Loading...
HomeMy WebLinkAboutPermit D01-024 - CASH AND CARRY - RACK STORAGEs..,.t."4.Xvkftiz.ta CASH & CARRY 230 ANDOVER PARK EAST EXPIRED 1-20-02 D01-024 City of Tukwila Community Development / Public Works • 6.300 Southcenter Boulevard, Suite 100 • Tukwila, Washing ton ti8188 Parcel No: 022310 -0100 Address: 230 ANDOVER PK E Suite No: Location: Category: ARET Type: DEVPERM Zoning: TUC Const Type: Gas /Elec.: Units: 001 Setbacks: North: .0 South: .0 Water: N/A Sewer: N/A Wetlands: Slopes: N Contractor License No: OCCUPANT CASH & CARRY 230 ANDOVER PK E, TUKWILA, WA 98188 ROSELLINI ALBERT D 5936 6TH AVE S, SEATTLE WA 98108 PAUL DEEMS 1807 132 AV NE #2, BELLEVUE, WA 98005 RBI CONSTRUCTION 1807 132ND AVE #2, BELLEVUE WA 98005 ***************************************************** * * * *k* * * * * * * * * * * * * * *k * * * * * * *k ** Permit Description: REPLACE EXISTING RACK STORAGE WITH NEW 94" TALL RACK STORAGE. ************************************************ k**** * * ** * * * * * * * * * * * * *k **k * * * * * * * *** Construction Valuation: $ .00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N OWNER CONTACT CONTRACTOR WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES. APPLICANT IS PROCEEDING AT THEIR OWN RISK. Hauling: Land Altering: Landscape Irrigation: Moving Oversized Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: N Private: N Public: N * * * * * * * ** * * * * * * * * * * * * * * * * * * ** tilt****************** *** * * * * * * ** * * * * * ** * * * * ** ** * * * ** *k* TOTAL DEVELOPMENT PERMIT FEES: $ 900.0 **** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** *************\ * * * * * * * * * ** * * * * * * * * * * * * * * * * ** ** z) L Permit Center Authorized Signature : �s.-✓ I hereby certify that I have read d examined his perm, i' and know the same to be true and correct. All pro sions of law nd ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. Signature: Date: ' 2o' Print Name: __Zo 6 1 i%77cJ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. DEVELOPMENT PERMIT N No: N Private: N N N Permit No: Status: Issued: Expires: Occupancy: STORE UBC: 1997 Fire Protection: AUTO FIRE ALARM East: .0 West: .0 Streams: Phone: Phone: 425 - 881 -1985 N Start Time: End Time: N Cut: Fill: N N Start Time: End Time: Phone: 425 -881 -1985 Date: (206) 431 -3670 DO1 -024 ISSUED 02/12/2001 08/11/2001 Public: N ; CITY OF TUi',W1LA Address: 230 ANDOVER Ft F Ferwir Uo: U01-0:24 Suite: Tenant: Statue: Type: DEVPERM Auplied: ( Parcel #: 022310-0100 id: 0,'ile/20w k . A . A . 1 1 * A * * * 1 * * A e b A t k W A , A A • k i t i - A 4 . * * 1 A A * 4 . A * 4 A 44A 4 44 440 4 4 A * A.A 4 A A 4 4, F.) 2 • o co 0 • u, L .S 1 • is u o < 22a z F kcz.? u. c.) 1 Permit Conditions: 1. No changes will be made to the plans uniees approved by the Engineer and the Tukwila Building Division. 2, All construction to be done in conformance with approved plans and requirements of the Uniform Building Gu&. (1 Edition) as amended. Uniform Mechanical (.ode (1997 Fditioo). and Washington State Energy Code (1997 Edition). 3. Validity of Permit. The issuance o a permit or approeal of plans. specification. anti computations shall not be con- strued to be a permit for or an apprcival of. any violation of any of the provisions of the building code or of anv other ordinance of the jurisdiction. No permit pre..iuming to give authority to violate or cancel the proviJ,ion5 of this code shall be valid. 4. All permits, inspection recori s. and aubroved plan shall be available at the job site prior to the start of :inv con- struction. These documents are to be maintainel and avail- able until final inspection approval is g(anted. 5. **AFIRE DEPARTMENT CONDITIONS 6. The attached set of plans have been reviewed by ihe Fire Prevention Bureau and are acceptable with the followiog concerns: 7. Storage may not be closer than 36 inches in all directions to ceiling "Space or Unit" heater'.,. (UFC 1109.2 6. Storage may not be closer than 18 inche., below :,prinkler heads, (NFPA 13. 4-2.5) 9. In double row racks with heights of storage up tc and including 25', an average nominal 6" transverse t :.■)3C.4: between loads or at rack uprights shall be maintained. (NFPA 13) 10. Maintain minimum 6" longitudinal flue space between back to back racks. iNFPA 13) 11. Where storage he exceed . s 15 feet and celling sprinklers only are installed, fire protection by one of followjn9 methods is required for steel buildiny columns located within racks: (a) one-hour fire peoofing, (b) sidewall sprinklers at the 15 foot elevation of the column. tc) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 131 12. Aisles leading to required exits shall bc provided from all portions of buildings. Aisles located wit.hin an accessible route of travel s,hall also comply with the Buildino Code requirements for accessibility. (UFC 1204.1) 13. Depending on the classification of the commodity being stored and the size of the storage area. smoi.e vents. small hose stations and curtain boards may be required by Table 81-A of the Uniform Fire Code. Contact the Tukwila Fire Prevention Bureau for further inFormation. ar 1 4 . An approved hose sta.tion requires plans r e v i e w r P i : ns must be submitt.ecl the Fire Marshal for a pr .i prioe to installation.) cCity Ordinance #1901) 1 5 . Racks designed for high-piled storage must comply w i t h section 2207 of the Uniform Building Code. Please coat iu . the Tukwila Building (Department for details. pertaining to design and installation standards. 16. Refrain from blocking sprinkler coverage with shelving. NFPA standard #13 _ t.ate_ that any shelving ter decks in excess of 4 feet i n width w i l l require installation of sprinklers thereunder. 17. High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height oyr combustible materials on pallets - or in racks more than 12 feet in height. For certain special-hazard and cronrmodit ies such as rubber tires, plastics. some flammable liquids.. idle pallets. etc., the critical pile height may be as low as 6 feet. (UFC article 2, sec.. 209 -H) 18. Contact. the Tukwila Fire Prevention Bureau to witness all required inspections and t e s t s . (UFC 10.503) ( C i t y Ordinance #1900 and #1901) 1 9 . This review l i m i t e d to speculative tenant sc►a+:e o n l y - special f i r e permits may be necessary depending on detailed description of intended use. . Any overlooked hazardous condition and /or violation of the adopted F i r e or B u i l d i n g Codes doe a. not i m p l y apprclval of such condition or violation. . The plans were reviewed by _512_. If you have any questions, please call the Tukwila Fire Pr event ion Bureau at (206)575 -4407. I hereby certify that. I have read these Conti i t. ion: a n . i w i l l comply with them as outlined. A l l p r o v i s i o n s of law and ordinance govern ; rru this work wi11 be complied with, whether _:peg_ if ied herein in or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of arty other work or local laws regulating construction or the performance of work. 5 igrrature: Print Name: 14-4.4 /4.0c /d 4 '~ '7 Date: Project Nament: � �� Value of Construction: �f i] b ` � j T Site Address (include City ude suite numb r) _ Cit St ti • -? r7 f+A)rf,rTi _.K . C- . To t)t Lr{ 9 , & Tax Parc l t73 ( D —01(V , Phone: Property Owner: '. Street Address: - Cit t at p: (cola 0_ 1-1--,4.8 - tom. Cur tc C:DMM xe o c .0A Db O Fax #: — Contractor. . .r4,L:; ,.AJ 3 . Phone: 4Z5-Ut- (9n`'3 Street Address: City State/Zip: (`co 7 1 Amts'- = z- "e:�-,..cF.ahte- tA.)- i' ' c cS Fax #: 0 z.3 : ( - &;9 75' , Architect: c GZT e' Nik L- Phone: /�� - Street Address: City State/Zip: Fax #: / Engineer: 5So - t4 - r - C'A16 11v0 - - �, Phone: 3 ._ 'A-5- - RID I Street Address: I , City State/Zip: /ace, 9 " 111 CI- 1 cSr✓ - A : U r CA 90c3A Fax #: Contact Person: p � ) t `t:' - ''L S 1` � _- e S i f').JL -Tt t-1 Phone: q - _ - { - (9 tg.s Street Address: City State/Zip: 180 z P — ° A,�� z ? ,,,d rut `� Zm . Fax #: 7 S d 1 �9 . Description of work to 1 ZETuAC be done (please be specific): e t S -r .✓Z� • A-- - 7 - - n2r -, €. '.e1 AI C- u--1 ( '' 7A LL f� "/" eS�: -.t: Existing use: ►: : etail ❑ Restaurant Church ❑ Manufacturing ❑ School /College/University ❑ Multi - family ❑ Warehouse ❑ Hospital ❑ Motel /Hotel ❑ Office ❑ Other ❑ Multi- fami ❑ Warehouse ❑ Hospital ❑ Motel /Hotel ❑ Office ❑ Other Proposed use: Retail ❑ es auR rant ❑ Church ❑ Manufacturing ❑ School /College/University Building Square Feet: . 14 Soo ` existing No. of Stories: , Area f construction (sq ft): Will there be a change of use? ❑ no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ no Existing fire protection features: ��►2�s V automatic fire alarm ,none ❑ other (specify) Will there be storage of flammable/combustible Attach list of materials and storage hazardous material in the building? ❑ yes no location on separate 8 1/2 X 11 paper indicating quantities & Material Safety ata Sheets Date application accepted: 11/30/00 clpermit.doc CITY OF T UJK' "ILA Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE /CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization/Striping ❑ Curb cut/Access/Sidewalk ❑ Flood Control Zone ❑ Hauling ❑ Fire Loop/Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cu cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application expires: - 7 Project Number: Permit Number: D PLEASE SIGN BACK OF APPLICATION. FORM z w ce J U O 0 U) 0 • W J H W O 2 L Q co � z � z W U O - O W W u. H � lll co HZ O z Fir rata eel r ow. rimos • _v ... Tamaj BUILDING OW :R OR AUTHORIZED AGENT: Date: it\ q 'T Signat '-' rte Print name: iVG /k ( I l f 2 0 r Phone 2 /c-,. -7 // Fax #: - „i, `,� v 71 Address 0 1 7 7 ( t ( Q( t' 1 City/State/Zip e )' ni et' : - ' C APPLICATI MUST BE SUBMITTED WITH TH • [LOWING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing/grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H -9). Z W 6 J U UO to (n w = ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled W Lu LL ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of w any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site to Cy = w t- - = z � I- O Z U p O N a t- w H - LLO w Z v= 1 o „- O z ack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 999 Third Avenue, Suite 700, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form 11 -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT i HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERI )LY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 11130/00 dpermitdoc A ******************AA 4,A A** ****0 A*** A** A r r A AA AO A f ***A f fr f rr *I 1:1r7 OF fl;KNILA. ** Or* *Or* t A.*** * ** **ft r AO** t ;PR #F*. A*A #A 40.**AOF 1 f ruoimir Nomoor: R01 iloodot: 4 : Pi(vment Method: Ooti ion: Permit 0o: D0.1-24 lvoe: tiEVELC:!mE01 PLFhll Parcel No: 02:2310-0100 bite AddreEsn 230 OODOVEP Ph U Th 1 Pi‘vhent t547.25 rot:1i 10i ALL Account Code Ocr lot 000132 bUlLDINC - NOOFE 000/306.' rrE OUILDCW: 1. Y., TOTii - L.. IVIW oT.LL• f:314000 - AAH.) Ntlid 0C3*qt uo140ta, i 4uno330 4#44A1****-0#4w44v4v*441 10:)ko I !! fl t)!4 ..!s:,i)0 )v40 4 14 4 W. 4 ) q! , j 4300(MH 1.1saJppil ,9411 00'10 -".°N LAROJ ij 4 •13J030 ';' 017;')-TOU : :3 3 111 u 4 0 0 H P '4 4 t4 4 I • 1 i I ° A q 1 c G ' qn001(01 :aaquIIN n •triminl :1( 411:1 4 # 4 4 4 4 4 . 4 4 4 • Y. V 4 4 '4 4 f f 1 4 * 4 4 & 4 4 4 4 4 4 4 4 4 4 kg 4 4 it 4 4 It * Proje : }} 1.1 e _ ti .:-- C 6 d7+' Type of Ins e 7 on: ) ''''74 / ,4't e-e Ad ress: IA Date called: 223 -0 °;.211. Special instruction : Date wanted. Requester: Phone: _ '- "r'�� �E INSPECTION NO. Approved per applicable codes. COMMENTS: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 - 3670 3 441 of 'LCorrections required prior to approval. Inspector: "K/ dA 1 .1 Date: El I $47. ► I REINSPECTION F REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Project Name Address Fire Department Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: . , \ ' Authorized Signature FINALAPP.FRM , City of Tukwila TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Rev. 2/19/98 Steven M. Mullet, Mayor Thomas P. Keefe, Fire Chief Permit No. (..)\ —C Suite # 17\0 Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 RECEIVED CITY OF TUKWILA 'ERMi1 CENTEF, STRUCTURAL CALCULATION FOR STORAGE RACKS AT SMART AND FINAL 230 ANDOVER PARKEAST TUKWILA, WASHINGTON el %0 2 01001 AuC Advanced Technical Consulting P.O.Box 1963 San Ramon, California, 94583 Tel: (510) 796 -4411 Fax: (510) 796 -4412 Job Number 0101 -11792 Revision 0 January 2001 ti Total Pages) K: biz Mo : •. • ani Ci : eer No. 0029579 Expiration Date: 9/13/01 of -o24 Coversheet Table of Contents 1.0 Purpose 2,0 Refernces 3.0 Rack Profile 4.0 Design Criteria 0 KM Attachments 1/16/01 REV BY DATE Advanced Technical Consulting 4.1 Seismic Loads 4.2 Load Beams 4.3 Columns 4.4 Bracing 4.5 Connectors 4.6 Base Plate & Anchor Bolts 4.7 Stability 4.8 Concrete Slab ATC TABLE OF JOB NO: PAGE 1 2 3 3 4 S 8 10 11 13 14 15 16 17 Attachment A (Computer Analysis) (1/ pg) Total No. of Pages ea Pages CLIENT: SMART & FINAL PROJECT: STORAGE RACK DESIGN 0101-11792 PAGE OF '7 . ',-;';i'ilu;:.-vixokzazzo.oanarcat'• 0 1.0 PURPOSE The purpose of this calculation is to investigate the structural adequacy of structural members, and connections of the storage racks being installed at ground level of Smart & Final facilities, in Tukiwala, Washington. By inspection, qualificatiopn of Type A racks Envelopes acceptance of Type B, and Type C racks. Effects of Dead Load (DL), Live Load (LL), Impact Load (IL), and Seismic Load (EQ), in accordance with the applicable codes as specified in the Reference Section (next page) are considered. 2.0 REFERENCE„ 111 "Uniform Building Code (UBC) , 1997 Edition 121 "Specification For The Design, Testing, and Utilization of Industrial Steel Storage Racks", June 1990 Edition, by Rack Manufacturers Institute. [3] "Cold Formed Steel Design Manual", 1986 Edition, American Iron And Steel Institute (AISI). 14J "Manual of Steel Construction", 9th Edition, American Institute of Steel Construction (RISC). 15] "Building Code Requirements For Reinforced Concrete", ACI -318, American Concrete Institute. [6] "Design of Welded Structures", by Omar Blodgett. [71 "Report Number 4627'; by International Conference Of Building Officials (ICBO), for "Hilti Kwik 11 Wedge Anchor bolts" . KM 1/16/01 REV BY DATE Advanced Technical Consulting CLIENT: SMART & FINAL PROJECT: STORAGE RACK DESIGN JOB NO: 0101 -11792 PAGE 3 OF 17 4 13 II II 0 3.0SMRAGERICKERQE/LE KM 1/16/01 AL_ ;t tr REV BY DATE Advanced Technical Consulting JOB NO: 4/0■•••■=. 0 IL. CLIENT: SMART & FINAL 0101-11792 Lu 4 ' PROJECT: STORAGE RACK DESIGN PAGE 4- OF / 3.0 STORAGE RACK PROFILE r r- 1 1 0 1/16/01 REV BY DATE Advanced Technical Consulting CLIENT: SMART & FINAL PROJECT: STORAGE RACK DESIGN JOB NO: 0101-11792 PAGE 5 OF / 7 3.0 STORAGE R4 CJU ROIi JLE 0 REV KM BY 1/16/01 DATE 4 D a Advanced Technical Consulting N JOB NO: 0 U- u z CLIENT: SMART & FINAL PROJECT: STORAGE RACK DESIGN 0101 -11792 PAGE OF cu U N O n co LL W } o N W 0 n o § w I I 0 ui z 0 4.0 DESIGN CRITER,(A 1 Codes 2 Seismic Loads 3 Material Properties KM 4 Rack Configuration 116/01 Structural Steel (Min Fy) = 50 KSI Steel Plates (Min Fy) = 36 KSI Slab Thickness = 5 IN Concrete Strength = Fc = 2500 PS! Allowable Soil Pressure = Q = 1000 PSF Column Spacing (Longitudinal Direction) = 96 IN Column Spacing (Transverse Direction) = 18 IN Number of Load Beams = 4 Height to 1st Load Beam = 8 IN Height to 2nd Load Beam = 36 IN Height to 3rd Load Beam = 64 IN Height to 4th Load Beam = 94 IN Height of the Top load Beam = 94 IN Overall Height of Uprights = 94 IN Number of Transverse Bracing Panels = 3 Distance Between Floor and 1st Brace = 10 IN Average Pallet Weight = 50 LB Max. Pallet Weight = 60 LB Number of Pallets Per Level = 10 Max Live Load Per Level = LL = 600 LB REV By DATE Advanced Technical Consulting See Reference Section CLIENT: JOB NO: Zone 3 SMART & FINAL PROJECT: STORAGE RACK DESIGN / 7 0 REV 4.1 SEISMIC LOADS; As permitted by Section 1612.3.2 of 1997 UBC, earthquake load are divided by 1.4, since Allowable Stress Design (ASD) methodology is used in the calculations. Down Aisle Base Shear (UBC section 630,E and 22285) hn =7.83 Ft. Na = 1.00 T = Ct (hn)^0.75 =0.16 Sec Nv = 1.00 Ca = 0.36 I = 1.00 Z = 0.30 Soil Type = SD R = 5.60 W = DL +0.5 *LL= (With min. of 4 columns in this direction, UBC 2228.5.2) UBC Equation (30 -4) V = (111.4)* [Cv * 1 / (R *T) ] * W = 0.000 *W (30 -5) V = (111.4)* X2.5 * Ca * 11 RJ * W = 0.115 *W (Max.) USE THIS (30-6) V = (111.4)* [0.11 * Ca * I J * W = 0.028 *W (Min.) (30 -7) V = (1/1.4) *70.8 * Z * Nv * 11 RI * W = 0.031 *W (Min.) (For a single interior post) Total Vertical Load on a single interior post = DL + LL 1/2 of Upright Weight = 0.120 KIP Beam Weight Per Ft = 0.004 KIP /FT DL = Upright + Beams = 0.25 KIP LL = (Number of Levels) x (Max. LL Per Level) = 1.20 KIP Total Vertical Load = DL + LL = 1.45 KIP V (in down aisle direction) = 0.17 KIP Cross Aisle Base Shear_a BC section 1630.2 and 22285) hn =7.83 Ft. T = Ct (hn)^0.75 =0.09 Sec Ca= 0.36 Soil Type = SD R = 4.40 W = DL +0.5 *LL= (With min. of 4 columns in this direction, UBC 2228.5.2) UBC Equation (30 -4) V = (111.4)* [Cv * 1 / (R *T)] * W = 0.000 *W (30 -5) V = (111.4)* [2.5 * Ca * 11 RI * W = 0.146 *IV (Max.) USE THIS (30-6) V = (111.4)* [0.11 * Ca * I ] * W = 0.028 *W (Min.) (30 -7) V = (1 /1.4) *(0.8 * Z * Nv * 11 RJ * W = 0.039 *W (Min.) (For a single interior post) Total Vertical Load = DL + LL = 1.45 KIP V (in cross asile direction) = 0.21 KIP KM BY 1/16/01 DATE Advanced Technical Consulting Na = 1.00 Nv = 1.00 1 = 1.00 Z = 0.30 CLIENT: SMART & FINAL PROJECT: STORAGE RACK DESIGN JOB NO: 0101 -11792 OF /7 LEVEL Wx (KIP) Hx (Ft) WxHx (K -Ft) Fx (KIP) Oh CC N ■Z h !t rn N ti 1.0 7.8 7.8 0.098 1.0 5.3 5.3 0.067 1.0 3.0 3.0 0.038 1.0 0.7 0.7 0.008 TOTAL 16.8 0.212 L EVEL Wx (KIP) Hx (Ft) WxHx (K -Ft) Fx (KIP) Ov--, ON CO n \t in tt en N ,--, 1.0 7.8 7.8 0.077 1.0 5.3 5.3 0.053 1.0 3.0 3.0 0.030 1.0 0.7 0.7 0.007 TOTAL 16.8 0.166 0 REV Vertical Distribution of Seismic Forces; Fx = (WxHx) I (Sum WxHx) From Ref [1 Since All Levels Have the Same Load Use Wx = 1.0 Note that in the transverse direction, following horizontal loads are applied to each post. KM BY 1 /16 /01 DATE Down Aisle Direction Cross Aisle Direction Advanced Technical Consulting CLIENT: SMART & FINAL PROJECT: STORAGE RACK DESIGN JOB NO: 0101 -11792 PAGE OF ► 7 42_ BEAMS 0 KM Min Fy = 50 KSI Factor of Safety = FS = 1.65 Allowable Bending Stress = Fb = Fy /FS = 30 KSI Area = A = 0.722 IN "2 Moment of Inertia = 1= 0.760 IN ^4 Section Modulus = S = 0.466 IN ^3 Radius of Giration= R = 1.026 IN Thickness = t = 0.075 IN Beam Length = L = 8.0 FT Beam Length = L = 96.0 IN DL of Bean Per Foot = 0.004 KIP /FT Max LL Per Shelve = LL = 0.6 KIP Uniform LL For a Single Beam = LLIf(2)(L)J = 0.038 KIP /FT Impact Load (IL) = (0.25)(Avg. Pallet Weight) = 13 LB Max Impact Load (IL) Per Level = 0.01 KIP Uniform Impact Load (IL) Per Beam = (IL /2) /L = 0.001 KIPIFT Uniform DL + LL per Beam = WI = 0.042 KIP /FT Uniform DL + LL + IL per Beam = W2 = 0.042 KIP /FT 1/16/01. Max Moment = M = (W2)(L ^2)/8 = 0.3 KIP -FT Required Section = Sreq = (M)(12) /Fb = 0.134 IN ^3 Provided Section = Sprov = 0.466 Sprov > Seq Allowable Deflection = Da Da = L /180 = 0.53 IN Actual Deflection = D D = 5(W1) (L') (L "^3)/ f (384) (29.5E3) (1)] = 0.17 < Da O.K. ATC REV BY DATE Advanced Technical Consulting CLIENT: SMART & FINAL PROJECT: STORAGE RACK DESIGN JOB NO: 0101 -11792 O.K. PAGE /0 OF / 7 93 COLUMNS Calculate Capacity KM BY 1/16/01 Min Fy = 50 KSI Compression Factor of Safety = FS = 1.92 DATE Advanced Technical Consulting Column Properties A = 0.411 INA2 lx = 0.582 IN ^4 Sx = 0.388 IN ^3 Rx = 1.156 IN ly = 0.205 INA4 Sy = 0.219 IN ^3 Ry = 0.686 IN t = 0.07.5 IN Unbraced Length in X Direction = Lx = 28.0 IN Unbraced Length in YDirection = Ly = 24.7 IN Kx 1.5 Ky = 1.0 KrLx /Rx = 36.3 KyLylRy = 36.0 (KLIR)rnax = 36.3 F'e = (12E)(3.14 ^2) /(23[(KL /R) ^2J} = 113.0 C c = (2E, ^2 /Fv) ^0.5 = 107 For KL /R less than C c Fa = 26.3 KSI CLIENT: SMART & FINAL PROJECT: STORAGE RACK DESIGN JOB NO: 0101 -11792 PAGE it OF aZ 0 Evaluation of Columns (Cont'd) DL + LI, + Moment Due to 1..5% W (Ref. (2 ) KM 1/16/01 Moment Arm = L = DL = LL = Total Axial Load = P = DL + LL = 1.5% Moment = M = 0.015(PL /2) = DL + LL + Seismic in Longitudinal Direction Combined Axial + Bending Stresses IR = [(P) /(A Fa)] + [(M)/(Sx Fb)] = 0.1 < 1.0 O.K. Total Axial Load = P = DL + LL = From Computer Analysis, Moment = M = Combined Axial + Bending Stresses IR = f (P) /(A Fa)] + f (M)(12) /(Sx Fb)] = 0.33 < 1.33 O.K. DL + LL +,Seismic in Transverse Direction Axial Load = P1 = DL + LL = From Computer Analysis Seismic Axial Load = P2 = Total Axial Load = P = P1 + P2 = From Computer Analysis, Moment = M = Combined Axial + Bending Stresses IR = [(P) /(A Fa)] + f (M)(12) /(Sy Fb)] = 0.47 < 1.33 O.K. REV BY DATE Advanced Technical Consulting 8.0 IN 0.2 KIP 1.2 KIP 1.4 KIP 0.1 KIP -IN 1.4 KIP 0.19 KIP -FT 1.4 KIP 1.7 KIP 3.1 KIP 0.1 KIP -FT CLIENT: SMART & FINAL PROJECT: STORAGE RACK DESIGN JOB NO: 0101 -11792 PAGE 2 OF /� REV 4,4 .BRACES KM BY 1/16/01 DATE Horiz. Length = Lx = Vert. Length = Ly = Total Length = L = {(Lx ^2) + (Ly = Advanced Technical Consulting L _I A = 0.284 IN ^2 I(min) = 0.046 INN; S(min) = 0.056 IN ^3 R(min) = 0.404 IN t = 0.075 IN 18.0 IN 20.7 IN 27.4 IN K = 0.70 (KLIR)max = 47.5 F'e = (12E)(3.14 ^2) /(23[(KL /R) ^ 21} = 66.25 C c = (2E ^2 /Fy) ^0.5 = 107 Fa = 24.73 KSI From Computer Analysis Seismic Axial Load = P = 1.00 KIP Allowable Seismic Axial Load = Pa KIP Pa = (A)(Fa)(1.33) = 9.34 > P O.K. Weld Capacity Length of weld = D = 3.0 IN Weld Size = w = 0.125 IN Weld Capacity = (w)(0.707)(21 ksi)(D)(1.33) = 7.4 > P O.K. CLIENT: SMART & FINAL PROJECT: STORAGE RACK DESIGN JOB NO: 0101 -11792 PAGE 13 OF I "? 0 45 CONNECTIONS Bolts /Studs Bearing Stress KM Total Number of Bolts /Studs = 3 Distance From Bot. Bolt to Bot. of Connector = XI = 1.0 IN Distance From Mid. Bolt to Bot. of Connector = X2 = 3.0 IN Distance From Top Bolt to Bot. of Connector = X3 = 5.0 IN Total Load Per Single Beam = W = 0.3 KIP Load Per Connector = R = W/2 = 0.2 KIP Direct Shear Per Bolt = V1 = (R /No. of Bolts) = 0.055 KIP /BOLT From Computer Analysis Seismic Moment = M = From geometry, and similar Triangles Max Shear Per Bolt Due to Seismic Moment = V2 V2 = (12(M)(X3)J I ((XI ^2) + (X2 ^2) + (X3 ^2)J = Resultant Shear = V = ((V] ^2) + (V2 ^2)J ^0.5 = 0.33 KIP /BOLT Allowable Seismic Shear = Va = (A)(Fv)(1.33) = 3.08 > V O.K. 1/16/01 Bolt /Stud Diameter = D = 0.375 IN Bolt Area = A = 0.110 IN ^2 Bolt Mat. Allow. Shear Stress = Fv = 21 KSI Base Metal Fu = 65.0 KSI Base Metal Thickness = T = 0.075 IN Allowable Bearing Stress (Seismic) = Fp Fp = 1.33(Fu) = 86.5 KSI Actual Bearing Stress = fp fp = V/(TD) = 11.75 < Fp O.K. ATC REV BY DATE Advanced Technical Consulting 0.19 KIP -FT 0.33 KIP /BOLT CLIENT: SMART & FINAL PROJECT: STORAGE RACK DESIGN JOB NO: 0101 -11792 PAGE ►4 IFS REV 4.6 BASE PLATE AND ANCHOR BOLTS KM BY Max. Compressive Load (DL + LL + SL) = P = 3.1 KIP Distributed Load = w = PIA = 0.18 KIP /IN ^2 Base Plate Thickness required = Treq IN Treq = { j(3)(w)(Lc ^2)J I j(0.75)(Fy)(1.33)J ) ^ 0.5 = 0.03 < T O.K. ' II, i '. II i' I. 1/16/01 DATE Base Plate Min Fy = 36 KSI Base Plate Thickness = T = 0.38 IN Base Plate Width = b = 3.50 IN Base Plate Length = d = 5.00 IN Base Plate Area = A = 17.50 IN "2 Bolt to plate Edge Distance = Le = 0.75 IN Bolt to Bolt distance = Lb = 3.50 IN Bolt to Column Edge Distance = Lc = 0.25 IN Transverse Direction (Base FL Critical) Longitudi al Direction (Anchor Bolt Critical) Max Compressive Load = P = Max Shear Load = V = Max Moment = M = Number of Bolts = N = 1 Bolt Diameter = 0.50 IN Perpendicular Bolt to Bolt Distance = Lb = 3.50 IN Min Concrete Strenght = Fc = 2500 PSI Min Bolt Embedment = 3.50 IN Bolt Tension Allow (Ref. (71) = Ta = 0.875 KIP Bolt Shear Allow (Ref 17J) = Va = 1.840 KIP Special Inspection Required = NO Bolt Tension Allow (Ref. 17J) = Ta = 1.164 KIP Bolt Shear Allow (Ref j7J) = Va = 2.447 KIP Advanced Technical Consulting JOB NO: 1.45 KIP 0.17 KIP 0.00 KIP -FT CLIENT: SMART & FINAL PROJECT: STORAGE RACK DESIGN 0101 -11792 PAGE l S OF I 7 (Base P1 & Anchor Bolts Cont'd) 4.7 STABILITY moire Rack Loaded KM REV BY 1 /16/01 DATE Max Tension Per Bolt = T T = [(M)(12)1(N/2)(Lb)J - (P)(0.5) = Max Shear Per Bolt = V V = (V)I(N) = Combined Tension & Shear Interaction = IR IR = [(T)/(Ta) J ^5/3 + [(V)1(Va)1^513 = To Shel_f_Loaded Only Downward Force due to pallets on top shelf = F = Seismic Force @ top = V = Distance From Top Shelf to Floor = H = Overturning Moment = OTM Factor of Safety = FS = OTM = (V)(H)(FS) = Restoring Moment Due to LL = RS Distance Between Columns of Upright = D = RM Due to LL = RM = (F)(D/2) = Total Number of Bolts Per Column = N = T = Tension I Bolt = (OTM- RM) /ND = V = Shear I Bolt = V/2N = Bolt Tension Allow (Ref [7J) = Ta = Bolt Shear Allow (Ref. [7]) = Va = IR = j(T) /(Ta)J ^5/3 + j(l ')1(Va)J ^5/3 = Downward Force = F = Total Seismic Force = V = Factor of Safety = FS = OTM = (V) (2/3) (H) (FS) = RM Due to LL = RM1 = (F)(D/2) = T = Tension I Bolt = (OTM- RM) /ND = V = Shear / Bolt = V/2N = Bolt Tension Allow (Ref. [7]) = Ta = Bolt Shear Allow (Ref [7]) = Va = IR = [(T)/(Ta)J ^5/3 + [(V) /(Va)J ^5/3 = Advanced Technical Consulting CLIENT: JOB NO: 0.00 KIP /BOLT 0.166 KIP/ BOLT 0.01 < 1.0 O.K. 0.6 KIP 0.088 KIP 94.0 IN 1.5 12.4 KIP -IN 18.0 IN 5.4 KIP -IN 1 0.39 KIP /BOLT 0.044 KIPIBOLT 1.164 KIP /BOLT 2.447 KIP /BOLT 0.16 < 1.0 O.K. 2.4 KIP 0.423 KIP 1.15 30.5 KIP -IN 21.6 KIP -IN 0.49 KIP /BOLT 0.212 KIP /BOLT 1.164 KIP/BOLT 2.447 KIP/BOLT 0.26 < 1.0 O.K. SMART & FINAL PROJECT: STORAGE RACK DESIGN 0101 -11792 P A GE CP OF I -? 0 4.8 CONCRF. TE SLAB Concrete Compressive Strength = Fc = 2500 PSI Soil Bearing Pressure = Q = 1000 PSF Maximum Axial Load Per Base Plate (DL + LL + SL) = P = 3.1 KIP Concrete Thickness = T = 5.0 IN Base Plate Width = b = 3.5 IN Base Plate Length = d = 5.0 IN KM Allowable Stress = Fv = (2) f (Fc) ^ (0.5)](1.33) = 133 PSI Actual Punching Shear Stress = fv fv = f (P)(1000)J 1 [2(T)(h + d + 27)] = 16.8 < Fv O.K. Bearing Stros Allowable Bearing Stress = Fb = (0.35)(Fc)(1.33) = 1164 PSI Actual Bearing Stress = fb Jb = J(P) (1000) J / f(b) (d)] = 177.6 < Fb O.K. Area of Influence = A A = (P)(1000) /(Q) = Side Lengths of an Equivalent Square = D = (A ^0.5) = Moment for a One Ft. Strip = M Moment Arm = L = (0.5)(12D- d- 2T)/12 = 0.3 FT M = (Q)(L A 2) I (3)(1000) = 0.02 KIP -FT Sec. Mod. of a 1' Ft Concrete Strip = S = (12)(T"2)/6 = 50.0 IN ^3 Allowable Bending Stress = Fb = (1.9)(Fc A 0.5)(1.33) = 126.4 PSI Actual Bending Stress = Jb Jb = M(12)(1000) /S = 5.3 < Fb O.K. 1/16/01 Punching Shear Binding Stress REV BY DATE Advanced Technical Consulting 3.1 FTA2 1.8 FT CLIENT: SMART & FINAL PROJECT: STORAGE RACK DESIGN JOB NO: 0101 -11792 PAGE 1 7 OF KM 1/16/01 ATTACHMENT A REV BY DATE Advanced Technical Consulting CLIENT: SMART & FINAL PROJECT: STORAGE RACK DESIGN JOB NO: 0101 -11792 7 FRAME MAC file: SMART & FINAL; Last modified at 4:13:35 PM on Thu, Jan 18, 2001 • • *:*-' 22 16 g Input Data ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FRAME MAC file: SMART & FINAL. Last modified at 4:13:35 PM on Thu, Jan 18, 2001. All coord. and distances are in inch. There are 30 nodes and 37 elements. There are 66 degrees of freedom; the half- bandwidth is 23. ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Node information: Node Location Location Restraint Restraint Restraint Hinge No. inch (X)inch (X) (Y) (FX) (FY) (M2) 1 0.000 0.000 Yes Yes No No 2 99.000 0.000 Yea Yes No No 3 300.000 0.000 Yes Yes No No 4 318.000 0.000 Yes Yes No No 5 - 99.000 8.000 No Yes Yes No 6 0.000 8.000 No No No No 7 99.000 8.000 No No No No 8 198.000 8.000 No Yes Yes No 9 300.000 9.960 No No No No 10 318.000 9.960 No No No No 11 - 99.000 36.000 No Yea Yes No 12 0.000 36.000 No No No No 13 99.000 36.000 No No No No 14 198.000 36.000 No Yes Yes No 15 300.000 36.000 No No No No 16 318.000 36.000 No No No No 17 - 99.000 64.000 No Yes Yes No 18 0.000 64.000 No No No No 19 99.000 64.000 No No No No 20 198.000 64.000 No Yes Yes No 21 300.000 64.000 No No No No 22 318.000 64.000 No No No No 23 300.000 84.000 No No No No 24 318.000 84.000 No No No No 25 - 99.000 94.000 No Yes Yes No 26 0.000 94.000 No No No No 27 99.000 94.000 No No No No 28 198.000 94.000 No Yes Yes No 29 300.000 94.000 No No No No 30 318.000 94.000 No No No No ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Element characteristics: From, To Length Section E Include Top is on Hinged at Nodes inch name ksi self wt.top or left node(s) 1,6 8.000 2,7 8.000 3,9 9.960 4,10 9.960 5,6 99.000 6,7 99.000 6,12 28.000 7,8 99.000 7,13 28.000 9,10 18.000 COLX 29000.000 No Yes COLX 29000.000 No Yes COLY 29000.000 No Yes COLY 29000.000 No Yes BEAM 29000.000 No Yes BEAM 29000.000 No Yes COLX 29000.000 No Yes BEAM 29000.000 No Yes COLX 29000.000 No Yes BRACE 29000.000 No Yes ,40/1 9,15 10,16 10,15 11,12 12,18 12,13 13,19 13,14 15,21 15,16 15,22 16,22 17,18 18,26 18,19 19,27 19,20 21,23 21,22 22,24 22,23 23,29 23,24 24,30 25,26 26,27 27,28 26.040 26.040 31.656 99.000 28.000 99.000 28.000 99.000 28.000 18.000 33.287 28.000 99.000 30.000 99.000 30.000 99.000 20.000 18.000 20.000 26.907 10.000 18.000 10.000 99.000 99.000 99.000 COLY 29000.000 No Yes COLY 29000.000 No Yes BRACE 29000.000 No Yes BEAM 29000.000 No Yes COLX 29000.000 No Yes BEAM 29000.000 No Yes COLX 29000.000 No Yes BEAM 29000.000 No Yes COLY 29000.000 No Yes BRACE 29000.000 No Yes BRACE 29000.000 No Yes COLY 29000.000 No Yes BEAM 29000.000 No Yes COLX 29000.000 No Yes BEAM 29000.000 No Yes COLX 29000.000 No Yes BEAM 29000.000 No Yes COLY 29000.000 No Yes BRACE 29000.000 No Yes COLY 29000.000 No Yes BRACE 29000.000 No Yes COLY 29000.000 No Yes BRACE 29000.000 No Yes COLY 29000.000 No Yes BEAM 29000.000 No Yes BEAM 29000.000 No Yes BEAM 29000.000 No Yes MEN 4WD MO ************************************************* * * * * ** * * * * * * * * * * * ** * * * * * * * * * *** Element characteristics (continued): From, To Area Depth Thickness Weight Weight Nodes in * *2 in in lb /ft kip 1,6 0.41 3.00 0.08 2.50 0.00 2,7 0.41 3.00 0.08 2.50 0.00 3,9 0.41 1.63 0.08 2.50 0.00 4,10 0.41 1.63 0.08 2.50 0.00 5,6 0.72 3.00 0.06 2.50 0.02 6,7 0.72 3.00 0.06 2.50 0.02 6,12 0.41 3.00 0.08 2.50 0.01 7,8 0.72 3.00 0.06 2.50 0.02 7,13 0.41 3.00 0.08 2.50 0.01 9,10 0.28 1.25 0.08 2.00 0.00 9,15 0.41 1.63 0.08 2.50 0.01 10,16 0.41 1.63 0.08 2.50 0.01 10,15 0.28 1.25 0.08 2.00 0.01 11,12 0.72 3.00 0.06 2.50 0.02 12,18 0.41 3.00 0.08 2.50 0.01 12,13 0.72 3.00 0.06 2.50 0.02 13,19 0.41 3.00 0.08 2.50 0.01 13,14 0.72 3.00 0.06 2.50 0.02 15,21 0.41 1.63 0.08 2.50 0.01 15,16 0.28 1.25 0.08 2.00 0.00 15,22 0.28 1.25 0.08 2.00 0.01 16,22 0.41 1.63 0.08 2.50 0.01 17,18 0.72 3.00 0.06 2.50 0.02 18,26 0.41 3.00 0.08 2.50 0.01 18,19 0.72 3.00 0.06 2.50 0.02 19,27 0.41 3.00 0.08 2.50 0.01 19,20 21,23 21,22 22,24 22,23 23,29 23,24 24,30 25,26 26,27 27,28 0.72 3.00 0.72 0.41 0.28 0.41 0.28 0.41 0.28 0.41 0.72 0.72 3.00 1.63 1.25 1.63 1.25 1.63 1.25 1.63 3.00 3.00 0.06 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.06 0.06 0.06 2.50 2.50 2.00 2.50 2.00 2.50 2.00 2.50 2.50 2.50 2.50 0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.02 0.02 ***************************************** * * * * * * * * * * ********** *******a * ** Element characteristics (continued): From, To Iz Sec. mod. Rad. gyr. N.A. -edge S,T,L Nodes in * *4 in * *3 in in 1,6 0.58 0.39 1.16 1.50 S 2,7 0.58 0.39 1.16 1.50 S 3,9 0.20 0.22 0.69 0.69 S 4,10 0.20 0.22 0.69 0.69 S 5,6 0.76 0.47 1.03 1.50 S 6,7 0.76 0.47 1.03 1.50 S 6,12 0.58 0.39 1.16 1.50 S 7,8 0.76 0.47 1.03 1.50 S 7,13 0.58 0.39 1.16 1.50 S 9,10 0.05 0.06 0.40 0.38 S 9,15 0.20 0.22 0.69 0.69 S 10,16 0.20 0.22 0.69 0.69 S 10,15 0.05 0.06 0.40 0.38 S 11,12 0.76 0.47 1.03 1.50 S 12,18 0.58 0.39 1.16 1.50 S 12,13 0.76 0.47 1.03 1.50 S 13,19 0.58 0.39 1.16 1.50 S 13,14 0.76 0.47 1.03 1.50 S 15,21 0.20 0.22 0.69 0.69 S 15,16 0.05 0.06 0.40 0.38 S 15,22 0.05 0.06 0.40 0.38 S 16,22 0.20 0.22 0.69 0.69 S 17,18 0.76 0.47 1.03 1.50 S 18,26 0.58 0.39 1.16 1.50 S 18,19 0.76 0.47 1.03 1.50 S 19,27 0.58 0.39 1.16 1.50 S 19,20 0.76 0.47 1.03 1.50 S 21,23 0.20 0.22 0.69 0.69 S 21,22 0.05 0.06 0.40 0.38 S 22,24 0.20 0.22 0.69 0.69 S 22,23 0.05 0.06 0.40 0.38 S 23,29 0.20 0.22 0.69 0.69 S 23,24 0.05 0.06 0.40 0.38 S 24,30 0.20 0.22 0.69 0.69 S 25,26 0.76 0.47 1.03 1.50 S 26,27 0.76 0.47 1.03 1.50 S 27,28 0.76 0.47 1.03 1.50 S Total frame weight: 0.35 kip. ************************ * * ** * * *** ****** * * * * ** *** ** *** *, tit * ** ****** **** **** * * ** ** Node loads (only those that are in applied groups are listed): Node Force or Group Magnitude Magnitude Magnitude / No. moment kip (FX) kip (FY) kip -ft (MZ) 6 Force Misc. 1 0.007 0.000 7 Force Misc. 1 0.007 0.000 9 Force Misc. 1 0.008 0.000 10 Force Misc. 1 0.008 0.000 12 Force Misc. 1 0.030 0.000 13 Force Misc. 1 0.030 0.000 15 Force Misc. 1 0.038 0.000 16 Force Misc. 1 0.038 0.000 18 Force Misc. 1 0.053 0.000 19 Force Misc. 1 0.053 0.000 21 Force Misc. 1 0.067 0.000 22 Force Misc. 1 0.067 0.000 26 Force Misc. 1 0.077 0.000 27 Force Misc. 1 0.077 0.000 29 Force Misc. 1 0.098 0.000 30 Force Misc. 1 0.098 0.000 General load factor: 1.000 Load factors (suffix denotes whether the group is currently applied): Group Dead Live Wind Snow Misc. 1 1.000Y 1.000Y 1.000Y 1.000Y 1.000Y 2 1.000Y 1.000Y 1.000Y 1.000Y 1.000Y 3 1.000Y 1.000Y 1.000Y 1.000Y 1.000Y 4 1.000Y 1.000Y 1.000Y 1.000Y 1.000Y 5 1.000Y 1.000Y 1.000Y 1.000Y 1.000Y "KO/ Output Data ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FRAME MAC file: SMART & FINAL. Last modified at 4:13:35 PM on Thu, Jan 18, 2001. All coord. and distances are in inch from the left (bot.) end of the element. ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Support reactions: (pos. force is to right or up; pos. moment is ccw.) Node Reaction Reaction Reaction No. kip (FX) kip (FY) kip -ft (MZ) ia i" i; �s�'. t, g'` ==t .,..�.e >. �,..:;: •.:.,_..: -r;+ 1 -0.167 -0.071 2 -0.167 0.071 3 -0.201 -1.661 4 -0.221 1.661 - -- 5 - -- -0.022 -0.060 8 - -- 0.022 -0.060 11 - -- -0.023 -0.063 14 - -- 0.023 -0.063 17 - -- -0.017 -0.048 20 - -- 0.017 -0.048 25 - -- -0.009 -0.025 28 - -- 0.009 -0.025 dM ONO AIM ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Node deformations: (positive is to right, up, or counterclockwise.) Node Deflection Deflection Rotation No. inch (FX) inch (FY) radians (MZ) 1 0.000 0.000 -0.002 2 0.000 0.000 -0.002 3 0.000 0.000 -0.004 4 0.000 0.000 -0.004 5 0.015 0.000 0.000 6 0.015 0.000 -0.002 7 0.015 -0.000 -0.002 8 0.015 0.000 0.000 9 0.031 0.001 -0.002 10 0.032 -0.001 -0.002 11 0.079 0.000 0.000 12 0.079 0.000 -0.002 13 0.079 -0.000 -0.002 14 0.079 0.000 0.000 15 0.047 0.005 -0.000 16 0.048 -0.003 -0.000 17 0.134 0.000 0.000 18 0.134 0.000 -0.001 19 0.134 -0.000 -0.001 20 0.134 0.000 0.000 21 0.067 0.006 -0.001 22 0.067 -0.005 -0.001 23 0.081 0.006 -0.001 24 0.081 -0.005 -0.001 25 0.174 0.000 0.000 26 0.174 0.000 -0.001 27 0.174 -0.000 -0.001 28 0.174 0.000 0.000 29 0.099 0.006 -0.002 30 0.101 -0.005 -0.002 ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Actual element end forces & moments: (local coordinate system) From, To FxL FyL MzL FxR FyR MzR Nodes kip kip kip -ft kip kip kip -ft 1,6 2,7 3,9 4,10 5,6 6,7 6,12 7,8 7,13 9,10 9,15 10,16 10,15 11,12 12,18 12,13 13,19 13,14 15,21 15,16 15,22 16,22 17,18 18,26 18,19 19,27 19,20 21,23 21,22 22,24 22,23 23,29 23,24 24,30 25,26 26,27 27,28 -0.071 0.071 -1.661 1.661 0.000 0.000 - 0.049 0.000 0.049 -0.252 -1.569 0.793 0.937 0.000 -0.026 0.000 0.026 0.000 -0.353 - 0.116 - 0.532 0.799 0.000 -0.009 0.000 0.009 0.000 - 0.351 0.008 0.034 0.422 0.000 - 0.141 0.000 0.000 0.000 0.000 0.167 0.167 0.201 0.221 -0.022 -0.044 0.160 - 0.022 0.160 -0.092 -0.059 -0.059 -0.010 -0.023 0.130 -0.046 0.130 -0.023 0.020 0.006 0.003 0.020 - 0.017 0.077 - 0.035 0.077 - 0.017 - 0.039 -0.001 -0.043 -0.005 0.098 -0.034 0.098 -0.009 -0.018 - 0.009 0.000 0.071 -0.167 0.111 0.000 -0.071 -0.167 0.111 0.000 1.661 -0.201 0.167 0.000 -1.661 -0.221 0.183 - 0.060 0.000 0.022 -0.121 - 0.181 0.000 0.044 -0.181 0.190 0.049 -0.160 0.183 -0.121 0.000 0.022 -0.060 0.190 -0.049 -0.160 0.183 - 0.069 0.252 0.092 -0.069 - 0.098 1.569 0.059 -0.031 - 0.095 -0.793 0.059 -0.032 -0.008 -0.937 0.010 -0.019 - 0.063 0.000 0.023 -0.126 0.131 0.026 -0.130 0.172 -0.188 0.000 0.046 -0.188 0.131 -0.026 -0.130 0.172 - 0.126 0.000 0.023 -0.063 0.029 0.353 -0.020 0.018 0.005 0.116 -0.006 0.005 0.005 0.532 -0.003 0.003 0.028 -0.799 -0.020 0.018 -0.048 0.000 0.017 -0.096 0.067 0.009 -0.077 0.125 -0.143 0.000 0.035 -0.143 0.067 -0.009 -0.077 0.125 - 0.096 0.000 0.017 -0.048 - 0.017 0.351 0.039 -0.048 - 0.001 -0.008 0.001 -0.001 - 0.017 -0.034 0.043 -0.055 - 0.009 -0.422 0.005 -0.003 0.082 0.000 -0.098 0.000 -0.025 0.141 0.034 -0.026 0.082 0.000 -0.098 0.000 -0.025 0.000 0.009 -0.050 - 0.075 0.000 0.018 -0.075 -0.050 0.000 0.009 -0.025 ************************************************* * * * * * * * * * * * * * * * * * * ** * * * * * * * * * ** Maximum deformations: No nodes moved to the left. Node 26 moved 0.174 inch to the right. Node 24 moved 0.005 inch downwards. Node 29 moved 0.006 inch upwards. Node 4 rotated0.004 radian clockwise. No nodes rotated counter- clockwise. Maximum reactions: The reaction at node The reaction at node The reaction at node The reaction at node The reaction at node The reaction at node 4 was 0.221 kip to the left. 20 was 0.000 kip to the right. 3 was 1.661 kip downwards. 4 was 1.661 kip upwards. 11 was 0.063 kip -ft clockwise. 4 was 0.000 kip -ft counter - clockwise. EIA Maximum tension and tensile stress From, To Maximum Minimum Node tension tension kip kip 1,6 2,7 3,9 4,10 5,6 6,7 6,12 7,8 7,13 9,10 9,15 10,16 10,15 11,12 12,18 12,13 13,19 13,14 15,21 15,16 15,22 16,22 17,18 18,26 18,19 19,27 19,20 21,23 21,22 22,24 22,23 23,29 23,24 24,30 25,26 26,27 27,28 ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ***************************************,********* * * * * ** * * * * * * * * * * * * * * * * * * * * * * * ** Maximum shear and shear stress values: From, To Maximum Minimum Max. abs. Node shear shear shear kip kip kip 4WD ilm• 1,6 2,7 3,9 4,10 5,6 6,7 6,12 7,8 0.071 0.000 1.661 0.000 0.000 0.000 0.049 0.000 0.000 0.252 1.569 0.000 0.000 0.000 0.026 0.000 0.000 0.000 0.353 0.116 0.532 0.000 0.000 0.009 0.000 0.000 0.000 0.351 0.000 0.000 0.000 0.000 0.141 0.000 0.000 0.000 0.000 0.167 0.167 0.201 0.221 0.000 0.000 0.160 0.000 0.000 -0.071 0.000 - 1.661 0.000 0.000 0.000 0.000 - 0.049 0.000 0.000 -0.793 -0.937 0.000 0.000 0.000 - 0.026 0.000 0.000 0.000 0.000 - 0.799 0.000 0.000 0.000 -0.009 0.000 0.000 -0.008 - 0.034 -0.422 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 -0.022 -0.044 0.000 -0.022 values (compression is negative): Max. abs. Maximum Minimum Max. abs. tension ten. str. ten. str. stress kip ksi ksi ksi 0.071 -0.071 1.661 -1.661 0.000 0.000 0.049 0.000 -0.049 0.252 1.569 - 0.793 -0.937 0.000 0.026 0.000 -0.026 0.000 0.353 0.116 0.532 -0.799 0.000 0.009 0.000 - 0.009 0.000 0.351 - 0.008 - 0.034 -0.422 0.000 0.141 0.000 0.000 0.000 0.000 0.167 0.167 0.201 0.221 - 0.022 - 0.044 0.160 - 0.022 0.172 0.000 4.041 0.000 0.000 0.000 0.119 0.000 0.000 0.889 3.817 0.000 0.000 0.000 0.064 0.000 0.000 0.000 0.858 0.410 1.874 0.000 0.000 0.022 0.000 0.000 0.000 0.855 0.000 0.000 0.000 0.000 0.498 0.000 0.000 0.000 0.000 Maximum shr. str. ksi 0.742 0.742 1.644 1.808 0.000 0.000 0.711 0.000 0.000 -0.172 0.000 -4.041 0.000 0.000 0.000 0.000 -0.119 0.000 0.000 - 1.928 -3.298 0.000 0.000 0.000 - 0.064 0.000 0.000 0.000 0.000 -1.943 0.000 0.000 0.000 -0.022 0.000 0.000 -0.028 -0.083 -1.486 0.000 0.000 0.000 0.000 0.000 0.000 Minimum shr. str. ksi 0.000 0.000 0.000 0.000 -0.116 -0.232 0.000 -0.116 0.172 -0.172 4.041 -4.041 0.000 0.000 0.119 0.000 -0.119 0.889 3.817 -1.928 -3.298 0.000 0.064 0.000 - 0.064 0.000 0.858 0.410 1.874 - 1.943 0.000 0.022 0.000 -0.022 0.000 0.855 -0.028 -0.083 -1.486 0.000 0.498 0.000 0.000 0.000 0.000 Max. abs. stress ksi 0.742 0.742 1.644 1.808 -0.116 - 0.232 0.711 - 0.116 /94 / 7,13 9,10 9,15 10,16 10,15 11,12 12,18 12,13 13,19 13,14 15,21 15,16 15,22 16,22 17,18 18,26 18,19 19,27 19,20 21,23 21,22 22,24 22,23 23,29 23,24 24,30 25,26 26,27 27,28 *******, r***************************************** *** **** * *** *** * * *** ** * * * * * * * * ** ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Maximum moment and bending stress values: From, To Maximum Minimum Max. abs. Node moment moment moment kip -ft kip -ft kip -ft 1,6 2,7 3,9 4,10 5,6 6,7 6,12 7,8 7,13 9,10 9,15 10,16 10,15 11,12 12,18 12,13 13,19 13,14 15,21 15,16 15,22 16,22 0.160 0.000 0.000 0.000 0.000 0.000 0.130 0.000 0.130 0.000 0.020 0.006 0.003 0.020 0.000 0.077 0.000 0.077 0.000 0.000 0.000 0.000 0.000 0.098 0.000 0.098 0.000 0.000 0.000 0.111 0.111 0.167 0.183 0.060 0.181 0.183 0.121 0.183 0.069 0.098 0.095 0.008 0.063 0.172 0.188 0.172 0.126 0.018 0.005 0.003 0.018 0.000 - 0.092 - 0.059 - 0.059 - 0.010 - 0.023 0.000 - 0.046 0.000 -0.023 0.000 0.000 0.000 0.000 -0.017 0.000 - 0.035 0.000 - 0.017 - 0.039 - 0.001 - 0.043 -0.005 0.000 - 0.034 0.000 -0.009 - 0.018 - 0.009 0.160 - 0.092 -0.059 -0.059 -0.010 - 0.023 0.130 -0.046 0.130 - 0.023 0.020 0.006 0.003 0.020 - 0.017 0.077 -0.035 0.077 -0.017 - 0.039 -0.001 -0.043 -0.005 0.098 - 0.034 0.098 -0.009 - 0.018 -0.009 0.000 0.111 0.000 0.111 0.000 0.167 0.000 0.183 -0.121 -0.121 - 0.181 0.181 - 0.190 -0.190 - 0.060 0.121 -0.190 -0.190 - 0.069 0.069 - 0.031 0.098 -0.032 0.095 - 0.019 -0.019 - 0.126 -0.126 -0.131 0.172 - 0.188 0.188 - 0.131 0.172 -0.063 0.126 - 0.029 -0.029 -0.005 -0.005 - 0.005 -0.005 - 0.028 -0.028 0.711 0.000 0.000 0.000 0.000 0.000 0.578 0.000 0.578 0.000 0.165 0.066 0.030 0.161 0.000 0.342 0.000 0.342 0.000 0.000 0.000 0.000 0.000 0.802 0.000 0.802 0.000 0.000 0.000 Maximum ben. str. ksi 3.443 3.443 9.143 10.050 1.555 4.657 5.664 3.108 5.664 14.852 5.345 5.231 1.609 1.625 5.319 4.852 5.319 3.246 0.973 0.968 0.625 0.992 0.000 - 0.981 -0.486 -0.481 - 0.109 -0.121 0.000 -0.242 0.000 -0.121 0.000 0.000 0.000 0.000 -0.093 0.000 - 0.184 0.000 -0.093 -0.318 -0.012 - 0.355 - 0.058 0.000 - 0.363 0.000 -0.049 - 0.096 -0.049 Minimum ben. str. ksi 0.000 0.000 0.000 0.000 -3.108 -4.657 -5.883 -1.555 -5.883 - 14.705 -1.720 -1.767 -4.142 - 3.246 - 4.062 -4.852 - 4.062 - 1.625 -1.602 - 1.026 - 1.045 - 1.519 0.711 - 0.981 -0.486 -0.481 - 0.109 -0.121 0.578 - 0.242 0.578 -0.121 0.165 0.066 0.030 0.161 -0.093 0.342 -0.184 0.342 -0.093 -0.318 -0.012 -0.355 -0.058 0.802 -0.363 0.802 -0.049 -0.096 -0.049 Max. abs. stress ksi 3.443 3.443 9.143 10.050 -3.108 4.657 -5.883 3.108 -5.883 14.852 5.345 5.231 -4.142 -3.246 5.319 4.852 5.319 3.246 -1.602 - 1.026 - 1.045 - 1.519 / IP /Ail 17,18 0.048 -0.096 -0.096 1.241 -2.475 -2.475 18,26 0.125 -0.067 0.125 3.870 -2.084 3.870 18,19 0.143 -0.143 0.143 3.689 -3.689 3.689 19,27 0.125 -0.067 0.125 3.870 -2.084 3.870 19,20 0.096 -0.048 0.096 2.475 -1.241 2.475 21,23 0.017 -0.048 -0.048 0.917 -2.628 -2.628 21,22 0.001 -0.001 0.001 0.217 -0.136 0.217 22,24 0.017 -0.055 -0.055 0.931 -3.036 -3.036 22,23 0.009 -0.003 0.009 1.901 -0.731 1.901 23,29 0.000 -0.082 -0.082 0.000 -4.475 -4.475 23,24 0.025 -0.026 -0.026 5.321 -5.625 -5.625 24,30 0.000 -0.082 -0.082 0.000 -4.475 -4.475 25,26 0.025 -0.050 -0.050 0.653 -1.299 -1.299 26,27 0.075 -0.075 0.075 1.923 -1.923 1.923 27,28 0.050 -0.025 0.050 1.299 -0.653 1.299 **************** * *** ** ** * **** ** * * ** * * ** ** ** * * ** erg► * * * ** ** * *** * * ** * * * * *** * * * ***** ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** l December 19, 2001 Mr. Paul Deems 1807 132nd Avenue North, #2 Bellevue, WA 98005 RE: Permit Application No. D01 -024 230 Andover Park East Dear Permit Holder: amity of Tukwila Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 clays. Based on the above, you are hereby advised to: • Call the City Of Tukwila Permit Center at (206) 431 -3670 to schedule a progress / final inspection A progress inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a ono -time extension up_ to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to Jannuary 19, 2002, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation it) this matter. Sincerely, • e 1 Stefanie Spencer Permit Technician Xc: Permit File No. D01 -024 Duane Griffin, Building Official a Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #J00 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206 -431 -3665 ACTIVITY NUMBER: D01 -024 DATE: 1 -30 -01 PROJECT NAME: CASH & CARRY SITE ADDRESS: 230 ANDOVER PK E SUITE NO: XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DEPARTMENTS: � 1 Bui di g Division k Public Works v`IIR< INK Complete Er PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP a Ott, Fire Prevention , 1:6 (r' - C'I Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete TUES /THURS ROUTING: Please Route 71 Structural Review Required APPROVALS OR CORRECTIONS: (ten days) CORRECTION DETERMINATION: Approved ri Approved with Conditions REVIEWER'S INITIALS: Comments: n Revision # After Permit Is Issued Planning Division Permit Coordinator DUE DATE: 2 -1 -2001 Not Applicable LI No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE 3-1-2001 n Approved n Approved with Conditions L Not Approved (attach comments) REVIEWER'S INITIALS: DATE: DUE DATE Not Approved (attach comments) DATE: F6 25- (J52 -0(Mi (f97, DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL .i,l . REGIST,, EXP. D .` CC01 ORBICQ7�>�13203IQ9/22 /2Q0 EFFECTIVE DATE 09/23 /198? , - R B I CONSTRUCTION INC 1807 132ND NE BELLEVUE WA 98005 NOTICE IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. 0 185'-0” 16'-9" 1V-10" 16-10" 16'-10" 16 16'-10" 16'-10" 16-10" 16'-1O 16-10 16'-9" • • • •••• • « • 01. +row. - WW1 1 fl TT fl [I IT ET . n 2C-0" X178'-0" X 14'—O" IHIGH FREEZER (23 DOORS) NEW 10"X10' ROLL-UP DOM. OP 111 0 2 Pd 5 I • F Cash and Carry #561 TUKWILA 36' LOW Ralf SIEVING 20" DEE (54 LOW) 185-0" a , ./.1.0.1% OMNI 1.1 36' LOW 141011LE SHELIANG 20 DEP (54 L) wiii.•■••••31* IXTURE / MERCHANDISING PLAN L erl TO V. I • (.7 t F vr.u. F A NEW PLAN Si.;1:;Mi; 1/4.. AND AMY INCLUDE ADDITIONAL PLAN REVIEW FEES. TOY ftE° CITY OF 11 • RECEIVED 2053Z 4 ..• the Fiin Crk n 3", ar2, ":".i , 2py 1 ;_;"21 (.10r.r; C.if any adtoJ cr.,..'.;; of trac,tor' copy cf app:ovu'd By/' Dat / RP. aerAiati,..rAe, 4e itigr , - Permit No. tt Pliteb JA N 2 0 Z002 SALES AREA STORAGE AREA REVISIONS — C%11 Of 10041 FEB MAIO CENTER 07-12 -°' com or er.ATIFIcA /5 5ro46441 adier • /54 /496 ,067-4/4_s S E:: 4,77c. P twai-II7f2 itr PROJECT DATA DATA GROSS BLDG 18,500 S.F. 17,807 S.F. 693 S.F. GONDOLA 1,276 L.F. GONDOLA TOTAL EXCLUDES PALLET RACKING FROZEN FOOD DOORS 23 REFRIG DAIRY/DELI 20'X52'X 1 4' REFRIG PRODUCE 20'X28'X 1 4' 0 LU 1)01.432.q 1— Cn uJ .cr.r DATE JOB NO 12-1-99 SCALE DRAWN BY 1/Er = 1' DRAWING NO. MP 561FMP 1 „...- 0 • • • •••• • « • 01. +row. - WW1 1 fl TT fl [I IT ET . n 2C-0" X178'-0" X 14'—O" IHIGH FREEZER (23 DOORS) NEW 10"X10' ROLL-UP DOM. OP 111 0 2 Pd 5 I • F Cash and Carry #561 TUKWILA 36' LOW Ralf SIEVING 20" DEE (54 LOW) 185-0" a , ./.1.0.1% OMNI 1.1 36' LOW 141011LE SHELIANG 20 DEP (54 L) wiii.•■••••31* IXTURE / MERCHANDISING PLAN L erl TO V. I • (.7 t F vr.u. F A NEW PLAN Si.;1:;Mi; 1/4.. AND AMY INCLUDE ADDITIONAL PLAN REVIEW FEES. TOY ftE° CITY OF 11 • RECEIVED 2053Z 4 ..• the Fiin Crk n 3", ar2, ":".i , 2py 1 ;_;"21 (.10r.r; C.if any adtoJ cr.,..'.;; of trac,tor' copy cf app:ovu'd By/' Dat / RP. aerAiati,..rAe, 4e itigr , - Permit No. tt Pliteb JA N 2 0 Z002 SALES AREA STORAGE AREA REVISIONS — C%11 Of 10041 FEB MAIO CENTER 07-12 -°' com or er.ATIFIcA /5 5ro46441 adier • /54 /496 ,067-4/4_s S E:: 4,77c. P twai-II7f2 itr PROJECT DATA DATA GROSS BLDG 18,500 S.F. 17,807 S.F. 693 S.F. GONDOLA 1,276 L.F. GONDOLA TOTAL EXCLUDES PALLET RACKING FROZEN FOOD DOORS 23 REFRIG DAIRY/DELI 20'X52'X 1 4' REFRIG PRODUCE 20'X28'X 1 4' 0 LU 1)01.432.q 1— Cn uJ .cr.r DATE JOB NO 12-1-99 SCALE DRAWN BY 1/Er = 1' DRAWING NO. MP 561FMP 1 REVISION REV. DATE /DESC. BY Z. . . , I tAOR Ifs 0 09/0, STAMP . 1 : N/A JOB NO.: 0101 -1 1792 DATE: 1/17/2001 DRAWN BY: N . M . d , — RI Y • CONCRETE SLAB BASE PLATE ANCHOR BOLTS 1/2" DI A. HILTI K NIK I I ,WEDGE ANCHOR BOLT PER I CBO #4627 C1DANCHOR BOLT DETAIL 3 -1/2" MIN. EMBED. BRACKET L I- I /2 "x3 "x 3/16" TYPICAL TC7'P N✓' I E (I) I /2" DIA. HILTI KVAAIK II ANCHOR BOLTS FOR DOUBLE ROHS (4) I /2" DIA. HILTI KWIK II ANCHOR BOLTS FOR SINGLE ROHS BASE PLATE DETAIL 3/e THICK )SIE ELEVATION FRONT ELEVATION -- FR. ,Aht. (q S I DE ELEVATION RONT ELEVATION I - COLUMN 2 - LOAD BEAM 3 - BEAM CONNECTOR 4 - BASE PLATE 5 - HORIZONTAL BRACING w 6 - DIAGONAL BRACING R I - 11 SPACER Qo)SIE ELEVATION 0 FRONT ELEVATION 1 — I `\e' . r . G- +C "7" i= DESIGNED PER REQUIREMENTS OF !GM UNIFORM BUILDING CODE (UBC) AND CHAPTER 22 DIVISION X SECTION 2222 SEISMIC ZONE 3 DESIGN LOAD: RACKS: MAX. 600 lb. PER SHELF LEVEL MAXIMUM TOLERANCE FOR THE I NSTALLT I ON OF COLUMNS IS I INCH IN 10 FEET. FABRICATION AND ERECTION OF THE RACKS SHALL NOT COMMENCE BEFORE APPROVAL BY APPROPRI ATE REGULATORY AGENCIES. IN ONE OR MORE CONSPICUOUS LOCATIONS, A PERMANENT PLAQUE (NOT LESS THAN 50 SQUARE INCH), STATING IN CLEAR PRINT THE "MAX. PERMISSIBLE TOTAL LOAD PER LEVEL" SHALL BE INSTALLED. DEVIATION FROM DETAILS OF THIS DRAWING MAY I MPAIR THE SAFETY OF THE RACK INSTALLATION. RACKS SHALL NOT OBSTRUCT EXIST ( 4 EX I T ILLUMINATIONS), STAIRS, NOR ANY OTHER FIRE ESCAPES. • • • • • • I S1 A ADVANCED TECINCAL CONS Lnrci P.O. BOX 1963 SAN RAMON, CALIFORNIA 94583 TEL: (510) -796 -4411 FAX: (510)- 796 --4412 I tAOR Ifs . ' ' - ; c ""6" ': /- qi 40. fF' .# Q02$S71� -4 G C(`I V w - 4'8 ., 1Cam.' �� 09/0, STAMP . 1 : N/A JOB NO.: 0101 -1 1792 DATE: 1/17/2001 DRAWN BY: N . M . CHECKED BY: K . M. SHEET / OF S 1 — • CONCRETE SLAB BASE PLATE ANCHOR BOLTS 1/2" DI A. HILTI K NIK I I ,WEDGE ANCHOR BOLT PER I CBO #4627 C1DANCHOR BOLT DETAIL 3 -1/2" MIN. EMBED. BRACKET L I- I /2 "x3 "x 3/16" TYPICAL TC7'P N✓' I E (I) I /2" DIA. HILTI KVAAIK II ANCHOR BOLTS FOR DOUBLE ROHS (4) I /2" DIA. HILTI KWIK II ANCHOR BOLTS FOR SINGLE ROHS BASE PLATE DETAIL 3/e THICK )SIE ELEVATION FRONT ELEVATION -- FR. ,Aht. (q S I DE ELEVATION RONT ELEVATION I - COLUMN 2 - LOAD BEAM 3 - BEAM CONNECTOR 4 - BASE PLATE 5 - HORIZONTAL BRACING w 6 - DIAGONAL BRACING R I - 11 SPACER Qo)SIE ELEVATION 0 FRONT ELEVATION 1 — I `\e' . r . G- +C "7" i= DESIGNED PER REQUIREMENTS OF !GM UNIFORM BUILDING CODE (UBC) AND CHAPTER 22 DIVISION X SECTION 2222 SEISMIC ZONE 3 DESIGN LOAD: RACKS: MAX. 600 lb. PER SHELF LEVEL MAXIMUM TOLERANCE FOR THE I NSTALLT I ON OF COLUMNS IS I INCH IN 10 FEET. FABRICATION AND ERECTION OF THE RACKS SHALL NOT COMMENCE BEFORE APPROVAL BY APPROPRI ATE REGULATORY AGENCIES. IN ONE OR MORE CONSPICUOUS LOCATIONS, A PERMANENT PLAQUE (NOT LESS THAN 50 SQUARE INCH), STATING IN CLEAR PRINT THE "MAX. PERMISSIBLE TOTAL LOAD PER LEVEL" SHALL BE INSTALLED. DEVIATION FROM DETAILS OF THIS DRAWING MAY I MPAIR THE SAFETY OF THE RACK INSTALLATION. RACKS SHALL NOT OBSTRUCT EXIST ( 4 EX I T ILLUMINATIONS), STAIRS, NOR ANY OTHER FIRE ESCAPES. • • • • • •