Loading...
HomeMy WebLinkAboutPermit D01-259 - DEFENSE CONTRACT AUDIT AGENCY - IMPROVEMENTSDEFENSE CONTRACT AUDIT AGENCY 14240 INTERURBAN AV S D01 -259 City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Parcel No: 336590-1881 Address: 14240 INTERURBAN AV S Suite No: Location: Category: AOFF Type: DEVPERM Zoning: C /LI Const Ty.pe: Gas /Elec.: Units: 001 Setbacks: North: Water: N/A Wetlands: Contractor License No: MMISEI *094P5 OCCUPANT OWNER CONTACT Permit Center Authorized Signature: Signature: Print Name: WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. DEVELOPMENT PERMIT .0 South: .0 Sewer: N/A Slopes: Y Occupancy: OFFICE UBC: 1997 Fire Protection: SPRINKLERS East: .0 West: .0 Permit No: Status: Issued: Expires: Streams: (206) 431 -3670 DEFENSE CONTRACT AUDIT AGENCY Phone: 14240 INTERURBAN. AV S, SUITE 216, TUKW FAIRWAY CENTER ASSOCIATES C/O HALLISSEY RJ CO INC, 12835 BEL -RED RD, #140, BELLEVUE WA 980 LEE SHEPHARD Phone: 425 -455 -9292 12835 BEL -RED RD, BELLEVUE, WA 98005 CONTRACTOR M M I SERVICES INC Phone: 425 - 369 -8655 245 EAST SUNSET WAY, I'SSAQUAH, WA 98027 ***** *** * *•k• kit•**** * ** CIF *•k* ** c******************* * **•*•k * **k** ** * * *•k * ****k* *** Permit Description: TENANT IMPROVEMENTS TO EXISTING OFFICE SPACE, APPROX. 5835 SQ. FT. NEW NON -LOAD BEARING WALLS, METAL STUD PARTITIONS, WOOD DOORS, FLOOR AND WALL FINISHINGS. k * * * * * *k ** * * * **** kph ** ** *7Fic•k•k•k7h** *** * *•k ** *: * ** kph* * *•k•k•k*** * * ** * *k *** *•k•k•k*** ******** Construction Valuation: $ • 85,000.00 PUBLIC WORKS' PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut %Access /Sidewalk /CSS: N Fire Loop Hydrant: N • No: Flood Control Zone: N Hauling: N Start Time: Land Altering: N Cut: Landscape Irrigation: N Moving'Oversized Load: N Start Time: Sanitary Side Sewer: N DO1 -259 ISSUED 09/14/2001 03/13/2002 Size(in): .00 End Time: Fill: End Time: No: Sewer Main Extension: N Private: N Public: N Storm. Drainage: N Street Use: N Water Main Extension: N Private: N Public: N **** k****** ************************* k**** k***** k* A** * * *k * * * * * * * * * *** * * * **•k **kk** ** TOTAL DEVELOPMENT PERMIT FEES: $ 1,470.94 ******************• kk********Ak**** k****• k• k: kk*k k* k** kkkk *k•k * * * ** *** *A** * * * * * * * *k * *•k* � Date: Q/ J hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. Date: 72 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. ...y.� , r. -...., v...s�- .,- ..._.. _ .. ... .........:...y....,. 4a:.,.... J::.rA�aJiiw'.:..a.Ldc..:s:.'p: w: ..,..,��,.......�...u.i..�dro:. v.,, .++:... Address 14240 INTERURBAN AV S • CITY OF TUKWILA Permit No: D01-259 Status: ISSUED • Applied: 08/20/2001 Issued: 09/14/2001 Type: DEVPERM • Parcel :#: 336590-1881 Permit Conditions: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. Any new ceiling grid :and 1 ighe.fixture installation is 0required to meet lateral bracing requirements for Seismic Zone 3 Partition walls attached to ceiling grid must ;braced if,:Vve'r eight (8) feet in length. 1A11 con to'be done in conformance with approved . .plans and'requirements of the Uniform Building Code (1997 as%amended, Uniform , Mechanical Code (1997 Edition), : and Washington State Energy 'Code (1997 Edition); 5. PluOjna,permits shallj3e Obtained through the Seattle-King •• County Department of,PUblic Health. Plumbing'will be ' iry.spectedThy that agency, including all gas piping (256-4722). 0 6 - V' i'dit Of Permit. Yhe issuance of ,a permit or approval of pOns, specificat4ons,'and computations shall not be con- 4,41 to be alermit dr'an',appi of, any violatIon, 64 the. - provisions Of the building code or of any , Other or,diriance, of the jurisdiction. No permit presuming to Tive authority'to:violate or cancel the provisions of this 661e shall be vafid, 7 Electrical permits 'shall be obtained through the Washington' , State /Division of Labor and Industries and all electrical wdrwilt be Inspected by that agency (248-6630). 8. Allpermjts, inspection records, and Approved plans shall be aya;11able at the job site prior to the start of any con-' str6C,t,ion. These, documents are to be maintained and avail- -, ableuntil final inspection approval is granted. .***FIREJDEPARTMENT CONDITIONS*** . The attached set of plans have been reviewed by The 'Fire PreventiOn'f3urea6 and are ,acceptable with the following concerns: The total n6mber,of fire extinguishers required for your • establishment'isCalculated.at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, ibB:C) dry chemical 'type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3-1.1) 12. Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. • The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. ) 13. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher", with an arrow pointing to the unit. (NFPA 10, 106.3) (UFC Standard 10-1) 14. Clear access 'to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1-6.5) S. Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 43, 4-4 and 4-4.3) Every six •years, dry chemical and halon type fire ;extinguishers shall,be. to the applicable recharWproOedures. (NFPA If the required monthlyand yearly inspections.offire • . extinguisher(s) are not accomplished orthe inspection tag is not complete , a reputable fire extinguisher service company ,Will be ,required t conduct these required s'urveys. (NFPA A0; 4 4-4) 16. Maintain fire extinguisher'cOverage throughout 17, No point in an unsprinklerpd building may be more than 200 feet from an exit measured along the path of travel (UBC 1004 5 2 1) 'Nof?Opintin a sprinklered building may be more than 250 feet Froitian exit, measured along the path of travel. (LW 1,00.4.25.2.2) Exit doors shall-sWing the direction of exit travel when 12°) • serving OrlY,hazardouS or when serving an occupant load , , 4:7! 50, - , 9r:Imore ,- ; '(UBC 1003:3. I . 20. Exit doors ,shall be openable from the. Inside without the se of "a key or any/Special, knowledge or Exit doors shall not be 'locked 'chained, 'bolted, barred, latched.. orotherwise rendered unusable, All 16Cking devices shall', IpPlof an approved type. (UFC 1207.3) ,. not allowed on aux.:11Iary exit „ • ••,••.,, .„ • , .• • ..,:•!„ • dead the lakitomaticallYretracted when the door handIe Is engaged from insideithe tenant space. (UFC • -., • _ „ 22. WhentWo orvmore exits from e story are required exit. , signsshall bi'installed at the required exits and where otherwise necessary , to cl early indicate the direction of egress. (UBC 1003.2.8.2) . When two or more exits from a story are required and when two or more exits from a room 'or an area are required, exit signs shall be illuminated (UBC 1003.2.8.4) 24. Internally illuminated ,exit signs shall have both bulbs working at all times'. (UBC 1003.2.8.4) 2 . Exits shall be illuminated any time the building is occupied with light having an intensity of not less than 1 foot candle at floor level. Fixtures required for exit illumination shall be supplied from separate sources of power for Group I, Division 1.1 and 1.2 occupancies and for all other occupancies where the exiting system serves an occupant load of 100 or more. (UBC 1003.2.9, 1003.2.9.2) 26. The power'supply for means of egress illumination shall normally be provided by the premises electrical supply. • In the event of its failure, illumination be 1,4.4,4AIXt'aLtab‘So.Aktik . ,t4.41 z z w 6 00 (0 0 C/) W —I I u j g u_ < a I— ILI Z I— 0 Z I— W LIJ • co O — • I— I 0 L I 0 co O F. automatically provided from an emergency system for Group I, Divisions 1.1nd 1.2 occupancies and foenll other occupancies where che means of egress system ,.erves an occupant load of 100 or more. Such emergency systems shall be installed in accordance with the electrical code. (UBC 1003.9.2) . All exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 1 1/2 hours in case of primary power loss, the exit signs shall also be connected to an emergency electrical system provided •from storage batteries, unit equipment or An on site generator set, and the system shall be installed In accordance with the electrical code. (UBC 1003.2.8.5) . ilaintian sprinkler coverage per N,F,P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/§r adding sprinkler heads. . Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13-4-5.5.3,4) . All new,Sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval'of-drawings'priorto :installation or modification. New,•sO'rinkler systems and all modifications to sprinkler sys.temS involving more than 50 heads shall have the written apOckralof the W.S.R.B.,'Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated ancVor?recorgnized by the City of Tukwila, prior to submiVtal,:to:the Tukwfla Fire Prevention Bureau. No Winkler work shall commence without approved drawings. , Ordinance #1.901) 0 Sprinkler system Plans, Calculations and the 311:59tracors, Materials and Test Certificates submitted to tye TukWila-Fire-Preventton:,Bureau must be stamped with the aporopriatelevel Of,competency,seal. (WAC 212-80) Maintain foot coverage of detectors per ! manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls closets' or partitions may , A require relocating and/or adding automatic fire detectors; . r‘ 72, 5=4-.4.2)- All neWjire:alarm systems or modifications to existing systemS-,:shall'have the Written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department .permit has been obtained. (City Ordinance 41900) (UFC,1001.3) 5. All electrical work,and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 36 An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110-16(a), NEC 110-16(c)) 37. Each circuit breaker shall be legibly marked to indicate its purpose. (NEC 110-22) 38. Required fire resistive construction, including occupancy ,separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof LA4ksj:Le..4);:::.:4,1aa'AA4141:14,,,a, ',.;;A1. ..auiip.;t1.4::444ke,,e4.ortiIttY=e1k,f4 W.;io_44V,kkc'iavisA-JaJ.4t,A91.4t4SA4xijVafta4444ivaAa,YAic,ao,li..4fr.4Wt z z L I 6 = O 0 Iw w w I w 0 g u. a 1- LLI I • 1- 0 Z ui C.) O - O I- LI I 0 0 - O F- 7 ignature: aC e: r''� wzMi»}o,1%fw * <ii:T.«;*`N:4fis'i CP c''tY£� <P9't14+x�za.rwc.� .M.,.. coverings shall be maintained as specified in the Building Code and Fire Code and sha 1 1 be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) . The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of the Uniform Building Code. (UBC 804.1) • Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 901.4.4) = :In order to provide you with the fastest police and fire protection under emergency conditions, please post your ;suite, room or apartment number in a conspicuous place near the main entry door. ( UFC • Fire Department lock boxes ,shal 1 be provided for access to all f ire alarm panels and sprinkler risers The ,appropriate key(()' `for.,, access shall be placed, in the lockbox. Lo:ckbox order forms must be obtained , from the Tukwila. Fire; Deper tment '(City Ordinance #1900). Contact ,..the' Tukwila' Fire Prevention Bureau to 'witness, al required ,,inspecti,ons and`t'ests. '(UFC 10.503) (City `Ordinance #1900 and #1901) Thist.review limited to speculative tenant space only spea,i { a l ; fire permits ma ybe necessary depending on'' detailed ed description of i ntende`d ' use . •AnSQ°Overioaked hazardous condition and /or violation of the ad�bpted 'Fir .or Building Codes does not imply approval such : cond i t ion or , i oa anion • Tie plans were reviewed by 511. ;,If you have any questions 11 cal l the Tukwila 'Fire; Prevention' Bureau at (206)::.575- 440`1., these c ify3. that:,.I = have,�`r�ea�d hese conditions and ."wi 11 com l y p: i th them as outlined All pr`ovisions of law and ordinances, governing his rwork will 'be., compiled with, whether `specified herein or,'ndt tie grarrt,i ng ; o f':Y,tin s permit does not presume - -to „.give ,'aut.hor:i ty, t :o violate or . =' cancel the provisions of ariy Other work or local 1a vs` regula construction or e the performanc, of ''work • 7 Project Name /Tenant: ?.ew,N*t t(Ijpwte -- I 'l Se. Goyt1d *Wirt A alue of Construction: er K Site Address (ir}clu e suite n ember) Ci1v State /Zip: 141-4o to yr H 5 o . 9vt 1,1 to Iuwv(l(w Gulp Mlbk Tax Pcel Number: / Property Owner: , ra'lrW,ty et *soe . �G R.3 . tied!//sS 412. IGtc_ . Phone: C 41- �) 4 �s -9211— Street Adclre4s: r City State /Zip: I Zf3 & - 3 u/R. Quit/8 1I. roc. w4 fA�.f ' Fax II: S 1 s - 1 1 /42 ( J Contractor: Phone: Street Address: City State /Zip: Fax II: Architect: ��� >Y � iA t Phone: C it -) 25' es& a `C Street Address: City State /Zip: 4.T2,2,_ w tb 7 Ave. ef tve97 the 9g7A9 ► Fax #: (4 ) 2c7-'25 Engineer: Phone: Street Address: City State /Zip: Fax #: Contact Person: g,-s. frames 5helott.,vri Phone: Nisi 463 2— Street Address: / ,eGp �, � ,/ - /,1 Zy�g�' ��l /J AL, 1`(�UN�' � . I UC. (.� e - City State/Zip: g 7 Fax # ( : / 1 -) 4 - n .7 v�e t'O Description of work to be dong (please be specific): ietAli hail p i t eitA":r 5' extchAt d SJaka-, 4p14.vi . • S; 8 3s .. — 0 - 1 4-• uv- t / 1 Jou , ttmll s, tog, sehed pa,v irnA U w'J d- s, t' Existing use: LI Retail ❑ Restaurant ❑ Multi - family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel g Office ❑ School /College /University ❑ Other _____ _ w Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital Cl Church ❑ Manufacturing ❑ Motel /Hotel Office ❑ School /College /University ❑ Other Building Square Feet: �p3 OG3 existing No. of Stories: 2- Area of construction (sq ft): -7/ °Z 3S 5.-P, Will there be a change of use? ❑ yes lg no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes . no Existing fire protection features: sprinklers Oautomatic fire alarm ❑ none ❑ other (specify) Will there be storage of flammable /combustible hazardous material in the building? ❑ yes Ano Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUV 'lILA Permit Center 6300 Soothcenter Blvd., Suite 100 Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi- Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. 1180/00 cvperniir.doe APPLICANT REQUEST FOR PUBLIC WORKS SITE /CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut /Access /Sidewalk ❑ Flood Control Zone ❑ Hauling Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp II Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous ❑ Fire Loop /Hydrant (main to vault) #: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: Application taken by: (initials) PLEASE SIGN SACK OF APPLICATION FORM ..;': rftau' aiL':eu.es:e:�l r•■r� Project Number: P ermit Number: DO) 264 A. 3 '0 2; [J1 (,`,:I:. '"—" BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: Print name: Phone: Fax II: Address City /State /Zip APPLICATIONS MUST ilt SUIMITttd WITH THt tOLLOWING: ■ ALL �,S�1'� AMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGIiCTV61 INFER )' ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing/grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries O. Identify location of sensitive area slopes 20"/% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form I -1 -9). Z ~ W JU O 0 CO CO CI W J ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled w L W ❑ El Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of 2 J any hazardous materials; dimensions of proposed tenant space. tL ❑ ❑ Vicinity Map showing location of site I W ▪ = ❑ ID Rack H Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of 1--. O rack. Structural calculations are required for rack storage eight feet and over. 2 W El 171 � Indicate proposed construction of tenant space or addition and walls being demolished D to El El Construction details tL W U ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water 1- O supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. U CO . 71 C71 Washington _ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. Z t — ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 999 Third Avenue, Suite 700, Seattle, WA or call (206) 296-4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect /engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. I NO In) cgmrl,lil.due i* sl kk;kkyF**'kAIt 4:4:AA:1•kt slkAk:tkkk * *k•kAkAkIV 4 'v*k kh•A• r : OF ;`TIJI <f rt. . : RraWai<fIT kk�Fyk t 4: dk t� :tk :k * r k *•kk*k *•Akak.t•kkA *kk*kk•k•k tk:tk�A,kkk:1•} TRANBML.T A tt'mber ^ 891.01213. .r-mo teat: 898.25 09/14i01 11:23 P'av rnerit l�f l�t�d « CHECK Notation: FAIRWAY CT'ft AS SO Tnit; 13 Pe mit No .00.1 -259 Type: .DEVPERM DEVELOPMENT PERMIT f�ar•ce1. `No: ::(3b390-1881 e Ad Tres : 14240 INTERURBAN AV Total Fees: 1: TI'i i f'aiymen 893.25 Total (. L L Pelts: 1 , 470.94 Hal ant.' .00 4 k44* k'**k * *k4•*1lk * * * *4** ** .:ttikk •44*k4 Ak:t *A * **4• * **$c *ik * *•' * Ac' :ount Code.::, Desc r i pti on Amount 000/322.1.00: BUI DTN6 NONRE8 888.75 0 00/3'8'6.904 STATE BUILDING SURCHARGE . 4.5 .. • . „ •. **'**,*, 104 y4*:*.it 46'r OC*.+1. 4t. ic !is :iv * Ir'.4.1c .A * — . . N umber \12b 1016,76 . Awount 377.69 013/ 14.03 MEthqd —: .CHECK - WQtctflJfl FAIRWAY CENTER - In jt.: P€r'in it •11911:.1)01 DEOPE:RM DEVELOPNE:NT. PE.RNIT 336t.390--1881 • • - 147 AV S ' • • Tot;] F es: 466.44 This P ayment .. 477, 69 •Icrta 1 L.L. A iPmts: 577.69 , B al ance: - B811.7t.3 k i c 4,,,,, e*** . A 4 *** , * . *******************************.A**71i,***4*•** ,••• ‘ ' 1)e st i P t ion A m act n t ' • '.CHECK NONRES' 577 •'' ••• • _ . ii;it'N•A,. D308 08/22 •9716 TOTAL 577.69 • .; • . , , • • • , • • ! yi Prttgn • ' ' D f Inspe J. : 1 ' , Ai ....cit Date .. - • . 101 8./ pedal instructions: Date wanted: (0 1 a.m. Requester: RAI Phone: ( 120—' o CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981B 8 Approved per applicable codes. I Corrections required prior to approval. COMMENTS: INSPECTION RECORD Retain a copy with permit TO ( PERMIT NO. (206)431-3670 • $47.00 REINSPE at 6300 Southcen ceipt No: TION FEE REQUIREV. Prior to inspection, fee must be paid er Blvd., Suite 100. aII to schedule reinspection. Date: h ribe i 4t: /'7 ..5 2.es. Typ e of In . t_ Pi / /.s ...-- %Ahi Ay*, Add ess: ' ( ) . . L 1 A 0 , - w . M 4 Date called: / / (7--/ Special instructions: • Date wanted::, a.m. Requester: ---- .. Phon : . . 01966 902a -- 0 ?6 • 3 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 COMMENTS: Ecs n . ect Receipt No: INSPECTION RECORD Retain a copy with permit Okm -/rte !s Date: 7 7F'•L /0•, Gt/A // 8614ph ooRe %11 c- reothe.,2 (1,7 - < %►;�� F rte PERMIT NO. (206)431- 3.670 Approved per applicable codes. Corrections required prior to approval. Date: ,/ _a / $4 .00 REINSPECTION F REQUIRED. /Pj onto inspection, fee must be paid 6300 Southcenter Blvd. Suite 100. Calf to schedule reins•ection. aldr af18i35r�s+h�ii ?D`fiit`ix'�i3- ; Nr:. 4 . li, S�''.±',* �JNa) at{ ssS".. i;+ �Tk: '�'t�},'Y,; w 6 00 No : (nw W IL w • }} g < co c z � Z O. ju o • S2. ;o l- w : H • V ' 0' , z 111 0 0 Proje • T e of Inspe do 1 Li ._Oc tir Ac/... � Date�all�flCT ? lO 1 Special instructions: Date wa Cf a_ rye q f --2)/ O( p.m. Reque t r: Pho5e_, � 16 �1Q� y INSPECTION RECORD Retain a copy with permit.. INSPECTION NO. CITY'OF TUKWILA BUILDING DIVISION: 6300 Southcenter Blvd, #100 Tukwila' WA 98188 COMMENTS: A G(t„) r-t r� veei kss o ni∎ 1iJG I f Over )mil Approved per applicable codes. Inspector: _ 30/1Arr Date: 9 ...,2 8 - 0 I $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: PERMIT NO. • (206)431 =3670 Corrections required prior to approval. .: �rn?R „''(ti �•`: ;a:#tiU':1an :'. ��L "tti %'�/i5diiltZH?2R x +�wb!ii' vsurtI e:U: 4.....$43 ` .H Z. UO: NO t w 0 : �QQ LL W d` H W Z .I- O z 2 ai 'U - ; W W; U- z' U5 . F.. _: 0 z Pr je Q CPI Ty i_Y pectid�: ddr / -khA�C Da c lied: 4 /mfr. Special instructions: Date wa ted ,U/ a.m. p.m. Requ r: ev Phone: 610 %i 0 76, A _.. r. ...tea R-r. RECTION RECORD etain: a copy with permit SPECCION,N OFTUKWILA BUILDING DIVISION ;6300 :Southcenter B vd,. #100, Tukwila, WA 98188 COMMENTS: • Approved per applicable codes. U Corrections required prior to approval. $47.00 INSPECTION FEE QUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: PERMIT NO. (206)431 -3670 1 fr4P444114kgatilg■5731.11A07Wa:347;:i;■.,;+-1,41.31;"4%.r1 '..MT -4 7 " 7.1 Project Name Fire Department Address 142_40 71:1 lc\ 15 Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature F,INALAPP.FRM City of Tukwila John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Permit No Thomas P. Keefe, Fire Chief rY10( ( DOI c7q5 (....0v(4.-Jk A\J&A Suite # (5(5) C lb( Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 • Fax (206) 575 Project Info , Project Address rairway Center Bldg a Date 8/16/01 14240 Int.rurban So. Suit. 216 For Building Department Use Tukwilla, Wa. Applicant Name: C1CIA Architects Applicant Address: 2722 Colby Ave. Suit. 607, 11:v r.tt, Wa Applicant Phone: (425) 259 -1560 1994 Washin ton State Nonresidential Energy Code Corn ' liance Form Climate Zoill 1 Envelope Summar. ENV -SUM 1997 Washington State Nonresidential Energy Code Compliance Forms FILE COPY ier.., fit, f ci tt ^t the P1 n Check approvals are 1 tir;r First Edition - June, 1998 CITY OF RECEIVED • AUG 2 0 2001 PERMIT CENTER Project Info Project Address ?airway center Bldg B Date 8/16/01 Allowed x Area 14240 Interurban So. Suite 216 For Building Department Use 0.2 Wife Tukwilla, Wa. Applicant Name: cNn Architects Applicant Address: 2722 Colby Ave. Suite 607, iverett, Wa Applicant Phone: (425) 259 -1560 Alteration Exceptions (check appropriate box) ❑ No changes are being made to the lighting v Less than 60% of the fixtures are new, and installed lighting wattage is not being increased Location (floor /room no.) Occupancy Description Allowed Watts per ft2 •• Area in ft Allowed x Area Covered Parking 0.2 Wife Open Parking 0.2 W/ft Outdoor Areas 0.2 W/ft ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Covered Parking 0.2 Wife Open Parking 0.2 W/ft Outdoor Areas 0.2 W/ft Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts Location Description Allowed Watts per ft or per If Area in ft (or If for perimeter) Allowed Watts x ft (or x If) Covered Parking 0.2 Wife Open Parking 0.2 W/ft Outdoor Areas 0.2 W/ft Bldg. (by facade) 0.25 W /ft Bldg. (by perim) 7.5 W /If Note: for building exterior, choose either the facade area or the perimeter method, but not both) Total Allowed Watts Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts Lighting Summary LTG -SUM 1997 Washington State Nonresidential Energy Code Compliance Forms 1997 Washington State Nonresidential Energy Code Com.nliance Form First Edition - June, 1998 Project Description I ❑ New Building ❑ Addition Alteration Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Maximum Allowed Lighting Wattage (Interior) nufactuer's listed maximum input wattage. For fixtures wttn naro -wires oanas Proposed Lighting Wattage (Interior) only, the default table in the NREC Technical Reference Manual may also be used. Maximum Allowed Lighting Wattage (Exterior) se mfgr listed maximum input wattage. For fixtures with h d ar-wired oanasts only; me Proposed Lighting Wattage (Exterior) default table In the NREC Technical Reference Manual may also be used. . r..+ F. u< nwrny7rsePT IVORMte:4 4i1MInc: Use' LPA (W /ft Use' LPA (VI//ft Painting, welding, carpentry, machine shops 2.3 Police and fire stations 1.2 Barber shops, beauty shops 2 Atria (atriums) 1 Hotel banquet/conferencetexhibition hat" 2 Assembly spaces ° , auditoriums, gymnasia theaters 1 Laboratories 2 Process plants 1 Aircraft repair hangars 1.5 Restaurants/bars 1 Cafeterias, fast food estabNshments 1.5 Retail A' 1 Factories, workshops, handling areas 1.5 Retail B Retail banking 1.5 Gas stations, auto repair shops 1.5 Locker and /or shower facilities 0.8 • Institutions 1.5 Warehouses ' storage areas 0.5 Utraries 1.5 Aircraft sbrage hangars 0.4 Nursing homes 1.5 Parking garages s.. s«"°' 1532 Wholesale stores (pallet rack shelving) 1.5 MaN concourses 1.4 Plans Submitted for Common Areas Only Schools buildings, school classrooms, day care centers 1.35 Canmon area, corridors, lobbies (except mall concourse) 0.8 Laundries 1.3 Toilet facilities and washrooms 0.8 Office Wirings, officeladministrative areas in facilities of other use types (including but not imited to schools, hospitals, institutions, museums, banks, churches) 1.2 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers Q Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly Indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: ❑ Check here if at least 95% of fixtures in the space meet all four criteria: 1. Fixtures are fluorescent, non - lensed, with only one or two lamps, and 2. Lamps are T -5, T-6, T-8 or PL, and 3. Lamps are 5-50 Watts, and 4. Ballasts are electronic ballasts Lighting Summa sack) LTG-SUM 1997 Washington State Nonresidential Energy Code Compliance Forms 1997 Washington State Nonresidential Energy Code Commliance Form Table 15-1 Unit Lighting Power Allowance (LPA) for Interior Lighting Footnotes for Table 15-1 u,n?n''7V4 3fHvhkW )chv ?w,.t�th First Edition - June, 1998 1. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table Sec Section 1512 for exempt areas. 2. The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3. Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet 4. For all other spaces, such as seating and common areas, use the Unit light Power Allowance for assembly. 5. Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet 6. Includes pump area under canopy. • 7. In cases in which a lighting plan is submitted for only a portion of a floor, a Unit Lighting Power Allowance of 1.35 may be used for usable office floor area and 0.80 watts per square foot shall be used for the common areas, which may include elevator space, lobby area and rest rooms. Common areas, as herein defined do not include mall concourses. 8. For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot 9. For indoor sport tournament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per square foot 10. For both Retail A and Retail B, light for free - standing display, building showcase illumination and display window illumination installed within two feet of the window are exempt. Retail A allows a Unit Lighting Power Allowance of 1.0 watts per square foot. Ceiling mounted adjustable tungsten halogen and HD merchandise display illuminaries are exempt Retail B allows a Unit Lighting Power Allowance of 1.5 watts per square foot, including all ceiling mounted merchandise display luminaries. 11. Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. W. • re 6 00 O I W ' NU. W O gQ N D. = I... Ili Z = I- 0 Z 2 p . U 'O N. c H W u l• u O .. Z. U N; • OI- Z • 1997 Wash'ngton State Nonresidential Energy Code Comp -mince Form Lighting Power Allo .nce Adjustments LTG -LPA 1997 Washington Stale Nonresidential Energy Code Compliance Forms Project Address Fairway Center Bldg B Date 8/16/01 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15-1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft Carry the Adjusted LPA to the corresponding "Allowed Watts per ft location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) ** From Table 15-1 based on exceptions listed in footnotes First Edition - June, 1998 Location (floor /room no.) Occupancy Description Allowed Watts per ft Ceiling Height for this room Ceiling Height limit for this exception ** Adjusted LPA Watts per ft rd L �.t ;st >`,a=17it� re? dr&, u ,ik�1f�w4iSrr+'"L`1Rtlitia� 4117 4mIezf v 6IA44''ki !i4-"',if l-F0,4 y f;It ' J Project Address Fairway Center Bldg B Date 8/16/01 The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the 1994 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yea 1513.1 Local control/access Schedule with type, indicate locations yea . 1513.2 Area controls Maximum limit per switch yea 1513.3 Daylight zone control Schedule with type and features, indicate locations yea vertical glazing Indicate vertical glazing on plans n. a. overhead glazing Indicate overhead glazing on plans n.a. 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location n. a. (a) timer w/backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location no 1513.6.1 (a) occup. sensors Schedule with type and locations no 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans yaa Lighting Sum. Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n.a. I IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I 1997 Wain•ton State Nonresidential Ener• Code Comr -" Form Lighting Permit Pla Checklist 1997 Washington State Nonresidential Energy Code Compliance Forms LTG -C H K First Edition - June, 1998 If "no" is circled for any question, provide explanation: 1513.61 &1513.62: not required per 1132.3. ACTIVITY NUMBER: D01 -259 DATE: 8 -20 -01 PROJECT NAME: Defense Contract Audit Agency SITE ADDRESS: 14240 Interurban Av S SUITE # 216 X Original Plan Submittal Response to Correction Letter # Revision # Response to Incomplete Letter # After Permit Is Issued DEPARTMENTS: Rye Building Division a -1- bl Public Wo ( S DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Approved \PRROUTE.DOC 5/99 TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: (4 weeks) CORRECTION DETERMINATION: Fire P Prig. 13-2, Structural Incomplete ri Comments: Structural Review Required Approved n Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Approved with Conditions I k n REVIEWER'S INITIALS: Plank Division Permit Coordinator DUE DATE: 8-21-01 Not Applicable No further Review Required DUE DATE 9 -18 -01 Ex, DATE: DUE DATE Not Approved (attach comments) DATE: ,tr'iJr:+.0 !:; V) 111 ,: '„.4g:filk. •tsi .4 ' 6 t- ,t .'ii +;utJ! i?.:•; ACTIVITY NUMBER: D01 -259 PROJECT NAME: Defense Contract Audit Agency SITE ADDRESS: 14240 Interurban Av S SUITE # 216 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DATE: 8- 20 -01 Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n Not Applicable Comments: C�►L Lt IJ (.pWI c OV , 7 mx j ID f Fet.6 0 5‘ttr t...5e.A.j • TUES /THURS ROUTING: Please Route Approved REVIEWER'S INITIALS: REVIEWER'S INITIALS: PLAN REVIEW /ROUTING SLIP CORRECTION DETERMINATION: Approved \PRROUTE.DOC 5/99 Fire Prevention Structural Structural Review Required APPROVALS OR CORRECTIONS: (4 weeks) Approved wily SConditions Approved with Conditions REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 8-21-01 No further Review Required DATE: DUE DATE 9 -18 -01 Not Approved (attach comments) DATE: I" 7 - Zoo DUE DATE Not Approved (attach comments) DATE: ; 31,,M, Sie@ tolUi'v40°s�:V4) S' ft�. a ��kinutitY. tib,' fir�x':% � rsi dl rfd?ra,.., :4: �x ,,X ���•k'aa,rr:�u,aa�;»sti�h w ' re 2 00 O W =. a — : NU . w co J u_ I- Z = F- O Z F- LU uj O 0: O N 0 F- w w . I- U P- 0 W Z , o 1- z PERMIT NO.: J/ d i 259 `* BUILDING PERMITS INSPECTIONS ❑ 00001 Progress Inspection Status ❑ 00002 Pre - construction ❑ 00003 Investigation ❑ 00004 OK to Occupy ❑ 00005 Remove Stop Work Order ❑ 00006 Follow -up ❑ 00007 Pre -Move Inspection ❑ 00050 WSEC Residential ❑ 00060 WA Ventilation/Indoor AQC ❑ 00070 NLEA Inspection/lMIodular Struct ❑ 00071 Mobile Home Tie Down Insp ❑ 00072 Marriage Lines ❑ 00090 Resteel ❑ 00095 Footing Drains ❑ 00100 Foundation Footings ❑ 00200 Foundation Walls ❑ 00250 Foundation Insulation ❑ 00300 Concrete Slab /Slab Insulation ❑ 00350 Crawl Space ❑ 00400 Shear Wall Nailing ❑ 00450 Plywood Wall Sheathing ❑ 00500 Roof Sheathing Nailing ❑ 00525 Plywood Deck Nailing ❑ 00550 Exterior Wall Sheathing ❑ 00600 Masonry Chimney 00 610 Chimney Installation/All Types 700 Framing ❑ 00750 Roof /Ceiling Insulation ❑ 00800 Floor Insulation ❑ 00801 Wall Insulation ❑ 00802 Exterior Roof Insulation ❑ 00803 Glazing Inspection ❑ Q0815 Lighting and Controls 0900 Suspended Ceiling 01000 Interior Wallboard Fastening ❑ 01001 Exterior Wallboard Fastening ❑ 01 110 Pre -Move Inspection ❑ 01115 Motor Inspection ❑ 01120 Pre -Demo ❑ 01 140 Pre - reroof ❑ 01400 Final -Fire [01700 Final - Building ❑ 01900 Final - Reroof ❑ 03100 Site Visit ❑ 04000 Special- Concrete ❑ 04001 Special -Bolts in Concrete ❑ 04001 Special - Mom/Resist Conc Frame ❑ 04003 Special -Reinf Steel Prestress ❑ 04004 Special - Welding ❑ 04005 Special- High - Strength Bolting ❑ 04006 Special - Structural Masonry ❑ 04007 Special - Reinf Gypsum Concrete ❑ 04008 Special - Insulating Conc Fill ❑ 04009 Special -Spray Fireproofing ❑ 04010 Special- Piling, Piers, Caissons ❑ 04011 Special - Shotcrete ❑ 04012 Special - Grading, Excav/Fill ❑ 04013 Special - Retaining Wall ❑ 04014 Special - Panels ❑ 04015 Special -Smoke Control System TENANT NAME2 CONDITIONS 2'1001 No changes to plans unless approved by Bldg Div ❑ 0010 Special inspection required, notify Bldg Div ❑ 0011 Special inspector shall submit final signed report 012 New ceiling grid & light fixture shall meet lateral �/ bracing Ldp u 013 Partition walls attached to ceiling grid ❑ 0014 Readily accessible access to roof mounted equipment ❑ 0015 Engineered truss drawings & talcs shall be on site ❑ 0016 Exposed insulation backing material ❑ 0017 Subgrade preparation including drainage, excavation 0 0018 Statement from roofing contractor verifying fire �� retardant class of roof Ud' u 019 All construction to be done in conformance w /approved plans ❑ No work shall be done in addition to those modifications..." 0002 Plumbing permits shall be obtained through King Co ❑ 0020 Structural observation shall be provided for this project ❑ 0021 All food preparation establishments must have King Co ❑ 0022 Fire retardant treated wood shall have flame spread of ❑ 0023 Notify Building Division prior to placing any concrete ❑ 0024 All spray applied fireproofing shall be special inspected ❑ 0025 All wood to remain in placed concrete shall be treated ❑ 0026 All structural masonry shall be special inspected rg4027 Validity of Permit ❑ 0 28 Rack storage requires separate permit 0003 Electrical permits obtained through L & I 0030 No occupancy of building until final insp by Bldg Div 0032 Remove all weeds, concrete, stone foundations, flat concrete ❑ 0036 Manufacturers installation instructions required on site ❑ "BTU maximum allowed per 1997 WA State Energy Code" ❑ 0035 Contact PW Div to obtain insp for water /sewer connect ❑ 0038 A C of 0 will be required for this permit ❑ 0039 Final approval for all TI w /in the limits of the SC Mall ❑ 0004 All mechanical work shall be under separate permit ❑ 0040 All construction noise to be in compliance with 8.2 TMC ❑ fiO41 Ventilation is required for all new rooms & spaces 0005 All permits, insp records & approved plans available ❑ 0006 All structural concrete shall be special inspected ❑ "Applicant shall obtain a separate plumbing permit from King Co" ❑ "Anchoring — All new construct and substantial improvement shall be anchored to prevent flotation" ❑ 0007 All structural welding shall be done by WABO certified inspector ❑ 0008 All high- strength bolting shall be special inspected ❑ 0009 Bolts installed in concrete shall be special inspected p 0031 Comply with requirements of TMC 16.04 ❑ 0034 Removal of septic tanks require approval and compliance with King Co Health Dept. ❑ "Obtain required inspections from appropriate water & sewer districts" ❑ "Fuel burning appliances ❑ "Appliances, which generate...." ❑ "Water heater shall be anchored...." ❑ "Reroot' ° a Plan Reviewer: Permit Tech: 044,044, Date: Date: ! -7 ZOO Date: nk��E:�t �:w.'r,7.i' .d r�aJa"i.'7',1 4a� `'i. Sii Y Vii -`• Fe.takt .44'»'',4, �{ 7�t�M :dF�.+} N+�N Nsf f� ;'1f.CH>�*(+415,k °iS 51) ACTIVITY NUMBER: D01 -259 DATE: 8 -20 -01 PROJECT NAME: Defense Contract Audit Agency SITE ADDRESS: 14240 Interurban Av S SUITE # 216 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: PLAN REVIEW /ROUTING SLIP Structural Structural Review Required APPROVALS OR CORRECTIONS: (4 weeks) Approved REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved \PRROUTE.DOC 5/99 Fire Prevention Approved with Conditions 0 Approved with Conditions Incomplete n Not Applicable n REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 8-21-01 No further Review Required DATE: DUE DATE 9 -18 -01 Not Approved (attach comments) DATE: - DUE DATE Not Approved (attach comments) DATE: 2 ui � D U U J = „_ . w g J- _ a , F .. w :. Z � � Z ~ uj 2 M 0 O - CI /- I0 - w Z U N O Z ACTIVITY NUMBER: D01 -259 DATE: 8 -20 -01 PROJECT NAME: Defense Contract Audit Agency SITE ADDRESS: 14240 Interurban Ay S SUITE # 216 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: Approved \PRROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP I I n Fire Prevention Structural Incomplete Structural Review Required APPROVALS OR CORRECTIONS: (4 weeks) REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 8-21-01 Not Applicable DUE DATE 9 -18 -01 Approved with Conditions n Not Approved (attach comments) [:xt Comments: No further Review Required \� DATE: - ZO — D l DATE: CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: RECEIVED AUG 2 1 2001 PUBLIC WORKS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D01 -259 DATE: 8 -20 -01 PROJECT NAME: Defense Contract Audit Agency SITE ADDRESS: 14240 Interurban Av S SUITE # 216 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works n [54 Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES /THURS ROUTING: 6 ? 9 Please Route Structural Review Required REVIEWER'S INITIALS: Approved \PRROUTE.DOC 5/99 V REVIEWER'S INITIALS: f I Incomplete n Not Applicable APPROVALS OR7ORRECTIONS: (4 weeks) Fire Prevention ri Planning Division Approved with Conditions n Not Approved (attach comments) A S /VI 0 ( CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: DUE DATE: 8-21-01 n No further Review Required DATE: 231211 0( DUE DATE 9 -18 -01 DATE: Permit Coordinator i co . w Jam w O ga . a F Wm �. I- O Z UJ O N, O I- W O `. w Z U = O ~, Z o LICENSE DETAIL INFORMATION Form STATE OF WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES Specialty Compliance Services Division P. O. Box 44000 Olympia, WA 98504 -4000 THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS: LICENSE DETAIL INFORMATION Current Filter: None Registration# or License MMISEI *094P5 Name M M I SERVICES INC Address 245 S SUNSET WAY Address City ISSAQUAH State WA Zip 98027 Phone Number 4258823034 Effective Date 10/25/91 Expiration Date 1/30/02 Registration Status ACTIVE Type CONSTRUCTION CONTRACTOR Entity CORPORATION Specialty Code GENERAL Other Specialties UBI Number 601226635 * * *VIEW PRINCIPAL OWNER(S) FOR THIS LICENSE* * * * **VIEW CONTRACTOR BOND /SAVINGS INFORMATION * * * * "CHECK INQUIRY FOR SUMMONS AND COMPLAINTS* * * * * * VIEW CONTRACTOR INSURANCE INFORMATION * * * https://wws2.wa.gov/lni/bbip/TF2Form.asp?License=MMISEI*094P5 Page 1 of 1 New inquiry by CITY, NAME, PRINCIPAL OWNER NAME, NUMBER, UBI NUMBER or return to the L &I Construction Compliance Home Page 9/14/01 Balance`Due: $ Need Current Contractor Registration Card: Need to Enter. Contractor Information in Sierra: k:: :` • ::•:<•::::: is�:'•: ::+ ;:::;:;;•::; :'•t2 <$:' +.•:�.'•:'' +.S ? +: >:.� �'.•: �:}:;::;••i`> 5::#;$; �:: r::: 5!; �:::;• x•::•; �: �:: �: i' t�; 5�: �:: 3::' t? �5: �: i:%;: c�: Sr` Si: �;::+;:;:::•: t:•}:•: ;:•:;.:;:•:t•:::�•••:• +:'•. +' :r •:�:•..:•• :: :•: +:•: • >:: . t .f.J. : t o .. J��:::t' Cbkt e ' b hs -as -q a a9 �f. i.: �.....:... i ..:.x.?i.`v.;ti�il��,';A;:..�: >s ;��s....., �. , df ;;;�te:;f:l Z W re 6 U : U O C U1 W =; J 1— W O '. g J; Q CO H = .. Z I— O Z I U C) O == 111 LI Z `. LL! ' H = 0 z 145TH 3T 1 T ST 144TH S S 1HL1TH 3T FOSTER GOLF LINKS - GOLF COURSE i Tukdvilaj PROJ CT SITE 14240 INTE �1 E4N so. NORTH a25 259 -:500 .a... a zs zsz -�s9; REGISTERED ARCHITECT SHEET OF 8 DATE 8'20/01 CNJA JOB NO. 0;025 DRAWN CHECKED DEJ SHEET DESIGN TEAM DRAWING INDEX ARCHITECTURAL: CHURCH NICKERSON JANSEN ASSOCIATES 2122 COLBY AVENUE, SUITE 601 EVERETT, WA 55201 425) 259 -1550 1425) 252 -1591 FAX E -MAIL: cnjaarchitectsRaol.com CONTACT: DAN JANSEN SITE PLAN, VICINITY MAp, SCHEDULES, NOTES DEMOLITION PLAN, DEMOLITION NOTES, FLOOR PL '`N REFLECTED CEILING PLAN, FURNITURE PLAN MECHANICAL PLAN, SCHEDULES it DETAILS LEND AND NOTES O_I MOLITION PLANS LIGHTING- AND POWER PLANS SCHEDULES, ONE LINE DIAGRAM PARKING PARKING EXIST. BUILDING / = ARKI N! PARKING EXIST. BUi'_D ING 1 iT FLAN SCALE: I "=60' -0:: / / //1/ % C/ 5 0; MECHANICAL: NOTKIN ENGINEERING, INC. 2501 471-1 AVE., SUITE H2O SEATTLE, WA 98121 (206) 44E-1911 (206) 448 -9455 FAX 'od0Hnotkin.com CONTACT: BRIAN GRIFFITH N PARKING - CONTRACTOR ACCESS j � AR.A OF WORK / ELECTRICAL; NULTZ \ BI-4 2401 NORTH 31ST ST., SUITE 200 TACOMA, WA 95401 (253) 383-3251 (253) 353-3253 FAX E -MAIL: joernard*hultz'ohu.corn CONTACT: JULES BERNARD ENTRANCE � C S. 143RD ST. L% L_ P 1 ( fl ) J \J L J r FINISH SCHEDULE LIBRARY BREAK ROOM HALLWAY 55 O iX O BASE 9 101 CPT 'R R R R 104 VCTj R R R R 105 CPTI, RR RR WAINSCOT r W 3 WALLS w w _ P P P P 8' -I OIO Q CEILING UT a F ACT - P P P 8' -10 "= ACT - - P ! P P P 8' -10 " ACTT - Y 55 a 55 CONFERENCE ROOM 102 CPT :R RiP R P P P 8' -10 "* ACTI - SUPERVISOR OFFICE `I 103 CPT! R R R R - P P P 8' -10 " ACT - LAN. ROOM 106 VCT R R ' R R - P P P P 8 -10 " *- ACT - SUPERVISOR OFFICE "2 I�TCPTR R R P F P ! 0-10 " -- ACTI - SUPERVISOR OFFICE °3 08 CPT! R R R R P P P 8' -10 " ACT - WORK STATION AREA '1 I�SCPTR R I R R P P 8' -10 "- ACT - HALLWAY '2 110 CPT; R R R R - - ! P , P P P 8' -10" ACT: - TELE. ROOM III EXIST. - - 8' -10 "± -ACT - CLOSET 112 EXIST. - - 8' -10 "'_ ACT', - WORT. STATION AREA '2 113 CPT R R R R P P P 0 -10" t ACT - OFFICE 114 VCT' R R R R P P P P6 -10" ACT! - MAIL ROOM 115 VCTI R R I R R P : P P 0-10"± ACT - WORK STATION AREA 5 3 116 CPT IR R • - . - ! - - P P P 0-10'± ACT' - API RECEPTION Ill CPT', - R R R - P P' -10 ACT - WORK STATION AREA 118 CPT' R R I R - P . P P - 5 -10 "i ACT - SUPERVISOR OFFICE '4 119 CPT' R R R R P P - P 0 10 "± ACT. - SUPERVISOR OFFICE 53 120 - CPT' R R ! R R • P a' -ACTI, - BRANCH MANAGER OFFICE 1 2 1 CPT' R R R R - • 8'-10 "' - DOOR SCHEDULE o o N ' Z ix a a a' l N - 0, o Q Z W. < w F AT LL = I FRAME p u• A' 3 0 "x1' -0" I - %" WO NAT - WO NAT - A 3'- 0'x1' -0" I ED NAT - WD NAT - ^ 3'-0':x1' -0" 36" WO NAT - A 3'- 0 "x1' -0" 34" WO NAT - DOOR TYPES WOOD DOOR a FRAME MATCH BUILDING STANDARD TYPE, MATERIAL FINISH A HARDWARE ED NAT - ED NAT - Det-2 A\ I' L_ VICINITY MAP FFN . SCHEDULE LEGEND R - 4" RUBBER BASE (CUT DOWN BASE 'd WINDOW SILL' P - PAINT (ACRYLIC LATEX OVER PREVIOUSLY PAINTED OWE - PRIMER = 2 CCATS 0 /ES NEW GUS) ACT - EXIST. 2x4 SUSPENDED ACOUSTIC TILE CEILING OPT - CARPET '/CT - VINYL COMPOSITION TILE EXIST. - EXIST. FINISH TO REMAIN FILE COPY understand inat the Plan Check approvals are subject to errors and omissions ar J approval of plans does not authorize o . of any adopted code or odo,:nco. Rocoipt of fmn- tractor's aoriti of approe2d F' -., acknowledged. REVISIONS NO CHANGES SHALL BE MACE TO E SCOPE OF WORK WITHOUT PRIDE ROVAL OF TUKWILA BUILDING DIVICIOTS. WE: REVISIONS WILL REQUIRE A NEW PLAN SUB MAL AND MAY INCLUDE ADDITIONAL PLAN REVIEW FEES. &'1, r.11_I may LLb SEPARATE PERMIT R DUiRED FOR: tltl MECHANICAL VI rr FLEt ,Z .AL L U�i G r)1lE1 G AS CITY OF TLIT('.'!RILA BUILDINNG °. x13 0 z Ui a I (7. z ,„, m cc z Z ( a Lu LU w U- CITYSE SHEET TITLE TITLE SHEET DOOR FINISP SCI'EDULE. F os "re rl • FOSTER GOLF LINKS - GOLF COURSE P OJ`ECT SITE :14240 INTE I5:4\N SO. : -: 3. 3RD IT NORTH ST s?,_ R It i 'C G C 'I Church 'Nickerson Jansen • Associates SHEET CHECKED CNJA JOB NO. 0;025 SWEET I OF 8 3(20/0 DESIGN TEAM ARCHITECTURAL: CHURCH NICKERSON JANSEN ASSOCIATES 2122 COLBY AVENUE, SUITE 601 E VERETT, WA 33201 :425)25S-1560 425) 252 -1591 FAX 5- - MOIL: cnjaarchitect;aaolcOe CONTACT: DAN JANSEN DRAWING INDEX SITE FLAN, VICINITY MAP, SCHEDULES, NOTES DEMOLITION PLAN, DEMOLITION NOTES, FLOOR PLAN REFLECTED CEILING PLAN, FURNITURE PLAN MECHANICAL PLAN, SCHEDULES E DETAILS E -. LEGEND AND NOTES E - DEMOLITION PLANS 5-3 LIGHTING AND POWER PLANS 5-4 SCHEDULES, ONE LINE DIAGRAM SITE PLAN • PARKING EXIST. BUIL DING- /' EXIST. BUILDING, eiTE . _4N SCALE !",-60'-0" 0!",-60'-0" \ �I/ PARKING i i / , N; N, 7/, N MECHANICAL: NOTKIN ENGINEERING, INC. 2601 4TH AVE., SUITE 420 SEATTLE, WA 98121 (206) 443 -1911 (206) 41-3 - 3435 FAX odgen tkin.com CONTACT: ORION GRIFFITH /// PARKING NORTH PARKING PARKING - CONTRACTOR ACCESS Ati AREA OF N ELECTRICAL: HULTZ \ BHU 2401 NORTH 31ST 5T., SUITE 200 TACOMA, WA 98401 (253) 383-3251 (253) 383 -3283 FAX E -MAIL: jbernardGhultzbhu.cotn CONTACT, JULES BERNARD ENTRANCE 2 S. 143RD ST. LIBRARY CONFERENCE ROOM SUPERVISOR OFFICE `I BREAK ROOM HALLWAY O BASE a ul N 0 101CPT'R RIR R 104 VCT'I R R R R 105 CPT'; R R RR ot 0 WAINSCOT O Q 0 WALLS O • O Q 11-1 Z : N W P I P P P LLI CEILING UT Q ACT - C P P 8 -10'= ACT - - - P P P P 8 -10" t ACT a Lu 102 CPT R R R R - - P P P 8'-10 " = - ACT - 103 CPT'; R R R P P P 8 '0'= ACT - LAN. ROOM :106 vGT'. R R R - P P P IS' -10'= ACT SUPERVISOR OFFICE °2 101 CPT R R'R R P F P! 8 -10'= A SUPERVISOR OFFICE '3 108 CPT! R R R R P P P 8'-10''- ACT - WORK STATION AREA °I IOE R R R - r P 8 -10 "= ACT - HALLWAY S 110 CPT! RR RR - - - • P P P P 8' -10 "' A TELE. ROOM III EXIST. - - - - H ' - - - 8' -I0"= ACT - CLOSET 112 EXIST. - - 8' -10 "= ACT': - WORK STATION AREA "2 113 CPT' R R R R P 8' -10 "± ACT - OFFICE IIAVCTR R R P P P P 8' -10 "` ACT - MAIL ROOM 115 VCT! R R I R R ACT WORK STATION AREA °3 116 CPT, R R R R P P P 8 -10'= ACT: - AP[ RECEPTION 111 CPT - R R P P ' 8 -10 "- ACT! - WORK STATION AREA "L' 118 CPT R R R P P P - 8' - "± ACT - SUPERVISOR OFFICE °4 119 CPT R R P P - P a' ACT - SUPERVISOR OFFICE 12 CPT: R R ; R R - P 6-10 "= ACT - BRANCH MANAGER OFFICE i 2 1 CPT: R R R R P 8' -10 "= ._ACT' - DOOR SCHEDULE 0 N Q N T D L L, O 4 a N W FL, Q z tY w F FRAME Q 'w UT a W F s CZ ' A 3'- 0 "x0' -0" Fie" ED NAT - ED NAT - A 3'-0"x1' -0" '4" WD NAT - EDNAT - A 3' -0 "x1 -0" I';' WD NAT - ED NAT - 4 ` A 3'- 0^ "x1' -0" P :" ED NAT - ED NAT - DOOR I PES 0 WOOD DOOR E FRAME MATCH BUILDING STANDARD TYPE, MATERIAL FINISH E HARDWARE FINISH SCHEDULE lea zs9 VICINITY MAP riN�St^ SG— EDUL E LEGEND R - 4" RUBBER BASE (CUT DOWN BASE a WINDOW SILL I - PAINT (ACRYLIC LATEX OVER PREVIOUSLY PAINTED GWB - PRIMER E 2 GCA<F C /OF NEW GEE) OCT - EXIST. 2x4 SUSPENDED ACOUSTIC TILE CEILING CPT - CARPET VCT - VINYL COMPOSITION TILE EXIST. - EXIST. FINISH TO REMAIN FILE C%CPY I understand Mat the Plan Check approvals are subject to Ltyrors and omIssions and cpproval of plans does not authorize the viola:Ion of any adopted code or ordint,l f t_r- ipt of con- tractor's ccIpi of prey - -, acknowledged. By Date Permit No. REV&3@ONS NO CHANGES SHALL BE MADE TO E SCOPE OF WORK WITHOUT PRIOR ROVAL OF TUKWILA BUILDING DIVIWIOU. OTE: REVISIONS WILL REQUIRE A NEW PLAN SUBMITTAL AND MAY INCLUDE ADDmONAL PLAN REVIEW FEES. SEPARATE PERMIT Ri :QUiRED FOR: [CELLt: I7 Ai It t It ilaC Ng, GAS CITY OF . 1 - UkliViLA BUILCINO i>✓ 0 z iliJ a co Q LV I- z It3 r i ~ Ui 4 M Cl) Cr cc Z LI3 Z z 0 w � U. W SHEET TITLE TITLE SHEET DOOR E FINISH SCHEDULE k . 7.•= DEMCLT1C,N FLAN F-)1 .2-,N NOTES r ---_—_-- . ff it In --! lf - 11 11: - ff r] - 11 3 ▪ ri = H- 11' LLJ. L1 1 [;1 1IEH L I. , L Ell -1 ,- I REMOVE PARTITION WALL (3 MIL. STUDS W; GU,5 EACT- SIDE) FROM F_OOR TO UNDERSIDE OF SUSPENDEC CEILING „REMOvE Exhs WOOD DOOR FRAME Li REMOVE FAST GLLE DOWN CARPET UBEER B45E . W& 5 I RFMAIN L41 REMOvE EXIST 4`,3 G.LL.se RELTE WOOD !FRAME LT, REMOVE EXIST LC w PARTITION WALL WOOD C4F Fel REMOVE EXIST. BASE CABINET REMO iE EXIST. PLAS. LAM CASNET SIB SOFFIT ABOvE F5liREMOvE EXIST. SHELF ROD 3 IZ 14 I I 1 , , REilOvE EXIST. VINYL COMPOSITION TILE FLOORING RUBBER SASE e WALLS TO REMAIN EREMOVE EXIST. POWER POLE - SEE ELEC. EREMOvE EXIST. WOOD DOOR' ! REMOVE EXIST. 51-FOLDING WOOD DOORS FRAME/TRACK REMOVE PORTION OF EXIST P,ARTITION FOR INSTALLATION. OF NEW CASED OPENING REMOVE EXIST. WALL COVERING - FULL HEIGHT PARTIAL FLOOF FLAN SCALE.: 1 /-0" CONFERENC-E ROOM0.1)0 1102 .14—ITT--- HALLWAY / 1105] , - ---.--- ----, LAN :., . ' oc,r-i i > OFFICE "1 (1) 1 lo 1 - SUPERVISOR BRE-AK - I ROOM UJORK STATION AREA 'I 11031' 1 1 lio_*1 r, , ,L, , 1109,1 , OFFICE 5 1 ..-- !!! 110811! FFICE .2 -' !I 11011 H FLOOR PLAN NOTES 0 EXIST. CLEAN OUT e FLOOR - REPAIR/ATTACH OVER PLATE 0 PROVIDE NEW WOOD CASED OPENING 0 EXIST. FIRE POSE CABINET TO REM.AIN 0 . EX15T. COLUMN Cl OLUM COVER e END OF- G.WEJ WALL 0 PROVIDE NEW PARTITION ABOVE EXIST. PARTITION (FROM TOP OF EXIST. WALL TO UNDE.RSIDE OF ROOF- STRUCTURE ABOVE) 3%" MIL. • STUDS e 24" O.C. W/ , /s" GLUB EACH SIDE WORK STATION AREA, 0 11 1113 1 ,1 L WORK STATION WORK STATION 4R24. 1118 I AREA 0 1% C - F ) Typ! RECEPTION 1 1 111 0 4 SUPERVISOR OFFICE .5 0_11201 I MAIL ROOM '1 1115 1 .1 (,) OPW1NDOLU MULLION PARTITION SUPERVISOR N OFFICE 4 1113 1 !S1 ! 4 BRANCH MGR ■--- OFFICE : 11 2 1_1 (°-) NORTH 0 INFILL EXIST. WALL OPENING. W/ 3 MTL. STUDS e • 0.0. Uj: 0 GWEJ EACH SIDE (vE-RIFY - MATCH EXIST. WALL THICKNESS' 0 NEW PARTITION TO UNDERSIDE OF EXIST. SUSPENDED. CE-'LING - MIL. STUDS e le" 0.C. 0/ 5 /a" 0 E4. SIDE (VERIFY - MATC.P WALL THICKNESS) O2 .00••' 11 59 t, A R 0 11 1 T C Church Nickerson Jansen Associates LL1 01 re/ephone: 425 250-1560 66x: 425 252-7597 39°3 REGISTERED A H T I ss-rIAinaa,e ! ,,,c'ill°,.1' 0 (<D z w w • =' < O I" 0 .fc .4( 2 o ix cc I— cc Z Z z i— ott — Z 0 w ; to z - w u_ LU SHEET TITLE PARTIAL OE-MO FLAN FARTIAL FLOOR P_AN CIT`I DATE 000101 CNJ4 Jo5 No DRAWN 505 01-4ECKED DEJ SHEET A-1 Al-IPPT 1 /1. s i [I L LIC- PARTIAL REFLECTED CEILING, FLAN SCALE: REFLECTED CEILING- °LAN NOTES 0 REMOVE/ALTER = REINSTALL EXIST- SUSPENDED ACOUSTIC CEILING S'S-,TEM AS REQUIRED TO INSTALL NEW PARTITION ABOVE CEILING. O REMOVE/ALTER REINSTALL EXIST SUSPENDED .ACOUSTIC CEILING 5Y STEM F REQUIRED FOR INSTALLATION OF NEW HvAC UNIT SUSPENDED FROM ROOF STRUCTURE AWOvE. T. 2x4 SUSPENDED ACOUSTIC CEILING TEM TY°. ING DIUSER TYP. - SEE MECH. PT:FIXTURE TYP. - SEE ELEC. NORTH LAN ROOM 11061 :yr . is ICU ICE SUPERv! OFFICE "I WORK STATION AREA "2 1 113 1 - R MihaLLU ■ mial° Ion r BREAK ROOM -ft B Q 1111111 PRINTER WORK STATION WORK STATION AREA "4 • AREA "3 1 Hai EP ON Ill SUPERVISOR OFFICE S' 1 Lola Ls 1 I 4' @3ia r L � SUPERVISOR OFFICE "4 in � I I I BRANCH MGR. OFFICE 111211 %-JBRARY k (101/ \, CONFERENCE ROO N \ 11 021 PARTIAL FURNITURE PLAN SCALE: 0" HALLWAY 11051 r SUPR. ! OFFICE "3 SO' 1 " LI NOTE FURNITURE EQUIPMENT INDICATED WILL BE PROVIDED INSTALLED BY THE TENANT, AND IS SHOWN FOR COORDINATION PURPOSES ONLY. WORK STATION AREA "I 11091 �I MAIL I CAB 1 Of'IE I !RED' I OFFICE I MAIL ROOM 114,1 1 CAB 1- FP I El E NORTH A R C H I T E C T S Church • Nickerson Jansen • Associates Cu REGISTERED 1 I AR HI CT I awl \ickers �TAiE N OF WACHINGP 0 w to a co H Q cv z IL U.1 • 13 • ict o o z o_ r 2 2 s cc cc z Z o � • 0 CD w ; z U. LU SHEET TITLE REFLECTED CEi_ENG _AN PARTIAL . F''sRN T I RE WN ary c i DATE 212E O! CNJA JOB NO. 5 1025 DRAWN M3 CHECKED DEJ SWEET A -2 SPLIT SYSTEM EVAPORATOR SCHEDULE MARK UNIT SERVES LOCATION FAN UNIT COOLING (1) ELECTRICAL (2) REMARKS (3) MANUFACTURER & MODEL NO. OPER. WEIGHT (LBS) NC. HP CFM (IN. ESP WG) COOLING CAP. (MBH) EVAPCRATOR FLA COIL V PH HZ WSA OPD FACE AREA (SQ. FT.) MAX FACE VEL (FPM) COIL ROWS TOTAL SENSIBLE CU -1 LAN ROOM # 106 ROOF ABOVE LAN RM 1 0.2 2200 4.1 2 11.4 208 1 60 EU -1 LAN ROOM # 106 LAN ROOM # 106 1 0.2 750 0.3 19.8 15.5 2.44 291 3 1.4 208 1 60 1.8 15 PROVIDE LIEBERT REMOTE MICROPROCESSOR CONTROL LIEBERT MMD18E 225 SPLIT SYSTEM CONDENSING UNIT SCHEDULE MARK UNIT SERVES LOCATION FAN ELECTRICAL (1) ,MANUFACTURER & MODEL NO. OPER. WEIGHT (Los) NO. HP CFM FACE AREA (SQ. FT.) COIL ROWS FLA V PH HZ WSA OPD CU -1 LAN ROOM # 106 ROOF ABOVE LAN RM 1 0.2 2200 4.1 2 11.4 208 1 60 13.9 20 LIEBERT PFCO20A 200 TO CONDENSING UNIT ON ROOF ABOVE - FIELD VERIFY EXACT LOCATION nLsR(� CEILING LINE ACCESS PANELS MINIMUM 3/4 TO CONDENSATE DRAIN (UNIT INTERNALLY TRAPPED) 30" MINIMUM ACCESS LAN ROOM SPLIT SYSTEM EVAPORATOR E CEILING MOUNT DETAIL M -1 M -1 SCALE:NONE 4 "PLUS DUCT HEIGHT OR 8 FOR TOP CONNECTION M -1 M -1 K I I �I�,JJJJJJJJJJJJJJJ TRANSFER GRILLE- ACOUSTICAL LINED BOOT NOTES: (1) FLA - FULL LOAD AMPS WSA - WIRE SIZE AMPS OPD - MAX. OVERCURRENT PROTECTION DEVICE 14 ° 0 3/8" 5/8" TRANSFER GRILLE DETAIL SCALE:NONE NOTES: (1) BASED ON 80'F DB, 50% RH, 2 - SPEED FAN AT HIGH SPEED (2) FLA - FULL LOAD AMPS WSA - WIRE SIZE AMPS OPD - MAX. OVERCURRENT PROTECTION DEVICE (3) PROVIDE LIEBERT PRECHARGED REFRIGERANT LINE SET SPRING AND NEOPRENE HANGER (TYP OF 4 RODS) THREADED ROD SUSPENDED FROM STRUCTURE ABOVE, 20- 1/2'0.C. (SUPPLIED BY CONTRACTOR) SEISMIC CABLES W /SWIVEL AT EACH END (TYP OF 4). ATTACH TO UNIT MOUNTING BRACKET W /NEOPRENE WASHERS. SEE ARCH. REFLECTED CEILING PLANS FOR SUSPENDED CEILING LAYOUT. AIR DISTRIBUTION PLENUM AT BOTTOM (SUPPLY AND RETURN) (TO HANG BELOW CEILING) GENERAL NOTES: 1. EXISTING CFM TO REMAIN THE SAME UNLESS OTHERWISE NOTED. FLAG NOTES MOVE EXISTING 4' -0 LINEAR SLOT DIFFUSER TO NEW LOCATION SHOWN. MOVE EXISTING DIFFUSER TO NEW LOCATION SHOWN. REBALANCE EXISTING LINEAR SLOT DIFFUSER TO NEW CFM SHOWN. ® REBALANCE EXISTING DIFFUSER TO NEW CFM SHOWN. MOVE EXISTING TRANSFER GRILLES AND FLEX DUCT TO NEW LOCATION SHOWN. © PROVIDE TWO (2) NEW EGGCRATE TRANSFER GRILLES AND DUCTWORK. GRILLES TO MATCH EXISTING. SEE DETAIL 2/M- 1/M -1. MOVE EXISTING THERMOSTAT TO NEW LOCATION SHOWN. MOUNT 0 60" AFF. ® MOVE EXISTING RETURN GRILLE TO NEW LOCATION SHOWN. PROVIDE CEILING MOUNT EVAPORATOR, SEE SCHEDULE AND DETAIL 1 /M- 1 /M -1. COORDINATE UNIT LOCATION AND CEILING WORK WITH ARCHITECTURAL. PROVIDE ROOFTOP MOUNTED CONDENSING UNIT. SEE SCHEDULE. MOUNT AND PIPE PER MANUFACTURERS RECOMMENDATIONS. COORDINATE PENETRATIONS WITH ARCHITECTURAL. SEAL ALL PENETRATIONS. D> PROVIDE LIEBERT REMOTE MICROPROCESSOR CONTROL. MOUNT B 60" AFF. N m 6 n O z w F- 00 0 LU PERMIT CEN CO N w H- 0 v) CO 00 00 0 OC w H- 00 0 N SHEET TITLE MECHANICAL PLAN, SCHEDULES, DETAILS DATE 8 -20 GNJA JOB NC. 01 MECHANICAL PLAN SCALE: 1/8"=1'--0 MI 20' S D. RC NOTKIN ENGINEERING, INC. 4th & Vine Bldg. 2601 4th Ave., Salle 420 Seattle, WA 98121 OFF: 206/448 -1911 FAX: 206/448 -9485 EXPIRES 2 -5 -2032 WWW.NOTKIN.COM CONTACT: BRIAN 0. GRIFFITH NEI #: 201051 EM OWAIO '-U A R C H I T E C T S i Church Nickerson Jansen Associates 877S Colby Su. ed7 ate.et t..we meal Ter.on ®ur 4aa vas - ieea n* *Pe 8e2-7B07 SHEET 4 CF 8 01 5 DD ELECTRICAL LEGEND SYM DESCRIPTION MANUFACTURER LAMP TYPE VOLTS VA /WATTS REMARKS FL2 RECESSED, LAY -IN, 2'54 ", 2 -LAMP RAPID START FLUORESCENT STATIC TROFFER. BALLAST: ELECTRONIC BUILDING STANDARD MATCH EXISTING 277 R5/61 AS INDICATED ON DRAWINGS REMODEL ELECTRICAL SYMBOL LEGEND SYMBOL EXAMPLE REMARKS HEAVY LINE WEIGHT STANDARD LINE WEIGHT WITH (E) CROSS HATCH LINE WORK NEW WORK EXISTING TO REMAIN UNLESS NOTED OTHERWISE ON DWG. (SEE BUBBLE NOTES) DEMOLITION AS INDICATED ON DRAWINGS - (E). 1 B -SHEET WHERE DETAIL TAKEN REFERENCE SYMBOL LEGEND SYMBOL DESCRIPTION REMARKS E DETAIL SYMBOL: AS INDICATED ON DRAWINGS A- IDENTIFYING NUMBER A OR AMP AF AIC ARCH AS AWG BLDG C CB CKT CU DWG ELEC EMT EXST FA FLA FLEX GALV GND HP J -BOX KV KVA KW LTG MAX MCB MCM OR KCM MECH ML NEUT 0 OR PH PNL PR RECPT REQ I RM SHT SW TEL TYP V VA XFMR B -SHEET WHERE DETAIL TAKEN C -SHEET WHERE DETAIL SHOWN LIGHTING RECESSED FIXTURE - ROUND EXIT FIXTURE - CEILING EXIT FIXTURE WITH DIRECTION ARROWS FIXTURE SYMBOL FLUORESCENT FIXTURE - LAY -IN TRACK LIGHTING SINGLE POLE TOGGLE THREE -WAY TOGGLE "WP " INDICATES WEATHERPROOF ENCLOSURE SINGLE POLE TOGGLE SHOWN WALL BOX DIMMER OUTLETS DUPLEX RECEPTACLE (NEMA 5 -20R) FOURPLEX RECEPTACLE (NEMA 5 -20R) GFCI DUPLEX RECEPTACLE (NEMA 5 -20R) ASTERISK INDICATES COUNTER HEIGHT OUTLET (DUPLEX RECEPTACLE SHOWN) JUNCTION BOX EQUIPMENT CONNECTION MOTOR CONNECTION - EXHAUST FAN SCHEDULED EQUIPMENT CONNECTION OR SYMBOL (INCLUDES FEEDER, DISCONNECT, STARTER, AND OTHER REQUIREMENTS AS SCHEDULED) SIGNAL TELECOMMUNICATIONS TERMINAL BOARD VOICE /DATA OUTLET FIRE ALARM SYMBOL FOR FIRE ALARM CONTROL PANEL MANUAL STATION SMOKE DETECTOR END OF LINE DEVICE REMOTE ALARM LIGHT DISTRIBUTION AND CIRCUITING PANELBOARD - FLUSH DRY TYPE TRANSFORMER GROUND ELECTRODE SYSTEM ENCLOSED CIRCUIT BREAKER CROSS LINES INDICATE NUMBER OF CONDUCTORS IF MORE THAN TWO WIRE CIRCUIT. LONG DENOTES NEUTRAL. DOT DENOTES GROUND. CONDUIT IS 1/2" AND CONDUCTOR IS #12 AWG UNLESS OTHERWISE NOTED OR SCHEDULED. HOMERUN INDOOR SERVICE POLE WIRING CONCEALED IN CEILING OR WALL ' FLEXIBLE WIRING CONNECTION SECTION SYMBOL: AS INDICATED ON DRAWINGS A- IDENTIFYING NUMBER B -SHEET WHERE DETAIL TAKEN C -SHEET WHERE DETAIL SHOWN BUBBLE NOTE TAG SYMBOL: #- IDENTIFYING NUMBER II ABBREVIATIONS LIST ELECTRICAL LEGEND ABBREV DESCRIPTION II SYMBOL DESCRIPTION A OR AMP AF AIC ARCH AS AWG BLDG C CB CKT CU DWG ELEC EMT EXST FA FLA FLEX GALV GND HP J -BOX KV KVA KW LTG MAX MCB MCM OR KCM MECH ML NEUT 0 OR PH PNL PR RECPT REQ I RM SHT SW TEL TYP V VA XFMR AMPERES AMP FUSE AMPERE INTERRUPTING CAPCITY ARCHITECTURAL. AMP SWITCH AMERICAN WIRE GAUGE BUILDING CONDUIT CIRCUIT BREAKER CIRCUIT COPPER DRAWING ELECTRIC ELECTRICAL METALLIC TUBING EXISTING FIRE ALARM FULL LOAD AMPS FLEXIBLE CONDUIT GALVANIZED GROUND HORSEPOWER JUNCTION BOX KILOVOLTS KILOVOLT AMPERES KILOWATTS LIGHTING MAXIMUM MAIN CIRCUIT BREAKER THOUSAND CIRCULAR MILS MECHANICAL MAIN LUG NEUTRAL PHASE PANEL PAIR RECEPTACLE REQUIRED ROOM SHEET SWITCH TELEPHONE TYPICAL VOLTS VOLT AMPERES TRANSFORMER LIGHTING RECESSED FIXTURE - ROUND EXIT FIXTURE - CEILING EXIT FIXTURE WITH DIRECTION ARROWS FIXTURE SYMBOL FLUORESCENT FIXTURE - LAY -IN TRACK LIGHTING SINGLE POLE TOGGLE THREE -WAY TOGGLE "WP " INDICATES WEATHERPROOF ENCLOSURE SINGLE POLE TOGGLE SHOWN WALL BOX DIMMER OUTLETS DUPLEX RECEPTACLE (NEMA 5 -20R) FOURPLEX RECEPTACLE (NEMA 5 -20R) GFCI DUPLEX RECEPTACLE (NEMA 5 -20R) ASTERISK INDICATES COUNTER HEIGHT OUTLET (DUPLEX RECEPTACLE SHOWN) JUNCTION BOX EQUIPMENT CONNECTION MOTOR CONNECTION - EXHAUST FAN SCHEDULED EQUIPMENT CONNECTION OR SYMBOL (INCLUDES FEEDER, DISCONNECT, STARTER, AND OTHER REQUIREMENTS AS SCHEDULED) SIGNAL TELECOMMUNICATIONS TERMINAL BOARD VOICE /DATA OUTLET FIRE ALARM SYMBOL FOR FIRE ALARM CONTROL PANEL MANUAL STATION SMOKE DETECTOR END OF LINE DEVICE REMOTE ALARM LIGHT DISTRIBUTION AND CIRCUITING PANELBOARD - FLUSH DRY TYPE TRANSFORMER GROUND ELECTRODE SYSTEM ENCLOSED CIRCUIT BREAKER CROSS LINES INDICATE NUMBER OF CONDUCTORS IF MORE THAN TWO WIRE CIRCUIT. LONG DENOTES NEUTRAL. DOT DENOTES GROUND. CONDUIT IS 1/2" AND CONDUCTOR IS #12 AWG UNLESS OTHERWISE NOTED OR SCHEDULED. HOMERUN INDOOR SERVICE POLE WIRING CONCEALED IN CEILING OR WALL ' FLEXIBLE WIRING CONNECTION � cr 0040 oa)d0 'I• ¢I E t A R C H I T E C T S , Church • \ickerson Jansen - Associates KEY PLAN SCALE: 1" = 40' -O" CONSTRUCTION AREA ELECTRICAL CONSTRUCTION NOTES 1. REGULATORY REQUIREMENTS NATIONAL ELECTRICAL CODE, STATE AND LOCAL ELECTRICAL AND BUILDING CODES, LOCAL UTILITY CO. REQUIREMENTS. OBTAIN AND PAY FOR REQUIRED PERMITS. 2. SUBMITTALS SUBMIT TO ARCHITECT /ENGINEER FOR APPROVAL PRODUCT DATA ON LIGHT FIXTURES AND DISTRIBUTION EQUIPMENT. 3. RACEWAYS EMT FOR DRY AND DAMP LOCATIONS; FLEXIBLE CONDUIT FOR FINAL CONNECTIONS TO RECESSED LIGHT FIXTURES AND EQUIPMENT SUBJECT TO VIBRATION OR MOVEMENT. FLEXIBLE CONDUIT MAY BE USED WHERE CONCEALED IN WALLS. 4. CONDUCTORS COPPER BUILDING WIRE, TYPE THWN. 5. DISTRIBUTION EQUIPMENT GENERAL DUTY EQUIPMENT MANUFACTURED BY SQUARE D, GENERAL ELECTRIC. WESTINGHOUSE, I.T.E. OR CUTLER HAMMER. FULL SIZE (1" /POLE) AND MULTIPOLE COMMON TRIP CIRCUIT BREAKERS ONLY. PROVIDE PANEL COVERS WITH FLUSH LOCKING DOOR KEYED ALIKE. WHERE INDICATED ON DRAWINGS, AIC RATING IS THE RMS SYMMETRICAL INTEGRATED EQUIPMENT SHORT CIRCUIT RATING OF THE COMPLETE ASSEMBLY. 6. FUSING UL CLASS RK1 EXCEPT CLASS RK5 WITH TIME DELAY FOR MOTOR LOADS. 7. WRING DEVICES COMMERCIAL GRADE VERTICALLY MOUNTED WITH HIGH IMPACT THERMOPLASTIC MATCHING DEVICE PLATE; IVORY COLOR UNLESS OTHERWISE DIRECTED. 8. EQUIPMENT GROUNDING CONDUCTOR PROVIDE SEPARATE INSULATED GREEN EQUIPMENT GROUNDING CONDUCTOR IN FEEDERS AND IN BRANCH CIRCUITS TO PLUG -IN OUTLETS. EXCEPTION: CONDUIT MAY SERVE AS EQUIPMENT GROUNDING MEANS WHERE CONDUIT IS RIGID STEEL 9. MOUNTING HEIGHTS ALL HEIGHTS MEASURED FROM FINISH FLOOR TO CENTERLINE OF DEVICE: WALL SWITCHES RECEPTACLE OUTLET SIGNAL OUTLET 48" 18" 18" 10. CIRCUIT DIRECTORY PROVIDE TYPEWRITTEN INDEX OF CIRCUITS LOCATED ON INSIDE DOOR OF EACH PANEL, INCLUDING EXISTING PANELS IN WHICH CIRCUITS ARE CHANGED. IDENTIFY LOAD TYPE AND LOCATION USING FINAL ROOM NAMES OR NUMBERS VERIFIED BY OWNER. 11. LIGHTING FIXTURES PROVIDE FIXTURES COMPLETE WITH LAMPS, MOUNTING HARDWARE. PROVIDE REQUIRED AUXILIARY SUPPORTS. 12. TELECOMMUNICATION PATHWAY TERMINAL: 48" X 96" X 3/4" PAINTED PLYWOOD. VOICE /DATA OUTLETS: RECESSED 4 X 2 -1/2 BOX, SINGLE GANG RING, BLANK DEVICE PLATE, 3/4" CONDUIT HOMERUN TO ACCESSIBLE CEILING. 13. EQUIPMENT CONNECTIONS PROVIDE POWER CONNECTIONS TO ALL EQUIPMENT BEING FURNISHED OR INSTALLED UNDER THE CONTRACT. PROVIDE PIGTAIL AND PLUG WHERE REQUIRED FOR PLUG -IN CONNECTIONS. 14. LIGHTING CIRCUITS INDICATE CIRCUITING AND WIRING LAYOUT ON RECORD DRAWINGS. REFER TO PANEL SCHEDULES FOR GENERAL AND DEDICATED LIGHTING CIRCUITS. MAXIMUM LOADING SHALL BE 3600 VA PER PHASE AT 480/277 VOLTS. 15. RECEPTACLE CIRCUITS INDICATE CIRCUITING AND WIRING LAYOUT ON RECORD DRAWINGS. REFER TO PANEL SCHEDULES FOR GENERAL USE AND DEDICATED CIRCUITS. MAXIMUM 6 OUTLETS PER CIRCUIT UNLESS OTHERWISE INDICATED. 16. TELECOMMUNICATIONS PREWIRE VOICE /DATA PRE -WIRE IS NOT IN CONTRACT. COORDINATE WITH OWNER TO ARRANGE PRE -WIRE BY OTHERS PRIOR TO COVER. 17. FIRE ALARM SYSTEM - BIDDER DESIGN EXTEND EXISTING RADIONICS BRAND FIRE ALARM SYSTEM INTO .INDIVIDUAL OFFICE SPACES IN THE TENANT IMPROVEMENT AREA, CONFORMING WITH MINIMUM REQUIREMENTS OF LOCAL AUTHORITY HAVING JURISDICTION (AHJ). EXTEND EXISTING TENANT SPACE SMOKE DETECTOR ZONE INTO INDIVIDUAL OFFICES, EXTEND HORN /STROBE LOOP FROM BUILDING CORRIDOR INTO TENANT SPACE. MODIFY /UPGRADE EXISTING CONTROL AND BATTERIES TO ACCOMMODATE NEW WORK. PROVIDE NEW INITIATING CIRCUITS, SIGNALING CIRCUITS, AND AUXILIARY RELAYS AS REQUIRED. EXPANDER PANEL(S) MAY BE ADDED TO ACCOMMODATE NEW SIGNALING DEVICES. GENERAL ELECTRICAL NOTES: 1. SEE ARCHITECTURAL PLANS FOR LOCATION OF FIRE RATED CONSTRUCTION. 2. BRANCH CIRCUIT NOTES: A. ONLY BRANCH CIRCUIT HOMERUNS INDICATE CONDUCTOR COUNT IF MORE THAN TWO WIRE CIRCUIT PLUS GROUND. CONTINUE WIRE COUNT TO OUTLETS AS REQUIRED TO PROVIDE INDICATED PHASE, NEUTRAL, AND EQUIPMENT GROUND CONDUCTORS PER CODE BASED ON CIRCUIT DESIGNATIONS INDICATED. B. FOR SWITCHED OUTLETS, PROVIDE ADDITIONAL CONDUCTOR COUNT REQUIRED FOR SWITCH LEGS TO ACCOMMODATE SWITCH CONTROL INDICATED. MAINTAIN UNSWITCHED LEG IN LIGHTING BRANCH CIRCUITS TO EXIT, LIGHTING SHOWN. C. NEUTRAL CONDUCTOR SIZE FOR MULTI -WIRE BRANCH CIRCUITS SERVING COMPUTER PURPOSE OUTLETS SHALL BE #10 AWG MINIMUM. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR COMPUTER PURPOSE CIRCUITS WHERE COMPUTER PURPOSE AND GENERAL PURPOSE CIRCUITS SHARE THE SAME CONDUIT. 3. MINIMUM CONDUIT SIZE FOR HOMERUNS SHALL BE 3/4 INCH. 4. REFER TO ARCHITECTURAL PLANS FOR LIGHT FIXTURE LOCATIONS. REFER TO REFLECTED CEILING PLANS, INTERIOR ELEVATIONS, ROOM SECTIONS, AND DETAILS SHOWN ON ARCHITECTURAL CONTRACT DOCUMENTS PRIOR TO ROUGH -IN. REPORT CONFLICTS TO ARCHITECT /ENGINEER FOR RESOLUTION. 5. REFER TO ARCHITECTURAL ELEVATIONS FOR LOCATION AND MOUNTING HEIGHT OF WIRING DEVICES. REPORT CONFLICTS TO ARCHITECT /ENGINEER FOR RESOLUTION. 6. VERIFY BACK BOX REQUIREMENTS OF EQUIPMENT FURNISHED UNDER OTHER THAN DIVISION 16 SECTIONS AND EQUIPMENT FURNISHED BY OWNER. 7. MAINTAIN AT PROJECT SITE ONE SET OF CLEAN, DRY, AND LEGIBLE RED -LINED RECORD DRAWINGS FOR SUBMITTAL AT CONTRACT CLOSE -OUT. INDICATE ELECTRICAL CHANGES, PIJLL Sc JUNCTION BOXES ADDED DURING CONSTRUCTION. AND ACTUAL DIMENSIONED LOCATION OF EACH UNOERGRCUNU CONDUIT ON RECORD DRAWINGS. RECORD INFORMATION CONCURRENTLY WITH CONSTRUCTION PROGRESS. REMODEL ELECTRICAL NOTES: 1. FIELD VERIFY EXISTING CIRCUITS AS REQUIRED TO PERFORM WORK. USE AVAILABLE SPARE BREAKERS TO RECONNECT EXISTING CIRCUITS NOT SHOWN. REVISE CIRCUIT DIRECTORIES AND NOTE CHANGES ON RECORD DRAWINGS. 2. IT IS ASSUMED THAT EXISTING WIRING , ABOVE CEILINGS ARE NOT SUPPORTED PER CODE. INCLUDE NEW CONDUIT SUPPORTS FOR EXISTING WIRING ACCESSED DURING CONSTRUCTION. CAREFULLY REMOVE, STORE, AND REINSTALL EXISTING REMOVABLE CEILING TILES AND EXISTING LIGHT FIXTURES WHERE ACCESS TO PERFORM WORK IS REQUIRED. 3. REMOVE ABANDONED WIRE TO SOURCE OF SUPPLY. REMOVE ABANDONED CONDUIT WHERE EXPOSED AND WITHIN ACCESSIBLE CEILING AND OPEN WALL SPACES. CUT CONDUIT FLUSH WITH WALLS AND FLOORS; PATCH SURFACES IN FINISHED SPACES. 4. DISCONNECT ABANDONED OUTLETS AND REMOVE DEVICES. PROVIDE BLANK COVERS FOR ABANDONED OUTLET BOXES IN WALLS TO REMAIN. 5. CUT -IN FLUSH OUTLET BOXES AND FISH CONDUIT IN EXISTING CONSTRUCTION OF REMODELED AREAS. FLEXIBLE CONDUIT IS APPROVED WHERE FISHING OF CONDUIT IS REQUIRED. 6. REPLACE, MODIFY OR EXTEND EXISTING OUTLET BOXES TO MEET VOLUME REQUIREMENTS. CUT SURFACES AS REQUIRED TO REPLACE (OR MODIFY) EXISTING OUTLET BOXES AND TO INSTALL SUPPORTS FOR NEW BOXES AND FIXTURES AND PATCH TO MATCH ADJACENT SURFACE. LIGHTING CONTROL NOTES: 1. THE FOLLOWING NOTES REFERENBE SECTIONS OF THE WASHINGTON STATE ENERGY CODE. 2. PROVIDE EACH ROOM WITH LOCAL LIGHTING CONTROL AT THE ENTRY /EXIT DOOR UNLESS OTHERWISE NOTED AS AN EXCEPTION (SECTION 1513.1) 3. THE MAXIMUM LIGHTING LOAD CONTROLLED BY A SINGLE SWITCH OR AUTOMATIC CONTROL SHALL NOT EXCEED 16 AMPS. (SECTION 1513.2) 4. PROVIDE SEPARATE CONTROL OF DAYLIGHTED ZONES INDEPENDENT OF GENERAL AREA LIGHTING. INDICATES BOUNDARY OF DAYLIGHTED ZONES. (SECTION 1513.3) bOV2 '9 XX; OH wets: 6/27/02 F Ili H- L- - CITY (I- i. ,UILA. C F- L,1 Cr) Q C� DC ID N Lti SHE "FT_ __c-=_CC T NOTES H- Pr, D4T S-20 -01 C: !„- °_ NO. 0225 GµF_< ,_5 SHEET SHEET S OF 5 LA R C H I T E C T J Church • !Nickerson Jansen •Associates W iG.- T ING DEMOLITION (E) (E) (E) (E) SALES (E) CRS D157 (E) MGR SALES U G1 r: V, 0 :Erlo RM BL2 -39 0 0 0 (E) SvC E) r l FE (E) (E) (E) (E) TRACK LIGHTS NORTH (E) (E) SAG- CRS (E) (E) (E}. (E) i (E) (E) RECEPTION O 11 I ' (E) (E) (E) STOCK R`1 \ 1/1 (E) TELT. ROOM is ( E ) MACHINE LOCK -UP (E) LTG 277V, PNL 82. TYPICAL GENERAL NOTES (E) L13RAR" (E) POWER 4 SIGNAL DEMOLITION SCALE: vs = r -u:: /_ (E) (E) (E) TECHNICIANS BL2 -24 (E) (E) I E)IG(E)IG (E),, 1. REMOVE & RE- INSTALL LAY -IN FIXTURES AS REQUIRED FOR CEILING GRID MODIFICATIONS REQUIRED BY INSTALLATION OF FULL - HEIGHT WALLS. RELOCATE J -BOXES ABOVE T -BAR CEILING AS REQUIRED FOR INSTALLATION OF FULL - HEIGHT WALLS. ( F) BL2 -26 2. SAVE ALL LAY -IN FIXTURES SHOWN TO BE REMOVED, RE- INSTALL FIXTURES AT LOCATIONS SHOWN ON LIGHTING PLAN. 3. CIRCUIT NUMBERS SHOWN ON DRAWING ARE BASED ON PANEL SCHEDULE DESCRIPTIONS. VERIFY CIRCUIT NUMBER BEFORE BEGINNING WORK. 0 NORTI -1 (E) (E) (E) K (E) CR5 SVC. IC- -R HALLW4Y E=.4 gl BL2 -27 54 o BL2 -25 (E) - -�' A.* B=P PEND RN 3� BL2 -37 d' zC- CYS (E) F (E) LUNCH L2 -30,32 BL2 -34 (E) EF (E) STOCK ■ RECEPTION (E) (E) TE_E. ROOM f ` V +48" BLI2 -38 (E) (E) BL2 -31 (F) I 0'i. _O K (F) MUCH IN=_ LOCK -UP CL =RICA! P -41 (E) (E) A ) (E) (E) (E) BL2 -35 (E) F EOL DIST MGR (E) q5 OF T16.1" SEP - 7 2 401 5 00 7G BUBBLE NOTES 0 REMOVE OUTLET, MAINTAIN J -BOX FOR NEW OFFICE FURNITURE. ® REPLACE EXISTING RECEPTACLE WITH GFCI RECEPTACLE. O3 REMOVE TWO DUPLEX RECEPTACLES, PROVIDE TWO GFCI RECEPTACLES. 0 CONNECT LIGHT FIXTURES IN THIS ROOM TO LIGHTING SWITCHLEG IN ROOM TO NORTH. O5 RELOCATE LIGHT SWITCH. ©RELOCATE SMOKE', DETECTOR. (9 REMOVE EXISTING LAY -IN FIXTURE CUBE LENS, PROVIDE PRISMATIC ACRYLIC LENS TO MATCH EXISTING. LIGHT. SWITCHES PROVIDE 2 -LEVEE SWITCHING FOR RECEPTION, CLERICAL AND' HALLWAY. 0 REMOVE AND RE- INSTALL FIXTURES, AND RELOCATE J-BOXES, AS REOUIRED FOR CEILING GRID MODIFICATIONS AND EXTENSION OF EXISTING WALL TO STRUCTURAL CEILING. DATE 77 CPU L L _u CA 5i-EET TITS= DEMIOL ION PLANS `i'.'^ ✓ILA PERM : TT IJI TR CtiJA JOB NO. 01Q25 DRAWN 5AT CHECKED JA SHEET ------ ._.- -- -- 5R' RY 1011 - � (E) (E) (E) (E) 'CONFERENCE ROOT 11021 SUPERVISOR OFFICE 1 — BREAK 1103 1 —) ROOM i „ : (E) •0f ( (E) • r . (E) (E) j \ \ (E) (E) (E) (E 13 i nr irr rrrrrrr rrrrrrr«� (`-4— �� !ALL WAY 11051 (E) (E) PNL 5 � (E) 1! SUPR 1 1 FLAN (E) (E) (E) (E) LAN ROOM 11061 (E) uTi I/ I VI RK STATION AREA .2 1 113 I (E) (E) OFFICE 0 () 1081 (E) Q SUPERVISOR OFFICE .2 11071 © (E) (E)' Q I / I u rr— WORK STATION E AREA `3 E 11c _ E (E) (E) No 11 I/ (E) (E) (E) 'WORK 'STATION AREA '1 110°' (E) I/I (E) (E) (E) 1 (E) (E) (E) (E) (E) (E) I/I ICI (E) (E) UJ (E) NO I (E) (E) (E) S 1 PERVI R ( (E) (E) ©r DAYLIGHTED LIGHTING ZONE RK STATION 111F, 1 CD CD u r =-1,. FED ■ON I;0i NORT- (E) (E) MAIL ROOM 11151 ❑ (E) — SUPERVISOR OFF . (E) (E) (E) (E) (E) — MRANCI- OFFICE [Al 1 SCALE: /S = - , ' FROWE I\ ON ROOF 0 NORTI -! (E ROOM 11061 S-18.20,22,24 S- 26.28,30 1/2 "C, 4 #12, #12 >F:E 5 -14,16 `E) (E) . (E) CONFERENCE ROOM 11021 BL2 -24 IG (E) -16 (E) (E) SUPERVISOR OUR ,-- (E) .:I,,.0 (E) (U) (012(E) ((E - ( BL2--34 (E) I IIII (`) �(E) HALLW 82- 26, 28,30 _(E) 105 PNL S� �/ K (E) I i ',(E) (E) v l� (E) ( ► C ',. BL2 - i. 4 (E) (E) ' OFFICE ° 114 ;I', C11 K (E) ECEPTION 1 117 S-15,17 BL2 -39, 41 5- -10,12 WORK STATION ORES '2 113 I S - 6.8 Thhl (E) (E) ,BREAK ROOM 11041 WORK STATION AREA `I SUPERVISOR OFFICE '5 11201 (E) MAIL ROOM 1 115 1 2sq EO (E ❑ BUBBLE NOTES 0 CONNECT NEW LIGHTING TO EXISTING HALLWAY LIGHTING CIRCUIT. ® EXISTING OUTLET BOX. PROVIDE HOMERUN TO NEW PANEL. OF O 0 ® VERIFY EXISTING CIRCUIT NUMBERS. REVISE WIRING AS REQUIRED TO CONNECT EXISTING OUTLETS TO THE CORRECT CIRCUIT NUMBER. / „ 2DO1 ® PROVIDE NEW GFCI RECEPTACLES AT EXISTING OUTLETS. NOTED ® PROVIDE J -BOX AT +54" & CONDUIT TO ACCESSIBLE CEILING FOR MAGNETIC CARD READER. BY OTHERS: © COREDRILL CONCRETE WALL. ® SECURITY SYSTEM MAGNETIC DOOR CONTACTS BY OTHERS. ® NOT USED. 9® REVISE WIRING TO PROVIDE LIBRARY SWITCHING SEPERATE FROM CONFERENCE ROOM. 10 VERIFY EXACT LAN ROOM EQUIPMENT LOCATIONS WITH OWNER. LOCATE OUTLETS AS DIRECTED. 11 CONNECT LIGHT SWITCHES TO EXISTING LIGHTING 12 RE- INSTALL EXISTING FIXTURE AT NEW LOCATION.', 13..ONE SWITCH CONTROLS CENTER LAMP, THE OTHER SWITCH CONTROLS THE TWO OUTSIDE LAMPS ON EACH FIXTURE. 14 CONNECT! TO EXISTING UNSWITCHED LIGHTING CIRCUIT CONDUCTOR. SL°ER' /IS OFF!CE R C H i T E C T� Church • Nickerson Jansen • Associates :>z: Co S EUL 0) eXPrxFS: 1/27 /02 J — E l o1 0 !SHEET -1T E LIGHTING • POWER PLANS Q PERMIT CENTER �GLIC - n. C E: 5-20-01 CN .,C5 NO. 0,'025 DRAWN �- C NECKED EET' EXISTING THREE PHASE PANEL SCHEDULE [ EXISTING THREE PHASE PANEL SCHEDULE N0. B2 (EXISTING PANEL) 480 /277 VOLT -PHASE 4 -WIRE LOCATION: BLDG CORRIDOR BUS: 225 AMPS MAN: LUG ENCLOSURE: FLUSH , SIEMENS A.I.C. SSEMBLY WORK STNS, AREA #1, NE WORK STNS, AREA #1, NE NO. BL2 (EXISTING PANEL) 208/120 VOLT 3 -PHASE 4-WRE LOCATION: BLDG CORRIDOR BUS: 200 AMPS MAIN: 200A MCB ENCLOSURE: FLUSH SIEMENS 15000 A.I.C. ASSEMBLY DESCRIPTION VA BKR CKT PHASE CKT BKR V DESCRIPTION NO. A C N0. MOP DESCRIPTION VA BKR CKT PHASE CKT BKR VA DESCRIPTION NO. A C NO. LTG- UNICLOBE UNKNOWN POWER TEMP LTG LTG - UNIGLOBE UNKNOWN TEMP LTG TRI -ARC LTG SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE AC -8 AC -2 4150 554 4150 4150 5540 4150 41 0 13 0 13 0 13 0 38 0 38 0 38 0 20/I 20/1 20/1 20/1 20/1 20/1 20/1 20/3 60/3 WORK STNS, AREA #2, NE WORK SONS, AREA #2, NE 7050 8440 7050 7050 5540 4150 4150 0 0 0 0 0 0 0 0 4360 4360 4360 7720 7720 7720 �a m — __ Mme <, 20/1 20/1 20/1 20/1 40/3 70/3 29 0 29 0 29 0 29 0 3040 3040 3040 3860 3860 3860 LTG - DICTAPHONE LTG - DICTAPHONE LTG - DICTAPHONE LTG - DICTAPHONE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE AC -1 AC -6 20/1 RECPT - BY PNL OPEN OFFICE 103 FLR RECPT TEL RM 109, 110, 111, RECPT OPEN OFFICE 101 -103 RECPT 103 OPEN OFFICE 106 RECPT 108 0TS SUB PANEL TRI -ARC SUB PANEL CONTROL TRANS HEAT SALES POWER POLE /DEMO SALES SPARE CLERICAL/MAIL, COPY DED COMPUTER DIS. MGR /CLERICAL DED. DEMO LTS DEMO DED CLERICAL REMARKS - 20/1 20/1 20/1 20/1 20/1 90/3 90/3 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 540 20/1 ....:........i 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 RECPT - ROOF EXH FAN BATH LT FAN & RECPT ACCOUNTING FLOOR RECPT ACCOUNTING FLOOR RECPT ACCOUNTING FLOOR RECPT ASSEMBLY RECPT (D) LUNCH & ASSEMBLY RECPT LUNCH RM (0) RECPT DISHWASHER HALL LTS TECHNICIANS TECHNICIANS/PWR POLE SALES MGR /CRS RM DED. MICRO LUNCH RM. COFFEE LUNCH RN STOCK RN FR HER DED TEL RM SPARE SPARE REMARKS: CON ECTE LOA5 30330 26060 23280 CALCULATED LOAD (KVA): VA: 79.67 125% CONTINUOUS LOAD 40.44 A PS: 95.87 50% RECEPT OVER 10KVA 0.00 25% LARGEST MOTOR 2.90 OTHER 0.00 REMAINDER 47.32 TOTAL HAS 90.65 TOTAL AMPS: 109.09 REVISED 20/1 RE 2160 20/1 REVISED THREE PHASE PANEL SCHEDULE ' REVISED THREE PHASE PANEL SCHEDULE NO. BL2 (EXISTING. PANEL) 208,120 VOLT 3 -PHASE 4 -WIRE LOCATION: BLDG CORRIDOR BUS: 200 AMPS MAIN: 200A MCB ENCLOSURE: FLUSH SIEMENS 15000 A.I.C. ASSEMBLY NO. B2 (EXISTING PANEL) 480 /277 VOLT -PHASE 4-WRE LOCATION: BLDG CORRIDOR BUS: 225 AMPS MAIN: LUG ENCLOSURE: FLUSH , SIEMENS VERIFY A.I.C. AS EMBLY DESCRIPTION VA BKR CKT PHASE CKT BKR V DESCRIPTION NO. A B C NO. KVA DESCRIPTION VA BKR CKT PHASE CKT BKR VA DESCRIPTION NO. A B C NO. LTG- UNIGLOBE UNKNOWN POWER TEMP LTG LTG - UNIGLOBE UNKNOWN TEMP LTG IRI -ARC LTG SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE AC -8 AC -2 4150 5540 4150 4150 55 0 41 0 41 0 13 0 13 0 13 0 3860 3860 3860 20/1 20/1 20/I 20/1 20/1 20/1 20/1 20/3 60/3 WORK STNS, AREA #1, S 7050 8440 7050 7050 5540 4150 4 150 0 0 0 0 0 6270 8930 7500 4360 4360 4360 7720 7720 7720 20/1 20/1 20/1 20/1 20/1 60/3 40/3 70/3 29 0 29 0 29 0 29 0 82 0 8930 7500 3040 3040 3040 3860 3860 3860 LTG - DCAA LTG - DCAA LTG - DCAA LTG - OCAA SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE XFMR - DCAA (1) AC -1 AC -6 1080 RECPT - BY PNL OPEN OFFICE 103 FOR RECPT TEL RM 109, 110, 111, RECPT OPEN OFFICE 101 -103 RECPT 103 OPEN OFFICE 106 RECPT 108 0TS SUB PANEL IRI -ARC SUB PANEL CONTROL TRANS HEAT SPARE SPARE SPARE CLERICAL /MAIL, COPY SPARE RECPT - RECPTN, SUP OFF #4 SPARE RECPT - RECPTN, SUP OFF #5 SPARE COPIER SHREDDER 20/1 20/1 20/1 20/1 20/1 90/3 90/3 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 ��^ __� ���� MM�� ___ �v� � �n�� 20/1 20/1 1080 1000 RECPT - ROOF EXH FAN BATH LT FAN & RECPT ACCOUNTING FLOOR RECPT ACCOUNTING FLOOR RECPT ACCOUNTING FLOOR RECPT ASSEMBLY RECPT (D) LUNCH & ASSEMBLY RECPT LUNCH RM (D) RECPT DISHWASHER HALL LTS TECHNICIANS CONE POWER POLES RECPT -SUP OFF #2 DED. MICRO LUNCH RM. COFFEE LUNCH RN STOCK RM WAR HTR SPARE SPARE SPARE REMARKS: LI) PROVIDE NEW GRCUIT BREAKER CONNECTED LOAD: 38600 34990 30780 CALCULATED KVA: 104.37 125% CONTINUOUS AMPS 125.60 50% RECEPT 25% LARGEST OTHER REMAINDER TOTAL KVA: TOTAL AMPS: LOAD (KVA): LOAD 40.44 OVER 10KVA 0.00 MOTOR 2.90 0.00 7202 115.35 138.81 REMARKS: LOAD JUSTIFICATION: SIX CIRCUITS REMOVED, NO LOAD ADDED. THREE PHASE SCHEDULE NO. S (NEW PANEL) 208/120 VOLT 3 -PHASE 4 -WIRE LOCATION: DCAA HALLWAY NO. 2 BUS: 125 AMPS MAIN: LUG ENCLOSURE: FLUSH 10,000 A.I.C. ASSEMBLY DESCRIPTION VA BKR CKT PHASE CKT BKR VA DESCRIPTION NO. A C NO. WORK STNS, AREA #1, NE WORK STNS, AREA #1, NE 1080 1080 20/1 20/1 MOP 2160 2160 �a�m ���� 20/1 20/1 1080 1080 WORK STNS, AREA #2, NE WORK SONS, AREA #2, NE WORK STNS, AREA #1, NE 1080 20/1 CONDENSING UNIT AIR CONDITIONING 2160 20/1 1080 WORK STNS, AREA 41, SE WORK SINS, AREA #1, NW 540 20/1 125% 1620 20/1 1080 WORK STNS AREA #1, SE WORK SONS, AREA #1, S 1080 20/1 2160 20/1 1080 WORK SONS, AREA H1, W WORK SINS, AREA #1, S 1080 20/1 KVA 2160 20/1 1080 WORK STNS. AREA #3, W WORK STNS, AREA #1, S 1080 20/1 2160 20/1 1080 WORK STNS, AREA #3, N COPIER SHREDDER 1200 10 0 20/1 20/1 2280 2000 20/1 20/1 1080 1000 WORK STNS, AREA #3, S RECPT - LAN RM SERVER SPARE 20/1 1000 20/1 1000 RECPT - LAN RM ACCESSORIES SPARE 20/1 1000 20/1 1000 RECPT - LAN RM TEST EQUIP SPACE 1000 20/1 1000 RECPT - LAN RM TEL UPS SPACE 1330 20/2 1330 A/C - LAN RM, ROOF SPACE 1330 1330 SPACE 180 20/1 180 RECPT - ROOF REMARKS: CONNECTED KVA: LOAD: 8270 8930 7500 CALCULATED 24.70 125% CONTINUOUS LOAD (KVA): LOAD 0.00 AMPS: 68.61 50% RECEPT OVER 1OKRA 0.00 25% LARGEST MOTOR 0.00 OTHER 0.00 REMAINDER 24.70 TOTAL KVA: 24.70 TOTAL AMPS: 68.61 EQUIPMENT CONNECTION SCHEDULE SYMBOL DESCRIPTION LOCATION SIZE FLA MCA MOP VOLT /PH PANEL FEEDER (NOTE 1) CONNECTION (NOTE 2) DISCONNECT CONTROL REMARKS CU III, CONDENSING UNIT AIR CONDITIONING ROOF OVER LAN LAN ROOM 2.37KW 0.3 KW 11.4 1.4 13.9 1.8 20 15 208/1 208/1 S S 125% 30A SW, 20 AF 30A SW, 15 AF Adjusted Demand LOAD CALCULATION - EXISTING METER 480/2070 - 3PH Description Remarks Utility Metered 12 Month Peak Demand 266.0 KW Power Factor 0.95 12 Month Peak KVA 280.0 KVA Demand Factor 125% NEC 230 -25 Adjusted Demand 350.1 KVA New Load Added - Panel S 24.7 KVA Total Load 375.2 KVA 452.0 AMPS NEW EXISTING (2) 5 "C, 4 #750 AL� TO PUGET POWER VAULT EXISTING MAIN POWER ROOM 480/2770 30 4W 800A SW80 225 22_5/3 225 225/3 o Th : o �2 1 /2 "C, 4 #300 KCM AL 1/4 "C, 3 #2 NEW C.B. BLDG CORRIDOR PAL 82 PNL BL2 SIEMENS SIEMENS 480V/277V 30 208V/120V 30 225A ML 200A MCB NEW 1 "C, 3 #4, #10 GND PNL 480: 208Y/120V 30 4W 75KVA ","--2 "C, 4 #3/0 CU ONE —LINE DIAGRAM NO SCALE GENERAL: 1)61 259 REFERENCED: EXISTING 1 "C STUBBED TO ACCESIBLE CEILING SPACE DCAA SPACE NEW TRANSFORMER 480 A : 208Y/1 20V 30 45 KVA NEW 2 "C, 4 #1 /0. #6 GND A. OUTLETS, DISCONNECTS, CONTROLLERS, AND EQUIPMENT CONNECTIONS FOR ROOF TOP AND OTHER OUTDOOR. EQUIPMENT SHALL BE WEATHER PROOF. B. LOCATION OF OUTLETS, DISCONNECTS, CONTROLLERS, AND EQUIPMENT CONNECTIONS ARE DIAGRAMMATIC AND TO BE LOCATED IN FIELD BY THE CONTRACTOR AS APPROVED BY THE ENGINEER. C. COORDINATE WITH THE INSTALLING CONTRACTORS TO ENSURE NEC REQUIRED ACCESS TO DISCONNECTS IS PROVIDED FOR EACH PIECE OF EQUIPMENT. NEW LOAD CENTER 120/208V 30 4W 125A M.L. NEW 2 "C, 4 #1/0, #6 GND 1. PROVIDE HOMERUN TO PANEL INDICATED, 1/2 INCH CONDUIT WITH #12 CONDUCTOR FOR EACH PHASE AND NEUTRAL PLUS GROUND UNLESS OTHERWISE INDICATED. 2. ALL EQUIPMENT DIRECT WIRED UNLESS OTHERWISE NOTED. A R C H I T E C T SI Church • Nickerson Jansen • Associates I menus /27/021 - 7 S I -IFPT A !)= A PEiil01T CENTER T LIE g-20-01 JOS NT. TW WN SLY CHECKET jas SLIEST