IS FOLLOWED. FIXTURES WEIGHING LESS THAN 56# SHALL. HAVE, IN ADDITION, TWO #12 GA. HANGERS CONNECTED FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE AND MAY BE SLACK. HANG FIXTURES ERS. WEIGHING OVER 56# SHALL RE. SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED MECHANICAL SERVICES: CEILING MOUNTED AIR TERMINALS OR SERVICES WEIGHING LESS THAN 20# SHALL B POSITIVELY ATTACHED TO THE. CEILING SYSTEM. TERMINALS OR SERVICES WEIGHING 20# BUT NOT MORE THAN 56 #, IN ADDITION, TO THE ABOVE, SHALL HAVE 'TWO ##12 GA. HANGERS CONNECTED TO THE TERMINAL OR SERVICE TO THE MA CEILING SYSTEM HANGERS OR STRUCTURE ABOVE AND Y BE SLACK . PARTITIONS: WHERE THE SUSPENDED CEILING SYSTEM IS REQUIRED TO PROVIDE LATERAL SUPPORT FOR PERMANENT CR RELOCATABLE PARTITIONS, THE CONNECTION OF THE PARTITION TO THE CEILING SYSTEM, THE CEILING SYSTEM MEMBERS AND THEIR CONNECTIONS, AND THE LATERAL FORCE BRACING SHALL BE DESIGNED TO SUPPORT THE REACTION FORCE OF THE PARTITION FROM PRESCRIBED LOADS APPLIED •FERPENDICULAR TO THE FACE OF THE PARTITION. ENGINEERING SHALL. •BE REQUIRED TO SUIT INDIVIDUAL PARTITION APPLICATIONS AND SHOWN ON THE APPROVED DRAWINGS. ASTER SCS Y OF 1UIEWl ,A PPR0VED SEP T ,4 _. 0 I i I_ JINt, L11 :1SIOI�l JOB NO. \OYES �o 1A281 KEY PLAN BLDG. 12 -126 SCALt : NONE N ST REVISION "TSYM SHEET OF 8 - -8 -91 AUTOCADI DWG NO. I 12.126-1A281 I Al2.126 -1A281 ACCEPTABILITY _ THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN BY ML SMITH DA) F 05/18/88 SUET I TLE ` Ll_,rOR FLOOR `�— - I . PLAN c I� K APPROVED BY DEPT . ATE NUS fNE.EIZED BY ECKEO TITLE BLDG 12_.126.2 D = � V i _I COI.. VAST E A-- F/1 -14 � -- ._ — " - BSC WPROVED APPROVED SYM REVISION 1 BY APPROVED DATE. SYM REVISION BY APPROVED r DATE 3 J Co ( 1'ROJ i L.00A i I ON JOB #115093-00 3 LA\ VI SCALE: 1/16 " =1 ' - -0" / V7 / 77 7 ------) FACILITIES DEPARTMENT ❑ AUBURN, WA. 98002 Li EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 ❑ SEATTLE, WA. 98124 \UTEL - C C NL_ARG CI FOR \ S= 'AC -S, AN 06 6Z 86 GZ 9Z 5Z 4 7Z c: ZZ lZ OZ 61 81 !t 9l 9l +Il F.t Zi ll �( 6 © L 9 I I I I II I I c t 7 E Z l r 14 0 I Ili► IIIIIIIIIIIIIIIIIIIfII Il IIIllll1IIIIII! I! IIIIIIIIllllllllllllIlllliilllIIIII!!► IIIIIIIrIIIII I!! tIIIIlI1llillillil !tIIIIll1111IIIIIIIIiI{If II,! it luiil! IIiIIIIIIII ,IIIIIIIIIIIIIITII!IIIIIIIIIiii I I !II1I!i III 1 1 I , ►� (111 II i iII I :..I, {IILII It {il {fill IIIIIIiiliLlllln Ililiili�i�Iilfillill {I,,,IIiiI i, IIi) • u A I111I11 1111II11i1 111IIIII1111 11111111111111`iI;LI°i� 11 IIIIIIIIIII (IIIIII 11111111111111111111111 III }IIIII111111III1111 II 1111111111111111111 11111Iii111TI 0 1"43:1464 1 2 3 4 5 6 7 8 9 10 11 " /P ' " 12 NOTE: If the microfilmed document is less clear than this notice, it is duce to the quality of the original document. RECMVED CITY COP i umLA MtJU 2 s 1::a1 PERMITCENTER 08 NO . (2,11 OF TO 1 �i1L APPROVED SCP h5T REVIgION SYM DATE SHEET P vi OF 12 -126,2 PERMIT I C ii � E 1 -203 0- (9 ) OFFICE OPEN OFFICE SPACE OFFICE LOBBY MATCH LINE — FOR CONTINUATION SEE SHT2A10 I-- SYM 1 - --- -- -- REV&ON T BY APPROVED DATE I --- A REV I SED PART I T IONS J #175010-00 B . COLL I NS c M. LEE < • 41 J 4/7/87 B RELOCATE ILS PERSONNEL J #175083•00 A TA * 4/21/87 AS-BU 94- APH I L T J #7512-00 IANDAARI ' JW/AB 12/7/89 I ___C___ INSTALL DOORS Y7046/ fi umAl C/AB 12-17-90 1 c FLOOR S I N K J #714131-00 I_ F. T COL I N D J S/DG/A __ 4-8-91 SYM E MEN OFFICE OFACE OFFICE ( ..0 e. , N s iO e'°'"w44(N N%, - • PA:U 1AL PLAN - 2\D FLOOR SCALE: 1/8 REVISION BY APPROVED CONSOLIDATE [SD #115093-00 rqpiliNs DJ S/DG/MB OFHCE OFFICE ( 5) OFFICE OFFICE OFHCF DATE 8-15-91 / /942 _1/ 71-1--7 4 7-17; 2:27 FACILITIES DEPARTMENT OPEN OFFICE: SPACE 1104 El AUBURN, WA. 98002 [Ti EVERETT, WA. 98201 M KENT, WA. 98031 [I PORTLAND, OR 97220 FA RENTON, WA. 98055 El SEATTLE, WA. 98124 • • 7 ' - , , , ••••• • • • ^ , s notice, it is due to the quality of the original document. -...''''''"""'" 7.;:".•:.;:i.«RI '" Tt.. ri -0" ( LIBRA FY STORAGE ...winamor..... OFFICE ACCEPTAB I L I TY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. _ 0 iim s 3 4 5 6 7 8 9 10 11 4AM/UM/4°ff 12 NOTE: If the microfilmed document is lesd clear than this :}) of.: 6Z 9G 12 9Z GZ 1 7Z CZ ZZ I,Z 0? 6t 9t LI 9t Gt 1 7t CI Zt U ot, 6 8 1, 9 G C I PON Itiillinthillin1111111111111111,161111111016111/111111fhililli111111411161nnliffi DRAWN V. LEE MCCITO JE APPROVED DATE SUBTITLE 0§1 —: • CONSFRUCT 1 ON NOTE.... REMOVE EXISTING VANGUARD PARTITION. PATCH CARPET AS REQUIRED. SEE SHEET 2A10. REPAINT GWB WALL WITH PRESERVATIVE'S "NEW LIGHT STRING" SEMI--GLOSS LATEX. LT RELOCATE f:XISTING CORNER TRIM TO NEW CORNER. REMOVE/RA_OCATE: 7'--O" TALL ()BRIEN PARTITION TO DIMENSION SHOWN. ALL SURPLUS MATERIAL SHALL. BE SENT TO BOEING CO. AGING WAREHOUSE:, BUiLDING 18--236. RELOCATE EXISTING VANGUARD DOOR. INSTALL RE-USE VANGUARD PARTITION AND BLACK TRIM. INSTALL NEW RUBBER BASE TO MATCH EXISTING. INSTALL RELOCATED VANGUARD DOOR. RECENF:D. CITY 01: •UKWILA A0(3 2 3 Ib'j PERMIT CENTER 2A10 ARCH TECTURAL MASTER LA - Q 5 ) -0 KEY PN BLDG. 12-126 — SCALE : PARTIAL PLAN — 2ND FLOOR TITLE BLDG. 12126.2 COL. A—C/1-9 SC WAS 107-Al26-1004-A3 13ITY 0 U TUK AP Pf D SEP 1.0 1 • TAM REVISION 7g SHEET 2A 1 UOB NO. DWG. NO . DATE 1 OF E4-151 12.126-2A11 Al2.126-2A11 j partial reflected ceiling sesimic notes lighting plan power first floor electrical master power plan lighting plan construction notes electrical master first floor plan detail . . . first floor plan . second floor piping automatic sprinkler first floor piping