Loading...
HomeMy WebLinkAboutPermit D01-197 - STERLING REALTY ORGANIZATION - REPAIRDO1-197 Sterling Realty Org. 15820 Tukwila Intern'lBl • City of Tukwila Community Development I Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 222304 -9001 Permit No: DO1 -197 Address: 15820 TUKWILA 'INTERNATIONAL BL Status: ISSUED Suite No: Issued: 08/16/2001 Location: Expires: 02/12/2002 Category: ARET Type: DEVPERM Zoning: Const Type: Occupancy: THEATER Gas /Elec.: UBC: 1997 Units: 000 Fire Protection: SPRINKLERS Setbacks: North: .0 South: .0 East: .0 West: .0 Water: 125 Sewer: VAL VUE Wetlands: Slopes: N Streams: OCCUPANT STERLING REALTY ORGANIZATION Phone: 15820 TUKWILA INT'L BL, TUKWILA WA 98188 OWNER PLITT THEATRES /CINEPLEX OD C/O STERLING RECREATION, PO BOX 91723, BELLEVUE WA 98009 CONTACT :JASON HORNING Phone: 425- 455 -8169 600 106 AV NE, BELLEVUE WA 98004 *k ** * * ** * ***** * ** ** * * * * * **k * *k4c*** *•k** **** kk** k* kk* **k * *k•kk * * **** *k*k * *** *** ** *k* Permit Description: REPLACE TWO SECTIONS OF TWO GLULAM BEAMS DAMAGED BY DRY ROT. REPAIR 6 ADDITONAL BEAMS W /EPDXY. ****• k* k*********k k************* k** k************ k******* k*• k k **•'k **** *•k * * * * *k *•k * ** Construction Valuation t 140,000.00 PUBLIC WORKS PERMITS:. *(Water Meter Permits Listed Separate) Eng. Appr: Curb.Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: . Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time End Time Sanitary Side Sewer: N No: Sewer ,Main Extension: N Private: Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N *' k********* k********* ** ** * * **k * *k * * * * ** * **k *k***** k• kk* k* k *•k ****** * ** * * *k * * * * * *•kk TOTAL DEVELOPMENT PERMIT FEES: $ 2,013.79 * * * * * * * * ** ***' k***** kk******* k* k******** k******: ic* k****** k * *•k * *•k * *k * * * * * * *k * * * *k * ** Contractor License No: Permit Center Authorized Signature: -4/d0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. Signature: Print Name: a.C.0 t Y ✓'i t -1 (206) 431 -3670 Public: N Date: Date: - - ? 14 b L This permit shall become null and if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. u[:c, r u:i'.ia;id....�.. SiSG e +:'St1. i�•.:iGr.v'a:41'�� CITY OF TUKWILA Address: 15820 TUKWILA INTERNATIONAL. BL Suite: eflant Type DEVPERM Parcel #: 222304. -9001 Permit No: 001-197 Status: ISSUED Applied: 06/29/2.001 Issued: 08/16/2001 iC ** k**• k***' k********** kk*• k*** k****•k• k• k•***: k**• k** k• k* k* * * ***k*kk* * ** **k *•k•k•k•k *k•k Permit Conditions: 1, No changes will be made to the ' plans unxless approved by the :Engineer and the Tukwila Building D1 vision. When special inspection is 'required 'either the owner, architect or engineer sha11''n'otify the Tukwila Building Division of appointment.- of the inspection agencies prior to the first bui iding inspection. Copies of, all special inspection reports' Shall be submitted to the Building Division in a timely manner. Reports shall ; .contain 'address:' project name,,:;ipermit number and type of inspection being Performed. . ?, The special ' i spector shall submit a final signet{ report ,stating .whether the work requiring special inspection was, to the :bestof `the, inspector's know,ledge, in conformance with :: appro ved , . pians and specif i cations and the a p p l i c a b l e ' . :, workmanship provisions of, the UBC 11 construct>ion to done in conformance with:. .: lens` andyequirements of the Uniform Building Code ",(1997.; iition) as amended, Uniform; Mechanical Code (1'997 Edition) , nd Washington"State Energy'Code (1 9)7 Edi,tion) al i d i tlii of remit': The issuance—of a permit or approval . o plans, s and com utat ions' l not be con—,.' str.ued for be .a perml t for or an approval of , any any yi o l at i on of any of`;,- the- ,provi s i ons of the "code.,: or of any other ordinance of the jurisdiction. No ;permit presuming to give ,authority to: violate or cancel ther of this ; code .. shall 4 be, vai _i.d . J.- Electrical permi ts .sha l``l;. be obtained a through'sthe' Washington State Divisionof.'Labor and Industries ,and electrical work: will : be -i nspected by that agency ,(248:-'6630). All permits, ins,pection,'records,..and approved plans shall 'available at the .,,job site prior to the '`start of any con- struction, These;.documentsx,are to be maintained and avai able until final inspection approval is granted. All structural welding still be done by. W.A.B.O. certified welders and special inspected. (UBC - Sec. 306(a)5) ***FIRE DEPARTMENT CONDITIONS: ** - . The attached set of plans have been reviewed' by The Fire Prevention Bureau and are acceptable with the following concerns: 1 The : total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A,, 10B:C) dry chemical type. Travel distance to any •Fire extinguisher must be 75' or less. (NFPA 10, 3-1.1) 12. Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets i:.ti *vi::Lav gs: .■ :i;rrS1�n;4;� Fire extinguishers, require month l y and yearly inspections They must have a tag or -label securely attached that indicates the month year that ;the ;inspection was Performed and shall identify the. company. ,or.'.person Performing the service. (NFPA 10, 43, 4 -4 and 4 -4.3) 'Every six years,; :dr y chemical and 'hai'on type, fire 'ext inguisher s sf al l be; and subjected to the applicable r ech'arge .procedu res.:. (NFPA 1 0 , 4 -4. 0 ". :; If the required monthly and yearly `inspections of the fire,- extinguisher('s) are not accomplished or the inspection tag is not complete, ::;a reputable fire extinguisher service S:r company will be 'requ red:.to'.candtct: these required surveys. (NFPA 10, '4 -3 ,` 4-4). aintein' fires extinguisher coverage throughout. No po inti . i n an unspri nk i erect building may be more than 200 feet fr of ' an exit, 'measured along the ° ,path ,of travel. (UBC )004.2.5, No point i "n a. sprinklered building may be more than 250'.. feet from can exit, .measured ,along the. -path o f travel. " "(UBC 1004 2, 5:' : 2 Exit doors,;,shaW:sw i rig in the direction ot..' exit travel when serving a•ny,•.hazardous area or when',= serving an occupant load, of 50 or more.' (UBC ' ::1003.3.1.5 ) Exit doors ,steal l " be openable from the' inside without the use of a key any knowledge or effort.' Exit doors .shall riot be locked, chained, bo ;l,ted, barred, ° latched or otherwise.`�render�e "d, unusable. All l' unusable. devices :. shall be of an approved., type. (UFC '` 1201.3 ) • Dead bolts are not allowed -.'on auxiliary exit doors;: unless the dead bolt is automat i ea l ly retracted : when the 'door ;handle is . engaged Froiir, ns i de the tenant ; space. (•UFC. 1207.3) When , two or more exits from a ,,story are required, ' e x i t signs shall be installed at ,the required •exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2) 23 • When two or more exits from a story are required and when two or more exits from a room or an area are required, exit signs shall be illuminated. (UBC 1003.2.8.4) 24 Internally illuminated exit signs shall have both bulbs working .a at all times. (UBC 1003.2.8.4) .'� Exits shall be . illuminated any time the b u i l d i n g is occupied with light having, an intensity of not less than 1 foot candle at floor level. Fixtures required for exit illumination sha l 1 be supplied from separate sources of or wall recesses. Yhe, hanger or bracket shall be securely and properly anchored ( ) the mounting surface in nordance with the manufacturer'- instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. . Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit, (NFPA 10, 106.3) (UFC, Standard 10 -1) ::`Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) power for Group 1 Division 1.1 and 1.2 occupancies and For all other occupancies (re the exiting system se("; an occupant load of 100 6--"more. (UBC 1003.2.9, 10(n-7.-e.9.2) 6, The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of it's failure, illumination shall be automatically provided from an emergency system for Group I, Divisions 1.1. and 1.2 occupancies and for all other Occupancies where the means of egress system serves an occupant load of 100 or more. Such emergency systems shall be installed in accordance with the electrical code. (UBC 1003.9.2) 27, All exit signs shall be illuminated at all times. To ,ensure continued illumination for a duration of not less than 1 1/2 hours in case of priMary power loss, the exit signs shall also be connected to an emergency electrical system provided from storage batteries, unit equipment or an on site generator set, and the system shall be installed ,In accordance with the electrical code., (UBC 1003.2.8.5) . Maintian sprinkler coverage per N.F.P.A. 13. t Addition/relocation of walls, closets or partitions may ,13-4-5.5.3:1) extended to all areas where All new sprinkler systems and all modifications to existing, and under overhangs greeter than - four feet wide. (NFPA *' , Approval: the W.S.R.B., Factory Mutual, 'Industrial Risk . required, tncjuding all enclosed areas, below obstructions systems TnVolving More than SO heads shall have the written New sprinkler systems and all modifications to sprinkler approval'iof drawings prior to installation or modification.' sPrinkler,systems.shall have fire department review and . , - , r k ' „ require relocating and/or adding sprinkler heads. . Sprinkler protection shall be Insurers Kemper or any other representative designated ,, and/or recorgnized,by the City of Tukwila, prior to submittal to the .Tukwila Fire Prevention Bureau. No sprinkler shall commence without approved drawings. (City Ordinance #1901) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwildfire'Prevention Bureau must be , stamped with the iatelevel of 'competency seal. (WA'c 2 . appropr automatic detector coverage ' l tiC per N.F.P.A. 72. Addition/relocation of w 'closets or partitions may require relocatin§:andlor adding automatic 'fire detectors,.' 33. ,Maintain square foots-coverage of detectors Per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72, 5-1.4.2) 34. All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 36. An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be'provided directly in front of the panel. (NEC 110-16(a), NEC 110-16(c)) 37. Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 112) 38, Required fire resistive -- -construction, including oc1::dpancy . separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof cgyerings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) ,The " maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8-[B of the Uniform Building Code. (UBC 804,1) Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the. street. Numbers shall contrast with their background. (UFC 901.4.4) In order to provide.you with the fastest police and fire, protection " under emergency conditions, { :please post your suite, room or apartment number i h' a conspicuous place nea `the ". main entry door. (UFC 901.4-4). 'Fire Department: l ock, boxes shall be provided for access to all fire `alarnrpanelst and sprinkler risers. The ppropriate. key(s) for access shall be placed in the Lakbox '.orderti' forms must be ",'obtained from the Tukwila Firer' Dep tment. k(City Ordina #1900) . Contact th,e' Tukwi la F i re;.Prevent ion Bureau to witness ail required Anspections and tests., (UFC 10.503) (City Ordinance #1900 and; #1901) This.'revQlw limited : to speculative tenant space :on1y special : f'i're permits may be necessary dependinq' on detailed descripei_on of intended use:' Any overl'ooked. hazardous condition and/or violation of the . adopted Fire s'or B u i l d i n g Codes does not '`i mp approval, "of such conOt i on., or v i o l a t i o n . ' The plans, were reviewed by _510_. 1f you have any uestions, �please,;.cal1 the Tukwila Fire Preventi on. Bureau (206)574467 herebY cert i f 4ha t `1 have read these condition s ari'd will comp l:y with them :as outlined. II, provisions of. law and : ordinances... gover n,ing . tt i`s .work wi,11 be 4 :coinpl i,.e`d ;vi tti``, whether speci.f'ied herein or. n,o't. The-, granting of this :p ;ermitk di ;f not presume tb`' give : ; authority: : t violate or cancel the provision's. of any, other work or o loc.al laws regulating construction le performance of' work Print.. Name S 1 gnature: aye: .4.114:50 i�ii4c;t Project Name /Tenant: St- Prlinq Realty •rg ani7ation Co, — L &C Bowl Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ ® School /College /University Other bowling alle _ ____ Value of Construction: 140,000 Building Square Feet: 29 , 500 existing No. of Stories: 1 Area of construction (sq ft): Si t %/6 1 ess (tn Iude suite number) City State /Zip: ��5� U Tukwila Tnternation Blvd. If yes, extent of change: (Attach aclditional sheet if necessary) Tax Parcel Number: 222 304 1 - Property Owner: Sterling Realty Organization Co. Will there be storage of flammable /combustible hazardous material in the building? ❑ yes II no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Phone: 425 Pp Street Address: City State /Zip: 600 1n6th AUP NE #200 RP11e17 uQ Wn 9 8004 Fax 11: 425 455 - 8165 Contractor: Chinn t^onstruction Kevin Chinn Phone: 425 R98 - 1688 Street Address: City State /Zip: 9 1 1 • ,. Redmo . ,: c:, Fax 11: • s•s .' Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: CT Engineering Chuck Di ns;morP Phone: Street Address: City State /Zip: 180 Nickerson St_ #302 geattl W2 Wing Fa °#: — 2 8 5 i§12 20 ti-285 -0618 Contact Person: Jason Horning SRO Phone: 425 455 8169 Street Address: City State /Zip: 600 106th Ave. NR #2on Bplwuo_ WA 9Rnn4 Fax 11: a - 455 8165 Description of work to be done (please be specific): Replace two sections of two glu- lam beams damaged by dry rot. Repair 6 additional beams w /expoxy Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office ❑ ® School /College /University Other bowling alle _ ____ — Proposed use: ❑ Retail ❑ Restaurant ❑ Multi - family ❑ Warehouse ❑ HospitaI ❑ Church ❑ Manufacturing ❑ Motel /Hotel El Office ❑ School /College /University ❑ Other _ Building Square Feet: 29 , 500 existing No. of Stories: 1 Area of construction (sq ft): Will there be a change of use? ❑ yes I no If yes, extent of change: (Attach aclditional sheet if necessary) Will there be rack storage? ❑ yes C no Existing fire protection features: ® sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Will there be storage of flammable /combustible hazardous material in the building? ❑ yes II no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF T UKWI LA Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 (206) 431 -3670 Project Nut....er: Permit Number: /97 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not he accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE /CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Flood Control Zone ❑ Hauling ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer if: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public t ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only U Water Meter /Permanent 11 Size(s): ❑ Water Meter Temp It Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition . No application shall be extended more than once. Date application accepted: 6 a 5 -o Date application expires: /2 — .z5 — or Application taken by: (initials) PLEASE SIGN BACK OF APPLICATION FORM 11/30/011 1perMr.duc s:r ;;1c 3s�rd5iu,4 HORIZED AGENT: BUILDING OWNER OR AUTHORIZED Signature: Date: &b. p 1 ok,�e-� Print name: 71 ot.S e n \ oe. N M-' \ PhoneL� ASS g( bq Fax II� CC' is r� S" Address 6co ( 0 e ti e I F:.. 14- " City / 2l\.c. 0J A q 1 o o f rr", APPLICAtIO MUSt gt SUBMIT - ad WItH tHt ' _ LOWING: • A&L,p 1WINc S � . T , � ( .•BE STAMPED 13Y WASHINGTON STAT LICENSED ARCHITECT, STRUCTURAL ENGI E OtC1141 . ENGiNEER ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTII-I•TY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Ntetro: Non - Residential Sewer Use Certification if there is a change in the.amount:of plumbing fixtures (Form 1- 1 -13). Business Declaration required (Form 1-1 -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ El Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) G. Location and screening of outdoor storage (change of use only) 7. Limits of clearing/grading wills existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (71vIC 18.45.040), of those, identify by size and species which are to be removed and saved = F- 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use ~ W only) 4 11. Location and gross floor area of existing structure with dimensions and setback -I U 1 2. Lowest finished floor elevation (if in flood control zone) U O 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H -9). CD w W ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled co u- 1:1 w � ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of w any hazardous materials; ditnensions of proposed tenant space. c ❑ ❑ Vicinity Map showing location of site u_ • O W El El Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack Z layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of t— O rack. Structural calculations are required for rack storage eight feet and over. W ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished U 0 ❑ 171 O � Construction details 0 1- W w ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water F = - U supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed p sprinkler system design criteria as identified by the Fire Department. LLj Z Uco — _ O ~ ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to subrnitting for building permit application. The Department of Public Health is located at 999 Third Avenue, Suite 700, Seattle, WA or call (206) 296 -4787. (Form I-I -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Vatic! Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect /engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal 1 HEREBY CERTIFY THAT I DAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHiNGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. 0m7111i0q• Z • • �. ri I 11 111 . VOW r ail& al ` _� • Nal �4 `AktklChAk \ 'kvkk4 *otlFkkA;t** ••Ak *k * *:l:t•* *h'.t * •ltiAsk* **-A * ** * *k. ** *'Ii***t *'. Tf 'OFF 1'UKWIl �l4 ls7 : q8/16/01 14:01 TRANSMIT kh4�1** kk* th** AA.**'*****: t*** t 'is Ak***:A•:lk *A*•4**•h..*k*.t RHl� 8MI7 NUtmtier' a R0i 01:05 ' < ; Amo unt:c, 1;4222.25 08/1 6/'0 13:59 l?' wrn nl;' :Metliiad:- : :CHECI Wat ionu STERLING REALTY i t: SK5 .. — .. — .. .• .. _ rinti; Nt :) D()'1 -1 :; Type,: DEV PER 11 DEVELOPMENT PERMIT • reel : NC . X22304- •.53001 Address :.1 1820 TUKWILA 'INTERNATIONAL BL 7•atai Fees: . 01.3.79 vi� me l;. 1,222.25 Total ALL Pmts: 21 013.79 B e l .ance .00 * *`*Ah * *A fi********* h* h kk.** k :t * * * ***.***ar•h•k* #A••khk:l h **A•kAA ecourit 'Code 17escr i pt 1 or ' ` Amo1.1.nt 00/322.100 BUILDING - .NON ' RE5 x1 000/386.904 " <. STATE' RUILIY]:i�G..8URCN�IRL�E � 4.50 'Z =Z ■ � .J U+ 0 0: U NW W 2:. s J I—; 0 0 UL1 W O. LL. 2 C F— W Z F- 0 ZZ C • 1 G O L z en, r_ :W 2 V H r . W Z 0 ~ Z t.s • * ** **C •*8444,.*. * *k * *':k** Atk,:kk *,'*. *..kk * 'kh:i:4k . �:'k *4,4 *:►k:' *A. *k T•t '.14A "Ifi.'►NS i±'I • * * *rk*** *:*kk**k.4 ** f- k* **A ,ka k k *k * * t *k*kk4 :4*,4hksir.A741h4t kir v *4k 11 ;4A:k*47 :k4t R NS fI7. 14umh'er^ n ; R01008277 (rnoun.t I. 791 54 06 9r' {1i 11: 39 avme,n( :t<tetlio�de' : N ot ;t1on: .SIIU Ini 31 D. • r - - � .. . ..- W.. -_ _... • «, P 1 iki. 1: D4.twi9 1 vpt : DE•)F DEVELOPMENT . PLltt.:i r Pu r` . c e1 `. Nc 4.1;2 2304 -'90O .1 Si�,te Hdd s • s - 1x2 • 80 1.4 UK LA :E IERNATIo'i��lL R I_ • Tat"a1 :Fees« 2,013,7`.4' 4,.9.,11.1:00 t . •791 •. ; 4 •Total ALL: Pints 791 54 her' * t* *4A; * *k * *'h* *2 flick * *A. *. * *, ** **** A ***' ********kkk•h :it **k;i* r* R ecount ; ° Cc c1 Oe ;cr i:pit i are A nip un G {)p,O!'.34,5.5,3p' Pi- AN CHEC•1f': �- 140141 '.ES 791 .5.4 6 J U; U 0 N cn W, W I, 1--`. LLS Q W N = a W' Z l f... I— Os Z F--, :W O = W t • H U 0; Z; Z .; INSPECTION RECORb Retain a copy with permit - INSPECTIO NO. . 'CITY TUKWILA BUILDING DIVISION :6300 SouthCenter Blvd, #100, Tukwila, WA 98188 • . • PERMIT NO. (206)431-3670 Projett. s : ; Special instructions: Type of Inspection Date called: 1/2- Date wantrai: Requester: Phone: 3-40/3 Corrections required prior to approval. COMMENTS: 'Approved per. applicable codes. inspectf. Date: it $47.00 REINSPECTIrN FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: , t, Pro ect: 1` ey At pc l Or Type of Inspection: S nac t lcA + Address: 1 1 ` { 5 R V\L.w■ \cn. 11N+ 1. Date called: ` 11 Special instructions: Date wanted: ;".., (1 -=P -Q1 a.m. m. Requester: t f i Phone: INSPECTION RECO Retain 'a copy with permit INSPECTION NO. '.CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA. 98188 Approved per applicable codes. n Corrections required prior to approval: COMMENTS: ce \pe, I L f -- r Y11144 CAI") Y -Cr) I 1 { tr i), S � � UJe r to Inspectdi7 ` (� $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Date: Receipt No: tY: �P it pi 'P`ifl, :5?' •e s c s �h S %. aNi:,Fnt!..ic_T 1)o - )q . \ \ nc R Ty Inspecti n: r•-::, ' 1---P rrikt I • Addre • I )55,0 • - Li • Dmaii : /01 ,... Special instructions: 7 a) '1 Date wan in a.m. Requeste : M ■ ' • • • • •V , INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 • INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431-3670 - - COMMENTS: to / P-041 el/A(1 Inspector: L,.)<" Approved per applicable codes. El Corrections required prior to approval. Date: .1 4 2)i $47.00 REINSPECTION FEE REQ IRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: , .• • • •••i,"•.'''::!s,r.Q•i'44.' •••••,- • , • P oject: Y /in� Pe Ci I � Type�f�spection: .. TT //!�/ - - (h. Date calle : lo/ Address: /5&2D 7- , I Special instructions: /�j _ / • It/44i �,. .. if �. 1:30 ? rl Date wan d:J /0/g .lp/ a.m..' p.m. Requester: mf Pho e : 3,... ,,• INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188. Approved per applicable codes. COMMENTS: tl, 4 P � th\riV\-PPP tsrV4serJ c)a. S fr0614 4 Ov. S �r't1C. M �—e 1 t\`IQ t a '_ e l):AL 6e1 Inspector Date: ) CI_ ) n $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No: Date: INSPECTION RECORD Retain a copy with permit Corrections required prior to approval. (206)43'1 -3670 A4 A.14,.1. S Structural Engineers STRUCTURAL CALCULATIONS For Emergency Repair of Lewis and Clark Bowling Alley 15820 Tukwila Intl Blvd Tukwila, WA PLLC Sterling Realty Organization 600 106` Ave. N.E. Ste 200 Bellevue, WA. 98009 (425) 455-8169 D)ECEOVE Ill JUL 2 0 2001 REID MIDDLETON CITY O E TUK WILA JUN 2 9 2001 PERMIT CENTER 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512(V) (206) 285 -0618(F) o 9 C T ENGINEE I N G P L L C Protect: Le V,/ /.1 C/'•'/E" t/.//7/7 4 /pi i1 -- Client: ✓ " / /f/.4 Ai//,v fir; h• a /Pa, / 2.3 2X L wcid dee 4,v psf S%¢ far /Ms 3,0 psf /" /19/d rnsu/ 11 5 " Structural Engineers 1oPer7 of ex/ ,i arch A ssufne 9 /u- /ate �/zz.5 4nPrn /966" /`/e /d /n ` 6'fi ve/ue „ A = / /(3o -575) 339. G3 /n Z w- 09.6:' 5 /747,.G5 /'// z= 210, 979.4 fy2-7 /41/o w.-764_ comp-ens va /ue 115(/9 24F (/T5) / _ /G 5 2 psi' - P = �05. / .G So� r G:G -7? ( e 't ean �/dei - /,9 /n /na 01- eeper f/G Lill; 5 e• x/5744,9 /ondi /ioo5 '`u - /air arch / /3,o' spa:( » e ,14`o" :7:/D Q G'v pur /M 5 e :574y/3 d t B' wed tzr'f deck 2 x t- t4 1 /ci- lam arch k= go *A Date' Use /2 Psf a'Jer41' ri area {9/- sh 6 •5 56.5` f}= 56.5C4)_ /5G sift /3560(O,D/2)-/ 56 �" 3G i - / S(P (o •o75) = .zp a c. f f 180 Nickerson St Suitt 302 Seattle, WA 98109 1 -4 ( 0 -W M- -512 •FA.Xr. i•. • • Page Number (206) 28S =f1 &1 8 s5,2. - C T E N G I N E E R I N G P L L C l _ .r Project: /� / - i . iii' _! l �..-. L .. - / . %7 A /7e( Client: Structural Engineers Date: Page Number 180 Nickerson SI Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: (206) 285-0618 fror Gompufer output . 5 !/: e i .•/ f= 5' /.o AG 4910' l -\ 6--- 74,3214 , 17, e 7' , 63, e2" feer es 6 77 f,3/%k = Co/25 /6"4:fr 51e G/ 4 .0/7 ie = z /.56/s/ - &7,o K5/ k 5 �' 7" /6 X 2 ¢ ,o /-c7/c .607'12 s /des f r9 .' ., . G3, q1= 3? / >z 5= 2(0.625(9 ) = Ao/fs fo /-r?nsict- axial 1 /r t/. a k bolt va /u& 8 6.52 w /5/e / 5 a' ,/Afcs daub /eshat shot f /tine /aad e /, /5 e //5(5.52) F - ' /, ( iz l = 3 �` 123 = G 3S _. 5, 3 G�fs t1SC (to) 7 , b /.b darn -z7 . 'S' 1 _2156. 27 eh/9 � tote: c-Xr' ! . = 3.27 A /. 32 5/ ( / = 6,i.. /c5 �. o • 34 , /2) top > 6,7}o n -3,r spa i/y sa 4.4„:twa;xfIVA5h562' !« -:isa, r,. w o O N° W CO IL w O. co 3. I - w z 1--. O . z � w mo o . o N' O H, W w' = V, z• 0 I . z C T E N G I N E E R I N G P L L C Protect: Z!. f / //` ' C4Q / - /s bow //1 4-/ /ey Client: SRo sk71 /C0 1/v.. d er /n/catc Arch Ora //s!s _ Did /oad o/7 /y q25 i 1 _ //3) /-5 A/ -- 4,30(5-0 2 Q'25 f ? fi r , ) Ay -- ,Z 2 ..1/ - pv, 5 //), — 414 Dead t 25P5f .5/7'W Load 0.98 ( t'2slo•8/ .0.. qg (60 7 a / 2. 74,4/ f 926 � / /3py �-26E,Q Gz &Z +eL/B q 2s,' - / /3A5 t- GZ66 25.5 � - G t 003 5-eC corrpa 4/1 a/ 40" yrr. .,5" a - o/2. (24) f o . o 9 = 0.38 k/, 925 /i,3 o2yz;. i 1 J :/..zs 5/ '/9`r`. /qi fix, = 294 /� xa: ::: Z Ay/ /9.a� gy2 = � k/, kV:: D - .P Fo.ozs`2e4= O.9B //3 [q.25 /G•2s' S/ p 4 75,888 Gr �y 4/./c A5/ a 1,546l r 9 , 7 _//3 t - Gasp ,8I - /BO 3•SC. 1 Structural Engineers Date: 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285.4512 FAX: Page Number: (206) 285-0618 i4. ✓ zip... »;1r�r..iL1`•rk' ECG':?. ii`:. zY3.:} l�' G':' v;) r' s. s. 'itut <lu tif,.rfk4�.'4? r 4:rk C T E N G I N E E - I N G _ PLLC Project: L ka'' C/ / fc" I'J / //j ,4 / / — Client: SA ` e) Structural Engineers Date: 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285.4512 FAX: Page Number: (206) 285 -0618 M f/2 f e by arch . oesr2 51e {,» te/75 /o/2 IA/o rs 2t a. a/76.1/21-5 3z of c, o7 ,Yra // 6/. f iz Gam ufcr oc f ut ComP 12-1-53/10 r/ r� // k �sf�cl� /cJ7�c 5/1 Q // r ♦ 'r • • 2 lePaPe, ' /1 = cv = /G. // b /G•//(1/) / / . /774/ // Z ! / (20) f // )(ie z. '1- /77.2/(0-3.1)3 / ) , 2 6 0 - . 2 . 5 1 ( / / ) 4qe74/7//73 S r. 54. r- 1/ k l/ S 24614./7_ /, 73. 5 47 / / fr, Zo ,_1=i2,o' 1 _ /d,0 ( /z)_ �. D�� (<410 = 0.74 1c51. arm. f 3/ 64 7 42,0 (i z! : G. a e 1 / 30.25 Q= o. z (/ /2 (< yr ( n ) 0,/z 9 /bq4. 7/ Use / !q 5&- 'Ws e /2 11 0.6 . 5fa flereG. )f /l "x %¢ x e 5m a// CtcckMe 4:; S (2) /G.// . 62 */ O 3/ 4 (6, S `i 2) . p, r 5 K51 pi_ • /7 ?7/ : z .J U o 0 ' tf W I- LO : w o -a w z � � Z wur � 0 • 0' w • w V ui z, - =s o z C T E N G I N E E I N G P L L C 1," L ew/ s Clerk e,,w //, ,4 //c Project: 572 A4a/ch /i er'/ l ok i/e G0'7/2ec lion ,V/m/27u/72 Wpb /) /a'ie 'rye 3 Use (3) x/4.''44 bo /r !n/ /r '/ d >At- ashero. Structural Enoineere Date: 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: Page Number: (206) 285-0618 rn in{ (9 SCALE. Vz" •• • I • : i ELEV. 377.5 I f__o ._ 0 .. SEC.T101■3 I.2:0T E : FoR A DITIOLIAL IMPOZ/AL.- 13 TrOL4 AND DET..6.1 LS E. SECT 01.1 2:- - • - • SI - V 0 N ZC S AT .t.LL BE FAS Z1C %,"; • • tf; • •A •••• .hz ... • . ••• 1.4 111, C L E. : = en" 115' - 0" r. 51-1E&T t.1 IL! D T ZS! 1 L SCA.LE " = P- a" . - 6:se " E. /--t OF AILCti sa. • el= • 14 ' tt; tt, AA SEE. DETAI L J I VD' •••••• •• • I I Top-of cuzE5s t _ 0 - poF cur if WO FOR-1T FO DI /AL I OKI SAOWILI _ - — .T.*Ydne !.1" GLU -LAM — 1 1"x 30741" GLL1-1.LVA A2C.1-1 SECTI01-1.. 514 *N. I • (.; .5 0 L .—CO 1.1E 1') 514 TM _D BY THE - L 4 T E zc 111 0 c, a GE E- D g AZC. cl }••• EV 4 Si. e.1 .,.; N 1Z. tv A C rrEc.7 v .‘"? 1 r 'A ADD t) LA! 0.I t T EE_ ARC UCT. • /1151 OF W a" E FACE : L NOTICE: IF THE DOCUMENT O IN THIS FRA DOCUMENT ME IS LESS CLEAR THAN THIS NOTICE IT IS DUE T THE QUALITY OF THE . a B) Q3 v li 374_ ELEV. 371 . 54 ?'? 6-P ILIA N.5 Z [I EARAL T r:. a A r7 :I:C . 0 VI LI 5 . - ECTI LI —1 Ni i I il- s • . 3A"4113•61Z.S o %9 • • \I \;.'-' 5140 -- ; 1 i ....../ s• , N, J ' ax Jot N. . oF EL EV. 373 -(.... !Ft ..14.”..c Y•rx I .- 0 . 9"x Vz" x. 0 '• LUBZITE Ft_ 'd3 BAZS \VELD - ro ,^Z _12"x Vz" 4 5 _ GZOU T ..... 1.-- SU E CowEL: Steel Code AISC 9th Edition ASD Allowable Stress Increase Factor.(ASIF) 1.333 Include Shear Deformation Yes No.: of Sections for Member Cates . 5 . . • Redesign Sections No P -Delta Analysis Tolerance 0.50 % M1 N1 N2 Reaction SEG '::; : :N21 .:.::..... :::Reaction 6.451 M2 :. N2 . N3 . SEG 5.917 M3 N3 N4 SEG 5.595 kmpany : CT Engineering P.L..L.C. Designer : Chuck Dinsmore Job Number : 0.1033 Global Joint Coordinates Joint Label N1 N2 N3 N4 • N5 N6 N7 N9 N11 N12 _ . N13 N14 N15 N17 : N19 ;N20 N21 0 5.1 10.2 15 :3 ':. 20.4 25.5 30.6 35:7 40.8 45.9 51 .57.2 63.4 . -69.6 • 75.8 :482 • 88.2 94.4• 100.6 106:8 113 9.25 13.2 16.2 18.5 - 20.8 22.8 24 24.5 ..` 25 25.2 25.5 25.2 24.8 22.4 '20:3 17.2 -14 .' 10.2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Boundary Conditions Materials (General) Material Label Young's Modulus Shear Modulus Poisson's Thermal Coef. Weight Density . Yield Stress WOOD I 1 00 I ( .54 ) I Ratio I (per 6 5 F) I ( .038 I ( 0 i) Joint Label X Translation Y Translation Member Data Win X Coordinate (Ft) Member Label I Joint J Joint K/in RISA - 2D Version 5.1 [C :lrisa\Srolcl.r2d] Rotate Lewis and Clark Bowling Alley Y Coordinate (Ft) Rotation ' K W ad Section Set l I% Joint Temperature (F) End Releases I -End J-End AVM AVM April 4, 2001 2:09 PM Checked By: End Offsets Inactive Member I -End J -End Code Length In In (Ft Page 1 14 et: »: fuii: z w CL 2 U0 N 0 J • = N u w g u-¢ = d w z � o z 1-- U � O � 3 F- w • w. L I O .. z w F ▪ - O I z N1 Reaction Reaction '::; : :N21 .:.::..... :::Reaction .:Reaction kmpany : CT Engineering P.L..L.C. Designer : Chuck Dinsmore Job Number : 0.1033 Global Joint Coordinates Joint Label N1 N2 N3 N4 • N5 N6 N7 N9 N11 N12 _ . N13 N14 N15 N17 : N19 ;N20 N21 0 5.1 10.2 15 :3 ':. 20.4 25.5 30.6 35:7 40.8 45.9 51 .57.2 63.4 . -69.6 • 75.8 :482 • 88.2 94.4• 100.6 106:8 113 9.25 13.2 16.2 18.5 - 20.8 22.8 24 24.5 ..` 25 25.2 25.5 25.2 24.8 22.4 '20:3 17.2 -14 .' 10.2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Boundary Conditions Materials (General) Material Label Young's Modulus Shear Modulus Poisson's Thermal Coef. Weight Density . Yield Stress WOOD I 1 00 I ( .54 ) I Ratio I (per 6 5 F) I ( .038 I ( 0 i) Joint Label X Translation Y Translation Member Data Win X Coordinate (Ft) Member Label I Joint J Joint K/in RISA - 2D Version 5.1 [C :lrisa\Srolcl.r2d] Rotate Lewis and Clark Bowling Alley Y Coordinate (Ft) Rotation ' K W ad Section Set l I% Joint Temperature (F) End Releases I -End J-End AVM AVM April 4, 2001 2:09 PM Checked By: End Offsets Inactive Member I -End J -End Code Length In In (Ft Page 1 14 et: »: fuii: z w CL 2 U0 N 0 J • = N u w g u-¢ = d w z � o z 1-- U � O � 3 F- w • w. L I O .. z w F ▪ - O I z M4 N4 N5 SEG 5.595 M5 N5 N6 SEG 5.478 M6 N6 N7 SEG ' . 5.239 M7 N7 N8 SEG 5.124 M8 N8 N9 SEG 5.124 M9 N9 N10 SEG 5.104 • M10 :: N10 N11 SEG PIN 5.109 M11 N11 N12 SEG 6.207 'M12 :.:. N12 N13 SEG 6.213 :..: M13 N13 N14 SEG 6.265 M14 N14 N15 • SEG 6.379 M15 N15 N16 SEG 6.546 M16 N16 -.N17 :.. .. SEG • : •. 6.932 M17 N17 N18 SEG 6.977 M18 N18 N19 SEG .... :. 7.272 M19 N19 N20 SEG 7.965 M20 :. .• N20 N21 ... ;. SEG ... 8.092 Company : CT Engineering P.�.L.C. Designer : Chuck Dinsmore Job Number : 0.1033 Member Data (continued) Member Label I Joint J Joint Sections Section Label SEG Basic Load Case Data BLC No. Basic Load Case Description Category Code Lewis and Clark Bowling Alley Rotate decrees Section Set RISA - 2D Version 5.1 [C:1risa\Srolcl .r2d] Category Description End Releases I -End J -End AVM AVM Database Material Area SA SA I (90,270) Shape Label (In) ^2 0,180) (90,270) (In ^4) I WOOD I 339 J 1 1 1 I 26979 Member Distributed Loads, Category : None, BLC 1: Dead Load April 4, 2001 2:09 PM Checked By: End Offsets Inactive Member I -End J -End Code Length In In (Ft Gravity Load Type Totals X Y Nodal Point Dist 20 1 Dead Load Snow Load:. • None None : - : . -1 20 Member Label I Joint J Joint Load Pattern Label Pattern Multiplier M1 M3 M5 M6 M7 M M9 : : M10 M11 M12 M13 M14 M15 : M16 M17 M18 N1 N2..: N3 .... •N4 N5 N6' N7 N8 N9 N10 N11 • N12 N13 ••N14 • N15 N16 N17 N18 N2 N3 ... N4 ...:N5;: N6 N8 N9 : N10 N11 N12 N13 N14 N15 N16 N17 N18 N19 UNID •UNID UNID UNID . ::::::_. -:: • UNID ::UNID .' UNID _ UNID UNID :UNID • UNID "UNID UNID -UNID UNID UNID .29 .29 :._ .29 .29 .29 .29 .29 -29 .29 .29 .29 .29 .29 . 29 .29 . 29 .29 .29 I (0,180) T/C (In ^4) Only 3424 Page 2 vi: ". ;s : ia''dff;t:: +% li .iail.`s:y:5it�(t: {ABd' ice: ix' s4:iM t :Vi M19 N1 N20 UNID 0.000 0.000 N20 0.016 UNID .: .29 N3 -1.014 1.39 0.003 N4 :. .:: : ' -0.988 ' .1.309 -0.005 N5 -0.731 0.717 -0.014 .... : N6 :::::. ..0:279: -0;46 : . - 0.025 .. N7 0.141 -2.281 -0.034 NS - ... ... 0.36 ..: -4.598 . -0.04 :.. N9 0.6 -7.125 -0.042 : :_ .:, N10 " :... .. ; : 0:692 ..:. ::_0:041 N11 0.83 -12.15 --0. N12 1?141 .... .. 0.05 N13 1.229 -4.754 0.048 M19 N19 N20 UNID .29 M20 N20 , ..N2.1 UNID .: .29 Qompany : CT Engineering F ..... Designer : Chuck Dinsmore Job Number : 0.1033 Member Distributed Loads, Category : None, BLC 1 (continued) Member Label I Joint J Joint Load Pattern Label Member Distributed Loads, Category : None, BLC 2 : Snow Load Member Label I Joint J Joint Load Pattern Label M1 M2 M3 .M4 M5 M6 M7 M8 M9 • .M10 M11 M12 • M13 : : M14 . '.. M15 M16' M17 M18 M19 =M20 N1 .N2 N3 N4 N5 N6 .: N7 .N8 N9 N10 N11 N12. N13 'N14 N15 .N16 N17 -N18 N19 N2 N3 N4 N5 N6 N7 _ N8 N9 N10 'N11 N12 -N13 N14 .N15 N16 :.: =N17 ... N18 N19 N20 N21 UNIL UNIL UNIL UNIL .. UNIL UNIL UNIL UNIL UNIL UNIL UNIL UNIL UNIL ::UNIL UNIL UNIL UNIL UNIL UNIL UNIL -.6 -.6 -.6 -.6 -.6 -.6 -.6 -.6 -.6 ..6 .. -.6 -:6 -.6 �6 -.6 -.6 -.6 -.6 Load Combinations Num Description Dead Only 1 1 1 J...2 . 1 . , . Snow Only . : .1 1 ' :::1 : 1... .1 .. .: I 3 1 Dead + Snow 1 1 1 1 1 1 1 1 1 2 1 1 Joint Displacements, LC 3 : Dead + Snow Joint Label X Translation In RISA -2D Version 5.1 [C:Visa\Srolc1.r2d] Lewis and Clark Bowling Alley Env E WS PD SRSS CD BLC Factor BLC Factor BLC Factor BLC Factor Y Translation In Rotation ( radians ; April 4, 2001 2:09 PM Checked By: Pattern Multi p lier Pattern Multiplier ft.T Page 3 • N14 1.712 • -1.359 0.042 N15 2.376 1.429 0.032 N16 • 3.019. 3.361 • -0.019 N17 3.48 4.309 0.007 N18 3.513 • 4.399 • -0,005 N19 3.014 3.61 -0.017 N20 • 1.683 .1.982 -0.026 N21 0.000 0.000 -0.027 I M1 1 91.933 -7.139 0 2 91.09 -8.227 12.39 3 90.247 -9.316 26.536 4 89.404 -10.405 42.438 5 88.561 -11.493 60.095 M2 . --. - '. 1 89.303 . ' -0.159 60.095 - - 2 - 88.631 1.302 - 61.175 3 • 87.958 - -2.445 - - - .63.947 4 • 5 87.286 •• -3.588 . • 68.409 • ' -86.613 • 4.731 - 74.562: ' I M3 1 86.618 4.637 74.562 2 86.086 3.456 68.903 3 85.553 2.275 64.895 4 85.02 1.093 62.54 5 84.488 -0.088 61.837 . - 1 . ' .- 84.488 . . - -0.088 ' • -,...- . - "- 2 - •' 83.955.: ::-t269 - :- 62.785 . 65.386 - .- .. . 3 83.422 -, -: . -. - . -2.45 - - • 4 ' - 82.89 -: _ - -3.631 •• . 69.639 -. : -. I M5 1 82.494 -0.695 75.544 2 82.025 -1.891 77.315 3 81.556 -3.087 80.724 4 81.087 -4.283 85.77 5 80.618 -5.479 92.455 I . :* . * - M6 - . 1 - - 80.579 - - .- . - - 92,455 2 . '80.289 -.. 4.808 - - 85.353 3 . 80 :"--: - 3.58 . 79.859 . 4 ' 79.711 . -• 2351 • 75.975 ' 5 79422 . 1.123 73.7 I M7 1 78.568 11.674 73.7 2 78.446 10.428 59.542 3 78.324 9.183 46.98 4 78.202 7.938 36.013 5 78.079 6.693 26.641 I - " • MB • - . 1 .78.079 6.693 26.641 • 2 • 77.957. 5.448 • 18.864 • 3 77.835 4203 12.682 4 77.713 2.957 8.096 • 3 3 3 Company : CT Engineering P.....L.C. Designer : Chuck Dinsmore Job Number : 0.1033 Joint Displacements, LC 3 : Dead + Snow, (continued) Joint Label X Translation In Member Section Forces, LC 3: Dead + Snow Member Label Section Axial K RISA-2D Version 5.1 [C:\risa\Srold.r2d] Lewis and Clark Bowling Alley Y Translation In Shear (K) Rotation radians Moment ( K-ft ) April 4, 2001 2:09 PM Checked By: Page 4 •. • • 61i4",i3!-',Vai,e.:46,,,,Alia-.11.q4r.'4.3',3:.,-Tt. Company : CT Engineering F.�.L.C. Designer : Chuck Dinsmore Job Number : 0.1033 RISA -2D Version 5.1 [C Arisa \SroIc1.r2d] Lewis and Clark Bowling Alley Member Section Forces, LC 3 : Dead + Snow, (continued Member Label Section Axial Shear Moment (K) (K) (K ft) April 4, 2001 2:09 PM Checked By: M9 M10 M11 .M12 M13 M14 M15 M16 . M17 : M18 M19 1 2 3 4 5 1 2 3 4 5 3 ... 1 2 3 4 5 • 2 ,- 4 1 2 3 4 5 1 1 2 3 4 5 2 .3 • 4 5 77.591 77.358 77.309 77.26 77.211 77.162 77.172 77,099 77.025 76.952 76.879 76.999 77.072 77.145 77.219 77.292 • 77.332 77.429 = °. :77.527 77.625 77.723 78.104 78.323 78.542 78.761 78.98 • 79.354:: _ .: •:- 79:715 80.076 - :.80.798 •. : 81.037 81.535 82.032 82.53 83.027 82.924 83.634 85.054':. .85.764 85.747 86.477 87.207 87.937 88.667 88.706 :. 89.553 .: 90.399 91.246 92.092 1.712 6.248 5 3.752 2.504 1.255 -0.254 -1.502 -2.749 -3.997 -5.244 3.004 1.487 -0.03 -1.547 -3.064 1.821 -3.337 • :- 4:853 . . -6.37 -7.886 . -1.671 -3.179 -4.688 -6.196 -7.705 =1:812 -3.304 . 4.796 x.288 0.935 -0.534 -2.003 -3.472 -4.941 6.45 5.03 3.61 -2.19 .0,77 1.87 0.455 -0.959 -2.374 -3.788 2.723 1.342 -0.039 -1.42 -2.802 9.051 5.105 5.105 -2.072 -7.655 - 11.646 - 14.044 -14.044 - 12.923 -10.209 -5:901 0 -3.485 -4.616 -3.393 0.185 .0.185 4:191 10.551 .: 19.267 30.338 30.338 34.136 40.297 48.82 59.707 39.707_ • : :61.406 ••• 65.484 -71.942 :. =80:78 : 80.78 80.451 82.526 87.006 93.889 93.889 83.941 76.454 71.428 68.862 68.862 66.834 67.274 70.181 75.555 75:555 71.86 70.677 72.003 75.841 91.689 75.841 Page 5 2 92.747 7.739 59.124 3 93.805 6.427 45.02 4 94.863 5.115 33.529 5 95.922 3.803 24.65 1 95.831 5.648 24.65 2 96.922 4.347 14.54 3 98.013 ' 3.046 7.062 4 99.103 1.746 . 2,215 5 100.194 0,445 0 1 M1 1 0 0 NC 2 -0.003 0.315 3179.338 3 -0.006 0.622 1957.073 4 -0.009 0.909 2192.722 5 -0.011 1.164 NC M2 . ' 1 -0.159 1 - . .-NC . -2 • •-0.162 • • 1:351 1216.114 3 : - -0.164 1.512 897.033 4 ' -0.167 1.633 . - 1171;589 5 . -0.169 - -- 1.712 . NC • • I M3 1 -0.353 1.684 NC 2 -0.355 1.718 1224.441 3 -0.358 1.714 935.143 4 -0.36 1.674 1264.69 5 -0.362 1.6 NC 2 . - • - -:0.365 • •-• ..: 1.492 . -.. 1256:725 _ :3 • -• -0.367 ...: .. • 1.349 . - 928.183 - 4 • !, . - --0.369 ' - 1.171 . 4214.012 5 * -0.372 - .- -- 0.954 - .... NC . I M5 1 -0.419 0.934 NC 2 -0.421 0.682 1041.759 3 -0.423 0.39 769.083 4 -0.425 0.054 1006.303 5 -0.428 -0.326 NC M6 ' . 1 -0.377- ... -0383 . - . ..-NC - - 2 . * . -0.379 - . -0.792 . 154.06 ' ' 3 .0.381-:: • -t241 - 73.335 •• 4 - .0.383 . ':4.729:.::.' 46.744 5 - . -0.385' • . . -2.253 33.633 M7 1 -0.082 -2.284 NC 2 -0.084 -2.83 112.597 3 -0.086 -3.404 54.918 4 -0.088 -3.999 35.856 5 -0.09 -4.611 26.427 I M6 1 -0.09 -4.611 - NC 2 -0.092 -5.235 98.511 3 . -0.094 . -5.868 48.913 Company : CT Engineering P.L.L.C. Designer : Chuck Dinsmore Job Number : 0.1033 Lewis and Clark Bowling Alley Member Section Forces, LC 3 • Dead + Snow, (continued) Member Label Section Axial 1 M20 K Shear Moment K-ft Member Deflections, LC 3: Dead + Snow Member Label Section x-Translation y-Translation (n) Uy Ratio In RISA Version 5.1 [CArisa\Srolc1s2d] In April 4, 2001 2:09 PM Checked By: Page 6 4440,0410.c' io■■40A41P,4, 4.7 .riscrA■03 1, 0 , 4d0at 4,1 :4;1' , 1 , ..!+1,, , Wi'l \ Company : CT Engineering P.....L.C. Designer : Chuck Dinsmore Job Number : 0.1033 Lewis and Clark Bowling Alley Member Deflections, LC 3 : Dead + Snow. (continued Member Label Section x- Translation (In RISA - 2D Version 5.1 [C :Visa \Srolc1.r2d] y- Translation (In) (n) Uy Ratio April 4, 2001 2:09 PM Checked By: M9 M10. : : .. M11 M13 } M14 M15 M16 • M17 • M18 4 5 1 2 3 4 5 1 2 3 4 5 3 1 2 3 4 5 `L] : :5 1 2 3 4 5 4 1 2 3 4 5 2 • 4 5 - 0.096 -0.098 0.321 0.319 0.317 0.315 0.313 0:123 •0121 0.119 0.117 0.115 1.417 1.414 1.412 1.41 1.407 1.542 • 1.539 = .1 1:535 1.532' • 1.899 1.896 1.894 1.892 1.889 :983.:;. 1 :981 : = 1..976 1 :973 1.792 1.789 1.787 1.784 1.781 1.197 1.194 ..:.:1.191 1:189 1.186 1.116 1.113 1.11 1.107 1.104 0.697 0.693 . 0.69 0.687 0.684 6.507 -7.15 -7.143 -7.785 -8.426 -9.064 -9.697 -9.701 - 10.328 10.949 11.565 -12.179 - 12.097 - 11.172 - 10.245 -9.315 -8.383 - 8.359 -7.427 -6.497 ..5:574 • -4.665 -4.528 -3.631 -2.757 -1.911 -1.099 • -0 :918 - 0133 1.304 . 1.948 2.116 2.718 3.259 3.739 4.152 4.357 4.721 5.014. 5.242 5.41 5.425 5.535 5.589 5.585 5.521 5.587 :5A53 5.252 4.986 32.432 24.222 NC NC 9416.322 NC NC NC 8339.658 6925.344 NC NC NC NC NC NC NC 20.178 26.993 40:694 81.978 NC 21.926 29.698 45.347 92.577 NC :NC • 1105:839 • • .809.885. 1048 :916 NC 846.023 627.724 824.18 NC NC : -.: 827.761 639.224 • ..:873 :557 I NC 965.887 720.67 950.24 NC NC 875.618 658.416 875.036 NC 4.653 nra.pen!�pl Page 7 N1 M19 1 0.08 4.702 NC • . 64.045 . 0.000 2 0.077 4.26 1137.832 3 0.073 3.753 936.75 4 0.069 3.195 1369.838 5 0.066 2.599 NC I.. : M20 . 1 0.016 :2.6 : NC .. 2: 0,012: 1.968 5524.235 3 0.008 1.318 .. 5329.572 `4 •. 0.004 0.661 :9242.034: 0 NC . ,, N1 77.054 50.65 0.000 :.::. , N21 = - 77.054 .: • . 64.045 . 0.000 Reaction Totals : 0.000 114.695 ;•s Company : CT Engineering F....L.C. Designer : Chuck Dinsmore Job Number : 0.1033 Lewis and Clark Bowling Alley Member Deflections, LC 3 : Dead + Snow, (continued) Member Label Section x- Translation y- Translation (n) Uy Ratio Reactions, LC 3 : Dead + Snow Joint Label X Force K In (In RISA - 2D Version 5.1 [C:Visa\Srolc1.r2d) Y Force (K) Moment ( K-ft ) Center of Gravity Coords (X,Y) (Ft) : 56.882 1_ 18.784 April 4, 2001 2:09 PM Checked By: Page 8 Seution LC 3. Mad •Snow LNnMr L.., ,5 Wm/ft sk. ) CT Engineering P.L.L.C. Chuck Dinsmore 0.1033 Lewis and Clark Bowling Alley 5 April 4, 2001 2:02 PM Sroicl .r2d NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE,TO THE QUALITY OF THE DOCUMENT Sniren W Steel Code AISC 9th Edition ASD Allowable Stress Increase Factor (ASIF) 1.333 Include Shear Deformation Yes No. of Sections for Member Cates 5 Redesign Sections No P -Delta Analysis Tolerance 0.50% N1 Reaction Reaction N21. ... Reaction ": . 'Reaction ,Compan : CT Engineering F ._.L.C. - 4tp r/fr March 30, 2001 ,� Designer : Chuck Dinsmore l ', c 2:08 PM Job Number : 0.1033 Lewis and Clark Bowling Alley Checked By: Global Joint Coordinates Joint Label N1 N2 N3 :.N4 N5 N6 'N7 �N8 N9 .N10 N11 N12 N13 • N14 N15 ._N16 :::: N17 =N18 N19 N21 ( 0 5.1 10.2 15.3 20.4 25.5 30.6 .35:7 40.8 45.9 51 57.2 63.4 69.6 75.8 82: .. 88.2 94.4 100.6 106.8 113 ( 9.25 13.2 16.2 18.5 20.8 22.8 24 24.5 . 25 .25 25.5 25.2 24.8 23.9 22.4 20.3 17.2 14 10.2 ,. 5:2. :. 0 0 0 .:0 0 :. . 0 0 . 0 0 0 0 0 Boundary Conditions Joint Label X Translation ( K/in ) Materials (General) Member Data Member Label I Joint X Coordinate Ft) J Joint Y Translation ( K/iin ) Y Coordinate Ft) Rotation K-ft/rad Section Rotate Set (degrees) Joint Temperature (F Material Label Young's Modulus Shear Modulus Poisson's Thermal Coef. Weight Density Yield Stress WOOD t 1 00 ( 4) I Ratio I (per 6 F) ( ( .038 I (Ksi) 0 i) End Releases End Offsets Inactive Member I -End J -End I -End J -End Code Length AVM AVM (In) (In) (Ft) M1 N1 N2 N2 N3 SEG . SEG 6.451 5.9 RISA -2D Version 5.1 [C:\risa1Srolc1.r2d] Page 9 z z 00 CO 0 CO J U) U W 2 1 J U d W H Z ZO LU Lu 0 o l- U I -- r __ . ' u- O .. z' w U= O ~ z M3 N3 N4 SEG 5.595 M4 N4 N5 SEG 5.595 M5 N5 N6 SEG 5.478 M6 N6 N7 SEG 5:239 M7 N7 N8 SEG 5.124 M8 N8 N9 SEG 5.124 M9 N9 N10 SEG 5.104 M10 •N10 N11 .SEG 5.109 - M11 N11 N12 SEG 6.207 M12 N12 N13 .SEG 6.213 M13 N13 N14 SEG 6.265 ' :M14 • ` N14 N15 . .: SEG 6.379 M15 N15 N16 SEG 6.546 ..:'M16 :.. N16 : SEG :... 6.932 M17 N17 N18 SEG 6.977 :;. M18 N18 . N19 • SEG . 7.272 M19 N19 N20 SEG 7.965 M20 N20 . : ' N21 .: SEG 8.092 Company : CT Engineering P....L.C. Designer : Chuck Dinsmore Job Number : 0.1033 Lewis and Clark Bowling Alley Member Data (continued) Member Label I Joint J Joint Sections Section Label SEG Database Sha Basic Load Case Data BLC No. Basic Load Case Description Category Code Material Label WOOD 1 Dead Load Snow Load None -None - 1 20 Member Distributed Loads, Category : None, BLC 1: Dead Load Member Label I Joint J Joint Load Pattern Label Pattern Muttiplier M1 1A2 • M3 ::M4 • M5 •M6 . • M7 :M8• M9 M10 M11 M12 M13 M14 M15 • M16 N1 N3 N4 .:::::::.: N5 :.N6 N7 N8 .:: N9 • -N10 N11 N12 N13 N14 N15 N16 N2 N4 N5 N6 N7 N8 N9 N10 • - Nil N12 ::N13 N14 N15 N16 N17 UNID UNID'.• UNID :UNID UNID 'UNID UNID UNID : UNID 'UNID UNID • ` -UNID UNID UNID UNID UNID .29 • .29 _.29 .29 .29 .29 .29 .29 • ....:29 .29 .29 .29 .29 .29 RISA -2D Version 5.1 [C :\risa \Srolc1.r2d] Rotate decrees Section Set Category Description Area (In ^2 End Releases I -End J -End SA I (90,270) (0,180) 90,270) In^4) SA 339 1 1 March 30, 2001 2:08 PM Checked By: End Offsets Inactive Member I -End J -End Code Length 1 (0,180) TIC (In ^4 OnI 26979 3424 Gravity Load Type Totals X Y Nodal Point Dist. 20 Page 10 N1 N17 0.000 UNID 0.000 M18 0.011 . N19 .UNID - 0.504::.. :.. 0.633 N19 0.008 N3 .29 -0.69 : N20 0.929 UNID 0.002 N4 -0.66 ....:. .: 0.84 • .... -0.004 N5 -0.502 0.469 -0.008 -0.248 -0.202 -0.014 N7 -0.023 -1.194 -0.018 N$ ..:. 0.081 - 2.334. : -0.018 N9 0.17 -3.321 -0.014 N10 0.187 3:952 0.007 M17 N17 N18 UNID .29 M18 N18 . N19 .UNID .29 M19 N19 N20 UNID .29 • M20 : N20 N21 UNID .29 -- Company : CT Engineering P.L.L.C. Designer : Chuck Dinsmore Job Number : 0.1033 Member Distributed Loads, Category : None, BLC I (continued) Member Label I Joint J Joint Member Distributed Loads, Category : None, BLC 2 : Snow Load Member Label I Joint J Joint Load Pattern Label M1 M2 . .: N2 N3 M3 M4 M5 M6 M7 M8 M9 M10 . M11 M12 •': M13 M14 M15 *M16 M17 : M18 M19 N1 N2 N3 N4 N5 N6 N7 ,N8 N9 N10 - N11 N12 N13 N14. N15 N16 ....• N17 N18 N19 N20 ..: N4 N5 N6 N7 N8 N9 N10 N11 N12 .N13 N14 N15 N16 :N17 N18 N19 N20 :` 121 UNIL UNIL UNIL UNIL UNIL UNIL UNIL UNIL UNIL UNIL UNIL UNIL UNIL UNIL UNIL UNIL UNIL UNIL UNIL . -.6 -.6 -.6 - 6 -.6 -.6 -.6 -.6 -.6 -.6 -.6 - -.6 -.6 -.6 -.6 -.6 - .. -.6 -.6 Load Combinations Num Descri Env WS PD SRSS CD BLC Factor BLC Factor BLC Factor BLC Factor I 1 I Dead Only I I l I 11 1 1 l .2 I •Snow Only :1 .:::.1 ...:1 : I 1 . 2: 1 3 I Dead + Snow I I I I 11 1 1 Joint Displacements, LC 3 : Dead + Snow Joint Label X Translation Y Translation In (In RISA -2D Version 5.1 [C :Uisa\Srolc1.r2d] Lewis and Clark Bowling Alley Rotation ( radians ; March 30, 2001 2:08 PM Checked By: Pattern Multiplier Page 11 N11 0.189 X12 0.001 N12. 0.199 -3.712 0.01 N13 0.254 -2.726 0.016 N14 .0.434 • ' - 1:421 0.018 N15 0.74 -0.114 0.016 N16 1.082 0.927 0.011 N17 1.378 1.545 0.006 N18 .. ...... "1.501 1.808 . 0.001 N19 1.364 1.608 -0.007 :. N20 ..... 0.769 0.893 . 0.012 . . N21 0.000 0.000 -0.012 M1 1 89.91 -5.289 0 2 89.067 -6.378 9.408 3 88.224 -7.466 20.571 4 87.381 -8.555 33.49 5 86.538 -9.644 48.164 M2 . .. 87.062 1.419 ' 48.164 2 . ' 86.389 : ' : 0.276 46.91 3 85.717 ' -0.867 47.348 4 -85.044 '. -2.01 :. - 49.476 5. : 84.372 ... - 3.154..:. 53295 M3 1 84.22 5.964 53.295 2 83.687 4.783 45.78 3 83.155 3.602 39.917 4 82.622 2.42 35.705 5 82.089 1.239 33.146 [:• ::.':'. :. -.: M4 . ; ..,.:::.: .1 ... 82.089 .1.239: • ... .. 33:146 .:.:::: .._:2 ;,: 81.557 .: .. ..:0.058 - : '32239 3 ' 81.024 ` - 1.123: . - ... 32.984 : • :.:80.491 : .. ::..: -2.304 .:35.381 ::.::... 79.959...': > ..'; .-3.485 : °' . 39.43 : M5 1 80.033 0.51 39.43 2 79.564 -0.686 39.549 3 79.095 -1.882 41.307 4 78.626 - 3.078 44.703 5 78.157 -4.274 49.737 ....... M6 1 .. � � . 77.871 ' � 6.88 49:737 2 77.682. . : '5.652 41.53 3 . ' 77.392. :. 4.423. 34.932 77.103 . ' :3.195 - 29.943 .. • 5 ' . . 76.814 :1.966 • • . 26.563 - • M7 1 75.871 12.163 26.563 2 75.749 10.917 11.778 3 75.627 9.672 -1.41 4 75.505 8.427 - 13.004 5 75.383 7.182 - 23.003 -. Company : CT Engineering P._.L.C. Designer : Chuck Dinsmore Job Number : 0.1033 Lewis and Clark Bowling Alley Joint Dis . lacements LC 3 : Dead + Snow continued Joint Label X Translation In Member Section Forces, LC 3 : Dead + Snow Member Label Section Axial K RISA - 2D Version 5.1 [C:\risa \Srolcl.r2d] Y Translation Shear (K) Rotation :r 4w r a iar - �ncl Moment ( K -ft March 30, 2001 2:08 PM Checked By: A�(i -t*'~et/ ar�ly Page 12 Company : CT Engineering P.1_.L.C. Designer : Chuck Dinsmore Job Number : 0.1033 Lewis and Clark Bowling Alley Member Section Forces, LC 3 : Dead Member Label Section Axial K) M8 M9 M10 M11 M12 M13 14 M15 .M16 M17 1 2 . 3 4 1 2 3 4 5 . 3 1 2 3 4 5 1 2 4 5 1 : ..... .'::3 1 2 3 4 5 3 .... 1 2 3 4 5 M18 1 75.383 75.26 75138 75.016 74.894 74.637 74.588 74.539 74.49 74.441 :74.458 '74.385 74.311 74.238 74.165 74.259 74.333 74.406 74.479 74.553 74.591 74.689 74.787 74.884 74.982 75.368 75.587 75.806 76.025 76.244 :76.646 :: 177:007: - 77.368 77.729 78.09 78.378 78.875 79.373 79.871 80.368 80.38 '81.09 - 81.8 82.51 83.22 83.217 83.947 84.677 85.407 86.137 86.26 7:182 5.937 4:692 3.447 2.201 6.579 5.331 4.082 2.834 1.586 0.13 -1.118 - 2.365 -3.613 ;4.86 3.096 1.579 0.062 -1.456 -2.973 -1.774 -3.29 =4.806 .6.322 -7.839 - -1.842 -3.35 -4.859 -6.367 -7.876 0.744 : ::. -3.729 . 5.221 -6.713 0.271 -1.198 -2.667 -4.136 -5.605 - 5.429 4.009 2.589 . 1.169 -0251 0.816 -0.599 -2.014 -3.428 -4.843 - 23.003 - 31.406 - 38.214 - 43.427 47.045 - 47.045 - 54.643 - 60.649 - 65.061 - 67.881 • - 67.881 =67.25 -65.025 61.208 :. -55.797 - 55.797 - 59.424 - 60.696 - 59.615 - 56.179 56.179 52246 45,959 • - 37.317 26.319 - 26.319 - 22.253 - 15.824 -7.033 4.122 - - 4.122 '6.498.: :. :11255. T :. .18.391 ...:..: 27.906 27.906 28.665 31.828 37.394 45.365 45.365 • . 37:188 31.471 28.216 '27.421 27.421 27.232 29.51 34.256 41.469 41.469 1.486 RISA -2D Version 5.1 [C :Visa \Srolcl.r2d] + Snow, (continued) Shear (K) Moment (K -ft) .,,. ;5 March 30, 2001 2:08 PM Checked By: Page 13 z z cL 2 J U. 00. w= w 0 . (0 d = • W z �. 1-0' Z �- 2 � • 0, 0 O 1-- Ww H 0 .z :. Lb co z 2 - 87.107 . 0.105 0 40:023 3 87.953 -1.276 0.221 • 41.088 4 ....88.8 -2.657 2508.929 44.663 5 89.646 . =4:038 5 5 ' 1 2 89.422 90.48 7.51 6.198 L 50 37.101 3 91.538 4.886 2 : 26.065 4 92.597 3.574 :r 41119 .:.:: 17.642 5 93.655 2.262 1: 108 11.831 1 .93.594 .. . 4.063 -NC :: : .. 1 2 94.685 .2.763 NC 4.926 2 95.776 •. • 1.462 1929.854 0.653 4 ::. 96.867 0.161. .: .. -0.989 5.. ..:97.958 -1.139 .: .0 M1 1 0 0 NC 2 -0.003 0.221 4093.549 3 -0.006 0.436 2508.929 4 -0.008 0.635 2795.542 5 -0.011 0.809 NC - =0.114 0.801 : :.;:.:NC . 2 : '.:.: 16.. 0.932 :1620:113 3 : :r 41119 .:.:: :.- .• :1.035 :::::::::;1207.814 .- .4::...::' :-0 :121 1: 108 1591:533 .5 - ; : .:= - -4):124.: ; :..:;...1.151: -NC :: : .. M3 1 -0.247 1.131 NC 2 -0.249 1.142 1929.854 3 -0.252 1.128 1512.371 4 -0.254 1.093 2096.347 5 -0.256 1.037 NC . :M4:':: .: • -.1:.: ; :.,:- 0.256 ..; ..1.037 .:- : . : NC 2 ::. .':.:. -0:259 ..:. :; :.:0:964 : :: :. : x:- 2461.719 3 - :.::::: -0.261 = :. :. 0.872 .....: .1825.039 4).263 -: :. 0.763 :... 2386.327 ,. -0.265 ....:.., :. ..0.634 ' : NC M5 1 -0.297 0.62 NC . 2 -0.299 0.473 2026.156 3 -0.301 0.305 1493.387 4 -0.303 0.116 1944.924 5 -0.305 -0.098 NC M6 ' ..:::: "1a .. :. -. - 0.288 :. • . _0.14 -NC`::... : 2 ' : =0.29 -0.367 :. ..276.797 .. 3 ' -0292 -0.614 • 132.551: 4 : -0.294 . ' -0.878 85.149 5:. -0.296 • • .•1.157 61.828 M7 1 -0.14 -1.186 NC 2 -0.142 -1.47 NC Company : CT Engineering P.L.-.C. Designer : Chuck Dinsmore Job Number : 0.1033 Lewis and Clark Bowling Alley Member Section Forces, LC 3 : Dead + Snow, (continued) Member Label Section Axial M19 M20 • K Member Deflections, LC 3 : Dead + Snow In RISA - 2D Version 5.1 [C :lrisa\Srolc1.r2d] Shear (K) Member Label Section x- Translation y- Translation (n) Uy Ratio In Moment ( K -ft ) 512 •1 March 30, 2001 2:08 PM Checked By: ' Page 14 Company : CT Engineering P.L.L.C. Designer : Chuck Dinsmore Job Number : 0.1033 Lewis and Clark Bowling Alley Member Deflections, LC 3 : Dead + Snow, (continued) Member Label Section x- Translation (In y- Translation (In) (n) Uy Ratio March 30, 2001 2:08 PM Checked By: • M8 M9 .-• M10.. M11 :: _.:..M12 M13 T`M14: M15 .M16 M17 3 4 5 1 2 3 4 5 1 • '2 •3 4 1 3 4 5 1 2 3 4 5 3 •.5 1 2 3 4 5 1 2 3 -0.143 -0.145 -0.147 -0.147 - 0.149 -0.151 - 0.153 - 0,155 0.04 0.038 0.036 0.034 0.032 -0.045 - 0.047 - 0.049 -0.051 -0:053 • 0.388 0.385 0.383 0.381 0.379 0.438 • 0.436 0.433- • . -0.429 0.643 0.641 0.638 0.636 0.634 0.756 ;...0.753 : 0.751 .: -0.749 .0.746 . 0.738 0.735 0.732 0.73 0.727 0.553 0.55 0.548 0.545 0.542 0.516 0.513 0.51 -1.759 -2.048 -2.331 -2.331 - 2.603 -2.861 -3.101 -3.322 -3.325 -3.523 -3.695 -3.841 -3.956 • 3 4.041 -4.095 -4 :119 4.116 -4.098 -4.058 -3.979 -3.858 -3.698 -3.691 = : - -3.492 4259 = 2.994 2.704'. _,;- -2.661 -2.349 -2.023 -1.686 -1.344 • .• -1279 `. -0.932 ::. ;0.591 '- 0.257.. 0.063 0.129 0.439 0.726 0.99 1.225 .1:313 : 1.527 1.71 1.866 1:998 2.005 2.115 2.202 NC NC NC NC 2506.295 1773.148 2252.387 .. NC NC 1535.618 1115.907 1449.219 NC _NC . : 1367.046 .: -1039.183: 1410.505 NC NC 1232.309 920.714 1230.995 NC _: NC :: 1548.087 1219.975 1729.408 .. NC 4193.639 3634.653 5922.983 NC • 57.039 76.89 : 117.075..: • 238.995: ..NC: NC 2 908 1603.078 2034.24 NC NC : 1937:525 . 1529.665 2124.444 NC NC 2228 088 1617.898 RISA -2D Version 5.1 [C:lrisalSrolcl.r2d] Page 15 4 74.322 50.873 0.508 2.263 - 74.322 2063.564 0.000 5 0.000 114.695 0.505 2.295 NC 1 . .. 0.335 2.325 NC 2 0.332 2.322 1517:891 3 .. 0.329 2.282 1123.099 0.326 2.203. . 1463.173 5. 0.322 2.083 NC 1 0.052 2.107 NC 2 0.049 1.925 1885.661 3 0.045 1.702 1595.96 4 0.041 1.45 2397.206 5 0.038 1.177 NC 0.015:. ..1.178 NC ... :2 ::.: .. 0.011 0.888 ... :NC :: .. ':.- .•,0.008 . ...0.592 :.'.: :NC 4 0.004 0.296 :. NC 5 .... ::: *0 .; . 0 NC . ... :. N1 74.322 50.873 0.000 • ; ::..::: . .:..:N21 .: , ....... :... - 74.322 63:822. 0.000 Reaction Totals : 0.000 114.695 4 Company : CT Engineering P...L.C. Designer : Chuck Dinsmore Job Number : 0.1033 • Member Deflections, LC 3 : Dead + Snow, (continued) Member Label Section x- Translation y- Translation (n) L/y Ratio M18 M19 Joint Label X Force (K ) (In Reactions, LC 3 : Dead + Snow Center of Gravity Coords (X,1) (Ft) : I 56.885 ( 18.784 I RISA -2D Version 5.1 [C :Visa \Srolcl.r2d1 Lewis and Clark Bowling Alley Y Force (K) In Moment (K -ft) March 30, 2001 2:08 PM Checked By: Page 16 YsLr AiN.M�..1 ;. el, z ,. 00 CO a CO la w I N LL wO J u. Q. = . z �... o z Ci (3 I- W u u- z , U �. � 0 Z £ud n: LC S. DAM.Smw MMMr Mnag Ma+wih dK 4!) CT Engineering P.L.L.C. Chuck Dinsmore 0.1033 Lewis and Clark Bowling Alley April 4, 2001 2:39 PM Srolcl .r2d NOTICEc IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THEQUALITY OF THE DOCUMENT. ACTIVITY NUMBER D01 -197 DATE: 06 -29 -01 PROJECT NAME: STERING REALTY ORGANIZATION CO. L &C BOWL SITE ADDRESS:15820 TUKWILA INTERNAT. BLV.SUITE NO: X Original Plan Submittal. Response to Incomplete Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued DEPARTMENTS: Building Division AWL 0 -je'( Public Work PLAN REVIEW /ROUTING SLIP ts< 51D Fire Prevention AWL - 6 - 0 1 Structural 5 -a-4 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1 Incomplete Plan ing Division 1-3.0( Permit Coordinator t'1 • DUE DATE: 07-03-01 Not Applicable n Comments: TUES /THURS ROUT G: Please Route Structural Review Required pi No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved Approved V'NROUII.foC srn Approved with Conditions REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved with Conditions REVIEWER'S INITIALS: DUE DATE 07 -31 -01 n Not Approved (attach comments) DATE: DUE DATE Not Approved (attach comments) DATE: silt .'kCfw^. DEPARTMENTS: Building Division Public Works Complete TUES /THURS ROUTI Please Route REVIEWER'S INITIALS: Approved VIROUILDOC srri PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER D01 -197 DATE: 06 -29 -01 ,. PROJECT NAME: STERING REALTY ORGANIZATION CO. L &C BOWL SITE ADDRESS:15820 TUKWILA INTERNAT. BLV.SUITE NO: X Original Plan Submittal Response to Correction Letter # Revision # AFTER Permit Is Issued Response to Incomplete Letter # DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Comments: CORRECTION DETERMINATION: Fire Prevention Structural Incomplete n Structural Rgew Required APPROVALS OR CORRECTIONS: (ten days) Approved with conditions REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 07 -03-01 Not Applicable n r ev. tes 01 No further Review Required n DATE: 7 - 3 - Zo0 DUE DATE 07 -31-01 Not Approved (attach omments) DATE: DUE DATE Approved Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: } :sz <ws`4: 0'44 t "....S:i s < ,aGk.aairwti:� : ,i'&�,t6 'tvl t�l34.6 • tilhaVaV PERMIT NO.: Vbt l q BUTLITENG't''ERMITS INSPECTIONS ❑ 00001 Progress Inspection Status ❑ 00002 Pre - construction ❑ 00003 Investigation ❑ 00004 OK to Occupy ❑ 00005 Remove Stop Work Order ❑ 00006 Follow -up ❑ 00007 Pre -Move Inspection ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation/Indoor AQC ❑ 00070 NLEA Inspection/Ivlpdular Struct ❑ 00071 Mobile Home Tie Down Insp ❑ 00072 Marriage Lines ❑ 00090 Rested ❑ 00095 Footing Drains ❑ 00100 Foundation Footings ❑ 00200 Foundation Walls ❑ 00250 Foundation Insulation ❑ 00300 Concrete Slab /Slab Insulation ❑ 00350 Crawl Space ❑ 00400 Shear Wall Nailing ❑ 00450 Plywood Wall Sheathing ❑ 00500 Roof Sheathing Nailing ❑ 00525 Plywood Deck Nailing ❑ 00550 Exterior Wall Sheathing ❑ 00600 Masonry Chimney 00610 Chimney Installation /All Types 00700 Framing ❑ 00750 Roof /Ceiling Insulation ❑ 00800 Floor Insulation ❑ 00801 Wall Insulation ❑ 00802 Exterior Roof Insulation ❑ 00803 Glazing Inspection ❑ 00815 Lighting and Controls ❑ 00900 Suspended Ceiling ❑ 01000 Interior Wallboard Fastening ❑ 01001 Exterior Wallboard Fastening ❑ 01 1 10 Pre -Move Inspection ❑ 01 1 15 Motor Inspection ❑ 01120 Pre -Demo ❑ 01140 Pre- reroof ❑,91400 Final -Fire 01700 Final - Building ❑ 01900 Final - Reroof ❑ 03100 Site Visit ❑ 04000 Special- Concrete ❑ 04001 Special -Bolts in Concrete ❑ 04001 Special - Mom/Resist Cone Frame ❑ JI4003 Special -Reinf Steel Prestress 4004 Special - Welding ❑ 04005 Special- High- Strength Bolting ❑ 04006 Special - Structural Masonry ❑ 04007 Special - Reinf Gypsum Concrete ❑ 04008 Special- Insulating Cone Fill ❑ 04009 Special -Spray Fireproofing ❑ 04010 Special- Piling, Piers, Caissons ❑ 04011 Special - Shotcrete ❑ 04012 Special- Grading, Excav/Fill ❑ 04013 Special - Retaining Wall ❑ 04014 Special - Panels ❑ 04015 Special -Smoke Control System TENANT NANfE: en ► , . A l Of' . C . (L DeLA CONDITIONS 0001 No changes to plans unless approved by Bldg Div 010 Special inspection required, notify Bldg Div 0011 Special inspector shall submit final signed report ❑ 0012 New ceiling grid & light fixture shall meet lateral bracing ❑ 0013 Partition walls attached to ceiling grid ❑ 0014 Readily accessible access to roof mounted equipment ❑ 0015 Engineered truss drawings & caics shall be on site ❑ 0016 Exposed insulation backing material ❑ 0017 Subgrade preparation including drainage, excavation ❑ 0018 Statement from roofing contractor verifying fire retardant class of roof Y 0019 All construction to be done in conformance w /approved plans ❑ "No work shall be done in addition to those modifications..." ❑ 0002 Plumbing permits shall be obtained through King Co ❑ 0020 Structural observation shall be provided for this project ❑ 0021 All food preparation establishments must have King Co ❑ 0033 Fire retardant treated wood shall have flame spread of ❑ 0023 Notify Building Division prior to placing any concrete O 0024 All spray applied fireproofing shall be special inspected ❑ 0025 All wood to remain in placed concrete shall be treated ❑ 0026 All structural masonry shall be special inspected 0027 Validity of Permit ❑ 0028 Rack storage requires separate permit 0003 Electrical permits obtained through L & I ❑ 0030 No occupancy of building until final insp by Bldg Div ❑ 0032 Remove all weeds, concrete, stone foundations, flat concrete ❑ 0036 Manufacturers installation instructions required on site ❑ "BTU maximum allowed per 1997 WA State Energy Code" ❑ 0035 Contact PW Div to obtain insp for water /sewer connect ❑ 0038 A C of 0 will be required for this permit ❑ 0039 Final approval for all TI w /in the limits of the SC Mall ❑ 0004 All mechanical work shall be under separate permit ❑ 0040 All construction noise to be in compliance with 8.2 TMC ❑ 0041 Ventilation is required for all new rooms & spaces 0005 All permits, insp records & approved plans available ❑ 0006 All structural concrete shall be special inspected ❑ "Applicant shall obtain a separate plumbing permit from King Co" ❑ "Anchoring — All new construct and substantial improvement shall be anchored to prevent flotation" 0007 All structural welding shall be done by WABO certified inspector ❑ 0008 All high - strength bolting shall be special inspected ❑ 0009 Bolts installed in concrete shall be special inspected ❑ 0031 Comply with requirements of TlvMC 16.04 ❑ 0034 Removal of septic tanks require approval and compliance with King Co Health Dept. ❑ "Obtain required inspections from appropriate water & sewer districts" ❑ "Fuel burning appliances ❑ "Appliances, which generate...." ❑ "Water heater shall be anchored...." ❑ "Reroot" Plan Reviewer: Permit Tech: Date: Date: <4. urc. sr . s4St.:iFtsN: !xs',?i�74A� } ;ia;a�,�• ;,w'k*:'::� tiara, N,oiu3: is eF3� DEPARTMENTS: Building Division Public Works n PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER D01 -197 DATE: 06 -29 -01 PROJECT NAME: STERING REALTY ORGANIZATION CO. L &C BOWL SITE ADDRESS:15820 TUKWILA INTERNAT. BLV.SUITE NO: X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Incomplete n Not Applicable Comments: TUES /THURS ROUTING: Please Route n Structural Review Required n No further Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved REVIEWER'S INITIALS: .51 CORRECTION DETERMINATION: Approved WKROUILOOC srrI Fire Prevention ® Planning Division REVIEWER'S INITIALS: Permit Coordinator n DUE DATE: 07-03-01 DUE DATE 07 -31 -01 Approved with Conditions Not Approved (attach comments) DATE: /C C' I Approved with Conditions Not Approved (attach comments) DATE: DUE DATE DATE: tit 1W∎sa 4 , .Itltt`a, . S 1iYi 3 ?., 1 4:t � ,t ` « . ° a:t{,LZ•�L •i � ait • .t e ;4 t4t,axM ACTIVITY NUMBER D01 -197 DATE: 06 -29 -01 PROJECT NAME: STERING REALTY ORGANIZATION CO. L &C BOWL SITE ADDRESS:15820 TUKWILA INTERNAT. BLV.SUITE NO: X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued DEPARTMENTS: Building Division Public Works Complete Comments: Approved WRROIIIC.000 SPYI PLAN REVIEW /ROUTING SLIP Fl Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES /THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved with Conditions n n Planning Division Permit Coordinator • n DUE DATE: 07-03-01 Incomplete ri Not Applicable No further Review Required DATE: (0 DUE DATE 07-31 -01 REVIEWER'S INITIALS: DATE: Not Approved (attach comments) ri CORRECTION DETERMINATION: DUE DATE Approved Approved with Conditions ri Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: >;•ti v +, -'J si ?ut 424a.t?1,44 tiitau�uy aG f "e iJ E c,'�u Jm%h�ki E'}rt &e ACTIVITY NUMBER D01 -197 DATE: 06 -29 -01 PROJECT NAME: STERING REALTY ORGANIZATION CO. L &C BOWL SITE ADDRESS:15820 TUKWILA INTERNAT. BLV.SUITE NO: X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # AFTER Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUES /THURS ROUTING: Please Route REVIEWER'S INITIAL APPROVALS OR CORRECTIONS: (ten days) 5199 n • PLAN REVIEW /ROUTING SLIP Structural Review Required Fire Prevention n Planning Division Structural Incomplete Permit Coordinator DUE DATE: 07-03 -01 Not Applicable No further Review Required DATE: O4..oa -0 DUE DATE 07- 31-01 Comments: Approved Pi Approved with Conditions n Not Approved (attach comments) REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: Approved Approved with Conditions n REVIEWER'S INITIALS: d DUE DATE Not Approved (attach comments) DATE: ,Y. GT1O ROSENAU & AS.,OCIATES, INC. 30 October 2001 City of Tukwila Building Division 6200 Southcenter Blvd. Tukwila, Washington 98188 Project: Lewis & Clark Bowl Address: 15820 Tukwila International Blvd. We state that the work requiring special inspection was, to the best of our knowledge, in conformance with the approved plans and specifications and the applicable workmanship provision of the building code. Our knowledge is limited to the contents of our handwritten reports. All typewritten reports have been mailed to your office or are enclosed. All reports appear to be complete. This report should not be considered as a warranty for conditions and/or details of the building. Items inspected are: JLP /jp 1. Structural steel erection/welds Sincerely, OTTO ROSENAU & ASSOCIATES, INC. i. nne L. P Corporate Officer cc: Sterling Reality Organization fax c: Chinn Construction Geotechnical Engineering, Construction Inspection & Materials Testing 6747 M. L. King Way South, Seattle, Washington 98118 -3216 USA Tel: (206) 725 -4600 • Toll Free: (888) OTTO -4 -US • Fax: (206) 723 -2221 WBE W2F5913684 • WABO Registered Agency • A2LA Accredited Laboratory • Website: www.ottorosenau.com RECEIVED OCT 3 1 2001 COMMUNITY DEVELOPMENT Permit Number :4P0.1 4 Job Number: 01 -663 x Owner x Contractor Architect x Building Dept. Engineer Report Number: 001 Inspection(s) Performed: Structural Steel Erection/Welds Inspector and Date Copies to: Form No.: T -104 Revised: 02/01 0'. CO ROSENAU & ASLJCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing 6747 M. L. King Way South, Seattle, Washington 98118 -3216 USA Tel: (206) 725 -4600 • Toll Free: (888) OTTO -4 -US • Fax: (206) 723 -2221 WBE W2F5913684 • WABO Registered Agency • A2LA Accredited Laboratory • 1lEeEfIr rocom CONSTRUCTION INSPECTION REPORT R �/ � l�.i Project Lewis & Clark— Bowl Permit Number: ,; 1--!,01.3.P. ; Address: 15820 Tukwila International Blvd., Tukwila Job Number: 01-663 Client Sterling Reality Organization Architect Contractor. Sterling Reality Organization Engineer: Remarks D. Graham On site to perform special inspection on field welding per AWS D1.1, AISC and approved drawings. 10 -29-01 1. Verified building permit and approved drawings. 2. Verified welder WABO Certifications: Alan Paris, exp. 10 -1 -02, #PAR- 80- 3339B, SMAW, all position. 3. Performed visual weld inspection on Glulam arch seat per revision CT -5 on arches #6, 8 and 9; south side of building. Welds and workmanship were found to be in conformance. Reviewed by: OCT 31? OOMMUNr "' IDEVELOPML „° CT Engineering This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Page 1 of 1 rt 6 00 ; CO at ILI J H W 0 g J' I a :. I- Z F. 0 , Z U � 0 � U. ~O 111 Z . 52 I O . Z October 30, 2001 PLLC City of Tukwila Department of Commercial Development 6300 Southcenter Blvd. Tukwila, WA 98188 Do/ Attn: Dave Larson Building Inspector Re: Lewis and Clark Bowl — Repair of Glued Laminated Arches Dear Dave, JAN 0 4 200 coil/144w - CT Engineering PLLC designed the repairs to the Lewis and Clark Bowl located at 15820 International Boulevard in Tukwila. The glued laminated arches suffered from decay to the point that the structure was in jeopardy. The unique nature of this project required our close contact with the contractor as the work progressed and the full extent of the decay became known. At your request we provided Structural Observation as defined in Section 1702 of the Code. We have visited the project at the significant structural stages and at completion of the structural system. We have visually observed the structural system for conformance to the approved plans. Observed deficiencies have been reported to the owner's representative, the building official and the contractor in the form of Bulletins. More specifically, we examined the extent of removal of the decayed portion of the wood and assisted the contractor with designs for additional temporary shoring once it became clear that some of the arch sections were significantly more decayed than our initial survey indicated. We approved the epoxy materials used in the repair and periodically witnessed the installation of the borate preservative rods in the wood portions that remained. The concrete masonry beneath the glued laminated arches does not support the weight of the arch and we approved the additional removal so as to permit installation of new arch segments. We designed custom purlin connections that avoided the need to remove the roof membrane. Inspection of the limited amount of welding was inspected by the Special Inspector. We have examined the completed structural system and in our opinion all observed and reported deficiencies have been resolved to the best of our knowledge. Please call me if there are any questions with respect to this letter. Sincerely, Richard E. yble PE Structural Engineers t•-•:41 � _ 0c30 ( 01 CXF E5 7/2W3 180 Nickerson St. Suite 302 Seattle, WA 98109 (206)285 -4512 Fax: 285 -0618 E N G I N E E R I N G re ,AA 2062850618 CT ENGINEERING PLLC October 30, 2001 PLLC City of Tukwila Department of Commercial Development 8300 Southcenter Blvd. Tukwila, WA 98188 Attn: Dave Larson Building Inspector Re: Lewis and Clark Bowl — Repair of Glued Laminated Arches Dear Dave, 271 P02 OCT 30 '01 16:36 CT Engineering PLLC designed the repairs to the Lewis and Clark Bowl located at 15820 International Boulevard in Tukwila. The glued laminated arches suffered from decay to the point that the structure was in jeopardy. The unique nature of this project required our close contact with the contractor as the work progressed and the full extent of the decay became known. At your request we provided Structural Observation as defined in Section 1702 of the Code, We have visited the project at the significant structural stages and at completion of the structural system. We have visually observed the structural system for conformance to the approved plans. Observed deficiencies have been reported to the owners representative, the building official and the contractor in the form of Bulletins. More specifically, we examined the extent of removal of the decayed portion of the wood and assisted the contractor with designs for additional temporary shoring once it became clear that some of the arch sections were significantly more decayed than our initial survey indicated. We approved the epoxy materials used in the repair and periodically witnessed the installation of the borate preservative rods in the wood portions that remained. The concrete masonry beneath the glued laminated arches does not support the weight of the arch and we approved the additional removal so as to permit installation of new arch segments. We designed custom purlin connections that avoided the need to remove the roof membrane. Inspection of the limited amount of welding was inspected by the Special Inspector. We have examined the completed structural system and in our opinion all observed and reported deficiencies have been resolved to the best of our knowledge. Please call me if there are any questions with respect to this letter. Sincerely, Richard E. Structural Engineers ble PE ■ RECEIVED ED NOV 15 2001 BUILDING DEPARTMENT 165Z err `` '�- " • i 0 `3 0 1 01 EXPIRES 7 /21/03 180 Nickerson St. Suite 302 Seattle, WA 98109 (206)285 -4512 Fax: 285-0618 C T L N G I N 1. L R I N G Date: Project Name: Subject: Owner Approval by: Distribution: Kevin Chinn f (425) 898 -0885 Chinn Construction, LLC PO Box 2137 Redmond, WA 98073 -2137 Issued by: Rick Wyble Structural Engineers 2062850618 CT ENGINEERING PLLC PLLC BULLETIN September 26, 2001 Number: CT -2 Lewis and Clark Bowling Alley Repair Summary Response - Site Visit 9/24 and 9/25 Jason Horning f (425) 455 - 8165 Sterling Realty Organization 600 106' Ave. NE Suite 200,..■ Bellevue, WA 98009 -1725 271 P03 OCT 30 '01 16:37 180 Nickerson St Suite 302 Beattie, WA 98109 (206) 285.4512(V) (206) 285-0618(F) Protect #: 01051 Attached: CT2.1, 2.2 Page 1 of 4 The following questions, observations and recommendations were discussed with the Contractor during site visits this week as the full extent of the decayed wood was discovered: ♦ At Arches No. 1 and 4 the amount of decayed material requires that these two arches be supported immediately by scaffolding at the hinge and with a fabricated steel shore per Bulletin CT1 (same as what we're doing at Arches 6 and 8). These arch ends will require additional reinforcing per sketch CT2.1. The steel PL % x 11 is incorporated into this detail and required top and bottom. ♦ At Arch 9 (east end wall) additional decay was observed in the middle of the beam penetrating almost to the inside of the building. The concern is that the wind columns will not effectively transfer their shear to the roof diaphragm. We recommend "kickers" be installed to connect the top of the steel posts to the roof per CT2.2. In addition, verify that the wood in Arch 9 is free of decay and capable of transmitting vertical bearing load to the column. If this is not the case, remove the decayed portions one column at a time and replace with epoxy material. ♦ At Arch 9, a new GL arch segment is to be fabricated and installed per details pertaining to Arches 6 and 8. Shoring is not required provided the wind column bearing points are free of decay or repaired with epoxy filler. ♦ The new arch sections to be installed at Arches 6, 8 and 9 are to be fitted with Impel rods per typical details and flashed for protection from weather and sunlight. (cont'd) Date: September 26, 2001 W.A.i(?k;bM !VtLxe..r..t.r rvkar,.rS% 2062850618 CT ENGINEERING PLLC 271 PO4 OCT 30 '01 16:37 Date: September 26 2001 Number: CT -2 Project #: 01051 Project Name: Lewis and Clark Bowling Alley Repair Attached: CT2.1, 2.2 Subject: Summary Response - Site Visit 9/24 and 9/25 Page 2 of 4 Z _ w . Q: 2 _J O 0 ♦ All exterior arch portions are to be flashed for protection from weather and sunlight. In addition, N w all areas of built -up epoxy are to be painted with System 3 LPU Topside Paint for further UV w protection. N u. w o .. LL ? w . z � o zF- ♦ If the roof purlins must be cut to permit construction access for installing new arch segments 2 w (Arches 6 and 8), cut only as little as necessary, It's feasible to design a saddle type n o' connection that would reconnect the shortened purlins, but it will need to be installed from -- -- above. It may be simpler and cheaper to sister another purlin adjacent to the exisitng and ° ~ connect to the two adjacent arches the same way the existing purlins are connected. 0 ♦ Installation of the Impel rods may stop as close as practical to the exterior face of the CMU wall z provided no new decayed portions are discovered there. ♦ Where the arches are close to a CMU wall parallel to the arch, the Impel rods may be drilled from one side only, drilling per recommendations on sheet S3. ♦ Portions of the CMU wall may be removed directly below the arch if necessary for construction access. Replace in kind. Biucbunai Engineers C T F N C I N P rj Lea l S ALP kr r PlOitrt:. 2062850618 CT ENGINEERING PLLC 271 P05 OCT 30 '01 16:38 Structural and Civil (Engineers - Date. Client sp,° Page Number: 150 Mc/croon St. Suite 302 Seattle, WA 98109 (20G),28S -4512 FAX: (206) 28$.0618 CS) Ft5 Structural end Civil Engineers 2062850618 CT ENGINEERING PLLC C T � Protect: L 6 f SIQD Clie it: St _ SX 1 CPc StDE c2JA -1 Kf (3' �$ 271 P06 OCT 30 '01 16:38 Date: 91 Page Number:. ~ J G I C I 160 Nickerson S. Suite 302 Seattle, WA 98109 (206) 2.85-4312 FAX: (206) 283-0618 • Issued by: Rick Wyble CT E N G : rJ E E R I N G Owner Approval by: Distribution: Kevin Chinn f (425) 898 -0885 Chinn Construction, LLC PO Box 2137 Redmond, WA 98073 -2137 Structure' Engineers 2062850618 CT ENGINEERING PLLC PLLC BULLETIN 4. I 271 P07 OCT 30 '01 16:39 180 N'ICkason St. Suite 302 Seattle, WA 98109 (206) 285-4512(V) (206)285.0618(F) Date: Se tember 10 2001 Number: CT -1 Project #: 01051 Project Name: Lewis and Clark Bowling Alley Repair Attached: CT!.1 Subject: Shoring Post at Glued Laminated Arch Drawings affected: Description /Action: Where a portion of the glued laminated arch is to be removed and replaced, the shoring post may now be installed vertically as shown on the attached sketch. The shoring occurs on one end of the three -hinge arch and assumes that the center hinge of the arch is supported at the same time. Additional stabilizing cables and other supports may be required depending on the sequence of construction and other conditions that will arise in the course of construction. Please call with any questions. Jason Horning f (425) 455-8165 Sterlin, Realty Organization 600 106th Ave, NE Suite 200 Bellevue, WA 98009 -1725 Date: September 10, 2001 Date: ; 2062850618 T ENGINEERING PLLC L fr" C T 1111.131. Project' Client: U 14w 4. 1 1 I structural and Civil Engineers 0 Date: u 271 P08 Page Number L— 4 \1L- it=u3 • , 0 OCT 30 '01 16 : 39 Suite 302 Seattle, WA 96109 12061 2054512 TAX: (206) 286416113 \ # 7 TI 4 4 CUL', KiTT7-::4 (FoLL -( k. f tkkizr-;H; f.'LeCtiv\ \?..)LLous3 2 I 74, 06C, WI 1)) I i)-tr. 2062850618 CT ENGINEERING PLLC CT E N G I N E E R I N G Date: Project Name: Subject: Revised Knee Brace Detail — Arch 9 October 9, 2001 Number:CT -3 The knee brace detail shown in Bulletin CT -2 (Sht. CT2.2) is to be revised as shown: Structural Engineers Issued by: Rick Wyble Owner Approval by: Distribution: Kevin Chinn f (425) 898.0885 Chinn Construction, LLC PO Box 2137 Redmond, WA 98073 -2137 PLLC BULLETIN Lewis and Clark. Bowling Alley Repair I Jason Homing f (425) 455 -8165 Sterling Realty Organization 600 106 Ave. NE Suite 200 Bellevue, WA 98009 -1725 271 P09 OCT 30 '01 16:40 Project #: 01051 Attached: none CZ') A fJ Date: 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512(V) (206) 285-0618(F) g (v ON l= SI De c Uj 0(11-1 lSi arJ Date: October 9, 2001 r, �e.«± s.: ?p•• � ..vei�ntay...�:i�t. i'� >. structural Engineers 2062850618 CT ENGINEERING PLLC E N G I N E E R I N G Date: October 24, 2001 Number; CT -5 Project #: 01051 Project Name: Lewis and Clark Bowling Alley Repair Attached: none Subject: Repair Detail for GL Arch Seat Issuadby: Rick Wyble Owner Approval by: Distribution: Kevin Chinn f (425) 898.088 Chinn Construction, LLC PO Box 2137 Redmond, WA 98073 -2137 PLLC BULLETIN 271 P10 OCT 30 '01 16:40 The steel connector for the GL arch connection may be repaired as shown where the upper restraint tab was removed to facilitate installation of the new. GL arch segment 180 Nidcason 8 . 8uile 302 Scottie, WA 98109 (206) 285- 4512(V) (206) 285.0618(F) Date: October 24, 2001 Date: Jason Horsing f (425) 455-8165J Sterling Realty Organization 600 106 Ave. NE Suite 200 Bellevue, WA 91t009 -1725 2062850618 CT ENGINEERING PLLC CT E N G I N E E R I N G Date: October 17, 2001 Project Name: Lewis and Subject: Splice Detail for Purlin Next to Exterio!A of Structural EngjIneera Up to 16" of the existing puffins may be removed to permit access for GL arch segment installation. Install 6x12 segment as shown and reconnect to GL arch. Issued by: Rick Wyble Owner Approval by: Distribution: Kevin Chinn f (425) 898 -0885 Chinn Construct° T.LC PO Box 2137 Redmond, WA98073 -2137 PLLC BULLETIN Number: CT-4 ark Bowling Alley EXPIRES 7/27ja Jason Horning f(425) 455 -8165 Sterlin Organization 600 106 Ave. NE Suite 200 Bellevue, WA 98009 -1725 271 P11 OCT 30 '01 16:41 Attached: none Project #: 01051 180 Nickerson S1. Sine 302 ..- Sable, WA 98109 (206) 285.4512(V) (206) 285.0618(F) Date: October 17, 2001 Date: z 6 JU 00 co WI N u- W 0 J N W H =, Z �. zo p ' o • � W W H U U. 0 ` Lli Z z C ■ EN G l N F E R I N G Date: Project Name: Subject: Up to 16" of the existing purlins may be removed to permit access for GL arch segment installation, Install 6x12 segment as shown and reconnect to GL arch. Issued by: Rick Wyble Owner Approval by: Distribution: Kevin Chinn f (425) 898 -0885 Chinn Construction, LLC PO Box 2137 Redmond,, WA 98073 -2137 Structural Engineers 2062850618 CT ENGINEERING PLLC PLLC BULLETIN October 17, 2001 Number: CT-4 Lewis and Clark Bowling Alley Repair Splice Detail for Purlin Next to Exterior wall Jason Horning f (425) 455 -8165 Sterling Real O 600106' Ave. NE Suite 200 Bellevue, WA 98009 -1725 271 P12 OCT 30 '01 16:41 Project #: 01051 Attached: none 180 Nickerson St, Suite 302 Settle, WA 98109 (206) 285- 4512(V) (206) 285.0618(E) Date: October 17, 2001 Date: x Owner x ' Contractor Architect x Building Dept. Engineer 10/30/2001 16:56 2067232221 OTTO ROSENAU ASSOCSS PAGE 01/01 0 110 ROSENAU & ASSOCIATES INC Geotechnical Engineering, Construction Inspection & Materials Testing 6747 M. L. King Way South, Seattle, Washington 98118 -3216 USA Tel: (206) 725.4600 • Toll Free: (888) OTTO -4 -US • Fax: (206) 723-2221 WBE W2F5913684 • WABO Registered Agency • A2LA Accredited Laboratory • Website: www.ottorosenau.com CONSTRUCTION INSPECTION REPORT Report'Number: 001 Inspedtlen(s) Performed; Structural Steer ErectlonNWeids Project Lewis & Clark — Bowl Permit Number: D 01197 Address: 15820 Tukwila International Blvd., Tukwila Job Number. 01-663 Client Sterling Reality Organization Architect Contractor: Sterling Reality Organization Engineer. CT Engineering Inspector and Date Coples to This report applies only to the items tested or reported and Is the exclkslyo, p operty of Otto Roeenau a Asaooiatea, Inc. Reproduction of this report, except In full, wlthout.wrltten permission from our firm is strictly prohibited.' Page 1 of 1 Form No,: T -104 Revised: 02/01 Remarks On site to perform special inspection on field welding per AWS D1.1, AISC and approved drawings. 1. Verified building permit and approved drawings. 2. Verified welder WABO Certifications: Alan Paris, exp. 10 -1 -02, *PAR -80- 33398, SMAW, all position. 3. Performed visual weld inspection on Glulam arch seat per revision CT-5 on arches #6, 8 and 9; south side of building. Welds and workmanship were found to be in conformance. Reviewed by: OTTO ROSENAU ASSOCSS PAGE 02/02 OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing 6747 M. L. King Way South, Seattle, Washington 98115 -3218 USA Tel: (206) 725 -4600 • Toll Free: (888) OTTO-4-US • Fax: (206) 723 -2221 WBE W2F5913884 • WABO Registered Agency • A2LA Accredited Laboratory • Website: www.ottorosenau.com 10/30/2001 17:00 2067233R 30 October 2001 City of Tukwila Building Division 6200 Southcenter Blvd. Tukwila, Washington 98188 Project: Lewis & Clark Bowl Permit Number: DO1 -197 Address: 15820 Tukwila International Blvd. Job Number: 01-663 We state that the work requiring special inspection was, to the best of our knowledge, in conformance with the approved plans and specifications and the applicable workmanship provision of the building code. Our knowledge is limited to the contents of our handwritten reports. All typewritten reports have been mailed to your office or are enclosed. All reports appear to be complete. This report should not be considered as a warranty for conditions and/or details of the building. Items inspected are: JLP /jp L Structural steel erection/welds Sincerely, ROSENAU & ASSOCIATES, INC. v Jane L. ParvW Corporate Officer cc: Sterling Reality Organization fax c: Claim Construction • May 6, 2002 Jason Horning 600 106th Avenue NE Bellevue, WA 98004 RE: Permit Application No. D01 -197 15820 Tukwila International Boulevard Dear Permit Holder: Guy of Tukwila Based on the above, you are hereby advised to: Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. • Call the City Of Tukwila Permit Center at (206) 431 -3670 to schedule a progress / final inspection A progress inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -time extension up to 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection or request and receive an extension prior to June 25, 2002, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Stefania Spencer Permit Technician Xc: Permit File No. D01 - 197 Bob Benedicto, Building Official Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 431 - 3665 Reid iddleton Dear Mr. Griffin: Sincerely, Reid Middleton, Inc. Kali . Yam . tsuka, P.E. Proje t Manager August 8, 2001 File No. 26 -01- 005- 012 -01 Mr. Duane Griffin City of Tukwila 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ■�A+r 'ra CY. va t t.�,t - ice x s . w AUG C; 9 2001 COMMUNITY DEVELOPMENT Subject: Building Permit Plan Review - First Submittal Sterling Realty Organization — Lewis & Clark Bowling Alley (D01 -197) We reviewed the proposed project for compliance with the structural provisions of the 1997 Edition of the Uniform Building Code as amended and adopted by the City of Tukwila. There are no comments pertaining to this submittal. Enclosed are the drawings, structural calculations, and correspondence from the engineer for your records. If you have any questions or require any additional clarification, please call. Adina Prisecaru Project Engineer bjr\ 26se\ planrevw \tukwila \01 \t012r1.doc \ap cc: Jason Horning, SRO Washington Chuck Dinsmore, CT Engineering Oregon Alaska Engineers Planners Surveyors Reid Middleton, Inc. 728 134th Street SW Suite 200 Everett, WA 98204 Ph: 425 741 -3800 Fax: 425 741 -3900 July 19, 2001 Dave Swanson, P.E. Reid Middleton 728 - 134th Street SW, Suite 200 Everett, WA 98204 Sincerely, Brenda Holt, - Permit Coordinator City of Tukwila Steven Al. Mullet, Mayor Department of Community Development Steve Lancaster, Director Structural Review Sterling Realty Organization — L & C Bowl — (DO1 -197) Dear Mr. Swanson: Please review the enclosed plans and documents for structural compliance with the 1997 Uniform Building Code. If you should have any questions, please feel free to contact me at (206)431 -3672. Permit File No. D01 -197 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 Sent By: CHINN Construction, LLC; '• 0.7 4258980885; •4 XuldNICI PUV 1 1 36 0C1 Aug-16-01 10:57AM; • . t • "' " , • . • • .• • taiiii)SOUraft09.d ••'• • •: •••:. • •• ••••••• ' • •• ••••• '" • •• • . 4 .. , ., • • , • .• : : E65.Z ORE' ciNowami .. • • . . • .. • • . .. .. s , — • •• • ' - ' •• ': '''.":: DrIrf - NO IILDflUI'Sg0P1;rttsiIHD ' " ..... : - . ' ": '-' : : •-.: •• ' ' ' . ••., . .. . • ..." i ' . r •• " . ' '' • • ' ' ' .. •Ir " ' ' ‘8 ' l : ., ' ". •;.' . . , • • •• ., • 1 , . . • • • • • , .1 ': `44''.1 c . . . . ... . .. . .1) • . , . 4 ‘!?1,,:all tfi',..NC7flifr' t944Itti '' ri, . . • • ' • • • ' '0 ; . ' fr' ' ,MItili; • .; 1 i.` '''Sf kr :, * " t.r.1..P.1; ,' • '• •• • ' • : ..• ; ... •. ; ,, ,• • t .. . . . • • . • . , . .• " ..f..•`; A .44:4,{Exii. • fp , ;t21'. • ,, ' ...'• •,. . . , • :•••• • • . 4 1ViND 1NAD. ...LoNC50' • , • . • , • ;AI .. .caul/011a casuals ioaa 4 .• ":' • • ' 's • k ■ . • , . • •• * • " • * SaralSrk \II (INV • UbiTVI 40: 3 " • ..• • .6. Page 2/2 COMMENTS: Se614,2 Lt.l Cka L.AbACi wi. I . iF w �Q c \c lo,Y,Ps 1 OigSte )1 _AM F C,5 rRINIO rd o t 1 +61Y -e 0, •Pvv`1 -- c\vj 1 \Jckcc4 t t1 q pre tnn \ Se .c . S)Vuv\ A 'Dean i u-f - 9 3 l0 1 o ()u)v,. r 0 lu t lCii l In h e r. \ ck ercc-kr- a5 G ) \or\hc -Co r 2 9I1) —LfrV urk eetwx.5 , 0 6 J Yle r \ - ca vat 1 I a;01 2, Cl►,S SS 4- .r-e, o- c- Ipui tcit r) Phone: Prpject: , t 1--u 4 C.14$4. �2W ^� d=0U-A ■ n Type of Inspection: avwe,0,- ; -;t Address: Y Date called: � Special instructions: Date wanted: p. m. Requester: Phone: INSPECTION NO. 0 Approved per applicable codes. INSPECTION RECC ) Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Corrections required prior to approval. Inspector: n n '?.4 Wir Date: 3- IS-0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. MEMO FOR RECORD DATE: 5/24/01 FROM: Duane Griffin, Bldg Offl Subject: Lewis & Clark Bowling Alley I talked to Jason Horning, 425- 455 -8169, Property Manager, on 5/22/01 regarding the status of the building. He said the bowling alley is moving out immediately and the owner of the property isn't sure what they are going to do yet. Jason said they were talking to their insurance company to see if they could get insurance on the building. He said there is a possibility they might demolish the building, depending on what the insurance company says, and some other factors. I told him that I was calling to make sure that the building was going to remain vacant until engineered repairs have been permitted and completed. He said he understood that. He said that they have had an engineer evaluate the damage and the engineer had thinks the glu -lamb arch beam, shown on the attached picture that is damaged at the top, can possibly be repaired by routing out the damage and filling with epoxy. Horning said the engineer said that the structure was originally overbuilt structurally and he doesn't think there is danger of immediate collapse. I will follow up in about 45 days to see if anything has been resolved. I talked to Steve Kohler, Fire Marshal, this date, about this subject and he said the fire dept is aware of this situation and they have the building classified as one not to enter in case of fire. ;..:... a1 .u.i..:�iaw.iie...lapk;JiLd::.: i':,,3afii��. if . , ..f4a; ' c m1 �T Q w Plan and Notes Emeregen Repair of Lewis and Clark Bowling Alley 15820 Tukwila International Boulevard Seattle, Washington .� NO. REVISION DATE i 4.•\ o T 2 GR/F F Ec, f A sy 6 � ' l v : ar, ' •. � � ' } ' SjORAL 4 �' 0 y CT E N G INEERING PLLO Structural Engineers 180 Nickerson Street Suite 302 Seattle, WA 98100 209,296,4612 (V) 209 286,0619 (0) .__._....._..._, PEWIT Si0g111TAL 4/5/01 ENG R : CD ICAD: DWH IPLOT:4/5 /01 ! 0105151 JOB I4: 0,051 _ I EXPIRES. 7/27/2001 1 Dl v 6 0 fffl ) .J IN w r U. a 30 2F N g 9 1 ! i 0 I qil ::b 2 t p_ d i OgijJ wgq �� E li 9 OaP!•'� D D 0 0 2, P yrtli i i q k a Rh g g 2 F_ CA) pi Pi CO .p. _ >_ v i qme 41 P pig ki p i. p 01 19 t1 Ro 'PM" TYPICAL SPACING I I" gguA imE tl ilg ID 4 AO O h iP PP i2; A g O g � gg NI B Si 1 mil 8.WW r •�'.� ;11 Xg 1 � � 1 2 A MOT 7 4 1 1 t`!1°00ri ! 2 00Vdti dqi' ggtg XC 6 g10 0 6 I g 4 2 TYPICAL SPACING CO 2 CO 3 1 F CID rai aTP 0 g w solo N 0 a 0 I I[ O = W E CONCRETE SPANDREL G L / rJ ® r -- - -- NOTE: ADD LAYERS FOR REMOVE AND REPLACE EXISTING KERF TAPER TO MATCH BAOKPLATES ON p�ST ARCH EXISTING ARCH BSS THAT HAVE DETERIORATED MORE THAN 307E OF ORIGINAL THICKNESS. (3) EXIST THRU BOLTS REMOVE EXISTING PAINT AND PREPARE FOR NEW WELD TO BACKPLATE. EPDXY MATCH SIZE 4 SPACING FILL ROTTED AREAS PRIOR TO REINSTALLING KERF PLATES, THRU r BOLTS s, ,gplp WASHERS. _ E 3/6 X II SacKPLATE r = , I II x V4' SEE SEE ELEVATIONS FOR LOCATIONS (2) V2' DIA LAG SCREWS I t WASHERS W/ 6' EMBEDMENT + 12' 0.C. STAGGERED I ATION I '- -E<IST. GLULAM AH 1 1 GAL V_ SHEET MET CLIPS FOR AIR I GARY SHEET METAL C.OVERMG DRIP BY OTHER8 p - • � / I� 1 PROVIDE FOR GALV. METAL FLASHING IN EXIST. REGRET I I I 1 i - -- I I ' 6' V3/I6 f EXT CMU WALL I I, r 4 ! ! EXIUSTL _ 1 I - _ 6' P36' ` O S. NIL.- \ EXIEXISTING s BEAIPY.s PLATE - $ REMOVE EXIST. PAINT AN PP F WELD j TO W ' , EXISTING ANCHOR BOLTS TO REMAIN SCALE= 314• • 1' -0' SCALE: 1' • 1' -ID' ( a I I 1 CORES SOLID GLULdM ARCH REPLACE 8XBX8 BUT CMU AS REQ. - ' I TYPICAL TYPICAL FROVIDE FOR 111111 DETAIL GARY METAL FLAWING AROUND O PENING TYPICAL -- -r 111 — 11 1T. _. ________ LIMIT OF R9'10YAL f 4 PLATE DETAIL S S C. EXIST. REGRET — i( t - `� XI EXISTING ESTING qyJ WALL THRUST BLOCK � Z — f NOTE: CMU REPAIR 18 ONLY NECE8SARY F REMOVAL IS REQUIRED TO ALLOW CL REMOVING NEW G4LV. METAL FLASHING BY OTHERS EXIST. NAILER I \ GL ULAM ARCH I I , I i I I I \ GLUT.. ' I \ ! 9 NOTE RE: DE 1, 2, 6 & 7 FLASHING AND WATERPROOFING DETAILS EHOLLt4 HERE ARE SCHEMATIC kWfffJMp R CONTRACTOR G CONSULTANT TO S. AND TO TAKE PER DESIGN. — � 9 — + -1 iv 9 \ n III L GLULAM ARCH 8. -6. SCALE: 1 V2' • I' -0' f SCALP: 1' • 1' -0 • SCALE: V2' . 1'-0' 2 HEAD FLASHING DETAIL 3 I FLASHING DETAIL 5 THRUST BLOCK PLAN STYROFOAM CG ARCH REMOVE EXIST. ROOFING AS RECL REROOF WHEN CONSTRUCTION IS IS COMPLETED 1' DIA BOLTS TS C6) UIINII AND WASHERS (4) PLACES � - S/S X 24' X 4' -8' EACH SIDE �/ ` o o /\ EXIST. REIhF. f CONCRETE SPANDREL ECT ASSEMBLY Mi SPANDREL EXIST. NAILER REPLACE Ii X 301/8 GLULAM SECTION .6 AND IS ^ _ ..,,,- •.,:,,,. 1 .. FILLER __416A NEW GALV. METAL AND SEALANT EXIST. CMU FLASHING BY OTHERS ■ I ADD ADDITIONAL \ LAYERS TO MATCH EXIST. TAPER \ CONK KEODPLATE p REVIEWED AUG - 8 2001 o S' o (3)1' DIA BOLTS o W/ NUTS 3 9LASFiERB le o l° � - _� DISCON REMOVE EXIST. 3/4' DIA. LAG SCREWS REID MIDDLETON, INC. EACH SIDE T Sr SHORE EXIST. GLULAM ARCH UNTIL NEW SECTION IS �� REPLACED t CONNECTED O 0 o �.. o o i f 4) ` ■ o \ \ \ ' ' _ STEEL BASE PLATE 4 ANCHOR PLATE 5-8 V4• C IFt ) ;4J.El JAMB FLASHING DETAIL q O � C((„_ o o T i i • + R` . %.. 40 � i6T ' "7 , 1 + � / B " rT' SHORE EXIST. FtURLIN EA SIDE OF ARCH. WALL ���I EXIST. MALIN EXIST. CH U WALL \ N V fo .0 REMOVE HANGER CONNECTION. \ \ N GS _ `i ^t l'? v 22 9 , i GLULAM ARCH I I I I I EXIST. ELEV. FIN. FLOOR • 35L92 -- VIAL BACKER ROD NEW GALV. METAL FLASHING OTHERS 7' P T (VERIFY) AND SEALANT EXIST. CMU EXIST. CONCRETE STEM WALL -6'3 (VERIFY) f -2' EXIST. -4' PAVING EXIST. CONCRETE THRUST BLOCK ANCHOR EXIST. CMU REMOVE SIDES • BOTTOM NOTE: AS REQ. FOR ARCH REMOVAL COORDINATE MECHANICAL �1 AND ELECTRICAL EXISTING CONDITIONS. SCALE: 3/4' • I'-0' SCALE= V2' • 1' -0' BY SCALE= I I/2' • I' -0' 7 SILL FLASHING DETAIL 8 SECTION 9 I THRUST BLOCK ELEVATION 0 a 0 I I[ O = W 1E II' X1 /4' EXIST. CONC. (2) 1/2' DIA LAG EXIST. CGNC. fe II' XI/4' IE II' XI/ (2 � 181+'3 EXIST. =NC. (2) I/2' DIA LAG R$ , � Ile; / . .� � 164'3 EXIST. CONC. EXIST. SPANDREL SCREWS WASHERS b'EMBED REMOVE DETERIORATED WITI4 EPO AND FILL 194'3 SPANDREL • S REWS WASHERS REMOVE DETERIORATED MATERIAL AND FILL j I 1� �� // I 194'3 SPANDR • REMOVE DETERIORATED MATERIAL AND FILL / 1 i , % 194'3 SPANDREL DETERIORATED �'`V' - • • �SGREWS REMOVE DETERIORATED MATERIAL AND FILL WITH EPDXY REMOVE MATERIAL AND FILL J �• D 4 INSTALL • • • IMPEL TYPICAL s \ '4 DRILL 4 INSTALL f► IMPEL RODS \\ TYPICAL • • • • WITH EPDXY v 42 DRILL 4 INSTALL T-\ ��_ IMPEL RODS • I \ TYPICAL WITH E PDXY • • • DRILL 4 • IMPEL S '� . r '0001,.... i . � .:Ii T GMU EXIST. EXIST 18•30 DRILL 1 INSTALL S • ErAI P. NONE • �/ ' . • • , 9 , 1A 1B • ■ t ^ i w EXIST. GMU WALL L EXIST iDC30 1/8 GLULAM �P :D •. • • • • , 9 , - EXIST. Ci 6J WALL 2A � ' • ' . • • •, ' • 9 ° 3A IXIST. CMU WALL / A / _ EXIST IIX30 1/g Rio AM �- i • .TYPICAL _` ° m 9 . ° 4A 4B WALL l/8 GLULAM DF • - ° \ ® s , 5A EXIST CMU WALL EXIST 1800 1/8 CsLULAM� EXIST ITX30 1/8 GLULAM ry P SCALE- NONE m „ ) P SCALE: NONE b SCALE: NONE 4 SCALE: NONE 1 ARCH NO. 1 DETAILS 22 ARCH NO. 2 DETAILS 3 ARCH NO. 3 DETAILS . �^y ARCH NO. 4 DETAILS 5 ARCH NO. 5 DETAILS EXIST CONC. EXIST. CONC. SPANDREL I ° -.1..." ! % EXIST. C IU WALL SA � I 6B EXIST. CONG - .i • DR ILL 4 It�TALL IMPEL RODS TYPICAL r , • . • • , 9. • • EXIST. GMU WALL 1D (301 /8 GLULA SPANDREL %�i �Y ', j gt' 4. �� i G i • EXIST. CMU WALL EXIST 11X30 1/8 GLULAM 8A I 8B EXIST 11X30 1/8 GLULAM SCALE: NONE ----,11- EXIST SCALE: NONE_ i; SCALE: NONE ARCH NO. 6 DETAILS 7 ARCH NO. 7 DETAILS 8 ARCH NO. 8 DETAILS 10 NOT USED 11 NOT USED �- Ci 7 I I , iir I p i II �` I� 1943 � j 4 . / i 4 / I � i I / �� 1/2' TREATED PLYWOOD _ i APPLY 11 2'12' TREA YWOOD I�LL L � EXTERIOR SIDE AS FORM FOR EPDXY ; :;; $ i w REMAIN FOR R� Sum PAINT P TYPICAL PLYWOOD AS DESIRED. TYPICAL 9E 9C �y I CI I �� ' , ,I' I ' �j I� O e, 9A 9B 9D ����i.'O: / , Ar ' / / / /// /'///// 9F ,, ..�� a , � / �ii� „����� ° MULLI W/ CAP PLATES IN GOOD DRILL AND INSTALL _ • ' . • 6' �� // - .•.• ' 9 SEE NOTES ••.•• 12 NOT USED ... -. ` - .... , OP. DRILL AND INSTALL IMPEL I FROM SURFACE. APPLY 12'T TREATED . • • • ��. 9'C” StN ICAL • FOR EPDXY ' y� • SEE NOTES FI LLER BOTHSIIDES .. 12' TREATED PLYWOOD � TOP AND BOTTOM WHEN EPDXY FILLER CURES AND HARDENS /� I • ' . ' • EXIST IM AM 30 1/S GLUL, �• ''� M REMOVE Dc'TEI 1ORAIED �t.TERIAL ST EEL COLUMNS ' WOOD TYPICAL APPLY I/2 TREATED PLY ' ' EXTERIOR SIDE AS FORM FOR EPDXY TO // y 14 FILLER THROUGHOUT PLYWOOD (INSIDE) REMAIN FOR VISIBLE SURFACE PAINT PLYWOOD AS DESIRED. TYPICAL �: S " z tC ` E r _� ) r _ EXIST. GMU WALL GLULAM ARCH INSPECTION BY 82S 2ND STREET SUITE E MUKILTEO, WASHINGTON 98215 KINGSLEY DRAM PE. (425) 3-48-0511 1n 1 1 ,H,ET 5 n SCALE: NONE '° I 9 ARCH NO 9 DETAILS 113 NOT USED