Loading...
HomeMy WebLinkAboutPermit 6808 - Southcentert Mall - Oak Tree - Wall and Door6808 91-416 oak tree 650 southcenter mall Permit 6808 - Oak Tree TYPE OF CONST.: II -N UBC EDITION (year) 1988 SETBACKS: N - S - E- W- FIRE PROTECTION: ®Sprinklers Q Detectors O N/A UTILITY PERMITS REQUIRED? ❑Yes 0 No BAR /LAND USE CONDITIONS? ❑ Yes t publicWorko 0 No ZONING: CONDITIONS (other than those noted on or attached to permit/plans) WA. ST. CONTRACTOR'S LICENSE # ALGENC *306BE EXP. DATE 11 -01 -91 ARCHITECT PHONE PR•P R • NER Jacobs Visconsi Jacobs PHONE 216 -892 -2308 ADDRESS 25425 Center Ride Road, Cleveland, OH ZP 44145 CONTRACTOR A1•ene Construction Com.an Inc. PHONE 774 -3115 ADDRESS P.O. Box 1353 L nnwood WA 7JP 98046 WA. ST. CONTRACTOR'S LICENSE # ALGENC *306BE EXP. DATE 11 -01 -91 ARCHITECT PHONE CITY OF TUKWILA Dept. of Community Development- Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDING PERMIT NO. DATE ISSUED: \ SITE ADDRESS 650 Southcenter. Nail PROJECT NAME/TENANT Oak Tree SUITE # VALUE OF CONSTRUCT - $ 950.00 ASSESSOR ACCOUNT # 262304- 9023 -03 TYPE OF ❑ New Building U Addition U Tenant Improvement (commercial) U Demolition (building) U Grading/Fill WORK: 0 Rack Storage ❑ Reroof ❑ Remodel (residential) ❑ Other: DESCRIBE WORK TO BE DONE: Add approximately 18 linear feet of wall and one 20 minute door for office. ADDRESS CODE.; *,COMPLIANCE: : FLOOR SQUARE FEET SIGNATURE OCCUPANCY NO. OCC. LOAD SQUARE FEET OCC. SQUARE LOAD FEET PRINT NAME: / / /i LET �'- 7 ( A r a ri lVi f I (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) FEES DESCRIPTION B.UILDING;PERMIT FEE PLAN;:CHECK <FEE .:.' BUILD.ING:SURCHARGE' O. E TOT `AMOUNT RCPT: :# >:DAT 260;7 PLAN CHECK NO.: 91 -416 OCC. LOAD SQUARE OCC. FEET LOAD BUILDING OFFICIAL COMPANY SQUARE FEET DATE: OCC. LOAD APPROVED FOR ISSUANCE BY: o ZIP TOTAL SQUARE FEEL TOTAL OCC. LOAD I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of lay and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. DATE: ( /t " C � 1 t r r C o-V, ��kiee J? ' A .. ssu nce / or f the works suspended or abandoned for a pe od o f 180 om hef las lnsectror CERTIFICATE OF DATE ISSUED: PERMIT NO. CONTACTED N\ DATE READY DATE NOTIFIED fry l r CO BY: ` PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING + 3RD NOTIFICATION BY: C BUILDING PERMIT APPLICATION TRACKING L PLAN CHECK NUMBER L d1H LI(tO INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) SQUARE OCC. FEET LOAD SQUARE FEET OCC. LOAD SQUARE OCC. FEET LOAD SQUARE OCC. FEET LOAD SQUARE OCC. FEET LOAD TOTAL SQUARE FEET DEPARTMENTAL REVIEW "X" in box Indicates which departments need to review the project. HOV 2? 4 ROUTED) DEPT. LETTER DATED: UIREME Sprinklers Detectors (1 N/A 9- 3 -•'9) INSPECTOR: !'i s PA t TIME BUILDING - (1--Qi initial review FIRE O PLANNING O PUBLIC WORKS O OTHER PROJECT NAME OoK l .ems SITE ADDRESS (D50 53V- nt-er Pak11 ,� FIRE PROTECTION: � NI l FIRE ZONING: INIT: /V4 INIT: INIT: CONSULTANT: Date Sent - Date Approved - REFERENCE FILE NOS.: MINIMUM SETBACKS: N- s- UTILITY PERMITS REQUIRED? ( ) Yes PUBLIC WORKS LETTER DATED: BUILDING - ( In/ ll� tb 41 final review �' "( INIT: J-►-- 1 v / REVIEW COMPLETED SUITE NO. M E . — jBAR/LAND USE CONDITIONS? ( UBC EDITION (year): TOTAL OCC LOAD Yes No 08117 SITE ADDRESS SUITE # 644 650 Southcenter Shopping Center VALUE OF CONSTRUCTION - $950.00 PROJECT NAME/TENANT Oak Tree ASSESSOR ACCOUNT # 262304902303 (commercial) Li Demolition (building) 0 Other: TYPE OF 0 New Building Li Addition 1) Tenant Improvement WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) DESCRIBE WORK TO BE DONE: Add approximately 18 lin. ft of wall and one 20 minute door for office BUILDING USE (office, warehouse, etc.) Retail Sales NATURE OF BUSINESS: Mans Clothing Store WILL THERE BE A CHANGE IN USE? (] No 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: Tenant Space: 2726 Area of Construction: 72 sq. ft. WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? ® No D Yes IF YES, EXPLAIN: PROPERTY OWNER J.V.J. Dana Paul PH O NE (216) 892 -2308 ADDRESS 25425 Center Ridge Road; Cleveland, Ohio ZIP 44145 CONTRACTOR Algene Construction Company, Inc. PHONE (206) 774 -3115 ADDRESS P.O. Box 1353; Lynnwood, WA ZIP 98046 WA. ST. CONTRACTOR'S LICENSE # AL- GE- NC *306BE EXP. DATE 11/01/91 ARCHITECT PHONE ADDRESS ZIP CITY OF TUKWILA Department of Community Development - Building 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK (� _ NUMBER �l L L BUILDING OWNER OR AUTHORIZED AGENT CONTACT PERSON DATE APPLICATION ACCEPTED Qi - a6 - PRINT NAME Gene Hagen ADDRESS P.Q. Box 1353 Albert C. Tutt BU1LDIF3 PERMIT APPLICATION Division DESCRIPTION BUILDING PERMIT FEE PLAN CHECK FEE BUILDING SURCHARGE OTHER: • 1 HEREBYERT.IFY.;THAT 1 >HAVE,`READAND: :EXAMINED THIS APPLICATION ;AND KNOW BE TRUE AND .CORRECT, AND l AAM : AUTHORIZED ;;TO' APPLY : F.OR .THIS: PERMIT SIGNATURE AMOUNT • 05.0 W;t 1ti TOTAL LLB: JO' . DATE DATE APPLICATION EXPIRES RCPT # O THE: :;DATE PHONE(206) 774 -3115 CITY/ZIP Lynnwood, WA 98046 PHONE(206) 774 -3115 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. COMMERCIAL ---- -- one for entire project) NEW COMMERCIAL BUILDINGS /ADDITIONS Completed building permit application (one for each structure) Assessor Account Number Two sets (2) of the following: Specifications ri Structural calculations stamped by a Washington State licensed Soils report stamped by a Washington State licensed engineer;; Topographical survey Energy calculations stamped by a Washington State licensed engineer. or architecf Legal description' Working drawings, stamped by, a Washington State licensed architect, which include: • Site plan • Architectural drawings • Structural drawings ••:Mechanical drawings.: • : Elevations •.Civil :drawings Landscapo Plan: Completed .utility : permit application ri Six (6) sets of civil drawings NOTE utility permit application and checklist for specific Dili submittal requirements RESIDENTIAL: REMODELS Completed building permit application:(one for each Assessor Account Number o (2) sets of working ; drawings, which include •`Site plan •`Foundation plan • Floor plan Roof`plan •Building;elevations (all views) Building cross.section . framing plans NOTE I/ any utility work Is to be done provide utility permit application and plans must be submitted RACK STORAGE: Li Completed building permit application Assessor Account Number::.: Two (2) sets of plans, which include: Bulldingfloor plan showing: • Entire space where racks will be located • Exit doors.' • Dimensions of all aisles ri Tenant space floor plan showing rack storage layout, aisles and exits NOTE: include dimensions of racks (height, width and length), aisles and e.;it ways on plan. n Structural calculations stamped by e Washington State licensed engineer (rack' storage 8' and over). • RESIDENTIAL NEW SINGLE.FAMILY DWELLINGS /ADDITIONS 1 - :1 Completed building permit application (one for each structure) Legal description; Assessor Account Number Two sots (2) of.working drawings, which include. Site plan •—•41. (On plan, show closest hydrant location: • Foundation plan Include access to building, showing • Floor plan • width and length: of access.) • Roof plan j Building elevations: (all views Building cross- section • • :Structural framing plans 11 Washington State Energy. Code data Completed utility permit application Six (6) sets of site plans showing utilities SU BMITTAL CHECKLIST NOTE: Building site plan And utility site plan May be combined. See utility permit application and checklist for specific submittal requirements,; Additional topographical and soils information may be required if unique site conditions. OMM ERCIALTENANT. IMPROVEMENTS. Completed building permit application (one for each structure;. tenant) .: Assessor Account Number k'i Two (2) sets of construction plans, which include; • Site plan •. ; Existingend proposed parking • Landscape plan.(if applicable, i e , change of use; Overall, building plan • Tenant location Use of adjacent (common wall) tenant `..Overall dimensions of building or footage Floor plan of .proposed tenant space '' Location of tenant •;Tenant space plan with use of each room labelled •: Exit doors;; n egress: patterns. New walls, existig wall, and walls to be demolished. Construction details . • Cross sections showing wall constructfonand method of attachment,for floor and ceiling : — uural calculations stamped bya Washington. State licensed • e may be required if structural work done`(2 sets), . NOTE•:.If any utility work /s to' be done, submit;separate ubllty permit application and ans. REROOF Compl building permit application (one for, each structure Assessor. Account Number Narrative describing existing roof, material being removed,: an 'material being installed NOTE :A certification letter: is required prior to final inspection nand si, off of the permit ANTENNA/SATELLITE DISHES Completed building permit application' Assessor Account Number Two (2) sets Of plans, which include Site Plan (showing building and location of antenna/satellite Details antenna/satellite dish and method of :attachment` Structural calculations stamped by a Washington State license engineer may be required • REROOFS Completed building permit application;( one for each Assessor Account Number Narrative describing existing roof, material being removed, an material being Installed NOTE: A certification letter is required prior to final Inspection and sign - B4OE ®/9/!s 1916 1991: A HS December 3, 1991 L- 6210- TLB -91 -247 Boeing Defense & Space Group Military Airplanes Division P.O. Box 3707 Seattle, WA 98124 -2207 Mr. Ken Nelsen, Plans Examiner City of Tukwila 6200 Southcenter Boulevard Tukwila, WA 98188 Subject: Revisions to North Access Control Lobby Requested by Boeing Fire Protection - Discussed with Bob Benedicto by Stan Cruse, BECE, in your absence on 11/91/91 Reference: Building No. 9-08.2, Phase 4 Plan Check No. 91 -365 Dear Mr. Nelsen: As discussed with Bob Benedicto, Brian Bailey of Boeing Fire Protection Engineering requested we revise our existing building plans to include an opening from Access Control Lobby (255) gaining access to Stair No. 5 (244) in an emergency condition when elevators are called to the second floor when smoke is detected on the first floor. Existing security design only allowed exiting through the first floor smoke condition area. Bob Benedicto indicated that because we have a lobby condition with walls surrounding it of one hour construction, that the proposed opening would be acceptable. Please call if you have any further questions. Sincerely, BOEING DEFENSE SP CE GROUP T. L. Bennett L -6210 46 -87 544 -2975 Enclosure: Revised and new sheets A -11, 11A, 26B, 45 licerivED CITY OF'iIJI:W L A DEC 9 Mil pauvi T CENTER DATE (206) 433 -1851 CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * *REVISION SUBMITTAL ** PROJECT NAME ADDRESS CONTACT PERSON ARCHITECT OR ENGINEER PERMIT NUMBER 6CJ.o , — (If previously issued) PLAN CHECK NUMBER 9/ TYPE OF REVISION: SUBMITTED TOs PHONE ..".�7 4-r SHEET NUMBER (S) "'/ / ;)-4. �/ "Cloud" 9,1;. or highlig t eas cif revisi s and date revisions. 'roe : O a h� t�e. YP:: ...(� `' Address; � � (� - ; - --. =--- - ( b- f / Special Instructions: A.o (0 :oa. Am'1¢ �� Date Wanted: 10' l $ " 1i am p.m. Requester: /^� ��� ` .... 771 Phone No.: I_ 3 1 i s k Approved per applicable codes. IN ���TION ReCOFib .::t.' Retain a copy with permit CITY OF(TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Date: PERMIT No. v (206) 431 -3670 0 Corrections required prior to approval. COMMENTS: 0 . $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PROJECT: (144t- `7 -E8 PERMIT NO. (p O8 SITE ADDRESS: 660 .5. C. /A4.1. DATE CALLED: /0 el5 ._cif' TYPE OF INSPECTION: - Ia-rv. ,I0' / 62L,/se. DATE WANTED: /a .1c- Q a.m. SPECIAL INSTRUCTIONS: „Q.q, REQUESTER: . �•.2c..u.-._ PHONE NO.: INSPECTION RESULTS /COMMENTS: INSPECTOR: ( , (--- DATE: 1 0 - 15 *- \ CITY OF TUKWILA Dept. of Community Development - Building Division Phone: (206) 431 -3670 INSPECTION RECORD 6300 Southoenter Boulevard — #100 Tukwila Washington 98188 FINALAPP.FRM City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Project Name O fri t' Address 6 „ss..a A-4 ..� _ Needs shift inspection TURWILA FIRE DEPARTMENT FINAL APPROVAL FORM it r /Retain current inspection schedule Approved without correction notice _ Approved with correction notice issued Sprinklers: Fire Alarm: �7 Hood & Duct: /`� Halon: Monitor: Pre -Fire: A9, Permits: Authorized Signature Date Gary L. VanDusen, Mayor Control No. //-97 Permit No. /W(? l Suite # T.F.D. Form F.P. 85 `"' l; .rt7 p fe : 1Y'Sf� STS! 1577 • • FOOD COURT • • .16 3311: x A =1. E ® NOAH'S ►t1 ^ LLL R ! r Deer ' POitOt F . , IT t .>L VI. nrf.rDv$ NORDSTROM THREE LEVELS t_ s i . 3.1 0 17t til O .1.,I7 •E •, I 101.11 L.R• 1u I NOtO CO.CtI'1T '41-71 0111,41, 'I .L kIS 3 fcl ' 1.1"--" 1.1"--" S, 5 1 : in L AMt ,F. • A .i F 73'3!1 1a1,11 1[S Jr- •„A .1 a 01Va y] FREDERICK NELSON THREE LEVELS r'• 19. S,:OC41,4411 e 6 Ls (o %b% gI E C E j tl DI i (EI W 1 C GAG? DRUZ. • Lrrt hr.•L 541$ L S uta w0.umo E G nl NOSIO / S —r LI I 1 7; il 11 illi, snif +pA� _ H r �� 1 16' 120 ltl1NNi s= tII I , 1 y u u 1 t ® r "._ —"'� "� s El ^� ...nriNL>.. �- I , RI •; - •r etextM aura 11 RI . yar•p..k vir. 3 1 Y 1. IN ® Mt ./.1.1(2 C!I •" 'j COC >•, ` .'� ® ese ® q , e II 67[ ' f--- . ... 4 0 7 ti 71 7 R .0 k ' 1 uet u, tI. El II 1197A r S10NACE 53115 RI DOUG rot MAxt1 THE BON FOUR LEVELS 1, . t ENIR*NC5 :. �� , L.DMA 1.0.601 -J J at ri • A A .16 0 4k 7i'5E A24 S��i ce G 5f4? Ass CZ 3 ° ?a12303 ¢ I 6 lc., At 3. J tm[CIAl1ONS at 1 C tl DC RI 573 573 uat.S.M1M k Kit fllGt , [MA , HIAOSMOTS N. 1 C STD 1 l 272 .RUI S NpLAss .71 V 1n C LUE Od ENMRONCE ,ppNN ' "U-112 vt.tu. ENIR*JICE toll .111.4. 32,.6 T06. • E OTHER STOR THE BON FOUR LEVELS Sewer; 144.3.6 89111 RICCA CITY OF TUKWILA 6200 SOUTIICENTER BOULEVARD, TUKWILA, WASHINGTON 98188 Plan Check #91 -416: Oak • Tree 650 Southcenter Mall PHONE II (206) 433.1800 THE FOLLOWING COMMENTS APPLY TO AND BECOME PART OF THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER %0) 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (872- 6363). 3. All mechanical work shall be under separate permit through the City of Tukwila. 4. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 5. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 6. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 7. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 8. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1991 Edition), and Washington State Regulations for Barrier Free Facility (1989 Edition). 9. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. Gary L. VanDasen, Mayor "X" REQUIRED INSPECTIONS PHONE DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 g 7 Framing 431 -3670 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 , X 10 Wall Board Fastening . 431 -3670 11 12 . 13 X 14 FiRE FINAL Insp: 575 -4407 15 PLANNING FINAL 431 -3670 16 PUBLIC WORKS FINAL 431 -3670 X 17 BUILDING FINAL 431 -3670 CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: 650 Southcenter Mall BUILDING PERMIT INSPECTION RECORD (Post with Building Permit in conspicuous place) SUITE NO : BUILDING (.0(E0 PERMIT NO. DATE ISSUED: PROJECT: Oak Tree CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (INSPECTOR COMMENT SECTION ON REVERSE) INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping Is in place. 8. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department — 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the project progresses. 09114190 PLAN REVIEW COMMENTS r Plan Check No.:9 X ` 11I Project: C7A rD No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. REQUIRED INSPECTIONS 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). 0 Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277 - 7272). 0 All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building Inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special Inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high - strength bolting to be special Inspected (Sec. 306, UBC). OD Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14 Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final Inspection (see attached procedure). 7. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. 0 Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. 1. Footings 2. Foundation 3. Slab/Slab Insulation 4. Shear Wall Nailing 5. Roof Sheathing Nailing 6. Masonry Chimney 7. Framing 8. Insulation 9. Suspended Ceiling V 10. Waii Board Fastening 11. 12. 13. 14. Fire Final 15. Planning Final 16. Public Works Final 17. Building Final PLAN REVIEW COMMENTS r Plan Check No.:9 X ` 11I Project: C7A rD No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. REQUIRED INSPECTIONS 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). 0 Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be inspected by that agency (277 - 7272). 0 All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building Inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. 7. All structural concrete to be special Inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high - strength bolting to be special Inspected (Sec. 306, UBC). OD Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14 Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 15. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report prior to final inspection (see attached procedure). 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final Inspection (see attached procedure). 7. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washington State Energy Code (1990 Edition), and Washington State Regulations for Barrier Free Facility (1990 Edition). 18. All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. 0 Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575-4404 Fire Department Review Control #91 -416 (513) Re: Oak Tree - 650 Southcenter Mall Dear Sir: October 1, 1991 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. 2. Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 10.402(a). Exit doors shall be openable from the inside without . the use of a key or any special knowledge or effort. (UFC 12.104b) No obstruction or storage shall be placed in the required width of an exit except for projections permitted by the Building Code. (UFC 12.103a) Gary L. VanDusen, Mayor 3. Maintain sprinkler protection for all enclosed areas. (NFPA 13, 4- 1.1.1) (UFC 10.302) All sprinkler drawings shall be prepared by companies licensed to perform this type of work. Drawings shall . first be approved by the Washington Survey & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1528 & NFPA 13, 1 -9.1) (UFC 10.305) 4. All required occupancy separations, area separation walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when Page number 2 City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206)575 -4404 damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) Gary L. VanDusen, Mayor Walls and ceilings of corridors serving an occupant load of 30 or more shall be not less than one -hour fire resistive construction. (UBC 3305(g)) (UFC 12.105(a)) All interior wall covering materials shall be fire- resistive or shall be treated to be fire-resistive, so as to result in a flame- spread rating as required by UFC Appendix VI -C tables 42A and 42B. A certificate of the flame spread rating is required to be delivered to the Tukwila Fire Department. (UBC 4204) (UFC 10.401) Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd CITY OF TUKWILA Department of Community Development - Building Division Phone: (206) 431 -3670 OCCUPANCY GROUP TYPE OF CONSTRUCTION LOCATION ON PROPERTY BUILDING HEIGHT /# OF STORIES , FLOOR AREA APZA t.3arK a 1 4 OCCUPANT LOAD 4-1:a o r. -s-T 1' -v�E e. EXITING REQUIREMENTS DETAILED REQUIREMENTS OCCUPANCY TYPE OF CONSTRUCTION PART V, CHAPTER 23, U.B.C. W.S.E.C. CHAPTER 51 -10, W.A.C. NOTES PREPARED BY: PLAN REVIEW DAV- 7 5o csoo-r4 ce.).-cst›..._ MALL_ ctet A emi PLAN CHECK NUMBER RI-L-116 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 DATE' ALGENE cotintaucTios FILE COPT heck approvals are i u bj e t tend that the Plan ss omissions and apP any subject t' errors and vlolatfon ei plans` does not authorize the Receipt. of con`'. code 'or ordinance. Receipt e ao f con adopted of a pproved plans