HomeMy WebLinkAboutPermit D01-186 - SOUTHCENTER MALL - TALLS CAMERA - IMPROVEMENTSTALLS CAMERA 672 SOUTHCENTER MALL D01 -186 • } City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Parcel No: 262304 -9004 Address: 672 SOUTHCENTER MALL Suite No: Location: Category: ARET Type: DEVPERM Zoning: Const Type: Gas /Elec.: Units: 000 Setbacks: North: Water: N/A Wetlands: Contractor License No: ARCHIIC043C1 OCCUPANT OWNER CONTACT CONTRACTOR Permit Center Authorized Signature: DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. .0 South: .0 Sewer: N/A Slopes: N TALL'S CAMERA Phone: 672 SOUTHCENTER MALL, TUKWILA WA 98188 SOUTHCENTER JOINT VENTURE ATTN:, 25425 CENTER RIDGE RD, CLEVELAND OH 44145 JOSEPH SHING Phone: 206- 622 -4981 506 2 AV, SUITE 3300, SEATTLE WA 98104 ARCHITECTURAL INT /CNST SRV INC Phone: 253- 848 -5948 PO BOX 73397, PUYALLUP WA 98373 k*********** k****** k**l c: lr****** ******** ** * ** ** *kk ** * * * * * * *** ** * ** * * **** * * ** *•k* *•kph **** Permit Description: TENANT IMPROVEMENT TO EXISTING RETAIL SPACE INSIDE MALL BUILDING, NO STRUCTUAL CHANGE TO BUILDING SHELL AND CORE * * * * * *•k * * * * * * * * * * * * * * * *•k * *•k* *•k * * * * * * * * ** - k•k* * ** * * * *•k ** * * ** * ***•k* ** * * ** *** ** ** ** Construction Valuation: $ 30,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load:. N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N ***************************************k*** k** k**** k** * * ** * * * * ** * **k * * * *•k** * ** * *k * ** TOTAL DEVELOPMENT PERMIT FEES: $ 733.39 *********** * * * * * * * * * * * * *•k * * * * * * * * * * * ** *•k *** k********* ** * * * * * * * * * * * *•k•k ** * * * * * ** * *** I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the p pion of a t r state or local laws regulating construction or the per wo i m authorized to sign for and obtain this developmen Print Name: 0 Signature: _ R (0.1Lk &A.) Permit No: Status: Issued: Expires: Streams: Date: (206) 431 -3670 D01 -186 ISSUED 07/25/2001 01/21/2002 Occupancy: STORE UBC: 1997 Fire Protection: SPRINKLERS East: .0 West: .0 Date : 1 7 -- ff - 0/ sR,: i.:,..• �k.. 2:.. sw.: .it:,i:.i.ua.:ItLeeu::u'ta.:�'" 1.I.r: wL�::;oc.i.:.'i 4 Y - .aswti44u1e4 i:t; This permit shall" become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Address: 672 SOUTHCENTER MALL Suite: Tenant Type: DEVPERM arse l #: 262304-9004 k Xt:rk k*• k•k'k*•k•k Ar* **•k*•k*'k ; 4*• k• k• k• k• k• k• k• k• k* *•k*•k•k **• * *•k•k•k•k* k•k•k* k•k* k•k k k * 'P.ermi t Condition::. :. IT, No changer wi t l be made to the plans unless approved by the Engineer and the. Tukwi 1a ; Bu'i icing Division. Any new ceiling grid and light fixture installation is required to meet,latera'l bracing requirements for '.seismic, Zone 3. ,Partition w.a1;1 s " attached to c.ei,lina,grici must be laterally braced if ov eight (8) feet in length. All construction: to be done in c bnformar►ce with "approved, plans: and',reguirement. .of' the Uniform Buildirig Code (1997 'Edition),as amended, Uniform Mechanical Code ( 1997' Ed i t i'on) , and Washington Stated Energy Code ' (1997 E d i t i o n ) . V a l i d i t y of Permit The issuance of a permit or approval plan. speci#;ications, and Computations shall not be con - strue'd to be a. permit" 'or, or an approval of, any vio{ation at any of the p r o v i s i o n s . of the bu.•i l d i r;g code or of any other : dinance of the ,jurisdiction, No permit presuming to give authority:; to violate or cancel the Provisions of this code ha 1'i be ;valid. _. There: shall be 'no occupancy, of the bu l l d i ng t ) until 1 the final inspection has been co mple:ted, by', the Tuwi l. Building Inspector: All rire.chanic.d1'_work ,hall be `under Separate "permit issued by the {.Cit- r .‘of.'- Tu4wila. All per�nti ts. inspection record_. and nd approved plans sha? 1 be avai hart le" at • , the job site prior to the sta -•t' of any con •struction Thee document: are to be main:t,ained; acid avai 1 -; .able unt: 1 1 `1 i rail i'nsuect i on approval is " aran ted . .***FIRE :DEPARTMENT CONDITIONS*** 0. " The attached set of plans have been reviewed by The Fire Prevention' Bureau .and, are acceptable with the following concerns.: The total number of fire. extinguishers required for your establishment Is 'calculated at one extinguisher for each 3000 : q, ft, of area The extinguisher (s) should, be of the " A l l Purpose "; (2A, 1013":0, dry chemical t y p e . 'Travel distance to any "fire extinguisher must be `.75' or less. (UFPA 10, 3-1.1) 12. Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hander or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. 13. Extinguishers shall be located so as to be in plain view CITY OF TUKWILA Permit No:' D01 -1 36 Status: ISSUED Applied: 06/21 /2001 Issued: 07/25/2001 (if at all pOssible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher", wi an arrow pointing to the unit. (NFPA 10. 106.3) (UFC Standard : 40-1) Clear access to tire extinguishers is required at all times...They may not be hidden or -obstructed. (NFPA 10, 1-6.5) 5- Fire.'etinautshers require ,monthly and yearly inspections. They have a tag or label securely attached that IndLoates month and year that the inspection was performed and shall identify the company or Person perfiirmin9 'the,service (NFPA 10, 43, 4-4 and 4-4.3) Every. ix years, dry chemical and halon type fire extiiiigulshers shal I be emptied' and subjected to the appal ca ble -recharge procedure. (NFPA 10, 4-4.1) If the required monthly and yearly inspections of the f ftc extinguiiher(s) are not acComplished or the inspection tag is not complete, a reputable fire extinguisher service company will he required to conduct these required surveys. (NFPA 40, 4 4-4) Maintain, fire' • extinguisher coverage throughout. No point in an,unsprinklered building may be more than 200 feet from an 'exit, measured along the path of travel. ((ABC 3004.2.5.2:1) . No point in a sPrinkiered - building may be more than 250 feet from an :exit,;',,measured along the path of travel. (UBC 3004.2.5.2.2) " . Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. ((ABC 1003.3.1.5) 20. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable_ All locking devices shall be of an approved type. (UFC 1207.3) 1. Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) 22. When two or more exits from a story are required. exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2) 23. When two or more Pxits from a story are required and when two or more exits,..)rom a room or an area are oui red. exit signs shall be illuminated. (UBC 1003.2.8.4) 24. Internallv illuminated e. it siqns shall have both bulbs wort ing at a1..1'' imes.- ... (UBC 1003.2.8.4) _ - -- 25'. Exits shall be illuminated any time the build is occupied with l i y7'M having an intensity of nc ;less than 1 foot candle at floor level. Fixtures requirea'tor exit illumination sha l l be supplied from separate sources of power for Group 1, Division 1 , 1 and 1.2 occupancies and for all other occupancies where the exiting system serves an , occupant load of 100 or more. (UBC 1003.2 ,9, 1003.2,9. 2) a': The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of it it's failure, illumination shall be automatically provided from an emergency system for Group ti Divisions: 1:1: and 1.2 occupancies and for all other occuryanci es where the means of egress system serves an load of 100 or .more. Such emergency systems shall be irti tt:lled , in accordance with the i l'e"tric.al code. '(UBC 1003.9'42) All .exit t vigns shall be illuminated at all times. To ensure continued i l:.lun ination for, a' duration of not less than 1 1/2 ,hours in , case of:, pri many power loss, the e x i t signs shall.; also be connected to - an' emergency : electrical system provided ; .from, toraae batteries, unit equipment "c or an on site generator .'et -, and the system' shall be installed in accordance withthe electrical code (UBC 1003.2.8.5) Haintian sprinkler" coverage per N. F.P:A, 13 Addition /relocation of walls, :closets or partitions may require relocating and/or adding sprinkler heads. Sprinkler protection shall be extended to all areas where required, .including all enclosed areas, below obstructions and under overhangs greater than four feet wide, (NFPA 13-4-5,5.3.1) All new 'sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings, prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the. W.':f,R.B. , Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and/or recoryni_ed by the City of Tukwila, prior to submittal to the Tukwi la Fire Prevention Bureau. No s p r i n k l e r work s h a l l commence without approved drawings. (City Ordinance #1901) ;ii,:n Sis;x4a, ;.ti... ti:- l;n.1. , k -. n.i�.3. „a. iw1. r�X1d' iM.,+ ::'1.'xf;.ctLXk3rP�ti+r+. /..,,, ,L,'�:•i, t.+,ti sp system plansCalculatjons and tht contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212-80) 32. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls. closets or partitions may require relocating and/or adding automatic fire detectors. 1 ' 33. Maintain square foot coverage of detectors per 1 manufacturer's specifications in all areas including: closet, elevator shafts, top of stairwells, etc. (NFPA 1 , 72, 5-1.4.2) 34 All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire ; Prevention Bureau. No work shal/ commence until a firP department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 1' • 35. All electrical work and equipment shall conform strictly to I, . the standards of The 'National Electrical Code. (NFPA 70) 36. An aisle to and working space shall be provided for each ',. electrical phP1'. An aisle width not less than 24 Inches shall provide access to the panel and 30 inches of working space shall he provided directly in front of the panel. (NEC 110-16(a),' 'NEC 110-16(c)) Each circuit breaker shall he legibly marked to indicate its purpose. (NEC 110 Required fire resistive construction, including occupancy separations, separation walls, exterior walls due to location on property, fire reststive requirements based on type of constrtiction. draft stop partitions and roof coverings shall he maintained as specified in the Buildina Cod' and FirP:"Code and s6aii be properly repaired, restored "••••'..• • •" . . „.. • •••.• or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) , The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No 8-8 of the Uniform Building Code. (UBC 804.1) 40. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers .:!hall contrast with their background. (UFC 901.4.4) 41. In order to provide you with the fastest police and fire protection under emergencv c-ondltions, please pc.stvour__ i e gr-ant n s..ierni does riot presume to give author-it. o plate or ancel lie provi n:: %01 any other work or local laws: ulatiri constrj j ion 0. r for mance of work:. a°mec .suite. room or apartment number in a consp i c_:uous place near the main entry door. (LIF►; 901.4.4) 42 . F i re Department T k: boxes shall be provided access to all f ire'.alarm panels and sprinkler risers. rrie appropriate Key(s) for access shall be placed in the lockbox. Lockbox order. forms must be obtained from the Tukwila- Fire .Department. (City Ordinance #1900) . .Contact :the Tukwila Fire Prevention Bureau to witness all required' :inspections and tests. (LIFC 10.'503) (City. Ordinance #1900 and #1901) :: This' review limited to speculative. tenant. space only, pace - special fire .perm is . may to neces sary depending 'on detailed description of intended use Any. over. 'looked : hazardous condition and/or violation of • the .adopted Fire .,or. Building Code does not imply approval. of :scch..condition or vial�atton The pl,ans Were : rev i owed . bry .c53.; If you have ;any uestions, please ca. :l l '`the. Tukwila Fire Pr eventi;on Bureau t. (206) 5757440 .. ,. ereby certify- that I have read these c o n d i t i o n s and w i l l comp l y them as outlined. All pro visions of law and ordinances ,:governing aork wil :l be complied with, whether specified herein orrlot. t SL? 5�":` S? e',. h tn` Sn .�.,'i +{ai�1�i #,.�`+:. +::t.SiM +"i „` %� :t;fi� :'J'.`;� :+; }tip •,, • z: O 0 w X :: I- . N LL w 0 g LL Q: CO z C�.. w I-- O. z w U � w W S - V u. lll U CI) 0 H Project Name /Tenant: TALL I S cam Ep . Existing use: Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑ Hospital R Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Value of Construction: vvoto Site Address (include suite number) f) -1 -I es al--1 MW- - SPAC N0,5664 City State /Zip: tA:wic,4 wry 9friIQ,v Tax Pa Number: 262. ;q- 4 1e64 Property Owner: ii-ir. t2 1( 11 - i> 1'�1 .)AGa135 Grtoc(P 10,1C Will there be rack storage? ❑ yes 121 no Phone: (44o) S7 i - 4 000 Street Address: cit State /Zip: 254 25f G< 1,1 ,)2 n.l PGig ROM) C-Gte.l( l hrJ n , DU 44 14-s F x II: ( 4 00 6os -- ( ?O Contractor: Phone: Street Address: City State /Zip: Fax It: Architect: . 5111 12. 51 `4' 1,144 A, SSR:144 ,S Ph n ) 622 - 4ciel Street Address: 5 2 4V 1 sui-r, , 3w Q7, SE4 vim, City State /Zip: ° A104 Fax ( - ) 662.- 428°( Engineer: 412.nu W oo rp (4 Khz 1-14 ii A IR- al\i - 1 l,7f t (1S& PWAE L GoV►- none: 2 5'} 0 2 1-607 g1 '1_xTI-3t Street Address: City State /Zip: Fa it: YI �1 2e)- � �L f67 � Conta t Person: . 541t-K Phone: 2 22 -zIot C Street Address: 6 24,14 /a Vg., (:rp 330,0 , 5g City State /Zip: wA G l Fa • II: Fax 062- - 4 z Description of work to be done (please be specific): • t - ).)7 s 11u P1OUt.it,cftJ1 - - 1 ' D �x t5- t . [ C , ( TA►,4- SPACE 1 1 1 1 b A i m A L )3(,ttL t t-i< N a *tZlACTIA f />L C tJ fir, 6�, - rO WILpli1J Cl 5 (,c `c C‘&12--- Existing use: Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑ Hospital R Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Proposed use: ��77 Retail Cl Restaurant 71 Multi-family ❑ Warehouse 0 Hospital Church Cl Manufacturing El Motel /Hotel ❑ Office ❑ School /College/University ❑ Other _ Building Square Feet: / 3/0 existing No. of Stories: / Area of construction (sq ft): /3/0 Will there be a change of use? ❑ yes M no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 121 no Existing fire protection features: ,l sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Will there be storage of flammable /combustible hazardous material in the building? El yes no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets I 1/31)10o c1permir.eluc CITY OF TUII' Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Number: Permit Number: __10 l Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not he accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE /CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) in Channelization /Striping ❑ Curb cut /Access /Sidewalk ❑ Flood Control Zone ❑ Hauling ❑ Fire Loop /Hydrant (main to vault)#: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer It: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public 71 Water Meter /Exempt it: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp It Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. Ihis figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: c -- ,a ( —CO k Date application expires: � 2 - 2. 1— 0 Application taken by: (initials) c-'� • PLEASE SIGN BACK OF APPLICATION FORM BUILDING OWNER OR AUTHORIZED AGENT: Signature: � / X Date: ,_2/ _ j Print rani JOSS , � Ll,1l P • C , F 0 1 , � o — 4 2 % Addr 5 , �,,- b� 2 ti AV 1 Su c-s � '33o0 , 4 A ..-�, -(� .c C it tat /7 gg i P. l WA 1 G4 APPLICATION MUST tit SUBMITTED WITH tHt ti LLOWING: > ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL_ ENGINEER OR CIVIL ENGINEER • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUM 11 H) ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Forth H -13). IZusiness Declaration required (Form I1 -10). four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) fi. Location and screening of outdoor storage (change of use only) 7. Limits of clearing/grading rvith existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form 1-1 -9). ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ Vicinity Map showing location of site ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ Cr Indicate proposed construction of tenant space or addition and walls being demolished ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 999 Third Avenue, Suite 700, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect /engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND l AM AUTHORIZED TO APPLY FOR THIS PERMIT. ' •• mmotr.nrsoxtrit s , Y4,•4 • , WrIt..2 7 4 ; 11 . • • • • ' , MOS • trer • " . * #***.A . **.. - Aiivkicit ; **A 4 C ‘15,4 **k****I i ir*I4**A**Aft-hA**.A.A***11.****A******** ;ITY OF T11I<WILA.. WA • • •• • • TRANSMIT *Il ** * * fr * * .1e:A A A tir A 74 * *4** * * :V** .A* A * tit(4NS41:31•.11iirti R010 , Amount • 446.25 07/25/01 12:46 Payrnenb Method: ; CASH i4otatiOn:" IN Init: •(. • P er'3n .1 b No: D01-1436‘ :Type: 'DEVPERM DEVELOPMENT PERMIT Parcel No: 262304-9004 te':;Picii '672 SOUTHCENTER MALL. • ,., • . Total Fees: 733.39 Pavnent 446.25 'Total ALL •Pmts: 733.39 Bal ander. • 00 !i Account: Cod " Description (Amour) NONRES 441.75 .6004886:96C STATE BUILD:IWO SURCHARGE 4.50 . • • af , ; L q1‘ ..4-. ■,‘ b4t4: 4.4 • • .ty, • *k** :411,x* *4 * ** * ;%k, �41r**i ' * *** 1* ** **** *:1*k,.. *** *k* ** * * *:4:4:k:t xl OF T <UIO.IL�i41 X11.1. T. k TRoi.sm3 *-** sit** * ***:*** kk* k* 74husk * *.: t *A* * :or ;t:k * *A14.t74 A ..4**A** 4,1 N$ /11 T N i,mber. RQ1O p 795 :PI iiount: . ..287.14 06/21/01 09 38 N a t 'fm rat M4ethod r, HECK Notation :. MESHER SHINS :En; t; JrD 3 _ . erHi t No: D01 -18% ft� DEV DEVELOPMENT PERt“T: S ite fAdds : `672 SOUTHCENTER MALL ryr', Total Fens: 733..39 h is `Pav- merst' . 287.14 Total ALL ..Pmts: 287.14 L Balance: 446..25 it,41f *.+ � * y 74 *kf '* *** *** ** * ** C'* * ** � r •1 144t* * ]\ ** *It'*r *** * A 4**** 7i.* *'7. *'* **'* * uu -n ,Code .` pescription _: Amount trit d/3;45 830 . '` , FLAN CHECK - :NOivRE$ 287.14 TI16 'e, emliAoi T Inspe ion: , of P .1 A dr ss: r mi ll tim Date called: Special instructions: Cp Date wanted: VazglO1 (a.m. p.m. Request Phong; .3 _ j_0/' .. &41 Approved per applicable codes:,- - INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: 677+6 F vv4, Inspector:' — .r Date: 9-019-0 I $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: ..'` nrouAt:: 7 X fI vax '^'.::t;,ti�7i4srW..'�i' ++• ;��:,anf•z�7i�'M: ^ ;t4?�l;,Y+�� r.. w. w442 .:f.+�+.v�:.:,.w...,:r.:r �x 1 l i z a t :+. < tr •....:: «, «,w:.� :it.�.grs+tt:�• r�•;: BLS. a ,,.4.�.:.cWa'l:Gi'i} 4; stn. <yhoicx�5�ui tx Yx,+ r, l..+ ra¢ iV d� r. fla„�1. +i�h,sxw.d.t.yii::i'`r: a•J�;.`Y.v�, P ect: f C atikata, Q• Type of Inspection: Q , t �/ r C.JCJcI I Date call / Y( Address: co :), S C • lq4cAti Special instructions: . Date wante . ! Requestep (4 r1: cioq -olio NSPECTION RECORD Retain a copy with permit INSPECTION NO. . CITY: OF .TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981 ati1 /4: 145:s:tza ti0.4 S4tiF}o4 ."t,?3'.9}`ra✓wi A'.:!r:: !' :'L�u a: ��3w; `;�F.': '�iit�J,•,i.'�'.'d �i:.'�; PERMIT NO. (206)431 - 3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: /" t ) !- i-r t,Y1 2 roi �,�� e - cpro ved tr 1 t 2) )_..A 0 1 1 1'44 — fa 44 1a 1/4 4- t I Irispector`i (� 4) .,40 Date: C LS. $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Project: T- (� ' s (� . a Ty of Inspectio 3 c. � / , 1 .7 I Date call C j Special instructions: Date wanted: // cri� /4/ p.m. Requeste I Phone: (2 . \ coop -.CP `f /3 :l:. t..l.'.Lu+.it.TJii:.w.5.e ieui i..Y .ta`.rve.2:: . tlii '44 444, 4 JfZj'd7 INSPECTION RECORD. . Retain a copy with permit INSPECTION . NO. -CITY:OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981 PERMIT NO. (206)431 -3670 ‘- -J E Approved per applicable codes. Corrections required prior to approval. COMMENTS: l ] Pc Gto‘ t ry j rour,IL - pert) v6 e= 0 lc,.) 4;\ p s \4S c airy.ot . , A-Py POACthirti kiv■ Inspector: t - lf� Date: 9...[ 1 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: t '4'rSe�3 a ESa,...: } A :.sw, :st.c.: x c':, .c.:', . t sc: c n.uLm t 3 r •Z � cL Q � JU U O' .w Wz • N LL: W D ' Q N = Z F ... Z O. 2 p� U (0 W W. Ia. O .. Z W U 2 • O~ ; .z Pro ct: f , ! c� ' . � T J ('c Ili e vCam - T e of Inspectio U q . �. I I ‘ hC { Address: Date c 116d: _ _J Special , instructions: aps ,.- Nr17e CCI Cali* 4 O DO Vgil. a.m: rsr v Ph oned Q63- (o& -• (o 13 co. '.,af'.4. n°.: + \q".o'[ Approved per applicable codes. :t INSPECTION RECORD Retain a copy with permit ' INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 PERMIT NO. (206)431 -3670 r Corrections required prior to approval. COMMENTS: �..p ‘J21 I►V■ C F1 7- s A‘ p 7pk-- 6 Sc szsA3 Imo, I f Inspector: \ � � ) . Dat : C 0 $47 10 REINSPECTION FEE R QUIRED. Prior '• inspection, fee oust be paid . 630,• Southcenter Blvd., Suit- 100. Call to schedule reinspectiot Re •ipt o: Date: r t 1 Z W re UO on: J =. N u w O � Q = _ Z �. I- O Z I-' Ill au D O .0 �; ;O H W U . • - 111 Z — =! 0 z Project: Type of Inspection: Address: ' S C . pilot ii Date called ` 7 1 /t7 (Of 5�9ecial instructions: „...... '',-:) Date wanted:., `m. f0i . i m 1 f � Requester: �� -, o‘ - ).R .% ) Lexie acoc6 • INSPECTION RECORD .Retain a copy with permit :' INSPECTION NO CITY OF TUKWILA BUILDING DIVISION ;6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: ifr,-nAse) 4-7/An s / s ,m.•,r•�. G4/'/ /./ i 4/ r r° "Ze - / (7X j i 1Pf /S (9) ./D/eneos., 4 ,44/pPorer , c'e°3 / G41/.4 ,14.0„,/,/7 GlA/1. Z/ Insp ctor: ti $ 47.00 REINS ECTION FEE REQUIRED. at 6300 Southcen /er Blvd., Suite 100. C ecei t No: Corrections required prior to approval. Date: PERMIT NO. (206)431 -3670 prior to inspection, fee must be paid to schedule reinspection. Date: - ?i,f �si?y.e...i':i. 1-4 v taa d: z' = -- W re 6 JU 00 mo o. co W = . J H N LL WO II O N 0 1- W W : 2 H - ; L O U N' z INSPECTION RECORD .•. Retain a copy with permit INSPECTION NO. „ . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 Approved per applicable codes. fl Corrections required prior to approval. • . COM / Inspector: . 1 9 / Date:9,6 $47.00 REINSPECTION FiE REQUIRED. Prior to inspection, fee mus be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: • .. '10 ,',,,41A4V.+•'414,4++,'444 Type of Ins n: Address: '` pa. 1 1 Date callect? j ..,/ Special instructions: Date wanted. d , ( q_rq p.m. Requesreb P h b INSPECTION RECORD .•. Retain a copy with permit INSPECTION NO. „ . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 Approved per applicable codes. fl Corrections required prior to approval. • . COM / Inspector: . 1 9 / Date:9,6 $47.00 REINSPECTION FiE REQUIRED. Prior to inspection, fee mus be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: • .. '10 ,',,,41A4V.+•'414,4++,'444 ' 4 .i.a.41,,o.inti,"1 44-4 4' • - • project, Name i e l q e VC Address co 7 0 c)-4 - fete / Retain current inspection schedule Needs shift inspection . ' • City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT . FINAL APPROVAL FORM • Mc,/ / Permit No. no/- 6)6 Thomas P. Keefe, Fire Chief John W. Rants, Mayor • Suite # Approved without correction notice Approved with correction notice issued Sprinklers: Y Fire Alarm: Hood & Duct: 41 Halon: Monitor: 4 D Pre-Fire: Permits: Authorized • Signature . ......, 't , ; 4 11.1• 1,, Pnc* . km2 4 ; — Date FINALAPP.FRM T.F.D. Form F.P. 85 -0/ Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575•4439 Project TALLS CAMERA From Sheet _ A2i2 . SCALE: 1/4 A I FLOOR PLAN Date 0/24/01 Drawing FLOOR PLAN • — • THESE WALLS TO ENE NON-RATED WALLS STORE ROOM • I P 6 HOT NAT ER TANK ON PLATFORM ABOVE - SEE DET. 6/A2.2 1 (/4" VERIFY ALIGN FILM PROCESSING 4'-2" FURNISH 4 INSTALL NE SINK AND GONNEGT TO EXISTING PLUMBING LINE, HASTE, VENT AND HATER SYSTEM - GAP AND/OR REMOVE ALL UNUSED PLUMBING LINES 374 4 REGISTERED] ARCISIECT • 0 , • J 1 IC 511ING STATE OT WASHIUG ION NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. 15PLAY GA505 NOTE: ALL CASENORKS ARE - SLATNALL DISPLAY' 4 RASE GANNETS L. [ 1 -O 19(p. RECEIVED SEP 25 2001 BUILDING r1FPARTIVIFNT 3300 Smith Taxer Seattle. Wastington 981G4 206 622 -4981 roc. 206 662-4269 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER D01 - 186 PROJECT NAME: TALL'S CAMERA SITE ADDRESS: 672 SOUTHCENTER MALL SUITE NO X Original Plan. Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued DATE: 06 -21 -01 DEPARTMENTS: Building "Division 1-10-91 Public W rks I y C lt(G f19 .-24-0 l DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUES /THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Incomplete Comments: APPROVALS OR CORRECTIONS: (ten days) 6j1Z Fire Prevention �' Structural Approved Approved with Conditions REVIEWER'S INITIALS: CORRECTION DETERMINATION: WRROUTL.000 srri Planning ivision t -11, Permit Coordinator DUE DATE: 06-26-01 Not Applicable No further Review Required DUE DATE 07-24 -01 PERMIT COORD COPY DATE: Not Approved (attach comments) DATE: DUE DATE Approved I Approved with Conditions n Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: ACTIVITY NUMBER D01 -186 PROJECT NAME: TALL'S CAMERA SITE ADDRESS: 672 SOUTHCENTER MALL SUITE NO: X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued DATE: 06 -21 -01 DEPARTMENTS: Building Division Public Works Complete Incomplete TUES /THURS ROUTING: Approved WRROUT [.DOC srr� REVIEWER'S INITIALS: CORRECTION DETERMINATION: PLAN REVIEW /ROUTING SLIP • Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Please Route LJ Structural R w Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions Approved with Conditions REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE 07 -24 -01 n DUE DATE: 06-26-01 Not Applicable n Comments: No further Review Required n DATE: ( — ZOO Not Approved (atta h corn ents) DATE: DUE DATE Not Approved (attach comments) DATE: PERMITNO.:D l ' - VO BUILDING PERMITS INSPECTIONS ❑ 00001 Progress Inspection Status ❑ 0000 Pre- construction ❑ 00003 Investigation ❑ 011004 OK to Occupy ❑ 00005 Remove Slop Work Order ❑ 011006 Follow -up ❑ 00007 Pre -Move Inspection ❑ 00050 WSEC Residential ❑ 00060 -WA Ventilation /Indoor AQC ❑ 00071) NLEA Inspection /Modular Struct ❑ 00071 Mobile I tome Tie Down Insp ❑ 00072 Marriage Lines ❑ 00090 Rested ❑ 00095 Pooling Drains ❑ 00100 Foundation footings ❑ 00200 Foundation Walls ❑ 00250 Foundation Insulation ❑ 00300 Concrete Slab /Slab Insulation ❑ 00350 Crawl Space ❑ 00400 Shear Wall Nailing ❑ 00450 Plywood Wall Sheathing ❑ 00501) Roof Sheathing Nailing ❑ 00525 Plywood Deck Nailing ❑ 00550 Exterior Wall Sheathing ❑ 00601) Masonry Chimney ❑ : 00610 Chimney Installation /AII 'types 1)1)700 Framing 00750 Roof /Ceiling Insulation ❑ (10800 Floor Insulation ❑ 00801 Wall Insulation ❑ 0080 Exterior Roof Insulation ❑ 00803 Glazing Inspection ❑ 00815 Lighting and Controls 00900 Suspended Ceiling 0101)0 Interior Wallboard Fastening ❑ 01001 Exterior Wallboard Fastening ❑ 01 110 Pre -Move Inspection ❑ 01 1 15 Motor Inspection ❑ 01120 Pre -Demo ❑ 01140 Pre- reroof 479( 01400 Final -Fire 01700 Final- Building ❑ 01900 Final- Rerool' ❑ 03100 Site Visit ❑ 04000 Special- Concrete ❑ 04001 Special -Bolts in Concrete ❑ 04001 Special- Mom /Resist Cone Frame ❑ 04003 Special -Reinf Steel Prestress ❑ 04004 Special- Welding ❑ 04005 Special-I ligh-Strength Bolting ❑ 04006 Special - Structural Masonry ❑ 04007 Special- Rcinf(iypsum Concrete ❑ (40(18 Special- Insulating Cone Fill ❑ 0-1009 Special -Spray fireproofing ❑ 1)4011) Special- Piling, Piers, Caissons ❑ 04011 Special- Shoterete ❑ 1401 Special - Grading, Exeav /Fill ❑ 041)13 Special- Retaining Wall ❑ 114014 Special - Panels ❑ 04015 Special -Smoke Control System TENANT NAME: T Couvverb 0019 Date: Date: CONDITIONS I100I No changes to plans unless approved by Bldg Div ❑ 111111) Special inspection required, notify Bldg Div ❑ 001 I Special inspector shall submit final signed report 111113 New ceiling grid & light fixture shall meet lateral bracing 0 0(113 0 Partition walls attached to ceiling grid ❑ 014 Readily accessible access to roof mounted equipment ❑ 00I5 Engineered truss drawings & calcs shall be on site ❑ (H) I6 Exposed insulation hacking material ❑ 01117 Subgrude preparation including drainage. excavation ❑ 111118 Statement from rooting contractor verifying tire retardant class of roof All construction to he done in conformance w /approved plans "No work shall be done in addition to those modifications..." 11111)3 Plumbing permits shall be obtained through King Co 0021) Structural observation shall he provided for this project 11021 All litod preparation establishments must have King Co 0023 Fire retardant treated wood shall have (lame spread of 0023 Notify 1uilding Division prior to placing any concrete 11025 All spray applied fireproofing shall be special inspected 0025 All wood to remain in placed concrete shall he treated 0026 All structural masonry shall be special inspected (11)27 Validity of Permit 0028 Rack storage requires separate permit ❑ 11111)3 Electrical permits obtained through L & I ( 11131) No occupancy 0l building until final insp by tilde Div ❑ 0032 Remove all weeds, concrete, stone foundations, flat concrete ❑ 0036 Manufacturers installation instructions required on site ❑ " 0 B I maximum allowed per 1997 WA State Energy Code" ❑ 35 Contact PW Div to obtain insp for water /sewer connect ❑ 0038 A C of 0 will be required for this permit ❑ 0039 Final approval for all 'I'I who the limits ul'the SC Mall 0004 All mechanical work shall be under separate permit .11) All construction noise to be in compliance with 8.2 'ITIC ❑ ❑ 00 Ventilation is required titr all new rooms & spaces L 005 All permits, insp records & approved plans available ❑ 0 110116 All structural concrete shall he special inspected ❑ "Applicant shall obtain a separate plumbing permit lion( King Co" "Anchoring — All new construct and substantial improvement shall he anchored to prevent flotation" ❑ 111)07 All structural welding shall be done by WABO certified inspector ❑ 0008 All high - strength bolting shall he special inspected ❑ 111111') Bolts installed in concrete shall he special inspected ❑ 1)031 Comply with requirements of l'MC 16.04 ❑ (1031 Removal of septic tanks require approval and compliance with King Co I lealth Dept. ❑ "Obtain required inspections from appropriate water & sewer districts" ❑ "Fuel burning appliances ❑ "Appliances, which generate...... ❑ "Water healer shall he anchored...." ❑ "lieroot— ACTIVITY NUMBER D01 -186 DATE: 06 -21 -01 PROJECT NAME: TALUS CAMERA SITE ADDRESS: 672 SOUTHCENTER MALL SUITE NO: X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Comments: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved REVIEWER'S INITIAL CORRECTION DETERMINATION: Approved n REVIEWER'S INITIALS: TRROMF.00c srr, PLAN REVIEW /ROUTING SLIP n Structural Incomplete Structural Review Required CI Fire Prevention I Planning Division Permit Coordinator DUE DATE: 06-26-01 Not Applicable No further Review Required DUE DATE 07 -24 -01 Approved w' h Conditions Not Approved (attach comments) S: DATE: V> 6 / Approved with Conditions n Not Approved (attach comments) DUE DATE DATE: ACTIVITY NUMBER D01 -186 X Original Plan Submittal DATE: 06 -21 -01 PROJECT NAME: TALL'S CAMERA SITE ADDRESS: 672 SOUTHCENTER MALL SUITE NO: Response to Incomplete Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued DEPARTMENTS: Building Division Public Works n PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUES /THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved CORRECTION DETERMINATION: Approved Approved with Conditions REVIEWER'S INITIALS: Y'RROUK.000 SYYI Incomplete ri Planning Division Permit Coordinator DUE DATE: 06-26-01 Not Applicable ri Comments: No further Review Required *\e DATE: (0 DUE DATE 07 -24 -01 Approved with Conditions ri Not Approved (attach comments) REVIEWER'S INITIALS: DATE: DUE DATE Not Approved (attach comments) n DATE: DEPARTMENTS: Building Division Public Works PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER D01 -186 DATE: 06 -21 -01 PROJECT NAME: TALUS CAMERA SITE ADDRESS: 672 SOUTHCENTER MALL SUITE NO: X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES /THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved ri Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: Approved n Approved with Conditions REVIEWER'S INITIALS: Y'NItOUILUOC 5199 Incomplete Planning Division Permit Coordinator DUE DATE: 06 -26 -01 Not Applicable No further Review Required DATE: (2 DUE DATE 07 -24 -01 DUE DATE I I Not Approved (attach comments) DATE: z w L re J U O 0 CO O W= CO W w 2 gQ = a I- w Z = �- Z F- • w O • D w I-- • U - ~ .. w z U CI) H _ O f . z REGISTERED AS. PROVIDED BY LAW AS -CONST CONT GENERAL REGIST. # EXP. DATE CCO1 ARCHIIC043C1 09/24/2001 EFFECTIVE DATE 02/21/1996 ARCHITECTURAL INT /CNST SRV INC PO BOX 73397/ PUYALLT.IP WA 98373 7 Sic:luzure , 'j: i SiiCL'. by D'EP R ;,; 4:: 4 ti . l..A.5 . ' 1 IN L„ 5T FS eed Current Contractor Registration Card: eed to Enter Contractor Information in Sierra: I � v.:; >•�:.«,;.t . , o ;: �� ;. c` . �:�tx! " > " � ni a � > � � >: . �r...��d��� ota t i "t Y:�.'3i4=�C`ii�,LVi.�$�tr'•d 7,n1'as'<� `*d•,'. ^.ky," �.7K.`s3�i:..� -a 3?., flhsf .lafil�it� « ;z Z _ 1- • W r4 2 6 .J U o U U: w J I- LL L11 o' ZE LL. Q d 1- W. Z �.. 1- O: Z 1: LLJ U ' :O U) o w w': = o: z CD - _. 0 . . . 00 c : 4:2; ez/e. 4- 7_ -,. 1 eed Current Contractor Registration Card: eed to Enter Contractor Information in Sierra: I � v.:; >•�:.«,;.t . , o ;: �� ;. c` . �:�tx! " > " � ni a � > � � >: . �r...��d��� ota t i "t Y:�.'3i4=�C`ii�,LVi.�$�tr'•d 7,n1'as'<� `*d•,'. ^.ky," �.7K.`s3�i:..� -a 3?., flhsf .lafil�it� « ;z Z _ 1- • W r4 2 6 .J U o U U: w J I- LL L11 o' ZE LL. Q d 1- W. Z �.. 1- O: Z 1: LLJ U ' :O U) o w w': = o: z CD - _. 0 I I I I II !I II J 66' m Q CD p a rn T ,r -n _ �l"a 0 6"6 �o �y$vv ovv�v � mm $ ro g v i UU i 1 E � � � � X a a 1 s t `n NI ' F ,3 ,! n b b b o r z b b a 3 y ijflij O 2 TT Ti . O O O 3 U gs rn N 0 0 00 0 a l i p 1 $, m ip 4 " f r i - — _ o AN gil l K A 1 (W. T� � �O ON� v��s 41 s Z 1 N s ftp c i 1 k1 a 0 8x le 4R Pi d! r i w ° ?A" d a 1'' 4 11i4 ii; 43 10_ it _ 4 ip6 it ill " Job Title v ANIMISM iMMINIIMIMI! 1 v i z d b b t r • C� N - O A Op r P N ? W Al - G) O X z S C I gOO 3 $s Ag S@ ,ry g Oz tO !!!��� 2 -Si; Ag b � 11111I CD�[11YF Z mx ptg 0� i,llf S "4' i m p f i n .T t T s z 49 .r 1 Ew 0 a ,l m v i i= p � H U it M ° > T p(L Pt ,! gi t! 1 I I; 1 Y 1 114 41 A 2i 04 6 1 d 2 0'0 - k§ iri - R 1 h %X $ 1 t 0 I v o 6 Tails Camera Southcenter Space F -664 Tukwila, Washington c rIMPMF TI lgillifCgif , R O Sheet Content COVER SHEET Mgg CD F cr 4 EH A z AD � a ditr g Revision PERMIT SET - 6420/OI 0 A 0 3745 �_— — 35 Job Number Checked By AR Drawn By --1 70 n z 0 rn 70 co I- REWIRED ARCHITECT _cult K. THING SIKH OF WASHINGTON SOUTHCENTER PARKW 6 -20 -OI Date m - a ANDOVER PARK WEST CO 'O 7 i co G o PARK EAST 6 ti b O T o T I pi. z Yo- ir pr _ A U� c�� O A m ip N g o YYY � wy �' D �i N rn % 2,4 O $ g,e. rn f R 3300 Smith Tower Seattle, Washington 98104 206 622 -4981 Fax- 206 682 -4289 MESHER SHING& ASSOCIATES ARCHITECTURE SPACEoP LAN NING AND a COMMERCIAL INTERIOR a DESIGN BUILDING PERMIT INFORMATION In order to obtain a Building Permit from the City of Seattle, the following procedure will be required: Applications for building permits are submitted to the Department of Community Development. Upon receipt, plans are routed to the City's plan checker and if appropriate to the Fire Department, Planning Division, and Public 'A" :,s Department. The following documents are required: 1. A completed building permit application form. 2. Two (2) copies of working drawings, to include, but not limited to, the following: a. Site plan b. Overall building plan c. Floor plan of TENANT space d. Construction details 3. Plan Review Fee to be paid at time of application. City of Tukwila Building Division 6300 Southcenter Blvd. Tukwila, WA 98188, Tel: 2061431 -3670 FOOD & RESTAURANTS Food handling or restaurant type TENANTS shall submit two (2) sets of plans to: Seattle -King County Departmentof Public Health 201 Smith Tower Seattle, WA 98104, Tel: 206/296.4787 Attn: Joe Makelerny Requirements of a food service are detailed ih the Seattle or King County Food Code. For a copy of the Food Code contact your District Office. SPRINKLER DRWG. REQUIREMENT Prior to the fabrication of TENANT'S sprinkler system, TENANT's sprinkler contractor shall submit seven (7) blue line prints of shop drawings to the following for approval: Factory Mutual Insurance Great Lakes Operation - Cleveland 24950 Great Northern CorporateiCenter Suite 201 North Olmstead, OH 440705319i Upon approval TENANT shall forward four (4) sets of black line (preferably) or blue line prints of th0 approved design bearing FACTORY MUTUAL'S approval stamp to LANDLORD'S Tenant Codrdinator for LANDLORD'S approval and records as required in Exhibit C. UTILITY COMPANIES & SERVICES Contact the following utility company representatives for information concerning local installation requirements, application for service, billing procedures, etc.: ELECTRIC SERVICE Puget Sound Light & Power 600 116th NE Bellevue, WA Tel: 800/962 -9498 or 206/455-5120 GAS SERVICE Washington Natural Gas Company 815 Mercer Street Seatt:e, WA 98111 Service /Billing: Tel: 20614641999 Installation: Tel: 800/999 -4964 TELEPHONE SERVICE U.S. West Communication P.O. Box 12480 Seattle, WA 98191.0001, Tel: 206/346.8500 WATER SERVICE City of Tukwila City Nall 6200 South Center Blvd. Tukwila, WA 98188, Tel: 2061433 -1849 ROOF CONTRACTOR Any and all roof work must be completed by the LANDLORD'S approved roofing contractors: Cascade Roofing 6308 212th SW Lynnwood, WA 98036 Attn: Chris Smith, Tel: 206/464-0441 CONTACT INFORMATION TENANT TALL 'S CAM , 10C FIRM FFRUCw TALL CONTACT - _.._ -..- 3415 SOUTH 110 TO OI EPT vu :Tn 1C9 TUpvji:.4 WAStil 8916 STATE ZIP EXPANSION: Brills Roofing 500 Grade Street Kelso, WA 98624, Tel: 206/577 -0585 STRUCTURAL FLOOR ENGINEER Andersen Bjornstad Kane Jacobs • Inc. 800 Fifth Avenue Suite 3800 Seattle, WA 98104 -3103 Tel: 206/340-2255 Fax: 206/340 -2266 SPRINKLER CONTRACTOR Crown Fire Protection (formerly Able Fire) 4932 Pioneer Pool Bothell, WA 98012, Tel: 481 - 7669 PRECONSTRUCTION MEETItt G A minimum of five. (5) days prior to starting construction, the CONTRACTOR shall contact the SHOPPING CENTER OFFICE to arrange a Preconstruction Meeting. Attendees should include at least the GENERAL CONTRACTOR, Superintendent and major Sub - contractors to be used in the construction. At the Preconstruction Meeting the GENERAL CONTRACTOR shall provide the following: • Building Permit - A copy of each of the Local and State Building permits. • Workers Compensation Certificate. • Insurance Certificate - The Certificate of Insurance should be in the minimum amount of $2,000,000 in the aggregate, $1,000,000 each occurrence and should reflect the following as 'Additional Insureds': The Richard E. Jacobs Group, Inc. Southcenter Joint Venture JG Shopping Center Mgmt. LLC • Performance, Labor and Material Bond as required. • Sub - contractors List - setting forth the name, address and telephone numbers of Tenant's General Contractor and Sub - contractors. CONSTRUCTION DEPOSIT The CONTRACTOR will be required to provide a $1,500 company check, certified check or money order payable to: Southcenter Joint Venture Please have your Federal I.D. number ready and available. The deposit or any portion thereof may be applied by the LANDLORD as a reimbursement for materials issued to or services performed directly for the CONTRACTOR, including LANDLORD's correction of punch list items not corrected by the CONTRACTOR (see below). The DEPOSITOR agrees such deposit or any portion thereof, without prejudice is any other remedy which LANDLORD may have, may be applied as a reimbursement to the LANDLORD for materials issued to and /or for services performed directly for TENANT'S CONTRACTOR (which services may include the correction of punch list items and /or for the repair/ replacement of property damaged by TENANT'S CONTRACTOR). The deposit or any then remaining balance thereof (less a 15% administration fee) will be returned to the DEPOSITOR, without interest, within thirty (30) days after the completion of TENANT'S construction obligations as required in the LEASE. ON -SITE DOCUMENTATION The CONTRACTOR will keep the following documents on -site during construction: • Working drawings. The GENERAL CONTRACTOR will build from ONE set of drawings incorporating LANDLORD'S approval comments into the BUILDING DEPARTMENT STAMPED APPROVED SET. This set of drawings will be the primary working drawings and displayed at all times during construction. • A complete set of Typical Tenant Drawings and a set of working drawings bearing LANDLORD'S stamp of approval. • A copy of the Letter of Authorization for Access (issued by mall representative at Pre - construction Meeting.) • LANDLORD'S Construction Manual issued to CONTRACTOR at the Preconstruction Meeting. TENANT'S ARCHITECT McSTICK Ou!Nfi 4t ASSoeIA FIRM - -" JOSEPH SRiNo CONTACT 50(o SECO AVENUE SUITE 3300 ADDRESS S UJASt-ilN6TON aSICf T CONSTRUCTION REQUIREMENTS RONA The following Rules govern construction on LANDLORD'S property. All references to "CONTRACTOR" shall mean the GENERAL CONTRACTOR or the TENANT if acting as its own contractor. All references to LANDLORD may equally mean the MALL REPRESENTATIVE at the shopping center, if appropriate. ASBESTOS MATERIALS In the event TENANT'S construction encounters any asbestos containing materials (ACM), TENANT shall immediately cease construction for that part of the Work which may disturb the ACM and contact LANDLORD'S Representative at the Shopping Center to resolve how to proceed. The installation of any materials that contain asbestos is strictly prohibited, EXISTING CONDITIONS It shall be TENANT'S responsibility to verify all existing construction and equipment and subject to LANDLORD'S written approval to upgrade or replace same to comply with the more stringent of: 1) governing building codes, 2) the Federal Occupational Safety and Health Act (OSHA) and regulations promulgated thereunder, 3) all laws, ordinances and regulations of applicable State, City and Local health departments and utility companies, 4) the requirements of LANDLORD'S fire and casualty insurer, or 5) the provisions of the lease. All costs shall be at TENANT'S expense. PROTECTION OF PROPERTY The CONTRACTOR shall be responsible for protecting the LANDLORD'S and any other party's property from damage. Use of fuel operated engines inside the Mall and /or space will not be permitted. FIRE EXTINGUISHERS The CONTRACTOR shall provide adequate fire extinguishers within the premises, tagged for date of inspection, while under construction. SITE ACCESS & PARKING Specific areas will be designated by the LANDLORD for parking. The CONTRACTOR shall be responsible to ensure that all construction employees working in the premises use the designated parking areas. There will be no construction trailers allowed on the property. Parking will not be permitted in any of the driveways, fire lanes and truck docks except for temporary loading and unloading, as approved by the LANDLORD. DELIVERY OF MATERIALS The CONTRACTOR shall be responsible to coordinate all material deliveries to the premises, whether for construction, fixturing or merchandising. All deliveries shall be made through the rear door of the premises either via the adjacent service corridor or truck dock area. Contact the LANDLORD prior to the delivery of materials and equipment which are too large to enter through the rear door of the Premises. Any such items are to be delivered during NON- Shopping Center hours. Where there is no rear door to access space, all deliveries, trash removal, etc., must be coordinated before or after Mail operating hours, according to LANDLORD'S direction. NO exceptions. WORK AREA & STORAGE The CONTRACTOR'S work area will be restricted to the Tenant's leased premises. Service and fire corridors and truck docks shall be kept clear of all materials, equipment, debris and trash at all times. SECURITY & AFTER HOURS WORK The CONTRACTOR must receive the prior permission of the LANDLORD for work after normal working hours. LANDLORD INSPECTIONS The Tenant's construction work will be observed periodically by the LANDLORD to verify that the work is being constructed as set forth in the Tenant's Lease, Tenant Manual, Typical Tenant Drawings, Landlord approved Tenant Drawings and LANDLORD'S Construction Manual. SAFETY The CONTRACTOR shall be responsible to ensure that all work is performed in accordance with O.S.H.A. standards. The LANDLORD may, without any liability therefore, stop work that is in violation of O.S.H.A. standards or which may, in the Landlord's opinion, cause injury or harm to persons or property. CONTRACTOR must obtain a written permit from the Mall office prior to any "hot" work lex: welding, solder- ing, torch -work, etc.). It shall be the duty and responsi- bility of the CONTRACTOR performing any cutting or TENANT'S ENGINEER FIRM CONTACT ADDRESS welding to comply with the safety provisions of the National Fire Protection Association's National Fire Codes pertaining to such work and the CONTRAC- TOR shall be responsible for all damages resulting from a failure to so comply. TEMPORARY POWER Temporary electric power will be made accessible for those Tenants where permanent power is not yet available. Where permanent power is available, it is the responsibility of the CONTRACTOR to provide the necessary equipment to supply the electrical power needed for construction. Permanent power should be ascertained as soon as possible. TEMPORARY WATER Contact the LANDLORD for coordination of temporary water service. UTILITY CHANGEOVER CONTRACTOR shall be responsible for changeover of utilities to CONTRACTOR and/or TENANT Account as soon as possible. TEMPORARY TOILET It will be the responsibility of the CONTRACTOR to provide adequate toilet facilities for all employees working within the premises. The shopping center toilet facilities will not be available for contractors use unless specifically authorized by the LANDLORD. The location fora temporary portable type toilet facility must be approved by the LANDLORD prior to its placement. TEMPORARY BARRICADE Prior to beginning any construction, the CONTRACTOR shall ensure, if required by the LANDLORD, that a temporary barricade is installed at the storefront (see Shopping Center Manager for barricade drawings and details). Where a barricade has been erected by LANDLORD using pre- formed panels, the LANDLORD shall extend the barricade past the lease line to accommodate the storefront work. The barricade shall not be extended until storefront work actually begins, shall not unreasonably obstruct mall traffic, and shall not be more than four feet (4') past the storefront lease line. All barricades shall be extended or constructed during the non - operating hours of the shopping center. No barricades shall be removed or dismantled without express written consent of the LANDLORD. Any barricade removed without prior consent will be reconstructed by the LANDLORD at the CONTRACTOR'S expense. CONSTRUCTION SIGNAGE The CONTRACTOR is not allowed to post any company name or sign on the temporary barricade. The CONTRACTOR shall post all signage as required by mall representative for public safety or general warning. BELOW GRADE CONSTRUCTION Prior to beginning any below grade construction and under slab confined spaces the Contractor must: • Prior to Locating Floor Penetrations, Tenant's Contractor must secure LANDLORD'S structural floor engineer's approval, see address this sheet • Meet hazardous confined space requirements. • Inform LANDLORD of the work to be undertaken and receive approval of same. • Submit ALL construction materials proposed for under slab installation to LANDLORD'S representative for approval. Once the approvals have been received and under slab construction commences the CONTRACTOR must photograph the installation in detail, both in progress and once completed, and submit copies of all photographs to LANDLORD. Any Below Grade construction must be inspected by LANDLORD prior to backfilling. CONCRETE Concrete most be saw -cut or core - drilled (no jack - hammering or breaking of concrete is permitted). Secure structural floor engineer's approval prior to reforming all floor work. Prior approval must be obtained from LANDLORD prior to penetrating any structural or structurally reinforced concrete. SPRAY PAINTING Spraying of finishes or paint must ohly be done if Mali HVAC and adjacent Tenant HVAC systems are either shut down or protected to avoid contamination. MALL CONTACT NAME Southcenter Mall 633 Southcenter Seattle, WA 944116-11160 Tel: 206/246 -0423 Fax: 206/2448607 INTERRUPTION OF UTILITIES The CONTRACTOR must receive the LANDLORD'S approval at least three (3) days prior to any modification to utility services that may temporarily interrupt such service to other tenants or the shopping center. NOISY CONSTRUCTION The LANDLORD has established working hours when the ccitractor may perform "noisy" construction (i.e. saw citing, core drilling, "Hilti" type fastener guns, etc.).;ontact the LANDLORD for restricted hours. LANDLORD reserves the sole right to request that CONTRCTOR reschedule any activities deemed disruptive toestricted hours. TRASH tEMOVAL & DUMPSTERS Trash Remval - All trash will be confined to the premises an removed at the end of each day by the CONTRACbR. Any trash found in the service corridors, adjacent tersnt units, and /or other public areas will be removed bythe LANDLORD and deducted from the CONTRAC deposit or billed to the TENANT. The locatiorof the CONTRACTOR'S dumpster will be determined ry the LANDLORD. LANDLORCS dumpsters and /or compactors are not to be used ty CONTRACTOR. SPRINK.ER DRAIN -DOWN The CONTFACTOR shall seek the LANDLORD'S prior approvtl at least two (2) days in advance of needing to vain the shopping center sprinkler system. No shoppinccenter sprinkler system will be left drained oversight. All systems krill be charged and operational when the CONTRACTOR leaves for the night. A $75 fee will be charged for each time the LANDLORD'S sprinkler system is drained orshut down to accommodate connection and testing requirements. ROOF &BUILDING MODIFICATIONS The CONTRACTOR will not be allowed to penetrate the roof or adjus: or modify the LANDLORD'S sprinkler system, fixtures, utilities, structure, equipment or facilities without the LANDLORD'S express written consent and will be doneey the LANDLORD'S original contractor (or LANDLORD'S designee) at the CONTRACTOR'S expense. OPERATING WHILE REMODELING In addition to any prior stated requirements, the following rules apply to stores remaining open during remodeling. PRECONSTRUCTION MEETING For stores remaining open during construction, The Store Manater must be present at the Preconstruction Meeting to dscuss plans for the remodel, time span of remodel anc related safety issues. BARRICADE . The CONTFACTOR will be required to schedule the construction n phases and provide a phasing barricade plan indicating where the barricade will be placed. SECURITY & AFTER HOURS WORK The CONTRACTOR must receive prior permission of the LANDLCRD for work after normal working hours. In addition, the Store Manager and the CONTRACTOR must prepare for and indicate whether a Security Officer or other service is needed. The LANDLORD will not bc. responsible for the security of the CONTRACTOR'S or the TENANT'S property. SAFETY TENANT COORDINATOR AMMIIMIMIRIRIMARIIRRIMMEMME In addition to the O.S.H.A. safety standards referenced previously, the Store Manager and CONTRACTOR must observe the following: • Provide a tninimum of a four foot (4') barricade around all construction areas. • Apply plastic sheeting from the barricade up to the ceiling so as to minimize dust and related damage to merchandise, customers and the public mall areas. • Verify that all workman's tools, ladders, and loose construction supplies are out of the customers, and specifically, children's reach. • Verify that any overhead dangling light fixtures, conduits, etc. are well within the confines of the barricaded and plastic sheeted areas. • Verify that the store has down -sized its stock properly so as to remain open for business and still accommodate clear fire exits through both the rear and the front of the store. • If there is any storefront remodeling required, the CONTRACTOR will be required to erect a barricade per the above details. Tel: 4401808- NAME The Richard E. Jacobs Group, Inc. 25425 Center Ridge Road Cleveland, OH 4414541ZZ Tel: 440/871 -4800 Fax: 440/808 -6909 OPENING REQUIREMENTS • Certificate of Occupancy: The CONTRACTOR shall provide the LANDLORD with a copy of the Occupancy Permit. • Certified Tenant Air Balance Report • Punch List: Upon completion of construction and PRIOR TO opening, the CONTRACTOR shall request that the LANDLORD conduct a final observation and compile a punch list. The premises will be allowed to open for business only after the LANDLORD has received a copy of the Occupancy Permit and the punch list items have been satisfactorily completed. LIEN WAIVERS & AFFIDAVITS The CONTRACTOR will be required to submit the following items at the end of the construction (forms are available from the LANDLORD): • An original notarized "General Contractor's Affidavit and Final Waiver of Lien ". • The original signed and notarized "Subcontractor's Affidavit and Waiver of Lien" for each contractor. 27 SOUTHCENTER TYPICAL TENANT GUIDELINES TTG -Q 1 TALL'S CAMERA DBA THIS SHEET MUST BE INCLUDED AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, LOCAL AUTHORITIES HAVING JURISDICTION AND BIDDING CONTRACTORS The Richard E. Jacobs Grtiur NOVEMBER 1999 SEATTLE, WASHINGTON F664 UNIT NUMBER REVISIONS DATE: JOB NUMBER: DATE' DRAWING NUMBER: TT -01 DRAWING SUBMISSION & REVIEW CHECKLIST TENANT'S SUBMISSION CHECKLIST ' TENANT'S drawing submission must include four (4) sets of black line (preferably) or blue line prints. PRELIMINARY CONCEPT: WORKING DRAWINGS: • Storefront Elevation (with sign) Working Drawings must be • Storefront Section(s) submitted in the following order: • Details at Neutral Pier(s) • LANDLORD'S TTG -01 Sheet • Details at LANDLORD'S Soffit • Architectural • Floor Plan • Electrical • Reflected Ceiling Plan • LANDLORD'S TTE Sheet(s) • Interior Elevations • Plumbing • Longitudinal Section • HVAC • Material Sample Board • LANDLORD'S TTM Sheet(s) • Photo of Similar Store • (other drawings) LANDLORD'S REVIEW CHECKLIST DRAWING FOR CONSTRUCTION (INCLUDE APPROVE RESUBMISSION) PRELIMINARY ARCHITECTURAL ELECTRICAL 'PLUMBING HVAC NOTES: RESUBMISSIONS: TENANT shall resubmit drawings within ten (10) days. All resubmission shall be COMPLETE sets with four (4) sets of black line (preferably) or blue line prints. SIGN: This review does not include final approval of TENANT'S sign. Prior to fabrication& installation of TENANT'S sign, TENANT'S sign fabricator (sign company) shall submit three (3) sets of shop drawings to LANDLORD for approval. CHANGES: Once approved by LANDLORD, no changes shall be made in TENANT'S Drawings except upon the PRIOR written consent of the LANDLORD. AS- BUILTS: Within thirty (30) days after the opening of the Premises, TENANT shall submit a complete set of as -built drawings to LANDLORD. THIS AREA FOR LANDLORD USE ONLY.,. 0 I I ( NOTE: DRAWINGS WITH I IN THE LOWER RIGHT HAND CORNER ARE APPROVED BY LANDLORD LANDLORD'S approval of TENANT'S Drawings is contingent upon TENANT'S compliance with LANDLORD'S comments and shall not be construed so as to hold LANDLORD liable for either the architectural and engi- neering design of the Premises or the accuracy of the information contained in TENANT'S Drawings. Should any conflict arise between any of TENANT'S Drawings and the Lease, the applicable portion(s) of the Lease shall be determinative. LANDLORD'S approval of TENANT'S Drawings will in no way alter, amend or waive the requirements or criteria of the Lease. BUILDING PERMIT INFORMATION In order to obtain a Building Permit from the City of Seattle, the following procedure will be required: Applications for building permits are submitted to the Department of Community Development. Upon receipt, plans are routed to the City's plan checker and if appropriate to the Fire Department, Planning Division, and Public 'A" :,s Department. The following documents are required: 1. A completed building permit application form. 2. Two (2) copies of working drawings, to include, but not limited to, the following: a. Site plan b. Overall building plan c. Floor plan of TENANT space d. Construction details 3. Plan Review Fee to be paid at time of application. City of Tukwila Building Division 6300 Southcenter Blvd. Tukwila, WA 98188, Tel: 2061431 -3670 FOOD & RESTAURANTS Food handling or restaurant type TENANTS shall submit two (2) sets of plans to: Seattle -King County Departmentof Public Health 201 Smith Tower Seattle, WA 98104, Tel: 206/296.4787 Attn: Joe Makelerny Requirements of a food service are detailed ih the Seattle or King County Food Code. For a copy of the Food Code contact your District Office. SPRINKLER DRWG. REQUIREMENT Prior to the fabrication of TENANT'S sprinkler system, TENANT's sprinkler contractor shall submit seven (7) blue line prints of shop drawings to the following for approval: Factory Mutual Insurance Great Lakes Operation - Cleveland 24950 Great Northern CorporateiCenter Suite 201 North Olmstead, OH 440705319i Upon approval TENANT shall forward four (4) sets of black line (preferably) or blue line prints of th0 approved design bearing FACTORY MUTUAL'S approval stamp to LANDLORD'S Tenant Codrdinator for LANDLORD'S approval and records as required in Exhibit C. UTILITY COMPANIES & SERVICES Contact the following utility company representatives for information concerning local installation requirements, application for service, billing procedures, etc.: ELECTRIC SERVICE Puget Sound Light & Power 600 116th NE Bellevue, WA Tel: 800/962 -9498 or 206/455-5120 GAS SERVICE Washington Natural Gas Company 815 Mercer Street Seatt:e, WA 98111 Service /Billing: Tel: 20614641999 Installation: Tel: 800/999 -4964 TELEPHONE SERVICE U.S. West Communication P.O. Box 12480 Seattle, WA 98191.0001, Tel: 206/346.8500 WATER SERVICE City of Tukwila City Nall 6200 South Center Blvd. Tukwila, WA 98188, Tel: 2061433 -1849 ROOF CONTRACTOR Any and all roof work must be completed by the LANDLORD'S approved roofing contractors: Cascade Roofing 6308 212th SW Lynnwood, WA 98036 Attn: Chris Smith, Tel: 206/464-0441 CONTACT INFORMATION TENANT TALL 'S CAM , 10C FIRM FFRUCw TALL CONTACT - _.._ -..- 3415 SOUTH 110 TO OI EPT vu :Tn 1C9 TUpvji:.4 WAStil 8916 STATE ZIP EXPANSION: Brills Roofing 500 Grade Street Kelso, WA 98624, Tel: 206/577 -0585 STRUCTURAL FLOOR ENGINEER Andersen Bjornstad Kane Jacobs • Inc. 800 Fifth Avenue Suite 3800 Seattle, WA 98104 -3103 Tel: 206/340-2255 Fax: 206/340 -2266 SPRINKLER CONTRACTOR Crown Fire Protection (formerly Able Fire) 4932 Pioneer Pool Bothell, WA 98012, Tel: 481 - 7669 PRECONSTRUCTION MEETItt G A minimum of five. (5) days prior to starting construction, the CONTRACTOR shall contact the SHOPPING CENTER OFFICE to arrange a Preconstruction Meeting. Attendees should include at least the GENERAL CONTRACTOR, Superintendent and major Sub - contractors to be used in the construction. At the Preconstruction Meeting the GENERAL CONTRACTOR shall provide the following: • Building Permit - A copy of each of the Local and State Building permits. • Workers Compensation Certificate. • Insurance Certificate - The Certificate of Insurance should be in the minimum amount of $2,000,000 in the aggregate, $1,000,000 each occurrence and should reflect the following as 'Additional Insureds': The Richard E. Jacobs Group, Inc. Southcenter Joint Venture JG Shopping Center Mgmt. LLC • Performance, Labor and Material Bond as required. • Sub - contractors List - setting forth the name, address and telephone numbers of Tenant's General Contractor and Sub - contractors. CONSTRUCTION DEPOSIT The CONTRACTOR will be required to provide a $1,500 company check, certified check or money order payable to: Southcenter Joint Venture Please have your Federal I.D. number ready and available. The deposit or any portion thereof may be applied by the LANDLORD as a reimbursement for materials issued to or services performed directly for the CONTRACTOR, including LANDLORD's correction of punch list items not corrected by the CONTRACTOR (see below). The DEPOSITOR agrees such deposit or any portion thereof, without prejudice is any other remedy which LANDLORD may have, may be applied as a reimbursement to the LANDLORD for materials issued to and /or for services performed directly for TENANT'S CONTRACTOR (which services may include the correction of punch list items and /or for the repair/ replacement of property damaged by TENANT'S CONTRACTOR). The deposit or any then remaining balance thereof (less a 15% administration fee) will be returned to the DEPOSITOR, without interest, within thirty (30) days after the completion of TENANT'S construction obligations as required in the LEASE. ON -SITE DOCUMENTATION The CONTRACTOR will keep the following documents on -site during construction: • Working drawings. The GENERAL CONTRACTOR will build from ONE set of drawings incorporating LANDLORD'S approval comments into the BUILDING DEPARTMENT STAMPED APPROVED SET. This set of drawings will be the primary working drawings and displayed at all times during construction. • A complete set of Typical Tenant Drawings and a set of working drawings bearing LANDLORD'S stamp of approval. • A copy of the Letter of Authorization for Access (issued by mall representative at Pre - construction Meeting.) • LANDLORD'S Construction Manual issued to CONTRACTOR at the Preconstruction Meeting. TENANT'S ARCHITECT McSTICK Ou!Nfi 4t ASSoeIA FIRM - -" JOSEPH SRiNo CONTACT 50(o SECO AVENUE SUITE 3300 ADDRESS S UJASt-ilN6TON aSICf T CONSTRUCTION REQUIREMENTS RONA The following Rules govern construction on LANDLORD'S property. All references to "CONTRACTOR" shall mean the GENERAL CONTRACTOR or the TENANT if acting as its own contractor. All references to LANDLORD may equally mean the MALL REPRESENTATIVE at the shopping center, if appropriate. ASBESTOS MATERIALS In the event TENANT'S construction encounters any asbestos containing materials (ACM), TENANT shall immediately cease construction for that part of the Work which may disturb the ACM and contact LANDLORD'S Representative at the Shopping Center to resolve how to proceed. The installation of any materials that contain asbestos is strictly prohibited, EXISTING CONDITIONS It shall be TENANT'S responsibility to verify all existing construction and equipment and subject to LANDLORD'S written approval to upgrade or replace same to comply with the more stringent of: 1) governing building codes, 2) the Federal Occupational Safety and Health Act (OSHA) and regulations promulgated thereunder, 3) all laws, ordinances and regulations of applicable State, City and Local health departments and utility companies, 4) the requirements of LANDLORD'S fire and casualty insurer, or 5) the provisions of the lease. All costs shall be at TENANT'S expense. PROTECTION OF PROPERTY The CONTRACTOR shall be responsible for protecting the LANDLORD'S and any other party's property from damage. Use of fuel operated engines inside the Mall and /or space will not be permitted. FIRE EXTINGUISHERS The CONTRACTOR shall provide adequate fire extinguishers within the premises, tagged for date of inspection, while under construction. SITE ACCESS & PARKING Specific areas will be designated by the LANDLORD for parking. The CONTRACTOR shall be responsible to ensure that all construction employees working in the premises use the designated parking areas. There will be no construction trailers allowed on the property. Parking will not be permitted in any of the driveways, fire lanes and truck docks except for temporary loading and unloading, as approved by the LANDLORD. DELIVERY OF MATERIALS The CONTRACTOR shall be responsible to coordinate all material deliveries to the premises, whether for construction, fixturing or merchandising. All deliveries shall be made through the rear door of the premises either via the adjacent service corridor or truck dock area. Contact the LANDLORD prior to the delivery of materials and equipment which are too large to enter through the rear door of the Premises. Any such items are to be delivered during NON- Shopping Center hours. Where there is no rear door to access space, all deliveries, trash removal, etc., must be coordinated before or after Mail operating hours, according to LANDLORD'S direction. NO exceptions. WORK AREA & STORAGE The CONTRACTOR'S work area will be restricted to the Tenant's leased premises. Service and fire corridors and truck docks shall be kept clear of all materials, equipment, debris and trash at all times. SECURITY & AFTER HOURS WORK The CONTRACTOR must receive the prior permission of the LANDLORD for work after normal working hours. LANDLORD INSPECTIONS The Tenant's construction work will be observed periodically by the LANDLORD to verify that the work is being constructed as set forth in the Tenant's Lease, Tenant Manual, Typical Tenant Drawings, Landlord approved Tenant Drawings and LANDLORD'S Construction Manual. SAFETY The CONTRACTOR shall be responsible to ensure that all work is performed in accordance with O.S.H.A. standards. The LANDLORD may, without any liability therefore, stop work that is in violation of O.S.H.A. standards or which may, in the Landlord's opinion, cause injury or harm to persons or property. CONTRACTOR must obtain a written permit from the Mall office prior to any "hot" work lex: welding, solder- ing, torch -work, etc.). It shall be the duty and responsi- bility of the CONTRACTOR performing any cutting or TENANT'S ENGINEER FIRM CONTACT ADDRESS welding to comply with the safety provisions of the National Fire Protection Association's National Fire Codes pertaining to such work and the CONTRAC- TOR shall be responsible for all damages resulting from a failure to so comply. TEMPORARY POWER Temporary electric power will be made accessible for those Tenants where permanent power is not yet available. Where permanent power is available, it is the responsibility of the CONTRACTOR to provide the necessary equipment to supply the electrical power needed for construction. Permanent power should be ascertained as soon as possible. TEMPORARY WATER Contact the LANDLORD for coordination of temporary water service. UTILITY CHANGEOVER CONTRACTOR shall be responsible for changeover of utilities to CONTRACTOR and/or TENANT Account as soon as possible. TEMPORARY TOILET It will be the responsibility of the CONTRACTOR to provide adequate toilet facilities for all employees working within the premises. The shopping center toilet facilities will not be available for contractors use unless specifically authorized by the LANDLORD. The location fora temporary portable type toilet facility must be approved by the LANDLORD prior to its placement. TEMPORARY BARRICADE Prior to beginning any construction, the CONTRACTOR shall ensure, if required by the LANDLORD, that a temporary barricade is installed at the storefront (see Shopping Center Manager for barricade drawings and details). Where a barricade has been erected by LANDLORD using pre- formed panels, the LANDLORD shall extend the barricade past the lease line to accommodate the storefront work. The barricade shall not be extended until storefront work actually begins, shall not unreasonably obstruct mall traffic, and shall not be more than four feet (4') past the storefront lease line. All barricades shall be extended or constructed during the non - operating hours of the shopping center. No barricades shall be removed or dismantled without express written consent of the LANDLORD. Any barricade removed without prior consent will be reconstructed by the LANDLORD at the CONTRACTOR'S expense. CONSTRUCTION SIGNAGE The CONTRACTOR is not allowed to post any company name or sign on the temporary barricade. The CONTRACTOR shall post all signage as required by mall representative for public safety or general warning. BELOW GRADE CONSTRUCTION Prior to beginning any below grade construction and under slab confined spaces the Contractor must: • Prior to Locating Floor Penetrations, Tenant's Contractor must secure LANDLORD'S structural floor engineer's approval, see address this sheet • Meet hazardous confined space requirements. • Inform LANDLORD of the work to be undertaken and receive approval of same. • Submit ALL construction materials proposed for under slab installation to LANDLORD'S representative for approval. Once the approvals have been received and under slab construction commences the CONTRACTOR must photograph the installation in detail, both in progress and once completed, and submit copies of all photographs to LANDLORD. Any Below Grade construction must be inspected by LANDLORD prior to backfilling. CONCRETE Concrete most be saw -cut or core - drilled (no jack - hammering or breaking of concrete is permitted). Secure structural floor engineer's approval prior to reforming all floor work. Prior approval must be obtained from LANDLORD prior to penetrating any structural or structurally reinforced concrete. SPRAY PAINTING Spraying of finishes or paint must ohly be done if Mali HVAC and adjacent Tenant HVAC systems are either shut down or protected to avoid contamination. MALL CONTACT NAME Southcenter Mall 633 Southcenter Seattle, WA 944116-11160 Tel: 206/246 -0423 Fax: 206/2448607 INTERRUPTION OF UTILITIES The CONTRACTOR must receive the LANDLORD'S approval at least three (3) days prior to any modification to utility services that may temporarily interrupt such service to other tenants or the shopping center. NOISY CONSTRUCTION The LANDLORD has established working hours when the ccitractor may perform "noisy" construction (i.e. saw citing, core drilling, "Hilti" type fastener guns, etc.).;ontact the LANDLORD for restricted hours. LANDLORD reserves the sole right to request that CONTRCTOR reschedule any activities deemed disruptive toestricted hours. TRASH tEMOVAL & DUMPSTERS Trash Remval - All trash will be confined to the premises an removed at the end of each day by the CONTRACbR. Any trash found in the service corridors, adjacent tersnt units, and /or other public areas will be removed bythe LANDLORD and deducted from the CONTRAC deposit or billed to the TENANT. The locatiorof the CONTRACTOR'S dumpster will be determined ry the LANDLORD. LANDLORCS dumpsters and /or compactors are not to be used ty CONTRACTOR. SPRINK.ER DRAIN -DOWN The CONTFACTOR shall seek the LANDLORD'S prior approvtl at least two (2) days in advance of needing to vain the shopping center sprinkler system. No shoppinccenter sprinkler system will be left drained oversight. All systems krill be charged and operational when the CONTRACTOR leaves for the night. A $75 fee will be charged for each time the LANDLORD'S sprinkler system is drained orshut down to accommodate connection and testing requirements. ROOF &BUILDING MODIFICATIONS The CONTRACTOR will not be allowed to penetrate the roof or adjus: or modify the LANDLORD'S sprinkler system, fixtures, utilities, structure, equipment or facilities without the LANDLORD'S express written consent and will be doneey the LANDLORD'S original contractor (or LANDLORD'S designee) at the CONTRACTOR'S expense. OPERATING WHILE REMODELING In addition to any prior stated requirements, the following rules apply to stores remaining open during remodeling. PRECONSTRUCTION MEETING For stores remaining open during construction, The Store Manater must be present at the Preconstruction Meeting to dscuss plans for the remodel, time span of remodel anc related safety issues. BARRICADE . The CONTFACTOR will be required to schedule the construction n phases and provide a phasing barricade plan indicating where the barricade will be placed. SECURITY & AFTER HOURS WORK The CONTRACTOR must receive prior permission of the LANDLCRD for work after normal working hours. In addition, the Store Manager and the CONTRACTOR must prepare for and indicate whether a Security Officer or other service is needed. The LANDLORD will not bc. responsible for the security of the CONTRACTOR'S or the TENANT'S property. SAFETY TENANT COORDINATOR AMMIIMIMIRIRIMARIIRRIMMEMME In addition to the O.S.H.A. safety standards referenced previously, the Store Manager and CONTRACTOR must observe the following: • Provide a tninimum of a four foot (4') barricade around all construction areas. • Apply plastic sheeting from the barricade up to the ceiling so as to minimize dust and related damage to merchandise, customers and the public mall areas. • Verify that all workman's tools, ladders, and loose construction supplies are out of the customers, and specifically, children's reach. • Verify that any overhead dangling light fixtures, conduits, etc. are well within the confines of the barricaded and plastic sheeted areas. • Verify that the store has down -sized its stock properly so as to remain open for business and still accommodate clear fire exits through both the rear and the front of the store. • If there is any storefront remodeling required, the CONTRACTOR will be required to erect a barricade per the above details. Tel: 4401808- NAME The Richard E. Jacobs Group, Inc. 25425 Center Ridge Road Cleveland, OH 4414541ZZ Tel: 440/871 -4800 Fax: 440/808 -6909 OPENING REQUIREMENTS • Certificate of Occupancy: The CONTRACTOR shall provide the LANDLORD with a copy of the Occupancy Permit. • Certified Tenant Air Balance Report • Punch List: Upon completion of construction and PRIOR TO opening, the CONTRACTOR shall request that the LANDLORD conduct a final observation and compile a punch list. The premises will be allowed to open for business only after the LANDLORD has received a copy of the Occupancy Permit and the punch list items have been satisfactorily completed. LIEN WAIVERS & AFFIDAVITS The CONTRACTOR will be required to submit the following items at the end of the construction (forms are available from the LANDLORD): • An original notarized "General Contractor's Affidavit and Final Waiver of Lien ". • The original signed and notarized "Subcontractor's Affidavit and Waiver of Lien" for each contractor. 27 SOUTHCENTER TYPICAL TENANT GUIDELINES TTG -Q 1 TALL'S CAMERA DBA THIS SHEET MUST BE INCLUDED AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, LOCAL AUTHORITIES HAVING JURISDICTION AND BIDDING CONTRACTORS The Richard E. Jacobs Grtiur NOVEMBER 1999 SEATTLE, WASHINGTON F664 UNIT NUMBER REVISIONS DATE: JOB NUMBER: DATE' DRAWING NUMBER: TT -01 6 4111111 MIC 0 1111" GODIVA AROMATHERAPY _ _ _ 145.17 P _1;11 0 0 4" d 2 , 14 L" FLORSHEIM • GARDEN BOTANIKA PAPYRUS , MEISRELD JEWELERS KENNETH BEHM GALLERY I I • SHOES • PA • • RAINFOREST CAFE i NORDSTROM THREE LEVELS PROSSER PIANO 9237 BIAGIO 78.3 TALL'S CAMERA 97.7 MADE IN WASHINGTON SPENCER GIFTS 78.3 24, 249.4 2599, P. ABERCROMBIE 30 110 70 NX SHOP, a pl roe. 57 Rol AS 0 KER 0 r; '4 3 ul 54.1771 E195.50 A7 230,7r 2425.0 60 675.0 EI I SWEET FACTOR Y SUNG D SILVER & GOLD SNIPS Be TR. 621 CHARACTER CORNER 76 1 I IVI KS STICKS WA CIH WORLD URNEY;; 8041 KAY TOYS 97.87 SLY. COIN 97.67 SOFTWARE ETC. 3.42 67.67 RABIC SHACK 6567 23.17 26.39 5. 2 SCRENNel STORAGE MAINI0NANCE 101.14 LO o '; ENTRA E HIGH Se MICH, ZUMIE7 87.. I083.90 1095.0d RECEIVING SEARS THREE LEVELS YFOTAL FLOOR AREA = 170.9000 249. J LTgEl'nfLr STATISTICS . PUB. ca6N,_ 4.1 GOD! VA 11 41.17 02 THE BON MARCHE FOUR LEVELS YrOTAL FLOOR AREA - 250.40. ENTRANCE FaFF cs PUSUC CORRIDOR 55.50 WANDA, THIS PROJECT - SPACE NO. F664 M HAIR SOUTHCENIER MASTERS COBBLER ENT ENTRANCE F:6,6,,T° A FROM URI/5 E594 (WAS - NACHO FAST,. E586 cll. EXPRESSLY PORTRAITS & FC44 (WAS MANCHU WOK .2 raIVAMiatt 69 5d STORAGE 11. 7 BUILDING IN NE G.LA. KIOSK G.L.A. L_ COE G.L..A. RAGE G.L.A. EMENT G.L.A. TO ENCLOSED MALL C MA R IN R TE ID N ' ANCE 2275.07 24.50 L 1+2+31-4-F5=6 MEZZANINE NON-LEASABLE UNBUILT KIOSK G.L.A. UNBUILT POPOUT G.L.A. DEPT STORE ENCL MALL rsm6d. 95.50 U rgL 3EFVCIENCY RATIO 6/12=13 A 26.565.58 243.70 26,809 28 9 9,4.45 492.. 783.00 .2 1 l 208.0 3 U:260,2400 7.75,2400 9.25.4.00 8.25.4.00 FOR REFERENCE ONLY 6/8/01 31 564.71 8 492.20 1 22 88 197M M.25 M663.51 M877.33 37,47239 42,42.04 NOTE: LOCA ON OF TUNN 706.85 566.97 8.67x24.00 1.50.4.00 0.50.4.00 7.75824.00 1.00.4.00 3.00224.00 S AND MAN, 39.98 MERVYN'S TWO LEVELS •TOTAL FLOOR AREA = 6523. JCPENNEY THREE LEVELS 'TOTAL FLOOR AREA = 240,597st 150 20' 1 4- 1'1 BUILDING STATISTICS C D "' 2 7 8 7 5. 8 0 ' 0 ' 69.60 7 716.71 63 742. 73 281 11 18.368.31 9,308.43 2 ,530.59 2.310.83 1,668.47 3.080.82 22,762.31 19,230.67 86,504.75 92,511.78 LEGEND IND -INFORMATION BOOTP ■';N 1:2,-A 444 PL L O ° 0177ARRAT T ARTP ' E r R DIR -I4ALL DIRECTORY SPR -SPRINKLER RN PROJEC L.. l )LN E U U N ' O ' nElr.tl i"S' A R L01% -LOCHTS AAA.. -WALL BRACING RHIS STOIPPYRONT. JCL -,IATPPOR CLOSET O OLES SHOYIN 240. 4,295.00 E F 57.961.54 201.00 490.05 58 652.59 30,454.38 5 060 30 3,526.01 39,040.69 97,693.28 226.55 45,900.90 351.70 748.39 94 14 47 195.13 17,933.56 2,5..71 3,029.13 23,509.40 70.704.53 G TOTAL .32 322400 1 7 3 8.470.50 4 32,469.61 7,535.47 660.85 309.37 8,505.69 40.975.30 333, 102, .80 17,538.92 8 2,310.83 9 12.6 /3.05 10 134,589.60 11 468,304.47 12 71.26% 13 R V ON PLAN SH NW BE FIEW VERIFIED 1,773.00 3,271.00 14 Tal" 1 = 7 1 2 1 ° 1. ' 9 ° 8 1 1: 5,795.3a 17 JP 1 -40 9.,,a2u ay, JOS 62 LP 1 5CLR1 SCLI7MCCNITIO MALL 03-.31-87 ATE: !2/07/00 N IND () Job Title Tails Camera Southcenter Space F -664 Tukwila, Washington FT III /1 III III /`\ I II 4L.—' J L A 0 xrnA 1 � sX r Sheet Content DEMOLITION FLAN Revision PERMIT SET - 6/20101 to I o I M D to Z 10 m 0 m z R 3745 AR Drawn By REGISTERED ARCHITECT SEF1 x. SHING ST, OF WASHINGTON Job Number JS Checked By 6 -20 -01 Date 3300 Smith Tower Seattle, Washington 98104 206 622 -4981 Fax: 206 682 -4289 MESHER SHING& ASSOCIATES ARCHITECTURE SPACEnPLANNING AND a COMMERCIAL INTERIOR 0 DESIGN DOOR SCHEDULE DOOR NO. awi DESCRIPTION DOOR FRAME HARDWARE GROUP RATING REMARKS SPECIAL REMARKS MAT. N. MAT. FIN. I A 18'- 0'X8' -6' ALUM FE MTL PAINT - - 2 B 3' -0'X7' -0'X1 3/4' S.C. WD PAINT MTL PAINT - 20 MIN. SEE DETAIL 5/A2,2 3 _XIST 3'- 0'X7' -0'X1 3/4' H.M. PAINT MTL PAINT - - 4 EXIST 3'- 0'X7' - 0'X1 3/4' H.M. PAINT MTL PAINT - 20 MIN. Cnp,ight Mesber Sbing and Associates. All rights reserved. Not to be repr oduced without permission. Original sheet site 24 DOOR TYPES 5/8" OKE TYPE 11 X 1 ' EA. SIDE \ 7 -1 TYPE 'A' (2) 3 5/8" MTL. STUDS H/ STIFFENER H.M. DOOR FRAME (5) MTL. DOOR JAMS ANCHORS AT EACH DOOR AS JAME AND (I) FLOOR SCHEDULED .�- CLIP ®DOOR JAMB DETAIL SCALE: 3' - 1' -0' (HEAD SIMILAR) OVERHEAD ROLLING DOOR OVERHEAD ROLLINS DOOR: MFR: DYNAFLAIR CORP. TYPE: DYNAPLEX W/ PLEXI -0LA$S OPERATION: MANUAL CORRIDOR SOLID GORE TYPE 'B' WOOD DOOR 12'5 5/8" 24' -0' VERIFY VERIFY EXISTING ELEC. PANEL O STORE ROOM 9' -10 1/4" VERIFY FLOOR PLAN ` .1 1 ..) SCALE: I/4' = 4'2" ALIGN FILM PROCESSING WALL TYPES CASHIER 4 -0" 17 LINE OF METAL DECK CONT. RUNNER • I-HR RATED WALL 3 5/8' X 20 N. DIAL. KICKERS ANCHOR TO STRICT. m 24" O.G. CEILING LINE 3 5/8° X 20 SA. MTL. STUDS • 16 O.G. W/ 5/8" OWES TYPE 'X' ON EACH SIDE SASE PER SCHEDULE STRICT. SLAB SLATWALL DISPLAY S SASE CABINETS DISPLAY GASES 9'-O' 66' - 5 5/8° VERIFY t 50' VERIFY NOTE: ALL GASEWORKS ARE P O. 4' -0" EXIST. I-HR. RATED VERIFY DEMISING MALL SERVICE AREA SALES AREA ° 24'-0" A5.I 4' -0" Q CASHIER 2' -0" 2' -2 WIRELESS DISPLAY t BASE CABINETS I/2 10'-6" VERIFY 4' -0" 4'-O" • VERIFY 2' -0' t 5' -I 5/8" TYP. I- A EA. END 5'" I GENERAL FLOOR PLAN NOTES I. THE GENERAL CONTRACTOR AND CASEWORK CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 2. THE CONTRACTOR SHALL REPAIR EXISTING FLOOR, CEILING AND MALLS DAMAGED DURING CONSTRUCTION TO MATCH EXISTING. 5. THE CONTRACTOR SHALL PROVIDE NON- COMEUSTISILE BLOCKING AS REQUIRED, AT CASEWORK AND EQUIPMENT LOCATIONS. REFER TO PLANS, ELEVATIONS, DETAIL DRAWINGS, NOTES AND MAMJFAGTURERS SPECIFICATIONS. LEGEN D: EXIST. MALL TO REMAIN NEW MALL O O p 9 X <A> LEV"I'ER INDICATES WALL TYPE El \--- EXISTING COLUMN EXISTING MALL NEUTRAL STRIP 3 "x3 "x3/16" TUBE STEEL LEASE LINE LINE OF OVERHEAD ROLLINS DOOR DISPLAY WINDOW 3 "x5 "x3 /I6" TUBE STEEL `— EXISTING COLUMN EXISTING MALL NEUTRAL STRIP Sheet No. Tukwila, Washington Space F-664 Southcenter FINISH SCHEDULE PAINT PT -I PARKER *5415A, TRAIN SMOKE CEILING PT -2 PARKER *4O95N, PLUM WINE WALL ABOVE CASEWORK SIENBAND PT -3 PANTONE 1655 SIENA6E "CAMERA° PL. LAM PL -I NEVAMAR *TM -2 -IT, OCHRE TEMPERA GENERAL CASEWORK PL -2 NEVAMAR *5- 2 -62T, ARUBA CLAY CELLULAR SOFFIT, FILLER PANELS PL-4 WILSONART *1241 -60, SLATE GREY STOREFRONT PL-5 FORMICA #'465 -56, ROYAL LAVENDER CELLULAR CASEWORK CARPET CPT-1 MASLAND CONTRACT, SILHOUETTE 1200 SALE FLOOR, FIELD COLOR: 02021 INK, 100% MONSANTO ULTRON,VIP NYLON 6,6 CPT -2 MASLAND CONTRACT, SILHOUETTE 1200 SALES FLOOR, FIELD COLOR: 02023 CABERNET, 100% MONSANTO ULTRON,VIP NYLON 6,6 CPT -5 SHAW -REGAL COLLECTION *P1601, LACQUER SALES FLOOR, ACCENT STONE ST -I OREGON TILE 4 MARBLE GRANITE TILE MALL ENTRANCE, DISPLAY WINDOW BASE COLOR: 6T /OTM /111014 FINISH: HONED SIZE: 125x12" MIL -I FORMICA DECOMETAL, 4255 MIRO PERF STOREFRONT FASCIA LINOLEUM LIN -I FORGO, MARMOLEUM SHEET LINOLEUM FILM PROCESSING AREA *304? NEUTRAL GRAY i Gapteighl Masher Shing and Associates. All rights reserves. Not to be reproduced eithoct permission. Original sheet size 26 "x36 CARPET ADD /LEVEL CONC. SLAB AS NEEDED O TRANSITION DETAIL FINISH PLAN U SCALE: 1/4' = r -m' METAL TERRAZZO STRIP - INSTALL FLUSH, SMOOTH $ LEVEL TILE TO MATCH EXIST. MALL TILE GENERAL FINISH NOTES I. ALL NEW AND EXISTING SURFACES INCLUDING FLOOR, SUB- FLOOR, WALLS, CEILINGS, ETC., SHALL BE PREPARED AS REQUIRED FOR APPLICATION OF NEW MATERIALS AND FINID CO. 2. PROVIDE SMOOTH TRANSITION STRIP AT JOINTS TO EXISTING FLOORING. 10 LEASE LINE MALL TILE: EXTEND MALL BORDER TILE 5' -0" FROM LEASE LINE INTO TENANTS STOREFRONT AS SHOWN - ALIGN NEW TILE MI EXIST. &ROUT LINES. G.C. TO OBTAIN MALL TILE FROM MALL MANAGEMENT • TENANTS 6.O.S EXPENSE. a) E CO Sheet No. W 0 WZ IDz 0< WJ = W UU W0_ <u) J U W 0 J 0 Z A2.3 0 S z (n W 0 LU 0 LU W H Z MAIN RUNNER GENERAL CEILING NOTES I. COORDINATE CEILING GRID WITH HVAC DIFFUSER-S. LIGHT FIXTURES, FIRE ALARM SYSTEM AND SPEAKERS. 2. EXIT 516N5 AND ILLUMINATION SHALL BE IN ACCORDANCE WITH LOCAL BUILDING CODE. 5. CONVENIENCE OUTLETS AT HS" AFF UNLESS OTHERWISE NOTED. 4. EXTERIOR 5ICNACE ! LISHTIN6 TO BE CONTROLLED BY A 24HR. TIME GLOGK AT ELECTRICAL PANEL. TINE CLOCK TO BE SET ACGORDIN6 TO OWNERS SPECIFICATIONS. LIGHTING LEGEND ITEM DESCRIPTION A LIGHT TRACK, JNO, T1J- 45,12 BL, BLACK TWO CIRCUIT TRACT B LAMP, JUNO, T4ON689 NOW PAR TO BLACK IE NOW X IS = P00 PORCELAIN SOCKET, BLACK G RECESSED DOWNLIEHT S8 AT PERIMETER CASEWORK (PROVIDED BY CASEWORK CONTRACTOR) D RECESSED DOWNLIGHT LISHTOLIER, b" CLEAR, HORIZONTAL LAMP NV COMPACT FLUORESCENT E 2 x2 , 2 -T1)15E FLUOR. FIXTURE F 4' I -TUBE FLUOR FIXTURE 6 2' WIDE STANDARD LAMP STRIP FIXTURE (S DISPLAY GASES) (PROVIDED BY CASEWORK CONTRACTOR) H FLUORESCENT LIGHT FIXTURE EXISTING TO REMAIN LIGHTING CALCULATIONS CEILING CLIP FASTEN TO STRUCTURE AS REQUIRED I /2" EMT COMPRESSION STRUT OVER 8ga HANGER WIRE *6 SELF TAPPING SM SCREW TO GLIPSTRUT TO BE TIGHT TO STRUCTURE S /4" EMT NOTONED OVER MAIN RUNNER DRILLED 5/52" HOLE M -I/8" BOLT ! LOGKNUT, SET AFTER LEVELING GEILINS *5 XI /2" SELF TAPPING DRIVE SCREW 4-86A. HANGER MIRES SPLATE"D O 45 DEG. TYP S EA. STRUT NOTE: I. MAX SPAGINS GF STRUT 12'X12' 6 o' MAX S WALLS 2. INSTALL PPR UBC STD. 4T -18 QUANTITY WATTS WATTS 5 1 81+1 X 5 = 90 9 5 191/4 X2 X5 = 110 52W X 19 = 608 5 521N X3 = 96 TOTAL TOTAL WATTS ALLOWED: AREA = 1510 5.F. x 15 WATTS = 1965 WATTS TOTAL WATTS USED: 1864 WATTS TOTAL WATTS USED < TOTAL WATTS ALLOWED CROSS TEE = 1564 r � SEISMIC ERAC!.NG DETAIL No Scale 10 V4' = I' -0' kOVI• VENTS EQUIPMENT RED E�Ji :--I EXISTING ACT CEILING AND LIGHT FIXTURE TO REMAIN j 00 G t o ¢G G 0 4 ®REFLECTED CEILING PLAN at bGALE: ® - G I -06 l 0, G ; �f * *0 *G U0 -G 1 *0 12" H1611 CASEWORK SISNBAND S + -0" PL. LAM. ON (2) 5/4" PLYWOOD S +8'-0" PARABOLIC, E6£GRATE LOUVER PANEL W/ SPECULAR SILVER FINISH 11/2" x I IT CELL SIZE ON 'ARMSTRONG' PRELUDE 15/16" SRID W/ SPECULAR SILVER FINISH -- -- PL. LAM ON 3/4" PLYWD. ON 5 5/5" M I . STUDS S +8' -0" LOW CEILING ®REFLECTED CEILING PLAN at HIGH CEILING SCALE: I/4' = I' -0' I I I C-0- 12" HIGH CASEWORK SISNBAND O +T-O" 2'x2' ACT CEILING TILE WITH TESULAR EDGE/REVEAL O +11' -0" LOCATE SKID AT CENTER OF SPACE DIAGONALLY AS SHOWN ¢0 1 II 0 G- G 12'-0" <>G PARABOLIC. ESGGRATE LOUVER PANEL W/ SPECULAR SILVER FINISH 11/2" x 11/2" CELL SIZE ON 'ARMSTRONG' PRELUDE I 15/16" GRID W/ SPECULAR SILVER FINISH � 4 6 " —'I PROVIDE DEEP CELL PARABOLIC LENSES ON ALL 2'x2' FLUORESCENT LIGHT FIXTURE 4" " 4" I— ALIGN SOFFIT S CORNER D O FACE OF NEW STOREFRONT FASCIA NEW OVERHEAD ROLLING POOR 6WB SOFFIT S +8'-6" A4.1 OPENING AT SOFFIT (VERIFY CLEARANCE) O FACE OF EXIST. MALL FASCIA FACE OF EXIST. MALL BULKHEAD OUTLINE OF O.H. ROLLINS DOOR OUTLINE OF O.H. POOR HOUSING O Sheet No. A2.4 Pap lent Mesher Shine and OVERHEAD ROLLING DOOR DISPLAY WINDOW W/ BUTT JT. GLASS GRANITE TILE BASE 5T -I FLOOR LINE —\ STORE ROOM EXISTING ACT CEILING TO REMAIN EXISTING PARTITION TO REMAIN STORE ROOM right, reserved. Not to De reproduced without perrnisslon. Orlginel sheet size 24' OUTLINE OF LIGHT FIXTURE PAINT EXISTING ACT CEILING TO REMAIN EXISTING PARTITION TO REMAIN PAINT GLOSS WHITE AT AREAS ABOVE PARABOLIC LOUVER PANELS OUTLINE OF LIGHT FIXTURE \ \ -- FASCIA E I 1 PL -2 1 SLATWALL DISPLAY, F.O.I.G. 1 PL -I 1 FASCIA SA ND 1 PL -2 SIONBAND, F.O.I.C. 1 PL-I1 PAINT 1 PT -2 1 AREAS ABOVE PARABOLIC LOUVER PANELS OUTLINE OF LIGHT FIXTURE, TYP. III COUNTER M/ GLASS DIVIDER, F.0.1.0. —\ FILM PROCESSING I PT -2 1 FASCIA STORAGE, F.O I.G. 1 PL -I 1 PL -2 1 2'x4 METAL GRID WITH PARABOLIC LOUVER PANELS SALES AREA SERVICE SIGNBAND FASCIA I PL -21 SLATWALL DISPLAY, F.O.I.0. STORAGE, F.O.I.C. PL 1 I BALES AREA 1 PL 1 1 P L -I 1 PAINT /GLOSS WHITE AT CI — — = - - - -s— - -17 © INTERIOR ELEVATION SCALE: 1/4' = ® INTERIOR ELEVATION SCALE: 1/4' = 1' -0' NEW ACT CEILING FASCIA BAND LPL -21 1 PL - ! 1 r DISPLAY GASES, F.O.I.C. 4 FRONT COUNTER, F.O.I.G. INTERIOR ELEVATION EXISTING ACT CEILING TO REMAIN EXISTING PARTITION TO REMAIN FILM PROCESSING 1 STORE ROOM EXIST. MALL BULKHEAD EXIST. MIRROR TO REMAIN OUTLINE OF 515NAGE NEW METAL FASCIA 1 - - !1 OVERHEAD ROLLING DOOR FLOOR LINE EXIST. MALL FASCIA EXIST. MIRROR TO REMAIN OUTLINE OF 516NA6E NEW METAL FASCIA 1 MT-I 1 OVERHEAD ROLLING DOOR FLOOR LINE Gl'8 SOFFIT 25(4' METAL GRID WITH PARABOLIC LOUVER PANELS FRONT COUNTER, F.O.I.C. rcm INTERIOR ELEVATION SCALE: 1/4' = l' -0' rD0 ig6 GLASS DIVIDER, F.O.I.C. SLATWALL DISPLAY, F.O.I.C. t9� ® INTERIOR ELEVATION SCALE: 1/4' = I' -0' 4. -8' 11 !1MP 4° -- WALL DISPLAY BEYOND DISPLAY WINDOW = WITH BUTT JOINT Q = 6LAS5 n GRANITE TILE BASE 1 ST - I 1 18' -0 DOOR OPN6. 20' -0" LEASE LINE OUTLINE OF LIGHT FIXTURE S16NA6E BY 516NAGE CONTRACTOR n II R h! ,dGili�i�l l l. FASCIA BAND 4` BEYOND FRONT COUNTER, F.0.1 C. n STOREFRONT ELEVATION LIGHT FIXTURE, TYP. VERIFY LOCATION SLATWALL DISPLAY, F.O.I.C. FASCIA LIGHT FIXTURE, TYP. VERIFY LOCATION SLATWALL DISPLAY, F.O.I.C. 1PL 1 PL -2 I 1 PL - ! 1 EXISTING MALL FASCIA EXISTING MIRROR BAND TO REMAIN - REPAIR OR REPLACE IF DAMAGED NEW METAL FASCIA GRANITE TILE ON 5/8" 6143 ON METAL STUDS 1Kr-!1 I/2' BLACK METAL REVEAL ALL AROUND BETWEEN MALL PIER/BULKHEAD AND NEW TENANT STOREFRONT EXISTING MALL NEUTRAL STRIP, TYP. BOTH SIDES 1 MT -2 1 1 ST -1 E V V/ Sheet N. A3.1 0 BOTTOM OF EX15T.JOIST *12 WIRE 4' -0" O.G., TYP. ALMOND MELAMINE a INTERIOR NOTE: ANY ATTACHMENT TO STRUCTURE ABOVE. MUST BE BY CLAMPING, WIRfNG OR WELDING TO TOP OR BOTTOM CHORD OF BAR JOIST, OR TO ANGLE IRON • SPANNED THERE BETWEEN, SEE DETAIL BELOW FOR ANY ATTA.CR IPNT TO A POINT GREATER THAN 6' FROM A PANEL POINT. NO OTHER METHOD OF ATTACHMENT SHALL BE PERMITTED W /OUT PRIOR WRITTEN APPROVAL FROM L.L'S T.C. iF 'VARIES' DIMENSION LS MORE THAN (61 SIX INCHES PROVIDE NEW DIAGONAL FIELDWELDED TO JOIST. RUN FROM CONCENTRATED LOAD POINT TG NEAREST • TOP OR BOTTOM CHORD PANEL POINT. TYP. CONCENTRATED LOAD 5 JOIST REINFORCEMENT DETAIL NO SCALE ti art Permission_ Original sheet size 24' r 36' 3/16" BENT PLATE BETWEEN JOISTS, TYP. SEE DETAIL '7/A4.1 �EL. 11' -O" A.F.F. ACT CEILING 2'x2' ACT CEILING FASCIA : PL. LAM. ON 3/4" PLYWD. ON 3 5/8 "X20 GA MTL. STUDS IPL -2I 1 SECTION at SOFFIT V EL. 8' -0" A.F.F. PARABOLIC EGGGRATE LOUVER PANEL W/ SPEGULAR SILVER FIN., I I/2" x 11/2" CELL SIZE, ON 'ARMSTRONG' FsRELUPE 15/16" GRID W/ SPEGULAR SILVER FINISH UNISTRUT, CONT., BETWEEN JOISTS FOR ROD FASCIA IPL -2I PARABOLIC LOUVER PANELS OUTLINE OF ENDPLATE ABOVE EXL T. WALL I/2" BLACK MTL. REVEAL / ALIGN NEW WALL W/ EXIST. GRANITE TILE ON 5/& GWB ON MTL. STUDS 3 "X3" T.5. COLUMN FOR DOOR SUPPORT ALUM. DOOR GUIDE OVERHEAD ROLLING DOOR LINE OF OPENING ABOVE O TYP. DOOR SUPPORT DETAIL SCALE: 1 1/2' I' -O' 11 CONNECTION DETAIL SCALE: 3' PROVIDE 5/8" FIRE RATED DRYWALL CLOSURE TO DECK ABOVE IF NOT EXIST. 3/16" BENT PLATE BETWEEN JOISTS, TYP. 15 GA. L CONTINUOUS 5/8" TYPE 'X' GWB SOFFIT 6 "XIS GA a124" O.G. W/ 6" TRACK SECTION at SOFFIT BOTTOM OF EXIST. JOIST -- 3/16" BENT PLATE BETWEEN JOISTS METAL BRACE 00 ° eo go —I--1/2" DIA. 3 5/8 "X18 GA ALL THREAD MTL. STUDS I HANGER ROD G 24" O.G. i MN ii vo ......0� I .l 1no���momono iiiiii 7 ai - *12 WIRE ® 4 O.G., TYP. ALMOND MELAMINE ® INTERIOR 15 SA. L CONT. 5 /3" TYPE 'X` GWB SOFFIT BOTTOM OF EXIST. JOIST 3/16" BENT PLATE 3 "X5" T.S. COLUMN FOR DOOR SUPPORT EXIST. MALL BULKHEAD BOTTOM OF EXIST. JOIST EXIST. MALL BULKHEAD 3 "X3" T.5. COLUMN BEYON:) FOR DOOR SUPPORT IP EXTEND NEW STUDS TO OVERLAP EXIST. ,• EXIST. MIRROR BAND p I I 1 bl I ( i i I 10 "X15 GA MTL. STUDS ® 24" O.G. H/10" TRACK CONNECTION DETAIL \-7— SCALE: 3' = 1' -0' O CONNECTION DETAIL SCALE: 3' = 1' -0' EL. 14'-0" A.F.F EXIST. MIRROR BAND HEIGHT I 5T -I I MT - 1 EL. 12' -0" A.F.F� STOREFRONT HEIGHT SCREWS AS REGD., TYP. 6 "XIS GA MTL. STUDS ® 24" O.G. OUTLINE OF SIONAGE NEW GRANITE TILE - METAL FASCIA EL. 8' -6" A.F.F GWB SOFFIT BOTTOM OF EXIST. JOIST 3/16" BENT PLATE BETWEEN JOISTS METAL STUD BRACE BACK TO BACK 3 5/8 "XI5 GA MTL. STUDS ® 24" O.G. #12 WIRE 4' -0" O.G. ® _I EL1' -0" A.P.F. ACT CEILING 2'x2' ACT CEILING SHADOW MOULDING ® EL. 8' -6" A.F.F. GWB SOFFIT — Le 3/16" BENT PLATE BETWEEN JOISTS, TYP. IS A. L CONT. 5/8" TYPE 'X' 6W13 SOFFIT 6 "Xl& GA MIL. STUDS ® 24" O.C. W/ 6" TRACK 1/2" REVEAL —� PLASTIC LAMINATE (EXPOSED SURFACES) ON (2) 3/4" PLYWOOD I P1=21 EL. 8' -O" A.F.F. —1/2" DIA. ALL THREAD ® DETAIL at SOFFIT SCALE: 3' = 1' -0' PROVIDE 5/8" FIRE RATED DRYWALL CLOSURE TO DECK ABOVE IF NOT EXIST. — EXTEND NEW STUDS EXIST. MIRRO TO OVERLAP EXIST. BAND HEIGHT EXIST. MIRROR BAND EL. 12-0" A.F.F. STOREFRONT � HEIGHT 15 GA. L CONT. 10 "XIS GA MTL. STUDS 24" O.G W/10" TRACK — 5/8" TYPE 'X' GWB SOFFIT UNISTRUT, CONT., BETWEEN JOISTS BOTTOM OF EXIST. JOIST HANGER ROD PARABOLIC LENS SHADOW MOULDING ACT CEILING METAL TRIM, CONT. L I 1/2 "XI I /2 "X3 /I6 "X3" I/2" DIA. ALL THREAD HANGER ROD L.1 I/2 "XI I/2 "X3/16 "X3" BOTTOM OF EXIST. JOIST EXIST. MALL BULKHEAD 3 "X3" T.5. COLUMN BEYOND FOR DOOR SUPPORT n SECTION at SOFFIT EL. 14' -0" A.F.F. SCREWS AS REGD., TYP. 6 "XIS GA MTL. STUDS ® 24" O.G. OUTLINE OF SIGNA6E NEW GRANITE TILE 1 ST I NEW METAL FASCIA IMT -I EL. 8' -6" A.F.F. 6113 SOFFIT PHASE I BUILDING 'D2' PHASE II FOOD COURT -.- TSG -A1 TSC -Ct r TSG -DI TSG -03 TSG -172 NORDSTROM MERVYN'S MERVYN'S I 1 NORROM MERVYN'S waaoSTROM MERVYN'S NOOM SEARS ',6:, TFE � , .• / /,,I ol. Sow / // i % o / /// �/ / % � ' .nu kitmoLIIII - -./ %� / % �I� �� , � % % os..o 0 0 // / y s, 1creNlEV / iiij• % � ! r " ; wi ll 111111111111 =' ; i$, 11 '�i TH BON !$ .. n �i" � h _. ■ sASA 1111111 T11E BOw i ''P � /% / ��_ �� ® � � 1�' r `i I ■ f� � _,�_ _ _ _ - o avwaoo _ . __ ELECTRICAL DESIGN �- �ooso ,� ■i PI 'S �� s ® II ❑ i1 / ! ,1 ❑ _ ( -111 I m .. ! 111. . 1 1 _ � �'� s .. uu I' D MI uioiii. /� , 111111111111 1cPe1.EV ■� '� o .. B� ... w.. o 1 ❑�_ ! :11 11hr� ■ _ IM • of I. m :_: ���. ■ I � i��:ti ' . I� = ` on 1 III \1� - 11111 1cPOV i� >�� -. :1� initial{ G _ Eli • al. : :I� tom 47 :- - 0 ! i „e / 1 wl.a . S EARS KEY + LinE1._.� SEARS Ei /c' �� '� SEARS TIMIS1 I I TSG -172 KEY PLAN PLAN CRITERIA, DETAILS TSG -E2 AND RISER DIAGRAMS KEY PLAN /� Sheet 1 or 2 TSG - F3 TSG - f1 TSG -173 TSC- -E1 TSC -172 TSG -D2 KEY PLAN NO SCALE , ■ ,. , NC SCALE , NO SCALE , I D SCALE al ALL INSTALLED EQUIPMENT, ACCESSORIES. AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. ALL INSTALLED EQUIPMENT. ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. ML INSTALLED EQUIPMENT, ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM ALL INSTALLED EQUIPMENT. ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. AS REQUIRED. UNIT NUMBER METERING F SWITCHBOARD CONDUIT AND WIRE TENANT'S PHASE II NOTES: PHASE I NOTES: FJFCTRICAI NOTES: DBA TENANT SHALL PROVDE A SMOKE DETEDTOR RJ THE RETURN SHUT DOWFi THE HVAC UNIT UPON DETEC ?ION OF SMOKE. A U UGITT SHALL BE INSTALLED IN THE STOCK AREA AS A PART 2. UPON DETECT. OF RITE, GAS AND ELECTRIC POWER IS TO BE SHUT OFF FOR COOKING EQUIPMENT UNDER THE HOOD. 3. THE LANDLORD HAS PROVIDED A 120 V CIRCUIT FOR THE TENANTS WILL BE MADE AT A JUNCTION 80X LOCATED BY THE LANDLORD UNIT. COORDINATE CONNECTION WITH THE LANDLORD. 4. TIME SWITCH SHALL CONTROL MENUBOARD, UNDER COUNTER LIGHTING AREA LIGHTING. USE PARAGON TYPE 70007 -0 OR EQUAL 24 5. WNTER LIGHTING SHALL BE 10 MILLIMETER NEON LIGHTING MATH 00TH 6 60 MILLIAMP TRANSFORMER. 6. THE FOOD COURT FLOOR IS A STRUCTURAL SLAB. TENANT MUST APPROVAL OF THE LANDLORD FOR ANY UNDER FLOOR CONSTRUCTION, CONSTRUCTION BEGINS. CONDUIT AND WIRE ATP. DUCT THAT WILL TEST -ALARM SWITCH OF THE SYSTEM. AUTOMATICALLY SIGN. CONNECTION WITHIN THE TENANT St SERVING HOUR 7 DAY TYPE. (WHCTE) HAVE WRITTEN BEFORE TENANT'S 1. TENANT SHALL PROVIDE A SMOKE DETECTOR IN THE RETURN SHUT DOWN THE HVAC UNIT UPON DETECTION OF SMOKE. A k LIGHT SHALL BE INSTALLED IN THE STOCK AREA AS A PART CONDUIT AND WIRE AIR DUCT THAT WILL TEST -ALARM SWITCH OF THE SYSTEM. TENANTS 1. TENANT SHALL PROVDE A SMOKE DETECTOR IN THE RETURN AIR SHUT DOWN THE HVAC UNIT UPON DETECTION OF SMOKE. A & LIGHT SHALL BE INSTALLED IN THE STOCK AREA A` A PART CONDUIT AND WIRE DUCT THAT WILL TEST -ALARM SWITCH OF THE SYSTEM. TENANT'S UNIT I-4 T - - - 1 I - I -- - - 1 I I I I ®1 1 1 i D FUSIBLE SWITCH I r -- r - 1 M I r---�---rr METER AND SOCKET --A r ® -- - I M t 1 I r r--- i ®1 GRADE FINISHED FLOOR r--- r- i 1 / I 1 I I r _I___1 OR 1 _ I - -- ry CIRCUIT BREAKER D i I ® p 1 I - -- + - -- - - -r1 I I M I I I DI 1 pi 1 r +--- r -- -ri 1 1 pi iOI p1 1 - -rti- r -- - ri I i i 1 i I I 11 1 1 I 1 1 ___ 1J___J___J-L, UNIT UNIT METERING r T - - - 1 SWITCHBOARD OR METERING I T - - - 1 SWITCHBOARD I 1 1 I I 1 rr -- - - -- - i ' r r M 1 t I M l 1 1 1 pl _ _ I 1 I I _rl I Oj Di iO l 1 1 UNIT lOt _ - r--- r - - -rT r r I 1 1 1 1 I METER AND SOCKET -•F M I I I M 1 1 1 I 1 D 1 p1 1 r ___ r ___ ri I M I i M i i 1 p . 1 DI I r-- - r--- rT--- r---rt I 1 1 1 I i Mi i MI p DI F--- r--- r +--- r -- r+ I I 1 1 1 GRADE/FINISHED NISHED FLOOR I I I I 1 I I I I 1 �1_- _1J__- J___1_ n FUSIBLE SWITCH CIRCUIT BREAKER - r - - - t - r r. I I 1 1 METER AND SOCKET -+ M 1 M 1 1 OI p l 101 _ DI r___rr r _. ® i Di i ` � i DI I r--- r- r + --- r - - - r+ O I I I I I D ■ O D M i ii Mi iI r--- r-- ---- r - - - r + r+ 1 1 GRADE/FINISHED FLOOR I I 1 I i _ - -_ i 1 i �__1___J_L. FUSIBLE SWITCH OR CIRCUIT BREAKER PARTIAL RISER DIAGRAM METERING 7 - - 1 THIS SHEET & TTG -01 MUST BE INCLUDED AS FUSIBLE SWITCH OR & LEGEND: 120/205V 30 4W- 5. THE INTERRUPTING OVERCURRENT AMPERES 6. TENANT /SWITCHBOARD WITHIN BREAKER, ETC.) THE DUCT SMOKE DETECTOR SUPPLY AIR DUCT S MOKE DETECTOR RET DUCUR AIR DUCT CAPACITY OF T METERING SWITCHBOARD DEVICES SHALL BE A MINIMUM OF 65,000 RMS AT 240V AC. TO PROVIDE A MAIN DISCONNECTING MEANS TENANT'S UNIT. SWITCHBOARD I I r -- -r rT ---r rl 1 M I M i 1 1 i i I r- - ---- T--- ---1 METER AN SOCKET --f ® p 1 ®i D 1 i i r--- r--- rr --- r - - -r1 _ 101 1 i ®I i I 1 I I]I I D I I I 1 1 I Iyl /I I ® I 1 r- r +--- r - - -rt i \ -J - I - O I 1 1 D i GRADE /FINISHED FLOOR 1 I I I i 1 1 I I I 11 I 1 1 I I 1 1 r J___1___J.. J ___ 1_t_ CIRCUIT BRFAXER PART OF TENANTS SUBMITTAL TO THE LANDLORD, BIDDING - CONTRACTORS AND 1. 2. 3. 4. 120 BY TENANT B1' LANDLORD METER BY UTILITY AT TENANT'S E %PENSF. ALL EQUIPMENT ADDITIONS TO THE NcTERING (SOCKET, METER, FUSIBLE WITCH, i:IRCUIT SWITCH COMPATIBLE UFACTURERS REQUIREMENTS. v SMOKE EXHAUST FAN -\\7„...._________„\\ PARTIAL RISER DIAGRAM PARTIAL RISER DIAGRAM 120/208V 39 400 TE LEG NOS & EN D: 277/480V 3m 400 IN G- BUILDING ONLY. 120/208V 30 4W IN A, B, C, D, E k F- BUILDINGS. NOTES & LEGEND: FOR BUILDING PERMITS 1. BY TENANT 2, BY LANDLORD 3. METER BY UTILITY AT TENANT'S EXPENSE. 4. ALL EQUIPMENT ADDITIONS TO THE METERING /SWITCHBOARD (SOCKET. METER, FUSIBLE SWITCH, CIRCUIT BREAKER. ETC.) SHALL BE COMPATIBLE AND COORDINATED WITH THE SWITCHBOARD MANUFACTURERS REQUIREMENTS. 5. THE INTERRUPTING CAPACITY OF THE METERING SWITCHBOARD OVERCURRENT DEVICES SHALL BE A MINIMUM OF 65.000 RMS AMPERES AT 240V AC. 6. TENANT TO PROVIDE A MAIN DISCONNECTING MEANS WITHIN TENANT'S UNIT. 1. BY TENANT .. BY LANDLORD 3. METER BY UTILITY AT TENANT, EXPENSE. 3. a. ALL EQUIPMENT ADDITIONS TO THE METERING /SWITCHBOARD (SOCKET, METER, FUSIBLE SWITCH, CIRCUIT BREAKER, ETC.) SHALL BE COMPATIBLE AND COORDINATED WITH THE SWITCHBOARD MANUFACTURERS REQUIREMENTS. 5 THE INTERRUPTING CAPACITY OF THE METERING SWITCHBOARD OVERCVRREM DEVICES SHALL BE A MINIMUM OF 35,000 RMS AMPERES AT 4800 AC. OR 65,000 RMS AMPERES AT 240V AC. 6. TENANT TO PROVDE A MAIN DISCONNECTING MEANS WITHIN TENANT'S LINO. 24 24 RE5ISTERLINE PARTIAL RISER DIAGRAM 120/208V 3m 4W NOTES & LEGEND: III II // MAGNETIC FAN �STARiER WW� OVERLOADS 24 V C NTRL O CIRCUIT I 1. BY TENANT MAW 2. BY LANDLORD 3. METER BY UTILITY AT TENANTS EXPENSE. 4. ALL EQUIPMENT ADDITIONS TO THE METERING /SWITCHBOARD (SOCKET, METER, FUSIBLE SWITCH, CIRCUIT BREAKER, ETC.) SHALL BE COMPATIBLE AND COORDNATED WITH THE SWITCHBOARD MANUFACTURERS REQUIREMENTS. The Richard E. Jacobs Group S 5. THE VERCUREN7 DEVI INTERRRUPTING CES SHAL CAPACITY L OF BE A THE MINIML'METERA <. ING O 65.0 00 RMS O U' AMPERES AT 20V AC. m -15 f1- 1= FDSCS OUTPUT H F , FDSCS INPUT 2+ 2 + 24 ■ ;424 ' 1 I ' \...TE PANEL - 120 /ZIT V 11111111111 6. TENANT TENANTS PROVIDE MAIN DISCONNECTING MEANS i I o -_ RESET TEST -�' H CEILING SMOKE u - SWITCH DETECTOR FIRE DETECTION & SMOKE CONTROL SYSTEM DIAGRAM 1. ALL WIRING TO BE IN CONDUIT 2. ELECTRIC AND MECHANICAL CONTRACTOR TO COORDINATE INSTALLATION. 3. ONE REQU (7) IRED PE CEILING R MO3D' UNTE-0' D OF STO SMOKE REFRONT. DETECTOR SMOKE LOCATED DETECTNEAR OR TH E STOREFRONT URCHASED F TO H P FROM THE LANDLORD AND INSTALLED BY THE TENANT AND TIED INTO THE FIRE DETECTOR SYSTEM. _ - .......„ 0 REVISED 1/15/96 Q1 REVISED 7/10/95 l L +RA iii SY. DAM 401 KM= IN THE EVENT THE TENANT IS REQUIPED TO INSTALL AND /OR FURNISH ANY AND ALL EQUIPMENT, WIRING, CONDUIT. ETC. FOR TENANT'S ELECTRICAL SERVICE /INSTALLATION, LANDLORD SHALL HAVE THE RIGHT OF APPROVAL OF ALL EQUIPMENT AND METHODS TO BE UTILIZED PRIOR I 1 -31 -00 TO AND AFTER INSTALLATION OF ALL WORK. LANDLORD'S APPROVAL OF SUCH METHODS AND EQUIPMENT SHALL INCLUDE BUT NOT BE LIMITED TO: LOCATION OF TENANT CONNECTION TO LANDLORD'S OR UTILITY COMPANY'S SERVICE; LOCATION OF THE ROUTING OF ALL CONDUIT; RI IMA �? Y , METHODS AND LOCATION OF SUPPOR OF ALL EQUIPMENT AND CONDUIT FROM LANDLORD'S APPROVED STRUCTURE: HEIGHT OF CONDUIT INSTALLATION (HEIGHT OF CONDUIT ROUTING SHALL BE A MAXIMUM HEIGHT FROM THE FINISHED FLOOR WITH A MINIMUM HEIGHT OF 13' -10 "); �^�. SCNTTEi SIZE Or ALL CONDUITS, WIRE, EQUIPMENT, ETC. REQUIRED TO PROVIDE SERVICE TO TPE TENANT'S PREMISES, AD MANUFACTURERS OF SWITCHES, FUSES, METER SOCKETS, METERS, [USED BUS PLUGS, HANGERS, CONDUIT AD ANY OTUER DEVICES OR EQUIPMENT NECESSARY FOR ' DRAW Mgt INSTALLATION. FAILURE TO OBTAIN LANDLORD'S PRIOR APPROVAL FOR ANY OF THE ABOVE SHALL REQUIRE THE TENANT TO REMOVE ANY NONCONFORMING INSTALLATION OR DEVICE AND REPLACE SAME PER METHODS AND MATERIALS REQUIRED BY LANDLORD. TENANTS CONTRACTORS .... ... - „_..... -. ..., - - - -r nr--,,.- ., -. -.- ..,.. nor I.,o1TTCAI n 000rt/AI CAhAA I /MI, rniz C ACDDCCCAITA TI \/C 001/117 T71 A !on ACTCO IAICTAI ■ ATI,.I Tr., ..,r n,iwi l ni in,. T ',C OI III T orn ion" nnntITACAITC nr TuC IAICT All ATIhAI noino Ill n, CDTAAI(`C nr Tur i =,. ' A PANEL NO. MAIN BUS RATING FED FROM MAIN BREAKER FEEDER CABLE SIZE Description Waste A per phase B C CirC No. Circ No. Watts A per phase B C Description 5 _^ 11111 8 s -^ 11S 10 11 -^ ■ 12 13 -^ -^ 1111 a 14 15 16 1 7 -^ 18 19 - 1111 20 21 ^ -^ . 1111 22 23 24 25 ^ -^ WO i - 26 26 27 28 29 -^ 31 -^ 1111 33 j 40 39 - 41 - 42 TOTAL TOTAL CONNECTED LOAD K.W. LOCATION K.V.A. MOUNTING AMPS MAIN BUS RATING MAIN BREAKER PANEL NO. FED FROM FEEDER CA.BLE SIZE Description Watts A per phase B C Ciro No. arc No. Watts A per phase B C Description I -^ : :: • 11: 2 © - 4 - 6 ME © B 10 -�- •• 12 111111111.1111B - M ® - 1111 17 - ^ 1 8 - -111110 20 -- 21 - . 22 - i n 6 OMEN- m WO 28 ��� ®- �� 30 WNW �� 32 ���® - _ 1111 34 ■• -- -® 38 - - - ®- 11 . 40 42 TOTAL -- TOTAL CONNECTED LOAD K.W. LOCATION K.V.A. MOUNTING AMPS LOAD SUMMARY Connected Demand Description K.W. AMPS K.W. AMPS Lighting (recessed) Li•htin• surface Receptacles Water Heater H.V.A.C. E. i• fans, etc. Miscellaneous (sign) Reserve TOTAL Gross Leasable Area = Watts /Sq.Ft. = SEE NOTE #2 STARLESS STEEL ,.TAMPING RING SOLDER JOINT ROOFING MEMBRANE INSULATION TYPICAL DETAIL - LEAD - BUR N.T.S. GENERAL NOTES GENERAL NOTES 18" MIN. SO. LEAD FLASHING , SEE NOTE GENERAL CONDITIONS AND SPECIAL CONDITIONS OF MA 201 AND TENANT'S GENERAL CONDITIONS REQUIREMENTS SHALL APPLY UNLESS OTHERWISE NOTED. 2. ACTUAL LOCATION AND EXTENT OF LANDLORD'S SERVICES MUST BE FIELD VERIFIED. CHANGES TO CONFORM TO LANDLORD SERVICE LOCATIONS AND INSTALLATION REQUIREMENTS SHALL BE MADE AT NO ADDITIONAL COST TO THE TENANT AND /OR LANDLORD, 3. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED, SCHEDULED AND /OR AS REQUIRED FOR A COMPLETE FINISHED INSTALLATION. A. ALL MATERIALS AND EQUIPMENT SHALL BE COMMERCIAL GRADE AND SHALL BEAR A U.L. LABEL. ALL MATERIALS AND EQUIPMENT SHALL BE NEW. REUSE OF EXISTING SHALL BE PROHIBITED UNLESS SPECIFICALLY APPROVED BY LANDLORD AND ALL CODES. 8. MATERIALS, PRODUCTS AND EQUIPMENT INCLUDING ALL COMPONENTS THEREOF, SHALL BE MEW AND AS SUCH APPEAR ON THE UNDERWRITERS LABORATORIES LIST OF APPROVED ITEMS AND SHALL MEET REQUIREMENTS OF ASTM, IEEE, IPCEA, NEC, NEMA, RLM, CEM AND OTHER RECOGNIZED STANDARDS AND SHALL BE SIZED IN CONFORMITY' WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND OTHER APPUCABLE CODES, WHICHEVER ARE MORE STRINGENT. 4. THE WORD "PROVIDE" AS USED HEREIN MEANS TO FURNISH AND INSTALL A COMPLETE WORKING SYSTEM. 5. ALL WORK TO BE IN ACCORDANCE WITH NEC AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES. WHEREVER THERE IS A CONFUCT, THE MORE STRINGENT REQUIREMENT SHALL APPLY. 6, TENANT'S CONTRACTOR SHALL PAY FOR ALL FEES ASSOCIATED WITH THE CONSTRUCTION OF THE SPACE INCLUDING BUT NOT LIMITED TO UTILITY COMPANY CONNECTIONS, SERVICE AND /OR TAPPING FEES: LOCAL, COUNTY OR STATE SERVICE CHARGES, INSPECTION CHARGES, AND PERMIT FEES: LANDLORD'S CONNECTION FEES. LANDLORD'S UTILITY CHARGES, LANDLORD'S METERING CHARGES, AND /OR LANDLORD'S EQUIPMENT CHARGES. 7. SUBMIT MATERIAL: AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE TENANT'S ARCHITECT FOR APPROVAL. SUBMITTALS SHALL BEAR THE STAMP OF THE ELECTRICAL CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM. DEFICIENCIES AND NON - CONFORMING ITEMS - IF, AT ANY TIME DURING THE TERM OF THE LEASE, LANDLORD DETERMINES THAT TENANT'S EQUIPMENT OR SYSTEM HAS NOT BEEN INSTALLED OR IS NOT OPERATING IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS OR LANDLORD'S REQUIREMENTS, LANDLORD MAY, IN ADDITION TO ANY OTHER RIGHTS AND REMEDIES IT MAY HAVE, AFTER GIVING FNE (5) DAYS WRITTEN NOTICE TO TENANT OF IT'S INTENTION TO DO SO, CORRECT SUCH DEFICIENCIES AS LANDLORD MAY ELECT TO PERFORM FOR AND ON TENANT'S BEHALF. TENANT SHALL REIMBURSE LANDLORD FOR ALL COSTS INCURRED BY LANDLORD FOR THE CORRECTION OF THE DEFICIENCIES PLUS A FIFTEEN PERCENT (LSO) ADMINISTRATIVE CHARGE. THE TOTAL AMOUNT SHALL BE DUE AND PAYABLE TO LANDLORD UPON DEMAND. 9. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING OR CHANNEUNG AND PATCHING REQUIRED FOR ANY WORK UNDER THIS DIVISION. ANY CUTTING SHALL HAVE PRIOR APPROVAL OF LANDLORD. SLEEVES SHALL EXTEND AT LEAST 2" ABOVE FINISHED FLOOR AND ALL SLEEVES, OPENINGS, ETC., THROUGH FIRE RATED WALLS AND FLOORS SHALL BE SEALED AFTER CONDUIT INSTALLATION TO RETAIN THEIR PRE RATINGS, CHANNELING OF FLOORS IS EXPRESSLY FORBIDDEN. CONTRACTORS WILL BE HELD LIABLE, 10. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE FROM LANDLORD'S DESIGNATED LOCATION FOR ALL TEMPORARY POWER AND LIGHTING WITH ALL WIRING AS REQUIRED INCLUDING FURNISHING EXTENSION CORDS FOR HIS OWN USE. ANY TEMPORARY WIRING. FUSES, ETC., SHALL BE REMOVED UPON COMPLETION. TENANT SHALL REIMBURSE LANDLORD FOR TEMPORARY POWER. PROVIDE GROUND FAULT PROTECTION AS REQUIRED BY N.E.C. AND LOCAL CODES. PROVIDE ELECTRICAL SERVICE AS SHOWN ON THE DRAWINGS AND AS SPECIFIED. ALL WORK NOT SPECIFICALLY NOTED AS DENO BY THE L DLORD SHALL BE PROVIDED BY THE ELECTRICAL. CONTRACTOR. CLOSELY COORDINATE ENTIRE NSTA.LATION WITH LANDLORD AS REQUIRED. VENT PIPE FOR PLUMBING VENTS TURN LEAD FLASHING DOWN INTO VENT PIPE A MIN. OF 1" BELOW TOP OF PIPE 4 LB. VIRGIN LEAD NOTES' 1. FOR BALLAST SYSTEMS. REPLACE BALLAST AFTER WORK IS COMPLETED. 2. 4 LB. LEAD FLASHING SHALL BE 1/4" MAX. DIAMETER LARGER THAN PIPE ALL JOINTS TO BE SOLDERED. 3. FLANGE SHALL BE SET BY ROOFER. CONTACT L.L. FOR LIST OF APPROVED ROOFING CONTRACTORS 4. ALL ROOFWORK TO BE ' ERFORMED BY MALL APPROVED ROOFING CONTRACTOR SEE NOTE #2 -� STAINLESS RIS - NG CLAMPING PIPE MOLDED `„I RUBBER ROOFING MEMBRANE INSULATION •• NOTE: NOTES' 1. PRE- MOLDED PIPE SEAL CANNOT BE CUT VERTICALLY TO BE INSTALLED. 2. PRE- MOLDED PIPE SEAL MUST HAVE INTACT RIB AT TOP EDGE REGARDLESS OF PIPE DIAMETER. 3. WHEN PREFABRICATED PIPE SEAL CANNOT BE INSTALLED, USE FIELD FABRICATED PIPE SEAL. SEE ALTERNATE PIPE FLASHING DETAIL. 4. FOR BALLAST SYSTEMS, REPLACE BALLAST AFTER WORK IS COMPLETED. 5. FLANGE SHALL BE SET BY ROOFER. CONTACT L.L. FOR LIST OF APPROVED ROOFING CONTRACTORS 6. ALL ROOFWORK TO BE PERFORMED BY MALL APPROVED ROOFING CONTRACTOR TYPICAL DETAIL - PREMOLDED - RUBBER ROOF N.T.S. PIPE /CONDUIT OR VENT THROUGH ROOF FLASHING DETAILS O N.T.S. TT -9 GENERAL NOTES (CONT'D) 12. MAKE PROVISIONS FOR TELEPHONE SERVICE AS REQUIRED AND AS NOTED HERE IN. 13. CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION WITHIN TENANT'S PREMISES SHALL BE PROVIDED WHERE REQUIRED FOR UTILITY COMPANY WIRES. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE WITH CONDUIT DROP AND PULL WIRE TO ABOVE CEILING. 14. PAINTING OF ELECTRICAL CONDUITS, ETC., IF REQUIRED, WILL BE BY THE TENANT'S GENERAL CONTRACTOR, UNLESS OTHERWISE NOTED. 15. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS THE JOB PROGRESSES, AND UPON COMPLETION SHALL TURN OVER TO THE TENANT AND LANDLORD A 'RECORD SET OF PRINTS SHOWING THESE CHANGES, INCLUDING BUT NOT LIMITED TO ACTUAL MANUFACTURER(S) OF EQUIPMENT INSTALLED, EXACT LOCATIONS OF ALL CONDUIT AND EQUIPMENT WITH THE EQUIPMENTS "AS INSTALLED" SIZES ETC. 16. THE FOLLOWING EQUIPMENT SHALL BE IDENTIFIED WITH ENGRAVED BAKELITE NAMEPLATES AS TO NAME AND /OR FUNCTION: DISTRIBUTION PANELS, LIGHTING PANELS, MOTOR STARTERS, PUSH BUTTON STATIONS, SWITCHES AND CONTROL DEVICES, DISCONNECT SWITCHES, METER SOCKETS, ETC. 17. ALL ELECTRIC WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL, SUCH AS CHANNELS, RODS. ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL RE FASTENED TO STEEL, CONCRETE OR MASONRY, BUT NOT TO PIPING OR OTHER NONSTRUCTURAL ITEMS, INCLUDING JOIST BRIDGING, METAL DECK AND CEIUNG SUSPENSION SYSTEMS. ALL CONDUIT SHALL BE CONCEALED WHERE POSSIBLE. EXPOSED CONDUIT SHALL BE IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES OR BEAMS AND SEPARATED AT LEAST 3 INCHES FROM WATER LINES WHEREVER THEY RUN ALONGSIDE OR ACROSS SUCH LINES. CONDUCTORS SHALL BE IN CONDUIT, DUCTS OR APPROVED RACEWAYS. if "LOCK ON" DEVICES SHALL BE PROVIDED ON NIGHT LIGHT CIRCUITS, TIME CLOCK CONTROLLED CIRCUITS, ALL LIFE SAFETY CIRCUITS AND OTHERS AS MAY BE REQUIRED BY THE LANDLORD AND AUTHORITY HAVING JURISDICTION. 19. GROUND ALL CONDUITS, CABINETS, PANELS, AND OTHER EXPOSED NON - CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ALL PROVISIONS OF THE NEC AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES. 20. TEST FOR GROUNDS, SHORT CIRCUITS AND PROPER FUNCTION OF ALL EQUIPMENT AFTER INSTALLATION IS COMPLETE. FAULTS IN THE INSTALLATION SHALL BE CORRECTED. 21. THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS IS APPROXIMATE AND THE TENANT OR LANDLORD SHALL HAVE THE RIGHT TO RELOCATE ANY OUTLETS OR FIXTURES WITHOUT ADDITIONAL COST TO THE TENANT OR LANDLORD. 22. PROVIDE ANY AND ALL SHIELDING OF ELECTRICAL EQUIPMENT OR DEVICES AS REQUIRED BY N.E.C. OR OTHER STATE AND LOCAL CODES DUE TO WATER CARRYING EQUIPMENT, PIPING OR DEVICES OR DUE TO ANY OTHER CONDITION REQUIRING SAME. 23. ROUTE ELECTRIC POWER AND CONTROL FOR THE ROOF MOUNTED HVAC EQUIPMENT THROUGH A SEPARATE ROOF PENETRATION FOR THE ELECTRIC POWER , AND CONTROL CONDUITS. FLASH PENETRATION PER LANDLORD DETAILS. DO NOT ROUTE CONDUIT THROUGH ROOF CURB. DO NOT DRILL HOLES IN CONDENSATE PAN OR COMPRESSOR /CONDENSER SECTION FLOOR. 24. IT IS THE INTENT THAT THE ENTIRE SCOPE OF WORK SHALL BE COMPLETE '5 EVERY ASPECT AND THAT ANY MATERIAL OR WORK NOT' SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK', SHALL BE FURNISHED. 25. GUARANTEE: A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE CO YEAR FROM DATE OF ACCEPTANCE BY TENANT AND LANDLORD. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S EXPENSE. B. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND /OR INSTALLED BY CONTRACTOR. WATER CUT -OFF MASTIC SPLICING CEMENT LAP SEALANT DO NOT TRIM DECK FLANGE GENERAL NOTES ( CONT'D) MATERIAL SPECS 1. CONDUIT SHALL BE STANDARD STEEL RIGID, IMC OR EMT (THIN WALL) ACCORDING TO CODE REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS. A. MINIMUM SIZES OF CONDUITS SHALL BE 3/4" FOR EMBEDMENT IN CONCRETE AND 1/2" FOR ALL OTHER APPLICATIONS. ELECTRIC METALLIC TUBING (EMT) SHALL BE GALVANIZED OR ELECTRO GALVANIZED. FITTINGS SHALL BE OF THE COMPRESSION TYPE. EMT, IMC OR HEAVY WALL CONDUIT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE SUSPENDED CEILINGS OR CONCEALED IN INTERIOR PARTITIONS. EMT SHALL NOT BE CONCEALED IN POURED CONCRETE SLABS OR WALLS. B. FLEXIBLE METAL CONDUIT MAY BE USED ONLY FOR SHORT FINAL CONNECTIONS FROM J -BOX TO FIXTURES AND EQUIPMENT AS PERMITTED BY CODE AND AS DESCRIBED ABOVE. MAXIMUM LENGTH OF ANY FLEXIBLE CONDUIT SHALL BE 6' -0 ". C. CONDUIT SHALL NOT BE INSTALLED IN OR THROUGH DUCT WORK. D. CONDUIT IN THE CONCRETE SLAB OR UNDERGROUND SHALL BE RIGID GALVANIZED CONDUIT OR SCHEDULE 40 PVC RIGID CONDUIT. STUB -UPS, ABOVE THE FINISHED FLOOR, TO PANELS AND BOXES SHALL BE RIGID STEEL CONDUIT. E. PVC CONDUIT IS NOT ALLOWED UNDER ANY CIRCUMSTANCE IN CEILING OR WALL CAVITIES 2. WIRE SHALL BE SINGLE CONDUCTOR COPPER WITH 600 VOLT INSULATION. #10 AND SMALLER SHALL BE SOLID. #8 AND LARGER SHALL BE STRANDED. MINIMUM WIRE SIZE SHALL BE #12 HOWEVER #16 MAY BE USED FOR CONTROL WIRING. ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. ALL WIRING OF ANY TYPE MUST BE IN CONDUIT. A. GENERAL WIRING SHALL BE THW. (ALUMINUM CONDUCTORS ARE NOT PERMITTED.) B. HVAC CONTROL WIRING SHALL BE 8 - #16 AWG MULTI- COLORED CABLE WITH 600 V INSULATION. C. ROMEO AND BX CABLE ARE NOT PERMITTED. (SEE FLEXIBLE METAL CONDUIT) D. MC CABLE MAY BE USED <25' -0' MAXIMUM). WHEN USED FOR SHORT FINAL CONNECTIONS FROM J -BOX TO LIGHTING FIXTURE 6' -0' IS THE MAXIMUM ALLOWABLE. (WHERE LOCAL CODE PERMITS) 3. WIRE CONNECTORS SHALL BE EQUAL BY SCOTCHLOCK FOR #8 AND SMALLER AND T & B 'LOCK -TITE" FOR #6 AND LARGER. 4. LIGHTING FIXTURES, INCLUDING LAMPS, SHALL BE FURNISHED - AS INDICATED ON ELECTRICAL PLAN. ELECTRICAL CONTRACTOR SHALL INSTALL ALL FIXTURES AND LAMPS. IN SALES AREAS, FLUORESCENT FIXTURES SHALL HAVE HPF BALLASTS, AND DEEP CELL PARABOLIC LOUVERS. ALL FIRE RATING ENCLOSURES FOR ELECTRICAL LIGHTING FIXTURES AND EQUIPMENT SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. 5. ALL LINE AND LOW VOLTAGE POWER AND CONTROL WIRING INCLUDING TEMPERATURE CONTROL, CONNECTIONS TO MOTORS, DAMPERS, INSTALLATION OF THERMOSTATS, INTERLOCKING, ETC., EXCEPT THAT WHICH IS SPECIFICALLY NOTED AS BEING BY MECHANICAL CONTRACTOR, SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED POWER AND CONTROL INTERLOCK FOR ALL HOOD FIRE SUPPRESSION SYSTEMS. 6. COLOR OF WIRING DEVICES SHALL BE AS SELECTED BY THE ARCHITECT. COVER PLATE SHALL BE STAINLESS STEEL OR SMOOTH THERMOSPLATIC TO MATCH DEVICE COLOR. WIRING DEVICES SHALL BE EQUAL TO "SPECIFICATION GRADES" AS FOLLOWS: A. DUPLEX RECEPTACLES - HUBBELL #5362 & GF5362 B. LIGHTING SWITCHES - HUBBELL #1221 SERIES, 3 -WAY AND 4 -WAY SIMILAR - #1223 AND #1224 RESPECTIVELY. C. INCANDESCENT DIMMERS - LUTRON 0. MANUAL MOTOR STARTERS - SQUARE D TYPE. E. EXHAUST FAN TIMERS - MARK TIME F. CLOCK RECEPTACLE - HUBBELL CAT. 7707 -SS G. SHUNT TRIP - SQUARE D TYPE. 7. BRANCH CIRCUIT PANELS SHALL BE OF THE BOLTED CIRCUIT BREAKER TYPE WITH OVERALL DOOR, AND TYPEWRITTEN DIRECTORY INSIDE DOOR. TWO OR THREE POLE BREAKERS SHALL BE COMMON TRIP TYPE. LOADS SHALL BE BALANCED WITHIN 10 %. 8. SAFETY AND DISCONNECT SWITCHES SHALL BE FUSED OR NON- WP, POWER DISCONNECT SWITCH (FUSED LIQUIDTIGHT FLEXIBLE CONDUIT (1' -0" MAX. LG.) ROOFTOP UNIT ROOFING FULL PERIM ROOFTOP EQUIPMENT CURB OR CONDENSING UNIT RAIL. RIGID CONDUIT -SIZE AS REQUIRED WP RECEPTACLE POWER & CONTROL CONDUIT ROOF PENETRATIONS. FOR CONTINUATION. SFF DETAIL O9 1. LOCATE SO NOT TO OBSTRUCT ANY SERVICE TO RTU OR READING OF NAMEPLATE 2. DO NOT INSTALL CONDUIT THRU CURES. USE SEPERATE ROOF PENETRATIONS. 3. PITCH POCKETS ARE NOT PERMITTED ROOFTOP UNIT CONDUIT DETAIL NTS TT -37 EXISTING JOIST GENERAL NOTES (CONT'D) 9. OUTLET BOXES AND COVERS SHALL BE GALVANIZED. ONE - PIECE, PRESSED STEEL KNOCKOUT TYPE. 10. JUNCTION BOXES. PULL BOXES AND COVERS SHALL BE GALVANIZED STEEL, CODE GAUGE SIZE. CONTRACTOR TO PROVIDE CEILING ACCESS DOORS FOR CONCEALED JUNCTION OR PULL BOXES. A. FOR NON FOOD COURT TENANTS, TIME SWITCHES SHALL CONTROL SIGN, ENTRANCE LIGHTING, AND SHOW WINDOW LIGHTING. USE PARAGON TYPE 7007 -0 OR EQUAL, 24 HOUR, 7 -DAY TYPE. B. FOR FOOD COURT TENANTS, THE LANDLORD HAS PROVIDED A JUNCTION BOX ABOVE THE CEILING FOR CONTROL OF THE TENANT'S SIGN (120 VOLTS). THE LANDLORD WILL PROVIDE A 1/2' CONDUIT FROM THE JUNCTION BOX TO THE SIGN. WIRING FROM THE JUNCTION BOX TO THE SIGN IS THE TENANT'S RESPONSIBILITY. SEE LANDLORD'S DRAWINGS FOR LOCATION. 12. MANUAL MOTOR STARTERS WITH OVERLOAD PROTECTOR MAY BE USED FOR FRACTIONAL HORSEPOWER MOTORS WHERE AUTOMATIC OPERATION IS NOT REQUIRED. SINGLE PHASE STARTERS SHALL BE SQUARE D OR EQUAL. THREE PHASE STARTERS SHALL BE PROVIDED WITH OVERLOAD DEVICE IN EACH PHASE. LOW VOLTAGE MAGNETIC MOTOR STARTERS SHALL BE USED FOR AUTOMATIC FAN OPERATION. COMBINATION STARTERS, WHEN USED. SHALL CONTAIN FUSIBLE SWITCHES. gco ELECTRICAL DATA FORMS TO BE COMPLETED BY TENANT NOTE THE COOLING AND HEATING LOADS SHALL BE INTERLOCKED SO AS NOT TO OCCURE SIMULTANEOUSLY. THE LARGER OF THE TWO LOADS SHALL BE USED TO DETERMINE THE TOTAL CONNECTED. NOTE: LIGHTING K.W. FROM LOAD SUMMARY TO BE USED IN H.V.A.C. CALCULATION FORM. SDUTHCENTER SYSTEM DESCRIPTION If any part of the tenant's electrical service /Installation Is not existing, tenant shall Install and /or furnish al( equipment, conduit, wiring, etc. from landlord's service (wtreway, switchboard, bus duct, etc.) to the tenant's premises and shall be subject to landlord's prior approval. Tenant to verify on landlord dwgs. and with landlord representative the extent of existing portions of system, system voltage and sizes. Tenant shall Indicate on tenant's plans all design information required for the complete electrical system to be installed. See 'Service Installation Note' on drawing TTE -1 for landlord requirements, 2. The tenant shall Furnish and Install all conduit, cable, equipment, lighting fixtures, panels, transformers, etc. as required for a complete Installation per the National Electrical Code, landlord requirements and the local authority having Jurisdiction, 3. The tenant shall furnish and Install a smoke control system within the premises as noted on TTE and /or TOM drawings. 4. If not installed by the landlord, the tenant shall Install conduit to obtain telephone service from the local utility company. All wiring dncl 1111. installation Is by the tenant and at the tenant's expense. 5. No pane( or flexible conduit shall be located In the dem ISing wa (L.:,,.,, 6. All electrical & telephone equipment shall be located on 1-0/4' plywood panel which shall be mounted to a masonry wall using minimum 1 -5 /B unistrd`t. Unl strut Is not necessary For mount lag plywood to stud walls. SOUTHCENTER Q3 REVISED L S REVISED tISATTl.4 WASHINGTON ELECTRICAL DESIGN CRITERIA, DETAILS AND SPECIFICATIONS Sheet 2 of 2 UNIT NUMBER DBA PHIS SHEET & TTG -01 MUST BE INCLUDED -AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS AND FOR BUILDING PERMITS The Richard E. Jacobs Group DATA 111119 GAMS 1 -31 -00 7/15/98 1/15/96 6/13/95 Job Title O 0 O ■s Tails Camera Southcenter Space F -664 Tukwila, Washington D 0 D N 0 0 ..1111111a 4 4 0 0 0 O ( -2 r Sheet Content ELECTRICAL ROUGH PLAN Revision PERMIT SET - Sr20 /0I 3745 Job Number AR Drawn By REGISTERED ARCCHITE TE' C D C T '�"''�✓' , ` , ' SEA . SHING STATE OF *:A3HINGTON JS Checked By 6 -20 -0I Date 3300 Smith Tower Seattle, Washington 98104 206 622 -4981 Fax: 206 682 -4289 r m m z MESHER SHING& ASSOCIATES ARCHITECTURE SPACE.PLANNING AND a COMMERCIAL INTERIOR °DESIGN H,V,A,C, SCHEDULES SPLIT SYSTEM SPECIFICATIONS MANUFACTURER LtiVOX SATURATED SUCTION TEMP F REFRIGERANT K-2')•• _ qy' Fdb E.E.R. RATING q ?..5 SATURATED COND. TEMP F AIR ENTERING CONDENSER, CONDENSING UNIT AIR HANDLING UNIT EVAPORATOR COIL MODEL NO. W iii -O3(; MODEL NO. EC FX9/M 41 MODEL NO. Cab WEIGHT WEIGHT . IS LAS AIR ENT. COIL � Fdb f23 Fwb VOLTS /PHASE /HZ ' VA9 P' 6t o AIR LVG. COIL SN'.Fdb 53 Fwb COMP PWR INPUT 1./ CFM MID ROWS A. CIRC FINS/ 14 TOTAL COOLING. BTUH TOTAL S.P. . "WC TOTAL COOLING '354OO BTUH FAN RPM HP 3/4- BHP SENSIBLE COOLINGBTUH ACCESSORIES: PRESSURE DROP all, WC LOW LEAKAGE SEALS ON O.A. DAMPERS COIL FACE AREA 4..94 SQ.FT. VELOCITY FILTERS FACE VELOCITY - 4 LS FPM LOW REMARKS: S'2.E4 SEPARATE ELECTRIC DUCT HEATER SPECIFICATION // MANUFACTURER G- ENr KW 10 STEPS ' VOLTS /PHASE /HZ VSISNT ,C94Q( MODEL NO. TCE ) - 1f7c ACCESSORIES FUSED DISCONNECT SWITCH SLIP -IN MAGNETIC CONTACTORS OTHERS 24V IKANSFORMER ZERO CLEARANCE THERMOSTAT TOILET EXHAUST FAN SPECIFICATION MANUFACTURER CFM WATTS /HP V /PH /HZ MODEL STATIC PRESS. "WC RPM CONNECTION ', K.W. H,V,A,C, CALCULATI ❑N E❑RM PHASE I SUMMER SPACE 76 F @ 50% R.H. OUTSIDE 84 F db/ 68 F wb HEATING SPACE 72 F OUTSIDE 21 F ROOF "U" = 0.08 CLTD = 68 HEAT LOSS I SENSIBLE LATENT HEAT GAIN HEAT GAIN I TEM QUANTITY FACTOR BTUH FACTOR BTUH H FACTOR BTU 1. ROOF AREA G.L.A. 1`1-30 SOFT. 4.28 S'2.E4 5.71 � 707-' 2. CORRIDOR WALL a OUTSIDE WALL 560 SOFT. SOFT. 4,76 17.34 26.65 2.5 )K 1 4 ! p I. 4. LIGHTING HElIE CONNECTION ', K.W. 3413 3413 6)4.3 5 PEOPLE GLA /100 = 11.,. PEOPLE - 250 3d 200 Zx{� 6. APPLIANCES SEE APPLIANCE CALC FORM 7. OUTSIDE AIR GLA x .2 CFM /SO.FT. FM 55.08 13.5 SC 564 9.17S 6.80 16 - 1_ . B. FAN MOTORS 34-H.P. - - .. 1479 2545 ) i j 0 21610 ,.. 4b 73 TOTALS CFM: SENSIBLE BTUH =too CFM TOTAL = (SENSIBLE + LATENT)= "1.5653 BTUH COOLING 1.08x20' AT )IE)IE LIGHTING KW ENTRY SHALL MATCH FROM THE ELECTRIC LOAD SUMMARY ON 'ELECTRICAL DATA FORMS' )S WALL FACTOR OUTSIDE WALLS NORTH= 3.40 REMARKS. EAST =10.88 SOUTH= 5.44 WEST = 3.74 H,V,A,C, C ❑N E❑RM BUILDING '52' SUMMER SPACE 76 ° F @ 50% R.H. OUTSIDE B4 °F dh/ 68°F wb HEATING SPACE 72 °F OUTSIDE 21°F ROOF "U" = 0.09 CLTD = 68 HEAT LOSS SENSIBLE LATENT HEAT GAIN HEAT GAIN ITEM QUANTITY FACTOR BTUH 4.54 FACTOR 5.33 BTUH FACTOR BTUH r" 1. ROOF AREA G.L.A. SQ.F T. 2. CORRIDOR WALL SOFT. 7.65 I 0,75 3. OUTSIDE WALL SQ,FT. 17.34 )1E 4. LIGHTING 1K HA CONNECTION K.W. ti 3413 ' 315 5. PEOPLE GLA /100 = PEOPLE 6. APPLIANCES SEE APPLIANCE CALC FOR 7. OUTSIDE AIR GLA x .2 CFM /SQ.F T.= CFM 55.08 -8,64 2545 6.80 8. FAN MOTORS H.P. TOTALS TOTAL = (SENSIBLE + LATENT)= BTUH COOLING HA HA LIGHTING KW ENTRY SHALL MATCH FROM THE ELECTRIC LOAD SUMMARY ON 'ELECTRICAL DATA FORMS' HA WALL FACTOR OUTSIDE WALLS NORTH= 4.08 REMARKS EAST = 8.84 SOUTH= 6.46 WEST = 6.46 BEARS THE BON DOUBLE NUT WITH 2` O.D. 1/a' THICK WASHER (TYP) 1 /4' MIN. DWAETER CONTINUOUS iHRFADED ISOLATOR MASON SPRIN TYPE SIZE SPRING GR AS SIZE EACH HANGER ASSEMBLY FOR M. CAOCITY OF WEIGH A O THE INSL wElcnr. ALLED METHOD #1 USE THIS METHOD ONLY WHEN SPACE EXISTS BETWEEN ANGLES FORMING BOTTOM CHORD. KEY PLAN NO SCALE DOUBLE NUT WITH l 0 2 G. 1/4' THICK W ASHR (TYP) MIA'. k2'at/4" A SUPPORT ATTACH TO EACH SECURE UNIT (MIN.) LOCATE PER EQUIP MFR. REQUIREMENTS 5 JOIST. O.C. MA%. JOIST. TC ANGLES WHEN HANGER ROO PROJECTS - BEYOND JOIST MORE THAN 6` EXTEND ANGLE TO NEXT JOIST METHOD #7 EQUIPMENT SUPPORT DETAIL 0, N.T.S. 1'T -15 NOTE, 1. FIELD VERITY LANDLORD'S APPROVED LOCATION OF H.V.A.C. EQUIPMENT WITH LANDLORD'S REPRESENTATIVE BEFORE PROCEEDING. 2. SEE STRUCNRE DRAWINGS FOR HVAC. EQUIPMENT AND REINFORCED JOIST LOCATIONS FOR EQUIPMENT 2001. OVER 200/. ]. SIZE Of STRUCTURAL SUPPU`.RYS ( R0D5, ANGLE ETC.) ARE MINIMUMS AND SNARL BE REBRED Y' TENANT OR TENANT CONTRACTOR AS REOUIREO fOR PROPER SUPPORT ANO STRUCTURAL INTEGRITY. 4. DO NOT DRILL HOLES IN EXISTING STRUCTURAL MEMBERS UNLESS APPROVED BY LWOLORD IR! WRMNG. 5. UNLESS INDICATED OTHERWISE ON STRUCTURAL DRAWINGS: A UNITS UP TO 1880 LBS. TOTAL WEIGHT SHALL BE SUPPORTED ON A MINIMUM OF TWO (2) JOISTS. B UNITS GREATER THAN 1880 LBS. BUT LESS THAN 2800 LBS. TOTAL WEIGHT SHALL BE SUPPORTED ON A MINIMUM OF THREE (3) JOISTS. C MAXIMUM TOTAL WEIGHT OF ONE UNIT IS 2800 LBS. CLAMP ANGLE TO JOIST. BOT CHORD OF J 0157 PHASE I A. HVAC SOUTHCENTER MALL PHASE I SYSTEM DESCRIPTIONS 1. TENANT TO FURNISH AND INSTALL SPUT SYSTEM HEATING AND AIR CONDITIONING UNIT(S), SIZED PER SENSIBLE/TOTAL CALCULATION FORM. HEATING SHALL BE ELECTRIC FOR PHASE I TENANTS. GAS IS NOT AVAILABLE. TENANT SHALL CONNECT TO LANDLORD PROVIDED OUTSIDE AIR DUCT WHERE PROVIDED FOR MINIMUM FRESH AIR REQUIREMENTS, OR INSTALL AN OUTDOOR AIR INTAKE THROUGH ROOF. INSULATE DUCTWORK PER LANDLORD'S REQUIREMENTS. WHERE TENANTS ELECTRIC HEATING REQUIREMENT EXCEEDS 6 KW A HEAT PUMP IS NEEDED AS PER WASHINGTON STATE 1994 ENERGY CODE. 2. TENANTS SHALL INSTALL TOILET ROOM INCLUDING EXHAUST FAN AND EXHAUST DUCT UP TO ROOF IXHAUSTER. B. PLUMBING 1. TENANT SHALL FURNISH AND INSTALL A COMPLETE TOILET ROOM WITHIN THE LEASED PREMISES. LANDLORD HAS PROVIDED SANITARY AND DOMESTIC WATER CONNECTIONS FOR TENANTS TO UTILIZE. TENANTS SHALL RUN A 4" VENT THRU ROOF. TOILET ROOMS SHALL CONFORM WITH ADA REQUIREMENTS AND THE REQUIREMENTS OF THE LANDLORD. 2. WATER METER IS REQUIRED BY ALL TENANTS. TENANT TO PURCHASE WATER METER FROM LOCAL UTILITY AND INSTALL PER UTILITY COMPANY REQUIREMENTS. PROVIDE METER WITH REMOTE READOUT AS REQUIRED. ALL INSTALLED EQUIPMENT, ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. C. SPRINKLER TENANT SHALL FURNISH AND INSTALL A SPRINKLER SYSTEM WITHIN THE LEASED PREMISES FROM THE LANDLORD'S CONNECTION POINT. 2. SPRINKLER IS REQUIRED ABOVE CEILING AT ALL ELECTRIC MOTORS AND IN AHU MIXING 80X. 3. ALL DESIGN SHALL BE APPROVED BY ALL AUTHORITIES HAVING JURISDICTION, THE LANDLORD AND FACTORY MUTUAL. THE LANDLORD'S UNDERWRITER IS: FACTORY MUTUAL DISTRICT OFFICE 10900 NE 4th ST. SUITE 700 P.O. BOX 96077 BELLEVUE, WA. (206)- 454 -3931 98009 -9677 D. SMOKE DETECTION SYSTEMS 1. TENANT SHALL INSTALL A SMOKE DETECTOR IN THE SUPPLY AIR SECTION OF THE AIR HANDUNG UNIT(S). 2. UPON DETECTION OF TENANT SMOKE THE SMOKE DETECTOR SHALL SHUT DOWN THE HVAC SYSTEM(S) AND REPORT TO AN UNDERWRITER'S LABORATORIES LISTED CENTRAL STATION MONITOR. 3. PROVIDE REMOTE TEST - ALARM -RESET SWITCH /UGHTS AT REAR DOOR FOR SMOKE DETECTOR A L.E.D. IN SALES AREA CEILING TO NOTIFY M.G.R. WHEN SMOKE DETECTOR IS ACTIVATED. g APPROVED APPROVED AS CORRECTED ❑ REVISE AND RESUBMIT Load calculations reviewed only for compliance with applicable building and mechanical • codes and conformance with standard industry practices. Contractor is responsible for performance, installation, dimensions, quantities, and coordination of the work. KEY PLAN NO SCALE MERVYN'S PLUMBING EVAPORATOR FAN PERFORMANCE CFM EXTERNAL S.P. 'WC MOTOR HP HP OUTSIDE AIR (MIN.) CFM BUILDING 'G2' SOUTHCENTER MALL BUILDING 'G2' SYSTEM DESCRIPTIONS A. HVAC C. 1. TENANT TO FURNISH AND INSTALL ROOF TOP UNIT(S) SIZED PER 1. SENSIBLE/TOTAL CALCULATION FORM. HEATING MAY BE GAS OR ELECTRIC FOR BUILDING "0 -2" TENANTS. GAS IS AVAILABLE ON F O TAIN GAS METER FROM LOCAL UTILITY AND INSTALL TENANT SHALL ALL B LL PER UTILITY COMPANY REQUIREMENTS. SEE 2. LANDLORD'S DRAWINGS FOR GAS METER LOCATION. COOLING SHALL BE ELECTRIC. LOW AMBIENT OR AN ECONOMIZER CYCLE IS REQUIRED ON ALL RTU'S. 3. 2. TENANT SHALL FURNISH AND INSTALL A SMOKE RELIEF. FANS SHALL BE SIZED AS INDICATED ON CALCULATION FORM. TENANTS WITH ECONOMIZER MAY UTILIZE HVAC RELIEF AS SMOKE RELIEF. 1. LANDLORD HAS PROVIDED SANITARY, GAS AND DOMESTIC WATER SERVICES FOR TENANTS TO UTILIZE. SEE LANDLORD'S DRAWINGS FOR LOCATION OF SERVICES. 2. WATER METER IS REQUIRED BY ALL TENANTS. TENANT TO PURCHASE WATER METER FROM LOCAL UTIUTY AND INSTALL PER UTILITY COMPANY REQUIREMENTS. PROVIDE METER WITH REMOTE READOUT AS REQUIRED. ALL INSTALLED EQUIPMENT, ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. H,V,A,C, SCHEDULES ROOFTOP UNIT (RTU) SPECIFICATIONS MANUFACTURER CODLING CAPACITY (AT AR. CONDITIONS) MODEL AIR ENTERING CONDENSER 95 - db VOLTS /PHASE /HERTZ AIR ENTERING EVAPORATOR Fdb/ _Fwb EER RATING TOTAL COOLING CAPACITY BTUH TOTAL WT. LBS. SENSIBLE COOLING CAPACITY BTUH COMPRESSOR INPUT KW HEATING CAPACITY GAS (YES) (NO) INPUT OUTPUT ACCESSORIES ECONOMIZER (YES) (ND) DR LOW AMBIENT CONTROL TO 0 F (YES) (ND) HVAC RELIEF (GRAVITY) (PWR) HP DOWNTURN PLENUM ANTI - SHORT CYCLE TIMER AUTO- CHANGEOVER T'STAT WITH FULL PERIMETER CURB CRANKCASE HEATER HEAT -COOL- AUTO -OFF AND THROWAI'AY FILTERS 5 -YR. COMP. WARRANTY FAN - AUTO -ON- SWITCHES IN SUB -BASE SEPARATE POWERED HVAC /SMOKE RELIEF FAN SPECIFICATION MANUFACTURER CFM V /PH /HZ HP MODEL STATIC PRESSURE 'WC DRIVE (DINECT)OR(BELT) RPM MINIMUM CFM CALCULATIONS LEASABLE AREA x 1.5 CFM /SQ.FT. _ NOTE: MINIMUM STATIC PRESSURE SHALL BE .25' W.C. rN) IVJ CFM SPRINKLER TENANT SHALL FURNISH AND INSTALL A SPRINKLER SYSTEM WITHIN THE LEASED PREMISES FROM THE LANDLORD'S CONNECTION POINT. SPRINKLER IS REQUIRED ABOVE CEILING AT ALL ELECTRIC MOTORS AND IN AHU MIXING 80X. ALL DESIGN SHALL BE APPROVED BY ALL AUTHORITIES HAVING JURISDICTION, THE LANDLORD AND FACTORY MUTUAL. THE LANDLORD'S UNDERWRITER IS: FACTORY MUTUAL DISTRICT OFFICE 10900 NE 4th ST. SUITE 700 P.O. BOX 96077 BELLEVUE, WA. (206) 454 - 3931 98009 - 9677 SMOKE DETECTION SYSTEMS TENANT SHALL INSTALL A SMOKE DETECTOR IN THE SUPPLY AIR SECTION OF THE ROOF TOP UNIT(S). 2. UPON DETECTION OF TENANT SMOKE THE SMOKE DETECTOR SHALL SHUT DOWN THE HVAC SYSTEM(S), SOUND AN AUDIO/VISUAL ALARM HORN LOCATED AT THE FRONT OF THE STORE AND REPORT TO AN UNDERWRITER'S LABORATORIES USTED CENTRAL STATION MONITOR. 3. PROVIDE REMOTE TEST -ALARM -RESET SWITCH /UGHTS AT REAR DOOR FOR SMOKE DETECTION SYSTEM. J T5 REVISED 2n REVISED L� REVISED DRAWING NUMBER: SOUTHCENTER SEATTLE, WASHINGTON MECHANICAL DETAILS AND SPECIFICATIONS Sheet I of 6 UNIT NUMBER DBA THIS SHEET & TTO•DI MUST BE INCLUDED AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS AND FOR BUILDING PERMITS Jo The Richard E. Jacobs Group REVISIONS DRAM BY: MA1 REVISED BY: FILE NAME: keNlI11il OA IE: JOB NUMBER DATE - -1,1112 2001 a/20/98 1/15/96 6/13/95 H,V,A,C, SCHEDULES ROOFTOP UNIT (RTU) SPECIFICATIONS MANUFACTURER COOING CAPACITY (AT AR. CONDITIONS) MODEL AIR ENTERING CONDENSER 95 FAR VOLTS /PHASE /HERTZ AIR ENTERING EVAPORATOR Fdb/ _Fwb EER RATING TOTAL COOLING CAPACITY BTUH TOTAL WT LBS. SENSIBLE COOLING CAPACITY BTUH EVAPORATOR FAN PERFORMANCE COMPRESSOR INPUT KW CFM HEATING CAPACITY EXTERNAL S.P. 'WC GAS (YES) (NO) MOTOR H P HP INPUT OUTSIDE AIR (MIN.) CFM ACCESSORIES OUTPUT ECONOMIZER (YES) (NO) OR LOW AMBIENT CONTROL TO 0 F (YES) (NO) HVAC RELIEF (GRAVITY) (PWR) HP DOWNTURN PLENUM ANTI -SHORT CYCLE TIMER AUTO- CHANGEOVER T'STAT WITH FULL PERIMETER CURB CRANKCASE HEATER HEAT -COOL- AUTO -OFF AND THROWAWAY FILTERS 5 -YR. COMP. WARRANTY FAN - AUTO -ON- SWITCHES IN SUB -BASE KITCHEN EXHAUST FAN MANUFACTURER MOTOR H.P. CFM POWER V/ HZ PH MODEL FAN R.P.M. E.S.P. DRIVE BELT MOUNTING (CURB) SEPARATE POWERED HVAC /SMOKE RELIEF FAN SPECIFICATION MANUFACTURER CFM V /PH /HZ HP_ MODEL STATIC PRESSURE 'WC DRIVE (DIRECT)OR(BELT) RPM MINIMUM CFM CALCULATIONS LEASABLE AREA x 1.5 CFM /SQ.FT. = CFM NOTE MINIMUM STATIC PRESSURE SHALL BE .25' W.C. H,V:A,C, SCHEDULES ROOFTOP UNIT (RTU) SPECIFICATIONS MANUFACTURER COOLING CAPACITY MODEL AIR ENTERING CONDENSER Edit) VOLTS /PHASE /HERTZ AIR ENTERING EVAPORATOR Fdb/ Fwb EER RATING TOTAL COOLING CAPACITY BTUH TOTAL WT. LBS. SENSIBLE COOLING CAPACITY BTUH EVAPORATOR FAN PERFORMANCE COMPRESSOR INPUT KW CFM HEATING CAPACITY EXTERNAL S.P. 'WC ELECTRIC (YES) (NO) GAS (YES) (NO) MOTOR H P HP KW INPUT OUTSIDE AIR (MIN.) CFM STEPS OUTPUT ACCESSORIES ECONOMIZER (YES) ENO) OR LOW AMBIENT CONTROL TO 0 F (YES) (NO) HVAC RELIEF (GRAVITY) (PWR) HP DOWNTURN PLENUM ANTI -SHORT CYCLE TIMER AUTO - CHANGEOVER T'STAT WITH FULL PERIMETER CURB CRANKCASE HEATER HEAT -COOL- AUTO -OFF AND THROWAWAY FILTERS 5 -YR. COMP. WARRANTY FAN - AUTO -ON- SWITCHES IN SUB -BASE TOILET EXHAUST FAN SPECIFICATION MANUFACTURER CFM WATTS /HP V /PH /HZ MODEL STATIC PRESS. "WC RPM SQ.FT. SEPARATE POWERED HVAC /SMOKE RELIEF FAN SPECIFICATION MANUFACTURER CFM v /PH /HZ HP MODEL STATIC PRESSURE 'WC DRIVE (DIRECT)OR(BELT) RPM MINIMUM CFM CALCULATIONS LEASABLE AREA x 1.5 CFM /SQ.FT. = CFM NOTE MINIMUM STATIC PRESSURE SHALL DC .25 ..C: H,V,A,C: CALCULATION FORM PHASE II SUMMER SPACE 76 ° F @ 5O7. R.N. OUTSIDE 84 °F db/ 68°F wb HEATING SPACE 72 °F OUTSIDE 21°F ROOF "U" = 0.05 CLTD = 68 HEAT LOSS SENSIBLE LATENT HEAT GAIN HEAT GAIN ITEM QUANTITY FACTOR BTUH FACTOR BTUH FACTOR BTUH 1. ROOF AREA G.L.A. SOFT. 2.55 3.4 0.75 2, CORRIDOR WALL SQ.FT. 4.76 2.52 X 3. OUTSIDE WALL SOFT. 2.30 A 3413 315 8.64 4. LIGHTING AX III CONNECTION K.W. 3413 8. FAN MOTORS 5. PEOPLE GLA /100 = PEOPLE 315 325 6. APPLIANCES SEE APPLIANCE CALC FORM IA SIX LISATING KW ENTRY SHALL MATCH FROM THE ELECTRIC LOAD SUMMARY ON 'ELECTRICAL DATA FORMS' 7. OUTSIDE AIR GLA x .2 CFM /SQ.FT.= CFM 8.64 B. FAN MOTORS M.P. 2545 TOTALS TOTAL = (SENSIBLE + LATENT). BTUH COOLING NE BE LIGHTING KW ENTRY SHALL MATCH FROM THE ELECTRIC LOAD SUMMARY ON 'ELECTRICAL DATA FORMS' *WALL FACTOR OUTSIDE WALLS NORTH= 0.50 EAST = 1.00 SOUTH= 0.75 WEST = 1.00 REMARKS■ H,V,A,C, CALCULATION FORM FOOD COURT SUMMER SPACE 76 °F @ 50% R.H. OUTSIDE 84 °F db/ 68°F wb HEATING SPACE 72 °F OUTSIDE 21 °F ROOF "U" = 0.09 CLTD = 68 HEAT LOSS SENSIBLE LATENT HEAT GAIN HEAT GAIN ITEM 1. ROOF AREA QUANTITY G.L.A. SOFT. FACTOR BTUH 4.59 FACTOR 5.33 BTUH FACTOR BTUH 2. CORRIDOR WALL _ SO FT. 7.65 0.75 c _ 3, OUTSIDE WALL SOFT. 17.34 X 4. LIGHTING 31E BE 5. PEOPLE CONNECTION K W GLA /100 = PEOPLE - �" 55.08 3413 315 8.64 - 325 6.80 6. APPLIANCES 7. OUTSIDE AIR SEE APPLIANCE CALC FORM GLA x .2 CFM /SQ.FT= CFM 8. FAN MOTORS H.P. _. 2545 ......�' .. TOTALS TOTAL = (SENSIBLE + LATENT). BTUH COOLING IA SIX LISATING KW ENTRY SHALL MATCH FROM THE ELECTRIC LOAD SUMMARY ON 'ELECTRICAL DATA FORMS' jIR WALL FACTOR OUTSIDE WALLS NORTH= 408 REMARKS. EAST = 8.84 SOUTH= 6,46 WEST = 6,46 NORDSTROM �1 ® =� I_ Ammo' EMU � re111 rmila lf �s RIIIIIII I-- ii KEY PLAN NO SCALE 4 PHASE II A. HVAC SOUTHCENTER MALL PHASE II SYSTEM DESCRIPTIONS 1. TENANT TO FURNISH AND INSTALL ROOF TOP UNIT(S) SIZED PER SENSIBLE/TOTAL CALCULATION FORM. HEATING MAY BE GAS OR ELECTRIC FOR PHASE II TENANTS. GAS IS AVAILABLE ON ROOF. TENANT SHALL OBTAIN GAS METER FROM LOCAL UTILITY AND INSTALL PER UTILITY COMPANY REQUIREMENTS. TENANT SHALL ROUTE GAS SERVICE TO THEIR SPACE AND EQUIPMENT WITHIN THEIR SPACE. SEE LANDLORD'S DRAWINGS FOR GAS SERVICE LOCATION. COOLING SHALL BE ELECTRIC. LOW AMBIENT CONTROL OR AN ECONOMIZER CYCLE IS REQUIRED ON ALL RTU'S. 2. TENANTS SHALL INSTALL TOILET ROOM INCLUDING EXHAUST FAN WITH EXHAUST DUCT TO LANDLORD PROVIDED CENTRAL TOILET EXHAUST SYSTEM. B. PLUMBING ALL INSTALLED EQUIPMENT, ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. C. 2. 1. TENANT SHALL FURNISH AND INSTALL A COMPLETE TOILET ROOM D WITHIN THE LEASED PREMISES. LANDLORD HAS PROVIDED SANITARY AND DOMESTIC WATER CONNECTIONS FOR TENANTS TO UTILIZE. TENANTS SHALL RUN A VENT TO LANDLORD'S VENT 1 SYSTEM. TOILET ROOMS SHALL CONFORM WITH ADA REQUIREMENTS • AND THE REQUIREMENTS OF THE LANDLORD. 2. WATER METER IS REQUIRED BY ALL LARGE WATER USING TENANTS. TENANT TO PURCHASE WATER METER AND INSTALL PER 2 LANDLORD'S REQUIREMENTS. SPRINKLER TENANT SHALL FURNISH AND INSTALL A SPRINKLER SYSTEM WITHIN THE LEASED PREMISES FROM THE LANDLORDS CONNECTION POINT. ALL DESIGN SHALL BE APPROVED BY ALL AUTHORITIES HAVING JURISDICTION THE LANDLORD AND FACTORY MUTUAL. THE LANDLORD'S UNDERWRITER IS: FACTORY MUTUAL DISTRICT OFFICE 10900 NE 4th ST. SUITE 700 P.O. BOX 96077 BELLEVUE, WA. (206) 454 - 3931 98009 - 9677 FIRE DETECTION AND SMOKE CONTROL SYSTEMS (FDSCS) TENANT SHALL INSTALL A SMOKE DETECTOR IN THE SUPPLY AIR SECTION OF THE ROOF TOP UNIT(S) AND AT STORE FRONT. ADDITIONAL SMOKE DETECTOR'S ARE REQUIRED EVERY 30' -0" OPEN STORE FRONT. TENANTS SHALL FURNISH AND INSTALL A SMOKE RELIEF FAN. TENANTS SHALL FURNISH AND INSTALL A STARTER FOR CONTROL OF THE SMOKE RELIEF FAN. 3. TENANT TO FURNISH AND INSTALL A FIRE DETECTION AND SMOKE CONTROL SYSTEM. ALL COMPONENTS TO BE SAME AS LANDLORD'S EXISTING. INTERFACE BETWEEN LANDLORD'S SYSTEM TO SHUT DOWN TENANTS' HVAC SYSTEM AND _ ENERGIZE TENANT'S SMOKE RELIEF FAN. SEE TTE DRAWING FOR SCHEMATIC. SEARS KEY PLAN N NO SCALE MERVYN' HVAC FOOD COURT SOUTHCENTER MALL FOOD COURT SYSTEM 1. TENANT TO FURNISH .AND INSTALL ROOF TOP UNIT(S) SIZED PER SENSIBLE/TOTAL CALCULATION FORM. HEATING SHALL BE GAS FOR FOOD COURT TENANTS. GAS IS "VAILABLE ON ROOF. TENANT SHALL OBTAIN GAS METER FROM LOCAL UTILITY AND INSTALL PER UTILITY COMPANY REQUIREMENTS. SEE LANDLORD'S DRAWINGS FOR GAS METER LOCATION. COOLING SHALL BE ELECTRIC. LOW AMBIENT CONTROL MUST BE UTILIZED. ECONOMIZER NOT PERMITTED. 2. TENANT SHALL FURNISH AND INSTALL A SMOKE RELIEF. FANS SHALL BE SIZED AS INDICATED ON CALCULATION FORM. PLUMBING D. 1. LANDLORD HAS PROVIDED SANITARY, VENT, GAS AND DOMESTIC 1. WATER SERVICES FOR FOOD COURT TENANTS TO UTILIZE. SEE LANDLORD'S DRAWINGS FOR LOCATION OF SERVICES. 2. 2. WATER METER IS REQUIRED BY ALL FOOD COURT TENANTS. TENANT TO PURCHASE WATER METER FROM LOCAL UTILITY AND INSTALL PER UTILITY COMPANY REQUIREMENTS. PROVIDE METER WITH REMOTE READOUT AS REQUIRED. ALL INSTALLED EQUIPMENT, ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE 3. MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. 10 in DESCRIPTIONS C. SPRINKLER TENANT SHALL FURNISH AND INSTALL A SPRINKLER SYSTEM WITHIN THE LEASED PREMISES FROM THE LANDLORD'S CONNECTION POINT. 2. ALL DESIGN SHALL BE APPROVED BY ALL AUTHORITIES HAYING JURISDICTION, THE LANDLORD AND FACTORY MUTUAL THE LANDLORD'S UNDERWRITER IS: FACTORY MUTUAL DISTRICT OFFICE 10900 NE 4th ST. SUITE 700 P.O. BOX 96077 BELLEVUE, WA. (206)- 454 -3931 98009 -9677 SMOKE DETECTION SYSTEMS TENANT SHALL INSTALL A SMOKE DETECTOR IN THE SUPPLY AR SECTION OF THE ROOF TOP UNIT(S). UPON DETECTION OF TENANT SMOKE THE SMOKE DETECTOR SHUT DOWN THE HVAC SYSTEM(S), SOUND AN AUDIO /VISUAL ALARM HORN LOCATED AT THE FRONT OF THE STORE AND REPORT TO AN UNDERWRITER'S LABORATORIES LISTED CENTRAL STATION MONITOR. 3. PROVIDE REMOTE TEST -ALARM -RESET SWRCH /LIGHTS AT REAR DOOR FOR SMOKE DETECTION SYSTEM. SOUTHCENTER ORAw1NG WILBER: SEATTLE, WASHINGTON MECHANICAL DETAILS AND SPECIFICATIONS Sheet 2 of 6 UNIT NUMBER DBA THIS SHEET & TTO.01 MUST BE INCLUDED AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS AND FOR BUILDING PERMITS REVISIONS © REVISED 4/20/98 2\ REVISED 1/15/96 Q REVISED BRAM BY: SCALE: RINSED BY FILE NAME: SCNTTM2 DATE: 6/13/95 JOB NUMBER DATE The Richard E. Jacobs Group H. Ii. PLUMBING ALL YORK SHALL BE PERFORMED IN CONFORMANCE WITH ALL APPL CODES AN➢ LANDLORD'S MINIMUM REQUIREMENTS AS STATE➢: HERIN] IN THE LEASE, AND /OR IN THE TENANT MANUAL CODE REQUIREMENTS, IF MORE RESTRICTIVE THAN LANDLORD REQUIREMENTS, SHALL TAKE PRECEDENCE. AND VICE . GENERAL AND SPECIAL CONDITIONS OF AIA 201 AND TENANT'S GENERAL CONDITIONS REQUIREMENTS SHALL APPLY UNLESS OTHERWISE NOTED. ALL WORK SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE OF WORK BY THE TENANT AND THE LANDLORD. ALL WORK SHALL BE PERFORMED AS INDICATED ON DRAWINGS UNLESS FIELD CONDITIONS REQUIRE MINOR CHANGES TO BE MADE. MINOR CHANGES SHALL BE MADE WITH NO ADDITIONAL COST TO THE TENANT. ACTUAL LOCATIONS OF LANDLORD'S SERVICES MUST BE FIELD VERIFIED. CHANGES TO CONFORM TO LANDLORD'S SERVICE LOCATIONS SHALL BE MADE AT NO ADDITIONAL COST TO THE TENANT AND /OR LANDLORD. MANUFACTURERS' NAMES ON WHICH THIS SPECIFICATION IS BASED INDICATE THE MINIMUM QUALITY OF PRODUCT REQUIRE➢ BY LANDLORD. SUBSTITUTIONS MA.Y BE MA OE TO THOSE SPECIFIED IF DEEMED EQUIVALENT BY LANDLORD. ITEMS NOT SPECIFIED HEREIN SHALL MEET LANDLORD'S APPROVAL IF A CONFLICT OCCURS, THE LANDLORD SHALL RESOLVE SUCH CONFLICT AND THE TENANT'S CONTRACTOR SHALL CONFORM TO THE LANDLORD'S DECISION SUBMIT SHOP DRAWINGS OF ALL MAJOR EQUIPMENT FOR APPROVAL. SUBMITTALS SHALL INCLUDE AIR AND WATER BALANCE REPORTS. AS BUILT DRAWINGS - PREPARE AND SUBMIT TO LANDLORD AND TO TENANT AS BUILT' DRAWINGS INDICATING THE EXACT LOCATION OF ALL DUCTWORK, PIPING, AND ALL EQUIPMENT INCLUDING THE EQUIPMENT'S 'AS INSTALLED' SIZE(S), MANUFACTURER, MODEL NUMBERS AND PERFORMANCE RATINGS. SUPPORTS - EQUIPMENT, PIPING, DUCTWORK, OR ANY OTHER ACCESSORY SHALL NOT BE SUPPORTED FROM LANDLORD'S CEILING, SOFFIT, NEUTRAL PIERS, PIPING, DUCTWORK, METAL ROOF DECK, LATERAL BRACING, BRIDGING, OR CONDUIT. ITEMS SHALL ONLY BE SUPPORTED FROM STRUCTURE WHICH HAS BEEN APPROVED BY LANDLORD FOR SUPPORT, ALL ROOF YORK, PENETRATIONS AND REPAIRS SHALL BE TOTALLY PERFORMED BY ONLY THOSE ROOFING CONTRACTORS APPROVED BY LANDLORD AND SHALL BE PERFORMED AT THE TENANT'S EXPENSE. INSTALLATION OF ALL P. JF MOUNTED EQUIPMENT SHALL BE COORDINATED WITH LANDLORD'S DESIGNATED REPRESENTATIVE. TENANT'S CONTRACTOR SHALL PAY FOR ALL FEES ASSOCIATED WITH THE CONSTRUCTION OF THE SPACE INCLUDING BUT NOT LIMITED TO. UTILITY COMPANY CONNECTIONS, SERVICE AND /OR TAPPING FEES. LOCAL COUNTY, OR STATE SERVICE CHARGES, INSPECTION CHARGES AND PERMIT FEES) LANDLORD'S CONNECTION FEES, LANDLORD'S UTILITY CHARGES,LANDLORD'S METERING CHARGES AND /OR LANDLORD'S EQUIPMENT CHARGES. WHERE THE TENANT ELECTS TO RE -USE, AND THE LANDLORD HAS APPROVED THE RE -USE OR RENOVATION OF AN EXISTING HVAC AND /OR PLUMBING SYSTEM, REPAIR OR REPLACE ALL OR PART OF THE HVAC AND /OR PLUMBING EQUIPMENT TO ENSURE PROPER AND EFFICIENT OPERATION OF THE SYSTEM(S), ENSURE THE HVAC SYSTEM IS CAPABLE OF MAINTAINING TIE SPACE TEMPERATURES WITHIN THE LEASED PREMISES IN ACCORDANCE WITH THE LANDLORD'S, LOCAL, STATE, AND FEDERAL REQUIREMENTS, AND PROVIDE WRITTEN CONFIRMATION TO LANDLORD OF ALL WARRANTIES IMPLIED. TENANT ELECTS NOT TO RE -USE EXISTING EQUIPMENT, CONDUIT, PIPING OR FIXTURES INCLUDING BUT NOT LIMITED TO ANY ROY MOUNTED EQUIPMENT, TENANT SHALL AT TENANT'S EXPENSE REMOVE SUCH PARTS OF THE SYSTEM AND EQUIPMENT NOT BEING RE -USED INCLUDING CURBS AND UTILITY SERVICES TO SUCH EQUIPMENT, CAP ALL PIPING AT LANDLORD MAINS. TENANT SHALL PERFORM ALL NECESSARY REPAIRS TO THE ROOFING SYSTEM AND /OR ADJACENT CONSTRUCTION IN ACCORDANCE WITH THE LANDLORD'S CRITERIA AND DETAILS INDICATED ON LANDLORD'S MECHANICAL DETAILS AND SPECIFICATIONS DRAWINGS. DEFICIENCIES AND NON - CONFORMING ITEMS - IF, AT ANY TIME DURING THE TERN OF THE LEASE, LANDLORD DETERMINES TENANT'S EQUIPMENT OR SYSTEM HAS NOT BEEN INSTALLED OR IS NOT OPERATING IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS OR LANE"ORD'S REQUIREMENTS, LANDLORD MAY, IN ADDITION TO ANY OTHER RIGHTS AND REMEDIES IT MAY HAVE, AFTER GIVING FIVE (5) DAYS WRITTEN NOTICE TO TENANT OF ITS INTENTION TO DO SO, CORRECT SUCH DEFICIENCIES AS LANDLORD MAY ELECT TO PERFORM FOR AND ON TENANT'S BEHALF. TENANT SHALL REIMBURSE LANDLORD FOR ALL COSTS INCURRED BY LANDLORD FOR THE CORRECTION OF THE DEFICIENCIES PLUS A FIFTEEN PERCENT (15Z) ADMINISTRATIVE CHARGE. THE TOTAL AMOUNT SHALL BE DUE AND PAYABLE TO LANDLORD UPON DEMAND. FOR INSTALLATION OF EQUIPMENT, CONTRACTOR SHALL CONFORM TO LANDLORD'S DETAIL DRAWINGS AND MECHANICAL DETAIL AND SPECIFICATIONS DRAWINGS. PLUMBING SERVICES HAVE BEEN PROVIDED FOR TENANT'S USE. TENANT SHALL E %TEND SERYI CES PER TENANT'S AND LANDLORD'S REQUIREMENTS. SEE LANDLORD'S BUILDING DRAWINGS FOR LOCATION. THE LANDLORD HAS PROVIDED A DOMESTIC WATER, SANITARY VENT AND SANITARY SERVICE. THE TENANT SHALL CONNECT TO THE SERVICES. (MANDATORY) TENANT SHALL EXTEND SERVICE PER LANDLORD REW IRENENTS. NO PIPING SHALL BE INSTALLED IN DEMISING WALL. A HANDICAPPED ACCESSIBLE TOILET ROG, IS REQUIRED IN EACH TENANT SPACE, EXCEPT FOOD COURT AND G2 AREA TENANTS. G2 AREA TENANTS WHO ELECT AND ALL NON- FOODCOURT TENANTS WHERE SAME DOES NOT EXIST, FURNISH AND INSTALL A MINIMUM OF ONE WATER CLOSET, ONE LAVATORY, ONE FLOOR DRAIN, ONE 6- GALLON WATER HEATER, AND ALL OTHER REQUIRED MATERIAL AND EQUIPMENT FOR A COMPLETE TOILET ROOM, TOILET ROOMS SHALL BE AS REQUIRED BY APPLICABLE CODES AND ADA. MATERIALS 1. ALL MATERIALS SHALL BE NEW USED MATERIAL SHALL NOT BE PERMITTED, 2. GAS PIPING 0. SCHEDULE 40 BLACK STEEL PIPE WITH MALLEABLE SCREWED FITTINGS INSTALLED PER LANDLORD'S, STATE AND LOCAL AUTHORITIES', AND THE UTILITY COMPANY REQUIREMENTS. GAS COCKS 2' AND SMALLER SHALL BE SCREWED IRON PLUG VALVE 200 PSI, 2 -1/2' AND LARGER SHALL BE IRON FLANGED, PLUG VALVE, 200 PSI. b. PAINT ALL GAS PIPING EXTERIOR TO THE BUILDING, WHICH WAS INSTALLED UNDER THIS CONTRACT, WITH TWO COATS OF DARK BROWN RUST RESISTANT PAINT. PIPE SHALL BE CLEANED PRIOR TO PAINTING. c. GAS PIPING ON ROOF SHALL BE INSTALLED AND SUPPORTED PER DETAILS. d THERE SHALL BE NO VALVES OR UNIONS INSTALLED IN RETURN AIR PLENUMS. BURIED UNDERGROUND AND BELOW FLOOR SEVER AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON PIPE WITH APPROVED COMPRESSION JOINTS. UNDERGROUND SEVER PIPING SHALL BE A MINIMUM SIZE OF 2', MINIMUM OF 1 /8' PER FOOT OF SLOPE. NO- HUB JOINTS ARE NOT PERMITTED. 3a. UNDERGROUND SEWER PIPING AND FITTINGS MAY BE PVC -DWV ASTM- D2665 -78 SCHEDULE 40 WITH SOLVENT WELDED JOINTS. UNDERGROUND SEWER PIPING SHALL pc A MINIMUM SIZE OF 2', MINIMUM OF I /8' PER FOOT OF SLOPE. L,A ABOVE GROUND, ABOVE OR BELOW FLOOR, SEWER AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON PIPE WITH NO HUB JOINTS. PVC AND ABS PIPING ARE NOT PERMITTED. UNDERGROUND AND BELOW FLOOR HOT AND COLD WATER PIPING SHALL BE TYPE 'K' COPPER PIPE OR TUBING WITH SIL -FOS 15 SILVER BRAZED JOINTS. ABOVE FLOOR HOT AND COLD WATER PIPING SHALL BE TYPE 'L' COPPER PIPE WITH 95 -5 SOLDERED JOINTS OR SIL -FOS 15 SILVER BRAZED JOINTS. INSULATE ALL ABOVE GROUND, ABOVE OR BELOW FLOOR, HOT AND COLD WATER PIPING WITH A MINIMUM OF 1' THICK FIBERGLASS PIPE INSULATION WITH A VAPOR BARRIER AND PLENUM RATED PRE- MOLDED FITTING COVERS OR 1' .THICK CLOSED CELL PIFNLM•RATED INSULATION. INSULATE ALL SANITARY LINES SERVING TENANT SPACE WHEN REQUIRED TO PREVENT CONDENSATION RESULTING FROM TENANT'S OPERATION. ALL JOINTS SHALL BE INSULATED AND SEALED WITH VAPOR BARRIER CEMENT. ALL INSULATION, VAPOR BARRIERS, PRE - MOLDED FITTING COVERS, ETC. SHALL HAVE SURFACE BURNING CHARACTERISTICS NOT EXCEEDING A FLAME SPREAD RATING OF 25 AND A SMOKE DEVELOPED RATING OF 50. FURNISH AND INSTALL DIELECTRIC UNIONS FOR DISSIMILAR PIPING MATERIALS, ALL BACKE./ PREVENTIRS, VALVES, UNIONS, BYPASS PIPING AND TESTING AS REQUIRED BY THE FIXTURE MANUFACTURER, BY THE LOCAL UTILITY AND CODES. PROVIDE ACCWABLC SUPPORTING DEVICES FOR ALL PIPING. ALLOY FOR PIPE EXPANSION AND PREVENTION OF ELECTROLYSIS. SUPPORTING DEVICES NOT PROTECTED WITH A SHOP PLATING /FINISH SHALL BE COATED VITH A RUST INHIBITING PRIMER. SUPPORT PER CFICMIO RFD:HP:RENT, FOR >ONF D. E. F. E. CONNECT TO LANDLORD'S SANITARY AND COLD WATER PIPING AT LANDLORD'S POINT OF SERVICE CONNECTION. PHASE I AND FOOD COURT TENANTS SHALL CONNECT TO LANDLORD SUPPLIED SANITARY VENT SYSTEM, WHERE ADDITIONAL POINTC S) OR INCREASED SIZE OF SERVICE IS REQUIRED (AND APPROVED BY LANDLORD) EMPLOY LANDLORD'S CONTRACTOR TO PERFORM THE WORK PER THE LANDLORD'S CRITERIA AT NO EXPENSE TO LANDLORD. SEE PLAN FOR LOCATION, F. ALL TENANT WORK PERFORMED ABOVE THE CEILING OF OTHER TENANTS SHALL BE COORDINATED VITH OTHER TENANTS) AND LANDLORD. G. AIR CHAMBERS ARE REQUIRED ON EACH HOT AND COLD WATER SUPPLY TO EACH PLUMBING FIXTURE OR PROVIDE SYSTEM SHOCK ABSORBERS SIMILAR TO J. R. SMITH 'HYDROTROL' SERIES 5000. SIZE AS REQUIRED BY TENANT PLUMBING SYSTEM. H. 8. 10. GAS METER 11. ALL FOOD TENANTS AND ANY HIGH HAZARD TENANT SHALL FURNISH AND INSTALL A REDUCED PRESSURE BACKFLOY PREVENTER. 12. WHERE REQUIRED BY LOCAL AUTHORITIES AND UTILITIES ALL TENANTS SHALL INSTALL BACKFLOV PREVENTION. PLUMBING FIXTURES - THE FOLLOWING IS A MINIMUM SPECIFICATION FOR FIXTURES. INTERCEPTORS a. GREASE INTERCEPTOR SHALL BE INSTALLED WHERE REQUIRED BY STATE AND LOCAL CODES AND LANDLORD'S REQUIREMENTS TO RECEIVE GREASE LADEN WASTE. TENANTS SUBMITTAL DRAWINGS SHALL STATE INTERCEPTOR FLOW CAPACITY IN G. P.M. AND POUNDS OF GREASE STORAGE. FLOW CAPACITY AND POUNDS OF GREASE STORAGE SHALL BE CALCULATED PER THE GREASE TRAP MANUFACTURER'S GUIDELINES. CONT- RACTOR SHALL VENT ALL FIXTURES DRAINING TO GREASE TRAPS AND THE GREASE TRAP. b. GREASE INTERCEPTOR SHALL BE CAST IRON J. R. SMITH 8000 SERIES, COMPLETE VITH FLOW CONTROL. INSTALL IN LOCATION AND METHOD APPROVED BY LANDLORD AND THE LOCAL PLUMBING AND HEALTH DEPARTMENT CODES. WORK SINKS FOR HAIR SALONS, PET SHOPS, AND EYEGLASS LABORATORIES. INTERCEPTORS SHALL BE EQUAL TO J.R. SMITH 8700 SERIES. 2. FOOD PREPARATION PLUMBING FIXTURES SHALL BE STAINLESS STEEL AN SHALL BE FURNISHED, INSTALLED ANO CONSTRUCTED TO CONFORM TD D ALL CODES, HEALTH DEPARTMENT, AND NATIONAL SANITATION FOUNDATION. 3. WATER CLOSET - AMERICAN STANDARD 2108.408 CADET VITH CHROME SUPPLY AND STOP VALVE, AND OPEN FRONT WHITE SEAT AND SEAT COVER. SET AT ADA HEIGHT. LAVATORY - AMERICAN STANDARD 9140,011 WHEEL CHAIR LAVATORY 27 X 20' WITH WALL HANGERS, CHROME SUPPLIES AND STOPS, AND 1 -1/2' CHROME TRAP WITH CLEANOU. FURNISH WITH CENTER SET r AUCET, SELF CLOSING WITH FLOW REGULATION, AMERICAN STANDARD OR EQUAL, CHROME PLATED WITH 7723.018 GRID DRAIN /OFFSET TAIL PIECE. 5. WATER HEATER .(MINIMUM) - A.O. SMITH - 6 GALLON, 1500 WATTS INSULATED PER ENERGY CODE. TLP VALVE SHALL BE PIPED FULL SIZE AND SAFEWASTED TO A DRAIN PAN OR FLOOR DRAIN. HEATER SHALL HAVE A 5 -YEAR WARRANTY. 6. WATER HEATERS SHALL CONFORM TO ALL ENERGY CODES AND SHALL INCORPORATE A 2- GALLON THERMAL EXPANSION TANK. HEATER SHALL BE ELECTRIC OR GAS FIRED AND. SHALL INCORPORATE A TEMPERATURE - PRESSURE RELIEF VALVE PIPED TO A FLOOR DRAIN. 7. WHERE WATER HEATERS ARE INSTALLED ABOVE THE FINISHED CEILING, INSTALL HEATERS IN A 3' DEEP WATER TIGHT PAN VITH RELIEF VALVE PIPED TO PAN AND PAN SAFE MASTED TO AN APPROVED FLOOR DRAIN. GAS FIRED WATER HEATERS SHALL NOT BE INSTALLED IN CONCEALED SPACES AND SHALL BE LOCATED IN A SEPARATE ROOM. PROVIDE COMBUSTION AIR FOR GAS FIRED WATER HEATERS WITHIN A ZERO TO POSITIVE PRESSURE ENVIRONMENT. INSTANTANEOUS UNDERSINK TYPE WATER HEATERS ARE ALSO ACCEPTABLE. BAN➢ SINKS, FAUCETS AND SPECIALTIES SHALL % FURNISHED AND INSTALLED PER HEALTH DEPARTMENT REQUIREMENTS AND ALL APPLICABLE CODES. FLOOR DRAIN - J. R. SMITH FIGURE 2010 - WITH A NICKEL BRONZE OR SATIN BRONZE FINISH VITH PRIMER TAPPING WHEN REQUIRED. FLOOR DRAINS SERVING ALL SODA DISPENSER WASTE LINES SHALL BE PROVIDED WITH TRAP PRIMERS CLEANOOTS - J.R. SM1 TN 4000 SERIES VITH CKEL BRONZE OR SATIN BRONZE FINISH TOP AN➢ TAPER THREAD NI BRONZE PLUG OF SIZES SHOWN ON PLANS. ALL CLEANOUTS SHALL BE INSTALLED IN FINISHED FLOOR DR ABOVE. CLEANDUTS UNDER SLAB ARE NOT ACCEPTABLE. TRAP SEAL PRIMER VALVE - J. R. SMITH FIGURE 2699. 12. WATER METER III. FIRE SUPPRESSION SYSTEMS GAS METER - PHASE I - NOT APPLICABLE GAS METER - 'G2' - PHASE II - FOOD COURT WHERE GAS IS REQUIRED BY TENANT'S APPROVED DESIGN, INSTALL AT NO EXPENSE TO LANDLORD, A GAS METER COMPLETE WITH REGULATOR(S), SHUT OFF VALVES, UNIONS AND ALL OTHER ACCESSORIES PER LOCAL UTILITY COMPANY. LOCATE METER AS DIRECTED BY LANDLORD AND UTILITY. a. PHASE 1, G2 AND FOOD COURT - INSTALL AT NO EXPENSE TO LANDLORD, A WATER METER IN AN APPROVED LOCATION PER THE LOCAL WATER UTILITY COMPANY AND LANDLORD'S REQUIREMENTS. CONTRACTOR SHALL PAY ALL FEES AND LANDLORD CHARGES ASSOCIATED WITH METER AND METER INSTALLATION. PHASE II - WATER SUB -METER IS REQUIRED ONLY BY LARGE WATER CONSUMING TENANTS. WATER METER TO BE INSTALLED BY TENANT COMPLETE WITH UNIONS AND SERVICE VALVES. TENANT TO PURCHASE AND INSTALL BADGER MODEL SC -ER OR APPROVED EQUAL, DIGITAL READ OUT IN CU. FT. LOCATE METER 4' -6' AFF IN AREADILY ACCESSIBLE LOCATION. A. TENANT'S SPRINKLER SYSTEM SHALL BE INSTALLED FROM LANDLORD'S SPRINKLER BULK MAIN SERVICE PROVIDED BY LANDLORD FOR THE PREMISES IN THE EVENT A SPRINKLER SYSTEM EXISTS, MODIFY THE EXISTING SYSTEM. IN THE EVENT TENANT REQUIRES LARGER SPRINKLER SERVICE, TENANTS CONTRACTOR SHALL EMPLOY LANDLORD'S CONTRACTOR TO INSTALL INCREASED SIZE OF SERVICE PER LANDLORD REQUIREMENTS. THERE SHALL BE ONLY ONE CONNECTION PER TENANT. THERE SHALL BE NO CROSS FEEDS TO OTHER TENANTS OR MALL SYSTEMS. PROVIDE A SPRINKLER SYSTEM FOR THE ENTIRE PREMISES INCLUDING ALL PIPING AND ACCESSORIES PER THE REQUIREMENTS OF ALL APPLICABLE CODES, FACTORY MUTUAL, NFPA -13, LANDLORD AND LANDLORD'S FIRE AND CASUALTY INSURER. ALL PIPING SHALL RE HYDRAULICALLY DESIGNED AND INSTALLED PER NFPA -13 ORDINARY HAZARD, CLASSIFICATION GROUP II. HYDRAULIC CRITERIA FOR SYSTEM DESIGN SHALL BE DENSITY - 0.18 GPM PER SO. FT, - FIRE AREA - MOST REMOTE 25000 SIFT. WITH A 500 GPM HOSE ALLOWANCE, OBTAIN FLOW AND PRESSURE FROM LOCAL AUTHORITIES OR LANDLORD'S INSURANCE UNDERWRITER. PIPING SHALL BE PER NEPA, OR IF MORE STRINGENT FM APPROVED. MAXIMUM SPACING OF SPRINKLER HEADS SHALL BE 130 SOFT. PER HEAD IN SALES AREA AND 100 SOFT. PER HEAD IN STORAGE AREAS OR HIGH HAZARD AREAS. SPRINKLER HEADS IN THE SALES AREA SHALT. BE CONCEALED /FLUSH OR SEMI- RECESSED PENDANT WITH AN ESCUTCHEON. SPRINKLER HEADS IN STOCK ROOM SHALL BE RECESSED OR UPRIGHT, BRASS OR CHROME. SPRINKLER HEADS IN CONTROL AREA (STOREFRONT POP -OUT) SHALL BE CONCEALED /FLUSH TYPE, FACTORY PAINTED TO MATCH CEILING COLOR. TEMPERATURE RATINGS SHALL BE AS REQUIRED BY LANDLORD'S FIRE AND CASUALTY INSURER AND /OR AUTHORITY HAVING JURISDICTION. ALL SPRINKLER HEADS MUST BE UNDERWRITER'S LABORATORIES LISTED AND FACTORY MUTUAL APPROVED. Q CONTRACTOR SHALL OBTAIN FROM LANDLORD THE LANDLORD'S FIRE AND CASUALTY INSURERS NAME, ADDRESS, AND PROJECT INDEX NUMBER. PRIOR TO INSTALLATION, CONTRACTOR SHALL SUBMIT SEVEN (7) SETS OF CALCULATIONS AND SEVEN (7) SETS OF PRINTS OF SPRINKLER DESIGN TO LANDLORD'S FIRE AND CASUALTY INSURER FOR APPROVAL. UPON APPROVAL AND PRIOR TB INSTALLATION, CONTRACTOR SHALL FORWARD ONE (1) REPRODUCIBLE SEPIA OF THE APPROVED DESIGN AND TWO (2) BLUE LINE PRINTS, WHICH SHALL HAVE -THE LANDLORD'S INSURER'S APPROVAL STAMP, TO THE LANDLORD FOR LANDLORD'S APPROVAL AND RECORDS. CONTRACTOR TO OBTAIN ALL OTHER APPROVALS FROM APPLICABLE AUTHORITIES AND SUBMIT APPROVED � I1 PIj 1 Ip R I' `�ji ({ li � a, Il Pw1 . P 111 ] i , Ili i A i MLH• i* / HR IV. HVAC A. G. G. REIMBURSE LANDLORD FOR ALL COSTS OF DRAINING AND REFILLING LANDLORD'S SPRINKLER SYSTEM WHERE SAME IS REQUIRED TO COMPLETE TENANT'S SPRINKLER SYSTEM. ALL OTHER CODE OR LANDLORD REQUIRED FIRE PREVENTION SYSTEMS AND ACCESSORIES SHALL BE INCORPORATED AS PART OF THIS SCOPE O< WORK. TENANT'S SPRINKLER PIPING 4' AND LARGER SHALL BE INSTALLED WITH HANGERS AT EVERY BAR JOIST WHEN INSTALLED PERPENDICULAR TO BAR JOISTS, AND WITH HANGERS SUPPORTED FROM TWO BAR JOISTS EVERY 10' -0' ON CENTERS WHEN INSTALLED PARALLEL TO BAR JOISTS. ALL HELLS PANEL SUPPORTS SHALL BE INSTALLED WITHIN 6' OF A JOIST PANEL POINT. THE MALL MANAGEMENT, THE LANDLORD'S FIRE AND CASUALTY INSURER, AND THE LOCAL FIRE DEPARTMENT MUST BE NOTIFIED AT LEAST 40 HOURS PRIOR TO MAKING ANY MODIFICATIONS TO THE EXISTING FIRE PROTECTION SYSTEMCS). WORK SHALL BE COORDINATED SO THAT ONLY ONE (1) RISER OR BULKMAIN IS SHUT -DOWN FOR ANY GIVEN TIME. SPRINKLER SYSTEM(S) SERVICE SHALL BE RESTORED TO THE AREAS AFFECTED AT THE END OF EACH WORKING DAY DURING THE CONSTRUCTION PERIOD. K. PIPING TEST - ALL ABOVE GRADE PIPING INSTALLED BY THIS CONTRACTOR SHALL BE TESTED AT A PRESSURE OF 200 LBS. HYDROSTATIC FOR TWO (2) HOURS AND ALL NOTICEABLE LEAKS TO BE REPAIRED UNTIL TIGHT. TEST SHALL BE WITNESSED BY THE OWNER'S REPRESENTATIVE AND WRITTEN CERTIFICATION OF SUCCESSFUL TESTING SHALL BE SUBMITTED TO THE ENGINEER PRIOR TO FINAL ACCEPTANCE. THIS CONTRACTOR SHALL ALSO BE REQUIRED TO PERFORM ALL OTHER TESTS REQUIRED BY THE PREVIOUS SPECIFIED AGENCY HAVING AUTHORITY. L. EXHAUST HOODS WHERE REQUIRED BY CODES AND /OR LANDLORD'S PROPERTY AND CASUALTY INSURER(S), SHALL INCORPORATE AN APPROVED AUTOMATIC FIRE SUPPRESSION SYSTEM(S) COMPLETE WITH FAN INTERLOCK, AUTOMATIC GAS APPLIANCE SHUT -OFF SOLENOID VALVE, ELECTRICAL INTERLOCK(SHUNT TRIPS), MANUAL RELEASES, ETC., PER APPLICABLE CODES, NFPA,AND /OR LANDLORD'S FIRE AND CASUALTY INSURER(S). TOY STORES AND OTHER STORES THAT HAVE HIGH PILED STORAGE OF PLASTIC MATERIAL AS DETERMINED BY THE LOCAL FIRE MARSHALL AND /OR LANDLORD'S FIRE AND CASUALTY INSURER SHALL BE DESIGNED FOR .3 GPM PER SO. FT. OVER THE MOST REMOTE 3000 SQ. FT. VERIFY REQUIREMENTS. TENANT HVAC SYSTEM CRITERIA L TENANT SHALL DESIGN, FURNISH AND INSTALL A COMPLETE HVAC SYSTEM TD HEAT AND COOL THE ENTIRE PREMISES IN STRICT CONFORMANCE WITH THE CRITERIA AND DESCRIPTION CONTAINED ON LANDLORD'S MECHANICAL DETAIL AND SPECIFICATION DRAWINGS, THE LEASE AND /OR TENANT MANUAL./ 2. THE HEATING AND COOLING SYSTEM DESIGN SHALL BE BASED ON THE APPLICABLE STATE AND LOCAL CODE(S) AND THE INFORMATION PROVIDED ON THE ATTACHED CALCULATION FORM, WHICH IS DERIVED FROM THE MOST RECENT DESIGN CONDITIONS LISTED IN THE AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR - CONDITIONING ENGINEERS, (A, S. H, R. A. E.) MANUAL. 3. HEAT GAIN CALCULATIONS SHALL BE BASED UPON THE MONTH, DAY AND HOUR OF PEAK SOLAR, THERMAL AND INTERNAL HEAT GAINS USING CODE REQUIRED MINIMUM OUTSIDE AIR QUANTITIES AT DESIGN CONDITIONS. HEAT LOSS CALCULATIONS SHALL BE BASED UPON THE FULL HEAT LOSS AND CODE REQUIRED MINIMUM OUTSIDE AIR REQUIREMENTS AT DESIGN CONDITIONS (CREDIT SHALL NOT BE TAKEN FOR INTERNAL HEAT GAINS). 5. THE FOLLOWING SHALL BE APPLICABLE TO THE CALCULATIONS FOR SPECIAL OCCUPANCIES (E.G., BEAUTY SALONS, PET SHOPS, BARBER SHOPS, GAME OR AMUSEMENT FACILITIES, PHOTOFINISHING ESTABLISHMENTS, RESTAURANTS, ETC.) a. CODE REQUIRED OCCUPANCY LEVEL. b. CODE REQUIRED OUTSIDE AIR QUANTITIES. c. ALL HEAT PRODUCING GAS OR ELECTRIC APPLIANCE LOADS WITH LANDLORD APPROVED DIVERSITY FACTORS. N. LANDLORD MAKE -UP AIR REQUIREMENTS. ALL MAKEUP AIR MUST BE CONDITIONED. 6 FOOD TYPE OR OTHER ODOR PRODUCING TENANT'S HVAC SYSTEM SHALL MAINTAIN A SLIGHT NEGATIVE PRESSURE DIFFERENTIAL BETWEEN THE PREMISES AND THE ENCLOSED MALL AND OTHER COMMON AREAS OF THE SHOPPING CENTER. 7. NON -ODOR PRODUCING TENANT'S HVAC SYSTEM SHALL MAINTAIN A SLIGHT POSITIVE PRESSURE DIFFERENTIAL BETWEEN THE PREMISES AND THE ENCLOSED MALL AND OTHER COMMON AREAS OF THE SHOPPING CENTER. 8. UNLESS OTHERWISE PERMITTED BY LANDLORD, OUTSIDE AIR, RELIEF AIR, EXHAUST AIR OR ANY OTHER TYPE OF OPENING OR GRILLE SHALL NOT BE PERMITTED IN OR ON ANY DEMISING PARTITION, SERVICE CORRIDOR WALL OR EXTERIOR WALL OF THE PREMISES OR EXTERIOR WALL GF THE SHOPPING CENTER. TENANT HVAC SYSTEM a. PHASE II, G2 AND FOOD COURT - WHERE A HVAC UNITCS) IS TO BE REPLACED OR, WHERE A NEW INSTALLATION IS REQUIRED BY TENANTS, THE HVAC SYSTEM SHALL BE FURNISHED AND INSTALLED CONSISTING OF A GAS OR ELECTRIC HEATING /ELECTRIC COOLING ROOFTOP UNITCS) TO SERVE THE ENTIRE PREMISES. EQUIPMENT SHALL BE EDUAL TO CARRIER, TRANS, OR YORK. PHASE II TENANTS SHALL CONNECT TO LANDLORD'S TOILET EXHAUST DUCT. PHASE I - TENANTS SHALL INSTALL A SPLIT SYSTEM. AIR CONDITIONER, WITH ELECTRIC DUCT HEAT, LOCATED IN AREAS DESIGNATED ON LANDLORD DRAWING THE UNIT .;HALL BE CONNECTED TO THE LANDLORD'S MINIMUM avow AIR DUCT WHERE PROVIDED. THE AIR HANDLING UNIT SHALL BE MODULAR, FACTORY ASSEMBLED, DRAW THRU AND SUPPORTED FROM STRUCTURE ONLY IN AREAS APPROVED BY LANDLORD AND PER LANDLORD DETAILS. THE CONDENSER UNIT SHALL BE ROOF MOUNTED AND SUPPORTED BY CURB AT LANDLORD'S DESIGNATED LOCATION, REFRIGERANT PIPING SHALL BE ROUTED THROUGH LANDLORD DESIGNATED CHASES AND DOCUMENTED IN DESIGN DRAWINGS. CONDENSATE SHALL BE RUN TO L L. PROVIDE CONDENSATE DRAIN IN CORRIDOR, WHEN PROVIDED, OR TO TENANTS SANITARY SEWER OR PUMPED T L. L. APPROVED S ❑ EVER. TENANT EN NT SEAL' � ROUTE AS APPROVED BY L. L. PHASE I - FOOD COURT - FOOD TENANTS AND ODOR PRODUCING TENANTS - LOW AMBIENT CONTROL OF MECHANICAL COOLING DOWN TO 0 DEGREES F. AMBIENT TEMPERATURE IS REQUIRED ON ALL FOOD, FOOD COURT OR ODOR PRODUCING TENANT ROOFTOP HVAC SYSTEMS AND ALL PHASE I SPLIT SYSTEMS. POWERED EXHAUST IS REQUIRED FOR FOOD AND ODOR PRODUCING TENANTS. PHASE II - NON FOOD TENANTS - LOW AMBIENT CONTROL OR ECONOMIZER CYCLE IS REQUIRED ON ALL PHASE II NON ODOR PRODUCING TENANTS. IF AN ECONOMIZER CYCLE IS INCORPORATED, THE HVAC SYSTEM SHALL INCORPORATE A GRAVITY OR INTEGRAL POWERED RELIEF IN THE ROOFTOP UNIT. PHASE II, G2 AND FOOD COURT - SUPPORT RTUs ON FULL PERIMETER CURB AS SUPPLIED BY THE UNIT MANUFACTURER ONLY IN AREAS STRUCTURALLY AND AESTHETICALLY APPROVED BY LANDLORD DETAILS. C -5 X 6.7 LBS /FT STRUCTURAL STEEL CHANNEL SUPPORTS TO SPAN JOISTS UNDER RTU CURB. ALL TENANT ROOF EQUIPMENT SHALL BE LOCATED AT A MINIMUM OF FIFTEEN 515> FEET FROM ANY MALL EQUIPMENT, AND FROM ANY OTHER TENANT'S ROOF EQUIPMENT. NOTIFY LANDLORD'S ENGINEER OF ANY CONFLICTS. OBTAIN LANDLORD FIELD REPRESENTATIVE'S WRITTEN APPROVAL BEFORE CUTTING ROOF. GOOSENECKS SHALL NOT BE INSTALLED UNLESS SPECIFICALLY APPROVED BY LANDLORD. TEMPORARY WORK PLATFORM (MIN. 4' -0' WIDE) IS REQUIRED CONSISTING OF PLYWOOD COMPLETELY SURROUNDING THE ROOFTOP UNIT($) AND OTHER EQUIPMENT OR DUCTS THROUGH THE ROOF. THE ENTIRE WORKING AREA SHALL REMAIN ON ROOF DARING THE ENTIRE PERIOD OF INSTALLATION AND SHALL BE REMOVED FROM THE ROOF AND THE SHOPPING CENTER SITE UPON COMPLETION OF THE INSTALLATION BY CONTRACTOR. ALL ROOF MOUNTED FANS, TOILET EXHAUSTER$, AND MISCELLANEOUS EQUIPMENT SHALL BE OF ALUMINUM CONSTRUCTION, WITH FABRICATED ROOF CURBS AS DETAILED ON LANDLORD'S TYPICAL TENANT'S MECHANICAL DETAILS AND SPECIFICATIONS DRAWINGS. ROUTE ELECTRIC POWER AND CONTROL WIRING THROUGH A SEPARATE ROOF PENETRATION FOR EACH OF THE CONDUITS. FLASH PENETRATION PER LANDLORD DETAILS. DO NOT ROUTE POWER CONDUIT THROUGH ROOF CURB WALL. DO NOT DRILL HOLES IN CONDENSATE PAIN OR COMPRESSOR /CONDENSER SECTION FLOOR. J. ALL TENANT ROOF MOUNTED EQUIPMENT SHALL BE IDENTIFIED WITH A LANDLORD SUPPLIED LABEL. THE TENANT SHALL CONTACT THE NALL MANAGEMENT FOR THE NECESSARY LABEL. IF THE LANDLORD'S LABEL IS NOT AVAILABLE THE ROOF TOP EO IPMENT SHALL BE MARKED WITH THE TENANT'S NAME AND UNIT NUMBER WITH A MINIMUM OF 1 -1/2' STENCILED LETTERS. K. FRAME ALL SIDES OF ROOF PENETRATIONS, IF ONE SIDE OF PENETRATION IS GREATER THAN 12 INCHES, WITH 3' X 3' X 1/4' ANGLE TO SUPPORT THE METAL DECK ANGLES SHALL BE CLAMPED OR WELDED TO THE STRUCTURAL STEEL JOISTS, BEAMS, OR GIRDERS AND SHALL BE INSTALLED TIGHT TO THE BOTTOM OF THE ROOF DECK. INSTALLATION SHALL BE AS APPROVED BY THE LANDLORD. DO NOT DRILL JOISTS' L ' ROOF MOUNTED EQUIPMENT PROJECTIONS NONE OF TENANT'S HVAC EQUIPMENT OR ANY OTHER TENANT ROOF MOUNTED CONSTRUCTION SHALL BE VISIBLE ABOVE THE EXTERIOR WALL PARAPET, UNLESS OTHERWISE PERMUTED BY LANDLORD. IF PERMITTED, TENANT SHALL, AT TENANT'S EXPENSE, PAINT ALL SUCH HVAC EQUIPMENT OR ROOF MOUNTED CONSTRUCTION AND /OR PROVIDE SCREENING FOR SAME AS MAY BE REQUIRED BY LANDLORD. DIFFUSERS, GRILLES, AND REGISTERS SMALL BE STEEL OR ALUMINUM AS MANUFACTURED BY TITUS, BARBER- COLMAN, CARNES, OR OTHER APPROVED WITH OPPOSED BLADE DAMPERS. RETURN AIR BETWEEN STOCK AND SALES AREA SMALL NOT RELY UPON ANY ACCESS WAY (DOORWAYS, WINDOW OPENINGS, ETC.) BETWEEN STOCK AND SALES AREAS, AIR BALANCE ALL EQUIPMENT, INCLUDING ROOFTOP UNITS, DIFFUSERS, REGISTERS, AND GRILLES TO THE AIR QUANTITIES INDICATED ON THE PLANS OR ON THE AND TO WITHIN 10X OF VALUES. FLEXIBLE CONNECTORS WHICH ARE CODE APPROVED ARE REQUIRED ON ALL DUCTWORK CONNECTIONS TO AIR MOVING EQUIPMENT INCLUDING ROOFTOP AIR HANDLING UNITCS), AND FANCS). FIRE DAMPERS ARE REQUIRED TO BE INSTALLED IN ANY OPENING IN ANY PARTITION WHERE THE OPENING OCCURS BELOW THE LEVEL OF THE SPRINKLER PROTECTION ON ONE SIDE OF THE PARTITION AND ABOVE THE SPRINKLER PROTECTION ON THE OTHER SIDE OF THE PARTITION, AND PENETRATIONS OF FIRE RATED CONSTRUCTION PER CODE. FIRE DAMPERS SHALL BE U.L. LISTED AND INSTALLED PER MANUFACTURERS REQUIREMENTS. FIRE DAMPER($) SHALL BE RUSKIN, AIR BALANCE, OR OTHER LANDLORD APPROVED. ALL NON - HOODED DUCTWORK, FITTINGS, HANGERS, FABRICATIONS, INSTALLATIONS, MATERIALS AND METHODS SHALL BE GALVANIZED SHEET METAL FABRICATED AND INSTALLED IN STRICT ACCORDANCE WITH THE LATEST EDITION OF SHACNA, NFPA, ALL CODES AND AS DETAILED ON DRAWINGS. UNLESS OTHERWISE NOTED, SUPPLY, RETURN, AND EXHAUST DUCTWORK SHALL BE CONSTRUCTED IN CONFORMANCE WITH THE 1' W. G. POSITIVE /NEGATIVE PRESSURE TABLE. ALL DUCTWORK SHALL BE INSTALLED AS HIGH AS POSSIBLE. WHERE APPROVED FOR INSTALLATION BY THE LANDLORD, FIBERGLASS DUCTWORK SHALL BE I -1/2' OVENS /CORNING TYPE 900 FRK INSTALLED PER THE MANUFACTURER'S AND SMACNA'S REQUIREMENTS FOR SUPPLY AND RETURN AIR DUCTWORK. INSULATE ALL SUPPLY AIR, OUTSIDE AIR, AND COMBUSTION AIR DUCTWORK WITH 1 -I/2' THICK EXTERIOR FIBERGLASS DUCT INSULATION WITH VAPOR BARRIER PER MANUFACTURERS REQUIREMENTS AND RECOMMENDATIONS, IF CONDENSATE FORMS ON ANY MALL OR TENANT SURFACE, INSULATE AS REQUIRED TO ELIMINATE THE CONDENSATION, FLEXIBLE DUCTWORK SHALL ONLY BE PERMITTED TO BE INSTALLED FOR THE FINAL VERTICAL CONNECTION TO DIFFUSERS. THE MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE LIMITED TO 5' -0' FOR ANY ONE DIFFUSER CONNECTION FLEXIBLE DUCT MATERIAL SHALL HAVE A FLAME SPREAD LESS THAN 25 AND A SMOKE DEVELOPED RATING LESS THAN 50. SECURE BOTH ENDS WITH APPROVED PLENUM MATERIAL. V. DUCTED RETURN AIR SYSTEMS SHALL ONLY BE INSTALLED WHEN REQUIRED OR APPROVED BY LANDLORD. WHEN A DUCTED RETURN AIR SYSTEM IS REQUIRED (OR PERMITTED) BY LANDLORD, FURNISH AND INSTALL RELIEF GRILLES IN CEILING TO PREVENT FREEZING. RELIEF GRILLES SHALL BE SIZED AT 1 SQ. FT. PER 300 S0, FT. LEASABLE AREA.. DUCTED RETURN AIR SYSTEM GRILLES SHALL BE SIZED FOR A MAXIMUM OF 500 F.P. M. VELOCITY. SEAL DUCT PENETRATIONS AT DEMISING WALLS WITH MATERIAL APPROVED BY APPLICABLE CODE AUTHORITIES. TENANTS WHICH, IN THE SOLE OPINION OF THE LANDLORD, PRODUCE ODOR SHALL PROVIDE AN EXHAUST SYSTEM AND /OR OTHER SYSTEMS, WHICH WILL PREVENT SUCH ODORS FROM ENTERING THE MALL COMMON AREA OR OTHER TENANT SPACES. X TENANT'S CONTRACTOR MUST TAKE THE FOLLOWING ACTION FOR THE STATT UP OF ALL NEW HVAC UNITS. PRIOR TO OPENING THE PREMISES FOR BUSINESS CONTRACTOR SHALL PROVIDE LANDLORD VITH WRITTEN VERIFICATION FROM AN AUTHORIZED REPRESENTATIVE OF THE INSTALLED HVAC EQUIPMENT MANUFACTURER THAT THE HVAC EQUIPMENT IS INSTALLED AND OPERATING IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S REQUIREMENTS. IN THE EVENT THE LANDLORD DETERMINES TENANT'S HVAC EQUIPMENT IS NOT OPERATING IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS, LANDLORD'S FIELD REPRESENTATIVE SHALL , WITHIN FIVE (5) DAYS FROM LANDLORD'S WRITTEN NOTICE TO TENANT BR TENANT'S CONTRACTOR OF SAME, CORRECT SUCH OPERATIONAL DEFICIENCY. Y. EXHAUST FANS 1. EACH TOILET ROOM SHALL HAVE A TOILET EXHAUST FAN, CONTROLLED BY A LIGHT SWITCH, SIZED PER cam AND RATED AT MINIMUM .25'EXTERNAL STATIC PRESSURE, TOILET EXHAUST FAN SHALL BE CONNECTED TO LANDLORD'S TOILET EXHAUST DUCT. TOILET EXHAUST FANS SHALL BE CEILING MOUNTED WITH INTEGRAL GRILLES, AND BACKDRAFT DAMPER. FAN SHALL BE PENN, GREENHECK, NUTONE OR OTHER APPROVED. 2. ROOF MOUNTED GREASE EXHAUST FANS SHALL BE BELT DRIVEN, UPBLAST CENTRIFUGAL TYPE APPROVED FOR GREASE LADEN AIR, MOTORS SHALL BE INSTALLED OUT OF THE AIR STREAM, COMPLETE WITH DISCONNECT SWITCH. FANS SHALL BE SIMILAR TO 'GREENHECK • MODEL CUBE, MEETING NFPA 96 REQUIREMENTS. ALL ARE TO HAVE GREASE GUARD INSTALLED. SEE DETAIL. 3. ALL FANS REQUIRED FOR RELIEF, MAKE -UP AIR OR EXHAUST (EXCEPT TOILET ROOM) SHALL BE AN UPBLAST ROOF MOUNTED AND OF A CENTRIFUGAL TYPE VITH A BELT OR DIRECT DRIVEN ENCLOSED MOTOR OUTSIDE THE AIR STREAM. CLASS B TYPE MOTORS SHALL BE USED FOR HIGH TEMPERATURE APPLICATIONS. ALL ROOF MOUNTED FANS SHALL INCORPORATE A COUNTERBALANCED BACK DRAFT DAMPER OR A MOTOR OPERATED DAMPER INTERLOCKED WITH FAN OPERATION AND A SERVICE DISCONNECT SWITCH AT THE FAN. PHASE II, G2 AND FOODCOURT SHAD_ INSTALL A SMOKE RELIEF FAN WITH MOTORIZED DAMPER. THE FAN CAPACITY SHALL BE 1 AND ONE HALF CFM PER SQUARE FOOT OF LEASEABLE AREA AT 0,25 INCH V.C. Z. HOODED EXHAUST SYSTEMS I. HOODS DUCTWORK AND ACCESSORIES SHALL BE SIZED CONSTRUCTED AND INSTALLED PER NFPA 96 AND ALL STATE AND LOCAL CODES, AND LANDLORD'S INSURANCE UN➢ERYRITERS. HOODS SHALL DE U.L. LISTED. DUCTWORK AND HOOD MATERIAL SHALL BE WELDED 16 GAUGE STEEL OR 18 GAUGE STAINLESS STEEL OR AS OTHERWISE REQUIRED BY CODES. STAINLESS STEEL CONSTRUCTION SHALL BE USED BELOW FINISHED CEILING UNLESS OTHERWISE APPROVED BY LANDLORD REPRESENTATIVE. ALL SEAMS AND JOINTS SHALL HAVE LIQUID TIGHT CONTINUOUS EXTERNAL WELDS. DUCTS SHALL BE INSTALLED WITHOUT FORMING DRIPS AND TRAPS WHICH MIGHT COLLECT RESIDUES. SLOPE DUCT TOWARD HOOD. ALL HOOD EXHAUST DUCTS SHALL BE INSULATED WITH HIGH TEMPERATURE INSULATION. THE AIR VELOCITY THROUGH ANY DUCT SHALL NOT BE LESS THAN 1,500 FEET PER MINUTE NOR GREATER THAN 2200 FEET PER MINUTE. ACCESS DOORS SHALL BE GASKETED AND PROVIDED FOR INSPECTION AND CLEANING AND SHALL BE INSTALLED AT EACH CHANGE OF DIRECTION. GREASE LADEN AIR SHALL BE DISCHARGED VERTICALLY ABOVE ROOF AT CODE REQUIRED HEIGHT. TENANT'S CONTRACTOR SHALL FURNISH AND INSTALL A 'GREASE GUARD' SYSTEM FOR ALL GREASE EXHAUST FANS. 'GREASE GUARD' SHALL BE AS MANUFACTURED BY 'GREASE GUARD' 11- 800- 284 -8273) 9. MAINTAIN MINIMUM CLEARANCES BETWEEN DUCT AND OTHER STRUCTURES AS REQUIRED BY CODE. 10. INSULATE AND /OR ENCASE DUCT ABOVE CEILINGS. INSTALL AS REQUIRED BY CODE AND PROVIDE CLEARANCES FROM COMBUSTIBLES AS REQUIRED BY CODE. AA. FLUES SHALL BE METALBESTOS TYPE B 0R, IF MORE STRINGENT, AS REQUIRED BY CODE. INSTALL IN A t HOUR FIRE RATED SHAFT, NON COMBUSTIBLE CONSTRUCTION, VITH CODE REQUIRED CLEARANCES AND INSULATED WITH FIRE RATED INSULATION, UP THROUGH ROOF, NO FIRE DAMPER SHALL BE INSTALLED IN HOOD EXHAUST, r AB. FIRE DETECTION AND SMOKE CONTROL SYSTEM L 4. THE HVAC SYSTEM SHALL INCORPORATE AN INTEGRATED SMOKE CONTROL SYSTEM AS FOLLOWS a, FURNISH AND INSTALL, IN THE SUPPLY DUCT SECTION OF THE ROOFTOP UNIT OR AIR HANDLER, U.L. LISTED IONIZATION DUCT TYPE SMOKE DETECTORS. LOCATE SMOKE DETECTORS IN AN ACCESSIBLE LOCATION, COMPLETE WITH DISCONNECT SWITCH FOR SERVICING AND RESETTING OF THE SMOKE DETECTOR WITH INDICATOR LIGHTS, PHASE I - a. 3. PHASE II - a. SMOKE DETECTOR, UPON ACTIVATION, SHALL SHUT DOWN THE HVAC SYSTEM AND NOTIFY AN APPROVED CENTRAL STATION MONITORING COMPANY. CONSULT CITY OF TUKWILA FOR A LIST OF ILL LISTED AND APPROVED CENTRAL STATION MONITORS. TENANT SHALL INSTALL AN ADDITIONAL SMOKE DETECTOR AT THE STORE FRONT AND ADDITIONAL SMOKE DETECTORS FOR EACH 30' OF OPEN STORE FRONT. b. THE SMOKE DETECTOR, UPON ACTIVATION, SHALL SHUTDOWN THE HVAC SYSTEM, NOTIFY LANDLORD'S FIRE DETECTION AND SMOKE CONTROL SYSYTEM AND ACTIVATE A SEPARATE ROOF MOUNTED SMOKE RELIEF FAN FURNISHED WITH A MOTORIZED DAMPER AND INSTALLED ON A FABRICATED CURB PER DETAIL. THE SYSTEM SHALL ACTIVATE AN AUDIBLE /VISUAL ALARM AT THE FRONT OF THE STORE UPON ACTIVATION. MINIMUM CFM CAPACITY OF ROOF MOUNTED SMOKE RELIEF FAN SHALL BE ONE AND ONE HALF CFM PER SQUARE FOOT OF GROSS LEASABLE AREA AT 0.25 INCH WATER COLUMN STATIC PRESSURE. PROVIDE ALL ADDITIONAL CONTROLS REQUIRED TO PERMIT THE SEQUENCE DESCRIBED ABOVE, INCLUDING CLOSING OF THE OUTDOOR AIR DAMPER IN THE HVAC UNIT. FOOD COURT AND G2 a. THE SMOKE DETECTOR SHALL, UPON ACTIVATION, SHUT DOWN THE ATED HVAC AT T SYSEE FM, RONT D SOUND T AN HE STORE AUDIO /VISUAL ALARM HORN LOC b. AS PHASE f I, ITEMS b, c and d AND AS PHASE I. 5. PROVIDE ALL ADDITIONAL CONTROLS REQUIRED TO PERMIT THE SEQUENCE DESCRIBED ABOVE, AC. TEMPERATURE CONTROLS, VIRING AND MISCELLANEOUS REQUIREMENTS 1. ALL CONTROLS SHALL BE A PNEUMATIC CONNECT TO LANDLORD'S CENTRAL PNEUMATIC AIR SYSTEM, AS REQUIRED. 2. ALL OTHER CONTROLS SHALL BE A MAXIMUM OF 24 VOLTS. ALL CONTROL WIRING SHALL BE INSTALLED IN STRICT ACCORDANCE VITH NATIONAL ELECTRICAL CODE. 3. ALL EXHAUST FANS (EXCEPT TOILET EXHAUST FAN) SHALL INCORPORATE STARTERS. 4. ALL EXISTING AND NEW WIRING IN PLENUM AREAS SHALL BE MODIFIED AND /OR INSTALLED IN CONDUIT OR BE CABLE LISTED FOR USE IN PLENUM AREAS. FIELD VERIFY ALL EXISTING WIRING TD DETERMINE THE EXTENT OF THE REQUIRED MODIFICATION. T. CONTROL VIRING FOR HVAC CONTROL SHALL BE MULTICOLORED CABLE. (8) - 16 AWG WITH 600V JACKET INSULATION 6. THERMOSTATS FOR TEMPERATURE CONTROL SHALL BE OF THE PNEUMATIC TYPE, REVERSE ACTING, OR OTHER LANDLORD APPROVED. MODIFY INSTALLATION OF ALL EXISTING CONTROLS AS REQUIRED BY LANDLORD FOR PROPER OPERATION O' THE HVAC SYSTEMS. 7. CONTRACTOR TO FURNISH AS BUILT' DRAWINGS OF THE TEMPERATURE CONTROL SYSTEM INCLUDING ALL HVAC EQUIPMENT CONTROL DIAGRAMS AS SUPPLIED BY THE EQUIPMENT MANUFACTURER AND ALL FIELD INSTALLED WIRING AND CONTROLS. AD, TENANT SHALL INSTALL ROD' TREAD PADS AROUND ALL ROOF MOUNTED EQUIPMENT APPRO TREAD PADS. AND TD VED LANDLORD'S MAIN TRAFFIC AISLE. CONSULT LANDLORD ROOF FOR AE. IT C EQUIPMENT, DUCTS, ETC, SHALL BE INSTALLED IN DEMISING LS. AF. PAINT ALL EXTERIOR EXPOSED METAL WITH RUST PREVENTITIVE PAINT. AG. ALL INSTALLED EQUIPMENT AND ACCESSORIES AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SEISMIC AREA ZONE MODIFY INSTALLATION DETAILS TO CONFORM AS REQUIRED. AH. ALL TENANTS SHALL PROVIDE PRDTABLE ABC FIRE EXTINGUISHERS AS REQUIRED BY THE LOCAL FIRE PREVENTION AUTHORITY HAVING JURISDICTION. EXTINGUISHERS SHALL HE LOCATED TO HAVE A MAXIMUM TRAVEL DISTANCE FROM ANY POINT IN THE TENANT SPACE TD AN EXTINGUISHER OF SEVENTY -FIVE (75) FEET. THE MINIMUM REQUIREMENT SHALL BE TWO EXTINGUISHERS WHICH ONE SHALL BE LOCATED IN THE SALES AREA AND ONE IN THE STORAGE AREA. (OR REAR OF UNIT.) AI. , NO EQUIPMENT SHALL BE INSTALLED IN THE CODE REQUIRED EXIT CORRIDOR. A CLEAR 44 INCH MINIMUM IS REQUIRED. (VERIFY WITH ARCHITECT.) AJ. ALL TENANT'S ROOFTOP HVAC EQUIPMENT SHALL BE PROVIDED WITH A MANUFACTURERS OPTIONAL CONDENSER kOIL GUARD TO PROTECT AGAINST HAIL DAMAGE, DEBRIS AND VANDALS. 4 1 2 Lz ALL INSTALLED EQUIPMENT ACCESSORIES, AND PIPING SHALL BE INSTALLED PER CODE REQUIREMENTS FOR SE SMIC Y il 1 SOUTHCENTER MECHANICAL DETAIL: AND SPECIFICATIONS Sheet 3 of 6 ® REVISED © REVISED Q2 REVISED Q REV1500 DRAWN BY: SCALE: REVISED BY: H E NAME: SCNTTM3 SEATTLE, WASHINGTON UNIT NUMBER DBA THIS SHEET & TTG•0I MUST BE INCLUDED AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS AND FOR BUILDING PERMITS w The Richard E. .Jacobs Group REVISIONS DATE: A8 NUMBER DATE TIUt►A +Rii 7/15/98 1/15/96 8/13/95 4/13/95 FLOOR SLAB SECURE BASE TO CURB WITH LAG SCREWS 12' U.C. MIN. OF 2 PER SIDE FABRICATED CURB SEE CURB DETAIL EXISTING METAL DECK RIGID CONDUIT BY ELECTRICAL MOTOR OPERATED DAMPER CORNER TO BE CUT FOR CONDUIT ROUTING DUCT INSULATION SEE SPECIFICATION SECURE BASE TO CURB WITH LAG SCREWS 12' D.C MIN. OF (2) PER SIDE FABRICATED CURB —. SEE CURB DETAIL b FISTING METAL DECK DUCT INSULATION SEE SPECIFICATION STUCTURAL SLAB PIPE PENETRATI ❑N DETAIL e NTS N.T S SLEEVE 1/2' CLEAR MIN., 3/4' CLEAR MAX. PACK WITH OAKUM & APPLY SEALANT AT REMOVE CONCRETE FLOOR TOP FOR GAS SEAL. FLUSH WITH FLOOR.r FOR PIPE PENETRATION ONLY. 1/2" WIDE x 3 /4'DEEP RECESS A DO NOT CUT REBAR rSERIM. OF CONC. PATCH. FILL WIT H REPLACE CONCRETE SEALANT FOR GAS SEAL. ECHANICALLY ROUGHENED JOINT —PIPE FORM JNDERSIDE OF SLAB CHANGER TUNNEL UNDER EXISTING SLAB FOR PIPING • NOTE SEALANT TO BE MIN. OF 1/2' THICKNESS OF BFC B. ASEAL NO. 169 BFC DIVISION OF ESSEX CHEMICAL CORPORATION OR APPROVED EQUIVALENT OF MINNESOTA MINING AND MANUFACTURING CO., DR BENJAMIN FOSTER. NOTE: ALL DUCTWORK BELOW SLAB SHALL BE CONSIDERED CONFINED SPACE. NOTES 1, H.V.A.C. CONTRACTOR TO COORDINATE INSTALLATON W /LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING & COUNTERFLASHING INSTALLATION. ❑.A. INTAKE GRAVITY RELIEF DETAIL N.T.S. TT - 12 =Q /14L!!, ,---INSECT SCREEN RESILIENT GASKET SEAL - INTAKE BASE EXISTING INSULATION SECURE CURB TO DECK W/ SCREWS 12' O.C. MIN. OF 2 PER SIDE. 3'x3`x1; 4' ANGL FRAMING (4) SIDES SEE CURB DETAIL CI GREENHECK CRS- SERIES OR EQUAL RESILIENT GASKET SEAL EXHAUSTER BASE EXISTING INSULATION SECURE CURB TO DECK W/ SCREWS 12' O.C. MIN. OF 12) PER SIDE. MOTOR ZED DAMPER NOTES AS REQUIRED 1 H,V.A.C, CONTRACTOR TO COORDINATE INSTALLATON W /LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING & CDUNTERFLASHING INSTALLATION. TT -II EXISTING ROOFING MEMBRANE /ROOF GREASE COLLECTION DEVICE IS REQUIRED. INSTALL PER MANUFACTURER'S REQUIREMENTS. TENANT MUST EMPLOY GREASE GUARD, TO INSTALL CALL 1- 800- 284 - 8273 FOR INSTALLATION SECURE BASE TO CURB WITH LAG SCREWS 12' O.C. MIN. OF 2 PER SIDE ONE PIECE WELDED ALUMINUM FAN SUB -BASE CONTINUOUS PIANO TYPE PIANO HINGE FABRICATED CURB SEE CURB DETAIL EXISTING ROOF DECK RIGID CONDUIT BY ELECTRICAL MOTOR OPERATED DAMPER CORNER TO BE CUT FOR CONDUIT ROUTING GAS LINE — ON ROOF GAS LINE SUPPORT SFF DETAIL O N.T.S. ` m 11:: II 11 II I dnnuml m ng. uu�i�,�w70u� 11 GAS VALVE FOR PIPE AND /OR CONDUIT FLASHING THRU ROOF SFE DFTALL Og 4" DIRT LEG 3" MIN. ABOVE ROOF 3 "x3 ° x1/4" ANGLE EXISTING ROOF ANGLE IRON COPED EACH END TO FIT OVER JOIST CLAMP OR WELD ANGLE TO JOIST. STEEL WASHER OLEOS HANGERS - PIPES 1 -1/4" & SMALLER B' -0" MAX. O.C. PIPES 1 -1/2" & LARGER 10' -0" MAX. O.C. GAS LINE ALUMINUM ROOF UPBLAST FAN RESILIENT GASKET VENTED CURB EXTENSION (AIR VENTS ON ALL(4) SIDES) RESILIENT GASKET FLASHING BY GREASE GAURD CONTRACTOR 16 GA. FABRICATED CURB -SFF DETAIL SEE DETAIL 26 FOR FRAMING. REQUIREMENTS 2' - 0" MAX. DISTANCE 1ST SUPPORT DIRT LEG MIN. 6" AT EACH CHANGE OF ELEVATION. CLEA t2' A %. DOUBLE NUTTED 3/8" ROD (MIN.) EXH AIR ICI GROUND JOINT UNION !1 INSULATION ANCHOR PIPE TO ANGLE WITH STD. U -BOLT GAS PIPE MIN. 1 -1/4" GAS PIPE THROUGH ROOF DETAIL (I) p N.T.S. LOCATE AWAY FROM BUILDING WALL &15' -0' FROM OUTSIDE AIR INTAKES EXTEND FLASHING OVER TOP OF INSULATION AND FASTEN AT 8'0.C. NON -COMB. INSULATION -CU TO FIT AS REQ'D. .r, CONDUIT r I SEE DETAIL 9 FOR CONDUIT ROOF k: air a f PENETRATION TAIL 'Mr VI EXISTING INSULATION EXISTING ROOF DECK ■ BOLTED PIPE CLAMP CONTINUOUS FASTENING STRIP AND APPROVED FASTENERS AT B LAP SEAL OFF METAL DECK FROM DUCT OPENING W/26 GA. SHEET METAL ALL SIDES NOTES 1. FOR BALLAST SYSTEMS REPLACE BALLAST AFTER WORK IS COMPLETED, 2, NEW INSULATION TO MATCH EXISTING INSULATION HEIGHT AND OF THE SAME OR GREATER THERMAL RESISTANCE VALUE. 3, ROOFING TO BE INSTALLED AND FLASHED -IN WITH MATERIALS TO MATCH EXISTING. INSTALL MATERIAL PER MANUFACTURER'S RECOMMENDATIONS. 4. HVAC CONTRACTOR TO COORDINATE INSTALLATION WITH LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING AND COUNTERFLASHING INSTALLATION. 5. USE SELF DRILLING FASTENERS FOR METAL DECK,TOGGLES FOR GYPSUM DECKS. RESTAURANT GREASE FAN AND PAN DETAIL ALUMINUM ROOF UPBLAST FAN REQUIRED FREE AREA SIZED ON 500 FT. /MIN VELOCITY Q_LIL f iJ FIJI Fal flIL RESILIENT GASKET SEAL HOLD DOWN CLIP EXISTING INSULATION 3'x35(1/4' ANGLE FRAMING 141 SIDES- SEE CURB DETAIL 26 NOTE. H CONTRACTOR TO COORDINATE INSTALLATON W /LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING & CDUNTERFLASHING INSTALLATION, N.T.S. TT - 10 yin Tr. Tn nr Bern CLIP H\ /AC RFI TFF /SMOXF RFI TFF ANC Pm, FYWANICT Com, TT -21 SECURE CURB TO DECK All SCREWS 12' O.C. MIN. OF 2 PER SIDE. NON DUCTED EXHAUST AIR SYSTEM ABOVE CEILINGS INSTALLED 2' DEEP SOLDERED LIQUIDTIGHT DRIP PANS 1/4' x 6' LG. GALVANIZED STEEL LAG BOLTS- BOLTS TO HOLD BLOCKING TOGETHER 1/4' x 2' LG. LAG BOLT FASTEN PIPE CLIP TO BLOCKING PLAN PLUMBING CONTRACTOR IS RESPONSIBLE TO PROVIDE GAS LINE SUPPORTS FOR ALL GAS LINES INCLUDING TENANTS PIPE SLEEVE AND CLIP. PVC PIPE SLEEVE SEE NOTE N3 VIBRATION ISOLATION GROMMET I' RUBBER SHEAR PAD OR SPRING- ISOLATOR FOR ROOF MTD. EQUIPMENT PATE SHEET METAL CURB CAP PATE CO. EQUIPMENT SUPPORT STYLE ES -2B 5- 1/2'45' MIN. 18 GA.- ALL WELDED FIRE TREATED WOOD BLOCKING. ALL (4) SIDES OF CURB. NOMINAL 6' WIDE x THICKNESS TO MATCH INSULATION THICKNESS. NOTCH WOOD TO LAY FLAT OVER CHANNEL. REINFORCED JOIST INDICATED ON MECHANICAL AND /OR STRUCTURAL PLANS WITH I. STUB COLUMNS 2, BLOCK OUT AREAS 3. JOISTS - MARKED WITH AN ASTERISK (.) 4. VERIFY PRESENTITIVE LOCATION WITH LANDLORD RE 1' WIDE 20 GA. GALVANIZED STEEL PIPE CLIP FOR THE PVC SLEEVE. 2) OCKS 4'x4' WOLMANIZED WOOD BL NOTES. SECTION 1. SUPPORT REQUIRED EVERY 1W - 0' O.C. AND AT CHANGES IN DIRECTION. INCREASE HEIGHT AS REQ'D FOR ROUTING ABOVE ROOF MOUNTED ACCESSORIES SUCH AS EXPANSION JOINTS. 3. PVC PIPE SLEEVE SHALL BE THE NEXT SIZE PIPE DIAMETER LARGER THAN THE OUTSIDE DIAMETER OF THE PIPE, OUTLINE OF EQUIPMEN NOTE. 4• AX. ROOF JOIST PLAN SECTION A NOTES UNITS GP TOR TI CBS TOTAL WEIGHT 5NALL BE SUPPORTS➢ MIN.(2) JOISTS. 2. SHITS GREATER THAN . ON CBS. HUT LESS THAN 2800 CBS. TOTAL VEIGHT SHALL BE SUPPORTED ON MIN.(3)JOISTS. 3. HVAC CONTRACTOR TO ALLOW ROOFER TO INSTALL COUNTERFLASHING PRIOR TO INSTALLING PATE CURB CAP. CONDENSING UNIT AND OTHER SPECIAL ROOF MOUNTED EQUIPMENT SUPPORT DETAIL NTS TT -18 1 5 /8' UNISTUT SECURED AT EACH END WITH 1/4• LAG BOLTS (P -4000 CHANNELS) SUCTION E O R HDT GAS wsuLAT LIQUID ELECTRICAL CONDUI UNISTUT PIPE CLAMPS 71111 PIPE CLAMP TO A GUIDE ONLY. INSTALL 6' LENGTH INSULATION. SLOPE AWAY FROM PIPE CHAS UNISTUT PIPE CLAMP PIP CURB SUPPORT PATE C O. N/N STYLE / 2 N HIGH IN.IB GA. W/2,4" CURB CURB TO BE MAX. HU 1 PAO ON TOP OF ROOFING EXISTING METAL DECK INSUL TE THE LIQUID LINE TO A POINT I' BEYOND ULLER- SEAL ENDS 8'0' SECURE CHASE TO METAL DECK AT /4 POINTS WITH A L 1/2 W DE 6 D SHEET NEPAL CLTF ANGLES AND FASTEN TO CHASE WITH SCREWS. SECTION - "A" CUT SLOTTED HOLES Ik COVER AND CLOSURE PIECE FOR PIPING V4• SMALLER THAN OVERALL SIZE. COMPRESS INSULATION AND FORCE INTO PLACE, CAULK PERIMETER OF PIPES. SE CLOSUR RE E TO CU PIECE RB BELOCAP. W PIPING AND BEHIND COVER. CU NOTES. PLAN TAL DECK SECTION - "B" DLT CHANNEL TO EACH JOIST CHANNEL SUPPORT ON TOP OF DECK EQUIPMENT SUPPORT CURB ROOF MTD. EQUIPMENT LAG BOLT WITH FLATWASHER SECURE CURB CAP TO CURB WITH SHEET METAL SCREWS AT 12' D.C. PATE WOOD NAILER RIGID INSULATION THICKNESS TO MATCH NAILER OVERHANG - ADHERED TC CURB - CUT INSULATION TO MEET WOOD BLOCKING EXISTING INSULATION EXISTING METAL DECK F ASTEN CURB TO CHANNEL (M 24. O.. MA% (MIN. 4 PER CURB) BOLT CHANNEL TO EACH JOIST WITH MACHINE BOLT, NUT AND WASHER. AD MIT ERB 1 JOIST. SECURE CURB TO METAL BECK AT 12'O,L.NAX.(NIN. 2 PER SIDE) IB GA LV VIDA. GALV. METAL REFRIGERANT AL. GA CURB CHASE FOR LOVER TENANTS ONLY SECTIDN -"C" CONDUIT LIQUID INSULATED COVER i NOTE ALL SEAMS TO BE SOLDERED WATER TIGHT EiAL COVER VITH [• [NSULa i[ON .AINCTION BOX FASTENED TO METAL CURB - "CLOSURE PIECE FASTEN COVER AT 1°." THRU CURB CAP RESILIENT GASKET RIGI➢ INSULATION TO MATCH THICKNESS OF WOOD NAILER. ADHERE TO CURB FABRICATED CURB. SEE CURB ➢STALL l CONTRACTOR NTERFLASHING I TO O NRTE NSTALLATION. INSTALLATION WITH LANDLORDS ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING AND CDU [! 0110I[ MI Ill' 1 IONA - I' lnlll n[[0 11[D! [f l 1 0[I1J[II ill inr TC 3. CAULKING TO BE SILICONE BASE AND WATERPROOF. REFRIGERANT PIPING SOUTHCENTER MECHANICAL DETAIL! AND SPECIFICATIONS Sheet 4 of 6 UNIT NUMBER SEATTLE, WASHINGTON DBA THIS SHEET & TTO.OI MUST BE INCLUDED AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS AND FOR BUILDING PERMITS The Richard E. Jacobs Group Q3 REVISED Q2 REVISED Q REVISED PENSIONS 7/15/98 1/15/96 7/10/95 APPLIANCE HEAT GAIN CALCULATIONS APPLIANCE NO. FUEL/ MOTORS INPUT K.W. FACTOR INPUT TUH B S ENSIBLE FACTOR SENSIBLE HEAT GAIN LATENT FACTOR LATENT HEAT GAIN Z. Z z a g a U LU w GAS .33 .17 � ° ELECTRIC 3413 .33 17 w p GAS ELECTRIC 3413 .10 14 _ z w a P In = a o °a MOTORS HP 2545 .30 - ELECTRIC 3413 .30 OTHERS TOTALS KITCHEN EXHAUST FAN MANUFACTURER MOTOR H.P. C.FM POWER V/ HZ/ 0 MODEL FAN R.P.M. ESP DRIVE BELT MOUNTING CURB APPLIANCE SCHEDULE APPLIANCE NUMBER APPLIANCE FUEL TYPE GAS /ELECT, FUEL RATING BTUH /KW HOODED UNHOODED 2"x4" FIRE TREATED WOOD NAILER. SECURE TO CURB AT 12 "O.C. (MIN. 2 PER SIDE). FABRICATED 16 GAUGE GALVANIZED SHEET --. METAL ALL Wa:.C./ CONSTRUCTION. PAINT AFTER PAINT WITH RUST RESISTANT AFTER FABRICATION. FABRICATE HGT. OF CURB SO THAT HGTABV.ROOFING SURFACE IS A MIN. 10'. FOR HOOD EXHAUST SYSTEMS SEAL OFF OPENINGS IN DECK W/ METAL PLATE SECURE CURB TO DECK WITH SCREWS AT 6" O.C. 3 "x3 "x1/4" ANGLE FRAMING ALL SIDES OF DUCT PENETRATION, WELDED OR BOLTED TOGETHER. COPE ANGLES PERPENDICULAR TO JOISTS TO ALLOW TOP LEG TO SET ON TOP CHORD OF JOIST. WELD OR CLAMP ANGLES TO JOIST. ANGLE MAY BE OMITTED ON SIDE OF DUCT OPENING WITHIN 6" "F JOIST. REINFORCED ISTS N IDIN MECHANICAL AN /OR STRUCTURA L b PLANS WITH: BLOCK OUT AREA. 2. JOIST MARKED W/ AN ASTERISK. <AP ANGLE OVER JOIST MIN. OF 2' 5 "x 6.7y F CHANNEL SGPPORT ON TOP OF DECK ' -0' O.C. MAY. SPAN TWO JOIST MIN. OUTLINE OF R.T.U. ri07ES: 1. INTERIOR DIMENSIONS TO BE DETERMINED BY SPECIFIC EQUIPMENT. SEE DETAILS. 2. EXTERIOR MIN. DIMENSIONS OF CURB FOR FLASHING AND COUNTERFLASHING SHALL BE 12"x12". 4" MFTHOD #1 (TYPICAL FRAMING FOR RTU'S UP TO 1880 LBS. TOTAL WEIGHT) RTU STRUCTURAL FRAMING PLAN N.T.S. MAIN WALKWAY BY LANDLORD BY TENANT OYEZ' ' R.T.U. CURB N.T.S. SEE NOTE {f1 SEE NOTE #2 L TREAD PAD (CONSULT LANDLORD ROOFER FOR TREAD PAD) I11' I . 2" MIN. SECTION 'A' 0 USE THIS DETAIL FOR NON - REMOVEABLE EQUIPMENT / DETAIL OF FABRICATED CURB 26 N.T.S. 17-26 FOR HOOD EXHAUST OR WHERE CODE DOES NOT PERMIT TREATED WOOD BLOCKING, OMIT WOOD BLOCKING AND UTILIZE ROOFING MATERIAL PER CODE. METAL DECK. ANGLE NOT REO'D HEN DECK O i IS WRHIN 6 OF JOIST W 3z3z1/4" DULT OPG. FRAMING ttP. 4 SIDES /OPC POWER &CONTROL WIRING THRU ft00F SFF f1FTAll O WHEN CURB PROJECTS BE JOIST MORE THAN 18 E C TO NE1R JOIST. Pi 1 I TT -BS 2 "x2" FIRE TREATED WOOD NAILER. SECURE TO CURB AT 12 "0.C.(MIN (2) PER SIDE) USE THIS DETAIL FOR REMOVEABLE EQUIPMENT - -RIGID INSULATION TO MATCH THICKNESS OF NAILER. ADHERED TO CURB. CUT INSULATION TO MEET WOOD BLOCKIN EXISTING INSULATION TO REMAIN. REPLACE ALL DAMAGED INSULATION TO MATCH EXISTING. METAL DECK EXISTING JOIST FIRE TREATED BLOCKING ALL (4) SIDES OF CURB. NOMINAL 6"WIDE x THICKNESS TO MATCH INSULATION THICKNESS. 5' x 6.7M /FT. CHANNEL SUPPORT ON TOP OF DECK 6' -0" O.C. MAX. SPAN. MINIMUM OF 3 JOISTS 1111 I W■rii MIN. lAP NGLE OVER J015T A MIN. OF 2' OUTLINE OF R.T.U. FULL PERIMTER ROOF R.T.U. E CURB ANGLE NOT REO'D WHEN DECK OPENING IS WITHIN 6" OF JOIST MINIMUM. ANGLE FRAMING FOR DUCT PENETRATIONS ttP. 4 SIDES /OPG ROOF JOISTS LAP ANGLE MIN. 2" OVER JOIST III i ANGLE FRAMING FOR DUCT PENETRATION , ETRATION _ u I 111 :: :21: Ii�Ig ■_ = _. I INN ill ITERED JOINTS WELDED AND GROUND SMOOTH ON CURB (TYP.) PLAN REINFORCED JOISTS INDICATED ON MECHANICAL AND /OR STRUCTURAL PLANS WITH: 1. BLOCK OUT AREA. 2. JOIST MARKED W/ ASTERISK. BOLT CHANNEL TO EACH JOIST (TYP) METHOD !!2 (TYPICAL FRAMING FOR BTU'S BETWEEN 1880 LBS. & 2800 LBS. TOTAL WEIGHT) RTU STRUCTURAL FRAMING PLAN N.T.S. OF NOTF4. I. FIELD VERIFY LOCATION OF RTU PRIOR TO INSTALLATION. 2. ALL SHOWN BY TENANT CO.. UNLESS OTHERWISE NOTED 3. PROVIDE INSULATION IF WOOD NOT PERMITTED BY CODE. SEE NOTE #2 STAINLESS STEEL CLAMPING RING SOLDER JOINT ROOFING MEMBRANE INSULATION 18" MIN. SQ. LEAD POWER Be CONTROL WIRING THRU ROOF SEE DFTNI O VENT PIPE TYPICAL DETAIL -- LEAD - BUR METAL DECK 4 LB. VIRGIN LEAD FLFJ(. DUCT CONN ECTION RTU STRUCTURAL FRAMING PLANS AND SECTION O N.T.S. 1T -1 FOR PLUMBING VENTS TURN LEAD FLASHING DOWN INTO VENT PIPE A MIN. OF 1" BELOW TOP OF PIPE NOTES: 1. FOR BALLAST SYSTEMS, REPLACE BALLAST AFTER WORK 15 COMPLETED. 2. 4 LB. LEAD FLASHING SHALL BE 1/4" MAX. DIAMETER LARGER THAN PIPE ALL JOINTS TO BE SOLDEREC. 3. FLANGE SHALL BE SET BY ROOFER. CONTACT L.L. FOR LIST OF APPROVED ROOFING CONTRACTORS 4. ALL ROOFWORK TO BE PERFORMED BY MALL APPROVED ROOFING CONTRACTOR 5. VENTS SHALL BE A MINIMUM OF 1V-0 FROM OUTSIDE AIR INTAKES. Vi MEI " METALBESTOS" TYPE RV FOR 8" OR SMALLER TYPE QC FOR 10" OR LARGER DOUBLE WALL. " METALBESTOS" TALL CONE TURN DOWN FLASHING FLANGE 2" ALL SIDES TO FORM CURB CAP. (SOLDER CORNERS.) RESILIENT GASKET MIN. OF 3' -0" HEIGHT SHALL BE AS REQ'D BY LOCAL CODE. LOCATE 25' -0" FROM BLDG. WALL AND 15' -0" FROM OUTSIDE AIR INTAKE. CONTACT LANDLORD. ra ' t Nom lot wftramallwalm Y �� •� DUCTWORK RIGID INSU TO MATCH THICKNESS OF NAILER ADHEREI TO CURB CUT INSUL TO MEET WOOD BLOCKING ROOFING SET CURB LEVEL WHIN UNIT MFR'S. RECOMMENDATIONS RESILIENT GASKET CONTINUOUS FIRE TREATED WOOb NNLER B'/ UNR MAivUFACTURER FULL PERIMETER ROOF TOP EQUIPMENT CURB PROVIDE STEEL SHIMS BF CURB CHANNEL O 24 N O.C. IF REO D FOR LLYELING. CONNEC TO UNIT T DUCT LINER- -+ WHERE REQ'0 3 N 3° N 1/ANGLE FRAMING N ALL SIDES O4 ° F DUCT PENETRATIO, WEILDED OR BOLTED TOGETHER. COPE ANGLES PERPENDICULAR JOISTS TO ALLOW TOP LEG TO SET ON TOP CHORD OF JOIST. WELD OR CLAMP ANGLES TO JOIST. ANGLE MAY OMITTED SIDE OF DUCT OPENING WITHIN 6' OF JOIST. MINIMUM CLEARENCE NOTES: 1. H.V.A.C. CONTRACTOR TO COORDINATE INSTALLATION Wit LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING & COUNTER FLASHING INSTALLATION. 2. CURB INTERNAL SIZES: FOR FLUES 3" THRU 5" ROUND -9 "x9 CURB. FOR FLUES 6" THRU 8 ROUND -12 "02" CURB, FOR FLUES GREATER THAN 8" ROUND CONSULT WITH THE LANDLORD. GAS FLUE THRU ROOF DETAIL 0 N.T.S. TT -4 SEE NOTE #2 STA INLESS STEEL CL AMPING RING RUBBER jj LAP SEALANT ROOFING MEMBRANE PRE - MOLDED PIPE SEAL GAS PRESSURE REGULATOR (WHERE REOUIREO) GAS COCK 5'x6.7Y /FT. HANN� BOLT CHANNEL TO O EA JOIST W MACH. BLT NUT & ASH. DO N'T DRILL A? FIRE TRFATEp WOOD BLOCKING. ALL FOUR SIDES OF CURB NOM 6" WIDE X THICKNESS. TO MATCH INSULATION THICKNESS SECUR CURB TO CHANNEL W 3 8" ROUND SlO. MACHINE LT . MIN. (4 ER UNIT. 4' -0 O.C. ( .} SECTION "A" " METALBESTOS" CAP BIRDPROOF " METALBESTOS" STORM COLLAR SET IN SEALANT ///--- --- SECURE TALL CONE TO CURB MIN. 2 PER SIDE ® 12 O.C. FABRICATED CURB SEE CURB DETAIL 26 SECURE CURB TO DECK W/ SCREWS 12" O.C. MI (2) PER SIDE SECURE FLUE ((TO)) DECK AT V4 POINTS WIDE 16 WITH MIN. OF SHEET METAL C`L(P ANGLES RIVETED TO GA. FLUE, SECURED TO DECK. FOR MODEL QC VENTS USE" METALBESTOS" SUPPORT PLATE. WATER CUT -OFF MASTIC SPLICING CEMENT GAS SERVICE (WHERE REQUIRED) INSULATION --I •• NOTE: DO NOT TRIM DECK FLANGE NOTES: 1. PRE - MOLDED PIPE SEAL CANNOT BE CUT VERTICALLY TO BE INSTALLED. 2. PRE- MOLDED PIPE SEAL MUST HAVE INTACT RIB AT TOP EDGE REGARDLESS OF PIPE DIAMETER. 3. WHEN PREFABRICATED PIPE SEAL CANNOT BE INSTALLED, USE FIELD FABRICATED PIPE SEAL. SEE ALTERNATE PIPE FLASHING DETAIL. 4. FOR BALLAST SYSTEMS, REPLACE BALLAST AFTER WORK IS COMPLETED. 5. FLANGE SHALL BE SET BY ROOFER. CONTACT L.L. FOR LIST OF APPROVED ROOFING CONTRACTORS 6. ALL ROOFWORK TO BE PERFORMED BY MALL APPROVED ROOFING CONTRACTOR 7. VENTS SHALL BE A MINIMUM OF 10' -0 ". TYPICAL DETAIL - PREMOLDED - RUBBER ROOF N.T.S. EXISTING INSULATION EXISTING METAL DECK INSULATION METAL' DECK JOIST TO SUPPLY AIR MAIN VOLUME DAMPER 1 -1/2" THICK FIBERGLASS W/ FOIL FACING FLEXIBLE DUCT MOUNTING DETAIL 99 N.T.S. TT-B9 SECURE TO ROO DECK INTO OP OF FLANGE EXISTING ANGLE F RANF" (PROVIDE NEW 3 3 ANGLE FRAME IF NONE EX M ST BE S 1PPORTED BYN METAL OECN GALVANIZED SHEET METAL DUCT PLAN OF EXISTING ROOF DECK NEW ROOF INSULATION MLR.' METAL STRAP CLAMP `MIN. 11111t1IRAMBbNT1ftJRL /l�ltlil .witltAOeh %tAAAiH11T11 81MN 'PNC 8 I SECTION 1 - 1 (FOR OPENING LARGER THAN TNT NEW ROOF INSULATION intit RNA{ to lUWlRIR1tAAitandaAAAaAGTAMIUTA RO OF ∎■■•= 20 GA GALV. STEEL MLR.'" - THIN. SECTION 2 - 2 (FOR OPENINGS 16" & SMALLER) REPAIRS TO THE METAL DECK SYSTEM (TYPICAL) 2 PLACES INSULATED FLEXIBLE CONNECTION. (MAX. 5' -0") IN VERTICAL ONLY. SUPPLY AIR DIFFUSER. JVf iTFC' 1. NEW INSULATION TO MATCH EXISTING INSULATION HEIGHT & OF THE SAME OR GREATER THERMAL RESISTANCE VALUE. 2. ROOFING TO BE INSTALLED AND FLASHED -IN WITH MATERIALS TO MATCH EXISTING. INSTALL MATERIALS PER MANUFACTURER'S RECOMMENDATIONS. 3. IF METAL DECK FOR OPENINGS LARGER THAN 16' IS NOT AVAILABLE, CONTACT LANDLORD'S STRUCTURAL ENGINEER. JOIST NEW INSULATION FQR OPENINGS i6 &SMALLER FOR OPENINGS LARGER THAN 16" JOIST NEW METAL DECK TO MATCH XIST. PROFILE AND GAGE. EMTfTAE PRI S NEW EXISTING,WILL NESTQ WRH SOUTHCENTER SEAT., WASHINGTON MECHANICAL DETAILS AND SPECIFICATIONS Sheet 5 of 6 UNIT NUMBER THIS SHEET & TTO.01 MUST BE INCLUDED AS PART OP TENANT'S SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS AND FOR BUILDING PERMITS The Richard E. Jacobs Group Q2 REVISED REVISED REVISIONS 7/15/98 1/ DRAWN BY: SCALE: REMSED BY: FILE NAME SCN TTM 5 ORAWWG NUM DATE J08 NUMBER DATE TTRAr,., SEARS U NORDSTROM ® 5" REF CONC. SLAB ON GRADE Imo REINFORCED STRUCTURAL S LAB TYPICAL UNLESS OTHERWISE NOTED NOTE: 1. THE "SPECIAL BUILDING CONDITIONS` NOTED ON THIS DRAWING SHALL BE CONSIDERED BUILDING /CONSTRUCTION RESTRICTIONS. ALL CONDITIONS MUST BE FIELD VERIFIED BY TENANT. 2. NONE OF THE NOTED CONDITIONS MAY BE ALTERED IN ANY WAY. NO FLOOR PENETRATIONS AGE PERMITTED UNLESS REVIEWED AND APPROVED BY THE LANDLORD'S ENGINEERS AND ALL PRESIDING GOVERNMENTAL AUTHORITIES. 1=11 Ea1 � FOOD COURT L. u J . 10 o o mop iIb ■, Erg MOO i -wI ■ 3. THERE ARE LOCATIONS BELOW THE FLOOR SLAB AT WHICH SPECIAL EQUIPMENT HAS BEEN LOCATED. FIELD VERIFICATION OF THESE IS THE TENANTS RESPONSIBILITY. ., 4. UNDER FLOOR AREAS ARE HAZARDOUS LOCATIONS DUE TO CONFINED SPACES AND FLAMABLE GAS FORMATION. A 5. DO NOT CHANNEL FLOORS. STRUCTURAL DAMAGE WILL RESULT. FOOD COURT tri MERVYN'S JCPENNEY JCPENNEY DRAWN BY: SCALE: RENSEO 9Y: FILE NAME: SCNTM6 1/15/96 GALVANIZED ANIEED PIPE STRAPS A CADIUM PLATED DOLTS (TYPICAL) CONDUIT - 3"x3 "zt /4" CALVANZED STEEL ANf,LE 6' -O" O.C. 1 /2' EXPANSION SHIELD EQUIPMENT PAD SLAB CLEANOUT INSTALLED BY LANDLORD EXISTING --- BY LANDLORD - CAST IRON SPOOL PIECE NO HUB CAST IRON PIPING ABOVE 9 - 0" COUPLING SEE NOTE 5 FOR ALTERNATE SANITARY • 1 I I CONNECTION /I1 lll 111 11110 7T -1'1-1)--/L- 411° - INVERT ELEVATION AS SHOWN ON LANDLORD'S DRAWINGS NOTE: 1. TENANT SHALL CONNECT SANITARY DRAIN TO CONNECTIONS PROVIDED BY LANDLORD. 2. TENANT SHALL NOT MODIFY LANDLORDS DRAIN OF MAKE CONNECTIONS TO SANITARY MAIN. 3. ABOVE AND UNDERGROUND COUPLINGS SHALL BE "CLAMP -ALL" DRAIN COUPLING MODEL- H I -TORQ 125. 4. NO PVC PIPING SHALL BE ALLOWED IN RETURN AIR PLENUMS. 5. IF EXISTING LANDLORD PROVIDED UPPER SANITARY TENANT CONNECTION CANNOT BE USED, CONTRACTOR SHALL USE LOWER ALTERNATE SANITARY CONNECTION. 6. TENANT MAY USE CAST IRON BELL AND SPIGOT WITH APPROVED COMPRESSION FITTINGS BELOW GROUND. TENANT SANITARY PIPING DETAIL N.T.S. O PIPE SUPPORT DETAIL NTS TT -135 1 a CAS IRON 'NO HUB' PIPING SrALL BE USED BELOW UPPER LEVEL FLOOR SLAB TO SERVE UPPER LEVEL TENANTS. Hs -il (SEE NOTE 3) PVC TO A MAXIMUM OF 9' - 0" ABOVE FIN. FLR. PVC /ABS STAMPED ASTM # D2665 -78 COUPLING (SEE NOTE 6) (SEE NOTE 3) GALVANIZED NUTS ROOF 1" RUBBER SHEAR PAD OR SPRING ISOLATOR FOR ROOF MOUNTED EQUIPMENT LANDLORD PROVIDED CONCRETE EQUIP. PAD ROOF MOUNTING EQUIPMENT LAG BOLT WITH FIAT WASHER - IA'n EXPANSION BOLT ROOF MOUNTED EQUIPMENT SUPPORT DETAIL 136 NTS TT -135 SEARS 6M1:01U'5 Q.P. JUR THE BON MERVYN'S 3L REVISED 2Q REVISED REVISED DRAM. NIXBFP.: SOUTHCENTER SEATTLE, WASHINGTON MECHANICAL DETAILS AND SPECIFICATIONS Sheet 6 of 6 UNIT NUMBER DBA THIS SHEET & TTO.O1 MUST BE INCLUDED AS PART OF TENANT'S SUBMITTAL TO THE LANDLORD, BIDDING CONTRACTORS AND FOR BUILDING PERMITS The Richard E. Jacobs Group RENSIONS DATE: JOB NUNBER TE T N 6/26/98 5/7/96