HomeMy WebLinkAboutOrd 2326 - 5-Story Type V-A Buildings (Repealed by Ord 2648)City of'Tukwila Washington Cover page to Ordinance 2326 The full text of the ordinance follows this cover page. AN ORDINANCE Of THE CITY COUNCIL 0$7 TkIE ('37Y OF MKOLA, WASHINGTON, ES•TASUISMINOSPEP AL PROVISIONS FOR 5 -STORY TYPE" V A CONISTRUU10N, TO IBE 00D[FIFE0 AT TUKWILA MUMVPACODE CRAFTER 16.015. "545 FORY TYPE '- IEIUILDIN'8°°E'OOMIINNO FOR SEVERA,BI1,[TY;AND E' TABUS 4NEfIFE(JIVe, OAT . Ordinance 2326 was amended or repealed by the following ordinances. REPEALED SeAttion(s) Repealed ftpealed "' 'Ord # 2648 1908 City of u la Washington Ordinance No. Q3a6 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, ESTABLISHING SPECIAL PROVISIONS FOR 5 -STORY TYPE V -A CONSTRUCTION, TO BE CODIFIED AT TUKWILA MUNICIPAL CODE CHAPTER 16.05, "5 -STORY TYPE V -A BUILDINGS "; PROVIDING FOR SEVERABILITY; AND ESTABLISHING AN EFFECTIVE DATE. WHEREAS, the City Council finds it is in the best interest of the City to provide additional tools to build economically viable mixed -use and multi - family buildings; and WHEREAS, the International Building Code provides for the approval of alternate material, methods of design, and methods of construction; and WHEREAS, RCW 19.27.060 allows cities to amend the State Building Code, provided the application of any that apply within their jurisdiction shall not result in a code that is less than the minimum performance standards and objectives contained in the State Building Code; and . WHEREAS, the City Council finds that providing this alternate method of construction should provide an incentive for the construction of economically viable mixed -use and residential occupancies, which is the City's growth strategy in commercial zones along the Tukwila International Boulevard Corridor, Tukwila Urban Center and the Tukwila South area; NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, HEREBY ORDAINS AS FOLLOWS: Section 1. Regulations Established. Tukwila Municipal Code Chapter 16.05, "5 -Story Type V -A Buildings," is hereby established to read as follows: CHAPTER 16.05 5 -STORY TYPE V -A BUILDINGS Sections: 16.05.010 Purpose of Chapter 16.05.020 Construction 16.05.030 Occupancy 16.05.040 Stair Enclosures 16.05.050 Fire Detection and Protection 16.05.060 Building Height 16.05.070 Basic Allowable Floor Area 16.05.080 Elevators 16.05.090 Fire Department Access 16.05.100 Attic / Roof Ventilation & General Design Requirements 16.05.110 Construction Inspections 16.05.120 Maintenance of Fire Protection Systems W: Word Processing \5 -1 Building Code BB:mrh 3/29/2011 Page 1 of 5 Section 2. TMC Section 16.05.010, "Purpose of Chapter," hereby reads as follows: 16.05.010 Purpose of Chapter The purpose of TMC Chapter 16.05 is to authorize the construction of 5 -story Type V -A buildings as an approved alternate design and construction method under Section 104.11 of the International Building Code, 2009 Edition, and to set forth the criteria and standards which must be met prior to a building permit being issued for a 5 -story Type V -A building. Section 3. TMC Section 16.05.020, "Construction," hereby reads as follows: 16.05.020 Construction A. International Building Code Requirements. Five -story Type V -A buildings shall comply with all requirements of the International Building Code, 2009 Edition, except as specifically required by this chapter. In the event of a conflict between the International Building Code and the provisions of this chapter, the provisions of this chapter shall control. In the event of a conflict between the language in Tukwila Municipal Code Chapter 16.48 and the provisions of this chapter, the provisions of this chapter shall control. References in this chapter to building construction "types" (e.g. Type I, or Type V -A) shall have the same meaning as set forth in the International Building Code, 2009 Edition. B. Lowest Story Construction Requirements. The lowest story in a five -story Type V -A building shall be constructed of Type V -A fire - resistive construction, except that all structural frame and load bearing elements shall be of approved, 2 -hour fire - resistive construction. C. Upper Four Stories. The upper four stories of a five -story Type V -A building shall be constructed of at least Type V -A fire - resistive construction with no exceptions permitted. D. Use of Type V -A Above Type IA Construction. Where Type V -A stories are constructed over Type IA construction, the Type V -A story shall be separated from the Type I stories with a horizontal assembly having a minimum 3 -hour fire resistance rating as provided in the International Building Code, 2009 Edition. Shafts, stairway, ramp and escalator enclosures through the horizontal assembly shall have not less than 2 -hour fire resistance rating with opening protectives in accordance with the International Building Code, 2009 Edition, Section 715.4. No exceptions permitted. E. Non - Load - Bearing Walls. Non -load- bearing walls, exterior and interior walls, shall be construction of at least Type V -A fire - resistive construction, no exceptions permitted. F. Shafts. Shafts shall be constructed of an approved 2 -hour fire - resistive assembly, with duct penetrations protected with fire /smoke dampers rated for 1 -1/2 -hour fire resistance rating. No exceptions permitted. G. Corridors. Except for corridors within a dwelling or sleeping unit, corridors serving an occupant load greater than 10, shall be constructed of 1 -hour fire - resistive construction, and shall comply with the International Building Code, 2009 Edition requirements for "Fire Partitions." No exceptions permitted. Section 4. TMC Section 16.05.030, "Occupancy," hereby reads as follows: 16.05.030 Occupancy A. Occupancy of five -story Type V -A buildings shall be Group R -1 or R -2 Occupancies permitted above the first floor. Group S -2, parking garages, B, M, R, or Multiple Group A occu- pancies, each with an occupant load of less than 300, shall be permitted on the first floor only. B. "Occupancy" shall have the same meaning as set forth in the International Building Code, 2009 Edition. W: Word Processing \5 -1 Building Code BB:mrh 3/29/2011 Page 2 of 5 Section 5. TMC Section 16.05.040, "Stair Enclosures," hereby reads as follows: 16.05.040 Stair Enclosures Where buildings are designed and constructed pursuant to this section, all stair enclosures shall be 2 -hour fire resistive construction with 1 -1/2 -hour opening protection. Stair enclosures shall be pressurized as described in the International Buildina Code, Section 909.20.5. Section 6. TMC Section 16.05.050, "Fire Detection and Protection," hereby reads as follows: 16.05.050 Fire Detection and Protection A. Fire Sprinkler System. Five -story Type V -A buildings shall be protected throughout by an automatic fire sprinkler system as defined in Tukwila Municipal Code Chapter 16.42, the International Building Code. 2009 Edition, the International Fire Code. 2009 Edition and as defined by National Fire Protection Association Standards (NFPA) 13, as set forth herein. The 2009 Editions of the International Building Code and International Fire Code shall be as presently constituted or as hereafter amended. B. Fire Detection System. A monitored manual and automatic fire detection system shall be installed throughout the building with audible and visual alarm signals. Fire alarm installation shall be in accordance with the International Building Code. 2009 Edition, International Fire Code, NFPA 72 and Tukwila Municipal Code Chapter 16.40. C. Equipment and Controls Location. Fire detection system equipment and controls shall be located in a location approved by the Fire Marshal. The monitoring equipment shall be located in a separate room enclosed with 1 -hour fire -rated barriers or horizontal assemblies constructed in accordance with the International Building Code. 2009 Edition,. D. Class I standpipe hose connections are required. A Class I standpipe shall be located in every stairway; a hose connection shall be provided for each floor level and on intermediate floor level landings between floors unless otherwise approved by the Fire Marshal. E. Standby Generator. A standby power generator set shall be provided on the premises in accordance with the Washington Cities Electrical Code and NFPA 70 as presently constituted or hereafter amended. The standby system shall have the capacity and rating to sufficiently supply all equipment required to be operational at the same time, including but not limited to: 1. Emergency lighting; and 2. Stair enclosure and elevator shaft pressurization; and 3. Elevators. Section 7. TMC Section 16.05.060, "Building Height," hereby reads as follows: 16.05.060 Building Height A. The maximum height of buildings designed and constructed pursuant to this section shall be 70 feet. The building height shall be measured as described in the International Building Code. 2009 Edition as presently constituted or hereafter amended. No additional height increases are permitted. B. Where a five -story Type V -A building is to be constructed over a base structure of Type I construction, the overall height of the resulting building shall not exceed 70 feet, as measured from the grade plane. No additional height increases are permitted. W: Word Processing \5 -1 Building Code BB:mrh 3/29/2011 Page 3 of 5 Section 8. TMC Section 16.05.070, "Basic Allowable Floor Area," hereby reads as follows: 16.05.070 Basic Allowable Floor Area The basic allowable area of floors of a five -story Type V -A building shall be as stated in Table 503 and Section 506 of the International Building Code. 2009 Edition, as presently constituted or as hereafter amended. For the purpose of this chapter only, the total allowable area as calculated subject to Table 503 and Section 506 of the International Building Code, 2009 Edition, may be increased by 25 Section 9. TMC Section 16.05.080, "Elevators," hereby reads as follows: 16.05.080 Elevators A. Elevators shall comply with the requirements of International Building Code, 2009 Edition. Chapter 30, and the following: 1. One elevator shall be provided for Fire Department emergency access to all floors. 2. Such elevator car shall be of a size and arrangement to accommodate a 24 -inch by 84 -inch ambulance stretcher with no less than 5 -inch radius corners in the horizontal, open position and shall be identified by the International Symbol for Emergency Medical Services (Star of Life). The symbol shall not be less than 3 inches and shall be placed inside and on both sides of the hoist way door frame. 3. An enclosed elevator lobby shall be provided at each floor. The lobby enclosure shall separate the elevator shaft enclosure doors from each floor by fire partitions as prescribed in the International Building Code, 2009 Edition, Section 709. Fire partitions shall have a fire resistance rating of not less than one hour, no exceptions permitted. 4. Doors protecting openings in the elevator lobby and enclosure walls shall also comply with the International Building Code. 2009 Edition, Section 715.4.3 as required for corridors. 5. Penetrations of the elevator lobby enclosure by ductwork and air transfer openings shall be protected as required for corridors. 6. Elevator lobbies shall have at least one means of egress complying with provisions of the International Building Code. 2009 Edition. Chapter 10. 7. As an alternative to providing elevator lobbies, the elevator shaft enclosure shall be pressurized in accordance with the International Building Code. 2009 Edition, Section 708.14.2.1 as presently constituted or hereafter amended. Section 10. TMC Section 16.05.090, "Fire Department Access," hereby reads as follows: 16.05.090 Fire Department Access Site design for any five -story Type V -A building shall include access sufficient for fire apparatus in accordance with the International Fire Code, as presently constituted or hereafter amended, and Tukwila Municipal Code Chapter 16.16, and shall be approved by the Fire Marshal. The fire apparatus access shall be described on the site plan that is submitted for a permit application. Section 11. TMC Section 16.05.100, "Attic /Roof Ventilation General Design Require- ments," hereby reads as follows: 16.05.100 Attic /Roof Ventilation General Design Requirements A. Ventilation of attic spaces shall be in accordance with the International Building Code. 2009 Edition, Section 1203 and the following condition: W: Word Processing \5 -1 Building Code BB:rnrh 3/29/2011 Page 4 of 5 1. The design of attic ventilation method shall not include eave vents or cornice vents that would occur directly above and within 36 inches horizontally of a window, whether fixed glazing or windows with vent openings. B. Construction details shall include details necessary to prevent damage from the cumulative effect of wood shrinkage as it will affect plumbing systems, electrical systems, exterior cladding and moisture control systems of the building envelope and wood structural connectors. C. All fire doors protecting exit enclosures, exit passageways, elevator lobbies or fire doors providing access through other fire rated assemblies shall be installed with magnetic hold -open devices. Doors so equipped shall be automatic closing by the activation of smoke detector or loss of power to smoke detector or hold -open device. Section 13. TMC Section 16.05.110, "Construction Inspections," hereby reads as follows: 16.05.110 Construction Inspections In addition to the construction inspections required pursuant to the International Building Code. 2009 Edition, Section 110, and special inspections required by Chapter 17, structural observation by the engineer of record shall be required for the structural frame and seismic force resisting systems. Conditions for structural observation shall be in accordance with the International Building Code, 2009 Edition, Section 1710. Section 14. TMC Section 16.05.120, "Maintenance of Fire Protection Systems," hereby reads as follows: 16.05.120 Maintenance of Fire Protection Systems The owner(s) of a five -story Type V -A building shall maintain the fire and life- safety systems required by the International Building Code. 2009 Edition. and Tukwila Municipal Code in an operable condition at all times. Unless otherwise required by the Fire Marshal, testers. approved by the Fire Department shall conduct yearly testing of such systems. A written record shall be maintained and shall be forwarded to the Fire Marshal and be available to the inspection authority. Section 15. Severability. If any section, subsection, paragraph, sentence, clause or phrase of this ordinance or its application to any person or situation should be held to be invalid or unconstitutional for any reason by a court of competent jurisdiction, such invalidity or unconstitutionality shall not affect the validity or constitutionality of the remaining portions of this ordinance or its application to any other person or situation. Section 16. Effective Date. This ordinance or a summary thereof shall be published in the official newspaper of the City, and shall take effect and be in full force five days after passage and publication as provided by law. PASSED BY THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, at a Regular Meeting thereof this 1-1 H day of Apr, L 2011. ATTEST /AUTHENTICATED: (//414/* 4 Pleti Ji ggertoOpfor Christy O'Flaherfy, CMC, City Clerk i ed with the City Clerk: 3 APPROVED AS TO FORM BY: Passed by the City Council: Published: Li 1 Effective Date: O` t� ty attorney Ordinance Number: W: Word Processing \5 -1 Building Code BB:mrh 3/29/2011 Page 5 of 5 City of Tukwila Public Notice of Ordinance Adoption for Ordinances 2326 -2331. On April 4, 2011 the City Council of the City of Tukwila, Washington, adopted the following ordinances the main points of which are summarized by title as follows: Ordinance 2326: AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, ESTABLISHING SPECIAL PROVISIONS FOR 5 -STORY TYPE V -A CONSTRUCTION, TO BE CODIFIED AT TUKWILA MUNICIPAL CODE CHAPTER 16.05, "5 -STORY TYPE V -A BUILDINGS PROVIDING FOR SEVERABILITY; AND ESTABLISHING AN EFFECTIVE DATE. Ordinance 2327: AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, UPDATING REGULATIONS REGARDING FIRE PROTECTION SYSTEMS IN NEW AND EXISTING BUILDINGS WITHIN THE CITY OF TUKWILA, AS CODIFIED AT TUKWILA MUNICIPAL CODE CHAPTER 16.42; REPEALING ORDINANCE NOS. 2050, 2130 AND 2167; PROVIDING FOR SEVERABILITY; AND ESTABLISHING AN EFFECTIVE DATE. Ordinance 2328: AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, UPDATING REGULATIONS REGARDING AUTOMATIC FIRE ALARM SYSTEMS IN NEW AND EXISTING BUILDINGS WITHIN THE CITY OF TUKWILA, AS CODIFIED AT TUKWILA MUNICIPAL CODE CHAPTER 16.40; REPEALING ORDINANCE NOS. 2051, 2131 AND 2168; PROVIDING FOR SEVERABILITY; AND ESTABLISHING AN EFFECTIVE DATE. Ordinance 2329: AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, REPEALING ORDINANCE NOS. 2053, 2083 AND 2133, AS CODIFIED AT TUKWILA MUNICIPAL CODE CHAPTER 16.48; UPDATING CERTAIN FIRE PROTECTION STANDARDS FOR THE CONSTRUCTION OF HIGH RISE BUILDINGS WITHIN THE CITY OF TUKWILA; PROVIDING FOR SEVERABILITY; AND ESTABLISHING AN EFFECTIVE DATE. Ordinance 2330: AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, ESTABLISHING NEW REGULATIONS TO BE CODIFIED AT TUKWILA MUNICIPAL CODE, CHAPTER 16.46, REGARDING CERTAIN FIRE PROTECTION STANDARDS FOR THE CONSTRUCTION OF MID -RISE BUILDINGS WITHIN THE CITY OF TUKWILA; PROVIDING FOR SEVERABILITY; AND ESTABLISHING AN EFFECTIVE DATE. Ordinance 2331: AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, AMENDING ORDINANCE NO. 2290, §8 (PART), AS CODIFIED AT TUKWILA MUNICIPAL CODE SECTION 16.16.070, "AMENDMENTS TO THE INTERNATIONAL FIRE CODE," AND AMENDING ORDINANCE NO. 2290, §13, AS CODIFIED AT TUKWILA MUNICIPAL CODE SECTION 16.16.110, "VIOLATIONS— PENALTIES," TO CLASSIFY FIRE LANE PARKING VIOLATIONS AS A CIVIL INFRACTION; PROVIDING FOR SEVERABILITY; AND ESTABLISHING AN EFFECTIVE DATE. The full text of this ordinance will be provided upon request. Christy O'Flaherty, CMC, City Clerk Published Seattle Times: April 7, 2011